Sie sind auf Seite 1von 7

Routine Checks

GENERATOR

April 11, 201

PMI Revision 00

Generator Hydrogen Gas System


HYDROGEN COOLERS
COOLING WATER INLET/OUTLET TEMP.
HOT GAS /COLD GAS TEMP.
COOLING WATER FLOW.

HYDROGEN DRIERS
SILICA GEL CONDITION
ANY OIL TRACES
REGENERATION OF STANDBY DRIER.

GENERATOR CASING
CASING PRESSURE/ DROP RATE
CHECK ANY LEAKAGE BY TOXIMETER.
DEW POINT OF HYDROGEN.

April 11, 201

PMI Revision 00

Generator Stator Water System


STATOR WATER QUALITY
STATOR WATER PUMPS
STATOR WATER FLOW ADJUSTMENT
STATOR WATER PRESSURE
STATOR DP( `1.5 Ksc)

STATOR WATER COOLERS


STATOR WATER FILTERS
EXPANSION TANK & EJECTORS
POLISHING UNIT

April 11, 201

PMI Revision 00

Seal Oil System


SEAL OIL PUMPS(AC & DC )
SEAL OIL PRESSURE REGULATOR
SEAL OIL COOLERS
SEAL OIL FILTERS
SEAL OIL FLOW CONTROL
OIL TANKS S.O.T, S.O.S.T, I.O.T
VACUUM PUMP

April 11, 201

PMI Revision 00

Generator Excitation System


EXCITATION XMER
AVR
THYRISTOR BRIDGES
EXCITOR CARBON BRUSHES
LEAKAGE CURRENT AT BRG.

April 11, 201

PMI Revision 00

Transformers
GENERATOR TRANSFORMER
OIL LEVEL
CONSERVATOR (SILICA GEL CONDITION)
COOLER BANKS (OIL PUMP & FANS)
LIGHTENING ARRESTORS HEALTHINESS

UNIT AUX. TRANSFORMERS


OIL LEVEL
COOLING FANS

April 11, 201

PMI Revision 00

THANK YOU

April 11, 201

PMI Revision 00

Das könnte Ihnen auch gefallen