Crompton Greaves Metric Frame Industrial Motors

From 0.18kW to 25OkW, 2 Poles, 4 Poles, Features

6 Poles and 8 Poles TEFC, DP, Flame-proof Cast Aluminium and Cast Iron Frames for
(Type 'd'), Increased Safety (Type 'e'), sturdy construction.

Non-Sparking (Type 'n'), Pressurised S1 to S8 Duty Cycles for all applications.

(Type 'p'), Squirrel Cage Rotor and Slip-ring Special designs for Crane Duty, Machine Tool

Motors, in cast aluminium or cast iron Duty, Textile Duty, Rolling Mill Duty etc.

Frames 56 to 355L for 11OV to 66OV, Standards/Approvals

50/60Hz supply. Conforms to IEC 335 for Performance.


Flameproof motors have BASEEFA
Option of variety of mountings, shaft (British Approvals Service for Electrical
extensions, thermisters, Space Heaters, Equipment in Flammable Atmospheres)
Anti-Corrosive treatment, sealed bearings Certification in Frames E100L to E200L

etc. Carry CE Mark for Europe.

2
INDEX

CONTENTS PAGE NO.

PRINCIPLES OF INDUCTION MOTORS .............................................................2

TEFC, SQUIRREL CAGE MOTORS .............................................................4

TEFC, SLIPRING MOTORS ............................................................28

DRIP PROOF, SQUIRREL CAGE MOTORS ...........................................................38

DRIP PROOF, SLIPRING MOTORS ............................................................45

SELECTION OF MOTORS ............................................................50

1 Next Page

1
PRINCIPLES OF
INDUCTION MOTOR

PRINCIPLES OF INDUCTION MOTOR

MOVEMENT LOAD

CURRENT INDUCED
FLOW EQUIVALENT
MAGNET
N
N A current flowing in a
conductor produces a
magnetic field

S S

The direction of
If a magnetic field is cut by a moving current flow
S conductor, an EMF (voltage) is induced in the N determines the
conductor. When external circuit is completed polarity of the
a current flows through the conductor. induced magnetic
field.

MAGNETS
N S N MOVEMENT

CONDUCTOR

FORCE OR PULL

MOVEMENT

S N S
MAGNETS
The magnetic field as it moves to the right, relative to the conductor, induces a current in the conductor. This induced
current produces an induced magnetic field which opposes this relative movement (Lenz's Law). As long as the relative
movement continues a force is produced which will tend to move the conductor to the right (i.e. tending to lift the load).

ROTATING MAGNETIC FIELD

TIME 1 2 3 4 5 6 7 TIME 1
A
N TIME 2 A S TIME 3 A S TIME 4
A
PHASE A
CURRENT
N C B C B C
C B
N
S

N
S

Three Phase A S TIME 2 A N TIME 3 A N TIME 4


Alternating PHASE C
Current CURRENT
C B
C B C B C B
S

S
N

N
S

PHASE B
CURRENT
At time 1 the upper At time 2, poles At time 3, poles (A)
Alternating current can be used pole (A) is at a (A) and (B) have and (C) have S
to produce a moving magnetic maximum N N polarity. (A) is polarity. Pole (B)
polarity. The lower decreasing and has increased to
field. 3 phase a.c. applied to field
poles have S (B) is increasing. maximum N
coils as shown, produces a polarity: (B) is Pole (C) now has polarity.The pattern
rotating magnetic field. decreasing and (C) maximum S continues to Time 7
is increasing (S polarity. then begins the
polarity). cycle again.

2 2
PRINCIPLES OF
INDUCTION MOTOR

STATOR AND ROTOR

ROTATING MAGNETIC
C TIONOF FIEL
DIRE D

ROTOR WITH
CONDUCTORS N S

STATOR
FIELD
COILS

S N

ROTOR WITH DIRECTION OF TORQUE


CONDUCTORS
STATOR FIELD
COILS
The squirrel cage rotor consists of a cylindrical core The induction motor consists of two parts; a stator
into which bar conductors are slotted. These are all with field coils remaining stationary on the outside,
joined at their ends to end rings forming a conducting and a rotor which rotates in the centre producing the
cage. drive. The alternating current in the stator field coils
produces a rotating magnetic field. This field moving
relative to the rotor cuts the conductors in the rotor
thus inducing a current. The induced current produces
an induced magnetic field which opposes the relative
movement. This gives rise to a force (torque) on the
conductors causing the rotor to rotate in the direction
of the magnetic field movement.

The A.C. Induction Motor. Three Phase Speeds


Typical full load speeds on 50 cycle supply
The rotating magnetic field produced by the stator cuts
No. of poles 2 4 6 8 10
the rotor bars, producing induced voltages and
Syn. speed RPM currents. These currents produce a torque in the same
3000 1500 1000 750 600
(Magnetic field speed) direction as the rotating field. In order to produce
Full load speed RPM driving troque, the magnetic field must cut the rotor
2900 1440 960 720 580
(Rotor speed) bars, hence the rotor always rotates at a lower speed
than the rotating field.
3-Phase connection and Starting
The induced current in the rotor will be maximum at
starting when the relative movement between rotor and
rotating field is greatest. To prevent damage from this
high current, the voltage across each stator phase is
reduced to 1/ √ 3 of line voltage by means of a star
STAR DELTA
(STARTING) (RUNNING) delta connection. When the motor has attained full
speed, full voltage is applied to each phase by
switching from star to delta.

3 3
TEFC
SQUIRREL CAGE
MOTORS

APPLICATION Motors in frames above 280M have rotor bars


of copper or copper alloy, brazed to copper or
Being totally enclosed, these motors are copper alloy end-rings. The shaft is of high
suitable for almost all applications and in grade rolled steel, with drilled and tapped hole
particular for locations where dust, excessive provided at driving end as standard practice.
moisture, metal chips or other harmful
substances make the use of an open motor Rotors are dynamically balanced to comply
undesirable. with the "Normal" requirements of BS 4999.
"Precision Class" can be offered, if required.
Dimensions and performance are in accordance
with IEC and other international standards. BEARINGS
ENCLOSURE Motors upto 225M frame are provided with
anti-friction double neoprene sealed "greased-
All our motors have inherent IP55 degree of for-life" deep groove shielded ball bearings
protection. and higher frames are provided with ball/roller
INSULATION bearings. The life of the bearings is minimum
20,000 hours.
All motors are manufactured with Class F On-line greasing arrangement is provided for
insulation system, but with temperature rise
frames ND250 and above.
restricted to Class 'B' limits except for specific
ratings which are duly marked. CONNECTIONS
CONSTRUCTION All motors are provided with a stud type
terminal block.
Stator body and endshields from Frame 132
upwards are of high grade cast iron. These Motors upto 2.2 kW are provided with three
are machined to close tolerances for providing terminals for DOL starting and motors above
perfect alignment and fits. They are rigid in 2.2 kW, are provided with six terminals for
construction. Frames 63, 71, 80, 90, 100L and Star-Delta starting.
112M are of high grade diecast aluminium. An additional earthing terminal is provided
Shortly Motors in frames 132 as well, will be inside the terminal box.
available in diecast aluminium. ACCESSORIES
Terminal boxes of frames upto 132M are of
diecast aluminium. An O-ring is provided Thermistors and/or space heaters (optional)
between the terminal box and cover and a can be provided for all frames on request.
gasket between stator and terminal box. HARDWARE
Terminal boxes for frames 160 and above are of
cast iron and have flanged joints with suitable All hardware have metric threads and are zinc
gaskets between them. Terminal boxes are passivated for corrosion resistance.
provided with conduit entries having metric
threading, and where required with special Pg TESTS
threading suitable for German Pg glands. All Crompton Greaves TEFC SCR induction
Polypropylene fans are provided for frames upto motors are tested in the course of
180L and Cast iron/Aluminium fans for all higher manufacture in accordance with IEC and other
frames. The fans are suitable for both directions international standard testing procedures.
of rotation except 280/315 frame, 2 pole motors.
SPARES
The fan covers are of steel.
All motors are built to standardised designs
All motors have drain holes at their lowest position.
and all spare parts are interchangeable.
Standard Cast Iron Frame Motors are supplied
with Terminal Box at left hand side looking SPECIAL FEATURES
from non-driving end. Terminal Box at top can
Special features such as special shaft, dual
be supplied on request, for Cast Iron Frame
voltage capability, anticorrosive protection,
132, while all aluminium frames have Terminal
high ambient running, class H insulation,
Box on the top as standard.
different duty rating, etc can be provided to
CORE meet specific requirements. All details are
available on request. Additionally, special
Both stator and rotor cores consist of high frame sizes to suit South African and
quality magnetic steel. Australian requirements are also available.
ROTOR Pad Mouting feature is provided as required
for Air Stream Rated Motors for frames 80 to
All rotors upto 280M are pressure diecast. 132.

4 4
TEFC
SQUIRREL CAGE
MOTORS

PERFORMANCE DATA
Supply : 415 V or 380V, 50 Hz, 3 Phase AC Voltage Variation : ± 10%
Enclosure : Totally Enclosed Fan Cooled (TEFC) Frequency Variation : ± 5%
Degree of Protection : IP55 Combined Variation : ± 10%
Rating: Continuous, Duty : S1 Ambient : 45°C
Insulation Class : ‘F’ Temperature Rise by Resistance Method : 75°C Max.

P
OUTPUT FL FL EFFICIENCY (%) POWER FACTOR DOL STG. S/D STG. NETT
O FL GD²
FRAME AMPS AMPS WEIGHT
L RPM 3/4 1/2 3/4 1/2 STG. C STG. T STG. C STG. T KgM²
kW HP 380 V 415 V FL FL Kg.
E FL FL FL FL %FLC %FLT % FLC % FLT
0.18 0.25 2 AD63 2700 0.55 0.50 64.0 60.0 48.0 0.79 0.72 0.64 500 275 0.001 5.6
0.18 0.25 4 AD63 1330 0.85 0.75 50.0 46.0 40.0 0.65 0.58 0.47 400 200 0.003 5.6
0.25 0.33 2 AD63 2700 0.75 0.75 64.0 60.0 48.0 0.79 0.72 0.64 500 275 0.001 5.6
0.25 0.33 4 AD71 1350 1.10 0.90 58.0 53.0 48.0 0.60 0.55 0.49 500 200 0.004 7.0
0.37 0.50 2 AD71 2800 1.1 1.0 65.0 60.0 48.0 0.79 0.72 0.64 500 275 0.002 7.0
0.37 0.50 4 AD71 1350 1.4 1.2 65.0 58.0 45.0 0.64 0.58 0.48 500 200 0.004 7.0
0.37 0.50 6 AD80 910 1.3 1.1 64.0 58.0 50.0 0.69 0.60 0.50 400 200 0.011 10
0.37 0.50 8 AD90S 680 1.6 1.5 60.0 54.0 48.0 0.57 0.50 0.40 400 170 0.016 22
0.55 0.75 2 AD71 2800 1.6 1.5 68.0 64.0 57.0 0.79 0.72 0.61 600 300 0.003 10
0.55 0.75 4 AD80 1395 1.7 1.5 72.0 67.0 59.0 0.70 0.64 0.58 500 200 0.007 10
0.55 0.75 6 AD80 910 1.8 1.7 65.0 60.0 52.0 0.71 0.63 0.52 400 200 0.011 10
0.55 0.75 8 AD90L 680 2.1 1.9 62.0 56.0 46.0 0.63 0.54 0.45 400 170 0.021 25
0.75 1.0 2 AD80 2820 1.9 2.0 75.0 69.0 62.0 0.81 0.73 0.62 600 300 0.003 10
0.75 1.0 4 AD80 1400 2.2 2.1 74.0 69.0 61.0 0.70 0.65 0.60 500 200 0.007 10
0.75 1.0 6 AD90S 925 2.4 2.2 69.0 66.0 60.0 0.70 0.63 0.55 500 200 0.015 13
0.75 1.0 8 AD100L 690 2.8 2.8 65.0 56.0 46.0 0.63 0.54 0.45 400 175 0.030 19
1.10 1.5 2 AD80 *** 2820 2.8 2.5 75.0 72.0 64.0 0.81 0.76 0.68 600 275 0.006 10
1.10 1.5 2 AD90S 2830 2.6 2.3 77.0 72.0 64.0 0.82 0.76 0.68 600 275 0.006 13
1.10 1.5 4 AD90S 1410 2.8 2.7 77.0 71.0 63.0 0.77 0.70 0.62 500 200 0.014 13
1.10 1.5 6 AD90L 925 3.4 3.2 70.0 67.0 62.0 0.71 0.65 0.55 500 200 0.021 16
1.10 1.5 8 ND100LX 690 3.5 3.6 71.0 66.0 58.0 0.68 0.57 0.44 400 175 0.034 35
1.50 2.0 2 AD90S 2830 3.6 3.2 78.0 73.0 64.0 0.82 0.76 0.68 600 275 0.006 13
1.50 2.0 4 AD90L 1405 3.7 3.4 77.0 72.0 65.0 0.79 0.72 0.62 500 200 0.019 16
1.50 2.0 6 AD100L 925 4.1 4.0 75.0 71.0 64.0 0.75 0.68 0.58 500 200 0.030 19
1.50 2.0 8 ND112MX 700 4.7 4.3 72.0 67.0 60.0 0.68 0.58 0.46 400 190 0.057 45
2.20 3.0 2 AD90L 2830 5.2 4.8 79.0 73.0 66.0 0.82 0.77 0.70 600 275 0.008 16
2.20 3.0 4 AD100L 1425 5.1 4.8 80.0 75.0 69.0 0.82 0.76 0.68 600 200 0.030 19
2.20 3.0 6 ND112M 920 5.8 5.5 77.0 74.0 67.0 0.75 0.70 0.60 500 200 0.048 42
2.20 3.0 8 ND132S 710 6.0 5.7 76.0 71.0 64.0 0.73 0.68 0.61 450 180 0.174 68
3.0 4.0 2 AD100L 2865 6.5 7.3 82.0 79.0 73.0 0.85 0.80 0.72 700 250 0.022 19
3.0 4.0 4 ND100LX*** 1425 6.9 6.3 81.0 80.0 78.0 0.82 0.76 0.68 600 200 0.034 35
3.0 4.0 6 ND132S 940 7.0 6.5 82.0 79.0 74.0 0.79 0.75 0.68 500 200 0.174 68
3.0 4.0 8 ND132M 700 8.3 7.6 78.0 73.0 66.0 0.70 0.66 0.60 500 170 0.214 79
4.0 5.5 2 ND112M 2865 8.5 7.5 81.0 79.0 76.0 0.88 0.84 0.75 650 250 165 62 0.030 42
4.0 5.5 4 ND112MX*** 1430 9.0 8.5 82.0 81.0 78.0 0.81 0.76 0.69 600 200 150 50 0.052 45
4.0 5.5 6 ND132M 945 9.3 8.5 83.0 81.0 77.0 0.79 0.75 0.68 550 200 140 50 0.214 79
4.0 5.5 8 ND160M 710 10.0 9.0 85.0 85.0 83.0 0.74 0.70 0.62 500 200 140 60 0.460 121
5.5 7.5 2 ND132S 2865 11.5 10.5 84.0 82.0 79.0 0.89 0.84 0.76 700 250 175 62 0.062 68
5.5 7.5 2 ND112MX*** 2860 12.0 11.0 83.0 81.0 78.0 0.87 0.83 0.76 650 250 165 62 0.034 45
5.5 7.5 4 ND132S 1440 12.0 11.0 85.0 83.0 80.0 0.84 0.79 0.73 600 200 150 50 0.131 68
5.5 7.5 6 ND132M**** 945 13.1 12.0 83.0 81.0 77.0 0.80 0.75 0.68 550 200 140 50 0.214 79
5.5 7.5 8 ND160M 710 13.0 12.0 85.0 85.0 83.0 0.74 0.70 0.62 500 200 140 60 0.460 121
7.5 10.0 2 ND132S 2865 15.2 14.0 85.0 84.0 82.0 0.89 0.85 0.76 650 275 165 68 0.062 68
7.5 10.0 4 ND132M 1440 15.8 14.5 86.0 85.0 84.0 0.85 0.81 0.75 600 200 150 50 0.161 79
7.5 10.0 6 ND160M 970 16.0 15..0 87.0 87.0 86.0 0.80 0.76 0.68 550 225 155 65 0.460 121
7.5 10.0 8 ND160L 710 18.0 16..0 85.0 85.0 83.0 0.76 0.72 0.64 500 200 140 60 0.640 143
9.3 12.5 2 ND132M*** 2880 18.5 17.0 86.0 85.0 84.0 0.89 0.85 0.78 700 240 180 60 0.076 79
9.3 12.5 2 ND160M 2920 18.0 16.5 87.0 87.0 85.0 0.88 0.86 0.78 650 250 185 75 0.13 121
9.3 12.5 4 ND160M 1460 19.0 17.5 88.0 88.0 86.0 0.85 0.81 0.73 600 225 170 65 0.31 121
9.3 12.5 6 ND160L 970 20.0 18..5 88.0 88.0 85.0 0.80 0.76 0.68 550 225 155 65 0.59 143
9.3 12.5 8 ND180M 710 22.0 20..0 86.0 86.0 84.0 0.76 0.72 0.64 500 200 140 60 0.99 182

5 5
TEFC
SQUIRREL CAGE
MOTORS

PERFORMANCE DATA (Continued)


P
OUTPUT FL FL EFFICIENCY (%) POWER FACTOR DOL STG. S/D STG. NETT
O FL GD²
FRAME AMPS AMPS WEIGHT
L RPM 3/4 1/2 3/4 1/2 STG. C STG. T STG. C STG. T KgM²
kW HP 380 V 415 V FL FL Kg.
E FL FL FL FL %FLC %FLT % FLC % FLT
11.0 15.0 2 ND160M 2920 22.0 20.0 88.0 88.0 86.0 0.88 0.86 0.78 650 250 185 75 0.13 121
11.0 15.0 4 ND160M 1460 22.0 20.0 89.0 89.0 86.0 0.85 0.82 0.74 600 225 170 65 0.36 121
11.0 15.0 6 ND160L 970 24.0 21.5 88.5 88.5 86.5 0.80 0.76 0.68 550 225 155 65 0.64 143
11.0 15.0 8 ND180L 710 25.0 23.0 87.0 87.0 85.0 0.77 0.73 0.65 500 200 140 60 1.16 204
15.0 20.0 2 ND160M 2920 29.0 26.5 89.5 89.5 87.5 0.88 0.86 0.79 650 250 185 75 0.17 121
15.0 20.0 4 ND160L 1460 29.0 27.0 90.0 90.0 88.0 0.86 0.83 0.75 600 225 170 65 0.47 143
15.0 20.0 6 ND180L 955 30.0 28.0 89.0 89.0 87.0 0.84 0.82 0.73 600 250 170 75 1.16 204
15.0 20.0 8 ND200L 725 36.0 33.0 88.5 88.5 86.5 0.71 0.65 0.55 500 225 140 65 2.15 254
18.5 25.0 2 ND160L 2920 35.0 33.0 90.0 90.0 88.0 0.88 0.86 0.79 650 250 185 75 0.21 143
18.5 25.0 4 ND180M 1465 36.0 33.0 91.0 91.0 89.5 0.86 0.84 0.77 600 225 170 65 0.81 174
18.5 25.0 6 ND200L 975 37.0 34.0 91.1 91.1 89.9 0.84 0.82 0.73 550 250 155 75 1.69 254
18.5 25.0 8 ND225S 725 42.0 39.0 89.0 89.0 87.0 0.75 0.71 0.63 500 180 140 50 3.24 350
22.0 30.0 2 ND180M 2920 40.0 37.0 91.0 91.0 89.0 0.92 0.92 0.84 650 275 185 85 0.44 174
22.0 30.0 4 ND180L 1465 42.0 39.0 91.0 91.0 89.5 0.87 0.84 0.77 600 225 170 65 0.95 204
22.0 30.0 6 ND200L 975 43.0 40.0 91.5 91.5 90.1 0.84 0.82 0.73 550 225 155 65 2.02 254
22.0 30.0 8 ND225M 725 50.0 46.0 89.0 89.0 87.0 0.75 0.71 0.63 500 250 140 75 3.61 380
30.0 40.0 2 ND200L 2940 55.0 51.5 91.5 91.5 90.0 0.91 0.89 0.87 650 225 185 65 0.79 254
30.0 40.0 4 ND200L 1475 56.0 51.0 92.0 92.0 90.2 0.89 0.86 0.78 600 250 170 75 1.70 254
30.0 40.0 6 ND225M 975 58.0 53.0 92.0 92.0 90.5 0.85 0.82 0.73 550 200 155 60 3.61 380
30.0 40.0 8 ND250S ** 735 67.0 61.5 90.5 90.5 88.5 0.75 0.71 0.63 550 200 155 60 6.36 460
30.0 40.0 8 ND250M 735 67.0 61.5 90.5 90.5 88.5 0.75 0.71 0.63 550 200 155 60 6.36 500
37.0 50.0 2 ND200L 2940 67.0 61.0 92.5 92.5 91.6 0.91 0.89 0.87 650 225 185 65 0.89 254
37.0 50.0 4 ND225S 1475 68.0 62.0 92.5 92.5 91.6 0.90 0.89 0.80 600 250 170 75 2.64 350
37.0 50.0 6 ND250S ** 980 72.0 66.0 93.0 93.0 92.0 0.84 0.81 0.72 600 250 170 75 4.82 460
37.0 50.0 6 ND250M 980 72.0 66.0 93.0 93.0 92.0 0.84 0.81 0.72 600 250 170 75 4.82 500
37.0 50.0 *8 ND250M ** 735 83.0 76.0 90.5 90.5 88.5 0.75 0.71 0.63 550 200 140 60 6.36 500
37.0 50.0 8 ND280S 735 81.0 75.0 91.5 91.5 89.5 0.76 0.71 0.63 500 210 140 60 8.01 620
45.0 60.0 2 ND225M 2950 80.0 74.0 92.5 92.5 91.1 0.92 0.90 0.88 650 225 185 65 1.87 380
45.0 60.0 4 ND225M 1475 82.0 75.0 93.0 93.0 91.5 0.90 0.89 0.80 600 250 170 75 3.11 380
45.0 60.0 *6 ND250M ** 980 88.0 80.0 93.0 93.0 92.0 0.84 0.81 0.72 600 250 170 75 6.36 500
45.0 60.0 6 ND280S 980 86.0 79.0 93.0 93.0 91.9 0.85 0.82 0.73 550 250 155 75 8.01 620
45.0 60.0 8 ND280S ** 740 99.0 91.0 92.0 92.0 90.5 0.75 0.71 0.63 500 210 140 60 9.89 700
45.0 60.0 8 ND280M 740 99.0 91.0 92.0 92.0 90.5 0.75 0.71 0.63 500 210 140 60 9.89 700
55.0 75.0 2 ND250S ** 2950 100.0 92.0 92.5 92.5 90.5 0.90 0.86 0.78 600 180 170 50 2.79 460
55.0 75.0 2 ND250M 2950 100.0 92.0 92.5 92.5 90.5 0.90 0.86 0.78 600 180 170 50 2.79 500
55.0 75.0 4 ND250S ** 1475 104.0 95.0 93.5 93.5 92.0 0.86 0.82 0.74 600 250 170 75 3.45 460
55.0 75.0 4 ND250M 1475 104.0 95.0 93.5 93.5 92.0 0.86 0.82 0.74 600 250 170 75 3.45 500
55.0 75.0 6 ND280S ** 980 104.0 95.0 93.5 93.5 92.5 0.86 0.82 0.74 600 200 170 60 8.01 620
55.0 75.0 6 ND280M 980 104.0 95.0 93.5 93.5 92.5 0.86 0.82 0.74 600 200 170 60 9.89 700
55.0 75.0 *8 ND280M ** 740 121.0 111.0 92.0 92.0 90.5 0.75 0.71 0.63 500 175 140 60 9.89 700
55.0 75.0 8 ND315S 740 116.0 106.0 92.5 92.5 91.0 0.78 0.74 0.66 600 200 170 60 14.12 1056
75.0 100.0 *2 ND250M ** 2950 134.0 123.0 92.5 92.5 90.5 0.92 0.88 0.80 600 180 170 50 2.79 500
75.0 100.0 2 ND280S 2960 135.0 124.0 93.5 93.5 92.0 0.90 0.86 0.78 600 225 170 65 6.63 620
75.0 100.0 *4 ND250M ** 1475 142.0 130.0 93.5 93.5 92.0 0.86 0.82 0.74 600 250 170 75 3.45 500
75.0 100.0 4 ND280S 1480 136.0 125.0 94.0 94.0 92.5 0.89 0.87 0.85 600 250 170 75 7.21 620
75.0 100.0 *6 ND280M ** 980 142.0 130.0 93.5 93.5 92.5 0.86 0.82 0.74 600 200 155 75 9.89 700
75.0 100.0 6 ND315S 980 141.0 129.0 94.0 94.0 92.5 0.86 0.82 0.74 600 225 170 65 14.12 1056
75.0 100.0 8 ND315S ** 740 157.0 144.0 93.0 93.0 91.5 0.78 0.74 0.66 600 200 140 60 14.57 1056
75.0 100.0 8 ND315M 740 157.0 144.0 93.0 93.0 91.5 0.78 0.74 0.66 600 200 170 60 18.98 1130
90.0 120.0 2 ND280S ** 2960 162.0 148.0 94.0 94.0 92.5 0.90 0.86 0.78 600 250 170 75 8.18 700
90.0 120.0 2 ND280M 2960 162.0 148.0 94.0 94.0 92.5 0.90 0.86 0.78 600 250 170 75 8.18 700
90.0 120.0 4 ND280S** 1480 161.0 147.0 94.5 94.5 93.0 0.90 0.88 0.86 600 250 170 75 7.21 620
90.0 120.0 4 ND280M 1480 161.0 147.0 94.5 94.5 93.0 0.90 0.88 0.86 600 250 170 75 8.25 700
90.0 120.0 6 ND315S ** 985 169.0 155.0 94.2 94.2 93.0 0.86 0.82 0.74 600 250 170 75 12.89 1056
90.0 120.0 6 ND315M 985 169.0 155.0 94.2 94.2 93.0 0.86 0.82 0.74 600 225 170 65 17.00 1130
90.0 120.0 *8 ND315M ** 740 187.0 171.0 94.0 94.0 92.0 0.78 0.74 0.66 600 250 170 60 18.97 1130
90.0 120.0 8 ND315L 740 187.0 171.0 94.0 94.0 92.0 0.78 0.74 0.66 600 250 170 60 29.94 1200

6 6
TEFC
SQUIRREL CAGE
MOTORS

PERFORMANCE DATA (Continued)


P
OUTPUT FL FL EFFICIENCY (%) POWER FACTOR DOL STG. S/D STG. NETT
O FL GD²
FRAME AMPS AMPS WEIGHT
L RPM 3/4 1/2 3/4 1/2 STG. C STG. T STG. C STG. T KgM²
kW HP 380 V 415 V FL FL Kg.
E FL FL FL FL %FLC %FLT % FLC % FLT
110.0 150.0 *2 ND280M ** 2960 200.0 183.0 93.0 93.0 91.0 0.90 0.86 0.78 600 225 170 65 8.18 700
110.0 150.0 2 ND315S 2970 193.0 177.0 94.0 94.0 92.5 0.92 0.86 0.78 600 200 170 60 11..55 1056
110.0 150.0 *4 ND280M ** 1480 197.0 180.0 94.5 94.5 93.0 0.90 0.88 0.86 600 250 170 75 8.26 700
110.0 150.0 4 ND315S 1488 197.0 180.0 94.5 94.5 92.0 0.90 0.88 0.86 600 225 170 65 11..62 1056
110.0 150.0 6 ND315M 985 206.0 189.0 94.5 94.5 93.5 0.86 0.82 0.74 600 225 170 65 18.98 1130
110.0 150.0 *8 ND315M ** 740 228.0 209.0 94.0 94.0 92.0 0.78 0.74 0.66 600 250 170 60 18.97 1130
110.0 150.0 8 ND315L 740 228.0 209.0 94.0 94.0 92.5 0.78 0.74 0.66 600 250 170 75 29.94 1200
132.0 175.0 2 ND315S ** 2970 236.0 216.0 94.5 94.5 93.0 0.90 0.86 0.78 650 250 185 75 13..89 1130
132.0 175.0 2 ND315M 2970 236.0 216.0 94.5 94.5 93.0 0.90 0.86 0.78 650 250 185 75 13.89 1130
132.0 175.0 4 ND315S ** 1488 229.0 210.0 95.0 95.0 94.0 0.92 0.90 0.88 600 225 170 75 11..62 1056
132.0 175.0 4 ND315M 1488 229.0 210.0 95.0 95.0 94.0 0.92 0.90 0.88 600 225 170 75 13.98 1130
132.0 175.0 *6 ND315M ** 985 248.0 227.0 94.0 94.0 93.0 0.86 0.82 0.74 600 225 170 65 18.98 1130
132.0 175.0 6 ND315L 985 247.0 226.0 94.5 94.5 93.5 0.86 0.82 0.74 600 250 170 75 29.94 1200
132.0 175.0 8 ND315L 740 272.0 250.0 94.5 94.5 92.5 0.78 0.74 0.66 600 225 170 65 33.28 1200
160.0 215.0 *2 ND315M ** 2970 281.0 241.0 94.0 94.0 93.0 0.92 0.86 0.78 650 250 185 75 13..89 1130
160.0 215.0 2 ND315L 2980 272.0 249.0 95.0 95.0 93.5 0.94 0.92 0.90 650 200 185 60 14.30 1200
160.0 215.0 *4 ND315M** 1488 280.0 210.0 94.5 94.5 93.0 0.92 0.90 0.88 600 225 170 75 13..98 1130
160.0 215.0 4 ND315L 1485 283.0 260.0 95.3 95.3 94.0 0.90 0.86 0.78 600 250 170 75 27.88 1200
160.0 215.0 6 ND315L 990 299.0 274.0 94.5 94.5 93.5 0.86 0.82 0.74 600 250 170 75 29.94 1200
160.0 215.0 8 ND355L 740 321.0 297.0 94.8 92.5 89.5 0.8 0.74 0.6 600 150 170 40 57.28 2150
200.0 270.0 2 ND315L 2980 339.0 310.0 95.5 95.5 94.0 0.94 0.92 0.90 650 200 170 60 17.82 1200
200.0 270.0 4 ND315L 1485 354.0 324.0 95.5 95.5 94.0 0.90 0.86 0.78 600 250 170 75 33.48 1200
200.0 270.0 6 ND355L 991 378.0 346.0 94.5 93.5 91.0 0.85 0.81 0.72 600 165 170 45 57.28 2125
225.0 302.0 2 ND355L 2982 395.0 362.0 94.0 93.0 90.0 0.92 0.89 0.82 650 150 185 40 21.63 1885
225.0 302.0 4 ND355L 1490 414.0 380.0 94.8 94.0 91.5 0.87 0.82 0.73 600 175 170 50 38.75 2050
225.0 302.0 6 ND355L 991 426.0 390.0 94.5 93.5 91.0 0.85 0.81 0.72 600 165 170 45 57.28 2125
250.0 335.0 2 ND355L 2978 437.0 400.0 94.5 93.5 90.1 0.92 0.89 0.82 650 150 185 40 23.56 1885
250.0 335.0 4 ND355L 1490 462.0 423.0 94.5 93.5 91.0 0.87 0.82 0.73 600 175 170 50 42.21 2050
250.0 335.0 6 ND355L 991 473.0 433.0 94.5 93.5 91.0 0.85 0.81 0.72 600 165 170 45 57.28 2125

** These Frames are for Australian


Standards AS1359 / AS1360 or South
African Standard SABS 948 Part I-1978.
* These outputs have Class ‘F’ temperature
rise.
The above data is subject to tolerance as
per the applicable standard.
FL - Full Load, STG - Starting, C - Current,
T - Torque, DOL - Direct on Line,
S/D-Star/Delta

7 7
TEFC
SQUIRREL CAGE
MOTORS

SHIPPING SPECIFICATIONS
FOOT MOUNTED MOTORS
NETT WEIGHT GROSS WEIGHT DIMENSIONS VOLUME
FRAME KG KG L IN MM B IN MM H IN MM CUBIC METRES
Wooden Carton Wooden Carton Wooden Carton Wooden Carton Wooden Carton Wooden Carton
AD63 5.6 7.5 235 155 205 0.0075
AD71 7.0 9.0 275 175 220 0.0106
AD80 10.0 13.0 325 210 240 0.0164
AD90S 13.0 17.0 375 220 290 0.0239
AD90L 16.0 20.0 375 220 290 0.0239
AD100L 19.0 24.0 400 245 305 0.0299
ND100LX 35.0 40.0 425 305 275 0.0356
ND112M 42.0 42.0 59.0 48.0 525 480 410 360 355 325 0.0764 0.0562
ND112MX 45.0 45.0 62.0 51.0 525 480 410 360 355 325 0.0764 0.0562
ND132S 68.0 68.0 92.0 76.0 625 550 445 400 410 380 0.1140 0.0836
ND132M 79.0 79.0 103.0 88.0 625 550 445 400 410 380 0.1140 0.0836
ND160M 121 179 750 585 545 0.239
ND160L 143 209 820 585 545 0.261
ND180M 174 250 875 705 585 0.361
ND180L 204 280 875 705 585 0.361
ND200L 254 366 1025 825 700 0.592
ND225S 350 462 1025 825 700 0.592
ND225M 380 492 1025 825 700 0.592
ND250S 460 586 1150 845 710 0.690
ND250M 500 628 1150 845 710 0.690
ND280S 620 766 1300 915 745 0.886
ND280M 700 846 1300 915 745 0.886
ND315S 1056 1319 1600 1170 925 1.732
ND315M 1130 1393 1600 1170 925 1.732
ND315L 1200 1475 1700 1170 940 1.870
ND355L 2150 2553 1900 1375 1325 3.462

FLANGE MOUNTED MOTORS


NETT WEIGHT GROSS WEIGHT DIMENSIONS VOLUME
FRAME KG KG L IN MM B IN MM H IN MM CUBIC METRES
Wooden Carton Wooden Carton Wooden Carton Wooden Carton Wooden Carton Wooden Carton
AD63D 5.6 7.5 275 175 220 0.0106
AD71D 7.0 9.0 325 210 240 0.0164
AD80D 10.0 13.0 385 290 250 0.0279
AD90SD 15.0 19.0 425 305 275 0..0356
AD90LD 18.0 22.0 425 305 275 0.0356
AD100LD 21.0 26.0 430 330 315 0.0447
ND100LXD 37.0 42.0 430 330 315 0.0447
ND112MD 45.0 45.0 72.0 51.0 555 480 445 360 405 325 0.1000 0.0562
ND112MXD 48.0 48.0 75.0 54.0 555 480 445 360 405 325 0.1000 0.0562
ND132SD 71.0 71.0 108.0 79.0 660 530 490 400 465 380 0.1504 0.0806
ND132MD 82.0 82.0 119.0 91.0 660 585 490 400 465 380 0.1504 0.0889
ND160MD 127 204 865 630 665 0.362
ND160LD 148 225 865 630 665 0.362
ND180MD 181 258 865 630 665 0.362
ND180LD 215 292 865 630 665 0.362
ND200LD 258 406 1065 885 840 0.792
ND225SD 363 511 1065 885 840 0.792
ND225MD 393 541 1065 885 840 0.792
ND250SD 461 705 990 900 1245 1.109
ND250MD 507 745 990 900 1245 1.109
ND280SD 620 898 1070 1070 1430 1.637
ND280MD 700 978 1070 1070 1430 1.637
ND315SD 1086 1424 1280 1210 1545 2.393
ND315MD 1160 1498 1280 1210 1545 2.393
ND315LD 1200 1624 1850 1450 1275 3.420

8 8
TEFC
SQUIRREL CAGE
MOTORS

SHIPPING SPECIFICATIONS (Continued)


FOOT MOUNTED MOTORS WITH TERMINAL
BOX ON TOP
NETT WEIGHT GROSS WEIGHT DIMENSIONS VOLUME
FRAME KG KG L IN MM B IN MM H IN MM CUBIC METRES
Wooden Carton Wooden Carton Wooden Carton Wooden Carton Wooden Carton Wooden Carton

ND160M 121 184 875 525 600 0.276


ND160L 143 206 875 525 600 0.276
ND180M 174 246 930 630 645 0.378
ND180L 204 276 930 630 645 0.378
ND200L 254 368 1275 725 790 0.730
ND225S 350 464 1275 725 790 0.730
ND225M 380 494 1275 725 790 0.730
ND250S 460 601 1450 785 890 1.013
ND250M 500 641 1450 785 890 1.013
ND280S 620 761 1450 785 890 1.013
ND280M 700 841 1450 785 890 1.013
ND315S 1056 1306 1730 920 1065 1.695
ND315M 1130 1380 1730 920 1065 1.695
ND315L 1200 1480 1830 1000 1115 2.040

The standard packing is in carton when


available, alternatively it is wooden.
The carton packing is for full container
shipment.
The shipping specifications for face
mounting motors would be similar to those
of flange mounting motors.

9 9
TEFC
SQUIRREL CAGE
MOTORS

DIMENSIONS OF FOOT MOUNTING MOTORS


IN ALUMINIUM FRAMES AD63 AND AD71

L
Ø AC
CABLE ENTRY
SCREWED FOR
TAPPED HOLE KK BS CONDUIT FOR
Y × DEPTH CABLE GLAND
GE
N9/h9
X ED ED X
F
HD

D D H

G GD

BA AA
GA 4 HOLES HA
E C B E A
K DIA
BB AB

FOOT FIXING SHAFT AND KEY OVERALL (MAX.)


FRAME
A B C H AA AB BA BB K HA D E ED F G GA GD GE X Y × Depth AC L HD KK

AD63 100 80 40 63 25.5 122 – 96 7 9 11 23 18 4 8.5 12.5 4 2.5 2..5 M4×10 125 210 160 3/4"

AD71 112 90 45 71 30 136 – 110 7 9 14 30 25 5 11 16 5 3 2.5 M5×12.5 145 250 175 3/4"

TOLERANCE

ON GRADE RANGE TOLERANCE ON GRADE RANGE TOLERANCE


CENTRE HEIGHT KEYWAY

+ 0.0
H – ALL + 0.0
– 0.5 F N9 3 TO 6
– 0.030
SHAFT

+ 0.2
ED – UP TO 28 – 0.0
+ 0.008
D j6 11 TO 18 – 0.003
KEY
+ 0.1
GE – UP TO 3.5 – 0.0 F h9 + 0.0
3 TO 6
– 0.030
1. All dimensions are in mm, unless specified.
2. Cable entries can be rotated through 360° in
GD 3 TO 6 + 0.0
steps of 90°. h9
– 0.030
3. Compression type cable glands can be fitted
when specified.
4. All dimensions are subject to confirmation.
Certified Drawings will be sent on request.

10
TEFC
SQUIRREL CAGE
MOTORS

DIMENSIONS OF FLANGE MOUNTING MOTORS


IN ALUMINIUM FRAMES AD63 AND AD71

L
R
E LB E
CABLE ENTRY
TAPPED HOLE SCREWED FOR KK
Y X DEPTH X ED ED X BS CONDUIT FOR
CABLE GLAND
GE N9/h9
F HB

D Ø N Ø AC
SPIGOT
D D
45°
G GD

GA
P T LA
4 HOLES DRILLED Ø S
EQUALLY SPACED ON
M DIA. CIRCLE

FLANGE FIXING SHAFT AND KEY OVERALL (MAX.)


FRAME
M N P R S T LA D E ED F G GA GD GE X Y×Depth AC L LB HB KK

AD63D 115 95 140 0 10 3 9 11 23 18 4 8.5 12.5 4 2.5 2.5 M4×10 125 220 197 100 3/4 ''

AD71D 130 110 160 0 10 3.5 9 14 30 25 5 11 16 5 3 2.5 M5×12.5 145 250 220 105 3/4 ''

TOLERANCE

ON GRADE RANGE TOLERANCE ON GRADE RANGE TOLERANCE


P.C.D. KEYWAY

M – UP TO 265 ± 0.03
3 TO 6 + 0.0
F N9
– 0.030
SPIGOT

+ 0.013 ED – + 0.2
N j6 UP TO 28
95 TO 110 – 0.009 – 0.0

KEY
SHAFT

F h9 3 TO 6 + 0.0
D j6 + 0.008 – 0.030
11 TO 18 – 0.003

GD h9 3 TO 6 + 0.0
+ 0.1
GE – UP TO 3.5 – 0.030
– 0.0

1. All dimensions are in mm, unless specified.


2. Cable entries can be rotated through 360° in
steps of 90°.
3. Compression type cable glands can be fitted
when specified.
4. All dimensions are subject to confirmation.
Certified Drawings will be sent on request.

11
TEFC
SQUIRREL CAGE
MOTORS

DIMENSIONS OF FACE MOUNTING MOTORS


IN ALUMINIUM FRAMES AD63 AND AD71

L CABLE ENTRY
SCREWED FOR
LB KK BS CONDUIT
R
45° FOR CABLE GLAND
TAPPED HOLE
Y × DEPTH
GE
N9/h9 X ED
HB ED X
F

D Ø AC
Ø N
SPIGOT
Ø P D D

G GD

GA E
4 HOLES TAPPED S Ø × LA DEEP EQUALLY E
SPACED ON M DIA CIRCLE T

FACE FIXING SHAFT AND KEY OVERALL (MAX.)


FRAME
M N P R S T LA D E ED F G GA GD GE X Y×Depth AC L LB HB KK

AD63C 75 60 90 0 M5 2.5 8 11 23 18 4 8.5 12.5 4 2.5 2.5 M4×10 125 220 197 100 3/4''

AD71C 85 70 105 0 M6 2.5 10 14 30 25 5 11 16 5 3 2.5 M5×12.5 145 250 215 105 3/4''

TOLERANCE

ON GRADE RANGE TOLERANCE ON GRADE RANGE TOLERANCE


P.C.D. KEYWAY

M – UP TO 165 ± 0.3 + 0.0


F N9 3 TO 6
– 0.030
SPIGOT

+ 0.012 + 0.2
N j6 50 TO 80 ED – UP TO 28 – 0.0
– 0.007

KEY
SHAFT
+ 0.0
F h9 3 TO 6 – 0.030
D j6 + 0.008
11 TO 18
– 0.003

+ 0.0
+ 0.1 GD h9 3 TO 6
GE – UP TO 3.5 – 0.030
– 0.0

1. All dimensions are in mm, unless specified.


2. Cable entries can be rotated through 360° in
steps of 90°.
3. Compression type cable glands can be fitted
when specified.
4. All dimensions are subject to confirmation.
Certified Drawings will be sent on request.

12
TEFC
SQUIRREL CAGE
MOTORS

DIMENSIONS OF FOOT MOUNTING MOTORS


IN ALUMINIUM FRAME AD80

L Ø AC

TAPPED HOLE
CABLE ENTRY
Y × DEPTH SCREWED FOR
GE KK BS CONDUIT
N9/h9 FOR CABLE GLAND
F ED ED
HD

D D
H

G GD
4 SLOTTED
BA HOLES ØK × V AA
GA LONG HA
E C B E A

BB AB
ØK

FOOT FIXING SHAFT AND KEY OVERALL (MAX.)


FRAME
A B C H AA AB BA BB K V HA D E ED F G GA GD GE Y×Depth AC L HD KK

AD 80 125 100 50 80 28 152 35 125 10 14 11 19 40 27 6 15.5 21.5 6 3.5 M6×16 165 285 200 3/4"

TOLERANCE

ON GRADE RANGE TOLERANCE ON GRADE RANGE TOLERANCE


CENTRE HEIGHT KEYWAY

+ 0.0
H – ALL + 0.0
– 0.5 F N9 3 TO 6 – 0.030
SHAFT

ED – UP TO 28 + 0.2
j6 + 0.009 – 0.0
D 19 TO 28
– 0.004
KEY
+ 0.1
GE – UP TO 3.5 + 0.0
- 0.0 F h9 3 TO 6
– 0.030

GD h9 + 0.0
3 TO 6 – 0.030

1. All dimensions are in mm, unless specified.


2. Cable entries can be rotated through 360° in
steps of 90°.
3. Compression type cable glands can be fitted
when specified.
4. All dimensions are subject to confirmation.
Certified Drawings will be sent on request.

13
TEFC
SQUIRREL CAGE
MOTORS

DIMENSIONS OF FLANGE MOUNTING MOTORS


IN ALUMINIUM FRAME AD80

L
R CABLE ENTRY
P E LB SCREWED FOR KK
45°
TAPPED HOLE BS CONDUIT FOR
CABLE GLAND
Y × DEPTH

GE N9/h9
F HB ED ED

Ø N
D Ø AC
SPIGOT
D D

G GD

GA
T LA E
4 HOLES DRILLED S DIA
EQUALLY SPACED ON M
DIA CIRCLE

FLANGE FIXING SHAFT AND KEY OVERALL (MAX.)


FRAME
M N P R S T LA D E ED F G GA GD GE Y×Depth AC L LB HB KK

AD80D 165 130 200 0 12 3.5 10 19 40 27 6 15.5 21.5 6 3.5 M6×16 165 285 245 120 3/4 "

TOLERANCE

ON GRADE RANGE TOLERANCE ON GRADE RANGE TOLERANCE


P.C.D. KEYWAY

M – UP TO 265 ± 0.3 + 0.0


F N9 3 TO 6
– 0.030
SPIGOT

+ 0.014 + 0.2
N j6 120 TO 180 ED – UP TO 28
– 0.011 – 0.0

KEY
SHAFT
+ 0.0
F h9 3 TO 6 – 0.030
D j6 19 TO 28 + 0.009
– 0.004

GD h9 + 0.0
+ 0.1 3 TO 6
GE – UP TO 3.5 – 0.030
- 0.0

1. All dimensions are in mm, unless specified.


2. Cable entries can be rotated through 360° in
steps of 90°.
3. Compression type cable glands can be fitted
when specified.
4. All dimensions are subject to confirmation.
Certified Drawings will be sent on request.

14
TEFC
SQUIRREL CAGE
MOTORS

DIMENSIONS OF FACE MOUNTING MOTORS


IN ALUMINIUM FRAME AD80

L
CABLE ENTRY
R SCREWED FOR
LB
E KK BS CONDUIT
45°
FOR CABLE GLAND
TAPPED HOLE
Y × DEPTH
GE
N9/h9 HB ED
F ED

Ø N Ø AC
D
SPIGOT
P D D

G GD

GA
4 HOLES TAPPED Ø S ×LA DEEP T E
EQUALLY SPACED ON M DIA CIRCLE

FACE FIXING SHAFT AND KEY OVERALL (MAX.)


FRAME
M N P R S T LA D E ED F G GA GD GE Y×Depth AC L LB HB KK

AD80C 100 80 120 0 M6 3 15 19 40 27 6 15.5 21.5 6 3.5 M6×16 165 285 245 120 3/4 "

TOLERANCE

ON GRADE RANGE TOLERANCE ON GRADE RANGE TOLERANCE


P.C.D. KEYWAY

M – UP TO 265 ± 0.3 + 0.0


F N9 3 TO 6
– 0.030
SPIGOT

+ 0.012 ED – + 0.2
N j6 50 TO 80 UP TO 28
– 0.007 – 0.0

KEY
SHAFT

+ 0.0
F h9 3 TO 6
D + 0.009 – 0.030
j6 19 TO 28 – 0.004

+ 0.1 GD + 0.0
GE – h9 3 TO 6
UP TO 3.5 – 0.030
– 0.0

1. All dimensions are in mm, unless specified.


2. Cable entries can be rotated through 360° in
steps of 90°.
3. Compression type cable glands can be fitted
when specified.
4. All dimensions are subject to confirmation.
Certified Drawings will be sent on request.

15
TEFC
SQUIRREL CAGE
MOTORS

DIMENSIONS OF FOOT MOUNTING MOTORS


IN ALUMINIUM FRAMES AD90 AND AD100

L Ø AC
CABLE ENTRY
SCREWED FOR
KK BS CONDUIT
FOR CABLE GLAND
TAPPED HOLE E
Y × DEPTH GE
ED
N9/h9 ED
F HD

D D
H
G GD HA

GA
AA
BA
E C B A 4 SLOTTED
HOLES
ØK × V LONG
BB AB

FOOT FIXING SHAFT AND KEY OVERALL (MAX.)


FRAME
A B C H AA AB BA BB ØK V HA D E ED F G GA GD GE Y×Depth AC L HD KK

AD90S 100 126 310


140 56 90 40 170 30 10 15 13 24 50 36 8 20 27 7 4 M8×19 190 230 1"
AD90L 125 151 335

AD100L 160 140 63 100 48 192 35 170 12 16 13 28 60 44 8 24 31 7 4 M10×22 205 360 250 1"

TOLERANCE

ON GRADE RANGE TOLERANCE ON GRADE RANGE TOLERANCE


CENTRE HEIGHT KEYWAY
+ 0.0
H – ALL + 0.0
– 0.5 F N9 8 TO 10
– 0.036
SHAFT

+ 0.3
+ 0.009 ED – 32 TO 80 – 0.0
D j6 19 TO 28
– 0.004
KEY
+ 0.2
GE – 4 & ABOVE + 0.0
– 0.0 F h9 8 TO 10
– 0.030
1. All dimensions are in mm, unless specified.
2. Cable entries can be rotated through 360° in
steps of 90°. h11 + 0.0
GD 7 TO 10
3. Compression type cable glands can be fitted – 0.090
when specified.
4. All dimensions are subject to confirmation.
Certified Drawings will be sent on request.

16
TEFC
SQUIRREL CAGE
MOTORS

DIMENSIONS OF FLANGE MOUNTING MOTORS


IN ALUMINIUM FRAMES AD90 AND AD100

L CABLE ENTRY
SCREWED FOR
E R KK BS CONDUIT
FOR CABLE GLAND
TAPPED HOLE
Y × DEPTH GE AD E
N9/h9 45° ED ED
F
Ø N
D Ø AC
SPIGOT
D D

G GD P

GA
4 HOLES DRILLED EARTHING HOLE ON
Ø S EQUALLY SPACED T LA BOTH SIDES OF MOTOR
ON M DIA. CIRCLE BODY
LB

FLANGE FIXING SHAFT AND KEY OVERALL (MAX.)


FRAME

M N P R S T LA D E ED F G GA GD GE Y×Depth AD AC L LB KK

AD90SD 310 260


165 130 200 0 12 3.5 10 24 50 36 8 20 27 7 4 M8×19 140 190 1"
AD90LD 335 285

AD100LD 215 180 250 0 15 4 11 28 60 44 8 24 31 7 4 M10×22 150 205 360 300 1"

TOLERANCE

ON GRADE RANGE TOLERANCE ON GRADE RANGE TOLERANCE


PCD KEYWAY

M – UP TO 265 ± 0.3 + 0.0


F N9 8 TO 10
– 0.036
SPIGOT

+ 0.014 + 0.3
N j6 120 TO 180 ED – 32 TO 80
– 0.011 – 0.0

SHAFT KEY

F h9 + 0.0
j6 + 0.009 8 TO 10
D 19 TO 28 – 0.030
– 0.004

+ 0.2 GD h11 + 0.0


GE – 4 & ABOVE 7 TO 10
– 0.0 – 0.090

1. All dimensions are in mm, unless specified.


2. Cable entries can be rotated through 360° in
steps of 90°.
3. Compression type cable glands can be fitted
when specified.
4. All dimensions are subject to confirmation.
Certified Drawings will be sent on request.

17
TEFC
SQUIRREL CAGE
MOTORS

DIMENSIONS OF FACE MOUNTING MOTORS


IN ALUMINIUM FRAMES AD90 AND AD100

L CABLE ENTRY
45°
SCREWED FOR
KK BS CONDUIT
E R
FOR CABLE GLAND

TAPPED HOLE ED
GE AD
Y × DEPTH E
N9/h9
ED
F

D Ø N Ø AC
SPIGOT
Ø P D D
G
GD
GA

T EARTHING HOLE ON BOTH


4 HOLES TAPPED S × LA DEEP SIDES OF MOTOR BODY
EQUALLY SPACED ON M DIA CIRCLE
LB

FLANGE FIXING SHAFT AND KEY OVERALL (MAX.)


FRAME
M N P R S T LA D E ED F G GA GD GE Y×Depth AD AC L LB KK
AD90SC 310 260
115 95 140 0 M8 3 10 24 50 36 8 20 27 7 4 M8×19 140 190 1"
AD90LC 335 285

AD100 LC 130 110 160 0 M8 3.5 10 28 60 44 8 24 31 7 4 M10×22 150 205 360 300 1"

TOLERANCE

ON GRADE RANGE TOLERANCE ON GRADE RANGE TOLERANCE


P.C.D. KEYWAY

M – UP TO 265 ± 0.3 + 0.0


F N9 8 TO 10
– 0.036
SPIGOT

+ 0.013 + 0.3
N j6 80 TO 120 ED – 32 TO 80
– 0.009 – 0.0

KEY
SHAFT

+ 0.0
F h9 8 TO 10
j6 + 0.009 – 0.030
D 19 TO 28
– 0.004

h11 + 0.0
+ 0.2 GD 7 TO 10
GE – 4 & ABOVE – 0.090
– 0.0

1. All dimensions are in mm, unless specified.


2. Cable entries can be rotated through 360° in
steps of 90°.
3. Compression type cable glands can be fitted
when specified.
4. All dimensions are subject to confirmation.
Certified Drawings will be sent on request.

18
TEFC
SQUIRREL CAGE
MOTORS

DIMENSIONS OF FOOT MOUNTING MOTORS


IN FRAMES ND90 TO ND132

Ø AC
NO EYE BOLT
L E AD FOR ND 90 S/L

GE
TAPPED HOLE
Y × DEPTH N9 /h9 ED ED
F
HD
D HC

D D H
G GD

GA
BA HA AA
E C B CABLE ENTRIES A 4 HOLES
SCREWED FOR
BB 25.4 (1") BS CONDUIT AB K DIA.
FOR CABLE GLAND

FOOT FIXING SHAFT AND KEY OVERALL (MAX.)


FRAME
A B C H AA AB BA BB K HA D E ED F G GA GD GE Y×Depth AD AC L HC HD

ND90S 100 127 315


140 56 90 35 168 40 10 13 24 50 36 8 20 27 7 4 M8×19 150 190 185 –
ND90L 125 152 340

ND100LX 370
160 140 63 100 36 192 45 170 12 13 28 60 44 8 24 31 7 4 M10×22 160 210 205 250
ND100L 380

ND112MX 390
90 140 70 112 36 222 50 170 12 13 28 60 44 8 24 31 7 4 M10×22 170 230 230 275
ND112M 405

ND132S 140 178 470


216 89 132 48 254 54 12 16 38 80 60 10 33 41 8 5 M12×28 190 270 270 320
ND132M 178 216 510

TOLERANCE

ON GRADE RANGE TOLERANCE ON GRADE RANGE TOLERANCE


CENTRE HEIGHT KEYWAY

+ 0.0 + 0.0
H – ALL F N9 8 TO 10
– 0.036
– 0.5
ED – + 0.3
SHAFT 32 TO 80
– 0.0
j6 + 0.009 KEY
19 TO 28 – 0.004
D + 0.0
+ 0.018 F h9 8 TO 10
k6 32 TO 48 – 0.036
+ 0.002
+ 0.2 + 0.0
GE – 4 & ABOVE GD h11 7 TO 10
– 0.0 – 0.090

1. All dimensions are in mm, unless specified. 4. Compression type cable glands can be fitted
2. Cable entries can be rotated through 360° in when specified.
steps of 90°. 5. All dimensions are subject to confirmation.
3. One cable entry for DOL starting and two for star / Certified Drawings will be sent on request.
delta starting and multispeed motors are provided.

19
TEFC
SQUIRREL CAGE
MOTORS

DIMENSIONS OF FLANGE MOUNTING MOTORS


IN FRAMES ND90 TO ND132

AD L

R
45 LB E
° E
NO EYE BOLT FOR
ED ND 90 SD/LD ED
GE
P
TAPPED HOLE
Y × DEPTH
N9 / h9 HB
F

Ø N Ø AC
D
SPIGOT
D D

G GD
4 HOLE DRILLED
CABLE ENTRIES
GA S Ø EQUALLY SCREWED FOR
SPACED ON M 25.4 (1") BS CONDUIT LA
T
DIA CIRCLE FOR CABLE GLAND

FLANGE FIXING SHAFT AND KEY OVERALL (MAX.)


FRAME
M N P R S T LA D E ED F G GA GD GE Y×Depth AD AC L LB HB

ND90SD 335 285


165 130 200 0 12 3.5 10 24 50 36 8 20 27 7 4 M8×19 150 190 –
ND90LD 360 310

ND100LXD 370 310


215 180 250 0 15 4 11 28 60 44 8 24 31 7 4 M10×22 160 210 150
ND100LD 380 320

ND112MXD 390 330


215 180 250 0 15 4 11 28 60 44 8 24 31 7 4 M10×22 170 230 160
ND112MD 405 345

ND132SD 470 390


265 230 300 0 15 4 14 38 80 60 10 33 41 8 5 M12×28 190 270 190
ND132MD 510 430

TOLERANCE

ON GRADE RANGE TOLERANCE ON GRADE RANGE TOLERANCE


P.C.D. KEYWAY

M – UP TO 265 ± 0.3 + 0.0


F N9 8 TO 10 – 0.036
SPIGOT
+ 0.014 32 TO 80 + 0.3
ED –
120 TO 180 – 0.011 – 0.0
N j6
+ 0.016 KEY
180 TO 250
– 0.013
SHAFT 8 TO 10 + 0.0
F h9
– 0.030
j6 + 0.009
19 TO 28
– 0.004
D 7 TO 10 + 0.0
+ 0.018 GD h11
k6 32 TO 48 – 0.090
+ 0.002
– 0.2
GE – 4 & ABOVE – 0.0

1. All dimensions are in mm, unless specified. 4. Compression type cable glands can be fitted
2. Cable entries can be rotated through 360° in when specified.
steps of 90°. 5. All dimensions are subject to confirmation.
3. One cable entry for DOL starting and two for star / Certified Drawings will be sent on request.
delta starting and multispeed motors are provided.

20
TEFC
SQUIRREL CAGE
MOTORS

DIMENSIONS OF FACE MOUNTING MOTORS


IN FRAMES ND90 TO ND132

AD L

R
LB E
E
45 NO EYE BOLT FOR
° ND 90 SC/LC
ED ED
TAPPED HOLE GE
Y × DEPTH HB
N9 / h9
F

D Ø N
Ø AC
SPIGOT
D D

G GD
4 HOLES TAPPED CABLE ENTRIES
Ø S × LA DEEP SCREWED FOR
GA P 25.4 (1") BS CONDUIT LA
EQUALLY SPACED T
ON M DIA CIRCLE FOR CABLE GLAND

FACE FIXING SHAFT AND KEY OVERALL (MAX.)


FRAME
M N P R S T LA D E ED F G GA GD GE Y×Depth AD AC L LB HB

ND90SC 315 265


115 95 140 0 M8 3 10 24 50 36 8 20 27 7 4 M8×19 150 190 –
ND90LC 340 290

ND100LXC 370 310


130 110 160 0 M8 3.5 10 28 60 44 8 24 31 7 4 M10×22 160 210 150
ND100LC 380 320

ND112MXC 390 330


130 110 160 0 M8 3.5 10 28 60 44 8 24 31 7 4 M10×22 170 230 160
ND112MC 405 345

ND132SC 470 390


165 130 200 0 M10 3.5 12 38 80 60 10 33 41 8 5 M12×28 190 270 190
ND 132MC 510 430

TOLERANCE

ON GRADE RANGE TOL. ON GRADE RANGE TOL.


P.C.D. KEYWAY

M – UP TO 265 ± 0.3 + 0.0


F N9 8 TO 10
– 0.036
SPIGOT
+ 0.013
80 TO 120 – 0.009 + 0.3
N j6 ED – 32 TO 80
+ 0.014 – 0.0
120 TO 180
– 0.011
KEY
SHAFT

j6 + 0.009 + 0.0
19 TO 28 – 0.004 F h9 8 TO 10 – 0.030
D
k6 + 0.018
32 TO 48
+ 0.002
+ 0.0
+ 0.2 GD h11 7 TO 10 – 0.090
GE – 4 & ABOVE
– 0.0

1. All dimensions are in mm, unless specified. 4. Compression type cable glands can be fitted
2. Cable entries can be rotated through 360° in when specified.
steps of 90°. 5. All dimensions are subject to confirmation.
3. One cable entry for DOL starting and two for Certified Drawings will be sent on request.
star / delta starting and multispeed motors are
provided.

21
TEFC
SQUIRREL CAGE
MOTORS

DIMENSIONS OF FOOT MOUNTING MOTORS


IN FRAMES ND160 TO ND355 WITH TERMINAL BOX ON SIDE

CABLE DIVIDING BOX PROVIDED AUXILIARY TERMINAL BOX FOR SPACE HEATER
FOR ND 200 ONWARDS & THERMISTOR ABOVE 200 FRAME ONLY
'Y'THREADED
CENTRE HOLES
L±5 AC
Y × DEPTH
AD

N9/h9 F +0.0
-0.5
GD ED

HD

H
ØD

BA AA
E±0.5 C±1 B±0.5 HA
A±0.5
B'±0.5
AB
BB
CABLE ENTRY 4-HOLES 'K' DIA.
SCREWED FOR
'KK'B.S.CONDUIT EARTHING TERMINALS OF M8 SIZE ON
BOTH SIDES. THESE SHALL BE M12
FOR 280 AND 315 FRAMES.

FOOT FIXING SHAFT & KEY OVERALL (MAX.)


FRAME
A B B' C H TOL AA AB BA BB K TOL D TOL E ED F TOL GD TOL G Y×Depth AD AC L HD HA KK
ND160M 210 - 160.0 254 15.5 42.018 12.00 8.00 37.0 605

2 Nos.-1"
254 108 159.7 73 308 76 15.0 42.002 110 80 11.957 7.91 36.8 265 318 650 376 22
ND160L 254 - 298
M16×32
ND180M 241 - 180.0 286 15.5 48.018 14.00 9.00 42.5 668
279 121 84 348 95 110 80 285 352 418 22
ND180L 279 - 179.7 323 15.0 48.002 13.957 8.91 43.3 706
19.5 55.030 16.00 10.00 49.0
ND200L 318 305 - 133 200.0 64 381 104 356 110 80 345 405 775 464 25
199.5 19.0 55.011 15.957 9.91 48.8
ND225S 286 - 225.0 19.5 60.030 18.00 11.00 53.0

2 Nos.-1.5"
356 149 70 425 102 375 140 110 375 448 840 520 25
ND225M - 311 224.5 19.0 60.011 17.957 10.91 52.8

ND250S 311 - 250.0 24.5 65.030 18.00 11.00 58.0


406 168 80 483 135 419 140 110 M20×40 405 486 930 594 32
ND250M - 349 249.5 24.0 65.011 17.957 10.91 57.8
ND280S 368 - 280.0 24.5 75.030 20.00 12.00 67.5
457 190 100 538 198 487 140 110 430 540 1075 642 35
ND280M - 419 279.0 24.0 75.011 19.948 11.91 67.3
ND315S 406 - 315.0 28.5 80.030 22.00 14.00 71.0
2 Nos.-2"

508 216 110 597 164 533 170 140 510 590 1200 725 38
ND315M - 457 314.0 28.0 80.011 21.948 13.91 70.8

ND315L 315.0 28.5 90.035 25.00 14.00 81.0


508 508 - 216 110 610 230 740 170 140 570 645 1375 755 35
⊗ 314.0 28.0 90.013 24.948 13.91 80.8
M24×50
2Nos.-2.5"

ND355L 355.0 28.5 100.035 28.00 14.00 90.0 630 720 1570 827 40
610 630 - 254 110 710 250 857 210 160
⊗ 354.0 28.0 100.013 27.948 13.89 89.8

GD L
FRAME D E ED F TOLERANCE G
TOLERANCE S M L
ND16OM 55.030 / 55.011 110 80 16.0 / 15.957 10.0 / 9.91 49.0 / 49.8 810 810 –
ABOVE 200 FRAMES
MACHINES RUNNING ND16OL 60.030 / 60.011 140 110 18.0 / 17.957 11.0 / 10.91 53.0 / 52.8 930 930 –
AT 3000 RPM HAVE ND18OM 1075 1075 –
SMALLER SHAFTS 65.030 / 65.011 140 110 18.0 / 17.957 11.0 / 10.91 58.0 / 57.8
AS SHOWN HERE ND18OL 1170 1170 –
ND225S 70.030 / 70.011 140 110 20.0 / 19.948 12.0 / 11.91 62.0 / 62.3 – – 1345
ND225M 85.035 / 85.013 170 140 22.0 / 21.948 14.0 / 13.89 76.0 / 75.8 – – 1530
⊗ Frames having suffix 'S' are not available. For notes, please refer page 23.

22 22
TEFC
SQUIRREL CAGE
MOTORS

DIMENSIONS DRAWING OF FOOT MOUNTED MOTORS


IN FRAME ND355L

AUXILIARY TERMINAL BOX FOR SPACE


CABLE DIVIDING BOX PROVIDED HEATER & THERMISTORS ABOVE 200
FOR ND 200 ONWARDS FRAME ONLY
Y THREADED
CENTRE HOLES
L±5 AC
Y × DEPTH
AD

+0.0
N9/h9 F -0.5
ED
GD

HD
G

H
ØD

E±0.5 C±1.0 B±0.5 BA AA


HA
B"±0.5 A±0.5
BB AB

CABLE ENTRY SCREWED 4-HOLES 'K' DIA.


FOR 'KK' B.S.CONDUIT
EARTHING TERMINALS OF
M12 SIZE ON BOTH SIDES.

FOOT FIXING SHAFT AND KEY OVERALL (MAX.)


FRAME
A B B' C H TOL. AA AB BA BB K TOL. D TOL. E ED F TOL. GD TOL. G Y×Depth AD AC L HD HA KK

355.0 28.5 100.035 28.00 14.0 90.0 2 Nos


ND355L 610 630 – 254 110 710 250 857 210 160 M24×50 630 720 1620 827 40 2.5"
354.0 28.0 100.013 27.948 13.89 89.8

FRAME D TOLERANCE E ED F TOLERANCE GD TOLERANCE G L


MACHINES RUNNING
AT 3000 RPM HAVE
SMALLER SHAFTS ND355L 85.035/85.013 170 140 22.0/21.948 14.0/13.89 76.0/75.8 1570
AS SHOWN HERE

1. All dimensions are in mm, unless specified.


2. Cable entries can be rotated through 360° in
steps of 90°.
3. One cable entry shall be for DOL starting and
two for star / delta starting and multispeed
motors.
4. Compression type cable glands can be fitted
when specified.
5. All dimensions are subject to confirmation.
Certified Drawings will be sent on request.
6. Detailed stator and endshield fins are not shown
in the drawing.

23
TEFC
SQUIRREL CAGE
MOTORS

DIMENSIONS OF FOOT MOUNTING MOTORS


IN FRAMES ND160 TO ND315 WITH TERMINAL BOX ON TOP

CABLE ENTRY SCREWED FOR 'KK' CABLE DIVIDING BOX PROVIDED FOR
B.S.CONDUIT 200 FRAME ONWARDS
AUXILIARY TERMINAL BOX FOR SPACE HEATER/
'Y' THREADED THERMISTORS ABOVE 200 FRAME ONLY. 2-EYE BOLTS FOR
CENTRE HOLES AD 200 AND ABOVE
Y × DEPTH
L± 5 AC

N9 / h9
F
+0.0
GD -0.5
ED

HD

ØD H

BA HA AA
E ± 0.5 C ±1 B ±0.5
B' ± 0.5 4-HOLES 'K' DIA. A ± 0.5

BB AB

EARTHING TERMINALS OF M8 ON BOTH SIDES


AND M12 FOR 280-315 FRAMES

FOOT FIXING SHAFT & KEY OVERALL (MAX.)


FRAME
A B B' C H AA AB BA BB K D TOL E ED F TOL GD G Y×Depth AD AC L HD HA KK
TOL TOL TOL
ND160M 210 - 160.0 254 15.5 42.018 12.00 8.00 37.0 605
254 108 73 308 76 110 80 – 318 425 22

2Nos.-1"
ND160L 254 - 159.7 298 15.0 42.002 11.957 7.91 36.8 650
M16×32
ND180M 241 - 180.0 286 15.5 48.018 14.00 9.00 42.5 668
279 121 179.7 84 348 95 110 80 – 352 465 22
ND180L 279 - 323 15.0 48.002 13.957 8.91 42.3 706
200.0 19.5 55.030 16.00 10.00 49.0
ND200L 318 305 - 133 199.5 64 381 104 356 110 80 285 405 775 545 25
19.0 55.011 15.957 9.91 48.8
ND225S 286 - 225.0 19.5 60.030 140 110 18.00 11.00 53.0
356 149 70 425 102 375 285 448 840 600 25 2Nos.-1.5"
ND225M - 311 224.5 19.0 60.011 17.957 10.91 53.8
ND250S 311 - 250.0 24.5 65.030 18.00 11.00 58.0 M20×40 930
406 168 80 483 135 419 140 110 285 486 645 32
ND250M - 349 249.5 24.0 65.011 17.957 10.91 57.8 930

ND280S 368 - 280.0 24.5 75.030 20.00 12.00 67.5


457 190 100 538 198 487 140 110 285 540 1075 700 35
ND280M - 419 279.0 24.0 75.011 19.948 11.91 67.3

ND315S 406 - 315.0 28.5 80.030 22.00 14.00 71.0 1200


508 216 110 597 164 533 140
28.0 80.011 170 375 590 1200 845 38
2Nos.-2"

ND315M - 457 314.0 21.948 13.91 70.8

315.0 28.5 90.035 14.00 81.0


ND315L 508 508 - 216 110 610 230 740 170 140 25.00 M24×50 420 645 1375 865 35
314.0 28.0 90.013 24.948 13.91 80.8

L
FRAME D TOLERANCE E ED F TOLERANCE GD TOLERANCE G
S M L
ND225 55.030 / 55.011 110 80 16.0 / 15.957 10.0 / 9.91 49.0 / 48.8 810 810 –
ABOVE 200 FRAMES
MACHINES RUNNING ND250 60.030 / 60.011 140 110 18.0 / 17.957 11.0 / 10.91 53.0 / 52.8 930 930 –
AT 3000 RPM HAVE ND280 1075 1075 –
SMALLER SHAFTS 65.030 / 65.011 140 110 18.0 / 17.957 11.0 / 10.91 58.0 / 57.8
AS SHOWN HERE ND315 1170 1170 –
ND315L 70.030 / 70.011 140 110 20.0 / 19.948 12.0 / 11.91 62.5 / 62.3 – – 1345

Terminals Box position for ND280S/M is approximately at centre. For notes, please refer page 23, except that cable entry cannot be from
non-driving end.

24
TEFC
SQUIRREL CAGE
MOTORS

DIMENSIONS OF FLANGE MOUNTING MOTORS


IN FRAME ND160 TO ND315

AUXILIARY TERMINAL BOX FOR SPACE HEATER/THERMISTORS ABOVE 200 FRAME ONLY CABLE ENTRY SCREWED
FOR 'KK' CONDUIT
4 - HOLES FOR FRAME 160 - 200 EYEBOLT FOR VERTICALLY
8 - HOLES FOR FRAME 225 - 315 MOUNTED MOTORS ABOVE 200 FRAME ONLY
DRILLED Ø 'S' ON 'M' P.C.D.
CONCENTRICITY
EQUALLY SPACED AS SHOWN L±5
AD LB

N9 / h9 F
GD
+ 0.0
°
45 - 0.5
ED

Ø N SPIGOT
22.5

Ø AC
ØP
G
(E)
HB

ØD

+0
'PERPENDICULARITY E +2
LA

'Y' - THREADED CENTRE HOLE


Y × Depth EARTHING TERMINALS OF M8 SIZE ON BOTH SIDES AND
M12 FOR 280 - 315 FRAME

FLANGE FIXING SHAFT & KEY OVERALL (MAX.)


FRAME
D TOL. N TOL. P S S LA D TOL E ED F TOL. GD TOL. G Y×Depth AD AC L LB HB KK

2 Nos.-1"
ND160MD 42.018 12.00 8.00 37.0 640 213
18 110 80 265 318 432
ND160LD 300.5 250.016 42.002 11.957 7.91 36.8 685 235
350 19 5 M16×32
299.5 249.987 48.018 14.00 9.00 42.5
ND180MD 708 241.5
18 110 80 285 352 476
ND180LD 48.002 13.957 8.91 42.3 746 260.5
350.5 300.018 55.030 16.00 10.00 49.0
ND200LD 400 19 5 18 110 80 345 405 810 285.5 528
349.5 299.982 55.011 15.957 9.91 48.8
M20×40

2 Nos.-1.5"
ND225SD 400.5 350.018 60.030 18.00 11.00 53.0
450 19 5 19 140 110 375 448 855 304.5 590
ND225MD 399.5 349.982 60.011 17.957 10.91 52.8

ND250SD 65.030 18.00 11.00 58.0


140 110 405 486 975 342.5 688
ND250MD 500.5 450.020 65.011 17.957 10.91 57.8
550 19 5 22 M20×40
ND280SD 499.5 449.980 20.00 12.00 67.5
75.030 430 540 1120 399.5 725
140 110
ND280MD 75.011 19.948 11.91 67.3

ND315SD 80.030 22.00 14.00 71.0


2 Nos.-2"

170 140 M20×40 510 590 1250 444.5 725


601.0 550.022 80.011 21.948 13.91 70.8
ND315MD 600 24 6 25
599.0 549.978 90.035 25.00 14.00 81.0
ND315LD 170 140 M24×50 570 645 1425 530.5 820
90.013 24.948 13.91 80.8

L
FRAME D TOLERANCE E ED F TOLERANCE GD TOLERANCE G
SD MD LD
ND225 55.030 / 55.011 110 80 16.0 / 15.957 10.0 / 9.91 49.0 / 49.8 855 855 –
ABOVE 200 FRAMES
MACHINES RUNNING ND250 60.030 / 60.011 140 110 18.0 / 17.957 11.0 / 10.91 53.0 / 52.8 975 975 –
AT 3000 RPM HAVE ND280 1120 1120 –
SMALLER SHAFTS 65.030 / 65.011 140 110 18.0 / 17.957 11.0 / 10.91 58.0 / 57.8
AS SHOWN HERE ND315 122 122 –
ND315 70.030 / 70.011 140 110 20.0 / 19.948 12.0 / 11.91 62.5 / 62.3 – – 1395

CONCENTRICITY IN MICRONS PERPENDICULARITY IN MICRONS RUNOUT IN MICRONS


FRAME
NORM. NORM. SHAFT Ø NORM.
30-50 50
160-280 125 125
50-80 60
315 160 160 90 70
For notes, please refer page 23.

25
TEFC
SQUIRREL CAGE
MOTORS

DIMENSIONS OF FOOT CUM FLANGE MOUNTING MOTORS


IN FRAME ND160 TO ND315

CABLE DIVIDING BOX PROVIDED


4-HOLES FOR FRAME 160-200 AUXILIARY TERMINAL BOX FOR SPACE HEATER/
FOR ND200 ONWARDS
8- HOLES FOR FRAME 225-315 THERMISTOR ABOVE 200 FRAME ONLY
CONCENTRICITY
DRILLED 'S' ON 'M' P.C.D. L±5 AC
EQUALLY SPACED AS SHOWN LB AD
T
22°30° 45° LA

N9 / H9
GD

+0.0
F ED-0.5

HD
N SPIGOT
ØP
G

(E)

H
ØD

+0
E +2 C ±1 B ± 0.5 BA HA AA A ±0.5
Y-THREADED CENTRE B' ± 0.5 AB
PERPENDICULARITY BB
Y × DEPTH
CABLE ENTRY SCREWED FOR 'KK' B.S. CONDUIT 4-HOLES "K" DIA.

EARTHING TERMINALS OF M8 SIZE ON BOTH SIDES


AND M12 FOR 280 AND 315 FRAME
ALL DIMENSIONS ARE IN MM

FOOT FIXING FLANGE FIXING SHAFT AND KEY


FRAME
A B B' C H TOL AA AB BA BB K TOL M TOL N TOL P S LA T D TOL E ED F TOL GD TOL G Y×Depth
ND160MH C0 - 160.0 254 15.5 42.018 12.00 8.00 37.0
254 108 73 308 76 110 80 11.957
ND160LH 254 - 159.7 298 15.0 42.002 7.91 36.8
300.5 250.016
M16×32
ND180MH 241 - 286 15.5 299.5 249.987 350 19 18 5
180.0 48.018 14.00 9.00 42.5
279 121 179.7 84 348 95
ND180LH 279 - 323
15.0 42.002 110 80 13.957 8.91 42.3
200.0 64 381 104 19.5 350.5 300.018 55.030 16.00 10.00 49.0
ND200LH 318 305 - 133 356 400 19 18 5
199.5 19.0 349.5 299.982 55.011 110 80 15.957 9.91 48.8
ND225SH 286 -
356 149 225.0 70 425 102 375 19.5 400.5 350.018 60.030
140 110
18.00 11.00 53.0
ND225MH - 311 224.5 19.0 399.5 349.982 450 19 19 5 60.011 17.957 10.91 53.8

ND250SH 311 - 250.0 24.5 65.030 18.00 11.00 58.0


406 168 80 483 135 419 140 110 M20×40
ND250MH - 349 249.5 24.0 500.5 450.020 65.011 17.957 10.91 57.8
550 19 22 5
499.5 449.980
ND280SH 368 - 280.0 24.5 75.030 20.00 12.00 67.5
457 190 100 538 198 487
ND280MH - 419 279.0 24.0 75.011 140 110 19.948 11.91 67.3

ND315SH 406 - 315.0 28.5 80.030 22.00 14.00 71.0


508 216 110 597 164 533 170 140
ND315MH - 457 314.0 28.0 601.0 550.022 80.011 21.948 13.91 70.8
599.0 549.978 660 24 25 6 90.035 25.00 14.00 81.0
ND315LH 508 508 - 216 315.0 110 610 230 740 28.5 170 140 M24×50
314.0 28.0 90.013 24.948 13.91 80.8
(Continued on the next page)

26
TEFC
SQUIRREL CAGE
MOTORS

OVERALL D F GD
FRAME FRAME E ED G Y
TOLERANCE TOLERANCE TOLERANCE
AD AC L LB HD HA KK
ND225SH 55.030 16.00 10.0 49.0
ND160MH 605 213 110 80 810
265 318 376 22 ND225MH 55.011 15.957 9.91 48.8

2Nos.-1"
ND160LH 650 235
ABOVE 200 FRAMES ND250SH
ND180MH 668 241.5 60.030 18.00 11.00 53.0 930
MACHINES RUNNING 140 110
285 352 418 22 ND250MH 60.011 17.957 10.91 52.3 930
ND180LH 706 260.5 AT 3000 RPM HAVE
ND280SH 65.030 18.00 11.00 58.0
ND200LH 345 405 775 285.5 464 25 SMALLER SHAFTS 140 110 1075
ND280MH 65.011 17.957 10.91 57.8
AS SHOWN HERE
ND225SH
375 448 840 304.5 520 25 ND315SH 53.0 1170
2Nos.-1.5"

65.030 18.00 11.00


ND225MH 140 110
ND315MH 65.011 17.957 10.91 53.8 1170
ND250SH
405 486 930 342.5 624 32 ND315LH 70.030 20.00 12.00 62.5
ND250MH 70.011
140 110
19.948 11.91 62.3 1345
ND280SH
430 540 1075 399.5 642 35 FRAME CONCENTRICITY PERPENDICULARITY RUNOUT
ND280MH
IN MICRON IN MICRON IN MICRON
ND315SH
2Nos.-2"

510 590 1200 444.5 725 38 NORM NORM. SHAFT Ø NORM.


ND315MH
30-50 50
160-280 63 125
ND315LH 570 645 1375 530.5 755 35 50-80 60
315 80 160 90 70

1. All dimensions are in mm, unless specified.


2. Cable entries can be rotated through 360° in
steps of 90°.
3. One cable entry for DOL starting and two for
star / delta starting and multispeed motors are
provided.
4. Compression type cable glands can be fitted
when specified.
5. All dimensions are subject to confirmation.
Certified Drawings will be sent on request.

27
TEFC
SLIP RING
MOTORS

APPLICATION sets, giving rigidity at all working temperatures.


Motors have a high insulation resistance and
Besides other applications like re-rolling mills, a high resistance to moisture, saline
the main feature of this range is the variety of atmosphere, acidic/alkaline fumes, oil and
CRANE DUTY motors, designed for service on grease. They offer complete reliability under
cranes and hoists. Exclusively made to meet all working conditions including humid tropical
stringent starting duty requirements of this climates. The end-turns of the rotor windings
application, motors have unique torque-speed have tensile bands to hold them in place
characteristics for rapid acceleration, with against the centrifugal force caused by
minimum heat losses in the rotor circuit. overspeed.
These motors are robust in construction and
extremely sound in electrical and mechanical BEARINGS AND SHAFTS
design. They are made suitable for frequent
Ball and roller bearings are used. Grease
switching and reversals.
nipples are provided on both sides to facilitate
Crompton Greaves TEFC Slip Ring Motors preventive maintenance without dismantling
comply with IEC and other international the motor. Shafts are machined to extremely
standards. fine limits to ensure fit and interchangeability
of bearings.
ENCLOSURE
For all Slip Ring Motors made in Totally BRUSHGEAR AND SLIPRINGS
Enclosed Fan Cooled (TEFC) enclosure, the The sliprings and brushgear are simple to
degree of protection for a standard motor is assemble. They are enclosed by a cover held
IP55 as per IEC. in place against a grommet in a groove in the
endshield, by means of studs and wingnuts to
INSULATION allow easy access for maintenance. However,
All motors are supplied with Class 'F' insulation motors in DW132 frame size have brushgear
both for stator and rotor. Yet temperature rise and sliprings inside the motor housing, which
by resistance method is limited to Class B also provides easy access for maintenence.
limits. As sliprings are continuously rated, a short
circuiting handle is not required.
COOLING AND VENTILATION In all frames, the sliprings are of the moulded
An external fan is mounted directly on the type which gives stability and a high degree of
shaft which blows air on the ribbed surface of anti-tracking, besides being easy to clean.
the motor. The fan is covered by a fan cover.
TERMINALS AND CABLE ARRANGEMENTS
OVERSPEED Terminals are mounted on a moulded base
All motors are capable of withstanding and enclosed in a box having an inspection
minimum 2.5 times the rated speed subject to cover. Terminal boxes are suitable for British
a maximum of 2000 RPM as stipulated in IEC. Standard screwed conduits. Standard
compression type cable glands, suitable for
OVERLOAD CAPACITY PVC-A-PVC cable, can be fitted on request.
All motors can withstand 60% overload for 15 Rotor and stator leads are terminated in the
seconds as given in the IEC standards. same terminal box, which facilitates easy
connections. The standard position of the
CORES stator terminal box is on the left hand side
(when looking from the non-driving end of the
Both stator and rotor cores consist of high
motor). This can also be arranged on the right
quality magnetic steel stampings.
hand side, if specified in the order.
WINDINGS AND INSULATION Motors in frame NDW160 and above can also
be supplied with terminal box on top if
Stator and rotor windings consist of synthetic
specified in the order
enamel-covered copper wire or strip with slot
insulation, complying with IEC norms. CRANE DUTY SLIPRING MOTORS
All windings are impregnated with a synthetic
resin varnish and then baked in special Crane duty TEFC slipring motors are available
heat-regulated ovens at a correct from frame 132 upwards to cover various duty
temperature. The varnish polymerises and factors and starts/stops per hour.

28
TEFC
SLIP RING
MOTORS

PERFORMANCE DATA
Supply : 415V or 380V, 50 Hz, 3 Phase AC Voltage Variation : ± 10%
Enclosure : Totally Enclosed Fan Cooled (TEFC) Frequency Variation : ± 5%
Degree of Protection : IP55 Combined Variation : ± 10%
Rating: Continuous, Duty : S1 Mounting : B3, Ambient : 45° C
Insulation Class : ‘F’ Temperature Rise by Resistance Method : 75°C Max.
P
OUTPUT FL FL EFFICIENCY (%) POWER FACTOR OPEN CIRCUIT ROTOR NETT
O FL GD²
FRAME AMPS AMPS ROTOR VOLTAGE CURRENT WEIGHT
L RPM 3/4 1/2 3/4 1/2 KgM²
kW HP 380 V 415 V FL FL VOLTS AMPS Kg.
E FL FL FL FL
1.5 2.0 8 DW132S 680 4.5 70.0 67.0 63.0 0.61 0.51 0.40 110 8.5 0.33 88

2.2 3.0 4 DW132S 1410 4.5 78.0 76.0 74.0 0.85 0.79 0.71 110 13.5 0.17 88
2.2 3.0 6 DW132S 940 6.0 77.0 75.0 71.0 0.72 0.62 0.50 110 12.0 0.33 88
2.2 3.0 8 DW132M 690 5.7 75.0 74.0 71.0 0.65 0.55 0.44 110 13.0 0.40 111

3.0 4.0 4 DW132S 1410 6.0 80.0 78.0 74.0 0.80 0.74 0.66 110 17.0 0.17 88
3.0 4.0 6 DW132M 940 7.6 79.0 78.0 75.0 0.69 0.64 0.53 110 16.0 0.40 111
3.0 4.0 8 NDW160M 690 8.5 7.5 80.0 79.0 77.0 0.68 0.64 0.56 230 8.0 0.58 132

3.7 5.0 4 DW132S 1400 8.0 79.0 78.0 75.0 0.84 0.79 0.70 110 23.0 0.17 88
3.7 5.0 6 DW132M 930 9.0 81.0 80.0 77.0 0.70 0.62 0.50 110 18.0 0.40 111
3.7 5.0 8 NDW160M 710 10.5 10.0 81.0 80.0 78.0 0.68 0.64 0.56 230 10.0 0.58 141

5.5 7.5 4 DW132M 1430 12.0 81.0 78.0 74.0 0.80 0.72 0.62 110 33.0 0.20 111
5.5 7.5 6 NDW160M 940 13.5 12.0 83.0 82.0 80.0 0.76 0.74 0.66 180 18.5 0.58 141
5.5 7.5 8 NDW160L 710 15.0 14.0 82.0 81.0 79.0 0.68 0.64 0.56 360 10.0 0.80 165

7.5 10.0 4 NDW160M 1440 16.5 15.0 83.0 82.0 80.0 0.84 0.80 0.72 350 13.0 0.48 141
7.5 10.0 6 NDW160L 940 18.0 16.5 83.0 82.0 80.0 0.76 0.72 0.64 260 19.0 0.77 165
7.5 10.0 8 NDW180L 710 20.0 18.0 84.0 83.0 81.0 0.68 0.64 0.56 350 13.0 1.58 235

9.3 12.5 4 NDW160L 1440 20.0 18.0 84.0 83.0 81.0 0.84 0.80 0.72 350 16.0 0.35 165
9.3 12.5 6 NDW180M 950 20.0 18.0 86.0 85.0 83.0 0.82 0.78 0.70 230 24.0 1.33 205
9.3 12.5 8 NDW200L 725 24.5 22.0 86.0 85.0 83.0 0.68 0.64 0.76 300 19.5 2.68 285

11.0 15.0 4 NDW160L 1440 24.0 22.0 84.0 83.0 81.0 0.84 0.80 0.72 350 19.0 0.35 165
11.0 15.0 6 NDW180L 950 24.0 22.0 86.0 85.0 83.0 0.82 0.78 0.70 230 28.5 1.58 235
11.0 15.0 8 NDW200L 725 28.0 26.0 87.0 86.0 84.0 0.68 0.64 0.56 300 23.0 2.68 285

15.0 20.0 4 NDW180L 1445 31.0 28.0 88.0 87.0 85.0 0.84 0.80 0.72 350 27.0 1.25 235
15.0 20.0 6 NDW200L 970 31.0 28.5 89.0 88.0 86.0 0.82 0.78 0.70 295 31.0 2.68 285
15.0 20.0 8 NDW225M 730 37.5 34.0 87.0 86.0 84.0 0.70 0.66 0.58 350 27.0 3.06 410

18.5 25.0 4 NDW200L 1470 38.0 34.0 89.0 88.0 86.0 0.84 0.80 0.72 300 36.0 2.18 285
18.5 25.0 6 NDW225M 970 38.5 36.0 89.0 88.0 86.0 0.82 0.78 0.70 310 37.0 2.87 410
18.5 25.0 8 NDW225M 730 46.0 42.0 88.0 87.0 85.0 0.70 0.66 0.58 360 32.0 3.63 410

22.0 30.0 4 NDW200L 1470 44.5 40.0 89.0 88.0 86.0 0.85 0.81 0.73 390 33.0 2.34 285
22.0 30.0 6 NDW225M 970 46.0 42.0 89.0 88.0 86.0 0.82 0.78 0.70 310 45.0 3.25 410
22.0 30.0 8 NDW250M 730 50.0 45.0 91.0 90.0 88.0 0.74 0.70 0.62 250 55.0 6.81 540

30.0 40.0 4 NDW225M 1470 60.0 55.0 89.0 88.0 86.0 0.85 0.81 0.73 380 47.0 2.96 410
30.0 40.0 6 NDW250M 975 61.0 55.0 91.0 90.0 88.0 0.82 0.78 0.70 320 56.0 6.81 540
30.0 40.0 8 NDW280S 735 68.0 62.0 91.0 90.0 88.0 0.74 0.70 0.62 440 43.0 12.89 670

37.0 50.0 4 NDW250M 1475 73.0 67.0 90.0 89.0 87.0 0.85 0.81 0.73 425 52.0 4.96 540
37.0 50.0 6 NDW280S 980 74.0 67.0 91.0 90.0 88.0 0.84 0.80 0.72 410 57.0 12.89 670
37.0 50.0 8 NDW280M 735 83.0 76.0 91.0 90.0 88.0 0.74 0.70 0.62 520 45.0 15.14 750

45.0 60.0 4 NDW250M 1475 89.0 82.0 90.0 89.0 87.0 0.85 0.81 0.73 445 60.0 5.70 540
45.0 60.0 6 NDW280M 980 88.0 81.0 91.5 91.0 89.0 0.85 0.81 0.73 320 87.0 15.14 750
45.0 60.0 8 NDW315S 735 102.0 93.0 91.0 90.0 88.0 0.74 0.70 0.62 320 88.0 21.66 1106

55.0 75.0 4 NDW280S 1480 106.0 97.0 91.5 91.0 89.0 0.86 0.82 0.74 460 73.0 10.61 670
55.0 75.0 6 NDW315S 980 107.0 98.0 92.0 91.0 89.0 0.85 0.81 0.73 535 62.0 22.00 1106
55.0 75.0 8 NDW315M 735 122.0 112.0 91.0 90.0 88.0 0.75 0.71 0.63 320 108.0 24.16 1180

75.0 100.0 4 NDW280M 1480 142.0 130.0 92.5 92.0 90.0 0.87 0.83 0.75 490 92.0 12.45 750
75.0 100.0 6 NDW315M 980 144.0 132.0 93.0 92.0 90.0 0.85 0.81 0.73 470 96.0 24.16 1180
75.0 100.0 8 NDW315L 740 150.0 138.0 92.5 92.0 90.0 0.82 0.78 0.70 400 113.0 36.73 1260

29
TEFC
SLIP RING
MOTORS

PERFORMANCE DATA (Continued)


P
OUTPUT FL FL EFFICIENCY (%) POWER FACTOR OPEN CIRCUIT ROTOR NETT
O FL GD²
FRAME AMPS AMPS ROTOR VOLTAGE CURRENT WEIGHT
L RPM 3/4 1/2 3/4 1/2 KgM²
380 V 415 V FL FL VOLTS AMPS Kg.
kW HP E FL FL FL FL
90.0 120.0 4 NDW315S 1480 172.0 159.0 92.5 92.0 90.0 0.86 0.82 0.74 505 106.0 18.22 1106
90.0 120.0 6 NDW315L 980 171.0 157.0 93.0 92.0 90.0 0.86 0.82 0.74 400 135.0 36.73 1260
90.0 120.0 8 NDW315L 740 180.0 165.0 92.5 92.0 90.0 0.82 0.78 0.70 400 135.0 36.73 1260
110.0 150.0 4 NDW315M 1485 210.0 193.0 92.5 92.0 90.0 0.86 0.82 0.74 500 169.0 20.21 1180
110.0 150.0 6 NDW315L 980 209.0 192.0 93.0 92.0 90.0 0.86 0.82 0.74 400 169.0 40.00 1260
125.0 168.0 4 NDW315L 1485 232.0 213.0 93.0 92.0 90.0 0.88 0.84 0.76 400 190.0 30.60 1260
125.0 168.0 6 NDW315L 980 237.0 218.0 93.0 93.0 90.0 0.86 0.82 0.74 400 190.0 40.00 1260
150.0 200.0 4 NDW315L 1485 277.0 254.0 93.5 92.5 90.0 0.88 0.84 0.76 400 225.0 33.45 1260
160.0 215.0 4 NDW315L 1485 295.0 271.0 93.5 92.5 90.0 0.88 0.84 0.76 400 242.0 33.45 1260
The above data is subject to tolerance as per the
applicable standard.
FL - Full Load, STG - Starting, C - Current,
T - Torque, DOL - Direct on Line, S/D-Star/Delta

30
TEFC
SLIP RING
MOTORS

SHIPPING SPECIFICATIONS
FOOT MOUNTED MOTORS,
TERMINAL BOX ON SIDE
NETT WEIGHT GROSS WEIGHT DIMENSIONS VOLUME
FRAME
KG KG L IN MM B IN MM H IN MM CUBIC METRES
DW132S 88 126 815 550 485 0.22
DW132M 111 149 815 550 485 0.22
NDW160M 141 243 1165 710 700 0.58
NDW160L 165 267 1165 710 700 0.58
NDW180M 205 311 1025 825 700 0.59
NDW180L 235 341 1025 825 700 0.59
NDW200L 285 423 1300 915 745 0.89
NDW225S 380 518 1300 915 745 0.89
NDW225M 410 548 1300 915 745 0.89
NDW250S 500 638 1300 915 745 0.89
NDW250M 540 678 1300 915 745 0.89
NDW280S 670 884 1500 1065 850 1.36
NDW280M 750 964 1500 1065 850 1.36
NDW315S 1106 1359 1600 1170 925 1.73
NDW315M 1180 1433 1600 1170 925 1.73
NDW315L 1260 1613 1830 1270 1156 2.69

FOOT MOUNTED MOTORS,


TERMINAL BOX ON TOP
NETT WEIGHT GROSS WEIGHT DIMENSIONS VOLUME
FRAME
KG KG L IN MM B IN MM H IN MM CUBIC METRES
NDW160M 141 243 1165 710 700 0.58
NDW160L 165 267 1165 710 700 0.58
NDW180M 205 307 1165 710 700 0.58
NDW180L 235 337 1165 710 700 0.58
NDW200L 285 393 1275 725 790 0.73
NDW225S 380 488 1275 725 790 0.73
NDW225M 410 518 1275 725 790 0.73
NDW250S 500 633 1450 785 890 1.01
NDW250M 540 673 1450 785 890 1.01
NDW280S 670 803 1450 785 890 1.01
NDW280M 750 883 1450 785 890 1.01
NDW315S 1106 1346 1730 920 1065 1.70
NDW315M 1180 1420 1730 920 1065 1.70
NDW315L 1260 1530 1830 1000 1115 2.04
The standard packing is wooden for all above
motors.

31
TEFC
SLIP RING
MOTORS

DIMENSIONS OF FOOT MOUNTING MOTORS


IN FRAME DW132

L E
Ø AC
SLIPRING MAINTAINANCE
COVER AT OPPOSITE
ENDS AD
TAPPED HOLE
Y × DEPTH ED ED

GE
N9/h9
F

HD
D HC

D D H

G GD

GA BA HA
AA 4 HOLES K DIA
2-CABLE ENTRIES
SCREWED FOR KK BS
E C B CONDUIT FOR CABLE A
GLAND

BB AB

FOOT FIXING SHAFT AND KEY OVERALL (MAX.)


FRAME
A B C H AA AB BA BB K HA D E ED F G GA GD GE Y×Depth AD AC L HC HD KK

DW132S 140 178 600


216 89 132 41 254 64 12 16 38 80 60 10 33 41 8 5 M12×28 255 320 290 350 1"
DW132M 178 216 640

TOLERANCE
ON GRADE RANGE TOLERANCE ON GRADE RANGE TOLERANCE
CENTRE HEIGHT KEYWAY
+ 0.0
H – ALL + 0.0
– 0.5 F N9 8 TO 10
– 0.036
SHAFT

+ 0.3
+ 0.018 ED – 32 TO 80 – 0.0
D k6 32 TO 48 + 0.002
KEY
+ 0.2
GE – 4 & ABOVE – 0.0 + 0.0
F h9 8 TO 10
– 0.036
1. All dimensions are in mm, unless specified.
2. Cable entries can be rotated through 360° in
steps of 90°. h11 + 0.0
GD 7 TO 10
3. Compression type cable glands can be fitted – 0.090
when specified.
4. All dimensions are subject to confirmation.
Certified Drawings will be sent on request.

32
TEFC
SLIP RING
MOTORS

DIMENSIONS OF FLANGE MOUNTING MOTORS


IN FRAME DW132

L E
AD
R
E LB
TAPPED HOLE 45 ED
°
Y × DEPTH
ED
GE
N9/h9
HB
F

N DIA.
D Ø AC
SPIGOT
D D

G GD
P Ø
SLIPRING MAINTAINANCE
GA T
2 - CABLE ENTRIES SCREWED COVER AT OPPOSITE ENDS.
4 - HOLES DRILLED FOR 25.4 MM (1") BS CONDUIT LA
S DIA. ON M DIA. CIRCLE. FOR CABLE GLAND

FLANGE FIXING SHAFT AND KEY OVERALL (MAX.)


FRAME
M N P R S T LA D E ED F G GA GD GE Y×Depth AD L LB AC HB

DW132SD 600 520


300 230 350 0 15 4 13 38 80 60 10 33 41 8 5 M12×28 255 320 220
DW132MD 640 560

TOLERANCE

ON GRADE RANGE TOLERANCE ON GRADE RANGE TOLERANCE


PCD KEYWAY

M – UP TO 265 ± 0.3 + 0.0


F N9 8 TO 10
– 0.036
SPIGOT

+ 0.016 + 0.3
N j6 180 TO 250 ED – 32 TO 80
– 0.013 – 0.0

SHAFT KEY

F h9 8 TO 10 + 0.0
k6 + 0.018
D 32 TO 48 – 0.030
+ 0.002

+ 0.2 GD h11 7 TO 10 + 0.0


GE – 4 & ABOVE – 0.090
- 0.0

1. All dimensions are in mm, unless specified.


2. Cable entries can be rotated through 360° in
steps of 90°.
3. Compression type cable glands can be fitted
when specified.
4. All dimensions are subject to confirmation.
Certified Drawings will be sent on request.

33
TEFC
SLIP RING
MOTORS

DIMENSIONS OF FACE MOUNTING MOTORS


IN FRAME DW132

AD L
R
LB E
E
45°
ED ED
TAPPED HOLE
GE
Y × DEPTH
HB
N9 / h9
F

Ø N
D Ø AC
SPIGOT
D
D

G GD

GA
4 HOLES TAPPED P 2 CABLE ENTRIES T
S Ø ×'LA' DEEP SCREWED FOR SLIPRING
MAINTAINANCE
EQUALLY SPACED 25.4(1") BS CONDUIT COVER AT OPPOSITE
ON M DIA CIRCLE FOR CABLE GLAND SIDES

FLANGE FIXING SHAFT AND KEY OVERALL (MAX.)


FRAME
M N P R S T LA D E ED F G GA GD GE Y×Depth AD L LB AC HB

DW132SC 600 520


165 130 200 0 M10 3.5 13 38 80 60 10 33 41 8 5 M12 × 28 255 320 220
DW132MC 640 560

TOLERANCE

ON GRADE RANGE TOLERANCE ON GRADE RANGE TOLERANCE


PCD KEYWAY

M – UP TO 265 ± 0.3 + 0.0


F N9 8 TO 10
– 0.036
SPIGOT

+ 0.014 + 0.3
N j6 120 TO 180 ED – 32 TO 80
– 0.009 – 0.0

SHAFT KEY

F h9 8 TO 10 + 0.0
k6 + 0.018
D 32 TO 48 – 0.036
+ 0.002

+ 0.2 GD h11 7 TO 10 + 0.0


GE – 4 & ABOVE – 0.090
– 0.0

1. All dimensions are in mm, unless specified.


2. Cable entries can be rotated through 360° in
steps of 90°.
3. Compression type cable glands can be fitted
when specified.
4. All dimensions are subject to confirmation.
Certified Drawings will be sent on request.

34
TEFC
SLIPRING
MOTORS

DIMENSIONS OF FLANGE MOUNTED MOTORS


IN FRAMES DW160 TO DW180

L E
AD
R
E LB
TAPPED HOLE 45 ED
°
Y × DEPTH
ED
GE
N9/h9
HB
F

N DIA.
D Ø AC
SPIGOT
D D

G GD
P Ø
SLIPRING MAINTAINANCE
GA T
2 - CABLE ENTRIES SCREWED COVER AT OPPOSITE ENDS.
4 - HOLES DRILLED FOR 25.4 MM (1") BS CONDUIT LA
S DIA. ON M DIA. CIRCLE. FOR CABLE GLAND

FLANGE FIXING SHAFT AND KEY OVERALL (MAX.)


FRAME
M N LIMITS P R S T LA N LIMITS E ED F LIMITS GA AD L LB AD AD

DW160MD + 0.016 37.0 704 554


300 250 350 0 19 5 19 42 110 80 12 45 295 360 230
DW160LD

DW180MD
300 250
– 0.013

+ 0.016
350 0 19 5 19 48
} + 0.013
– 0.002
110 80 14
36.7

42.5
51.5 315
748 638

768 658
415 260
DW180LD – 0.013 42.3 806 696

1. All dimensions are in mm, unless specified.


2. Cable entries can be rotated through 360° in
steps of 90°.
3. Compression type cable glands can be fitted
when specified.
4. All dimensions are subject to confirmation.
Certified Drawings will be sent on request.

35
TEFC
SLIP RING
MOTORS

DIMENSIONS OF FOOT MOUNTING MOTORS


IN FRAMES NDW160 TO NDW315 WITH TERMINAL BOX ON SIDE

CABLE DIVIDING BOX PROVIDED AUXILIAR Y TERMINALS BOX FOR


FOR ND 200 ONWARDS SLIPPRING ACCES S FROM TOP
FOR ND & FOR DW250 & DW315 SPACE HE ATER & THERMISTERS
ACCESS FROM BOTH SIDES ABOVE 200 FRAME ONLY
L±5
AC
'Y' THREADED L AD
CENTRE HOLE

+0.0 +0.0
N9/h9 -0.5 -0.5
ED ED
F
A

HD
D

H
h

GA
E C B±0.3 BA AA
E HA
SEC. A - A B'±0.3 A±0.5
BB AB
CABLE ENT RY SCREWED
DOUBLE SHAF T EXTN. WHEN READ FOR 'KK' B.S.CONDUIT
4-HOLES 'K' DIA.
EA RTHING TERMINALS OF M8 SIZE
ON BOTH SIDES . THESE SHAL L BE
M12 FOR 280 AND ABOVE

FOOT FIXING SHAFT & KEY OVERALL (MAX.)


FRAME
A B B' C H AA AB BA BB K TOL. D TOL. E ED F×h GA Y×Depth AD AC L L1 HD HA KK
NDW160M 210 - 254 15.5 42.018
254 108 160.0 73 308 76 12×8 45.0
265 318
766 882
376 22

2Nos.-1"
NDW160L 254 - 159.7 298 15.0 42.002 44.8 810 926
M16×32
NDW180M 241 - 180.0 286 15.5 48.018 51.5 840 956
279 121 84 348 95 110 80 14×9 285 352 418 22
NDW180L 279 - 179.7 323 15.0 48.002 51.3 878 994
200.0 19.5 55.030 49.0
NDW200L 318 305 - 133 199.5 64 381 104 356 16×10 345 405 952 1068 464 25
19.0 55.011 58.0
NDW225S 286 -
356 149 225.0 70 425 102 375 19.5 60.030 18×11 64.0 375 448 1072 1218 520 25
2Nos.-1.5"
NDW225M - 311 224.5 19.0 60.011 63.8
DW250S 311 - 381 24.5 65.030
406 168 250.0 79 483 127 140 110 18×11
69.0
M20×40 425 540
1054 1200
624 32
DW250M 349 - 249.5 419 24.0 65.011 68.8 1092 1238
NDW280S 368 - 280.0 24.5 75.030 79.5
457 190 100 538 198 487 20×12 430 540 1265 1415 642 35
NDW280M - 419 279.0 24.0 75.011 79.3

DW315S 406 - 315.0 482 28.5 80.030 85.0 1294 1472


508 216 89 597 153 22×14 537 700 725 38
2Nos.-2"

DW315M - 457 314.0 533 28.0 80.011 84.8 1345 1523


170 140
NDW315L 508 508 - 216 315.0 110 610 230 740 28.5 90.035
25×14
95.0 M24×50 570
645 1565 1740 755 35
314.0 28.0 90.013 94.8

1. All dimensions are in mm, Unless specified.


2. Stator and endshields shall be with fins
although there are not shown in detail.
3. Cable entries can be rotated through 270° in
steps of 90° for all positions except driving end.
4. Terminal Box position for frame ND290S/M shall
be approximately at centre
5 Compression type cable glands can be fitted
when specified.
6. All dimensions are subject to confirmation.
Certified Drawings will be sent on request.

36
TEFC
SLIP RING
MOTORS

DIMENSIONS OF FOOT MOUNTING MOTORS


IN FRAMES NDW160 TO NDW315 WITH TERMINAL BOX ON TOP

CABLE ENT RY SCREWED FOR 'KK' B.S.CONDUIT CABLE DIVIDING BOX PROVIDED FOR 200 FRAME ON WARDS

2-EYE BO LTS FOR 200 AN D ABOVE


AUXILIA RY TERMINA L BOX FOR S PACE HE ATER/
THERMISTERS ABOVE 200 FRAME ON LY. AD
'Y' THREADED CENTRE HOLES
SLIPRING ACCES S COVER AC
Y × DEPTH L± 5

N9 / h9
F
GD

+0.0
+0.5
ED

HD
G

H
D

BA HA AA
E ± 0.5 C±1 B ± 0.5
B' ± 0.5 A ± 0.5
4-HOLES 'K' DIA.
BB AB

EA RTHING TERMINALS OF M8 ON BOTH SIDE S AND M12


FOR 280-315 FRAME

FOOT FIXING SHAFT & KEY OVERALL (MAX.)


FRAME
A B B' C H AA AB BA BB K D E ED F GD G Y×Depth AD AC L HD HA KK
NDW160M 210 - 254 15.5 42.018 12.00 8.00 37.0 766
254 108 160.0 73 308 76 110 80 – 318 425 22

2Nos.-1"
NDW160L 254 - 159.7 298 15.0 42.002 11.957 7.91 36.8 810
M16×32
NDW180M 241 - 180.0 286 15.5 48.018 14.00 9.00 42.5 840
279 121 84 348 95 110 80 – 352 465 22
NDW180L 279 - 179.7 323 15.0 48.002 13.957 8.91 42.3 878
200.0 19.5 55.030 16.00 10.00 49.0
NDW200L 318 305 - 133 199.5 64 381 104 356 110 80 285 405 952 545 25
19.0 55.011 15.957 9.91 48.8
NDW225S 286 -
356 149 225.0 70 425 102 375 19.5 60.030 140 110 18.00 11.00 53.0 285 448 1072 600 25
2Nos.-1.5"
NDW225M - 311 224.5 19.0 60.011 17.957 10.91 53.8
M20×40
NDW250S 311 - 24.5 65.030 18.00 11.00 58.0
406 168 250.0 80 483 135 419 140 110 285 486 1128 645 32
NDW250M - 349 249.5 24.0 65.011 17.957 10.91 57.8

NDW280S 368 - 280.0 24.5 75.030 20.00 12.00 67.5


457 190 100 538 198 487 140 110 285 540 1265 700 35
NDW280M - 419 279.0 24.0 75.011 19.948 11.91 67.3

NDW315S 406 - 315.0 28.5 80.030 22.00 14.00 71.0


508 216 110 597 164 533 170 140 21.948 375 590 1460 845 38
2Nos.-2"

NDW315M - 457 314.0 28.0 80.011 13.91 70.8


M24×50
NDW315L 508 508 - 216 315.0 110 610 230 740 28.5 90.035 170 140 25.00 14.00 81.0 420 645 1565 865 32
314.0 28.0 90.013 24.948 13.91 80.8

1. All dimensions are in mm, Unless specified.


2. Stator and endshields shall be with fins
although there are not shown in detail.
3. Cable entries can be rotated through 270° in
steps of 90° for all positions except driving end.
4. Terminal Box position for frame ND290S/M shall
be approximately at centre
5 Compression type cable glands can be fitted
when specified.
6. All dimensions are subject to confirmation.
Certified Drawings will be sent on request.

37
DRIP PROOF
SQUIRREL CAGE
MOTORS

APPLICATION diecast. Motors in frames above 250M have


rotor bars of copper or copper alloy, brazed to
The drip-proof cage motors are the most copper or copper alloy end-rings.
compact, have the simplest construction Rotors are dynamically balanced on
and are the lowest in cost. They are, precision balancing machines, minimizing the
therefore, the most economical drive for vibration level of the motors to less than the
machine tools, pumps, compressors, fans, normal allowable in BS 4999.
conveyors and many other applications in "Precision" balance can also be offered, if
locations where a drip-proof enclosure is required.
considered adequate.
Drip Proof (DP) Motors have ventilated BEARINGS
openings in the end-shields. The openings The motors are provided with ball/roller
are screened to render any accidental bearings. The life of the bearings is minimum
contact with the live or moving parts 20,000 hours. On-line greasing arrangement
impossible. These motors are specially is provided for frame sizes 200 and above.
designed to provide years of continuous
and flawless service. CONNECTIONS
Dimensions and performance are in accordance All motors are provided with stud type terminal
with IEC & other international standards. block.
ENCLOSURE They are also provided with six terminals for
Star-Delta starting.
Generally, motors have IP21 degree of
protection. Motors in frame 225 to 315 have An earthing terminal is provided inside the
IP23 degree of protection. The Terminal Box terminal box.
has IP55 degree of protection as per IEC and ACCESSORIES
other international standards.
Thermistors and/or space heaters (optional)
INSULATION can be provided for all frames on request.
All motors are manufactured with Class F HARDWARE
insulation, with temp. rise restricted to Class
'B' limits. All hardware have metric threads and are zinc
passivated for corrosion resistance.
CONSTRUCTION
INTERCHANGEABILITY AND SPARES
Stator body and end shields are of high
grade cast iron. These are machined to All Crompton Greaves Drip-proof motors
close tolerances for providing perfect are built to standardised designs and
alignment and fits. They are rigid in machined for fine limits. All spare parts are
construction. interchangeable.
Terminal boxes are of cast iron and have TESTS
flanged joints with suitable gaskets between
them. Terminal boxes are provided with All motors are tested in the course of
metric conduit entries. manufacture and before despatch, in
Cast iron fans are provided for all frames. accordance with IEC and other international
The fans are suitable for both directions of standards testing procedure.
rotation except for 2 Pole rating in frames SPECIAL FEATURES
280 to 315. Cast aluminium fans are also
available on request. Special features such as special shafts,
Motors up to Frame 200 have drain holes at motors suitable for dual voltage, high
their lowest position. ambients, high altitudes, multi-speed
operation, duty type rated, quiet running,
ROTOR etc. can be provided to meet the special
requirements of customers. Details are
All rotors upto 250M are aluminium pressure available on request.

38
DRIP PROOF
SQUIRREL CAGE
MOTORS

PERFORMANCE DATA
Supply : 415 V or 380 V, 50 Hz, 3 Phase AC Voltage Variation : ± 10%
Enclosure : Screen Protected, Drip Proof (SPDP) Frequency Variation : ± 5%
Degree of Protection : IP21 for C160 - 200
Combined Variation : ± 10%
IP23 for C225 - 315
Rating : Continuous, Duty: S1 Mounting : B3, Ambient : 45°C
Insulation Class : ‘F’ Temperature Rise by Resistance Method : 75°C Max.
P
OUTPUT FL FL EFFICIENCY (%) POWER FACTOR DOL STG. S/D STG. NETT
O FL GD²
FRAME AMPS AMPS WEIGHT
L RPM 3/4 1/2 3/4 1/2 STG. C STG. T STG. C STG. T KgM²
kW HP 380 V 415 V FL FL Kg.
E FL FL FL FL %FLC %FLT % FLC % FLT
3.7 5.0 8 C160M 700 9.5 9.0 82.0 81.0 79.0 0.74 0.70 0.62 500 200 140 55 0.55 121

5.5 7.5 8 C160M 700 14.0 13.0 82.0 81.0 79.0 0.74 0.70 0.62 500 200 140 55 0.55 121

7.5 10.0 6 C160M 950 17.0 16.0 84.0 83.0 81.0 0.80 0.76 0.68 500 200 140 55 0.42 121
7.5 10.0 8 C160L 700 19.0 17.0 82.0 81.0 79.0 0.74 0.70 0.62 500 200 140 55 0.65 131

9.3 12.5 2 C160M 2900 20.5 19.0 84.0 83.0 81.0 0.82 0.78 0.70 550 200 155 55 0.16 121
9.3 12.5 4 C160M 1450 21.0 19.0 86.0 85.0 83.0 0.78 0.74 0.66 550 200 155 55 0.38 121
9.3 12.5 6 C160L 950 21.0 19.0 84.0 83.0 81.0 0.80 0.76 0.68 500 200 140 55 0.54 131
9.3 12.5 8 C180M 700 21.5 20.0 84.0 83.0 81.0 0.78 0.74 0.66 500 200 140 55 1.14 185

11.0 15.0 2 C160M 2900 24.5 23.0 84.0 83.0 81.0 0.82 0.78 0.70 550 200 155 55 0.16 121
11.0 15.0 4 C160M 1450 24.5 22.0 86.0 85.0 83.0 0.80 0.76 0.68 550 200 155 55 0.38 121
11.0 15.0 6 C160L 950 25.0 23.0 84.0 83.0 81.0 0.80 0.76 0.68 500 200 140 55 0.62 131
11.0 15.0 8 C180M 700 24.5 23.0 85.0 84.0 82.0 0.80 0.76 0.68 500 200 140 55 1.14 185

15.0 20.0 2 C160M 2920 33.0 31.0 84.0 83.0 81.0 0.83 0.79 0.71 550 200 155 55 0.17 121
15.0 20.0 4 C160L 1450 33.0 30.0 87.0 86.0 84.0 0.80 0.76 0.68 550 200 155 55 0.48 131
15.0 20.0 6 C180M 960 33.0 30.0 85.0 84.0 82.0 0.82 0.78 0.70 600 225 170 60 1.14 185
15.0 20.0 8 C180L 700 33.5 31.0 85.0 84.0 82.0 0.80 0.76 0.68 500 200 140 55 1.45 205

18.5 25.0 2 C160L 2920 40.0 39.0 84.0 83.0 81.0 0.84 0.80 0.72 550 200 155 55 0.22 131
18.5 25.0 4 C160L 1450 40.0 36.0 88.0 87.0 85.0 0.80 0.76 0.68 550 200 155 55 0.68 131
18.5 25.0 6 C180L 960 38.0 36.0 87.0 86.0 84.0 0.85 0.81 0.73 600 225 170 60 1.33 205
18.5 25.0 8 C200M 720 44.0 41.0 86.0 85.0 83.0 0.74 0.70 0.62 500 150 140 40 2.20 260

22.0 30.0 2 C160L 2920 45.5 41.0 86.0 85.0 83.0 0.86 0.82 0.74 550 200 155 55 0.28 131
22.0 30.0 4 C180M 1450 45.0 41.0 87.0 86.0 84.0 0.86 0.82 0.74 600 200 170 55 0.91 185
22.0 30.0 6 C200M 960 44.0 40.0 89.0 88.0 86.0 0.86 0.82 0.74 600 200 170 55 1.91 260
22.0 30.0 8 C200L 720 52.0 48.0 87.0 96.0 84.0 0.74 0.70 0.62 500 150 140 40 2.58 300

30.0 40.0 2 C180M 2935 56.0 51.0 89.0 88.0 86.0 0.92 0.88 0.80 600 200 170 55 0.49 185
30.0 40.0 4 C180L 1450 59.0 54.0 88.0 87.0 85.0 0.88 0.84 0.76 600 200 170 55 1.15 205
30.0 40.0 6 C200L 960 59.0 53.0 89.0 88.0 86.0 0.87 0.83 0.75 600 200 170 55 2.58 300
30.0 40.0 8 C225M 720 70.0 64.0 88.0 87.0 85.0 0.74 0.70 0.62 500 150 140 40 3.35 340

37.0 50.0 2 C180L 2945 70.0 65.0 89.0 88.0 86.0 0.90 0.89 0.86 600 225 140 60 0.59 205
37.0 50.0 4 C200M 1455 73.0 68.0 90.0 89.0 87.0 0.85 0.81 0.73 550 225 155 60 1.79 260
37.0 50.0 6 C225M 960 69.0 64.0 92.0 91.0 89.0 0.88 0.84 0.76 600 200 170 55 3.35 340
37.0 50.0 8 C250S 720 79.0 72.0 89.0 88.0 86.0 0.80 0.76 0.68 500 150 140 40 5.38 425

45.0 60.0 2 C200M 2930 84.0 78.0 90.0 89.0 87.0 0.90 0.86 0.78 600 225 170 60 0.78 260
45.0 60.0 4 C200L 1455 86.0 79.0 90.0 89.0 87.0 0.88 0.84 0.76 550 225 155 60 2.11 300
45.0 60.0 6 C250S 970 86.0 79.0 92.0 91.0 89.0 0.86 0.82 0.74 600 200 170 55 5.39 425
45.0 60.0 8 C250M 725 95.0 88.0 89.5 89.0 87.0 0.80 0.76 0.68 500 150 140 40 6.66 480

55.0 75.0 2 C200L 2950 104.0 96.0 89.0 88.0 86.0 0.90 0.86 0.78 650 225 185 60 1.09 300
55.0 75.0 4 C225M 1460 108.0 99.0 90.0 89.0 87.0 0.86 0.82 0.74 600 225 170 60 2.73 340
55.0 75.0 6 C250M 970 103.0 96.0 92.0 91.0 89.0 0.88 0.84 0.76 600 200 170 55 6.66 480
55.0 75.0 8 C280S 730 131.0 120.0 91.0 90.0 88.0 0.70 0.66 0.60 500 200 140 55 10.10 620

75.0 100.0 2 C225M 2930 141.0 130.0 90.0 89.0 87.0 0.90 0.86 0.78 600 200 170 55 1.17 340
75.0 100.0 4 C250S 1475 145.0 133.0 92.5 92.0 90.0 0.85 0.81 0.73 550 175 155 50 4.51 425
93.0 125.0 2 C250S 2950 174.0 155.0 90.0 89.0 87.0 0.90 0.86 0.78 600 200 170 55 1.87 425
93.0 125.0 4 C250M 1475 180.0 163.0 92.5 92.0 90.0 0.85 0.81 0.73 550 175 155 50 5.60 480

39
DRIP PROOF
SQUIRREL CAGE
MOTORS

PERFORMANCE DATA (Continued)


P
OUTPUT FL FL EFFICIENCY (%) POWER FACTOR DOL STG. S/D STG. NETT
O FL GD²
FRAME AMPS AMPS WEIGHT
L RPM 3/4 1/2 3/4 1/2 STG. C STG. T STG. C STG. T KgM²
kW HP 380 V 415 V FL FL Kg.
E FL FL FL FL %FLC %FLT % FLC % FLT
93.0 125.0 6 C280M 980 182.0 166.0 92.5 92.0 90.0 0.84 0.80 0.72 550 225 155 60 13.45 710
93.0 125.0 8 C315S 740 190.0 173.0 93.0 92.0 90.0 0.80 0.76 0.68 500 120 140 35 19.16 865

110.0 150.0 2 C250M 2950 206.0 188.0 90.0 89.0 87.0 0.90 0.86 0.78 600 200 170 55 4.70 480
110.0 150.0 4 C280S 1475 200.0 183.0 93.0 92.5 90.5 0.90 0.86 0.78 600 150 170 40 7.44 620
110.0 150.0 6 C315S 980 214.0 196.0 93.0 92.5 90.5 0.84 0.80 0.72 550 225 155 60 17.50 865
110.0 150.0 8 C315M 740 225.0 205.0 93.0 92.0 90.0 0.80 0.76 0.68 500 225 140 60 20.83 950

132.0 175.0 2 C280M 2930 248.0 227.0 90.0 89.0 87.0 0.90 0.86 0.78 600 150 170 40 5.00 710
132.0 175.0 4 C280M 1480 240.0 219.0 93.0 92.5 90.5 0.90 0.86 0.78 600 150 170 40 8.72 710
132.0 175.0 6 C315M 980 257.0 235.0 93.0 92.5 90.5 0.84 0.80 0.72 550 225 155 60 20.83 950
132.0 175.0 8 C315MX 740 270.0 246.0 93.0 92.0 90.0 0.80 0.76 0.68 500 120 140 35 30.00 1150

160.0 215.0 2 C315S 2940 294.0 268.0 92.0 91.0 89.0 0.90 0.86 0.78 600 140 170 40 7.45 865
160.0 215.0 4 C315S 1475 304.0 278.0 93.0 92.0 90.0 0.86 0.82 0.74 500 225 140 60 16.00 865
160.0 215.0 6 C315MX 985 313.0 286.0 92.5 92.0 90.0 0.84 0.80 0.72 550 225 155 60 30.00 1150

185.0 250.0 2 C315M 2940 339.0 315.0 92.0 91.0 89.0 0.90 0.86 0.78 600 140 170 40 8.71 950
185.0 250.0 4 C315M 1475 356.0 329.0 93.0 92.0 90.0 0.85 0.81 0.73 500 225 140 60 17.40 950
185.0 250.0 6 C315MX 985 362.0 334.0 92.5 92.0 90.0 0.84 0.80 0.72 550 225 155 60 30.00 1150

200.0 270.0 2 C315M 2950 367.0 336.0 92.0 91.0 89.0 0.90 0.86 0.78 600 140 170 40 8.71 950
200.0 270.0 4 C315M 1475 380.0 361.0 93.0 92.0 90.0 0.86 0.81 0.73 600 225 140 60 17.40 960

220.0 300.0 2 C315MX 2950 404.0 370.0 92.0 91.0 89.0 0.90 0.86 0.78 600 140 170 40 11.60 1150
220.0 300.0 4 C315MX 1475 423.0 387.0 93.0 92.0 90.0 0.85 0.81 0.73 500 225 140 60 22.30 1150

250.0 335.0 2 C315MX 2950 459.0 420.0 92.0 91.0 89.0 0.90 0.86 0.78 600 140 170 40 11.60 1150
250.0 335.0 4 C315MX 1475 481.0 439.0 93.0 92.0 90.0 0.85 0.81 0.73 500 225 140 60 25.00 1150

The above data is subject to tolerance as per the


applicable standard.
** These Frames are for Australian
Standards AS1359 / AS1360 or South
African Standard SABS 948 Part I-1978.
* These outputs have Class ‘F’ temperature
rise.
The above data is subject to tolerance as
per the applicable standard.
FL - Full Load, STG - Starting, C - Current,
T - Torque, DOL - Direct on Line,
S/D-Star/Delta

40
DRIP PROOF
SQUIRREL CAGE
MOTORS

SHIPPING SPECIFICATIONS
FOOT MOUNTED MOTORS

NETT WEIGHT GROSS WEIGHT DIMENSIONS VOLUME


FRAME
KG KG L IN MM B IN MM H IN MM CUBIC METRES
C160M 121 192 725 610 533 0.24

C160L 131 202 725 610 533 0.24

C180M 185 291 850 690 588 0.34

C180L 205 311 850 690 588 0.34

C200M 260 366 980 800 673 0.53

C200L 300 406 980 800 673 0.53

C225M 340 446 980 800 673 0.53

C250S 425 563 1150 870 738 0.74

C250M 480 618 1150 870 738 0.74

C280S 620 834 1500 1170 900 1.58

C280M 710 924 1500 1170 900 1.58

C315S 865 1118 1600 1170 980 1.83

C315M 950 1203 1600 1170 980 1.83

C315MX 1150 1403 1600 1170 980 1.83

FLANGE MOUNTED MOTORS


NETT WEIGHT GROSS WEIGHT DIMENSIONS VOLUME
FRAME
KG KG L IN MM B IN MM H IN MM CUBIC METRES
C160MD 130 202 725 610 533 0.24

C160LD 140 212 725 610 533 0.24

C180MD 195 267 850 690 588 0.34

C180LD 215 287 850 690 588 0.34

C200LD 310 452 980 800 673 0.53

C225MD 360 502 980 800 673 0.53

C250MD 495 725 1150 870 738 0.74

C280MD 725 991 1500 1170 900 1.58

C315MD 980 1308 1600 1170 980 1.83

C315MXD 1190 1518 1600 1170 980 1.83

The standard packing is wooden for all above


motors.

41
DRIP PROOF
SQUIRREL CAGE
MOTORS

DIMENSIONS OF FOOT MOUNTING MOTORS


IN FRAME C160 TO C200

AUXILIA RY TERMINAL BOX FOR SPACE HEATER/THERMISTORS


ABOVE 200 FRAME WHEN SPECIFIED
AC
L±5

AD AIR OUTLET AIR INLET

+ 0.0
N9 / h9 – 0.5
GD

ED
60
G

HD
H

ØD
HA

4-HOLES Ø K BA
AA
A ± 0.5 E ± 0.5 C ±1 B ± 0.5
AB BB

Y - THREADED CENTRE HOLES


EARTHING TERMINALS OF M8 SIZE CABLE ENT RY SCREWED FOR 'KK', B.S. CONDUIT
Y × DEPTH ON BOTH SIDES

FOOT FIXING SHAFT AND KEY OVERALL (MAX.)


FRAME
A B C H AA AB BA BB K D E ED F GD G Y×Depth AD AC L HD HA KK

2 Nos.- 2 Nos.- 2 Nos.-


C160M 210 160.0 254 15.5 48.018 14.0 9.00 42.002 536

1"
254 108 54 298 76 110 80 M16×32 290 390 395 22
C160L 254 159.7 298 15.0 48.002 13.957 8.91 42.3 580

C180M 241 180.0 285 15.5 55.030 16.0 10.00 49.0 593
279 121 60 337 95 110 80 335 420 445 22 1"
C180L 279 179.7 323 15.0 55.011 15.957 9.91 48.8 631
M20×40
C200M 267 200.0 318 19.5 60.030 140 110 18.0 11.0 53.0 673
1.5"

305 133 65 381 105 398 460 498 25


C200L 318 199.5 355 19.0 60.011 17.959 10.91 52.8 711

1. All dimensions are in mm, unless specified.


2. Cable entries can be rotated through 360° in
steps of 90°.
3. Compression type cable glands can be fitted
when specified.
4. All dimensions are subject to confirmation.
Certified Drawings will be sent on request.

42
DRIP PROOF
SQUIRREL CAGE
MOTORS

DIMENSIONS OF FOOT MOUNTING MOTORS


IN FRAME C225 TO C315

AUXILIA RY TERMINAL BOX FOR SPACE HEATER/THERMISTOR ONLY WHEN SPECIFIED

AC
L ±5

AD AIR OUTLET AIR INLET

+0.0
-0.5
N9/h9
GD

ED
F
HD
G

ØD
HA

AA BA
A ± 0.5 E±0.5 C±1 B±0.5
Y - THREADED CENTRE HOLES AB BB
Y × DEPTH
4 - HOLES Ø K

EARTHING TERMINALS OF M8 SIZE ON BOTH SIDES


AND M12 FOR FOR 280-315 FRAME

CABLE ENT RY SCREWED FOR 'KK' BS CONDUIT

FOOT FIXING SHAFT & KEY OVERALL (MAX.)


FRAME
A B C H TOL AA AB BA BB K TOL D TOL E ED F TOL GD TOL G Y×Depth AD AC L HD HA KK

2Nos. 1.5"
225.0 19.5 65.030 19.5 65.030 58.0
C225M 356 311 149 70 426 125 427 140 110 M20X40 398 450 800 520 25
224.5 19.0 5.011 19.0 5.011 57.8
C250S 311 381 787
225.0 24.5 75.030 24.5 75.030 67.5
C250M 406 168 80 483 127 140 110 428 500 825 600 28
C250MX 349 249.5 419 24.0 75.011 24.0 75.011 67.3 927
M20X40
2Nos.-2"
C280S 368 438 918
280.0 24.5 80.030 24.5 80.030 71.0
C280M 447 190 83 540 146 170 140 551 560 969 663 35
C280MX 419 279.0 489 24.0 80.011 24.0 80.011 70.8 1071
C315S 406 315.0 482 28.5 90.035 28.5 90.035 81.0 1008
C315M 508
457 216 314.0 89 597 153 533
28.0 90.013
170 140
28.0 90.013 80.8
M24X50 630 1059 734 38
C315MX 1186

FRAME L
D E ED F TOLERANCE GD TOLERANCE G
S M L
ABOVE 200 FRAMES C225 60.030 / 60.001 140 110 18.0 / 17.957 11.0 / 10.91 53.0 / 52.8 – 800 –
MACHINES RUNNING
AT 3000 RPM HAVE C225 65.030 / 66.001 140 110 18.0 / 17.957 11.0 / 10.91 53.0 / 52.8 787 825 927
SMALLER SHAFTS
AS SHOWN HERE C280 65.030 / 66.011 140 110 18.0 / 17.957 11.0 / 10.91 58.0 / 57.8 888 939 1041

C315 70.030 / 70.011 140 110 20.0 / 19.948 12.0 / 11.91 62.5 /62.3 978 1029 1156

1. All dimensions are in mm, unless specified.


2. Cable entries can be rotated through 360° in
steps of 90°.
3. Compression type cable glands can be fitted
when specified.
4. All dimensions are subject to confirmation.
Certified Drawings will be sent on request.

43
DRIP PROOF
SQUIRREL CAGE
MOTORS

DIMENSIONS OF FLANGE MOUNTING MOTORS


IN FRAMES C160 TO C315

4 - HOLES FOR FRAMES 160 - 180

8 - HOLES FOR FRAMES 200 - 250


AUXILIA RY TERMINAL BOX FOR SPACE HEATER /
DRILL Ø 'S' ON 'M' P.C.D.
THERMISTORS, ABOVE 200 FRAME ON LY
EQUAL LY SPACED AS SHOWN
AC CONCENTRICITY
L ±5
AC

AD
T LB AIR INLET
AIR OUTLET

N9 / h9 F +0.0
- 0.5
22°30°

HB
GD ED

Ø N SPIGOT
45°

ØP
G

ØD

+0 LA
PERPENDICULARITY +2
E
'Y' - THREADED CENTRE HOLES 2 - LIFTING EYEBOLTS FOR VERTICAL
Y × DEPTH MOTORS ABOVE 200 FRAMES ON LY

CABLE ENT RY SCREWED FOR 'KK' B.S.C.

FLANGE FIXING SHAFT & KEY OVERALL (MAX.)


FRAME
M TOL. N TOL. P S T LA D TOL E ED F TOL. GD TOL. G Y×Depth AD AC L LB HB KK

2 Nos.-1"
C160MD 48.018 14.00 9.00 42.5 536 213
110 80 M16×32 290 325 235
C160LD 350.5 300.016 48.002 13.957 8.91 42.3 580 235
400 19.9 5 19
C180MD 349.5 299.984 55.030 16.00 10.00 49.0 593 241.5 265
110 80 M20×40 335 352
C180LD 55.011 15.957 9.91 48.8 631 260.5
C200MD 400.5 350.018 60.030 18.00 11.00 53.0 673 266.5
450 19 5 19 140 110 398 450 298
C200LD 399.5 349.982 60.011 17.957 10.91 52.8 711 285.5
500.5 450.020 65.030 18.00 11.00 58.0
550 19 5 25 140 110 398 550 304.5 295
2 Nos.-2"

C225MD 825
499.5 449.980 65.011 17.957 10.91 57.8
M20×40
C250MD 601.0 550.022 75.030 20.00 12.00 67.5 927 342.5
660 24 6 25 140 110 428 520 355
C250MXD 599.0 549.978 75.011 19.948 11.91 67.3 969 342.5
C280MD 601.0 550.022 80.030 22.00 14.00 71.0 1071 399.5
660 24 6 25 170 140 515 794 383
C280MXD 599.0 549.978 80.011 21.948 13.91 70.8 1059 399.5
C315MD 741.0 680.025 90.035 25.00 14.00 81.0 555 810 444.5
800 24 6 28 170 140 M24×50 965 419
C315MXD 739.0 679.975 90.013 24.948 13.91 80.8 576 1186 444.5
L
FRAME D TOLERANCE E ED F TOLERANCE GD TOLERANCE G
MD MXD
C225 60.030 / 60.001 140 110 18.0 / 17.957 11.0 / 10.91 53.0 / 52.8 800 –
MACHINES RUNNING
AT 3000 RPM HAVE C250 825 927
SMALLER SHAFTS 65.030 / 65.011 140 110 18.0 / 17.957 11.0 / 10.91 58.0 / 57.8
C280 939 1041
AS SHOWN HERE
C315 70.030 / 70.011 140 110 20.0 / 19.948 12.0 / 11.91 62.5 / 62.3 1029 1156

CONCENTRICITY IN MICRONS PERPENDICULARITY IN MICRONS RUNOUT IN MICRONS


FRAME
NORM. NORM. Ø SHAFT NORM.
30-50 50
C225 125 125 50-80 60
For notes please
90 70 refer to page 42

44
DRIP PROOF
SLIPRING
MOTORS

APPLICATION BRUSHGEAR AND SLIPRINGS


Drip-proof Slipring motors are specially The sliprings and brushgears are simple to
designed for applications where use of cage assemble. They are enclosed by a cover held
motors is not permitted or where a high in place against a grommet in a groove in the
starting torque and/or prolonged starting time endshield, by means of studs and wingnuts to
is required with low starting current. The allow easy access for maintenance. However,
standard designs are suitable for all normal motors in DW132 frame size have brushgear
industrial drives. Motors are also available for and sliprings inside the motor housing which
drives requiring special characteristics. also provides easy access for maintenence.
As sliprings are continuously rated, a short
ENCLOSURE circuiting handle is not required.
Drip-proof motors have ventilated openings in In all frames, the sliprings are of the moulded
the endshields which are protected by screens type which gives stability and a high degree of
so that accidental contact with the moving anti-tracking, besides being easy to clean.
parts is eliminated.
TERMINALS AND CABLE ARRANGEMENTS
The degree of protection is IP 21.
The terminals are mounted on a moulded
PERFORMANCE AND DIMENSIONS base and enclosed in a box having an
inspection cover. The terminal boxes are
The standard motors are Class "F" insulated,
suitable for British Standard screwed
continuous rated suitable for S1 duty and have
conduit as a standard practice.
maximum temperature rise restricted to class
Compression glands suitable for PVC
'B' limits. (measured by the resistance method)
armoured cables can be fitted, if required.
over an ambient of 45°C at a maximum altitude
Stator and rotor terminals are terminated in
of 1000 metres. Motors can also be supplied for
the same terminal box.
other duty cycles (S2 to S8) on request.
The standard position of the stator terminal
All motors comply with IEC standards.
box is on the left hand side when looking from
STATOR FRAME AND ENDSHIELDS the non-driving end of the motor. It can be
arranged instead on the right hand side, if
The stator frame is of cast iron. In case of foot required.
mounted motors, the frame and feet are cast
integrally. The end shields are also of cast iron. STARTING
CORES A starting torque of 100% full load torque
(FLT) is available with starting current of
Both stator and rotor cores consist of high approximately 250% full load current (FLC)
quality magnetic steel stampings. by using suitable starter. If required,
WINDINGS AND INSULATION increased torques can be obtained, with
corresponding increased starting torques
The stator and rotor windings consist of and increased starting currents.
synthetic enamel-covered copper wire or strip The rotors are specially designed to obtain
with slot insulation complying with IEC require- rotor volts and amperes which will result in a
ments. All windings are completely immersed most economical arrangement of customers'
for a predetermined period in a synthetic resin control gear and cabling.
varnish of a consistency which ensures
complete penetration. They are then baked in INTERCHANGEABILITY AND SPARES
special heat regulated ovens at the correct
temperature. The varnish polymerises and sets All motors are built to standardised designs,
giving rigidity at all working temperatures. It has machined to fine limits and all spare parts are
a high insulation resistance and a high interchangeable.
resistance to moisture, saline atmosphere, acid TESTS
or alkaline fumes and also to oil and grease. The
impregnation gives complete reliability under all All motors are tested in the course of
conditions, including humid tropical conditions. manufacture and before despatch in accor-
dance with IEC standards.
BEARINGS AND SHAFTS
SPECIAL FEATURES
Ball and roller bearings are used. Grease
nipples are fitted to both bearing housings Special features are available to meet
on all foot mounted motors. Shafts are specific requirements of customers such as
machined to extremely fine limits to ensure special shafts, high altitudes, different duty
fit and interchangeability of bearings. cycles, etc.

45
DRIP PROOF
SLIPRING
MOTORS

PERFORMANCE DATA
Supply : 415 V or 380 V, 50 Hz, 3 Phase AC Voltage Variation : ± 10%
Enclosure : Screen Protected, Drip Proof (SPDP) Frequency Variation : ± 5%
Degree of Protection : IP21 for Frames upto 200,
Combined Variation : ± 10%
IP23 for Frames 225 - 315MX
Rating: Continuous, Duty: S1 Mounting : B3, Ambient : 45°C
Insulation Class : ‘F’ Temperature Rise by Resistance Method : 75°C Max.
P
OUTPUT FL FL EFFICIENCY (%) POWER FACTOR OPEN CIRCUIT ROTOR NETT
O FRAME FL GD²
AMPS AMPS ROTOR VOLTAGE CURRENT WEIGHT
L RPM 3/4 1/2 3/4 1/2 KgM²
380 V 415 V FL FL VOLTS AMPS Kg.
kW HP E FL FL FL FL
3.7 5.0 8 CW160M 700 11.0 10.0 78.0 77.0 75.0 0.68 0.64 0.56 230 9 0.51 130
5.5 7.5 6 CW160M 935 15.5 14.0 80.0 79.0 77.0 0.72 0.68 0.60 280 13 0.51 130
5.5 7.5 8 CW160L 700 15.5 14.0 80.0 79.0 77.0 0.68 0.64 0.56 235 15 0.65 150
7.5 10.0 4 CW160M 1410 17.5 16 82 81 79 0.82 0.78 0.7 375 12 0.41 130
7.5 10.0 6 CW160L 935 19.0 17.0 83.0 82.0 80.0 0.72 0.68 0.60 260 19 0.65 150
7.5 10.0 8 CW180M 705 21.0 19.0 82.0 81.0 79.0 0.68 0.64 0.56 350 13 1.14 200
9.3 12.5 4 CW160L 1420 21.0 19.0 83.0 82.0 80.0 0.82 0.78 0.70 380 16 0.53 150
9.3 12.5 6 CW180M 940 21.0 19.0 83.0 82.0 80.0 0.82 0.78 0.70 300 20 1.14 200
9.3 12.5 8 CW180L 705 26.0 24.0 82.0 81.0 79.0 0.68 0.64 0.56 345 17 1.45 220
11.0 15.0 4 CW160L 1420 24.0 22.0 84.0 82.0 80.0 0.82 0.78 0.70 390 18 0.53 150
11.0 15.0 6 CW180M 940 25.0 23.0 83.0 82.0 80.0 0.82 0.78 0.70 300 23 1.14 200
11.0 15.0 8 CW180L 705 29.5 27.0 82.0 81.0 79.0 0.70 0.66 0.58 345 20 1.45 220
15.0 20.0 4 CW180M 1420 34.0 31.0 83.0 82.0 80.0 0.82 0.78 0.70 390 23 0.53 150
15.0 20.0 6 CW180L 945 34.0 31.0 83.0 82.0 80.0 0.82 0.78 0.70 320 28 1.33 220
15.0 20.0 8 CW200M 720 38.0 35.0 84.0 83.0 81.0 0.71 0.67 0.59 300 30 2.20 275
18.5 25.0 4 CW180M 1420 39.5 36.0 84.0 83.0 81.0 0.86 0.80 0.72 435 26 0.91 200
18.5 25.0 6 CW200M 960 41.5 38.0 86.0 85.0 83.0 0.78 0.74 0.66 380 26 2.20 275
18.5 25.0 8 CW200L 720 47.0 43.0 84.0 83.0 81.0 0.72 0.68 0.60 300 38 2.20 299
22.0 30.0 4 CW180L 1420 46.0 42.0 86.0 85.0 83.0 0.84 0.80 0.72 445 29 1.16 220
22.0 30.0 6 CW200L 965 50.0 46.0 86.0 85.0 83.0 0.78 0.74 0.66 380 35 2.30 299
22.0 30.0 8 CW225M 720 53.5 49.0 86.0 85.0 83.0 0.73 0.69 0.61 350 39 3.35 380
30.0 40.0 4 CW200M 1440 62.0 57.0 87.0 86.0 84.0 0.84 0.80 0.72 415 45 1.79 275
30.0 40.0 6 CW225M 965 65.0 60.0 88.0 87.0 85.0 0.78 0.74 0.66 390 45 3.35 380
30.0 40.0 8 CW225M 720 71.0 65.0 87.0 86.0 84.0 0.74 0.70 0.62 355 51 3.35 380
37.0 50.0 4 CW200L 1440 76.5 70.0 87.0 86.0 84 0.84 0.80 0.72 465 47 2.11 299
37.0 50.0 6 CW225M 970 81.0 74.0 89.0 88.0 86 0.78 0.74 0.66 430 50 3.35 380
37.0 50.0 8 CW250S 720 86.5 79.0 89.0 88.0 86 0.74 0.70 0.62 465 50 5.70 455
45.0 60.0 4 CW225M 1450 89.5 82.0 89.0 88.0 86.0 0.85 0.81 0.73 440 60 2.66 380
45.0 60.0 6 CW250S 970 96.0 88.0 89.0 88.0 86.0 0.80 0.76 0.68 450 58 5.70 455
45.0 60.0 8 CW250M 725 104.0 95.0 89.0 88.0 86.0 0.74 0.70 0.62 480 59 6.66 525
55.0 75.0 4 CW225M 1460 111.5 102.0 89.0 88.0 86.0 0.84 0.80 0.72 440 78 2.65 380
55.0 75.0 6 CW250M 975 114.0 104.0 90.0 89.0 87.0 0.82 0.78 0.70 460 75 6.66 525
55.0 75.0 8 CW280S 730 119.0 109.0 90.0 89.0 87.0 0.78 0.74 0.66 425 79 10.65 635
75.0 100.0 4 CW250S 1460 147.5 135.0 90.5 90.0 88.0 0.84 0.80 0.72 505 88 4.77 455
75.0 100.0 6 CW280S 975 146.5 134.0 91.5 91.0 89.0 0.85 0.81 0.73 410 113 10.09 635
75.0 100.0 8 CW280M 730 163.0 149.0 90.0 89.0 87.0 0.78 0.74 0.66 536 83 13.44 750
93.0 125.0 4 CW250MX 1460 179.0 164.0 92.0 91.0 89.0 0.86 0.82 0.74 500 110 7.15 695
93.0 125.0 6 CW280M 975 180.0 165.0 92.0 91.0 89.0 0.85 0.81 0.73 520 111 13.44 750
93.0 125.0 8 CW315S 730 204.0 187.0 91.5 91.0 89.0 0.76 0.72 0.64 490 112 19.16 870
110.0 150.0 4 CW280S 1465 211.0 193.0 92.0 91.0 89.0 0.86 0.82 0.74 480 142 9.23 635
110.0 150.0 6 CW315S 975 215.0 197.0 92.5 92.0 90.0 0.84 0.80 0.72 495 140 17.50 870
110.0 150.0 8 CW315M 730 238.0 218.0 91.5 91.0 89.0 0.77 0.73 0.65 350 190 21.66 980
132.0 180.0 4 CW280M 1475 251.0 230.0 92.5 92.0 90.0 0.86 0.82 0.74 480 167 11.07 750
132.0 180.0 6 CW315M 975 258.0 236.0 92.5 92.0 90.0 0.84 0.80 0.72 450 180 20.83 980
132.0 180.0 8 CW315MX 730 280.0 256.0 92.0 91.0 89.0 0.78 0.74 0.66 490 157 26.66 1200

46
DRIP PROOF
SLIPRING
MOTORS

PERFORMANCE DATA (Continued)


P
OUTPUT FL FL EFFICIENCY (%) POWER FACTOR OPEN CIRCUIT ROTOR NETT
O FL GD²
FRAME AMPS AMPS ROTOR VOLTAGE CURRENT WEIGHT
L RPM 3/4 1/2 3/4 1/2 KgM²
380 V 415 V FL FL VOLTS AMPS Kg.
kW HP E FL FL FL FL
160.0 215.0 4 CW315S 1470 305.0 279.0 92.5 92.0 90.0 0.86 0.84 0.76 465 206 14.64 870
160.0 215.0 6 CW315MX 975 307.0 281.0 93.0 92.0 90.0 0.85 0.81 0.73 480 196 26.66 1200

185.0 250.0 4 CW315M 1470 357.0 327.0 92.5 92.0 90.0 0.86 0.82 0.74 540 207 17.43 980

200.0 270.0 4 CW315MX 1475 379.0 347.0 93.0 92.0 90.0 0.86 0.82 0.74 540 224 20.91 1200

220.0 300.0 4 CW315MX 1475 417.0 382.0 93.0 92.0 90.0 0.86 0.82 0.74 540 246 20.91 1200
The above data is subject to tolerance as per the
applicable standard.
FL - Full Load, STG - Starting, C - Current,
T - Torque, DOL - Direct on Line, S/D-Star/Delta

SHIPPING SPECIFICATIONS
FOOT MOUNTED MOTORS

NETT WEIGHT GROSS WEIGHT DIMENSIONS VOLUME


FRAME KG KG L IN MM B IN MM H IN MM CUBIC METRES
CW160M 130 201 875 705 585 0.36

CW160L 150 221 875 705 585 0.36

CW180M 200 306 1025 825 700 0.59

CW180L 220 326 1025 825 700 0.59

CW200M 275 394 1150 845 710 0.69

CW200L 300 419 1150 845 710 0.69

CW225M 380 518 1300 915 745 0.89

CW250S 455 593 1300 915 745 0.89

CW250M 525 663 1300 915 745 0.89

CW250MX 695 948 1600 1170 925 1.73

CW280S 635 888 1600 1170 925 1.73

CW280M 750 1003 1600 1170 925 1.73

CW315S 870 1123 1600 1170 925 1.73

CW315M 980 1233 1600 1170 925 1.73

CW315MX 1200 1453 1600 1170 925 1.73

The standard packing is wooden for all above


motors.

47
DRIP PROOF
SLIPRING
MOTORS

DIMENSIONS OF FOOT MOUNTING MOTORS


IN FRAMES CW160 TO CW200

AUXILIARY TERMINAL BOX FOR SPACE


HEATER/THERMISTORS ABOVE 200 FRAME WHEN SPECIFIED.
AC
L±5

AD AIR OUTLET AIR INLET

+ 0.0
N9 / h9 – 0.5
GD

ED
60
G

HD
H

ØD
HA

AA BA
A ± 0.5 E ± 0.5 C ±1 B ± 0.5
Y - THREADED CENTRE HOLES AB BB
Y × DEPTH
4-HOLES Ø K

EARTHING TERMINALS OF M8 SIZE ON BOTH SIDES


CABLE ENTRY SCREWED FOR 'KK'B5 CONDUIT

FOOT FIXING SHAFT AND KEY OVERALL (MAX.)


FRAME
A B C H TOL AA AB BA BB K TOL D E ED F TOL GDTOL G Y×Depth AD AC L HD HA KK
2 Nos.- 2 Nos.- 2 Nos.-
CW160M 210 160.0 254 15.5 48.018 14.0 9.00 42.002 536
M16X32 290 390
1"
254 108 54 298 76 110 80 395 22
CW160L 254 159.7 298 15.0 48.002 13.957 8.91 42.3 580

CW180M 241 180.0 285 15.5 55.030 16.0 10.00 49.0 593
1"

279 121 60 337 95 110 80 335 420 445 22


CW180L 279 179.7 323 15.0 55.011 15.957 9.91 48.8 631
M20X40
CW200M 267 200.0 318 19.5 60.030 18.0 11.0 53.0 673
1.5"

318 133 65 381 105 140 110 398 460 498 25


CW200L 305 199.5 355 19.0 60.011 17.959 10.91 52.8 711

1. All dimensions are in mm, unless specified.


2. Cable entries can be rotated through 360° in
steps of 90°.
3. Compression type cable glands can be fitted
when specified.
4. All dimensions are subject to confirmation.
Certified Drawings will be sent on request.

48
DRIP PROOF
SLIPRING
MOTORS

DIMENSIONS OF FOOT MOUNTING MOTORS


IN FRAME CW225 TO CW315

AUXILIARY TERMINAL BOX FOR SPACE HEATER/THERMISTORS WHEN SPECIFIED.

AC
L±5

AD AIR OUTLET AIR INLET

+ 0.0
– 0.5
N9 / h9
ED
GD

60
G

HD

ØD
HA

AA BA
A ± 0.5 E ± 0.5 C ±1 B ± 0.5
Y - THREADED CENTRE HOLES AB BB
Y × DEPTH
4-HOLES Ø K

EARTHING TERMINALS OF M8 SIZE ON BOTH SIDES


AND M12 FOR 280-315 FRAME

FOOT FIXING SHAFT & KEY OVERALL (MAX.)


FRAME
A B C H TOL AA AB BA BB K TOL D TOL E ED F TOL GD TOL G Y AD AC L HD HA KK
M20X40

2Nos. 1.5"
225.0 19.5 65.030 19.5 65.030 58.0
CW225M 356 311 149 70 426 125 427 140 110 398 450 800 520 25
224.5 19.0 65.011 19.0 5.011 57.8
CW250S 311 381 787
24.5 75.030 24.5 75.030 67.5
CW250M 406 168 225.0 80 483 127 140 110 428 500 825 600 28 2Nos.-2"
M20X40

CW250MX 349 419 24.0 75.011 24.0 75.011 67.3


249.5 927
CW280S 368 438 918
24.5 80.030 24.5 80.030 71.0
CW280M 447 190 280.0 83 540 146 170 140 515 560 969 663 35
CW280MX 419 489 24.0 80.011 24.0 80.011 70.8
279.0 1071
2Nos.-2"
M24X50

CW315S 406 482 1008


315.0 28.5 90.035 28.5 90.035 81.0 555
CW315M 508 216 89 597 153 533 170 140 630 1059 734 38
457 28.0 90.013 28.0 90.013 80.8
CW315MX 314.0 576 1186

1. All dimensions are in mm, unless specified.


2. Cable entries can be rotated through 360° in
steps of 90°.
3. Compression type cable glands can be fitted
when specified.
4. All dimensions are subject to confirmation.
Certified Drawings will be sent on request.

49
SELECTION OF MOTORS

The following four areas should be considered adjustable speed.


when selecting a motor for a particular – required speed range.
application : – method of speed change.
The mechanical requirements of the Starting and stopping :
driven load. frequency of starting and stopping.
The electrical distribution system. starting torque requirement.
Physical and environmental considerations. acceleration restrictions.
Efficiency and economic considerations. requirements for braking.
The ultimate selection will optimise these – mechanical
considerations and the motors available – plugging
from various motor manufacturers. From this information the size and design
DRIVEN LOAD characteristics of the motor, as well as
drive, control and braking requirements can
For a motor to drive a load properly, it must be determined.
produce enough torque to accelerate from
standstill to operating speed, and supply INDUCTION MOTOR SELECTION
enough power for all possible demands Squirrel cage induction motors are often
without exceeding its design limits. referred to as the "workhorses of the
To specify the motor properly, the following industry" because they are low in cost
characteristics of the load should be and reliable. They suit most applications
considered : and have the best availability.
Running characteristics : These standard designs are suited to
continuous running, constant load. particular classes of applications based on
– horsepower requirement. the load requirements typical of each class.
continuous running, varying load. Squirrel cage motors have minimal
– peak horsepower requirement. maintenance requirements and are
frequently the choice of users.
cyclical load.
– duty cycle. Wound rotor induction motors are useful in
– peak torque and horsepower some applications because their rotor
requirements. circuits can be altered to give the desired
– load inertia. starting or running characteristics.
However, they require brush servicing and
Speed :
maintenance.
constant speed.
The following table can be used to help
multi-speed. determine which design type should be
– speeds required. selected :

Induction Motor Selection


Starting Breakdown
Torque Torque
(Percent Full (Percent Full Starting Slip Typical Applications
Classification Load Torque) Load Torque) Current
Normal starting Fans, blowers, centrifugal pumps,
torque and normal 100-200% 200-250% Normal <5% compressors, etc., where starting
starting current torque requirements are relatively low
High starting Conveyors, crushers, stirring machines,
torque and normal 200-250% 200-250% Normal <5% agitators, reciprocating pumps, compressors,
starting current etc., where starting under load is required.
High peak loads, loads with flywheels
High starting torque 275% 275% low >5% such as punch presses, shears, elevators,
and high slip extractors, winches, hoists, oil-well pumping
and wire drawing machines
Any torque Depends Depends on Where high starting torque with low inrush,
up to the on starting rotor frequent starting, or limited (2:1) speed
Wound Rotor 225-275%
breakdown torque resistance control are required, and where
value high inertia must be accelerated

50
SELECTION OF MOTORS

ELECTRICAL SUPPLY unbalance of greater than 1%, then the motor


should be derated according to the graph.
The electrical supply distribution system must
supply the correct voltage and have sufficient 1.0

capability to start and operate the motor load.

DERATING FACTOR
Voltage and Frequency
0.9
Motors are available in standard voltage
ranges :
- 220/230V, or 240V, single phase and 220/ 0.8
380V, 400/695V, 380V, 380/440V, three
phase. Frequency is 50Hz or 50/60Hz or
60Hz as required. 0.7
0 1 2 3 4 5
Other voltages and frequencies can be PERCENT VOLTAGE UNBALANCE
offered to meet special requirements.
Polyphase induction motors are designed to
operate successfully with voltage variations of Polyphase Squirrel-Cage Induction Motors
± 10%. The following table shows the effects Derating Factor Due to Unbalanced Voltage
of a 10% variation on a typical induction
motor at full load. A motor should not be operated if the phase
unbalance is greater than 3%.
Voltage
Characteristics Frequency variation of up to 5% is permitted
110% 90%
for normal motor operation. However,
Slip -17% +23%
generally this should not be a problem, if
Efficiency +1% -2% the system is supplied from a utility. Motor
Power factor -3% +1% speed varies directly with the frequency of
Current -7% +11% the power supply.
Temperature °C -4° +7°
Starting torque +21% -19% Power Factor
Starting current +10% -10% Most AC motors require reactive power from
the supply system to develop magnetic fields.
The use of a motor with a nonstandard or Measured in kVAR, reactive power does not
incorrect utilization voltage from the supply provide any mechanical work.
system should be avoided. For example, a
Useful mechanical work is developed from
motor with a nameplate voltage of 380 V is
sometimes connected to a 440 V system. real power supplied by the supply system
While the maximum allowable voltage for the and is measured in kW.
motor is 418 V (110% × 380) there is no The supply distribution system provides both
allowance for an upward supply voltage Real and Reactive power to operate the
variation as the motor is already operating motor. The vector sum Real and Reactive
above its upper voltage limit. A motor of the power is called the Apparent power and is
proper voltage rating should be used, or a expressed in kVA.
−−−−−−−−−−−−−−−−−−−−−−−
transformer installed to supply the correct Apparent Power = √ Real Power² + Reactive Power²
voltage.
The ratio of Real power to Apparent power is
Phase unbalance must be less than 1% for defined as the Power Factor.
proper motor operation. A phase unbalance of
Real Power
3.5% results in a temperature rise of 25% and Power Factor =
a current increase of 6-10 times the voltage Apparent Power
unbalanced. These effects are due to If the load consumes Reactive power from the
negative sequence currents flowing in the system, the power factor is said to be lagging.
rotor. Most electrical devices operate at a lagging
Voltage unbalance % is calculated as follows : power factor.

Maximum Deviation from Average The power factor of induction motors varies
V = × 100 with load.
unbalance V Average
The combined kW demand of all devices
As an example, if line voltages were supplied by the distribution systems divided
measured as 600, 585 and 609 volts, the by the combined kVA demand of all supplied
average is 598 volts. The maximum deviation devices yields the plant power factor.
from average is 13 volts (598-585), and thus
the voltage unbalance is (13/598)×100 = 2.1%
If a motor must be operated with a phase

51
SELECTION OF MOTORS

7.0
Penalties are usually charged by utilities if
plant power factor is below 90%, in which 6.0
case, correction such as capacitors should be POINT A
applied. 5.0

% VOLTAGE DIP
OBJECTIONABLE RANGE

Voltage Flicker 4.0


Threshold
of Objection
Starting motors or other large loads causes a 3.0 POINT B

voltage drop on the supply system which 2.0


may be perceived as a flicker in lighting NOT
OBJECTIONABLE
circuits. This flicker becomes objectionable 1.5 Threshold RANGE
when the magnitude of the voltage drop and 1.0 of Perception
0.5
the frequency of occurrence exceed certain 4 8 12 1 2 5 10 20 30 1 5 10 20 30 1 2 5 10 20 30
thresholds. This threshold of objection is PER DAY PER HR. PER MIN. PER SEC.

shown on a Voltage-Flicker curve. FREQUENCY OF VOLTAGE FLUCTU ATION


OF NUMBER OF STARTS
7.0
Voltage Flicker Curve - Example
6.0
The 6 V drop along the feeder is equal to 5%
% VOLTAGE DIP

5.0
OBJECTIONABLE RANGE of the voltage on the 120 V lighting circuit and
4.0
Thershold
causes a noticeable flicker.
of Objection
3.0
If the motor is started once every hour then
the point on the flicker curve is in the
2.0
NOT
objectionable range (point A).
OBJECTIONABL To correct this problem, the lighting circuits
1.5 Thershold E
1.0 of Perception can be supplied from a separate feeder, or
0 the voltage drop along the feeder can be
0 8 12 1 2 5 10 20 30 1 5 10 20 30 1 2 5 10 20 30
PER DAY PER HR. PER MIN. PER SEC. reduced. In this case, a drop of 3.6% or less
FREQUENCY OF VOLTAGE FLUCTU ATION
is not objectionable.
OR NUMBER OF STARTS
Supplying the lighting from a different feeder
or upgrading the feeder is one approach often
Voltage Flicker Curve
used.
If the magnitude of voltage drop and the A reduced voltage starter for the motor is
frequency of occurrence lie below the another alternative and often a very cost-
threshold of objection, but above the effective solution.
threshold of perception, people notice the light If the starting current is limited to 70% of its
flicker, but generally do not find it irritating. normal value by use of a reduced voltage
If the magnitude of the voltage drop and the starter, the voltage dip is 3.5% (70% × 5%)
frequency of occurrence lie below the and motor starting of once per hour is not
threshold of perception, people don't generally objectionable (point B).
notice any flicker.
PHYSICAL AND ENVIRONMENTAL
As an example, consider a 5 HP motor
supplied by a 208 V feeder which also CONSIDERATIONS
supplies 120 V lighting circuits.
Assume: 5 HP motor Usual Service Conditions
Full load amps = 16 A Motor ratings apply to motors operating under
Starting current = 96 A usual service conditions.
Feeder impedance = 0.06Ω The International Standards specify usual
Voltage drop along feeder environmental conditions as :
= starting current × feeder impedance
1. Exposure to an ambient temperature in the
= 96 × 0.06
range of 0°c to 40°C or when water cooling
= 6V
is used, in the range of 10°C to 40°C.
2. Exposure to an altitude which does not
exceed 3300 feet (1000 metres).
3. Installation on a rigid mounting surface.
4. Installation in areas or supplementary
enclosures which do not seriously interfere
with the ventilation of the machine.

52
SELECTION OF MOTORS

Unusual Service Conditions 6. Operation of a machine at standstill with


The manufacturer should be consulted if the any winding continuously energized, or of a
motor is to be operated in unusual service short-time-rated machine with any
conditions, such as mentioned below: winding continuously energized.
1. Exposure to : Enclosure
a. Combustible, explosive, abrasive, or The enclosure for the motor should be
conducting dusts. chosen to protect it from the expected
operating environment.
b. Lint or very dirty operating conditions
where the accumulation of dirt may Mounting
interfere with normal ventilation. Motors are generally mounted horizontally
c. Chemical fumes, flammable or explosive with feet attached to the floor, but other
gases. arrangements are common:
wall mounted
d. Nuclear radiation.
ceiling mounted
e. Steam, salt-laden air, or oil vapor. pedestal mounted
f. Damp or very dry locations, radiant heat, face mounted
vermin infestation, or atmospheres flange mounted
conductive to the growth of fungus. The size and length of the shaft can be
g. Abnormal shock, vibration, or specified if the standard shaft types or
mechanical loading from external sources. materials are not suitable for the required
h. Abnormal axial or side thrust imposed on mounting arrangement or machine
the motor shaft. configuration.
2. Operation where: Insulation
a. There is excessive departure from rated The type of insulation used in a motor
voltage or frequency, or both depends on the operating temperature that
the motor will experience. Motors are
b. The deviation factor of the alternating-
specified by ambient temperature and
current supply voltage excceds 10%.
insulation class.
c. The alternating-current supply voltage is
This table shows the maximum allowable
unbalanced by more than 1%. stator winding temperature for an operating
d. The rectifier output supplying a direct- life of 20,000 hr and a maximum ambient
current motor is unbalanced so that the temperature of 40°c.
difference between the highest and
lowest peak amplitudes of the current Class 20,000 Hr Life Temperature
pulses over one cycle exceed 10% of A 105°C
the highest pulse amplitude at rated B 130°C
armature current.
F 155°C
e. Low noise levels are required.
H 180°C
3. Operation at speeds above the highest
Maximum ambient temperature is 40°C.
rated speed.
4. Operation in a poorly ventilated room, in a Class A is an older classification. Class B and
pit, or in an inclined position. Class F are the current standard. Class H is
5. Operation subjected to: used for higher temperature applications.
a. Torsional impact loads. Average insulation life decreases rapidly
with increasing temperature. A cool running
b. Repetitive abnormal overloads.
motor will have a much longer insulation life.
c. Reversing or electric braking.
(continued on the next page)

53
SELECTION OF MOTORS

100,000
90,000
80,000
70,000
60,000
50,000
40,000
30,000 Average
INSULATION LIFE (HOURS)

Insulation Life
20,000
105° 130° 155° 180°

10,000
9,000
8,000
7,000
6,000
5,000
4,000
Class A Class F
3,000
Class B Class H
2,000

1,000
0 50 100 150 200 250 300

WINDING TEMPERATURE IN °C

Insulation Life vs Temperature

Service Factor EFFICIENCY AND ECONOMICS


Motor service factor is an indication of the
When selecting a motor for a particular
ability to exceed the mechanical power output
application both its capital cost and the cost of
rating on a sustained basis. A service factor
energy for operation should be considered.
of greater than 1.0 allows a margin for peak
horsepower demand without selecting the Energy Costs
next larger motor size. The cost of electricity to run a motor for
Motor efficiency is reduced during operation one year can easily exceed several times
at the service factor rating. the purchase price of the motor.
The following graph shows the operating
Service factors for higher temperatures or
cost for a typical 20 HP motor operating
high altitude (>3300 feet) can often be
for one year at 88% efficiency.
specified where required.
ANNUAL ENERGY COST THOUSAND $

Noise 9
8 Rate = 6¢/kwh
If a motor is used in an area where noise 7
levels are of concern, it should use 5¢/kwh
6
bearings which are quieter than roller or ball 4¢/kwh
5
bearings.
4
Quiet motors equipped with these bearings 3
and specially designed ventillation systems 2
can often be offered 1
Other Modifications 0

The standard motors suit almost all 0 2000 4000 6000 8000
applications. These are less expensive, have
proven engineering and are available on Annual operating Costs of a 20 HP Motor
shorter lead times. However, motors can be Because the operating cost over the life
ordered with an almost unlimited number of of a motor is often many times its purchase
variations to fit special applications where a price, small differences in motor efficiency can
standard motor is not suitable. We can yield significant savings.
provide specific information on availability,
Motor Efficiency
lead time and price.
The efficiency of a motor is the ratio of
mechanical power output to the electrical
power input and is usually expressed as a
percentage.

54
SELECTION OF MOTORS

Output Input - Losses Peak efficiency occurs between 75% and


Efficiency = × 100 = × 100 100% of full load depending on design, and
Input Input
drops significantly below about 30% of full
Motor losses consume electrical energy but load.
do not contribute useful mechanical energy
output. 100 HP
90
They occur in five areas:
10 HP
– Core losses 80
– Stator losses 1 HP
70
– Rotor losses
– Friction and windage

EFFICIENCY %
60

– Stray load losses.


50

Core Loss (25%) 40


Stator Loss (35%)
Rotor Loss (25%) 30
Friction &
Windage (10%)
20
Stray Loss (5%)

10

Electrical 0
0 25 50 75 100 125
Power In
% RATED LOAD

Typical Motor Efficiency vs Load

100%
Mechanical
Power Out 80%
%
POWER 60%
FACTOR
40%

Motor Losses 20%

0
Core losses are comprised of hysteresis
losses (the energy required to magnetize the 0 25% 50% 75% 100%

core) and eddy current losses in the stator % MOTOR LOAD


core (magnetically induced circulating Typical Power Factor vs Load
currents). Core losses make up about 25% of
the losses. Good engineering practice dictates slightly
oversizing a motor for the following reasons:
Stator losses are due to the I²R heating effect
– to allow for an increase in production.
of current flowing through the resistance of
– to accommodate load fluctuations and
the stator windings. They account for
overloads.
approximately 35% of the total.
– to accommodate the increase in load as
Rotor losses are caused by the I²R heating the driven load wears.
effect in the rotor. Rotor losses are – to increase motor operating life because of
responsible for about 25% of the total. lower winding temperatures.
Friction and windage losses include bearing – as insurance against motor failure in critical
friction, wind friction on the rotor assembly loads.
and the motor's cooling fan load. They make Sizing a motor for operation between 75%
up about 10% of the total. and 100% of full load provides what is
Stray load losses are defined as all other generally considered to be a reasonable
losses above the sum of the core, stator, margin. A service factor of 1.15 allows an
rotor and frictional losses. They are primarily additional 15% margin over full load to
due to leakage reactance fluxes induced by accommodate short term peak load
load current. Stray load losses make up conditions.
about 5% of the total. Induction motors should not be grossly
Efficiency And Motor Sizing oversized (<50% load) as the initial cost and
The efficiency of induction motors varies with energy costs are greater and the power factor
load. is lower.

Product improvement is a continuous process. Hence, data given in this catalogue is subject to change without intimation.
55
The widest Range of Motors, Alternators and Pumps
from Crompton Greaves

Single Phase / Three Phase FHP Motors Standard Re-Rolling Mill Duty motors and Special
(FHP Range) Dual Speed Induction Generators for Wind Mill Duty
From 90 watts to 2.25kW to BS 5000 part11 are offered.

Series 40 and Series 50 Frames Three Phase, HT, Induction and Synchronous
Machines (Large Machines Range)
DP, TEFC and TE(AOM) enclosures
Upto 6000 kW, SCR and SR. (Range being
General Purpose and Customer Specific
extended upto 8 MW)
For 120 Volts or 240 Volts, 50/60Hz. supply
Upto 20 poles.
suitability
CACA, TETV, SPDP, CACW, Flame proof, Type 'e',
CSA NRTL/C Listed for Canada and USA and with
Type 'n', Type 'p' enclosures.
CE mark for Europe
For 2.2kV, 3.3kV, 6.6kV, 11kV, 14.3kV, 50/60 Hz
Standard Three Phase, LT, Induction Motors
supply.
(M1 and M3 Range)
"Resin-Rich" alternatively "Resin-Poor" HIPACT-
From 0.18kW to 250kW, SCR and SR to IEC 325.
Hitachi Insulation offered.
Frames 63 to 355L.
S1 to S8 duty cycles for all applications.
DP, TEFC, TE, Flame proof (Type 'd'). Increased
Alternators
Safety (Type 'e'), Non-sparking (Type 'n'),
Pressurised (Type 'p') enclosures etc. From 5 KVA to 250 KVA, to generate 240 Volts,
0.8PF, 50/60 Hz, single phase and 415 Volts, 0.8PF,
For 110 to 660 volts, 50/60Hz supply.
50/60Hz, three phase, AC supply at 1500/1800 rpm,
Under CSA NRTL/C listing for Canada and USA
conforming to BS5000 (Part 99).
and with CE mark for Europe.
Brush and Brushless designs, revolving armature
S1 to S8 Duty Cycles for all applications.
and revolving field types, with self exited and self
Three Phase, LT, Induction Motors regulated exiter units.
(Large Machines Range)
For general purpose, marine and pully drive
From 150kW upto 1000kW, SCR and SR. applications.
Frames 315 to 710, 2 pole to 14 pole. Pumps
TEFC, DP, Type 'd', Type 'e', Type 'n', Type 'p' For Water Circulation Applications.
enclosures.
For single phase, and three phase supply.
Vertical and horizontal, foot cum flange mounting.
With 250 Watts to 80 kW motors.
For 400 to 690 volts, 50/60 Hz supply.
Coupled, monoblocks, Submersibles, Jet
S1 to S8 Duty Cycles for all applications. Centrifugals, In Line Pumps for Industrial,
Agricultural and Commercial applications.

56

Das könnte Ihnen auch gefallen