Sie sind auf Seite 1von 18

iPASOLINK 100

Functions, Features and System Performance

iPASOLINK Introduction

17

iPASOLINK 100 Features

6 - 42 GHz

QPSK - 256 QAM

Giga Bit Ether x 6


Ether Ring

VLAN

Hitless AMR

16-32 xE1

RSTP/MSTP

(1+0)/(1+1)

2 way

XPIC

LDPC

1X STM1

TDM Ring

Ether OAM

SYNC ETHER

iPASOLINK Introduction

IEEE 1588v2

22

FEATURES
INTERFACES - 100

4 x 10/100/1000 Base-T(X), 2 x 1000 Base -SX/LX SFP

16 x E1 main board and 16xE1 option card or 1xSTM-1 optical /electri


MSE (Multi Service Engine) 16X E1 PWE option card
SAToP (RFC4553)

ADVANCED QoS FUNCTION - 100

Enhanced QoS functions


Packet classification functions based on header information
(802.1p, IPv4 Precedence, IPv4/IPv6 DSCP. MPLS EXP

Bandwidth Management (Traffic shaping, CIR/PIR policing per port/VLA


Class mapping (4 or 8 Class queues for QoS control)
Congestion avoidance mechanism (WTD or WRED)

Flexible Scheduling (Deficit-weighted round robin or strict Priority)


iPASOLINK Introduction

18

FEATURES
ETHERNET / VLAN - 100

VLAN functions on layer 2 based carrier network

VLAN table size 256 group or option-4094 group (VLAN 1 ~4094)


Port based VLAN, tag based (IEEE 802.1Q), Provider bridge (IEEE802.1ad
Support Jumbo frame (FE < 2000 , GbE < 9600)

HYBRID SWITCHING FUNCTION-100

TDM Cross connect: max 168 x 168 E1 left and right hand
routes
Support SNCP
Packet Switching: up to 20 Gbps

Note : The number of E1 channels depend on modulation scheme and TDM capacit
iPASOLINK Introduction

19

FEATURES
COMPACT AND RELIABLE PLATFORM

Very compact and light platform for easy installation


1u IDU and 3/3.5 kg ODU with GUI LCT for easy setting up
Backward compatible with Pasolink NEO series ODU
High reliability and quality backed by excellent field proven MTBF
Low Power consumption: adoption of high efficient RF components
VERSATILE RADIO SECTION

High modulation up to 256 QAM for Native Ether and native TDM
High system gain using LDPC FEC and Linearizer techniques
Adaptive modulation Radio (AMR)
cross polarization interference canceller. (XPIC)
Double transmission capacity up to 920 mbps in 56 MHz BW
Enhanced system gain with new ODU (IHG)
FREQUENCY AGILITY AND EASY TUNING

Field tunable local oscillators (Synthesizer)


RF Point Frequency can be changed through Local Craft Terminal (LC
ODU Sub-band changeable by simply replacing the RF Filter.
iPASOLINK Introduction

20

FEATURES
SYNCHRONIZATION

High Accuracy clock supply for clock synchronization


Support both native TDM and synchronous Ethernet for clock referen
Support external clock input / output
PROTECTION SCHEMES

E1 Ring Protection
RSTP / MSTP and Ether Ring protection
Hot Standby and Twin path for radio protection
SUPERB OAM FUNCTIONALITIES

Loopback capability Near end, far end and IF loop-backs


Ethernet OAM (IEE802.1ag / ITU-T Y.1731)
Fault detection, fault localization/isolation,
NETWORK MANAGEMENT SYSTEM

Three management systems are supported (PNMSj, PC-MG, MS5000


Web based local craft terminal for local and remote NE access
iPASOLINK Introduction

21

Capacity, Modulation & Bandwidth


Band width/
Modulation

Mode 1
7 MHz

Mode 2
14 MHz

Mode 3
28 MHz

Mode 4
56 MHz

QPSK
16 QAM
32 QAM
64 QAM
128 QAM
256 QAM

Radio Transmission
capacity Mbps
HC
HSG
10
9
22
19
27
24
33
30
39
35
45
40

Radio Transmission
capacity Mbps
HC
HSG
22
19
45
40
56
50
67
60
79
70
90
80

Radio Transmission
capacity Mbps
HC
HSG
45
40
91
81
113
101
136
121
159
142
182
162

Radio Transmission
capacity Mbps
HC
HSG
91
81
183
163
228
204
274
245
320
286
366
327

HSG-High System Gain

HC- High Capacity

Available Bandwidth and Modulation according to the Capacity key


256
128
64
32
16
QPSK
10
7MHz 14MHz 28MHz

128
64
32
16
QPSK
56MHz

Capacity key 10
256
100
128
50
100
150
64
50
100
150
32
50
50
100
16
20
50
100
QPSK
10
20
50
100
7MHz 14MHz 28MHz 56MHz

Capacity key 150


TOPC-E4048E-02

7MHz

20
10

14MHz

20
28MHz

56MHz

Capacity key 20

256
100
200
128
50
100
150
64
50
100
150
32
50
50
100
200
16
20
50
100
200
QPSK 10
20
50
100
7MHz 14MHz 28MHz 56MHz

Capacity key 200

256
256
128
50
64
50
32
50
50
16
20
50
QPSK
10
20
7MHz

14MHz

28MHz

256
128
64

50
56MHz

100
100
100
50
50
20
14MHz

150
150
100
100
50
28MHz

200
300
300
200
200
100
56MHz

Capacity key 300

iPASOLINK 200 WEB LCT

100
100
100

32
50
50
100
16
20
50
100
QPSK
10
20
50
100
7MHz 14MHz 28MHz56MHz

Capacity key 50
256
128
50
64
50
32
50
16
20
QPSK
10
7MHz

50
50

Capacity key 100


256
128
64
32
16
QPSK

50
50
50
20
10
7MHz

100
100
100
50
50
20
14MHz

200
150
150
100
100
50
28MHz

400
300
300
200
200
100
56MHz

Capacity key 400

25

Capacity, Modulation & Bandwidth AMR

Radio Configurations - Nodal


Site-F

Site-C
Site-A
Site-B

2 way Nodal
Configurations
in one IDU
iPASOLINK 200)
iPaso 200
Site-D

iPaso 400
iPaso 400
iPaso 400
Site-E

NEO/c

4 way Nodal Configurations in


one IDU (iPASOLINK 400)
iPASOLINK 400

modem : standard operate with iPASOLINK

iPASOLINK Introduction

23

Baseband Configurations
STM-1

2 x STM1

2 x STM-1

STM-1

All IP

MSE (PWE) card


MSE(PWE) card
16 x E1

E1 + Ether

(Dual Native)
FE
16 x E1

PWE

GbE

16 x E1

GbE
16 x E1

152 E1

Native TDM + Native Ether


STM-1 (63E1)x2
STM-1 (63E1)

16 x E1

16 x E1

Super PDH

16 x E1

FE/GbE
16 x E1

iPASOLINK Introduction

24

iPasolink Radio using NEO ODU


PDH

NHG2

NHG2

NEO IDU

PASOLINK NEO PDH


16 x E1

16 x E1

79 E1

NHG2

NHG2
STM-1 (63E1)

STM-1 (63E1)

Replace NEO IDU with iPASOLINK


16 x E1

79 E1 + LAN

16 x E1

NHG2

NHG2
STM-1 (63E1)

FE/GbE 16 x E1

STM-1 (63E1)

Replace NEO IDU with iPASOLINK

iPASOLINK Introduction

16 x E1
FE/GbE

25

Dual Ring Protection in iPasolink


Ethernet Ring protection
- Protection Switching Time
<2s (RSTP)
< 50 ms ERP (ITU-T G.8032v2)

TDM Ring protection


- E1 SNCP
- Protection Switching Time
<50ms

Ethernet Ring
TDM Ring

63 x E1

63 xE1

63 x E1

63 x E1

E1
63xE1(400)

Channelized STM-1

ERP - Ether Ring Protection

(200/400)

26

32xE1(200)

iPASOLINK Introduction

26

iPASOLINK 100 Block diagram

Native TDM line


E1 INTFC

MODEM

DXC

To ODU

16 x E1
(option)
Channelized
STM-1 / STM-1
(option)
Multi service
Engine
(option)

(option)

Native
Packet line

MUX/DEMUX

L2 SW
LAN INTFC

Optional
ALM / AUX

Optional
Clock

CPU
ALM/SC/CLK

-48V

Optional
Power input

options

iPASOLINK Introduction

Power
Supply

FAN Module

27

iPASOLINK 100 -Slots and Module configuration


No universal slot

2 x Fast Ether OR 2 FE + 2 GbE


4x 10/100/1000Base-T Option
ODU Interface
(1+0)/(1+1)/XPIC)

LED Indication LCT / NMS LAN Ports


(Status/Alarms)

Main Board Not


Changeable
USB Memory Slot

NE1 - LAN
Back-to-Back
2 x GbE
NE2-serial

(All units are to be fixed before Shipment)

OPTION CARDS
16 x E1 INTFC
Ch STM-1 (or STM-1)
AUX HK DI/DO Multi Service Engine

ALM
SFP/ SC/CLK

16 x E1 INTFC

iPASOLINK Introduction

PS input

Power Supply

FAN Unit

28

iPASOLINK -100 MODULES

2FE or 4 X GbE (elect)


16- xE1

2 x GbE (LX/SX)

1X CH STM1

16 X E1

1 x STM-1

AUX (option)

PWE

Option

FAN

-48 VDC PS
AUX: HK,

PS (Option)
FAN

MAIN Board

COMPONENTS
iPASOLINK 200

MAIN BOARD

MODULE NAME

Remarks

CHASSIS

CHASSIS WITH MAIN BOARD

Required

FAN MODULE

AIR COOLING FAN

Required
E116CH + GBE (2XSFP SX / LX / T)

MAIN BOARD

FIXED

+ 2FE OR OPTIONAL 4 X GbE

OPTION

1000BASE-SX

GbE Optical SX

SFP

1000BASE-LX

GbE Optical LX

SFP

1000BASE-T

GbE Electrical

SFP

16E1-S

E116ch

Option slot

STM1-S

Channelized STM-1 or STM-1 Interface

Option slot

MSE-S

TDM PWE

Option slot

CLK2M-C

Clock module (for SYNCE, SNCP and Channelized STM-1)

AUX-S
PS-S

EOW, HK, CLS

AUX Option

-48V DC external line inlet)

PS In

iPASOLINK Introduction

29

Physical location of the Option modules


Top Cover to be removed for installation
Option-2

Option-1

Option-3

GbE SFP (Port-5/6)


AUX-S

16E1-S

PS-S

STM1-S

Top Cover to be removed for installation


STM-1 SFP
Optical S-1.1
Optical L-1.1

CLK2M-C

Option-4

iPASOLINK Introduction

Electrical

30

iPASOLINK 100 IDU- INDICATORS & SWITCHES


INDICATE MAINTENANCE ON STATUS

ETHER PORT 1 LINK STATUS

INDICATE IDU ALARM STATUS

ETHER PORT 2 LINK STATUS

INDICATE ODU2 RX STATUS

ETHER PORT 3 LINK STATUS

INDICATE ODU1 RX STATUS

ETHER PORT 4 LINK STATUS

INDICATE ODU2 TX STATUS

ETHER PORT 5 LINK STATUS

INDICATE ODU1 TX STATUS

ETHER PORT 6 LINK STATUS

TX1 TX2 RX1 RX2 ALM MAINT

ORDER

WIRE CALL BUTTON

PROTECT SWITCH
ODU1 POWER ON / OFF SWITCH
ODU2 POWER ON / OFF SWITCH
BLINKS-CABLE OPEN OR ODU CPU FAILURE

iPASOLINK Introduction

31

1 Vbus
2 D (-)
3 D (+)
4 Ground
(USB) Type1

iPASOLINK 200 IDU INTFC pin assignments

1 NMS TXD(+)

1 NMS TXD(+)

2 NMS TXD (-)

2 NMS TXD (-)

3 NMS RXD (+)

3 NMS RXD (+)

4 Not Connected
5 Not Connected

4 Not Connected
5 Not Connected

ALM/SC/CLK (High Density D-Sub 44 Pins, Female)


1 ALM2 OUT (NO)
2 ALM1 OUT (NO)
3 GROUND
4 V.11-1 Data in(+)
5 V.11-1Data in(-)

16ALM2 OUT (COM)


17ALM1 OUT (COM)
18 Ground
19 V.11-1 clock in(+)
20 V.11-1 clock in (-)

31 ALM2 OUT (NC)


32 ALM1 OUT (NC)
33 V.11-1 FP input(+)
34 V.11-1 FP input(-)
35 V.11-1 FP output(+)

6 NMS RXD (-)

6 NMS RXD (-)

7 Not Connected

7 Not Connected

6 V.11-1 Data out(+)

21 V.11-1 clock out(+)

36V.11-1 FP output(-)

8 Not Connected

7 V.11-1Data out(-)

22 V.11-1 clock out(-)

37V.11-2 FP input(+)

8 Not Connected
LCT / NMS (RJ-45)

8 V.11-2 Data in(+)

NE1 (RJ-45)

9 V.11-2Data in(-)

23V.11-2 clock in(+)


24V.11-2 clock in (-)

38V.11-2 FP input(-)
39V.11-2 FP output(+)

10 V.11-2 Data out(+)

25 V.11-1 clock out(+)

40 V.11-2 FP output(-)

11 V.11-2 Data out(-)

26 V.11-1 clock out(-)

41 RS-232C-2 Data in

12 RS-232C-1Data in

27 Ground

42 RS232C-2 data out

13 RS-232C-1Data out

28

43 EXT1 CLK in (-)

14 EXT1 CLK in(+)

29 Ground

44 EXT1 CLK OUT(-)

15 EXT1 CLK OUT(+)

30 NC

iPASOLINK Introduction

32

Das könnte Ihnen auch gefallen