Sie sind auf Seite 1von 4

PYRAN\\O

Ciold )czriC!)
REGULATED DC
POWER SlTPPLY
MODEL: PS-3KX/4KX/7KX/SKX

INSTRUCTION MANUAL

GENERAL

S PE CIFICATION

SCHEMATIC

DIAGRAM

OPERATION MANUAL & CAUTION

PAGE 2
PAGE 3
PAGE 4

GENERAL SPECIFICATIONS.

ELECTRICAL:
PS-3KX

MODEL NO.:

PS-4KX

PX-7KX

PS8KX

YES

(A-l) INPUT RATING.


INPUT VOLTAGE: 10S125VAC(11SV NORMAL).

YES

YES

YES

INPUT LINE FREQUENCY: 60Hz.

YES

YES

YES

YES

INPUT POWER: MAX.

SOW

SOW

70W

l00W

(A-2) OUTPUT RATING.


YES

YES

YES

YES

2/3A

3/4A

517A

6/SA

YES

YES

YES

YES

.YE:S

.YES

YES

.YES

OUTPUT VOLTAGE 13.8VDC O.3V


OUTPUT CURRENT: CONT/MAX
OUTPUT RIPPLE: lS0mV RMS

(SEE -NOTE')

(A-3) REGULATION.
LOAD REGULATION: 2.S%(280mV P.P)MAX.
(A-4) PROTECTION.
INPUT LINE PROTECTION: GLASS TUBE FUSE 1.5A12S0V 1.0Al2S0V 15A/250V 1.SAl250V
OVER-LOAD PROTECTION: +10%

-15%

(AUTO

3A

RESET)
Ov'ER TEMPERATURE PROTECTIOO
(A-5) EFFICIENCY:60% MIN. (SEE .NOTE)

4A

7A

SA

YES

YES

YES

YES

YES

YES

(A-6) DESIGN LINEAR TYPE.


(A-7) OPERATING TEMPERATURE 0 TO +40 DEG C.
(A-8) STORAGE TEMPERATURE: - 2S TO +70 DEG C.

NOTE: INPUT AT 115VAC AND OUTPUT AT CONT. CURRENT

MECHANICAL:
(B-1) DIMENSIONS

19Omm)( 125mm)(

76mm.

(lxWx H)

(B-2) WEIGHT KGS


(B-3) ENCLOSURE

8LACK

(B-4) INPUT CABLE 18AWGx2C W/l15P PLUG

I. 7 KGS

18KGS

2lKGS

2.5KGS

YES

YES

YES

YES

SPT-26FT SPT26FT SPT-2 6FT SPT2 6FT

(B-S) OUTPUT TERMINAL: BINDING POST, 10Al125V

YES

YES

YES

YES

(8-6) POWER SWITCH ILLUMINATED, 1 5A112SVAC

YES

YES

YES

YES

-2-

CIRCUIT DIAGRAM PS3KX/4KX/7KX/8KX


F1

FUSE
PS3KX
PS4KX
PS7KX
INPUT PS8KX
AC 115V 60Hz

T1

D1 IN5402

lA
1A
l.5A
1.5A

Q! 2N3()55

OUTPUT
DC 13.8V

(.oJ

D6
IN4148

II

[K.

D7
IN4148

CIRCUIT ARE SUBJEcr TO CHANGE WITHOUT NOTICE

OPE RATION:
AC POWER PLuG INTO A

IIOV VOLT

AC OUTLET.

INSERT

CONNECT THE POWER CORD OF YOUR EQUIPMENT (13.5V - 14 1VDC) TO THE


OUTPUT BINDING POST TERMINALS ON THE FRONT OF THE UNIT BE SURE THAT
POLARITY IS CORRECT. THE RED POSITIVE (+) TERMINAL AND BLACK NEGATIVE
(-) TERMINAL ARE MARKED. REVERSAL OF POLARITY. MAY DAMAGE YOUR
EQUIPMENT.

TURN SWITCH TO "ON". RED LIGHT IN SWITCH WILL ILLUMINAfE

THE INPUT POWER IS PROTECTED BY THE FUSE WHICH IS LOCATED AT THE REAR
OF THE UNIT AND CAN BE REPLACED BY UNSCREWING THE FUSE HOLDER IF THE
FUSE IS BURNT OUT. DO NOT USE A FUSE LARGER THAN
HEAVIER FUSE MAY RESULT IN DAMAGING TO THIS UNIT

5.

AMPS USE OF

SEE NOTE)

THIS UNIT HAS ELECTRONIC OVERLOAD PROTECTION WITH INSTANT AUTOMATIC


RESET FUNCTION

IF OUTPUT IS OVERLOADED. THE OUTPUT POWER WILL

AUTOMATICALLY SHUT OFF. RELEASE POWER CORD Of YOUR EQUIPMENT FROM


THE OUTPUT TERMINALS AND CHECK THE ACTUAL POWER RATING OF YOUR
EQUIPMENT. THIS UNIT
6.

OVER TEM PERATURE


TO

PREVENT

OVER

WILL AUTOMATICALLY RESET INSTANTLY


PROTECTI ON CIRCUITRY

HEAT DAMAGE UNIT

WI LL

IS USED IN

PS-7KX/BKX

BE SHUT DOWN

15 MINUTES( M IN. ) AT 100% RATED LOAD.


25 MINU TES( MIN.) AT 00% RATED LOAD.
1. 5 AM P
1 0 AMP
1-5 AMP
1.5 AMP

MIN UTES AFTER

NOTE

PS-3KX:
PS-4KX :
PS-7KX:
PS-SKX :

CAUTIONS:
1

DO NOT USE WITH EQUIPMENT REQUIRING MORE THAN RATING AMPS

DO NOT USE OUTDOORS. DO NOT EXPOSE UNIT TO RAIN. MOISTURE. WATER OR

DO NOT REMOVE COVER IN ANY CASE. RETURN TO DEALER FOR REPAIR IF

ANY OTHER LIQUIDS


DAMAGED.
4.

THIS UNIT HAS A SPECIAL BUILT-IN FEATURE THAT WILL SHUT THE UNIT OOWN
IF MARKED AMPERAGE IS EXCEEDED. THIS WILL AVOID BURN-OUT OF YOUR
EQUIPMENT AND OF UNIT. IF UNIT DOES CONSISTENTLY SHUTDOWN. THIS MEANS
YOU ARE DRAWING TOO MUCH AMPERAGE.

RETURN UNIT TO PLACE OF

PURCHASE AND UPGRADE TO NEXT AVAILABLE UNIT OFFERING HIGHER


AMPERAGE. PLEASE DO NOT BYPASS OR ALTER THIS CIRCUIT AS IT IS THERE
TO PROTECT YOU. ANY ALTERATION OR MISUSE WILL VOID YOUR WARRANTY.

"DANGER"
HIGH VOLTAGE
REFER TO QUALIFIED TECHNICIAN FOR SERVICE_

-4-

Das könnte Ihnen auch gefallen