Beruflich Dokumente
Kultur Dokumente
3-STALL
A2.1 - Foundation Plan
A2.2 - Lower Level Framing Plan
A2.3 - Main Level Framing Plan
A2.4 - Upper Level Framing Plan
A3.1 - Wall Section
A3.2 - Building Section
A4.1 - Lower & Main Level HVAC Layout
A4.2 - Upper Level HVAC Layout
A5.1 - Floor Joist Layouts
A5.2
DESIGN REVIEW
CONSTRUCTION
PERMIT/PRICING
- Roof Truss Layout
D1.1
DESCRIPTION
- Lower & Main Level Design Plan
DOCUMENT
DOCUMENT
D1.2 - Upper Level Design Plan
E1.1 - Lower & Main Level Electrical Plan
ISSUE
E1.2 - Upper Level Electrical Plan
05-19-08
03-18-08
12-14-07
DATE
GENERAL PROJECT NOTES
NO.
6
3
5
2
1
1. Building design and construction are complex
endeavors. Although the designer and
Castleton - Timberframe
from the responsibility of consequences due to
such changes.
PLAN LEGEND
- Indicates floor elevation change
A
A2.1
- Indicates section / detail indicator
100'-0" - Indicates relative elevation reference CONCRETE FOOTING / ROUGH-IN NOTES MECHANICAL SYSTEMS ELECTRICAL NOTES INSULATION NOTES
FLATWORK NOTES (If applicable)
1. 2x4 walls to receive minimum R-13 insulation.
FRAMING PLUMBING 1. See page E1.1 & E1.2 for electrical layout
- Indicates non-bearing wall 1. For details see page A2.2, A2.3, A2.4, A3.1 1. Fixture selections by contractor in coordination including general fixture locations and switching. 2x6 walls to receive minimum R-21 insulation.
FOOTINGS / FLATWORK
& A3.2 with owner. Coordinate requirements of 2. Outlets shown on plan are to be verified by 2. All foam insulation to consist of closed cell
1. For typical wall and footing details see page
2. Provide all connectors and support hangers to selected fixtures with subcontractors. Provide electrical contractor to meet or exceed all product.
- Indicates bearing wall A2.1, A3.1 & A3.2
comply with local building codes. "low flow" fixtures meeting state and local code requirements. 3. Joist rim board to receive insulation. Take
2. The general contractor and concrete
3. Floor system layout to be 11 7/8" I-Joist. regulations. 3. Stair lighting and switching to be provided to special care to seal around all penetrations.
subcontractors shall field verify rebar
INTERIOR DOOR DETAIL specifications, foundation wall and footing Minumum deflection L/480. 2. Take care to locate all waste lines to minimize meet code requirements. 4. Attic to have minimum R-38 insulation.
Interior door style to be selected by owner 4. Truss system layout and loading to be noise. Insulate where possible. 4. Provide all smoke detectors, heat sensors and 5. Fill around all exterior doors and windows with
elevations based on field conditions.
confirmed by local supplier @ maximum local 3. Take care to locate plumbing vents away from carbon monoxide detectors as required by non expanding spray foam.
3. The general contractor and concrete
code requirements. valleys, vertical walls, etc. Locate on sunny code. 6. Seal all penetrations between floors per fire
Door width and height subcontractors shall field verify daylight,
5. All dimensions are frame to frame including roof areas away from entry elevation sight 5. See legend on electrical pages for electrical code requirements.
walkout and frost wall locations and sizes.
7/16" sheathing at exterior walls. lines. symbols. 7. Provide acoustic batt insulation between bath,
4. Assumed design soil bearing pressure =
6. Align studs with joists, rafters and truss 4. Water heater to be minimum 50 gallon. 6. All recessed cans to be "I.C." units in bedrooms and laundry rooms.
2'-6" 2,000 psf.
100
1. There shall be a minimum 5" granular material all interior walls, not to roof trusses to avoid line for dishwasher
under all slabs on grade. adhesive between sill plate and sub floor. HVAC
nail pops due to predicted truss movement. 5. Dryer - Gas/Electric
Bottom of Header 2. Concrete slabs on grade shall be minimum 4" 13. Provide sill seal between sill plate and 1. Provide combustion air supply for furnace and
5. All floors to receive adequate protection during 6. Furnace - Gas
thick. concrete. hot water heater as required by code and local
hang and finish of drywall. 7. Hot Water Heater - Gas
MASTER
regulations.
1234
3. All slabs on grade shall have a control or 6. Drywall contractor to be responsible to 8. Cabinetry supplier to field verify all dimensions
construction joint at a maximum spacing in feet WINDOWS AND DOORS 2. Floor drain to be provided in all mechanical
remove all drywall scrap and waste from site. prior to ordering and fabricating cabinetry.
of three times the slab thickness in inches 1. Windows and patio doors specified on plan are areas. Location of drains not specified on plan
Reference number to Andersen 200 series windows unless noted 7. All drywall to be primed prior to installation of
each way. Maintain aspect ratio not to shall be decided by the general contractor in
window manufacturer interior trim.
PAGE
exceed 1.5. (To be cut within 24 hours of otherwise. coordination with sub contractors.
2. See pages A2.2, A2.3 & A2.4 for individual 8. Test moisture content to confirm below
pouring concrete.) 3. 5 Ton forced air heating and cooling system.
model numbers and rough opening sizes. maximum content required by drywall
4. All slabs in heated areas to receive ridgid 4. Furnace efficiency to be 90% or greater.
3. All windows and doors to have a maximum air manufacturer. (Provide verification.)
SITE WORK & GRADING NOTES insulation below but do not separate slab from
infiltration rating of 0.3 cfm.
5. Air conditioner to have SEER rating of 13 or FLOORING LEGEND
footings to act as vapor barrier. greater. (Optional)
4. All windows to have Low E argon filled glass. 6. Programmable thermostat to be provided.
TREE REMOVAL
Verify with manufacturer. 7. Heat recovery ventilator to be provided. - Carpet flooring
1. Excavator shall use extreme caution when
excavating around trees to be preserved. (Optional)
Hand excavate around exposed roots. 8. Provide vent fan with back draft damper in all
bathrooms. - Tile or vinyl flooring
EXCAVATION & BACKFILL 9. Any and all duct work in attic to be insulated.
1. All excavation and backfill shall be conducted in 10. All duct work to be sealed with mastic or tape.
11. Zone upper level seperate. (Optional) - Wood
strict accordance with the soils report.
A0.0
2. Provide foundation drain per soils report.
3. Maintain positive drainage away from
- Decking
foundation @ minimum 5% grade
NOT TO
SCALE
WILLISTON, NORTH DAKOTA
12
CASTLETON
TIMBER BRACKET CHIMNEY
TIMBERFRAME
3-STALL
CONTINUOUS RIDGE VENT
10/12 ROOF PITCH
ROOFING:
30 YEAR LANDMARK 10/12 ROOF PITCH TOP OF U.L.
118'-3"
BY CERTAINTEED WALLS
TOP OF U.L. DOORS R.O.
6" BAND BOARD
TOP OF U.L. WINDOWS R.O.
10/12 ROOF PITCH
8'-11/8"
6'-11"
DESIGN REVIEW
CONSTRUCTION
PERMIT/PRICING
DESCRIPTION
DOCUMENT
DOCUMENT
SOFFIT: VINYL VENTED TOP OF U.L. 7/8"
110'-1
FASCIA: 6" ALUM. WRAP SUB-FLOOR
FRIEZE BOARD: 6" REVEAL TOP OF M.L. 1/8"
109'-1
ISSUE
ALUM. WRAP WALLS
1'-0 3/4"
1'-0"
1'-0" 1'-0"
TOP OF M.L. DOORS R.O.
05-19-08
03-18-08
5" FIBER CEMENT TOP OF M.L. WINDOWS R.O.
12-14-07
DATE
CORNER
NO.
6
3
5
2
9'-1 1/8"
1
6'-11"
6" REVEAL CLAPBOARD
TOP OF CAP
2'-3"
100'-0"
1'-2 1/4"
TOP OF L.L. DOORS R.O.
TOP OF L.L. WINDOWS R.O.
8' x 8' GARAGE DOOR 16' x 8' GARAGE DOOR
WINDOW & DOOR TRIM:
4'-0"
STEEL STEEL W/ 6 WINDOW COLUMNS: ALUMINUM FRAME SCREEN
MANUFACTURER T.B.D. MANUFACTURER T.B.D. 3 - 8" SQUARE CEDAR ON 5" HEAD PIECE @ PORCH
24" SQUARE CULTURED STONE 3 1/2 " SIDES AND APRON
BASE W/ CAP COLUMNS:
12" SQUARE CEDAR ON TOP OF
CULTURED STONE
6'-11"
7'-9"
5/4" DECKING MATERIAL W/ 6" CAP & 8" BASE FOOTING
W/ CULTURED CAP
OVER 2x10 TRT. DECK JOISTS
TOP OF CONC
91'-0 3/4"
SLAB FLOOR
ENTRY ELEVATION
TOP OF
CHIMNEY
12
*OPTIONAL 10
METAL SADDLE &
FLASHING AS
REQUIRED @ CHIMNEY
8'-1 1/8"
6'-11"
TOP OF U.L. 7/8 "
110'-1
SUB-FLOOR
TOP OF M.L. 1/8"
109'-1
WALLS
1'-0 3/4"
1'-0"
1'-0" 1'-0"
ELEVATIONS
1'-0"
TOP OF M.L. DOORS R.O.
TOP OF M.L. WINDOWS R.O.
10'-10 1/2"
9'-1 1/8"
6'-11"
ENTRY &
5" FIBER CEMENT
CORNER
REAR
TOP OF M.L. SUB-FLOOR TOP OF M.L. SUB-FLOOR
100'-0"
1'-2 1/4"
TOP OF L.L. DOORS R.O.
TOP OF L.L. WINDOWS R.O.
CULTURED STONE WINDOW & DOOR TRIM:
4'-0"
4'-0"
ALUMINUM FRAME SCREEN
W/ CULTURED CAP 5" HEAD PIECE
@ PORCH
3 1/2 " SIDES AND APRON
COLUMNS: 6" BAND BOARD
TOP OF FOOTING 12" SQUARE CEDAR ON TOP OF FOOTING
6'-11"
7'-9"
W/ 6" CAP & 8" BASE EGRESS WINDOWS BELOW GRADE
TOP OF CO NC. SLAB
TO WINDOW
TOP OF CONC
91'-0 3/4"
SLAB FLOOR
A1.1
1/4" = 1'-0"
REAR ELEVATION
WILLISTON, NORTH DAKOTA
LOT 2 CREEKSIDE RIDGE
CASTLETON
TIMBERFRAME
CONSTRUCTION
PERMIT/PRICING
DESCRIPTION
DOCUMENT
DOCUMENT
ISSUE
7'-2" CONTINUOUS RIDGE VENT CONTINUOUS RIDGE VENT 7'-2"
05-19-08
03-18-08
12 30 YEAR LANDMARK 30 YEAR LANDMARK
12-14-07
DATE
TOP OF
BY CERTAINTEED BY CERTAINTEED
10 CHIMNEY
12 12
NO.
6
3
5
2
1
10 10
8'-11/8"
10
8'-11/8"
6'-11"
6'-11"
12
6'-6"
6" BAND BOARD CEDAR TIMBER
BEAMS
10
SOFFIT: WOOD SOFFIT: WOOD
2'-6"
FASCIA: 6" ALUM. WRAP TOP OF U.L. FASCIA: 6" ALUM. WRAP TOP OF U.L.
7/8" 7/8"
FRIEZE BOARD: 6" REVEAL 110'-1 FRIEZE BOARD: 6" REVEAL SUB-FLOOR 110'-1
SUB-FLOOR
ALUM. WRAP TOP PLATE OF M.L. WALL TOP OF M.L. TOP PLATE OF M.L. WALL ALUM. WRAP TOP OF M.L.
109'-1 1/8" 109'-1 1/8"
WALLS WALLS
1'-0 3/4"
1'-0 3/4"
1'-0"
1'-0" 1'-0" 1'-0" 1'-0" 1'-0"
6" REVEAL CLAPBOARD TOP OF M.L. DOORS R.O. COLUMNS: 6" BAND BOARD TOP OF M.L. DOORS R.O.
FIBER CEMENT SIDING TOP OF M.L. WINDOWS R.O. 3 - 8" SQUARE CEDAR ON TOP OF M.L. WINDOWS R.O.
24" SQUARE CULTURED STONE
BASE W/ CAP
COLUMNS: 6" REVEAL CLAPBOARD
3 - 8" SQUARE CEDAR ON FIBER CEMENT SIDING
5" FIBER CEMENT 24" SQUARE CULTURED STONE
9'-1 1/8"
9'-1 1/8"
CORNER BASE W/ CAP 5" FIBER CEMENT
6'-11"
6'-11"
CORNER
2'-3"
100'-0" 100'-0"
1'-2 1/4"
1'-2 1/4"
TOP OF L.L. DOORS R.O. TOP OF L.L. DOORS R.O.
TOP OF L.L. WINDOWS R.O. TOP OF L.L. WINDOWS R.O.
WINDOW & DOOR TRIM: WINDOW & DOOR TRIM:
4'-0"
4'-0"
5" HEAD PIECE SLOPE CONC. PATIO 5" HEAD PIECE
3 1/2 " SIDES AND APRON 5% FOR DRAINAGE 3 1/2 " SIDES AND APRON
ALUMINUM FRAME SCREEN
TOP OF FOOTING @ PORCH CULTURED STONE
6'-11"
6'-11"
7'-9"
7'-9"
W/ CULTURED CAP
COLUMNS:
12" SQUARE CEDAR ON
W/ 6" CAP & 8" BASE
ELEVATIONS
LEFT &
RIGHT
A1.2
1/4" = 1'-0"
WILLISTON, NORTH DAKOTA
LOT 2 CREEKSIDE RIDGE
CASTLETON
TIMBERFRAME
CONSTRUCTION
PERMIT/PRICING
DESCRIPTION
DOCUMENT
DOCUMENT
ISSUE
05-19-08
03-18-08
12-14-07
DATE
85'-0"
36'-0" 49'-0"
NO.
6
3
5
2
1
11'-8" 6'-6" 15'-0" 3'-6" 7'-6" 3'-6" 1'-4"
VERIFY OPENING SIZE
8"
8"
CONC. WALL
T.O.F. = 94'-9 3/4 "
2'-0"
7'- 4 1/2"
FROSTW ALL
6" CONC
8' POURED 16" x 8" CONC. FOOTING
FOR 2 x 6 BEARING WALL
CONC. WALLS CONC. WALL
12'-5"
T.O.F. = 90'-9 3/4"
13'-1 1/4"
16"x8" CONC. FTG.
1'-4"
T.O.W. = 98'-9 3/4"
15'-0"
4" CONCRETE SLAB FLOOR
@ 3" ABOVE FOOTINGS
17'-0 1/4"
8" CONC WALL
16"x8" CONC. FTG.
6" CONC
FROSTWALL
16"x8" CONC. FTG.
26'-0"
22'-0"
7'- 71/2"
T.O.F. = 94'-9 3/4 " 18"" x 18"" x 8" THICK @
T.O.W. = 98'-9 3/4 " C/L OF MIN. FROST DEPTH
BEAM POCKET
C/L OF
1'-4"
W.H. FOOTING
FLOOR
8" DRAIN 17'-5 1/2" 7'-0" 2'-0" 5'-6 1/2" 15'-8" 8"
B B
A3.2 8'-3" C/L OF A3.2
BEAM POCKET
FROSTWALL
16"x8" CONC. FTG.
6" CONC
10'-11"
11'-6 3/4"
16" x 8" CONC. FOOTING
1'-4"
10'-0"
FOR 2 x 6 BEARING WALL
6" CO NC 17'-11 1/4" 11'-5" 18'-3 3/4"
FROSTWALL
16"x8" CONC. FTG.
CONC. WALL
9'-5"
T.O.F. = 94'-93/4 "
3'-91/2"
C.L. OF 2 x 4 WALL
7'-7 3/4"
C.L. OF 2 x 4 WALL
T.O.W. = 98'-93/4"
7'- 0"
CONC. WALL
4'-1 1/2"
2'-9"
2'-31/2"
1'-0"
C/L OF
2'-0"
FOOTING
CONC. WALL
8"
8"
2'-0"
DECK FOOTINGS
A T.O.F. = 90'-9 3/4"
FOOTING
C/L OF T.O.W. = 98'-9 3/4"
26" x 26" x 8" THICK @ A3.1
C/L OF
FOOTING
MIN. FROST DEPTH
FOOTING
FOOTING
C/L OF
C/L OF
1'-10" 8'-4" 1'-10" 2'-3 1/2" 16'-4" 5'-4 1/2" 1'-0" 9'-7 1/2" 38'-4 1/2"
FOUNDATION
*NOTE: FIXTURE DIMENSIONS ITALICIZED
FOUNDATION
PLAN
A2.1
1/4" = 1'-0"
WILLISTON, NORTH DAKOTA
LOT 2 CREEKSIDE RIDGE
CASTLETON
TIMBERFRAME
CONSTRUCTION
PERMIT/PRICING
DESCRIPTION
DOCUMENT
DOCUMENT
ISSUE
05-19-08
03-18-08
12-14-07
DATE
49'-0"
NO.
6
3
5
2
1
10"
HEADER @ 83" AFF HEADER @ 83" AFF HEADER @ 83" AFF
10"
3'-0"
SUMP
CROCK GUEST 2'-4"
103
4'- 31/2"
BEDROOM CL. 6'-8"
8' CEILING
8" 9'-5 1/2" 31/2" 12'-0" 2'-4 1/2" 31/2" 3'-3" 31/2" 3'-3" 51/2" 15'-10" 10"
2'-7 1/2"
GAMES
4'- 11/2"
2'-0"
6'-8"
RISERS
117/8" I- JOISTS
UPSET LVL BEAM 16/0 x 17/0
SIZE T.B.D.
106
CL.
4'- 31/2"
2'-4"
102
UNEXCAVATED
8'-6"
6'-8"
DROPPED LVL BEAM 101
SIZE T.B.D.
2'-8"
6'-8"
8' CEILING
7' CEILING
CLG. 12"
HEADER
5 1/2"
DROP
6" 2'-10" 3'-0" 6" 2'-2" 10 1/2" 3'-3" 51/2"
W.H. 2'-8"
100
FURNACE
3'-5 1/2"
FLOO R
DRAIN
6'-8"31/2" DROPPED LVL BEAM
6'-0 1/2" 2'-8" 4'-10 1/2"
B SIZE T.B.D. B
A3.2 HEADER A3.2
5 1/2"
60" x 32"
117/8" I- JOISTS
11 7/8" I- JOISTS
8' CEILING
GAMES
CONC. FLOOR
BATH 7' CEILING
7'-5"
8' CEILING 16/0 x 7/0
6'-7"
2'-4"
104
6'-8"
17'-91/2" 31/2" 5'-0" 5 1/2" 5'-8" 31/2" 2'-2 1/2"
1'-6"
8"
A
A3.1
LINE OF PORCH ABOVE
LOWER LEVEL
892 sq ft
FRAMING
PLAN A2.2
1/4" = 1'-0"
WILLISTON, NORTH DAKOTA
LOT 2 CREEKSIDE RIDGE
CASTLETON
TIMBERFRAME
CONSTRUCTION
PERMIT/PRICING
DESCRIPTION
DOCUMENT
DOCUMENT
ISSUE
05-19-08
03-18-08
12-14-07
DATE
97'-0"
6'- 0" 16'-5" 13'-7" 7'- 8" 5'-9 1/2" 9'-0" 6'-1 1/2" 6'-4" 11'-0" 3'-1" 11'-6" 6"
NO.
6
3
5
2
1
6"
HEADER @ 83" AFF HEADER @ 83" AFF HEADER @ 83" AFF M.L. SUB FLOOR HEADER @ 83" AFF HEADER @ 83" AFF
244DH2850 244DH2850
2'-0"
6"
6"
R.O. 2'-8" x 5'-0" R.O. 2'-8" x 5'-0"
2'-0"
2'-2"
*OPTIONAL
3'-4"
HEADER @ 83" AFF OF HOUSE HEADER @ 83" AFF OF HOUSE DIRECT VENT
42" X 72" GAS FIREPLACE
3'-6"
TUB 6000G - 42"
TILE
6'-6"
BY HEAT-N-GLO
1'- 101/2"
SHOWER VERIFY FRAMING
SIZE PER MANUF.
SPECIFICATIONS
6" 4'-2" 6'- 0" 5 1/2" 13'-8" 31/2" 3'-3" 31/2" 3'-3" 31/2" 5'-6" 1'-0" 3'- 6" 1'-0" 5'-4" 6"
3 - 244FX3016 - TRANSOM
OWNER'S 2'-6"
204
OWNER'S
4'-7 1/2"
OPEN RAIL
BATH 6'-8"
13'-0"
13'-21/2"
4'-4"
5'-3"
RETREAT
10'-0"
8'-10 1/2"
9' CEILING
3 - 244DH3050
200 13/6 x 13/6
GREAT
HEADER @ 83" AFF OF HOUSE
C/L OF
2'-0"
6'-8"
2'-2" 9'-4" 2'-2"
DN 14
COL.
ROOM
6"
RISERS
6'-6"
COLUMN
UP 16
RISERS
9' CEILING
31/2"
C/L OF
16/6 x 14/6
OWNER'S
4'-0 1/2"
GARAGE 9' CEILING PORCH BEAM
SCREEN
R.O. 5'-4" x 5'-0"
2 - 244DH2850
5'-4 1/4"
20'-0"
DOOR
2'-4"
203
SLO PE FLOOR
CLG. 12"
9' CEILING 207
2'-2"
DROP
TO DRIVE 6'-8"
26'-0"
26'-0"
6" 3'-0" 31/2" 3'-5 7/8" 3'-4 5/8" 5 1/2"
31/2"
6'-8"
2'-8"
5 1/2"
C/L OF
COLUMN
6"
HEADER UPSET LVL BEAM
UTILITY DW. ARCH SIZE T.B.D.
3'- 31/2"
GALLERY
3'-0"
201 9' CEILING @ 7'-0" ARCH
6'-0"
B TO 8'-0" B
16'-9 1/2"
10'-0"
2'-0"
6'-8"
31/2"
6'-8"
2'-6"
2'-8"
31/2"
5 1/4"
6" 6'-10 7/8" 3'-4 7/8" 1'-9"
1'-9"
205 206 SCREEN
13'-0"
3'-0"
FAMILY PORCH
3'-9"
6'-8"
UP 8"
ENTRY/ 1/2 12/0 x 13/0
RECEPTION BATH
DINING
UP 6"
UP 8"
LAUN. KITCHEN 9' CEILING
DN.
9' CEILING 9' CEILING 9' CEILING 71/2 "
7'-9"
9' CEILING 12/0 x 11/6 DN.
6'-0"
4'-0"
6'-0"
8' X 8' O.H.D. 13/6 x 10/0 71/2 "
DN.
2'-0"
6" 2'-1" 31/2" 7'-111/4" 31/2" 1'-9" 3'-6" 31/2" 5'-10" 31/2" 2'-3 3/4" 7 1/2 "
3'-0"
202
6'-8"
16' X 8' O.H.D. A
AW251 CL.
2'-0"
3'-0"
6'-8"
R.O. 2'-4 7/8 " x 2'-4 7/8"
6"
C/L OF
HEADER @ O.H.D. HT
COLUMN
244DH2836 244DH2836 244DH2836 2 - 244DH3050
6"
6"
6"
2'-0"
R.O. 2'-8" x 3'-6" R.O. 2'-8" x 3'-6" R.O. 2'-8" x 3'-6" R.O. 6'-0" x 5'-0"
COVERED A
COLUMN
3'-0"
HEADER @ 83" AFF HEADER @ 83" AFF HEADER @ 83" AFF HEADER @ 83" AFF
C/L OF
C/L OF PORCH A3.1
COLUMN BASE
5/4 DECKING
1'- 0"
COLUMN
COLUMN
C/L OF
C/L OF
BASE
BASE
2'-0" 8'-0" 2'-0" 2'-5" 16'-0" 3'-0" 2'-7" 1'- 0" 4'-9" 4'-9" 1'-0" 2'-10" 6'-5" 9'-4" 12'-6" 6'-5" 11'-6" 6"
97'-0"
FRAMING PLAN
1,274 sq ft
MAIN LEVEL
A2.3
1/4" = 1'-0"
WILLISTON, NORTH DAKOTA
LOT 2 CREEKSIDE RIDGE
CASTLETON
TIMBERFRAME
CONSTRUCTION
PERMIT/PRICING
DESCRIPTION
DOCUMENT
DOCUMENT
ISSUE
05-19-08
03-18-08
12-14-07
DATE
18'-9"
NO.
6
3
5
2
1
6"
6"
HEADER @ 83" AFF HEADER @ 83" AFF
LINE OF HOUSE WALLS BELOW LINE OF HOUSE WALLS BELOW
3'-0"
LINE OF GARAGE WALLS BELOW
WALL RAIL
5'-11/2"
BEDROOM #3
12'-21/2"
8' CEILING
11/0 x 12/6 DN. 16
RISERS
LIN.
26'-0"
2'-8" 3'-0"
306
4'-3"
304
6'-8" 6'-8"
300
31/2" 4'-5" 31/2" 2'- 1" 31/2"
2'-4"
6'-8"
31/2"
26'-0"
CL.
6'-8"
2'-4"
6'-8"
2'-8"
LINE OF SCREEN PORCH BELOW
5 1/2"
31/2"
2'-1"
301 305
31/2"
B B
81/2"
A3.2 31/2" 4'-0" 3'-3 1/2" 5 1/2" A3.2
SHARED
3'-10 1/2"
2'-4"
302
BATH 6'-8"
BEDROOM #2
8' CEILING
12'-4"
8' CEILING
10/6 x 12/6
5'-6 1/2"
4'-0"
303
CL. 6'-8"
60" x 32"
TUB/SHOWER
UNIT
6"
2 - 244DH3050
6"
R.O. 6'-0" x 5'-0"
A HEADER @ 83" AFF
A3.1
LINE OF PORCH BELOW
12'-1" 6'-8"
18'-9"
FRAMING PLAN
UPPER LEVEL
A2.4
1/4" = 1'-0"
WILLISTON, NORTH DAKOTA
LOT 2 CREEKSIDE RIDGE
CASTLETON
TIMBERFRAME
1'-0"
HEEL
TOP OF U.L.
118'-3" WALLS
BLOWN-IN ATTIC INSULATION
DESIGN REVIEW
CONSTRUCTION
PERMIT/PRICING
TOP OF U.L. DOORS R.O. 1'- 0" MINIMUM R-38
TOP OF U.L. WINDOWS R.O.
DESCRIPTION
DOCUMENT
DOCUMENT
H-SERIES HURRICANE TIES
@ TRUSS/TOP PLATE @ REQUIRED SPACING
ISSUE
BY SIMPSON-STRONG TIE
05-19-08
03-18-08
12-14-07
DATE
8'-11/8"
6'-11"
NO.
6
3
5
2
1
1'-03/4"
7/8" TOUNGE & GROOVE SUB-FLOORING
TOP OF M.L.
1/8 "
109'-1 WALLS
11 7/8" TGI JOISTS
R-13 BATT INSULATION
@ RIM JOIST
9'-11/8"
6'-11"
TOP OF CONC
91'-0 3/4" SLAB FLOOR
SECTION
4" MINIMUM THICKNESS
6 MIL. GRANULAR VAPOR BARRIER
SLAB:
1/2" RIDGID INSULATION
3500 PSI CONCRETE
WALL
8" x 16" CONTINUOUS FOOTINGS
A3.1
1/2" = 1'-0"
WILLISTON, NORTH DAKOTA
LOT 2 CREEKSIDE RIDGE
CASTLETON
TIMBERFRAME
CONSTRUCTION
PERMIT/PRICING
DESCRIPTION
DOCUMENT
DOCUMENT
ISSUE
05-19-08
03-18-08
12-14-07
DATE
NO.
6
3
5
2
1
12
8'-11/8"
SHARED
6'-11"
BEDROOM #2
BATH
TOP OF U.L.
110'-1 7/8"
SUB-FLOOR
TOP OF M.L. 1/8"
109'-1
WALLS
1'-0 3/4"
UPSET LVL BEAM\
1'-0" PRE-ENGINEERED WOOD SIZE T.B.D. 1'-0"
TRUSSES DRYWALL ARCH TOP OF M.L. DOORS R.O.
ATTIC INSULATION SHOULDER @ 7'-0" TOP OF M.L. WINDOWS R.O.
MIN. R-38 ARCH TO 8'-0"
OWNER'S
UTILITY GALLERY GREAT ROOM
CLOSET
9'-1 1/8"
STAIR DN. STAIR UP
6'-11"
BEYOND BEYOND
75/8"
TOP OF M.L. SUB-FLOOR
100'-0"
6" CURB @ GARAGE
TOP OF FROST WALL TOP OF 3/4 "
4" GARAGE FLOOR SLAB 98'-9
CONC. WALL
1'-2 1/4"
TOP OF L.L. DOORS R.O.
TOP OF L.L. WINDOWS R.O.
1'-0"
11 7/8" I- JOISTS
4'-0"
@ 16" O.C.
CEILING
5" CLEAN GRANULAR MATERIAL DOWN 12"
TOP OF FOOTING BELOW SLAB
6'-11"
STAIR UP
7'-9"
6'-101/2"
MECHANICAL/ L.L. FAMILY
STORAGE BEYOND ROOM
75/8"
TOP OF CONC
91'-0 3/4"
SLAB FLOOR
BUILDING
SECTION
A3.2
1/4" = 1'-0"
WILLISTON, NORTH DAKOTA
LOT 2 CREEKSIDE RIDGE
W W W
CASTLETON
SUMP
CROCK
TIMBERFRAME
HVAC Legend
C
W Supply Register
3-STALL
C
C
DESIGN REVIEW
CONSTRUCTION
PERMIT/PRICING
W
W.H.
W
FLOOR
DESCRIPTION
DOCUMENT
DOCUMENT
DRAIN
ISSUE
05-19-08
03-18-08
12-14-07
DATE
NO.
6
3
5
2
1
W
W W W W
C
W
C
C
C
W W
LAYOUT
W
SUPPLY REGISTER
IN WALL @ 1/2 BATH
A4.1
1/4" = 1'-0"
*NOTE: DUCT WORK FOR MAIN LEVEL HEATING BASED
ON PRELIMINARY FLOOR JOIST LAYOUT. HVAC
CONTRACTOR TO VERIFY LAYOUT PRIOR
TO INSTALLATION
TO INSTALLATION
UPPER LEVEL HVAC
W
C
C
C
W
Cold Air Return
Supply Register
HVAC Legend
ISSUE
NO. DATE DESCRIPTION
CONSTRUCTION
3 05-19-08 3-STALL
LEVEL HVAC DOCUMENT
4
LAYOUT LOT 2 CREEKSIDE RIDGE
5
A4.2 WILLISTON, NORTH DAKOTA
6 PLAN NO.: 07-064
Copyright © Homescape Design Group, 2008
WILLISTON, NORTH DAKOTA
LOT 2 CREEKSIDE RIDGE
CASTLETON
LINE OF JOISTS
TIMBERFRAME
8'-8 1/2"
3-STALL
UPSET LVL BEAM
HEADER SIZE T.B.D.
HEADER
DESIGN REVIEW
CONSTRUCTION
PERMIT/PRICING
SIZE T.B.D.
DESCRIPTION
DOCUMENT
DOCUMENT
HEADER
ISSUE
DROPPED LVL BEAM
SIZE T.B.D.
05-19-08
03-18-08
12-14-07
DATE
1'-4" 1'-4"
NO.
6
3
5
2
1
LINE OF JOISTS
6'-9 1/2"
8'-81/2"
8'-8 1/2"
UPSET LVL
BEAM SIZE T.B.D.
C/L OF
COLUMN
HEADER
17'-31/2"
1'- 4" 1'-4"
FLOOR JOIST
LAYOUTS
13'-6 3/4" 16'-11 3/4"
A5.1
1/4" = 1'-0"
UPPER LEVEL FLOOR JOIST LAYOUT
*NOTE: PRELIMINARY LAYOUT ONLY! CONFIRM WITH JOIST MANUFACTURER & LOCAL BUILDING CODES*
WILLISTON, NORTH DAKOTA
LOT 2 CREEKSIDE RIDGE
CASTLETON
TIMBERFRAME
CONSTRUCTION
PERMIT/PRICING
DESCRIPTION
DOCUMENT
DOCUMENT
ISSUE
05-19-08
03-18-08
12-14-07
DATE
HAND FRAME DOWN HAND FRAME DOWN
TO ROOF TO ROOF
START GARAGE TRUSS
LAYOUT HERE 1'-0" 14'-3 3/4"
NO.
1'-0"
6
3
5
2
@ 24" O.C.
1
1'-0"
1'-0"
LINE OF TRUSS
B B
A
A
CENTER LINE OF STRUCTURAL TIMBER BEAM
1'-0"
B B
HI
P
HI
P
B B BEARING POINT ELEVATION
EY
A - TOP OF M.L. WALLS 109'-1 1/8 "
LL
B - TOP OF U.L. WALLS 118'-27/8 "
B B
VA
VA
LL
EY
B B
RIDGE
RIDGE RIDGE
1'-6"
A
A
B B C/L OF
BEAM
RIDGE
B B
B B
B B RIDGE
12'-0"
V
A
Y B B
LL
E
EY
LL
A
V
P
HI
HI
B B
P
1'-0"
1'-0"
B B C/L OF
1'-0"
BEAM
1'-6"
1'-0"
14'-3 3/4"
1'-0"
LAYOUT
TRUSS
ROOF
A5.2
1/4" = 1'-0"
WILLISTON, NORTH DAKOTA
LOT 2 CREEKSIDE RIDGE
CASTLETON
TIMBERFRAME
3-STALL
16/0 x 17/0
GUEST
BEDROOM
8' CEILING GAMES
CARPET FLOOR
12/0 x 12/6
UP 14
RISERS
CL.
DESIGN REVIEW
CONSTRUCTION
PERMIT/PRICING
UNEXCAVATED
DESCRIPTION
8' CEILING
DOCUMENT
DOCUMENT
7' CEILING
ISSUE
W.H. FURNACE
FLOOR
DRAIN
05-19-08
03-18-08
12-14-07
DATE
U/C REF.
NO.
6
3
5
2
UNIT
1
STORAGE GAMES
SINK.
7' CEILING
CONC. FLOOR BATH CARPET FLOOR
8' CEILING 16/0 x 7/0
TILE
FLOORING
SEAT
36" x 72"
TUB
TILE
SHOWER
OWNER'S
OWNER'S RETREAT
BATH STEP CEILING
9' CEILING CARPET FLOOR
TILE FLOORING 13/6 x 13/6 GREAT
ROOM
9' CEILING
CARPET FLOOR
16/6 x 14/6
DN. 14
UP 16
RISERS
RISERS
9' CEILING
8' CEILING
OWNER'S
6" CURB
GARAGE CABINET
SLOPE FLOOR ABOVE STOOL CLOSET
9' CEILING
CARPET FLOOR
DW. ARCH
GALLERY
9' CEILING
UTILITY TILE FLOORING
DRY
ENTRY/ DINING PORCH
RECEPTION
RANGE
9' CEILING 12/0 x 13/0
9' CEILING 1/2 BATH LAUNDRY KITCHEN WOOD FLOORING
12/0 x 11/6
WASH
SEAT
CL.
PLAN
COVERED
PORCH
D1.1
1/4" = 1'-0"
MAIN LEVEL DESIGN PLAN
1,274 sq ft
WILLISTON, NORTH DAKOTA
LOT 2 CREEKSIDE RIDGE
CASTLETON
TIMBERFRAME
CONSTRUCTION
PERMIT/PRICING
DESCRIPTION
DOCUMENT
DOCUMENT
ISSUE
05-19-08
03-18-08
12-14-07
DATE
NO.
6
3
5
2
1
BEDROOM #3
8' CEILING
CARPET FLOOR
11/0 x 12/6
DN. 16
RISERS
LIN.
SHARED
BATH BEDROOM #2
8' CEILING
8' CEILING
TILE FLOOR
CARPET FLOOR
10/6 x 12/6
CL.
60" x 32"
TUB/SHOWER
UNIT
DESIGN PLAN
UPPER LEVEL
D1.2
1/4" = 1'-0"
WILLISTON, NORTH DAKOTA
LOT 2 CREEKSIDE RIDGE
SUMP
CASTLETON
STEP
CROCK
Electrical Key
TIMBERFRAME
STEP
3-STALL
Keyless
3
Light
3
Lamp
Ceiling Flush
Mount
FLOOR
SD PLUG Decorative Surface
Mount
Wall Mount
SD
DESIGN REVIEW
CONSTRUCTION
W.H.
PERMIT/PRICING
SD
FLOOR Fluorescent Cloud
DESCRIPTION
DRAIN
DOCUMENT
DOCUMENT
3
Outlet
ISSUE
C Outlet @ Countertop
Height
05-19-08
03-18-08
Bathroom Fan
12-14-07
DATE
C
Bathroom Fan/Light
NO.
6
3
5
2
C
1
Switch
Ceiling Fan
STEP
STEP
OUTLET ABOVE
MANTLE
STEP
STEP
3 3
C C
3
SD
FLOOR
SD PLUG
SD
3 3
WATERPROOF
3 OUTLET
LEVEL ELECTRICAL
CABINET
C
MOUNTED
3
OUTLET
3
C
FAN
W/ LIGHT
3 C C C 3
WATERPROOF
OUTLET
PLAN
MAIN LEVEL ELECTRICAL PLAN
1/4" = 1'-0"
E1.1
*NOTE: ELECTRICAL CONTRACTOR TO VERIFY
ALL FIXTURES, SWITCHES AND OUTLETS
PRIOR TO CONSTRUCTION.
*NOTE: VERIFY LAYOUT WITH FLOOR JOIST AND HVAC LAYOUTS
WILLISTON, NORTH DAKOTA
LOT 2 CREEKSIDE RIDGE
CASTLETON
TIMBERFRAME
CONSTRUCTION
PERMIT/PRICING
DESCRIPTION
DOCUMENT
DOCUMENT
ISSUE
05-19-08
03-18-08
12-14-07
DATE
NO.
6
3
5
2
1
STEP
Electrical Key
STEP
STEP
6 Inch Recessed Can
Keyless
Light
3
Lamp
Ceiling Flush
SD SD Mount
Decorative Surface
Mount
3
SD
Wall Mount
C
Fluorescent Cloud
Outlet
C Outlet @ Countertop
3 Height
Bathroom Fan
Bathroom Fan/Light
Switch
SD Smoke Detector
Ceiling Fan
UPPER LEVEL
ELECTRICAL
PLAN E1.2
1/4" = 1'-0"