Sie sind auf Seite 1von 17

WILLISTON, NORTH DAKOTA

LOT 2 CREEKSIDE RIDGE


CASTLETON
TIMBERFRAME
PLAN INDEX

PLAN NO.: 07-064


A0.0 - Master Page
A1.1 - Entry & Rear Elevations
A1.2 - Left & Right Elevations

3-STALL
A2.1 - Foundation Plan
A2.2 - Lower Level Framing Plan
A2.3 - Main Level Framing Plan
A2.4 - Upper Level Framing Plan
A3.1 - Wall Section
A3.2 - Building Section
A4.1 - Lower & Main Level HVAC Layout
A4.2 - Upper Level HVAC Layout
A5.1 - Floor Joist Layouts
A5.2

DESIGN REVIEW

CONSTRUCTION
PERMIT/PRICING
- Roof Truss Layout
D1.1

DESCRIPTION
- Lower & Main Level Design Plan

DOCUMENT

DOCUMENT
D1.2 - Upper Level Design Plan
E1.1 - Lower & Main Level Electrical Plan

ISSUE
E1.2 - Upper Level Electrical Plan

05-19-08
03-18-08
12-14-07
DATE
GENERAL PROJECT NOTES

NO.

6
3

5
2
1
1. Building design and construction are complex
endeavors. Although the designer and

Copyright © Homescape Design Group, 2008


consultants have performed their services with
due care and diligence, they cannot guarantee
perfection nor can they anticipate every
possible contingency.

Construction plans are conceptual in nature in


the sense that some details and instructions
have been omitted under the assumption that
the General Contractor and Subcontractors
will also perform their services with due care
and diligence.

2. Any discrepancy discovered by the use of


these plans shall be reported to the designer
immediately. Failure to notify shall relieve the
designer from the responsibility of all
subsequent consequences.

3. Changes made to these plans without the


express consent of the designer are
unauthorized and shall relieve the designer

Castleton - Timberframe
from the responsibility of consequences due to
such changes.

4. References in these plans to 'Code' refers to


all federal, state, county and local codes, laws
and regulations including building, engineering,
sanitation and planning department
requirements. Any and all work shall be
performed in accordance with these
requirements.

PLAN LEGEND
- Indicates floor elevation change

A
A2.1
- Indicates section / detail indicator

100'-0" - Indicates relative elevation reference CONCRETE FOOTING / ROUGH-IN NOTES MECHANICAL SYSTEMS ELECTRICAL NOTES INSULATION NOTES
FLATWORK NOTES (If applicable)
1. 2x4 walls to receive minimum R-13 insulation.
FRAMING PLUMBING 1. See page E1.1 & E1.2 for electrical layout
- Indicates non-bearing wall 1. For details see page A2.2, A2.3, A2.4, A3.1 1. Fixture selections by contractor in coordination including general fixture locations and switching. 2x6 walls to receive minimum R-21 insulation.
FOOTINGS / FLATWORK
& A3.2 with owner. Coordinate requirements of 2. Outlets shown on plan are to be verified by 2. All foam insulation to consist of closed cell
1. For typical wall and footing details see page
2. Provide all connectors and support hangers to selected fixtures with subcontractors. Provide electrical contractor to meet or exceed all product.
- Indicates bearing wall A2.1, A3.1 & A3.2
comply with local building codes. "low flow" fixtures meeting state and local code requirements. 3. Joist rim board to receive insulation. Take
2. The general contractor and concrete
3. Floor system layout to be 11 7/8" I-Joist. regulations. 3. Stair lighting and switching to be provided to special care to seal around all penetrations.
subcontractors shall field verify rebar
INTERIOR DOOR DETAIL specifications, foundation wall and footing Minumum deflection L/480. 2. Take care to locate all waste lines to minimize meet code requirements. 4. Attic to have minimum R-38 insulation.
Interior door style to be selected by owner 4. Truss system layout and loading to be noise. Insulate where possible. 4. Provide all smoke detectors, heat sensors and 5. Fill around all exterior doors and windows with
elevations based on field conditions.
confirmed by local supplier @ maximum local 3. Take care to locate plumbing vents away from carbon monoxide detectors as required by non expanding spray foam.
3. The general contractor and concrete
code requirements. valleys, vertical walls, etc. Locate on sunny code. 6. Seal all penetrations between floors per fire
Door width and height subcontractors shall field verify daylight,
5. All dimensions are frame to frame including roof areas away from entry elevation sight 5. See legend on electrical pages for electrical code requirements.
walkout and frost wall locations and sizes.
7/16" sheathing at exterior walls. lines. symbols. 7. Provide acoustic batt insulation between bath,
4. Assumed design soil bearing pressure =
6. Align studs with joists, rafters and truss 4. Water heater to be minimum 50 gallon. 6. All recessed cans to be "I.C." units in bedrooms and laundry rooms.
2'-6" 2,000 psf.
100

6'-8" 5. Concrete = FC 3,500 psi. locations. unconditioned ceiling space.


6. All foundation walls to include waterproofing 7. All header sizes and materials to be confirmed 7. Fixtures to be provided by contractor
Reference number to door mastic and membrane. by local engineer.
schedule. 8. Lumber grade to be #2 spf hemlock, douglas fir PLUMBING LEGEND
7. Provide anchor bolts to meet local code
or better. All nails and screws to be coated.
DRYWALL NOTES
requirements. - Indicates Hose bib
8. Confirm with local engineer reinforcement 9. The general contractor, suppliers and
subcontractors shall verify and approve all 1. All ceilings to be 5/8" type "X" gypsum board
WINDOW DETAIL requirements for specific loading and backfill where required by code and where backing is INTERIOR FINISHES
conditions. window and door sizes.
Manufacturer to be verified by owner 10. Provide blocking for towel bars, toilet paper - Gas or Electric meter as noted on 24" o.c.
9. All perimeter foundation walls to receive elevations 2. All walls to be 1/2" type "X" round edge gypsum CABINETS AND APPLIANCES
insulation from footing to grade - minumum R-5 holders, handrails, cabinets and any other
board. 1. Provide cold water supply for refrigerator.
or better. permanent fixtures.
3. All drywall board to be glued and screwed to 2. Cook top - Electric
HEADER @ 80" AFF

11. Draft stopping and fire blocking to be provided


Window rough GAS - Indicates gas stub backing. 3. Oven - Electric
opening CONCRETE FLATWORK per code requirements.
4. Drywall ceiling to be nailed to 2x8 blocking @ 4. Provide hot and cold water supply and waste
12. Provide continuous bead of construction
R.O. 1'-0" x 1'-0"

1. There shall be a minimum 5" granular material all interior walls, not to roof trusses to avoid line for dishwasher
under all slabs on grade. adhesive between sill plate and sub floor. HVAC
nail pops due to predicted truss movement. 5. Dryer - Gas/Electric
Bottom of Header 2. Concrete slabs on grade shall be minimum 4" 13. Provide sill seal between sill plate and 1. Provide combustion air supply for furnace and
5. All floors to receive adequate protection during 6. Furnace - Gas
thick. concrete. hot water heater as required by code and local
hang and finish of drywall. 7. Hot Water Heater - Gas

MASTER
regulations.
1234

3. All slabs on grade shall have a control or 6. Drywall contractor to be responsible to 8. Cabinetry supplier to field verify all dimensions
construction joint at a maximum spacing in feet WINDOWS AND DOORS 2. Floor drain to be provided in all mechanical
remove all drywall scrap and waste from site. prior to ordering and fabricating cabinetry.
of three times the slab thickness in inches 1. Windows and patio doors specified on plan are areas. Location of drains not specified on plan
Reference number to Andersen 200 series windows unless noted 7. All drywall to be primed prior to installation of
each way. Maintain aspect ratio not to shall be decided by the general contractor in
window manufacturer interior trim.

PAGE
exceed 1.5. (To be cut within 24 hours of otherwise. coordination with sub contractors.
2. See pages A2.2, A2.3 & A2.4 for individual 8. Test moisture content to confirm below
pouring concrete.) 3. 5 Ton forced air heating and cooling system.
model numbers and rough opening sizes. maximum content required by drywall
4. All slabs in heated areas to receive ridgid 4. Furnace efficiency to be 90% or greater.
3. All windows and doors to have a maximum air manufacturer. (Provide verification.)
SITE WORK & GRADING NOTES insulation below but do not separate slab from
infiltration rating of 0.3 cfm.
5. Air conditioner to have SEER rating of 13 or FLOORING LEGEND
footings to act as vapor barrier. greater. (Optional)
4. All windows to have Low E argon filled glass. 6. Programmable thermostat to be provided.
TREE REMOVAL
Verify with manufacturer. 7. Heat recovery ventilator to be provided. - Carpet flooring
1. Excavator shall use extreme caution when
excavating around trees to be preserved. (Optional)
Hand excavate around exposed roots. 8. Provide vent fan with back draft damper in all
bathrooms. - Tile or vinyl flooring
EXCAVATION & BACKFILL 9. Any and all duct work in attic to be insulated.
1. All excavation and backfill shall be conducted in 10. All duct work to be sealed with mastic or tape.
11. Zone upper level seperate. (Optional) - Wood
strict accordance with the soils report.

A0.0
2. Provide foundation drain per soils report.
3. Maintain positive drainage away from
- Decking
foundation @ minimum 5% grade

NOT TO
SCALE
WILLISTON, NORTH DAKOTA
12

LOT 2 CREEKSIDE RIDGE


10 *OPTIONAL
4" SQUARE

CASTLETON
TIMBER BRACKET CHIMNEY

TIMBERFRAME

PLAN NO.: 07-064


10/12 ROOF PITCH

10/12 ROOF PITCH

3-STALL
CONTINUOUS RIDGE VENT
10/12 ROOF PITCH
ROOFING:
30 YEAR LANDMARK 10/12 ROOF PITCH TOP OF U.L.
118'-3"
BY CERTAINTEED WALLS
TOP OF U.L. DOORS R.O.
6" BAND BOARD
TOP OF U.L. WINDOWS R.O.
10/12 ROOF PITCH

8'-11/8"
6'-11"

DESIGN REVIEW

CONSTRUCTION
PERMIT/PRICING
DESCRIPTION

DOCUMENT

DOCUMENT
SOFFIT: VINYL VENTED TOP OF U.L. 7/8"
110'-1
FASCIA: 6" ALUM. WRAP SUB-FLOOR
FRIEZE BOARD: 6" REVEAL TOP OF M.L. 1/8"
109'-1

ISSUE
ALUM. WRAP WALLS

1'-0 3/4"
1'-0"
1'-0" 1'-0"
TOP OF M.L. DOORS R.O.

05-19-08
03-18-08
5" FIBER CEMENT TOP OF M.L. WINDOWS R.O.

12-14-07
DATE
CORNER

NO.

6
3

5
2
9'-1 1/8"

1
6'-11"
6" REVEAL CLAPBOARD

Copyright © Homescape Design Group, 2008


FIBER CEMENT SIDING

TOP OF CAP

TOP OF M.L. SUB-FLOOR

2'-3"
100'-0"

TOP OF 3/4 "


98'-9
CONC. WALL

1'-2 1/4"
TOP OF L.L. DOORS R.O.
TOP OF L.L. WINDOWS R.O.
8' x 8' GARAGE DOOR 16' x 8' GARAGE DOOR
WINDOW & DOOR TRIM:

4'-0"
STEEL STEEL W/ 6 WINDOW COLUMNS: ALUMINUM FRAME SCREEN
MANUFACTURER T.B.D. MANUFACTURER T.B.D. 3 - 8" SQUARE CEDAR ON 5" HEAD PIECE @ PORCH
24" SQUARE CULTURED STONE 3 1/2 " SIDES AND APRON
BASE W/ CAP COLUMNS:
12" SQUARE CEDAR ON TOP OF
CULTURED STONE

6'-11"

7'-9"
5/4" DECKING MATERIAL W/ 6" CAP & 8" BASE FOOTING
W/ CULTURED CAP
OVER 2x10 TRT. DECK JOISTS

TOP OF CONC
91'-0 3/4"
SLAB FLOOR

ENTRY ELEVATION
TOP OF
CHIMNEY

12
*OPTIONAL 10
METAL SADDLE &
FLASHING AS
REQUIRED @ CHIMNEY

10/12 ROOF PITCH


13'-5 3/8"

10/12 ROOF PITCH


CONTINUOUS RIDGE VENT

10/12 ROOF PITCH

10/12 ROOF PITCH TOP OF U.L.


118'-3"
WALLS
TOP OF U.L. DOORS R.O.
TOP OF U.L. WINDOWS R.O.
10/12 ROOF PITCH ROOFING:
30 YEAR LANDMARK
BY CERTAINTEED

8'-1 1/8"
6'-11"
TOP OF U.L. 7/8 "
110'-1
SUB-FLOOR
TOP OF M.L. 1/8"
109'-1
WALLS

1'-0 3/4"
1'-0"
1'-0" 1'-0"

ELEVATIONS
1'-0"
TOP OF M.L. DOORS R.O.
TOP OF M.L. WINDOWS R.O.
10'-10 1/2"

6" REVEAL CLAPBOARD


FIBER CEMENT SIDING

9'-1 1/8"
6'-11"

ENTRY &
5" FIBER CEMENT
CORNER

REAR
TOP OF M.L. SUB-FLOOR TOP OF M.L. SUB-FLOOR
100'-0"

TOP OF TOP OF 3/4 "


98'-9
CONC. WALL CONC. WALL

1'-2 1/4"
TOP OF L.L. DOORS R.O.
TOP OF L.L. WINDOWS R.O.
CULTURED STONE WINDOW & DOOR TRIM:
4'-0"

4'-0"
ALUMINUM FRAME SCREEN
W/ CULTURED CAP 5" HEAD PIECE
@ PORCH
3 1/2 " SIDES AND APRON
COLUMNS: 6" BAND BOARD
TOP OF FOOTING 12" SQUARE CEDAR ON TOP OF FOOTING

6'-11"

7'-9"
W/ 6" CAP & 8" BASE EGRESS WINDOWS BELOW GRADE
TOP OF CO NC. SLAB

PROVIDE WINDOW WELL


ROUGH OPENING
3'-4 1/2"

TO WINDOW

TOP OF CONC
91'-0 3/4"
SLAB FLOOR

A1.1
1/4" = 1'-0"
REAR ELEVATION
WILLISTON, NORTH DAKOTA
LOT 2 CREEKSIDE RIDGE
CASTLETON
TIMBERFRAME

PLAN NO.: 07-064


3-STALL
DESIGN REVIEW

CONSTRUCTION
PERMIT/PRICING
DESCRIPTION

DOCUMENT

DOCUMENT
ISSUE
7'-2" CONTINUOUS RIDGE VENT CONTINUOUS RIDGE VENT 7'-2"

10/12 ROOF PITCH 10/12 ROOF PITCH


ROOFING: ROOFING:

05-19-08
03-18-08
12 30 YEAR LANDMARK 30 YEAR LANDMARK

12-14-07
DATE
TOP OF
BY CERTAINTEED BY CERTAINTEED
10 CHIMNEY

12 12

NO.

6
3

5
2
1
10 10

Copyright © Homescape Design Group, 2008


13'-5 3/8"
A21
R.O. 2'-0 5/8" x 2'-0 5/8"
TOP OF U.L. HEADER @ 6'-6" ABOVE TOP OF U.L.
118'-3" TOP OF M.L. WALL 118'-3"
12 WALLS WALLS
TOP OF U.L. DOORS R.O. TOP OF U.L. DOORS R.O.
10 TOP OF U.L. WINDOWS R.O.
*OPTIONAL
TOP OF U.L. WINDOWS R.O.
METAL SADDLE &
FLASHING AS
12
GABLE VENT: REQUIRED @ CHIMNEY
12
18" x 24" 10
W/ TRIM

8'-11/8"
10

8'-11/8"
6'-11"

6'-11"
12

6'-6"
6" BAND BOARD CEDAR TIMBER
BEAMS
10
SOFFIT: WOOD SOFFIT: WOOD
2'-6"

FASCIA: 6" ALUM. WRAP TOP OF U.L. FASCIA: 6" ALUM. WRAP TOP OF U.L.
7/8" 7/8"
FRIEZE BOARD: 6" REVEAL 110'-1 FRIEZE BOARD: 6" REVEAL SUB-FLOOR 110'-1
SUB-FLOOR
ALUM. WRAP TOP PLATE OF M.L. WALL TOP OF M.L. TOP PLATE OF M.L. WALL ALUM. WRAP TOP OF M.L.
109'-1 1/8" 109'-1 1/8"
WALLS WALLS

1'-0 3/4"

1'-0 3/4"
1'-0"
1'-0" 1'-0" 1'-0" 1'-0" 1'-0"

6" REVEAL CLAPBOARD TOP OF M.L. DOORS R.O. COLUMNS: 6" BAND BOARD TOP OF M.L. DOORS R.O.
FIBER CEMENT SIDING TOP OF M.L. WINDOWS R.O. 3 - 8" SQUARE CEDAR ON TOP OF M.L. WINDOWS R.O.
24" SQUARE CULTURED STONE
BASE W/ CAP
COLUMNS: 6" REVEAL CLAPBOARD
3 - 8" SQUARE CEDAR ON FIBER CEMENT SIDING
5" FIBER CEMENT 24" SQUARE CULTURED STONE

9'-1 1/8"
9'-1 1/8"
CORNER BASE W/ CAP 5" FIBER CEMENT

6'-11"

6'-11"
CORNER

TOP OF CAP TOP OF CAP


CULTURED STONE
W/ CULTURED CAP TOP OF M.L. SUB-FLOOR TOP OF M.L. SUB-FLOOR
2'-3"

2'-3"
100'-0" 100'-0"

TOP OF 3/4 " TOP OF 3/4 "


98'-9 98'-9
CONC. WALL CONC. WALL

1'-2 1/4"

1'-2 1/4"
TOP OF L.L. DOORS R.O. TOP OF L.L. DOORS R.O.
TOP OF L.L. WINDOWS R.O. TOP OF L.L. WINDOWS R.O.
WINDOW & DOOR TRIM: WINDOW & DOOR TRIM:
4'-0"

4'-0"
5" HEAD PIECE SLOPE CONC. PATIO 5" HEAD PIECE
3 1/2 " SIDES AND APRON 5% FOR DRAINAGE 3 1/2 " SIDES AND APRON
ALUMINUM FRAME SCREEN
TOP OF FOOTING @ PORCH CULTURED STONE
6'-11"

6'-11"

7'-9"
7'-9"
W/ CULTURED CAP

COLUMNS:
12" SQUARE CEDAR ON
W/ 6" CAP & 8" BASE

TOP OF CONC 3/4" TOP OF CONC 3/4"


91'-0 91'-0
SLAB FLOOR SLAB FLOOR

LEFT ELEVATION RIGHT ELEVATION

ELEVATIONS
LEFT &
RIGHT
A1.2
1/4" = 1'-0"
WILLISTON, NORTH DAKOTA
LOT 2 CREEKSIDE RIDGE
CASTLETON
TIMBERFRAME

PLAN NO.: 07-064


3-STALL
DESIGN REVIEW

CONSTRUCTION
PERMIT/PRICING
DESCRIPTION

DOCUMENT

DOCUMENT
ISSUE

05-19-08
03-18-08
12-14-07
DATE
85'-0"

36'-0" 49'-0"

NO.

6
3

5
2
1
11'-8" 6'-6" 15'-0" 3'-6" 7'-6" 3'-6" 1'-4"
VERIFY OPENING SIZE

Copyright © Homescape Design Group, 2008


VERIFY OPENING VERIFY OPENING
PER WINDOW SELECTED SIZE PER WINDOW SIZE PER WINDOW
SELECTED SELECTED
CONC. WALL
T.O.F. = 90'-9 3/4"
T.O.W. = 98'-9 3/4"

8"
8"
CONC. WALL
T.O.F. = 94'-9 3/4 "
2'-0"

T.O.W. = 98'-9 3/4 "

16"x8" CONC. FTG.


SUMP

8" CONC WALL


CROCK

16"x8" CONC. FTG.

7'- 4 1/2"
FROSTW ALL
6" CONC
8' POURED 16" x 8" CONC. FOOTING
FOR 2 x 6 BEARING WALL
CONC. WALLS CONC. WALL

12'-5"
T.O.F. = 90'-9 3/4"

13'-1 1/4"
16"x8" CONC. FTG.

1'-4"
T.O.W. = 98'-9 3/4"

15'-0"
4" CONCRETE SLAB FLOOR
@ 3" ABOVE FOOTINGS

17'-0 1/4"
8" CONC WALL
16"x8" CONC. FTG.

6" CONC
FROSTWALL
16"x8" CONC. FTG.

8" CONC WALL


CONC. WALL
UNEXCAVATED
20'-0"

T.O.F. = 90'-9 3/4"


8" 9'-11/2" 14'-7 1/2" 1'-0" 3'-7 1/2" 2'-5" 1'- 4" 15'-6 1/2" 8"
T.O.W. = 98'-9 3/4 " DECK FOOTINGS
CONC. WALL
26'- 0"

26'-0"
22'-0"

7'- 71/2"
T.O.F. = 94'-9 3/4 " 18"" x 18"" x 8" THICK @
T.O.W. = 98'-9 3/4 " C/L OF MIN. FROST DEPTH
BEAM POCKET
C/L OF

1'-4"
W.H. FOOTING
FLOOR
8" DRAIN 17'-5 1/2" 7'-0" 2'-0" 5'-6 1/2" 15'-8" 8"
B B
A3.2 8'-3" C/L OF A3.2
BEAM POCKET
FROSTWALL
16"x8" CONC. FTG.

6" CONC

10'-11"
11'-6 3/4"
16" x 8" CONC. FOOTING

1'-4"

10'-0"
FOR 2 x 6 BEARING WALL
6" CO NC 17'-11 1/4" 11'-5" 18'-3 3/4"
FROSTWALL
16"x8" CONC. FTG.

CONC. WALL

9'-5"
T.O.F. = 94'-93/4 "

3'-91/2"

C.L. OF 2 x 4 WALL

7'-7 3/4"
C.L. OF 2 x 4 WALL
T.O.W. = 98'-93/4"

7'- 0"
CONC. WALL

16"x8" CONC. FTG.

8" CONC WALL


T.O.F. = 94'-9 3/4 "
T.O.W. = 98'-9 3/4 "
2'-0"

4'-1 1/2"
2'-9"
2'-31/2"

1'-0"
C/L OF
2'-0"

FOOTING

CONC. WALL

8"

8"
2'-0"

DECK FOOTINGS
A T.O.F. = 90'-9 3/4"

FOOTING
C/L OF T.O.W. = 98'-9 3/4"
26" x 26" x 8" THICK @ A3.1

C/L OF
FOOTING
MIN. FROST DEPTH
FOOTING

FOOTING
C/L OF
C/L OF

1'-10" 8'-4" 1'-10" 2'-3 1/2" 16'-4" 5'-4 1/2" 1'-0" 9'-7 1/2" 38'-4 1/2"

12'-0" 24'-0" 49'-0"

85'-0" 11'- 0"

FOUNDATION
*NOTE: FIXTURE DIMENSIONS ITALICIZED

FOUNDATION
PLAN
A2.1
1/4" = 1'-0"
WILLISTON, NORTH DAKOTA
LOT 2 CREEKSIDE RIDGE
CASTLETON
TIMBERFRAME

PLAN NO.: 07-064


3-STALL
DESIGN REVIEW

CONSTRUCTION
PERMIT/PRICING
DESCRIPTION

DOCUMENT

DOCUMENT
ISSUE

05-19-08
03-18-08
12-14-07
DATE
49'-0"

14'-11" 20'-0" 11'-0" 3'- 1"

NO.

6
3

5
2
1

Copyright © Homescape Design Group, 2008


WINDOW WINDOW WINDOW
WELL WELL WELL
CXW235 - EGRESS CXW135 CXW135
R.O. 6'-0 1/8" x 3'-5 3/8 " R.O. 3'-01/2" x 3'-5 3/8 " R.O. 3'-01/2" x 3'-5 3/8 "

10"
HEADER @ 83" AFF HEADER @ 83" AFF HEADER @ 83" AFF

10"

3'-0"
SUMP
CROCK GUEST 2'-4"

103
4'- 31/2"
BEDROOM CL. 6'-8"

8' CEILING

31/2" 2'-2 1/2"


12/0 x 12/6

8" 9'-5 1/2" 31/2" 12'-0" 2'-4 1/2" 31/2" 3'-3" 31/2" 3'-3" 51/2" 15'-10" 10"

2'-7 1/2"
GAMES

@ 16" O.C. ABOVE


L.L. FAMILY

4'- 11/2"

11 7/8 " I- JOISTS


HEADER
ROOM

@ 16" O.C. ABOVE


UP 14
8' CEILING

2'-0"
6'-8"
RISERS

117/8" I- JOISTS
UPSET LVL BEAM 16/0 x 17/0
SIZE T.B.D.
106
CL.

4'- 31/2"
2'-4"

102
UNEXCAVATED

8'-6"
6'-8"
DROPPED LVL BEAM 101
SIZE T.B.D.

2'-8"
6'-8"
8' CEILING
7' CEILING

CLG. 12"
HEADER

5 1/2"

DROP
6" 2'-10" 3'-0" 6" 2'-2" 10 1/2" 3'-3" 51/2"
W.H. 2'-8"

100
FURNACE

3'-5 1/2"
FLOO R
DRAIN
6'-8"31/2" DROPPED LVL BEAM
6'-0 1/2" 2'-8" 4'-10 1/2"
B SIZE T.B.D. B
A3.2 HEADER A3.2

LINE OF SCREEN PORCH ABOVE


6'-8"
2'-6"
5 1/2"

5 1/2"
60" x 32"

@ 16" O.C. ABOVE


MECHANICAL/ TUB/SHOWER
UNIT
105

117/8" I- JOISTS

@ 16" O.C. ABOVE


STORAGE

11 7/8" I- JOISTS
8' CEILING
GAMES
CONC. FLOOR
BATH 7' CEILING

7'-5"
8' CEILING 16/0 x 7/0

6'-7"
2'-4"

104
6'-8"
17'-91/2" 31/2" 5'-0" 5 1/2" 5'-8" 31/2" 2'-2 1/2"

1'-6"
8"
A
A3.1
LINE OF PORCH ABOVE

LOWER LEVEL FRAMING PLAN

LOWER LEVEL
892 sq ft

FRAMING
PLAN A2.2
1/4" = 1'-0"
WILLISTON, NORTH DAKOTA
LOT 2 CREEKSIDE RIDGE
CASTLETON
TIMBERFRAME

PLAN NO.: 07-064


3-STALL
DESIGN REVIEW

CONSTRUCTION
PERMIT/PRICING
DESCRIPTION

DOCUMENT

DOCUMENT
ISSUE

05-19-08
03-18-08
12-14-07
DATE
97'-0"

36'-0" 49'-0" 12'-0"

6'- 0" 16'-5" 13'-7" 7'- 8" 5'-9 1/2" 9'-0" 6'-1 1/2" 6'-4" 11'-0" 3'-1" 11'-6" 6"

NO.

6
3

5
2
1

Copyright © Homescape Design Group, 2008


244DH3046 - TEMPERED
R.O. 3'-0" x 4'-6"
244FX4040-TEMP 244DH3050 244DH3050 HEADER 244DH3050 244DH3050
R.O. 4'-0" x 4'-0" R.O. 3'-0" x 5'-0" R.O. 3'-0" x 5'-0" @ 10'-10 1/2 " FROM R.O. 3'-0" x 5'-0" R.O. 3'-0" x 5'-0"

6"
HEADER @ 83" AFF HEADER @ 83" AFF HEADER @ 83" AFF M.L. SUB FLOOR HEADER @ 83" AFF HEADER @ 83" AFF

244DH2850 244DH2850
2'-0"

6"

6"
R.O. 2'-8" x 5'-0" R.O. 2'-8" x 5'-0"

2'-0"
2'-2"
*OPTIONAL

3'-4"
HEADER @ 83" AFF OF HOUSE HEADER @ 83" AFF OF HOUSE DIRECT VENT
42" X 72" GAS FIREPLACE

3'-6"
TUB 6000G - 42"
TILE

6'-6"
BY HEAT-N-GLO

1'- 101/2"
SHOWER VERIFY FRAMING
SIZE PER MANUF.
SPECIFICATIONS
6" 4'-2" 6'- 0" 5 1/2" 13'-8" 31/2" 3'-3" 31/2" 3'-3" 31/2" 5'-6" 1'-0" 3'- 6" 1'-0" 5'-4" 6"

3 - 244FX3016 - TRANSOM
OWNER'S 2'-6"

204
OWNER'S

4'-7 1/2"

OPEN RAIL
BATH 6'-8"

13'-0"
13'-21/2"

4'-4"
5'-3"
RETREAT
10'-0"

8'-10 1/2"
9' CEILING

HEADER @ 101" AFF


R.O. 9'-0" x 6'-6"
STEP CEILING

3 - 244DH3050
200 13/6 x 13/6
GREAT
HEADER @ 83" AFF OF HOUSE

C/L OF

2'-0"
6'-8"
2'-2" 9'-4" 2'-2"
DN 14
COL.
ROOM

6"
RISERS

6'-6"
COLUMN
UP 16
RISERS
9' CEILING

31/2"

C/L OF
16/6 x 14/6

OWNER'S

4'-0 1/2"
GARAGE 9' CEILING PORCH BEAM

SCREEN
R.O. 5'-4" x 5'-0"
2 - 244DH2850

5'-4 1/4"
20'-0"

CLOSET 8' CEILING SIZE T.B.D.

DOOR
2'-4"

203
SLO PE FLOOR

CLG. 12"
9' CEILING 207

2'-2"
DROP
TO DRIVE 6'-8"
26'-0"

26'-0"
6" 3'-0" 31/2" 3'-5 7/8" 3'-4 5/8" 5 1/2"

31/2"

6'-8"
2'-8"

5 1/2"
C/L OF
COLUMN

6"
HEADER UPSET LVL BEAM
UTILITY DW. ARCH SIZE T.B.D.

3'- 31/2"
GALLERY

2 - CUSTOM 1-5 TRANSOM


3'-7"
SHOULDER

3'-0"
201 9' CEILING @ 7'-0" ARCH

6'-0"
B TO 8'-0" B

16'-9 1/2"
10'-0"

UPSET LVL BEAM

2'-0"
6'-8"

31/2"

@ 16" O.C. ABOVE

HEADER @ 101" AFF


A3.2 SIZE T.B.D. A3.2

R.O. 6'-0 3/4" x 101"


PS61611R SLIDER
11 7/8 " I- JOISTS
6'-8"

6'-8"
2'-6"

2'-8"
31/2"

5 1/4"
6" 6'-10 7/8" 3'-4 7/8" 1'-9"

1'-9"
205 206 SCREEN

13'-0"
3'-0"
FAMILY PORCH

3'-9"
6'-8"
UP 8"
ENTRY/ 1/2 12/0 x 13/0
RECEPTION BATH
DINING
UP 6"
UP 8"
LAUN. KITCHEN 9' CEILING
DN.
9' CEILING 9' CEILING 9' CEILING 71/2 "

7'-9"
9' CEILING 12/0 x 11/6 DN.

6'-0"
4'-0"

6'-0"
8' X 8' O.H.D. 13/6 x 10/0 71/2 "
DN.
2'-0"

6" 2'-1" 31/2" 7'-111/4" 31/2" 1'-9" 3'-6" 31/2" 5'-10" 31/2" 2'-3 3/4" 7 1/2 "
3'-0"

202
6'-8"
16' X 8' O.H.D. A
AW251 CL.
2'-0"

3'-0"
6'-8"
R.O. 2'-4 7/8 " x 2'-4 7/8"

6"
C/L OF
HEADER @ O.H.D. HT
COLUMN
244DH2836 244DH2836 244DH2836 2 - 244DH3050
6"

6"

6"
2'-0"

R.O. 2'-8" x 3'-6" R.O. 2'-8" x 3'-6" R.O. 2'-8" x 3'-6" R.O. 6'-0" x 5'-0"
COVERED A

COLUMN
3'-0"

HEADER @ 83" AFF HEADER @ 83" AFF HEADER @ 83" AFF HEADER @ 83" AFF

C/L OF
C/L OF PORCH A3.1
COLUMN BASE
5/4 DECKING
1'- 0"

COLUMN

COLUMN
C/L OF

C/L OF
BASE

BASE
2'-0" 8'-0" 2'-0" 2'-5" 16'-0" 3'-0" 2'-7" 1'- 0" 4'-9" 4'-9" 1'-0" 2'-10" 6'-5" 9'-4" 12'-6" 6'-5" 11'-6" 6"

12'-0" 24'-0" 11'-6" 37'-6" 12'-0"

97'-0"

MAIN LEVEL FRAMING PLAN

FRAMING PLAN
1,274 sq ft

MAIN LEVEL

A2.3
1/4" = 1'-0"
WILLISTON, NORTH DAKOTA
LOT 2 CREEKSIDE RIDGE
CASTLETON
TIMBERFRAME

PLAN NO.: 07-064


3-STALL
DESIGN REVIEW

CONSTRUCTION
PERMIT/PRICING
DESCRIPTION

DOCUMENT

DOCUMENT
ISSUE

05-19-08
03-18-08
12-14-07
DATE
18'-9"

8'-1" 7'-0" 3'-8"

NO.

6
3

5
2
1

Copyright © Homescape Design Group, 2008


244DH3050 244DH3050 - TEMP.
R.O. 3'-0" x 5'-0" R.O. 3'-0" x 5'-0"

6"

6"
HEADER @ 83" AFF HEADER @ 83" AFF
LINE OF HOUSE WALLS BELOW LINE OF HOUSE WALLS BELOW

3'-0"
LINE OF GARAGE WALLS BELOW

31/2" 11'-1" 31/2" 3'-3" 31/2" 3'-3" 31/2"

WALL RAIL
5'-11/2"
BEDROOM #3

12'-21/2"
8' CEILING
11/0 x 12/6 DN. 16
RISERS

LIN.

26'-0"
2'-8" 3'-0"

306
4'-3"
304
6'-8" 6'-8"
300
31/2" 4'-5" 31/2" 2'- 1" 31/2"

2'-4"
6'-8"

31/2"

26'-0"
CL.

6'-8"
2'-4"

6'-8"
2'-8"
LINE OF SCREEN PORCH BELOW

5 1/2"

31/2"
2'-1"
301 305

31/2"
B B

81/2"
A3.2 31/2" 4'-0" 3'-3 1/2" 5 1/2" A3.2
SHARED

3'-10 1/2"
2'-4"

302
BATH 6'-8"
BEDROOM #2
8' CEILING

12'-4"
8' CEILING
10/6 x 12/6

31/2" 5'- 0" 31/2" 2'-0" 5 1/2" 10'-5" 31/2"

5'-6 1/2"
4'-0"

303
CL. 6'-8"
60" x 32"
TUB/SHOWER
UNIT

6"
2 - 244DH3050

6"
R.O. 6'-0" x 5'-0"
A HEADER @ 83" AFF
A3.1
LINE OF PORCH BELOW

12'-1" 6'-8"

18'-9"

UPPER LEVEL FRAMING PLAN


487 sq ft

FRAMING PLAN
UPPER LEVEL

A2.4
1/4" = 1'-0"
WILLISTON, NORTH DAKOTA
LOT 2 CREEKSIDE RIDGE
CASTLETON
TIMBERFRAME

PLAN NO.: 07-064


3-STALL
12
10

1'-0"
HEEL
TOP OF U.L.
118'-3" WALLS
BLOWN-IN ATTIC INSULATION

DESIGN REVIEW

CONSTRUCTION
PERMIT/PRICING
TOP OF U.L. DOORS R.O. 1'- 0" MINIMUM R-38
TOP OF U.L. WINDOWS R.O.

DESCRIPTION

DOCUMENT

DOCUMENT
H-SERIES HURRICANE TIES
@ TRUSS/TOP PLATE @ REQUIRED SPACING

ISSUE
BY SIMPSON-STRONG TIE

05-19-08
03-18-08
12-14-07
DATE
8'-11/8"

6'-11"

NO.

6
3

5
2
1

Copyright © Homescape Design Group, 2008


TOP OF U.L.
110'-1 7/8 "
SUB-FLOOR

1'-03/4"
7/8" TOUNGE & GROOVE SUB-FLOORING
TOP OF M.L.
1/8 "
109'-1 WALLS
11 7/8" TGI JOISTS
R-13 BATT INSULATION
@ RIM JOIST

H-SERIES HURRICANE TIES


TOP OF M.L. DOORS R.O. @ TOP PLATE/FLOOR JOISTS @ REQUIRED SPACING
TOP OF M.L. WINDOWS R.O. BY SIMPSON-STRONG TIE

9'-11/8"

6'-11"

TYVEK HOME WRAP


7/16" O.S.B. SHEATHING
WALL SECTION:
R-21 BATT INSULATION
1/2" DRYWALL SCREWED
TOP OF M.L.
100'-0" SUB-FLOOR
1'-21/4"

7/8" TOUNGE & GROOVE SUB-FLOORING


TOP OF
3/4"
98'-9 CONC. WALL
11 7/8 " TGI JOISTS
TOP OF L.L. DOORS R.O. R-13 BATT INSULATION
TOP OF L.L. WINDOWS R.O. @ RIM JOIST

ANCHOR BOLTS @ SILL

RIDGID PERIMETER INSULATION

MINIMUM 8" WIDE


7'-9"

FOUNDATION WALL: REBAR PER CODE


6'-11"

3500 PSI CONCRETE

TOP OF CONC
91'-0 3/4" SLAB FLOOR

SECTION
4" MINIMUM THICKNESS
6 MIL. GRANULAR VAPOR BARRIER
SLAB:
1/2" RIDGID INSULATION
3500 PSI CONCRETE

WALL
8" x 16" CONTINUOUS FOOTINGS

FOOTINGS: REBAR PER CODE


3500 PSI CONCRETE

4" DRAIN TILE


GRAVEL FILL

TYPICAL WALL SECTION - A3.1/A

A3.1
1/2" = 1'-0"
WILLISTON, NORTH DAKOTA
LOT 2 CREEKSIDE RIDGE
CASTLETON
TIMBERFRAME

PLAN NO.: 07-064


3-STALL
DESIGN REVIEW

CONSTRUCTION
PERMIT/PRICING
DESCRIPTION

DOCUMENT

DOCUMENT
ISSUE

05-19-08
03-18-08
12-14-07
DATE
NO.

6
3

5
2
1
12

Copyright © Homescape Design Group, 2008


10

10/12 ROOF PITCH

10/12 ROOF PITCH

10/12 ROOF PITCH


10/12 ROOF PITCH TOP OF U.L.
118'-3"
WALLS
TOP OF U.L. DOORS R.O.
TOP OF U.L. WINDOWS R.O.

10/12 ROOF PITCH

8'-11/8"
SHARED

6'-11"
BEDROOM #2
BATH

TOP OF U.L.
110'-1 7/8"
SUB-FLOOR
TOP OF M.L. 1/8"
109'-1
WALLS

1'-0 3/4"
UPSET LVL BEAM\
1'-0" PRE-ENGINEERED WOOD SIZE T.B.D. 1'-0"
TRUSSES DRYWALL ARCH TOP OF M.L. DOORS R.O.
ATTIC INSULATION SHOULDER @ 7'-0" TOP OF M.L. WINDOWS R.O.
MIN. R-38 ARCH TO 8'-0"

OWNER'S
UTILITY GALLERY GREAT ROOM
CLOSET

9'-1 1/8"
STAIR DN. STAIR UP

6'-11"
BEYOND BEYOND

2x6 EXTERIOR WALL


W/ MIN. R-21 BATT INSULATION

75/8"
TOP OF M.L. SUB-FLOOR
100'-0"
6" CURB @ GARAGE
TOP OF FROST WALL TOP OF 3/4 "
4" GARAGE FLOOR SLAB 98'-9
CONC. WALL

1'-2 1/4"
TOP OF L.L. DOORS R.O.
TOP OF L.L. WINDOWS R.O.

1'-0"
11 7/8" I- JOISTS
4'-0"

@ 16" O.C.

CEILING
5" CLEAN GRANULAR MATERIAL DOWN 12"
TOP OF FOOTING BELOW SLAB

6'-11"
STAIR UP

7'-9"
6'-101/2"
MECHANICAL/ L.L. FAMILY
STORAGE BEYOND ROOM

75/8"
TOP OF CONC
91'-0 3/4"
SLAB FLOOR

BUILDING SECTION B/A3.2

BUILDING
SECTION
A3.2
1/4" = 1'-0"
WILLISTON, NORTH DAKOTA
LOT 2 CREEKSIDE RIDGE
W W W

CASTLETON
SUMP
CROCK

TIMBERFRAME
HVAC Legend

PLAN NO.: 07-064


C Cold Air Return

C
W Supply Register

3-STALL
C
C

DESIGN REVIEW

CONSTRUCTION
PERMIT/PRICING
W
W.H.

W
FLOOR

DESCRIPTION

DOCUMENT

DOCUMENT
DRAIN

ISSUE

05-19-08
03-18-08
12-14-07
DATE
NO.

6
3

5
2
1
W

Copyright © Homescape Design Group, 2008


W

LOWER LEVEL HVAC


*NOTE: DUCT WORK FOR MAIN LEVEL HEATING BASED
ON IN-CEILING DUCT WORK. HVAC
CONTRACTOR TO VERIFY LAYOUT PRIOR
TO INSTALLATION

W W W W

C
W

C
C
C

LOWER & MAIN


LEVEL HVAC
W
W
C

W W

LAYOUT
W

SUPPLY REGISTER
IN WALL @ 1/2 BATH

MAIN LEVEL HVAC

A4.1
1/4" = 1'-0"
*NOTE: DUCT WORK FOR MAIN LEVEL HEATING BASED
ON PRELIMINARY FLOOR JOIST LAYOUT. HVAC
CONTRACTOR TO VERIFY LAYOUT PRIOR
TO INSTALLATION
TO INSTALLATION
UPPER LEVEL HVAC

CONTRACTOR TO VERIFY LAYOUT PRIOR


ON PRELIMINARY FLOOR JOIST LAYOUT. HVAC
*NOTE: DUCT WORK FOR UPPER LEVEL HEATING BASED
W
W

W
C

C
C

W
Cold Air Return
Supply Register
HVAC Legend

ISSUE
NO. DATE DESCRIPTION

1/4" = 1'-0" 1 12-14-07 DESIGN REVIEW CASTLETON


PERMIT/PRICING
2 03-18-08 TIMBERFRAME
UPPER DOCUMENT

CONSTRUCTION
3 05-19-08 3-STALL
LEVEL HVAC DOCUMENT

4
LAYOUT LOT 2 CREEKSIDE RIDGE
5
A4.2 WILLISTON, NORTH DAKOTA
6 PLAN NO.: 07-064
Copyright © Homescape Design Group, 2008
WILLISTON, NORTH DAKOTA
LOT 2 CREEKSIDE RIDGE
CASTLETON
LINE OF JOISTS

TIMBERFRAME

PLAN NO.: 07-064


6'-9 1/2"
CENTER LINE OF STRUCTURAL BEAM

8'-8 1/2"

3-STALL
UPSET LVL BEAM
HEADER SIZE T.B.D.

HEADER

DROPPED LVL BEAM CONC. PATIO ABOVE

DESIGN REVIEW

CONSTRUCTION
PERMIT/PRICING
SIZE T.B.D.

DESCRIPTION

DOCUMENT

DOCUMENT
HEADER

ISSUE
DROPPED LVL BEAM
SIZE T.B.D.

05-19-08
03-18-08
12-14-07
DATE
1'-4" 1'-4"

NO.

6
3

5
2
1

Copyright © Homescape Design Group, 2008


BEGIN JOIST LAYOUT @
2 x 10 TREATED LEDGER THIS POINT & CONTINUE
@ 16" O.C.
TREATED 2 x 10 DECK JOISTS

SHADED AREA 6" DOWN


FROM M.L. SUBFLOOR TREATED BEAM
SIZE T.B.D.

MAIN LEVEL FLOOR JOIST LAYOUT


*NOTE: PRELIMINARY LAYOUT ONLY! CONFIRM WITH JOIST MANUFACTURER & LOCAL BUILDING CODES*

LINE OF JOISTS
6'-9 1/2"

CENTER LINE OF STRUCTURAL BEAM

8'-81/2"
8'-8 1/2"
UPSET LVL
BEAM SIZE T.B.D.

C/L OF
COLUMN

UPSET LAMINATED UPSET LVL


BEAM SIZE T.B.D. BEAM SIZE T.B.D.

HEADER

17'-31/2"
1'- 4" 1'-4"

FLOOR JOIST
LAYOUTS
13'-6 3/4" 16'-11 3/4"

BEGIN JOIST LAYOUT @


THIS POINT & CONTINUE
@ 16" O.C.

A5.1
1/4" = 1'-0"
UPPER LEVEL FLOOR JOIST LAYOUT
*NOTE: PRELIMINARY LAYOUT ONLY! CONFIRM WITH JOIST MANUFACTURER & LOCAL BUILDING CODES*
WILLISTON, NORTH DAKOTA
LOT 2 CREEKSIDE RIDGE
CASTLETON
TIMBERFRAME

PLAN NO.: 07-064


3-STALL
DESIGN REVIEW

CONSTRUCTION
PERMIT/PRICING
DESCRIPTION

DOCUMENT

DOCUMENT
ISSUE

05-19-08
03-18-08
12-14-07
DATE
HAND FRAME DOWN HAND FRAME DOWN
TO ROOF TO ROOF
START GARAGE TRUSS
LAYOUT HERE 1'-0" 14'-3 3/4"

NO.
1'-0"

6
3

5
2
@ 24" O.C.

1
1'-0"

Copyright © Homescape Design Group, 2008


1'-0"
B B

1'-0"
LINE OF TRUSS
B B
A

A
CENTER LINE OF STRUCTURAL TIMBER BEAM
1'-0"

B B

HI

P
HI
P
B B BEARING POINT ELEVATION

EY
A - TOP OF M.L. WALLS 109'-1 1/8 "

LL
B - TOP OF U.L. WALLS 118'-27/8 "
B B

VA

VA
LL
EY
B B

UPPER LEVEL BEARING WALLS

UPPER LEVEL BEARING WALLS


RIDGE
B B

RIDGE
RIDGE RIDGE

1'-6"
A

A
B B C/L OF
BEAM
RIDGE

B B

B B

B B RIDGE

12'-0"
V
A
Y B B

LL
E

EY
LL
A
V
P
HI

HI
B B

P
1'-0"

1'-0"

B B C/L OF
1'-0"

BEAM

1'-6"
1'-0"

14'-3 3/4"

DROP TRUSS FOR CLIPPED ROOF


1'-0"

1'-0"

1'-0" 11'-6" 1'-0"

ROOF TRUSS LAYOUT


*NOTE: PRELIMINARY LAYOUT ONLY! CONFIRM WITH TRUSS MANUFACTURER & LOCAL BUILDING CODES*

LAYOUT
TRUSS
ROOF

A5.2
1/4" = 1'-0"
WILLISTON, NORTH DAKOTA
LOT 2 CREEKSIDE RIDGE
CASTLETON
TIMBERFRAME

PLAN NO.: 07-064


SUMP L.L. FAMILY
CROCK
CL. ROOM
8' CEILING
CARPET FLOOR

3-STALL
16/0 x 17/0

GUEST
BEDROOM
8' CEILING GAMES
CARPET FLOOR
12/0 x 12/6
UP 14
RISERS

CL.

DESIGN REVIEW

CONSTRUCTION
PERMIT/PRICING
UNEXCAVATED

DESCRIPTION
8' CEILING

DOCUMENT

DOCUMENT
7' CEILING

ISSUE
W.H. FURNACE
FLOOR
DRAIN

05-19-08
03-18-08
12-14-07
DATE
U/C REF.

LINE OF SCREEN PORCH ABOVE


60" x 32"
MECHANICAL/ TUB/SHOWER

NO.

6
3

5
2
UNIT

1
STORAGE GAMES

Copyright © Homescape Design Group, 2008


8' CEILING

SINK.
7' CEILING
CONC. FLOOR BATH CARPET FLOOR
8' CEILING 16/0 x 7/0
TILE
FLOORING

LINE OF PORCH ABOVE

LOWER LEVEL DESIGN PLAN


892 sq ft finished

SEAT

36" x 72"
TUB
TILE
SHOWER

OWNER'S
OWNER'S RETREAT
BATH STEP CEILING
9' CEILING CARPET FLOOR
TILE FLOORING 13/6 x 13/6 GREAT
ROOM
9' CEILING
CARPET FLOOR
16/6 x 14/6
DN. 14
UP 16
RISERS
RISERS

9' CEILING
8' CEILING
OWNER'S
6" CURB

GARAGE CABINET
SLOPE FLOOR ABOVE STOOL CLOSET
9' CEILING
CARPET FLOOR

DW. ARCH
GALLERY
9' CEILING
UTILITY TILE FLOORING

LOWER & MAIN


LEVEL DESIGN
DISPLAY
FAMILY SCREEN

DRY
ENTRY/ DINING PORCH
RECEPTION

RANGE
9' CEILING 12/0 x 13/0
9' CEILING 1/2 BATH LAUNDRY KITCHEN WOOD FLOORING
12/0 x 11/6
WASH

TILE FLOORING 9' CEILING 9' CEILING 9' CEILING


TILE FLOORING TILE FLOORING WOOD FLOORING
13/6 x 10/0
D.W. SINK REF.

SEAT
CL.

PLAN
COVERED
PORCH

D1.1
1/4" = 1'-0"
MAIN LEVEL DESIGN PLAN
1,274 sq ft
WILLISTON, NORTH DAKOTA
LOT 2 CREEKSIDE RIDGE
CASTLETON
TIMBERFRAME

PLAN NO.: 07-064


3-STALL
DESIGN REVIEW

CONSTRUCTION
PERMIT/PRICING
DESCRIPTION

DOCUMENT

DOCUMENT
ISSUE

05-19-08
03-18-08
12-14-07
DATE
NO.

6
3

5
2
1

Copyright © Homescape Design Group, 2008


LINE OF M.L. WALLS BELOW LINE OF M.L. WALLS BELOW

LINE OF M.L. WALLS BELOW

BEDROOM #3
8' CEILING
CARPET FLOOR
11/0 x 12/6

DN. 16
RISERS

LIN.

CL. LINE OF SCREEN PORCH BELOW

SHARED
BATH BEDROOM #2
8' CEILING
8' CEILING
TILE FLOOR
CARPET FLOOR
10/6 x 12/6

CL.

60" x 32"
TUB/SHOWER
UNIT

UPPER LEVEL DESIGN PLAN


487 sq ft

DESIGN PLAN
UPPER LEVEL

D1.2
1/4" = 1'-0"
WILLISTON, NORTH DAKOTA
LOT 2 CREEKSIDE RIDGE
SUMP

CASTLETON
STEP
CROCK
Electrical Key

TIMBERFRAME

PLAN NO.: 07-064


4 Inch Recessed Can

6 Inch Recessed Can

STEP

3-STALL
Keyless

3
Light

3
Lamp

Ceiling Flush
Mount
FLOOR
SD PLUG Decorative Surface
Mount

Wall Mount
SD

DESIGN REVIEW

CONSTRUCTION
W.H.

PERMIT/PRICING
SD
FLOOR Fluorescent Cloud

DESCRIPTION
DRAIN

DOCUMENT

DOCUMENT
3

Outlet

ISSUE
C Outlet @ Countertop
Height

05-19-08
03-18-08
Bathroom Fan

12-14-07
DATE
C
Bathroom Fan/Light

NO.

6
3

5
2
C

1
Switch

Copyright © Homescape Design Group, 2008


SD Smoke Detector

FL. Under Cabinet Fluorescent

P/S Plug Strip

O.H.D. Opener w/ Light

Ceiling Fan

LOWER LEVEL ELECTRICAL PLAN


*NOTE: ELECTRICAL CONTRACTOR TO VERIFY
ALL FIXTURES, SWITCHES AND OUTLETS
PRIOR TO CONSTRUCTION.
*NOTE: VERIFY LAYOUT WITH FLOOR JOIST AND HVAC LAYOUTS

STEP

STEP
OUTLET ABOVE
MANTLE

STEP
STEP

3 3
C C

3
SD

FLOOR
SD PLUG

SD

3 3
WATERPROOF
3 OUTLET

LEVEL ELECTRICAL
CABINET

C
MOUNTED
3
OUTLET
3

C
FAN
W/ LIGHT

LOWER & MAIN


C

3 C C C 3

WATERPROOF
OUTLET

PLAN
MAIN LEVEL ELECTRICAL PLAN

1/4" = 1'-0"

E1.1
*NOTE: ELECTRICAL CONTRACTOR TO VERIFY
ALL FIXTURES, SWITCHES AND OUTLETS
PRIOR TO CONSTRUCTION.
*NOTE: VERIFY LAYOUT WITH FLOOR JOIST AND HVAC LAYOUTS
WILLISTON, NORTH DAKOTA
LOT 2 CREEKSIDE RIDGE
CASTLETON
TIMBERFRAME

PLAN NO.: 07-064


3-STALL
DESIGN REVIEW

CONSTRUCTION
PERMIT/PRICING
DESCRIPTION

DOCUMENT

DOCUMENT
ISSUE

05-19-08
03-18-08
12-14-07
DATE
NO.

6
3

5
2
1

Copyright © Homescape Design Group, 2008


STEP

STEP
Electrical Key

4 Inch Recessed Can

STEP

STEP
6 Inch Recessed Can

Keyless
Light

3
Lamp

Ceiling Flush
SD SD Mount
Decorative Surface
Mount

3
SD
Wall Mount

C
Fluorescent Cloud

Outlet

C Outlet @ Countertop
3 Height

Bathroom Fan

Bathroom Fan/Light

Switch

SD Smoke Detector

FL. Under Cabinet Fluorescent

P/S Plug Strip

O.H.D. Opener w/ Light

Ceiling Fan

UPPER LEVEL ELECTRICAL PLAN


*NOTE: ELECTRICAL CONTRACTOR TO VERIFY
ALL FIXTURES, SWITCHES AND OUTLETS
PRIOR TO CONSTRUCTION.
*NOTE: VERIFY LAYOUT WITH ROOF TRUSS LAYOUT

UPPER LEVEL
ELECTRICAL
PLAN E1.2
1/4" = 1'-0"

Das könnte Ihnen auch gefallen