Sie sind auf Seite 1von 20

4G Transmission Design

Ericsson RAN
A Wilding
24th June 2013

Transmission Design
4/25/16

Confidentiality level on title master


Version number on title master

Contents
1. 4G
1.
2.
3.
4.
5.
6.
7.
8.
9.

4G & Beacon Physical Connection


4G IP-Sec Tunnel Connections
4G VRFs with IP-Sec
Mocn 4G RBS IP-addressing, one in-service DUL with IP-Sec (Rel13A)
Mocn 4G RBS IP-Sec Tunnels, one in-service DUL (Rel13A)
Moran 4G RBS IP-addressing, two DUL with IP-Sec (Rel13B)
Moran 4G RBS IP-Sec Tunnels, two DUL (Rel13B)
4G RBS IP-addressing, two DUL without IP-Sec
4G VRFs without IP-Sec

2. Beacon 2G and 3G
10. Beacon 2G and 3G VRFs
11. Beacon RBS 2G and 3G IP-addressing

3. Beacon 2G, 3G and 4G Requirements


12.
13.
14.
15.
16.
2

Beacon RBS Synchronisation distribution


Beacon 2G, 3G and 4G RBS IP-addressing Requirements
Vf 4G MTX IP-addressing Requirements
Beacon 2G, 3G and 4G RBS VLAN Requirements
Beacon 2G, 3G and 4G Access Network VLAN Requirements
Presentation title in footer
4/25/16

Confidentiality level on slide master


Version number on slide master

4G & Beacon Physical Connections


MTX A

BEP 1.0
8660

CPN

ASR9000

ASR9000

BSC
CSG
OSS-RC

Access Network

RNC
Firewall

RBS6000
ASR9000

Sec-GW

CPN

ASR9000

BEP 1.0
8660
The Cell Site Gateway, CSG, can be
one of the following:
C&W 8605
BEP 1.0: 8630 or 8660
BT 8605 (layer 2)
BEP 2.0: A2200 or FP800 (layer 2)

Ericsson 4G Transmission Design


4/25/16

P/S-GW

SSU 2000:
PTP Grand
Master

Tef EPC
Sec-GW
MME

Confidentiality level on slide master


Version number on slide master

EPC

MME

MTX B

4G & Beacon physical connections, 4G only encrypted


MTX A
BEP 1.0

8660

CPN

ASR9000
BSC

8630
CSG
Non-Beacon
RNC

Access Network
(BT, CWW, BEP 2.0)

OSS-RC MTX
Beacon
RNC
Firewall

BEP 1.0
Sec-GW

RBS6000

CPN

ASR9000

8630
8660

P/S-GW

ASR9000

EPC

Telefonica
MTX

Sec-GW

Tef CPN

Huawei 4G Beacon Transmission Design Confidentiality level on slide master


Version number on slide master
4/25/16

MME

Tef
EPC

MME

4G IP-Sec Tunnel Connections


MTX A

BEP 1.0
8660

CPN

ASR9000

ASR9000

BSC
CSG
OSS-RC

Access Network
VVff 44G
G SS11,, X
X22 && OA
OAM
M

&
SS11 &

XX22

The Cell Site Gateway, CSG, can be


one of the following:
C&W 8605
BEP 1.0: 8630 or 8660
BT 8605 (layer 2)
BEP 2.0: A2200 or FP800 (layer 2)

Ericsson 4G Transmission Design


4/25/16

Firewall
ASR9000

G
4G
TTeeff 4

RBS6000

RNC

Sec-GW

CPN

BEP 1.0
8660

ASR9000

P/S-GW

Tef EPC
Sec-GW
MME

Confidentiality level on slide master


Version number on slide master

EPC

MME

MTX B

4G VRFs with IP-Sec


BEP 1.0
8660

MTX A

SSU 2000 GMs

CPN
ASR9000

ASR9000

RBS6000

Access
Network

OSS-RC

IP_E
_Ac
ces
s_4
G_V
f (S
IP_E
1, X
_Ac
2&
cess
OAM
_4G
(S1
)
_Te
&X
f
2)

RNC

ASR9000
RAN_Encrypt

Ericsson 4G Transmission Design


4/25/16

CPN

EF
_T

The Cell Site Gateway, CSG, can be


one of the following:
ITN 901
BEP 1.0 8605 for CWW EWL
BEP 1.0: 8630 or 8660
BT 8605 (layer 2)
BEP 2.0: A2200 or FP800 (layer 2)

AN
R

BEP 1.0
8660

Tef CPN
Sec-GW
MME

Confidentiality level on slide master


Version number on slide master

Firewall
CH
M
O
AN_
Sec-GWR OAM)ASR9000
(4G

4G
_S
1

CSG

BSC

P)
PT
(
nc
Sy

EPC

P/S-GW

MME

MTX B

Mocn 4G RBS IP-addressing, one in-service DUL with


IP-Sec (Rel13A)
SSU 2000:
PTP GM

RBS 6000
Vf DUL
MP
x.x.x.0/31 y.y.y.6
x.x.x.1/31

d.d.d.66

SIU/TCU
510

Access
Network

y.y.y.5

y.y.y.4/30

y.y.y.2

NPU

R
Tef DUL
y.y.y.10
511
MP
x.x.x.2/31
y.y.y.8/30

BEP 1.0
86xx

y.y.z.2
d.d.d.2

500: y.y.y.0/30

d.d.d.64/30
d.d.d.65

BEP 1.0
8660

y.y.y.1

600: y.y.z.0/30

y.y.z.1

1588: d.d.d.0/30

d.d.d.1

BEP 1.0
IP Access
ASR9000

y.y.y.9

x.x.x.m/32
EPC

NPU

MME

y.y.y.gw/32
Sec-GW

OAM
CP/UP (S1 & X2)

Tef EPC

CPN

OAM service will be between x.x.x.0 & x.x.x.om, and x.x.x.2 & x.x.x.om
Sec-GW
z.z.z.gw/32
MME
Vf S1 & X2 CP/UP service to MME will be between x.x.x.1 and x.x.x.m
z.z.z.m/32
Tef S1 CP/UP service to their MME will be between x.x.x.1 and z.z.z.m
x.x.x.0 and x.x.x.1 are from the same /31: x.x.x.0: even address, x.x.x.1: odd address
x.x.x.om/32
The Vf and Tef S1 (& X2) services both use the same inner and outer IP-address on the Vf DUL
OSS-RC
PTP service will not be encrypted and will be between y.y.y.6 and d.d.d.66 via VLANs 510 and 1588.
7

Ericsson 4G Transmission Design


4/25/16

Confidentiality level on slide master


Version number on slide master

P/S-GW

Mocn 4G RBS IP-Sec Tunnels, one in-service DUL


(Rel13A)
RBS 6000
Vf DUL
MP
x.x.x.0/31 y.y.y.6
x.x.x.1/31

SIU/TCU
510
y.y.y.4/30

y.y.z.2

BEP 1.0
8660

y.y.y.1

y.y.y.2

NPU

Tef DUL
y.y.y.10
511
MP
x.x.x.2/31
y.y.y.8/30

BEP 1.0
86xx

Access
Network

y.y.y.5

SSU 2000:
PTP GM

500: y.y.y.0/30
600: y.y.z.0/30

y.y.z.1

BEP 1.0
IP Access

ASR9000

y.y.y.9

x.x.x.m/32
EPC

NPU

y.y.y.gw/32

MME

Sec-GW

OAM
CP/UP (S1 & X2)

Tef EPC

Vf IP-Sec Tunnel
Tef IP-Sec Tunnel

CPN
Sec-GW

MME

z.z.z.gw/32

z.z.z.m/32
Vf 4G S1, X2 & OAM IP-Sec Tunnel will be between y.y.y.6 & y.y.y.gw,
Vf 4G OAM IP-Sec Tunnel for the Tef DUL will be between y.y.y.10 & y.y.y.gw
x.x.x.om/32
Tef 4G S1 IP-Sec Tunnel will be between y.y.y.6 and z.z.z.gw
OSS-RC
The Vf and Tef IP-Sec tunnels to the in-service DUL use the same outer IP-address on the DUL
8

Ericsson 4G Transmission Design


4/25/16

Confidentiality level on slide master


Version number on slide master

P/S-GW

Moran 4G RBS IP-addressing, two DUL with IP-Sec


(Rel13B)
SSU 2000:
PTP GM

RBS 6000
Vf DUL
MP
x.x.x.0/31 y.y.y.6

SIU/TCU
510

y.y.y.2

NPU

R
Tef DUL
y.y.y.10
511
MP
x.x.x.2/31
y.y.y.8/30
z.z.z.2
x.x.x.3/31

NPU

610

BEP 1.0
86xx

y.y.y.5

y.y.y.4/30

x.x.x.1/31

d.d.d.66

y.y.z.2
d.d.d.2

Access
Network
500: y.y.y.0/30
600: y.y.z.0/30
1588: d.d.d.0/30

y.y.y.1
y.y.z.1

d.d.d.64/30
d.d.d.65

BEP 1.0
8660

BEP 1.0
IP Access

d.d.d.1

ASR9000

y.y.y.9

x.x.x.m/32
EPC

z.z.z.1

z.z.z.0/30

MME

y.y.y.gw/32
Sec-GW

OAM

CP/UP (S1 & X2)

Tef EPC

CPN

OAM service will be between x.x.x.0 & x.x.x.om, and x.x.x.2 & x.x.x.om
z.z.z.m/32
Sec-GW
Vf CP/UP service to MME will be between x.x.x.1 and x.x.x.m
z.z.z.gw/32
Tef CP/UP service to MME will be between x.x.x.3 and z.z.z.m
MME
z.z.z.0/30, z.z.z.gw/32 and z.z.z.m/32 are IP-addresses allocated by Telefonica
x.x.x.0 and x.x.x.1 are from the same /31: x.x.x.0: even address, x.x.x.1: odd address
x.x.x.om/32
x.x.x.2 and x.x.x.3 are from a shared /31: x.x.x.2: even address to Vf; x.x.x.3: odd address to Tef
OSS-RC
PTP service will not be encrypted and will be between y.y.y.6 and d.d.d.66 via VLANs 510 and 1588.
9

Ericsson 4G Transmission Design


4/25/16

Confidentiality level on slide master


Version number on slide master

P/S-GW

Moran 4G RBS IP-Sec Tunnels, two DUL (Rel13B)


RBS 6000
Vf DUL
MP
x.x.x.0/32 y.y.y.6

SIU/TCU
510

x.x.x.1/32

y.y.y.2

NPU

R
Tef DUL
y.y.y.10
511
MP
x.x.x.2/31
y.y.y.8/30
z.z.z.2
x.x.x.3/31
1

NPU

610

BEP 1.0
86xx

y.y.y.5

y.y.y.4/30

y.y.z.2

SSU 2000:
PTP GM

Access
Network
500: y.y.y.0/30
600: y.y.z.0/30

BEP 1.0
8660

y.y.y.1
y.y.z.1

BEP 1.0
IP Access

ASR9000

y.y.y.9

x.x.x.m/32
EPC

z.z.z.1

z.z.z.0/30

y.y.y.gw/32

MME

Sec-GW

OAM
CP/UP (S1 & X2)

Tef EPC

Vf IP-Sec Tunnel
Tef IP-Sec Tunnel

CPN
Sec-GW

MME

z.z.z.gw/32

z.z.z.m/32
Vf 4G S1, X2 & OAM IP-Sec Tunnel will be between y.y.y.6 & y.y.y.gw,
Vf 4G OAM IP-Sec Tunnel for the Tef DUL will be between y.y.y.10 & y.y.y.gw
Tef 4G IP-Sec Tunnel will be between z.z.z.2 and z.z.z.gw
10

Ericsson 4G Transmission Design


4/25/16

Confidentiality level on slide master


Version number on slide master

x.x.x.om/32

OSS-RC

P/S-GW

4G RBS IP-addressing, two DUL without IP-Sec


(Bespoke designs for Padd and Newbury)
SSU 2000:
PTP GM

RBS 6000
Vf DUL
y.y.y.6
MP

d.d.d.66

SIU/TCU

501
y.y.y.4/30

NPU

x.x.x.2
510 x.x.x.1
x.x.x.0/30

x.x.x.2

R
Tef DUL
y.y.y.10
511
MP
y.y.y.8/30
z.z.z.2

NPU

610

BEP 1.0
86xx

y.y.y.5

y.y.y.2
y.y.z.2
d.d.d.2

Access
Network
500: x.x.x.0/30
550: y.y.y.0/30
600: y.y.z.0/30
1588: d.d.d.0/30

d.d.d.64/30
d.d.d.65

x.x.x.1
y.y.y.1

BEP 1.0
8660

BEP 1.0
IP Access

y.y.z.1
d.d.d.1

ASR9000

y.y.y.9

x.x.x.m/32
EPC

z.z.z.1

z.z.z.0/30

MME

OAM
CP/UP (S1 & X2)

Tef EPC

OAM service will be between y.y.y.6 & y.y.y.om, and y.y.y.10 & y.y.y.om
Vf CP/UP service to MME will be between x.x.x.2 and x.x.x.m
MME
z.z.z.m/32
Tef CP/UP service to MME will be between z.z.z.2 and z.z.z.m
z.z.z.0/30 and z.z.z.m/31 are IP-addresses allocated by Telefonica
PTP service will be between x.x.x.2 and d.d.d.66 via VLANs 510 and 1588.
If only one DUL, sync to SIU can be SyncE and sync to DUL can be 1pps via GPS_Port.
11

Ericsson 4G Transmission Design


4/25/16

CPN

Confidentiality level on slide master


Version number on slide master

y.y.y.om/32

OSS-RC

P/S-GW

4G VRFs without IP-Sec


Vodafone MTX

OSS-RC

SSU
CSG

Access
Network
RBS6000

TP)
c (P
Syn
IP_E_Access_4G
_Vf_MTX
IP_E_Access_4G
8660
_Tef_MTX

BEP 1.0

Firewall

CH
RAN_OM

)
(4G OAM

ASR9000

CPN
RA
N_
Tef

S1
4G_

ASR9000
P/S-GW

EPC

MME

Telefonica MTX
Sec-GW

The Cell Site Gateway, CSG, can be


one of the following:
C&W 8605
BEP 1.0: 8630 or 8660
BT 8605 (layer 2)
BEP 2.0: A2200 or FP800 (layer 2)

12

Ericsson 4G Transmission Design


4/25/16

Tef CPN

Confidentiality level on slide master


Version number on slide master

MME

Tef
EPC

Beacon 2G and 3G VRFs


MTX A

BEP 1.0
8660

CPN
RAN_UNencrypt

CSG

is)
(Ab
X
_MT
_2G
s
s
c ce
E_A
_
P
I

ASR9000

ASR9000

BSC

Access Network

MTX B

RNC

RBS6000

IP_E_
Acce
ss_3G
_Iub_
IP_E
MTX
_Acc
ess_
3G_O
AM_M
TX

BEP 1.0
8660

encrypt
RAN_Un
RA
N_
OM
CH

Firewall

The Cell Site Gateway, CSG, can be


one of the following:
C&W 8605
BEP 1.0: 8630 or 8660
BT 8605 (layer 2)
BEP 2.0: A2200 or FP800 (layer 2)

13

Ericsson 4G Transmission Design


4/25/16

Sec-GW

OSS-RC

Confidentiality level on slide master


Version number on slide master

CPN

ASR9000

Beacon RBS 2G and 3G IP-addressing


RBS 6000
DUW1
a.a.a.6
b.b.b.6

SIU/TCU
a.a.a.5

110 : a.a.a.4/30
210 : b.b.b.4/30

a.a.a.2
b.b.b.2

b.b.b.5

R
DUW2
a.a.a.10
b.b.b.10

c.c.c.2

Access
Network
100: a.a.a.0/30
200: b.b.b.0/30
400: c.c.c.0/30

BEP 86xx,
CWW CSG
a.a.a.1
b.b.b.1
c.c.c.1

a.a.a.9

111 : a.a.a.8/30

c.c.c.4/32

211 : b.b.b.8/30

b.b.b.9

IP-Sec available on 2G from Rel T14A


(Jan 2014)
IP-Sec available on 3G from Rel 14B
(June 2014) planned release, not
committed

3G OAM
3G Iub
2G Abis

All Physical connections shown are 1000BaseT


In Larger sites a third DUW will be directly connected to the SIU and use VLANs 112 and 212.
If required a further DUW will be cascaded via 1000BaseT from one of the existing DUWs.
2G DUGs Traffic and Sync will be via 2xE1s per DUG from the SIU; Packet Abis terminates on the SIU.
SIU OAM will use the 3G OAM address: a.a.a.2, and will route with the 3G OAM traffic to OMCH VRF.

14

Ericsson 4G Transmission Design


4/25/16

Confidentiality level on slide master


Version number on slide master

Beacon RBS Synchronisation distribution


RBS 6000

DUG

SIU/TCU

CSG
SyncE

DUW

DUW
Access
Network

Vf DUL

Tef DUL

Synchronisation input to the SIU is SyncE from the CSG.


Sync distribution to the 3G DUW will be via E1, whilst traffic is 1000BaseT.
Traffic and Sync distribution to the 2G DUGs will be via E1s from the SIU.
Synchronisation to the Vf 4G DUL will be 1588v2 from Grand Masters in the MTX.
Synchronisation to the Tef DUL will be distributed from the Vf DUL via 1pps using the GPS ports
If two DUs share the same radio then sync between the DUs via 1pps using the GPS ports is required

15

Ericsson 4G Transmission Design


4/25/16

Confidentiality level on slide master


Version number on slide master

SSU 2000
GMs

E1
1000BaseT
1pps
PTP: 1588v2

Beacon 2G, 3G and 4G RBS IP-addressing


Requirements
External address between TCU/SIU and
Transport network

External address between TCU/SIU and


3G DUWs

Five Vf /30s for PTP, 2G, 3G and 4G


services, and one Vf /30 for Tef 4G traffic:

There will be two directly connected DUWs in a


large site, and two cascaded

PTP (1588v2 synchronisation over packet)


2G
3G OAM (including SIU OAM)
3G Iub
Vf 4G (S1, X2, OAM)
Tef 4G (S1 X2)

One /30 for Iub per directly connected DUW


One /30 for OAM per directly connected DUW

Internal addresses on TCU/SIU


One Vf /32 to terminate packet Abis
Note that the SIU/TCU OAM uses the 3G OAM external /30
interface address

Addresses between TCU/SIU and 4G DUL


Configuration supporting two DULs, one for
Vodafone and one for Telefonica, will require:
One Vf /30 for S1, X2, OAM and PTP for the Vf DUL
One Vf /30 for OAM for the Tef DUL
One Tef /30 for S1/X2 for the Tef DUL
Note that each DUL supports both L800 and L2600

Internal addresses on DUL


Configuration supporting two DULs, one for
Vodafone and one for Telefonica, will require:
One Vf /31 for the Vf DUL (for OAM (even) and S1/X2 (odd))
One shared /31 for the Tef DUL (even address = OAM to Vf;
odd address = S1/X2 to Tef) (*)
(*) alternative design for the Tef DUL Internal addresses:
One Vf /31 for the Tef DUL OAM
One Tef /31 for the Tef DUL S1/X2

16

Ericsson 4G Transmission Design


4/25/16

Confidentiality level on slide master


Version number on slide master

Vf 4G MTX IP-addressing Requirements


Internal /32 addresses required for
Vf in the MTX
1x /32 per tunnel on Sec-GW
1x /32 on MME
1x /32 on OSS-RC
External /30 addresses required for
Vf in the MTX
1x /30 between BEP 1.0 8660 and
SSU 2000 PTP GM

17

Ericsson 4G Transmission Design


4/25/16

Confidentiality level on slide master


Version number on slide master

Beacon 2G, 3G and 4G RBS VLAN Requirements


VLANs between the RBS and the CSE
3G OAM 100
3G Iub 200
2G 400
4G Access (carries S1, X2 & OAM) 500
4G Access CP/UP Tef (carries S1 & X2) 600
PTP 1588

18

Ericsson 4G Transmission Design


4/25/16

Confidentiality level on slide master


Version number on slide master

Beacon 2G, 3G and 4G Access Network VLAN


Requirements
Customer VLANs across BT and BEP 2.0
3G OAM odd numbers starting from 1 (range 1 999)
3G Iub even numbers starting from 2 (range 2 1000)
2G sequential numbers, range 2001 - 2400
PTP C&W CSG sequential numbers, range 2401 - 2700
PTP E/// eNodeB sequential numbers, range 2701 - 3000
BEP 2.0 DCN range 3001 - 3100
Vf 4G 3101 3700
Tef 4G 3701 4000
C&W Service VLANs
C&W Service sequential numbers, range 1001 1400
C&W Redundant Path sequential numbers, range 2001 2400

19

Ericsson 4G Transmission Design


4/25/16

Confidentiality level on slide master


Version number on slide master

Not Covered in this Presentation


S1-flex

Pre-requisites
XPIC deployment in BEP 1.0 Microwave Rings

20

Ericsson 4G Transmission Design


4/25/16

Confidentiality level on slide master


Version number on slide master

Das könnte Ihnen auch gefallen