PASOLINK PNMS Cable
1. PASOLINK LCT Cable

Station B

Station A

PASOLINK
NMS Port

PASOLINK

LA Port

182-228614
LCT
LCT

Figure 1 LA port - LCT(PC) connection

15pin(M)

9 pin(F)

Paso
LA
Connector

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

RS-232C
LCT-TXD
GND
LCT-RXD
LCT-RTS
LCT-CTS
GND
PNMT-CTS
PNMT-RTS
PNMT-RXD
GND
PNMT-TXD

PC(LCT)

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
5
6
7
8
9

1
2
3
4
5
6
7
8
9

CD
RD
TD
DTR
GND
DSR
RTS
CTS
RI

PC(LCT)

(182-228614)
Figure 2 Pin assignment for LA port - LCT(PC) connection

-1-

2. PASOLINK PNMT Cable

Station B

Station A

PASOLINK
NMS Port

PASOLINK

LA Port

182-228615
PNMT
PNMT

Figure 3 LA port - PNMT(PC) connection

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

RS-232C
LCT-TXD
GND
LCT-RXD
LCT-RTS
LCT-CTS
GND
PNMT-CTS
PNMT-RTS
PNMT-RXD
GND
PNMT-TXD

15pin(M)

9 pin(F)

Paso
LA
Connector

PC(PNMT)

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
5
6
7
8
9

1
2
3
4
5
6
7
8
9

CD
RD
TD
DTR
GND
DSR
RTS
CTS
RI

PC(PNMT)

(182-228615)
Figure 4 Pin assignment for LA port PNMT (PC) connection

-2-

Ver.3
3. PASOLINK PNMT + LCT Cable

Station B

Station A

PASOLINK
NMS Port

PASOLINK

LA Port

182-228617
PNMT+LCT

PNMT

or

LCT

Figure 5 LA port - PNMT/LCT(PC) connection

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

RS-232C
LCT-TXD
GND
LCT-RXD
LCT-RTS
LCT-CTS
GND
PNMT-CTS
PNMT-RTS
PNMT-RXD
GND
PNMT-TXD

15pin(M)

9 pin(F)

Paso
LA
Connector

PC(PNMT)

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

9 pin(F)

PC(LCT)

1
2
3
4
5
6
7
8
9

1
2
3
4
5
6
7
8
9

CD
RD
TD
DTR
GND
DSR
RTS
CTS
RI

PC(LCT)

1
2
3
4
5
6
7
8
9

1
2
3
4
5
6
7
8
9

CD
RD
TD
DTR
GND
DSR
RTS
CTS
RI

PC(PNMT)

(182-228617)
Figure 6 Pin assignment for LA port PNMT/LCT (PC) connection

-3-

4. PASOLINK PNMS Cable

Station B

Station A

PASOLINK
NMS Port
[RS232C]

PASOLINK

LA Port

182-228616
PNMS

PNMS (Windows NT only)

Figure 7 NMS port PNMS connection

Station B

Station A

CPM
NMS Port
[RS232C]

RPM
LA Port

182-228616
PNMS
Router

LAN

PNMS
In case of connection to Router, physical interface
shall be adjusted by suitable adaptor(s)

Figure 8 NMS port - Router connection

RS-232C
1 DEBUG-TXD
2
EMS-TXD
3
EMS-RXD
4
5
EMS-RTS
6
EMS-CTS7
GND
8
9 DEBUG-RXD
10
NMS-TXD
11
NMS-RXD
12
13
NMS-RTS
14
NMS-CTS
15

15pin(M)

9 pin(F)

Paso NMS
Connector

PC(PNMS)
1
2
3
4
5
6
7
8
9

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
5
6
7
8
9

CD
RD
TD
DTR
GND
DSR
RTS
CTS
RI

PC (PNMS)
or
Router

(182-228616)
Figure 9 Pin assignment for NMS port PNMS/Router connection

-4-

5. PASOLINK Back to Back Cable (Point to Point)

RPM

CPM

RPM

RPM

NMS Port

NMS Port

182-228618 (RS232C)
182-228619 (RS485)

Figure 10 Back-to-Back (point to point) connection

15pin(M)

RS-232C
DEBUG-TXD
EMS-TXD
EMS-RXD

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

15pin(M)

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

EMS-RTS
EMS-CTSGND
DEBUG-RXD
NMS-TXD
NMS-RXD
NMS-RTS
NMS-CTS

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

RS-232C
DEBUG-TXD
EMS-TXD
EMS-RXD
EMS-RTS
EMS-CTSGND
DEBUG-RXD
NMS-TXD
NMS-RXD
NMS-RTS
NMS-CTS

(182-228618)
Figure 11 Pin assignment for back to back
(point to point, RS232C) connection

15pin(M)

15pin(M)

RS-485
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

RS-485

EMS-TXD+
EMS-TXDEMS-TXDR
EMS-RXD+
EMS-RXDGND
NMS-TXD+
NMS-TXDNMS-TXDR
NMS-RXD+
NMS-RXD-

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

EMS-TXD+
EMS-TXDEMS-TXDR
EMS-RXD+
EMS-RXDGND
NMS-TXD+
NMS-TXDNMS-TXDR
NMS-RXD+
NMS-RXD-

(182-228619)
Figure 12 Pin assignment for back to back
(point to point, RS485) connection

-5-

6. PASOLINK Back to Back Cable (Point to Multi-point)

CPM

SCPM
F

NMS Port
[RS485]

182-228620

RPM

RPM

RPM

SCPM

NMS Port
[RS485]

NMS Port
[RS485]

182-228622

182-228623
F

182-228622

Put on the Termination M at the end of connections

15pin(F)

15pin(M)

Figure 13 Back to Back Cable (point to Multi-point) connection

RS-485
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

EMS-TXD+
EMS-TXDEMS-TXDR
EMS-RXD+
EMS-RXDGND
NMS-TXD+
NMS-TXDNMS-TXDR
NMS-RXD+
NMS-RXD-

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

(182-228620)
Figure 14 Pin assignment for back to back (point to multi-point) connection (1)
Using with Cascade connection cable (182-228622)

0.5 to 15m

15pin(M)

RS-485
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

EMS-TXD+
EMS-TXDEMS-TXDR
EMS-RXD+
EMS-RXDGND

NMS-TXD+
NMS-TXDNMS-TXDR
NMS-RXD+
NMS-RXD-

0.3m

15pin(M)

15pin(F)

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

(182-228622)
Figure 15 Pin assignment for back to back (point to multi-point) connection (2)
(Cascade connection Cable)

15pin(M)

RS-485
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

EMS-TXD+
EMS-TXDEMS-TXDR
EMS-RXD+
EMS-RXDGND

NMS-TXD+
NMS-TXDNMS-TXDR
NMS-RXD+
NMS-RXD-

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

(182-228623)
Figure 16 Pin assignment for back to back (point to multi-point) connection (3)
(Termination connector)

-6-

7. PASO+ LCT Cable

Station B

Station A

PASOLINK+

PASOLINK+

LCT Port

Figure 2
LCT

Figure 1

1
2
3
4
5
6
7
8
9

RS-232C
DCD
RXD
TXD
DTR
GND
DSR
RTS
CTS
RI

LCT port - LCT(PC) connection

9pin(F)

RJ45(Plug)

PC (LCT)

PASOLINK+
LCT port

1
2
3
4
5
6
7
8
9

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

RS-232C
CD
TXD
RXD
DSR
GND
DTR
CTS
RTS

(182-230773)
Figure 2 Pin assignment for LCT port - LCT(PC) connection

-7-

8. PASO+ PNMT Cable

Station B

Station A

PASOLINK+

PASOLINK+

PNMT Port

Figure 4
PNMT

Figure 3

PNMT port - PNMT(PC) connection

9pin(F)
PC (PNMT)

1
2
3
4
5
6
7
8
9

RS-232C
DCD
RXD
TXD
DTR
GND
DSR
RTS
CTS
RI

1
2
3
4
5
6
7
8
9

RJ45(Plug)
PASOLINK+
PNMT port
1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

RS-232C
CD
TXD
RXD
DSR
GND
DTR
CTS
RTS

Same as LTC Cable(Fig 2)


(182-230773)
Figure 4 Pin assignment for PNMT port - PNMT(PC) connection

-8-

9. PASO+ PNMS Cable (LAN interface)

Station B

Station A

PASOLINK+
(CPM)

PASOLINK+

PNMS Port
[LAN ]

Figure 6
Ethernet
HUB

LAN

PNMS

Figure 5 PNMS(LAN) port Ethernet HUB connection

RJ45(Plug
Ethernet HUB

1
2
3
4
5
6
7
8

10BASE-T
RD+
RDTD+
TD-

1
2
3
4
5
6
7
8

RJ45(Plug)
PASOLINK+
PNMS LAN port
1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

10BASE-T
NMS TD+
NMS TDNMS RD+
NMS RD-

(182-230312-05*)
Figure 6 Pin assignment for PNMS(LAN) port Ethernet HUB connection

-9-

10. PASO+ PNMS Cable (Serial(V.11) interafce)

Station B

Station A

PASOLINK+
(CPM)

PASOLINK+

PNMS Port
[V.11 ]

Figure 8

PNMS

: Existing network

Figure 7 PNMS(V.11) port Existing Equipment connection

Existing Equipment

RJ45(Plug)
PASOLINK+
PNMS V.11port
1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

V.11
NMS TD+
NMS TDNMS RD+
NMS RD-

(182-231589-002)
Figure 8 Pin assignment for PNMS(V.11) port Existing Equipment connection

- 10 -

11. PASO+ Back to Back Cable (Point to point)

PNMS

PASOLINK+

PASOLINK+

PASOLINK+

NE1 Port

PASOLINK+

NE1 Port

Figure 10

Station A

Station C

Station B

Figure 9 Back to Back (point to point ) connection


(V.11, 64kbps, Sync)

PNMS side
RJ45(Plug)
PASOLINK+
NE1 port
1
2
3
4
5
6
7
8

V.11
TXD+/ RXD+
TXD-/RXDRXD+/TXD+
Clock+
ClockRXD-/TXDGND
GND

1
2
3
4
5
6
7
8

RJ45(Plug)
PASOLINK+
NE1 port
1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

V.11
RXD+/TXD+
RXD-/TXDTXD+/RXD+
Clock+
ClockTXD-/RXDGND
GND

Same as Figure 6 Cable

(182-230312-03*)
NE1port pin assignment is changed by the location of the NE and PNMS.
In case PNMS is located at the left side of the NE(as indicated this figure),
the pin assignment marked red is applied.
Otherwise if PNMS is located at the right side, another setting is applied.

Figure 10 Pin assignment Back to Back (point to point) connection


(V.11, 64kbps, Sync)

- 11 -

12. PASO+ Back to Back Cable (Point to Multi-point)


PNMS
NE1 Port

NE1 Port

PASOLINK+
(SCPM)

PASOLINK+

PASOLINK+
(SCPM)

PASOLINK+

NE2 Port

Figure 12

NE1 Port
PASOLINK+

PASOLINK+

NE2 Port

Figure 13

NE1 Port
PASOLINK+

PASOLINK+

NE2 Port
NE1 Port
PASOLINK+

PASOLINK+

Figure 11 Pin assignment for Back to Back (point to multi-point ) connection


(RS485, 19.2 kbps, Async)

PNMS side

V.11
TXD+
TXDRXD+
RXDGND
GND

1
2
3
4
5
6
7
8

RJ45(Plug)

RJ45(Plug)

PASOLINK+
NE2 port

PASOLINK+
NE1 port

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

V.11
RXD+
RXDTXD+
TXDGND
GND

Same as Figure 6 Cable

(182-230312-06*)
Figure 12 Pin assignment for Back to Back (point to point) connection
(RS485, 19.2kbps, Async)

PNMS side
RJ45(Plug)

PASOLINK+
NE2 port

V.11
RXD+
RXDTXD+

TXDGND
GND

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

RJ45(Plug)

PASOLINK+
NE1 port

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

V.11
RXD+
RXDTXD+

TXDGND
GND

Same as Figure 6 Cable

(182-230312-06*)
Figure 13 Pin assignment for Back to Back (point to point ) connection
(RS485, 19.2kbps, Async)

- 12 -

13. PASOLINK-PASOLINK+ Cable(1) (Point to Point, PNMS is PASOLINK side)

PNMS

PASOLINK
(SCPM)
NMS Port

PASOLINK

PASOLINK+
(SCPM)
NE2 Port

PASOLINK+

Figure 18

Figure 17 Back to Back (point to point ) connection


between PASOLINK and PASOLINK +, PNMS is PASOLINK side)
(RS485, 9.6 kbps, Async)

PNMS side

15pin(M)
PASOLINK
NMS port

RJ45(Plug)
PASOLINK+
NE2 port

RS-485
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

EMS-TXD+
EMS-TXDEMS-TXDR
EMS-RXD+
EMS-RXDGND
NMS-TXD+
NMS-TXDNMS-TXDR
NMS-RXD+
NMS-RXD-

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

RS-485
XD+
XDRXD+
RXDGND
GND

Cross Connection

(182-231207-0**)
Figure 18 Pin assignment for Back to Back(point to point) connection
between PASOLINK and PASOLINK+, PNMS is PASOLINK side)
(RS485, 9.6 kbps, Async)

- 13 -

14. PASOLINK+-PASOLINK Cable(2) (Point to Point, PNMS is PASOLINK+ side)


PNMS

PASOLINK+
(SCPM)

PASOLINK+

PASOLINK
(CPM)

NE2 Port

PASOLINK

NMS Port

Figure 20

Figure 19 Back to Back (point to point) connection


between PASOLINK+ and PASOLINK, PNMS is PASOLINK+ side)
(V.11, 19.2 kbps, Async)

PNMS side

RJ45(Plug)
PASOLINK+
NE2 port
1
2
3
4
5
6
7
8

RS-485
TXD(+)
TXD(-)
RXD(+)
RXD(-)
GND
GND

15pin(M)
PASOLINK
NMS port
V.11

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

EMS-TXD+
EMS-TXDEMS-TXDR
EMS-RXD+
EMS-RXDGND
NMS-TXD+
NMS-TXDNMS-TXDR
NMS-RXD+
NMS-RXD-

(182-230774)
Figure 20 Pin assignment for Back to Back (point to point) connection
between PASOLINK+ and PASOLINK, PNMS is PASOLINK+ side)
(V.11, 19.2 kbps, Async)

- 14 -

15. PASOLINK+ -PASOLINK Cable (Point to Multi-point, PNMS is PASOLINK+ side) (1)
PNMS

Figure 22

PASOLINK+ PASOLINK
(SCPM)
(CPM)

NE2 Port
F NMS Port

PASOLINK+

PASOLINK

PASOLINK

PASOLINK

NMS Port

Figure 23

PASOLINK

Figure 24

PASOLINK

NMS Port

F
M

TERM-M

Figure 21 Back to Back (Point to multi-point ) connection


between PASOLINK+ and PASOLINK,PNMS is PASOLINK+ side)
(RS485, 9.6 kbps, Async)

PNMS side
RJ45(Plug)

15pin(M)

PASOLINK+
NE2 port
1
2
3
4
5
6
7
8

RS-485
TXD(+)
TXD(-)
RXD(+)

RXD(-)
GND
GND

15pin(F)

PASOLINK
NMS port

PASOLINK
NMS port
RS-485

1
2
3
4
5
6
7
8

Cross Connection

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

EMS-TXD+
EMS-TXDEMS-TXDR
EMS-RXD+
EMS-RXDGND
NMS-TXD+
NMS-TXDNMS-TXDR
NMS-RXD+
NMS-RXD-

Cross Connection

(182-231194)
Figure 22 Pin assignment for Back to Back (Point to multi-point) connection
between PASOLINK+ and PASOLINK,PNMS is PASOLINK + side)
(RS485, 9.6 kbps, Async)

0.5 to 15m

15pin(M)

RS-485
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

EMS-TXD+
EMS-TXDEMS-TXDR
EMS-RXD+
EMS-RXDGND

NMS-TXD+
NMS-TXDNMS-TXDR
NMS-RXD+
NMS-RXD-

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

0.3m

15pin(M)

15pin(F)

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

(182-228622)
Figure 23 Pin assignment for Back to Back (Point to multi-point) connection
between PASOLINK+ and PASOLINK,PNMS is PASOLINK+ side)
(RS485, 9.6 kbps, Async)

15pin(M)

RS-485
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

EMS-TXD+
EMS-TXDEMS-TXDR
EMS-RXD+
EMS-RXDGND
NMS-TXD+
NMS-TXDNMS-TXDR
NMS-RXD+
NMS-RXD-

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

(182-208623)
Figure 24 Pin assignment for Back to Back (Point to multi-point) connection
between PASOLINK+ and PASOLINK,PNMS is PASOLINK+ side)
(RS485, 9.6 kbps, Async)

- 15 -

16. PASOLINK- PASOLINK+ Cable (Point to Multi-point, PNMS is PASOLINK side) (2)
PNMS
Figure 26

NE1Port

PASOLINK

PASOLINK
(SCPM)
NMS Port

Figure 27

PASOLINK+
(SCPM)

PASOLINK+

NE2Port

Cross

NE1Port
PASOLINK+
(SCPM)

PASOLINK+

NE2Port

Figure 28

Straight

NE1Port
PASOLINK+
(SCPM)

PASOLINK+

NE2Port

Cross

Figure 25 Back to Back (Point to multi-point ) connection


between PASOLINK+ and PASOLINK,PNMS is PASOLINK side)
(RS485, 9.6 kbps, Async)

PNMS side

15pin(M)

RJ45(Plug)

PASOLINK
NMS port

PASOLINK+
NE1 port

RS-485
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

EMS-TXD+
EMS-TXDEMS-TXDR
EMS-RXD+
EMS-RXDGND
NMS-TXD+
NMS-TXDNMS-TXDR
NMS-RXD+
NMS-RXD-

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

RS-485
XD+
XDRXD+
RXDGND
GND

Cross Connection

(182-231207-1**)
Figure 26 Pin assignment for Back to Back(point to multi-point) connection
between PASOLINK and PASOLINK+, PNMS is PASOLINK side)
(RS485, 9.6 kbps, Async)

PNMS side

RS-485
TXD+
TXDRXD+
RXDGND
GND

RJ45(Plug)

RJ45(Plug)

PASOLINK+
NE2 port

PASOLINK+
NE1 port

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

RS-485
XD+
XDRXD+

1
2
3
4
5
6
7
8

RXDGND
GND

Straight Connection

(182-230321-06*)
Figure 27 Pin assignment for Back to Back(point to multi-point) connection
between PASOLINK and PASOLINK+, PNMS is PASOLINK side)
(RS485, 9.6 kbps, Async)

PNMS side
RJ45(Plug)

PASOLINK+
NE2 port

RS-485
XD+
XDRXD+
RXDGND
GND

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

RJ45(Plug)

PASOLINK+
NE1 port

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

RS-485
XD+
XDRXD+
RXDGND
GND

Straight Connection

(182-230321-06*)
Figure 28 Pin assignment for Back to Back(point to multi-point) connection
between PASOLINK and PASOLINK+, PNMS is PASOLINK side)
(RS485, 9.6 kbps, Async)

- 16 -

17. PASOLINK+ -PASOLINK Cable (Point to Multi-Point, PNMS is PASOLINK+ side) (3)
PNMS

NE1Port
PASOLINK+

NE1Port
PASOLINK+
(SCPM)

PASOLINK+

PASOLINK+

NE2Port

Cross

Figure 8.30
Cross

PASOLINK
(CPM)

PASOLINK

PASOLINK

PASOLINK

PASOLINK

PASOLINK

Figure 31

Straight

F
M

Figure 32

TERM-M
M

Figure 29 Back to Back (Point to multi-point ) connection


between PASOLINK+ and PASOLINK,PNMS is PASOLINK+ side)
(RS485, 9.6 kbps, Async)

PNMS side
RJ45(Plug)

15pin(M)

PASOLINK+
NE2 port
1
2
3
4
5
6
7
8

RS-485
TXD(+)
TXD(-)
RXD(+)
RXD(-)
GND
GND

15pin(F)

PASOLINK
NMS port

PASOLINK
NMS port
RS-485

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

EMS-TXD+
EMS-TXDEMS-TXDR
EMS-RXD+
EMS-RXDGND
NMS-TXD+
NMS-TXDNMS-TXDR
NMS-RXD+
NMS-RXD-

Cross connection
Same as Figure 22 Cable

(182-231194)
Figure 30 Pin assignment for Back to Back (Point to multi-point) connection
between PASOLINK+ and PASOLINK,PNMS is PASOLINK+ side)
(RS485, 9.6 kbps, Async)

0.5 to 15m

15pin(M)

RS-485
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

EMS-TXD+
EMS-TXDEMS-TXDR
EMS-RXD+
EMS-RXDGND

NMS-TXD+
NMS-TXDNMS-TXDR
NMS-RXD+
NMS-RXD-

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

0.3m

15pin(M)

15pin(F)

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

(182-228622)
Figure 31 Pin assignment for Back to Back (Point to multi-point) connection
between PASOLINK+ and PASOLINK,PNMS is PASOLINK+ side)
(RS485, 9.6 kbps, Async)

15pin(M)

RS-485
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

EMS-TXD+
EMS-TXDEMS-TXDR
EMS-RXD+
EMS-RXDGND
NMS-TXD+
NMS-TXDNMS-TXDR
NMS-RXD+
NMS-RXD-

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

(182-228623)
Figure 32 Pin assignment for Back to Back (Point to multi-point) connection
between PASOLINK+ and PASOLINK,PNMS is PASOLINK+ side)
(RS485, 9.6 kbps, Async)

- 17 -

18. PASOLINK+ -PASOLINK Cable (Point to Multi-Point, PNMS is PASOLINK side) (4)
PNMS

PASOLINK

Cross

PASOLINK

Straight

PASOLINK

PASOLINK

NMS Port
NE1Port

Figure 34
Straight

Figure 35

PASOLINK+
(SCPM)

PASOLINK+

NE2Port
NE1Port
PASOLINK+
(SCPM)

PASOLINK+

NE2Port
Straight

NE1Port
PASOLINK+
(SCPM)

PASOLINK+

NE2Port

Figure 33 Back to Back (Point to multi-point ) connection


between PASOLINK+ and PASOLINK,PNMS is PASOLINK side)
(RS485, 9.6 kbps, Async)

PNMS side

15pin(M)

15pin(M)

PASOLINK
NMS port

PASOLINK
NMS port

RJ45(Plug)
PASOLINK+
NE1 port

RS-485
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

EMS-TXD+
EMS-TXDEMS-TXDR
EMS-RXD+
EMS-RXDGND
NMS-TXD+
NMS-TXDNMS-TXDR
NMS-RXD+
NMS-RXD-

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

RS-485
XD+
XDRXD+
RXDGND
GND

Straight
Cross

(182-231195)
Figure 34 Pin assignment for Back to Back (Point to multi-point) connection
between PASOLINK+ and PASOLINK,PNMS is PASOLINK side)
(RS485, 9.6 kbps, Async)

PNMS side
RJ45(Plug)
PASOLINK+
NE2 port

RS-485
XD+
XDRXD+

RXDGND
GND

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

RJ45(Plug)
PASOLINK+
NE1 port

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

RS-485
XD+
XDRXD+

RXDGND
GND

Straight

(182-230312-06*)
Figure 35 Pin assignment for Back to Back (Point to multi-point) connection
between PASOLINK+ and PASOLINK,PNMS is PASOLINK side)
(RS485, 9.6 kbps, Async)

- 18 -

19. PASOLINK+ -PASOLINK Cable (Point to Multi-Point, PNMS is PASOLINK side) (5)
PNMS
Figure 37

Cross
F M

PASOLINK

PASOLINK

PASOLINK

NMS Port

Figure 38

PASOLINK

NMS Port

Straight

Straight

PASOLINK

PASOLINK

NMS Port

Straight

Figure 39

NE1Port
PASOLINK+
(SCPM)

PASOLINK+
(SCPM)
NE2Port
Straight

NE1Port
PASOLINK+
(SCPM)

PASOLINK+
(SCPM)
Straight

15pin(F)

15pin(M)

Figure 36 Back to Back (Point to multi-point ) connection


between PASOLINK+ and PASOLINK,PNMS is PASOLINK side)
(RS485, 9.6 kbps, Async)

RS-485
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

EMS-TXD+
EMS-TXDEMS-TXDR
EMS-RXD+
EMS-RXDGND
NMS-TXD+
NMS-TXDNMS-TXDR
NMS-RXD+
NMS-RXD-

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

(182-228620)
Figure 37 Pin assignment for Back to Back (Point to multi-point) connection
between PASOLINK + and PASOLINK,PNMS is PASOLINK side)
(RS485, 9.6 kbps, Async)

0.5 to 15m

15pin(M)

RS-485
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

EMS-TXD+
EMS-TXDEMS-TXDR
EMS-RXD+
EMS-RXDGND

NMS-TXD+
NMS-TXDNMS-TXDR
NMS-RXD+
NMS-RXD-

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

0.3m

15pin(M)

15pin(F)

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

(182-228622)
Figure 38 Pin assignment for Back to Back (Point to multi-point) connection
between PASOLINK+ and PASOLINK,PNMS is PASOLINK side)
(RS485, 9.6 kbps, Async)

PNMS side

15pin(M)
PASOLINK
NMS port

15pin(M)
PASOLINK
NMS port

RJ45(Plug)
PASOLINK+
NE1 port

RS-485
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

EMS-TXD+
EMS-TXDEMS-TXDR
EMS-RXD+
EMS-RXDGND

NMS-TXD+
NMS-TXDNMS-TXDR
NMS-RXD+
NMS-RXD-

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

RS-485
XD+
XDRXD+

RXDGND
GND

Straight

Straight

(182-231196-0**)
Figure 39 Pin assignment for Back to Back (Point to multi-point) connection
between PASOLINK+ and PASOLINK,PNMS is PASOLINK side)
(RS485, 9.6 kbps, Async)

- 19 -