Model

Range
Best
Accuracy

9142/9142
9143/9143P 9144/9144P
P

4180

4181

25 C to
33 C to 350 50 C to 660
150 C 415 C to 120 C 35 C to 500 C
C 4-20 mA C 4-20 mA
20 mA
0.2 C

0.2 C

0.35 C

0.35 C

0.35 C

9100S

35 C to 375 C 10 C to 122 C

0.25 C

Applications

Temperature transmitter, switch, and controller loop calibration


Infrared thermometer and thermal imager calibration
RTD Calibration
Website: us.flukecal.com

Call:

9102S

0.25 C

Fluke Calibration 9142, 9143, 9144 Field Metrology Wells

Features :
Lightweight, portable, and fast
Built-in two-channel readout for PRT,
RTD, thermocouple, 4-20 mA current

True reference thermometry with


accuracy to
0.01 C
Specifications guaranteed in an
ambient range of 13 C to 33 C
On-board automation and
documentation
Website: us.flukecal.com

Call:

Typical Applications

Thermocouple calibration or verification


Calibrations of RTDs or PRTs
Testing of thermostatic switches
Verification of industrial thermometers
Loop calibration of temperature transmitters

Website: us.flukecal.com

Call:

Summary Specifications
for
9142, 9143, and 9144

Website: us.flukecal.com

Call:

Fluke Calibration 4180 and 4181 Precision Infrared Calibrators

Features :
Combined temperature range of -15 C
to 500 C
Infrared display accuracy as good as
0.35 C on both units
Convenient handle and weight of 9.5 kg
(21 lbs) or less for portability
Stability as good as 0.05 C over 30
minutes for both models
Uniformity as good as 0.1 C over the
inner 127 mm (5 in) diameter
Website: us.flukecal.com

Call:

Typical Applications

o Infrared thermometer calibration


o Thermal imager testing

Website: us.flukecal.com

Call:

Summary Specifications for


4180 and 4181

Website: us.flukecal.com

Call:

Fluke Calibration 9100S and


9102S Handheld Dry-Well
Temperature Calibrators
Features :
Smallest dry wells in the world
Fast and easy calibrations of temperature
sensors
9100S model weighs only 2 lbs, 3 oz (1
kilogram)
Measure Temperature ranges from -10 C
to 375 C
Stability during calibrations to 0.05 C
Website:
Direct interface
to the
Fluke 754
us.flukecal.com
Call:

Typical Applications

RTD calibration
Thermocouple calibration
Small bimetal thermometer calibration

Website: us.flukecal.com

Call:

Summary Specifications
for
9100S and 9102S