Q.1) Wet venting is applied whenever
A. there are 1 or 2 fixtures at every level (Your Answer)
B. fixtures are of the same level (Correct Answer)
C. fixtures are not vented individually
D. none of these
Correct
Q.2) What is the minimum pipe size of the standpipe if the highest outlet is
located more than 23 meters above the Fire Service connection?
A. 3 inches
B. 6 inches (Your Answer)
C. 5 inches
D. 4 inches
Correct
Q.3) What is the minimum dimension for a turning space in a water closet stall
intended for disabled persons?
A. 2.00 m
B. 1.20 m
C. 1.00 m
D. 1.50 m (Your Answer)
Correct
Q.4) What type of PVC female screws for water piping is prohibited under the
code?
A. Tapped
B. Job fabricated (Your Answer)
C. Seamless
D. Schedule 20 screws
Correct
Q.5) To what provision does the design, construction and operation of deep wells
for the abstraction of ground water will have to follow?
A. National Plumbing Code of the Philippines
B. National Standards for Drinking Water
C. Water Code of the Philippines (Your Answer)
D. Code of Sanitation
Correct
Q.6) Where practical, all pipes from fixtures shall be run in what direction with
respect to the nearest wall or building line?

A. offset
B. parallel (Your Answer)
C. across
D. perpendicular
Incorrect
Q.7) The following are grounds for non-issuance of the certificate of registration
by the Board of Master Plumbers EXCEPT
A. convicted by court for any criminal offense
B. of unsound mind (Your Answer)
C. guilty of immoral or dishonorable conduct
D. failure to pay the required fees (Correct Answer)
Correct
Q.8) What government agency is tasked to set the criteria in the discharge of
sanitary sewage from buildings or pretreated industrial wastewater directly
into the nearest sanitary sewer main?
A. National Pollution Control Commission
B. Dept of Environment and Natural Resources (Your Answer)
C. Department of Health
D. Department of Public Works
Correct
Q.9) What is the nimimum floor area in every storey which is used for habitation,
recreation, dining, study of work and which has an occupiped load of not
more than 20, wherein a standard automatic extinguishing system is a
A. 300 sq.m
B. 200 sq.m (Your Answer)
C. 400 sq.m
D. 500 sq.m
Correct
Q.10) In accordance to the Building Code, what must be provided in addition to
septic tanks by building located in areas where there is no sanitary sewerage
system whenever they will dispose their waste?
A. Baffle plate
B. Subsurface absorption filed (Your Answer)
C. Imhoff tank
D. Settling chamber
Correct
Q.11) For new, additional or altered plumbing installation not exceeding 20 units,
the Building Code stated that a Licensed Master Plumber could sign and
affix his seal on the follwing engineering documents except
A. Plumbing plan and layout

B. Design analysis and plans of the original installation (Your Answer)


C. Isometric drawing
D. Guide specifications and bill of materials
Correct
Q.12) What kind of septic tank is prohibited?
A. CONCRETE
B. STEEL
C. PLASTIC
D. WOODEN (Your Answer)
Correct
Q.13) Who shall set the criteria for the quality of drinking water from meteoric,
surface or underground sources?
A. National Water Resources Board
B. Department of Health
C. National Standards for Drinking Water (Your Answer)
D. Department of Environment and Natural Resources
Correct
Q.14) The cover of gravity tanks shall be vented using a screened
A. return bend pipe (Your Answer)
B. upright pipe
C. horizontal nipple
D. all of these
Correct
Q.15) What institution standart used as a reference for joining pipes?
A. ASSE
B. ASPE
C. ANSI
D. IAPMO (Your Answer)
Correct
Q.16) Whenever the piping is pressurized by a pump or ejector, what kind of pipe
should not be used in the excreta drainage system?
A. vitrified clay pipe (Your Answer)
B. hubless cast iron
C. galvanized wrought iron
D. none of these
Correct
Q.17) What is the minimum horizontal clear dsitance from the septic tank to the
property line of the adjoining private property?

A. 1.0 m
B. 1.2 m
C. 1.5 m (Your Answer)
D. 1.8 m
Incorrect
Q.18) Drainage piping serving fixtures located below the crown level of the main
sewer shall discharge into an approved water tight
A. septic tank (Your Answer)
B. sump (Correct Answer)
C. cesspool
D. leaching tank
Incorrect
Q.19) What is the maximum water pressure must standpipe fittings and
connections must withstand to when ready for service?
A. 21 kg/cm (Correct Answer)
B. 34 kg/cm
C. 15 kg/cm
D. 8 kg/cm (Your Answer)
Incorrect
Q.20) To allow cleaning of the soil and waste line each cleanout should be
installed
A. in the direction of flow (Correct Answer)
B. opening upward (Your Answer)
C. vertically above flow line
D. all of these
Correct
Q.21) If the discharge of a fixture or drain may contain solids or semisolids
heavier than water that would be harmful to the drainage system or cause
stopaage within the system, where the discharge must pass first?
A. Sand interceptor (Your Answer)
B. Screen wire mesh
C. Wooden baffle
Correct
Q.22) What portion of the trap should the vent pipe opening will not go below
from a soil or waste pipe?
A. slip joint
B. weir (Your Answer)
C. sleeve
D. seal
Correct

Q.23) A kind of cleanout plugs that will be installed in case where raised heads
may cause hazards to passing personnel or vehicles.
A. depressed
B. countersunk (Your Answer)
C. embedded
D. recessed
Incorrect
Q.24) How does a pneumatic tank be designed to supply adequate water pressure
in all floors of a building that will be in accordance with the Building Code?
A. Twice the maximum total dynamic pressure required (Correct Answer)
B. Equal to the total water supply fixture units (Your Answer)
C. Twice the total demand per capita
D. Equal to the total dynamic head and minus all the head losses
Correct
Q.25) The minimum requirement for the slope of horizontal drainage pipes
between manholes is
A. 2% (Your Answer)
B. 2 1/2%
C. 3%
D. 4%
Correct
Q.26) What is the minimum total net inlet area of roof deck drains on roof deck
used as sun decks and parking decks?
A. equal to the area of outlet pipe
B. equal to 4 times the area of outlet pipe
C. equal to 2 times the area of outlet pipe (Your Answer)
D. equal to 1 1/2 times the area of outlet pipe
Incorrect
Q.27) What is the minimum number of water closet in a floor level wherein you
have to provide 1 water closet for disabled persons as provided by Batas
Pambansa Blg. 344? in excess of this number you have to provide 2.
A. 12
B. 15
C. 20 (Correct Answer)
D. 10 (Your Answer)
Correct
Q.28) How many units do the controversial Article 3.2.2.2 of PD 1096 otherwise
known as the National Building Code limits the practice of Master Plumber?

A. 20 (Your Answer)
B. 10
C. 5
D. 50
Correct
Q.29) What kind of concealed connections on fixtures that it is required to provide
an access panel or utility at least 0.30 meter in its least dimension for easy
inspection and repair?
A. slip joint (Your Answer)
B. ball and socket
C. hubless
D. flanged
Correct
Q.30) Who is authorized to issue rules and regulations to carry into effect the
objectives of Rep. Act 1378?
A. Board of Master Plumbers
B. Congress of the Philippines
C. President of the Philippines (Your Answer)
D. Professional Regulation Commision
Correct
Q.31) Within how many meters away shall unions be installed from regulating
equipment, water heater, conditioning tank and similar equipment which
require removal for servicing or replacement?
A. 2 ft
B. 1 m
C. 5 ft
D. 0.3 m (Your Answer)
Correct
Q.32) Which of the following is not considered as suds-producing fixture?
A. kitchen sink
B. bath tub
C. washing machine
D. bidet (Your Answer)
Correct
Q.33) What is the type of Siamese connection that all 125-millimeter dry
standpipes shall be equipped with?
A. three-way (Your Answer)
B. two-way
C. four-way
D. one-way

Incorrect
Q.34) The following are the data required whenever a Registered Master Plumber
sign the blueprint of the building plan EXCEPT
A. Date of PRC registration
B. PTR date (Your Answer)
C. Registration expiry date (Correct Answer)
D. none of these
Correct
Q.35) Unless serving sinks or urinals, cleanouts may be omitted on a horizontal
drain line that is
A. equal to 2.0 meters
B. greater than 2.0 meters
C. less than 1.5 meters (Your Answer)
D. none of these
Correct
Q.36) In the excreta drainage system, which of the following pipe materials should
not be used underground?
A. vitrified clay pipe
B. hubless cast iron
C. galvanized wrought iron (Your Answer)
D. none of the above
Incorrect
Q.37) Who among the Board Examiners is not a signatory to PRC Resolution 04
that request for the adoption and promulgation of the Revised National
Plumbing Code of the Philippines in 1999?
A. Imelda Perez (Correct Answer)
B. Aida Emely Luz (Your Answer)
C. Fortunato Amosco
D. Jesus Pacheco
Correct
Q.38) What shape of signage is shown for mens showroom?
A. SQUARE
B. CIRCLE
C. TRIANGLE (Your Answer)
D. RECTANGLE
Correct
Q.39) Who is the current chairman of the Board of Examiners for Master
Plumber?

A. Fortunato Amosco
B. Virgilio Simbulan (Your Answer)
C. Jessie Mariano
D. Valerin Maogila
Correct
Q.40) Which of the following plumbing code in USA does the National Plumbing
Code of the Philippines was being patterned for?
A. Standard Plumbing Code
B. ASPE Code
C. Uniform Plumbing Code (Your Answer)
D. International Plumbing Code
Correct
Q.41) Except on what fixture does the vent pipe opening from the soil or waste
pipe must not be below the weir of the trap?
A. lavatory
B. kitchen sink
C. bath tub
D. water closet (Your Answer)
Correct
Q.42) Accordingto Batas Pambansa Blg. 344, what type of urinal should be
provided for disabled persons?
A. WALL-HUNG TYPE
B. PEDESTAL TYPE
C. TROUGH TYPE (Your Answer)
D. NONE OF THESE
Correct
Q.43) What should be done whenever a partition contains some piping and runs
parallel to the floor joist underneath?
A. Notching should be introduced into the joist
B. Adjust the joist to make it perpendicular with the direction of pipe
C. Space the joist wider to accommodate the pipe
D. Double the joist (Your Answer)
Correct
Q.44) What is the maximum allowable lead content of pipe and fitting for potable
piping system?
A. 0%
B. 2%
C. 5%
D. 8% (Your Answer)
Correct

Q.45) What shall be issued by the Administrative Authority for the construction of
a part of a large and/or complicated plumbing system before the entire plans
and specifications for the whole system have been submitted or approved?
A. restraining order
B. partial permit (Your Answer)
C. summon
D. evaluation sheet
Incorrect
Q.46) According to the Code, the desgign of roof gutters is based on the maximum
roof area. What is the shape of the gutter does the desgn table for storm
sewer is being based to?
A. Circular (Your Answer)
B. Restangular
C. Ovate
D. Semi-circular (Correct Answer)
Correct
Q.47) Unless prohibited by structural conditions, what is the reference of each
vertical vent pipes before offsetting horizontally to join the stack vent or
vent stack?
A. invert of trap
B. air gap of fixture
C. water level inside the trap
D. highest flood level rim of fixture (Your Answer)
Correct
Q.48) A stack, as defined in the code, is ___
A. the main vent
B. any vertical vent
C. the horizontal main of soil, waste, or vent stack
the vertical main of soil, waste, or vent piping that extends one or more
D.
stories (Your Answer)
Correct
Q.49) If a septic tank has a compartment that exceed 3.7 m in length, what should
be the additional requirement?
A. An additional manhole (Your Answer)
B. Increase the size of the leaching chamber
C. Increase the number of compartments
D. Baffle wall is added
Correct
Q.50) The Building Code stated that all dry standpipe outlets shall be equipped

with valves having substantial chains. What kind of valve is this?


A. Check valve
B. Globe valve
C. Gate valve (Your Answer)
D. Ball valve
Correct
Q.51) Who was awarded as the most outstanding Registered Master Plumber for
the Year 2011?
A. Dave Vela (Your Answer)
B. Alberto Azarcon
C. Alberto Cabael
D. Thelma Cardente
Correct
Q.52) What is the fee if an expired plumbing permit is renewed?
A. P 150.00
B. Equal to the original fee
C. Double of the original fee
D. 1/2 of the original fee (Your Answer)
Correct
Q.53) Aside from Bell and Spigot, B & S in the code means
A. Ball and Socket
B. Browning and Smith
C. Butt and Soldered
D. Brown and Sharp (Your Answer)
Correct
Q.54) What is the maximum distance as where supports of vertical cast iron soil
pipes are made?
A. every 3.0 m
B. every meter
C. every storey (Your Answer)
D. every joint
Correct
Q.55) In order as not to impede the movement of a person in wheel chair and to
have a convenient access on the lavatory, what is the allowable knee recess
vertical clearance that will be provided?
A. 0.50 m to 0.80 m
B. 0.60 m to 0.80 m
C. 0.40 m to 0.70 m
D. 0.60 m to 0.70 m (Your Answer)

Correct
Q.56) Under the Accessibilty Law, what is the minimum area of water closet
stalls?
A. 1.7 x 1.8 meters (Your Answer)
B. 2.0 x 2.0 meters
C. 1.5 x 1.8 meters
D. 1.2 x 2.0 meters
Incorrect
Q.57) According to Art 3.2.2.2 of PD 1096 what scope of work in plan preparation
for new sanitary installations with more than 20 units does a sanitary
engineer differs with a Registered Master Plumber?
Det. all drawings of septic tanks in the absence of disposal field (Correct
Answer)
B. Sanitary plan, layout and details (Your Answer)
C. Cost estimate
D. Isometric drawings of roughing in.
Correct
A.

Q.58) Which of the following is the primary basics for sizing vertical rainwater
piping in the Revised National Plumbing Code?
A. intensity of rainfall (Your Answer)
B. wind direction
C. slope of roof
D. roof area
Correct
Q.59) Which of the following is not included in a plumbing unit?
A. Water Meter
B. Floor Drain
C. Urinal (Your Answer)
D. Laundry Tray
Correct
Q.60) In sizing the grease interceptors, four elements are being used. Two of these
elements are number of meals per peak hour and the waste flow rate. Whta
are the other two elemets?
A. Slope and retention time
B. Storage factor and time of concentration
C. Retention time and storage factor (Your Answer)
D. Percolation rate and time of concentration
Correct
Q.61) What is the maximum height should a water closet have if it is intended for

a disabled person.
A. 0.40m
B. 0.50m *
C. 0.45m (Your Answer)
D. 0.35m
Correct
Q.62) What kind of joint is not allowed in cast iron pipe?
A. Welded
B. Threaded (Your Answer)
C. Soldered
D. Ball and Spigot
Incorrect
Q.63) A fitting for lead-caulked joint that is prohibited when in vertical position
A. single hub
B. double hub (Correct Answer)
C. double tapped tee
D. all of these (Your Answer)
Incorrect
Q.64) Who was the first Charter President of NAMPAP?
A. Antonio Mansueto Sr.
B. Comelio G. Odvina
C. Jesus Tanghal Dera (Your Answer)
D. Catalino C. Casupanan (Correct Answer)
Correct
Q.65) Aside from the number of fixture units connected to it, the size of the vent
piping is determined by its
A. number of inlets
B. length (Your Answer)
C. discharge
D. loading
Correct
Q.66) Where should the overflow pipe lead for overhead tank installed on
buildings?
A. Soil stack
B. Scuppers
C. Storm drain (Your Answer)
D. Gutter
Correct

Q.67) A plumbing permit shall expire and become null and void if the plumbing
work authorized therein if not started for how many days?
A. 30 days
B. 45 days
C. 100 days
D. 365 days (Your Answer)
Correct
Q.68) Except for plastic piping system, hot and cold water piping may be tested
wtih ___
50 psi of the working pressure of the water in the system for at least 15
minutes (Your Answer)
B. 100 psi air for at least 10 minutes
C. 35 psi air for at least 15 minutes
D. 40 psi air or 150 psi water for 10 minutes
Correct
A.

Q.69) Building sewers shall be tested by completely filling the sewer with water
from the ___
A. lowest to the highest point (Your Answer)
B. lowest to at least ground level
C. lowest to at least a 10-foot head
D. lowest to at least a 5-foot head
Correct
Q.70) Aside from galvanized steel, what is the other material for dry standpipe that
the Building Code allows?
A. PVC pipe
B. Wrought iron (Your Answer)
C. PE pipe
D. Brass
Correct
Q.71) The appropriate sealant that will be used to cover void spaces between pipes
and sleeves through concrete floors in the ground
A. bitumen (Your Answer)
B. epoxy
C. grease
D. putty
Correct
Q.72) Who has the power to remove any member of the Board of Master Plumbers
for neglect of duty, incompetence, malpratice and unprofessional or
dishonorable conduct?

A. President of the Philippines (Your Answer)


B. Civil Service Commisioner
C. Chairman of PRC Commisioners
D. Commision on Appointments
Correct
Q.73) According to the Building Code of the Philippines what is the range in
height above grade should the Siamese fire department conncetion be
installed?
A. 30 cm to 1.2 m (Your Answer)
B. 60 cm to 1.5 m
C. 80 cm to 1.8 m
D. 50 cm to 1.0 m
Correct
Q.74) If ever pipes are to pass through masonry by using pipe sleeves, how far
must each pipe be from each other?
A. Minimum of three diameters, center to center (Your Answer)
B. Minimum of three diameters flushed from each hole
C. Minimum of 0.15 m on centers
D. Maximum of two diameters flushed from each hole
Correct
Q.75) PD No. 1185 is another law that Master Plumbers used as their guide in the
practice of the plumbing profession.What is PD No. 1185?
A. Accessibilty Law
B. Fire Code of the Philippines (Your Answer)
C. Water Code of the Philippines
D. Code of Sanitation
Correct
Q.76) What is the minimum allowable interval for the support of plastic pipes
when installed vertically
A. 2ft
B. 5ft
C. 1 meter (Your Answer)
D. 1.5 meter
Correct
Q.77) Which of the following could be omitted if the trap arm changes direction
that does not exceed 90 degrees?
A. Wye
B. Cleanout (Your Answer)
C. Long sweep
D. Combination of 1/8 bend and wye

Correct
Q.78) For a vertical drainage line that is installed to be truly in vertical position,
what is the allowed degeree of the branch to be used?
A. 10
B. 45
C. 30
D. 60 (Your Answer)
Correct
Q.79) What is the masimum length of the fire hose that shall be equipped on wet
standpipes?
A. 12 meters
B. 23 meters (Your Answer)
C. 17 meters
D. 25 meters
Incorrect
Q.80) When can a vertical piping be considered to be wet vented?
A. between openings of vent pipes
B. between any two consecutive inlet levels (Correct Answer)
C. on stack vent
D. when serving two water closets at different levels (Your Answer)
Incorrect
Q.81) With what standard specification must all pipe materials must conform to?
A. Product Strandard of the Philippines (Correct Answer)
B. Interational Producers Standard
C. Philippine Standard Council (Your Answer)
D. Department of Trade and Industry
Incorrect
Q.82) A type of drainage and venting system with universal branch line that is
prohibited
A. single (Correct Answer)
B. dual (Your Answer)
C. dependent
D. alternate
Correct
Q.83) Article 3.2.2.2 of PD 1096 actually allows a Registered Master Plumber to
sign and seal plans for new sanitary installations of more than twenty (20)
plumbing units. Aside from being a Registered Master Plumber what is the
other requirement that you must have before you can sign and seal it?

A. A registered engineer (Your Answer)


B. An engineering graduate
C. Having a minimum experience of 5 years
D. A member of NAMPAP
Correct
Q.84) What is the minimum number of approved slip joints fittings may be used
on the putlet side of the trap?
A. three
B. two
C. none
D. one (Your Answer)
Incorrect
Q.85) Who is empowered to administer the provision of Rep. Act 1378?
A. Office of the President
B. Congress of the Philippines
C. The Board of Examiners for Master Plumbers (Correct Answer)
D. Professional Regulation Commision (Your Answer)
Incorrect
Q.86) Under what law did plumbing became a duly recognized profession by the
Philppine government?
A. Nat'l Plumbing Code of the Phil of 1959
B. Tydings McDuffie Act of 1905
C. Jones Law of 1907 (Correct Answer)
D. Republic Act 1378 (Your Answer)
Correct
Q.87) What is the shape for the signage for women's comfort room in order to aid
visually impaired women readilty determine whether a washroom is for men
or women?
A. CIRCLE (Your Answer)
B. RECTANGLE
C. TRIANGLE
D. SQUARE
Correct
Q.88) What installation standard is followed in joining plastic pipe and fittings by
solvent cement?
A. ISO
B. ANSI
C. IAPMO (Your Answer)
D. ASHRAE
Correct

Q.89) When shall the installation of plumbing equipment to supply building or


structures from existing water supply system only be allowed to?
A. If the water demand is inadequate
B. Whenever the water supply is scantity availbale
C. When there is always water in the main (Your Answer)
D. When water is not available in the vicinity
Incorrect
Q.90) For how many days shall the REvised National Plumbing Code will take
effect following its complete publication in the Official Gazette?
A. 100 days (Correct Answer)
B. 60 days
C. 50 days
D. 30 days (Your Answer)
Correct
Q.91) For the hot and cold water distribution system, on what side should the hot
water supply be placed in combination fittings?
A. left (Your Answer)
B. right
C. center
D. none of these
Correct
Q.92) What is the minimum pipe size of the standpipe if the highest outlet is
located 23 meters or less above the Fire Service connection?
A. 3 inches
B. 6 inches
C. 5 inches
D. 4 inches (Your Answer)
Correct
Q.93) Within how many days upon the approval of Rep. Act No. 1378 does it
require to have a Board Examiners for Master Plumbers formed?
A. Thirty days (Your Answer)
B. Fortyfive days
C. Sixty days
D. Fifteen days
Correct
Q.94) What is the minimum number of years of experience must a Registered
Master Plumber be before he can be a technical staff of a Building Office?
A. one year

B. three years (Your Answer)


C. two years
D. five years
Correct
Q.95) Where the number of water closets in a floor level exceeds 20, how many of
these shall be provided to the disabled persons?
A. 1
B. 2 (Your Answer)
C. 3
D. 4
Incorrect
Q.96) What is the PRC Resolution Number is issued by the Board of Master
Plumbing for the adoption and promulgation of the Revised National
Plumbing Code of the Philippines?
A. Res. No. 2
B. Res. No. 1378 (Your Answer)
C. Res. No. 4 (Correct Answer)
D. Res. No. 962
Correct
Q.97) What is the name of the professional orginazation for the Registered Master
Plumbers here in the Philippines?
A. National Association of Master Plumbing of the Philippines
B. National Association of Master Plumbers of the Phillipines
C. National Master Plumbers Association of the Philippines (Your Answer)
D. National Master Plumbing Association of the Philippines
Correct
Q.98) NAMPAP is a professional organization of Registered Master Plumber
under PRC. What is the PRC accreditation number of NAMPAP?
A. 10
B. 14 (Your Answer)
C. 18
D. 12
Incorrect
Q.99) Of the four board subjects given for Master Plumbers examination, which of
this subject was originally split into two subject?
A. Practical Problems (Correct Answer)
B. Design And Installations (Your Answer)
C. Plumbing Code
D. Plumbing Arithmetic
Correct

Q.100) In 1966- 1969, the Board of Master Plumbers and NAMPAP prepared a
curriculum for Plumbing Engineering and approved by the Department of
Education. What was the first school that introduced the Plumbing
Engineering curriculum?
A. Feati University (Your Answer)
B. University of the Philippines
C. Mapua Institute of Technology
D. National University
Correct
Q.101) In the water test of the entire plumbing system all openings should be
tightly closed except at
A. producing cleanouts
B. highest opening (Your Answer)
C. stack vent
D. bleeders
Correct
Q.102) Which of the following is a prohibited fixture inside a public toilet room?
A. faucet
B. drinking fountain (Your Answer)
C. slop sink
D. bidet
Correct
Q.103) In what year did NAMPAP was incorporated as a professional
organization?
A. 1935 (Your Answer)
B. 1956
C. 1946
D. 1968
Correct
Q.104) What is not needed to be installed when a combination standpipe system is
installed in accordance with the Fire Code?
A. dry standpipe (Your Answer)
B. wet standpipe
C. sprinkler system
D. siamese connection
Incorrect
Q.105) What is the minimum diameter of vent pipe is allowed in the revised
Code?

A. 1 inch
B. 1 1/4 inch (Correct Answer)
C. 2 inch
D. 1 1/2 inch (Your Answer)
Incorrect
Q.106) According to the Fire Code of the Philippines what is the required slope of
all horizontal runs of dry standpipes system for purpose of drawing?
A. 10%
B. 20% (Correct Answer)
C. 5%
D. 2% (Your Answer)
Incorrect
Q.107) What is the minimum age requirement for an appointee to become a
member of the Board of Master Plumbers?
A. Thirty years old (Correct Answer)
B. Twenty eight years old
C. Thirty two years old
D. Thirty five years old (Your Answer)
Correct
Q.108) According to Rep. Act 1378 for at leasrt how many years must the
appointee to the Board of Master Plumbers must have been actively
engaged in the trade of plumbing?
A. Ten years
B. Eight years
C. Two years
D. Five years (Your Answer)
Correct
Q.109) For at least how many working days shall a required for inspection of the
plumbing works be filed before such inspection be intended?
A. 7 working days
B. 5 working days
C. 3 working days (Your Answer)
D. 10 working days
Correct
Q.110) When permitted by DENR, which of the following below is NOT used as a
basis in determining the type of the private sewage disposal system to be
used?
A. SOIL POROSITY
B. GROUND WATER LEVEL
C. NUMBER OF OCCUPANTS (Your Answer)

D. LOCATION
Correct
Q.111) What is the minimum height of raised letters on an iron or bronze sign that
will read "CONNECTION TO DRY STANDPIPE"?
A. 20mm
B. 1/4inch
C. 25mm (Your Answer)
D. 30mm
Incorrect
Q.112) One of the Code of Ethics for Master Plumber states "Take advantage of a
salaried ____ position to complete unfairly with a practicing Master
Plumber." What is the missing word?
A. HIGHER
B. GOVERNMENT (Correct Answer)
C. PRIVATE
D. COMPETENT (Your Answer)
Correct
Q.113) What Congress of the Republic of the Philippines approved after the third
reading Rep. Act 1378 otherwise known as the Plumbing Law of the
Philippines?
A. Third Congress (Your Answer)
B. Sixth Congress
C. Second Congress
D. Fifth Congress