Sie sind auf Seite 1von 5

TX output power & Combiner loss (dBm)

Low –loss configuration (Non Combine)

Combine Configuration
Standard MP Configuration

MP Power 45.44dBm / 35W ====>   ANCD Non-Combine (-0.95dBm) ===> 44.4dBm / 27.5W  

MP Power 45.44dBm / 35W ====>   ANCD Combine (-4.4dBm) ===> 41.0dBm / 12.5W  

MP Power 45.44dBm / 35W ====>   ANY (-3.3dBm) ANCD Combine (-4.4dBm) ===> 37.5dBm / 5.6W

No-Double Ant Solution


No.MP TRX No. of Output power at Ant
per sector Antenna ANCD mode ANY Mode TRE Type Connector Remark
1 TRE 1 No-Combining (-0.95dBm) - MP Low-loss 44.4dBm / 27.5W Used
2 TRE 1 No-Combining (-0.95dBm) - MP Low-loss 44.4dBm / 27.5W Used
3 TRE 1 Combining (-4.4dBm) - MP Combine 41.0dBm / 12.5W Used
4 TRE 1 Combining (-4.4dBm) - MP Combine 41.0dBm / 12.5W Used
5 TRE 1 Combining (-4.4dBm) Combine (-3.3dBm) MP Combine + ANY 37.5dBm / 5.6W Used less
6 TRE 1 Combining (-4.4dBm) Combine (-3.3dBm) MP Combine + ANY 37.5dBm / 5.6W Used less
7 TRE 1 Combining (-4.4dBm) Combine (-3.3dBm) MP Combine + ANY 37.5dBm / 5.6W Used less
8 TRE 1 Combining (-4.4dBm) Combine (-3.3dBm) MP Combine + ANY 37.5dBm / 5.6W Used less
* Remark; used / used less: configuration on north region network

MP Low -loss Configuration

Double Ant Solution


No.MP TRX No. of Output power at Ant
per sector Antenna ANCD mode ANY Mode TRE Type Connector Remark
1 TRE 1 No-Combining (-0.95dBm) - MP Low-loss 44.4dBm / 27.5W Used
2 TRE 1 No-Combining (-0.95dBm) - MP Low-loss 44.4dBm / 27.5W Used
3 TRE 2 No-Combining (-0.95dBm) - MP Low-loss (Double Ant) 44.4dBm / 27.5W Not Used
4 TRE 2 No-Combining (-0.95dBm) - MP Low-loss (Double Ant) 44.4dBm / 27.5W Not Used
5 TRE 2 Combining (-4.4dBm) - MP Combine (Double Ant) 41.0dBm / 12.5W Used
6 TRE 2 Combining (-4.4dBm) - MP Combine (Double Ant) 41.0dBm / 12.5W Used
7 TRE 2 Combining (-4.4dBm) - MP Combine (Double Ant) 41.0dBm / 12.5W Used
8 TRE 2 Combining (-4.4dBm) - MP Combine (Double Ant) 41.0dBm / 12.5W Used
Standard HP configuration

HP Power 47.78dBm / 60W ====> ANCD Non-Combine (-0.95dBm) ===> 46.54dBm / 47.8W

HP Power 47.78dBm / 60W ====> ANCD Combine (-4.4dBm) ===> 42.8dBm / 24W

No Double Ant solution


No. HP TRX No.of Output power at Ant
per sector Antenna ANCD mode ANY Mode TRE Type Connector Remark
1 TRE 1 No-Combining (-0.95dBm) - HP Low-loss 46.54dBm / 45W Used
2 TRE 1 No-Combining (-0.95dBm) - HP Low-loss 46.54dBm / 45W Used
3 TRE 1 Combining (-4.4dBm) - HP Combine 42.73dBm / 18.7W Used
4 TRE 1 Combining (-4.4dBm) - HP Combine 42.73dBm / 18.7W Used

HP Low –loss configuration

Double Ant solution


No. HP TRX No.of Output power at Ant
per sector Antenna ANCD mode ANY Mode TRE Type Connector Remark
1 TRE 1 No-Combining (-0.95dBm) - HP Low-loss 46.54dBm / 45W Used
2 TRE 1 No-Combining (-0.95dBm) - HP Low-loss 46.54dBm / 45W Used
3 TRE 2 No-Combining (-0.95dBm) - HP Low-loss (Double Ant) 46.54dBm / 45W Used
4 TRE 2 No-Combining (-0.95dBm) - HP Low-loss (Double Ant) 46.54dBm / 45W Used
5 TRE 2 Combining (-4.4dBm) - HP Combine (Double Ant) 42.73dBm / 18.7W Not Used (Heat Over)
6 TRE 2 Combining (-4.4dBm) - HP Combine (Double Ant) 42.73dBm / 18.7W Not Used (Heat Over)
7 TRE 2 Combining (-4.4dBm) - HP Combine (Double Ant) 42.73dBm / 18.7W Not Used (Heat Over)
8 TRE 2 Combining (-4.4dBm) - HP Combine (Double Ant) 42.73dBm / 18.7W Not Used (Heat Over)

Das könnte Ihnen auch gefallen