Sie sind auf Seite 1von 84

KYORITSU GLOBAL NETWORK

Test and Measuring Instruments Catalogue 2009

Catalogue 2009
Japan

Italy
U.K.
U.S.A.
China

Thailand

Headquarters
Affiliates

● KYORITSU ELECTRICAL ● Kew (Thailand) Ltd. ● Kewtech Corporation Ltd.


INSTRUMENTS WORKS, LTD. Navanakorn Industrial Estate60/48, Moo 19, Midas House, Unit 2b Stones Courtyard,
No.5-20, Nakane 2-chome, Klongluang,Pathumthani, 12120 Thailand High Street, Chesham, Buckinghamshire,
Meguro-ku, Tokyo, 152-0031 Japan Phone: 66-2-529-0542~4 HP5 1DE, England
Phone: 81-3-3723-0131 FAX: 66-2-529-0541 Phone: 44-1494-792212
FAX: 81-3-3723-0152 FAX: 44-1494-791826
URL:http://www.kew-ltd.co.jp
E-mail: info@kew-ltd.co.jp
Factory: Ehime

● Kew Europe Office ● Kyoritsu America, LLC ● KYORITSU SHANGHAI


Viale Rimembranze 93/18, 4175 Veterans Memorial Highway, TRADING COMPANY LIMITED
20099 Sesto S. Giovanni (MI) Italy Suite 400, Ronkonkoma, NY, 11779, U.S.A. Room241, 2nd Floor, No.12 Waitan Building,
Phone: 39- 02- 38238685 Phone: 1-631-676-7566 No.12 Zhongshan Dong Yi Road,
FAX: 1-631-676-7563 Huangpu District, Shanghai P.C.200002 China
Phone: 86-21-6321-8899
FAX: 86-21-6339-2868

Please read the "Safety Warnings" in the instruction manual supplied with the instrument thoroughly and completely
Safety Warnings : for correct use. Failure to follow the safety rules can cause fire, trouble, electrical shock, etc. Therefore, make sure
to operate the instrument on a correct power supply and voltage rating marked on each instrument.

For inquires or orders :

In consideration of the environment, soy ink and recycled paper were used in this publication. The contents of this leaflet are subject to change without notice. GeneCata09-1E Sep. 08 AD
Greetings
The electrical instrumentation industry has been playing a key role as a basis for
technological development to sustain the growth of the world.
With the passage of time there is an ever increasing need for us to meet the more
diversified and sophisticated demand from all walks of our industrial society.
Since its foundation in 1940 Kyoritsu Electrical Instruments Works, Ltd. has been pursuing
a solid business philosophy of "Customer First" in every area of our production and
servicing activities, thus establishing a relationship of mutual trust with our customers.
Here in our company all of us are expected to fully develop our individual personality
and creativity into a valuable corporate asset for our future growth.
We are united together by the guiding principle of always being diligent, honest and
appreciative of all those around us.
We sincerely wish that with this corporate culture we can make some contribution
towards building a more affluent human society.
Thank you in advance for all your continuous support and patronage.

ISO9001
QUALITY STANDARDS APPROVAL
(Headquarters・Ehime Factory)

Ehime Factory of Kyoritsu Electrical Instruments Works, Ltd. obtained ISO 9001 certification in
December, 1992.
The certification was given by Bureau Veritas which is one of the globally recognized
certification bodies.
C O N T E N T S
ANALOGUE MULTIMETERS 1106, 1109, 1110...................................................... 6
1009, 1011, 1012...................................................... 7
1018, 1018H, 1030................................................... 8
DIGITAL MULTIMETERS 1061, 1062................................................................ 9
2000, 2001..............................................................11
VOLTAGE TESTER 1700,1710............................................................... 10
FORK CURRENT TESTERS 2300R......................................................................11
ANALOGUE CLAMP METERS 2608A, 2805.......................................................... 12
2002PA, 2002R, 2006, 2007A.............................. 13
2017, 2027, 2031.................................................... 14
2040........................................................................ 15
DIGITAL CLAMP METERS 2003A, 2004, 2009A.............................................16
2010, 2033, 2037...................................................17
2046R, 2055, 2056R............................................. 18
2412, 2413F, 2413R................................................ 19
LEAKAGE CLAMP METERS 2417, 2431, 2432................................................... 20
2433, 2433R, 2434................................................ 21
MULTI-TRANS, CLAMP ADAPTOR 8004, 8008, 8006.................................................. 24
CLAMP ADAPTORS 8112, 8112BNC, 8113............................................. 25
3001B, 3005A, 3007A........................................... 26
DIGITAL INSULATION/CONTINUITY TESTERS 3021, 3022, 3023.................................................. 27
3111V, 3131A.......................................................... 28
ANALOGUE INSULATION/CONTINUITY TESTERS 3132A...................................................................... 29
3144A, 3145A, 3146A, 3161A.............................. 29
ANALOGUE INSULATION TESTERS 3165, 3166, 3315, 3316......................................... 30
3321A, 3322A, 3323A...........................................31
3121, 3122, 3123, 3124......................................... 33
HIGH VOLTAGE INSULATION TESTERS 3125........................................................................ 34
3128........................................................................ 35
4102A..................................................................... 37
EARTH TESTERS 4105A..................................................................... 38
4106........................................................................ 39
EARTH CLAMP TESTER 4200........................................................................ 40
4116A, 4118A......................................................... 41
LOOP/PSC TESTERS 4120A...................................................................... 42
5402D, 5406A........................................................ 43
RCD TESTERS 5410........................................................................ 44
5000, 5001............................................................. 45
LOGGERS 5010, 5020............................................................. 47
6010A..................................................................... 50
6010B...................................................................... 51
6011A...................................................................... 52
MULTI FUNCTION TESTERS 6016........................................................................ 53
6017, 6018.............................................................. 55
6020, 6030............................................................. 56
6050........................................................................ 57
PORTABLE APPLIANCE TESTERS 6200, 6201A, 6202............................................... 58
6300........................................................................ 59
POWER METERS 6310.........................................................................61
5201, 5202............................................................. 65
5500, 5510............................................................. 66
OTHERS 8030, 8031,8131F.................................................. 67
Demonstration Panels............................................... 68
8124, 8125, 8126, 8127, 8128, 8129..................... 69
SENSORS 8121, 8122, 8123, 8146, 8147, 8148..................... 70
8141, 8142, 8143, 8309, 8325F............................ 71
ACCESSORIES Test Leads................................................................. 73
Instrument Glossary................................................. 78
Kyoritsu Quality Control Concept............................ 80
PRODUCT INDEX..................................................... 81

Safety Warnings
Please read the “Safety Warnings” in the instruction manual supplied with the instrument thoroughly and completely for
safety use. Failure to follow the safety rules can cause fire, trouble, electrical shock, etc. Therefore, make sure to operate the
instrument on a correct power supply and voltage rating marked on each instrument.
K YO R I T S U L I N E U P
ANALOGUE MULTIMETERS DIGITAL MULTIMETERS
MODEL 1106 MODEL 1109 MODEL 1110 MODEL 1009 KEW 1011/1012 KEW 1018/1018H KEW 1030 KEW 1061/1062
P6 P6 P6 P7 P7 P8 P8 P9

UÊ £ä£Ó

DIGITAL CLAMP METERS RMS

MODEL 2006 MODEL 2007A MODEL 2017 MODEL 2027 MODEL 2031 KEW 2040
P13 P13 P14 P14 P14 P15

φ33 MAX
AC 600A

φ19 MAX
AC 200A AC V DC V

AC V DC V φ33 MAX
AC 600A
φ33 MAX
AC 600A
φ33 MAX
AC 600A Hz
RMS
Continuity AC V Continuity AC V Continuity AC V Continuity φ24 MAX
AC 200A Continuity
#!4Ⅳ
6

DIGITAL CLAMP METERS LEAKAGE CLAMP METERS


KEW 2046R KEW 2055/2056R MODEL 2412 MODEL 2413F MODEL 2417 MODEL 2431
KEW 2413R
P18 P18 P19 P19 P20 P20
ÓäxÈ,

φ33 UÊ ÓäxÈ,

-!8
AC V c
UÊ ÓäxÈ, φ40 Ó{£Î,

!#$#!
RMS
DC V φ40 MAX
AC/DC 1000A AC V MAX
AC 500A
Resolution
0.01mA
φ68

Hz °C DC V Hz AC V MAX
AC1000A
Resolution
0.1mA
φ40 MAX
AC 500A
φ24 MAX
AC 200A
Continuity
RMS
#!4Ⅳ OUT External OUT PEAK Resolution Resolution
#!4Ⅳ
Continuity 6 PUT Filter Power Supply PUT 10/100ms Filter 0.1mA Filter WP 0.01mA Filter
6

DIGITAL INSULATION/CONTINUITY TESTERS ANALOGUE INSULATION/CONTINUITY TESTERS ANALOGUE


KEW 3021 3023 3111V 3131A 3132A 3144A~3161A 3165/3166
~ MODEL MODEL MODEL MODEL MODEL

P27 P28 P28 P29 P29 P30

3021(125V/250V/500V/
1000V)3022(50V/100V/250V/ 3144A(250V/500V) 3146A(50V/125V) 3165(500V)
500V)3023(100V/250V/500V/1000V) 3111V(250V/500V/1000V) 3131A(250V/500V/1000V) 3132A(250V/500V/1000V) 3145A(125V/250V) 3161A(15V/500V) 3166(1000V)

EARTH TESTERS EARTH CLAMP TESTER LOOP/PSC TESTERS RCD


MODEL 4102A MODEL 4105A KEW 4106 MODEL 4200 MODEL 4116A/4118A MODEL 4120A MODEL 5402D
P37 P38 P39 P40 P41 P42 P43

MULTI FUNCTION TESTERS RMS


PORTABLE APPLIANCE TESTERS POWER
KEW 6016 MODEL 6017/6018 MODEL 6020/6030 MODEL 6050 (LOOP+RCD) MODEL 6200/6202 KEW 6201A MODEL 6300
P53 P55 P56 P57 P58 P58 P59

RMS
VOLTAGE TESTERS DIGITAL MULTIMETERS FORK CURRENT TESTER ANALOGUE CLAMP METERS DIGITAL CLAMP METERS
KEW 1700 MODEL 2000 φ6 MAX
AC/DC 60A MODEL 2300R MODEL 2608A MODEL 2805 MODEL 2002PA
KEW 1710 MODEL 2001 φ10 MAX
AC/DC 100A MODEL 2002R
P11 P11 P12 P12 P13

2002R
P10

AC V φ33 φ55 MAX


AC2000A

DC V MAX
AC 300A °C φ35 MAX
AC 600A AC V DC V

Continuity Hz φ10 MAX


AC/DC 100A AC V DC V AC V PEAK
10ms
OUT
PUT Continuity
RMS

DIGITAL CLAMP METERS


KEW 2003A MODEL 2004 MODEL 2009A MODEL 2010 MODEL 2033 MODEL 2037
P16 P16 P16 P17 P17

φ55 φ55 P17 PEAK


DC200ms
AC500ms Continuity
RMS
MAX
AC/DC 2000A AC V MAX
AC/DC 2000AAC V φ33 MAX
AC 600A
MAX
DC1000A
RMS
DC V Continuity φ19 MAX
AC/DC 200A DC V Hz φ7.5 MAX
AC/DC 20A AC V DC V
OUT
PUT
MAX
HOLD
#!4Ⅳ
6 AC V DC V Continuity
OUT
PUT
PEAK
10ms
OUT
PUT
External
Power Supply
φ24 MAX
AC/DC 300A Hz AVG LoHz

DIGITAL INSULATION/CONTINUITY TESTERS


MODEL 2432 MODEL 2433 MODEL 2434 MODEL 3001B MODEL 3005A MODEL 3007A
MODEL 2433R
P26 P26 P26
P20 P21 P21

2433R

φ40 MAX
AC 100A
φ40 MAX
AC 400A
φ28 MAX
AC 100A

Resolution PEAK Resolution PEAK Resolution


0.001mA Filter 10ms 0.01mA Filter 10ms 0.1mA Filter
3001B(500V/1000V) 3005A(250V/500V/1000V) 3007A(250V/500V/1000V)

INSULATION TESTERS HIGH VOLTAGE INSULATION TESTERS


MODEL 3315/3316 MODEL 3321A~3323A MODEL 3121~3123 MODEL 3124 MODEL 3125 KEW 3128
P30 P31 P33 P33 P34 P35

3315(125V/250V/500V/1000V) 3321A(250V/500V/1000) 3322A(125V/ 3121(2500V) 3122(5000V)


3316(50V/125V/250V/500V) 250V/500V) 3323A(25V/50V/100V) 3123(5000V/10000V) 3124(1k~10kV Variable) 3125(500/1000/2500/5000V) 3128(500/1000/2500/5000/10000/12000V)

TESTERS LOGGERS MULTI FUNCTION TESTERS


MODEL 5406A KEW 5410 MODEL 5000 KEW 5010 MODEL 6010A KEW 6010B MODEL 6011A
MODEL 5001 KEW 5020
P43 P44 P50 P51 P52
P45 P47

METERS RMS RMS


OTHERS
KEW 6310 MODEL 5201 MODEL 5202 MODEL 5500 MODEL 5510 MODEL 8030 MODEL 8031 KEW 8031F
P61 P65 P65 P66 P66
P67 P67 P67

RMS
KEW ANALOGUE MULTIMETERS
MODEL 1106

MODEL 1106 DC V

AC V
0.5/5/25/100/250/500V(5kΩ/V)
±3% of FS
10/50/250/500V(2.5kΩ/V)
±3% of FS
DC A 200µA/2.5/25/250mA
±3% of FS
±5% of FS(250mA)
Ω 3/30/300kΩ
±3% of scale length
Battery test 2V(20Ω load)
Temperature -20°C~+150°C
±5°C(0°C~+100°C) ±10°C(other ranges)
(with the use of Temperature probe 7060)
Withstand voltage 3000V AC for 1 minute
Power source R6P(AA)(1.5V) × 1
Dimensions 130(L) × 85(W) × 38(D)mm
Weight 175g approx.
• Fuse and diode protect circuit.
Accessories 7066(Test leads) 8901(Fuse[0.5A/250V]) × 1
• Safety designed input terminals and
R6P(AA) × 1 Instruction manual
test leads.
Optional 9059(Carrying case)
7060(Temperature probe)

1109
MODEL 1109

DC V 0.1/0.5/2.5/10/50/250/1000V
MODEL ±3% of FS (20kΩ/V)
AC V 10/50/250/1000V(9kΩ/V)
±3% of FS
DC A 50µA/2.5/25/250mA
±3% of FS
AC A 15A
±3% of FS
Ω 2/20kΩ/2/20MΩ
±3% of scale length
Decibel -10~+62dB
hFE 0~1000(Ω× 10)
• Mirrored scale for easy and ac- ±3% of scale length
curate reading. Withstand voltage 6000V AC for 1 minute
• Fuse and diode protect circuit Power source R6P(AA)(1.5V) × 2 6F22(9V) × 1
(except 15A AC range). Dimensions 150(L) × 100(W) × 47(D)mm
• Output terminal to cut off DC Weight 330g approx.
MODEL

component when measuring Accessories 7085(Test leads) 8901(Fuse[0.5A/250V]) × 2


AC voltage. R6P(AA) × 2 6F22 × 1
• Safety designed input terminals Instruction manual
1106

and test leads. Optional 9076(Carrying case)

1110
MODEL 1110

DC V 0.3V(16.7kΩ/V) ±3% of FS
MODEL 3/12/30/120/300/600V(20kΩ/V)
±3% of FS
AC V 12V(9kΩ/V) ±4% of FS
30/120/300/600V(9kΩ/V)
±3% of FS
MODEL

DC A 60µA/30/300mA
±3% of FS
Ω 3/30/300kΩ
1109

±3% of scale length


Continuity buzzer Buzzer sounds below 100Ω
Battery Test 1.5V(0.7~2V)
±3% of FS (10Ω load)
Temperature -20°C~+150°C
±3% of scale length(0°C~+100°C)
±4% of scale length(other ranges)
(with the use of Temperature probe 7060)
LED 10mA approx. at 0Ω
(at 3V of battery voltage)
Maximum 600V AC/DC (between line/neutral)
MODEL

circuit voltage 300V AC/DC (against earth)


• High sensitivity DC20kW/V. Withstand voltage 3700V AC for 1 minute
• Polarity selector switch. Applicable IEC 61010-1 CAT.3 300V Pollution degree 2
1110

• 1m drop-proof heavy duty designed taut-band movement. standard CAT.2 600V Pollution degree 2
• Can measure line voltage up to AC 600V. IEC 61010-031, IEC 61326-1
(Voltage to ground MAX AC300V) (Protected by 600V ceramic fuse Power source R6P(AA)(1.5V) × 2
against accidental overload) Dimensions 94(L) × 140(W) × 39(D)mm
• Continuity buzzer, battery check, LED check, temperature measurement Weight 280g approx.
function. Accessories 7066(Test leads) 8923(Fuse[F500mA/600V]) × 2
• Skeleton type robust and clear case with carrying handle furnished as R6P(AA) × 2 9103(Carrying case) Instruction manual
standard accessory. Optional 7060(Temperature probe)
6 FS : full scale
KEW DIGITAL MULTIMETERS
1009
MODEL 1009

DC V 400mV/4/40/400/600V(Input impedance 10MΩ)


MODEL ±0.6%rdg±4dgt(400mV/4/40/400V) ±1.0%rdg±4dgt(600V)
AC V 400mV/4/40/400/600V(Input impedance 10MΩ)
±1.6%rdg±4dgt(20~400mV) ±1.3%rdg±4dgt(4/40V) ±1.6%rdg±4dgt(400/600V)
DC A 400/4000µA/40/400mA/4/10A ±2.0%rdg±4dgt(400/4000µA)
±1.0%rdg±4dgt(40/400mA) ±1.6%rdg±4dgt(4/10A)
• Display : 4000 counts. AC A 400/4000µA/40/400mA/4/10A
• Auto range and manual range selec- ±2.6%rdg±4dgt(400/4000µA) ±2.0%rdg±4dgt(40/400mA/4/10A)
tor provided. (with range hold fea- Ω 400Ω/4/40/400kΩ/4/40MΩ
ture) ±1.0%rdg±4dgt(400Ω/4/40/400kΩ/4MΩ) ±2.0%rdg±4dgt(40MΩ)
• Diode test feature. Continuity buzzer 400Ω(Buzzer sounds below 70Ω)
• Capacitance test feature. Diode test 1.5V Release Voltage : Approx. 0.4mA test current
• Relative measurement. Capacitance test 40nF/400nF/4µF/40µF/100µF
• Resistance range provides audible Frequency 5.12/51.2/512Hz/5.12/51.2/512kHz/5.12/10MHz
(Input sensitivity
continuity test. Current:more than 200µA[~10kHz] Voltage:more than 1.5V[~10kHz]
• Automatically turns power off in Hz:more than 1.5V[~1MHz]、 2V[>1MHz])
about 30 minutes to conserve battery DUTY 0.1~99.9%(Pulse width/Pulse period) ±2.5%±5dgt
life. Withstand voltage 3700V AC for 1 minute
• Direct current measurement up to Applicable standards IEC 61010-1 CAT.3 300V IEC 61010-031 IEC 61326-1
10A AC and DC. Power source R6P(1.5V) × 2 (Auto power off : approx. 30 minutes)
• With Holster. Dimensions 155(L) × 75(W) × 33(D)mm
• Designed to international safety stan- Weight 260g approx.
dard IEC61010-1 CAT.3 300V. Accessories KTL04(Test leads) 8924(Fuse[0.5A/250V] ) × 1
8925(Fuse[10A/250V]) × 1 R6P × 2 Instruction manual

KEW 1011/1012
KEW 1012 KEW 1011
£ä£Ó

DC V 600.0mV/6.000/60.00/600.0/600V
(Input impedance :10MΩ, 100MΩ only 600mV)
±0.5%±2dgt(600.0mV/6.000/60.00/600.0V) ±0.8%±3dgt(600V)
AC V 6.000/60.00/600.0/600V 6.000/60.00/600.0/600V
(Input impedance :10MΩ) (Input impedance :10MΩ)
±1.5%±5dgt(6.000V) ±1.0%±3dgt(6.000/60.00/600.0V)
±1.2%±3dgt(60.00/600.0V) ±1.5%±3dgt(600V)
±1.5%±5dgt(600V)
DC A 600/6000μA/60/600mA/6/10A
±1.2%±3dgt(600/6000μA/60/600mA) ±2.0%±5dgt(6/10A)
AC A 600/6000μA/60/600mA/6/10A

1009
±1.5%±4dgt(600/6000μA/60/600mA) ±2.2%±5dgt(6/10A)
Ω 600Ω/6/60/600kΩ/6/60MΩ
±1.0%±2dgt(600Ω/6/60/600kΩ/6MΩ) ±2.0%±3dgt(60MΩ)
Continuity buzzer 0~600Ω(Buzzer sounds below 100Ω)

MODEL
Diode test 2.8V release voltage : Approx. 0.4mA test current
photo : 1012 Capacitance test 40/400nF/4/40/400/4000μF
Frequency 10/100/1000Hz/10/100/1000kHz/10MHz
(Input sensitivity
Current:more than 800μA[~10kHz] Voltage:more than 1.5V[~10kHz]
•6040 counts with Bar Graph display Hz:more than 0.4V[~10kHz])
•MIN/MAX function enables to record min & max value DUTY 0.1~99.9%(Pulse width/Pulse period) ±2.0%±2dgt(~10kHz)
•REL(relative value) function to indicate the measurement variation Temperature -50~300°C(-58~572°F)
Saving the initial value at the start of measurement as a reference value(= zero) (with the use of Temperature

1011/1012
The difference between the later measured values and the reference value is indi- probe 8216)
cated on the display Withstand voltage AC3700V / 1min.
• Temperature measurement, selectable for °C and °F (KEW 1011) Applicable IEC 61010-1 CAT.3 300V Pollution degree 2
supplied with K-type temperature probe (8216): -50~300 °C (-58~572°F) standards CAT.2 600V Pollution degree 2
• True RMS can measure and indicate distorted waveforms (KEW 1012) IEC 61010-031 IEC 61326
•DUTY function Power source R6P(1.5V) × 2 (Auto power off : approx. 15 minutes)
(It is possible to measure Pulse width / Pulse period) Dimensions 161(L) × 82(W) × 50(D)mm
•Data Hold function, Auto Power Off function
KEW

Weight Approx. 280g


•Continuity with buzzer and Diode Check function Accessories KTL04(Test leads)
•Capacity measurement of capacitors 8216(K-type temperature probe)(1011 Only)
•Current ranges are protected by fuses (600V ceramic) 8918(Ceramic fuse[0.8A/600V]) × 1 built-in
•Designed to meet international safety standards 8919(Ceramic fuse[10A/600V]) × 1 built-in
IEC61010-1 CAT.3 300V / CAT.2 600V R6P × 2 Instruction manual

Accessories

KTL04 MODEL 8216


Test leads Temperature probe
Range:-50~300°C (-58~572°F)
Note : KEW1011 can measure max. 700ºC
In order to measure over 300°C, please use a
K-type temperature probe available in the market.

7
KEW DIGITAL MULTIMETERS
KEW 1018 (Soft case type)/1018H (Hard case type)
KEW 1018/1018H

DC V 400mV/4/40/400/600V(Input impedance 10MΩ)


±0.8%rdg±5dgt(400mV/4/40/400V)
±1.0%rdg±5dgt(600V)
AC V 4/40/400/600V(Input impedance 10MΩ)
±1.3%rdg±5dgt(4/40V)
±1.6%rdg±5dgt(400/600V)
Ω 400Ω/4/40/400kΩ/4/40MΩ
±1.0%rdg±5dgt(400Ω/4/40/400kΩ/4MΩ)
±2.5%rdg±5dgt(40MΩ)
Continuity buzzer 400Ω(Buzzer sounds below 120Ω)
Diode test 4V release voltage : Approx. 0.4mA test current
Capacitance test 4nF/40nF/400nF/4µF/40µF/200µF
Frequency 10/100Hz/1/10kHz (Input sensitivity Voltage:more than 1.5V)
Duty 0.1~99.9% ±2.5%rdg±5dgt(Pulse width/Pulse cycle)
Withstand voltage 3700V AC for 1 minute
Applicable standards IEC 61010-1 CAT.3 300V IEC 61010-031 IEC 61326-1
Power source LR44(1.5V) × 2 (Auto power off : approx. 15 minutes)
Dimensions 107(L) × 54(W) × 10(D)mm
Weight 70g approx.
Accessories LR44× 2 Instruction manual
9115(Carrying case[Soft]) 9114(Carrying case[Hard])

• Display : 4000 counts.


• Auto range.
• Diode test feature.
• Capacitance test feature.
• Continuity test.
• Automatically turns power off in about 15 minutes to conserve battery life.
sSoft case type sHard case type • Designed to international safety standard IEC61010-1 CAT.3 300V.

KEW 1030
KEW

KEW 1030
1018/1018H

DC V 400m/4/40/400/600V(5 range auto)


±0.8%rdg±5dgt(400mV~400V)
±1.0%rdg±5dgt(600V)
AC V 4/40/400/600V(4 range auto)
±1.3%rdg±5dgt(4/40V)(50/60Hz)
±1.6%rdg±5dgt(400/600V) (50/60Hz)
Ω 400/4k/40k/400k/4M/40MΩ(6 range auto)
±1.0%rdg±5dgt(400Ω~4MΩ)
±2.5%rdg±5dgt(40MΩ)
Continuity buzzer Buzzer sounds when resistance is 120Ω or less.
Diode test Test voltage approx. 0.3~1.5V
Capacitance test 50n/500n/5µ /50µ /100µ F(5 range auto)
±3.5%rdg±10dgt(50nF) ±3.5%rdg±5dgt(500n~50µ F)
±4.5%rdg±5dgt(100µ F)
• Compact in Size, Light in Weight and Simple in Use
KEW

Frequency 5/50/500/5k/50k/200kHz
• Double moulding provides comfortable and good feeling in hand ±0.1%rdg±5dgt
1030

• Penlight illuminates brightly the point to be measured, even in dark place (Input sensitivity
• Backlight LCD is highly visible, even in darkness Voltage:more than 1.5V[~50kHz] Voltage:more than 10V[>200kHz])

• Auto power-off function saves the battery life Duty 0.1~99.9% ±2.5%rdg±5dgt (Pulse width / Pulse cycle)
• Unique wrapping mechanism for test lead in the rear side compartment Data hold The measured value can be hold by pressing Data hold button
• Unique protection mechanism for the test prod for safety Battery voltage warning When the battery voltage drops to 2.4V±0.2V or less
• All ranges including Ohm range are protected against overload voltage of 600V Applicable standards IEC 61010-1 CAT.3 600V
• Designed in confor mity wit h Int er national safety s t andards IEC 61010-031 IEC 61326-1(EMC)
IEC61010-1:2001 CAT.3 600V Power source Button type battery LR44(SR44)(1.5V) × 2 (Auto power off : approx. 30 minutes)
Dimensions 190(L) × 39(W) × 31(D)mm
Weight Approx. 100g (including batteries)
Accessories 9130(Carrying case) LR44(1.5V) × 2 Instruction manual

8
KEW DIGITAL MULTIMETERS
KEW 1061 (Professional model)/1062 (Top of the range Professional model)
High Accuracy, High Performance and Reliable Measurements.
• 0.02% basic DC accuracy
• Large display with 50,000 counts
• Dual display for double indication for AC and DC, V and Hz, etc.
RMS • True-RMS Measurements AC and AC+DC
• Wide AC Frequency bandwidth from 10Hz~100kHz.*
• True-RMS or MEAN value detection mode can be selected.*
• Fast Peak Hold response time of 250μs.*
• Low-pass filter for motor drive measurements.*
• Low Power W for measuring the resistance of parts on PCB under low
measurement current.*
• User calibration function.
Safety design for industrial use.
• Complies with IEC 61010-1 CAT.31000V, CAT.4 600V
• Terminal shutter to prevent incorrect test leads’ insertion in current terminals.
• Very wide operating temperature range from -20~+55°C
Reliable support for data management.
• Large data logging memory
• KEW 1062 : 10,000 data
• KEW 1061 : 1,000 data
• Download data and Live Monitoring on a PC via the USB interface.
photo : 1062
(Option for USB Communication set) *Only for KEW 1062

KEW 1061 KEW 1062


Detection mode RMS MEAN/RMS (switch)
50.000/500.00/2400.0mV/5.0000/50.000/500.00/1000.0V
DC V (Input impedance: Approx. 100MW[50/500/2400mV], 10MW[5/50/500/1000V])
±0.02%rdg±2dgt (Basic accuracy)
50.000/500.00mV/5.0000/50.000/500.00/1000.0V
AC V [RMS] (Input impedance: 11MW<50pF[50/500mV/5V], 10MW<50pF[50/500/1000V])
±0.7%rdg±30dgt (Basic accuracy) ±2%rdg±50dgt (Basic accuracy)
50.000/500.00mV/5.0000/50.000/500.00/1000.0V
AC V [MEAN]* - (Input impedance: 11MW<50pF[50/500mV/5V], 10MW<50pF[50/500/1000V])
±1%rdg±30dgt (Basic accuracy)
5.0000/50.000/500.00/1000.0V (Input impedance: 11MW<50pF[5V], 10MW<50pF[50/500/1000V])
DCV+ACV
±1%rdg±10dgt (Basic accuracy) ±0.5%rdg±10dgt (Basic accuracy)
DC A 500.00/5000.0μA/50.000/500.00mA/5.0000/10.000A ±0.2%rdg±5dgt (Basic accuracy)
500.00/5000.0μA/50.000/500.00mA/5.0000/10.000A
DC A [RMS]
±1%rdg±20dgt (Basic accuracy) ±0.75%rdg±20dgt (Basic accuracy)

1061
500.00/5000.0μA/50/500mA/5/10A
DC A [MEAN]* -
±1.5%rdg±20dgt (Basic accuracy)
500.00/5000.0μA/50.000/500.00mA/5.0000/10.000A
DCA+ACA
±1.5%rdg±10dgt (Basic accuracy) ±1%rdg±10dgt (Basic accuracy)

KEW
500.00W/5.0000/50.000/500.00kW/5.0000/50.000MW
W
±0.1%rdg±2dgt (Basic accuracy) ±0.05%rdg±2dgt (Basic accuracy)
5.000/50.00/500.0kW/5.000MW
LowPower-W* -
±0.2%rdg±3dgt (Basic accuracy)
Continuity buzzer 500.0W (The buzzer turns on for resistances lower than 100±50W.)
Diode test 2.4000V ±1%rdg±2dgt Open-loop voltage:<1.5V(Approx. 0.5mA Measuring Current)
5.000/50.00/500.0nF/5.000/50.00/500.0μF/5.000/50.00mF
Capacitance
±1%rdg±5dgt
2.000~9.999/9.00~99.99/90.0~999.9/0.900~9.999/9.00~99.99Hz
Frequency
±0.02%rdg±1dgt (Basic accuracy) 1062
DUTY 10~90% ±1%rdg
Temperature -200~1372°C ±1%rdg±1.5°C(with the use of K-type Temperature probe)
DC Voltage, AC Voltage, DC Current, AC Current, Resistance, Frequency, Temperature, Capacitor, Duty cycle ratio, Decibel (dBV, dBm),
Measurement functions
Continuity Check, Diode Test, LowPower-W*
KEW

Data Hold (D•H), Auto Hold (A•H), Peak Hold* (P•H), Range Hold (R•H), Maximum value (MAX), Minimum value (MIN), Average value (AVG),
Other functions
Zero Adjustment (Capacitor, Resistance), Relative values, Save to Memory, LCD backlight
Withstand voltage 6,880V/5 sec.
Application standards IEC 61010-1 CAT.4 600V, CAT.3 1000V Pollution degree 2, IEC 61010-031, IEC 61326-1(EMC)
Power source R6(1.5V)×4 (Auto power off: approx. 20 minutes)
Dimensions/Weight 192(L)×90(W)×49(D)mm / Approx. 560g (including batteries)
Accessories 7220(Test leads), R6×4, Instruction manual, 8926(Fuse[440mA/1000V])×1 (included), 8927(Fuse[10A/1000V])×1 (included)
*Only for KEW 1062

Optional
Description MODEL Specification Description MODEL Specification
USB Communication set 8241 USB adaptor+USB cable+DMM Software Max. 500°C (Surface type, Point material:
8405
DMM Printer full set 8249 8243+8246+8248 Ceramic)
Printer Communication set 8243 Printer Adapter +RS232 cable Temperature probes 8406 Max. 500°C (Surface type)
Printer 8246 Printer + Thermal paper(1 roll) 8407 Max. 700°C (Liquid, Semi-solid)
AC adapter for printer[EU] 8248 AC230V±10% 8408 Max. 600°C (Air, Gas)
Thermal paper for printer 8247 10 rolls For the main unit with test leads and
Carrying case 9150
communication cable

9
KEW VOLTAGE TESTERS
1700/1710
KEW 1700/1710

Voltage test
KEW Voltage range 12~690V AC/DC
LED
Nominal voltage 12/24/50/120/230/400/690V
Probe Protection AC(45~400Hz), DC (±)
Cover Tolerance Light on at more than :
(Threshold voltage) 7±3V(12V LED)
18±3V(24V LED)
37.5±4V(50V LED)
75%±5% of nominal voltage
(120/230/400/690V LED)
Response time < 0.5s at 100% of each nominal voltage
LCD(1710 only)
Range / Resolution 300V(7.0~299.9V)/ 0.1V
(Auto-range) 690V(270~759)/ 1V
Accuracy(23±5˚C) ±1.5V(7~100V)
±1%±5dgt(100~690V)
AC(45~400Hz), DC(±)
Overrange indication “OL”
Also available Responce time < 2s at 90% of each voltage
non LCD model KEW 1700. Peak current Is<3.5mA(at 690V)
Measurement duty 30s ON(operation time)
240s OFF(recovery time)
• Designed to meet international safety Internal battery consumption Approx. 33mA(battery 3V,measuring 690V AC)
standards IEC 61243-3 / IEC 61010-1 Battery life Approx. 2500 operations(30s ON/240s OFF duty)
Measurement Category (CAT.) 4 600V Single-pole phase test
• Self-Diagnostic test Voltage range 100~690V AC (45~100Hz)
• AC and DC voltage tests up to 690V 180~690V AC (100~400Hz)
with LEDs and LCD Phase rotation test
• Polarity indication System Three-phase 4-wire system
• Single-pole phase test 200~690V phase-to-phase
• Phase rotation test (100~400V earth-to-phase)
• Double molding gives comfortable grip AC 50/60Hz
• Continuity test Phase range 120±5 degree
• Auto-power ON / OFF Continuity test
• Pen light for illuminating measurement Detection range 0~400kΩ+50%
points Test current Approx. 1.5µ A (battery 3V, 0Ω)
• Variable distance in socket, 16.7mm or Internal battery consumption Approx. 30mA (battery 3V, 0Ω)
19.0mm Operating temperature -10∼55°C, max 85% RH (no condensation)
KEW

• Variable probe Tips, 1.6mm or 4mmf and humidity ranges


• Probe cover protects user and probe Tips Storage temperature -20∼60°C, max 85% RH (no condensation)
1700/1710

• IP65 (IEC 60529) and humidity ranges


Applicable standards IEC 61010-1 CAT.3 / 4 600V
IEC 61243-3 CAT.2 690V Pollution degree 2
Voltage Test (Double-pole Test) IEC 60529(IP65)
Power source LR03 1.5V × 2 (3V)
• Connect both probes to the system Dimensions 241.5(L) × 68.5(W) × 28.5(D) mm
under test.
Weight 230g (including batteries)
• The voltage is indicated by LEDs.
Buzzer sounds and Live circuit LED
lights up when a threshold voltage Distance Between Probes
of 50V is exceeded.
• Distance between probes is selectable, either 16.7mm or
• Voltage polarity is indicated in fol- 19.0mm, by changing probes (L1 and L2) position manually.
lowing manner.

AC +DC -DC

Single-pole Phase Test 4mm Tips Replacement

Unscrew Tighten
16.7mm 19mm

• Live circuit LED lights up and


buzzer sounds when a voltage of
approx. 100V AC or more exists • How to fixing 4mm Tips on
in the object under test. L1 probe – and L2 probe +.
10
KEW DIGITAL MULTIMETERS
MODEL 2000 φ6 MAX
AC/DC 60A /2001 φ10 MAX
AC/DC 100A KEW MATE

MODEL 2000 MODEL 2001


AC V DC V DC V 340mV/3.4/34/340/600V (Input impedance : 10MΩ)
±1.5%rdg±4dgt
Continuity AC V 3.4/34/340/600V (Input impedance : 10MΩ)
±1.5%rdg±5dgt[50~400Hz]
Hz DC A 60A ±2%rdg±5dgt 100A ±2%rdg±5dgt
AC A 60A ±2%rdg±5dgt(50/60Hz) 100A ±2%rdg±5dgt(50/60Hz)
Ω 340Ω/3.4/34/340kΩ/3.4/34MΩ
±1%rdg±3dgt(0~340kΩ)
±5%rdg±5dgt(3.4MΩ)
±15%rdg±5dgt (34MΩ)
Frequency (AC A)3.4/10kHz ±0.1%rdg±1dgt
(AC V)3.4/34/300kHz ±0.1%rdg±1dgt
(Input sensitivity (Input sensitivity
Current:more than 15A Current:more than 25A
Voltage:more than 30V) Voltage:more than 30V)
Continuity buzzer 6mm max. 10mm max.
Withstand voltage 3700V AC for 1 minute
Applicable standards IEC 61010-1 CAT.Ⅲ 300V Pollution degree 2
IEC 61010-031, IEC 61010-2-032, IEC 61326-1
photo : 2001
Power source R03(DC1.5V) x 2
※Continuous measuring time : approx. 45 hours
• Capable of measuring AC and DC currents up to 60A(MODEL 2000) (Auto power off : approx. 10 minutes)

/100A(MODEL 2001) with OPEN CLAMP SENSOR. Dimensions 128(L) × 87(W) × 21(D)mm 128(L) × 91(W) × 27(D)mm
• 3400 counts with bargraph display. Weight 210g approx. 220g approx.

2000/2001
• Pocket size and heavy duty design. Accessories R03(1.5V) × 2
• Sleep function to save battery consumption. Instruction manual
• Designed to international safety standard IEC61010-1 CAT.3 300V Optional 9107(Carrying case[Soft])

MODEL
2300R

FORK CURRENT TESTER


MODEL KEW FORK CURRENT TESTER

φ10 MAX MODEL 2300R


AC/DC 100A Current AC A 0~100.0A
measurement ±2.0%rdg±5dgt (50/60Hz)
DC A 0~±100.0A
±2.0%rdg±5dgt
Crest factor 2.5
Non contact Detect AC voltage without contacting with socket wire
RMS
voltage During voltage detection, “Hi” flashes and a buzzer sounds
Maximum digit 1,049
Conductor size Max φ10mm
Applicable standard IEC 61010-1 CAT.Ⅲ 300V Pollution degree 2
Power source R03 (AAA) × 2 (Auto power off : approx. 10 minutes)
Dimensions 161.3(L) × 40.2(W) × 30.3(D)mm
Weight 110g (including batteries)
Accessories 9113(Carrying case)
R03 (AAA) × 2
Instruction manual
2300R

•True RMS reading is an essential feature for accurate measurement.


•"Non Contact" voltage function indicates the presence of AC voltage by warning the
user with an audible signal.
MODEL

•Set the DC current range to zero in one touch with the Zero Adjust function.
•Auto Power Off.
•Data Hold (AC A / DC A only).
•Designed to international safety standard IEC61010-1 CAT.3 300V.

KEW FORK 2300R can be used in crowded connection boxes, where cables are very
short, and space is too limited to clamp cables using with a traditional clamp meter.
11
KEW ANALOGUE CLAMP METERS
2608A
MODEL 2608A

AC A 6/15/60/150/300A ±3% of FS
MODEL AC V 150/300/600V ±3% of FS
DC V 60V ±3% of FS

φ33 MAX
AC 300A °C
1/10kΩ(25/250Ω mid-scale)
±2% of scale length
Temperature -20°C~+150°C(with the use of Temperature probe 7060)
AC V DC V ±5°C(0°C~+100°C) ±10°C(other ranges)
Conductor size φ33mm max.
Frequency response 50/60Hz
Withstand voltage 3700V AC for 1 minute
Applicable IEC 61010-1 CAT.3 300V Pollution degree 2
standards IEC 61010-031 IEC 61010-2-032
Power source R6P(AA)(1.5V) × 1
• DC voltage range is also available Dimensions 193(L) × 78(W) × 39(D)mm
especially for checking emergency Weight 275g approx.
battery operated power supply. Accessories 7066(Test leads) 8901(Fuse [0.5A/250V]) × 2
• Can measure temperature using op- 9097(Carrying case) R6P(AA) × 1
tional probe. Instruction manual
• Tear drop shaped transformer jaws Optional 7060(Temperature probe)
for ease of use. 8004/8008(Multi-tran)

2805
MODEL 2805
AC A 6/20/60/200/600A ±3% of FS
MODEL AC V 150/300/600V ±3% of FS
Ω 2kΩ(25Ω mid-scale)

φ35 MAX
AC 600A AC V
±3% of scale length
Conductor size φ35mm max.
Frequency response 50/60Hz
Withstand voltage 2200V AC for 1 minute
Power source R6P(AA)(1.5V) × 1
Dimensions 220(L) × 83(W) × 40(D)mm
• Range switch selects only one rotary Weight 390g approx.
scale at a time, making it easy to take Accessories 7067(Test leads) 8901(Fuse [0.5A/250V]) × 2
readings correctly. 9144(Carrying case) R6P(AA) × 1
• A long time seller with proven reputation Instruction manual
world wide for its easy-to-use functions. Optional 8004/8008(Multi-tran)
MODEL

Selection Guide
MODEL 2608A MODEL 2805
2608A

AC A 300A 600A
AC V 600V 600V
DC V 60V
Ω 10kΩ 2kΩ
Temperature

What Are Clamp Meters?


MODEL

Clamp meters are a very convenient testing instrument that Using the clamp meter, however, we can measure current
permits current measurements on a live conductor without by simply clamping on a conductor as illustrated in Fig.2.
circuit interruption. When making current measurements with One of the advantages of this method is that we can even
2805

the ordinary multimeter, we need to cut wiring and connect measure a large current without shutting off the circuit being
the instrument to the circuit under test as shown in Fig.1. tested.

Multimeter Simply clamp on a


conductor for current
measurement.
Test
Lead Current

Current Current
Power
Power Supply Load
Supply Cut wiring and Load
connect multimeter
Clamp
to current circuit
Meter
under test.

Fig.1 Measurement using multimeter Fig.2 Measurement using clamp meter


12
KEW DIGITAL CLAMP METERS
MODEL 2002PA/2002R
MODEL 2002PA MODEL 2002R
2002R
• φ55
AC A 400A(0~400A) 400A(0~400A)
±1%rdg±3dgt[50/60Hz] ±1.5%rdg±3dgt[45~65Hz]
MAX
AC2000A AC V DC V ±2%rdg±3dgt[40Hz~1kHz] ±2.5%rdg±3dgt[40Hz~1kHz]
2000A(0~1500A) 2000A(0~1500A)
PEAK OUT ±1%rdg±3dgt[50/60Hz] ±2%rdg±5dgt[45~65Hz]
10ms PUT
±3%rdg±3dgt[40Hz~1kHz] ±3%rdg±5dgt[40Hz~1kHz]
2000A(1500~2000A) 2000A(1501~2000A)
Continuity ±3.0%rdg[50/60Hz] ±4%rdg[50/60Hz]
AC V 40/400/750V 40/400/750V
±1%rdg±2dgt[50/60Hz] ±1%rdg±2dgt[45~65Hz]
±1.5%rdg±3dgt[40Hz~1kHz] ±1.5%rdg±3dgt[40Hz~1kHz]
DC V 40/400/1000V ±1%rdg±2dgt
Continuity buzzer buzzer sounds below 50±35Ω
Ω 400Ω/4k/40k/400kΩ ±1.5%rdg±2dgt
photo : 2002R Conductor size φ55mm max.
Frequency response 40Hz~1kHz
Output voltage 400/2000A DC400mV/200mV
• Can measure large AC current up to 2000A. Withstand voltage 5550V AC for 1 minute
• Peak hold function. Applicable IEC 61010-1 CAT.3600V, CAT.21000V
• 55mm-dia large tear drop shaped jaws. standards IEC 61010-031 IEC 61010-2-032 IEC 61326-1
Power source R6P(AA)(1.5V) × 2
※Continuous measuring time : approx. 150 hours (2002PA)
※Continuous measuring time : approx. 80 hours (2002R)
(Auto sleep function : approx. 10 minutes)
Dimensions 247(L) × 105(W) × 49(D)mm
Weight 470g approx.
Accessories 7107(Test leads) 8201(Output plug)
9094(Carrying case) R6P(AA) × 2 Instruction manual
Optional 8008(Multi-tran) 7014(Output cord)

2006
MODEL 2006

AC A 2/20/200A
MODEL ±2%rdg±5dgt[50Hz~1kHz](2/20A)
±2%rdg±5dgt[50/60Hz](200A)

2002PA/2002R
φ19 MAX
AC 200A AC V
±3%rdg10±dgt[40Hz~1kHz](200A)
AC V 2/20/200/500V
±1.5%rdg±2dgt[50/60Hz] ±1.5%rdg±5dgt[40Hz~1kHz]
DC V Continuity DC V 2/20/200/500V ±1%rdg±2dgt
Ω 2kΩ ±1.5%rdg±2dgt
Continuity buzzer buzzer sounds below 300~400Ω
Conductor size φ19mm max.
• Pocket size, handy clamp meter. Frequency response 40Hz~1kHz
• UL listed fire retardant plastic housing Withstand voltage 2200V AC for 1 minute
case. Power source R6P(AA)(1.5V) × 2 ※Continuous measuring time : approx. 300 hours

MODEL
• Multifunction instrument having voltage Dimensions 184(L) × 54(W) × 32(D)mm
and resistance measurement functions Weight 160g approx.
in addition to all the ranges incorpo- Accessories 7066(Test leads)
rated. 9066(Carrying case)
R6P(AA) × 2
Instruction manual
Optional 8004/8008(Multi-tran) 2006

2007A
MODEL 2007A

AC A 400/600A
MODEL

MODEL ±1.5%rdg±4dgt[50/60Hz] ±2%rdg±5dgt[40~400Hz]


AC V 400/750V

φ33 MAX
AC 600A AC V
±1.2%rdg±3dgt[50/60Hz] ±1.5%rdg±4dgt[40~400Hz]
Ω 400/4000Ω
±1.5%rdg±2dgt
Continuity Continuity buzzer buzzer sounds below 50±35Ω
Conductor size φ33mm max.
Frequency response 40Hz~400Hz
2007A

Withstand voltage 3700V AC for 1 minute


• Sleep function to save battery. Applicable IEC 61010-1 CAT.3300V, CAT.2600V, CAT.11000V
• Data hold function. standards IEC 61010-031 IEC 61010-2-032 IEC 61326(EMC)
• Digital display with maximum 4000 counts. Power source R03(AAA)(1.5V) × 2
※Continuous measuring time : approx. 200 hours (Auto sleep function : approx. 10 minutes)

Dimensions 195(L) × 78(W) × 36(D)mm


MODEL

Weight 260g approx.


Accessories 7066(Test leads)
9097(Carrying case)
R03(1.5V) × 2
Instruction manual
Optional 8004/8008(Multi-tran)
13
KEW DIGITAL CLAMP METERS
2017
MODEL 2017

AC A 200/600A
MODEL ±1.5%rdg±4dgt[50/60Hz](200A)
±1%rdg±3dgt[50/60Hz](600A)

φ33 MAX
AC 600A AC V
±2%rdg±5dgt[45Hz~1kHz]
AC V 200/600V
±1%rdg±2dgt[50/60Hz]
Continuity ±1.5%rdg±4dgt[45Hz~1kHz]
Ω 200Ω
±1.2%rdg±2dgt
• Tear drop shaped jaws for ease of use in Continuity buzzer buzzer sounds below 30±20Ω
tight places and crowded cable areas. Conductor size φ33mm max.
• Designed to meet internationally proven Frequency response 45Hz~1kHz
safety standards such as IEC61010-1, Withstand voltage 5550V AC for 1 minute
UL3111 and VDE0411. Applicable IEC 61010-1 CAT.3 600V Pollution degree 2
• Three functions in one unit; AC current, standards IEC 61010-031
AC voltage and resistance. Power source 6F22(9V) × 1 ※Continuous measuring time : approx. 200 hours
• Resistance range provides audible con- Dimensions 208(L) × 91(W) × 40(D)mm
tinuity test. Weight 400g approx.
• Frequency response from 40Hz to 1kHz Accessories 7066(Test leads)
on AC current and voltage ranges. 9079(Carrying case)
6F22 × 1 
Instruction manual
Optional 8004/8008(Multi-tran)

2027
MODEL 2027

AC A 200/600A(True RMS)
MODEL ±1.5%rdg±4dgt[50/60Hz] (CF<3)
±2%rdg±5dgt[40Hz~1kHz](Sine wave)

φ33 AC 600AMAX AC V 200/600V(True RMS) (CF<3)


±1.5%rdg±4dgt[50/60Hz]
±2%rdg±5dgt[40Hz~1kHz]
AC V Continuity Ω 200Ω
RMS ±1.2%rdg±4dgt
Continuity buzzer buzzer sounds below 30±20Ω
• True RMS reading instrument that Conductor size φ33mm max.
permits precise measurements of non- Frequency response 40Hz~1kHz
sinusoidal waveform AC current and Withstand voltage 5550V AC for 1 minute
voltage. Accurate measurements are Applicable IEC 61010-1 CAT.3 600V Pollution degree 2
MODEL

also possible at low frequencies from standards IEC 61010-031


10Hz upwards. Power source 6F22(9V) × 1 ※Continuous measuring time : approx. 200 hours
• Designed to meet internationally proven Dimensions 208(L) × 91(W) × 40(D)mm
2017

safety standards such as IEC61010-1, Weight 400g approx.


UL3111 and VDE0411. Accessories 7066(Test leads)
• Three functions in one unit; AC current, 9079(Carrying case)
AC voltage and resistance. 6F22 × 1 
Instruction manual
Optional 8004/8008 (Multi-tran)
MODEL

2031
MODEL 2031

AC A 20A
MODEL ±2%rdg±5dgt[50Hz~1kHz]
2027

200A

φ24 MAX
AC 200A
±2%rdg±5dgt[50/60Hz]
±3%rdg±10dgt[40Hz~1kHz] 
Conductor size φ24mm max.
Frequency response 40Hz~1kHz
Withstand voltage 3700V AC for 1 minute
Applicable IEC 61010-1 CAT.3 300V
standard
Power source LR-44(1.5V) × 2
※Continuous measuring time : approx. 100 hours (Auto power off : approx. 10 minutes)
Dimensions 147(L) × 58.5(W) × 26(D)mm
MODEL

Weight 100g approx.


• Can measure large AC current up to 200A. Accessories 9090 (Carrying case)
• 24mm-dia tear drop shaped jaws. LR-44 × 2
2031

Instruction manual
Optional 8004/8008 (Multi-tran)

14
KEW DIGITAL CLAMP METERS
2040
KEW 2040

AC A 0~600.0A
KEW ±1.5%rdg±5dgt(50/60Hz)
±3.5%rdg±8dgt(40~400Hz)

φ33 MAX
AC 600A AC V
AC V 6/60/600V
Auto Ranging
±1.3%rdg±4dgt(50/60Hz)
DC V Hz ±3.0%rdg±5dgt40~400Hz)
DC V 600m/6/60/600V
#!4Ⅳ Auto Ranging
Continuity 6
±1.0%rdg±3dgt
Ω 600/6k/60k/600k/6M/60MΩ (Auto Ranging)
±1%rdg±5dgt(600~6M) / ±5%rdg±8dgt(60M)
Continuity buzzer Buzzer Sounds at 100Ω
Hz 10/100/1k/10kHz(Auto Ranging)
(Input sensitivity
Current:more than 50A[~1kHz] Voltage:more than 1V[~10kHz]
DUTY 0.1~99.9%
(Pulse width / Pulse cycle) ±2.5%rdg±5dgt
Conductor size φ33
Withstand voltage 6880V AC for 5 seconds
Applicable standards IEC 61010-1 CAT.4 600V IEC 61010-031
IEC 61010-2-032 IEC 61326
Power source R03 (1.5V)(AAA) × 2
※Continuous measuring time : approx. 30 hours (Auto sleep function : approx. 15 minutes)
Dimensions 243(L) × 77(W) × 36(D) mm
Weight 300g
Accessories 7066(Test leads) 9094(Carrying case)
R03 × 2
Instruction manual
Optional 8004/8008(Multi-tran)(AC only)

• Designed to meet international safety standard IEC61010-1 CAT.4 600V


• CAT.4 Clamp Meters can measure the Voltage and Current in both very low and high power circuits.
• Thus, very useful for power distribution companies, power utilities and maintenance fields.
• Red LED, as “Non Contact Voltage” function, gives warning to the user on the presence of AC voltage.
• Double molding gives comfortable feeling in palm.
• 6039 counts with Bar Graph display.
• MIN./MAX. function enables to keep easily min. & max. value during measurement.

2040
How Do Clamp Meters Operate?
In general AC clamp meters operate on the principle of

KEW
current transformer(CT) used to pick up magnetic flux gen- l(A)

erated as a result of current flowing through a conductor. i(A)


Assuming a current flowing through a conductor to be the Current to Rectify- Analogue
primary current, you can obtain a current proportional to (Number Voltage
of turns) Conversion
ing
Circuit
to Digital
Conversion Display
the primary current by electromagnetic induction from the Circuit Circuit. Circuit

secondary side(winding) of the transformer which is con-


l : Current under Test (Primary Current)
nected to a measuring circuit of the instrument. This permits Transformer Jaws N : Number of Turns on CT Winding
(CT)
you to take an AC current reading on the digital display(in i : Secondary Current on CT

the case of digital clamp meters) as illustrated by the block l


i= (A)
diagram. N

Measurement Principle of AC/DC Clamp Meter


In general hall elements are used as a sensor to detect DC
current because it is not possible to employ an electromag- Hall Element
netic induction method as used for dedicated AC clamp
meters. As shown in a figure at left, a hall element is placed I(A)
Bias DC
across a gap created by cutting off part of the transformer circuit

jaws. When there occurs a flow of magnetic flux proportion- AC


al to both AC and DC primary currents in the transformer Unbalanced
voltage Amplify- Rectify- A/D
ing ing Conversion Display
jaws this hall element detects the magnetic flux and takes it compensating
circuit circuit circuit circuit circuit
out as an output voltage. Transformer
Hall element:This is a semiconductor to generate a voltage Jaws Gap

proportional to the product of bias current and magnetic Magnetic flux at this gap is proportional
to primary current under test l(A)
field on the output terminal when bias current is applied to
the input terminal.
15
KEW DIGITAL CLAMP METERS
2003A
KEW 2003A

AC A 400A/2000A(0~1000A)
KEW ±1.5%rdg±2dgt[50/60Hz] ±3%rdg±4dgt[40~500Hz]
±5%rdg±4dgt[500Hz~1kHz]

φ55 MAX
AC/DC 2000A AC V
2000A(1001~2000A)
±3%rdg±2dgt[50/60Hz]
DC A 400/2000A ±1.5%rdg±2dgt
DC V Continuity AC V 400/750V
±1.5%rdg±2dgt[50/60Hz] ±1.5%rdg±4dgt[40Hz~1kHz]
OUT MAX #!4Ⅳ DC V 400/1000V ±1%rdg±2dgt
PUT HOLD 6
Ω 400/4000Ω ±1.5%rdg±2dgt
Continuity buzzer buzzer sounds below 50±35Ω
Conductor size φ55mm max.
Frequency response 40Hz~1kHz
Output voltage 400/2000A DC400mV/200mV
Withstand voltage 6880V AC for 5 seconds
Applicable IEC 61010-1 CAT.4 600V, CAT.3 1000V
standards IEC 61010-031 IEC 61010-2-032
• Equipped to measure both AC and DC cur- Power source R6P(AA)(1.5V) ×2
※Continuous measuring time : approx. 100 hours (Auto sleep function : approx. 10 minutes)
rent with transformer jaws of large diameter.
• Can measure AC and DC currents up to Dimensions 250(L) × 105(W) × 49(D)mm
2000A. Weight 530g approx.
• Output terminal for connection to recorders. Accessories 7107(Test leads) 8201(Output plug)
• AC/DC voltage, resistance measurement 9094(Carrying case) R6P(AA) × 2 Instruction manual
and continuity functions also available. Optional 8008(Multi-tran)(AC only) 7014(Output cord)

2004
MODEL 2004

AC A 20/200A
MODEL ±1%rdg±2dgt[50/60Hz](20A)
±1.5%rdg±4dgt[40Hz~1kHz](20A)

φ19 MAX
AC/DC 200A AC V
±1.5%rdg±4dgt[50/60Hz](0~150A)
±2%rdg±5dgt[40Hz~1kHz](0~150A)
±3.5%rdg[40Hz~1kHz](>150A)
DC V DC A 20/200A ±1%rdg±2dgt(20A)
±1.5%rdg±2dgt(0~150A) ±3%rdg(>150A)
AC V 500V
• Smallest clamp meter capable of AC and ±1.5%rdg±2dgt[50/60Hz] ±2%rdg±4dgt[40Hz~1kHz]
DC current measurements. DC V 200V ±1%rdg±2dgt
• 20A range has a minimum resolution of Ω 200Ω ±1.5%rdg±2dgt
0.01A AC/DC. Conductor size φ19mm max.
• AC/DC voltage and resistance measure- Frequency response DC, 40Hz ~ 1kHz
KEW

ment functions also available. Withstand voltage 1000V AC for 1 minute


Power source R6P(AA)(1.5V) × 2 ※Continuous measuring time : approx. 40 hours
2003A

Dimensions 180(L) × 54(W) × 31(D)mm


Weight 170g approx.
Accessories 7066(Test leads)
9055(Carrying case)
R6P(AA) × 2
Instruction manual
Optional 8004/8008(Multi-tran)(AC only)

2009A
MODEL 2009A

AC A 400A(0~400A)(True RMS)
MODEL ±1.5%rdg±3dgt[50/60Hz] ±3%rdg±4dgt[30Hz~1kHz]
MODEL

2000A(150~1700A)(True RMS)

φ55 MAX
AC/DC 2000A
±1.5%rdg±2dgt[50/60Hz] ±3%rdg±4dgt[30Hz~1kHz]
2000A(1701~2000A)(True RMS)
2004

±3.5%rdg±3dgt[50/60Hz]
AC V DC V DC A 400/2000A ±1.5%rdg±2dgt
RMS
AC V 40/400/750V(True RMS)
OUT
Hz Continuity PUT
±1.5%rdg±3dgt[50/60Hz] ±2%rdg±4dgt[30Hz~1kHz]
DC V 40/400/1000V ±1%rdg±2dgt
PEAK Ω 400/4000Ω ±1.5%rdg±2dgt
10ms Continuity buzzer buzzer sounds below 20Ω
Hz 10 ~ 4000Hz ±1.5%rdg±5dgt
(Input sensitivity Current:more than 40A Voltage:more than 10V)

Conductor size φ55mm max.


MODEL

Frequency response 30Hz~1kHz


Output voltage 400/2000A DC400mV/200mV
Withstand voltage 5550V AC for 1 minute
2009A

Applicable IEC 61010-1 CAT.3 600V, CAT.2 1000V


standards IEC 61010-031 IEC 61010-2-032
• True RMS reading instrument ideal for Power source 6F22(9V) × 1
accurate measurement of distorted ※Continuous measuring time : approx. 15 hours (Auto sleep function : approx. 30 minutes)

waveforms and non-sinusoidal wave- Dimensions 250(L) × 105(W) × 49(D)mm


forms arising from thyristors. Weight 540g approx.
• Can measure AC and DC currents up to Accessories 7107(Test leads) 8201(Output plug) 9094(Carrying case)
2000A. 6F22 × 1 Instruction manual
• Output terminal for connection to recorders. Optional 7014(Output cord) 8008(Multi-tran)(AC only)
16
KEW DIGITAL CLAMP METERS
2010
MODEL 2010

AC A 200mA/2/20A
MODEL ±1%rdg±2dgt[50/60Hz](200mA)
±1.5%rdg±4dgt[40Hz~2kHz](200mA)

φ7.5 MAX
AC/DC 20A
OUT
PUT
±1%rdg±2dgt[50/60Hz](2A)
±2.5%rdg±5dgt[40Hz~2kHz](2/20A)
DC A 2/20A
External
Power Supply ±1%rdg±2dgt(2A) ±1.5%rdg±4dgt(20A)
Conductor size φ7.5mm max.
Frequency response DC 40Hz~2kHz
Output voltage 200mV DC for 200mA AC/DC and 2A/20A AC/DC full scale
Withstand voltage 750V AC for 1 minute
Power source 6LF22(9V Alkalline battery) × 1 or AC adaptor
※Continuous measuring time : approx. 20 hours (DC)/approx. 40 hours (AC)

Dimensions 142(L) × 64(W) × 26(D)mm : Display unit


153(L) × 23(W) × 18(D)mm : Sensor
Weight 220g approx.
• High sensitivity, miniature AC/DC clamp Accessories 9071(Carrying Case)
meter. 6LF22 × 1
• 0.1mA minimum resolution for AC cur- Instruction manual
rent and 1mA minimum resolution for Optional 8022(AC adaptor)(110V)
DC current. 8023(AC adaptor)(220V)
• Output terminal for recorder connection. 7014(Output cord)

2033
MODEL 2033
AC A 40/300A
MODEL ±1%rdg±4dgt[50/60Hz](0~40A)
±2.5%rdg±4dgt[20Hz~1kHz](0~40A)

φ24 MAX
AC/DC 300A
±1.5%rdg±4dgt[50/60Hz](20~200A)
±2.5%rdg±4dgt[20Hz~1kHz](20~200A)
±3.5%rdg[50/60Hz](200~300A)
±4%rdg[20Hz~1kHz](200~300A)
• Smallest clamp meter capable of AC and DC A 40/300A ±1%rdg±4dgt(0~±40A)
DC current measurements. ±1.5%rdg±4dgt(±20~±200A) ±3%rdg(±200~±300A)
• 300A auto ranging has minimum resolu- Conductor size φ24mm max.
tion of 0.01A AC/DC. Frequency response DC 20Hz~1kHz
• Auto-zero function to allow one touch Withstand voltage 3700V AC for 1 minute
zero adjustment. Applicable IEC 61010-1 CAT.3 300V
standards IEC 61010-2-032
Power source LR-44(1.5V) × 2

2010
※Continuous measuring time : approx. 10 hours (Auto sleep function : approx. 5 minutes)

Dimensions 147(L) × 59(W) × 25(D)mm


Weight 100g approx.
Accessories 9090(Carrying case)

MODEL
LR-44 × 2
Instruction manual
Optional 8004/8008(Multi-tran)(AC only)

2037
MODEL 2037

AC A 400/600A(True RMS)
MODEL ±1.5%rdg±5dgt[50/60Hz](CF<3)
±3.5%rdg±5dgt[40Hz~1kHz]
PEAK
DC200ms
DC A 400/1000A 2033
AC500ms Continuity ±1%rdg±5dgt
AC V 40/400/600V(True RMS)
φ33 MAX
AC 600A
MAX
DC1000A ±1.5%rdg±5dgt[50/60Hz](CF<3)
RMS ±3.5%rdg±5dgt[40Hz~1kHz]
MODEL

AC V DC V DC V 40/400/600V
±1%rdg±5dgt
Ω 400/4000Ω
Hz AVG LoHz
±1%rdg±5dgt
Continuity buzzer buzzer sounds below 20Ω
Hz 3000Hz ±1.5%rdg±5dgt
(Input sensitivity Current:more than 40A Voltage:more than 8V)

Conductor size φ33mm max.


Frequency response DC 10Hz~1kHz
2037

Withstand voltage 5550V AC for 1 minute


Applicable IEC 61010-1 CAT.3 600V Pollution degree 2
• Measures both AC and DC current and standards IEC 61010-031
voltage with high accuracy. Power source 6F22(9V) × 1
MODEL

※Continuous measuring time : approx. 15 hours (Auto sleep function : approx. 30 minutes)
• True RMS reading instrument that permits
precise measurements of non-sinusoidal Dimensions 208(L) × 91(W) × 40(D)mm
waveform AC current and voltage. Ac- Weight 450g approx.
curate measurements are also possible at Accessories 7066(Test leads) 9079(Carrying case)
low frequencies from 10Hz upwards. 6F22 × 1
• Peak, average and frequency measure- Instruction manual
ment functions. Optional 8004/8008(Multi-tran)(AC only)
17
KEW DIGITAL CLAMP METERS
2046R
KEW 2046R

AC A 0~600.0A ±2.0%rdg±5dgt(50/60Hz) ±3.5%rdg±5dgt(40~500Hz)


KEW DC A 0~600.0A ±1.5%rdg±5dgt
AC V 6/60/600V(Auto Ranging)

φ33 -!8
!#$#!
±1.5%rdg±4dgt(50/60Hz) ±3.5%rdg±5dgt40~400Hz)
DC V 600m/6/60/600V(Auto Ranging) ±1.0%rdg±3dgt
Ω 600/6k/60k/600k/6M/60MΩ(Auto Ranging)
AC V DC V ±1%rdg±5dgt(600~6M) / ±5%rdg±8dgt(60M)
RMS
Continuity buzzer Buzzer Sounds at 100Ω
Continuity Hz Hz 10/100/1k/10kHz(Auto Ranging)
(Input sensitivity Current:more than 50A[~1kHz] Voltage:more than 1V[~10kHz])
DUTY 0.1~99.9%
#!4Ⅳ
°C 6
±2.5%rdg ±5dgt (Pulse width/Pulse cycle)
Capacitance test 400n/4µ/40µF(Auto Ranging)
Temperature -50°C~+300°C(with the use of Temperature probe 8216)
Conductor size φ33
Withstand voltage 6880V AC for 5 seconds
Applicable standards IEC 61010-1 CAT.4 600V
IEC 61010-031, IEC 61010-2-032, IEC 61326
Power source R03 (1.5V)(AAA) × 2
※Continuous measuring time : approx. 10 hours (Auto power off : approx. 15 minutes)

Dimensions 243(L) × 77(W) × 36(D) mm


Weight 300g
Accessories 7066(Test leads) 9094(Carrying case) R03 × 2
Instruction manual
Optional 8004/8008(Multi-tran)(AC only) 8216(Temperature probe)

2055/2056R
KEW 2055 KEW 2056R

AC A 0~600.0/1000A 0~600.0/1000A
KEW ±1.5%rdg±5dgt(50/60Hz) ±2.0%rdg±5dgt(50/60Hz)
±3.0%rdg±5dgt(40~400Hz) ±3.5%rdg±5dgt(40~500Hz)

φ40 MAX
AC/DC 1000A AC V
DC A 0~600.0/1000A ±1.5%rdg±5dgt
AC V 6/60/600V(Auto Ranging) 6/60/600V(Auto Ranging)
±1.3%rdg±4dgt(50/60Hz) ±1.5%rdg±4dgt(50/60Hz)
DC V Continuity ±3.0%rdg±5dgt40~400Hz) ±3.5%rdg±5dgt40~400Hz)
DC V 600m/6/60/600V(Auto Ranging) ±1.0%rdg±3dgt
#!4Ⅳ
Hz 6
Ω 600/6k/60k/600k/6M/60MΩ (Auto Ranging)
±1%rdg±5dgt(600~6M) / ±5%rdg±8dgt(60M)
Continuity buzzer Buzzer Sounds at 100Ω
ÓäxÈ,

Capacitance test 400n/4µ/40µF(Auto Ranging)
Temperature -50°C~+300°C
UÊ ÓäxÈ, (with the use of Temperature probe 8216)
KEW

Hz 10/100/1k/10kHz(Auto Ranging)
c
UÊ ÓäxÈ, (Input sensitivity Current:more than 50A[~1kHz] Voltage:more than 1V[~10kHz])
2046R

photo : 2056R DUTY 0.1~99.9%


±2.5%rdg ±5dgt (Pulse width/Pulse cycle)
Conductor size φ40
Features (2046R/2055/2056R) Withstand voltage 6880V AC for 5 seconds
• Designed to meet international safety standard IEC61010-1 CAT.4 600V Applicable standards IEC 61010-1 CAT.4 600V
• CAT.4 Clamp Meters can measure the Voltage and Current in both IEC 61010-031, IEC 61010-2-032, IEC 61326
very low and high power circuits. Power source R03 (1.5V)(AAA) × 2
※Continuous measuring time : approx. 35 hours (Auto sleep function : approx. 15 minutes) (2055)
• Thus, very useful for power distribution companies, power utilities and ※Continuous measuring time : approx. 10 hours (Auto power off : approx. 15 minutes) (2056R)
maintenance fields.
• True RMS enables an accurate measurement (2046R/2056R). Dimensions 254(L) × 82(W) × 36(D) mm
KEW

• Red LED, as “Non Contact Voltage” function, gives warning to the user Weight 310g
on the presence of AC voltage. Accessories 7066(Test leads) 9094(Carrying case) R03 × 2
2055/2056R

• Double molding gives comfortable feeling in palm. Instruction manual


• 6039 counts with Bar Graph display. Optional 8008(Multi-tran)(AC only) 8008(Multi-tran)(AC only)
• MIN./MAX. function enables to keep easily min. & max. value during measurement. 8216(Temperature probe)

True RMS (Root Mean Square) Value Measurement


ÛiÀ>}ˆ˜}Ê6>Õi /ÀÕiÊ,-Ê6>Õi
instead of 9.7A with irregular wave-form. Accordingly, true RMS
type clamp meter is recommendable for the measurement of the
equipment with inverter control devices.
Due to the use of thyristors, inverters and other energy-saving
controllers in recent electric wiring, current waveforms often
include harmonic components and are distorted compared to
sinusoidal waves (50/60Hz).
The Kyoritsu True RMS value tester is able to measure distorted
When load current is not affected by the distortion, both
waveforms using true RMS since waveforms are being internally
averaging value type and true RMS (root mean square) type
calculated continuously. In contrast, when measurements are
clamp meters show the almost same value of about 10A with
made with a averaging value tester, errors are generated in the
constant wave-form as the above display samples. However,
measurement value because the tester cannot continuously track
when load current is affected by some distortions such as
distorted waveforms.
inverter, etc...,averaging value type clamp meter indicates 5.5A
(Compared to the true RMS value tester, measurement values for the averaging value
instead of 9.7A and true RMS type clamp meter indicates 7.9A generate more than 30% errors in some cases.)
18
KEW LEAKAGE CLAMP METERS
2412
MODEL 2412

AC A 20/200mA/2/20/200/500A ±1.5%rdg±5dgt(20/200mA/2A)
MODEL (50/60Hz) ±2%rdg±5dgt(20/200A) ±2.5%rdg±5dgt(500A)
AC A 20/200mA/2/20/200/500A
±1%rdg±3dgt[50/60Hz] ±5%rdg±5dgt[40~400Hz](20/200mA/2A)
φ40 MAX
AC 500A
Resolution
0.01mA
(WIDE)
±1.5%rdg±3dgt[50/60Hz] ±5%rdg±5dgt[40~400Hz](20/200A)
±2%rdg±3dgt[50/60Hz] ±5%rdg±5dgt[40~400Hz](500A)
OUT
AC V PUT AC V 600V ±2%rdg±5dgt[50/60Hz] ±5%rdg±5dgt[40~400Hz]
Ω 200Ω ±1.5%rdg±5dgt
External
Filter Power Supply
Conductor size φ40mm max.
Frequency response 40~400Hz
• Digital clamp meter with tear drop Effect of external stray10mA AC max.
shaped, medium size transformer magnetic field φ15mm 100A
jaws specially designed for leak- Output DC200mV against 2000 count
age current measurement. Withstand voltage 3700V AC for 1 minute
• Frequency filter switch to eliminate Power source 6F22(9V) × 1 or AC adaptor
※Continuous measuring time : approx. 100 hours (Auto power off : approx. 60 minutes)
the effect of harmonics.
• Output terminal for connection to Dimensions 209(L) × 96(W) × 45(D)mm
recorders and facility to operate Weight 450g approx.
from external power supply permit Accessories 7066(Test leads) 9072(Carrying case)
continuous leakage current moni- 8025(Output plug) 6F22 × 1 Instruction manual
toring. Optional 8004/8008(Multi-tran) 8022(AC adaptor)(110V)
8023(AC adaptor)(220V) 7014(Output cord)
These Multi-trans can not be used for leakage current measurement.

MODEL 2413F/KEW 2413R


φ68 MAX Resolution MODEL 2413F KEW 2413R
AC1000A 0.1mA AC A 200mA/2/20/200A/1000A 200mA/2/20/200/1000A
(50/60Hz) ±1.5%rdg±2dgt(200mA/2/20A) ±2.5%rdg±5dgt(200mA/2/20A)
OUT PEAK
PUT 10/100ms Filter ±2%rdg±2dgt(200A/0~500A) ±3.0%rdg±5dgt(200A, 0∼500A)
±5.5%rdg(501~1000A) ±5.5%rdg(501∼1000A)
UÊÓ{£Î, AC A 200mA/2/20/200A/1000A 200mA/2/20/200/1000A
(WIDE) ±1%rdg±2dgt[50/60Hz] ±1.8%rdg±5dgt[50/60Hz]
±3%rdg±2dgt[40Hz~1kHz](200mA/2/20A) ±3.0%rdg±5dgt[40Hz~1kHz](200mA/2/20A)
±1.5%rdg±2dgt[50/60Hz] ±2.0%rdg±5dgt[50/60Hz]
±3.5%rdg±2dgt[40Hz~1kHz](200A/0~500A) ±3.5%rdg±5dgt[40Hz~1kHz](200A, 0∼500A)
±5%rdg[50/60Hz] ±5.0%rdg[50/60Hz](501∼1000A)
±10%rdg[40Hz~1kHz](501~1000A)
Conductor size φ68mm max.
Frequency response 40Hz~1kHz

2412
Effect of external stray 10mA AC max.
photo : 2413R
magnetic field
φ15mm 100A
• Large tranceformer jaws of 68mm diameter makes it possible to clamp on all Output AC/DC 200mV against 2000 count

KEW
three or four wires (3 phases) together for leakage current measurement. Crest factor 3.0 or Less
• Frequency filter switch to eliminate the effect of the harmonics. Withstand voltage 3700V AC for 1 minute
• 2 way analogue output terminal Applicable standards IEC 61010-1 CAT.3 300V IEC 61010-2-032
• Measurement from mA up to AC 1000A Power source 6F22(9V) × 1 ※Continuous measuring time : approx. 35 hours (2413F)
※Continuous measuring time : approx. 60 hours (2413R)
• True RMS enables an accurate measurement for distorted waveforms.(2413R)
• Peak hold function Dimensions 250(L) × 130(W) × 50(D)mm
• Data hold function: Allows for easy reading in dimly light or hard-to-reach locations Weight 570g approx. 600g approx.
• Back light in the LCD (2413R) Accessories 9094(Carrying case) 6F22 × 1 Instruction manual
• International safety standard IEC61010-1 CAT. 3 300V Optional 7073(2WAY Output cord)
2413F

Method of leakage current measurement


MODEL

Broadly speaking, there are two methods of leakage


current measurement. One is designed to measure leak-
age current by directly clamping on an earthing con- /À>˜ÃvœÀ“iÀ £
ductor and the other is intended to measure leakage *œÜiÀ
current by clamping on two-way wires together. Please -Õ««Þ
œ>` i>Ž>}i

ÕÀÀi˜Ì
refer to Fig for respective measurement methods. The
Ó }
principle of measurement involving the clamping of two-
way wires together is meant to find out the difference
2413R

i>ÃÕÀi“i˜ÌÊLÞÊV>“«ˆ˜}Ê
Ìܜ‡Ü>ÞÊ܈ÀiÃÊ̜}i̅iÀ
of current flowing between the incoming wire and out- ­i>Ž>}iÊVÕÀÀi˜Ìʏ}­£‡Ó®ÜˆÊLi
`ˆÃ«>Þi`®
going wire and display the result. If there is no leakage
on the load side, the instrument display reads zero. If i>Ž>}iÊ
ÕÀÀi˜Ìʏ}
the leakage occurs on the load side, the leakage cur-
KEW

i>ÃÕÀi“i˜Ìʜ˜Êi>À̅ˆ˜}Ê܈Ài
rent will flow back into the power supply through earth, ­i>Ž>}iÊVÕÀÀi˜Ìʏ}Ê܈ÊLiÊ`ˆÃ«>Þi`®
resulting in the difference of current flowing between
the two-way wires which will then be displayed on the
instrument as a value of leakage current. Fig. Method of leakage current measurement.

19
KEW LEAKAGE CLAMP METERS
MODEL 2417

MODEL 2417 AC A
(50/60Hz)
200/2000mA/20/200/500A(True RMS)
±1.5%rdg±6dgt(200/2000mA)
±2%rdg±6dgt(20/200A)
±2.5%rdg±6dgt(500A)
φ40 MAX
AC 500A AC A 200/2000mA/20/200/500A(True RMS)
(WIDE) ±1%rdg±4dgt[50/60Hz]
Resolution
0.1mA Filter WP ±3%rdg±4dgt[40Hz~1kHz](200/2000mA)
RMS ±1.5%rdg±4dgt[50/60Hz]
±3.5%rdg±4dgt[40Hz~1kHz](20/200A)
±2%rdg±4dgt[50/60Hz]
±4%rdg±4dgt[40Hz~1kHz](500A)
Conductor size φ40mm max.
Frequency response40~400Hz
• Water and dust proof construction. 10mA AC max.
Effect of external stray
The instrument is protected against magnetic field φ15mm 100A
water and dust. Withstand voltage 3700V AC for 1 minute
• True RMS for accurate measure- Applicable standards IEC 61010-1 CAT.3 300V IEC 61010-2-032
ment of non-sinusoidal waveform Power source 6F22(9V) × 1
※Continuous measuring time : approx. 50 hours (Auto power off : approx. 30 minutes)
current.
• Selectable frequency response of Dimensions 209(L) × 96(W) × 45(D)mm
50/60Hz only or up to 1kHz. Weight 450g approx.
• Automatically turns power off in Accessories 9079(Carrying case) 6F22 × 1
about 30 minutes to conserve bat- Instruction manual
tery life. Optional 8004/8008(Multi-tran)
These Multi-trans can not be used for leakage current measurement.

2431
MODEL 2431

AC A 20/200mA/200A
MODEL (50/60Hz) ±3%rdg±5dgt(20/200mA/100A)
±5%rdg±5dgt(200A)
20/200mA/200A
φ24 MAX
AC 200A
Resolution
0.01mA
AC A
±2%rdg±4dgt[50/60Hz](20/200mA/0~100A)
(WIDE)
±5%rdg±6dgt[40~400Hz](20/200mA/0~100A)
Filter ±5%rdg±4dgt[50/60Hz](100.1~200A)
Conductor size φ24mm max.
Frequency response40~400Hz
Effect of external10mA AC max.
stray magnetic field
• Frequency Selector Switch to φ15mm 100A
eliminate the effect of harmonics. Withstand voltage 3700V AC for 1 minute
MODEL

• Three AC current ranges 20mA/ Applicable standards IEC 61010-1 CAT.3 300V IEC 61010-2-032
200mA/200A. Power source LR-44(1.5V)× 2
※Continuous measuring time : approx. 15 hours (Auto power off : approx. 10 minutes)
• 20mA range with a minimum
2417

resolution of 0.01mA. Dimensions 149(L)× 60(W) × 26(D)mm


• Auto power-off function (auto- Weight 120g approx.
matically turns off in about 10 Accessories 9090(Carrying case)
minutes). LR-44 × 2
• Rotary switch for easy one finger Instruction manual
power-on and range selection. Optional 8004/8008(Multi-tran)
These Multi-trans can not be used for leakage current measurement.

2432 High Sensitive Model


MODEL 2432
MODEL

AC A 4/40mA/100A
MODEL (50/60Hz) ±1%rdg±5dgt(4/40mA)
±1%rdg±5dgt(0~80A)
2431

±5%rdg(80.1~100A)
φ40 MAX
AC 100A
Resolution
0.001mA 4/40mA/100A
AC A
(WIDE) ±1%rdg±5dgt[50/60Hz] ±2.5%rdg±10dgt[20Hz~1kHz](4/40mA)
PEAK
Filter 10ms ±1%rdg±5dgt[50/60Hz] ±2.5%rdg±10dgt[40Hz~1kHz](0~80A)
±5%rdg[50/60Hz] ±10%rdg[40Hz~1kHz](80.1~100A)
Maximum 600V AC/DC (between line/neutral)
circuit voltage 300V AC/DC (against earth)
Conductor size φ40mm max.
Frequency response 20Hz~1kHz(40Hz~1kHz:100A)
Effect of external 2mA AC approx. in proximity to a 15mm-dia
stray magnetic field conductor carrying 100A AC
MODEL

Response time Approx. 2 seconds


Withstand voltage 3700V AC for 1 minute
Applicable standards IEC 61010-1 CAT.3 300V Pollution degree 2
2432

IEC 61010-2-032
Power source R03(DC1.5V) × 2
• Frequency Selector Switch to eliminate the effect of harmonics. ※Continuous measuring time : approx. 40 hours (Auto power off : approx. 10 minutes)

• Three AC current ranges:4mA/40mA/100A. Dimensions 185(L) × 81(W) × 32(D)mm


• Data hold function. Weight 290g approx.
• Peak hold function. Accessories 9097(Carrying case) R03(1.5V) × 2 Instruction manual
• Sleep function to save battery. Optional 8004/8008(Multi-tran)
• Designed to international safety standard IEC61010-1 CAT.3 300V These Multi-trans can not be used for leakage current measurement.
20
KEW LEAKAGE CLAMP METERS
MODEL 2433/2433R
MODEL 2433/2433R
• 2433R AC A 40/400mA/400A
(50/60Hz) ±1%rdg±5dgt(40/400mA)
φ40 MAX
AC 400A
Resolution
0.01mA ±1%rdg±5dgt(0~350A:2433, 0~300A:2433R)
±2%rdg(350.1~399.9A:2433, 300.1~399.9A:2433R)
PEAK
Filter 10ms
AC A 40/400mA/400A
(WIDE) ±1%rdg±5dgt[50/60Hz] 2.5%rdg±10dgt[20Hz~1kHz](40/400mA)
±1%rdg±5dgt[50/60Hz] ±2.5%rdg±10dgt[40Hz~1kHz]
(0~350A:2433, 0~300A:2433R)
±2%rdg[50/60Hz] ±5%rdg[40Hz~1kHz]
(350.1~399.9A:2433, 300.1~399.9A:2433R)
Maximum circuit voltage 600V AC/DC (between line/neutral) 300V AC/DC (against earth)
Conductor size φ40mm max.
Frequency response 20Hz~1kHz(40Hz~1kHz:400A)
Effect of external 10mA AC approx. in proximity to a 15mm-dia
photo : 2433R stray magnetic field conductor carrying 100A AC
Response time Approx. 2 seconds
Withstand voltage 3700V AC for 1 minute
Applicable standards IEC 61010-1 CAT.3 300V Pollution degree 2 IEC 61010-2-032
Power source R03 (DC1.5V) × 2
※Continuous measuring time : approx. 40 hours (2433)
• Frequency Selector Switch to eliminate the effect of harmonics. ※Continuous measuring time : approx. 24 hours (2433R)
• Three AC current ranges:40mA/400mA/400A. (Auto power off : approx 10 minutes)
• Data hold function. Dimensions 185(L) × 81(W) × 32(D)mm
• Peak hold function. Weight 270g approx.
• Sleep function to save battery. Accessories 9097 (Carrying case) R03(1.5V) × 2 Instruction manual
• Designed to international safety standard IEC61010-1 CAT.3 300V Optional 8004/8008 (Multi-tran)
These Multi-trans can not be used for leakage current measurement

2434
MODEL 2434

AC A(50/60Hz) 400mA/4/100A ±2%rdg±4dgt


MODEL AC A(WIDE) 400mA/4/100A ±2%rdg±4dgt[50/60Hz]
±3%rdg±5dgt[40~400Hz]
φ28mm max.
φ28 MAX
AC 100A
Resolution
0.1mA
Conductor size
40~400Hz
Frequency response
Effect of external 20mA AC max.
Filter

2433/2433R
stray magnetic field φ15mm 100A
Withstand voltage 3700V AC for 1 minute
Applicable standards IEC 61010-1 CAT.3 300V IEC 61010-2-032
Power source R03(AAA) (1.5V) × 2
※Continuous measuring time : approx. 150 hours(Auto sleep function : approx. 10 minutes)

Dimensions 169(L) × 75(W) × 40(D)mm


Weight 220g approx.
Accessories 9097(Carrying case) R03 × 2 Instruction manual
Optional 8004/8008(Multi-tran)

MODEL
These Multi-trans can not be used for leakage current measurement.

• Least affected by external stray magnetic field.


• 20mA AC max. in proximity to a 15mm-dia conductor carrying 100A AC
• Frequency Selector Switch to eliminate the effect of harmonics.
• Data hold function
• Sleep function to save battery
2434
Leakage Through Capacitors
MODEL

In fact there is also some leakage through


the capacitive components of an installa-
tion, particularly with extensive circuits or
where there are a lot of data processing
equipments connected. At mains frequency
(50 or 60 Hz), this phenomenon is of negli-
gible significance.
However, at higher frequencies, such as
those found in power supplies for computer
systems and microwave apparatus, capaci-
tive links can produce quite large leakage
currents.

21
KEW LEAKAGE CLAMP METERS
The KEW leakage clamp meters way to use
Let’s go back to the customer’s problem. If the RCD trips, it current the fault will be found.
should be temporarily “bridged out”. The contractor now simply In the fig. below there is a practical example how to trace the
clamps the Leakage Clamp Meter around both phase and neu- fault measuring the leakage current.
tral conductors on the supply side of the RCD(for 3-phase sys-
tems, all three live conductors and the neutral conductor should
be enclosed). Normally, using this tracing system the fault will be found but sometimes
The instrument display will then directly read the leakage current the earth leakage current will not be caused exclusively by low insulation
resistance.
to earth in the installation with a high resolution. In fact could happen that performing an insulation test there is not a low
Suppose the display reads 43.5 mA, simply tracing the leakage value of insulation resistance even if the RCD still trips!

43.5 =The leakage clamp reads leakage current

Meter 0.02 =The leakage clamp does not read the leakage current

Conductor
with bad
To PE insulation
RCD Temporarily
bridge out

43 0.
.5 02 43
.5

43 43
.5 .5

0.
02 0.
02
0.
02

PE

High frequency selector switch


This switch is designed to select “WIDE” or “50/60Hz” range. "WIDE"range - 56mA reading
“WIDE” range covers a wide frequency band of 40Hz to 1kHz. 200
mA
AC current having a fundamental waveform and harmonics
can be measured over this range. “50/60Hz” is restricted to a 100

frequency response of 40Hz to 100Hz and therefore permits 0


measurement of AC current of fundamental frequency only by
filtering harmonic content. When in doubt as to the presence
of harmonics you can identify it by using this frequency selector 0 10 20 30 40 50ms
switch. To give an example, the following shows the results of
AC current measurement on an earthing wire within a switchbox 20 "50/60Hz"range - 3mA reading
where there is an inverter based airconditioner is connected at mA

summertime. Model 2433 reads 56mA AC with the frequency 10


selector switch set at the “WIDE” position as shown, while it 0
displays 3mA at the “50/60Hz” switch position. The difference
between the two readings (56mA - 3mA = 53mA) is considered
leakage current caused by harmonics. The test also found that 0 10 20 30 40 50ms
this leakage current is flowing into single phase, 3-wire circuits
other than those connected with the inverters in the building Fig. Results of AC current measurement on earthing wire within
inspected. switchbox by using Model 2433 on the 400mA range.

22
KEW CLAMP METERS
Selection Guide
Analogue
Digital Clamp Meter AC/DC Digital Clamp Meter
Clamp Meter

MODEL 2608A 2805 2002PA 2006 2007A 2017 2027 2031 2040 2003A 2004 2009A 2010
2002R
Conductor size φ33 φ35 φ55 φ19 φ33 φ33 φ33 φ24 φ33 φ55 φ19 φ55 φ7.5
(MAX mm)
ACA MAX 300A 600A 2000A 200A 600A 600A 600A 200A 600A 2000A 200A 2000A 20A
MIN 6A 6A 400A 2A 400A 200A 200A 20A 400A 20A 400A 200mA
DCA MAX 2000A 200A 2000A 20A
MIN 400A 20A 400A 2A
ACV MAX 600V 600V 750V 500V 750V 600V 600V 600V 750V 500V 750V
MIN 150V 150V 40V 2V 400V 200V 200V 6V 400V 40V
DCV MAX 60V 1000V 500V 600V 1000V 200V 1000V
MIN 40V 2V 600mV 400V 40V
NCV ●
Frequency 10Hz~10kHz 10~4000Hz
Ω 1k/10k 2k 400/4k/ 2k 400/4k 200 200 600/6k/ 400/4k 200 400/4k
40k/400k 60k/600k/
6M/60M
Continuity buzzer ● ● ● ● ● ● ● ●
Sample rate Approx. Approx. Approx. Approx. Approx. Approx. Approx. Approx. Approx. Approx. Approx.
2.5 2 2.5 2.5 2.5 2 3 2.5 3 3 3
counts / sec counts / sec counts / sec counts / sec counts / sec counts / sec counts / sec counts / sec counts / sec counts / sec counts / sec
Data hold ● ● ● ● ● ● ● ● ● ● ● ● ●
Peak hold ● ● MAX ●
Analogue output ● ● ● ●
(FS) 400mV 400mV 400mV 200mV
Frequency 50/60 50/60 40~1k 40~1k 40~400 45~1k 40~1k 40~1k 40~400 DC DC DC DC
response (Hz) 40~1k 40~1k 30~1k 40~2k
True RMS ●(2002R) ● ●
Frequency filter
Temperature ●
Water proof
Power source R6P × 1 R6P × 1 R6P × 2 R6P × 2 R03 × 2 6F22 × 1 6F22 × 1 LR44 × 2 R03 × 2 R6P × 2 R6P × 2 6F22 × 1 6F22 × 1
Weight 275g 390g 470g 160g 260g 400g 400g 100g 300g 530g 170g 540g 220g
Page 11 11 12 12 12 13 13 13 14 15 15 15 16

Fork
AC/DC Digital Clamp Meter Digital Leakage Clamp Meter Current
Tester
MODEL 2033 2037 2046R 2055 2412 2413F 2417 2431 2432 2433 2434 2300R
2056R 2413R 2433R
Conductor size φ24 φ33 φ33 φ40 φ40 φ68 φ40 φ24 φ40 φ40 φ28 φ10
(MAX mm)
ACA MAX 300A 600A 600A 1000A 500A 1000A 500A 200A 100A 400A 100A 100A
MIN 40A 400A 600A 20mA 200mA 200mA 20mA 4mA 40mA 400mA
DCA MAX 300A 1000A 600A 1000A 100A
MIN 40A 400A 600A
ACV MAX 600V 600V 600V 600V
MIN 40V 6V 6V
DCV MAX 600V 600V 600V
MIN 40V 600mV 600mV
NCV ● ● ●
Frequency 10~3000Hz 10Hz~10kHz 10Hz~10kHz
Ω 4k 600/6k/ 600/6k/ 200
60k/600k/ 60k/600k/
6M/60M 6M/60M
Continuity buzzer ● ● ●
Sample rate Approx. Approx. Approx. Approx. Approx. Approx. Approx. Approx. Approx. Approx. Approx. Approx.
2.5 3 3 3 3 3 3 2 2.5 2.5 2.5 2
counts / sec counts / sec counts / sec counts / sec counts / sec counts / sec counts / sec counts / sec counts / sec counts / sec counts / sec counts / sec
Data hold ● ● ● ● ● ● ● ● ● ● ● ●
Peak hold ● ● ●(2056R) ● ● ●
Analogue output ● ●
(FS) 200mV 200mV
Frequency DC DC DC DC 40~400 40~1k 40~1k 40~400 40~1k 40~1k 40~400 50/60
response (Hz) 20~1k 10~1k 40~400 40~400
True RMS ● ● ●(2056R) ●(2413R) ● ●(2433R) ●
Frequency filter ● ● ● ● ● ● ●
Temperature ● ●(2056R)
Water proof ●
Power source LR-44 × 2 6F22 × 1 R03 × 2 R03 × 2 6F22 × 1 6F22 × 1 6F22 × 1 LR-44 × 2 R03 × 2 R03 × 2 R03 × 2 R03 × 2
Weight 100g 450g 300g 310g 450g 570g 450g 120g 290g 270g 210g 110g
Page 16 16 17 17 18 18 19 19 19 20 20 9

23
KEW MULTI-TRANS, CLAMP ADAPTOR
Adaptor designed to increase the measuring capability of your clamp MODEL 8004 MODEL 8008

meters. Measuring range 0~1000A AC 0~3000A AC


With the use of the multi-tran you can not only extend current ranges Ratio/Range 10 : 1 (input to output)
Accuracy ±3% of full scale ±2% of input±0.5A
but also clamp on a conductor of larger diameter.
Allowable 0~1000A(continuous)
measurement time 1000~1500A(10 minutes max.)

8004 MULTI-TRAN
3000A(30 seconds max.)
Conductor size φ60mm max. (50 × 75mm) φ100mm max.(100 × 150mm)
MODEL Frequency response 50Hz/60Hz
Safety standard IEC 61010-1 CAT.3300V
Pollution degree 2
φ60 MAX
AC1000A
Input to Output Ratio
10:1 Withstand voltage 3000V AC for 1 minute
Dimensions 240(L) × 85(W) × 30(D)mm 317(L) × 150(W) × 30(D)mm
45(L) × 40(W) × 10(D)mm Output coil 45(L) × 40(W) × 10(D)mm Output coil
Weight 490g approx. 750g approx.
Accessories 9022(Carrying case) 9056(Carrying case)
Applicable models 2002PA,2002R,2003A(AC only),2004(AC only),2006,
2007A(AC only),2009A(AC only),2608A,2805,2017,2027,
2037(AC only),2040(AC only),2046R(AC only),
2055(AC only),2056R(AC only),2412,2417,8113(AC only),
2031,2033(AC only),2431,2432,2433,2433R,2434
These Multi-trans can not be used for leakage current measurement.

How to Use
Clamp your instrument around the pick-up coil of the multi-
tran. Then, clamp the transformer jaws of the multi-tran on

MODEL 8008 MULTI-TRAN the conductor, as shown below. Multiply the reading of your
clamp meter by 10 to obtain the current value measured.

φ100 MAX Input to Output Ratio Transformer Jaws


AC3000A 10:1 Conductor under Test
MODEL
8004

Pickup Coll

Clamp Meter

Model 8006 is designed to measure AC current up to1500A.

8006
MODEL

MODEL AC CLAMP ADAPTOR It can accommodate up to 60mm-dia conductor or 50mm by 75mm


bus-bar.
8008

φ60 MAX
1500A
1A➞1mV
MODEL 8006

Measuring range 1500A AC


Output voltage 1mV AC/1A(1500A/1.5V)
Accuracy ±3%rdg+1A[45~65Hz](0~1000A)
±5%rdg[45~65Hz](1000~1500A)
Load resistance >1kΩ
Allowable 0~600A continuous 600~1000A 30 minutes max.
measurement time 1000~1500A 5 minutes max.
Conductor size φ60mm max. (50 × 75mm)
Frequency response 45~65Hz
MODEL

Withstand voltage 2200V AC for 1 minute


Dimensions 240(L) × 85(W) × 30(D)mm
Weight 500g approx.
8006

Accessories 9022(Carrying case)


Instruction manual

24
KEW CLAMP ADAPTORS
8112
MODEL 8112/8112BNC

MODEL AC CLAMP ADAPTOR Range Measuring ranges Output voltage Accuracy Frequency response
200mA AC 0~500mA AC1V/A ±1.5%rdg±0.2mA 50Hz~1kHz
AC 0~1000mA (1000mA/1V) ±3%rdg±0.4mA 40Hz~10kHz
±1%rdg±1mA 40Hz~1kHz
φ8 MAX
AC 120A
2A AC 0~20A AC100mV/A
(20A/2V) ±1.5%rdg±2mA 1k~10kHz
20A AC 0~20A AC10mV/A ±1%rdg±0.01A 40Hz~1kHz
200mA 2A 20A
1A➞1V 1A➞100mV 1A➞10mV AC 20~60A (120A/1.2V) ±2.5%rdg 50Hz~10kHz
AC 60~120A ±2.5%rdg 100Hz~10kHz
Conductor size φ8mm max.
Frequency response 30Hz~100kHz(-3dB)
Applicable standard IEC 61010-1 CAT. 2
100V Pollution degree 2(8112 Only)
Withstand voltage 500V AC for 1 minute
Dimensions 153(L) × 18(W) × 23(D)mm
Weight 100g approx.
Accessories 9057(Carrying case)
Instruction manual

Model 8112 clamp adaptor is designed to be an AC current/voltage con-


version probe capable of measuring AC current from 0.1mA to 120A in
conjunction with digital multimeters.Simple to operate, the unit has range
switch position at 200mA,2A and 20A. It also features safety design Example of Model 8112 BNC application
throughout with no exposed metal parts.

MODEL 8112BNC

8112
Model 8112BNC is an AC clamp adaptor designed for use with oscillo-
scopes. Output cord has a BNC connector which enables direct observa-
MODEL 8113
tion of current waveform on oscilloscope. Refer to a diagram shown at left
Range Measuring ranges Output voltage Accuracy Frequency response
for application. Specifications are same as those for Model 8112.

MODEL
AC 2A AC5A AC100mV/A ±2%rdg±5mA DC~1kHz
(5A/500mV)
20A AC50A AC10mV/A ±1.5%rdg±0.04A DC~1kHz
(50A/500mV)

8113
200A AC150A ±2%rdg±0.5A DC~1kHz
AC/DC AC1mV/A (0~150A)
MODEL CLAMP ADAPTOR AC200A (200A/200mV) ±3.5%rdg DC~1kHz
(150~200A)
φ19 MAX DC 2A DC5A DC100mV/A ±1.5%rdg±5mA
AC/DC 200A (5A/500mV) 8112BNC
2A 20A 200A 20A DC50A DC10mV/A ±1%rdg±0.02A
1A➞100mV 1A➞10mV 1A➞1mV (50A/500mV) (0~50A)
200A DC150A ±1.5%rdg±0.5A
DC1mV/A (0~150A)
DC200A (200A/200mV) ±3%rdg
MODEL

(150~200A)
Conductor size φ19mm max.
Frequency response DC~1kHz
Withstand voltage 1000V AC for 1 minute
Power source R6P(AA)(1.5V) × 2
Dimensions 180(L) × 54(W) × 31(D)mm
Weight 170g approx.
Accessories 7061(Output cords)
8113

Model 8113 is a clamp-on AC/DC current/voltage converter that permits AC/ R6P(AA) × 2
DC current measurements from 1mA to 200A in conjunction with a voltmeter 9055(Carrying case)
having 0.1mV resolution. Instruction manual
MODEL

25
KEW DIGITAL INSULATION/CONTINUITY TESTERS
3001B
MODEL 3001B

Insulation resistance
MODEL Test voltage 500V/1000V
Measuring ranges 200MΩ(2/20/200MΩ) autoranging
Compact and lightweight digital (Mid-scale value)
Insulation/Continuity tester. Output voltage Rated test voltage +12%
on open circuit
Rated current 1~1.1mA DC approx.
Output short 1.5mA DC approx.
circuit current
Accuracy ±2%rdg±1dgt
Continuity test
Measuring ranges 200Ω(20/200Ω) autoranging
(Mid-scale value)
Output voltage 600mV DC approx.
on open circuit

3005A
Output short 6mA approx.
circuit current
MODEL Accuracy ±2%rdg±0.1Ω±1dgt
General
Withstand voltage 2200V AC for 1 minute
Power source R6P(AA)(1.5V) × 8
Dimensions 144(L) × 93(W) × 61(D)mm
Weight 460g approx.
Accessories 7025(Test leads)
9050(Carrying case)
R6P(AA) × 8
Instruction manual

MODEL 3005A/3007A

Insulation resistance
Test voltage 250V/500V/1000V
Measuring ranges 20MΩ/200MΩ/2000MΩ
(Mid-scale value)

3007A
Output voltage Rated test voltage+20%
on open circuit -0%
MODEL Nominal current 1mA DC min.
Output short 1.5 mA DC approx.
circuit current
Accuracy ±1.5%rdg±5dgt(20MΩ/200MΩ) ±10%rdg±3dgt(2000MΩ)
MODEL

Continuity test
Measuring ranges 20Ω/200Ω/2000Ω
(Mid-scale value)
3007A

Output voltage 7~12V DC


on open circuit
Measuring current 200mA DC min.
Accuracy ±1.5%rdg±5dgt(20Ω) ±1.5%rdg±3dgt(200Ω/2000Ω)
AC voltage
AC voltage range 0~600V AC
Accuracy ±5%rdg±3dgt
General
Applicable IEC 61010-1 CAT.3 300V Pollution degree 2
standards IEC 61010-031 IEC 61557-1/2/4
IEC 60529(IP54) IEC 61326-1(EMC)
MODEL

Features (3005A/3007A) Withstand voltage 3700V AC for 1 minute


Power source R6P(AA)(1.5V) × 8
• Bar graph to display insulation resistance. Dimensions 185(L) × 167(W) × 89(D)mm
3005A

• Displays the value of external AC voltage along with flashing symbol. Weight 990g approx.(3007A)
• Auto null function to automatically subtract the test lead resistance before 970g approx.(3005A)
displaying the real continuity resistance value. Accessories 7122A(Test leads) 9074(Cord case)
• Trac-Lok mode to conserve battery life on insulation and continuity tests 8923(Fuse[F500mA/600V] ) × 2
(Model 3007A only ). R6P(AA) × 8 9121(Shoulder strap)
• Live circuit warning beeper. Instruction manual
• Releasing the test button automatically discharges the charges stored in
the circuit under test.
• Backlight function to view the test results in dimly lit areas (Model 3007A only).
• 200mA continuity measuring current to IEC 61557.
MODEL

• Minimum 1mA current on insulation tests to IEC 61557.


Selection Guide
Accessory
3001B

MODEL 3005A MODEL 3007A

250V test voltage


500V test voltage
1000V test voltage
200mA continuity range
Live circuit warning
Illuminated scale
MODEL 7122A Automatic discharge
Test leads
Trac-lok for extended battery life
26
KEW DIGITAL INSULATION/CONTINUITY TESTERS
KEW 3021/3022/3023
• 3 functions in one unit, insulation test with 4 voltage ranges, continuity
test, AC voltage measurement.
• 200mA measuring current on continuity testing.
• Comparator function with PASS / FAIL and buzzer.
• 0W adjustment at continuity measuring range.
• Memory function up to 99 data.
• Backlight LCD provides easy reading in dark locations.
• Safety lock system prevents an erroneous operation on 500 and 1000
Volt ranges.
• Safety standard IEC 61010-01 CAT.3 600V.

photo : 3021

a[mIFHG a[mIFHH a[mIFHI

)NSULATIONRESISTANCE
4ESTVOLTAGE 6 6 6 6 6 6 6 6 6 6 6 6
-EASURINGRANGE      
!UTORANGE -7 -7 -7 -7 -7 -7
&IRSTEFFECTIVE ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^
MEASURINGRANGE -7 -7 -7 -7 -7 -7 -7 -7 -7 -7 -7
-ID SCALEVALUE -7 -7 -7 -7 -7 -7
!CCURACY ÒRDG DGT
3ECONDEFFECTIVE
^-7
MEASURINGRANGELOWER
3ECONDEFFECTIVE ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^
MEASURINGRANGEUPPER -7 -7 -7 -7 -7 -7 -7 -7 -7 -7 -7
!CCURACY ÒRDG DGT
2ATEDCURRENT $#^M!
/UTPUTSHORTCIRCUITCURRENT M!MAX
7#ONTINUITY
!UTORANGE 7
!CCURACY ÒRDG DGT
/UTPUTVOLTAGEONOPENCIRCUIT 6Ò
/UTPUTSHORTCIRCUITCURRENT $#ÒM!

3021/3022/3023
&USE 1UICKACTINGCERAMICFUSE!6F¾MM
!#VOLTAGE
2ANGE !#^6(Z $#–^–6 ^ 6
!CCURACY ÒRDG DGT
'ENERAL
/THERFUNCTION $ATAHOLD :ERO7!$* !UTODISCHARGE "ARGRAPHDISPLAY -EMORY #OMPARATOR ,IVECIRCUITWARNING !UTOPOWEROFF "ATTERYALARM "ACKLIGHT
3AFETYLOCK 2EMOTEMEASUREMENT -EASUREMENTBUTTONLOCK#ONTINUOUSMEASUREMENT
!PPLICABLESTANDARDS )%# #!46)%#   )%# %-# )%#)0
$IMENSIONS7EIGHT , s7 s$ MMGAPPROX
0OWERSOURCE 20¾OR,2¾
!CCESSORIES 4EST,EADWITHREMOTECONTROLSWITCHSET
3HOULDERSTRAP 20!! s)NSTRUCTIONMANUAL
/PTIONAL %XTENSIONPROBE 0ICKELTYPEPROD #ARRYINGCASE
KEW

Comparator Function
Select and set the standard resis-
When measured 1MW
tance value in each measuring sign with
range, and compare it with read- Set the standard value at buzzer sound
10MW
ings.
Notice the result of comparison
by the or sign on the
display, and by buzzer sound at
same time.
Buzzer can be set either for sign indicated
or at your choice. Set the buzzer to be
beeped for sign

When measured 100MW

27
KEW ANALOGUE INSULATION/CONTINUITY TESTERS
3111V
MODEL 3111V

Insulation resistance
MODEL Test voltage 250V/500V/1000V
Measuring ranges 0~100MΩ/0~200MΩ/0~400MΩ
Compact, light weight and portable Insulation/Continuity tester. (Mid-scale value) (1MΩ) (2MΩ) (4MΩ)
Output voltage Rated test voltage ±10%
on open circuit
Rated current 0.8mA DC approx.
Output short 2mA DC approx.
circuit current
Accuracy guaranteed 0.05~10MΩ/0.1~20MΩ/0.2~40MΩ
ranges
Accuracy ±5% of indicated value
Continuity test
Measuring ranges 50Ω
(Mid-scale value) (20Ω)
Output voltage 0.6V DC approx.
on open circuit
Output short 300mA approx.
circuit current
Accuracy ±3% of scale length
General
Withstand voltage 2200V AC for 1 minute
Power source R6P(AA)(1.5V) × 8
Dimensions 143(L) × 93(W) × 63(D)mm
Weight 500g approx.
Accessories 7025(Test leads) 8902(Fuse[1A/250V])
9038(Carrying case)
R6P(AA) × 8 Instruction manual

3131A
MODEL 3131A

Insulation resistance
MODEL Test voltage 250V/500V/1000V
Measuring ranges 100MΩ/200MΩ/400MΩ
(Mid-scale value) (1MΩ) (2MΩ) (4MΩ)
Output voltage Rated test voltage +20%
on open circuit -0%
Nominal current 1mA DC min.
Output short 1.3 mA DC approx.
circuit current
MODEL

Accuracy 0.1~10MΩ/0.2~20MΩ/0.4~40MΩ
(Accuracy ruaranteed ranges) ±5% of indicated value
Continuity
3111V

Measuring ranges 2Ω/20Ω(1Ω)(10Ω)


(Mid-scale value)
Output voltage 4~9V DC
on open circuit
Measuring current 200mA DC min.
Accuracy ±3% of scale length
General
The Model 3131A offers unmatched performance, and feature in- Applicable IEC 61010-1 CAT.3 300V Pollution degree 2
cluding test lead resistance zero adjustment for time-saving continuous standards IEC 61010-031 IEC 61557-1/2/4
operation, a clear ease to read illuminated scale, and a live circuit IEC 60529(IP54) IEC 61326-1(EMC)
Withstand voltage 3700V AC for 1 minute
MODEL

warning.
Power source R6P(AA)(1.5V) × 6
Dimensions 185(L) × 167(W) × 89(D)mm
• Test insulation up to 100MΩ at 250V, 200MΩ at 500V, 400MΩ at Weight 860g approx.
3131A

1000V and continuity up to 20Ω. Accessories 7122A(Test leads) 9074(Cord case)


• LIVE circuit warning lamp plus audible warning. 8923(Fuse[F500mA/600V]) × 2
• Automatic discharge of circuit capacitance when TEST button is released. R6P(AA) × 6 9121(Shoulder strap) Instruction manual
• Fuse protected (continuity range only).
• Battery check LED.
• Front panel zero adjust.
• Back light function to facilitate working at dimly lit situations.
• PRESS TO TEST button with lock down feature.

Accessory Selection Guide


MODEL 3131A MODEL 3132A

3 range insulation test voltage


200mA continuity
Live circuit warning
AC voltage range
Illuminated scale
MODEL 7122A Automatic discharge
Test leads
IP54 rate

28
KEW ANALOGUE INSULATION/CONTINUITY TESTERS
3132A
MODEL 3132A

Insulation resistance
MODEL Test voltage 250V/500V/1000V
Measuring ranges 100MΩ/200MΩ/400MΩ
(Mid-scale value) (1MΩ) (2MΩ) (4MΩ)
Output voltage Rated test voltage+20%
on open circuit -0%
Nominal current 1mA DC min.
Output short 1~2mA DC
circuit current
Accuracy 0.1~10MΩ/0.2~20MΩ/0.4~40MΩ
(Accuracy guaranteed ranges) ±5% of indicated value
Continuity
Measuring ranges 3Ω/500Ω
(Mid-scale value) (1.5Ω/20Ω)
Output voltage 4.1V DC approx.
on open circuit
Measuring current 210mA DC min.
Accuracy ±1.5% of scale length
AC voltage
The Model 3132A is a highly compact and easy to use insulation
AC voltage range 0~600V AC
and continuity tester. Accuracy ±5% of scale length
Designed to strict IEC61010-1 safety standards, it has a protection General
degree IP54 and is ideally suited to more arduous environments. The Applicable IEC 61010-1 CAT.3 600V Pollution degree 2
instrument offers 3 insulation test ranges, a 3Ω continuity range and standards IEC 61010-031 IEC 61557-1/2/4
a 500Ω resistance range. IEC 60529(IP54) IEC 61326-1(EMC)
Withstand voltage 3700V AC for 1 minute
• Dust and drip proof construction. (designed to IEC60529 IP54) Power source R6P(AA)(1.5V) × 6
• Designed to meet IEC61010-1 and IEC61557 safety standard. Dimensions 106(L) × 160(W) × 72(D)mm
• 1mA rated test current at the minimum resistance. Weight 560g approx.
• 200mA measuring current on continuity testing. Accessories 7122A(Test leads) 9074(Cord case)
• Automatic discharge of circuit capacitance. 8923(Fuse[F500mA/600V]) × 2
(Any charge stored in the circuit under test will be automatically dis- R6P(AA) × 6 9121(Shoulder strap) Instruction manual
charged after testing.)
• Live circuit warning buzzer and neon lamp.
• Small and lightweight. Shock resistant new case material.
• AC voltmeter with linear, easy-to-read scale.
• Operates on AA, R6P×6 dry batteries.

3144A/3145A/3146A/3161A

3132A
MODEL
MODEL 3144A MODEL 3145A MODEL 3146A MODEL 3161A
Insulation resistance

MODEL
DC test voltage 250V/500V 125V/250V 50V/125V 15V/500V
Measuring ranges 100MΩ/200MΩ 50MΩ/100MΩ 20MΩ/50MΩ 10MΩ/100MΩ
Mid-scale value 1MΩ/2MΩ 0.5MΩ/1MΩ 0.2MΩ/0.5MΩ 0.05MΩ/2MΩ
First effective 0.05~20MΩ/ 0.02~10MΩ/ 0.01~5MΩ/ 0.005~2MΩ/
measuring ranges 0.1~50MΩ 0.05~20MΩ 0.02~10MΩ 0.1~50MΩ
Accuracy ±5% of indicated value
Second effective 20~50MΩ/ 10~20MΩ/ 5~10MΩ/ 2~10MΩ/

3144A/3145A/3146A/3161A
measuring ranges 50~100MΩ 20~50MΩ 10~20MΩ 50~100MΩ
Accuracy ±10% of indicated value
AC voltage
AC voltage range 600V 300V 300V 600V
Accuracy ±3% of full scale value
photo : 3144A
Applicable standards IEC 61010-1 CAT.3300V, CAT.2600V
Withstand voltage 3700V AC for 1 minute
• Miniature lightweight insulation tester. It weighs only 340g(battery Power source R6P(AA)(1.5V) × 4
included), but carries full measurement functions. Dimensions 90(L) × 137(W) × 40(D)mm
• Automatic discharge of circuit capacitance. Weight 340g approx.
• Test leads with remote control switch . Accessories 7149(Test lead with remote control switch set)
• New robust housing case. 9123(Shoulder strap)
• Back light function. R6P(AA) × 4 Instruction manual
• Neck strap for both hand’s operation. Optional 7116(Extension probe) 8016(Pickel type prod)

Accessory Optional
Accessories Selection Guide
MODEL 3144A MODEL 3145A MODEL 3146A MODEL 3161A

Test voltage 250V 125V 50V 15V


500V 250V 125V 500V
Illuminated scale
MODEL

Automatic discharge
Remote control switch
MODEL 7149 MODEL 8016
Test lead with remote control switch set Pickel type prod
(7161,7139,7131,8017,9041)
29
KEW ANALOGUE INSULATION TESTERS
MODEL 3165/3166
Model 3165 and 3166 are a simple, low cost, single range insulation tester. Miniaturized and weighing 330g only, they are available in
two versions having 500V/1000MΩ and 1000V/2000MΩ ranges respectively.

• 500V/1000MΩ (Model 3165)


• 1000V/2000MΩ (Model 3166)
• Expanded megohm scale for easy reading.
• New robust housing case to prevent damage.
• AC voltmeter scale for easy reading.
• Neck strap for both hand’s operation.

MODEL 3165 MODEL 3166

Insulation resistance
DC test voltage 500V 1000V
Measuring range 1000MΩ 2000MΩ
Mid-scale value 20MΩ 50MΩ
First effective 1~500MΩ 2~1000MΩ
measuring range
Accuracy ±5% rdg
Second effective 0.5/1000MΩ 1/2000MΩ
measuring range
Accuracy ±10% rdg
AC voltage
AC voltage range 600V
Accuracy ±3% of full scale value
Withstand voltage 3700V AC for 1 minute
Power source R6P(AA)(1.5V) × 4
photo : 3165 Dimensions 90(L) × 137(W) × 40(D)mm
Weight 330g approx.
Accessories 7025(Test leads) 9074(Cord case)
9123(Shoulder strap) R6P(AA) × 4
Instruction manual
MODEL

3315/3316
3165/3166

MODEL
MODEL 3315 MODEL 3316

Insulation resistance
DC test voltage 125V/250V/500V/1000V 50V/125V/250V/500V
Measuring ranges 20MΩ/50MΩ/100MΩ/2000MΩ 10MΩ/20MΩ/50MΩ/100MΩ
Mid-scale value 0.5MΩ/1MΩ/2MΩ/50MΩ 0.2MΩ/0.5MΩ/1MΩ/2MΩ
First effective 0.02~10MΩ/0.05~20MΩ/ 0.01~5MΩ/0.02~10MΩ/
measuring ranges 0.1~50MΩ/2~1000MΩ 0.05~20MΩ/0.1~50MΩ
Accuracy ±5% of indicated value
MODEL

Second effective 10~20MΩ/20~50MΩ/ 5~10MΩ/10~20MΩ/


measuring ranges 50~100MΩ/100~2000MΩ 20~50MΩ/50~100MΩ
Accuracy ±10% of indicated value
3315/3316

AC voltage
AC voltage range 600V
Accuracy ±5% of full scale value
Applicable standards IEC 61010-1 CAT.3 600V, CAT.21000V
Withstand voltage 5550V AC for 1 minute
Power source R6P(AA)(1.5V) × 6
Dimensions 105(L) × 158(W) × 70(D)mm
Weight 520g approx.
Accessories 7150(Test lead with remote control switch set)
7081(Guard cord):3315 only
9121(shoulder strap)
R6P(AA) × 6
Instruction manual
Optional 7115(Extension probe)
8016(Pickel type prod)
photo : 3315 9089(Carrying case)
• 4 test voltages plus AC voltage range.
• Colour coded scales and range switch position for easy reading.
• Test leads with remote control switch .
• New robust housing case.
• Back light function.
• Neck strap for both hand’s operation.

30
KEW ANALOGUE INSULATION TESTERS
MODEL 3321A/3322A/3323A
MODEL 3321A MODEL 3322A MODEL 3323A
Insulation resistance
DC test voltage 250V/500V/1000V 125V/250V/500V 25V/50V/100V
Measuring ranges 50MΩ/100MΩ/2000MΩ 20MΩ/50MΩ/100MΩ 10MΩ/10MΩ/20MΩ
Mid-scale value 1MΩ/2MΩ/50MΩ 0.5MΩ/1MΩ/2MΩ 0.2MΩ/0.2MΩ/0.5MΩ
First effective 0.05~20MΩ(250V) 0.02~10MΩ(125V) 0.01~5MΩ(25V)
measuring ranges 0.1~50MΩ(500V) 0.05~20MΩ(250V) 0.01~5MΩ(50V)
2~1000MΩ(1000V) 0.1~50MΩ(500V) 0.02~10MΩ(100V)
Accuracy ±5% of indicated value
Second effective 20~50MΩ(250V) 10~20MΩ(125V) 5~10MΩ(25V)
measuring ranges 50~100MΩ(500V) 20~50MΩ(250V) 5~10MΩ(50V)
1000~2000MΩ(1000V) 50~100MΩ(500V) 10~20MΩ(100V)
Accuracy ±10% of indicated value
AC voltage
AC voltage range 600V
Accuracy ±3% of full scale value
Applicable standards IEC 61010-1 CAT.3600V, CAT.21000V
Withstand voltage 5550V AC for 1 minute
Power source R6P(AA)(1.5V) × 6
Dimensions 105(L) × 158(W) × 70(D)mm
Weight 520g approx.
Accessories 7150(Test lead with remote control switch set)
9121(Shoulder strap)
7081(Guard cord):3321A only
R6P(AA) × 6 Instruction manual
Optional 7115(Extension probe) 8016(Pickel type prod)
9089(Carrying case)
photo : 3321A

• AC Voltmeter with linear, easy-to-read scales. Selection Guide


• Auto discharge function; any charge stored in the circuit under test will be MODEL 3321A MODEL 3322A MODEL 3323A
automatically discharged after testing. Test voltage 250V 125V 25V
• Designed to meet IEC 61010-1 CAT.3 600V, CAT.2 1000V 500V 250V 50V
• Color-coded scales for easy reading. 1000V 500V 100V
• Back light function to facilitate working at dimly illuminated locations. Illuminated scale
• Test lead set with remote control switch. Automatic discharge
• Shoulder strap for hands free. Remote control switch

3321A/3322A/3323A
Accessories Optional Accessories
7149
(7139)
MODEL 3144A, 3145A, 3146A, 3161A

7150
(7103)
MODEL 3315, 3316, 3321A, 3322A, 3323A
KEW 3021, 3022, 3023

7116 7115
MODEL

MODEL 7115/7116 Extension probe

MODEL 7149/7150 Test lead with control remote switch set


(7103 or 7139, 7161, 7131, 8017, 9120 or 9041)

MODEL 8016 Pickel type prod MODEL 9089 Carrying case


MODEL 7122A Test leads MODEL 7025 Test leads
MODEL 3005A, 3007A, 3131A, 3132A MODEL 3001B, 3111V, 3165, 3166

31
KEW INSULATION TESTERS
Why insulation test is necessary?
All live conductors of electrical Nominal circuit voltage Test voltage insulation resistance
appliances and installations (V) V DC (Mohms)
must be insulated to prevent SELV and functional extra-low voltage, when the circuit is supplied from 250 ≥0.25
a safety isolating transformer
electric shock hazards from
(SELV:Safety extra-low voltage)
inadver tent contact, f ire Up to and including 500V with the exception of the above cases 500 ≥0.5
hazards from short circuit
and equipment damage. In Above 500V 1000 ≥1.0
addition, a low insulation
resistance in installation will
Minimum value of insulation resistance by IEC364-6-61 TABLE 61A
result in a leakage current, and
hence causes a waste of energy which would increase the running costs of the installation.
Insulation resistance must be checked by applying appliances or installations a higher voltage than its normal working voltage,
because an insulation resistance is lower at higher voltage than at lower voltage. KYORITSU’s insulation resistance testers provide
measurement at high levels of test voltages.
Periodical test is also important to ensure that insulation of installations or appliances is not deteriorating. Foreign matter and
mechanical factors like wear or breakage may reduce insulation resistance. Regular tests and data logs can detect possible fault
in insulation.

Insulation Testing Methods


■Measurement of Insulation resistance
between live conductors (A)
Prior to testing, make sure that the circuit
or part of the installation to be tested
is disconnected from the mains supply
and not energized. It is also necessary to
ensure: the point of the installation to be
checked is not open due to other equipment
incorporated, the load connected with a
fixed load and socket outlet is disconnected
from the mains supply, and relay coils,
fluorescent lamps, etc do not produce
continuity between conductors. Circuits
or components likely to be damaged by
insulation test voltage must be removed
from the circuit under test. If they cannot be
disconnected, an alternative testing method
is to measure insulation resistance between B
live conductors and earth.

■Measurement of insulation resistance


between live conductors and earth (B)
The test must be carried out with equipment
always disconnected, i.e., with the mains
switch open it must be disconnected from
the mains supply. Earth terminal must be A
connected to earth and Line terminal to a
A - Between live conductors
live conductor or conductors.Where there B - Between live conductors and earth
is insulation deterioration or an indoor
electrical installation is not partly or totally
insulated a variety of electric hazards may
be anticipated.

To give some of the examples;


•Leakage current dangerous to the human body will develop.This is particularly the case with equipment that has no good earth
and therefore is not properly protected against the potential difference.
•Overheating of conductors due to the leakage of current or microscopic discharging will cause short circuits or fires.
•RCDs will trip, with resulting damage to the equipment which will also cause short circuits and fires.

Kyoritsu’s dedicated leakage clamp meters Model 2412, 2413F, 2417, 2431, 2432, 2433, 2433R and 2434 will be very
helpful in identifying the possible causes of such accidents.

32
KEW HIGH VOLTAGE INSULATION TESTERS
Model 3120 series is our range of high voltage insulation testers covering a rated test voltage range from
2500V to 10000V. They feature an extremely compact design due to the employment of high performance
electronic circuit and a wide, dual scale for easy reading.

MODEL 3121/3122/3123
MODEL 3121 MODEL 3122 MODEL 3123

DC test voltage 2500V 5000V 5000V 10000V


Measuring ranges 2GΩ/100GΩ 5GΩ/200GΩ 5GΩ/200GΩ 10GΩ/400GΩ
(automatic change) (autoranging) (autoranging) (autoranging) (autoranging)
First effective 0.1~50GΩ 0.2~100GΩ 0.2~100GΩ 0.4~200GΩ
measuring ranges
accuracy ±5% rdg
Other ranges accuracy ±10% rdg or 0.5% of scale length
Withstand voltage 5000V AC for 1 minute
Power source R6P(AA)(1.5V) × 8
Dimensions 200(L) × 140(W) × 80(D)mm
Weight 1kg approx.
Accessories 7058(Test leads) 7058(Test leads)
9039(Carrying case[Hard]) 9039(Carrying case[Hard])
R6P(AA) × 8 8019(Pickel type prod)
Instruction manual R6P(AA) × 8 Instruction manual
Optional 8019(Pickel type prod) 8020(Adaptor for recorder)
8020(Adaptor for recorder)

• Dual scales for low and high ranges which change automatically. Colour
coded scales for easy reading plus LED’s that illuminate in matching colour.
• Drip proof construction.
• Hard carrying case furnished as standard accessory.
• Designed for low power consumption.

3124
MODEL 3124

DC test voltage 1k~10kV variable 1000V


MODEL Measuring ranges 1.6GΩ/100GΩ 100MΩ
(automatic change) (autoranging)
First effective 0.05~50GΩ 1~100MΩ
measuring ranges
accuracy ±10% rdg
Other ranges accuracy ±1% of scale length

3121/3122/3123
Output voltage and DC 0~10kV
set voltage indicate ±2%rdg±2dgt
With stand voltage 5000V AC for 1 minute
Power source Ni-Cd rechargeable battery(1.2V) × 8
Dimensions 200(L) × 140(W) × 80(D)mm
Weight 1.5kg approx.
Accessories 7082(Lead for recorder) 7083(Lead for battery charging)
7084(Earth and guard leads)
8079(Battery charger[120V]) or 8080(Battery charger[220V])
9112(Carrying case[Hard])
Ni-Cd rechargeable battery × 8 Instruction manual

Optional Accessories
MODEL

•Permits a wide range of insulation testing up to 100GΩ at variable test


voltage from 1kV to 10kV.
•DC voltage output for recorders.
•Output voltage is shown on the digital display.
•After tests, automatically discharges the charges stored in the circuit MODEL 8019
Pickel type prod
under test.
•Operated by rechargeable Nickel-Cadmium batteries.
3124

Selection Guide
MODEL 3121 MODEL 3122 MODEL 3123 MODEL 3124
MODEL

2500V test voltage


5000V test voltage
10000V test voltage
MODEL 8020
1k-10kV variable test voltage Adaptor for recorder (10mV/1mA)
Dual resistance scales Connector side : 200mm
Recorder output Alligator clip side : 1100mm
Guard terminal
33
KEW HIGH VOLTAGE INSULATION TESTER
MODEL 3125 HIGH VOLTAGE INSULATION TESTER

• Wide range measurements from 500V to


5000V and up to 1000GΩ.
• Large digital display with bar graph indi-
cation and back light.
• Polarization index measurement (PI).
• Timer measurement function.
• Indication of output voltage and dis-
charge voltage.
• Auto-discharge function and voltage out-
put warning function.
• Auto power off and battery check.
• Safety standard IEC61010-1 CAT. 3 600V MODEL 9124
Carrying case[Hard]

MODEL 3125

Range Insulation resistance Voltage measurement


500V 1000V 2500V 5000V AC/DC V
Measuring range 0.0~99.9MW 0.0~99.9MW 0.0~99.9MW 0.0~99.9MW 30~600V
100~999MW 100~999MW 100~999MW 100~999MW AC/DC
1.00~1.99GW 1.00~9.99GW 1.00~9.99GW (50/60Hz)
10.0~99.9GW 10.0~99.9GW
100~1000GW(1TW)
Accuracy ±5%rdg±3dgt ±5%rdg±3dgt ±5%rdg±3dgt ±5%rdg±3dgt ±2%rdg±3dgt
±20%(100GW or more)
Short circuit current 1.3mA approx.
Rated test current 1mA~1.2mA at 0.5MW load 1mA~1.2mA at 1MW load 1mA~1.2mA at 2.5MW load 1mA ~1.2mA at 5MW load
Open circuit voltage 500VDC+30% 1000VDC+20% 2500VDC+20% 5000VDC+20%
-0% -0% -0% -0%
Maximum display 999 Counts(1000 counts only at 1000GW) 630 Counts
Current consumption About 1000mA(During measurement) 110mA approx.
MODEL

Withstand voltage 5320V AC for 5 seconds


Applicable standards IEC 61010-1 CAT.3 600V Pollution degree 2
Power supply DC12V : R14 × 8
3125

Dimensions 205(L) × 152(W) × 94(D)mm


Weight 1.8kg approx.
Accessories 7165(Line probe) 7166(Earth cord) 7167(Guard cord) LR14(Alkaline battery size C) × 8 Instruction manual
9124(Carrying case[Hard]) 8019(Pickel type prod)
Optional 7168(Line probe with alligator clip) 8302(Adaptor for recorder)

Optional Accessories

MODEL 7168 MODEL 8302


Line probe with alligator clip : 3000mm Adaptor for recorder (Output 1mV/1μA)
Connector side : 200mm
Alligator clip side : 1100mm

Polarization Index
Polarization Index is one of the factors to check the condition of insulation.
The polarization Index is defined as the ratio between the resistance value in 10 minutes and the resistance value in 1 minute after switch is on.

Calculation formula : MODEL 3125 Output characteristics


Polarization Index = resistance value in 10 minutes (TIME2) / resistance value in 1 minute (TIME1) 6000

5000
Setting interval is as follows.
TIME1 00:05~59:30
Out put Voltage(V)

4000

TIME2 00:10~60:00 (Remarks : 00:10 means 10 seconds)


3000

Since polarization Index varies with moisture absorption regardless of the shape or size of 2000
insulator, it gives significant criteria to verify the insulation. Following table shows the criteria.
1000

Polarization index 4 or more 4.0~1.5 1.5~1.0 1.0 or less


Criteria Very good Good Dubious Unsatisfactory 0
0.0001 0.001 0.01 0.1 1 10 100 1000
Insulation Resistance(GΩ)

34
KEW HIGH VOLTAGE INSULATION TESTER
KEW 3128 HIGH VOLTAGE INSULATION TESTER
KEW3128 is a Microprocessor controlled high voltage insulation
resistance tester with Diagnostic functions. It has 6 ranges: 500V,
1000V, 2500V, 5000V, 10000V, 12000V and can measure up
to 35TΩ. It is suitable for analyzing the insulation characteristics
of cables, transformers, motors, generators, high-pressure switches,
insulators, wiring installations, etc. It is also useful for predictive main-
tenance by storing results in PC and trend analysis.
Measured results can be saved in the internal memory; they can be
transferred to a PC via a special USB cord. Measuring data can also
be transferred to a PC in real-time.

• Test Voltage 12kV (max), Resistance 35TΩ (max), Short-Circuit Current


5mA (max).
• Graphic representation of the insulation resistance and leakage current
versus time on large display with bar graph and backlight.
• Print Screen Function enables to record up to 32 display screens.
• Internal Memory can store about 40,000 data (max).
•Automatic discharge after test and display of discharge voltage.
• Fine adjustment of voltage setting at each range is also possible.
• Can be operated from internal rechargeable battery or from AC line.
• Robust design for field use with IP64 rating (with lid closed).

Function
• Insulation Resistance (IR) & Leakage current..
• Polarization Index (PI).
• Dielectric Absorption Ratio (DAR).
• Dielectric Discharge Index (DD).
• Step Voltage (SV).
• Capacitance of the object under test.

KEW 3128
Insulation resistance
Rated voltage 500V 1000V 2500V 5000V 10000V 12000V
Max measurement value 500GW 1TW 2.5TW 5TW 35TW
0~50GW 0~100GW 0~250GW 0~500GW 0~1TW
±5%±3dgt ±5%±3dgt ±5%±3dgt ±5%±3dgt ±5%±3dgt

3128
1T~10TW
Accuracy
50G~500GW 100G~1TW 250G~2.5TW 500G~5TW ±20%
±20% ±20% ±20% ±20% 10T~35TΩ
Values are displayed, but accuracy isn’t guaranteed

KEW
Short circuit current Max 5.0mA
1mA or more,
1mA or more, 1mA or more, 1mA or more, 1mA or more, 1mA or more,
1.2mA or less under
Rated test current 1.2mA or less under 1.2mA or less under 1.2mA or less under 1.2mA or less under 1.2mA or less under
a load of 0.5MW
a load of 1MW a load of 2.5MW a load of 5MW a load of 10MW a load of 12MW
*Should be 500V or more
Output voltage
Rated voltage 500V 1000V 2500V 5000V 10000V 12000V
Monitor accuracy ±10%±20V ±10%±20V ±10%±20V ±10%±20V ±10%±20V ±10%±20V
Output accuracy 0~+20% 0~+10% 0~+10% 0~+10% -5~+5% -5~+5%
50~600V 610~1200V 1225~3000V 3050~6000V 6100~10000V 10100~12000V
Selectable range
(in steps of 5V) (in steps of 10V) (in steps of 25V) (in steps of 50V) (in steps of 100V) (in steps of 100V)
Voltage measurement
Measuring range DCV : ±30~±600V, ACV : 30~600V(50/60Hz)
Accuracy ±2%rdg±3dgt
Current measurement
Measuring range 5.0nA~5.00mA
Accuracy ±5%rdg±5dgt
Capacitance measurement
Measuring range 5.0nF~50.0μF (Under 10kV: Upper limit 50.0μF, 10kV or more: Upper limit 5.00μF)
Accuracy ±5%rdg±5dgt
General
AC8770V : between line terminal and enclosure /5sec (50/60Hz)
Withstand voltage AC6880V : between the measuring terminal and enclosure /5sec (50/60Hz)
AC2330V : between the power connector and enclosure /5sec (50/60Hz)
Applicable standards IEC 61010-1 CAT.4 600V Pollution degree 2, IEC 61010-031, IEC 61326, IEC 60529(IP64): with the lid closed.
Rechargeable Lead storage battery (12V) / AC Power supply (100V~240V, 50/60Hz)
Power source ※Continuous measuring time: approx. 4 hours (Battery voltage : representative values with battery voltages 10.0V or
more applying a load of 100MW at the Insulation resistance 12000V Range.)
Dimensions 330(L) × 410(W) × 180(D)mm ※Instrument and Hard case
Weight 9kg approx. (including battery) ※Instrument and Hard case
7226(Line probe), 7224(Earth cord), 7225(Guard cord), 7170(Main cord), 8029(Extension prod)
Accessories
8212-USB-W(USB adaptor with KEW Windows(Software)), Instruction manual
Optional 7227(Line probe with alligator clip)

35
KEW HIGH VOLTAGE INSULATION TESTER
Measuring data can be transferred to a PC in real-time.
IR Measurement PC screen
Graphic representation of the leakage
current versus time on display

SV Measurement PC screen

PI Measurement PC screen

DD Measurement (Dielectric Discharge)


DD : Dielectric Discharge Current value 1 min after
This measurement method is usually used to diagnosis multi-layer completing measurement (mA)
insulations, which requires the instrument to measure the discharge Dielectric Discharge=
current and capacitance of the measured object 1 min after the Voltage value when a measure-
removal of the test voltage. This is a very good diagnostic insula- ment complete x Capacitance (F)
tion test that allows deterioration and other problems voids in the
multiple insulations to be assessed.

*This criteria is a guide and could be slightly changed and be adapt-


ed to particular objects under test based on practical experience of
the users.
DD 2.0 or less 2.0~4.0 4.0~7.0 7.0 or more *This method has been established to test high voltage generators
Criteria Good Warning Poor Very Poor installed in electric power plants in the Europe countries.

DAR Measurement (Dielectric Absorption Ratio)


KEW

DAR : Dielectric Absorption Ratio


TIME2
DAR measurement is a Time/Resistance test method similar to the Insulation resistance value 30 sec or
3128

Polarization Index (PI), but DAR takes the ratio of the insulation 1 min after starting measurement
usually measured at 1 minute and 30 seconds instead of 10 min- Dielectric =
utes and 1 minute typically of the PI. DAR and PI measurements Absorption Ratio TIME1
are useful because they can be used to eliminate the influence of Insulation resistance value
temperature, humidity and leakage currents likely to invalidate the 15 or 30 sec after starting measurement
“absolute” insulation resistance measurement.
DAR 1.4 or less 1.25~1.0 1.0 or less
Criteria Best Good Bad

SV Measurement (Step Voltage)


SV : Step Voltage
This is a test based on the principle that an ideal insulation will produce identical readings at all voltages, while an insulation which is be-
ing over stressed, will show lower insulation values at higher voltages. During the test, the applied voltage incrementally steps by a certain
voltage taking successive 5-time measurement. Degradation of insulation may be doubt when insulation resistances become lower at
higher applied voltages.

Accessories

"KEW Windows" Software for report
The stored data can be transferred to PC via
MODEL8212-USB.

System Requirements
• OS (Operation System)
Windows® 2000/XP/VISTA(CPU: Pentium 3 800MHz or higher)
• Memory
256Mbyte or more. ❈ Trade mark
®
Windows is a registered trade
• Display mark of Microsoft in the United
MODEL 8212-USB-W Resolution 1024 × 768 dots, 65536 colors or more.
• HDD (Hard-disk) space required
States.
❈ Pentium is a registered trade
USB adaptor with “KEW Windows (Software)” 100Mbyte or more. mark of Intel in the United
❈Please refer to P51 for the specification of USB adaptor (Model 8212-USB). • NET Framework (2.0 or later) States.

36
KEW EARTH TESTERS
The Kyoritsu's range of earth resistance testers have been enjoying worldwide popularity and longtime
sales as a high quality and high performance test instrument. Our original constant current circuit to
minimize the effect of commercial frequencies and a synchronous rectifying circuit always ensure a stable
instrument performance. Advanced functions include self-check of the resistance of auxiliary earth spikes
and testing of earth voltage, etc. All of these features ensure trouble free operation in the field.

4102A
MODEL 4102A/4102A-H

Measurement Earth resistance : 0~12Ω /0~120Ω /0~1200Ω


MODEL ranges Earth voltage[50,60Hz] : 0~30V AC
Accuracy Earth resistance: ±3% of full scale
MODEL 4102A Soft case model Earth voltage: ±3% of full scale
MODEL 4102A-H Hard case model Overload protection Earth resistance : 276V AC for 10 seconds
across 2 of the 3 terminals
Earth voltage : 276V AC for 1 minute
Applicable standards IEC 61010-1 CAT.3 300V Pollution degree 2 IEC 61557-1,5
IEC 61010-031 IEC 60529(IP54)
Withstand voltage 3700V AC for 1 minute
Power source R6P(AA)(1.5V) × 6
Dimensions 105(L) × 158(W) × 70(D)mm
Weight 600g approx.
Accessories 7095(Test leads for earth resistance) × 1set(red-20m, yellow-10m,
green-5m) 8032(Auxiliary earth spikes) × 1set
7127(Simplified measurement probe) × 1set
R6P(AA) × 6, 9121(Shoulder strap), Instruction manual
Carrying case : 9084(Carrying case[Soft])
: 9106(Carrying case[Hard])
Optional 7100(Precision measurement cord set)

4102A
MODEL 4102A Soft case model

MODEL
• The latest circuit design permits the instrument to operate with the mini-
mum of influence from earth voltage and earth resistance of auxiliary
earth spikes.
• Dust and drip proof. (designed to IEC 529 IP54)
• Earth resistance value can be read directly from the scale.
• Designed to meet IEC61010-1 safety standard.
• Capable of measuring earth voltage.
• Small and lightweight. Shock resistant new case material.
• 2mA measuring current permits earth resistance tests without tripping
earth leakage current breakers in the circuit under test.
• Lead wire connection to C and P terminals and proper auxiliary earth
resistance can be checked by “OK” lamp. Lead wire connection to C and
E terminals is good when “OK” lamp is illuminated. MODEL 4102A-H Hard case model

Simplified Measurement Precise Measurement


(with Test lead M-7127) (with Test lead M-7095)

Indicated
Value

Be sure to check
earthed side of a
commercial power supply.

37
KEW EARTH TESTERS
4105A
MODEL 4105A/4105A-H

Measurement Earth resistance : 0~20Ω /0~200Ω /0~2000Ω


MODEL ranges Earth voltage(50,60Hz) : 0~200V AC
Accuracy Earth resistance : ±2%rdg±0.1(20Ω range)
MODEL 4105A Soft case model ±2%rdg±3dgt(200/2000Ω range)
MODEL 4105A-H Hard case model Earth voltage : ±1%rdg±4dgt
Overload protection Earth resistance : 280V AC for 10 seconds
across 2 of the 3 terminals
Earth voltage : 300V AC for 1 minute
Applicable standards IEC 61010-1 CAT.3 300V Pollution degree 2 IEC 61557-1,5
IEC 61010-031 IEC 60529(IP54)
Withstand voltage 3700V AC for 1 minute
Power source R6P(AA)(1.5V) × 6
Dimensions 105(L) × 158(W) × 70(D)mm
Weight 550g approx.
Accessories 7095(Test leads for earth resistance ) × 1set(red-20m, yellow-10m, green-5m)
8032(Auxiliary earth spikes) × 1set
7127(Simplified measurement probe) × 1set
R6P(AA) × 6, 9121(Shoulder strap), Instruction manual
Carrying case : 9084(Carrying case[Soft])
: 9106(Carrying case[Hard])
Optional 7100(Precision measurement cord set)

• Dust and drip proof.(designed to IEC 529 IP54)


• In addition to the facility for precision measurement, test leads for simpli-
fied two wire measuring system also supplied as standard accessories.
(unit can be hung from the neck for simplified measurement)
• Designed to meet IEC61010-1 safety standard.
• Capable of measuring earth voltage.
• Automatic warning when resistance of auxiliary earth spikes is in excess
MODEL

of tolerance.
• Small and lightweight. Shock resistant new case material. MODEL 4105A Soft case model
• 2mA measuring current permits earth resistance tests without tripping
4105A

earth leakage current breakers in the circuit under test.

Accessories

MODEL 7095 MODEL 8032 MODEL 7127


MODEL 4105A-H Hard case model

Precise Measurement (with Test lead M-7095) Simplified Measurement (with Test lead M-7127)

Indicated
Value

Be sure to check
earthed side of a
commercial power supply.

38
KEW EARTH TESTERS
4106
KEW 4106

Function Range Resolution Measuring range Accuracy


KEW 2W 0.001W 0~2.099W ±2%rdg.±0.03W
20W 0.01W 0~20.99W
Earth resistance
200W 0.1W 0~209.9W
Re
2000W 1W 0~2099W ±2%rdg.±5dgt*1
(Rg at ρ measurement)
20kW 10W 0~20.99kW
200kW 100W 0~209.9kW
Auxiliary earth resistance Rh, Rs 8% of Re+Rh+Rs
2W 0~395.6W·m
20W 0~3956W·m
200W 0.1W·m~1W·m 0~39.56kW·m
Earth resistivity ρ ρ=2×π×a×Rg*2
2000W Autoranging 0~395.6kW·m
20kW
0~1999kW·m
200kW
Series interference voltage Ust (A.C only)*3 200V 0.1V 0~50.9Vrms ±2%±2dgt
Frequency Fst Autoranging 0.1Hz, 1Hz 40Hz~500Hz ±1%±2dgt
Earth resistance : Fall-of-potential method
(currents and voltages measured via the Probes)
Measuring method
Series interference voltage (erath voltage):
RMS Rectifier (between the E-S Terminals)
Test Current 80mA(max)
Memory capacity 800 data
Communication interface Model 8212-USB Optical Adaptor
LCD Dot-matrix 192 × 64, monochrome
Over-range indication “OL”
KEW4106 is a 2/3/4 Wire Earth Resistance & Resistivity Tester Overload protection between E-S(P) and between E-H(C) terminals AC280V / 10 sec
designed for measuring Earth resistances and calculates the soil Withstand voltage
between the electrical circuit and enclosure
Earth Resistivity (ρ). This instrument is ideal for Earth measurements AC3540V(50/60Hz) / 5 sec
also in large Earthing systems because uses a considerable test IEC 61010-1 CAT.3 300V, CAT.4 150V Pollution degree 2
Applicable standards
IEC 61010-031, IEC 61557-1,5, IEC 61326-1(EMC), IEC 60529(IP54)
Current of 80mA (max) yielding a high resolution of 1mΩ on 2Ω
DC12V : sizeAA manganese dry battery (R6P) x 8
range. (Auto power off: approx. 5 minutes)
Power source
The Earth Resistivity measurement is useful for soil surveys to estab- *In a use of this instrument under low temperature below 0ºC, a use of
alkaline batteries with low temperature spec is recommended.
lish the optimum earth electrode system design and site, to avoid Dimensions 167(L) × 185(W) × 89(D)mm
extra cost of re-working electrode installations. It can be also suit- Weight approx. 900g (including batteries)
able for geological investigations. 7229(Precision measurement test leads),
7238(Simplified measurement test leads)
• Earth resistance measurement with six ranges covering measurements 8032(Auxiliary earth spikes)×2,
from 0.001 Ω to 200 kΩ. Accessories 8200-04(Cord reels [4pcs]),
• Earth resistivity measurement is automatically calculated after having 8212-USB(USB adaptor with “KEW Report(Software)”)*4

4106
set the distance between Auxiliary Earth Spikes (Wenner method). 9121(Shoulder strap), 9125(Carrying case)
• Automatic and Manual selection of the Test Current Frequency in four R6P×8, Instruction manual
bands of 94/105/111/128Hz. In Automatic mode KEW 4106 will Optional 8212-RS232C(RS232C adaptor with “KEW Report(Software)”)*4
select the most suitable Frequency.
*1: Auxiliary earth resistance is 100Ω with Rk correction

KEW
• Advanced Filtering method (based on FFT Fast Fourier Transform) re-
*2: Depending on the measured Rg. Interval [a] between auxiliary earth spikes is 1.0~30.0m
duces noise interference for obtaining stable measurements. *3: This instrument is NOT designed to measure voltages on commercial powers.
• Several sub-results can be shown on the display: Resistance of the *4: Please refer to P51 for the specification.
Auxiliary Earth Spikes, Frequency of Test Current, Voltage and Fre-
quency of the Interference (noise), Residual Resistance Rk, etc.
• Warning for excessive noise and high Auxiliary Earth Spikes resistance.
• Null facility eliminates the residual test lead resistance (Rk) to ensure more accurate low Earth Resistance measurements.
• Large Graphic Display with backlight for readings in poorly illuminated areas.
• Up to 800 measurement results can be saved in the memory and recalled on the display.
• The stored results can be transferred to a PC via USB adaptor (Model 8212-USB) by using software “KEW Report” which are included.
• Robust design with IP54 protection.

Principle of Earth Resistivity (ρ) Measurements


According to the Wenner 4-pole method, apply AC current “I” be-
tween the “E” (earth electrode) and“ H(C)” (current electrode) to find
out the potential difference “V” between the potential electrode “S(P)”
and auxiliary earth electrodes“ ES”.
To obtain the earth resistance“ Rg (Ω)”, devide the potential differ-
ence“ V” by AC current“ I”; where the interval between electrod-
eds is“ a”(m). Then use a formula: ρ= 2 π a Rg (Ωm)

39
KEW EARTH CLAMP TESTER
MODEL 4200 EARTH CLAMP TESTER
MODEL 4200
Function Range ResolutionMeasuring range Accuracy
Earth resistance 20Ω 0.01(Ω) 0.00~20.99(Ω) ±1.5%±0.05Ω
Auto range 16.0~99.9(Ω) ±2%±0.5Ω
200Ω 0.1(Ω)
100.0~209.9(Ω) ±3%±2Ω
160~399(Ω) ±5%±5Ω
1(Ω)
1200Ω 400~599(Ω) ±10%±10Ω
RMS 10(Ω) 600~1260(Ω) –
AC current 100mA 0.1(mA) 0.0~104.9(mA) ±2%±0.7mA
[50Hz / 60Hz] 1000mA 1(mA) 80~1049(mA)
Auto range 10A 0.01(A) 0.80~10.49(A) ±2%
30A 0.1(A) 8.0~31.5(A)
Operating system Earth resistance function : Constant voltage injection
Current detection (Frequency : Approx.2400Hz)
Dual Integration
AC current function : Successive approximation
Over-range indication "OL" is displayed when input exceeds the upper limit of a measuring range
Response time Approx. 7 seconds(Earth resistance) Approx. 2 seconds(AC current)
Sample rate Approx. 1 times per second
Power source DC6V : R6P(sizeAA manganese battery) × 4 or LR6(sizeAA alkaline battery) × 4
Current consumption Approx. 50mA (max. 100mA)
Measurement time Approx.12 hours (when R6P is used) Approx. 24 hours (when LR6 is used)
Auto power-off Turns power off about 10 minutes after the last button operation.
Applicable standards IEC 61010-1 CAT.4 300V Pollution degree2
IEC 61010-2-032, IEC 61326(EMC)
Withstand voltage AC5320Vrms / 5 seconds
Between the Transformer jaws fitted parts and case enclosure (except for jaws)
Conductor size Approx. φ32mm
Dimension 246(L) × 120(W) × 54(D)mm
Weight Approx. 780g (including batteries)
Accessories R6P × 4 Instruction manual
8304(Resister for operation check) 9128(Carrying case[Hard])
Note: A single earthing can not be measured. (only for Multiple Earting system.)
Crest factor 3 (50Hz / 60Hz, peak value shall not exceed 60A) 4 counts or less are corrected to 0.

• The earth resistance from 0.05 to 1200Ω can be measured without the auxiliary earth spikes.
(The Multiple Earthing System.)
Accessories
• True RMS
Accurate true RMS readings of AC current including distorted waveform from 1mA to 30.0A
MODEL

• Noise Check Function


A function to detect current, which effects on an earth resistance measurement and display “NOISE”
mark on the LCD.
4200

• Memory function
Save and display up to 100 measurement data.
• Data hold function / Buzzer function / Back light function
• Compliant with Safety Standards of IEC 61010-1 : CAT.4 300V Pollution degree2

1Ω loop 10Ω loop

Why earth measurements can be found by only clamping it?


Rx, is defined as earth These earth resistances, R1, R2,… Rn
resistance under test, and can be considered that they are connected
R1, R2…Rn are defined as in parallel.
earth resistance of other And They can be regarded as a combined
measuring objects. resistance Rs. The Rs can be regarded
small enough against Rx since a combined MODEL 8304
Rx resistance consists of several resistances. Resistor for operation check
Rx Following is an equiva- 1
lent circuit diagram of Rs= n
1
this circuit. Σ i=1 Ri

Rx R1 Rn Rx R1 R2 Rn Rx Rs

I
Voltage V is applied to the object (Resistance Rx) V
measured from the voltage injection transformer = R = Rx + Rs
I CT1
CT1, and the current I corresponding to the earth V
resistance is flowed. 1
Rx 〉〉Rs= n CT2
1
The current I is detected with detection transformer
CT2, and object (Resistance Rx) measured can be Σi=1Ri

put out by the calculation. (refer to the right diagram) V


= Rx
Rx Rs MODEL 9128
I Carrying case[Hard]

40
KEW LOOP/PSC TESTERS
In the event of earth circuit being overloaded or shorted the likely result is that a sufficient current
does not flow into the circuit where a loop resistance is too high, causing circuit breaker, earth leakage
breaker and other protection devices to become inoperative. To prevent such a possible accident we must
check the earth circuit for its correct resistance and keep it as low as required.

4116A/4118A
• Custom microprocessor controlled for highest accuracy and reliability.
• 3 LEDs for checking correct wiring status.
MODEL • 15mA LOOP measurement:LOOP impedance 2000W range measure-
ment is carried out with low test current (15mA). The current will not
cause tripping out involved RCD even the one with the lowest nominal
differential current (30mA).
• Direct reading of Prospective Short Circuit Current (PSC). (Model
4118A only)
• Safe voltage measurement function.
• Large custom digital display readout on all models.
• Measure low loop resistances(resolution of 0.01W)
• Automatic lock-out if test resister overheats.
• Large custom digital display readout .
• Visual indication of reversed phase and neutral wiring at socket.
• Designed to IP54 Rating
• Complies with IEC61557

MODEL 4116A MODEL 4118A

Loop impedance 20/200/2000Ω 20/200/2000Ω


ranges
Loop impedance ±2%rdg±4dgt ±2%rdg±4dgt
accuracy
AC test current 20Ω 25A 20Ω 25A
200Ω 2.3A 200Ω 2.3A
2000Ω 15mA 2000Ω 15mA
AC test period 20Ω (20ms) 20Ω (20ms)
200Ω (40ms) 200Ω (40ms)
2000Ω (280ms) 2000Ω (280ms)
PSC ranges 200A(2.3A 40ms)
2000A(25A 20ms)
20kA(25A 20ms)

4116A/4118A
PSC ranges accuracy Consider accuracy
of loop impedance
Voltage 110V~260V ±2%rdg±4dgt

Front Cover Operating voltage


Applicable
230V +10%, -15%(195V~253V)50Hz
IEC 61010-1 CAT.3 300V IEC 61557-1,3
standards IEC 61010-031 Pollution degree 2 IEC 60529(IP54)
Dimensions 185(L) × 167(W) × 89(D)mm
Weight 750g approx.
Accessories Molded plug test leads Molded plug test leads
9147(Card case) 7121A(Distribution board test leads)

MODEL
9121(Shoulder strap) 9147(Card case)
Instruction manual 9121(Shoulder strap)

Selection Guide Optional 7121A(Distribution board test leads)


Instruction manual

MODEL 4120A MODEL 4116A MODEL 4118A

LOOP test range


PSC test range
Automatic RCD lock circuit
Display mains voltage before test
Visual indication of correct wiring status
Lock down test button for continuous
operation
15mA LOOP measurement
(2000Ω range)

Accessories

Molded plug test leads


MODEL 7123 (AU)Australian plug

MODEL 7124 (UK)British plug(13A)


MODEL 7121A
MODEL 7125 (EU)European SHUKO plug
(Distribution board test leads)
4118A, 4120A MODEL 7126 (SA)South african plug

41
KEW LOOP/PSC TESTERS
Model 4120A series is a very convenient test instrument
MODEL 4120A capable of measuring fault loop impedance within the wiring
circuit directly at the power outlet. It is widely used in EUROPE.
Model 4118A and 4120A can also measure prospective
short circuit current. One of the outstanding features of Model
4120A is a new D-Lok circuit that permits loop impedance
testing without tripping out the RCDs(ELCBs) installed in the
circuit under loop testing.
MODEL 4120A

Loop impedance 20/200/2000Ω (20/200Ω D-LOK)


ranges
Loop impedance ±2%rdg±4dgt
accuracy
AC test current 20Ω 25A 200Ω 2.3A
2000Ω 15mA
AC test period 20Ω (20ms) 200Ω (40ms)
2000Ω (280ms)
PSC ranges 200A(2.3A 40ms) 2000A(25A 20ms) D-LOK
20kA(25A 20ms) D-LOK
PSC ranges accuracy Consider accuracy of loop impedance
Voltage 110V~260V ±2%rdg±4dgt
• Custom microprocessor controlled for highest accuracy and reliability. Operating voltage 230V +10%, -15%(195V~253V)[50Hz]
• 3 LEDs for checking correct wiring status. Applicable standards IEC 61010-1 CAT.3 300V IEC 61557-1,3
• 15mA LOOP measurement:LOOP impedance 2000Ω range measure- IEC 61010-031 Pollution degree 2, IEC 60529(IP54)
ment is carried out with low test current (15mA). The current will not Dimensions 185(L) × 167(W) × 89(D)mm
cause tripping out involved RCD even the one with the lowest nominal Weight 960g approx.
differential current (30mA). Accessories Molded plug test leads
• Model 4120A has the automatic RCD(ELCB)lock device. There is no 7121A(Distribution board test leads)
need to by-pass most passive RCD’s at distribution boards when con- 9147(Cord case)
ducting LOOP or PSC tests. 9121(Shoulder strap) Instruction manual
• Direct reading of Prospective Short Circuit Current (PSC)and earth
fault current.
• Safe voltage measurement function.
• Large custom digital display readout on all models.
• Measures low loop resistances(resolution of 0.01W)
• Automatic lock-out if test resister overheats.
• Large custom digital display readout .
• Visual indication of reversed phase and neutral wiring at socket.
• Designed to IP54 Rating
MODEL

• Complies with IEC61557


4120A

Loop Testing Methods


In the buildings mainly used for private residence where low volt-
age power is supplied from electric utilities the fundamental protec-
tion against electric shock hazards is provided by appropriately
coordinating the function of an earthing circuit with automatic
switches placed at the latter stage of indoor wiring circuits. This is
intended to quickly cut off the supply to an earthing circuit where a
fault occurs following touch voltage exceeding an acceptable limit.
Proper protection against electric shock hazards is given when the
TT wiring system satisfies the requirement as expressed by the fol-
lowing formula:
Ra × la ≤ 50
where Ra is the sum of the resistances of earth bars and protective
conductors and Ia is the maximum current of a protection system
provided for installations, indicating that the value obtained by mul-
tiplying Ra with Ia is not more than 50V. This means a maximum
voltage one can touch shall not exceed 50V in the event of an
earth fault.

■Method of earth fault loop impedance testing at socket outlet.


As shown in Fig.1, total earth fault loop impedance can be mea-
sured by plugging a loop tester into socket . The value of earth
fault loop impedance measured represents the sum of transform-
er coil winding resistance, phase conductor (L3) resistance and
protective conductor (PE) resistance as well as source earth re-
sistance and installation earth resistance. With the loop tester set Fig.1 Earth fault loop impedance testing at socket outlet.
to any one of the PSC (prospective short circuit current) range, it
is also possible to measure earth fault current.

42
KEW RCD TESTERS
Model 5406A series is an instrument to check RCD(ELCB) testers.
RCD trip time can be easily measured at the power outlet. Model
Selection Guide
MODEL 5402D MODEL 5406A
5406A has a microprocessor controlled constant current circuit that
Tripping time resolution 1ms
operates independent of voltage. This always allows highly accurate
0° / 180° Phase angle switch
measurement results. Constant current testing
Checks operation of DC sensitive breakers

5402D
MODEL 5402D

Rated tripping current 5/10/30/100/300/500mA


MODEL Fault condition settings × 1/2 × 1 Fast (250mA)
Trip current duration 2000ms 40ms (Fast trip)
Lowest resolution 1ms
Trip time accuracy ±2%rdg±3dgt
Operating voltage 220/230/240V [50Hz/60Hz]
Withstand voltage 2200V AC for 1 minute
Dimensions 140(L) × 90(W) × 20(D)mm
Weight 350g approx.
Accessories 7019(Test leads)
9045(Carrying case)
Instruction manual

• Accurate digital readout of tripping time.


• Two neon lamps give quick check for correct wiring.
• Compact, lightweight and simple to operate.
• Zero cross circuitry permits testing at 0 and 180 degree portion of
sine wave. At these two tests minimum (best) and maximum (worst) trip
times will be displayed.

5406A
MODEL 5406A

Rated tripping current 10/20/30/200/300/500mA


MODEL Fault condition settings × 1/2 × 1 × 5 × DC
Auto Ramp
Trip current duration 1000ms 200ms(× 5)
Lowest resolution 1ms
Trip time accuracy ±0.6%rdg±4dgt

5406A
Operating voltage 230V+10%-15%
(195V~253V)[50Hz]
Applicable standards IEC 61557-1,6
IEC 61010-1 CAT.3 300V
IEC 61010-031 Pollution degree 2

MODEL
IEC 60529(IP54)
Withstand voltage 3700V AC for 1 minute
Dimensions 186(L) × 167(W) × 89(D)mm
Weight 800g approx.
Accessories Molded plug test leads
9147(Cord case)
9121(Shoulder strap)
Instruction manual
Optional 7121A(Distribution board test leads)
5402D
• Custom microprocessor controlled for highest accuracy and reliability. • Constant current source circuitry ensures that a fluctuating mains
• 3 LEDs for checking correct wiring status. voltage does not affect the accuracy of readings.
• 0 and 180 degree phase angle switch permits quick tests and consistent • Large custom digital display readout .
readings. • Visual indication of reversed phase and neutral wiring at socket.
MODEL

• Digital read-out of tripping time. • Designed to IP54 Rating.


•Test of a large kind of RCD’s : • Complies with IEC61557
Standard, Selctive, AC and A(DC sensitive breakers).

Accessories

Molded plug test leads


MODEL 7123 (AU)Australian plug

MODEL 7124 (UK)British plug(13A)


MODEL 7121A
MODEL 7125 (EU)European SHUKO plug
(Distribution board test leads)
4118A, 4120A MODEL 7126 (SA)South african plug

43
KEW RCD TESTERS
KEW 5410
a[mKJGF

-EASUREMENTOF2#$TRIPTIME・-EASUREMENTOFTRIPOUTCURRENT
2ANGE ¾ ¾ ¾ !UTO2AMP (M!)
2ATEDVOLTAGE 6Ò
6  
6Ò
((Z)
4ESTCURRENT M! M! M!
-EASURINGRANGE 4ESTINGTIME 4ESTINGTIME 4ESTINGTIME ^OF)ΔN(GOESUPBY)
MS MS MS 4ESTINGTIME
MSXSTEPS
!CCURACY 4RIPTIME Ò%RDGÒDGT Ò%RDGÒDGT Ò%RDGÒDGT 4ESTCURRENTATEACHSTEP
4ESTCURRENT %^ %DGT %^ %DGT %^ %DGT %^ %
6OLTAGEMEASUREMENT
-EASURINGRANGE 6∼6((Z)
!CCURACY Ò%RDGÒDGT
!PPLICABLESTANDARDS )%# 0OLLUTIONDEGREE#!46#!46
)%# 
• Measurement of RCD trip time )%#  
Conducting testing of rated residual non-operating currents )%#()0)
at x 1/2 Range, measuring RCD trip time at x1 and x5 $ISPLAY COUNTS(DIGITS) ,ARGE,#$
Ranges. /PERATINGTEMPERATURE Ž#^Ž# RELATIVEHUMIDITY (NOCONDENSATION)
•Measurement of trip out current HUMIDITY
Measuring trip out current by varying current automatically. 3TORAGETEMPERATURE Ž#^Ž# RELATIVEHUMIDITY (NOCONDENSATION)
•Remote Test HUMIDITY
Enabling a user to hold the Test Leads with his both hands 7ITHSTANDVOLTAGE !#6MIN (BETWEENELECTRICALCIRCUITANDENCLOSURE)
by locking the Test Button. )NSULATIONRESISTANCE -7ORMORE6(BETWEENELECTRICALCIRCUITANDENCLOSURE)
Measurement will automatically start when the main voltage 3LEEPFUNCTION ()!UTOMATICALLYENTERS3LEEPMODEINMINAFTER
is detected (CURRENTCONSUMPTIONU!)
THELASTSWITCHOPERATION
•Voltage Measurement 4HISFUNCTIONDOESNTWORKATVOLTAGEMEASUREMENTS
Carrying out a constant measurement of voltage in the 4OEXITFROMTHE3LEEPMODE SETTHE&UNCTION
stand-by mode at each Range. SWITCHTO/&&POSITIONONCE ANDRE SETITTOTHE
•Auto-detection of Contact voltage 2ANGEATWHICHAMEASUREMENTTOBECONDUCTED
Detecting the voltage to earth of Earth electrodes or Protec- ()"ACKLIGHTTURNSOFFINMINAFTERITLIGHTSUP
tive conductors during RCD test - when applying test currents 0OWERSOURCE $#63IZE!!BATTERY20(35- )¾PCS
- at measurement using EARTH in order to prevent electrical $IMENSION (,)¾(7)¾($)MM
shocks caused by the damaged earth. Measurement will be 7EIGHT !PPROXG(INCLUDINGBATTERIES)
ceased at AC50V or more. 0OSSIBLENUMBER TIMESORMORE
(MEASUREEVERYSECATX2ANGE )ΔNM!)
KEW

•Dust- and Water-proof OFMEASUREMENTS


Dust- and Water-proof construction. (designed to IEC60529 !CCESSORIES (4ESTLEADS) (4ESTLEADWITHALLIGATORCLIP)
5410

IP54) (%XTENSIONPROD)s
•Backlight #ORDCASE 3HOULDERSTRAP
Facilitating working at dimly illuminated locations. )NSTRUCTIONMANUAL 20(35- ) (!!)¾

Accessories

MODEL 7128 MODEL 7129 MODEL 8017


Test leads Test lead with alligator clip Extension prod

Neutral - Line Line - Line Earth - Line


Connect the “PRIMARY” of the Connector Connect the “PRIMARY” of the Connector Connect the “PRIMARY” of the Connector
Block to the Neutral of the power of RCD, Block to L2 of the power of RCD, and the Block to Earth, and the “SECONDARY” of
and the “SECONDARY” of the Connector “SECONDARY” of the Connector Block the Connector Block to Line of the load of
Block to the Line of the load of RCD. to L1 of the load of RCD. RCD.
L1 L1
400V 400V 400V 400V
L2 L2
400V 230V 400V 230V
L3 L3
230V 230V 230V 230V
N N
Connection using Earth
Test lead with
alligator clip POWER

RED

POWER POWER
RED BLACK L2 L1
RED BLACK
NEUTRAL LINE

LOAD

LOAD
LOAD

44
KEW LOGGERS
MODEL 5000/5001 LEAK LOGGER

The leakage current is recorded by 3ch input


60,000 data is recorded
60,000 data is recorded when 1ch is used and when three all channels are used, RMS
20,000 data is recorded for each channel

Continuous measurement time


•Standard type : About 25 days (Model 5000) •Long life type : About 40 days (Model 5001)

Data where it doesn’t disappear even if battery is consumed


Data doesn’t disappear by using the nonvolatile memory when the battery is
consumed and the battery is exchanged. (warranty for 10 years)
It can be attached
Battery residual display to the metallic plate
The battery state is displayed by 4 stages. (When blinking is displayed, with magnet
it is possible to measure for about one day)

The present time, recording intervals, the


start of recording, the recording method, the
name of monitoring site and the comment
can be set by using supplied software
Selection of one time mode and
endless mode
•One time on
Stop recording when the memory is filled.
•One time off (endless)
Overwrite from old data and leave the
latest data.

Recall function
•The latest 10 data can be checked.
•The recall data is Direct data
Display month and date transmission to PC

5000/5001
Display hour and minute
Display current value by USB connection

LED BLINKS
when the current
setting value
is exceeded

MODEL
As for the leakage clamp sensor,
an arbitrary combination is possible

The leakage current clamp sensor can be


connected up to three channels

4 recording modes are available for insulation monitoring


1 Continuous recording mode 2 Event recording mode

interval •To record the current change of a long •Frequency is confirmed at a momentary
of
measurement term, and to measure and record at current value of the leak occurrence and time.
constant intervals, the state of leak that •The operation of ELCB is obtained by sam-
changes along with time is confirmed. pling for 1.6 milliseconds.
interval
• The memory number is 60,000. ( 1ch 8datas • W h e n t h e c u r re n t s e t t i n g v a l u e i s
(about 0.8 sec)
of only is used. ) exceeded, eight data (a true effective value
recording
•There are 15 kinds of settings at recording of about 0.8 seconds) and peak values are
intervals from 1 second to 60 minutes. recorded before and behind that.
• LED blinks when the current setting
value is exceeded.

3 The maximum value recording mode 4 Capture recording mode

recording •Easy finding of intermittent leak. •The observation of the shape of waves is
value
preset •The operation of ELCB is obtained by simply possible by sampling one millisec-
value
sampling for 1.6 milliseconds. ond.
preset •When exceeding set current value, it •When the current setting value is exceeded,
value
50% records the max. value every 10 seconds. the instantaneous value of 200 milliseconds
10 second The leak occurrence period of intermittent ( For 10 to 12 shape of waves ) is recorded
interval
leak can be checked when the set current before and behind that.
start recoding stop recording value becomes 50% or less, or 10 minutes •LED blinks when the current setting value
will be recorded. is exceeded.
•LED blinks when the current setting
value is exceeded.
45
KEW LOGGERS
Recorded data can be directly transferred to Software is
PC via USB cable Enhanced !
The user friendly PC software “KEW LOG Soft 2” is supplied.

System requirements Easy to set up with a PC Large data can be easily processed
PC with CPU: Pentium2 500MHz or higher and with operating system of
Windows®2000/XP/Vista
Memory: 64Mbyte or more
Display: Resolution 800 x 600 dots, 65536 colors or more
Hard-disk: Space required 100Mbyte or more
Others: With CD-ROM drive and USB drive
* Windows® is a registered trademark of Microsoft in the United States.
* Pentium is registered trademark of Intel in the United States.

● The type of the sensor connected to the logger will be automati-


cally recognized. A graph can be made by just one click Capable of registering the names of 1,000 sites

● Just click appropriate dialog boxes for set up if it is not required to


input any comments.

● By using commercially available USB hub, multiple loggers can be


connected to a PC and can set the synchronized time.

Measurements and precision(AC 50/60Hz)


•Continuous recording mode
Range Measurement range Accuracy Accuracy of sensor combination
100mA 0 to 100.0mA ±2.0%rdg±10dgt
±1.0%rdg±5dgt
1000mA 0 to 1000mA ±2.0%rdg±6dgt
•Event recording mode / The maximum value recording mode
Range Measurement range Accuracy Accuracy of sensor combination
100mA 0 to 100.0mA ±2.5%rdg±12dgt
±1.5%rdg±7dgt
1000mA 0 to 1000mA ±2.5%rdg±8dgt
•Capture recording mode*Accuracy of electric current adjudication is different. For details, refer to the operation manual
Range Measurement range Accuracy Accuracy of sensor combination
100mA 0 to 100.0mA ±4.0%rdg±2.5%fs
±3.0%rdg±2%fs
1000mA 0 to 1000mA ±4.0%rdg±2%fs
MODEL

MODEL 5000 MODEL 5001

Operation system Successive approximation


5000/5001

Input AC voltage(AC 100mV/A)


Maximum circuit voltage AC 170mVrms, 250mV peak value
Number of input channel 3 Channels
Measurement method True RMS
Measurement interval 1,2,5,10,15,20,30 sec. / 1,2,5,10,15,20,30,60 min.
Over range indication "OL" mark appears when exceeding measuring range
Warning of voltage of battery Battery mark display of 4 stages
Continuous available time battery life About 25 days on the event record mode ( Normal temp. ) About 40 days on the event record mode (Normal temp.)
Insulation resistance 50MΩ or more / 1000V
Dimensions 111(L) × 60(W) × 36(D)mm 111(L) × 60(W) × 42(D)mm
Weight About 255g (Include batteries) About 315g (Include batteries)
The maximum display 1049 counts
Applicable standards IEC 61010-1 CAT.3 300V Pollution degree2 IEC 61326 (EMC)
Power source Alkaline battery LR6 × 4 Alkaline battery LR6 × 6
Accessories Manual, Alkaline battery LR6, KEW LOG Soft 2 (PC software), 7148(USB cable), 9118(Carrying case[Soft])
Optional 8141/8142/8143(Leakage current clamp sensor) 9119(Carrying case[Hard]) 7185(Extension cable) 9135(Carrying case) 

Optional
Leakage current type

MODEL 8141 MODEL 8142 MODEL 8143


Clamp sensor Clamp sensor Clamp sensor The available combinations
φ24mm AC1000mA φ40mm AC1000mA φ68mm AC1000mA Set model MODEL 5000-01 MODEL 5000-02

Leak logger(Standard type) MODEL 5000×1 MODEL 5000×1


MODEL 8141(φ24mm)×1
Leakage clamp sensor MODEL 8142(φ40mm)×1 MODEL 8142(φ40mm)×2
MODEL 8143(φ68mm)×1 MODEL 8143(φ68mm)×1
Set model MODEL 5001-01 MODEL 5001-02

Leak logger(Long life type) MODEL 5001×1 MODEL 5001×1

MODEL 9119 MODEL 9135 Leakage clamp sensor


MODEL 8141(φ24mm)×1
MODEL 8142(φ40mm)×1 MODEL 8142(φ40mm)×2
Carrying case[Hard] Carrying case
MODEL 8143(φ68mm)×1 MODEL 8143(φ68mm)×1
46
KEW LOGGERS
KEW 5010/5020
3 channel inputs for the simultaneous recording of RMS
Leakage Current, Load Current and Voltage
Large capacity for storing 60,000 data points
60,000 data points can be recorded when 1ch is used, and when all the three channels are used,
20,000 data points per channel can be recorded.

Power Quality analysis. (only on KEW 5020)


(Power Quality: Reference voltage, Swell, Dip, Short power Interruptions) The logger can be fixed to a
metal distribution board via
the magnet on it’s rear side
Lowpass Filter will filter out the harmonics.
(Cutoff Frequency = Approx. 160Hz)

The logger can take external DC


input via an AC/DC adaptor (Model
8320), ideal for long recording times.

LED flickers when the preset current / voltage


value is exceeded.
(Available for Trigger / Capture Recording, Power Quality
Analysis modes)

LED flickers
when the preset
current/voltage
is exceeded

CALL : Confirmation of recorded data

5010/5020
• The following can be displayed: number of
recorded data points, (max+ min+ peak) value for
each channel complete with time/date information
in the Normal recording mode. (Detected values
(i.e. when values are outside preset limits) can be
displayed in other recording modes)
• RECALL: The last 10 recorded data points
including time/date can be recalled on the
logger display.

KEW
Selection of One-time mode
or Endless mode
One-time on :
Recording will stop when memory is used up.
One-time off :
Overwrite the old data, and store the latest data.

Non Volatile Memory


Recorded data will be retained even if the batteries are exhausted or replaced due to the presence of a Voltage sensor with a built-in-
nonvolatile memory (guaranteed for 10 years) differential amplifier (KEW 8309:
option) can measure the floating
Battery power indicator voltage (=phase to phase voltage
Indicates battery voltage in 4-levels. ungrounded)
(It is possible to use the logger for a further approx 24 hours even after the warning symbol is flashing.)

Supplied with the user friendly software“ KEW LOG Soft 2”.
This permits editing, analysis and graphical display of data.
The recorded data is downloadable onto
a PC via USB cable.
Variation of the measured voltage and current data can be
confirmed simultaneously on the PC display monitor.
(only on KEW 5020)
Simplified Power Integration Various clamp sen-
(The “KEW LOG Soft 2” uses current and voltage recorded to sors are available
calculate the integral power consumption)

Continuous measuring time :


The clamp sensor and / or voltage sensors
Approx. 10 days (Alkaline Battery) can be connected to any of the 3 channels
* The logger unit automatically identifies the sensors connected. 47
KEW LOGGERS
4 recording modes make various measurements possible
Normal recording mode Trigger recording mode
For monitoring power line status or an intermit- For observing an irregular operation of an
tent leakage. ELCB/RCD, an irregular current / voltage.
● Records the variation of the ● Detects the value, time and
current / voltage in a given frequency of the current /
interval (For monitoring the voltage when the preset
variation of the current / value is exceeded. nÊ`>Ì>­vœÀÊ>««ÀœÝ°Êä°nÃiV®
voltage against time.)
● When the detection level (i.e.
● A choice of 15 recording preset value) is exceeded, 8
intervals are available: 1 sec. to 60 min. data points (True RMS values
(1,2,5,10,15,20,30 sec, 1,2,5,10,15,20,30,60 min.) for approx. 0.8 sec) and peak value are recorded before and after the
preset value is exceeded.
● The average of the measured value in every recording interval is
recorded. The Max., Min. and Peak values (sampled crest value ● Inrush current or an abnormal current / voltage can be detected by
converted to sine RMS value) are recorded every 10 readings. sampling the inputs at every 1.6ms.
● LED flickers when the measured values exceed the preset current /
voltage value.

Capture recording mode Power Quality Analysis Mode


For observing waveforms easily. For monitoring and observing voltage fluctua-
tions.
● Waveform display via a ● Detects the reference volt- -Ì>ÀÌ ˜`

PC by sampling the inputs age, Swell, Dip and Short -ÞÃÌi“


every 0.55ms. Interruption. Records the *œÜiÀ -Üi

values detected with the ˆ«


● When the preset current / start time and end time. -…œÀÌ
voltage value is exceeded, ˜ÌiÀÀի̈œ˜

instantaneous values are ● Samples the inputs every


recorded for 200ms (from 0.55ms and detects the volt-
10(50Hz) to 12 (60Hz) waveforms) before and after preset value age fluctuation every 10ms.
is exceeded.
● LED flickers when the voltage fluctuation is detected.
● LED flickers when the measured values exceed the preset current /
voltage value.

œÀ“>Ê,iVœÀ`ˆ˜}Êœ`iÊ­
ÊxäÉÈäâ]Ê-ˆ˜iÊÜ>Ûi]ʘ«ÕÌ\Ê£ä¯ÊœÀʓœÀiʜvÊ̅iÊÀ>˜}iÊ>ÌÊ
£®
KEW

2ANGE 2-3!CCURACY
M! ÒRDGÒFS !CCURACYOFSENSOR
5010/5020

/THERRANGES ÒRDGÒFS !CCURACYOFSENSOR


#RESTFACTOR ORLESS2-3ACCURACYSINE RDG FS
I>Ý]ʈ˜Ê>˜`ʘÃÌ>˜ÌÊ*i>ŽÊÛ>ÕiÃʈ˜Ê œÀ“>Ê,iVœÀ`ˆ˜}ʓœ`iÊ>ÀiʍÕÃÌÊÀiviÀi˜ViÊÛ>ÕiÃÆÊ̅iˆÀÊ>VVÕÀ>VˆiÃÊ>Ài˜¿ÌÊ}Õ>À>˜Ìii`°

/Àˆ}}iÀÊ,iVœÀ`ˆ˜}Êœ`iÊ­
ÊxäÉÈäâÊȘiÊÜ>Ûi®
2ANGE !CCURACY
M! ÒRDGÒFS !CCURACYOFSENSOR
/THERRANGES ÒRDGÒFS !CCURACYOFSENSOR


>«ÌÕÀiÉÊ*œÜiÀÊ+Õ>ˆÌÞʘ>ÞÈÃÊ,iVœÀ`ˆ˜}Êœ`i
2ANGE !CCURACY
M! ÒRDGÒFS !CCURACYOFSENSOR
/THERRANGES ÒRDGÒFS !CCURACYOFSENSOR

a[mKFGF a[mKFHF
2ECORDINGMODE .ORMAL 4RIGGER #APTURE .ORMAL 4RIGGER #APTURE 0OWERQUALITYANALYSIS
/PERATINGSYSTEM 3UCCESSIVEAPPROXIMATION#(SINGLESYNCHRONIZEDSAMPLING
2ATEDMAXWORKINGVOLTAGE !#6RMS 6PEAKVALUE
.UMBEROFINPUTCHANNEL CH
-EASURINGMETHOD 4RUE2-3
2-3MEASURINGINTERVAL APPROXMS
3AMPLINGINTERVAL.ORMAL4RIGGERMODE APPROXMS#(
#APTUREMODE APPROXMSWAVEFORMATEVERYMS
01!MODE ˆ APPROXMS
,OWBATTERYWARNING "ATTERYMARKDISPLAYINLEVELS
/VER RANGEINDICATION /,MARKISDISPLAYEDWHENEXCEEDINGTHEMEASURINGRANGE
!UTOPOWEROFF 0OWER OFFFUNCTIONOPERATESAUTOMATICALLYAFTERASWITCHREMAINSFORMINWHENRECORDINGISSTOPPED
,OCATIONFORUSE )NDOORUSE !LTITUDEUPTOM
/PERATINGTEMPERATUREHUMIDITYRANGE —#^—#2ELATIVEHUMIDITYORLESSNOCONDENSATION
"ATTERY $#6!LKALINEBATTERY,2 sPCS%XTERNALSUPPLY$#63PECIAL!#!DAPTOR
0OSSIBLEMEASUREMENTTIME !PPROXDAYSWITHALKALINE,2BATTERIES
!PPLICABLESTANDARDS )%# #!460OLLUTIONDEGREE)%#%-#
7ITHSTANDVOLTAGE !#62-3(Z FORSEC
$IMENSIONS , s7 s$ MM
7EIGHT !PPROXG
!CCESSORIES !LKALINEBATTERY,2¾PCS#ARRYINGCASE;3OFT= +%7,/'3OFT0#SOFTWARE 53"CABLE
)NSTRUCTIONMANUAL1UICKMANUAL)NSTALLMANUAL53".OTICESHEET
/PTIONAL ,EAKAGE,OADCURRENTCLAMPSENSOR ,OADCURRENTCLAMPSENSOR &LEXIBLECHAMPSENSOR
6OLTAGESENSORONLY+%7 !#ADAPTOR #ARRYINGCASE #ARRYINGCASE;(ARD= %XTENSIONCABLE)
3MALLCLIPADAPTOR)
48
KEW LOGGERS
Analyzing and processing the recorded data with a PC
The user friendly PC software “KEW LOG Soft 2” is supplied.
Software is
System requirements Enhanced !
PC with CPU: Pentium2 500MHz or higher and Hard-disk: Space required 100Mbyte or more
with operating system of Windows® Others: With CD-ROM drive and USB drive
2000/XP/Vista
* Windows ® is a registered trademark of Microsoft in the
Memory: 64Mbyte or more United States.
Display: Resolution 800 x 600 dots, 65536 * Pentium is registered trademark of Intel in the United
colors or more States.

Easy to set up with a PC Large data can be easily processed ● The type of the sensor connected to the
logger will be automatically recognized.

● Just click appropriate dialog boxes for set up


if it is not required to input any comments.

● By using commercially available USB hub,


multiple loggers can be connected to a PC
and can set the synchronized time.

(Normal and Trigger recording modes can be set up through


the logger itself.)

A graph can be made by just one click Display of Power Quality Capable of registering the names of 1,000 sites

5010/5020
Optional
Load current type Leakage & Load current type

KEW
KEW 8146 KEW 8147 KEW 8148
KEW 8121 KEW 8122 KEW 8123 Clamp sensor
φ24mm AC30A
Clamp sensor
φ40mm AC70A
Clamp sensor
φ68mm AC100A
Clamp sensor Clamp sensor Clamp sensor
φ24mm AC100A φ40mm AC500A φ55mm AC1000A
Leakage current type
KEW 8129*
Flexible clamp sensor
Max φ150mm AC3000A
8129-01 (for 1ch)
8129-02 (for 2ch)
8129-03 (for 3ch) MODEL 8141 MODEL 8142 MODEL 8143
Clamp sensor Clamp sensor Clamp sensor
* Can use with after the following serial numbers. 5010:No.8029792~ 5020:No.8031560~ φ24mm AC1000mA φ40mm AC1000mA φ68mm AC1000mA

KEW 8309 MODEL 7197 MODEL 8320 MODEL 9119 MODEL 9135
Voltage sensor Small clip adaptor AC adaptor Carrying case[Hard] Carrying case
49
KEW MULTI FUNCTION TESTERS
Model 6010A is an advanced multifunction tester that can per-
MODEL 6010A form all the testing required by IEC 364-6-61 with a single instru-
ment. It can be used to test insulation resistance, continuity, loop
impedance and RCDs(ELCBs), four major test requirement in the
electrical testing industry. This four-in-one instrument eliminates the
need to carry individual single function testers. Model 6010A is
designed to IEC 61010-1 and available with CE marking for EMC
compliance.
MODEL 6010A

Continuity testing
Measuring ranges 0~19.99 and 10.0~199.9Ω (2 auto ranges)
Open circuit voltage > 4V(as per IEC 364)
Short circuit current > 200mA DC(as per IEC 364)
Accuracy ±(3% + 3dgt)
Loop impedance testing
Rated voltage 230V AC +10%, -15% [50Hz]
Voltage measuring 100~250V AC [50Hz]
range
Impedance ranges 20/2000Ω
nominal test current 25A (20Ω range) 15mA (2000Ω range)
Test period 1/2 cycle (10ms)
Accuracy 20Ω range : ±(3% + 8dgt) 2000Ω range : ±(3% + 8dgt)
Insulation testing
Measuring ranges 0~19.99 and 10.0~199.9MΩ (2 auto ranges)
Test voltage 500V DC
Output voltage on 570V DC±6%
open circuit
Rated current >1mA(as per IEC 364)
Accuracy ±(3% + 3dgt)
RCD testing
Rated voltage 230V AC +10%, -15% [50Hz]
Trip current RCD × 1/2: 5, 15, 50, 150, 250mA
Continuity and Insulation Testing settings RCD × 1: 10, 30, 100, 300, 500mA
• Live circuit warning LED: Trip current duration RCD × 1/2 × 1: 2000ms
Immediate illumination of a warning lamp if the circuit under test is live. Fast trip 150mA
• Auto Discharge: Accuracy Trip current ±3% of test current at 230V.
Allows fast and safe discharge of electrical energy stored in capacitive Trip time ±(3% + 3dgt)
circuits following testing. General
• Integral overload protection on internal continuity and insulation test cir- Applicable standards IEC 61010-1 CAT.3 300V Pollution degree 2
MODEL

cuitry. IEC 61010-031 IEC 61557


• Autoranging. Withstand voltage 4000V AC for 1 minute
• 500V DC test voltage for insulation tests. Power source R6P(AA)(1.5V) × 8
6010A

• 200mA short circuit current on continuity ranges. Dimensions 175(L) × 115(W) × 86(D)mm
Weight 780g approx.
Loop and RCD Testing Accessories 7025(Test leads) KAMP10 (Test lead with IEC connector)
• Wiring connection check LED’s: 9092(Cord case) 9148(Shoulder strap) Shoulder pad
Immediate indication if wiring of circuit under test is correct. R6P(AA) × 8 Instruction manual
• Overheat Protection: Optional 7133A(Distribution board test leads)
Rapid detection of overheating of internal circuitry,display of warning sig- KAMP10(EU): European SHUKO plug KAMP10(UK): British plug(13A)
nal to user and automatic halting of measurement. KAMP10(AU): Australian plug KAMP10(SA): South african plug
• Supply Voltage Indication:
Can display supply voltage value in loop impedance mode.
• Low Current Loop Impedance Test:
Short duration low test current will prevent tripping of many passive RCDs.
• Auto Data Hold:
Retains displayed reading for set period following test.
•Phase Angle Selection:
Selection of test current from +ve or -ve half cycle of waveform can pre-
vent tripping of polarized type RCDs.

Accessories
Continuity and insulation testing LOOP and RCD testing

MODEL 7025 Test leads KAMP10 Test lead with IEC connector

50
KEW MULTI FUNCTION TESTERS
6010B
a[mLFGFX

#ONTINUITYTESTING
KEW -EASURINGRANGE 7!UTO RANGING
/PENCIRCUITVOLTAGE 6
3HORTCIRCUITCURRENT M!
!CCURACY ÒRDG DGT
)NSULATIONRESISTANCETESTING
-EASURINGRANGE -7!UTO RANGING
4ESTVOLTAGE 6
/PENCIRCUITVOLTAGE  
2ATEDCURRENT M!
!CCURACY ÒRDG DGT
,//0)MPEDANCETESTING
)MPEDANCERANGE 77
2ATEDVOLTAGE 6  ;(Z=
.ORMALTESTCURRENT 7!MS
7M!MSMAX
!CCURACY ÒRDG DGT
2#$TESTING
4ESTCURRENT ¾ ¾     M!MS
4ESTCURRENT &!34 M!MS
DURATION $#    M!MS M!MS
!UTORAMP 'OESUPBYFROMTOOF)$NMSs
2ATEDVOLTAGE 6  (Z
!CCURACY 4ESTCURRENT s  s &AST  
$#Ò!UTORAMPÒ
4RIPTIME ÒRDG DGT
5CTESTING
-EASURINGRANGE 6
2ATEDVOLTAGE 6  ;(Z=
4ESTCURRENT M!AT)$NM!
M!AT)$NM!
• Continuity M!AT)$NM!
20/200Ω 200mA Test Current !CCURACY  RDGÒDGT
• Insulation 'ENERAL
500/1000V, 20/200MΩ 1mA Rated Test Current !PPLICABLESTANDARDS )%# #!460OLLUTIONDEGREE
• Loop Impedance )%#       )%#)0
20/2000Ω 15mA Test Current at 2000Ω (No RCD Trip) 0OWERSOURCE 2OR,2s
• RCD $IMENSIONS , s7 s$ MM
10/30/100/300/500mA, ×1/2, ×1, Fast Trip (40ms), DC, Auto Ramp 7EIGHT GAPPROX
•Test of a large kind of RCD’s : !CCESSORIES 4ESTLEADS +!-04ESTLEADWITH)%#CONNECTOR
Standard, Selctive, AC and A(DC sensitive breakers). #ORDCASE 3HOULDERSTRAP 3HOULDERPAD

6010B
• Uc (Contact Voltage) 100V )NSTRUCTIONMANUAL
• Designed to IEC 61010-1, IEC 61557 /PTIONALS !$ISTRIBUTIONBOARDTESTLEADS
• Data Memory : 300 measured results  23#23#ADAPTORWITH¸+%72EPORT3OFTWARE ¸
• Download Results to PC by Using 8212 Data Communication Adaptor  53"53"ADAPTORWITH¸+%72EPORT3OFTWARE ¸
through Optical RS-232C Port.

KEW
Optional Accessories
MODEL 8212-USB MODEL 8212-RS232C MODEL 7133A Test leads
USB adaptor with “KEW Report (Software)” RS232C adaptor with “KEW Report (Software)”

Specifications
MODEL 8212-USB MODEL 8212-RS232C "KEW Report" Software for report
Communication method USB Ver1.1 - “KEW Report” transfers measurement data from
Driver type Virtual COM port - the KEW6010B to a PC via MODEL8212-USB or
MODEL8212-RS232C.
Communication speed 19200bps max. 9600bps max.
Dimensions Adaptor : 53(L)×36(W)×19(D)mm Adaptor : 61(L)×36(W)×19(D)mm
Cable : 2m approx. Cable : 1.6m approx.
Operating temperature and humidity -10~+50°C 85%RH or less with no condensation 0~+40°C 85%RH or less with no condensation
Storage temperature and humidity -20~+60°C 85%RH or less with no condensation

System Requirements
• PC/AT compatible machine on which • 20MB or more of free hard disk space recommended.
Microsoft Windows® 2000/XP/Vista can operate. • One free COM port or One free USB port. ❈ Trade mark
®
• Pentium 233MHz or more recommended. • CD-ROM drive (necessary at installing) Windows is a registered trade mark of Microsoft
• RAM 64Mbyte or more. in the United States.
Pentium is a registered trade mark of Intel in the
• XGA (1024×768) recommended.
United States.

51
KEW MULTI FUNCTION TESTERS
The Model 6011A can perform FIVE separate test functions: insu-
MODEL 6011A lation, continuity, earth loop impedance, prospective short circuit
current and RCD trip testing in full compliance with IEC61557.

MODEL 6011A

Continuity testing
Measuring ranges 20/200/2000Ω (Autoranging)
Open circuit voltage >6V
Short circuit current >200mA DC
Accuracy ±(1.5%rdg+3dgt)
Insulation testing
Measuring ranges 20/200MΩ (Autoranging)
Test voltage 250V 500V 1000V DC
Output voltage on 250V+40%, -0%
open circuit 500V+30%, -0% 1000V+20%, -0%
Rated current > 1mA
Accuracy ±(1.5%rdg+3dgt)
Loop impedance testing
Rated voltage 230V AC +10%, -15% [50Hz]
Voltage measuring 100~250V AC [50Hz ]
range
Impedance ranges 20/200/2000Ω
Nominal test vurrent 25A (20Ω range) 15mA (200Ω range) 15mA (2000Ω range)
Accuracy 20Ω range ±(3%rdg +4dgt) 200Ω range ±(3%rdg +8dgt)
2000Ω range ±(3%rdg +4dgt)
PSC testing
Rated voltage 230V AC +10%, -15% [50Hz]
PSC ranges 200A(15mA Test current) 2000A(25A Test current)
20kA(25A Test current)
Accuracy PSC accuracy derived from measured loop
impedance specification and measured voltage specification
RCD testing
Rated voltage 230V AC +10%, -15% [50Hz]
Trip current settings RCD × 1/2 : 10,30,100,300,500,1000mA
• Complies with IEC61557. RCD × 1 : 10,30,100,300,500,1000mA
• Designed to IP 54 Rating. RCD × 5 : 10,30,100,300mA (on × 5 range max current 1A)
• Live circuit and wiring connection check LED’s. Trip current duration RCD × 1/2 × 1: 2000ms RCD fast: 50ms
• Triple ranges insulation tests at 250, 500 and 1000V. Accuracy Trip current +10%-0% of test current at 230V
• Triple range loop and PSC tests 15mA test current at 200Ω/2000Ω Trip time ±(1%rdg + 3dgt)
range(No RCD Trip). General
MODEL

• Phase angle selection on RCD ranges. Applicable standards IEC 61010-1 CAT.3 300V pollution degree 2
• Polarity switch for continuity tests. IEC 61557 IEC 60529(IP54)
• Auto-null facility for continuity tests. Withstand voltage 3700V AC for 1 minute
6011A

• Earth probe for loop impedance testing on extraneous metalwork. Power source LR6 (1.5V) × 8
• Contact Voltage Reading. Dimensions 130(L) × 183(W) × 100(D)mm
•Test of a large kind of RCD’s : Weight 1100g approx.
Standard, Selctive, AC and A(DC sensitive breakers). Accessories KAMP10(Test lead with IEC connector)
7122A(Test leads)
7132A(KSLP5)(External earth probe)

Accessories 9092(Cord case) 9121(Shoulder strap)


Battery LR6 (1.5V) × 8 Instruction manual
Optional 7133A(Distribution board test leads)
KAMP10(EU):European SHUKO plug / KAMP10(UK):British plug(13A) /
KAMP10 (AU):Australian plug / KAMP10(SA):South african plug

Optional Accessory

MODEL 7132 (KSLP5) MODEL 7122A


External earth probe Test leads

AU UK

EU SA

Plug
KAMP 10 MODEL 7133A (OMA DIEC)
Test lead with IEC connector Distribution board test leads

52
KEW MULTI FUNCTION TESTERS
KEW 6016 KEW 6016 Multifunction tester
makes “Easy of Use” it’s top
priority with such features as:

Advanced Anti-Trip Technology (ATT) for avoiding


RCDs trip during loop testing.

Continuity Measurement
Continuous testing can be carried out by use of the test button lockdown
A single rotary dial to make your
feature. A selectable buzzer gives instantaneous indication of continuity. selection.
Null facility eliminates the test lead resistance from the results, the nulled
value is retained even if the instrument is switched off. Live circuit warn-
ings are given by a flashing LED, buzzer and indication on the display.

Insulation Measurement Slim remote probe with test button as well as a


Three selectable test voltages 250V, 500V and 1000V. An auto- lockdown option on the instrument for the most
discharge function ensures that circuits are not hazardous after testing. convenient hands free testing.
A red LED gives warning of high voltage output during testing and dis-
charging of the circuit. In case of connecting to a live circuit, a live circuit
warning is given by flashing LED, buzzer and indication on the display.

Loop Impedance Measurement


A patented (ATT) low current loop impedance test enables high accuracy loop measurements and quick testing without tripping RCD’s.
A high current alternative is selectable for even higher accuracy and instantaneous results. The subsequent test will default to the low current test, this saves any

6016
inadvertent tripping of the RCD. The KEW6016 allows also for phase to phase loop tests.

PSC / PFC Measurement


The Prospective Short Circuit Current (PSC) and Prospective Fault Current (PFC) are automatically calculated and shown on the display. As loop testing, the func-

KEW
tion has low and high test current options with the default to low current to avoid inadvertent tripping of RCDs.

RCD Measurement
The KEW 6016 has a comprehensive RCD test feature for RCD type AC (Alternative Currents), RCD type A (Pulsating Direct Currents), General and Selective (de-
layed).
Measures at 1⁄2 x, 1x, 5x of nominal RCD current. It also has Ramp Test and Auto test where all results are shown on one screen. Touch voltage limit can be se-
lected for 25V or 50V depending on application.

Earth Measurement
Using the classical Volt-Amper method with two auxiliary earth spikes and without external power source. All test leads and spikes are supplied as standard acces-
sories.

Phase rotation
KEW 6016 can check the phase rotation of three phase lines with clear indication of the sequence on the display.

Voltage Measurement
In addiction to the voltage measurement, this function gives also the Frequency of the voltage under test.

Hands Free Testing RCD (ELCB)-Auto Test

Auto test enables complete


The instrument testing of RCD (6 tests)
features a test button while the operator simply
in the probe and a stands by and resets the
lockdown test but- RCD. All the results are
ton for ‘hands free’ displayed on one screen –
operation. no need to scroll.

53
KEW MULTI FUNCTION TESTERS
KEW 6016

Continuity RCD
Range 20/200/2000W (Auto-ranging) X1/2: 2000ms
Open circuit voltage (DC) 5V±20%(*1) X1: G:550ms / S: 1000ms
Short circuit current Greater than 200mA Trip current Duration X5: 410ms
±0.1W (0~0.19W ) Goes up by 10% from 20% to 110%
Accuracy Ramp:
±2%rdg+8dgt (0.2~2000W) G:300ms/S:500msX10 times
Insulation resistance X1/2, X1, X5,
230V+10%-15% 50/60Hz
Range 20/200/2000MW (Auto-ranging) Ramp, Uc:
20/200MW 250V+25% -0% Depending on the accuracy at each function.
Open circuit voltage (DC)
20/200/2000MW 500V+25% -0%, 1000V+20% -0% Rated voltage Measurement sequence:
20/200MW 1mA or greater @ 250kW Auto: X1/2 0°→X1/2 180°→X1 0°→X1 180°→X5 0°→X5 180°
Rated current
20/200/2000MW 1mA or greater @ 500kW, @ 1MW Measurements with x5 are not carried out for RCDs
±2%rdg+6dgt (0~19.99MW) with nominal current of 100mA or more.
20/200MW
±5%rdg+6dgt (20~200MW) AC Type X1/2: -8%~-2%, X1, X5: +2%~+8%, Ramp: ±4%
Accuracy
±2%rdg+6dgt (0~199.9MW) Accuracy Trip current X1/2: -10%~0%, X1, X5: 0%~+10%, Ramp: ±10%
20/200/2000MW A Type
±5%rdg+6dgt (200~2000MW) Uc: +5%~+15%rdg±8dgt
Loop impedance Earth
Function L-PE, L-PE (ATT), L-N / L-L Range 20/200/2000W Auto-Ranging
L-PE, L-PE (ATT): 100~260V (50/60Hz) 20W: ±3%rdg+0.1dgt
Accuracy
Rated voltage L-N: 100~300V (50/60Hz) 200/2000W: ±3%rdg+3dgt (Auxiliary earth resistance 100±5%)
L-L: 300~500V (50/60Hz) Phase Rotation
20W: 6A/20ms Rated Voltage 50-500V 50/60Hz
Nominal test current at 200W: 2A/20ms Correct phase sequence: are displayed “1.2.3” and mark
Remarks
0W external loop: 2000W: 15mA/500ms Reversed phase sequence: are displayed “3.2.1” and mark
Magnitude/Duration(*2) L-N: 6A/60ms Volts
N-PE: 10mA/approx. 5s Function Volts Frequency
Range 20/200/2000W Auto-Ranging (L-N < 20W) Rated voltage 25~500V, 45~65Hz
L-PE, L-N / L-L: ±3%rdg+4dgt*3 ±3%rdg+8dgt*4 Measuring range 25~500V 45~65Hz
Accuracy
L-PE (ATT): ±3%rdg+6dgt*3 ±3%rdg+8dgt*4 Accuracy ±2%rdg+4dgt ±0.5%rdg+2dgt
PSC (L-N/L-L) / PFC (L-PE) General
Function PSC, PFC, PFC (ATT) IEC 61010-1 CAT.Ⅲ 300V(500V L to L) Pollution degree 2
PSC: 100~500V 50/60Hz Applicable standards IEC 61010-031, IEC 61557-1,2,3,4,5,6,7,10
Rated voltage
PFC, PFC (ATT): 100~260V 50/60Hz IEC 60529(IP40), IEC 61326(EMC)
Nominal test current at PSC: 6A/20ms Power source LR6 × 8
0W external loop: PFC: 6A/20ms, 2A/20ms, 15mA/500ms Dimensions 136(L) × 235(W) × 114(D)mm
Magnitude/Duration(*5) PFC (ATT): L-N: 6A/60ms, N-PE: 10mA/approx. 5s Weight 1350g (including batteries.)
Range 2000A/20kA Auto-Ranging 7218(Mains cord) 7196(Temote test lead)
PSC/PFC accuracy is derived from measured loop 7188(Distribution board fused test leads)
Accuracy
impedance specification and measured voltage pecification 7228(Earth cord) 8032(Auxiliary earth spikes)
Accessories
RCD 8212-USB(USB adaptor with KEW Report(Software))
Function X1/2, X1, X5, Ramp, Auto,Uc Cord case, 9142(Carrying Case), 9121(Shoulder strap), Buckle,
KEW

X1/2, X1,Uc: 10/30/100/300/500/1000mA Battery, Instruction manual


Trip current setting X5: 10/30/100mA Optional 8212-RS232C(RS232C adaptor with KEW Report(Software))
6016

Ramp: 10/30/100/300/500mA *1: Voltages are output when measurement resistance is under 2100 ohm.
*2: at 230V  *4: Other voltages except for *3
*3: 230V+10%-15% *5: at 230V

Accessories

MODEL 7188 MODEL 7196 MODEL 7218 MODEL 7228 MODEL 8032 MODEL 9142
Distribution board fuse test Test leads with remote control Power cord Earth cord Auxiliary earth spikes Carrying Case
lead set switch
Optional Accessories
"KEW Report" Software for report
“KEW Report” transfers measurement data from the KEW6010B
to a PC via MODEL8212-USB or MODEL8212-RS232C.

MODEL 8212-RS232C ❈ Trade mark


8212-USB
®
Windows is a registered trade mark of Microsoft in the United
MODEL RS232C adaptor with “KEW Report (Software)” States.
USB adaptor with “KEW Report (Software)” Pentium is a registered trade mark of Intel in the United States.

54
KEW MULTI FUNCTION TESTERS
MODEL 6017/6018
The Model 6017/6018 can perform THREE separate test func-
tions; insulation, earth resistance, voltage testing.

MODEL 6017/6018

Insulation testing
6017 Test voltage 125V/20MΩ
250V/50MΩ
500V/100MΩ
6018 Test voltage 250V/50MΩ
500V/100MΩ
1000V/2000MΩ
Accuracy ±5%rdg
Earth resistance
Simplified precision 12Ω/120Ω/1200Ω
measurement
Accuracy ±3% of full scale value
AC voltage
0~600V AC ±3% of full scale value
Earth voltage
0~60V AC ±3% of full scale value
General
Applicable standards IEC 61010-1 CAT.3 600V pollution degree 2
IEC 61010-031 IEC 61557
Withstand voltage 5550V AC for 1 minute
Power source LR6(1.5V) × 8
Dimensions 130(L) × 183(W) × 100(D)mm
Weight 1000g approx.
Accessories 7150(Remote control switch set)
9121(Shoulder strap)
Battery LR6 (1.5V) × 8
Instruction manual
Optional 7100(Precision measurement cord set)
8016(Pickel type prod)

• Designed to meet IEC61010-1 CAT.3 600V.


• Test leads with remote control switch.
(For insulation&Simplified Earth Test) Accessories
• Back light function.

6017/6018
• Color coded scales and range switch position for easy reading.
• Automatic warning when resistance of auxiliary earth spikes is in excess
of tolerance.
• Can be hung around the neck for both hands’ operation.

Optional Accessories

MODEL

MODEL 7150
MODEL 7100 MODEL 8016 Remote control switch set
Precision measurement cord set Pickel type prod
(7095, 8032, 8200-03, 9091)

MODEL 7095 MODEL 8032 MODEL 9091 MODEL 8200-03


Test leads for earth resistance Auxiliary earth spikes Carrying case for cord reels Cord reels[3 pcs]
55
KEW MULTI FUNCTION TESTERS
6020/6030
MODEL 6020 MODEL 6030 MODEL 6020/30

Insulation test specifications


MODEL Test voltage 125V/250V 250V/500V 1000V
Measuring ranges 0 ~1.999MΩ 0 ~19.99MΩ
(MΩ) 1.00 ~19.99MΩ 10.0 ~199.9MΩ
10.0 ~199.9MΩ 100 ~1999MΩ
(3 auto ranges)
Accuracy ±2%rdg±3dgt ±10%rdg(on 1000~2000MΩ)
Open circuit voltage +20% -0% of Rated Test Voltage
Rated test current 1mA DC +20%-0%
Short circuit current 1.3mA DC approx.
Effect of AC component Within ±10% of reading when 5µF capacitor
of terminal voltage is connected in parallel on insulation test
Overload protection 1200V (DC + ACp-p) for 10 seconds
Earth resistance test specifications
Measuring ranges(Ω) 0 ~199.9Ω 100 ~1999Ω (2 auto ranges)
Accuracy ±2%rdg±3dgt (at 500Ω auxiliary earth resistance)
Measuring method By constant current inverter 820Hz approx. 2mA approx.
Overload protection 200V AC for 10 seconds between measuring terminals
Voltage test specifications
Measuring ranges(V) 0~199.9 / 100~600V (2 auto ranges)
Accuracy ±1%rdg±4dgt
Sensing True RMS
Input impedance 2MΩ
Overload protection 900V AC for 1 minute
Phase check specifications
Measuring range 100~600V (50Hz/60Hz)
(for checking correct or reverse phase and open phase)
General
Display 3 1/2(1999)digit large LCD
Response time Approx. 4 seconds for AC voltage and earth resistance tests
Approx. 5 seconds for insulation resistance tests.
• Water resistant (IEC60529 IP57). Withstand voltage 5550V AC for one minute
• Test leads are stored in a cord reel module. Effect of drop No electrical and mechanical damage shall occur when the unit
• Easy-to-read large digital display. is dropped from a height of 1 m onto the concrete floor.
• The instrument automatically turns itself off in about 30 minutes to con- Effect of temperature Readings shall not differ greater than specified below when
serve battery life, if no push buttons are pressed. taken at a reference temperature of 23°C and varied temperature
• Illumination on test probes for work at night or in dimly lit locations. of 0°C and 40°C. AC voltage 3% ±2dgt insulation resistance
• Display back-light to improve legibility in poor lighting conditions. and earth resistance 5% ±2dgt
• Autoranging; three ranges for insulation resistance, two ranges for earth Operating temperature 0~40°C
resistance and two AC voltage ranges. Range
• The instrument and all accessories in one carrying case. Dimensions 130 × 238 × 207mm
• AC voltage range; (main body plus cord reel module)
• True RMS sensing permits accurate measurement of voltage with distor-
105 × 238 × 207mm (main body only)
tion and harmonics generated by equipment using SCRs or TRIACs. Weight Approx. 1.6kg (main body only)
• Insulation resistance range; Approx. 750g (cord reel module only)
MODEL

• Three test voltages; Model 6020 (125V, 250V, 1000V)


Power supply 1.5V LR6 alkaline battery or equivalent × 8 (for main body only)
• Three test voltages; Model 6030 (250V, 500V, 1000V)
1.5V LR6 alkaline battery or equivalent × 1 (probe only)
• 1mA test current at the minimum load.
Applicable sandards IEC 61010-1 CAT.3 600V Pollution degree 2
6020/6030

• Automatically releases electric charges stored in the circuit under test.


Accessories 7088(Test leads for Phase Indicator)
• Remaining charges can be observed on AC voltage range.
7089(Test leads [large]) 7090(Test leads [small])
• Remote control switch on a test probe.
7091(Test lead for earth resistance) × 1set (red-20m, yellow-10m, green-5m)
• Earth resistance range; 7092(Cord reel) 8082(Extension probe)
• Checks resistance of auxiliary earth bars.
8083(Auxiliary earth spikes) × 1set 9081(Carrying case)
• Can make both simplified and normal measurement.
LR6 x 9, Instruction manual,
•Phase test; 9149(Shoulder strap), Shoulder pad, Set of "O" rings
• LEDs indicate whether phase sequence is correct or reversed as well as
Optional 2417(Water proof Leakage Clamp Meter)
open phase, if any. 7093(Cord for extension probe)
• Rated voltage from 100V to 600V AC.
9080(Carrying case[Aluminium])
A full set (deluxe version complete with aluminum carrying case and leakage clamp meter) is
available as Model 6020T or 6030T.

Optional Accessories
Accessories
•Model 2417 Water proof Leakage Clamp Meter
40 mm jaw diameter True RMS
200mA/ 2000mA/ 20A/ 200A/ 500A
•Model 7093 Cord for extension probe
This is used to connect the extension probe directly to the instrument.
You can then use the instrument without the cord reel module.
•Model 9080 Carrying case[Aluminum]
This is a hard case of rugged construction. Mainly available with MODEL 7088 MODEL 7089
the top grade version of the multifunction tester that comes with
the leakage clamp meter Model 2417.

Description Model No. MODEL 8083


Water proof Leakage Clamp Meter 2417
Aluminum carrying case 9080
Cord for extension probe 7093 MODEL 7090 MODEL 7091
56
KEW MULTI FUNCTION TESTERS
MODEL 6050 (LOOP+RCD)
New Low Cost 2 in 1 Combi Tester with Memory and Download
Results to PC by option Model 8212.

MODEL 6050(LOOP+RCD)

Loop impedance ranges 20/200/2000Ω


(Z reading)
Loop impedance ranges 200 and 2000Ω with 15mA of test current
without tripping RCDs
Max test current on loop ranges 3A (20Ω) / 15mA (200 and 2000Ω)
PSC / earth fault current ranges 200/2000A/20kA
RCD test AC type × 1/2 10, 30, 100, 300, 500, 1000mA
(Standard and selective) ×1 10, 30, 100, 300, 500, 1000mA
×5 10, 30, 100mA
Auto Ramp 10, 30, 100, 300, 500mA
RCD test A type 10, 30, 100, 300, 500mA
(Standard and selective)
RCD test currents multipliers × 1/2 × 1 × 5
(max 1000mA type AC)
(max 500mA type A)
RCD test time duration 1000ms: × 1/2 × 1 DC
200ms: × 5 DC (500mA) and × 1(1000mA)
• Kew Combitester provides the ultimate in Microprocessor technology of-
RCD ramp test From 20% to 110% of I∆n (AC type)
fering Loop and RCD tests with a comprehensive memory and download-
Contact voltage block (RCD) 50V and 25V
ing test results.
Contact voltage reading (RCD) 100.0V
• LOOP Impedance 200/2000 W range measurement is carried out using
Phase and earth RCD (without DC)
a test current of 15mA. This current will not trip RCD’s rated at 30mA or
(2 wires only) measurements LOOP
greater.
Working voltage for loop tests 20Ω : 230V+10%, -15%
• High resolution for low Loop Impedance (resolution of 0.01 W) on 20 W
200/2000Ω : 230V+10%, -15% and 400V+10%, -15%
range.
Working voltage for RCD tests 230V+10%, -15%
• Direct reading of Prospective Short Circuit Current (PSC) and earth fault
Voltage test 100~260V
current.
(LOOP 200/2000Ω, PSC 200A:100~440V)
• RCD tests at 0 and 180 degree phase angle switch permit quick tests and
Memory 300 memory locations
consistent readings.
PC software, connection cable Optional with MODEL 8212
• Test of a large kind of RCD’s:
Applicable standards IEC 61010-1 CAT.3 300V IEC 61557
Standard, Selective, AC and A (DC sensitive breakers).
IEC 61010-031, IEC 60529(IP54)
• Constant current source circuitry ensures that a fluctuating mains voltage
Power source R6P(1.5V)(AA)×8
does not affect the accuracy of readings.
Dimensions 186(L) × 167(W) × 89(D)mm
• RCD Ramp test in order to indicate the actual tripping current of RCD.
Weight 980g
• Contact Voltage Reading (UC). with two selectable contact voltage limits
Accessories included 7125(Molded plug test lead [EU])

6050 (LOOP+RCD)
(50 and 25V).
9147(Cord case)
• Visual indication of correct wiring status and automatic lock-out if test re-
Instruction manual 9121(Shoulder strap) R6P×8
sistors overheats.
Optional 7121A(Distribution board test leads)
• Designed to IEC61010-1, IEC61557 and high protection degree IP54.
8212-RS232C (RS232C adaptor with "KEW Report (Software)")
• The stored data can be transferred to PC via Optical Adaptor Model
8212-USB (USB adaptor with "KEW Report (Software)")
8212.

Optional Accessories
MODEL 8212-USB MODEL 8212-RS232C "KEW Report" Software for report
“KEW Report” transfers measurement data from
USB adaptor with “KEW Report (Software)” RS232C adaptor with “KEW Report (Software)” the KEW6050 to a PC via MODEL8212-USB or
MODEL

MODEL8212-RS232C.

System Requirements
• PC/AT compatible machine on which
Microsoft Windows® 2000/XP/Vista can operate.
8212

Specifications • Pentium 233MHz or more recommended.


• RAM 64Mbyte or more.
MODEL 8212-USB MODEL 8212-RS232C • XGA (1024×768) recommended.
Communication method USB Ver1.1 – • 20MB or more of free hard disk space recom-
MODEL

Driver type Virtual COM port – mended.


Communication speed 19200bps max. 9600bps max. • One free COM port or One free USB port.
• CD-ROM drive (necessary at installing)
Adaptor : 53(L)×36(W)×19(D)mm Adaptor : 61(L)×36(W)×19(D)mm
Dimensions ❈ Trade mark
Cable : 2m approx. Cable : 1.6m approx. ®
Windows is a registered trade mark of Microsoft
Operating temperature and humidity -10~+50°C 85%RH or less with no condensation 0~+40°C 85%RH or less with no condensation in the United States.
Pentium is a registered trade mark of Intel in the
Storage temperature and humidity -20~+60°C 85%RH or less with no condensation
United States.

57
KEW PORTABLE APPLIANCE TESTERS
6200/6202
MODEL 6200
RPE 20Ω+ / 20Ω-
RINS 200MΩ IEL 20mA IL 2mA VOLT
MODEL Protective conductor
resistance test Insulation resistance test Equivalent leakage current Contact current AC voltmeter
Measuring 0~19.99Ω Measuring 0~19.99/ Measuring 0~19.99mA Measuring 0~1.999mA Measuring 180~260V
range range 199.9MΩ range range range (50/60Hz)
(2ranges auto)
Resolution of 10mΩ Resolution of 10kΩ/ Resolution of 0.01mA Resolution of 0.001mA Resolution of 1V
measurement measurement 100kΩ measurement measurement measurement
Short circuit 200 Rated >500V DC Measuring 30V AC Internal 2kΩ
current ~250mA voltage (+50%/-0%) voltage resistance
DC Rated current >1mA Internal 2kΩ (RA Meter)
Open circuit ±5.0±0.4V Short circuit 14mA resistance
voltage DC current (max.) (RA Meter)
Accuracy ±(2%rdg Accuracy ±(2%rdg Accuracy ±(2%rdg Accuracy ±(2%rdg Accuracy ±(2%rdg
+3dgt) +3dgt) +3dgt) +3dgt) +3dgt)
General Supply voltage 230V±10%
Frequency 50/60Hz±1%
Dimensions 185 (L) × 167 (W) × 89 (D) mm
Weight 1kg
Applicable IEC 61010-1 CAT.3 300V Pollution degree2
standards IEC 60950 Safety of Information technology equipment
IEC 61326-1 EMC requirements
Accessories 7125(Power cord [EU]) 7129(Test leads with alligator clip)
7161(Flat test bar[black])
9147(Cord case) 9121(Shoulder strap) Instruction manual

The Model 6200/6202 is a hand-held portable appli-


MODEL 6202
ance tester, performing four functions to ensure the Safe- RPE 20Ω+ / 20Ω-
ty of Class1, Class2 and Class3 230V appliances. Protective conductor RINS 200MΩ IEL 20mA IL 2mA VOLT
resistance test Insulation resistance test Equivalent leakage current Contact current AC voltmeter
And also can measure the mains voltage. Measuring 0~19.99Ω Measuring 0~19.99/ Measuring 0~19.99mA Measuring 0~1.999mA Measuring 180~260V
Readings are displayed on a large liquid crystal display range range 199.9MΩ range range range (50/60Hz)
(LCD) below which are eight LEDs which unambiguously (2ranges auto)
display a pass or fail indication for threshold values dic- Resolution of 10mΩ Resolution of 10kΩ/ Resolution of 0.01mA Resolution of 0.001mA Resolution of 1V
tated by DIN VDE 0701/0702 measurement measurement 100kΩ measurement measurement measurement
Short circuit 200~250mA Rated >500V DC Measuring 30V AC Internal 2kΩ
This instrument is suitable for performing tests as required by the following standards. current DC voltage (+50%/-0%) voltage resistance
DIN VDE 0701-1 (240):2000 Repairing, modification and testing of electrical
equipment Open circuit ±5.0±0.4V Rated current >1mA Internal 2kΩ (RA Meter)
voltage DC Short circuit 14mA resistance
MODEL

DIN VDE 0702 : 2004 Periodic inspection for electrical equipment


current (max.) (RA meter)
Accuracy ±(2%rdg Accuracy ±(2%rdg Accuracy ±(2%rdg Accuracy ±(2%rdg Accuracy ±(2%rdg
+3dgt) +3dgt) +3dgt) +3dgt) +3dgt)
6200/6202

KEW 6201A I LINE


Current consumption
Measuring range 0~16A AC
General Supply voltage
Frequency
Dimensions
230V±10%
50/60Hz±1%
185 (L) × 167 (W) × 89 (D) mm
Resolution of 0.01A Weight 1kg
measurement Applicable IEC 61010-1 CAT.3 300V Pollution degree2
Accuracy ±(2%rdg standards IEC 60950 Safety of Information technology equipment
+3dgt) IEC 61326-1 EMC requirements
Accessories 7125(Power cord [EU]) 7129(Test leads with alligator clip)
7161(Flat test bar[black])
9147(Cord case) 9121(Shoulder strap) Instruction manual
KEW

KEW 6201A

RPE 20Ω Protective RINS 200MΩ Leakage current AC VOLT


6201A

Conductor resistance test Insulation resistance test test Mains voltage check
Measuring 0~15.00Ω Rating 250V/20MΩ 500V/20MΩ Measuring AC 0.1 Measuring 207~264V
range Measuring 0~19.99MΩ range ~19.99mA range
range
Resolution of 10mΩ Resolution of 10kΩ Resolution of 0.01mA Resolution of 1V
measurement measurement measurement measurement
Open circuit <AC 12V Output 250V DC 500V DC
voltage voltage (+20%/-10%) (+20%/-10%)
Measuring 10A AC @1MΩ @1MΩ
current nominal
value Short circuit 2.5mA DC or less Examination Max 15
The KEW 6201A is a portable appliance tester, perform- current time seconds
ing four functions to ensure the Safety of Class1 and Accuracy ±(3%rdg+5dgt) Accuracy ±(2%rdg+3dgt) Accuracy ±(3%rdg+5dgt) Accuracy ±(2%rdg+3dgt)
Class2 appliances. And also can measure the mains General Supply voltage 240V±10%
voltage. Frequency 50Hz±1%
Readings are displayed on a large liquid crystal display Dimensions 185 (L) × 167 (W) × 89 (D) mm
(LCD) below which are four LEDs which unambiguously Weight 1.2kg(only the instrument body)
display a pass or fail indication for threshold values dic- Applicable IEC 61010-1 CAT.3 300V Pollution degree2
standards IEC 61326-1 EMC requirements
tated by AS/NZS 3760.
Accessories 7123(Power cord[AU]) 7129(Test leads with alligator clip)
This instrument is suitable for performing tests as required by the following standards.
AS/NZS 3760:2003 In-service safety inspection and testing of electrical equip-
7161(Flat test bar[black]) 7140(Adapter for extension cord)
ment. 9147(Cord case) 9121(Shoulder strap) Instruction manual
58
KEW POWER METERS
MODEL 6300 COMPACT POWER METER

Everything required for power consumption and


energy-saving analysis!!
RMS

6300MODEL
12 kinds of power measurements 4 types wiring system
Voltage (RMS), Current (RMS), active power, apparent power, reactive 1 phase - 2 wire (1ch), (2ch), (3ch)
power, active energy, apparent energy, ✻reactive energy, power factor 1 phase - 3 wire
(cos θ), frequency , demand measurement, current flowing on the neutral 3 phase - 3 wire
line (Only on3 phase 4 wire measurement) 3 phase - 4 wire

Regenerative electric power can be measured Direct communication with PC by USB connection
Detection of consumption power and regenerative electric power.
Regenerative electric power: This is the electric power which is gener- The interface for compact flash card (CF card) is
ated by private power generator, and is supplied to electric power com- equipped.
pany. An external memory up to 1GB or less can be used.

The electric power and the power factor for each


phase can be confirmed
Monitoring of operation for each phase. What “Demand Function” is
Recording internal can be set between 1 second "DEMAND" is the function to give the alarm when the power
and 1 hour consumption nearly exceeds the value during the preset interval.
1/2/5/10/15/20/30 second/seconds MODEL 6300 will warn by the buzzer sound and by the back light
1/2/5/10/15/20/30 minute/minutes 1 hour blinking, when the value predicted at the inspection cycle within the
interval exceeds the target value.
Demand measurement Demand function is widely used in Japan among different fields such
Buzzer sounding and backlight blinking give warning not to exceed the as construction company, factory, building maintenance company,
pre-setting demand target value. hospital, hotel, etc., who need to consume the large electrical power.
For example, 300kW, 500kW or 600kW on an annual basis.
Double power supply system AC line and Alkaline Therefore, they naturally need to monitor the total consumption of
size AA battery LR6 : 6 pcs. the power in order to save their power as low as possible.
Continuous 7 hours can be measured by using batteries Now, the demand function being provided in our Power Meter
MODEL 6300 is quite useful and effective as simplified monitoring
Display 3 different data simultaneously on large system.
screen.
59
KEW POWER METER
CF card (operation check has completed) Max number of data (reference)
Supplier Model Capacity Internal
Data saved in: CF card memory
SanDisk Corporation SDCFB-32 32MB
SDCFB-64 64MB Capacity 32MB 64MB 128MB 256MB 512MB 1GB 128kB
SDCFB-128 128MB Instantaneous measurement 100,000 200,000 400,000 800,000 1,600,000 3,125,000 1,000
SDCFB-256 256MB data data data data data data data
SDCFB-512 512MB Integration / demand 1 sec. 7 hours 14 hours 28 hours 56hours 112 hours 219 hours 4 minutes
SDCFG-1 1GB measurement interval 1 min. 18 days 36 days 72 days 144 days 288 days 1 year or more 4 hours
Adtec Co., Ltd. AD-CFG32 32MB 30 min. 1 year or more 5 days
AD-CFG64 64MB In case that no file exist in the CF card.
AD-CFG128 128MB
AD-CFG256 256MB
AD-CFX40T1G 1GB
BUFFALO Inc. RCF-X128MY 128MB MODEL 6300
RCF-X256MY 256MB Measurements and Voltage, Current, Active power, Apparent power, Reactive power,
RCF-X1GY 1GB parameters Active energy, Apparent energy, *Reactive energy,
Company name and model name are the trademark or the registered trademark.
Power factor(cos θ), Neutral current, Frequency meter.
Wiring connections 1P 2W, 3P 4W, 3P 3W, 1P 3W
Voltage [RMS]
User-Friendly "KEW POWER PLUS 2" is supplied Ranges 150.0 / 300.0 / 600.0V AC
Simple setting for all functions by clicking.
Effective input range 10~110% of Rating range
Easy setting for date, month and year with calendar.
Display range 5~120% of Rating range
The recorded data can be downloaded with the CSV file, and the data
analysis processing including waveform can be done by EXCEL. Crest factor up to 2.5
Accuracy ±0.3%rdg ±0.2%fs [45~65Hz]
System requirements
PC with CPU : Pentium2 200MHz or higher
Operating system : Windows 2000/XP/Vista
Current [RMS]
Memory : 32MB or more
Display : Resolution 800 × 600 dots, 65536 colors or more
Ranges 8128( 50A type ) : 5 / 10 / 20 / 50A
Hard-disk space required : 10MB or more
8127( 100A type ) : 10 / 20 / 50 / 100A
*Windows is a registered trademark of Microsoft in the United States.
®

*Pentium is a registered trademark of Intel in the United States.


8126( 200A type ) : 20 / 50 / 100 / 200A
8125( 500A type ) : 50 / 100 / 200 / 500A
Optional 8124( 1000A type ) : 100 / 200 / 500 / 1000A
8129( 3000A type ) : 1000 / 3000A
Effective input range 10~110% of Rating range
Load current type Display range 1~120% of Rating range
Crest factor up to 3.0 (with 90% fs or less)
Accuracy ±0.3%rdg ±0.2% fs + Clamp sensor accuracy [at 45~65Hz]
Active power
Accuracy ±0.5%rdg ±0.2%fs + Clamp sensor accuracy [at 45~65 Hz]
Effect of power factor ±1.0%rdg cos θ=±0.5 (PF=1)
Frequency
KEW 8129 MODEL 8128 MODEL 8127 Display range 40~70Hz
Accuracy ±3dgt
Flexible clamp sensor Clamp sensor Clamp sensor
MODEL

Accuracy precondition PF=1, Sine wave, 23˚C±5˚C


Max φ 150mm AC3000A φ 24mm AC5A(max50A) φ 24mm AC100A
Integration time for 1/2/5/10/15/20/30 Seconds 1/2/5/10/15/20/30/60 Minutes
8129-01 (for 1ch)
8129-02 (for 2ch) recording function
6300

8129-03 (for 3ch) Display update period 1 second


Operating temperature 0~+50˚C, less than 85% RH (without condensation)
and humidity ranges
Storage temperature and -20~+60˚C, less than 85% RH (without condensation)
humidity ranges
PC communication interface USB
MODEL 8126 MODEL 8125 MODEL 8124 CF card interface Compact flash card (Standard type 32/64/128/256/512MB/1GB)
Clamp sensor Clamp sensor Clamp sensor Applicable standard IEC 61010-1 CAT.3 600V
φ 40mm AC200A φ 40mm AC500A φ 68mm AC1000A AC Line : 100~240V±10% (50/60Hz)
Power supply
DC Battery 9V : LR6 × 6(Battery life approx. 7h)
Dimensions 175(L) × 120(W) × 65(D) mm
Weight Approx. 800g (including batteries)
Accessories 7141(Voltage test lead set : 4pcs) 7148 (USB cable)
7170(Power cord) 8319(CF Card reader)
8307(Compact flash card [128MB]) 9125(Carrying case)
KEW POWER PLUS 2(PC Software ) Batteries × 6 Quick manual
Optional 8124,8125,8126,8127,8128(Load current clamp sensor)
8129 (Flexible clamp sensor), 7198 (Small clips adaptor)
MODEL 7198 MODEL 8312 MODEL 9132 8322 (Compact flash card[256MB]), 8323 (Compact flash card[1GB])
8312 (Power supply adaptor), 9132 (Carrying case with magnet)
Small clips adaptor Power supply adaptor Carrying case with magnet
*
Ê"ÕÌ«ÕÌʜ˜Þ

Set Model
Consists of:
Model Clamp sensor
MODEL 6300-00       ー
6300 x 1
MODEL 6300-01 MODEL 8125(φ40:500A) × 3 7141(Voltage test lead set : 4pcs) × 1
MODEL 6300-02 MODEL 8125(φ40:500A) × 2 7148(USB cable) × 1
MODEL 6300-03 MODEL 8124(φ68:1000A) × 3 7170(Power cord) × 1
MODEL 6300-04 MODEL 8124(φ68:1000A) × 2
8307(Compact flash card [128MB]) × 1
MODEL 6300-05 MODEL 8126(φ40:200A) × 3
MODEL 6300-06 MODEL 8126(φ40:200A) × 2
8319(CF card reader)
MODEL 6300-07 MODEL 8127(φ24:100A) × 3 9125(Carrying case) × 1
MODEL 6300-08 MODEL 8127(φ24:100A) × 2 PC Software × 1
MODEL 6300-09 MODEL 8128(φ24:5A) × 3 Batteries × 6
MODEL 6300-10 MODEL 8128(φ24:5A) × 2 Photo:6300-01
Quick manual × 1
60
KEW POWER METERS
KEW 6310 POWER QUALITY ANALYZER

To control completely power quality


and power consumption (energy)!
RMS

Can measure Flicker in accordance to IEC61000-4-15 and


EN 50160 standards. Using our Flicker sensor, available as
optional accessory, Pst value (short term severity in 10 min-
utes value) and the Plt value (long term severity in 2 hours
value) can be measured.

● 12 kinds of Power Measurements for Power Control and Appli-


cable to Power Quality Control including Harmonics Analysis.
● One click easy-to-use operation helps complicated setting and
processing of large data through the setting / analyzing software
provided as accessory.
● Direct communication with PC via USB cable.

● Built-in Input / Output Function of external signal enables the sig-


nal transmission to alarms.
● 2-way power supply by AC and Battery, and Nickel hydrogen
battery usable with rechargeable function.

● Pull / Insert of CF card possible whenever on recording under the


function of memory backup device (1GB usable).
● Can monitor insulation at leakage current by using optional leak
clamp sensors.
● Built-in Print Screen Function enables to record display screen (Re-
cords 512 screens by using CF card: 1 screen 40KB).
● Can display Waveform and Vector, and can confirm the wiring
connection, too.

6310
● Complies fully with International Safety Standards IEC61010-1
CAT.3600V.

KEW
KEW 6310

Wiring connections 1P 2W, 1P 3W, 3P 3W, 3P 4W Frequency meter 40~70Hz


Measurements and Voltage, Current, Frequency, Active power, Reactive power, range
parameters Apparent power, Active energy, Reactive energy, Apparent energy, Internal memory 1.8MB (Measurement file [CSV] ×6 blocks,
Power factor (cos θ), Neutral current, Demand, Harmonics, Screen file [BMP] ×7 blocks, Configuration file [KAS] ×20 blocks)
Quality (Swell/Dip/Instantaneous stop, Transients/Over voltage, Display 320×240 (RGB) Pixel, 3.5-inch color STN display
Inrush Current, Unbalance Rate), Phase advance condenser Temperature & 23˚C±5˚C, Relative humidity 85% or less (no condensation)
IEC Flicker [Pst (1 min)*, Pst, Plt] *Pst can be shown in details for 1 minute intervals. humidity range
Other functions Digital output function, External communication function, Storage temperature -20˚C±60˚C, Relative humidity 85% or less(no condensation)
Scaling function & humidity range
Voltage [RMS] Operating temperature 0˚C±40˚C, Relative humidity 85% or less(no condensation)
Range 150 / 300 / 600 / 1000V & humidity range
Allowable input 10~110% of each range PC Card type Compact flash card (Capacity: 32 / 64 / 128 / 256 / 512MB / 1GB)
Display range 5~120% of each range Applicable standards IEC 61010-1 CAT.3 600V Pollution degree 2
Crest factor 2.5 or less (100% or less of each range) IEC 61010-031, IEC 61326
Accuracy ±0.3%rdg ±0.2%f.s. (sine wave, 45~65Hz) Power supply AC 100V~240V±10% (45~65Hz)
Current [RMS] Alkaline size AA battery LR6 (9V 1.5V × 6) or Ni-MH (HR15-51)
Range 8128 ( 50A type ): 1 / 5 / 10 / 20 / 50A Dimensions 175(L)×120(W)×68(D) mm
8127 ( 100A type ) : 10 / 20 / 50 / 100A Weight approx. 900g (including batteries)
8126 ( 200A type ) : 20 / 50 / 100 / 200A Accessories 7141(Voltage test lead set), 7148 (USB Cable), 7170 (Power Cord)
8125 ( 500A type ) : 50 / 100 / 200 / 500A 8307 (Compact flash card [128MB]), 8319 (CF Card reader)
8124 ( 1000A type ) : 100 / 200 / 500 / 1000A 9125 (Carrying case), Input terminal plate (6-kind)
8129 ( 3000A type ) : 300 / 1000 / 3000A Alkaline size AA battery (LR6) × 6, Cable marker × 32
Allowable input 10~110% of each range KEW PQA MASTER (PC Software), Quick manual
Display range 1~120% of each range Optional 8124, 8125, 8126, 8127, 8128 (Load current clamp sensor)
Crest factor 3.0 or less (90% or less of each range) 8129 (Flexible clamp sensor)
Accuracy ±0.3%rdg ±0.2%f.s. + Accuracy of Clamp sensor (sine wave, 45~65Hz) 8146, 8147, 8148 (Leakage & Load current clamp sensor)
Active power 8141, 8142, 8143 (Leakage clamp sensor)
Range Depending on combinations of (V Range) x (A Range) 7198 (Small clips adaptor)
Accuracy ±0.3%rdg ±0.2%fs + Accuracy of Clamp sensor 8322 (Compact flash card [256MB])
(Power factor 1, Sine wave 45~65 Hz) 8323 (Compact flash card [1GB]) 8325F (Flicker sensor)
Influence of power factor ±1.0% rdg (reading at power factor 0.5 against power factor 1) 8312 (Power supply adaptor) 9132 (Carrying case with magnet)
61
KEW POWER METERS
Power Consumption Power Quality Control
(Energy) Control

Instantaneous value mea-


surement / saving
Measures Current / Voltage / Instan-
taneous averaged value of Power
etc. / Maximum value / Minimum
value.

Wave Range Measurement / Saving


Integration value measure- Displays vector / waveform corresponding to voltage and current of
ment / saving each channel.

Measures Active power energy /


Apparent power energy / Reactive
power energy. Harmonics Measurement /
Saving
Measures and analyzes harmonics
contents of current and voltage of
each phase.
Demand value measure-
ment / saving
Sets Demand target value and mea-
sures Demand value from start to stop
of measurement. Can warn with digital
output terminal when the set value Quality
exceeds the target value. Can measure Swells / Dips / Inter-
ruptions, Transients, Inrush current,
Unbalanced, and can simulate power
factor correction with capacitor banks.

Designed For Various Wiring Systems


Single Phase 2 wires (4 system load measurement possible),
Single Phase 3 wires (2 system load measurement possible),
Three Phase 3 wires (2 system load measurement possible),
Three Phase 4 wires. CF Card Interface Loaded
Easy-To-Use Clamp type Setting External Memory up to 1GB Available.*2
Voltage Input Terminals (Clamp Sensors: Option) Recordable Number of Data Point / Approx. Time

Destination to save data CF Card Internal Memory


Capacity 32MB 64MB 128MB 256MB 512MB 1GB 1.8MB
1sec 15H 1D 2D 5D 10D 20D 7min
Instantaneous value measurement 1min 10D 20D 1M 2M 5M 10M 2H
30min 10M 1Y Over 1Y Over 1Y Over 1Y Over 1Y 2D
KEW

1sec 6H 13H 1D 2D 4D 8D 3min


Integration value measurement 1min 7D 15D 1M 2M 4M 8M 1H
The Instrument automatically rec-
6310

30min 7M 1Y Over 1Y Over 1Y Over 1Y Over 1Y 1D


ognizes clamp sensors connected 1sec 4H 8H 17H 1D 2D 5D 2min
(Easy-to-use setting). DEMAND measurement 1min 6D 12D 24D 1M 3M 6M 1H
30min 6M 1Y Over 1Y Over 1Y Over 1Y Over 1Y 1D

Can monitor insulation at leakage 10sec 1D 3D 7D 14D 28D 1M 20min

current by using leakage clamp WAVE range 1min 10D 21D 1M 2M 5M 11M 2H
30min 10M 1Y Over 1Y Over 1Y Over 1Y Over 1Y 2D
sensors (Option).
15sec 3D 7D 15D 1M 2M 4M 44min

Current Input Terminals Harmonic anaysis 1min 15D 1M 2M 4M 8M 1Y 2H

(With cover) 30min


1sec
1Y
2D
Over 1Y
5D
Over 1Y
11D
Over 1Y
22D
Over 1Y
1M
Over 1Y
2M
3D
32min
Swell / Dip / Int measurement *3 1min 5M 11M 1Y Over 1Y Over 1Y Over 1Y 1D
30min Over 1Y Over 1Y Over 1Y Over 1Y Over 1Y Over 1Y 1M

USB Terminal Transient measurement *3


1sec
1min
3D
6M
6D
1Y
12D
Over 1Y
24D
Over 1Y
1M
Over 1Y
3M
Over 1Y
35min
1D
30min Over 1Y Over 1Y Over 1Y Over 1Y Over 1Y Over 1Y 1M
1sec 2D 5D 11D 22D 1M 2M 32min
Inrush current measurement *3 1min 5M 11M 1Y Over 1Y Over 1Y Over 1Y 1D
30min Over 1Y Over 1Y Over 1Y Over 1Y Over 1Y Over 1Y 1M
1sec 21H 1D 3D 7D 14D 27D 10min
Digital Output Terminal *1 Unbalance rate 1min 14D 29D 1M 3M 7M 1Y 2H
30min 1Y Over 1Y Over 1Y Over 1Y Over 1Y Over 1Y 3D
(1ch) *Open Collector Output
Flicker *4 1min 7M 1Y Over 1Y Over 1Y Over 1Y Over 1Y 1D
Transmit the signal to an alarm device.
1sec 15H 1D 2D 5D 10D 19D 7min
Capacitance calculation 1min 10D 20D 1M 2M 5M 10M 1H
30min 10M 1Y Over 1Y Over 1Y Over 1Y Over 1Y 2D
Measurement data file (CSV) 6
Max number of file Graphics file (BMP) 512 7
Configuration file (KAS) 20

CF card Capacity 32MB 64MB 128MB 256MB 512MB 1GB


(operation check SanDisk
has completed) SDCFB-32 SDCFB-64 SDCFB-128 SDCFB-256 SDCFB-512 SDCFG-1
Corporation
Adtec Co., Ltd. AD-CFG32 AD-CFG64 AD-CFG128 AD-CFG256 — AD-CFX40T1G
Analogue Input Terminal BUFFALO Inc. — — RCF-X128MY RCF-X256MY — RCF-X1GY

(2ch : DC 50m/500m/5V) * In case that no file exist in the CF card or the Internal memory.where: H= hour(s), D=day(s),
M=month(s), Y=year(s)
* CF Card with more or less capacity other than listed above cannot be used with this instrument.
* Company name and model name are the trademark or the registered trademark.
* A Compact Flash Card (CF card) may not operate properly even if any of the above are used due to
manufacture’s specification change, etc. The use of supplied CF Card or optional Kyoritsu CF Card
CF Card Connector is recommended.
*1 The example of digital output is reference only. Please use the function according to customer’s use.
Can take out and put in CF card whenever *2 Downloading data from CF cards needs the optional card reader (8319) or card readers being on sale.
on recording under the function of memory *3 Assumed one event occur per minute and calculated.

62
*4 Flicker measurement function is only available with ver.2.00 or later.
backup device.
KEW POWER METERS
Equipped with the Flicker measurement function
Flicker can be measured by using flicker sensor KEW8325F of the option.
V measurement
Pst(1min) measurement
Plt measurement

In accordance to IEC61000-4-15:1997+A1:2003 and EN50160 standard.


Pst value (short term severity, ten minute period) and the Plt value (long term severity, two hour period) can be measured.
In addition, the Pst can be shown in detail for 1 minute intervals.

Attention for KEW6310 customers :


Flicker measurements are possible with firmware of KEW6310 upgrade (Ver.2.01), PC software PQA Master upgrade (Ver. 2.01) and an
optional accessory Flicker sensor KEW8325F.

Function of KEW PQA MASTER for easy-to-use setting and analyzing!


Simply connect KEW6310 and PC via USB, then one click for easy-to-use setting!
Built-in navigation function (W / HELP FUNCTION) helps you whenever you need.

SETTING FUNCTION ANALYSIS FUNCTION


Downloaded CSV file data Select necessary data Data list display
can be processed easily
with spreadsheet like Ex-
cel etc.

6310KEW
Harmonics Level Display Phase Angle Display Waveform Display

Analysis Soft
Supplied ! What is Flicker?
Flicker is an impression of unsteadiness of visual sensation
induced by a light stimulus whose luminance or spectral distri-
bution fluctuates with time. This depends on the frequency and
magnitude of light change and on the observer. Above a certain
threshold, flicker becomes disturbing for human beings. Flicker
is caused by periodic voltage fluctuations and generally not by
instantaneous voltage fluctuation like a swell or a dip.
Flicker origins
Origins of voltage fluctuation causing flicker are arc furnaces, welding machines, oil pres-
sure elevators (lifts), cranes, excavators and other heavy fluctuating loads.
Direct Data Transmission to PC via USB Impact of Flicker to equipment
◆ Fluctuating brightness of an incandescent lamp, a mercury lamp, a PC monitor, TV
Easy-to- use setting- up and analyzing with KEW screen, etc.
PQA MASTER supplied. ◆ Possible reduction of motor torque.
【System requirements】 ◆ Possible loss of data on a PC.
PC with CPU: Pentium3 500MHz or higher and with operating system of Win- Counter Measurements of Flicker
dows®2000/XP/Vista
Memory: 64Mbyte or more ◆ Increasing the short circuit power of the supply.
Display: Resolution 800 x 600 dots, 65536 colors or more ◆ Introduction of a Flicker compensator.
Hard-disk: Space required 100Mbyte or more ● Active filter system.
Others: With CD-ROM drive and USB driver ● Reactor phase control system by thyristor.
* Windows® is a registered trademark of Microsoft in the United States.
● Capacitor switching control system by thyristor.
63
* Pentium is registered trademark of Intel in the United States.
KEW POWER METERS
Optional Accessories
Load current clamp sensors
KEW 8129 MODEL 8128 MODEL 8127 MODEL 8126 MODEL 8125 MODEL 8124
8129-01 (for 1ch) / 8129-02 (for 2ch)
/ 8129-03 (for 3ch)

MAX
AC3000A
φ150 )%# !#! φ24 )%# !#! φ24 )%# !#! φ40 )%# !#! φ40 )%# !#! φ68 )%#

Leakage & Load current clamp sensors Leakage current clamp sensors
KEW 8146 KEW 8147 KEW 8148 MODEL 8141 MODEL 8142 MODEL 8143

!#! φ24 )%# !#! φ40 )%# !#! φ68 )%# !#M! φ24 )%# !#M! φ40 )%# !#M! φ68 )%#

∗8141/8142/8143 and 8146/8147/8148 cannot be used for power measurements.

Small clips adaptor Carrying case with magnet


MODEL 7198 MODEL 9132
KEW
6310

Power supply adaptor Flicker sensor


MODEL 8312 KEW 8325F

Set Model
-ODEL #LAMPSENSOR
Consists of:
a[mLIGFCFF     ー 6310 × 1
a[mLIGFCFG  ! s 7141 (Voltage test lead set)
a[mLIGFCFH  ! s 7148 (USB cable)
a[mLIGFCFI  ! s 7170 (Power cord)
a[mLIGFCFJ  ! s 8307 (Compact Flash card [128MB])
a[mLIGFCFK  ! s 8319 (CF card reader)
a[mLIGFCFL  ! s 9125 (Carrying case)
a[mLIGFCFM  ! s KEW PQA MASTER (PC software)
a[mLIGFCFN  ! s Input terminal plate (6-kind)
a[mLIGFCFO  ! s Quick manual
a[mLIGFCGF  ! s Alkaline size AA battery (LR6) × 6
a[mLIGFCGG   s Cable marker × 32
a[mLIGFCGH   s photo:6310-01

64
KEW OTHERS
MODEL 5201 DIGITAL ILLUMINOMETER

MODEL 5201

Ranges 0.1~19990Lux(automatic 3 range switching)


Accuracy ±5%rdg±1dgt
Measuring time 2 times per second
Temperature humidity ±3%(at 20°C)
characteristics
Angular incident 10° Less than ±1.5%
light characteristics 30° Less than ±3%
60° Less than ±10%
80° Less than ±30%
Spectral response Closely related to the spectral
characteristics luminous efficiency (of a standard observer).
Power source 6F22(9V) × 1
Dimensions 166(L) × 68(W) × 32(D)mm
Weight 180g approx.
Accessories Photocell cover
6F22 × 1
Soft carrying case
Instruction manual

• Model 5201 is a highly portable and compact digital illuminometer for


measuring illuminance from 0.1 to 19,990 Lux, with auto range switching.
• The digital display is held for a preset time (about 20 seconds) and, there-
fore, facilitates reading, recording and measuring in any direction.

MODEL 5202 DIGITAL LIGHT METER


MODEL 5202

Ranges 0.1~19990Lux
Accuracy Lux Accuracy
(23°C±5°C) 200 ±(4% rdg+5 dgt)
2000 ±(4% rdg+5 dgt)
20000 ±(5% rdg+4 dgt)
Current consumption 2mA approx

5201
Response time 2.5 times / sec.
Operating temperature range 0~50°C Below 80% RH
Storage temperature range -10°C~60°C
Angular incident

MODEL
30°Less than ±3% 60°Less than ±10% 80°Less than ±30%
light characteristics
Power source 6F22(9V) × 1
Dimensions Meter:148(L) × 71(W) × 36(H)mm
Light receiving sensor:85(L) × 67(W) × 32(H)mm
Weight 270g approx.
Accessories Carrying case × 1
6F22(9V) × 1
Photocell cover × 1
Instruction manual × 1
5202
• 3 ranges changeable from low to high illuminance.
(200/2000/20000Lux)
• Data hold function.
MODEL

• Digital light meter with separate light receiving sensor and meter.

65
KEW OTHERS
5500
ceZ[bKKFF
Portable Infrared 2ANGES

—#^—#
MODEL Thermometer $ETECTINGELEMENT 4HERMOPILE
3PECTRALRANGE ^MM
Model 5500 is non-contact infrared ther- -EASURINGDIAMETER FATADISTANCEOFMM
mometer with laser sighting. -EASURING ÒRDGÒ—#
ACCURACY WHICHEVERISTHEGREATERATANAMBIENTTEMPERATUREOF—#
2EPEATABILITY 7ITHINÒ—#
2ESPONSETIME SECONDRESPONSE
#OLLIMATION ,ASERBEAMMARKSTHECENTEROFTHEAREAMEASURED
"EAMDIAMETER MMAPPROXATADISTANCEOFM
"EAMOUTPUT ,ESSTHANM7 NM )%##LASS
• Simple temperature measurement from -40° $ISPLAYINDICATIONS #URRENTREADING -AXIMUM -INIMUM 2EADINGHOLD
C to 500°C %MISSIVITY !LARMPOINT ,OWBATTERY
• Laser sight pinpoints measured spots. !UTOPOWEROFF !UTOMATICALLYSHUTSPOWEROFFIFNOKEYISPRESSEDFORSECONDS
• Palm size,lightweight 180g only. !LARM 5PPERLIMITALARMWITHABEEPER
• Automatic power off for saving battery life. ,OWERLIMITALARM OPTIONAL
• Maximum or minimum temperature display. %MISSIVITY 3ELECTABLEFROM$!2+ "2)'(4
• Audible buzzer high alarm standard. CORRECTION AND&2%%VARIABLEBETWEENAND INITIALVALUEIS
• Emissivity adjustable from 0.30 to 1.90 in $ISPLAYILLUMINATION !UTOMATICBACKLIGHT
0.01 steps. 0OWERSOURCE ,26 s
• Backlight. "ATTERYLIFE APPROXHOURSFORCONTINUOUSUSE
$IMENSIONS , s7 s$ MM
7EIGHT GAPPROX

Distance to Spot Size !CCESSORIES ,2¾3OFT6INYL#ASE)NSTRUCTIONMANUAL

21
Laser Beam Caution
Please do not aim or direct laser
90 45 toward faces.
500 On measurement of targets like as
1000 glossy metal, be careful with influ-
Unit: mm ences by the reflection from it.

5510
MODEL 5510
Waterproof handheld Measuring range -40°C~300°C
MODEL Infrared Thermometer Detecting element Thermopile
Spectral range 6.5µm or more
Display resolution 0.5°C 1°C for below -20°C and over 100°C
MODEL

Measuring accuracy When the ambient temperature is 25±2°C and the emissivity (ε) is 1,
0~300°C :bigger value of either of ±1% of the
5500

measured value ±1dgt or ±2°C ±1dgt.


0~-30°C :±3°C ±1dgt
below -30°C :±5°C ±1dgt
Repeatability within 1°C ±1dgt
Response 1 sec(90% response)
Measuring diameter (45mm/500mm(Optical sensitivity: 90%)
Collimation Before shipment: 0.95. The value can be altered between 0.8
and 1.0 with the slide switch at the lower part of the battery
compartment(by 0.05 steps).
Laser beam(650nm 1mW JIS class2)specifies the center.
Water-proof property IP67
MODEL

Auto power off If no key is pressed for 30 seconds, the power is shut off
automatically.
Shock proof This instrument or its function/performance will not be damaged
5510

• Safe even if getting wet. Dustproof and waterproof structure of IP67. property even if it is dropped on the p tile floor from 1 meter high.
• Possible to wash Operating temperature 0~50°C
• Please feel secure to use the product on the spot, made from ABS resin of Operating humidity 90% rH and below(no condensation)
antibacterial specification. Storage -20~55°C(no condensation)(Note): In the case of longterm
• Shock-proof structure: No damage even if dropped from the height of 1m. temperature storage, the batteries should be removed.
• With auto-power-off function, preventing consumption of the battery Battery 2 AAA alkaline cell batteries
• Wide Temperature Range of -40°C to 300°C Battery life Approximately 10 hours for continuous use
• Small and light: Possible to measure easily by one hand. Housing material ABS(antibacterial)
• Portable type: Convenient to carry Dimensions 120 × 60 × 54mm(Maximum value for each direction)
Weight Approx. 123g
Accessories 2 AAA alkaline cell batteries, instruction manual, strap
Approved standard CE marking:EMI EN61326 Class B EMS EN61326 Annex C

Relation of Distance and Measuring Diameter Stability:±5°C under EMC test environment at 25°C

Caution
90

45

17

5510 is one of the portable. IP-67


laser applied instruments which
are regulated by the consumer
product safety law. LASER RADIATION
MAX 1.0m W 650nm

500 Do not look into the laser beam. CLASS 2 LASER PRODUCT

Do not aim the laser beam at CAUTIOUS


DO NOT STARE INTO BEAM
1000 human beings. PER IEC 60825-1(1997)

Keep the instrument out of


children's reach.

66
KEW OTHERS
MODEL 8030 DIGITAL PHASE INDICATOR with open phase checker

• Phase indicator designed to check the presence of open phase and


also the phase sequence by LED and buzzer at the same time.
• Small, lightweight, and portable.

MODEL 8030

CE Type Standard Type


Operational voltage 200~480V AC
Time limit for 200V : within 60 minutes
continuous 480V : within 4 minutes
Standard type Frequency response 20~400Hz
Applicable standards IEC 61010-1 CAT.3 300V
Pollution degree 2
Withstand voltage 2200V AC for 1 minute
Dimensions 82(L) × 59(W) × 23(D)mm
Weight 200g approx.
Cord 1m(R: red S : white T : blue)
Accessories 9070(Carrying case)
Pins for test leads
Instruction manual

CE type

MODEL 8031 PHASE INDICATOR with open phase checker

• Phase indicator designed to check the presence of open phase and


also the phase sequence by rotating disk and lamps.
• Can check a wide range of 3-phase power source from 110V to 600V.

MODEL 8031

CE Type Standard Type


Operational voltage 110~600V AC
Time limit for >500V : within 5 minutes
continuous
Standard type Frequency response 50/60Hz
Applicable standards IEC 61010-1 CAT.3 600V

8030
Pollution degree 2
Withstand voltage 5550V AC for 1 minute
Dimensions 106(L) × 75(W) × 40(D)mm
Weight 350g approx.

MODEL
Cord 1.5m(R : red S : white T : blue)
Accessories 9029(Carrying case)
Instruction manual

CE type

KEW 8031F PHASE ROTATION TESTER with fused test leads


8031
• KEW8031F is designed to check phase sequence.
Lamps provided on the unit will also tell you if a phase is open.
• Can check a wide range of 3-phase power source from 110V to 600V.
Sealed against dust, the unit ensures trouble-free performance.
MODEL

• Small, Lightweight and portable. Designed for maximum ease of opera-


tion and ruggedness.
• No exposed metal parts, Safety features are incorporated including the
instant push button switch operation.

a[mNFIG\

/PERATIONALVOLTAGE ^6!#
&USE !6&
4IMELIMITFOR 6WITHINMINUTES
8031F

CONTINUOUS
&REQUENCYRESPONSE (Z(Z
!PPLICABLESTANDARDS )%# #!460OLLUTIONDEGREE
7ITHSTANDVOLTAGE 6!#FORMINUTE
$IMENSIONS , s7 s$ MM
KEW

7EIGHT GAPPROX
#ORD M2RED3WHITE4BLUE
!CCESSORIES #ARRYINGCASE
)NSTRUCTIONMANUAL

67
KEW OTHERS

Demonstration Panels
To support sales promotion and user training, the Kyoritsu for marketing and educational purposes, such as sales force
sales promotion program has prepared 3 different demon- training, end users’ training, seminars, exhibitions, trade fairs
stration panels: Kew 8205A, Kew 8208 and Kew 8215. and schools of electrical engineering.
These lightweight portable demonstration panels can be used

KEW 8205A Multifunction and Safety Testers demo panel


This demonstrative panel is intended to demonstrate the use Multifunction testers and
specific instruments like Continuity, Insulation, Earth, Loop and RCD testers of Kyoritsu.
The panel simulates an electrical installation with TT and TN distribution systems, easy
selectable by a switch on the panel.
The tests that can be carried out are:
• Continuity Test of Protective and Equipotential conductors.
• Insulation Resistance Test.
• Earth Resistance Test (Volt-Ampere method).
• Earth Loop Test, including Prospective Short circuit Current (PSC) and Prospective
Fault Current (PFC).
• RCD Tripping Test.

$IMENSIONS , s7 s$ MM


7EIGHT KG

KEW 8208 Leakage demo panel


This panel demonstrates the use of Kyoritsu Leakage Clamp Meters in troubleshooting
nuisance tripping of RCD’s due to leakage currents.
It includes an RCD with bypass facilities and 5 downstream circuits. Each circuit can
KEW

simulate a fixed/variable leakage current by selecting an appropriate switch.


Using a Kyoritsu Leakage Clamp the overall leakage current can be found and the
8205

source of leakage current direction can be traced by clamping the conductors in each
circuit.
There can also be a combination of one or more leakage currents, for instance, it is
possible to simulate a situation of an RCD tripping due to two faulty circuits, one with a
fixed leakage current and the other one with variable leakage current (for example due
to humidity).

$IMENSIONS , s7 s$ MM


7EIGHT KG
KEW
8208

KEW 8215 All Clamps demo panel


This panel demonstrates the operation of all Kyoritsu AC, AC/DC and Leakage clamp
meters including the special open jaw AC/DC clamp meters like KEW FORK 2300R or
KEW MATE 2000 series.
It features the "actual size" photos of 3 different instruments. However for an effective
demonstration, real samples of these instruments should be attached to the panel using
a simple anti-theft cable supplied with the panel.
This panel generates approx: 15A AC and DC, 30 mA AC of leakage current, 12V AC,
15V DC and 10Ω. The current values can be measured by simply clamping the wires
KEW

or, for voltage and resistance values, touching the metallic test points on the panel with
the instrument test leads.
8215

$IMENSIONS , s7 s$ MM


7EIGHT KG

68
KEW SENSORS
Load current Clamp sensors

KEW 8129 MODEL 8128


8129-01 (for 1ch)
8129-02 (for 2ch)
8129-03 (for 3ch)

FLEXIBLE CLAMP SENSOR


CAN MEASURE UPTO
AC3000A HIGH CURRENT
!#!

MAX
AC3000A
φ150 )%# φ24 )%#

 FORCH  FORCH  FORCH 


#ONDUCTORSIZE MAXFMM F
2ATEDCURRENT ! !#!-AX!
/UTPUTVOLTAGE !2ANGE !#M6!#!M6! !#M6!
!2ANGE !#M6!#!M6! [-AXM6!] !#M6!
!2ANGE !#M6!#!M6!
!CCURACY ÒRDG^(Z ÒRDGÒM6(Z ÒRDGÒM6(Z^K(Z
0HASESHIFT WITHINÒ— WITHINÒ—^(Z
7ITHSTANDVOLTAGE !#6FORSECONDS !#6FORSECONDS
#ABLELENGTH:/UTPUTCONNECTOR 3ENSORPARTAPPROXM /UTPUTCABLEAPPROXM -).)$).0). !PPROXM-).)$).PIN
/PERATINGTEMPERATUREHUMIDITYRANGES ^ƒ# RELATIVEHUMIDITYORLESSNOCONDENSATION ^ƒ# LESSTHAN2(WITHOUTCONDENSATION
/UTPUTIMPEDANCE 7ORLESS !PPROX7
!PPLICABLESTANDARDS )%#  )%#  #!460OLLUTIONDEGREE )%# )%#  )%#  
#!46POLLUTIONDEGREE )%#
$IMENSIONS , ¾7 ¾$ MMEXCEPTFORPROTRUSIONS , s7 s$ MM
7EIGHT !PPROXG !PPROXG !PPROXG !PPROXG
!CCESSORIES )NSTRUCTIONMANUAL )NSTRUCTIONMANUAL )NSTRUCTIONMANUAL #ARRYINGCASE
/UTPUTCABLE ¾ /UTPUTCABLE ¾ /UTPUTCABLE ¾ )NSTRUCTIONMANUAL
#ARRYINGCASE #ARRYINGCASE #ARRYINGCASE #ABLEMARKER
/PTIONAL ­ "ANANAFADJUSTERPLUG %XTENSIONCABLE
!PPLICABLEMODELS      

MODEL 8127 MODEL 8126 MODEL 8125 MODEL 8124

8124/8125/8126/8127/8128/8129
!#! !#! !#! !#!

φ24 )%# φ40 )%# φ40 )%# φ68 )%#

#ONDUCTORSIZE F F F F


2ATEDCURRENT !#! !#! !#! !#!
/UTPUTVOLTAGE !#M6!!#M6! !#M6!!#M6! !#M6!!#M6! !#M6!!#M6!
!CCURACY ÒRDGÒM6(Z ÒRDGÒM6(Z
ÒRDGÒM6(Z^K(Z ÒRDGÒM6(Z^K(Z
0HASESHIFT WITHINÒ—^(Z WITHINÒ—^(Z
7ITHSTANDVOLTAGE !#6FORSECONDS !#6FORSECONDS
#ABLELENGTH/UTPUTCONNECTOR !PPROXM-).)$).PIN
/PERATINGTEMPERATURERANGES ^ƒ# LESSTHAN2(WITHOUTCONDENSATION
/UTPUTIMPEDANCE !PPROX7 !PPROX7 !PPROX7 !PPROX7
!PPLICABLESTANDARDS )%#  )%#   )%#  )%#  
#!46POLLUTIONDEGREE #!46POLLUTIONDEGREE
)%# )%#
MODEL

$IMENSIONS , s7 s$ MM , s7 s$ MM , s7 s$ MM
7EIGHT !PPROXG !PPROXG !PPROXG
!CCESSORIES #ARRYINGCASE )NSTRUCTIONMANUAL#ABLEMARKER #ARRYINGCASE )NSTRUCTIONMANUALCABLEMARKER
/PTIONAL "ANANAFADJUSTERPLUG %XTENSIONCABLE
!PPLICABLEMODELS  

69
KEW SENSORS
Leakage & Load current Clamp sensors

KEW 8146 KEW 8147 KEW 8148

!#! !#! !#!

φ24 )%# φ40 )%# φ68 )%#

#ONDUCTORSIZE F F F


2ATEDCURRENT !#! !#! !#!
/UTPUTVOLTAGE !#M6!!#M6! !#M6!!#M6! !#M6!!#M6!
!CCURACY ^! ^! ^!
ÒRDGÒM6(Z ÒRDGÒM6(Z ÒRDGÒM6(Z
ÒRDGÒM6(Z^K(Z ÒRDGÒM6(Z^K(Z ÒRDGÒM6(Z^K(Z
^! ^! ^!
ÒRDG(Z ÒRDG(Z ÒRDG(Z
ÒRDG(Z^K(Z ÒRDG(Z^K(Z ÒRDG(Z^K(Z
7ITHSTANDVOLTAGE !#6FORSECONDS
#ABLELENGTH/UTPUTCONNECTOR !PPROXM-).)$).PIN
/PERATINGTEMPERATURERANGES ^ƒ# LESSTHAN2(WITHOUTCONDENSATION
/UTPUTIMPEDANCE !PPROX7 !PPROX7 !PPROX7
!PPLICABLESTANDARDS )%#  )%#  
#!46POLLUTIONDEGREE )%#
$IMENSIONS , s7 s$ MM , s7 s$ MM , s7 s$ MM
7EIGHT !PPROXG !PPROXG !PPROXG
!CCESSORIES #ARRYINGCASE )NSTRUCTIONMANUAL#ABLEMARKER #ARRYINGCASE )NSTRUCTIONMANUAL#ABLEMARKER
/PTIONAL "ANANAFADJUSTERPLUG %XTENSIONCABLE
!PPLICABLEMODELS   

∗Cannot be used for power measurements.


KEW
8146/8147/8148

Load current Clamp sensors

KEW 8121 KEW 8122 KEW 8123

!#! !#! !#!

φ24 )%# φ40 )%# φ55 )%#


KEW

#ONDUCTORSIZE F F F


8121/8122/8123

2ATEDCURRENT !#! !#! !#!


/UTPUTVOLTAGE !#M6!!#M6! !#M6!!#M6! !#M6!!#M6!
!CCURACY ÒRDGÒM6(Z
ÒRDGÒM6(Z^K(Z
7ITHSTANDVOLTAGE !#6FORSECONDS !#6FORSECONDS
#ABLELENGTH/UTPUTCONNECTOR !PPROXM-).)$).PIN
/PERATINGTEMPERATURERANGES ^ƒ# LESSTHAN2(WITHOUTCONDENSATION
/UTPUTIMPEDANCE !PPROX7 !PPROX7 !PPROX7
!PPLICABLESTANDARDS )%#  )%#  )%#  
)%#   #!46POLLUTIONDEGREE )%#
#!46POLLUTIONDEGREE )%#
$IMENSIONS , s7 s$ MM , s7 s$ MM , s7 s$ MM
7EIGHT !PPROXG !PPROXG !PPROXG
!CCESSORIES #ARRYINGCASE )NSTRUCTIONMANUAL#ABLEMARKER #ARRYINGCASE )NSTRUCTIONMANUAL#ABLEMARKER
/PTIONAL "ANANAFADJUSTERPLUG %XTENSIONCABLE
!PPLICABLEMODELS  

70
KEW SENSORS
Leakage current Clamp sensors

MODEL 8141 MODEL 8142 MODEL 8143

!#M! !#M! !#M!

φ24 )%# φ40 )%# φ68 )%#

#ONDUCTORSIZE FMM FMM FMM


2ATEDCURRENT !#M! !#M! !#M!
/UTPUTVOLTAGE !#M6M!!#M6!
!CCURACY ÒRDGÒM6(Z
ÒRDGÒM6(Z^K(Z
7ITHSTANDVOLTAGE !#6(Z FORSECONDS
#ABLELENGTH/UTPUTCONNECTOR !PPROXM-).)$).PIN
/PERATINGTEMPERATURERANGES ^ƒ# LESSTHAN2(WITHOUTCONDENSATION
/UTPUTIMPEDANCE !PPROX7 !PPROX7 !PPROX7
!PPLICABLESTANDARDS )%#  )%#  #!46POLLUTIONDEGREE
$IMENSIONS , s7 s$ MM , s7 s$ MM , s7 s$ MM
7EIGHT !PPROXG !PPROXG !PPROXG
!CCESSORIES #ARRYINGCASE )NSTRUCTIONMANUAL #ARRYINGCASE )NSTRUCTIONMANUAL
/PTIONAL "ANANAFADJUSTERPLUG %XTENSIONCABLE
!PPLICABLEMODELS     

∗Cannot be used for power measurements.

8141/8142/8143
Voltage sensor, Flicker sensor

KEW 8309 KEW 8325F


Floating Voltage Can measure Flicker
can be measured in combination with
*Floating voltage : KEW 6310
phase to phase voltage
not grounded

MODEL

*KEW 5020-01: KEW5020 logger with KEW 8309(1pce.)

Max. input voltage AC 600Vrms(sin), 848.4Vpeak AC 600Vrms, 848.4Vpeak


8309

Input system Differential input (can measure floating voltage) Differential input
Output voltage AC 0~60mV (output/input : 0.1mV/V) AC 0~600mV (output/input: 1mV/V)
Measuring ranges 6~600V
Accuracy
±1.0%rdg±0.1mV (50/60Hz) ±0.5%rdg±0.1mV (50/60Hz)
KEW

(Frequency range)
Operating temperature
-10~50ºC, less than 85% RH (no condensation) 0~40ºC, less than 85% RH (no condensation)
and humidity ranges
Input impedance Approx. 3.4MW Approx. 3.2MW
Output impedance Approx. 180W Approx. 1kW
Location for use Altitude up to 2000m, Indoors Altitude up to 2000m in indoor
8325F

Cable length : Output connector Approx. 2m : MINI DIN 6PIN


Withstand voltage 5350V (rms 50/60Hz) for 5 sec. between measuring terminal and enclosure
IEC 61010-1 CAT.3 600V pollution degree 2 IEC 61010-1 CAT.3 600V pollution degree 2
Applicable standards
IEC 61010-031, IEC 61326 (EMC) IEC 61010-031, IEC 61326 (EMC)
Dimensions 87(L)×26(W)×17(D)mm (excluding protrusions)
KEW

Weight Approx. 135g


Accessories Instruction manual
Optional 7185 (Extension cable), 7197 (Small clips adaptor) 7197 (Small clips adaptor)
Applicable model 5020 6310
71
KEW SENSORS
Optional Accessories of Loggers,
Power Meter and Power Quality Analyzer
Applicable model table Voltage sensor
5000 5001 5010 5020 6300 6310
Sensor Load current 8121 K K KEW 8309
8122 K K
8123 K K Floating voltage
8124 K K K K can be measured
8125 K*1 K*1 K K *Floating voltage:
8126 K*2 K*2 K K Phase to phase voltage not
8127 K*3 K*3 K K grounded
8128 K K K K
8129 K*4 K*5 K K
Leakage current 8141*6 K K K K K
8142*6 K K K K K
* KEW 5020-01 : KEW 5020 logger with KEW 8309 (1pce.)
8143*6 K K K K K
Leakage & Load 8146*6 K K K
current 8147*6 K K K
8148*6 K K K Flicker sensor
Voltage sensor 8309 K

Test lead
Flicker sensor 8325F
7198 K
K
K
KEW 8325F
7197 K
Can measure Flicker
Adaptor 8312 K K
in combination with
8320 K K
Case 9119 K K K K KEW6310.
9132 K K
9135 K K K K
*1~5: Can use with after the following serial numbers.
*1: No.02637~
*2: No.00151~
*3: No.00181~
*4: No.8029792~
*5: No.8031560~
*6: Cannot be used for power measurement.

Power supply adaptor Small clips adaptor Carrying case with


MODEL 8312 MODEL 7198 magnet
Power source can be taken
through the measured line
Length : 650mm MODEL 9132
(100~240v) Capable to attach to the
test lead(MODEL 7141)
to have smaller clips.

* Can be connected to the M5 size screw used at the Easy-to-use setting with magnet on the steel
OPTIONAL ACCESSORIES

terminals of RCD/ELCB’s. plate etc. of switch board

Small clip adaptor AC adaptor (External power supply)


MODEL 7197 MODEL 8320
Length : 650mm

Adaptor to convert the crocodile clips • Appropriate for a longer


of the voltage sensor (8309) to smaller period of recording.
ones.
* Can be connected to the M5 size • Complies to
screw used at the terminals of stan- 90~264V(45~66Hz).
dard RCD/ELCB’s.

Up to 3 sensors can be packed into the hard


Carrying case[Hard] carry case. All the clamp sensors can fit in the Carrying case
MODEL 9119 case except for the KEW 8123 clamp sensor. MODEL 9135
Combinations available
4HE!VAILABLE.UMBERS

,OGGER 

#LAMPSENSOR(φ  –
#LAMPSENSOR(φ   –   

#LAMPSENSOR(φ –   –  

Dimensions : * Any clamp sensor (1 pc.) can be exchanged Dimensions :


327(L) × 310(W) × 120(D)mm with the voltage sensor (1 pc.). 250(L) × 270(W) × 216(D)mm

72
KEW ACCESSORIES
MODEL 7014 1,250mm MODEL 7019 1,500mm MODEL 7025 1,500mm
❋Output cord
Applicable model Applicable model Applicable model
2002PA 5402D 3001B
2002R 3111V
2003A 3165
2009A 3166
2010 6010A
2412 6010B
6015

Plug f7 Plug f4 Plug f4

MODEL 7058 1,500mm MODEL 7060 1,200mm MODEL 7061 1,100mm


❋Temperature probe ❋Output cords
Applicable model Applicable model Applicable model
3121 1106 8113
3122 1110
3123 2608A

Plug f4 Plug f4

MODEL 7066 1,100mm MODEL 7067 1,100mm MODEL 7073 2,120mm


❋2WAY Output cord
Applicable model Applicable model Applicable model
1106 2055 2805 2413F
1110 2056R 2413R
2004 2412
2006 2608A
2007A
2017
2027
2037
2040
2046R

Plug f4 Plug f4 f4

MODEL 7081 1,500mm MODEL 7082 1,100mm MODEL 7083 5,200mm


❋Guard cord ❋Lead for recorder ❋Lead for battery charging
Applicable model Applicable model Applicable model
3315 3124 3124
3321A
TEST LEADS

Plug f4 f4

MODEL 7084 5,000mm MODEL 7085 1,100mm MODEL 7088 1,530mm


❋Earth and guard leads Applicable model Applicable model ❋Test leads for phase indicator Applicable model
3124 1109 6020
6030

Plug f4 Plug f4
73
KEW ACCESSORIES
MODEL 7089 1,070mm MODEL 7090 1,070mm MODEL 7091
❋Test leads for earth reststance
Applicable model Applicable model
Applicable model
6020 6020
6030 6030 6020
6030

Green 5m
Yellow 10m
Red 20m

MODEL 7093 1,500mm MODEL 7095


❋Test leads for earth reststance
MODEL 7100
Applicable model Applicable model Applicable model
6020 4102A 4102A
6030 4102A-H 4105A
4105A 6017
4105A-H 6017F
6017 6018
6017F 6018F
6018
6018F Green 5m
Yellow 10m
Green 5m Red 20m
Yellow 10m
Plug f4
Red 20m Plug

MODEL 7103/7139 Line 1,000mm Earth 1,550mm MODEL 7107 1,100mm


❋Test leads with remote control swtich Applicable model
Applicable model
7103 7139
2002PA
3021 6018 3144A 2002R
3022 6018F 3145A 2003A
3023 3146A 2009A
3315 3161A
3316
7103 7139 3321A
3322A
3323A
6017
6017F
Plug Plug f4

MODEL 7115/7116 1,000mm MODEL 7121A 1,500mm


❋Extension probe Applicable model ❋Distribution board test leads Applicable model
7115 7116 4116A
4118A
TEST LEADS

3021 6018 3144A 4120A


3022 6018F 3145A 5406A
3023 3146A 6050
3315 3161A 6200
7115 7116 3316 6202
3321A
3322A
3323A
6017
6017F
Plug Plug

MODEL 7122A 1,220mm MODEL 7123/7124/7125/7126 1,500mm


Applicable model
Applicable model ❋Molded plug test lead
7123 7124 4116A 4120A
3005A
3007A 4118A 5406A
3131A 7123 (AU)
3132A
6011A 6201A

7125 7126 7125 (EU)


6050 6202
6200
7123 : (AU) Australian plug
7124 : (UK) British plug (13A)
7125 : (EU) European SHUKO plug
Plug f4 Plug 7126 : (SA) South african plug
74
KEW ACCESSORIES
MODEL 7127 1,570mm MODEL 7128 1,390mm MODEL 7129 1,450mm
❋Simplified measurement probe
Applicable model Applicable model Applicable model
4102A 5410 5410
4102A-H 6200
4105A 6201A
4105A-H 6202

MODEL 7132A 1,200mm MODEL 7133A 1,500mm MODEL 7141 3,000mm


(KSLP5)
Applicable model
(OMA DIEC)
Applicable model
❋Voltage test lead set Applicable model
6300
6011A 6010A 6310
6010B
6011A

MODEL 7146 190mm MODEL 7149/7150 Line 1,000mm Earth 1,550mm


Applicable model
❋Remote control switch set
❋Banana f4 adjuster plug Applicable model (7103 or 7139,7161,7131,8017,9120 or 9041)
8121 8146 7149 7150
8122 8147 3021 6018
3144A
8123 8148 3022 6018F
3145A
8124 3023
3146A
8125 3315
3161A
8126 7149 7150 3316
8127 3321A
8128 3322A
8141 3323A
8142 6017
8143 6017F
Plug f4

MODEL 7153A 1,220mm MODEL 7154A 1,220mm MODEL 7155A


Applicable model
❋Safety test leads Applicable model ❋Safety test leads ❋Safety test leads with fuse Applicable model
1106 2056R
1106 2040 1110 2412 7153A
1110 2046R 2004 2608A 7154A

TEST LEADS
2004 2055 2006 2805
2006 2056R 2017 3111V
2017 2412 2027 3165
2027 2608A 2037 3166
2037 2805 2040 6010A
2046R 6010B
2055 6016

Plug f4
Plug f4

MODEL 7156A 1,220mm MODEL 7157A MODEL 7158A


❋Safety test leads with fuse Applicable model ❋Safety crocodile clips ❋Safety crocodile clips for fuse
1106 2056R Applicable model Applicable model
1110 2412 7153A 7155A
2004 2608A 7154A 7156A
2006 2805
2017 3111V
2027 3165
2037 3166
2040 6010A
2046R 6010B
2055 6016

Plug f4

75
KEW ACCESSORIES
MODEL 7159A 1,220mm MODEL 7165 3,000mm MODEL 7166 1,500mm
❋Safety test leads with fuse ❋Line probe ❋Earth cord
Applicable model
Applicable model Applicable model
3125
1106 2056R 3125
1110 2412
2004 2608A
2006 2805
2017 3111V
2027 3165
2037 3166
2040 6010A
2046R 6010B
2055 6016

MODEL 7167 1,500mm MODEL 7168 3,000mm MODEL 7170 2,000mm


❋Guard cord ❋Line probe with alligator clip ❋Power cord
Applicable model Applicable model Applicable model
3125 3125
3128
6300
6310

MODEL 7185 3,000mm MODEL 7188 1,520mm MODEL 7196 1,550mm


❋Extension cable ❋Distribution board fuse ❋Test leads with remote
Applicable model test lead set Applicable model Applicable model
control switch
8121 8128 6016 6016
8122 8141
8123 8142
8124 8143
8125 8146
8126 8147
8127 8148

MODEL 7197 650mm MODEL 7198 650mm MODEL 7199 1,000mm


❋Small clip adaptor ❋Small clip adaptor Applicable model ❋Output cable Applicable model
Applicable model
8309 7141 8129
TEST LEADS

MODEL 7187/7218/7221/7222 1,230mm MODEL 7220 1,080mm


❋Power cord
7187 7218 Applicable model Applicable model
6016 1061
1062

7221 7222

7187 : UK plug
7218 : EU plug
7221 : SA plug
7222 : AU plug
Plug
76
KEW ACCESSORIES
MODEL 7224 1,500mm MODEL 7225 1,500mm MODEL 7226 3,000mm
❋Earth cord ❋Guard cord ❋Line probe
Applicable model Applicable model Applicable model
3128 3128 3128

MODEL 7227 3,000mm MODEL 7228 MODEL 7229


❋Line probe with alligator clip ❋Earth cord ❋Earth resistance test leads
Applicable model Applicable model Applicable model
3128 6016 4106

Green : 5m Green : 20m


Yellow : 10m Yellow : 20m
Red : 20m Black : 20m
Plug Red : 40m

MODEL 7238 1,570mm MODEL 8082 MODEL 8216 1,000mm


❋Simplified measurement ❋Extension probe ❋Temperature probe Applicable model
test leads Applicable model Applicable model
1011
4106 6020 2046R
6030 2056R

MODEL KTL04 950mm MODEL KAMP10 1,500mm


❋Test lead with IEC connector
AU UK Applicable model
Applicable model
6010A
1009 6010B
1011
TEST LEADS
6011A
1012

EU SA

AU : Australian plug
UK : British plug (13A)
EU : European SHUKO plug

Plug f4
SA : South african plug
Plug

77
INSTRUMENT GLOSSARY
INSTRUMENT GLOSSARY
Accuracy Diode Test

The accuracy of a digital tester is defined as the difference A function to apply a diode or a transistor a constant current
between the reading and the true value for a quantity having a value needed to turn it on in order to check the
measured in reference conditions. Accuracy is specified in the diode's or the transistor's forward voltage drop and identifying
format: (±xx% rdg ±xx dgt) the connection direction of the device.

The first portion identifies a percentage error relative to the


reading, which means it is proportional to the input. The Distortion Factor
second portion is an error, in digits, that is constant regardless
of the input. A degree of distortion of a waveform, typically expressed as
"Rdg"is for reading and "dgt"is for digits. Dgt indicates the the ratio of the effective value of harmonic components to the
counts on the last significant digit of the digital display and is effective value of the fundamental component.
typically used to represent an error factor of a digital tester.

Dual Integration Method


Auto-discharge Function
A technique to convert voltage into time. The first integration
A function used immediately after an insulation test to time (Ts) and the second integration time (Tx) are used. First,
automatically release charges stored within the circuit under the input voltage (Vx) is integrated on a certain time interval (Ts)
test during measurement. and then, the resulting voltage is "reverse-integrated" using a
Voltage remaining in the circuit under test can be monitored reference voltage (Vr) until it becomes 0 (zero).
during auto-discharging process as the scale reading.
The "reverse-integration time" (Tx) is proportional to input
voltage (Vx). Therefore, the input voltage (Vx) can be
Auto-ranging determined by measuring Tx.

A function of a tester to automatically select the appropriate With this technique, stable measurements can be taken with
measuring range based on the input signal. high accuracy, resolution and noise rejection ratio. One
particular advantage is high noise rejection ratio at 50 or 60Hz
power line frequency. All of Kyoritsu digital clamp meters and
Average Value testers utilize this method.

The average of an AC waveform's instantaneous values taken


over a half cycle. Ordinary testers respond to the average Effective Measuring Range of Insulation Tester
value.
The measuring range for which the accuracy of an insulation
For sinusoidal wave : tester is guaranteed. There are two kinds of effective
Average value = Maximum value×2/π= Maximum value×0.637 measuring ranges: the first and second effective measuring
ranges.
When the true RMS value is 100V ;
Average value= Maximum value×2/π=141×0.637 = 90(V) First effective measuring range
The reading of ordinary testers is calibrated in terms of the From 1/1000 to 1/2 the maximum effective scale value
effective value of a sinusoidal wave even though they are (When there is no major scale division for 1/2 the maximum
responding to the average value. They are called average- effective scale value, the nearest major scale division is used.)
responding-RMS-calibrated type of testers. As opposed to
these, true-RMS type testers respond and show the true RMS Second effective measuring range
value. Scales divisions not included in the first effective measuring range
For example for a 500V/100MΩ insulation tester;
First effective measuring range: 0.1-50MΩ(±5% of indicated
Crest Factor value)
Second effective measuring range: 50-100MΩ(±10% of
The ratio of the maximum value to the effective value. indicated value)
It represents the range of input in which a tester maintains
linear operation, expressed by a multiple of the full scale value
of the range being used. Form Factor
Crest factor = Maximum value/True RMS value
For sinusoidal wave; The ratio of the effective value to the average value.
Crest factor = 141/100 = 1.41 Form factor = Effective value/Average value

Data Hold Frequency Response

A function to freeze the reading on a digital display for ease of The manner in which a device changes its output quantity it,
checking or recording even in a difficult-to-read situation for a its indication for a measured quantity or its response over a
tester. range of frequencies.
AC signals to measure with a tester can be of one frequency
or from a wide frequency band ranging from low to high
Decibel: dB frequencies. To measure these frequencies, it is better to use
a tester having a wide frequency response range.
A unit used to express the magnitude of change in level of
electric signal or sound intensity.
A voltage ratio of 1 to 10 is equal to -20dB, 10 to 1 to 20dB, Hall Element
100 to 1 to 40dB and 1000 to 1 to 60dB. A power ratio of 10
to 1 is not 20dB, but 10dB, since power(P) is proportional to When a current-carrying conductor is placed in a magnetic
the square of voltage(V). field so that the direction of the magnetic field is perpendicular
78
INSTRUMENT GLOSSARY
to the direction of the current flow, voltage is developed in Sensitivity
the direction perpendicular to both the magnetic field and the
current flow. This is called the Hall effect and the Hall element The ability of a tester to respond to the quantity to measure,
is a device that utilizes the effect. expressed as the ratio of a change induced in the reading to a
Kyoritsu AC/DC clamp meters and clamp sensors employ the change in the input:
Hall element.
Change in reading
Sensitivity =
Change in quantity to measure
Harmonics

Power line AC voltage from a utility company has near Shock Hazard
sinusoidal waveform of fundamental frequency with little
distortion. When only a load consisting of resisters, capacitors Also referred to as electric shock. When a person touches a
and coils, called a linear load (its constant is fixed regardless motor that has a "leak", a path can be created from the motor
of the amount of current flowing through it), is connected frame to the hand, body and feet of the person to the floor he
to mains supply, no distortion is introduced into the load is standing on to allow a current to flow through it, sometimes
current waveform. However, when a non-linear load, such resulting in a fatal accident.
as a semiconductor and a saturable reactor, is connected, The seriousness of a shock hazard widely varies depending on
distortion appears in the load current waveform. The current the amount and duration of the current that flows through the
with a waveform containing distortion, or harmonic current, person' s body. His constitution, age and medical condition
flows in the direction toward the low impedance side and are also variation factors, but in general, at a frequency of 50
in the process, produces voltage drop over the impedance or 60Hz, stimulus to the skin is felt at 1mA, considerable pain
of the current path, causing the load voltage also to contain occurs at 5mA, pain is unbearable at 10mA, there is difficulty
harmonics. in releasing the "leaking" object because of intense muscle
contraction at 20mA, it is considerably dangerous at 50mA
and fatality is likely at 100mA. For the safety limit for a fatal
Indicated Value current, which causes ventricular fibrillation, Professor Dalziel
proposed the following equation from numbers of experiments
The value indicated by a tester for a measured quantity on animals.
I = 165 t
Where, I = current (mA) and t = time (sec).
Peak Hold From this theory, the maximum duration for a current of 165mA
is 1 second.
A function to memorize the peak value over a certain period of
time.
*Response time is selectable from approx. 10ms and 100ms. Thermocouple
Reading in the peak hold mode is the peak current value
multiplies by 1/ 2. A device that uses the voltage developed by the junction of
(When the input is sinusoidal, the reading is equal to the true two dissimilar metals to measure temperature. One junction,
RMS value.) called the measuring junction, is placed at the point where
temperature is to be measured. The other junction, called the
reference junction, is maintained at a reference temperature.
Peak Value The voltage developed between the two junctions varies
depending on the difference between the temperatures of the
The value at a point where a waveform has the maximum two junctions and the type of thermocouple.
amplitude.

True RMS Value


Resolution
The square root of the average of the square of a periodic
The minimum increments in which a tester can take waveform's instantaneous values taken over one cycle. It is
measurements. also called the rms value and the most closely relates to such
form of energy as force and heat.
(The effective value of an alternating current is expressed
Sample Rate as the value of the direct current which produces the same
amount of heat as the alternation current does.)
Frequency at which an A/D converter circuit senses the
quantity to measure: typically, twice or three times per second. For sinusoidal wave :
True RMS = Maximum value×1/ 2= Maximum value×0.707

When a True RMS is 100V ;


Maximum value = True RMS× 2= 100×1.41 = 141(V)

Measurement categories
To ensure safe operation of measuring instruments, IEC61010-1 establishes safety stan-
dards for various electrical environments, categorized as CAT.1 to CAT.4, and called mea-
surement categories.
(Over-voltage categories) Higher-numbered categories correspond to electrical environments with greater transient
energy (that can be very dangerous), so a measuring instrument designed for CAT.4 envi-
ronments can endure greater transient energy than one designed for CAT.3 or lower.

CAT.1 : Secondary electrical circuits connected to an outlet through a transformer or similar device.
Secondary electrical circuit parts inside equipments like TVs, PCs, Copiers, etc.
Interior wiring
CAT.2 : Primary electrical circuits or equipments connected to an outlet by a power cord. Outlets at
Incoming wire more than 10 meters from CAT.3source, or at more than 20 meters from CAT.4 source.

Transformer
CAT.3 : Primary electrical circuits of the equipment connected directly to the distribution panel.
Switchboards, busbars and feeders from the distribution panel to outlets.
Socket
CAT.4 : The circuit from the service drop to the service entrance, and to the power meter and primary
over current protection device (distribution panel). Circuits close to the secondary side of low
voltage power transformer.

79
QUALITY CONTROL CONCEPT
Kyoritsu Quality Control Concept
Kyoritsu started early an effort to establish system that en- based on the units established and maintained by National In-
sures traceability to the national standards in order to produce stitute of Advanced Industrial Science and Technology (AIST).
reliable instruments as well as instruments that can assure reli- The standard is used as the in-house standard to calibrate all
ability of other equipment and installations. the test and measuring equipments which are used in-house.

When traceability is in place, measurements taken with an in- Voltage : Fluke 5520A calibrators are used as in-house DC
strument any time and anywhere in any situation can be relat- and AC voltage standards.
ed to the appropriate national measurement standards through Current : DC or AC current is converted to a voltage by a
a clear and unbroken chain of comparisons. standard resistor, and the voltage is calibrated
with a precision digital multimeter.
For example, in terms on measurement defined by JIS (Japa- Resistance : Calibration resisters are calibrated with a DC
nese Industrial Standards), traceability is specified as a condi- standard current generator and the precision
tion in which a calibration path is established from instruments digital multimeter.
produced or in-house standards to higher level standards to
the national standards. Kyoritsu currently has a system in
place as shown in the figure below.

Our calibrator (standard) is calibrated at Japan Electric Meters


Inspection Corporation (JEMIC), Japan Quality Assurance
Organization (JQA) and Fluke Japan who perform calibration

Calibration System for Electrical Measuring Instruments

National Institute of Standards National Institute of Advanced Industrial Science


and Technology (NIST) and Technology (AIST)

Japan Electric Meters


Inspection Corporation (JEMIC)

Fluke Corporation
Agilent Technologies,Inc.

Precision multimeters

Standard resisters

AC standard voltage DC standard voltage


Calibration resisters
and current generator and current generator

Instruments used in design & development,


production, inspection and service departments.

CE Marking:signifies conformance to EMC directive


(89/336/EEC,92/31/EEC,93/68/EEC or 2004/108/EC)
and Low Voltage directive
(2006/95/EC)

80
PRODUCT INDEX
PRODUCT INDEX
1000 5000-02 5000+8142×2+8143 46
1009 Digital Multimeter 7 5001 Leak Logger (Long life type) 45
1011 Digital Multimeter 7 5001-01 5001+8141+8142+8143 46
1012 Digital Multimeter 7 5001-02 5001+8142×2+8143 46
1018 Digital Multimeter (Soft case type) 8 5010 AC Current Logger 47
1018H Digital Multimeter (Hard case type) 8 5020 AC Current/Voltage Logger 47
1030 Digital Multimeter (Pen type) 8 5201 Digital Illuminometer 65
1061 Digital Multimeter 9 5202 Digital Light Meter 65
1062 Digital Multimeter 9 5402D RCD Tester 43
1106 Analogue Multimeter 6 5406A RCD Tester 43
1109 Analogue Multimeter 6 5410 RCD Tester 44
1110 Analogue Multimeter 6 5500 Infrared Thermometer 66
1700 Voltage Tester 10 5510 Infrared Thermometer 66
1710 Voltage Tester 10
6000
2000 6010A Multi Function Tester 50
2000 Digital Multimeter 11 6010B Multi Function Tester 51
2001 Digital Multimeter 11 6011A Multi Function Tester 52
2002PA Digital Clamp Meter 13 6016 Multi Function Tester 53
2002R Digital Clamp Meter 13 6017 Multi Function Tester 55
2003A Digital Clamp Meter 16 6018 Multi Function Tester 55
2004 Digital Clamp Meter 16 6020 Multi Function Tester 56
2006 Digital Clamp Meter 13 6030 Multi Function Tester 56
2007A Digital Clamp Meter 13 6050 Multi Function Tester 57
2009A Digital Clamp Meter 16 6200 Portable Appliance Tester 58
2010 Digital Clamp Meter 17 6201A Portable Appliance Tester 58
2017 Digital Clamp Meter 14 6202 Portable Appliance Tester 58
2027 Digital Clamp Meter 14 6300 Power Meter 59
2031 Digital Clamp Meter 14 6300-00 6300 60
2033 Digital Clamp Meter 17 6300-01 6300+8125×3 60
2037 Digital Clamp Meter 17 6300-02 6300+8125×2 60
2040 Digital Clamp Meter 15 6300-03 6300+8124×3 60
2046R Digital Clamp Meter 18 6300-04 6300+8124×2 60
2055 Digital Clamp Meter 18 6300-05 6300+8126×3 60
2056R Digital Clamp Meter 18 6300-06 6300+8126×2 60
2300R Fork Current Tester 11 6300-07 6300+8127×3 60
2412 Leakage Clamp Meter 19 6300-08 6300+8127×2 60
2413F Leakage Clamp Meter 19 6300-09 6300+8128×3 60
2413R Leakage Clamp Meter 19 6300-10 6300+8128×2 60
2417 Leakage Clamp Meter 20,56 6310 Power Quality Analyzer 61
2431 Leakage Clamp Meter 20 6310-00 6310 64
2432 Leakage Clamp Meter 20 6310-01 6310+8125×3 64
2433 Leakage Clamp Meter 21 6310-02 6310+8125×2 64
2433R Leakage Clamp Meter 21 6310-03 6310+8124×3 64
2434 Leakage Clamp Meter 21 6310-04 6310+8124×2 64
2608A Analogue Clamp Meter 12 6310-05 6310+8126×3 64
2805 Analogue Clamp Meter 12 6310-06 6310+8126×2 64
6310-07 6310+8127×3 64
3000 6310-08 6310+8127×2 64
3001B Digital Insulation/Continuity Tester 26 6310-09 6310+8128×3 64
3005A Digital Insulation/Continuity Tester 26 6310-10 6310+8128×2 64
3007A Digital Insulation/Continuity Tester 26 6310-11 6310+8129-03×1 64
3021 Digital Insulation/Continuity Tester 27 6310-12 6310+8129-02×1 64
3022 Digital Insulation/Continuity Tester 27
3023 Digital Insulation/Continuity Tester 27 7000
3111V Analogue Insulation/Continuity Tester 28 7014 Output cord 13,16,17,19,73
3131A Analogue Insulation/Continuity Tester 28 7019 Test leads 43,73
3132A Analogue Insulation/Continuity Tester 29 7025 Test leads 26,28,30,31,50,51,73
3144A Analogue Insulation/Continuity Tester 29 7058 Test leads 33,73
3145A Analogue Insulation/Continuity Tester 29 7060 Temperature probe 6,12,73
3146A Analogue Insulation/Continuity Tester 29 7061 Output cord 25,73
3161A Analogue Insulation/Continuity Tester 29 7066 Test leads 6,12~19,73
3165 Analogue Insulation Tester 30 7067 Test leads 12,13
3166 Analogue Insulation Tester 30 7073 2WAY Output cord 19,73
3315 Analogue Insulation Tester 30 7081 Guard cord 30,31,73
3316 Analogue Insulation Tester 30 7082 Leads for recorder 33,73
3321A Analogue Insulation Tester 31 7083 Leads for battery charging 33,73
3322A Analogue Insulation Tester 31 7084 Earth and guard leads 33,73
3323A Analogue Insulation Tester 31 7085 Test leads 6,73
3121 High Voltage Insulation Tester 33 7088 Test leads for phase indicator 56,73
3122 High Voltage Insulation Tester 33 7089 Test leads 56,74
3123 High Voltage Insulation Tester 33 7090 Test leads 56,74
3124 High Voltage Insulation Tester 33 7091 Test leads for earth resistance 56,74
3125 High Voltage Insulation Tester 34 7092 Cord reel 56
3128 High Voltage Insulation Tester 35 7093 Cord for extension probe 56,74
7095 Test leads for earth resistance 37,38,55,74
4000 7100 Precision measurement cord set 37,38,55,74
4102A Earth Tester (Soft case model) 37 7103 Test leads with remote control switch 55,74
4102A-H Earth Tester (Hard case model) 37 7107 Test leads 13,16,74
4105A Earth Tester (Soft case model) 38 7115 Extension probe 27,30,31,74
4105A-H Earth Tester (Hard case model) 38 7116 Extension probe 29,31,74
4106 Earth Tester 39 7121A Distribution board test leads 41~43,57,74
4200 Earth Clamp Tester 40 7122A Test leads 26,28,29,31,52,74
4116A LOOP/PSC Tester 41 7123 Molded plug test lead [AU] 41,43,58,74
4118A LOOP/PSC Tester 41 7124 Molded plug test lead [UK] 41,43,74
4120A LOOP/PSC Tester 42 7125 Molded plug test lead [EU] 41,43,57,58,74
7126 Molded plug test lead [SA] 41,43,74
5000 7127 Simplified measurement test leads 37,38,75
5000 Leak Logger (standard type) 45 7128 Test leads 44,75
5000-01 5000+8141+8142+8143 46 7129 Test lead with alligator clip 44,58,75

81
PRODUCT INDEX

7000 8216 Temperature probe 7,18,77


7131 Safety crocodile clip [black] 55 8241 USB Communication set 9
7132A(KSLP5) External earth probe 52,75 8243 Printer Communication set 9
7133A(OMA DIEC) Distribution board test leads 50~52,75 8246 Printer 9
7139 Test leads with remote control switch 74 8247 Thermal paper for printer 9
7140 Adaptor for extension cord 58 8248 AC adapter for printer [EU] 9
7141 Voltage test lead set 60,61,75 8249 DMM printer full set 9
7146 Banana φ4 adjuster plug 69,70,71,75 8302 Adaptor for recorder 34
7148 USB cable 46,48,60,61 8304 Resister for operation check 40
7149 Test leads with remote control switch set 29,31,75 8307 Compact flash card [128MB] 60,61
7150 Test leads with remote control switch set 27,30,31,75 8309 Voltage sensor 48,49,71,72
7153A Safety test leads 75 8312 Power supply adaptor 60,61,64,72
7154A Safety test leads 75 8319 CF card reader 60,61
7155A Safety test leads with fuse 75 8320 AC adaptor 48,49,72
7156A Safety test leads with fuse 75 8322 Compact flash card [256MB] 61
7157A Safety crocodile clips 75 8323 Compact flash card [1GB] 61
7158A Safety crocodile clip for fuse 75 8325F Flicker sensor 61,64,71,72
7159A Safety test leads with fuse 76 8405 Temperature probe 9
7161 Flat test bar [black] 55,58 8406 Temperature probe 9
7165 Line probe 34,76 8407 Temperature probe 9
7166 Earth cord 34,76 8408 Temperature probe 9
7167 Guard cord 34,76 8901 Fuse [0.5A/250V] 6,12
7168 Line probe with alligator clip 34,76 8902 Fuse [1A/250V] 28
7170 Power cord 35,60,61,76 8918 Ceramic fuse [0.8A/600V] 7
7185 Extension cable 46,48,69~71,76 8919 Ceramic fuse [10A/600V] 7
7187 Power cord [UK] 76 8923 Fuse [F500mA/600V] 6,26,28,29
7188 Distribution board fused test lead set 53,76 8924 Fuse [0.5A/250V] 7
7196 Test leads with remote control switch 53,76 8925 Fuse [10A/250V] 7
7197 Small clips adaptor 48,49,71,72,76 8926 Fuse [440mA/1000V] 9
7198 Small clips adaptor 60,61,64,72,76 8927 Fuse [10A/1000V] 9
7199 Output cable 69,76
7218 Power cord [EU] 53,76 9000
7220 Test leads 9 9022 Carrying case 24
7221 Power cord [SA] 76 9029 Carrying case 67
7222 Power cord [AU] 76 9038 Carrying case 28
7224 Earth cord 35,76 9039 Carrying case[Hard] 33
7225 Guard cord 35,77 9041 Cord case 29,31
7226 Line probe 35,77 9045 Cord case 43
7227 Line probe with alligator clip 35,77 9050 Carrying case 26
7228 Earth cords 53,77 9055 Carrying case 16,25
7229 Precision measurement test leads 39,77 9056 Carrying case 24
7238 Simplified measurement test leads 39 9057 Carrying case 25
9059 Carrying case 6
8000 9066 Carrying case 13
8004 Multi-Tran 12~21,24 9070 Carrying case 67
8006 AC Clamp Adaptor 24 9071 Carrying case 17
8008 Multi-Tran 12~21,24 9072 Carrying case 19
8016 Pickel type prod 27,29,30,31,55 9074 Cord case 26,28,29,30
8017 Extension prod 44,55 9076 Carrying case 6,14,17,20
8019 Pickel type prod 33~35 9079 Carrying case 14,17,20
8020 Adaptor for recorder 33 9080 Carrying case [Aluminium] 56
8022 AC adaptor [110V] 17,19 9081 Carrying case 56
8023 AC adaptor [220V] 17,19 9084 Soft case 37,38
8025 Output plug 19 9089 Carrying case 27,30,31
8029 Extension prod 35 9090 Carrying case 14,17,20
8030 Phase indicator 67 9091 Carrying case for cord reels 55
8031 Phase indicator 67 9092 Cord case 50,51,52,55
8031F Phase indicator 67 9094 Carrying case 13,15,16,18,19,67,69,70,71
8032 Auxiliary earth spikes 37~39,53,55 9095 Carrying case 69,70,71
8079 Battery charger [120V] 33 9097 Carrying case 12,13,20,21
8080 Battery charger [220V] 33 9103 Carrying case 6
8082 Extension probe 56,77 9106 Hard case 37,38
8083 Auxiliary earth spikes 56 9107 Soft case 11
8112 AC Clamp Adaptor 25 9112 Carrying case [Hard] 33
8112BNC AC Clamp Adaptor 25 9113 Carrying case 11
8113 AC/DC Clamp Adaptor 25 9114 Carrying case [Hard] 8
8121 Load current Clamp Sensor 48,49,70,72 9115 Carrying case [Soft] 8
8122 Load current Clamp Sensor 48,49,70,72 9118 Carrying case [Soft] 46,48
8123 Load current Clamp Sensor 48,49,70,72 9119 Carrying case [Hard] 46,48,49,72
8124 Load current Clamp Sensor 60,61,64,69,72 9120 Cord case 27,31
8125 Load current Clamp Sensor 60,61,64,69,72 9121 Shoulder strap 26~31,37,38,41~44,52,53,55,57,58
8126 Load current Clamp Sensor 60,61,64,69,72 9123 Shoulder strap 29,30
8127 Load current Clamp Sensor 60,61,64,69,72 9124 Carrying case [Hard] 34
8128 Load current Clamp Sensor 60,61,64,69,72 9125 Carrying case 39,60,61
8129 Flexible Clamp Sensor 48,49,60,61,64,69,72 9128 Carrying case [Hard] 40
8141 Leakage current Clamp Sensor 46,49,61,64,71,72 9130 Carrying case 8
8142 Leakage current Clamp Sensor 46,49,61,64,71,72 9132 Carrying case with magnet 60,61,64,72
8143 Leakage current Clamp Sensor 46,49,61,64,71,72 9135 Carrying case 46,48,49,72
8146 Leakage & Load current Clamp Sensor 48,49,61,64,70,72 9137 Carrying case 69
8147 Leakage & Load current Clamp Sensor 48,49,61,64,70,72 9142 Carrying case 53
8148 Leakage & Load current Clamp Sensor 48,49,61,64,70,72 9144 Carrying case 12
8200-03 Cord reel [3pcs] 55 9147 Cord case 41,42~44,57,58
8200-04 Cord reel [4pcs] 39,41~43,57,74 9148 Shoulder strap 50,51
8201 Output plug 13,16 9149 Shoulder strap 56
8205A Demonstration Panel 68 9150 Carrying case 9
8208 Demonstration Panel 68 KAMP10 Test lead with IEC connector 50~52,77
8212-RS232C RS232C adaptor with “KEW Report(Software)” 39,51,53,57 KTL04 Test leads 7,77
8212-USB USB adaptor with “KEW Report(Software)” 39,51,53,57 Ni-Cd rechargeable battery 33
8212-USB-W USB adaptor with “KEW Windows(Software)” 35
8215 Demonstration Panel 68

82
KYORITSU GLOBAL NETWORK

Test and Measuring Instruments Catalogue 2009

Catalogue 2009
Japan

Italy
U.K.
U.S.A.
China

Thailand

Headquarters
Affiliates

● KYORITSU ELECTRICAL ● Kew (Thailand) Ltd. ● Kewtech Corporation Ltd.


INSTRUMENTS WORKS, LTD. Navanakorn Industrial Estate60/48, Moo 19, Midas House, Unit 2b Stones Courtyard,
No.5-20, Nakane 2-chome, Klongluang,Pathumthani, 12120 Thailand High Street, Chesham, Buckinghamshire,
Meguro-ku, Tokyo, 152-0031 Japan Phone: 66-2-529-0542~4 HP5 1DE, England
Phone: 81-3-3723-0131 FAX: 66-2-529-0541 Phone: 44-1494-792212
FAX: 81-3-3723-0152 FAX: 44-1494-791826
URL:http://www.kew-ltd.co.jp
E-mail: info@kew-ltd.co.jp
Factory: Ehime

● Kew Europe Office ● Kyoritsu America, LLC ● KYORITSU SHANGHAI


Viale Rimembranze 93/18, 4175 Veterans Memorial Highway, TRADING COMPANY LIMITED
20099 Sesto S. Giovanni (MI) Italy Suite 400, Ronkonkoma, NY, 11779, U.S.A. Room241, 2nd Floor, No.12 Waitan Building,
Phone: 39- 02- 38238685 Phone: 1-631-676-7566 No.12 Zhongshan Dong Yi Road,
FAX: 1-631-676-7563 Huangpu District, Shanghai P.C.200002 China
Phone: 86-21-6321-8899
FAX: 86-21-6339-2868

Please read the "Safety Warnings" in the instruction manual supplied with the instrument thoroughly and completely
Safety Warnings : for correct use. Failure to follow the safety rules can cause fire, trouble, electrical shock, etc. Therefore, make sure
to operate the instrument on a correct power supply and voltage rating marked on each instrument.

For inquires or orders :

In consideration of the environment, soy ink and recycled paper were used in this publication. The contents of this leaflet are subject to change without notice. GeneCata09-1E Sep. 08 AD

Das könnte Ihnen auch gefallen