Sie sind auf Seite 1von 1

FOUNDATION PLAN NOTES

1.
2.
3.

4.

5.

6.
7.

EXISTING CONSTRUCTION NOTES:

FOUNDATION PLAN LEGEND

REFERENCED FINISH FLOOR ELEVATION = (+) 0'-0". RE: CIVIL FOR DATUM
ELEVATION (+) 352.5'.

-X' - X"

DENOTES BEARING DEPTH BELOW EXISTING GRADE (EXAMPLE).

DENOTES SHAFT DIAMETER (EXAMPLE).

FOUNDATION CONDITIONS NOTED DURING CONSTRUCTION, WHICH DIFFER FROM


THOSE DESCRIBED IN THE GEOTECHNICAL REPORT, SHALL BE REPORTED TO
THE ARCHITECT, STRUCTURAL ENGINEER, AND GEOTECHNICAL ENGINEER
BEFORE FURTHER CONSTRUCTION IS ATTEMPTED.

PX - XX/XX
- X'-X"

DENOTES BELL DIAMETER (EXAMPLE).

2.

SEE TYPICAL STRAP BEAM DETAIL AND ALTERNATE FOUNDATION TO BE USED ON


SHEET S-5.10 WHERE FOOTING CONFLICTS WITH EXISTING CONSTRUCTION. VERIFY
APPLICABILITY AND ORIENTATION WITH STRUCTURAL ENGINEER.

DENOTES COLUMN PLINT/PILASTER

3.

SEE SHEET S-5.10 FOR ALTERNATE STRAIGHT SHAFT FOUNDATION DETAIL FOR USE
WHEN PIERS ARE UNABLE TO BE BELLED AS SHOWN. VERIFY APPLICABILITY WITH
STRUCTURAL ENGINEER.

Issue
No.

Date

Description

DEC 09, 2015 ISSUE FOR SITE ROUGH GRADING / GARAGE


FONDATION PERMIT
01-18-2016 FOUNDATION REVISIONS

DENOTES OVERALL DEPTH

UNDERREAMED PIER.
SEE TYPICAL DETAIL ON SHEET S-5.00.

PC-XX x XX
+/- X"

GENERAL CONTRACTOR SHALL CONTACT STRUCTURAL ENGINEER IF THERE


ARE ANY UTILITIES LINES THAT CONFLICT WITH FOOTINGS PRIOR TO ANY
CONSTRUCTION IN THAT AREA.

DENOTES TOP OF PLINTH/PILASTER IN


RESPECT TO FINISH FLOOR ELEVATION +0'-0"

DENOTES STRAIGHT SHAFT (EXAMPLE).

GENERAL CONTRACTOR IS RESPONSIBLE FOR LOCATION OF FLOOR DRAINS


WHETHER OR NOT THEY ARE INDICATED ON THE STRUCTURAL DOCUMENTS.

TOP OF SLAB SPOT ELEVATION WITH RESPECT TO FINISH


FLOOR ELEVATION +0'-0". RE: ARHITECT FOR ADDITIONAL
INFORMATION.

DENOTES OVERALL WIDTH

DENOTES TOP OF PIER ELEVATION W/


RESPECT TO FIN FLOOR +0'-0" (EXAMPLE).

CONCRETE SLAB REINFORCING SHALL BE SUPPORTED BY SAND BEARING


PLATES. CAST SLAB ON 10 MIL VAPOR RETARDER OVER SUBGRADE PREPARED
AND COMPACTED PER THE REQUIREMENTS OUTLINED IN THE GEOTECHNICAL
REPORT AND PROJECT SPECIFICATIONS.

NOTIFY STRUCTURAL ENGINEER IF ANY EXISTING FOOTINGS WILL AFFECT THE ABILITY
TO PROVIDE FOUNDATION AS SHOWN.

1.

DENOTES UNDERREAMED PIER (EXAMPLE).

REFER TO GENERAL STRUCTURAL NOTES AND STANDARD FOUNDATION


DETAILS FOR ADDITIONAL INFORMATION.

TEXAS FIRM REGISTRAGTION NO. F-12745


4800 SUGAR GROVE, SUITE 315
STAFFORD. TEXAS 77477
T 713.933.1041
F 713.458.7758
www.ensighthayneswhaley.com
EHW-15-501-A

DENOTES BEARING DEPTH BELOW EXISTING GRADE (EXAMPLE).

GENERAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL DIMENSIONS WITH


ARCHITECTURAL DOCUMENTS BEFORE COMMENCING WORK AND SHALL NOTIFY
ARCHITECT/ENGINEER OF ANY DISCREPENCIES BEFORE ANY WORK
COMMENCES. REFER TO ARCHITECTURAL FOR OTHER DIMENSIONS NOT
INDICATED.

DENOTES SHAFT DIAMETER (EXAMPLE).


SX - XX
- X'-X"

8.

FOOTINGS ARE CENTERED UNDER COLUMNS. WHERE THERE ARE NO COLUMNS,


FOOTINGS ARE CENTERED UNDER GRADE BEAMS OR STRAP BEAMS (U.N.O.).

DENOTES TOP OF PIER ELEVATION W/


RESPECT TO FIN FLOOR +0'-0" (EXAMPLE).

9.

REFER TO ARCHITECTURAL DOCUMENTS FOR ALL SLAB DEPRESSION


LOCATIONS AND EXTENTS.

STRAIGHT SHAFT PIER.


SEE TYPICAL DETAIL ON SHEET S-5.00.

10. VERIFY ALL BRICK LEDGES AND EXTENTS WITH ARCHITECTURAL DOCUMENTS.
11. REFERENCE STRUCTURAL NOTES LOCATED ON SHEET S-0.XX FOR ADDITIONAL
INFORMATION.

17.5 17

12. REFERENCE SHEET S-5.XX FOR STANDARD DETAILS.

16.8 16.5

16

15

14

13

12

11

10

1.5 1.4

0.8

13. REFERENCE SHEET S-5.00 FOR PLINTH SCHEDULE AND DETAILS.

431' - 3" (OUT-TO-OUT OF CONCRETE)


10"

13' - 3 1/2"

25' - 0"

25' - 0"

25' - 0"

25' - 0"

25' - 0"

25' - 0"

25' - 0"

25' - 0"

25' - 0"

1' - 1"

25' - 0"

25' - 0"

25' - 0"

25' - 0"

5' - 10"

1' - 2"

15' - 2"

4' - 10 1/2"

1' - 1"
CL OF PIER

TYP

22

25' - 0"

2' - 2"

7' - 8 1/2"

5' - 2 1/2"

25' - 0"

RETAINING WALL. RE: ARCH FOR EXTENTS

2'-0" SLAB
TOS -5'-4"
BOS -7'-6"

S-5.05
4

03

C
A

BB

PC-60x60
PC-60x60
P50 - 54/144

03

6' - 1"

01(A)

P50 - GRADE
54/144

TYP

PC-60x60

8' - 0"

PC-54x54

8"-8'x36' APPROACH SLAB


TOS VARIES
BOS VARIES
21' - 4"

5' - 7"

18' - 8"

P50 - 54/144

P50 - 54/144

-9' - 0"

-9' - 0"

-9' - 0"

-9' - 0"

-9' - 0"

-9' - 0"

-9' - 0"

-9' - 0"
+0"

S-8.04

A.1

+0"

S-5.05

8' - 0"

+0"

1'xVARIES
RET WALL

-10"

SIM

01

P50 - 54/144

P50 - 54/144

P50 - 54/144

P50 - 54/144

P50 - 54/144

-4' - 0"

-4' - 0"

-4' - 0"

-4' - 0"

-4' - 0"

01

1'x9'-6"
RET WALL

S-5.08

PC-54x54

+0"

-10"

PC-54x54
-4' - 0"

-4' - 0"

PC-54x54
-7"

PC-54x54
+9"

01

1'-8"x3'-4"
GRADE
BEAM

P50 - 54/144

S50 - 54

PC-54x54

PC-60x66
-4' - 0"
P50 - 54/144

-10"

+0"

S50 - 54

1'-0"
SHEAR WALL

02

S-5.08

1'x9'-6"
RET WALL

S-5.08

-7' - 0"

P50 - 54/144

P50 - 54/144

-9' - 6"

-9' - 6"

P50 - 54/144
-7' - 0"

A.2

1001 Fannin Street, Suite 4040 | Houston, Texas 77002 USA


Phone 713.622.1180 | Fax 713.622.7021
www.morris-hz.com

S-5.07

P50 - 54/144

-9' - 6"

-9' - 6"

STONEHENGE HOLDINGS LLC


OWNER
SEE S-5.00 FOR
GRADE BEAM CHANGE
OF DEPTH DETAIL

MORRIS
ARCHITECT

HUITT-ZOLLARS, INC.

16

P50 - 54/144

TYP

-4' - 1 1/2"

PC-54x54
+1' - 7"

+0"

PC-36x30
+2' - 6"

MAINTAIN 2" GAP


BETWEEN COLUMN
AND WALLS

P50 - 54/144

04

PC-54x54
-6' - 0"

20

-1' - 11"

PILE CAP B
G.C. TO COORDINATE

S-5.05

21' - 4"

1'-8"x3'-4"
GRADE
BEAM

P50 - 54/144

PC-54x54
P50 - 54/144

-4' - 0"

-4' - 0"

7' - 6"

PC-54x54

-10"

-4' - 0"

TYP

16

18

14

P50 - 54/144

P50 - 54/144

P50 - 54/144

P50 - 54/144

-4' - 0"

-4' - 0"

-4' - 0"

-4' - 0"

P50 - 54/144

S-5.07

-7' - 4"
PC-60x66
-4' - 0"

36 x 30
+2' - 6"

PC-54x54
-7"

PC-54x54
-10"

PC-54x54
P50 - 54/144

PC-54x54
+9"

-4' - 1 1/2"

-9' - 6"

01

S-5.07

01

S-5.07

SIM

PC-54x54
P50 - 54/144

1'x9'-6"
RET WALL

S-5.08

P50 - 54/144

P50 - 54/144

P50 - 54/144

-9' - 6"

-9' - 6"

-9' - 6"

-9' - 6"

P50 - 54/144
-4' - 0"

02(A)

02

04

-9' - 6"

-10"

1'-0"
SHEAR WALL

S-5.08

S-5.08

S-5.05
01

4"

S-5.08

CONTROL/CONSTRUCTION
JOINTS AT EACH COLUMN LINE
AND MID BAYS AS SHOWN.
SEE 22/S-5.00, TYPICAL

C
A

01-18-2016

C
A
03

+0"

P50 - 54/120

P50 - 54/120

P50 - 54/120

P50 - 54/120

P50 - 54/120

P50 - 54/120

P50 - 54/120

-4' - 0"

-4' - 0"

-4' - 0"

-4' - 0"

-4' - 0"

-4' - 0"

-4' - 0"

PC-60x60

PC-60x60

PC-60x60

PC-60x60

PC-60x60

PC-60x60

P50 - 54/120
-4' - 0"
PC-60x60

PC-60x60

P50 - 54/120

P50 - 54/120

P50 - 54/120

-4' - 0"

-4' - 0"

-4' - 0"

PC-60x60

PC-60x60

04

02(A)

01(A)

S-5.05

S-5.05

S-5.05

TYP

-4' - 0"

-4' - 0"

+0"

03
S-8.03

PC-60x60

PC-60x60

4' - 0"
8' - 0"

10' - 8"
4' - 6"

25' - 0"

4' - 0"

17' - 0"

4' - 0"
8' - 0"

25' - 0"

4' - 0"

17' - 0"

4' - 0"
8' - 0"

25' - 0"

4' - 0"

17' - 0"

4' - 0"
8' - 0"

25' - 0"

4' - 0"

17' - 0"

4' - 0"
8' - 0"

25' - 0"

4' - 0"

17' - 0"

4' - 0"
8' - 0"

25' - 0"

4' - 0"

17' - 0"

4' - 0"
8' - 0"

25' - 0"

2' - 11"

2' - 11"

4' - 0"

18' - 1"

8' - 0"

18' - 1"

25' - 0"

2' - 2"

25' - 0"

4' - 0"
8' - 0"

4' - 0"

17' - 0"

4' - 0"
8' - 0"

25' - 0"

4' - 0"

17' - 0"
25' - 0"

4' - 0"

17' - 0"

4' - 0"
8' - 0"

25' - 0"

4' - 0"

17' - 0"

4' - 0"
8' - 0"

25' - 0"

4' - 0"

17' - 0"

8' - 0"

25' - 0"

5' - 10"

15' - 2"

15

14

13

12

11

10

Drawing Name

FOUNDATION PLAN LEVEL 1

1' - 2"

4' - 10 1/2"

16

R303928.03

21' - 0"
25' - 0"

5' - 10"

16.9 16.6 16.5

S-8.03

4' - 0"

Project Number

03
S-4.00

06
4' - 0"

8' - 0"

-4' - 0"

-4' - 0"

JANUARY 18, 2016

1.5 1.4

4' - 0"

D.8

1'-8"x3'-4"
GRADE
BEAM

TEXAS A&M CAIN HALL SITE


4
REDEVELOPMENT - VOLUME 4
500 GENE STALLINGS BOULEVARD,
COLLEGE STATION, TEXAS 77840

5" SLAB
TOS 0'-2"
BOS -0'-3"

PC-60x60
P50 - 54/120

1' - 2"

P50 - 54/120

5" SLAB
TOS 0'-2"
BOS -0'-3"

06
S-4.00

1' - 2"

1' - 6"

PC-60x60

17.5 17

Project Name

D.7

P50 - 54/120

S-8.01

5' - 2 1/2"

D.5

S50 - 54

+0"

10"

60' - 0"

PC-54x54

PC-54x54

P50 - 54/144

-10"

TECHNOLOGY / SECURITY CONSULTANT

-4' - 0"

+0"

P50 - 54/144
02

FERGUSON CONSULTING, INC.

PC-60x60

+0"

-4' - 0"

PC-54x54

BB

9' - 7"

S-5.05

12' - 6"

2'-6"x-9'-6"
RET WALL

PC-54x54

LANDSCAPE CONSULTANT

07

7' - 6"

1'x9'-6"
RET WALL

18

9' - 9"

10' - 0"

S50 - 54

1'xVARIES
RET WALL
PC-54x54

1'-0"
SHEAR WALL

S-5.05

-4' - 0"
PC-60x60

S-5.07

1'-8"x3'-4"
GRADE
BEAM

PC-54x54
+0"

P50 - 54/144

PC-54x54
+0"

16

S-WALL 1

PC-60x60
P50 - 54/144

+0"

CL OF OPENING AND CAP

12' - 6"

SLAB ON GRADE SHALL BE 5" THICK (U.N.O.)


NORMAL WEIGHT CONCRETE (3500 PSI)
REINFORCED WITH #3 @ 15" O.C. EACH WAY
AT MID DEPTH, TYPICAL.

-4' - 0"

1' - 7"

S-5.05

PC-54x54
-6' - 0"

-4' - 0"

02(A)

TYP

2' - 6"

PC-54x54
-2' - 5"

THE OFFICE OF JAMES BURNETT

16' - 9"

4"

-4' - 0"

-9' - 6"

P50 - 54/144

13' - 3"

DRIVE CANOPY
COLUMNS

-9' - 6"

S50 - 54

S-5.05
S50 - 54

-9' - 6"

-8' - 0"
PC-54x54
-4' - 2"

1' - 6"

06

-7' - 4"

PC-60x66
-4' - 0"

S-5.07

8"-8'x23' APPROACH SLAB


TOS VARIES
BOS VARIES

8' - 0"

S-5.07

PC-54x54

S50 - 54
-4' - 0"

S-5.05

PC-54x54

-6' - 10"

-6' - 10"

P50 - 54/144

PC-54x54
-6' - 0"

P50 - 54/144

P50 - 54/144

-4' - 0"

P50 - 54/144

8' - 0"

12' - 6"

4"

01(A)

-3' - 3"

P50 - 54/144

-5' - 11"

13' - 7"

2' - 0"

19' - 4"

08

24

-4' - 0"

PC-54x54

S-5.05

P25 - 24/48
(TYP -5'
@ -CANOPY)
6"

-4' - 0"

P50 - 54/144

1'-8"x3'-4"
GRADE
BEAM

P50 - 54/144

P50 - 54/144

MEP ENGINEER

241' - 0" (OUT-TO-OUT OF CONCRETE)

+0"

P50 - 54/144

14

BLUM CONSUTLING ENGINEER, INC.

60' - 0"

-4' - 0"

P50 - 54/144

PC-54x54
+3"
P50 - 54/144

STRUCTURAL ENGINEER

27' - 5"

APPROACH SLAB

PILE CAP A
G.C. TO COORDINATE

S-5.05

SLOPE

S-5.07

-4' - 0"

DOWN TO SUB-LEVEL

ENSIGHT HAYNES WHALEY, LLC

8' - 0"

10' - 0"

10' - 0"

S50 - 54

12' - 0"

CL OF OPENING

16' - 4"

-4' - 0"

S-5.05

20

16

UP TO LEVEL 2

5' - 8" 10' - 0"

S-5.05

2'-2"x3'-0"(from FNFLREL)
RET WALL

CIVIL ENGINEER

07

8"x4'-0"(max)
BUMPER WALL

125' - 2"

S50 - 54

3' - 8"

3' - 0"

12' - 6"

P50 - 54/144

19

FOUNDATION PLAN
SCALE: 1/16" = 1'-0"

Project Team

TYP

2'-6"x-9'-6"
RET WALL

10' - 0"

12' - 6"

S-5.05

12' - 3"

01(A)
S-5.05

-4' - 1 1/2"

-4' - 7 1/4"

21' - 5"

S50 - 54

2' - 0"

12' - 7"
19' - 3"

06

8' - 0"

5' - 6" 22' - 8"

P50 - 54/144

10' - 0" 5' - 0"

3' - 8"

+0"

2' - 6"

-9' - 6"
PC-54x54

PC-60x60

PC-54x54

-10"

P50 - 54/144

-9' - 6"
PC-54x54

PC-54x54

PC-54x54

PC-54x54
P50 - 54/144

-7' - 4"

PC-36x30
+2' - 6"

-4' - 0"

12' - 8"
19' - 4"

P50 - 54/144

06

38' - 7"
35' - 2"

S-5.05

-4' - 0"

S-3.00

06

P50 - 54/144

EXISTING FOUNDATION

PC-54x54

18
P50 - 54/144

S-5.05

-4' BEAM
- 0"

S-5.05

16

TYP

S-5.05

D.9

P50 - 54/144

8' - 0"

2' - 5"4' - 0"

-4' - 1'-8"x3'-4"
0"

D.2
D.5

P50 - 54/144

S-WALL 1

22' - 7"

35' - 2"

28' - 2"
31' - 10"
28' - 2"
14' - 9"

P50 - 54/144

01A

1'-0"
SHEAR WALL

S-5.05

PC-60x60

06
S-4.50

SEE 12/S-5.01. RE: ARCHITECT

PC-60x60

31' - 10"

241' - 0" (OUT-TO-OUT OF CONCRETE)

C.5

PC-60x60

0.8

PC-60x60

4' - 0"

3' - 0"

4"

4"

B.5

8"x4'x0"(max)
RET WALL

5' - 5 1/2"
4

PC-60x60

4' - 0"

4' - 0"

SEE S-5.00 FOR


GRADE BEAM CHANGE
OF DEPTH DETAIL

8' - 0"
8' - 0"

PC-60x60

+0"

S50 - 54

12' - 0"

35' - 9"

13' - 4"

A.4

PC-60x60

06

DN

21' - 4"

A.3

P50 - 54/144

-9' - 0"

S-8.02

PC-60x60

5" SLAB
TOS 0'-2"
BOS -0'-3"

1' - 6"

S-5.06

13' - 3"

S-5.06

EXTENTS OF FUTURE
HOTEL BUILDING
(FFE +351.5')

2'x9'-0"
DEEP GRADE BEAM

1' - 7"

17' - 2"

C
A

01A

44' - 2"

17A

13' - 7"

1' - 6"

5" SLAB
TOS 0'-2"
BOS -0'-3"

15
S-4.00

S-8.04

16
S-4.50

12' - 0"

5" SLAB
TOS -0'-10"
BOS -1'-3"

5" SLAB
TOS 0'-2"
BOS -0'-3"

18
S-4.00

1'-0" SLAB
TOS 0'-2"
BOS -0'-3"

TAMU NORTH

TRUE NORTH

PLAN NORTH

Graphic Scale: 1 inch = 16 feet

Scale:
0

16'

32'

48'

64'

As indicated

Drawing Number

S-1.01

Das könnte Ihnen auch gefallen