CHEMICAL INDUSTRY
98
SA-587
(Identical with ASTM Specification A 587-93 except for the deletion of 1.5.)
1.
Scope
1.1 This specification covers electric-resistancewelded low-carbon steel pipe intended for use as process lines.
1.2 Pipe ordered under this specification shall be
suitable for severe forming operations involving flanging
in all sizes and bending to close radii up to and
including NPS 4.
1.3 This specification covers NPS 12 through 10,
plus additional sizes. The corresponding outside diameters and wall thicknesses for NPS 12 through 10 are
listed in Table 4, as are the dimensions for the additional sizes.
3.
1.5 DELETED
2.
Ordering Information
Referenced Documents
98
SA-587
4.
1998 SECTION II
6.
Mechanical Requirements
6.1 Tensile Properties:
6.1.1 The material shall conform to the requirements as to tensile properties prescribed in Table 2.
4.4 Heat Treatment Pipe furnished in the aswelded condition shall be normalized at a temperature
above the upper critical temperature. Cold-drawn pipe
shall be normalized after the final cold-draw pass.
Chemical Composition
where:
H p
t p
D p
e p
8.
7.
SA-587
9.
Number of Tests
7.3 Lengths:
10.
Retests
SA-587
11.
1998 SECTION II
Retreatment
12.
13.
Nondestructive Test
13.6.2.1 Dinges,
13.6.2.2 Straightener marks,
13.6.2.4 Scratches,
16.
14.
Product Marking
Inspection
15.
SA-587
Rejection
17.
15.1 Each length of pipe received from the manufacturer may be inspected by the purchaser and, if it does
not meet the requirements of this specification based
on the inspection and test method as outlined in the
specification, the length may be rejected and the manufacturer shall be notified. Disposition of rejected pipe
Packaging
98
SA-587
1998 SECTION II
TABLE 1
CHEMICAL COMPOSITION REQUIREMENTS
Element
Composition, %
Carbon, max
Manganese
Phosphorus, max
Sulfur, max
Aluminum
0.15
0.270.63
0.035
0.035
0.020.100
TABLE 2
TENSILE REQUIREMENTS
Tensile strength, min, psi (MPa)
Yield strength, min, psi (MPa)
Elongation in. 2 in. or 50 mm, min, %
48 000 (331)
30 000 (207)
40
TABLE 3
FLANGE REQUIREMENTS
Outside Diameter of Pipe, in.
Over
Over
Over
Over
Over
Width of Flange, % of OD
3 to 21 , incl
4
2
212 to 334, incl
334 to 412, incl
412 to 658, incl
658
15
1212
10
712
5
1074
SA-587
TABLE 4
TOLERANCE FOR OUTSIDE DIAMETER AND WALL THICKNESS
NPS
Designator
Wall Thickness
Outside
Diameter
Min
Nom
Max
Min
Nom
Max
0.129
0.125
0.135
0.135
0.157
0.157
0.167
0.175
0.175
0.191
0.262
0.295
0.378
0.438
0.520
0.140
0.140
0.147
0.147
0.171
0.171
0.182
0.190
0.190
0.208
0.286
0.322
0.412
0.478
0.567
0.151
0.151
0.159
0.159
0.185
0.185
0.197
0.205
0.205
0.225
0.310
0.349
0.446
0.518
0.614
Inches
1
2
3
4
1
114
112
2
3
4
6
8
10
0.8125 6 0.004
0.840 6 0.006
1.050 6 0.006
1.0625 6 0.006
1.3125 6 0.006
1.315 6 0.006
1.660 6 0.007
1.875 6 0.008
1.900 6 0.008
2.375 6 0.010
3.500 6 0.015
4.500 6 0.017
6.625 6 .030
8.625 6 .040
10.750 6 .050
0.095
0.095
0.099
0.099
0.116
0.116
0.121
0.127
0.127
0.135
0.189
0.207
0.245
0.282
0.319
0.103
0.103
0.108
0.108
0.126
0.126
0.132
0.138
0.158
0.147
0.206
0.226
0.267
0.308
0.348
0.111
0.111
0.117
0.117
0.136
0.136
0.143
0.149
0.149
0.159
0.223
0.245
0.289
0.334
0.377
Millimetres
1
2
3
4
1
114
112
2
3
4
6
8
10
20.64 6 0.10
21.30 6 0.15
26.70 6 0.15
26.99 6 0.15
33.34 6 0.15
33.40 6 0.15
42.16 6 0.18
47.63 6 0.20
48.30 6 0.020
60.33 6 0.25
88.90 6 0.38
114.30 6 0.43
168.28 6 0.76
219.08 6 1.02
273.05 6 1.27
2.41
2.41
2.51
2.51
2.95
2.95
3.07
3.22
3.22
3.43
4.80
5.26
6.22
7.16
8.10
2.62
2.62
2.74
2.74
3.20
3.20
3.35
3.51
3.51
3.73
5.23
5.74
9.32
7.82
8.84
2.82
2.82
2.97
2.97
3.45
3.45
3.63
3.78
3.78
4.04
5.66
6.22
7.34
8.48
9.58
3.28
3.28
3.43
3.43
3.99
3.99
4.24
4.45
4.45
4.85
6.66
7.49
9.60
11.13
13.21
3.56
3.56
3.73
3.73
4.34
4.34
4.62
4.83
4.83
5.28
7.26
8.18
10.47
12.14
14.40
TABLE 5
PERMISSIBLE VARIATIONS IN LENGTHA
Cut Length, in. (mm)
Outside Diameter, in.
Over
1
Under 2
2 and over
16
(3.2)
(4.8)
Under
0
0
A These permissible variations in length apply to pipe before bending. They apply to cut lengths up to and
including 24 ft (7.3 m). For lengths over 24 ft, an additional over-tolerance of 18 in. for each 10 ft (3.0
m) or fraction thereof shall be permissible, up to a maximum of 12 in. (12.7 mm).
1075
3.84
3.84
4.04
4.04
4.70
4.70
5.00
5.21
5.21
5.72
7.87
8.87
11.33
13.16
15.60
SA-587
1998 SECTION II
SUPPLEMENTARY REQUIREMENTS
One or more of the supplementary requirements described below may be included
in the purchasers order or contract. When so included, a supplementary requirement
shall have the same force as if it were in the body of the specification. Supplementary
requirements details not fully described shall be agreed upon between the purchaser
and the supplier, but shall not negate any of the requirements in the body of the
specification.
S1.
Hydrostatic Testing
S2.
Galvanizing
S2.1 Galvanizing shall be in accordance with Specification A 53, except that the rate of application shall
be 1.3 minimum to 1.7 maximum oz per f2.
S3.
Surface Coatings
1076