Sie sind auf Seite 1von 11

SITE

CUEVASLOTMMS
CP Tinga St: Baybreeze Executive
Village,Brgy San Miguel,Taguig City

SITE
PE
AR

CME
RF
TRM
DATE:

DE

SITE CODE/SITE NAME:

N0041
CUEVASLOTMMS
ADDRESS: CP Tinga St: Baybreeze Executive Village,
Brgy San Miguel,Taguig City

ENGINEER

REV.

NA

UL
LA

DATE

DE

AG

VE

VICINITY MAP

SAQ

SE

CA

M.L
Q

UE
ZO

NA

VE

AM
OR

LS
T:

SITE LOCATION MAP

DESCRIPTION

SHEET CONTENTS
SITE LOCATION MAP
VICINITY MAP

NO:
PRC NO.
TIN NO:
PLACE ISSUED:

PTR NO.:
DATE ISSUED:

SHEET NO.

1
10

CADD BY: Cky

SCALE: AS SHOWN DWG NO.: NCR-N0041-S01

EXISTING
MW

EXISTING
WIMAX- ANTENNA

EXISTING
HUAWEI LTE

9500

EXISTING
HUAWEI LTE

1714

EXISTING
WATER TANK

EXISTING
WIMAX- ANTENNA

9500

3589

EXISTING
GENSET

7786
600

A
EXISTING
HUAWEI LTE

1669

GEOGRAPHICAL
COORDINATESDATUM:

EXISTING
WIMAX- ANTENNA

DATUM:

EXISTING OUTDOR
EQUIPMENT

GUARD
HOUSE

WGS84

EXISTING ANTENNA
ANTENNA
EXISTING
ACPDB

AZIMUTH

HEIGHT (ACL)

DOWN TILT
ELEC.MECH

40.0m 3 LEGGED

S1 (WIMAX)

35.0M

LEGC

S2 (WIMAX

35.0M

LEG-A

S3 (WIMAX)

35.0M

LEG-B

S1 (HT LTE)

31.0M

LEG-C

S2 (HT LTE)

31.0M

LEG-A

S3 (HT LTE)

31.0M

LEG-B
LEG-A

ENTRANCE GATE

EXISTING TOWER HEIGHT :40.0m 3 LEGGED SST TOWER


3500

5850

ANTENNA CONFIGURATION
SCALE:

EXISTING SITE LAYOUT


SCALE:

BEFORE
SAQ

1:100

SITE CODE/SITE NAME:

CME

N0041
CUEVASLOTMMS

RF
TRM
DATE:

1:100

ADDRESS:

CP Tinga St: Baybreeze Executive Village,


Brgy,San Miguel,Taguig City.

ENGINEER

REV.

DATE

DESCRIPTION

SHEET CONTENTS

SHEET NO.

EXISTING SITE LAYOUT

2
PRC NO.:
TIN NO.:
PLACE ISSUED:

PTR NO.:
DATE ISSUED:

10
CADD BY: Cky

SCALE: AS SHOWN DWG NO.: NCR-N0041-S02a

SECTOR-C
PROPOSED
MW-2

ANT.HT=25.0m

SECTOR-A

1520

ANT.HT=25.0m

EXISTING
GENSET

C
A
PROPOSED LOCATION
FOR METRO TTA RRU

PROPOSED
MW-3

9500

PROPOSED
MW-1

9500

3589

EXISTING
GENSET

7980
795

1669

PROPOSED LOCATION
FOR ZTE EQUIPMENT

GEOGRAPHICAL
COORDINATESDATUM:

GUARD
HOUSE

DATUM:

WGS84

PROPOSED ANTENNA
EXISTING
ACPDB & MCB

ENTRANCE GATE

ANTENNA
AZIMUTH HEIGHT (ACL)

DOWN TILT
ELEC.MECH.

ANTENNA

ANTENNA
MODEL

SECTOR-A

RPX310B-B2
RVVPX310.11=132

25.0M

LEG-A

SECTOR-B

RPX310B-B2
RVVPX310.11=132

25.0M

LEG-B

SECTOR-C

RPX310B-B2
RVVPX310.11=132

25.0M

LEG-C

3 LEGGED TOWER

SECTOR-B
ANT.HT=25.0m

3500

AFTER

LEG-A

MW-2

LEG-B

MW-3

LEG-A

5850

PROPOSED TOWER HEIGHT : 40.0m 3 LEGGED TOWER

PROPOSED SITE LAYOUT


SCALE:

MW-1

1:100

ANTENNA CONFIGURATION
SCALE:

SAQ

SITE CODE/SITE NAME:

CME

N0041
CUEVASLOTMMS

RF
TRM
DATE:

ADDRESS:

CP Tinga St: Baybreeze Executive Village,


Brgy,San Miguel,Taguig City.

ENGINEER

REV.

DATE

DESCRIPTION

1:100

SHEET CONTENTS
PROPOSED SITE LAYOUT
ANTENNAE CONFIGURATION

PRC NO.:
TIN NO.:
PLACE ISSUED:

PTR NO.:
DATE ISSUED:

SHEET NO.

3
10

CADD BY: Cky

SCALE: AS SHOWN DWG NO.: NCR-N0041-S02b

TOP OF 40.0m 3 LEGGEND TOWER


PROPOSED
MW-2

PROPOSED
MW-2

PROPOSED
MW-1
PROPOSED
MW-1

PROPOSED
MW-3

PROPOSED
MW-3

PROPOSED LOCATION
FOR METRO TTA RRU

PROPOSED LOCATION
FOR METRO TTA RRU
OF PROPOSED OF ANTENNA

EXSITING
ACPDB
EXSITING
ACPDB

PROPOSED LOCATION
FOR ZTE EQUIPMENT

PROPOSED LOCATION
FOR ZTE EQUIPMENT

FRONT ELEVATION
SCALE:

SAQ

SITE CODE/SITE NAME:

CME

N0041
CUEVASLOTMMS

RF
TRM
DATE:

RIGHT SIDE ELEVATION


SCALE:

1:100

ADDRESS:

CP Tinga St: Baybreeze Executive Village,


Brgy,San Miguel,Taguig City.

ENGINEER

REV.

DATE

DESCRIPTION

1:100

SHEET CONTENTS

SHEET NO.

SITE ELEVATION

4
PRC NO.:
TIN NO.:
PLACE ISSUED:

PTR NO.:
DATE ISSUED:

10
CADD BY: Cky

SCALE: AS SHOWN DWG NO.: NCR-N0041-S04

SAQ
CME
RF

SITE CODE/SITE NAME:

N0041
CUEVASLOTMMS

TRM
DATE:

ADDRESS:

CP Tinga St: Baybreeze Executive Village,


Brgy San Miguel,Taguig City

CC1

EXT

CC1

ETH0

CC2

EXT

CC2

ETH0

ENGINEER

REV. DATE

DESCRIPTION

SHEET CONTENTS

SHEET NO.

RF DIAGRAM

5
PRC NO.:
TIN NO.:
PLACE ISSUED:

PTR NO.:

10

DATE ISSUED:

CADD BY: cKy

SCALE:AS SHOWN DWG NO. NCR-N0041-A02

PROPOSED
MW-3

EXISTING
WIMAX- ANTENNA

EXISTING
WIMAX- ANTENNA

EXISTING
HUAWEI LTE

PROPOSED
MW-2
EXISTING
WIMAX- ANTENNA

PROPOSED
MW-3

SECTOR-A
ANT.HT=25.0m

EXISTING
HUAWEI LTE

PROPOSED LOCATION
FOR METRO TTA RRU

EXISTING
HUAWEI LTE

SECTOR-C
ANT.HT=25.0m

SECTOR-B
ANT.HT=25.0m

ISOMETRIC VIEW

BEFORE

SCALE:

SAQ

SITE CODE/SITE NAME:

CME

N0041
CUEVASLOTMMS

RF
TRM
DATE:

AFTER

1:30

ADDRESS:

CP Tinga St: Baybreeze Executive Village,


Brgy,San Miguel,Taguig City.

ENGINEER

REV.

ISOMETRIC VIEW
SCALE:

DATE

DESCRIPTION

1:30

SHEET CONTENTS

SHEET NO.

ANTENNA ISOMETRIC VIEW

6
PRC NO.:
TIN NO.:
PLACE ISSUED:

PTR NO.:
DATE ISSUED:

10
CADD BY: Cky

SCALE: AS SHOWN DWG NO.: NCR-N0041-S02a

EXISTING OUTDOOR
EQUIPMENT SHELTER

EXISTING
OUTDOOR
EQUIPMENT

EXISTING
WI-TRIBE
CABINET

150 75

370

75

600

200

600

9175

150

162
3300

EXISTING CABLE
LADDER

BEFORE

EXISTING EQUIPMENT LAYOUT


SCALE:

SAQ

SITE CODE/SITE NAME:

CME

N0041
CUEVASLOTMMS

RF
TRM
DATE:

ADDRESS:

CP Tinga St: Baybreeze Executive Village,


Brgy,San Miguel,Taguig City.

1:100

ENGINEER

REV.

DATE

DESCRIPTION

SHEET CONTENTS

SHEET NO.

EXISTING EQUIPMENT LAYOUT

7
PRC NO.:
TIN NO.:
PLACE ISSUED:

PTR NO.:
DATE ISSUED:

10
CADD BY: Cky

SCALE: AS SHOWN DWG NO.: NCR-N0041-E01a

EXISTING OUTDOOR
EQUIPMENT SHELTER

PROPOSED LOCATION
FOR ZTE EQUIPMENT

520

150

850

1500
3000

EXISTING CABLE
LADDER

AFTER

PROPOSED EQUIPMENT LAYOUT


SCALE:

SAQ

SITE CODE/SITE NAME:

CME

N0041
CUEVASLOTMMS

RF
TRM
DATE:

ADDRESS:

CP Tinga St: Baybreeze Executive Village,


Brgy,San Miguel,Taguig City.

1:100

ENGINEER

REV.

DATE

DESCRIPTION

SHEET CONTENTS

SHEET NO.

PROPOSED EQUIPMENT LAYOUT

8
PRC NO.:
TIN NO.:
PLACE ISSUED:

PTR NO.:
DATE ISSUED:

10
CADD BY: Cky

SCALE: AS SHOWN DWG NO.: NCR-N0041-E01b

SAQ
CME
RF

SITE CODE/SITE NAME:

N0041
CUEVASLOTMMS

TRM
DATE:

ADDRESS:

CP Tinga St: Baybreeze Executive Village,


Brgy San Miguel,Taguig City

ENGINEER

REV. DATE

DESCRIPTION

SHEET CONTENTS

SHEET NO.

RF DIAGRAM

9
PRC NO.:
TIN NO.:
PLACE ISSUED:

PTR NO.:

10

DATE ISSUED:

CADD BY: cKy

SCALE:AS SHOWN DWG NO.

SCHEDULE OF LOADS ( 60AMP MAIN )


PANEL: MCB
ENCLOSURE: IP 55 W/ GROUNDING BAR; BOTTOM FEED
POWER SOURCE: 230V, 1-PHASE, 60HZ
CKT.
NO. VOLTS

INCOMING FROM MERALCO


CORPORATION

LOAD DESCRIPTION

CKT. VA

AMP

BRANCH CIRCUIT BREAKERS


AT

KAIC

POLE

TYPE

230

RECTIFIER

4000

17.39

40

10KA

2P

100AF,QOB

WIRE

230

SPARE

1000

4.35

20

10KA

2P

100AF,QOB

230

SPARE

230

SPARE

TOTAL

5,000

21.74

GROUND

CONDUIT

COMPUTATION:

MCB
125 AT

AMP = 21.74
DEMAND FACTOR (%) = 100
I TOTAL AMP = 21.74

FEEDER:
GROUNDING BUS.

125AT,2P

PROTECTION:
60 AT, 100 AF, 2P, 230 V, 25 KAIC (E2D)

TWIST LOCK
FOR MOBILE GENSET

RECTIFIER-1

TOWER LIGHT

SPARE

1
3
5

63AT,2P

32AT,2P

20AT,2P

32AT,2P

20AT,2P

20AT,2P

PERIMETER LIGHT

LIGHT

HUAWEI LTE
PROPOSED BELLTEL
MAIN PANEL BOARD
IP 55 Enclosure

GROUNDING BUS.

EXISTING
SINGLE LINE DIAGRAM
SCALE :

ACPDB,
60AT,
2P

NTS

TVSS
120 Ka

GENERAL NOTES:
40AT,2P

1. ALL ELECTRICAL INSTALLATION WORKS HEREIN SHALL BE DONE IN


ACCORDANCE WITH BELLTEL SPECIFICATIONS, THE LATEST EDITION OF THE
PHILIPPINE ELECTRICAL CODE, THE RULES AND REGULATION OF THE LOCAL
MUNICIPALITY AND POWER UTILITY COMPANY.
2. WIRING METHOD:
A. INTERMEDIATE METAL CONDUIT (IMC) FOR SERVICE ENTRANCE AND ALL EXPOSED
PORTIONS
B. UNDERGROUND CONDUITS SHALL BE PVC, ENCASED IN CONCRETE.
C. GROUNDING WIRES SHALL BE INSULATED.
3. ALL NON-CURRENT CARRYING ELECTRICAL EQUIPMENT PARTS SHALL BE PROPERLY
GROUNDED.

SPARE

SPARE

SPARE

PROPOSED TERMINAL 4 FOR


ZTE EQUIPMENT TAPPING
POINT PROVIDE 40Amps TO
CHANGE EXISTING CIRCUIT
BREAKER.

INDICATED.
5. ALL WIRES SIZE SHALL BE A BRAND APPROVED BY BELLTEL.
6. WIRING DEVICES SHALL BE A BRAND APPROVED BY BELLTEL.
7. ALL CIRCUIT BREAKERS SHALL BE SQUARE D BRAND, BOLT ON TYPE IN IP 55
ENCLOSURE FOR OUTDOOR LOCATIONS, USING BELLTEL TYPE APPROVED
ENCLOSURE.
8. MAIN CIRCUIT BREAKERS SHALL BE INDUSTRIAL TYPE, 25 KAIC, WHILE BRANCH CIRCUIT
BREAKERS SHALL BE COMMERCIAL TYOE, 10 KAIC.
9. INSULATION TEST SHALL BE DONE BEFORE THE SITE IS ENERGIZED AND WITNESSED BY
BELLTEL. RESISTANCE SHALL BE GREATER THAN FIFTY(50) MEGA OHMS.
10. ALL EQUIPMENT AND MATERIALS SHALL BE BRAND NEW AND SUITED TO THE REQUIRED
USE.
11. PULL BOXES OR JUNCTION BOXES SHALL BE PROVIDED, EVEN IF NOT INDICATED IN THE
PLANS.
12. ALL ELECTRICAL WORKS SHALL BE DONE UNDER THE DIRECT SUPERVISION OF A DULY
LICENSED AND REGISTERED ELECTRICAL ENGINEER.

SAQ
CME
RF
TRM
DATE:

20AT,2P

RECTIFIER

LEGEND:

TO GROUNDING LOOP

PROPOSED BELLTEL
SINGLE LINE DIAGRAM
SCALE :

KILOWATT HOUR METER

ECB

ENCLOSED CIRCUIT BREAKER

MTS

MANUAL TRANSFER SWITCH

ACPDB

AC PANEL DISTRIBUTION BOARD

TVSS

NTS

GROUND

SERVICE ENTRANCE

SITE CODE/SITE NAME:

N0041
CUEVASLOTMMS
ADDRESS: CP Tinga St:Baybreeze Executive Village
Brgy.San Miguel,Taguig City.

ENGINEER

REV.

DATE

DESCRIPTION

SHEET CONTENTS

SHEET NO.

SINGLE LINE DIAGRAM FOR COLOCATED WTI SITES

10
PRC NO.:
TIN NO.:
PLACE ISSUED:

PTR NO.:
DATE ISSUED:

10
CADD BY: Cky

SCALE: AS SHOWN DWG NO.: NCR-N0041-E03

Das könnte Ihnen auch gefallen