stelmec

GR

boundaries

ID & PO
WE

R IT

SMA R T

beyond

SLR JH13
MASTER TRIP RELAY

The Stelmec make Master Trip Relay SLR JH13 is an Electromechanical High Speed Tripping Relay used
in tripping and signaling circuits of protective relays, where a high degree of reliability & high contact
rating is required. It is an instantaneous switching element that is used for Contact multiplication of
Protection relays of Circuit Breakers, thereby providing number of simultaneous instantaneous
switching operations.

Salient Features

Conforms to IS 3231:1981
High Speed Operation
Electro Mechanical Design
Hand Reset Contacts
Hand Reset Mechanical Flag
Heavy Duty Contacts: 1250 VA
10,000 Mechanical operations
Flush Panel Mounting
2 elements and 3 elements relay also available
Dimensions

Front Bezel: 15292 mm


Cut Out: 13072 mm

stelmec

SLR JH13

beyond

boundaries

Description
A fast operating, multi-contact, attracted armature relay with a

The Mechanical interlock operates & Relay remains in lock out

high degree of mechanical stability, Type SLR JH13 has

position until it is hand reset.

hand-reset contacts and an operating coil cut-out contact.

A mechanically operated hand reset type flag, is provided as an

The control coil of the relay element is wound with super

operation indicator. White for reset position & Red for Lock out

enamelled copper wire with a short time thermal rating so that

indication.

the relay has a very fast operation with operation time < 10ms.

The contacts are designed to have superior contact rating with

A coil cut-off contact (NC contact of same element) with

minimum wear and tear.

suitable break rating is internally wired in series with the coil.

The elements are mounted in compact, non-drawout case,

This makes coil operation momentary & disconnects the coil on


operation.

suitable for flush mounting on panels.

Technical Specifications
Coil Rating

24/30, 110, 220V DC/AC

Operating Range

50 to 120% of rated voltage

Operating Time

<10 ms at nominal rated voltage

Rated Burden

<45 Watts

Operational Indicator

Mechanical flag (HR type)

Mounting

Flush

Contacts

Upto 7 pair combinations (NO/NC)

Standards

IS 3231:1981

Make & Carry

Make & Carry for 3 sec.

Break

AC

1250 VA with max. of 5A & 660 Volts

7500 VA with max. of 30A & 660 Volts

1250 VA with max. of 5A & 660 Volts

DC

1250 W with max. of 5A & 660 Volts

7500 W with max. of 30A & 660 Volts

100 W Resistive, 50 W Inductive


for 5A / 660V

Wiring Diagram

Terminal Arrangement

There is a continuous effort at Stelmec to keep abreast of latest technology inline with customers requirement.
All these activities are followed as per ISO 9001 : 2008.
Contact:
SBU: Stelmec Limited, Power IT Solution Division, Plot No. 14/15, Western Express Highway No. 8, Sativali, Vasai (E), District: Thane - 401 208.
Tel. No. +91-250 6452377/6454150
CORPORATE: Stelmec Limited 'Sea Queen', 43-A, H.K. Bhabha Road, Bandstand, Bandra (W), Mumbai - 400 050.
Tel: +91 22 2643 6127 / 28 / 29 | Fax: +91 22 2643 6139 | E-mail: corporate@stelmec.com

website: www.stelmec.com