Sie sind auf Seite 1von 4
Designation: A 421/A 421M — 02 Standard Specification for Uncoated Stress-Relieved Steel Wire for Prestressed Concrete’ Toe sanud ene amet ection A218 42)M sh minima fli i dos ine eye fecal sapon em coe er oe hn nnn prc ta at 8 ha aga ‘A sapenp cre fe ees an soma ehuge sce the bot eon oe sandr hs Baw roomed fr ane Aegon ofthe pant a ie 1, Scope* 1.1 This specification covers twve types of uncented sireas- relieved round high-carbon tec! wite commonly used in prestressed linear conerete eonsteuctfon, as follows: Ld Type BA wiee is wsed for applications in whieh cold end deformation is used for anchoring purposes (Button Anchorage), and 1.1.2 Daye INA wite is used for application in whiel the ends are auchored by wedges, and no cold-end deformation of the wire is involved {Wedge Anchorage. 1.2 Supplement | deseribes low telaxation wine and relax ation testing for thor preduct. 13 The values stated in either ineh-pound or SI units are 19 be regarded as standard. Within the txt, io inch-pound wnt are shown in parentheses. The veluos stated in ese system are not exact equivalents; therefore, each system shall be used independently of the ether, without combining values in any way. 2. Referenced Documents 2.1 ASTM Standards: ‘6.370 Test Methods and Definitions for Mechanical Testing of Steel Products? 1.30 Test Mcthods for Chemical Analysis of St Iton, Open-Hearth Iron, and Wrought Iron? £328 Methods for Sioss Relaxation Tosts for Materials and Struciurest 22. Miltary Standards: MIL-STD-129 Marking for Shipment and Storoge* MIL-STD-163 Steel Mill Products, Preparation for Shipe rent and Storage? | Cast "hes pecs oder the nsdn of ASTM Conmaee ADI om Si Coren eli apyroved Se 10, 260, Pudi Jose 3008. Onan ibis a 4421 “Sk aspen dion 421 Sha dia Bok of TAS Stand Yo 0. Diecsitined ee 1998 tel Bat of ASTM Stony YO 0S “tek of S734 Senda, 9020) * Svan Sucre Bacareis re ig. 4 Sco . 70 obi Ave Pies: PQ TPHTESID4 ihe PODS 3 ederal Standard Fed, Si, No. 123 Marking for Shipments (Civil Agencies)* 3. Ordering Information 3.1 Onvers for steess-relieved wire ender this specification should include the following information: 3.1.1 Quantity (ke Mbp. 3.12 Diameter, 3.1.3 Type of anchorage (BA or WA}, 3.14 Packaging, 3.1.5 ASTM designation and date of issue, and 3.1.6 Special requirements, if any. Now £- A uploa ordering desertion ie a Sllows: 10-000 ky of 6384 hansen ee, pe HA approximate 48D ky Som dismeter soils fo ASTM ASZEA SIM 2 000 Th 0.2504. dismeter ‘site, Tye BA ix epproxinalely 1600 Th in. diameter coils to ASTM, ASLAM. ? 4. Manufacture 4,1. Process—The stvel shall be made by the basie-oxyyen, open-hearth, or electei-tumace process. 42 Inernal Sonndness—A solficient discard shali be made te ensure freedom from injurious piping znd undue sogrega- tion, 4.3. Wire—The wire sil be cold-dlrawn to size and suitably stress relieved after cold drawing by a continuows heat treat- ‘meat to predace the preseribed mechanical properties. 5. Physical Requirements 5.)_ Teasite Strengeh-The tonsile strength of Type BA wire and Type WA wire shall conform co the requirements pre- seribad in Table 1, and shall be desermized as proseribed i Test Methods and Definitions A 370, including Annee Ad, 3.2. Teel Strenaih 5.2.1. The minimum yield steenath forall wire, measured by the 1.0% extension under losd method, shall not be lass than 85% of the specified minimum breaking strength, 5.2.2 The extension under load sball be messured by am extensometer calibrated with the smallest division not larger tia 0.0001 muvinm (0.0001 insin.) of gage length. 4 Sammary of Change section apponrs atthe end of this standard Cire ©AST norte, 9B Har int PB CR We Coane, PA AIR ID Uns Se Aly a 42tsA 421M - 02 TABLE 1 Tensile Strength Requirements ‘Nomina ameter nm “Tenet Seng, min MPa @ Tee BA Tipe WA a8 10) = "725 50 oon) 95,0 196) 3635 20 000) 1735 (280 00) 35 0.250) 1055 240000) 1885 (2e0 070) por eare) 43620235 000) 120 (238 000) 5.23 The initial load corresponding to the initial stress prescribed in Table 2 shall be applied to the specimen, at which time the extensometer is atached and adjusted to a reading of 0.001 mnvmm (0.001 inJin.) of gage length. The load shall, then be increased until the extensometer indicates an extension, ‘of 1 %, The load for this extension shall be recorded. The stress corresponding 0 this load shall mect the requirements for sess at | 96 extension preseribed in Table 2. $3 Elongation—The total elongation under load ofall wire shall not be less than 4.0 % when measured in a gage lengti of 250 mm (10 in.). The elongation shall be determined by an ‘extensometer which is placed on the test specimen after a load corresponding 0 the initial stress prescribed in Table 2 is Applied. Ifthe fracture takes place outside of the gage length, the elongation value obtained may not be representative of the material, Ifthe clongation so measured meets the minimum requirements specified, no further testing is indicated; but if the

Das könnte Ihnen auch gefallen