ARCHITECTURAL ACOUSTICS

Unit 3
NOISE CONTROL AND SOUND ABSORPTION
Types of noises, transmission of noise, transmission loss, noise control and sound insulation, remedial
measures and legislation.

What is NOISE?

All sounds that are distracting annoying or harmful to everyday activities are regarded as
NOISE.

ANY SOUND JUDGED UNDESIRABLE BY THE RECIPIENT IS TERMED AS NOISE.

Whether or not the sound is undesirable depends on the

1. LOUDNESS
2. FREQUENCY
3. CONTINUITY
4. TIME OF OCCURRENCE
5. INFORMATION CONTENT
6. RECIPIENTS STATE OF MIND
7. RECIPIENTS TEMPERAMENT.
SOUND is a sensation of acoustic waves (disturbance/pressure fluctuations setup in a medium)
NOISE TYPES:

In a building, there are 2 types of noise.

1. EXTERNAL NOISE

VEHICULAR (Motor Cars, Buses, Two Wheelers, Air Traffic, Rail Traffic)

EXPOSED MECHANICAL EQUIPMENTS

EARTH MOVING, CONSTRUCTION EQUIPMENTS

STREET VENDORS

CHILDREN PLAYING (TOT LOTS) & PLAYGROUNDS

BLARING LOUDSPEAKERS.

NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T

Page 1

THE REDUCTION OF OUTDOOR NOISE WITH DISTANCE IS GOVERNED BY THE


INVERSE SQUARE LAW.

A drop of 6db will be noticeable every time the distance between the source and recipient is
doubled. (Provided there are no reflecting surfaces near the noise source).

TYPICAL NOISE LEVELS OF TRAFFIC


TYPE

NOISE LEVEL (dB)

BOEING 707

(450M)

111

BOEING 737

(450M)

107

BOEING 747

(450M)

103

AIRBUS 4300

(450M)

101

CONCORDE

(450M)

114

STEAM TRAIN (30M)

85

DIESEL

(30M)

83

ELECTRIC

(30M)

77

ELEVATED TRAIN

120

DIESEL TRUCK (15M)

80

PASSANGER CAR (6M)

70

HEAVY URBAN TRAFFIC

70

2. INTERNAL NOISE

LOUD CONVERSATION

RADIO / T.V / MUSIC SYSTEM

DOOR BANGING

STAIRCASE TRAFFIC

CHILDREN PLAYING

HOUSE HOLD APPLIANCES

NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T

Page 2

THE NOISE LEVEL AT ANY POINT IN THE INTERIOR IS MADE UP OF 2 PARTS.

SOUND RECEIVED DIRECTLY FROM SOURCE

REVERBERANT SOUND (after repeated reflections)

Direct sound is more near the source

Reverberant sound (reflected sound) is more away from the source.

ACCEPTABLE INDOOR NOISE LEVELS FOR VARIOUS BUILDINGS:


LOCATION

NOISE LEVEL (dB)

AUDITORIA & CONCERT HALLS

20-25

RADIO &T.V STUDIOS

20-25

MUSIC ROOMS

25-30

HOSPITALS, CINEMA

35-40

APARTMENTS, HOTELS & HOMES

35-40

CONFERENCE ROOMS, SMALL OFFICES & LIBRARIES

35-40

COURT & CLASS ROOMS

40-45

LARGE PUBLIC OFFICES, BANKS, STORES

45-50

RESTURANTS

50-55

Noise may be classified as steady, non-steady or impulsive, depending upon the temporal
variations in sound pressure level.

STEADY NOISE is a noise with negligibly small fluctuations of sound pressure level within
the period of observation.

A noise is called NON-STEADY when its sound pressure levels shift significantly during the
period of observation. This type of noise can be divided into intermittent noise and fluctuating
noise.

FLUCTUATING NOISE is a noise for which the level changes continuously and to a great
extent during the period of observation.

TONAL NOISE may be either continuous or fluctuating and is characterized by one or two
single frequencies. This type of noise is much more annoying than broadband noise characterized
by energy at many different frequencies and of the same sound pressure level as the tonal noise.

NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T

Page 3

The chief sources of noise in building can be divided into 3 categories:

1. Sources associated with occupant activity and office equipments.


2. Sources associated with the operation of building services.
3. Sources of environmental sound from outside a building.

A source of noise may or may not be a source of vibration in a building.

Similar a source of vibration may or may not be a source of significant noise.

Eg: Door Slams, footfall, conversation, radios, etc.

NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T

Page 4

NOISE TYPES AND THEIR MEASUREMENT:


Noise characteristics classified according to the way they vary with time. Constant noise remains
within 5 dB for a long time.
Constant noise which starts and stops is called intermittent.
Fluctuating noise varies significantly but has a constant long term average (LAeq,T).
Impulse noise lasts for less than one second.

MASKING NOISE:

In many situation noises control problems can be solved by DROWNING (or masking)
unwanted noises by electrically created background noise. This artificial noise is often referred to
as ACOUSTICAL PERFUME OR ACOUSTICAL DEODARANT. This process suppresses
minor instruments which might interrupt the recipients privacy.

Example:-

NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T

Page 5

Noise from ventilating systems.

Uniform flow of traffic.

General office activities.

In designing landscaped offices, the provision of a relatively high but acceptable degree of
background noise is essential in order to mask undesirable noise like typewriters, office
machines, loud conversation, etc.

TRANSMISSION OF NOISE:
There are 2 paths of sound transmission between spaces:
1. Air borne Machine which excites air in the source room.
2. Structure borne Vibration from a machine to a structure.

Often the sound transmission is by both in varying quantities.

AIRBORNE & STRUCTURE BORNE SOUND

If the sound is transmitted through Air only, it is called AIRBORNE SOUND. (Example: Someone talking, A Singer, A Violin, etc.).

If the sound source not only radiates its energy through air, but also simultaneously sets into vibration of
solid parts of the building then it is called STRUCTURE BORNE SOUND (EX: - footsteps noises,
motors etc).

NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T

Page 6

AIRBORNE NOISE

Airborne noise originating in the source room can be transmitted to the receiving room in the
following ways.

1. along continuous air paths through openings, such as open windows, ventilating ducts, grilles,
shafts, crawl spaces, gaps and cracks around doors, pipes, conducts, electrical fixtures, built in
elements.
2. by means of forced vibrations setup on the boundaries of the source room (walls, floor, ceilings)
and transmit to the boundaries of the receiving room. actually, what the listener hears in the
receiving room is not a fraction of the original sound, but a reproduction of it.
STRUCTURE BORNE NOISE

Since they are readily transmitted with little attention and over great distances in a building
structure borne and vibration should be suppressed at the source or is close to the source as
possible.

This can be accomplished

1. By the use of adequately resilient flooring (carpet, rubber, tile) to reduce impact vibration
transmission into the floor.
2. By the use of flexible materials (mountings, anti vibration pads, floating floors) to prevent the
transmission of vibration and shock from various machines or exterior sources into the building.
SOUND TRANSMISSION BETWEEN ROOMS:

A sound source will develop a reverberation sound field in one room and its sound pressure level
will depend on the total absorption provided by the source room boundary wall.

Assuming the sound can travel only through the common separating wall, the transmitted sound
level will depend on:

1. Sound isolating properties of the wall Sound Transmission Loss.


2. Total surface area of the wall that radiates sound into the adjacent room.
3. Total absorption present in the receiving room.

NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T

Page 7

NOISE REDUCTION BETWEEN ROOMS:

The noise reduction NR between rooms is the arithmetical difference in sound levels Ls in
the rooms.

The reduction of sound between the rooms is given by

NR = L1 L2= TL + 10 log A2 / S

OR

NR = TL + 10 log A2 / S

L1 SPL in source room(dB)

L2 SPL in receiving room(dB)

TL Sound Transmission Loss

A2 Total Absorption in the receiving room in sabins.

S - Common wall surface area in Sq.Ft

Measurements of TL are made at several test frequencies (usually 16) between 125H z and
4000H z.

NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T

Page 8

The transmitted sound L2 will be disturbing in the receiving room if it exceeds the background
sound level in the room.

The background sound level is hence important for any sound isolation.

It is a residual sound level present.

The larger, the common wall is more sound is radiated.

The absorbing material in the receiving room will reduce built up reflected sound radiated into
the receiving room.

Hence the material of the common wall is important.

The major loss sound energy is provided by this wall / floor / ceiling, partition.

Light weight partitions / floor systems Sound Transmission Loss of 20dB.

Massive / Double construction - Sound Transmission Loss of 40 60dB.

If the barrier size S coincides with the absorption in the receiving room A 2, NR = TL.

NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T

Page 9

SOUND TRANSMISSION LOSS:

Transmission loss is a measure of how much sound energy is reduced in transmission through
materials.

The more massive a material , the higher its TL.

THE TL CAN BE DETERMINED AS FOLLOWS

TL =L1 L2

Where TL = sound transmission loss(dB)


L1 = sound level in source room(dB)
L2 = sound level in receiving room(dB)
and

TL = 10 log 1/

Where TL = sound transmission loss(dB)


= sound transmission coefficient (no units)

is the ratio of the sound energy transmitted by a material to the incident sound energy.
A steady sound is generated in the source room at one side of the partition to be tested.

Sound levels are then measured at both sides of the partition (source room & receiving room).

The TL = Difference between the 2 values.

TRANSMISSION LOSS OF SINGLE LEAF PARTITIONS:

The TL of homogenous single leaf partition depends on the SURFACE WEIGHT of the partition
& also the FREQUENCY of sound transmitted.

To achieve an effective TL a partition should be impervious to airflow

Walls of porous concrete block will not yield a TL in proportion to the weight. However the TL
can be considerably increased by sealing its exposed surface with plaster, cement based paint
etc.

TRANSMISSION LOSS IN MULTIPLE PARTITIONS:

To achieve a significant improvement in the TL value of a single leaf partition requires doubling
or tripling its mass. Such as increase in the weight and thickness of an enclosure is obviously
different to achieve for FUNCTIONAL, SPATIAL, STRUCTURAL, AND ECONOMIC
REASONS.

NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T

Page 10

If a high degree of sound insulation is required, it is therefore advisable to use multiple


partitions built of 2 or 3 separate leaves.

Multiple partitions provided a higher TL than would be expected out of their weight, particularly
at the higher frequencies of the following precautions is observed:

1. The total weight has been established as a reasonable maximum.


2. The separation between the leaves has been consistently secured.
3. A maximum distance has been established between the leaves.
4. A continuous layer (or patches) of sound absorbing material have been mounted in the air space.
5. The leaves have been built of either different materials or different thicknesses of the same
material.
6. The leaves have been resiliently attached to the studs.
7. Noise leaks are completely avoided (particularly around perimeter edges).
8. The stiffness of the partition has been so established that it minimize the coincidence effect.
Sound insulation increases with ..
1. Increased weight
2. Wide spacing of studs
3. Studs (Ties) Eliminated
4. Staggered studs
5. Two levels of different weight
6. Resilient attachments
7. Max. separation between 2 leaves
8. Isolation blanket in Air space
9. Perimeter caulking

NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T

Page 11

COMPOSITE BARRIERS

If a door, window, or other opening is to be incorporated into a wall, the eventual overall sound
insulation of the resulting COMPOSITE PARTITION is determined primarily by its weakest
element.

NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T

Page 12

MATERIALS OF CONSTRUCTION:
1. Single Homogenous Wall:

The average TL increases with weight.

2 Plaster Wall 35dB

4 Plaster Wall 40dB

6 Plaster Wall 45dB

2. Double Walls:

If the 2 plaster wall is split into two 1 leaves separated by a 3 air gap, the average TL would
be 8dB . Large air spaces is required to achieve significant improvement.

Air space < 1.5 does not yield much improvement

Ideal separation is 12

Avoid rigid ties between the panels.

TL of
Construction

125 Hz

250 Hz

500 Hz

1000 Hz

2000 Hz

4000 Hz

8000 Hz

12 painted
concrete block
wall with sand
filled cells

33

40

47

33

59

65

51

6 concrete block
+ 6 airspace + 6
concrete block

38

47

58

68

78

85

59

3. Absorption in Double Constructions:


Addition of sound absorbing materials within the cavity of the double wall construction Fibrous, glass,
mineral wool insulation materials can increase overall sound energy loss Provides a MUFFLER
LIKE effect to reduce sound transmission.
4. Composition Constructions:
Common walls are made up of more than one component

Doors, windows, Partition elements etc.

NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T

Page 13

SOUND TRANSMISSION CLASS STC:

STC is a single value (dB) calculated by matching the mid frequency bands TLs of a given
construction to a standard curve.

The STC of a construction is useful in determining the effectiveness of a partition in


reducing speech noise, similar to the NRCs application to absorption in the speech range.

Note that the actual reduction is 5-10dB less than the STC, so you must compensate for this if
you have a specified isolation required. If a specification calls for a certain STC, then this is
already considered.

NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T

Page 14

TO DETERMINE THE STC OF A GIVEN SPECIMEN:

Measured TL values are plotted against frequency.

Compare with a reference contour.

Using a transparent overlay on which the STC contour is drawn, the STC is easily determined.

The STC contour is shifted vertically relative to the test data curve to as high a position as
possible.

When the STC contour is adjusted to the highest position that meets the below requirements, the
STC rating is read from the vertical scale of the test curve as the TL value.

The value corresponding to the intersection of the STC contour and the 500Hz ordinate.

CONDITIONS:

The maximum deviation of the test curve below the contour at any single test frequency shall not
exceed 8dB.

The sum of the deviations at all 16 frequencies of the test curve below the contour shall not
exceed 32dB.

NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T

Page 15

EXAMPLE OF READINGS:

STC ratings reflect the significance of deficiencies such as the dip in construction Bs TL curve.

Bs STC 33 rating, indicated in the graph is governed by the 8dB deviation below the contour at
1000Hz. Although its total deviation is well under 32 dB.

Construction A has an STC 43 rating also shown in the graph.

Field Sound Transmission Class ( FSTC ) : a single STC value (dB) of a construction measured with
in-situ conditions; sometimes this is considered a more realistic estimate, but usually there is little
information on the specifics of the field condition itself, so it may be hard to reproduce.
NOISE CRITERIA CURVES:

The octave band spectra of background sound in buildings follow NC curve.

The NC curve is the most widely used means for specifying criteria and evaluating background
sound in buildings.

RECOMMENDED NOISE CRITERIA FOR ROOMS:

The noise criteria NC curves can be used as a method for specifying continuous background
noise levels to achieve sound isolation.

NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T

Page 16

NO

TYPE OF SPACE & LISTENING


REQUIREMENTS

PREFERRED RANGE EQUIVALENT


OF NC
DB LEVEL

Concert halls, opera houses, recording


studios

NC15 TO NC-20

25 - 30

Bedrooms, sleeping areas, hotels, residences

NC20 TO NC-30

30 40

Auditoriums, theaters, churches, conference


rooms

NC20 TO NC- 30

30 40

Offices, classrooms, libraries

NC30 TO NC35

40 45

Gyms, restaurants

NC35 TO NC- 40

45 50

Labs, Engg.rooms, lobbies

NC40 TO NC45

50 55

Kitchens, schools, garages

NC45 TO NC-55

55 - 65

NC CURVE

63

125

250

500

1000

2000

4000

8000

NC 70

83

79

75

72

71

70

69

68

NC 40

64

57

50

45

41

39

38

37

NC 20

50

41

33

26

22

19

17

16

NC 15

47

36

29

22

17

14

12

11

EACH NC CURVES IS DEFINED BY ITS SPL FOR THE 8 OCTAVE BAND FREQUENCIES

SIX FACTORS THAT INFLUENCE SPEECH PRIVACY BETWEEN ENCLOSED ROOMS:


1. Background sound level in listeners space receiving room.
The background sound in a receiving room acts to mask unwanted speech sounds and renders them
less intelligible.
2. Strength of sound source vocal effort.
The louder the speech signals, the more intelligible it is in the receiving room.
3. Amount of sound absorption in receiving room.

NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T

Page 17

The less reverberant buildup of speech sound in the receiving room, the lower the speech signal
level, and the less the speech intelligibility.
4. Relative sizes of source and receiving rooms.
The larger the receiving room relative to the source room, the lower the speech in the receiving
room.
5. Sound transmission characteristics of intervening construction separating 2 spaces. The higher
the sound transmission loss TL of the wall, the lower speech signal in the receiving room.
6. Required speech privacy.
The higher the rating, the lower the speech signal must be relative to the background sound level in
order to ensure adequate masking of speech signals to minimize speech intelligibility.
FACTORS THAT INFLUENCE SPEECH PRIVACY IN OPEN PLAN SPACES:

The open office landscape has become increasing popular for large corporations. The basic
acoustical problem is really no different from the case of adjacent enclosed spaces.

Adequate privacy requirements are as follows:

Sufficient attenuation of the speech signal from the source to the listener location.

Speech effort and speaker.

Masking by the continuous background sound present.

The containment and buildup of reverberant sound is nor present in open plan spaces. Sound in
the open space continually falls off with distance at a rate dependent on the sound absorption of
the floor / ceiling surfaces.

Noise barriers reduce the sound at the receptor location if they break the direct path between the
source and receptor.

Speech Privacy required as in enclosed spaces.

Distance from source to listener.

NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T

Page 18

NOISE CONTROL:

In a building, there are 2 types of noise.

External noise and Internal noise.

EXTERNAL NOISE

Distance.

Avoiding zones of directional sound.

Screening.

Planning using noise sensitive parts of the building as barriers.

Positioning of openings away from the noise source.

Noise insulation building envelope.

INTERNAL NOISE

Reduction at source.

Enclosing and isolating the source use of absorbent screens.

Planning separating noisy spaces from quiet spaces.

NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T

Page 19

Reducing impact noises by covering surfaces with resilient materials.

Placing noisy equipment in the most massive part of building basement.

Reduce noise in space where it is generated by the use of absorbent materials.

Reduce airborne sound transmission by airtight and noise insulation construction.

Reduce structure borne transmission by discontinuity.

MEANS OF NOISE CONTROL:


1. DISTANCE AND SCREENING

Location of a building on a site as far from the noise source as possible. Every doubling of the
distance will reduce the noise level by 6dB, etc.

Example:- 65 dB noise: 59dB 10m, 53dB 20m, 47dB 40m.

Screening effort of walls, fences, plantation belts.

Any given barrier will be effective when it is as near the source as possible, or near the building
to be protected.

2. PLANNING

Separating areas which are not noise sensitive, where noise would not cause disturbance and
placing them on the side of the building near noise source.

Positioning and orienting major openings away from the source.

In a building, the weakest points for noise penetration are the openings.

Plan shape to provide screening from the sides.

Addition of special elements for protection wing walls, screens.

3. REDUCTION AT OR NEAR SOURCE

Machine vibration place the machinery on flexible mountings so the vibration is not
transmitted.

The resonant frequency of the mounting itself must be lower than the frequency of vibration to
be isolated.

Airborne sound emitted tackled near the source.

The source could be covered by an insulating enclosure box.

The box could be of massive construction with absorbent lining on the inside, to prevent the
buildup of reverberant noise level.

NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T

Page 20

Could be removable or have any transition between the full enclosure and a simple screen to
reduce noise emission.

4. REDUCTION WITHIN A SPACE

Direct noise placing a screen between the source and the listener

Reverberant noise use of absorbent materials on critical surfaces of the room.

Absorbent qualities of different materials vary with the frequency.

Porous higher frequencies.

Membrane low frequencies.

Resonant tuned to a very narrow band of any frequencies.

Perforated panel absorbers combination of resonant and porous medium frequency. Can be
tuned by variation of whole size, shape and placing and backing material and space.

The ceiling is the most critical surface as it causes multiple reflections of the sound.

Also as most absorbents are vulnerable to damage, the least exposed surface to mechanical
damage is the ceiling.

5. NOISE INSULATION

Depends on transmission coefficient and transmission loss TL.

For solid, homogeneous walls the insulating quality is a function of the mass.

The doubling of the wall mass increases the TL by 5dB.

STRUCTURE BORNE SOUND:

In structure borne sound, it is the effect of the solid coupling mechanism between the source and
hearer which is important.

The coupling between the source of vibration and the solid structure.

The type of vibration waves produced in the solid.

The coupling with the fluid at the hearing.

Coupling Loss Factor CLF the fraction of energy transmitted from one system to another in
one radian cycle and has the same meaning as the loss factor in mechanical systems.

NOISE CONTROL MEASURES:

A noise control program should involve the following:

NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T

Page 21

Preparation of a noise map after taking measurements in all areas.

The setting of target noise levels for all areas.

A description of all measures planned a cost analysis, and the attenuation expected.

The setting of priorities within a plan to achieve the agreed targets, stating start and finish times.
OUTDOOR BARRIERS FOR NOISE CONTROL

Better

Best

NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T

Page 22

NOISE REDUCTION FROM OUTDOOR THIN WALL BARRIERS

SELF PROTECTING BUILDING FORMS

NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T

Page 23

BALCONIES AND OVERHANGS

EARTH BERMS

ATTENUATION FROM VEGETATION


NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T

Page 24

ORIENTATION OF BUILDINGS

NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T

Page 25

ATTENUATION OF STRUCTURE BORNE SOUND:

Preventing transmission of vibration from machines and equipments to the load bearing structure
of the building using the following principles:

1. Vibration isolates machines with stiff or independent frames. Place the machine on a stable
foundation with an elastic separating layer rubber stocks or steel springs.
2. Place large heavy machines which cannot be effectively vibration isolated, on special machine
foundations which are completly separated from the building.
3. Vibration isolated machine panels mounted on the machine frame or coated with special
damping material to reduce vibration level transmitted to them.
NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T

Page 26

Severely vibrating machines requires separate foundations and isolating joints between floor
slabs to prevent the propagation of structure borne noise.

a) Before casting the floor, a thick strip of foamed plastic is placed in all the joints between the
floor and rest of structure.
b) After the floor is cast, the foam is pulled or burnt out, the joint inspected and cleaned. There
must be no bridging between the joints.
c) The joints is then filled with a flexible material synthetic rubber tube and sealed completely
with an elastic material of high density.
SOUND INSULATED ROOMS:

Automatic machines present with remote control of the process.

1. Build control and monitoring rooms with good sound insulating properties.
2. Well sealed door and window designs.
3. Provided ventilation openings with attenuators or acoustic louvers and ensure cables pipe cuts
are filled acoustic sealant.
GUIDELINES AND REMEDIAL MEASURES:
PLANNING THE BUILDING

The acoustically important details of the building load bearing structure and work areas should
be calculated and fixed early in the planning stage.

The need for noise control depends first on the way production plant is designed.

The structural design of the building depends on where the machinery is placed and the need for
insulation against air borne and structure borne sound.

1. The buildings load bearing structure, floors, and machine foundation should be chosen so that
sources can be effectively vibration isolated. Heavy equipments demand stiff and heavy
foundations, which must not be in direct contact with other parts of the structure.
2. Powerful noise sources should enclosed by structures which give adequate airborne sound
insulation. Doors, inspection windows and other building elements where there is a risk of sound
leakage required special attention.
3. Rooms where there are sound sources or where personnel are present should be provided with a
ceiling cladding which absorb the incident sound.
4. Office areas should be separated from building elements where vibrating material is installed by
a joint of elastic material.

NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T

Page 27

5. Walls, ceiling construction, windows, and doors should be chosen so as to achieve the required
sound insulation.
6. In open office plans, and large rooms where there are several office functions carried out in the
same room, there must be a ceiling with sound absorption, and soft carpeting on the floor. It is
important that there is sound absorption at low frequencies.
GUIDELINES AND REMEDIAL MEASURES:
NOISE REDUCTION MEASURES IN ROOMS

The shape and size of an industrial workshop is determined by the production processes and flow
of materials.

Guidelines for the layout of a new plant are as follows:


1. Workstations and machines should be so placed that the reduction of noise with distance can be
exploited a certain distance between noisy and quieter areas. Ensure a space is allowed
between screens and partitions.
2. Ensure that separate areas are available for particularly noisy machines basement.
3. Work which requires a quiet working environment or which does not itself produce noise should
be removed to a region with a low noise level work. Where possible mount absorbent ceilings in
such areas.
4. If noisy work is carried out close to a wall or any other reflective surface, it should be covered
with an absorbent material.
5. Workshop offices, rest rooms etc should be provided with sufficient sound insulation and
possibly mount on isolators, or separated from the rest of the building structure by flexible joints
to avoid vibration transmission.
6. Fixed installation ventilation equipment, cooling systems should be constructed with sound
attenuation in mind, and mounted so that sound from fans etc is prevented from spreading via
ducts, pipes and the building structure itself.
7. In open office plan and large rooms, work areas must sometimes be located bearing in mind that
noise occurs from certain processes while a relatively noise free environment is required for
others for conversation.

NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T

Page 28

ACOUSTICAL DEFECTS CAUSES AND REMEDIES


NO.

DEFECT

CAUSES

ADVANCE IN DESIGN REMEDY FOR


EXISTING BUILDINGS

1.

Excessive
reverberation

Excessive volume

Keep volume limited to


100-150 cu.ft per seat. Use
of more absorbent
materials on distance
surfaces.

Increase seating or increase


interior surface by bold
decoration in relief. Use of
more absorbents.

2.

Echoes

Unsuitable shape

Avoid curves.

Alter shape.

Distant reflecting
surfaces

Make distance surfaces


highly absorbent.

Use absorbing materials on


offending surfaces. Make
distant surfaces highly
absorbent.

3.

Interference

Undiffused reflection
of sustained note

Design bold breaks in


Add bold decorative or
walls and ceilings. Use
resonating covering or both.
resonating wall coverings.

4.

Unsatisfactory
sound volume

Excessive volume

Provide hard reflecting


surfaces about the origin.

Provided hard reflecting


surfaces

Adjust absorption to
obtain optimum
reverberation.

Adjust absorption to obtain


reverberation.

Leak of reflection
Excessive absorption

Provide just sufficient


absorbing surface.
5.

Distortion

Use of selective
absorption
Screening at higher
frequencies

6.

resonance

Replace part absorbent


surfaces by reflection
surfaces.

Use mixed absorbents to


obtain uniform
coefficients.
Avoid screening sound.

Uncontrolled
resonance

Select board absorbents


which resonate over a
wide range and fix on
battens at irregular
intervals.

Flimsy partitions and


linings

Adopt rigid construction at Stiffer partitions and linings.


irregular spacing.

NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T

Page 29

INSULATION AGAINST STRUCTURE BORNE NOISE:

Insulation against structure borne (or impact) noise can be achieved by the use of:

1. Soft floor finish (carpet, cork, vinyl, rubber, etc).


2. Floating floor.
3. Resilient (anti vibration) mounts.
4. Resiliently suspended solid ceiling.

The addition of a soft floor finish does not provide extra insulation against airborne noise but
merely reduces or eliminates impact noise such as footstep noise, at the source.

On the other hand, a floating floor or a resiliently suspended ceiling also improves the airborne
sound insulation in floor assemblies.

NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T

Page 30

MEASUREMENT OF STRUCTURE BORNE NOISE:

The measurement of structure borne noise is different from that of airborne noise. According to
the recommendation of the ISO, the insulation against impact noise. Provided by a given floor
must be determined by means of a standard tapping machine, which provides a series of
uniform impacts at a constant rate on the floor being tested by means of fine small hammers,
which fall freely at a specified rate on the floor.

The sound pressure level of the impact noise transmitted into the receiving room, beneath the
floor, are measured with a sound level meter in sixteen 1/3 octave bands with center
frequencies between 100 and 3150Hz.

The measured Impact Sound Pressure (ISP) levels are then compared to a standard IMPACT
NOISE REFERENCE CONTOUR.

Through there was objection for the tapping machine as a noise source in establishing sound
insulation ratings of floors, no better method is available.

NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T

Page 31

What is CROSS TALK?

Noise between adjacent spaces served by common ducts is known as crosstalk.

To reduce crosstalk, main duct runs should be located above corridors, with individual branches
extending to each space.

Return air transfer ducts to plenum spaces above ceilings should have duct liner installed, and
there should be an elbow in the duct

Internally lined return air transfer duct above ceiling (with one elbow) to control crosstalk.
What is DUCT LAGGING?

Duct lagging is usually specified as part of a design or as a retrofit to solve an existing breakout
noise problem.

Duct lagging may include enclosing the duct in gypsum board or insulation wrapped in sheet
lead.

Duct lagging using a gypsum board enclosure (left) or lead-wrapped around insulation (right).

NOISE CONTROL AND SOUND ABSORBTION

SATHISH KUMAR T