SOLAR INVERTER

OFF-GRID 3KVA-8KVA

GFK11 Series Products use high speed DSP Control Unit, Advanced
high speed IGBT, MOSFET components, with Pulse Width
Modulation (SVPWM) technique disturbance type MPPT Control,
and double conversion system conguration. Under high-speed
DSP system control, the system can quickly track panels to do
high-power, load change and ecient multi-level control system,
even if the mains input voltage and frequency suddenly changes,
over/under voltage, or power disturbances. It also can provide the
load with regulated voltage and frequency power. System has a
reliable, environmentally friendly, high intelligence and other
characteristics.

HIGH RELIABILITY:

- High-speed micro-controller DSP digital control technology to achieve real-time control, parameter setting, data
detection, self-test function to ensure high reliable operation of the system.
- With high speed switching characteristic, high voltage, high current, low internal resistance, low dissipation IGBT,
MOSFET power components based, to ensure system security and reliability.
N+1 MODULARISED MPPT TRACKING SYSTEM:

- Multipath MPPT control system access, independent input, operation. More suitable for roof project, to improve
power generation eciency of the panels.
PV PROACTIVE POWER SUPPLY FUCNTION:

- After detects PV energy, system will enter MPPT status automatically and it will also adjust the power distribution,
priority in the use of PV energy.
INTELLIGENT BATTERY MANAGEMENT SYSTEM:

- In this system, AC rectier, MPPT controller controlled by intelligent data exchange and communication system,
user can set battery capacity by themselves; battery conguration can be set by the operation interface, system will
automatically adjust the charging current, charging voltage, and charging mode.
- In special cases, International Technical Engineer can adjust the charging rate and battery number according to
the system conguration.
PLENTEOUS COMMUNICATION INTERFACE:

- RS485, RS232 (standard) and SNMP (optional)


- Input dry contact to switch on/o inverter, clear abnormal, EPO remotely. Output dry contacts singles for remote
alarm.
PLENTEOUS COMMUNICATION INTERFACE:

- system with intelligent peak load and shifting function, the user can set the appropriate time period electricity
according to the local electricity policy, to achieve load shifting features directly in order to bring economic value.

OFF GRID 3KVA-8KVA


Solar Inverter
TE CHN I CAL SPECIFICAT ION
MODEL
RATED POWER (KVA)
RATED POWER (KW)

SNV-GF
3K08

SNV-GF
4K08

SNV-GF
3K16

SNV-GF
5K16

SNV-GF
6K16

SNV-GF
8K16

3 KVA
3 KW

4 KVA
4 KW

3 KVA
3 KW

5 KVA
5 KW

6 KVA
6 KW

8 KVA
8 KW

OUTPUT POWER FACTOR

192 VDC

96 VDC

BATTERY VOLTAGE

PV priority / AC priority optional

WORKING MODE

PV INPUT
MPPT VOLTAGE RANGE
MAX. CHARGING CURRENT (A)

96 VDC - 200VDC
10 - 60 A

PV PANELS CONF. (SUGGESTIONS) (VMP)

120 - 142 VDC

PV PANELS CONF. (SUGGESTIONS) (IMP)

< 60 A

192 VDC - 400 VDC


10 - 60 A

10 - 40 A

192 VDC - 400 VDC


< 60A

< 40A
98%

CONVERSION EFFICIENCY

DISPLAY
LCD + LED

PANEL INDICATOR

AC MODE
165 VAC - 275 VAC

INPUT VOLTAGE RANGE

40 - 70 HZ ( Auto Transfer to Battery Mode, if out of range )

INPUT FREQUENCY RANGE

220 VAC 5%

OUTPUT VOLTAGE PRECISION

> 0.8

INPUT PF (AC/DC)

88% Inverter On

MAX. EFFICIENY
OVERLOAD

110 Transfer to bypass in 255s ; 120% transfer to bypass in 60s ; 150% transfer to bypass in 10s
8A / 12 A

MAX. CHARGING CURRENT


SHORT CIRCUIT PROTECTION

ELECTRONIC LIMITED CURRENT OUTPUT OR TURN BYPASS; AIRBREAKER PROTECTION

INVERTER MODE
220 VAC5%
50 / 60 Hz 1% frequency self adjusted

INVERTER OUTPUT VOLTAGE


OUTPUT FREQUENCY

1
< 5% linear load

OUTPUT POWER FACTOR


DISTORTION

0 ms

PV-AC TRANSFER TIME

> 92%

MAX. EFFICIENCY
OVERLOAD
ECO MODE ( OPTIONAL)
SHORT CIRCUIT PROTECTION

110 Trnsfer to bypass in 255s ; 120% transfer to bypass in 60s ; 150% transfer to bypass in 10s
Load <5% System automatically shut down at 1 Min. Transfer to bypass power supply
ELECTRONIC LIMITED CURRENT OUTPUT OR TURN BYPASS OR SHUTDOWN

ALARM
1/4s ; Automatically sound elimination after 40s

AC FAIL
BATTERY LOW VOLTAGE

5/1 s

OVERLOAD

1/1 s

COMMUNICATION
RS232 / USB / RS485 / SNMP

COMM. INTERFACE
DRY CONTACT

PV FAILURE, Battery Low Voltage, Overload, Bypass, Inverter Failure, Remote Start Generator Dry Contact signal

OTHERS
Terminal Blocks
Optional

OUTPUT CONNECTION
SURGE PROTECTION

Accord with EN62040-2 ; 2006 ; en61000-3-2 ; 2006 ; en61000-3-3 ; 2008

EMC

ip 20

IP CLASS

0 c - 40 c

AMBIENT TEMPERATURE

10% - 90% ( non condensing )

AMBIENT HUMIDITY

< 50 dB
2000m ( Every 100 increase, derate 1% )

NOISE
WORKING ALTITUDE

560 x 265 x 725

DIMENSION ( W x D x H ) mm

662 x 360 x 905

PACKING DIMENSIONS ( W x D x H ) mm
WEIGHT
PACKING WEIGHT

76
85

80
89

60
69

67
76

69
78

Distributed by: