Sie sind auf Seite 1von 3

Existing Gas Removal System Process Flow Diagram

Mass Balance Existing Gas Removal System (GRS)


Stream Number
Source
Destination
Temperature (oC)
Pressure (bara)
Vapor Fraction
Total Mass Flowrate (ton/hr)
Total Mole Flowrate (kmol/hr)
Individual Mass Flowrate (ton/hr)
H2O
CO2
H2S
Air (N2+O2)

1
Separator
Splitter
172,0
8,32
1,00
145,9920
8.033,3158

2
Splitter
T-01
172,0
8,32
1,00
139,6983
7.687,0107

3
Splitter
Splitter
169,1
7,78
1,00
6,2937
346,3051

4
T-01
E-01
54,7
0,16
1,00
139,6983
7.687,0107

5
CT-01
E-01
30,5
1,29
0,00
3.726,5191
207.028,8389

6
E-01
Splitter
54,7
0,16
1,00
2,7051
76,2774

7
E-03
E-01
56,7
1,19
0,00
73,9260
4.107,0000

8
E-02
E-01
54,1
0,51
0,00
107,2100
5.956,1111

9
E-01
Splitter
52,4
0,16
0,00
4.044,7020
224.705,6667

10
Splitter
JE-01
169,1
7,78
1,00
3,6845
202,7356

143,6122
2,2628
0,1167
-

137,4212
2,1653
0,1118
-

6,1910
0,0975
0,0049
-

137,4212
2,1653
0,1118
-

3.726,5191
-

0,4280
2,1653
0,1118
-

73,9260
-

107,2100
-

4.044,7020
-

3,6244
0,0571
0,0028
-

11
JE-01
E-02
117,9
0,51
1,00
6,3896
279,0160

12
P-03
E-02
30,5
1,29
0,00
103,4216
5.745,6444

13
E-02
Splitter
54,1
0,51
1,00
2,5970
68,3215

14
Splitter
JE-03
54,1
0,51
1,00
1,2984
34,1594

15
Splitter
JE-03
168,0
7,58
1,00
1,3046
71,7847

16
JE-03
Mixer
140,7
1,19
1,00
2,6030
105,9442

17
Splitter
JE-04
54,1
0,51
1,00
1,2984
34,1594

18
Splitter
JE-04
168,0
7,58
1,00
1,3046
71,7847

19
JE-04
Mixer
140,7
1,19
1,00
2,6030
105,9442

20
Mixer
E-03
140,7
1,19
1,00
5,2060
211,8883

4,0524
2,2224
0,1147
-

103,4216
-

0,2599
2,2224
0,1147
-

0,1299
1,1112
0,0574
-

1,2833
0,0202
0,0010
-

1,4132
1,1314
0,0584
-

0,1299
1,1112
0,0574
-

1,2833
0,0202
0,0010
-

1,4132
1,1314
0,0584
-

2,8264
2,2628
0,1169
-

28
CT-01
Atmosphere
65,0
1
1
200,6794
20.259,701

(Continued)
Stream Number
Source
Destination
Temperature (oC)
Pressure (bara)
Vapor Fraction
Total Mass Flowrate (ton/hr)
Total Mole Flowrate (kmol/hr)
Individual Mass Flowrate (ton/hr)
H2O
CO2
H2S
Air (N2+O2)

(Continued)
Stream Number
Source
Destination
Temperature (oC)
Pressure (bara)
Vapor Fraction
Total Mass Flowrate (ton/hr)
Total Mole Flowrate (kmol/hr)

21
Splitter
E-03
30,5
1,19
71,1600

22
E-02
CT-01
67,3
1,19
1,00
2,4386

23
Splitter
P-01
52,4
0,16
2.022,3510

24
Splitter
P-02
52,4
0,16
2.022,3510

25
Mixer
CT-01
52,4
1,50
4.044,7020

26
CT-01
Splitter
30,5
1,29
3.901,1007

27
Atmosphere
CT-01
25,0
1
1
54,6395

3.953,3333

58,1322

112.352,8333

112.352,8333

224.705,6667

216.727,8167

12.223,7197

Individual Mass Flowrate (ton/hr)


H2O
CO2
H2S
Air (N2+O2)

71,1600
-

0,0588
2,2628
0,1169
-

2.022,3510
-

2.022,3510
-

4.044,7020
-

3.901,1007
-

54,6395

143,6601
2,2628
0,1169
54,6395

Equipment Total Mass Balance Checking


Equipment Name (Code)
Turbine (T-01)
Main Condenser (E-01)
Steam Jet Gas Ejector 1st Stage A (JE-01)
Steam Jet Gas Ejector 1st Stage B (JE-02)
Inter Condenser (E-02)
Steam Jet Gas Ejector 2nd Stage A (JE-03)
Steam Jet Gas Ejector 2nd Stage B (JE-04)
After Condenser (E-03)
Hot Well Pump A (P-01)
Hot Well Pump B (P-02)
Cooling Tower (CT-01)
Primary Auxiliary Cooling Water Pump (P-03)

IN

OUT
139,70
4.047,35
6,39
109,81
2,60
2,60
76,37
2.022,35
2.022,35
4.101,78
174,58

139,70
4.047,41
6,39
109,81
2,60
2,60
76,36
2.022,35
2.022,35
4.101,78
174,58

Mass Difference
-

Status
balance
balance
balance
inactive
balance
balance
balance
balance
balance
balance
balance
balance