Sie sind auf Seite 1von 1

represented by:

measurIT technologies

Thermal Energy Measurement for District Energy

FLEXIM's Thermal Energy Meter with WaveInjector® on high temperature hot water lines provides for an
accurate, reliable and "maintenance free" thermal energy metering solution.

Measuring task Method Medium

? Energy measurement Ultrasound Hot water

Features Measuring Task………………………………………..


Medium: water at ~ 180°C (360°F) Flow measurement at very high temperatures encounters three
Pipe: 3CS40 specific problems: signal drift, drying out of the couplant grease
between the transducer and pipe, and premature failure of the
Material: carbon steel
transducers because of thermal breakdown.
Instrument: BTU meter
An ultrasonic meter from another supplier was already installed for
superheated hot water metering and was plagued with both
measuring values drift and high failure rates. The failure led to data
and hence accountability losses. A reliable solution was sought for
the metering.

Solution….……………………………………………...
FLEXIM patented WaveInjector® together with FLUXUS' stable zero
balance flowmeters is an ideal solution for this measuring task. It
can be used at extreme temperatures as high as 400°C (700°F). No
pipe work is needed to install the measurement, and no
maintenance is required
The WaveInjector® removes the transducers from the hot pipe. It
incorporates solid coupling materials and thus eliminates thermal
breakdown.

Advantages...…………………………………………..
The traditional mounting method for ultrasonic Use of standard transducers at temperatures as high as 400°C
flow transducers is unable to keep the (700°F)
transducers coupled to the pipe. The couplant
just drips off the pipes as seen here, leaving the Measurement is insensitive to temperature changes
meter helpless to process energy and flow
measurement. No pipe work needed to install the system
No maintenance needed
Real time energy calculations
Solid couplant instead of grease - no need to re-couple
transducers
Internal data logging capabilites with easy data retrieval

FLEXIM's WaveInjector® is the solution to the


problems encountered at high temperatures

MeasurIT Technologies Ltd.


Craan, Craanford, email: info@measurIT.com Phone: +353 (0) 53 942 8962
Gorey, Co. Wexford, Ireland www.measurIT.com Fax: +353 (0) 53 942 8963