Sie sind auf Seite 1von 2

All Galesburg Refrigeration Produced Platform.

Models:
,QFOXGHVDOO*DOHVEXUJUHIULJHUDWRUPRGHOVPDQXIDFWXUHGSULRUWR0D\RIZLWK$'&GHIURVW
F\FOH GRHVQRWLQFOXGHWKH-HQQ$LUŠ/X[XU\Œ6HULHVUHIULJHUDWRUV 
Adaptive Defrost Control
7KH DGDSWLYH GHIURVW FRQWURO DVVHPEO\ LV D PLFURSURFHVVRU FRQWUROOHG GHIURVW WLPHU 7KLV QHZ
control allows defrost to occur only when needed, compared to mechanical timers which defrost
DWDSUHVHWLQWHUYDOZKHWKHULWLVQHFHVVDU\RUQRW7KHQHZFRQWUROZLOOFRQWLQXDOO\DGMXVWGHIURVW
LQWHUYDOVEDVHGRQWKHDPRXQWRIWLPHWKHGHIURVWKHDWHULVHQHUJL]HG7KLVDOORZVWKHGHIURVW
LQWHUYDOEDVHGRQXVHWKXVVDYLQJHQHUJ\
Checking the Adaptive Defrost Control
 'LVFRQQHFWWKHXQLWIURPWKHSRZHUVRXUFH
 2SHQWKHIUHVKIRRGDQGUHPRYHDQ\LWHPVRQWKHWRSVKHOI
 5HPRYHWKHOLJKWVKLHOGDQGWKHWHPSHUDWXUHFRQWUROKRXVLQJ
 &RQQHFWWKHUHIULJHUDWRUWRDZDWWPHWHU
 0DNHVXUHFRPSUHVVRULVUXQQLQJ FROGFRQWUROFORVHG 
 8VLQJ DQ LQVXODWHG QXPEHU  MXPSHU ZLUH VKRUW EHWZHHQ / DQG 7HVW WKLV ZLOO SXW WKH
UHIULJHUDWRULQWRDGHIURVWIRUDSSUR[LPDWHO\PLQXWHV
 7KHZDWWPHWHUVKRXOGUHDGEHWZHHQWRZDWWVGHSHQGLQJRQWKHPRGHO

NOTE,IWKHWHPSHUDWXUHFRQWUROLVRSHQ XQLWQRWUXQQLQJDQG\RXMXPSHU/DQG7HVW WKHXQLW


ZLOOF\FOHWKURXJKWKHWHVWPRGHLQWZRVHFRQGVDQGWKHUHZLOOEHQRZDWWGUDZ
Action
7KHLVVXHLVWKDWVRPH$'&ERDUGVKDYHEHHQVKLSSHGLQWKH$'&ERDUG
ER['RQRWUHRUGHUWKHERDUGWKHERDUGZLOOIXQFWLRQWKHVDPHLQSODFHRIWKH
EXWPXVWXVHWKHIRUFHGGHIURVWPHWKRGIRUWKH VKRZQLQ)LJXUH

61005988

Heater

Comp

L2

D Stat

Test

L1

Figure 1
Galesburg Produced Platform produced
before May 2003

66
Buy parts at parts.fixitnow.com
Galesburg Produced Platform Produced Before May 2003 (Figure 1)
To initiate Forced Defrost Cycle:
-XPS/WR7HVW
7R7HUPLQDWH)RUFHG'HIURVW&\FOHGLVFRQQHFWSRZHUIRU¿YHVHFRQGV

12002104
Heater

Comp

L2

D Stat

Door

L1

Figure 2

Amana Produce Platform after June 2003


Galesburg Produced Platform after April 2003

Amana Product Platform After June 2003


Galesburg Product Platform After April 2003 (Figure 2)

To initiate Forced Defrost Cycle:


&\FOHFROGFRQWURORQDQGRIIWKUHHWLPHVLQVL[VHFRQGV7KHFROGFRQWUROQHHGVWREHOHIWLQWKH
FORVHG FDOOIRUFRROLQJ SRVLWLRQIRUWKHGHIURVWV\VWHPWRHQHUJL]HRQDOOSODWIRUPV,WLVQRWHQRXJK
WRF\FOHWKHFROGFRQWURONQREWKHFRQWDFWVPXVWDFWXDOO\RSHQDQGFORVH RSHQGRRUVIRUDSHULRG
RIWLPHLIQHFHVVDU\WRIRUFHWKHFRQWUROWRFDOOIRUFRROLQJ ,QPRVWFDVHV\RXFDQKHDUWKHFRQ
WDFWVRSHQDQGFORVHLIWKH\DUHGRLQJVR
To Terminate Forced Defrost Cycle:
'LVFRQQHFWSRZHUIRU¿YHVHFRQGV

67
Buy parts at parts.fixitnow.com

Das könnte Ihnen auch gefallen