Beruflich Dokumente
Kultur Dokumente
Version 3.0
FS8600 Appliance
Deployment Guide
Date
Description
October2013
Initialrelease.
December2013
UpdatedforEnterpriseManager2014R1.2.
Caution: Indicateseitherpotentialdamagetohardwareorlossofdataandtellsyouhowtoavoid
theproblem.
Warning: Indicatesthatfailuretofollowdirectionscouldresultinpropertydamage,personal
injury,ordeath.
Contents
Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Related Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FS8600 Appliance Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Internal Backup Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Internal Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Internal Cache . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FluidFS Architecture Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage Center . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SAN Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Internal Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LAN/Client Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 Deployment Prerequisites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rack and Infrastructure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Network Credentials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SAN and Internal Network for Fibre Channel Appliances . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fibre Channel SAN Fabric . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Internal Network for Multi-Appliance Clusters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SAN and Internal Networks for iSCSI Appliances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Client Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IP Addresses and Network Infrastructure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Network Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Required Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dell Compellent
1
1
2
2
2
3
3
4
4
4
5
6
7
8
9
9
9
10
11
12
13
13
iii
Contents
Feature-Specific Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
SAN Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
15
16
16
17
18
19
19
20
21
22
22
23
25
25
26
27
27
27
27
37
39
42
iv
49
50
51
52
Contents
Dell Compellent
Contents
vi
Preface
ThisprefaceintroducestheDellCompellentFluidFSforFS8600appliancedocumentation.Itprovidesthe
purposeandaudienceofthisdocument,aswellasalistofrelatedpublications.
Purpose
TheDellCompellentFluidFS3.0FS8600ApplianceDeploymentGuideprovidesinformationaboutdeploying
anFS8600appliance,includingcablingtheappliancetotheStorageCenter(s)andthenetwork,and
deployingtheapplianceusingtheEnterpriseManagersoftware.Thetargetaudienceforthisdocumentis
DellCompellentinstallersandcertifiedbusinesspartnerswhoperformFS8600applianceinstallations.
Related Publications
ThefollowingdocumentscomprisethecoreDellCompellentFluidFSforFS8600appliancedocumentation
set:
DellCompellentFluidFSVersion3.0FS8600AppliancePreDeploymentRequirements
ProvidesachecklistthatassistsinpreparingtodeployanFS8600appliancepriortoaDellCompellent
installerorcertifiedbusinesspartnerarrivingonsitetoperformanFS8600applianceinstallation.The
targetaudienceforthisdocumentisDellCompellentinstallersandcertifiedbusinesspartnerswho
performFS8600applianceinstallations.
DellCompellentFluidFSVersion3.0FS8600ApplianceAdministratorsGuide
ProvidesinformationaboutusingtheEnterpriseManagersoftwaretomanageFS8600appliances,and
providesinformationaboutFS8600appliancemonitoringandtroubleshooting.Thetargetaudiencefor
thisdocumentiscustomers.
DellCompellentFluidFSVersion3.0FS8600ApplianceCLIReferenceGuide
ProvidesinformationabouttheFS8600appliancecommandlineinterface.Thetargetaudienceforthis
documentiscustomers.
DellCompellentFS8600ApplianceFluidFSVersion3.0SoftwareUpdateGuide
ProvidesinformationaboutupgradingtheFluidFSsoftwarefromversion2.0to3.0.Thetargetaudience
forthisdocumentiscustomers.
DellCompellentFluidFSVersion3.0FS8600ApplianceReleaseNotes
ProvidesinformationaboutFluidFSreleases,includingnewfeaturesandenhancements,openissues,
andresolvedissues.Thetargetaudienceforthisdocumentiscustomers.
DellCompellentFS8600ApplianceServiceGuide
ProvidesinformationaboutFS8600appliancehardware,systemcomponentreplacement,andsystem
troubleshooting.ThetargetaudienceforthisdocumentisDellCompellentinstallersandcertified
businesspartnerswhoperformFS8600appliancehardwareservice.
Dell Compellent
vii
DellNASApplianceSFP+ReplacementProcedure
ProvidesinformationaboutreplacingSFP+transceiversonaninactivesystem.Thetargetaudiencefor
thisdocumentisDellCompellentinstallersandcertifiedbusinesspartnerswhoperformFS8600
appliancehardwareservice.
DellCompellentEnterpriseManagerInstallationGuide
ProvidesinformationaboutinstallingandconfiguringtheEnterpriseManagerDataCollectorand
EnterpriseManagerClient.Thetargetaudienceforthisdocumentiscustomers.
DellCompellentEnterpriseManagerAdministratorsGuide
DescribeshowtousetheEnterpriseManagersoftwaretomanageStorageCenterandFS8600appliances.
Thetargetaudienceforthisdocumentiscustomers.
DellCompellentEnterpriseManagerReleaseNotes
ProvidesinformationaboutEnterpriseManagerreleases,includingnewfeaturesandenhancements,
openissues,andresolvedissues.Thetargetaudienceforthisdocumentiscustomers.
viii
Introduction
DeployingtheFS8600applianceincludesinstallingtheappliancehardware,connectingthe
FS8600appliancetotheStorageCenter(s)andtheclientnetwork,andconfiguringthe
FluidFScluster.
Contents
FS8600ApplianceOverview ................................................... 1
FluidFSArchitectureOverview ................................................ 3
Dell Compellent
1GbEthernetclientconnectivitywith8GbFibreChannelbackendconnectivitytothe
StorageCenter(s)
10GbEthernetclientconnectivitywith8GbFibreChannelbackendconnectivitytothe
StorageCenter(s)
10GbEthernetclientconnectivitywith10GbEthernetiSCSIbackendconnectivityto
theStorageCenter(s)
Chapter 1 Introduction
Internal Storage
EachNAScontrollerhasaninternalstoragedevicethatisusedonlyfortheFluidFSimages
andforacachestorageoffloadlocationintheeventofapowerfailure.Theinternalhard
drivedoesnotprovidetheNASstoragecapacity.
Internal Cache
EachNAScontrollerhasaninternalcachethatprovidesfastreadsandreliablewrites.
Hardware
FluidFScluster
StorageCenter
NASappliancenetworkinterfaceconnections
SANnetwork
Internalnetwork
LAN/clientnetwork
ThefollowingfigureshowsanoverviewoftheFS8600scaleoutNASarchitecture.
Storage Center
TheStorageCenterprovidestheFS8600scaleoutNASstoragecapacity;theFS8600cannot
beusedasastandaloneNASappliance.Thiseliminatestheneedtohaveseparatestorage
capacityforblockandfilestorage.Inaddition,StorageCenterfeatures,suchasDynamic
CapacityandDataProgression,areautomaticallyappliedtoNASvolumes.
Dell Compellent
Chapter 1 Introduction
SAN Network
TheFS8600sharesabackendinfrastructurewiththeStorageCenter.TheSANnetwork
connectstheFS8600totheStorageCenterandcarriestheblockleveltraffic.TheFS8600
communicateswiththeStorageCenterusingeithertheiSCSIorFibreChannelprotocol,
dependingonwhichNASapplianceconfigurationyoupurchased.
Internal Network
TheinternalnetworkisusedforcommunicationbetweenNAScontrollers.Eachofthe
NAScontrollersintheFluidFSclustermusthaveaccesstoallotherNAScontrollersinthe
FluidFSclustertoachievethefollowinggoals:
ProvideconnectivityforFluidFSclustercreation
Actasaheartbeatmechanismtomaintainhighavailability
EnableinternaldatatransferbetweenNAScontrollers
EnablecachemirroringbetweenNAScontrollers
EnablebalancedclientdistributionbetweenNAScontrollers
LAN/Client Network
TheLAN/clientnetworkisusedforclientaccesstotheCIFSsharesandNFSexports,and
itisalsousedbythestorageadministratortomanagetheFluidFScluster.Theclient
networkisassignedoneormorevirtualIPaddresses(clientVIPs)thatallowclientsto
accesstheFluidFSclusterasasingleentity.TheclientVIPalsoenablesloadbalancing
betweenNAScontrollers,andensuresfailoverintheeventofaNAScontrollerfailure.
IfclientaccesstotheFluidFSclusterisnotthrougharouter(inotherwords,aflatnetwork),
defineoneclientVIPperNAScontroller.IfclientsaccesstheFluidFSclusterthrougha
router,defineaclientVIPforeachclientinterfaceportperNAScontroller.
Deployment Prerequisites
Verifythattheprerequisitesaremetbeforeproceedingwiththedeploymentprocess.
Contents
RackandInfrastructure ....................................................... 6
Materials .................................................................... 7
NetworkCredentials .......................................................... 8
SANandInternalNetworkforFibreChannelAppliances .......................... 9
SANandInternalNetworksforiSCSIAppliances ............................... 10
ClientNetwork ............................................................. 11
IPAddressesandNetworkInfrastructure ...................................... 12
NetworkPorts .............................................................. 13
SANConfiguration .......................................................... 14
Dell Compellent
Prerequisite
2UrackspaceforeachFS8600applianceinanindustrystandard48.3cm(19inch)rack
Therackmustbefourpost,squareholeorroundhole,andtoolless.
Therackmustberatedfor540kg(1200pounds)staticloadorgreater.
Therackdepthmustbeatleast100cm(40inches)fromthefronttothebackoftherack.
Thedistancebetweentheinsideofthefrontandbackrackposts(themountingsurfaces)must
be61cm(24inches)to90cm(36inches).
Theremustbeatleast4.1cm(1.6inches)betweentherackdoorandthefrontofthehardware
toaccommodatethefrontbezel.
Therack(withinstalledhardware)mustmeetthesafetyrequirementsofUL609501andIEC
609501.
RackhaspowersourcesforbothcontrollersineachFS8600appliance,preferablyfromdifferent
circuits
Thevoltagerangemustbe90to264VAC.
Eachpowersourcemusthavesufficientelectricaloverloadprotection.
InNorthAmerica,connecttheappliancetoasourceofpowerwithovercurrentprotection
providedbya20Aorlessdevice(UL489circuitbreakers).
InEurope,theovercurrentprotectionmustbeprovidedbya20Aorlessdevice(IEC
circuitbreakers).
RackhasconnectivitytotheSANandclientnetworks
Materials
Materials
Makesurethefollowingmaterialsareavailable.
Prerequisite
CompletedSolutionIntegrationDocument(SID)
VGAmonitorandUSBkeyboard(forinitialconfiguration)
CablesforSAN
FibreChannelwith1GbEapplianceorFibreChannelwith10GbEappliance:FourLCFibre
Channelcablesforeachappliance
10GbEiSCSIappliance:FourLCopticalfibercablesorTwinaxcablesforeachappliance
Cablesforclientnetwork
FibreChannelwith1GbEappliance:EightRJ45/Cat5eorbettercablesforeachappliance
FibreChannelwith10GbEapplianceor10GbEiSCSIappliance:FourLCopticalfiber
cablesorTwinaxcablesforeachappliance
Cablesforinternalnetwork
FibreChannelwith1GbEappliance:
Singleappliance:FourRJ45/Cat5eorbettercablesforeachappliance(controllersare
directlyconnectedtoeachother)
Multipleappliances:EightRJ45/Cat5eorbettercablesforeachappliance
FibreChannelwith10GbEappliance:
Singleappliance:TwoLCopticalfibercablesorTwinaxcables(controllersaredirectly
connectedtoeachothertwoTwinaxcablesshippedwitheachappliance)
Multipleappliances:FourLCopticalfibercablesorTwinaxcablesforeachappliance
10GbEiSCSIappliance:None(sharedwithSANcables)
(10GbEopticalnetworksonly)IntelSFP+transceiverspurchasedfromDellforuseinanFS8600
appliance
FibreChannelwith10GbEappliance:
Clientnetwork:FourIntelSFP+transceiversforeachappliance
Internalnetwork:FourIntelSFP+transceiversforeachappliance
10GbEiSCSIappliance:
Clientnetwork:FourIntelSFP+transceiversforeachappliance
SAN/internalnetwork:FourIntelSFP+transceiversforeachappliance
Note: TheFS8600applianceiscompatiblewithspecificIntelSFP+transceiverspurchasedonly
fromDell.OtherSFP+transceivermodelsdonotworkintheFS8600Appliance.
Dell Compellent
Network Credentials
Makesurethefollowingnetworkcredentialsareavailabletocompletethedeployment
successfully.
Prerequisite
(FibreChannelonly)CredentialstoupdateFibreChannelzoning
(ActiveDirectoryonly)SiteinformationandcredentialstojointheFluidFSclustertoActive
Directory
AnyofthefollowingdomainuserscanbeusedtojointheclustertoActiveDirectory:
DomainAdminaccount(preferredmethod)
Domainaccountthathasbeendelegatedthejoinacomputertothedomainprivilegeand
fullcontroloverallcomputerobjectsinthedomain
DomainOrganizationalUnit(OU)adminaccountthathasbeendelegatedthejoina
computertothedomainprivilegeandfullcontroloverobjectswithinthatOU,including
computerobjects
BeforejoiningtheFluidFSclustertothedomain,acomputerobjectmustbecreatedbythe
OUadminfortheFluidFScluster.
TheFluidFSclustercomputerobjectnameandNetBIOSnamemustmatch.
TheFluidFSclustercomputerobjectpermissionsmustbeconfiguredtoallowtheOU
adminaccounttojoinittoadomain.
(LDAP/NISonly)SiteinformationandcredentialstoconfigureLDAPorNISdirectoryservices
fortheFluidFScluster
(Optional)CredentialstoaddDNSrecordsfortheFluidFScluster
Prerequisite
FibreChannelswitch(es)canbereachedfromtherack
AtleastoneswitchmustbeavailabletoconnecttheFluidFSclustertotheStorageCenter.An
FS8600appliancecannotbedirectlyconnectedtoaStorageCenter.
Forhighavailability,deploytwoswitches(oneforeachStorageCenterfaultdomain).
FibreChannelswitchinfrastructurehasfourportsavailableforeachFS8600appliance(allfour
portsmustbeconnected)
Prerequisite
1GbEor10GbEswitch(es)canbereachedfromtherack
Inamultiapplianceconfiguration,aswitchisrequired.Althoughthebestpracticeistoisolate
internalandclienttrafficonseparatephysicalnetworks,itispossibletousethesameswitchand
useseparatelogicalnetworksbyconfiguringVLANs.
Switchinfrastructurehassufficientportsavailable
FibreChannelwith1GbEappliance:EightRJ45connectionsforeachappliance
FibreChannelwith10GbEappliance:FourLCopticalfiberorSFP+(Twinax)connectionsfor
eachappliance
AllswitchportsconnectedtoFS8600appliancescancommunicatewitheachotheroveran
untaggedVLAN
FlowControlisenabledontheswitch(es)
Unicaststormcontrolisdisabledontheswitch(es)
Jumboframesareenabledontheswitch(es)tosupportaframesizeof9000bytes
DellPowerConnectandForce10switchesmustbeconfiguredto9216MTU.
SwitchesfromvendorsotherthanDellmightrequireadifferentMTUconfigurationtoaccept
9000byteframes.
Switch(es)allowmulticastbetweenallportsconnectedtoFS8600appliances
IPv6isenabledontheswitchportsconnectedtoFS8600appliances
IPv6linklocaladdressingisusedforinternalnetworkcommunication.RoutingofIPv6traffic
isnotrequiredontheinternalnetworkswitches.
Dell Compellent
IGMPand/orMLDsnoopingaredisabledontheswitchportsconnectedtoFS8600appliances
AllswitchportsconnectedtoFS8600appliancesaresetasedgeportsorPortFasttoskip
SpanningTreenegotiation
Prerequisite
10GbEswitch(es)canbereachedfromtherack
AtleastoneswitchmustbeavailabletoconnecttheFluidFSclustertotheStorageCenter.An
FS8600appliancecannotbedirectlyconnectedtoaStorageCenter.
Forhighavailability,deploytwoswitches(oneforeachStorageCenterfaultdomain).
10GbEswitchinfrastructurehasfourLCOpticalorSFP+(Twinax)connectionsavailableforeach
FS8600appliance
AllswitchportsconnectedtoFS8600appliance(s)cancommunicatewitheachotheroveran
untaggedVLAN
Note: Ifmultipleswitchesareused,communicationbetweenthemmustbeallowed.
OneuniqueVLANisconfiguredforeachiSCSIsubnet(StorageCenterfaultdomain)
FlowControlisenabledontheswitch(es)
Unicaststormcontrolisdisabledontheswitch(es)
Jumboframesareenabledontheswitch(es)tosupportaframesizeof9000bytes
DellPowerConnectandForce10switchesmustbeconfiguredto9216MTU.
SwitchesfromvendorsotherthanDellmightrequireadifferentMTUconfigurationtoaccept
9000byteframes.
Switch(es)allowmulticastbetweenallportsontheiSCSI/internalnetwork
IPv6isenabledontheswitchportsconnectedtoFS8600appliance(s)
IPv6linklocaladdressingisusedforinternalnetworkcommunication.RoutingofIPv6traffic
isnotrequiredontheiSCSI/internalnetworkswitches.
10
IGMPand/orMLDsnoopingaredisabledontheswitchportsconnectedtoFS8600appliance(s)
AllswitchportsconnectedtoFS8600appliance(s)aresetasedgeportsorPortFasttoskip
SpanningTreenegotiation
Client Network
Client Network
Makesuretheclientnetworkmeetsthefollowingprerequisites.Theclientnetworkisused
byclientstoaccessCIFSsharesorNFSexports.Itisalsothenetworkusedforreplication,
backup,andadministration.
Prerequisite
1GbEor10GbEswitch(es)canbereachedfromtherack
Toensurehighavailabilitytotheclientnetwork,Dellrecommendsusingaswitchstackor
Directorclassswitches.Distributingtheclientnetworkportsacrossdiscreteswitches/bladesin
thestackcreatesaredundantconnectiontothecorenetwork,allowingfileaccesstocontinue
afterasingleswitchfailure.
EthernetswitchinfrastructurehasportsavailableforeachFS8600appliance
FibreChannelwith1GbEappliance:EightRJ45portsforeachappliance
FibreChannelwith10GbEapplianceor10GbEiSCSIappliance:FourLCOpticalorSFP+
(Twinax)connectionsforeachappliance
AllclientportsareinthesamebroadcastdomainorportbasedVLAN
Switch(es)areconfiguredtouseMTUsizeequaltoorgreaterthantheminimumsupported
MTU
DellForce10switchesmustbeconfiguredtouseMTU1554orgreater.
DellPowerConnectswitchesmustbeconfiguredtouseMTU1518orgreater.
Ifjumboframesareusedontheclientnetwork,theswitch(es)andclientsmustbeconfigured
touseMTU9000.
Dell Compellent
(Recommendedbutnotrequired)Flowcontrolisenabledontheswitch(es)
11
Prerequisite
IPaddressesreservedfortheFluidFSclusterontheclientnetwork
TwocontrollerIPaddressesforeachappliance(oneforeachcontroller)
ClientVIPs:
Minimum:OneclientVIPforeachcluster
Flatnetworkrecommendation:TwoclientVIPsforeachappliance(oneforeach
controller)
Routednetworkrecommendation:OneclientVIPforeachFS8600clientnetworkport
ClassCsubnetreservedfortheFluidFSclusterontheinternalnetwork
(iSCSIonly)FourIPaddressesreservedontheiSCSISANnetworkforeachappliance(twofor
eachcontroller)
NetworkresourceinformationforFluidFSclusterconfiguration
ClientnetworkdefaultgatewayIPaddress
(Optional)DNSserverIPaddress(es)
(Optional)NTPserverhostname(s)orIPaddress(es)
(Optional)ActiveDirectorydomaincontrollerhostnameorIPaddress(es)
(Optional)LDAPserverhostnameorIPaddress(es)
(Optional)NISserverhostnameorIPaddress(es)
(Optional)NDMPDMAserverIPaddress(es)
12
Network Ports
Network Ports
Makesuretherequiredandfeaturespecificportsareallowedonthenetwork.
Prerequisite
Requiredportsareallowed
Featurespecificportsareallowedasneeded
Required Ports
ThefollowingtablesummarizesportsthatarerequiredforallFluidFSclusters.
Port
Protocol
Service Name
22
TCP
SSH
53
TCP
DNS
80
TCP
Internalsystemuse
111
TCPandUDP
portmap
427
TCPandUDP
SLP
443
TCP
Internalsystemuse
445
TCPandUDP
CIFS/SMB
20492049+(domainnumber1)
TCPandUDP
NFS
35451
TCP
EnterpriseManagercommunication
40004000+(domainnumber1)
TCPandUDP
statd
40504050+(domainnumber1)
TCPandUDP
NLM(lockmanager)
50015001+(domainnumber1)
TCPandUDP
mount
50515051+(domainnumber1)
TCPandUDP
quota
44421
TCP
FTP
4443044439
TCP
FTP(Passive)
Feature-Specific Ports
Thefollowingtablesummarizesportsthatarerequired,dependingonenabledfeatures.
Dell Compellent
Port
Protocol
Service Name
88
TCPandUDP
Kerberos
123
UDP
NTP
135
TCP
ADRPC
138
UDP
NetBIOS
139
TCP
NetBIOS
161
UDP
SNMPAgent
162
TCP
SNMPtrap
13
Port
Protocol
Service Name
389
TCPandUDP
LDAP
464
TCPandUDP
Kerberosv5
543
TCP
Kerberoslogin
544
TCP
Kerberosremoteshell
636
TCP
LDAPoverTLS/SSL
711
UDP
NIS
714
TCP
NIS
749
TCPandUDP
Kerberosadministration
1344
TCP
AntivirusICAP
3268
TCP
LDAPglobalcatalog
3269
TCP
LDAPglobalcatalogoverTLS/SSL
8004
TCP
ScanEngineserverWebUI(AVhost)
10000
TCP
NDMP
1055010551,
1056010568
TCP
Replication
SAN Configuration
MakesureStorageCenterandEnterpriseManagerareinstalledandsatisfythedeployment
prerequisites.
Prerequisite
StorageCenter6.3.10orlaterdeployedtoprovidestoragefortheNASpool.
AsingleFluidFSclustersupports12StorageCenters.
Fordeploymentinstructions,seetheDellCompellentStorageCenterDeploymentGuide.
Forupgradeinstructions,seetheDellCompellentStorageCenterSoftwareUpdateGuide.
EachStorageCentercertificatecontainsthehostnameormanagementIPaddressusedtoadd
theStorageCentertoEnterpriseManager.ForinstructionsonregeneratinganSSLcertificate,see
theStorageCenterAdministratorsGuide.
(Optional)StorageCenter(s)canbereachedbyCopilotthroughSecureConsoletoassistwith
troubleshooting.
EnterpriseManager2014R1orlaterinstalledandconfigured.
DellCompellentrecommendsusingthelatestEnterpriseManagerversion.
SeetheDellCompellentEnterpriseManagerInstallationGuidefordetailedinstructions.
14
StorageCenter(s)addedtoEnterpriseManager.
EnterpriseManagercansuccessfullysenddatatoDellTechnicalSupportServicesusingPhone
Home.
Contents
InstalltheFS8600Hardware .................................................. 15
ConfigureNetworkConnectionsforFCAppliances(1GbE) ....................... 16
ConfigureNetworkConnectionsforFCAppliances(10GbE) ...................... 19
ConfigureNetworkConnectionsfor10GbEiSCSIAppliances ..................... 22
Prerequisites
Therackthatwillhosttheappliance(s)mustmeettheprerequisiteslistedinRackand
Infrastructureonpage 6.
Steps
1 Unpackthehardware.
2 Locatethefollowingcomponentsforeachappliance.
FS8600appliance
Bezel
Twopowercables
Railkit
SFP+transceivers(iforderedforopticalnetworks)
(FibreChannelwith10GbEappliancesonly)Two1metertwinaxcables(forsingle
applianceinternalnetworkconnectivitybetweencontrollers)
Twoportlabeltags(oneattachedtoeachcontroller)
Cablelabels
3 MounteachFS8600applianceintherack.Seethedocumentincludedwiththerailkit
forinstructions.
4 ConnectbothcontrollersineachFS8600appliancetoapowersource.
Dell Compellent
15
Clientnetwork:EachcontrollerhasmultipleconnectionstoeachstackedEthernet
switch.
Internalnetwork:Thecontrollersaredirectlyconnectedtoeachotherwithfour
Ethernetcables.
FibreChannelSAN:EachcontrollerhasaconnectiontoeachFCfabric(StorageCenter
faultdomain).
Client Network
Internal Network
FC SAN
16
Clientnetwork:EachcontrollerhasmultipleconnectionstoeachstackedEthernet
switch.
Internalnetwork:Eachcontrollerhasmultipleconnectionstothestackedinternal
networkEthernetswitches.
FibreChannelSAN:EachcontrollerhasaconnectiontoeachFCfabric(StorageCenter
faultdomain).
Note: Tosimplifythediagram,onlyoneFS8600applianceisshown.Additional
appliancesintheclustermustbeconnectedtothesameclientnetwork,internal
network,andFCSANfabric.
Client Network
Internal Network
FC SAN
Dell Compellent
17
Prerequisites
LCopticalfiberandEthernetcablesmustbeavailable.SeeMaterialsonpage 7.
TheSANnetworkmustmeetconfigurationrequirements.SeeSANandInternal
NetworkforFibreChannelAppliancesonpage 9.
Theclientnetworkmustmeetconfigurationrequirements.SeeClientNetworkon
page 11.
Steps
1 ConnecteachappliancetotheFibreChannelSANfabric(s).
Foreachcontroller,useLCopticalfibercablesconnectbothFibreChannelportsto
thefabric.
IftherearetwoFibreChannelfabrics(StorageCenterfaultdomains),makesure
eachcontrollerisconnectedtobothfabrics.
2 Connecteachappliancetotheinternalnetwork.
Singleappliancecluster:
UseCategory5eorbetterEthernetcablestodirectlyconnecteachcontroller0
internalporttothecorrespondingcontroller1internalport.
Makesureallfourinternalportsareconnectedforeachcontroller.
Multiappliancecluster:
UseCategory5eorbetterEthernetcablestoconnectallcontrollerinternalports
totheinternalnetworkEthernetswitches.
Makesureallfourinternalportsareconnectedforeachcontroller.
3 Connecteachappliancetotheclientnetwork.
Foreachcontroller,useCategory5eorbetterEthernetcablestoconnectallfour
clientportstoclientnetworkEthernetswitches.
Iftherearemultipleswitches,makesureeachcontrollerisconnectedtoeachswitch.
4 Usethecablelabelsshippedwiththeappliancetolabeleachcable.
18
Clientnetwork:EachcontrollerhasaconnectiontoeachstackedEthernetswitch.
Internalnetwork:Thecontrollersaredirectlyconnectedtoeachotherwithtwotwinax
cables.
FibreChannelSAN:EachcontrollerhasaconnectiontoeachFCfabric(StorageCenter
faultdomain).
Client Network
Internal Network
FC SAN
Dell Compellent
19
Clientnetwork:EachcontrollerhasmultipleconnectionstoeachstackedEthernet
switch.
Internalnetwork:Eachcontrollerhasmultipleconnectionstothestackedinternal
networkEthernetswitches.
FibreChannelSAN:EachcontrollerhasaconnectiontoeachFCfabric(StorageCenter
faultdomain).
Note: Tosimplifythediagram,onlyoneFS8600applianceisshown.Additional
appliancesintheclustermustbeconnectedtothesameclientnetwork,internal
network,andFCSANfabric.
Internal Network
Client Network
FC SAN
20
Prerequisites
LCopticalfiberand/ortwinaxcablesmustbeavailable.SeeMaterialsonpage 7.
TheSANnetworkmustmeetconfigurationrequirements.SeeSANandInternal
NetworkforFibreChannelAppliancesonpage 9.
Theclientnetworkmustmeetconfigurationrequirements.SeeClientNetworkon
page 11.
Steps
1 ConnecteachappliancetotheFibreChannelSANfabric(s).
Foreachcontroller,useLCopticalfibercablesconnectbothFibreChannelportsto
thefabric.
IftherearetwoFibreChannelfabrics(StorageCenterfaultdomains),makesure
eachcontrollerisconnectedtobothfabrics.
2 Connecteachappliancetotheinternalnetwork.
Singleappliancecluster:
Usetwinaxcablestodirectlyconnecteachcontroller0internalporttothe
correspondingcontroller1internalport.
Makesurebothinternalportsareconnectedforeachcontroller.
Multiappliancecluster:
UseLCopticalfiberortwinaxcablestoconnectallcontrollerinternalportstothe
internalnetworkEthernetswitches.
Makesurebothinternalportsareconnectedforeachcontroller.
3 Connecteachappliancetotheclientnetwork.
Foreachcontroller,useLCopticalfiberortwinaxcablestoconnectbothclientports
toclientnetworkEthernetswitches.
Iftherearemultipleswitches,makesureeachcontrollerisconnectedtoeachswitch.
4 Usethecablelabelsshippedwiththeappliancetolabeleachcable.
Dell Compellent
21
22
Clientnetwork:EachcontrollerhasmultipleconnectionstoeachstackedEthernet
switch.
SAN/Internalnetwork:Eachcontrollerhasmultipleconnectionstothestacked
internal/SANnetworkEthernetswitches.
AuniqueVLANisconfiguredfortheiSCSIsubnettowhichcontrollereth30
interfaces(upperrightport)areconnected.
AuniqueVLANisconfiguredfortheiSCSIsubnettowhichcontrollereth31
interfaces(lowerrightport)areconnected.
Internaltrafficbetweenthecontrollersisuntagged.
TheStorageCenterVLANscanbetaggedoruntagged,dependingonwhether
VLANtaggingisenabledfortheswitchandtheStorageCenteriSCSII/Ocards.
Prerequisites
LCopticalfiberand/ortwinaxcablesmustbeavailable.SeeMaterialsonpage 7.
TheSANnetworkmustmeetconfigurationrequirements.SeeSANandInternal
NetworksforiSCSIAppliancesonpage 10.
Theclientnetworkmustmeetconfigurationrequirements.SeeClientNetworkon
page 11.
Steps
1 ConnecteachappliancetotheSAN/internalnetwork.
UseLCopticalfiberortwinaxcablestoconnectallcontrollerinternal/iSCSIportsto
theSAN/internalnetworkEthernetswitches.
Forallcontrollers,eth30(upperrightport),mustbeconnectedtothesame
subnet.
Forallcontrollers,eth31(lowerrightport),mustbeconnectedtothesame
subnet.
Makesureeachcontrollerisconnectedtoeachswitch.
2 Connecteachappliancetotheclientnetwork.
Foreachcontroller,useLCopticalfiberortwinaxcablestoconnectbothclientports
toclientnetworkEthernetswitches.
Makesureeachcontrollerisconnectedtoeachswitch.
3 Usethecablelabelsshippedwiththeappliancetolabeleachcable.
Dell Compellent
23
24
Contents
ConfigureFluidFSClusterNetworkSettings .................................... 25
UseEnterpriseManagertoConfiguretheFluidFSCluster ........................ 27
Prerequisites
YoumusthaveaUSBkeyboardandVGAmonitor.
AllcontrollersintheclustermustberunningFluidFS3.0.Ifthecontrollersshipped
fromthefactorywithFluidFS2.0,upgradeto3.0beforecontinuingwithdeployment.
SeeAppendix A:UpgradeanAppliancetoFluidFS3.0,onpage 55.
Allcontrollersintheclustermustbepoweredoninstandbymode.
Steps
1 ConnectaVGAmonitorandUSBkeyboardtocontroller0.
Controller0islocatedontheleftwhenviewedfromtherearinthefirstappliance.
Ifyouareconfiguringamultiappliancecluster,connecttocontroller0inthefirst
appliance.
2 Fromthecommandline,typethefollowingcommandattheloginasprompt:
cli
Dell Compellent
25
3 TypetheFluidFSclusteradministratorusernameattheloginasprompt.Thedefault
usernameisAdministrator.
4 TypetheFluidFSclusteradministratorpasswordatthe<user_name>spassword
prompt.Stor@ge!isthedefaultpassword.YouareloggedontotheCLIandaWelcome
windowisdisplayed,listingtheinstalledFluidFSversionandtheavailablecommands
inthemainmenu.
Connect to the FluidFS Cluster CLI Using the iBMC Virtual KVM
LogontotheCLIusingtheiBMC(IntegratedBaseboardManagementController)virtual
KVM.
Prerequisites
YoumusthavealaptopwithJavainstalled.
AllcontrollersintheclustermustberunningFluidFS3.0.Ifthecontrollersshipped
fromthefactorywithFluidFS2.0,upgradeto3.0beforecontinuingwithdeployment.
SeeAppendix A:UpgradeanAppliancetoFluidFS3.0,onpage 55.
Allcontrollersintheclustermustbepoweredoninstandbymode.
Steps
1 ConnectalaptoptotheLOM(LightsOutManagement)portoncontroller0usinga
Cat5/6cable.
Controller0islocatedontheleftwhenviewedfromtherearinthefirstappliance.
TheLOMportislocatedonthelowerrightwhenviewedfromtherearofa
controller.
Ifyouareconfiguringamultiappliancecluster,connecttocontroller0inthefirst
appliance.
2 SettheLANportIPaddressofthelaptopto192.168.254.200/255.255.255.0.
3 Openawebbrowseronthelaptop.Intheaddressbarofthewebbrowser,typehttp://
192.168.254.253.TheiBMCloginpageappears.
4 LogintotheiBMC.TheUsernameisADMINandthepasswordisN@sst0r3.
5 ClickLaunchJavaKVMClient.TheFluidFSclusterCLIappears.
6 Fromthecommandline,typethefollowingcommandattheloginasprompt:
cli
7 TypetheFluidFSclusteradministratorusernameattheloginasprompt.Thedefault
usernameisAdministrator.
8 TypetheFluidFSclusteradministratorpasswordatthe<user_name>spassword
prompt.Stor@ge!isthedefaultpassword.YouareloggedontotheCLIandaWelcome
windowisdisplayed,listingtheinstalledFluidFSversionandtheavailablecommands
inthemainmenu.
Prerequisites
IPaddressesmustbereservedfortheFluidFSclusterontheclientnetwork.SeeIP
AddressesandNetworkInfrastructureonpage 12.
26
Steps
1 Runthefollowingcommandtosettheclientsubnetmask,optionalVLANID,
controllerIPaddresses,andaclientVIP.
CLI> networking subnets add [netmask] -VLANTag [VLAN ID]
-PublicIPs [ClientVIP1,ClientVIP2,ClientVIPn]
-PrivateIPs [ControllerIP1,ControllerIP2,ControllerIPn]
2 Runthefollowingcommandtoconfigurethedefaultgateway.
CLI> networking default-gateway add [gateway IP address]
Prerequisites
MakesurethefollowingprerequisitesaremetbeforeconfiguringtheFluidFSclusterwith
EnterpriseManager.
Youmusthavetherequirednetworkcredentials.SeeNetworkCredentialsonpage 8.
Requiredportsmustbeallowedonthenetwork.SeeNetworkPortsonpage 13.
EnterpriseManagerandStorageCentermustbedeployedandconfigured.SeeSAN
Configurationonpage 14.
TheFluidFSclustermustbeconnectedtotheSAN,clientnetwork,andinternal
network.SeeChapter 3:InstallandConnecttheFS8600Hardware,onpage 15.
Dell Compellent
27
1 IntheHostorIPAddressfield,typeFluidFSclusterclientVIP.
2 IntheUserNamefield,typeAdministrator.
3 InthePasswordfield,typethepasswordfortheFluidFSAdministratoraccount.
Note: Stor@ge!isthedefaultpasswordfortheAdministratoraccount.
4 IntheFolderpane,selecttheparentfolderfortheFluidFScluster.Foldersallowyouto
organizeFluidFSclusters.
5 ClickNext.AninformationalpageappearsbrieflywhileEnterpriseManager
communicateswiththeFluidFSCluster.Aftercommunicationisestablished,theEnd
UserLicenseAgreementappears.
28
1 IntheApproverNamefield,typethenameofthecustomerthatacceptstheEndUser
LicenseAgreement.
2 IntheApproverTitlefield,typethetitleofthecustomerthatacceptstheEndUser
LicenseAgreement.
3 ClickNext.TheConfigureGeneralSettingspageappears.
1 IntheNamefield,typetheclustername.
2 ClickNext.TheInternalNetworkpageappears.
Dell Compellent
29
Internal Network
EnteraclassCnetworkrangefortheinternalnetwork.
1 IntheClassCRangefield,typethenetworkaddressfortheclassCrange.
2 ClickNext.TheSelectAppliancespageappears.
30
Select Appliances
UsetheAddApplianceandRemoveAppliancebuttonstoincludeorexcludeadditional
appliancestoincludeinthecluster.
1 Addorremoveappliancesfromthecluster.
Toaddanappliance,selectanapplianceintheupperpane,thenclickAdd
Appliance.
Toremoveandappliance,selectanapplianceinthelowerpane,thenclickRemove
Appliance.
Note: Allappliancesinasingleclustermustbethesamemodel.
2 ClickNext.TheConfigureClientNetworkpageappears.
Dell Compellent
31
1 ConfirmthattheNetmaskandVLANTagfieldsdisplaythecorrectnetmaskand
VLANIDfortheclientnetwork.Modifythesefieldsifnecessary.
2 IntheVirtualIPv4Addressestable,defineadditionalclientVIPsforthecluster.Toadd
aVIP,clickAdd,typetheIPaddressinthedialogbox,andthenclickOK.
Minimumrequirement:OneclientVIPforeachcluster
Flatnetworkrecommendation:TwoclientVIPsforeachappliance(oneforeach
controller)
Routednetworkrecommendation:OneclientVIPforeachFS8600clientnetwork
port
3 IntheControllerIPv4Addressestable,defineanIPaddressforeachcontrollerinthe
cluster.
a Selectthecontrollerinthetable,thenclickEditSettings.
b IntheIPAddressfield,typeanIPaddressforthecontroller.
c
ClickOK.
4 ClickNext.AnAddFluidFSClusterprogresspageappearswhiletheclusterisbeing
created.
Note: Theclustercreationprocesstakesabout10minutesforasingle
applianceandlongerformultipleappliances.
32
Whentheprocessiscomplete,ifyouconfiguredadefaultgatewayfortheFluidFS
clusterusingtheCLIbeforerunningtheAddFluidFSClusterwizard,theSet
SupportUserPasswordpageappears.SeeSetSupportUserPasswordonpage 33.
Whentheprocessiscomplete,ifyouhavenotconfiguredadefaultgatewayforthe
FluidFScluster,theConfigureDefaultGatewaypageappears.SeeConfigure
DefaultGatewayonpage 33.
1 IntheGatewayIPv4Addressfield,typethedefaultgatewayIPaddress.
2 ClickNext.TheSetSupportUserPasswordpageappears.
1 InthePasswordfield,typeapasswordforthesupportaccount.
2 IntheConfirmPasswordfield,retypethepassword.
3 (Optional)SelecttheSupportAccesscheckboxtoenablethesupportaccount.
4 ClickNext.TheConfigureDNSSettingspageappears.
Dell Compellent
33
1 (Optional)SkipDNSconfigurationbyselectingtheSkipDNSConfigurationcheck
boxandclickingNext.TheConfigureTimeSettingspageappears.SeeConfigure
TimeSettingsonpage 35.
2 IntheDNSServersIPv4Addressesarea,specifyDNSserversthattheFluidFScluster
shouldusefornameresolution.
TodefineaDNSserver,typetheserverIPaddressinthefield,thenclickAdd.
ToremoveaDNSserver,selecttheserverIPaddress,thenclickRemove.
ToincreaseordecreasetheorderofpreferenceforaDNSserver,selecttheserverIP
address,thenclickUporDown.
3 IntheDNSSuffixesarea,specifyDNSsuffixesthattheFluidFSclustershouldusefor
nameresolution.
TodefineaDNSsuffix,typethesuffixinthefield,thenclickAdd.
ToremoveaDNSsuffix,selectthesuffix,thenclickRemove.
ToincreaseordecreasetheorderofpreferenceforaDNSsuffix,selectthesuffix,
thenclickUporDown.
4 ClickNext.TheConfigureTimeSettingspageappears.
34
1 FromtheTimeZonedropdownmenu,selectthetimezonewheretheFluidFScluster
islocated.
2 (Optional)ConfiguretheclustertosynchronizetimewithoneoremoreNTPservers.
a SelecttheUseNTPServerscheckbox.
b AddanNTPserverbytypingahostnameorIPaddressinthefieldandclicking
Add.
3 ClickNext.TheSelectStorageCenterspageappears.
Dell Compellent
35
1 SelectoneortwoStorageCenters.
2 ClickNext.
36
IftheFluidFSclusterhasFibreChannelappliances,theConnectivityReportpage
appears.SeeConfigureFibreChannelSANConnectivityonpage 37.
IftheFluidFSclusterhas10GbEiSCSIappliances,theSelectiSCSIFaultDomains
pageappears.SeeConfigureiSCSISANConnectivityonpage 39.
Dell Compellent
AllportsontheFS8600appliance(s)mustbevisibletoallStorageCentercontrollers
providingstorage.
StorageCenterinvirtualportmode:ZonesmustincludetheWWNofthePrimary
PortforeachFaultDomain(WWNzoning)orthephysicalswitchportofboththe
PrimaryandtheReserveports(portzoning).
StorageCenterinlegacymode:ZonesmustincludetheWWNoftheVirtualPort
(WWNzoning)orthephysicalswitchportsforallportsintheFaultDomain(port
zoning).
FordualcontrollerStorageCenters,eachFS8600appliancecontrollermustbeinthe
sameFCzoneswithbothStorageCentercontrollers.
37
EachFS8600appliancecontrollerportshouldhaveauniquezone.MultipleFS8600
appliancecontrollerportsshouldnotbeincludedinonelargezone.
DonotincludemultipleStorageCentersinasingleFS8600appliancecontrollerzone.If
theFluidFSclusterusestwoStorageCenters,thereshouldbeuniquezonesforeach
StorageCenterandFS8600appliancecontrollerportcombination.
1 ClickRefresh.
Ifzoningisconfiguredcorrectly,thestatusforeachportchangestoUp.
Ifzoningisconfiguredincorrectly,thestatusforoneormoreHBAsremainsDown.
Ifthishappens,verifythatthezoningconfigurationiscorrect.
2 ClickNext.TheConfigureNASPoolpageappears.SeeFinalizeFluidFSCluster
Configurationonpage 42.
38
1 SelectaStorageCenteriSCSIcontrolportforeachconnectedsubnet(StorageCenter
faultdomain).
2 ClickNext.TheConfigureIPAddressesforNASControlleriSCSIHBAspage
appears.
Dell Compellent
39
1 ConfigureiSCSIHBAIPaddressesforthefirstiSCSIsubnet(StorageCenterfault
domain).
a NexttoiSCSITargets,locatetheStorageCenteriSCSItargetIPaddresses.
b BasedontheseIPaddresses,identifytheiSCSIsubnet(StorageCenterfaultdomain).
c
IntheVLANTagfield,typetheVLANIDforthesubnet(faultdomain).
d FromtheInterfacedropdownmenu,selectthecontrollerinterfacethatisconnected
totheiSCSIsubnet.
eth30/SANistheupperrightportineachcontroller.
eth31/SANbisthelowerrightportineachcontroller.
e DefineanIPaddressforeachcontrollerbyselectingthecontroller,clickingEdit
Settings,andtypinganIPaddressinthedialogbox.
f
ClickNext.ThewizarddisplaysconnectedStorageCenteriSCSItargetIPaddresses
forthesecondiSCSIsubnetandautomaticallyselectstheunconfiguredinterface
fromtheInterfacedropdownmenu.
2 ConfigureiSCSIHBAIPaddressesforthesecondiSCSIsubnet(StorageCenterfault
domain).
a NexttoiSCSITargets,locatetheStorageCenteriSCSItargetIPaddresses.
b BasedontheseIPaddresses,identifytheiSCSIsubnet(StorageCenterfaultdomain).
c
IntheVLANTagfield,typetheVLANIDforthesubnet(faultdomain).
d DefineanIPaddressforeachcontrollerbyselectingthecontroller,clickingEdit
Settings,andtypinganIPaddressinthedialogbox.
e ClickNext.TheiSCSIportsareconfiguredandtheConnectivityReportpage
appears.
40
WhentheConnectivityReportinitiallyappears,iSCSIlogonsmightstillbe
occurringinthebackground,causingsomeoralloftheFluidFSclusteriSCSI
initiatorstoshowstatusNotFound/Disconnected.Ifthishappens,wait30seconds,
thenclickRefreshtoupdatethereport.
WhentheiSCSIlogonsarecompleteandthereporthasbeenrefreshed,thestatus
foreachFluidFSclusterinitiatorshowsstatusUp.
2 ClickNext.TheConfigureNASPoolpageappears.
Dell Compellent
41
1 IntheNASPoolSizefield,typetheamountofblockstoragetoprovideforNAS
volumesingigabytes(GB)orterabytes(TB).
Theminimumsizeis2 TB.
ForasingleStorageCenter,themaximumsizeis1024 TB.
FortwoStorageCenters,themaximumsizeis2048 TB.
Note: TheusableFluidFSNASpoolissmallerduetoFluidFSoverhead.For
example,ifasingleapplianceclusterwitha2TBpooliscreated,theactualNAS
poolisabout1.6TB(roughly400GBoverhead).
42
2 ClickNexttoprovisionandformatthecluster.
IfmultiplestoragetypesareconfiguredonaStorageCenter,theSelectstoragetype
dialogboxappears.SelectaStorageTypetoprovidestoragefortheNASpoolfrom
theStorageTypedropdownmenu,thenclickOK.
EnterpriseManagerstartsprovisioningstorage.Pagesappearindicatingthe
provisioningandformattingprocess.Whentheprocessiscomplete,theJoinActive
DirectoryDomainpageappears.
Dell Compellent
43
Prerequisites
YoumusthaveActiveDirectorycredentialswithspecificprivileges.SeeNetwork
Credentialsonpage 8.
Steps
1 (Optional)SkipActiveDirectoryconfigurationbyclickingNext.TheConfigure
ExternalUserDatabasepageappears.SeeConfigureExternalUserDatabase(NIS/
LDAP)onpage 44.
2 IntheDomainfield,typetheActiveDirectorydomain.
3 IntheUsernamefield,typeanActiveDirectoryaccountnamethathasthenecessary
privileges.
4 InthePasswordfield,typetheActiveDirectoryaccountpassword.
5 (Optional)DefinemultipleActiveDirectoryserversforredundancypurposes.
a SelecttheEnablepreferredcontrollersforjoinanduserauthenticationcheckbox.
b IntheInputDomainControllersarea,definemultipleActiveDirectoryservers.
TodefineanActiveDirectoryserver,typetheserverhostnameorIPaddressin
thefield,thenclickAdd.
ToremoveanActiveDirectoryserver,selecttheserver,thenclickRemove.
ToincreaseordecreasetheorderofpreferenceforanActiveDirectoryserver,
selecttheserver,thenclickUporDown.
6 ClickNext.TheConfigureExternalUserDatabasepageappears.
44
Toskipexternalauthentication,selectNone,thenclickNext.TheChange
AdministratorPasswordpageappears.SeeChangeAdministratorPasswordon
page 47.
TouseNetworkInformationService,selectNIS.SeeConfigureNISSettingsonpage 45.
TouseLightweightDirectoryAccessProtocol,selectLDAP.SeeConfigureLDAP
Settingsonpage 46.
1 IntheNISDomainNamefield,typeanNISdomainname.
2 IntheNISServersarea,defineoneormoreNISservers.
TodefineanNISserver,typetheserverhostnameorIPaddressinthefield,then
clickAdd.
ToremoveanNISserver,selecttheserver,thenclickRemove.
ToincreaseordecreasetheorderofpreferenceforanNISserver,selecttheserver,
thenclickUporDown.
3 ClickNext.TheChangeAdministratorPasswordpageappears.SeeChange
AdministratorPasswordonpage 47.
Dell Compellent
45
FluidFSclusterssupportsthefollowingLDAPconfigurations:
AnonymousLDAP:TheconnectionfromtheFluidFSclustertotheLDAPserver(s)is
notauthenticated.Thedataissentinplaintext.
AuthenticatedLDAP:TheconnectionfromtheFluidFSclustertotheLDAPserver(s)is
authenticatedusingausernameandpassword.Thedataissentinplaintext.
LDAPoverTLS/SSL:TheconnectionfromtheFluidFSclustertotheLDAPserver(s)is
authenticatedandencrypted.TovalidatethecertificateusedbytheLDAPserver,you
mustexporttheSSLcertificatefromtheLDAPserveranduploadittotheFluidFS
cluster.
AddingmultipleLDAPserversensurescontinuedauthenticationofclientsintheeventof
aresourceoutage.IftheFluidFSclustercannotestablishcontactwithaserver,itattempts
toconnecttotheremainingservers.
1 IntheBaseDNfield,typeanLDAPbasedistinguishednametorepresentwhereinthe
directorytobeginsearchingforusers.Itisusuallyintheformat:dc=domain, dc=com.
2 IntheLDAPServerstextfield,typethehostnameorIPaddressofanLDAPserverand
clickAdd.RepeatthisstepforanyadditionalLDAPservers.
3 IntheLDAPServersarea,defineoneormoreLDAPservers.
46
TodefineanLDAPserver,typetheserverhostnameorIPaddressinthefield,then
clickAdd.
ToremoveanLDAPserver,selecttheserver,thenclickRemove.
ToincreaseordecreasetheorderofpreferenceforanLDAPserver,selecttheserver,
thenclickUporDown.
4 (Optional)ConfiguretheremainingLDAPattributesasneeded.Theseoptionsare
describedintheonlinehelp.
ToindicatethatActiveDirectoryprovidestheLDAPdatabase,selecttheUseLDAP
onActiveDirectoryExtendedSchemacheckbox.
ToauthenticatetheconnectionfromtheFluidFSclustertotheLDAPserver,select
theUseNonAnonymousLDAPbindcheckbox.Then,typetheLDAPbind
distinguishednameusedtoauthenticatetheconnectionintheBindDNfieldand
typetheLDAPbindpasswordintheBindPasswordfield.
ToencrypttheconnectionfromtheFluidFSclustertotheLDAPserverusingTLS,
selecttheUseTLSoverLDAPcheckbox.
TovalidatethecertificateusedbytheLDAPserver,selecttheInstallLDAP
Certificatecheckbox.Then,clickUploadCertificateandselecttheLDAPSSL
certificatetouploadtotheFluidFScluster.
5 ClickNext.TheChangeAdministratorPasswordpageappears.
1 InthePasswordfield,typeapasswordfortheAdministratoraccount.
2 IntheConfirmPasswordfield,retypethepassword.
3 ClickFinish.TheFluidFSclusterisaddedtoEnterpriseManageranddisplayedonthe
Storageview.
Dell Compellent
47
48
Contents
AddDNSRecordsfortheFluidFSCluster ...................................... 49
EnableSecuredManagement ................................................. 49
VerifythatEnterpriseManagerisReceivingFluidFSEvents ....................... 52
MigrateDatatotheFluidFSCluster ............................................ 53
NextSteps .................................................................. 54
IfyouareinaroutedclientnetworkandusingmultipleclientVIPs,addallclientVIPs
totheDNSserverandassociatethemwiththesameFluidFSclustername(setup
roundrobinDNS).
IfyouareusingActiveDirectory,theDNSserversmustbethesameDNSserversthat
theActiveDirectorydomaincontrollersuse.
Dell Compellent
49
InFluidFS,theportslistedinthefollowingtabledonotparticipateinCIFS/NFS
communication,butareexposedontheclientnetworkbydefault.Enablingsecured
managementallowsyoutoexposethemanagementportsonamanagementsubnetonly.
Service
Port
WebServices
80
SecureWebServices
443
FTP
44421
FTP(Passive)
4443044439
SSH
22
EnterpriseManager
communication
35451
Securedmanagementcanbeenabledonlyafterthesystemisdeployed.Tomakeasubnet
secure:
Itmustexistpriortoenablingthesecuredmanagementfeature.
Itcanresideontheclientnetwork(subnetlevelisolationofmanagementtraffic)orthe
LOM(LightsOutManagement)Ethernetport(physicalisolationofmanagement
traffic).TheLOMEthernetportislocatedonthelowerrightsideofthebackpanelofa
NAScontroller.
Youmustloginfromthissubnet.
SelectAdmintousetheLOMEthernetportforphysicalisolationofmanagement
traffic.YoumustalsoconnectanetworkcabletotheLOMEthernetport.
SelectClientforsubnetlevelisolationofmanagementtraffic.
8 AddoneormoremanagementVIPsthroughwhichtheadministratormanagesthe
FluidFScluster.
a IntheVirtualIPv4Addressesarea,clickAdd.TheAddClientIPAddressdialog
boxappears.
b IntheIPv4Addressfield,typeamanagementVIPIPaddress.
c
50
ClickOK.
9 AddanIPaddressforeachNAScontroller.RepeatthefollowingstepsforeachNAS
controller.
a SelectaNAScontrollerandclickEditSettings.TheEditControllerIPAddress
dialogboxappears.
b IntheIPAddressfield,typeanIPaddressfortheNAScontroller.
c
ClickOK.
10 (Optional)ConfiguretheremainingFluidFSmanagementsubnetattributesasneeded.
Theseoptionsaredescribedintheonlinehelp.
Tochangethenetmaskofthenetwork,typeanetmaskintheNetmaskfield.
TospecifyaVLANtag,typeaVLANtagintheVLANTagfield.WhenaVLAN
spansmultipleswitches,theVLANtagisusedtospecifytowhichportsand
interfacestosendbroadcastpackets.
11 ClickOKtoclosetheAddFluidFSManagementSubnetdialogbox,thenclickOKto
closetheEditSettingsdialogbox.
Afterthechangetakeseffect,yourmanagementsessionwillresumeautomatically.
Managementsessionsonallothersubnetsaredisconnected.
Prerequisites
Thesubnetonwhichyouenablesecuredmanagementmustexistpriortoenablingthe
securedmanagementfeature.
Steps
1 ClicktheStorageview.
2 IntheStoragepane,selectaFluidFScluster.
3 ClicktheSummarytab.
4 Intherightpane,clickEditSettings.TheEditSettingsdialogboxappears.
5 ClicktheSecuritytab.
6 FromtheRestrictiondropdownmenu,selectRestricted.
7 ClickOK.
Dell Compellent
51
52
Inthecontextmenu,clickVolumeProperties.TheVolumePropertiesMultiple
Volumesdialogboxappears.
d ClicktheStoragetab.
e SelectLowPriority(Tier3),andthenclickOK.TheVolumePropertiesMultiple
Volumesdialogboxcloses.
2 MigratethedatafromtheexistingNASproducttotheFluidFScluster.
3 UseStorageCenterSystemManagertoconfiguretheFluidFSvolumestousethe
Recommendedstorageprofile.
a UseawebbrowsertonavigatetothehostnameormanagementIPaddressforthe
StorageCenter,thenlogon.
b IntheSystemTree,expandStorageVolumesFluidFS,thenselectthevolume
folderthatisnamedaftertheFluidFScluster.
c
Inthecontextmenu,clickVolumeProperties.TheVolumePropertiesMultiple
Volumesdialogboxappears.
d ClicktheStoragetab.
e SelectRecommended(AllTiers),andthenclickOK.TheVolumeProperties
MultipleVolumesdialogboxcloses.
Dell Compellent
53
Next Steps
Afterdeploymentiscomplete,performadditionaltaskstoconfiguretheFluidFSclusterfor
thenetworkenvironment.Thesetasksareconfigurationdependentsosomemightnot
applytoyoursite.
SeetheDellCompellentFluidFSforFS8600ApplianceAdministratorsGuidefordetailed
configurationinstructions,includinghowto:
54
CreateNASvolumes
Createnetworkshares
Createquotarules
Configureantivirusscanning
Createsnapshotschedules
ConfigureNDMPbackups
ConfigurereplicationtoaremoteFluidFScluster
Contents
Prerequisites ................................................................ 55
UpgradeStandbyControllersfromFluidFS2.0to3.0 ............................. 56
Prerequisites
Makesurethefollowingprerequisitesaremetbeforebeginningtheupgradeprocedure.
Dell Compellent
BothcontrollersintheFS8600appliancemustbepoweredoninstandbymode.
Youmusthavethefollowingmaterials:
FluidFS3.0ServicePackfile
USBflashdrivewithabout1.5GBoffreespacetoholdtheservicepackfile
USBkeyboardandVGAmonitor
55
ConnecttheUSBflashdrivetothecontroller.
d MounttheUSBflashdrivebyrunningthefollowingcommands.
[root@node0-standby~]# modprobe usb_storage
[root@node0-standby~]# mkdir /mnt/usb2
[root@node0-standby~]# mount /dev/sdc1 /mnt/usb2
e InstalltheServicePackonthecontrollerbyrunningthefollowingcommand.
[root@node0-standby~]# /mnt/usb2/DellFluidFS-3.0.[xxx]-SP.sh -stand
-nocheck
Note: Multiplerebootscanoccurduringtheinstallationprocess.Donot
disturbthecontrolleruntiltheloginpromptappears.
3 RepeatStep 2toreimagecontroller1.
56
Contents
DellPowerConnectiSCSISwitchConfiguration ................................. 57
Dell Compellent
57
vlan 99
name "FS8600_Internal"
exit
vlan 118
name "iSCSI_118_SAN_A"
exit
configure
interface range Te1/0/13,Te1/0/14
spanning-tree portfast
mtu 9216
switchport mode general
switchport general pvid 99
switchport general allowed vlan add 99
switchport general allowed vlan add 118 tagged
exit
configure
interface range Te1/0/17,Te1/0/18
spanning-tree portfast
mtu 9216
switchport access vlan 118
exit
configure
interface range Te1/0/2
mtu 9216
switchport mode general
switchport general pvid 99
switchport general allowed vlan add 99
exit
58
name "iSCSI_119_SAN_B"
exit
configure
interface range Te1/0/13,Te1/0/14
spanning-tree portfast
mtu 9216
switchport mode general
switchport general pvid 99
switchport general allowed vlan add 99
switchport general allowed vlan add 119 tagged
exit
configure
interface range Te1/0/17,Te1/0/18
spanning-tree portfast
mtu 9216
switchport access vlan 119
exit
configure
interface range Te1/0/23
mtu 9216
switchport mode general
switchport general pvid 99
switchport general allowed vlan add 99
exit
Dell Compellent
59
60
690-047-002 B