Sie sind auf Seite 1von 44

GPH13H

Packaged Heat Pump

P roduct S pecifications
The Goodman® brand GPH13H Packaged Heat
Pump provides energy-efficient cooling and heating
performance in one self-contained unit. The GPH13H is
housed in a heavy-gauge, galvanized-steel cabinet that
offers a high-quality, UV-resistant powder-paint finish
and allows for a ground-level or rooftop mount.

Standard Features
• Energy-efficient compressor with internal relief valve
• PSC blower motor; EEM blower motor on 5-ton units
• Quiet horizontal discharge
• Copper tube/aluminum fin coil
• Totally enclosed, permanently lubricated
condenser fan motor
• Fully charged system
• Electric heat kit available as a field-installed option
• AHRI Certified
• ETL Listed
Cabinet Features
13 SEER • Heavy-gauge galvanized-steel cabinet with
attractive Architectural Gray powder-paint finish
• Fully insulated blower compartment with
convenient access panels
2 to 5 Tons • Louvered condenser coil protection
• One footprint; three heights
Contents
Cooling Capacity: 25,000 - 57,000 BTU/h Nomenclature......................................................................2
Accessories..........................................................................2
Heating Capacity: 24,000 - 54,400 BTU/h Product Specifications.........................................................3
Dimensions..........................................................................6
Airflow Data.........................................................................7
Expanded Cooling Data......................................................10
Expanded Heating Data.....................................................34
Heat Kit Electrical Data......................................................37
Wiring Diagrams ...............................................................39

* To receive the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of
installation. Online registration is not required in California or Québec. Full warranty details available
at www.goodmanmfg.com.

SS-GPH13H www.goodmanmfg.com 3/10


Supersedes 12/09
Product Specifications

Nomenclature
G P H 13 36 H 2 1 A *
1 2 3 4,5 6,7 8 9 10 11 12

Brand Engineering
G Goodman Minor Revision
or Distinctions™

Product Category Engineering


P Packaged Unit Major Revision

Type Voltage Designator


H Heat Pump 1 208-230/1/60
C Air Conditioner 3 208-230/3/60
4 460/3/60

Efficiency Refrigerant
13 13 SEER 15 15 SEER 2 R-22
14 14 SEER 16 16 SEER 4 R-410A

Nominal Capacity Configuration


24 2 Tons 42 3½ Tons H Horizontal
30 2½ tons 48 4 Tons M Multi-position
36 3 Tons 60 5 Tons

Accessories
Item Description
OT/EHR18-60 Emergency Heat Relay kit
OT18-60A Outdoor Thermostat Kit with Lockout Stat
PCCP102/103 Roof Curb for for Medium/Large Chassis
PCE102/103 Downflow Economizer for for Medium/Large Chassis
PCEF102/103 Elbow & Flashing w/ R-8 Liner for Medium/Large Chassis
PCFR102/103 External Horizontal Filter Rack for Medium/Large Chassis
PCMD102/103 Manual Damper for Medium/Large Chassis
PCMDH102/103 Manual Damper for Medium/Large Chassis — Horizontal Applications
PCMDM102/103 Motorized Damper for Medium/Large Chassis
PCP102/103 Downflow Plenum Kit for Medium/Large Chassis
PCP102/103R8 Downflow Plenum Kit for Medium/Large Chassis
SQRPC101 Square-to-Round Adapter for Small Chassis — 16” Rounds
SQRPC102-103 Square-to-Round Adapter for Medium/Large Chassis — 18” Rounds
SQRPCH101 Square-to-Round Adapters Small Chassis for Small Chassis — 16” x 14”
SQRPCH102-103 Square-to-Round Adapters for Medium/Large Chassis — 18” x 14”

2 www.goodmanmfg.com SS-GPH13H
Product Specifications

Specifications
GPH13 GPH13 GPH13 GPH13 GPH13 GPH13
24H21A* 24H41** 30H21A* 30H41** 36H21A* 36H41**
Cooling Capacity
Total BTU/h 25,000 24,000 28,600 28,200 35,000 35,000
Sensible BTU/h 18,800 29,300 21,400 22,300 26,200 26,400
SEER / EER 13.0 / 10.8 13.0 / 11.0 13.0 / 10.8 13.0 / 11.0 13.0 / 11.0 13.0 / 11.0
Decibels 76 76 76 76 78 78
AHRI Numbers 735182 3414689 735177 3414691 735162 3414693
Heating Capacity
BTU/h (47°F) 24,000 22,000 27,400 27,000 33,600 33,600
C.O.P. (47°F) 3.4 3.4 3.2 3.4 3.4 3.5
BTU/h (17°F) 13,600 14,000 15,800 15,000 18,000 18,000
C.O.P. (17°F) 2.1 2.4 2.1 2.3 2.1 2.4
HSPF 7.7 7.7 7.7 7.7 7.7 7.7
Evaporator Motor
Type DD DD DD DD DD DD
Wheel (D x W) 9x6 9x6 9x6 9x6 9x8 9x8
Nominal Cooling CFM 875 875 1,080 1,080 1,205 1,205
RLA / LRA 1.5 / 2.2 1.5 / 2.2 2.4 / 3.2 1.86 / 3.2 2.4 / 3.2 1.86 / 3.2
No. of Speeds 3 3 3 3 3 3
Horsepower - RPM ¼ - 1,075 ¼ - 1,075 ⅓ - 1,075 ⅓ - 1,075 ⅓ - 1,075 ⅓ - 1,075
Evaporator Coil
Face Area (ft2) 4.6 4.6 4.6 4.6 6.2 6.2
Rows Deep / Fins per Inch 3 / 14 3 / 14 3 / 14 3 / 14 3 / 14 3 / 14
Filter Size (ft2) 20 x 20 x 1 20 x 20 x 1 20 x 25 x 1 20 x 25 x 1 25 x 25 x 1 25 x 25 x 1
Drain Size (NPT) ¾” ¾” ¾” ¾” ¾” ¾”
Refrigerant Charge (oz.) 102 115 115 140 145 125
Condenser Fan / Coil
Horsepower - RPM 1/6 - 840 1/6 - 815 1/6 - 840 1/6 - 815 ¼ - 830 ¼ - 830
RLA / LRA 1.1 / 1.7 1.1 / 1.7 1.1 / 1.7 1.1 / 1.7 1.6 / 3.0 1.5 / 3.0
Fan Diameter / # Fan Blades 22 / 3 22 / 3 22 / 3 22 / 3 22 / 3 22 / 4
Face Area (ft2) 15.2 13.4 14.2 13.4 17 17
Rows Deep/ Fins per Inch 1 / 19 1 / 24 1 / 22 1 / 24 1 / 22 1 / 24
Compressor
Quantity 1 1 1 1 1 1
Type Scroll Scroll Scroll Scroll Scroll Scroll
Stage Single Single Single Single Single Single
Electrical Data
Voltage/Phase/ Frequency 208/230-1-60 208/230-1-60 208/230-1-60
Compressor RLA / LRA 13.6 / 63 12.8 / 58.3 12.2 / 67 14.1 / 73 14.5 / 82 16.7 / 79
Indoor Blower FLA 1.5 1.5 2.4 1.86 2.4 1.86
Outdoor Fan RLA 1.1 1.1 1.1 1.1 1.5 1.5
Total Unit Amps 16.2 15.4 15.7 17.06 18.5 20.06
Min. Circuit Ampacity¹ 19.6 18.6 18.7 20.6 22.1 24.1
Max. Overcurrent Protection² 30 30 30 30 30 40
Ship Weight (lbs) 325 325 325 325 385 385
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require
larger wire sizes.
² Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.
Note: Always check the S&R plate for electrical data on the unit being installed.

SS-GPH13H www.goodmanmfg.com 3
Product Specifications

Specifications (cont.)
GPH13 GPH13 GPH13 GPH13 GPH13 GPH13
42H21AE 42H41** 48H21A* 48H41** 60H21A* 60H41**
Cooling Capacity
Total BTU/h 41,000 40,500 46,400 46,000 57,600 57,500
Sensible BTU/h 30,800 29,400 34,800 35,700 43,200 42,700
SEER / EER 13.0 / 11.3 13.0 / 11.0 13.0 / 10.8 13.0 / 11.0 13.0 / 10.9 13.0 / 11.0
Decibels 78 78 80 80 80 80
AHRI Numbers 735255 3414695 735096 3414696 735209 3414697
Heating Capacity
BTU/h (47°F) 38,000 38,000 45,000 44,500 54,400 54,500
C.O.P. (47°F) 3.6 3.6 3.3 3.6 3.4 3.6
BTU/h (17°F) 21,800 21,800 23,200 26,000 29,400 32,000
C.O.P. (17°F) 2.3 2.2 2.0 2.4 2.1 2.4
HSPF 7.8 7.8 7.7 7.7 7.7 7.7
Evaporator Motor
Type DD DD DD DD DD DD
Wheel (D x W) 10 x 8 10 x 8 10 x 8 10 x 8 11 x 8 11 x 8
Nominal Cooling CFM 1,410 1,410 1,585 1,585 1,850 1,850
RLA / LRA 3.9 / 4.9 2.87 / 4.9 3.9 / 4.9 2.87 / 4.9 6.0 / 8.0 5.8 / 8.0
No. of Speeds 3 3 3 3 3 3
Horsepower - RPM ½ - 1,075 ½ - 1,075 ½ - 1,075 ½ - 1,075 ¾ - 1,075 ¾ - 1,075
Evaporator Coil
Face Area (ft2) 6.2 6.2 6.2 6.2 7.0 7.0
Rows Deep / Fins per Inch 4 / 14 4 / 14 4 / 14 4 / 14 4 / 14 4 / 14
Filter Size (ft2) (2) 20 x 20 x 1 (2) 20 x 20 x 1 (2) 20 x 20 x 1 (2) 20 x 20 x 1 (2) 20 x 25 x 1 (2) 20 x 25 x 1
Drain Size (NPT) ¾” ¾” ¾” ¾” ¾” ¾”
Refrigerant Charge (oz.) 137 140 235 170 245 175
Condenser Fan / Coil
Horsepower - RPM ¼ - 1075 ¼ - 1075 ⅓ - 1075 ¼ - 1075 ⅓ - 1075 ¼ - 1075
RLA / LRA 1.6 / 3.3 1.4 / 2.9 2.4 / 5.2 1.4 / 2.9 2.4 / 5.2 1.4 / 2.9
Fan Diameter / # Fan Blades 22 / 3 22 / 4 22 / 4 22 / 4 22 / 4 22 / 4
Face Area (ft2) 17 17 19.1 19.1 19.1 19.1
Rows Deep/ Fins per Inch 1 / 24 1 / 24 2 / 16 2 / 16 2 / 16 2 / 16
Compressor
Quantity 1 1 1 1 1 1
Type Scroll Scroll Scroll Scroll Scroll Scroll
Stage Single Single Single Single Single Single
Electrical Data
Voltage/Phase/ Frequency 208/230-1-60 208/230-1-60 208/230-1-60
Compressor RLA / LRA 16.5 / 95 17.9 / 112 20.4 / 109 19.9 / 109 25.0 / 148 26.4 / 134
Indoor Blower FLA 3.9 2.87 3.9 2.87 6.0 5.8
Outdoor Fan RLA 1.6 1.4 2.4 1.4 2.4 1.4
Total Unit Amps 22.0 22.2 26.7 24.17 33.4 33.6
Min. Circuit Ampacity¹ 26.1 26.6 31.9 29.2 39.8 40.2
Max. Overcurrent Protection² 40 40 50 45 60 60
Ship Weight (lbs) 385 385 415 415 415 415
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require
larger wire sizes.
² Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.
Note: Always check the S&R plate for electrical data on the unit being installed.

4 www.goodmanmfg.com SS-GPH13H
Product Specifications

Airflow Data
E.S.P (In. of H₂O)
Model Speed Volts
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
CFM 630 580 545 500 470 - - -
Low 230
Watts 155 150 145 140 135 - - -
GPH13 CFM 865 815 770 720 670 610 555 -
Med 230
24H21AB Watts 230 220 215 210 200 195 185 -
CFM 1,190 1,130 1,060 990 935 845 770 680
High 230
Watts 370 360 345 335 320 310 290 275
CFM 680 640 590 555 505 440 340 -
Low 230
Watts 155 150 145 140 130 120 110 -
GPH13 CFM 895 855 815 755 700 630 545 390
Med 230
24H41** Watts 230 220 215 205 195 180 170 145
CFM 1,185 1,130 1,070 1,010 930 850 760 650
High 230
Watts 350 340 325 310 295 280 265 245
CFM 1,150 1,080 1,025 975 925 845 - -
Low 230
Watts 340 330 315 305 295 280 - -
GPH13 CFM 1,335 1,275 1,205 1,135 1,075 985 910 845
Med 230
30H21AB Watts 425 415 400 385 370 350 330 310
CFM 1,435 1,355 1,290 1,210 1,130 1,040 960 885
High 230
Watts 485 465 455 435 415 400 385 370
CFM 1,150 1,080 1,025 975 925 845 - -
Low 230
Watts 340 330 315 305 295 280 - -
GPH13 CFM 1,335 1,275 1,205 1,135 1,075 985 910 845
Med 230
30H41** Watts 425 415 400 385 370 350 330 310
CFM 1,435 1,355 1,290 1,210 1,130 1,040 960 885
High 230
Watts 485 465 455 435 415 400 385 370
CFM 1,180 1,125 1,075 1,020 955 875 655 -
Low 230
Watts 335 325 315 305 295 275 240 -
GPH13 CFM 1,350 1,280 1,205 1,130 1,050 985 910 845
Med 230
36H21AB Watts 435 420 405 385 375 350 330 310
CFM 1,450 1,370 1,290 1,205 1,130 1,040 960 885
High 230
Watts 495 480 465 440 425 400 385 370
CFM 1,180 1,125 1,075 1,020 955 875 655 -
Low 230
Watts 335 325 315 305 295 275 240 -
GPH13 CFM 1,350 1,280 1,205 1,130 1,050 985 910 845
Med 230
36H41** Watts 435 420 405 385 375 350 330 310
CFM 1,450 1,370 1,290 1,205 1,130 1,040 960 885
High 230
Watts 495 480 465 440 425 400 385 370
Notes:
1. Data shown is dry coil; wet coil pressure drop is approximate.
2. 0.1” H2O, for 2-row indoor coil; 0.2” H2O, for 3-row indoor coil; and 0.3” H2O, for 4-row indoor coil
3. Data shown does not include filter pressure drop, approx. 0.08” H2O.
4. ALL MODELS SHOULD RUN NO LESS THAN 350 CFM / TON, USE HIGHER SPEED TAP OR NEXT SIZE LARGER BLOWER ASM. See Repair
Parts list.
5. Reduce airflow by 2% for 208V operation.

SS-GPH13H www.goodmanmfg.com 5
Product Specifications

Airflow Data (cont.)


E.S.P (In. of H₂O)
Model Speed Volts
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
CFM 1,425 1,410 1,355 1,310 1,245 1,170 1,080 -
Low 230
Watts 450 445 430 420 405 390 370 -
GPH13 CFM 1,620 1,595 1,545 1,485 1,425 1,345 1,250 1,160
Med 230
42H21AB Watts 550 540 525 510 495 475 450 425
CFM 1,945 1,935 1,875 1,800 1,730 1,635 1,535 1,440
High 230
Watts 765 755 735 715 695 670 640 615
CFM 1,425 1,410 1,355 1,310 1,245 1,170 1,080 -
Low 230
Watts 450 445 430 420 405 390 370 -
GPH13 CFM 1,620 1,595 1,545 1,485 1,425 1,345 1,250 1,160
Med 230
42H41** Watts 550 540 525 510 495 475 450 425
CFM 1,945 1,935 1,875 1,800 1,730 1,635 1,535 1,440
High 230
Watts 765 755 735 715 695 670 640 615
CFM 1,425 1,410 1,355 1,310 1,245 1,170 1,080 -
Low 230
Watts 450 445 430 420 405 390 370 -
GPH13 CFM 1,720 1,660 1,585 1,520 1,460 1,365 1,270 -
Med 230
48H21AB Watts 560 555 540 530 520 490 470 -
CFM 2,110 2,060 1,980 1,895 1,795 1,705 1,590 1,500
High 230
Watts 785 780 765 745 720 705 665 625
CFM 1,425 1,410 1,355 1,310 1,245 1,170 1,080 -
Low 230
Watts 450 445 430 420 405 390 370 -
GPH13 CFM 1,720 1,660 1,585 1,520 1,460 1,365 1,270 -
Med 230
48H41** Watts 560 555 540 530 520 490 470 -
CFM 2,110 2,060 1,980 1,895 1,795 1,705 1,590 1,500
High 230
Watts 785 780 765 745 720 705 665 625
CFM 1,860 1,800 1,745 1,695 1,650 1,600 1,555 1,500
Low 230
Watts 410 425 440 455 470 480 495 500
GPH13 CFM 1,990 1,945 1,885 1,835 1,785 1,740 1,695 1,645
Med 230
60H21AB Watts 510 520 530 545 555 570 585 590
CFM 2,100 2,045 1,985 1,945 1,895 1,850 1,800 1,750
High 230
Watts 595 610 620 630 645 660 670 680
CFM 1,775 1,635 1,645 1,515 1,510 1,450 1,430 1,400
Low 230
Watts 395 420 435 445 455 465 470 475
GPH13 CFM 1,845 1,790 1,715 1,685 1,590 1,580 1,530 1,500
Med 230
60H41** Watts 490 505 520 535 550 560 570 575
CFM 2,025 1,900 1,840 1,780 1,725 1,650 1,620 1,580
High 230
Watts 575 595 620 630 645 655 660 670
Notes:
1. Data shown is dry coil; wet coil pressure drop is approximate.
2. 0.1” H2O, for 2-row indoor coil; 0.2” H2O, for 3-row indoor coil; and 0.3” H2O, for 4-row indoor coil
3. Data shown does not include filter pressure drop, approx. 0.08” H2O.
4. ALL MODELS SHOULD RUN NO LESS THAN 350 CFM / TON, USE HIGHER SPEED TAP OR NEXT SIZE LARGER BLOWER ASM. See Repair
Parts list.
5. Reduce airflow by 2% for 208V operation.

6 www.goodmanmfg.com SS-GPH13H
16
BTU OUTPUT vs TEMPERATURE RISE CHART

SS-GPH13H
100

600 CFM
90
Airflow Data (cont.)

700

80 800

900

70 1000
1100
1200
60
1400

1600
BLOWER PERFORMANCE DATA

50
1800
2000

TEMPERATURE RISE

www.goodmanmfg.com
40 2200
2400 CFM

30
FORMULAS
BTU OUTPUT = CFM x 1.08 x RISE
20 BTU OUTPUT
RISE = ÷ CFM
1.08

10
30 40 50 60 70 80 90 100 110 120 130 140 150

OUTPUT BTU/HR x 1000

7
Product Specifications
8
Outdoor Ambient Temperature
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
MBh 24.5 25.4 27.8 - 23.9 24.8 27.2 - 23.4 24.2 26.5 - 22.8 23.6 25.9 - 21.6 22.4 24.6 - 20.1 20.8 22.8 -
S/T 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.86 0.72 0.50 - 0.86 0.72 0.50 -
∆T 18 15 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 15 12 - 17 14 11 -
956 kW 1.86 1.90 1.95 - 2.00 2.04 2.10 - 2.12 2.16 2.23 - 2.23 2.27 2.35 - 2.32 2.37 2.44 - 2.40 2.45 2.53 -
Amps 6.6 6.7 7.0 - 7.1 7.3 7.5 - 7.8 7.9 8.2 - 8.3 8.5 8.8 - 8.8 9.1 9.4 - 9.4 9.6 9.9 -
Product Specifications

Hi PR 153 164 174 - 171 185 195 - 195 210 222 - 222 239 252 - 250 269 284 - 276 297 314 -
Lo PR 65 69 76 - 69 73 80 - 71 76 83 - 75 80 87 - 79 84 91 - 81 86 94 -
MBh 23.8 24.7 27.0 - 23.2 24.1 26.4 - 22.7 23.5 25.8 - 22.1 22.9 25.1 - 21.0 21.8 23.9 - 19.5 20.2 22.1 -
S/T 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.79 0.66 0.46 - 0.82 0.68 0.47 - 0.82 0.69 0.48 -
∆T 18 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 17 15 11 -
70 850 kW 1.84 1.88 1.94 - 1.98 2.02 2.09 - 2.10 2.15 2.21 - 2.21 2.26 2.33 - 2.30 2.35 2.42 - 2.38 2.43 2.51 -
Amps 6.5 6.7 6.9 - 7.1 7.2 7.5 - 7.7 7.9 8.1 - 8.2 8.4 8.7 - 8.8 9.0 9.3 - 9.3 9.5 9.8 -
Hi PR 151 163 172 - 170 183 193 - 193 208 219 - 220 237 250 - 247 266 281 - 273 294 311 -
Lo PR 64 68 75 - 68 72 79 - 71 75 82 - 74 79 86 - 78 83 90 - 80 86 93 -
MBh 22.0 22.8 24.9 - 21.4 22.2 24.3 - 20.9 21.7 23.8 - 20.4 21.2 23.2 - 19.4 20.1 22.0 - 18.0 18.6 20.4 -
S/T 0.69 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.61 0.43 - 0.76 0.63 0.44 - 0.79 0.66 0.46 - 0.80 0.66 0.46 -
∆T 19 16 12 - 19 16 13 - 19 16 13 - 19 17 13 - 19 16 12 - 18 15 12 -
744 kW 1.80 1.84 1.89 - 1.94 1.98 2.04 - 2.05 2.10 2.16 - 2.16 2.20 2.27 - 2.24 2.29 2.36 - 2.32 2.37 2.44 -
Expanded Cooling Data — GPH1324H21*

Amps 6.3 6.5 6.7 - 6.9 7.0 7.3 - 7.5 7.7 7.9 - 8.0 8.2 8.5 - 8.5 8.7 9.0 - 9.0 9.2 9.6 -
Hi PR 147 158 167 - 165 177 187 - 187 202 213 - 213 230 242 - 240 258 273 - 265 285 301 -
Lo PR 62 66 73 - 66 70 77 - 69 73 80 - 72 77 84 - 75 80 88 - 78 83 91 -

MBh 24.9 25.7 27.8 29.8 24.3 25.1 27.1 29.1 23.8 24.5 26.5 28.4 23.2 23.9 25.8 27.7 22.0 22.7 24.5 26.3 20.4 21.0 22.7 24.4
S/T 0.86 0.77 0.58 0.37 0.89 0.79 0.60 0.39 0.91 0.81 0.62 0.40 0.94 0.84 0.64 0.41 0.97 0.87 0.66 0.42 0.98 0.88 0.67 0.43
∆T 21 19 15 11 21 19 16 11 21 19 16 11 21 19 16 11 21 19 16 11 19 18 15 10

www.goodmanmfg.com
956 kW 1.87 1.91 1.97 2.03 2.01 2.05 2.12 2.19 2.14 2.18 2.25 2.32 2.24 2.29 2.37 2.44 2.34 2.39 2.46 2.55 2.42 2.47 2.55 2.63
Amps 6.6 6.8 7.0 7.3 7.2 7.4 7.6 7.9 7.8 8.0 8.3 8.6 8.4 8.6 8.9 9.2 8.9 9.1 9.5 9.8 9.5 9.7 10.0 10.4
Hi PR 154 166 175 183 173 186 197 205 197 212 224 233 224 241 255 266 252 272 287 299 279 300 317 331
Lo PR 66 70 76 81 69 74 81 86 72 77 84 89 76 81 88 94 79 84 92 98 82 87 95 102
MBh 24.2 24.9 27.0 28.9 23.6 24.3 26.3 28.3 23.1 23.7 25.7 27.6 22.5 23.2 25.1 26.9 21.4 22.0 23.8 25.6 19.8 20.4 22.1 23.7
S/T 0.82 0.73 0.55 0.36 0.85 0.76 0.57 0.37 0.87 0.78 0.59 0.38 0.90 0.80 0.61 0.39 0.93 0.83 0.63 0.40 0.94 0.84 0.63 0.41
∆T 21 20 16 11 22 20 16 11 22 20 16 11 22 20 16 11 21 20 16 11 20 18 15 10
75 850 kW 1.86 1.90 1.96 2.02 2.00 2.04 2.10 2.17 2.12 2.16 2.23 2.30 2.23 2.27 2.35 2.42 2.32 2.37 2.44 2.52 2.40 2.45 2.53 2.61
Amps 6.6 6.7 7.0 7.2 7.1 7.3 7.5 7.8 7.8 7.9 8.2 8.5 8.3 8.5 8.8 9.1 8.8 9.1 9.4 9.7 9.4 9.6 9.9 10.3
Hi PR 153 164 174 181 172 185 195 203 195 210 222 231 222 239 252 263 250 269 284 296 276 297 314 327
Lo PR 65 69 76 80 69 73 80 85 71 76 83 88 75 80 87 93 79 84 91 97 81 87 94 101
MBh 22.3 23.0 24.9 26.7 21.8 22.5 24.3 26.1 21.3 21.9 23.7 25.5 20.8 21.4 23.1 24.8 19.7 20.3 22.0 23.6 18.3 18.8 20.4 21.9
S/T 0.79 0.70 0.53 0.34 0.82 0.73 0.55 0.36 0.84 0.75 0.57 0.36 0.86 0.77 0.58 0.38 0.90 0.80 0.61 0.39 0.90 0.81 0.61 0.39
∆T 22 20 16 11 22 20 17 11 22 20 17 11 22 20 17 12 22 20 16 11 20 19 15 11
744 kW 1.82 1.85 1.91 1.97 1.95 1.99 2.05 2.12 2.07 2.11 2.18 2.25 2.17 2.22 2.29 2.36 2.26 2.31 2.38 2.46 2.34 2.39 2.47 2.55
Amps 6.4 6.6 6.8 7.0 6.9 7.1 7.3 7.6 7.5 7.7 8.0 8.3 8.1 8.3 8.5 8.9 8.6 8.8 9.1 9.4 9.1 9.3 9.6 10.0
Hi PR 148 160 168 176 166 179 189 197 189 204 215 224 215 232 245 255 242 261 275 287 268 288 304 317
Lo PR 63 67 73 78 67 71 77 82 69 74 80 86 73 77 85 90 76 81 89 94 79 84 92 98
IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions kW = Total system power

SS-GPH13H
High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)
Outdoor Ambient Temperature
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71

SS-GPH13H
MBh 25.4 25.9 27.7 29.6 24.8 25.3 27.0 28.9 24.2 24.7 26.4 28.2 23.6 24.1 25.8 27.5 22.4 22.9 24.5 26.2 20.8 21.2 22.7 24.2
S/T 0.94 0.88 0.72 0.54 1.00 0.91 0.74 0.56 1.00 0.94 0.76 0.57 1.00 0.97 0.79 0.59 1.00 1.00 0.82 0.61 1.00 1.00 0.82 0.62
∆T 23 22 19 15 24 22 19 15 23 22 19 15 23 22 19 16 22 22 19 15 20 20 18 14
956 kW 1.89 1.93 1.99 2.05 2.03 2.07 2.14 2.20 2.15 2.20 2.27 2.34 2.26 2.31 2.39 2.46 2.36 2.41 2.48 2.57 2.44 2.49 2.57 2.66
Amps 6.7 6.9 7.1 7.4 7.3 7.4 7.7 8.0 7.9 8.1 8.4 8.7 8.5 8.7 9.0 9.3 9.0 9.2 9.5 9.9 9.5 9.8 10.1 10.5
Hi PR 156 168 177 185 175 188 199 207 199 214 226 236 227 244 258 269 255 274 290 302 282 303 320 334
Lo PR 66 71 77 82 70 75 81 87 73 78 85 90 77 81 89 95 80 85 93 99 83 88 96 103
MBh 24.6 25.2 26.9 28.7 24.0 24.6 26.3 28.1 23.5 24.0 25.6 27.4 22.9 23.4 25.0 26.7 21.8 22.2 23.8 25.4 20.2 20.6 22.0 23.5
S/T 0.90 0.84 0.68 0.51 0.93 0.87 0.71 0.53 0.95 0.89 0.73 0.54 0.98 0.92 0.75 0.56 1.00 0.96 0.78 0.58 1.00 0.96 0.78 0.59
∆T 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 22 21 19 15
80 850 kW 1.87 1.91 1.97 2.03 2.01 2.06 2.12 2.19 2.14 2.18 2.25 2.32 2.24 2.29 2.37 2.44 2.34 2.39 2.46 2.55 2.42 2.47 2.55 2.63
Amps 6.6 6.8 7.0 7.3 7.2 7.4 7.6 7.9 7.8 8.0 8.3 8.6 8.4 8.6 8.9 9.2 8.9 9.1 9.5 9.8 9.5 9.7 10.0 10.4
Hi PR 154 166 175 183 173 186 197 205 197 212 224 234 224 241 255 266 252 272 287 299 279 300 317 331
Lo PR 66 70 76 81 69 74 81 86 72 77 84 89 76 81 88 94 79 84 92 98 82 87 95 102
MBh 22.7 23.2 24.8 26.5 22.2 22.7 24.2 25.9 21.7 22.1 23.7 25.3 21.1 21.6 23.1 24.7 20.1 20.5 21.9 23.4 18.6 19.0 20.3 21.7
S/T 0.86 0.81 0.66 0.49 0.90 0.84 0.68 0.51 0.92 0.86 0.70 0.52 0.95 0.89 0.72 0.54 0.98 0.92 0.75 0.56 0.99 0.93 0.76 0.57
∆T 24 23 20 16 25 24 20 16 25 24 20 16 25 24 21 16 24 23 20 16 23 22 19 15
744 kW 1.83 1.87 1.92 1.98 1.97 2.01 2.07 2.13 2.08 2.13 2.20 2.27 2.19 2.24 2.31 2.38 2.28 2.33 2.40 2.48 2.36 2.41 2.49 2.57
Amps 6.5 6.6 6.8 7.1 7.0 7.2 7.4 7.7 7.6 7.8 8.1 8.4 8.1 8.3 8.6 9.0 8.7 8.9 9.2 9.5 9.2 9.4 9.7 10.1
Hi PR 150 161 170 177 168 181 191 199 191 206 217 227 218 234 247 258 245 264 278 290 271 291 307 321
Lo PR 64 68 74 79 67 72 78 83 70 74 81 87 73 78 85 91 77 82 89 95 80 85 93 99
Expanded Cooling Data — GPH1324H21* (cont.)

MBh 25.8 26.3 27.5 29.4 25.2 25.7 26.9 28.7 24.6 25.1 26.3 28.0 24.0 24.5 25.6 27.3 22.8 23.2 24.3 26.0 21.1 21.5 22.5 24.1
S/T 0.98 0.95 0.86 0.70 1.00 0.98 0.89 0.72 1.00 1.00 0.91 0.74 1.00 1.00 0.94 0.76 1.00 1.00 0.98 0.79 1.00 1.00 0.98 0.80
∆T 24 24 23 20 24 24 23 20 24 24 23 20 23 24 23 20 22 22 23 20 20 21 21 18

www.goodmanmfg.com
956 kW 1.90 1.94 2.00 2.06 2.04 2.09 2.15 2.22 2.17 2.22 2.29 2.36 2.28 2.33 2.40 2.48 2.37 2.43 2.51 2.59 2.46 2.51 2.59 2.68
Amps 6.8 6.9 7.2 7.4 7.3 7.5 7.8 8.1 8.0 8.2 8.4 8.8 8.5 8.7 9.0 9.4 9.1 9.3 9.6 10.0 9.6 9.9 10.2 10.6
Hi PR 157 169 179 187 177 190 201 209 201 216 228 238 229 246 260 271 258 277 293 305 285 306 323 337
Lo PR 67 71 78 83 71 75 82 88 74 78 85 91 77 82 90 96 81 86 94 100 84 89 97 104
MBh 25.0 25.5 26.7 28.5 24.5 24.9 26.1 27.9 23.9 24.3 25.5 27.2 23.3 23.8 24.9 26.5 22.1 22.6 23.6 25.2 20.5 20.9 21.9 23.4
S/T 0.94 0.91 0.82 0.66 0.97 0.94 0.85 0.69 1.00 0.96 0.87 0.71 1.00 0.99 0.90 0.73 1.00 1.00 0.93 0.76 1.00 1.00 0.94 0.76
∆T 25 25 24 20 26 25 24 21 26 25 24 21 25 26 24 21 24 24 24 21 22 23 22 19
85 850 kW 1.89 1.93 1.99 2.05 2.03 2.07 2.14 2.20 2.15 2.20 2.27 2.34 2.26 2.31 2.39 2.46 2.36 2.41 2.48 2.57 2.44 2.49 2.57 2.66
Amps 6.7 6.9 7.1 7.4 7.3 7.4 7.7 8.0 7.9 8.1 8.4 8.7 8.5 8.7 9.0 9.3 9.0 9.2 9.5 9.9 9.5 9.8 10.1 10.5
Hi PR 156 168 177 185 175 188 199 207 199 214 226 236 227 244 258 269 255 274 290 302 282 303 320 334
Lo PR 66 71 77 82 70 75 81 87 73 78 85 90 77 81 89 95 80 85 93 99 83 88 96 103
MBh 23.1 23.6 24.7 26.3 22.6 23.0 24.1 25.7 22.0 22.5 23.5 25.1 21.5 21.9 23.0 24.5 20.4 20.8 21.8 23.3 18.9 19.3 20.2 21.6
S/T 0.91 0.87 0.79 0.64 0.94 0.91 0.82 0.66 0.96 0.93 0.84 0.68 0.99 0.96 0.86 0.70 1.00 0.99 0.90 0.73 1.00 1.00 0.91 0.73
∆T 26 25 24 21 26 26 24 21 26 26 24 21 26 26 25 21 25 26 24 21 23 24 23 20
744 kW 1.84 1.88 1.94 2.00 1.98 2.02 2.08 2.15 2.10 2.15 2.21 2.28 2.21 2.25 2.33 2.40 2.30 2.35 2.42 2.50 2.38 2.43 2.51 2.59
Amps 6.5 6.7 6.9 7.2 7.1 7.2 7.5 7.8 7.7 7.9 8.1 8.4 8.2 8.4 8.7 9.0 8.7 9.0 9.3 9.6 9.3 9.5 9.8 10.2
Hi PR 151 163 172 179 170 183 193 201 193 208 219 229 220 237 250 261 247 266 281 293 273 294 311 324
Lo PR 64 68 75 80 68 72 79 84 71 75 82 87 74 79 86 92 78 83 90 96 80 86 93 100
IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions kW = Total system power

9
High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)
Product Specifications
Outdoor Ambient Temperature

10
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
MBh 23.5 24.4 26.7 - 23.0 23.8 26.1 - 22.4 23.2 25.5 - 21.9 22.7 24.8 - 20.8 21.5 23.6 - 19.3 20.0 21.9 -
S/T 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.85 0.71 0.49 - 0.88 0.73 0.51 - 0.91 0.76 0.53 - 0.92 0.77 0.53 -
∆T 18 15 12 - 18 15 12 - 18 16 12 - 18 16 12 - 18 15 12 - 17 14 11 -
980 kW 1.71 1.74 1.80 - 1.83 1.87 1.93 - 1.95 1.99 2.05 - 2.05 2.09 2.16 - 2.13 2.18 2.25 - 2.20 2.25 2.32 -
Amps 7.2 7.4 7.6 - 7.7 7.9 8.1 - 8.3 8.5 8.8 - 8.8 9.0 9.3 - 9.3 9.5 9.8 - 9.8 10.0 10.3 -
Hi PR 242 260 275 - 271 292 308 - 308 332 350 - 351 378 399 - 395 425 449 - 436 470 496 -
Product Specifications

Lo PR 112 119 130 - 118 126 137 - 123 131 143 - 129 137 150 - 135 144 157 - 140 149 163 -
MBh 22.8 23.7 25.9 - 22.3 23.1 25.3 - 21.8 22.6 24.7 - 21.2 22.0 24.1 - 20.2 20.9 22.9 - 18.7 19.4 21.2 -
S/T 0.76 0.64 0.44 - 0.79 0.66 0.46 - 0.81 0.68 0.47 - 0.84 0.70 0.49 - 0.87 0.73 0.50 - 0.88 0.73 0.51 -
∆T 18 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -
70 875 kW 1.69 1.73 1.78 - 1.82 1.86 1.92 - 1.93 1.97 2.03 - 2.03 2.07 2.14 - 2.11 2.16 2.23 - 2.18 2.23 2.31 -
Amps 7.2 7.3 7.5 - 7.7 7.8 8.1 - 8.3 8.4 8.7 - 8.8 8.9 9.2 - 9.3 9.5 9.7 - 9.7 10.0 10.3 -
Hi PR 239 257 272 - 268 289 305 - 305 328 347 - 348 374 395 - 391 421 444 - 432 465 491 -
Lo PR 111 118 129 - 117 125 136 - 122 130 141 - 128 136 149 - 134 143 156 - 139 148 161 -
MBh 21.7 22.5 24.6 - 21.2 22.0 24.1 - 20.7 21.4 23.5 - 20.2 20.9 22.9 - 19.2 19.9 21.8 - 17.8 18.4 20.2 -
S/T 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.70 0.48 - 0.84 0.70 0.49 -
∆T 19 16 12 - 19 17 13 - 19 17 13 - 19 17 13 - 19 17 13 - 18 15 12 -
770 kW 1.67 1.70 1.75 - 1.79 1.83 1.89 - 1.90 1.94 2.00 - 2.00 2.04 2.10 - 2.08 2.12 2.19 - 2.15 2.20 2.27 -
Expanded Cooling Data — GPH1324H41*

Amps 7.1 7.2 7.4 - 7.6 7.7 7.9 - 8.1 8.3 8.5 - 8.6 8.8 9.1 - 9.1 9.3 9.6 - 9.6 9.8 10.1 -
Hi PR 234 252 266 - 263 283 299 - 299 322 340 - 341 367 387 - 383 412 436 - 423 456 481 -
Lo PR 109 116 126 - 115 122 133 - 119 127 139 - 125 133 146 - 131 140 153 - 136 145 158 -

MBh 23.9 24.6 26.7 28.6 23.4 24.1 26.0 27.9 22.8 23.5 25.4 27.3 22.2 22.9 24.8 26.6 21.1 21.8 23.6 25.3 19.6 20.2 21.8 23.4
S/T 0.91 0.81 0.62 0.40 0.94 0.84 0.64 0.41 0.97 0.87 0.66 0.42 1.00 0.89 0.68 0.44 1.00 0.93 0.70 0.45 1.00 0.94 0.71 0.46
∆T 20 19 15 11 21 19 16 11 21 19 16 11 21 19 16 11 20 19 16 11 18 18 14 10

www.goodmanmfg.com
980 kW 1.72 1.76 1.81 1.87 1.85 1.89 1.95 2.01 1.96 2.00 2.07 2.13 2.06 2.11 2.17 2.25 2.15 2.19 2.27 2.34 2.22 2.27 2.34 2.42
Amps 7.3 7.5 7.7 7.9 7.8 8.0 8.2 8.5 8.4 8.6 8.8 9.1 8.9 9.1 9.4 9.7 9.4 9.6 9.9 10.2 9.9 10.1 10.4 10.8
Hi PR 244 263 277 289 274 295 311 325 311 335 354 369 355 382 403 420 399 429 453 473 441 474 501 523
Lo PR 113 120 131 140 120 127 139 148 124 132 144 154 131 139 152 161 137 146 159 169 142 151 164 175
MBh 23.2 23.9 25.9 27.8 22.7 23.4 25.3 27.1 22.1 22.8 24.7 26.5 21.6 22.2 24.1 25.8 20.5 21.1 22.9 24.5 19.0 19.6 21.2 22.7
S/T 0.87 0.78 0.59 0.38 0.90 0.81 0.61 0.39 0.92 0.83 0.63 0.40 0.95 0.85 0.65 0.42 0.99 0.88 0.67 0.43 1.00 0.89 0.68 0.43
∆T 21 20 16 11 21 20 16 11 21 20 16 11 22 20 16 11 21 20 16 11 20 18 15 10
75 875 kW 1.71 1.74 1.80 1.85 1.83 1.87 1.93 1.99 1.95 1.99 2.05 2.12 2.05 2.09 2.16 2.23 2.13 2.18 2.25 2.32 2.20 2.25 2.32 2.40
Amps 7.2 7.4 7.6 7.8 7.7 7.9 8.1 8.4 8.3 8.5 8.8 9.0 8.8 9.0 9.3 9.6 9.3 9.5 9.8 10.2 9.8 10.0 10.3 10.7
Hi PR 242 260 275 286 271 292 308 321 308 332 350 365 351 378 399 416 395 425 449 468 437 470 496 517
Lo PR 112 119 130 139 118 126 138 146 123 131 143 152 129 138 150 160 135 144 157 168 140 149 163 173
MBh 22.1 22.7 24.6 26.4 21.5 22.2 24.0 25.8 21.0 21.7 23.4 25.2 20.5 21.1 22.9 24.5 19.5 20.1 21.7 23.3 18.1 18.6 20.1 21.6
S/T 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.38 0.88 0.79 0.60 0.39 0.91 0.82 0.62 0.40 0.95 0.85 0.64 0.41 0.96 0.85 0.65 0.42
∆T 22 20 17 11 22 20 17 12 22 20 17 12 22 21 17 12 22 20 17 11 21 19 16 11
770 kW 1.68 1.72 1.77 1.82 1.81 1.84 1.90 1.96 1.92 1.96 2.02 2.08 2.01 2.06 2.12 2.19 2.10 2.14 2.21 2.28 2.17 2.21 2.29 2.36
Amps 7.1 7.3 7.5 7.7 7.6 7.8 8.0 8.3 8.2 8.4 8.6 8.9 8.7 8.9 9.1 9.4 9.2 9.4 9.7 10.0 9.7 9.9 10.2 10.5
Hi PR 237 255 269 281 266 286 302 315 302 325 343 358 344 370 391 408 387 417 440 459 428 460 486 507
Lo PR 110 117 128 136 116 123 135 144 121 128 140 149 127 135 147 157 133 141 154 164 137 146 159 170
IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions kW = Total system power
High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)

SS-GPH13H
Outdoor Ambient Temperature
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71

SS-GPH13H
MBh 24.3 24.9 26.6 28.4 23.8 24.3 26.0 27.7 23.2 23.7 25.3 27.1 22.6 23.1 24.7 26.4 21.5 22.0 23.5 25.1 19.9 20.4 21.8 23.3
S/T 1.00 0.94 0.76 0.57 1.00 1.00 0.79 0.59 1.00 1.00 0.81 0.61 1.00 1.00 0.84 0.63 1.00 1.00 0.87 0.65 1.00 1.00 0.88 0.65
∆T 23 22 19 15 22 23 19 15 22 22 19 15 21 22 19 16 20 21 19 15 19 19 18 14
980 kW 1.73 1.77 1.82 1.88 1.86 1.90 1.96 2.03 1.98 2.02 2.08 2.15 2.08 2.12 2.19 2.26 2.17 2.21 2.28 2.36 2.24 2.29 2.36 2.44
Amps 7.4 7.5 7.7 8.0 7.9 8.0 8.3 8.5 8.5 8.6 8.9 9.2 9.0 9.2 9.4 9.8 9.5 9.7 10.0 10.3 10.0 10.2 10.5 10.9
Hi PR 246 265 280 292 277 298 314 328 315 339 357 373 358 386 407 425 403 434 458 478 445 479 506 528
Lo PR 114 122 133 141 121 129 140 149 126 134 146 155 132 140 153 163 138 147 161 171 143 152 166 177
MBh 23.6 24.1 25.8 27.6 23.1 23.6 25.2 26.9 22.5 23.0 24.6 26.3 22.0 22.5 19.2 25.7 20.9 21.3 22.8 24.4 19.3 19.8 21.1 22.6
S/T 0.95 0.89 0.73 0.54 0.99 0.93 0.75 0.56 1.00 0.95 0.77 0.58 1.00 0.98 0.80 0.60 1.00 1.00 0.83 0.62 1.00 1.00 0.84 0.62
∆T 24 23 20 16 24 23 20 16 24 23 20 16 23 23 20 16 22 22 20 16 20 21 19 15
80 875 kW 1.72 1.76 1.81 1.87 1.85 1.89 1.95 2.01 1.96 2.00 2.07 2.14 2.06 2.11 2.18 2.25 2.15 2.19 2.27 2.34 2.22 2.27 2.34 2.42
Amps 7.3 7.5 7.7 7.9 7.8 8.0 8.2 8.5 8.4 8.6 8.8 9.1 8.9 9.1 9.4 9.7 9.4 9.6 9.9 10.2 9.9 10.1 10.4 10.8
Hi PR 244 263 277 289 274 295 311 325 311 335 354 369 355 382 403 420 399 429 453 473 441 474 501 523
Lo PR 113 120 131 140 120 127 139 148 124 132 144 154 131 139 152 162 137 146 159 169 142 151 164 175
MBh 22.5 22.9 24.5 26.2 21.9 22.4 23.9 25.6 21.4 21.9 23.4 25.0 20.9 21.3 22.8 24.4 19.8 20.3 21.7 23.2 18.4 18.8 20.1 21.4
S/T 0.91 0.86 0.70 0.52 0.95 0.89 0.72 0.54 0.97 0.91 0.74 0.55 1.00 0.94 0.76 0.57 1.04 0.97 0.79 0.59 1.05 0.98 0.80 0.60
∆T 24 23 20 16 25 24 21 16 25 24 21 17 25 24 21 17 25 24 21 16 23 22 19 15
770 kW 1.69 1.73 1.78 1.84 1.82 1.86 1.92 1.98 1.93 1.97 2.03 2.10 2.03 2.07 2.14 2.21 2.11 2.16 2.23 2.30 2.18 2.23 2.31 2.38
Amps 7.2 7.3 7.5 7.8 7.7 7.8 8.1 8.3 8.3 8.4 8.7 9.0 8.8 8.9 9.2 9.5 9.3 9.5 9.7 10.1 9.7 10.0 10.3 10.6
Hi PR 239 257 272 283 268 289 305 318 305 328 347 362 348 374 395 412 391 421 444 464 432 465 491 512
Lo PR 111 118 129 137 117 125 136 145 122 130 141 151 128 136 149 158 134 143 156 166 139 148 161 172
Expanded Cooling Data — GPH1324H41* (cont.)

MBh 24.8 25.2 26.4 28.2 24.2 24.7 25.8 27.6 23.6 24.1 25.2 26.9 23.0 23.5 24.6 26.2 21.9 22.3 23.4 24.9 20.3 20.7 21.6 23.1
S/T 1.00 1.00 0.91 0.74 1.00 1.00 0.95 0.77 1.00 1.00 0.97 0.79 1.00 1.00 1.00 0.81 1.00 1.00 1.00 0.84 1.00 1.00 1.00 0.85
∆T 23 24 23 20 23 23 23 20 22 23 23 20 22 22 23 20 21 21 22 20 19 19 20 18

www.goodmanmfg.com
980 kW 1.75 1.78 1.84 1.90 1.88 1.92 1.98 2.04 1.99 2.04 2.10 2.17 2.10 2.14 2.21 2.28 2.18 2.23 2.30 2.38 2.26 2.31 2.38 2.46
Amps 7.4 7.6 7.8 8.0 7.9 8.1 8.3 8.6 8.5 8.7 9.0 9.3 9.0 9.2 9.5 9.8 9.6 9.8 10.1 10.4 10.1 10.3 10.6 11.0
Hi PR 249 268 283 295 279 301 317 331 318 342 361 377 362 389 411 429 407 438 463 482 450 484 511 533
Lo PR 115 123 134 143 122 130 142 151 127 135 147 157 133 142 155 165 140 149 162 173 144 154 168 179
MBh 24.0 24.5 25.7 27.4 23.5 23.9 25.1 26.8 22.9 23.4 24.5 26.1 22.4 22.8 23.9 25.5 21.2 21.7 22.7 24.2 19.7 20.1 21.0 22.4
S/T 1.00 0.96 0.87 0.71 1.00 1.00 0.90 0.73 1.00 1.00 0.92 0.75 1.00 1.00 0.95 0.77 1.00 1.00 0.99 0.80 1.00 1.00 1.00 0.81
∆T 25 25 23 20 25 25 24 21 24 25 24 21 24 24 24 21 22 23 24 20 21 21 22 19
85 875 kW 1.73 1.77 1.82 1.88 1.86 1.90 1.96 2.03 1.98 2.02 2.08 2.15 2.08 2.12 2.19 2.26 2.17 2.21 2.28 2.36 2.24 2.29 2.36 2.44
Amps 7.4 7.5 7.7 8.0 7.9 8.0 8.3 8.5 8.5 8.6 8.9 9.2 9.0 9.2 9.4 9.8 9.5 9.7 10.0 10.3 10.0 10.2 10.5 10.9
Hi PR 246 265 280 292 277 298 314 328 315 339 357 373 358 386 407 425 403 434 458 478 445 479 506 528
Lo PR 114 122 133 141 121 129 140 149 126 134 146 155 132 140 153 163 138 147 161 171 143 152 166 177
MBh 22.8 23.3 24.4 26.0 22.3 22.7 23.8 25.4 21.8 22.2 23.3 24.8 21.2 21.7 22.7 24.2 20.2 20.6 21.6 23.0 18.7 19.1 20.0 21.3
S/T 0.96 0.92 0.83 0.68 0.99 0.96 0.86 0.70 1.00 0.98 0.89 0.72 1.00 1.00 0.91 0.74 1.00 1.00 0.95 0.77 1.00 1.00 0.96 0.78
∆T 26 26 24 21 26 26 25 21 26 26 25 21 25 26 25 21 24 25 24 21 22 23 23 20
770 kW 1.71 1.74 1.80 1.85 1.83 1.87 1.93 1.99 1.95 1.99 2.05 2.12 2.05 2.09 2.16 2.23 2.13 2.18 2.25 2.32 2.20 2.25 2.32 2.40
Amps 7.2 7.4 7.6 7.8 7.7 7.9 8.1 8.4 8.3 8.5 8.8 9.0 8.8 9.0 9.3 9.6 9.3 9.5 9.8 10.2 9.8 10.0 10.3 10.7
Hi PR 242 260 275 286 271 292 308 321 308 332 350 365 351 378 399 416 395 425 449 468 436 470 496 517
Lo PR 112 119 130 139 118 126 137 146 123 131 143 152 129 137 150 160 135 144 157 168 140 149 163 173
IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions kW = Total system power

11
High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)
Product Specifications
Outdoor Ambient Temperature

12
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
MBh 28.0 29.0 31.8 - 27.4 28.4 31.1 - 26.7 27.7 30.3 - 26.1 27.0 29.6 - 24.8 25.7 28.1 - 22.9 23.8 26.1 -
S/T 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.86 0.72 0.50 - 0.86 0.72 0.50 -
∆T 16 14 11 - 17 14 11 - 17 14 11 - 17 15 11 - 17 14 11 - 15 13 10 -
1181 kW 2.06 2.10 2.17 - 2.22 2.26 2.33 - 2.35 2.41 2.48 - 2.48 2.53 2.61 - 2.58 2.64 2.72 - 2.67 2.73 2.82 -
Amps 7.5 7.7 8.0 - 8.2 8.4 8.6 - 8.9 9.1 9.4 - 9.5 9.7 10.1 - 10.1 10.4 10.7 - 10.7 11.0 11.4 -
Hi PR 156 168 177 - 175 188 199 - 199 214 226 - 226 244 257 - 255 274 290 - 281 303 320 -
Product Specifications

Lo PR 64 68 75 - 68 72 79 - 71 75 82 - 74 79 86 - 78 83 90 - 80 86 93 -
MBh 27.2 28.2 30.9 - 26.6 27.5 30.2 - 25.9 26.9 29.5 - 25.3 26.2 28.7 - 24.0 24.9 27.3 - 22.3 23.1 25.3 -
S/T 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.79 0.66 0.46 - 0.82 0.68 0.47 - 0.82 0.69 0.48 -
∆T 17 15 11 - 17 15 11 - 17 15 11 - 17 15 11 - 17 15 11 - 16 14 11 -
70 1050 kW 2.04 2.08 2.15 - 2.20 2.24 2.32 - 2.33 2.39 2.46 - 2.46 2.51 2.59 - 2.56 2.62 2.70 - 2.65 2.71 2.80 -
Amps 7.5 7.6 7.9 - 8.1 8.3 8.6 - 8.8 9.0 9.3 - 9.4 9.6 10.0 - 10.0 10.3 10.6 - 10.6 10.9 11.3 -
Hi PR 154 166 175 - 173 186 197 - 197 212 224 - 224 241 255 - 252 271 287 - 279 300 317 -
Lo PR 64 68 74 - 67 72 78 - 70 74 81 - 73 78 85 - 77 82 89 - 80 85 92 -
MBh 25.1 26.0 28.5 - 24.5 25.4 27.9 - 23.9 24.8 27.2 - 23.4 24.2 26.5 - 22.2 23.0 25.2 - 20.6 21.3 23.3 -
S/T 0.69 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.61 0.43 - 0.76 0.63 0.44 - 0.79 0.66 0.46 - 0.80 0.66 0.46 -
∆T 17 15 11 - 18 15 12 - 18 15 12 - 18 15 12 - 18 15 12 - 16 14 11 -
919 kW 1.99 2.04 2.10 - 2.14 2.19 2.26 - 2.28 2.33 2.40 - 2.40 2.45 2.53 - 2.50 2.55 2.63 - 2.58 2.64 2.73 -
Expanded Cooling Data — GPH1330H21*

Amps 7.3 7.4 7.7 - 7.9 8.0 8.3 - 8.5 8.8 9.1 - 9.1 9.4 9.7 - 9.7 10.0 10.3 - 10.3 10.6 11.0 -
Hi PR 150 161 170 - 168 181 191 - 191 206 217 - 217 234 247 - 245 263 278 - 270 291 307 -
Lo PR 62 66 72 - 65 69 76 - 68 72 79 - 71 76 83 - 75 79 87 - 77 82 90 -

MBh 28.5 29.3 31.8 34.1 27.8 28.7 31.0 33.3 27.2 28.0 30.3 32.5 26.5 27.3 29.5 31.7 25.2 25.9 28.1 30.1 23.3 24.0 26.0 27.9
S/T 0.86 0.77 0.58 0.37 0.89 0.79 0.60 0.39 0.91 0.81 0.62 0.40 0.94 0.84 0.64 0.41 0.97 0.87 0.66 0.42 0.98 0.88 0.67 0.43
∆T 19 17 14 10 19 18 15 10 19 18 15 10 19 18 15 10 19 18 14 10 18 16 13 9

www.goodmanmfg.com
1181 kW 2.07 2.12 2.18 2.25 2.23 2.28 2.35 2.43 2.37 2.43 2.50 2.59 2.50 2.55 2.64 2.72 2.60 2.66 2.75 2.84 2.69 2.75 2.84 2.94
Amps 7.6 7.8 8.0 8.4 8.2 8.4 8.7 9.1 9.0 9.2 9.5 9.9 9.6 9.8 10.2 10.6 10.2 10.5 10.8 11.3 10.8 11.1 11.5 12.0
Hi PR 157 169 179 187 177 190 201 209 201 216 228 238 229 246 260 271 257 277 292 305 284 306 323 337
Lo PR 65 69 75 80 69 73 80 85 71 76 83 88 75 80 87 93 78 84 91 97 81 86 94 100
MBh 27.7 28.5 30.8 33.1 27.0 27.8 30.1 32.3 26.4 27.2 29.4 31.6 25.7 26.5 28.7 30.8 24.5 25.2 27.3 29.2 22.7 23.3 25.2 27.1
S/T 0.82 0.73 0.55 0.36 0.85 0.76 0.57 0.37 0.87 0.78 0.59 0.38 0.90 0.80 0.61 0.39 0.93 0.83 0.63 0.40 0.94 0.84 0.63 0.41
∆T 20 18 15 10 20 18 15 10 20 18 15 10 20 19 15 11 20 18 15 10 19 17 14 10
75 1050 kW 2.06 2.10 2.17 2.24 2.22 2.26 2.34 2.41 2.35 2.41 2.48 2.57 2.48 2.53 2.61 2.70 2.58 2.64 2.73 2.82 2.67 2.73 2.82 2.92
Amps 7.5 7.7 8.0 8.3 8.2 8.4 8.6 9.0 8.9 9.1 9.4 9.8 9.5 9.7 10.1 10.5 10.1 10.4 10.7 11.2 10.7 11.0 11.4 11.8
Hi PR 156 168 177 185 175 188 199 207 199 214 226 236 227 244 257 268 255 274 290 302 282 303 320 334
Lo PR 64 68 75 80 68 72 79 84 71 75 82 87 74 79 86 92 78 83 90 96 80 86 93 99
MBh 25.5 26.3 28.5 30.5 24.9 25.7 27.8 29.8 24.4 25.1 27.1 29.1 23.8 24.5 26.5 28.4 22.6 23.2 25.2 27.0 20.9 21.5 23.3 25.0
S/T 0.79 0.70 0.53 0.34 0.82 0.73 0.55 0.36 0.84 0.75 0.57 0.36 0.86 0.77 0.58 0.38 0.90 0.80 0.61 0.39 0.90 0.81 0.61 0.39
∆T 20 19 15 10 20 19 15 11 20 19 15 11 21 19 15 11 20 19 15 11 19 17 14 10
919 kW 2.01 2.05 2.12 2.18 2.16 2.21 2.28 2.35 2.30 2.35 2.42 2.50 2.42 2.47 2.55 2.63 2.52 2.57 2.66 2.75 2.60 2.66 2.75 2.84
Amps 7.3 7.5 7.8 8.0 7.9 8.1 8.4 8.7 8.6 8.8 9.1 9.5 9.2 9.5 9.8 10.2 9.8 10.1 10.4 10.8 10.4 10.7 11.1 11.5
Hi PR 151 163 172 179 170 183 193 201 193 208 219 229 220 236 250 260 247 266 281 293 273 294 310 324
Lo PR 62 66 72 77 66 70 77 82 68 73 80 85 72 77 84 89 75 80 88 93 78 83 91 96
IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions kW = Total system power
High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)

SS-GPH13H
Outdoor Ambient Temperature
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71

SS-GPH13H
MBh 29.0 29.6 31.7 33.9 28.3 29.0 30.9 33.1 27.7 28.3 30.2 32.3 27.0 27.6 29.5 31.5 25.6 26.2 28.0 29.9 23.7 24.3 25.9 27.7
S/T 0.94 0.88 0.72 0.54 1.00 0.91 0.74 0.56 1.00 0.94 0.76 0.57 1.00 0.97 0.79 0.59 1.00 1.00 0.82 0.61 1.00 1.00 0.82 0.62
∆T 21 20 18 14 22 21 18 14 22 21 18 14 21 21 18 14 20 20 18 14 18 19 17 13
1181 kW 2.09 2.14 2.20 2.27 2.25 2.30 2.37 2.45 2.39 2.45 2.52 2.61 2.52 2.57 2.66 2.75 2.62 2.68 2.77 2.86 2.72 2.78 2.87 2.97
Amps 7.7 7.9 8.1 8.4 8.3 8.5 8.8 9.1 9.0 9.3 9.6 10.0 9.7 9.9 10.3 10.7 10.3 10.6 10.9 11.4 11.0 11.2 11.6 12.1
Hi PR 159 171 181 188 178 192 203 211 203 218 231 240 231 249 263 274 260 280 295 308 287 309 326 340
Lo PR 66 70 76 81 69 74 80 86 72 77 84 89 76 80 88 94 79 84 92 98 82 87 95 101
MBh 28.2 28.8 30.7 32.9 27.5 28.1 30.0 32.1 26.9 27.4 29.3 31.3 26.2 26.8 28.6 30.6 24.9 25.4 27.2 29.0 23.1 23.6 25.2 26.9
S/T 0.90 0.84 0.68 0.51 0.93 0.87 0.71 0.53 0.95 0.89 0.73 0.54 0.98 0.92 0.75 0.56 1.00 0.96 0.78 0.58 1.00 0.96 0.78 0.59
∆T 22 21 18 15 22 21 19 15 22 21 19 15 23 22 19 15 22 21 19 15 20 20 17 14
80 1050 kW 2.07 2.12 2.19 2.25 2.23 2.28 2.35 2.43 2.37 2.43 2.50 2.59 2.50 2.55 2.64 2.72 2.60 2.66 2.75 2.84 2.69 2.75 2.85 2.94
Amps 7.6 7.8 8.0 8.4 8.2 8.4 8.7 9.1 9.0 9.2 9.5 9.9 9.6 9.8 10.2 10.6 10.2 10.5 10.8 11.3 10.8 11.1 11.5 12.0
Hi PR 157 169 179 187 177 190 201 209 201 216 228 238 229 246 260 271 257 277 293 305 284 306 323 337
Lo PR 65 69 75 80 69 73 80 85 71 76 83 88 75 80 87 93 79 84 91 97 81 86 94 100
MBh 26.0 26.6 28.4 30.3 25.4 25.9 27.7 29.6 24.8 25.3 27.1 28.9 24.2 24.7 26.4 28.2 23.0 23.5 25.1 26.8 21.3 21.7 23.2 24.8
S/T 0.86 0.81 0.66 0.49 0.90 0.84 0.68 0.51 0.92 0.86 0.70 0.52 0.95 0.89 0.72 0.54 0.98 0.92 0.75 0.56 0.99 0.93 0.76 0.57
∆T 22 22 19 15 23 22 19 15 23 22 19 15 23 22 19 15 23 22 19 15 21 20 18 14
919 kW 2.03 2.07 2.13 2.20 2.18 2.23 2.30 2.37 2.32 2.37 2.44 2.52 2.44 2.49 2.57 2.66 2.54 2.59 2.68 2.77 2.63 2.68 2.77 2.87
Amps 7.4 7.6 7.8 8.1 8.0 8.2 8.5 8.8 8.7 8.9 9.2 9.6 9.3 9.6 9.9 10.3 9.9 10.2 10.5 10.9 10.5 10.8 11.2 11.6
Hi PR 153 164 174 181 171 184 195 203 195 210 221 231 222 239 252 263 250 269 284 296 276 297 313 327
Lo PR 63 67 73 78 67 71 77 82 69 74 80 86 73 77 84 90 76 81 88 94 79 84 91 97
Expanded Cooling Data — GPH1330H21* (cont.)

MBh 29.5 30.1 31.5 33.6 28.8 29.4 30.8 32.8 28.1 28.7 30.0 32.1 27.5 28.0 29.3 31.3 26.1 26.6 27.8 29.7 24.2 24.6 25.8 27.5
S/T 0.98 0.95 0.86 0.70 1.00 0.98 0.89 0.72 1.00 1.00 0.91 0.74 1.00 1.00 0.94 0.76 1.00 1.00 0.98 0.79 1.00 1.00 0.98 0.80
∆T 23 22 21 18 22 23 21 18 22 22 21 18 21 22 21 19 20 21 21 18 19 19 20 17

www.goodmanmfg.com
1181 kW 2.11 2.15 2.22 2.29 2.27 2.32 2.39 2.47 2.41 2.47 2.55 2.63 2.54 2.59 2.68 2.77 2.65 2.71 2.79 2.89 2.74 2.80 2.89 2.99
Amps 7.7 7.9 8.2 8.5 8.4 8.6 8.9 9.2 9.1 9.4 9.7 10.1 9.8 10.0 10.4 10.8 10.4 10.7 11.0 11.5 11.1 11.3 11.7 12.2
Hi PR 161 173 182 190 180 194 205 214 205 221 233 243 233 251 265 277 263 283 298 311 290 312 330 344
Lo PR 66 70 77 82 70 74 81 87 73 77 84 90 76 81 89 95 80 85 93 99 83 88 96 102
MBh 28.7 29.2 30.6 32.6 28.0 28.5 29.9 31.9 27.3 27.9 29.2 31.1 26.7 27.2 28.5 30.4 25.3 25.8 27.0 28.8 23.5 23.9 25.0 26.7
S/T 0.94 0.91 0.82 0.66 0.97 0.94 0.85 0.69 1.00 0.96 0.87 0.71 1.00 0.99 0.90 0.73 1.00 1.00 0.93 0.76 1.00 1.00 0.94 0.76
∆T 24 23 22 19 24 23 22 19 24 23 22 19 23 24 22 19 22 23 22 19 21 21 21 18
85 1050 kW 2.09 2.14 2.20 2.27 2.25 2.30 2.37 2.45 2.39 2.45 2.52 2.61 2.52 2.57 2.66 2.75 2.62 2.68 2.77 2.86 2.72 2.78 2.87 2.97
Amps 7.7 7.9 8.1 8.4 8.3 8.5 8.8 9.1 9.0 9.3 9.6 10.0 9.7 9.9 10.3 10.7 10.3 10.6 10.9 11.4 11.0 11.2 11.6 12.1
Hi PR 159 171 181 188 178 192 203 211 203 218 231 240 231 249 263 274 260 280 295 308 287 309 326 340
Lo PR 66 70 76 81 69 74 80 86 72 77 84 89 76 80 88 94 79 84 92 98 82 87 95 101
MBh 26.4 27.0 28.2 30.1 25.8 26.3 27.6 29.4 25.2 25.7 26.9 28.7 24.6 25.1 26.3 28.0 23.4 23.8 25.0 26.6 21.7 22.1 23.1 24.7
S/T 0.91 0.87 0.79 0.64 0.94 0.91 0.82 0.66 0.96 0.93 0.84 0.68 0.99 0.96 0.86 0.70 1.00 0.99 0.90 0.73 1.00 1.00 0.91 0.73
∆T 24 24 22 19 24 24 23 20 24 24 23 20 24 24 23 20 23 24 22 19 22 22 21 18
919 kW 2.04 2.08 2.15 2.22 2.20 2.24 2.32 2.39 2.33 2.39 2.46 2.54 2.46 2.51 2.59 2.68 2.56 2.62 2.70 2.79 2.65 2.71 2.80 2.89
Amps 7.5 7.6 7.9 8.2 8.1 8.3 8.6 8.9 8.8 9.0 9.3 9.7 9.4 9.6 10.0 10.4 10.0 10.3 10.6 11.0 10.6 10.9 11.3 11.7
Hi PR 154 166 175 183 173 186 197 205 197 212 224 233 224 241 255 266 252 271 287 299 279 300 317 330
Lo PR 64 68 74 79 67 72 78 83 70 74 81 86 73 78 85 91 77 82 89 95 80 85 92 98
IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions kW = Total system power

13
High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)
Product Specifications
Outdoor Ambient Temperature

14
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
MBh 27.6 28.6 31.4 - 27.0 28.0 30.7 - 26.3 27.3 29.9 - 25.7 26.6 29.2 - 24.4 25.3 27.7 - 22.6 23.4 25.7 -
S/T 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.85 0.71 0.49 - 0.87 0.73 0.51 - 0.91 0.76 0.52 - 0.91 0.76 0.53 -
∆T 17 15 11 - 17 15 11 - 17 15 11 - 18 15 11 - 17 15 11 - 16 14 11 -
1180 kW 2.03 2.07 2.13 - 2.18 2.22 2.29 - 2.31 2.36 2.43 - 2.43 2.48 2.56 - 2.53 2.58 2.66 - 2.61 2.67 2.75 -
Amps 8.7 8.8 9.1 - 9.3 9.4 9.7 - 9.9 10.1 10.4 - 10.5 10.8 11.1 - 11.1 11.4 11.7 - 11.7 12.0 12.3 -
Hi PR 247 265 280 - 277 298 314 - 315 339 358 - 358 386 407 - 403 434 458 - 446 479 506 -
Product Specifications

Lo PR 112 119 130 - 118 126 137 - 123 131 143 - 129 137 150 - 135 144 157 - 140 149 162 -
MBh 26.8 27.8 30.5 - 26.2 27.2 29.8 - 25.6 26.5 29.0 - 25.0 25.9 28.3 - 23.7 24.6 26.9 - 22.0 22.8 24.9 -
S/T 0.76 0.63 0.44 - 0.79 0.66 0.46 - 0.81 0.67 0.47 - 0.83 0.70 0.48 - 0.87 0.72 0.50 - 0.87 0.73 0.50 -
∆T 18 15 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -
70 1050 kW 2.01 2.05 2.12 - 2.16 2.21 2.27 - 2.29 2.34 2.41 - 2.41 2.46 2.54 - 2.51 2.56 2.64 - 2.59 2.65 2.73 -
Amps 8.6 8.8 9.0 - 9.2 9.4 9.6 - 9.9 10.1 10.4 - 10.4 10.7 11.0 - 11.0 11.3 11.6 - 11.6 11.9 12.2 -
Hi PR 244 263 277 - 274 295 311 - 312 335 354 - 355 382 403 - 399 430 454 - 441 475 501 -
Lo PR 111 118 129 - 117 124 136 - 121 129 141 - 128 136 148 - 134 142 155 - 138 147 161 -
MBh 24.8 25.7 28.1 - 24.2 25.1 27.5 - 23.6 24.5 26.8 - 23.0 23.9 26.2 - 21.9 22.7 24.9 - 20.3 21.0 23.0 -
S/T 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.47 - 0.83 0.70 0.48 - 0.84 0.70 0.49 -
∆T 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -
920 kW 1.97 2.01 2.07 - 2.11 2.15 2.22 - 2.24 2.28 2.36 - 2.35 2.40 2.48 - 2.45 2.50 2.58 - 2.53 2.58 2.66 -
Expanded Cooling Data — GPH1330H41*

Amps 8.4 8.6 8.8 - 9.0 9.1 9.4 - 9.6 9.8 10.1 - 10.2 10.4 10.7 - 10.8 11.0 11.3 - 11.3 11.6 11.9 -
Hi PR 237 255 269 - 266 286 302 - 302 325 343 - 344 370 391 - 387 417 440 - 428 460 486 -
Lo PR 107 114 125 - 113 121 132 - 118 125 137 - 124 132 144 - 130 138 151 - 134 143 156 -

MBh 28.1 28.9 31.3 33.6 27.4 28.3 30.6 32.8 26.8 27.6 29.9 32.0 26.1 26.9 29.1 31.3 24.8 25.6 27.7 29.7 23.0 23.7 25.6 27.5
S/T 0.91 0.81 0.61 0.39 0.94 0.84 0.64 0.41 0.96 0.86 0.65 0.42 0.99 0.89 0.67 0.43 1.00 0.92 0.70 0.45 1.00 0.93 0.70 0.45
∆T 20 18 15 10 20 18 15 10 20 19 15 10 20 19 15 11 19 18 15 10 18 17 14 10

www.goodmanmfg.com
1180 kW 2.04 2.09 2.15 2.22 2.20 2.24 2.31 2.38 2.33 2.38 2.45 2.53 2.45 2.50 2.58 2.66 2.55 2.60 2.69 2.77 2.63 2.69 2.78 2.87
Amps 8.7 8.9 9.1 9.4 9.3 9.5 9.8 10.1 10.0 10.2 10.5 10.9 10.6 10.8 11.2 11.5 11.2 11.5 11.8 12.2 11.8 12.1 12.4 12.9
Hi PR 249 268 283 295 280 301 318 331 318 342 361 377 362 390 411 429 407 438 463 483 450 484 511 533
Lo PR 113 120 131 140 119 127 139 148 124 132 144 153 130 139 151 161 136 145 158 169 141 150 164 175
MBh 27.3 28.1 30.4 32.6 26.6 27.4 29.7 31.9 26.0 26.8 29.0 31.1 25.4 26.13 28.3 30.4 24.1 24.8 26.9 28.8 22.3 23.0 24.9 26.7
S/T 0.86 0.77 0.58 0.38 0.90 0.80 0.61 0.39 0.92 0.82 0.62 0.40 0.95 0.85 0.64 0.41 0.98 0.88 0.67 0.43 0.99 0.89 0.67 0.43
∆T 21 19 16 11 21 19 16 11 21 19 16 11 21 19.39 16 11 21 19 16 11 19 18 15 10
75 1050 kW 2.03 2.07 2.13 2.20 2.18 2.22 2.29 2.36 2.31 2.36 2.43 2.51 2.43 2.48 2.56 2.64 2.53 2.58 2.66 2.75 2.61 2.67 2.76 2.85
Amps 8.7 8.8 9.1 9.4 9.3 9.4 9.7 10.0 9.9 10.1 10.4 10.8 10.5 10.76 11.1 11.4 11.1 11.4 11.7 12.1 11.7 12.0 12.3 12.7
Hi PR 247 265 280 292 277 298 315 328 315 339 358 373 358 385.79 407 425 403 434 458 478 446 480 506 528
Lo PR 112 119 130 138 118 126 137 146 123 131 143 152 129 137.16 150 159 135 144 157 167 140 149 162 173
MBh 25.2 25.9 28.1 30.1 24.6 25.3 27.4 29.4 24.0 24.7 26.8 28.7 23.4 24.1 26.1 28.0 22.3 22.9 24.8 26.6 20.6 21.2 23.0 24.7
S/T 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.38 0.89 0.79 0.60 0.39 0.91 0.82 0.62 0.40 0.95 0.85 0.64 0.41 0.96 0.86 0.65 0.42
∆T 21 19 16 11 21 20 16 11 21 20 16 11 21 20 16 11 21 19 16 11 20 18 15 10
920 kW 1.98 2.02 2.08 2.15 2.13 2.17 2.24 2.31 2.26 2.30 2.37 2.45 2.37 2.42 2.50 2.58 2.47 2.52 2.60 2.68 2.55 2.60 2.69 2.78
Amps 8.5 8.6 8.9 9.1 9.0 9.2 9.5 9.8 9.7 9.9 10.2 10.5 10.3 10.5 10.8 11.2 10.9 11.1 11.4 11.8 11.4 11.7 12.0 12.4
Hi PR 239 257 272 284 268 289 305 318 305 329 347 362 348 374 395 412 391 421 445 464 432 465 491 512
Lo PR 108 115 126 134 115 122 133 142 119 127 138 147 125 133 145 155 131 139 152 162 136 144 157 168
IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions kW = Total system power
High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)

SS-GPH13H
Outdoor Ambient Temperature
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71

SS-GPH13H
MBh 28.6 29.2 31.2 33.4 27.9 28.5 30.5 32.6 27.3 27.9 29.8 31.8 26.6 27.2 29.0 31.1 25.3 25.8 27.6 29.5 23.4 23.9 25.6 27.3
S/T 1.00 0.93 0.76 0.57 1.00 0.97 0.79 0.59 1.00 1.00 0.81 0.60 1.00 1.00 0.83 0.62 1.00 1.00 0.86 0.65 1.00 1.00 0.87 0.65
∆T 22 21 18 15 22 21 19 15 21 22 19 15 21 21 19 15 20 20 19 15 18 19 17 14
1180 kW 2.06 2.10 2.17 2.23 2.21 2.26 2.33 2.40 2.35 2.40 2.47 2.55 2.47 2.52 2.60 2.68 2.57 2.62 2.71 2.80 2.66 2.71 2.80 2.89
Amps 8.8 9.0 9.2 9.5 9.4 9.6 9.9 10.2 10.1 10.3 10.6 11.0 10.7 10.9 11.3 11.6 11.3 11.6 11.9 12.3 11.9 12.2 12.5 13.0
Hi PR 252 271 286 298 282 304 321 335 321 346 365 381 366 394 416 433 411 443 468 488 455 489 517 539
Lo PR 114 121 132 141 120 128 140 149 125 133 145 155 132 140 153 163 138 147 160 171 143 152 166 176
MBh 27.8 28.4 30.3 32.4 27.1 27.7 29.6 31.7 26.5 27.1 28.9 30.9 25.8 26.4 28.2 30.1 24.5 25.1 26.8 28.6 22.7 23.2 24.8 26.5
S/T 0.95 0.89 0.72 0.54 0.98 0.92 0.75 0.56 1.00 0.94 0.77 0.57 1.00 0.97 0.79 0.59 1.00 1.00 0.82 0.62 1.00 1.00 0.83 0.62
∆T 23 22 19 15 23 22 19 16 23 22 19 16 23 23 20 16 21 22 19 15 20 20 18 14
80 1050 kW 2.04 2.09 2.15 2.22 2.20 2.24 2.31 2.38 2.33 2.38 2.45 2.53 2.45 2.50 2.58 2.66 2.55 2.60 2.69 2.77 2.63 2.69 2.78 2.87
Amps 8.7 8.9 9.2 9.4 9.3 9.5 9.8 10.1 10.0 10.2 10.5 10.9 10.6 10.8 11.2 11.5 11.2 11.5 11.8 12.2 11.8 12.1 12.4 12.9
Hi PR 249 268 283 295 280 301 318 331 318 342 361 377 362 390 412 429 407 438 463 483 450 484 511 533
Lo PR 113 120 131 140 119 127 139 148 124 132 144 153 130 139 151 161 136 145 159 169 141 150 164 175
MBh 25.6 26.2 28.0 29.9 25.0 25.6 27.3 29.2 24.4 25.0 26.7 28.5 23.8 24.4 26.0 27.8 22.7 23.1 24.7 26.4 21.0 21.4 22.9 24.5
S/T 0.91 0.86 0.70 0.52 0.95 0.89 0.72 0.54 0.97 0.91 0.74 0.55 1.00 0.94 0.76 0.57 1.04 0.98 0.79 0.59 1.05 0.98 0.80 0.60
∆T 23 22 19 16 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 22 21 18 15
920 kW 2.00 2.04 2.10 2.16 2.14 2.19 2.26 2.33 2.27 2.32 2.39 2.47 2.39 2.44 2.52 2.60 2.49 2.54 2.62 2.71 2.57 2.62 2.71 2.80
Amps 8.5 8.7 8.9 9.2 9.1 9.3 9.6 9.9 9.8 10.0 10.3 10.6 10.4 10.6 10.9 11.3 10.9 11.2 11.5 11.9 11.5 11.8 12.1 12.5
Hi PR 242 260 275 286 271 292 308 321 308 332 350 366 351 378 399 416 395 425 449 468 437 470 496 517
Lo PR 110 117 127 135 116 123 134 143 120 128 140 149 126 134 147 156 132 141 154 164 137 146 159 169
Expanded Cooling Data — GPH1330H41* (cont.)

MBh 29.1 29.7 31.1 33.1 28.4 29.0 30.3 32.4 27.7 28.3 29.6 31.6 27.1 27.6 28.9 30.8 25.7 26.2 27.5 29.3 23.8 24.3 25.4 27.1
S/T 1.00 1.00 0.91 0.74 1.00 1.00 0.94 0.76 1.00 1.00 0.96 0.78 1.00 1.00 0.99 0.81 1.00 1.00 1.00 0.84 1.00 1.00 1.00 0.84
∆T 23 23 22 19 22 23 22 19 22 22 22 19 21 21 22 19 20 20 21 19 19 19 20 18

www.goodmanmfg.com
1180 kW 2.08 2.12 2.18 2.25 2.23 2.28 2.35 2.42 2.37 2.42 2.49 2.57 2.49 2.54 2.62 2.71 2.59 2.64 2.73 2.82 2.68 2.74 2.82 2.92
Amps 8.9 9.0 9.3 9.6 9.5 9.7 9.9 10.3 10.2 10.4 10.7 11.1 10.8 11.0 11.3 11.7 11.4 11.7 12.0 12.4 12.0 12.3 12.6 13.1
Hi PR 254 273 289 301 285 307 324 338 324 349 369 384 369 398 420 438 416 447 472 493 459 494 522 544
Lo PR 115 123 134 142 122 129 141 151 126 135 147 156 133 141 154 164 139 148 162 172 144 153 167 178
MBh 28.3 28.8 30.2 32.2 27.6 28.1 29.5 31.4 26.9 27.5 28.8 30.7 26.3 26.8 28.1 29.9 25.0 25.5 26.7 28.4 23.1 23.6 24.7 26.3
S/T 0.99 0.96 0.86 0.70 1.00 0.99 0.90 0.73 1.00 1.00 0.92 0.75 1.00 1.00 0.95 0.77 1.00 1.00 0.98 0.80 1.00 1.00 0.99 0.81
∆T 25 24 23 20 24 24 23 20 24 24 23 20 23 23 23 20 22 22 23 20 20 21 21 19
85 1050 kW 2.06 2.10 2.17 2.23 2.21 2.26 2.33 2.40 2.35 2.40 2.47 2.55 2.47 2.52 2.60 2.68 2.57 2.62 2.71 2.80 2.66 2.71 2.80 2.89
Amps 8.8 9.0 9.2 9.5 9.4 9.6 9.9 10.2 10.1 10.3 10.6 11.0 10.7 10.9 11.3 11.6 11.3 11.6 11.9 12.3 11.9 12.2 12.5 13.0
Hi PR 252 271 286 298 282 304 321 335 321 346 365 381 366 394 416 433 411 443 468 488 455 489 517 539
Lo PR 114 121 132 141 120 128 140 149 125 133 145 155 132 140 153 163 138 147 160 171 143 152 166 176
MBh 26.1 26.6 27.8 29.7 25.5 26.0 27.2 29.0 24.9 25.3 26.5 28.3 24.3 24.7 25.9 27.6 23.0 23.5 24.6 26.2 21.3 21.8 22.8 24.3
S/T 0.96 0.92 0.83 0.68 0.99 0.96 0.86 0.70 1.00 0.98 0.89 0.72 1.00 1.00 0.91 0.74 1.00 1.00 0.95 0.77 1.00 1.00 0.96 0.78
∆T 25 25 23 20 25 25 23 20 25 25 24 20 24 25 24 20 23 23 23 20 21 22 22 19
920 kW 2.01 2.05 2.12 2.18 2.16 2.21 2.27 2.35 2.29 2.34 2.41 2.49 2.41 2.46 2.54 2.62 2.51 2.56 2.64 2.73 2.59 2.65 2.73 2.82
Amps 8.6 8.8 9.0 9.3 9.2 9.4 9.6 9.9 9.9 10.1 10.4 10.7 10.4 10.7 11.0 11.3 11.0 11.3 11.6 12.0 11.6 11.9 12.2 12.6
Hi PR 244 263 277 289 274 295 311 325 311 335 354 369 355 382 403 420 399 430 454 473 441 475 501 523
Lo PR 111 118 128 137 117 124 136 145 121 129 141 150 128 136 148 158 134 142 155 165 138 147 161 171
IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions kW = Total system power

15
High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)
Product Specifications
Outdoor Ambient Temperature

16
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
MBh 34.3 35.5 38.9 - 33.5 34.7 38.0 - 32.7 33.9 37.1 - 31.9 33.1 36.2 - 30.3 31.4 34.4 - 28.1 29.1 31.9 -
S/T 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.86 0.72 0.50 - 0.86 0.72 0.50 -
∆T 17 15 11 - 17 15 11 - 17 15 11 - 17 15 11 - 17 15 11 - 16 14 10 -
1406 kW 2.35 2.40 2.48 - 2.54 2.59 2.68 - 2.70 2.76 2.86 - 2.85 2.91 3.01 - 2.97 3.04 3.14 - 3.08 3.15 3.25 -
Amps 9.3 9.5 9.8 - 10.0 10.3 10.7 - 11.0 11.2 11.6 - 11.7 12.0 12.4 - 12.5 12.8 13.3 - 13.3 13.6 14.1 -
Hi PR 150 161 170 - 168 181 191 - 191 206 217 - 218 234 247 - 245 264 278 - 271 291 308 -
Product Specifications

Lo PR 63 67 73 - 66 71 77 - 69 73 80 - 72 77 84 - 76 81 88 - 79 84 91 -
MBh 33.3 34.5 37.8 - 32.5 33.7 36.9 - 31.7 32.9 36.1 - 31.0 32.1 35.2 - 29.4 30.5 33.4 - 27.3 28.3 31.0 -
S/T 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.79 0.66 0.46 - 0.82 0.68 0.47 - 0.82 0.69 0.48 -
∆T 18 15 12 - 18 15 12 - 18 15 12 - 18 16 12 - 18 15 12 - 17 14 11 -
70 1250 kW 2.33 2.38 2.46 - 2.52 2.57 2.66 - 2.68 2.74 2.83 - 2.82 2.89 2.98 - 2.95 3.01 3.11 - 3.05 3.12 3.23 -
Amps 9.2 9.4 9.7 - 10.0 10.2 10.6 - 10.9 11.1 11.5 - 11.6 11.9 12.3 - 12.4 12.7 13.2 - 13.2 13.5 14.0 -
Hi PR 148 160 169 - 166 179 189 - 189 204 215 - 216 232 245 - 243 261 276 - 268 288 305 -
Lo PR 62 66 72 - 66 70 76 - 68 73 79 - 72 76 83 - 75 80 87 - 78 83 90 -
MBh 30.7 31.9 34.9 - 30.0 31.1 34.1 - 29.3 30.4 33.3 - 28.6 29.6 32.5 - 27.2 28.2 30.8 - 25.2 26.1 28.6 -
S/T 0.69 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.61 0.43 - 0.76 0.63 0.44 - 0.79 0.66 0.46 - 0.80 0.66 0.46 -
∆T 18 15 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -
1094 kW 2.28 2.33 2.40 - 2.46 2.51 2.59 - 2.61 2.67 2.76 - 2.75 2.81 2.91 - 2.87 2.93 3.03 - 2.97 3.04 3.14 -
Expanded Cooling Data — GPH1336H21*

Amps 8.9 9.1 9.5 - 9.7 9.9 10.3 - 10.5 10.8 11.2 - 11.3 11.6 12.0 - 12.0 12.3 12.8 - 12.8 13.1 13.6 -
Hi PR 144 155 164 - 161 174 183 - 184 198 209 - 209 225 238 - 235 253 267 - 260 280 295 -
Lo PR 60 64 70 - 64 68 74 - 66 70 77 - 70 74 81 - 73 78 85 - 75 80 88 -

MBh 34.9 35.9 38.9 41.7 34.1 35.1 38.0 40.7 33.3 34.2 37.1 39.8 32.4 33.4 36.2 38.8 30.8 31.7 34.4 36.9 28.6 29.4 31.8 34.2
S/T 0.86 0.77 0.58 0.37 0.89 0.79 0.60 0.39 0.91 0.81 0.62 0.40 0.94 0.84 0.64 0.41 0.97 0.87 0.66 0.42 0.98 0.88 0.67 0.43
∆T 20 18 15 10 20 18 15 10 20 18 15 10 20 18 15 10 20 18 15 10 18 17 14 10

www.goodmanmfg.com
1406 kW 2.37 2.42 2.50 2.59 2.56 2.62 2.70 2.79 2.73 2.79 2.88 2.98 2.87 2.94 3.04 3.14 3.00 3.06 3.17 3.28 3.10 3.17 3.28 3.40
Amps 9.4 9.6 9.9 10.3 10.1 10.4 10.8 11.2 11.1 11.3 11.7 12.2 11.8 12.1 12.6 13.1 12.6 13.0 13.4 13.9 13.4 13.8 14.2 14.8
Hi PR 151 163 172 179 170 183 193 201 193 208 219 229 220 237 250 261 247 266 281 293 273 294 311 324
Lo PR 63 67 74 78 67 71 78 83 70 74 81 86 73 78 85 91 77 82 89 95 79 84 92 98
MBh 33.9 34.9 37.7 40.5 33.1 34.1 36.9 39.6 32.3 33.2 36.0 38.6 31.5 32.4 35.1 37.7 29.9 30.8 33.3 35.8 27.7 28.5 30.9 33.2
S/T 0.82 0.73 0.55 0.36 0.85 0.76 0.57 0.37 0.87 0.78 0.59 0.38 0.90 0.80 0.61 0.39 0.93 0.83 0.63 0.40 0.94 0.84 0.63 0.41
∆T 20 19 15 11 21 19 16 11 21 19 16 11 21 19 16 11 20 19 15 11 19 18 14 10
75 1250 kW 2.35 2.40 2.48 2.56 2.54 2.60 2.68 2.77 2.70 2.76 2.86 2.95 2.85 2.91 3.01 3.11 2.97 3.04 3.14 3.25 3.08 3.15 3.25 3.37
Amps 9.3 9.5 9.8 10.2 10.1 10.3 10.7 11.1 11.0 11.2 11.6 12.1 11.7 12.0 12.5 12.9 12.5 12.8 13.3 13.8 13.3 13.6 14.1 14.7
Hi PR 150 161 170 178 168 181 191 199 191 206 217 227 218 234 248 258 245 264 278 290 271 291 308 321
Lo PR 63 67 73 78 66 71 77 82 69 73 80 85 72 77 84 90 76 81 88 94 79 84 91 97
MBh 31.3 32.2 34.8 37.4 30.5 31.4 34.0 36.5 29.8 30.7 33.2 35.6 29.1 29.9 32.4 34.8 27.6 28.4 30.8 33.0 25.6 26.3 28.5 30.6
S/T 0.79 0.70 0.53 0.34 0.82 0.73 0.55 0.36 0.84 0.75 0.57 0.36 0.86 0.77 0.58 0.38 0.90 0.80 0.61 0.39 0.90 0.81 0.61 0.39
∆T 21 19 16 11 21 19 16 11 21 19 16 11 21 19 16 11 21 19 16 11 19 18 15 10
1094 kW 2.30 2.35 2.42 2.50 2.48 2.53 2.61 2.70 2.64 2.69 2.78 2.88 2.78 2.84 2.93 3.03 2.89 2.96 3.06 3.17 3.00 3.07 3.17 3.28
Amps 9.0 9.2 9.5 9.9 9.8 10.0 10.4 10.8 10.6 10.9 11.3 11.7 11.4 11.7 12.1 12.6 12.2 12.5 12.9 13.4 12.9 13.2 13.7 14.2
Hi PR 145 156 165 172 163 176 185 193 185 200 211 220 211 227 240 250 238 256 270 282 263 283 298 311
Lo PR 61 65 71 75 64 68 75 80 67 71 78 83 70 75 82 87 74 78 86 91 76 81 88 94
IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions kW = Total system power
High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)

SS-GPH13H
Outdoor Ambient Temperature
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71

SS-GPH13H
MBh 35.5 36.3 38.8 41.4 34.7 35.4 37.9 40.5 33.8 34.6 37.0 39.5 33.0 33.7 36.1 38.5 31.4 32.1 34.2 36.6 29.1 29.7 31.7 33.9
S/T 0.94 0.88 0.72 0.54 1.00 0.91 0.74 0.56 1.00 0.94 0.76 0.57 1.00 0.97 0.79 0.59 1.00 1.00 0.82 0.61 1.00 1.00 0.82 0.62
∆T 22 21 18 15 23 21 18 15 22 21 18 15 22 21 19 15 21 21 18 15 19 19 17 14
1406 kW 2.39 2.44 2.52 2.61 2.58 2.64 2.73 2.82 2.75 2.81 2.90 3.00 2.90 2.96 3.06 3.17 3.02 3.09 3.20 3.31 3.13 3.20 3.31 3.43
Amps 9.4 9.7 10.0 10.4 10.2 10.5 10.9 11.3 11.2 11.4 11.8 12.3 12.0 12.3 12.7 13.2 12.8 13.1 13.5 14.1 13.5 13.9 14.4 14.9
Hi PR 153 165 174 181 172 185 195 203 195 210 222 231 222 239 253 263 250 269 284 296 276 297 314 327
Lo PR 64 68 74 79 68 72 79 84 70 75 82 87 74 79 86 91 77 82 90 96 80 85 93 99
MBh 34.5 35.2 37.6 40.2 33.7 34.4 36.8 39.3 32.9 33.6 35.9 38.4 32.1 32.8 35.0 37.4 30.5 31.1 33.3 35.5 28.2 28.8 30.8 32.9
S/T 0.90 0.84 0.68 0.51 0.93 0.87 0.71 0.53 0.95 0.89 0.73 0.54 0.98 0.92 0.75 0.56 1.00 0.96 0.78 0.58 1.00 0.96 0.78 0.59
∆T 23 22 19 15 23 22 19 15 23 22 19 15 23 22 19 15 22 22 19 15 21 20 18 14
80 1250 kW 2.37 2.42 2.50 2.59 2.56 2.62 2.70 2.79 2.73 2.79 2.88 2.98 2.87 2.94 ## 3.14 3.00 3.06 3.17 3.28 3.10 3.17 3.28 3.40
Amps 9.4 9.6 9.9 10.3 10.1 10.4 10.8 11.2 11.1 11.3 11.7 12.2 11.9 12.2 12.6 13.1 12.6 13.0 13.4 13.9 13.4 13.8 14.2 14.8
Hi PR 151 163 172 179 170 183 193 201 193 208 220 229 220 237 250 261 248 266 281 293 273 294 311 324
Lo PR 63 68 74 78 67 71 78 83 70 74 81 86 73 78 85 91 77 82 89 95 79 84 92 98
MBh 31.8 32.5 34.7 37.1 31.1 31.7 33.9 36.3 30.3 31.0 33.1 35.4 29.6 30.2 32.3 34.5 28.1 28.7 30.7 32.8 26.0 26.6 28.4 30.4
S/T 0.86 0.81 0.66 0.49 0.90 0.84 0.68 0.51 0.92 0.86 0.70 0.52 0.95 0.89 0.72 0.54 0.98 0.92 0.75 0.56 0.99 0.93 0.76 0.57
∆T 23 22 19 15 23 22 19 16 23 22 20 16 24 23 20 16 23 22 19 15 22 21 18 14
1094 kW 2.31 2.36 2.44 2.52 2.50 2.55 2.64 2.72 2.66 2.72 2.81 2.90 2.80 2.86 2.96 3.06 2.92 2.99 3.09 3.19 3.02 3.09 3.20 3.31
Amps 9.1 9.3 9.6 10.0 9.9 10.1 10.5 10.9 10.7 11.0 11.4 11.8 11.5 11.8 12.2 12.7 12.3 12.6 13.0 13.5 13.0 13.4 13.8 14.4
Hi PR 147 158 167 174 165 177 187 195 187 202 213 222 213 230 243 253 240 258 273 285 265 285 301 314
Lo PR 62 65 71 76 65 69 76 80 68 72 78 84 71 76 82 88 74 79 86 92 77 82 89 95
Expanded Cooling Data — GPH1336H21* (cont.)

MBh 36.1 36.8 38.6 41.1 35.3 36.0 37.7 40.2 34.4 35.1 36.8 39.2 33.6 34.2 35.9 38.3 31.9 32.5 34.1 36.4 29.6 30.1 31.6 33.7
S/T 0.98 0.95 0.86 0.70 1.00 0.98 0.89 0.72 1.00 1.00 0.91 0.74 1.00 1.00 0.94 0.76 1.00 1.00 0.98 0.79 1.00 1.00 0.98 0.80
∆T 23 23 22 19 23 23 22 19 23 23 22 19 22 22 22 19 21 21 22 19 19 20 20 18

www.goodmanmfg.com
1406 kW 2.41 2.46 2.54 2.63 2.60 2.66 2.75 2.84 2.77 2.83 2.93 3.03 2.92 2.99 3.09 3.19 3.05 3.12 3.22 3.34 3.16 3.23 3.34 3.46
Amps 9.5 9.8 10.1 10.5 10.3 10.6 11.0 11.4 11.3 11.6 12.0 12.4 12.1 12.4 12.8 13.3 12.9 13.2 13.7 14.2 13.7 14.0 14.5 15.1
Hi PR 154 166 175 183 173 186 197 205 197 212 224 234 224 242 255 266 252 272 287 299 279 300 317 331
Lo PR 65 69 75 80 68 73 79 85 71 76 83 88 75 79 87 92 78 83 91 97 81 86 94 100
MBh 35.1 35.7 37.4 39.9 34.3 34.9 36.6 39.0 33.4 34.1 35.7 38.1 32.6 33.3 34.8 37.2 31.0 31.6 33.1 35.3 28.7 29.3 30.6 32.7
S/T 0.94 0.91 0.82 0.66 0.97 0.94 0.85 0.69 1.00 0.96 0.87 0.71 1.00 0.99 0.90 0.73 1.00 1.00 0.93 0.76 1.00 1.00 0.94 0.76
∆T 24 24 23 19 25 24 23 20 25 24 23 20 24 24 23 20 23 23 23 20 21 22 21 18
85 1250 kW 2.39 2.44 2.52 2.61 2.58 2.64 2.73 2.82 2.75 2.81 2.90 3.00 2.90 2.96 3.06 3.17 3.02 3.09 3.20 3.31 3.13 3.20 3.31 3.43
Amps 9.4 9.7 10.0 10.4 10.2 10.5 10.9 11.3 11.2 11.4 11.8 12.3 12.0 12.3 12.7 13.2 12.8 13.1 13.5 14.1 13.5 13.9 14.4 14.9
Hi PR 153 165 174 181 172 185 195 203 195 210 222 231 222 239 253 263 250 269 284 296 276 297 314 327
Lo PR 64 68 74 79 68 72 79 84 70 75 82 87 74 79 86 91 77 82 90 96 80 85 93 99
MBh 32.4 33.0 34.6 36.9 31.6 32.2 33.8 36.0 30.9 31.5 32.9 35.1 30.1 30.7 32.1 34.3 28.6 29.2 30.5 32.6 26.5 27.0 28.3 30.2
S/T 0.91 0.87 0.79 0.64 0.94 0.91 0.82 0.66 0.96 0.93 0.84 0.68 0.99 0.96 0.86 0.70 1.00 0.99 0.90 0.73 1.00 1.00 0.91 0.73
∆T 25 24 23 20 25 25 23 20 25 25 23 20 25 25 23 20 24 24 23 20 22 23 22 19
1094 kW 2.33 2.38 2.46 2.54 2.52 2.57 2.66 2.75 2.68 2.74 2.83 2.93 2.82 2.89 2.98 3.09 2.94 3.01 3.11 3.22 3.05 3.12 3.23 3.34
Amps 9.2 9.4 9.7 10.1 10.0 10.2 10.6 11.0 10.8 11.1 11.5 12.0 11.6 11.9 12.3 12.8 12.4 12.7 13.1 13.7 13.2 13.5 14.0 14.5
Hi PR 148 160 169 176 166 179 189 197 189 204 215 224 216 232 245 255 242 261 276 287 268 288 304 318
Lo PR 62 66 72 77 66 70 76 81 68 73 79 84 72 76 83 89 75 80 87 93 78 83 90 96
IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions kW = Total system power

17
High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)
Product Specifications
Outdoor Ambient Temperature

18
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
MBh 34.3 35.5 38.9 - 33.5 34.7 38.0 - 32.7 33.9 37.1 - 31.9 33.1 36.2 - 30.3 31.4 34.4 - 28.1 29.1 31.9 -
S/T 0.76 0.63 0.44 - 0.79 0.66 0.45 - 0.81 0.67 0.47 - 0.83 0.69 0.48 - 0.86 0.72 0.50 - 0.87 0.73 0.50 -
∆T 18 15 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 15 12 - 17 14 11 -
1350 kW 2.61 2.66 2.74 - 2.80 2.85 2.94 - 2.96 3.02 3.12 - 3.11 3.18 3.27 - 3.23 3.30 3.41 - 3.34 3.41 3.52 -
Amps 11.1 11.3 11.6 - 11.8 12.1 12.4 - 12.7 13.0 13.3 - 13.4 13.7 14.1 - 14.2 14.5 14.9 - 14.9 15.2 15.7 -
Hi PR 247 266 281 - 277 298 315 - 315 339 358 - 359 387 408 - 404 435 459 - 446 480 507 -
Product Specifications

Lo PR 110 117 128 - 116 124 135 - 121 129 140 - 127 135 148 - 133 142 155 - 138 146 160 -
MBh 33.3 34.5 37.8 - 32.5 33.7 36.9 - 31.7 32.9 36.1 - 31.0 32.1 35.2 - 29.4 30.5 33.4 - 27.3 28.3 31.0 -
S/T 0.72 0.60 0.42 - 0.75 0.63 0.43 - 0.77 0.64 0.44 - 0.79 0.66 0.46 - 0.82 0.69 0.48 - 0.83 0.69 0.48 -
∆T 18 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 17 15 11 -
70 1200 kW 2.59 2.64 2.72 - 2.78 2.83 2.92 - 2.94 3.00 3.09 - 3.09 3.15 3.25 - 3.21 3.28 3.38 - 3.32 3.39 3.49 -
Amps 11.0 11.2 11.5 - 11.8 12.0 12.3 - 12.6 12.9 13.2 - 13.3 13.6 14.0 - 14.1 14.4 14.8 - 14.8 15.1 15.6 -
Hi PR 245 263 278 - 275 295 312 - 312 336 355 - 356 383 404 - 400 431 455 - 442 476 502 -
Lo PR 109 116 127 - 115 123 134 - 120 127 139 - 126 134 146 - 132 140 153 - 136 145 158 -
MBh 30.7 31.9 34.9 - 30.0 31.1 34.1 - 29.3 30.4 33.3 - 28.6 29.6 32.5 - 27.2 28.2 30.8 - 25.2 26.1 28.6 -
S/T 0.70 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.79 0.66 0.46 - 0.80 0.67 0.46 -
∆T 19 16 12 - 19 16 12 - 19 16 12 - 19 17 13 - 19 16 12 - 18 15 12 -
1050 kW 2.53 2.58 2.66 - 2.71 2.77 2.85 - 2.87 2.93 3.02 - 3.01 3.08 3.17 - 3.13 3.20 3.30 - 3.24 3.30 3.41 -
Expanded Cooling Data — GPH1336H41*

Amps 10.8 11.0 11.3 - 11.5 11.7 12.0 - 12.3 12.6 12.9 - 13.0 13.3 13.7 - 13.7 14.0 14.4 - 14.4 14.8 15.2 -
Hi PR 237 255 270 - 266 287 303 - 303 326 344 - 345 371 392 - 388 418 441 - 429 461 487 -
Lo PR 106 113 123 - 112 119 130 - 116 124 135 - 122 130 142 - 128 136 148 - 132 141 154 -

MBh 34.9 35.9 38.9 41.7 34.1 35.1 38.0 40.7 33.3 34.2 37.1 39.8 32.4 33.4 36.2 38.8 30.8 31.7 34.4 36.9 28.6 29.4 31.8 34.2
S/T 0.86 0.77 0.58 0.38 0.89 0.80 0.60 0.39 0.92 0.82 0.62 0.40 0.94 0.85 0.64 0.41 0.98 0.88 0.66 0.43 0.99 0.88 0.67 0.43
∆T 20 19 15 11 21 19 16 11 21 19 16 11 21 19 16 11 21 19 16 11 19 18 15 10

www.goodmanmfg.com
1350 kW 2.63 2.68 2.76 2.84 2.82 2.88 2.96 3.06 2.99 3.05 3.14 3.24 3.13 3.20 3.30 3.41 3.26 3.33 3.44 3.55 3.37 3.44 3.55 3.67
Amps 11.2 11.4 11.7 12.1 11.9 12.2 12.5 12.9 12.8 13.1 13.4 13.9 13.6 13.8 14.2 14.7 14.3 14.6 15.0 15.5 15.0 15.4 15.8 16.4
Hi PR 250 269 284 296 280 301 318 332 319 343 362 378 363 391 412 430 408 439 464 484 451 485 513 535
Lo PR 111 118 129 138 118 125 137 145 122 130 142 151 128 137 149 159 134 143 156 166 139 148 162 172
MBh 33.9 34.9 37.7 40.5 33.1 34.1 36.9 39.6 32.3 33.2 36.0 38.6 31.5 32.4 35.1 37.7 29.9 30.8 33.3 35.8 27.7 28.5 30.9 33.2
S/T 0.82 0.73 0.56 0.36 0.85 0.76 0.58 0.37 0.87 0.78 0.59 0.38 0.90 0.81 0.61 0.39 0.94 0.84 0.63 0.41 0.94 0.84 0.64 0.41
∆T 21 20 16 11 22 20 16 11 22 20 16 11 22 20 16 11 21 20 16 11 20 18 15 10
75 1200 kW 2.61 2.66 2.74 2.82 2.80 2.85 2.94 3.03 2.96 3.02 3.12 3.22 3.11 3.18 3.27 3.38 3.23 3.30 3.41 3.52 3.34 3.41 3.52 3.64
Amps 11.1 11.3 11.6 12.0 11.8 12.1 12.4 12.8 12.7 13.0 13.3 13.8 13.4 13.7 14.1 14.6 14.2 14.5 14.9 15.4 14.9 15.2 15.7 16.2
Hi PR 247 266 281 293 277 298 315 329 315 339 358 374 359 387 408 426 404 435 459 479 447 481 507 529
Lo PR 110 117 128 136 116 124 135 144 121 129 140 150 127 135 148 157 133 142 155 165 138 147 160 170
MBh 31.3 32.2 34.8 37.4 30.5 31.4 34.0 36.5 29.8 30.7 33.2 35.6 29.1 29.9 32.4 34.8 27.6 28.4 30.8 33.0 25.6 26.3 28.5 30.6
S/T 0.79 0.71 0.54 0.34 0.82 0.73 0.56 0.36 0.84 0.75 0.57 0.37 0.87 0.78 0.59 0.38 0.90 0.81 0.61 0.39 0.91 0.81 0.62 0.40
∆T 22 20 16 11 22 20 17 11 22 20 17 11 22 20 17 12 22 20 16 11 20 19 15 11
1050 kW 2.55 2.60 2.68 2.76 2.73 2.79 2.87 2.96 2.89 2.95 3.04 3.14 3.04 3.10 3.20 3.30 3.16 3.22 3.33 3.43 3.26 3.33 3.44 3.55
Amps 10.9 11.1 11.4 11.7 11.6 11.8 12.1 12.5 12.4 12.7 13.0 13.4 13.1 13.4 13.8 14.2 13.9 14.1 14.6 15.0 14.6 14.9 15.3 15.8
Hi PR 240 258 272 284 269 290 306 319 306 329 348 363 349 375 396 413 392 422 446 465 433 466 492 513
Lo PR 107 114 124 132 113 120 131 140 117 125 136 145 123 131 143 152 129 137 150 160 134 142 155 165
IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions kW = Total system power

SS-GPH13H
High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)
Outdoor Ambient Temperature
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71

SS-GPH13H
MBh 35.5 36.3 38.8 41.4 34.7 35.4 37.9 40.5 33.8 34.6 37.0 39.5 33.0 33.7 36.1 38.5 31.4 32.1 34.2 36.6 29.1 29.7 31.7 33.9
S/T 0.94 0.89 0.72 0.54 1.00 0.92 0.75 0.56 1.00 0.94 0.77 0.57 1.00 1.00 0.79 0.59 1.00 1.00 0.82 0.61 1.00 1.00 0.83 0.62
∆T 23 22 19 15 24 22 19 15 23 22 19 15 22 23 19 16 21 22 19 15 20 20 18 14
1350 kW 2.65 2.70 2.78 2.87 2.84 2.90 2.99 3.08 3.01 3.07 3.17 3.27 3.16 3.23 3.33 3.43 3.29 3.36 3.46 3.57 3.40 3.47 3.58 3.70
Amps 11.3 11.5 11.8 12.2 12.0 12.3 12.6 13.0 12.9 13.2 13.5 14.0 13.7 14.0 14.4 14.8 14.4 14.7 15.2 15.7 15.2 15.5 16.0 16.5
Hi PR 252 271 287 299 283 305 322 335 322 346 366 381 367 394 417 434 412 444 469 489 456 490 518 540
Lo PR 112 120 131 139 119 126 138 147 123 131 143 153 130 138 151 160 136 145 158 168 141 149 163 174
MBh 34.5 35.2 37.6 40.2 33.7 34.4 36.8 39.3 32.9 33.6 35.9 38.4 32.1 32.8 35.0 37.4 30.5 31.1 33.3 35.5 28.2 28.8 30.8 32.9
S/T 0.90 0.84 0.69 0.51 0.93 0.88 0.71 0.53 0.96 0.90 0.73 0.55 0.99 0.93 0.75 0.56 1.00 0.96 0.78 0.59 1.00 0.97 0.79 0.59
∆T 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 23 23 20 16 22 21 19 15
80 1200 kW 2.63 2.68 2.76 2.84 2.82 2.88 2.96 3.06 2.99 3.05 3.14 3.24 3.13 3.20 3.30 3.41 3.26 3.33 3.44 3.55 3.37 3.44 3.55 3.67
Amps 11.2 11.4 11.7 12.1 11.9 12.2 12.5 12.9 12.8 13.1 13.4 13.9 13.6 13.8 14.2 14.7 14.3 14.6 15.0 15.5 15.0 15.4 15.8 16.4
Hi PR 250 269 284 296 280 301 318 332 319 343 362 378 363 391 412 430 408 439 464 484 451 485 513 535
Lo PR 111 118 129 138 118 125 137 145 122 130 142 151 128 137 149 159 134 143 156 166 139 148 162 172
MBh 31.8 32.5 34.7 37.1 31.1 31.7 33.9 36.3 30.3 31.0 33.1 35.4 29.6 30.2 32.3 34.5 28.1 28.7 30.7 32.8 26.0 26.6 28.4 30.4
S/T 0.87 0.81 0.66 0.50 0.90 0.84 0.69 0.51 0.92 0.87 0.70 0.53 0.95 0.89 0.73 0.54 0.99 0.93 0.75 0.56 1.00 0.94 0.76 0.57
∆T 24 23 20 16 24 23 20 16 25 23 20 16 25 24 21 16 24 23 20 16 23 22 19 15
1050 kW 2.57 2.62 2.70 2.78 2.75 2.81 2.89 2.98 2.92 2.98 3.07 3.16 3.06 3.12 3.22 3.32 3.18 3.25 3.35 3.46 3.29 3.36 3.46 3.58
Amps 10.9 11.2 11.5 11.8 11.7 11.9 12.2 12.6 12.5 12.8 13.1 13.5 13.2 13.5 13.9 14.4 14.0 14.3 14.7 15.2 14.7 15.0 15.4 16.0
Hi PR 242 261 275 287 272 292 309 322 309 333 351 366 352 379 400 417 396 426 450 469 438 471 497 519
Lo PR 108 115 125 133 114 121 132 141 119 126 138 147 124 132 145 154 130 139 152 161 135 144 157 167
Expanded Cooling Data — GPH1336H41* (cont.)

MBh 36.1 36.8 38.6 41.1 35.3 36.0 37.7 40.2 34.4 35.1 36.8 39.2 33.6 34.2 35.9 38.3 31.9 32.5 34.1 36.4 29.6 30.1 31.6 33.7
S/T 0.99 0.96 0.86 0.70 1.00 0.99 0.89 0.73 1.00 1.00 0.92 0.74 1.00 1.00 0.95 0.77 1.00 1.00 0.98 0.80 1.00 1.00 0.99 0.80
∆T 24 24 23 20 24 24 23 20 23 24 23 20 23 23 23 20 22 22 23 20 20 21 21 18

www.goodmanmfg.com
1350 kW 2.67 2.72 2.80 2.89 2.86 2.92 3.01 3.10 3.03 3.10 3.19 3.29 3.18 3.25 3.35 3.46 3.31 3.38 3.49 3.60 3.42 3.50 3.61 3.73
Amps 11.4 11.6 11.9 12.3 12.1 12.4 12.7 13.1 13.0 13.3 13.7 14.1 13.8 14.1 14.5 14.9 14.5 14.8 15.3 15.8 15.3 15.6 16.1 16.6
Hi PR 255 274 289 302 286 308 325 339 325 350 369 385 370 398 421 439 416 448 473 494 460 495 523 545
Lo PR 114 121 132 140 120 128 139 148 125 133 145 154 131 139 152 162 137 146 159 170 142 151 165 176
MBh 35.1 35.7 37.4 39.9 34.3 34.9 36.6 39.0 33.4 34.1 35.7 38.1 32.6 33.3 34.8 37.2 31.0 31.6 33.1 35.3 28.7 29.3 30.6 32.7
S/T 0.94 0.91 0.82 0.67 0.98 0.94 0.85 0.69 1.00 0.97 0.87 0.71 1.00 1.00 0.90 0.73 1.00 1.00 0.94 0.76 1.00 1.00 0.94 0.77
∆T 25 25 24 20 26 25 24 21 26 25 24 21 25 25 24 21 24 24 24 21 22 22 22 19
85 1200 kW 2.65 2.70 2.78 2.87 2.84 2.90 2.99 3.08 3.01 3.07 3.17 3.27 3.16 3.23 3.33 3.43 3.29 3.36 3.46 3.57 3.40 3.47 3.58 3.70
Amps 11.3 11.5 11.8 12.2 12.0 12.3 12.6 13.0 12.9 13.2 13.5 14.0 13.7 14.0 14.4 14.8 14.4 14.7 15.2 15.7 15.2 15.5 16.0 16.5
Hi PR 252 271 287 299 283 305 322 335 322 346 366 381 367 394 417 434 412 444 469 489 456 490 518 540
Lo PR 112 120 131 139 119 126 138 147 123 131 143 153 130 138 151 160 136 145 158 168 141 149 163 174
MBh 32.4 33.0 34.6 36.9 31.6 32.2 33.8 36.0 30.9 31.5 32.9 35.1 30.1 30.7 32.1 34.3 28.6 29.2 30.5 32.6 26.5 27.0 28.3 30.2
S/T 0.91 0.88 0.79 0.64 0.94 0.91 0.82 0.67 0.97 0.93 0.84 0.68 1.00 0.96 0.87 0.71 1.00 1.00 0.90 0.73 1.00 1.00 0.91 0.74
∆T 26 25 24 21 26 26 24 21 26 26 24 21 26 26 24 21 25 26 24 21 23 24 23 20
1050 kW 2.59 2.64 2.72 2.80 2.78 2.83 2.92 3.01 2.94 3.00 3.09 3.19 3.08 3.15 3.25 3.35 3.21 3.28 3.38 3.49 3.31 3.39 3.49 3.61
Amps 11.0 11.2 11.5 11.9 11.8 12.0 12.3 12.7 12.6 12.9 13.2 13.7 13.3 13.6 14.0 14.5 14.1 14.4 14.8 15.3 14.8 15.1 15.6 16.1
Hi PR 245 263 278 290 274 295 312 325 312 336 355 370 356 383 404 421 400 430 455 474 442 476 502 524
Lo PR 109 116 127 135 115 123 134 142 120 127 139 148 126 134 146 156 132 140 153 163 136 145 158 169
IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions kW = Total system power

19
Product Specifications

High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)
Outdoor Ambient Temperature

20
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
MBh 40.2 41.6 45.6 - 39.2 40.7 44.6 - 38.3 39.7 43.5 - 37.4 38.74 42.4 - 35.5 36.8 40.3 - 32.9 34.1 37.3 -
S/T 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.86 0.72 0.50 - 0.86 0.72 0.50 -
∆T 17 15 11 - 17 15 11 - 17 15 11 - 17 15 11 - 17 15 11 - 16 14 11 -
1631 kW 2.44 2.50 2.58 - 2.64 2.69 2.78 - 2.81 2.87 2.97 - 2.96 3.03 3.13 - 3.09 3.16 3.27 - 3.20 3.27 3.38 -
Amps 9.3 9.5 9.8 - 10.0 10.3 10.7 - 11.0 11.2 11.6 - 11.7 12.0 12.4 - 12.5 12.8 13.3 - 13.3 13.6 14.1 -
Product Specifications

Hi PR 144 155 163 - 161 174 183 - 184 198 209 - 209 225 238 - 235 253 267 - 260 280 295 -
Lo PR 64 68 74 - 67 71 78 - 70 74 81 - 73 78 85 - 77 82 89 - 79 85 92 -
MBh 39.0 40.4 44.3 - 38.1 39.5 43.3 - 37.2 38.5 42.2 - 36.3 37.6 41.2 - 34.5 35.7 39.1 - 31.9 33.1 36.3 -
S/T 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.79 0.66 0.46 - 0.82 0.68 0.47 - 0.82 0.69 0.48 -
∆T 18 15 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 15 12 - 17 14 11 -
70 1450 kW 2.42 2.47 2.56 - 2.61 2.67 2.76 - 2.78 2.85 2.94 - 2.93 3.00 3.10 - 3.06 3.13 3.24 - 3.17 3.24 3.35 -
Amps 9.2 9.4 9.7 - 10.0 10.2 10.6 - 10.9 11.1 11.5 - 11.6 11.9 12.3 - 12.4 12.7 13.2 - 13.2 13.5 14.0 -
Hi PR 142 153 162 - 160 172 182 - 182 196 207 - 207 223 235 - 233 251 265 - 257 277 292 -
Lo PR 63 67 73 - 66 71 77 - 69 73 80 - 73 77 84 - 76 81 88 - 79 84 91 -
MBh 36.0 37.3 40.9 - 35.2 36.4 39.9 - 34.3 35.6 39.0 - 33.5 34.7 38.0 - 31.8 33.0 36.1 - 29.5 30.5 33.5 -
S/T 0.69 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.61 0.43 - 0.76 0.63 0.44 - 0.79 0.66 0.46 - 0.80 0.66 0.46 -
∆T 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -
1269 kW 2.36 2.41 2.49 - 2.55 2.60 2.69 - 2.71 2.77 2.87 - 2.86 2.92 3.02 - 2.98 3.05 3.15 - 3.09 3.16 3.27 -
Expanded Cooling Data — GPH1342H21*

Amps 8.9 9.1 9.5 - 9.7 9.9 10.3 - 10.5 10.8 11.2 - 11.3 11.6 12.0 - 12.0 12.3 12.8 - 12.8 13.1 13.6 -
Hi PR 138 149 157 - 155 167 176 - 176 190 200 - 201 216 228 - 226 243 257 - 250 269 284 -
Lo PR 61 65 71 - 64 69 75 - 67 71 78 - 70 75 82 - 74 78 86 - 76 81 89 -

MBh 40.9 42.1 45.5 48.9 39.9 41.1 44.5 47.7 39.0 40.1 43.4 46.6 38.0 39.1 42.4 45.5 36.1 37.2 40.2 43.2 33.4 34.4 37.3 40.0
S/T 0.86 0.77 0.58 0.37 0.89 0.79 0.60 0.39 0.91 0.81 0.62 0.40 0.94 0.84 0.64 0.41 0.97 0.87 0.66 0.42 0.98 0.88 0.67 0.43
∆T 20 18 15 10 20 18 15 10 20 18 15 10 20 19 15 10 20 18 15 10 19 17 14 10

www.goodmanmfg.com
1631 kW 2.46 2.52 2.60 2.68 2.66 2.72 2.81 2.90 2.83 2.90 2.99 3.09 2.98 3.05 3.16 3.26 3.11 3.19 3.29 3.41 3.23 3.30 3.41 3.53
Amps 9.4 9.6 9.9 10.3 10.1 10.4 10.8 11.2 11.1 11.3 11.7 12.2 11.8 12.1 12.6 13.1 12.6 13.0 13.4 13.9 13.4 13.8 14.2 14.8
Hi PR 145 156 165 172 163 175 185 193 185 200 211 220 211 227 240 250 238 256 270 282 262 282 298 311
Lo PR 64 68 75 79 68 72 79 84 70 75 82 87 74 79 86 92 78 83 90 96 80 85 93 99
MBh 39.7 40.8 44.2 47.4 38.7 39.9 43.2 46.3 37.8 38.9 42.2 45.2 36.9 38.0 41.1 44.1 35.1 36.1 39.1 41.9 32.5 33.4 36.2 38.8
S/T 0.82 0.73 0.55 0.36 0.85 0.76 0.57 0.37 0.87 0.78 0.59 0.38 0.90 0.80 0.61 0.39 0.93 0.83 0.63 0.40 0.94 0.84 0.63 0.41
∆T 21 19 15 11 21 19 16 11 21 19 16 11 21 19 16 11 21 19 16 11 19 18 15 10
75 1450 kW 2.44 2.50 2.58 2.66 2.64 2.69 2.78 2.88 2.81 2.87 2.97 3.07 2.96 3.03 3.13 3.24 3.09 3.16 3.27 3.38 3.20 3.27 3.38 3.50
Amps 9.3 9.5 9.8 10.2 10.1 10.3 10.7 11.1 11.0 11.2 11.6 12.1 11.7 12.0 12.5 12.9 12.5 12.8 13.3 13.8 13.3 13.6 14.1 14.7
Hi PR 144 155 163 170 161 174 183 191 184 198 209 218 209 225 238 248 235 253 267 279 260 280 295 308
Lo PR 64 68 74 79 67 71 78 83 70 74 81 86 73 78 85 91 77 82 89 95 79 85 92 98
MBh 36.6 37.7 40.8 43.8 35.8 36.8 39.9 42.8 34.9 35.9 38.9 41.8 34.1 35.1 38.0 40.7 32.4 33.3 36.1 38.7 30.0 30.9 33.4 35.8
S/T 0.79 0.70 0.53 0.34 0.82 0.73 0.55 0.36 0.84 0.75 0.57 0.36 0.86 0.77 0.58 0.38 0.90 0.80 0.61 0.39 0.90 0.81 0.61 0.39
∆T 21 19 16 11 21 19 16 11 21 19 16 11 21 20 16 11 21 19 16 11 20 18 15 10
1269 kW 2.38 2.43 2.51 2.60 2.57 2.63 2.71 2.80 2.74 2.80 2.89 2.99 2.88 2.95 3.05 3.15 3.01 3.08 3.18 3.29 3.12 3.19 3.30 3.41
Amps 9.0 9.2 9.5 9.9 9.8 10.0 10.4 10.8 10.6 10.9 11.3 11.7 11.4 11.7 12.1 12.6 12.2 12.5 12.9 13.4 12.9 13.2 13.7 14.2
Hi PR 140 150 159 165 157 168 178 186 178 192 202 211 203 218 230 240 228 246 259 270 252 271 286 299
Lo PR 62 66 72 76 65 69 76 81 68 72 79 84 71 76 83 88 75 79 87 92 77 82 90 95
IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions kW = Total system power

SS-GPH13H
High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)
Outdoor Ambient Temperature
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71

SS-GPH13H
MBh 41.6 42.5 45.4 48.5 40.6 41.5 44.3 47.4 39.6 40.5 43.3 46.3 38.7 39.5 42.2 45.1 36.7 37.6 40.1 42.9 34.0 34.8 37.2 39.7
S/T 0.94 0.88 0.72 0.54 1.00 0.91 0.74 0.56 1.00 0.94 0.76 0.57 1.00 0.97 0.79 0.59 1.00 1.00 0.82 0.61 1.00 1.00 0.82 0.62
∆T 22 21 18 15 23 21 19 15 22 21 19 15 22 22 19 15 21 21 18 15 19 20 17 14
1631 kW 2.48 2.54 2.62 2.71 2.68 2.74 2.83 2.93 2.86 2.92 3.02 3.12 3.01 3.08 3.18 3.29 3.14 3.21 3.32 3.44 3.25 3.33 3.44 3.56
Amps 9.4 9.7 10.0 10.4 10.2 10.5 10.9 11.3 11.2 11.4 11.8 12.3 12.0 12.3 12.7 13.2 12.8 13.1 13.5 14.1 13.5 13.9 14.4 14.9
Hi PR 147 158 167 174 165 177 187 195 187 202 213 222 213 230 242 253 240 258 273 284 265 285 301 314
Lo PR 65 69 75 80 69 73 80 85 71 76 83 88 75 80 87 93 78 83 91 97 81 86 94 100
MBh 40.4 41.3 44.1 47.1 39.4 40.3 43.1 46.0 38.5 39.3 42.0 44.9 37.6 38.4 41.0 43.8 35.7 36.5 39.0 41.6 33.0 33.8 36.1 38.6
S/T 0.90 0.84 0.68 0.51 0.93 0.87 0.71 0.53 0.95 0.89 0.73 0.54 0.98 0.92 0.75 0.56 1.00 0.96 0.78 0.58 1.00 0.96 0.78 0.59
∆T 23 22 19 15 23 22 19 15 23 22 19 15 23 22 19 16 23 22 19 15 21 21 18 14
80 1450 kW 2.46 2.52 2.60 2.68 2.66 2.72 2.81 2.90 2.83 2.90 2.99 3.10 2.98 3.05 3.16 3.26 3.11 3.19 3.29 3.41 3.23 3.30 3.41 3.53
Amps 9.4 9.6 9.9 10.3 10.1 10.4 10.8 11.2 11.1 11.3 11.7 12.2 11.9 12.2 12.6 13.1 12.6 13.0 13.4 13.9 13.4 13.8 14.2 14.8
Hi PR 145 156 165 172 163 175 185 193 185 200 211 220 211 227 240 250 238 256 270 282 263 283 298 311
Lo PR 64 68 75 79 68 72 79 84 70 75 82 87 74 79 86 92 78 83 90 96 80 85 93 99
MBh 37.3 38.1 40.7 43.5 36.4 37.2 39.7 42.5 35.5 36.3 38.8 41.5 34.7 35.4 37.8 40.5 32.9 33.6 36.0 38.4 30.5 31.2 33.3 35.6
S/T 0.86 0.81 0.66 0.49 0.90 0.84 0.68 0.51 0.92 0.86 0.70 0.52 0.95 0.89 0.72 0.54 0.98 0.92 0.75 0.56 0.99 0.93 0.76 0.57
∆T 23 22 19 16 24 23 20 16 24 23 20 16 24 23 20 16 23 22 20 16 22 21 18 15
1269 kW 2.40 2.45 2.53 2.62 2.59 2.65 2.74 2.83 2.76 2.82 2.92 3.02 2.91 2.97 3.07 3.18 3.03 3.10 3.21 3.32 3.14 3.22 3.33 3.44
Amps 9.1 9.3 9.6 10.0 9.9 10.1 10.5 10.9 10.7 11.0 11.4 11.8 11.5 11.8 12.2 12.7 12.3 12.6 13.0 13.5 13.0 13.4 13.8 14.4
Hi PR 141 152 160 167 158 170 180 187 180 194 204 213 205 220 233 243 230 248 262 273 255 274 289 302
Lo PR 62 66 72 77 66 70 76 81 68 73 79 85 72 76 83 89 75 80 87 93 78 83 90 96
Expanded Cooling Data — GPH1342H21* (cont.)

MBh 42.3 43.1 45.2 48.2 41.3 42.1 44.1 47.1 40.3 41.1 43.1 45.9 39.4 40.1 42.0 44.8 37.4 38.1 39.9 42.6 34.6 35.3 37.0 39.4
S/T 0.98 0.95 0.86 0.70 1.00 0.98 0.89 0.72 1.00 1.00 0.91 0.74 1.00 1.00 0.94 0.76 1.00 1.00 0.98 0.79 1.00 1.00 0.98 0.80
∆T 23 23 22 19 23 23 22 19 23 23 22 19 22 23 22 19 21 21 22 19 20 20 21 18

www.goodmanmfg.com
1631 kW 2.50 2.56 2.64 2.73 2.70 2.76 2.86 2.95 2.88 2.95 3.04 3.15 3.04 3.11 3.21 3.32 3.17 3.24 3.35 3.47 3.28 3.36 3.47 3.60
Amps 9.5 9.8 10.1 10.5 10.3 10.6 11.0 11.4 11.3 11.6 12.0 12.4 12.1 12.4 12.8 13.3 12.9 13.2 13.7 14.2 13.7 14.0 14.5 15.1
Hi PR 148 160 168 176 166 179 189 197 189 204 215 224 215 232 245 255 242 261 275 287 268 288 304 317
Lo PR 65 70 76 81 69 74 80 86 72 77 84 89 76 80 88 93 79 84 92 98 82 87 95 101
MBh 41.1 41.9 43.9 46.8 40.1 40.9 42.8 45.7 39.2 39.9 41.8 44.6 38.2 39.0 40.8 43.5 36.3 37.0 38.8 41.3 33.6 34.3 35.9 38.3
S/T 0.94 0.91 0.82 0.66 0.97 0.94 0.85 0.69 1.00 0.96 0.87 0.71 1.00 0.99 0.90 0.73 1.00 1.00 0.93 0.76 1.00 1.00 0.94 0.76
∆T 24 24 23 20 25 24 23 20 25 24 23 20 24 25 23 20 23 23 23 20 21 22 21 18
85 1450 kW 2.48 2.54 2.62 2.71 2.68 2.74 2.83 2.93 2.86 2.92 3.02 3.12 3.01 3.08 3.18 3.29 3.14 3.21 3.32 3.44 3.25 3.33 3.44 3.56
Amps 9.4 9.7 10.0 10.4 10.2 10.5 10.9 11.3 11.2 11.4 11.8 12.3 12.0 12.3 12.7 13.2 12.8 13.1 13.5 14.1 13.5 13.9 14.4 14.9
Hi PR 147 158 167 174 165 177 187 195 187 202 213 222 213 230 242 253 240 258 273 284 265 285 301 314
Lo PR 65 69 75 80 69 73 80 85 71 76 83 88 75 80 87 93 78 83 91 97 81 86 94 100
MBh 37.9 38.6 40.5 43.2 37.0 37.7 39.5 42.2 36.2 36.9 38.6 41.2 35.3 36.0 37.7 40.2 33.5 34.2 35.8 38.2 31.0 31.6 33.1 35.4
S/T 0.91 0.87 0.79 0.64 0.94 0.91 0.82 0.66 0.96 0.93 0.84 0.68 0.99 0.96 0.86 0.70 1.00 0.99 0.90 0.73 1.00 1.00 0.91 0.73
∆T 25 24 23 20 25 25 23 20 25 25 23 20 25 25 24 20 24 25 23 20 22 23 22 19
1269 kW 2.42 2.47 2.55 2.64 2.61 2.67 2.76 2.85 2.78 2.85 2.94 3.04 2.93 3.00 3.10 3.21 3.06 3.13 3.24 3.35 3.17 3.24 3.35 3.47
Amps 9.2 9.4 9.7 10.1 10.0 10.2 10.6 11.0 10.8 11.1 11.5 12.0 11.6 11.9 12.3 12.8 12.4 12.7 13.1 13.7 13.2 13.5 14.0 14.5
Hi PR 142 153 162 169 160 172 182 189 182 196 206 215 207 223 235 245 233 250 265 276 257 277 292 305
Lo PR 63 67 73 78 66 71 77 82 69 73 80 85 73 77 84 90 76 81 88 94 79 84 91 97
IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions kW = Total system power

21
High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)
Product Specifications
Outdoor Ambient Temperature

22
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
MBh 39.7 41.1 45.1 - 38.8 40.2 44.0 - 37.8 39.2 43.0 - 36.9 38.3 41.9 - 35.1 36.4 39.8 - 32.5 33.7 36.9 -
S/T 0.76 0.63 0.44 - 0.79 0.66 0.46 - 0.81 0.67 0.47 - 0.83 0.70 0.48 - 0.87 0.72 0.50 - 0.87 0.73 0.50 -
∆T 17 15 11 - 18 15 12 - 18 15 12 - 18 15 12 - 18 15 12 - 16 14 11 -
1585 kW 2.82 2.88 2.96 - 3.02 3.08 3.17 - 3.20 3.26 3.36 - 3.35 3.42 3.52 - 3.48 3.55 3.66 - 3.59 3.67 3.78 -
Amps 12.4 12.6 13.0 - 13.2 13.5 13.8 - 14.2 14.4 14.8 - 15.0 15.3 15.7 - 15.8 16.1 16.6 - 16.6 16.9 17.4 -
Hi PR 235 253 267 - 264 284 300 - 300 323 341 - 342 368 388 - 384 414 437 - 425 457 483 -
Product Specifications

Lo PR 113 120 132 - 120 127 139 - 124 132 144 - 131 139 152 - 137 146 159 - 142 151 164 -
MBh 38.5 39.9 43.8 - 37.6 39.0 42.7 - 36.7 38.1 41.7 - 35.8 37.1 40.7 - 34.1 35.3 38.7 - 31.5 32.7 35.8 -
S/T 0.72 0.61 0.42 - 0.75 0.63 0.43 - 0.77 0.64 0.45 - 0.79 0.66 0.46 - 0.83 0.69 0.48 - 0.83 0.69 0.48 -
∆T 18 16 12 - 18 16 12 - 18 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -
70 1410 kW 2.80 2.86 2.94 - 3.00 3.06 3.15 - 3.17 3.24 3.33 - 3.32 3.39 3.49 - 3.45 3.52 3.63 - 3.57 3.64 3.75 -
Amps 12.3 12.5 12.9 - 13.1 13.4 13.7 - 14.0 14.3 14.7 - 14.9 15.2 15.6 - 15.7 16.0 16.4 - 16.5 16.8 17.3 -
Hi PR 233 251 265 - 261 281 297 - 297 320 338 - 338 364 385 - 381 410 433 - 421 453 478 -
Lo PR 112 119 130 - 118 126 138 - 123 131 143 - 129 138 150 - 136 144 157 - 140 149 163 -
MBh 35.6 36.9 40.4 - 34.7 36.0 39.4 - 33.9 35.1 38.5 - 33.1 34.3 37.6 - 31.4 32.6 35.7 - 29.1 30.2 33.1 -
S/T 0.70 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.80 0.66 0.46 - 0.80 0.67 0.46 -
∆T 18 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 17 15 11 -
1236 kW 2.74 2.80 2.88 - 2.93 2.99 3.08 - 3.10 3.16 3.26 - 3.25 3.31 3.41 - 3.37 3.44 3.55 - 3.48 3.55 3.66 -
Expanded Cooling Data — GPH1342H41*

Amps 12.0 12.3 12.6 - 12.8 13.1 13.4 - 13.7 14.0 14.4 - 14.5 14.8 15.2 - 15.3 15.6 16.1 - 16.1 16.4 16.9 -
Hi PR 226 243 257 - 253 273 288 - 288 310 327 - 328 353 373 - 369 397 420 - 408 439 464 -
Lo PR 109 116 126 - 115 122 133 - 119 127 139 - 125 133 146 - 131 140 153 - 136 145 158 -

MBh 40.4 41.6 45.0 48.3 39.4 40.6 43.9 47.2 38.5 39.6 42.9 46.0 37.5 38.7 41.8 44.9 35.7 36.7 39.7 42.7 33.0 34.0 36.8 39.5
S/T 0.86 0.77 0.58 0.38 0.90 0.80 0.61 0.39 0.92 0.82 0.62 0.40 0.95 0.85 0.64 0.41 0.98 0.88 0.67 0.43 0.99 0.89 0.67 0.43
∆T 20 19 15 11 20 19 15 11 20 19 15 11 21 19 16 11 20 19 15 11 19 18 14 10

www.goodmanmfg.com
1585 kW 2.85 2.90 2.98 3.07 3.04 3.10 3.20 3.29 3.22 3.29 3.38 3.49 3.38 3.44 3.55 3.66 3.51 3.58 3.69 3.81 3.62 3.70 3.81 3.93
Amps 12.5 12.7 13.1 13.5 13.3 13.6 13.9 14.4 14.3 14.6 15.0 15.4 15.1 15.4 15.8 16.4 15.9 16.2 16.7 17.3 16.7 17.1 17.6 18.2
Hi PR 238 256 270 282 267 287 303 316 303 326 344 359 345 372 392 409 388 418 441 460 429 462 488 509
Lo PR 114 122 133 141 121 129 140 149 126 134 146 155 132 140 153 163 138 147 161 171 143 152 166 177
MBh 39.2 40.3 43.7 46.9 38.3 39.4 42.7 45.8 37.4 38.5 41.6 44.7 36.5 37.5 40.6 43.6 34.6 35.7 38.6 41.4 32.1 33.0 35.7 38.4
S/T 0.82 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.88 0.78 0.59 0.38 0.90 0.81 0.61 0.39 0.94 0.84 0.63 0.41 0.95 0.85 0.64 0.41
∆T 21 19 16 11 21 20 16 11 21 20 16 11 21 20 16 11 21 20 16 11 20 18 15 10
75 1410 kW 2.82 2.88 2.96 3.05 3.02 3.08 3.17 3.27 3.20 3.26 3.36 3.46 3.35 3.42 3.52 3.63 3.48 3.55 3.66 3.78 3.59 3.67 3.78 3.90
Amps 12.4 12.6 13.0 13.4 13.2 13.5 13.8 14.3 14.2 14.4 14.8 15.3 15.0 15.3 15.7 16.2 15.8 16.1 16.6 17.1 16.6 16.9 17.4 18.0
Hi PR 235 253 267 279 264 284 300 313 300 323 341 356 342 368 388 405 385 414 437 456 425 457 483 504
Lo PR 113 120 132 140 120 127 139 148 124 132 144 154 131 139 152 162 137 146 159 169 142 151 164 175
MBh 36.2 37.2 40.3 43.3 35.3 36.4 39.4 42.3 34.5 35.5 38.4 41.2 33.6 34.6 37.5 40.2 32.0 32.9 35.6 38.2 29.6 30.5 33.0 35.4
S/T 0.79 0.71 0.54 0.35 0.82 0.74 0.56 0.36 0.84 0.75 0.57 0.37 0.87 0.78 0.59 0.38 0.90 0.81 0.61 0.39 0.91 0.82 0.62 0.40
∆T 21 20 16 11 22 20 16 11 22 20 16 11 22 20 16 11 22 20 16 11 20 18 15 10
1236 kW 2.76 2.82 2.90 2.98 2.96 3.01 3.10 3.19 3.12 3.19 3.28 3.38 3.27 3.34 3.44 3.55 3.40 3.47 3.58 3.69 3.51 3.58 3.69 3.81
Amps 12.1 12.4 12.7 13.1 12.9 13.2 13.5 13.9 13.8 14.1 14.5 15.0 14.6 14.9 15.3 15.8 15.4 15.7 16.2 16.7 16.2 16.5 17.0 17.6
Hi PR 228 245 259 270 256 275 291 303 291 313 331 345 332 357 377 393 373 401 424 442 412 444 468 488
Lo PR 110 117 128 136 116 123 135 144 121 128 140 149 127 135 147 157 133 141 154 164 137 146 160 170
IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions kW = Total system power
High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)

SS-GPH13H
Outdoor Ambient Temperature
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71

SS-GPH13H
MBh 41.1 42.0 44.8 47.9 40.1 41.0 43.8 46.8 39.2 40.0 42.8 45.7 38.2 39.0 41.7 44.6 36.3 37.1 39.6 42.4 33.6 34.4 36.7 39.2
S/T 0.95 0.89 0.72 0.54 1.00 0.92 0.75 0.56 1.00 0.94 0.77 0.57 1.00 1.00 0.79 0.59 1.00 1.00 0.82 0.62 1.00 1.00 0.83 0.62
∆T 23 22 19 15 23 22 19 15 23 22 19 15 22 23 19 15 21 22 19 15 20 20 18 14
1585 kW 2.87 2.92 3.01 3.09 3.07 3.13 3.22 3.32 3.24 3.31 3.41 3.52 3.40 3.47 3.58 3.69 3.54 3.61 3.72 3.84 3.65 3.73 3.84 3.96
Amps 12.6 12.8 13.2 13.6 13.4 13.7 14.1 14.5 14.4 14.7 15.1 15.6 15.2 15.5 16.0 16.5 16.0 16.4 16.8 17.4 16.9 17.2 17.7 18.3
Hi PR 240 258 273 284 269 290 306 319 306 329 348 363 349 375 396 413 392 422 446 465 433 466 493 514
Lo PR 116 123 134 143 122 130 142 151 127 135 147 157 133 142 155 165 140 149 162 173 144 154 168 179
MBh 39.9 40.8 43.5 46.5 39.0 39.8 42.5 45.5 38.0 38.9 41.5 44.4 37.1 37.9 40.5 43.3 35.2 36.0 38.5 41.1 32.6 33.4 35.6 38.1
S/T 0.90 0.85 0.69 0.52 0.94 0.88 0.71 0.53 0.96 0.90 0.73 0.55 0.99 0.93 0.76 0.57 1.00 0.96 0.79 0.59 1.00 0.97 0.79 0.59
∆T 23 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 23 23 20 16 21 21 18 15
80 1410 kW 2.85 2.90 2.98 3.07 3.04 3.10 3.20 3.29 3.22 3.29 3.38 3.49 3.38 3.45 3.55 3.66 3.51 3.58 3.69 3.81 3.62 3.70 3.81 3.93
Amps 12.5 12.7 13.1 13.5 13.3 13.6 14.0 14.4 14.3 14.6 15.0 15.4 15.1 15.4 15.8 16.4 15.9 16.2 16.7 17.3 16.7 17.1 17.6 18.2
Hi PR 238 256 270 282 267 287 303 316 303 326 344 359 345 372 392 409 388 418 441 460 429 462 488 509
Lo PR 114 122 133 142 121 129 140 150 126 134 146 155 132 140 153 163 138 147 161 171 143 152 166 177
MBh 36.8 37.6 40.2 43.0 36.0 36.7 39.3 42.0 35.1 35.9 38.3 41.0 34.2 35.0 37.4 40.0 32.5 33.2 35.5 38.0 30.1 30.8 32.9 35.2
S/T 0.87 0.82 0.66 0.50 0.90 0.85 0.69 0.52 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 0.99 0.93 0.76 0.57 1.00 0.94 0.76 0.57
∆T 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 22 21 19 15
1236 kW 2.78 2.84 2.92 3.00 2.98 3.04 3.12 3.22 3.15 3.21 3.31 3.41 3.30 3.37 3.47 3.57 3.43 3.50 3.60 3.72 3.54 3.61 3.72 3.84
Amps 12.2 12.5 12.8 13.2 13.0 13.3 13.6 14.1 13.9 14.2 14.6 15.1 14.7 15.0 15.5 16.0 15.5 15.9 16.3 16.8 16.3 16.7 17.2 17.7
Hi PR 230 248 262 273 259 278 294 306 294 316 334 349 335 360 381 397 377 405 428 447 416 448 473 493
Lo PR 111 118 129 137 117 125 136 145 122 130 142 151 128 136 149 158 134 143 156 166 139 148 161 172
Expanded Cooling Data — GPH1342H41* (cont.)

MBh 41.8 42.6 44.6 47.6 40.8 41.6 43.6 46.5 39.9 40.6 42.5 45.4 38.9 39.6 41.5 44.3 36.9 37.6 39.4 42.1 34.2 34.9 36.5 39.0
S/T 0.99 0.96 0.86 0.70 1.00 0.99 0.90 0.73 1.00 1.00 0.92 0.75 1.00 1.00 0.95 0.77 1.00 1.00 0.98 0.80 1.00 1.00 0.99 0.81
∆T 24 24 22 19 24 24 23 20 23 24 23 20 23 23 23 20 21 22 23 19 20 20 21 18

www.goodmanmfg.com
1585 kW 2.89 2.94 3.03 3.12 3.09 3.15 3.24 3.34 3.27 3.34 3.44 3.54 3.43 3.50 3.61 3.72 3.56 3.64 3.75 3.87 3.68 3.76 3.87 4.00
Amps 12.7 12.9 13.3 13.7 13.5 13.8 14.2 14.6 14.5 14.8 15.2 15.7 15.3 15.6 16.1 16.6 16.2 16.5 17.0 17.5 17.0 17.4 17.9 18.5
Hi PR 242 261 275 287 272 293 309 322 309 333 351 367 352 379 400 417 396 426 450 470 438 471 497 519
Lo PR 117 124 136 144 123 131 143 153 128 136 149 159 135 143 156 166 141 150 164 174 146 155 169 180
MBh 40.6 41.4 43.3 46.2 39.6 40.4 42.3 45.1 38.7 39.4 41.3 44.1 37.7 38.5 40.3 43.0 35.9 36.6 38.3 40.8 33.2 33.9 35.5 37.8
S/T 0.95 0.91 0.82 0.67 0.98 0.95 0.85 0.69 1.00 0.97 0.88 0.71 1.00 1.00 0.90 0.73 1.00 1.00 0.94 0.76 1.00 1.00 0.95 0.77
∆T 25 25 23 20 25 25 24 20 25 25 24 20 25 25 24 21 23 24 23 20 22 22 22 19
85 1410 kW 2.87 2.92 3.01 3.09 3.07 3.13 3.22 3.32 3.24 3.31 3.41 3.52 3.40 3.47 3.58 3.69 3.54 3.61 3.72 3.84 3.65 3.73 3.84 3.96
Amps 12.6 12.8 13.2 13.6 13.4 13.7 14.1 14.5 14.4 14.7 15.1 15.6 15.2 15.5 16.0 16.5 16.0 16.4 16.8 17.4 16.9 17.2 17.7 18.3
Hi PR 240 258 273 284 269 290 306 319 306 329 348 363 349 375 396 413 392 422 446 465 433 466 493 514
Lo PR 116 123 134 143 122 130 142 151 127 135 147 157 133 142 155 165 140 149 162 173 144 154 168 179
MBh 37.5 38.2 40.0 42.7 36.6 37.3 39.1 41.7 35.7 36.4 38.1 40.7 34.8 35.5 37.2 39.7 33.1 33.7 35.3 37.7 30.7 31.3 32.7 34.9
S/T 0.91 0.88 0.80 0.65 0.95 0.91 0.82 0.67 0.97 0.94 0.85 0.69 1.00 0.97 0.87 0.71 1.00 1.00 0.91 0.73 1.00 1.00 0.91 0.74
∆T 25 25 24 20 26 25 24 21 26 25 24 21 26 26 24 21 25 25 24 21 23 23 22 19
1236 kW 2.80 2.86 2.94 3.03 3.00 3.06 3.15 3.24 3.17 3.23 3.33 3.43 3.32 3.39 3.49 3.60 3.45 3.52 3.63 3.75 3.56 3.64 3.75 3.87
Amps 12.3 12.5 12.9 13.3 13.1 13.4 13.7 14.2 14.0 14.3 14.7 15.2 14.9 15.2 15.6 16.1 15.7 16.0 16.4 17.0 16.5 16.8 17.3 17.9
Hi PR 233 250 264 276 261 281 297 310 297 320 337 352 338 364 384 401 381 410 432 451 420 452 478 498
Lo PR 112 119 130 139 118 126 138 146 123 131 143 152 129 138 150 160 135 144 157 168 140 149 163 173
IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions kW = Total system power

23
High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)
Product Specifications
Outdoor Ambient Temperature

24
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
MBh 45.5 47.1 51.6 - 44.4 46.0 50.4 - 43.4 44.9 49.2 - 42.3 43.8 48.0 - 40.2 41.6 45.6 - 37.2 38.6 42.3 -
S/T 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.86 0.72 0.50 - 0.86 0.72 0.50 -
∆T 17 15 11 - 17 15 11 - 17 15 11 - 17 15 11 - 17 15 11 - 16 14 10 -
1856 kW 2.80 2.86 2.95 - 3.02 3.09 3.20 - 3.23 3.30 3.41 - 3.40 3.48 3.60 - 3.56 3.64 3.76 - 3.69 3.77 3.90 -
Amps 10.7 11.0 11.4 - 11.6 11.9 12.3 - 12.7 13.0 13.5 - 13.6 13.9 14.4 - 14.5 14.9 15.4 - 15.4 15.8 16.4 -
Hi PR 147 158 167 - 165 177 187 - 187 202 213 - 213 230 243 - 240 258 273 - 265 285 301 -
Product Specifications

Lo PR 64 68 74 - 67 71 78 - 70 74 81 - 73 78 85 - 77 82 89 - 79 85 92 -
MBh 44.1 45.8 50.1 - 43.1 44.7 49.0 - 42.1 43.6 47.8 - 41.1 42.6 46.6 - 39.0 40.4 44.3 - 36.1 37.5 41.0 -
S/T 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.79 0.66 0.46 - 0.82 0.68 0.47 - 0.82 0.69 0.48 -
∆T 18 15 12 - 18 15 12 - 18 15 12 - 18 16 12 - 18 15 12 - 17 14 11 -
70 1650 kW 2.77 2.83 2.93 - 3.00 3.07 3.17 - 3.20 3.27 3.38 - 3.37 3.45 3.57 - 3.52 3.61 3.73 - 3.65 3.74 3.87 -
Amps 10.6 10.9 11.3 - 11.5 11.8 12.2 - 12.6 12.9 13.3 - 13.5 13.8 14.3 - 14.4 14.7 15.3 - 15.3 15.7 16.2 -
Hi PR 145 156 165 - 163 176 185 - 186 200 211 - 211 227 240 - 238 256 270 - 263 283 298 -
Lo PR 63 67 73 - 66 71 77 - 69 73 80 - 73 77 84 - 76 81 88 - 79 84 91 -
MBh 40.7 42.2 46.3 - 39.8 41.2 45.2 - 38.8 40.3 44.1 - 37.9 39.3 43.0 - 36.0 37.3 40.9 - 33.4 34.6 37.9 -
S/T 0.69 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.61 0.43 - 0.76 0.63 0.44 - 0.79 0.66 0.46 - 0.80 0.66 0.46 -
∆T 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -
1444 kW 2.70 2.76 2.85 - 2.92 2.99 3.09 - 3.12 3.19 3.30 - 3.29 3.36 3.48 - 3.43 3.51 3.63 - 3.56 3.64 3.77 -
Expanded Cooling Data — GPH1348H21*

Amps 10.3 10.6 10.9 - 11.2 11.5 11.9 - 12.2 12.5 12.9 - 13.1 13.4 13.9 - 14.0 14.3 14.8 - 14.8 15.2 15.7 -
Hi PR 141 152 160 - 158 170 180 - 180 194 204 - 205 221 233 - 231 248 262 - 255 274 289 -
Lo PR 61 65 71 - 64 69 75 - 67 71 78 - 70 75 82 - 74 78 86 - 76 81 89 -

MBh 46.2 47.6 51.5 55.3 45.2 46.5 50.3 54.0 44.1 45.4 49.1 52.7 43.0 44.3 47.9 51.4 40.9 42.1 45.5 48.9 37.9 39.0 42.2 45.3
S/T 0.86 0.77 0.58 0.37 0.89 0.79 0.60 0.39 0.91 0.81 0.62 0.40 0.94 0.84 0.64 0.41 0.97 0.87 0.66 0.42 0.98 0.88 0.67 0.43
∆T 20 18 15 10 20 18 15 10 20 18 15 10 20 18 15 10 20 18 15 10 18 17 14 10

www.goodmanmfg.com
1856 kW 2.82 2.88 2.98 3.08 3.05 3.12 3.23 3.34 3.25 3.33 3.44 3.56 3.43 3.51 3.64 3.76 3.59 3.67 3.80 3.93 3.72 3.81 3.94 4.08
Amps 10.8 11.1 11.5 11.9 11.7 12.0 12.5 12.9 12.8 13.1 13.6 14.1 13.7 14.1 14.6 15.1 14.6 15.0 15.5 16.2 15.6 16.0 16.5 17.2
Hi PR 148 160 169 176 166 179 189 197 189 204 215 224 216 232 245 256 243 261 276 287 268 288 305 318
Lo PR 64 68 75 79 68 72 79 84 70 75 82 87 74 79 86 92 78 83 90 96 80 85 93 99
MBh 44.9 46.2 50.0 53.7 43.8 45.1 48.9 52.4 42.8 44.1 47.7 51.2 41.8 43.0 46.5 49.9 39.7 40.8 44.2 47.5 36.7 37.8 41.0 44.0
S/T 0.82 0.73 0.55 0.36 0.85 0.76 0.57 0.37 0.87 0.78 0.59 0.38 0.90 0.80 0.61 0.39 0.93 0.83 0.63 0.40 0.94 0.84 0.63 0.41
∆T 20 19 15 11 21 19 16 11 21 19 16 11 21 19 16 11 21 19 16 11 19 18 14 10
75 1650 kW 2.80 2.86 2.95 3.06 3.02 3.09 3.20 3.31 3.23 3.30 3.41 3.53 3.40 3.48 3.60 3.73 3.56 3.64 3.77 3.90 3.69 3.77 3.90 4.04
Amps 10.7 11.0 11.4 11.8 11.6 11.9 12.3 12.8 12.7 13.0 13.5 14.0 13.6 13.9 14.4 15.0 14.5 14.9 15.4 16.0 15.4 15.8 16.4 17.0
Hi PR 147 158 167 174 165 177 187 195 187 202 213 222 213 230 243 253 240 258 273 285 265 286 301 314
Lo PR 64 68 74 79 67 71 78 83 70 74 81 86 73 78 85 91 77 82 89 95 79 85 92 98
MBh 41.4 42.7 46.2 49.6 40.5 41.7 45.1 48.4 39.5 40.7 44.0 47.3 38.5 39.7 43.0 46.1 36.6 37.7 40.8 43.8 33.9 34.9 37.8 40.6
S/T 0.79 0.70 0.53 0.34 0.82 0.73 0.55 0.36 0.84 0.75 0.57 0.36 0.86 0.77 0.58 0.38 0.90 0.80 0.61 0.39 0.90 0.81 0.61 0.39
∆T 21 19 16 11 21 19 16 11 21 19 16 11 21 20 16 11 21 19 16 11 20 18 15 10
1444 kW 2.73 2.79 2.88 2.98 2.95 3.01 3.12 3.22 3.14 3.21 3.32 3.44 3.32 3.39 3.51 3.63 3.46 3.54 3.67 3.79 3.59 3.67 3.80 3.94
Amps 10.4 10.7 11.0 11.5 11.3 11.6 12.0 12.5 12.3 12.6 13.1 13.6 13.2 13.5 14.0 14.6 14.1 14.5 15.0 15.5 15.0 15.3 15.9 16.5
Hi PR 142 153 162 169 160 172 182 189 182 196 207 215 207 223 235 245 233 251 265 276 257 277 292 305
Lo PR 62 66 72 76 65 69 76 81 68 72 79 84 71 76 83 88 75 79 87 92 77 82 90 95
IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions kW = Total system power
High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)

SS-GPH13H
Outdoor Ambient Temperature
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71

SS-GPH13H
MBh 47.1 48.1 51.4 54.9 46.0 47.0 50.2 53.6 44.9 45.9 49.0 52.4 43.8 44.7 47.8 51.1 41.6 42.5 45.4 48.5 38.5 39.4 42.1 45.0
S/T 0.94 0.88 0.72 0.54 1.00 0.91 0.74 0.56 1.00 0.94 0.76 0.57 1.00 0.97 0.79 0.59 1.00 1.00 0.82 0.61 1.00 1.00 0.82 0.62
∆T 22 21 18 15 23 21 18 15 22 21 18 15 22 21 19 15 21 21 18 15 19 19 17 14
1856 kW 2.84 2.91 3.01 3.11 3.08 3.15 3.25 3.37 3.28 3.36 3.47 3.60 3.46 3.55 3.67 3.80 3.62 3.70 3.83 3.97 3.75 3.84 3.98 4.12
Amps 10.9 11.2 11.6 12.0 11.9 12.2 12.6 13.1 12.9 13.3 13.7 14.3 13.9 14.2 14.7 15.3 14.8 15.2 15.7 16.3 15.7 16.1 16.7 17.3
Hi PR 150 161 170 178 168 181 191 199 191 206 217 227 218 234 247 258 245 264 278 290 271 291 308 321
Lo PR 65 69 75 80 69 73 80 85 71 76 83 88 75 80 87 93 78 83 91 97 81 86 94 100
MBh 45.7 46.7 49.9 53.3 44.6 45.6 48.7 52.1 43.6 44.5 47.6 50.8 42.5 43.4 ## 49.6 40.4 41.3 44.1 47.1 37.4 38.2 40.8 43.6
S/T 0.90 0.84 0.68 0.51 0.93 0.87 0.71 0.53 0.95 0.89 0.73 0.54 0.98 0.92 0.75 0.56 1.00 0.96 0.78 0.58 1.00 0.96 0.78 0.59
∆T 23 22 19 15 23 22 19 15 23 22 19 15 23 22 19 15 22 22 19 15 21 21 18 14
80 1650 kW 2.82 2.88 2.98 3.08 3.05 3.12 3.23 3.34 3.25 3.33 3.44 3.56 3.43 3.51 ## 3.76 3.59 3.67 3.80 3.93 3.72 3.81 3.94 4.08
Amps 10.8 11.1 11.5 11.9 11.7 12.0 12.5 12.9 12.8 13.1 13.6 14.1 13.7 14.1 14.6 15.1 14.7 15.0 15.6 16.2 15.6 16.0 16.5 17.2
Hi PR 148 160 169 176 166 179 189 197 189 204 215 224 216 232 245 256 243 261 276 287 268 288 305 318
Lo PR 64 68 75 79 68 72 79 84 70 75 82 87 74 79 86 92 78 83 90 96 80 85 93 99
MBh 42.2 43.1 46.0 49.2 41.2 42.1 45.0 48.1 40.2 41.1 43.9 46.9 39.2 40.1 42.8 45.8 37.3 38.1 40.7 43.5 34.5 35.3 37.7 40.3
S/T 0.86 0.81 0.66 0.49 0.90 0.84 0.68 0.51 0.92 0.86 0.70 0.52 0.95 0.89 0.72 0.54 0.98 0.92 0.75 0.56 0.99 0.93 0.76 0.57
∆T 23 22 19 15 23 22 20 16 24 23 20 16 24 23 20 16 23 22 19 16 22 21 18 15
1444 kW 2.75 2.81 2.90 3.00 2.97 3.04 3.14 3.25 3.17 3.24 3.35 3.47 3.34 3.42 3.54 3.66 3.49 3.57 3.70 3.83 3.62 3.71 3.83 3.97
Amps 10.5 10.8 11.1 11.6 11.4 11.7 12.1 12.6 12.4 12.8 13.2 13.7 13.3 13.7 14.2 14.7 14.2 14.6 15.1 15.7 15.1 15.5 16.0 16.7
Hi PR 144 155 164 171 161 174 183 191 184 198 209 218 209 225 238 248 235 253 267 279 260 280 295 308
Lo PR 62 66 72 77 66 70 76 81 68 73 79 85 72 76 83 89 75 80 87 93 78 83 90 96
Expanded Cooling Data — GPH1348H21* (cont.)

MBh 47.9 48.8 51.1 54.5 46.8 47.7 49.9 53.3 45.7 46.5 48.7 52.0 44.5 45.4 47.6 50.7 42.3 43.1 45.2 48.2 39.2 40.0 41.8 44.6
S/T 0.98 0.95 0.86 0.70 1.00 0.98 0.89 0.72 1.00 1.00 0.91 0.74 1.00 1.00 0.94 0.76 1.00 1.00 0.98 0.79 1.00 1.00 0.98 0.80
∆T 23 23 22 19 23 23 22 19 23 23 22 19 22 22 22 19 21 21 22 19 19 20 20 18

www.goodmanmfg.com
1856 kW 2.87 2.93 3.03 3.13 3.10 3.17 3.28 3.40 3.31 3.39 3.50 3.63 3.49 3.58 3.70 3.83 3.65 3.74 3.87 4.00 3.79 3.87 4.01 4.15
Amps 11.0 11.3 11.7 12.2 12.0 12.3 12.7 13.2 13.1 13.4 13.9 14.4 14.0 14.4 14.9 15.4 14.9 15.3 15.9 16.5 15.9 16.3 16.8 17.5
Hi PR 151 163 172 179 170 183 193 201 193 208 219 229 220 237 250 261 247 266 281 293 273 294 311 324
Lo PR 65 70 76 81 69 74 80 86 72 77 84 89 76 80 88 93 79 84 92 98 82 87 95 101
MBh 46.5 47.4 49.6 52.9 45.4 46.3 48.5 51.7 44.3 45.2 47.3 50.5 43.2 44.1 46.2 49.3 41.1 41.9 43.9 46.8 38.1 38.8 40.6 43.3
S/T 0.94 0.91 0.82 0.66 0.97 0.94 0.85 0.69 1.00 0.96 0.87 0.71 1.00 0.99 0.90 0.73 1.00 1.00 0.93 0.76 1.00 1.00 0.94 0.76
∆T 24 24 23 20 25 24 23 20 25 24 23 20 24 24 23 20 23 23 23 20 21 22 21 18
85 1650 kW 2.84 2.91 3.01 3.11 3.08 3.15 3.25 3.37 3.28 3.36 3.47 3.60 3.46 3.55 3.67 3.80 3.62 3.70 3.83 3.97 3.75 3.84 3.98 4.12
Amps 10.9 11.2 11.6 12.0 11.9 12.2 12.6 13.1 12.9 13.3 13.7 14.3 13.9 14.2 14.7 15.3 14.8 15.2 15.7 16.3 15.7 16.1 16.7 17.3
Hi PR 150 161 170 178 168 181 191 199 191 206 217 227 218 234 247 258 245 264 278 290 271 291 308 321
Lo PR 65 69 75 80 69 73 80 85 71 76 83 88 75 80 87 93 78 83 91 97 81 86 94 100
MBh 42.9 43.7 45.8 48.9 41.9 42.7 44.7 47.7 40.9 41.7 43.7 46.6 39.9 40.7 42.6 45.5 37.9 38.7 40.5 43.2 35.1 35.8 37.5 40.0
S/T 0.91 0.87 0.79 0.64 0.94 0.91 0.82 0.66 0.96 0.93 0.84 0.68 0.99 0.96 0.86 0.70 1.00 0.99 0.90 0.73 1.00 1.00 0.91 0.73
∆T 25 24 23 20 25 25 23 20 25 25 23 20 25 25 23 20 24 24 23 20 22 23 22 19
1444 kW 2.77 2.83 2.93 3.03 3.00 3.07 3.17 3.28 3.20 3.27 3.38 3.50 3.37 3.45 3.57 3.70 3.52 3.61 3.73 3.86 3.65 3.74 3.87 4.01
Amps 10.6 10.9 11.3 11.7 11.5 11.8 12.2 12.7 12.6 12.9 13.3 13.8 13.5 13.8 14.3 14.8 14.4 14.7 15.2 15.8 15.3 15.6 16.2 16.8
Hi PR 145 156 165 172 163 175 185 193 185 200 211 220 211 227 240 250 238 256 270 282 263 283 298 311
Lo PR 63 67 73 78 66 71 77 82 69 73 80 85 73 77 84 90 76 81 88 94 79 84 91 97
IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions kW = Total system power

25
High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)
Product Specifications
Outdoor Ambient Temperature

26
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
MBh 45.1 46.7 51.2 - 44.0 45.6 50.0 - 43.0 44.5 48.8 - 41.9 43.5 47.6 - 39.8 41.3 45.2 - 36.9 38.2 41.9 -
S/T 0.78 0.65 0.45 - 0.81 0.67 0.47 - 0.83 0.69 0.48 - 0.85 0.71 0.49 - 0.89 0.74 0.51 - 0.89 0.75 0.52 -
∆T 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -
1800 kW 3.09 3.15 3.24 - 3.31 3.37 3.47 - 3.50 3.57 3.67 - 3.66 3.74 3.85 - 3.81 3.88 4.00 - 3.93 4.01 4.13 -
Amps 13.6 13.8 14.2 - 14.5 14.7 15.1 - 15.5 15.8 16.2 - 16.4 16.7 17.2 - 17.2 17.6 18.1 - 18.1 18.5 19.0 -
Hi PR 228 245 259 - 256 275 290 - 291 313 330 - 331 356 376 - 372 401 423 - 411 443 468 -
Product Specifications

Lo PR 109 116 127 - 116 123 134 - 120 128 139 - 126 134 146 - 132 141 154 - 137 145 159 -
MBh 43.8 45.4 49.7 - 42.7 44.3 48.5 - 41.7 43.2 47.4 - 40.7 42.2 46.2 - 38.7 40.1 43.9 - 35.8 37.1 40.7 -
S/T 0.74 0.62 0.43 - 0.77 0.64 0.45 - 0.79 0.66 0.46 - 0.81 0.68 0.47 - 0.85 0.71 0.49 - 0.85 0.71 0.49 -
∆T 19 16 12 - 19 16 12 - 19 16 12 - 19 16 13 - 19 16 12 - 18 15 12 -
70 1600 kW 3.07 3.13 3.22 - 3.28 3.35 3.44 - 3.47 3.54 3.64 - 3.64 3.71 3.82 - 3.78 3.85 3.97 - 3.90 3.98 4.10 -
Amps 13.5 13.7 14.1 - 14.4 14.6 15.0 - 15.4 15.7 16.1 - 16.2 16.6 17.0 - 17.1 17.5 18.0 - 18.0 18.3 18.9 -
Hi PR 225 243 256 - 253 272 287 - 288 310 327 - 328 353 372 - 369 397 419 - 407 438 463 -
Lo PR 108 115 126 - 114 122 133 - 119 126 138 - 125 133 145 - 131 139 152 - 135 144 157 -
MBh 40.4 41.9 45.9 - 39.5 40.9 44.8 - 38.5 39.9 43.7 - 37.6 38.9 42.7 - 35.7 37.0 40.5 - 33.1 34.3 37.5 -
S/T 0.72 0.60 0.41 - 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.79 0.66 0.45 - 0.82 0.68 0.47 - 0.82 0.69 0.48 -
∆T 19 16 12 - 19 17 13 - 19 17 13 - 19 17 13 - 19 17 13 - 18 15 12 -
1400 kW 3.01 3.06 3.15 - 3.21 3.27 3.37 - 3.39 3.46 3.56 - 3.55 3.62 3.73 - 3.69 3.76 3.88 - 3.81 3.89 4.00 -
Expanded Cooling Data — GPH1348H41*

Amps 13.2 13.4 13.8 - 14.0 14.3 14.7 - 15.0 15.3 15.7 - 15.9 16.2 16.6 - 16.7 17.1 17.5 - 17.5 17.9 18.4 -
Hi PR 219 235 249 - 245 264 279 - 279 300 317 - 318 342 361 - 358 385 406 - 395 425 449 -
Lo PR 105 112 122 - 111 118 129 - 115 123 134 - 121 129 141 - 127 135 147 - 131 140 153 -

MBh 45.8 47.2 51.1 54.8 44.8 46.1 49.9 53.6 43.7 45.0 48.7 52.3 42.6 43.9 47.5 51.0 40.5 41.7 45.1 48.5 37.5 38.6 41.8 44.9
S/T 0.88 0.79 0.60 0.39 0.92 0.82 0.62 0.40 0.94 0.84 0.64 0.41 0.97 0.87 0.66 0.42 1.00 0.90 0.68 0.44 1.00 0.91 0.69 0.44
∆T 21 19 16 11 21 19 16 11 21 19 16 11 21 19 16 11 21 19 16 11 19 18 15 10

www.goodmanmfg.com
1800 kW 3.12 3.18 3.27 3.36 3.33 3.40 3.50 3.60 3.52 3.59 3.70 3.81 3.69 3.77 3.88 4.00 3.84 3.91 4.03 4.16 3.96 4.04 4.17 4.30
Amps 13.7 13.9 14.3 14.7 14.6 14.9 15.3 15.7 15.6 15.9 16.4 16.9 16.5 16.8 17.3 17.9 17.4 17.7 18.2 18.8 18.3 18.6 19.2 19.8
Hi PR 230 248 261 273 258 278 293 306 294 316 334 348 334 360 380 396 376 405 427 446 416 447 472 493
Lo PR 110 118 128 137 117 124 136 144 121 129 141 150 127 136 148 158 134 142 155 165 138 147 160 171
MBh 44.5 45.8 49.6 53.2 43.5 44.8 48.4 52.0 42.4 43.7 47.3 50.8 41.4 42.6 46.1 49.5 39.3 40.5 43.8 47.0 36.4 37.5 40.6 43.6
S/T 0.84 0.75 0.57 0.37 0.87 0.78 0.59 0.38 0.90 0.80 0.61 0.39 0.93 0.83 0.63 0.40 0.96 0.86 0.65 0.42 0.97 0.87 0.66 0.42
∆T 22 20 16 11 22 20 16 11 22 20 16 11 22 20 17 11 22 20 16 11 20 19 15 11
75 1600 kW 3.09 3.15 3.24 3.34 3.31 3.37 3.47 3.57 3.50 3.57 3.67 3.78 3.66 3.74 3.85 3.97 3.81 3.88 4.00 4.13 3.93 4.01 4.13 4.26
Amps 13.6 13.8 14.2 14.6 14.5 14.7 15.1 15.6 15.5 15.8 16.2 16.7 16.4 16.7 17.2 17.7 17.2 17.6 18.1 18.7 18.1 18.5 19.0 19.6
Hi PR 228 245 259 270 256 275 290 303 291 313 330 345 331 356 376 392 372 401 423 441 412 443 468 488
Lo PR 109 116 127 135 116 123 134 143 120 128 139 149 126 134 147 156 132 141 154 164 137 145 159 169
MBh 41.1 42.3 45.8 49.1 40.1 41.3 44.7 48.0 39.2 40.3 43.7 46.8 38.2 39.3 42.6 45.7 36.3 37.4 40.5 43.4 33.6 34.6 37.5 40.2
S/T 0.81 0.73 0.55 0.35 0.84 0.75 0.57 0.37 0.86 0.77 0.59 0.38 0.89 0.80 0.60 0.39 0.93 0.83 0.63 0.40 0.93 0.84 0.63 0.41
∆T 22 20 17 11 22 20 17 12 22 20 17 12 22 21 17 12 22 20 17 12 21 19 16 11
1400 kW 3.03 3.08 3.17 3.26 3.23 3.30 3.39 3.49 3.42 3.49 3.59 3.70 3.58 3.65 3.76 3.88 3.72 3.79 3.91 4.03 3.84 3.92 4.04 4.16
Amps 13.3 13.5 13.9 14.3 14.1 14.4 14.8 15.3 15.1 15.4 15.9 16.4 16.0 16.3 16.8 17.3 16.8 17.2 17.7 18.2 17.7 18.0 18.6 19.2
Hi PR 221 238 251 262 248 267 282 294 282 303 320 334 321 346 365 381 361 389 411 428 399 430 454 473
Lo PR 106 113 123 131 112 119 130 139 116 124 135 144 122 130 142 151 128 136 149 159 133 141 154 164
IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions kW = Total system power
High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)

SS-GPH13H
Outdoor Ambient Temperature
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71

SS-GPH13H
MBh 46.7 47.7 50.9 54.4 45.6 46.6 49.7 53.2 44.5 45.5 48.6 51.9 43.4 44.3 47.4 50.6 41.2 42.1 45.0 48.1 38.2 39.0 41.7 44.6
S/T 0.97 0.91 0.74 0.55 1.00 0.94 0.77 0.57 1.00 0.97 0.79 0.59 1.00 1.00 0.81 0.61 1.00 1.00 0.84 0.63 1.00 1.00 0.85 0.64
∆T 23 22 19 15 23 22 20 16 23 22 20 16 22 23 20 16 21 22 19 15 20 20 18 14
1800 kW 3.14 3.20 3.29 3.39 3.36 3.42 3.52 3.63 3.55 3.62 3.73 3.84 3.72 3.80 3.91 4.03 3.86 3.94 4.07 4.19 3.99 4.07 4.20 4.33
Amps 13.8 14.0 14.4 14.9 14.7 15.0 15.4 15.9 15.7 16.0 16.5 17.0 16.6 17.0 17.4 18.0 17.5 17.9 18.4 19.0 18.4 18.8 19.3 20.0
Hi PR 232 250 264 275 261 281 296 309 297 319 337 351 338 363 384 400 380 409 432 450 420 452 477 498
Lo PR 112 119 130 138 118 125 137 146 123 130 142 152 129 137 149 159 135 143 157 167 140 148 162 173
MBh 45.3 46.3 49.5 52.9 44.2 45.2 48.3 51.6 43.2 44.1 47.2 50.4 42.1 43.1 46.0 49.2 40.0 40.9 43.7 46.7 37.1 37.9 40.5 43.3
S/T 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 0.98 0.92 0.75 0.56 1.00 0.95 0.78 0.58 1.00 0.99 0.80 0.60 1.00 1.00 0.81 0.61
∆T 24 23 20 16 24 23 20 16 24 23 20 16 24 24 20 16 23 23 20 16 21 22 19 15
80 1600 kW 3.12 3.18 3.27 3.36 3.33 3.40 3.50 3.60 3.52 3.59 3.70 3.81 3.69 3.77 3.88 4.00 3.84 3.91 4.03 4.16 3.96 4.04 4.17 4.30
Amps 13.7 13.9 14.3 14.7 14.6 14.9 15.3 15.7 15.6 15.9 16.4 16.9 16.5 16.8 17.3 17.9 17.4 17.7 18.2 18.8 18.3 18.6 19.2 19.8
Hi PR 230 248 261 273 258 278 293 306 294 316 334 348 334 360 380 396 376 405 428 446 416 447 472 493
Lo PR 110 118 128 137 117 124 136 144 121 129 141 150 127 136 148 158 134 142 155 165 138 147 160 171
MBh 41.8 42.7 45.6 48.8 40.8 41.7 44.6 47.7 39.9 40.7 43.5 46.5 38.9 39.7 42.5 45.4 36.9 37.8 40.3 43.1 34.2 35.0 37.4 39.9
S/T 0.89 0.84 0.68 0.51 0.92 0.87 0.71 0.53 0.95 0.89 0.72 0.54 0.98 0.92 0.75 0.56 1.02 0.95 0.78 0.58 1.02 0.96 0.78 0.58
∆T 25 23 20 16 25 24 21 17 25 24 21 17 25 24 21 17 25 24 21 16 23 22 19 15
1400 kW 3.05 3.11 3.19 3.29 3.26 3.32 3.42 3.52 3.44 3.51 3.62 3.73 3.61 3.68 3.79 3.91 3.75 3.82 3.94 4.06 3.87 3.95 4.07 4.19
Amps 13.4 13.6 14.0 14.4 14.3 14.5 14.9 15.4 15.2 15.6 16.0 16.5 16.1 16.4 16.9 17.4 17.0 17.3 17.8 18.4 17.8 18.2 18.7 19.3
Hi PR 223 240 254 265 250 269 285 297 285 306 324 338 324 349 369 384 365 393 415 433 403 434 458 478
Lo PR 107 114 124 133 113 120 132 140 118 125 137 146 124 132 144 153 130 138 150 160 134 143 156 166
Expanded Cooling Data — GPH1348H41* (cont.)

MBh 47.5 48.4 50.7 54.1 46.4 47.3 49.5 52.8 45.3 46.1 48.3 51.6 44.2 45.0 47.1 50.3 42.0 42.8 44.8 47.8 38.9 39.6 41.5 44.3
S/T 1.00 0.98 0.89 0.72 1.00 1.00 0.92 0.74 1.00 1.00 0.94 0.76 1.00 1.00 0.97 0.79 1.00 1.00 1.00 0.82 1.00 1.00 1.00 0.83
∆T 24 24 23 20 24 24 23 20 23 24 23 20 23 23 23 20 21 22 23 20 20 20 21 19

www.goodmanmfg.com
1800 kW 3.16 3.22 3.31 3.41 3.38 3.45 3.55 3.66 3.58 3.65 3.76 3.87 3.75 3.82 3.94 4.06 3.89 3.98 4.10 4.23 4.02 4.10 4.23 4.37
Amps 13.9 14.2 14.5 15.0 14.8 15.1 15.5 16.0 15.8 16.2 16.6 17.1 16.7 17.1 17.6 18.1 17.7 18.0 18.5 19.1 18.5 18.9 19.5 20.1
Hi PR 235 253 267 278 263 283 299 312 300 322 340 355 341 367 388 404 384 413 436 455 424 456 482 503
Lo PR 113 120 131 139 119 127 138 147 124 132 144 153 130 138 151 161 136 145 158 169 141 150 164 174
MBh 46.1 47.0 49.2 52.5 45.0 45.9 48.1 51.3 43.9 44.8 46.9 50.1 42.9 43.7 45.8 48.8 40.7 41.5 43.5 46.4 37.7 38.5 40.3 43.0
S/T 0.97 0.94 0.84 0.69 1.00 0.97 0.88 0.71 1.00 0.99 0.90 0.73 1.00 1.00 0.93 0.75 1.00 1.00 0.96 0.78 1.00 1.00 0.97 0.79
∆T 26 25 24 21 26 26 24 21 25 26 24 21 25 25 24 21 23 24 24 21 22 22 22 19
85 1600 kW 3.14 3.20 3.29 3.39 3.36 3.42 3.52 3.63 3.55 3.62 3.73 3.84 3.72 3.80 3.91 4.03 3.86 3.94 4.07 4.19 3.99 4.07 4.20 4.33
Amps 13.8 14.0 14.4 14.9 14.7 15.0 15.4 15.9 15.7 16.0 16.5 17.0 16.6 17.0 17.4 18.0 17.5 17.9 18.4 19.0 18.4 18.8 19.3 20.0
Hi PR 232 250 264 275 261 281 296 309 297 319 337 351 338 363 384 400 380 409 432 450 420 452 477 498
Lo PR 112 119 130 138 118 125 137 146 123 130 142 152 129 137 149 159 135 143 157 167 140 148 162 173
MBh 42.5 43.4 45.4 48.5 41.5 42.4 44.4 47.3 40.6 41.3 43.3 46.2 39.6 40.3 42.2 45.1 37.6 38.3 40.1 42.8 34.8 35.5 37.2 39.7
S/T 0.94 0.90 0.81 0.66 0.97 0.94 0.84 0.69 0.99 0.96 0.87 0.70 1.00 0.99 0.89 0.73 1.00 1.00 0.93 0.75 1.00 1.00 0.94 0.76
∆T 26 26 24 21 26 26 25 21 26 26 25 21 26 26 25 21 25 25 24 21 23 23 23 20
1400 kW 3.07 3.13 3.22 3.31 3.28 3.35 3.44 3.55 3.47 3.54 3.64 3.75 3.63 3.71 3.82 3.94 3.78 3.85 3.97 4.09 3.90 3.98 4.10 4.23
Amps 13.5 13.7 14.1 14.5 14.4 14.6 15.0 15.5 15.4 15.7 16.1 16.6 16.2 16.6 17.0 17.6 17.1 17.5 18.0 18.5 18.0 18.3 18.9 19.5
Hi PR 225 243 256 267 253 272 287 300 288 310 327 341 328 353 372 388 369 397 419 437 407 438 463 483
Lo PR 108 115 126 134 114 122 133 141 119 126 138 147 125 133 145 154 131 139 152 162 135 144 157 167
IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions kW = Total system power

27
High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)
Product Specifications
Outdoor Ambient Temperature

28
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
MBh 56.4 58.5 64.1 - 55.1 57.1 62.6 - 53.8 55.8 61.1 - 52.5 54.4 59.6 - 49.9 51.7 56.6 - 46.2 47.9 52.5 -
S/T 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.86 0.72 0.50 - 0.86 0.72 0.50 -
∆T 18 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -
2138 kW 3.65 3.74 3.87 - 3.96 4.06 4.20 - 4.24 4.34 4.49 - 4.48 4.59 4.75 - 4.69 4.80 4.97 - 4.86 4.98 5.16 -
Amps 14.1 14.5 15.0 - 15.3 15.7 16.3 - 16.8 17.2 17.8 - 18.0 18.4 19.1 - 19.2 19.7 20.4 - 20.4 20.9 21.7 -
Hi PR 159 171 180 - 178 192 202 - 203 218 230 - 231 248 262 - 260 279 295 - 287 309 326 -
Product Specifications

Lo PR 61 65 71 - 65 69 75 - 67 72 78 - 71 75 82 - 74 79 86 - 77 82 89 -
MBh 54.8 56.8 62.2 - 53.5 55.5 60.8 - 52.3 54.2 59.3 - 51.0 52.8 57.9 - 48.4 50.2 55.0 - 44.9 46.5 50.9 -
S/T 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.79 0.66 0.46 - 0.82 0.68 0.47 - 0.82 0.69 0.48 -
∆T 19 16 13 - 19 17 13 - 19 17 13 - 19 17 13 - 19 17 13 - 18 15 12 -
70 1900 kW 3.62 3.70 3.83 - 3.93 4.02 4.16 - 4.20 4.30 4.45 - 4.44 4.55 4.71 - 4.64 4.76 4.93 - 4.82 4.94 5.11 -
Amps 14.0 14.3 14.8 - 15.2 15.6 16.1 - 16.6 17.0 17.6 - 17.8 18.3 18.9 - 19.0 19.5 20.2 - 20.2 20.7 21.4 -
Hi PR 157 169 179 - 176 190 200 - 201 216 228 - 229 246 260 - 257 277 292 - 284 306 323 -
Lo PR 61 65 71 - 64 68 75 - 67 71 77 - 70 75 81 - 73 78 85 - 76 81 88 -
MBh 50.6 52.4 57.4 - 49.4 51.2 56.1 - 48.2 50.0 54.8 - 47.1 48.8 53.4 - 44.7 46.3 50.8 - 41.4 42.9 47.0 -
S/T 0.69 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.61 0.43 - 0.76 0.63 0.44 - 0.79 0.66 0.46 - 0.80 0.66 0.46 -
∆T 19 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 19 17 13 - 18 16 12 -
1663 kW 3.52 3.61 3.73 - 3.82 3.91 4.05 - 4.09 4.18 4.33 - 4.32 4.42 4.58 - 4.52 4.63 4.79 - 4.69 4.80 4.97 -
Expanded Cooling Data — GPH1360H21*

Amps 13.6 13.9 14.4 - 14.8 15.1 15.7 - 16.1 16.5 17.1 - 17.3 17.7 18.3 - 18.4 18.9 19.6 - 19.6 20.1 20.8 -
Hi PR 153 164 173 - 171 184 194 - 195 209 221 - 222 239 252 - 249 268 283 - 276 297 313 -
Lo PR 59 63 68 - 62 66 72 - 65 69 75 - 68 72 79 - 71 76 83 - 74 78 86 -

MBh 57.4 59.1 64.0 68.7 56.1 57.7 62.5 67.1 54.7 56.4 61.0 65.5 53.4 55.0 59.5 63.9 50.7 52.2 56.5 60.7 47.0 48.4 52.4 56.2
S/T 0.86 0.77 0.58 0.37 0.89 0.79 0.60 0.39 0.91 0.81 0.62 0.40 0.94 0.84 0.64 0.41 0.97 0.87 0.66 0.42 0.98 0.88 0.67 0.43
∆T 21 19 16 11 21 20 16 11 21 20 16 11 22 20 16 11 21 20 16 11 20 18 15 10

www.goodmanmfg.com
2138 kW 3.68 3.77 3.90 4.04 4.00 4.09 4.24 4.39 4.28 4.38 4.53 4.70 4.52 4.63 4.80 4.97 4.73 4.84 5.02 5.20 4.91 5.03 5.21 5.40
Amps 14.3 14.6 15.1 15.7 15.5 15.9 16.4 17.1 16.9 17.4 18.0 18.7 18.1 18.6 19.3 20.0 19.4 19.9 20.6 21.4 20.6 21.1 21.9 22.7
Hi PR 160 173 182 190 180 194 205 213 205 220 233 243 233 251 265 276 262 282 298 311 290 312 329 344
Lo PR 62 66 72 77 65 70 76 81 68 72 79 84 71 76 83 88 75 80 87 93 77 82 90 96
MBh 55.7 57.4 62.1 66.7 54.4 56.0 60.7 65.1 53.1 54.7 59.2 63.6 51.8 53.4 57.8 62.0 49.2 50.7 54.9 58.9 45.6 47.0 50.8 54.6
S/T 0.82 0.73 0.55 0.36 0.85 0.76 0.57 0.37 0.87 0.78 0.59 0.38 0.90 0.80 0.61 0.39 0.93 0.83 0.63 0.40 0.94 0.84 0.63 0.41
∆T 22 20 17 11 22 21 17 12 22 21 17 12 22 21 17 12 22 20 17 12 21 19 16 11
75 1900 kW 3.65 3.74 3.87 4.00 3.96 4.06 4.20 4.35 4.24 4.34 4.49 4.66 4.48 4.59 4.75 4.93 4.69 4.80 4.97 5.15 4.86 4.98 5.16 5.35
Amps 14.1 14.5 15.0 15.6 15.3 15.7 16.3 16.9 16.8 17.2 17.8 18.5 18.0 18.4 19.1 19.8 19.2 19.7 20.4 21.2 20.4 20.9 21.7 22.5
Hi PR 159 171 180 188 178 192 203 211 203 218 230 240 231 248 262 274 260 280 295 308 287 309 326 340
Lo PR 61 65 71 76 65 69 75 80 67 72 78 83 71 75 82 88 74 79 86 92 77 82 89 95
MBh 51.4 53.0 57.3 61.5 50.2 51.7 56.0 60.1 49.0 50.5 54.7 58.7 47.8 49.3 53.3 57.2 45.5 46.8 50.7 54.4 42.1 43.4 46.9 50.4
S/T 0.79 0.70 0.53 0.34 0.82 0.73 0.55 0.36 0.84 0.75 0.57 0.36 0.86 0.77 0.58 0.38 0.90 0.80 0.61 0.39 0.90 0.81 0.61 0.39
∆T 22 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 21 19 16 11
1663 kW 3.55 3.64 3.76 3.90 3.86 3.95 4.09 4.23 4.12 4.22 4.37 4.53 4.36 4.46 4.62 4.79 4.56 4.67 4.84 5.01 4.73 4.85 5.02 5.20
Amps 13.7 14.1 14.6 15.1 14.9 15.3 15.8 16.4 16.3 16.7 17.3 18.0 17.5 17.9 18.5 19.3 18.6 19.1 19.8 20.6 19.8 20.3 21.0 21.9
Hi PR 154 166 175 183 173 186 196 205 197 212 223 233 224 241 254 265 252 271 286 299 278 300 316 330
Lo PR 59 63 69 74 63 67 73 78 65 70 76 81 69 73 80 85 72 77 84 89 74 79 86 92
IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions kW = Total system power
High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)

SS-GPH13H
Outdoor Ambient Temperature
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71

SS-GPH13H
MBh 58.4 59.7 63.8 68.2 57.1 58.3 62.3 66.6 55.7 56.9 60.8 65.0 54.3 55.5 59.3 63.4 51.6 52.8 56.4 60.3 47.8 48.9 52.2 55.8
S/T 0.94 0.88 0.72 0.54 1.00 0.91 0.74 0.56 1.00 0.94 0.76 0.57 1.00 0.97 0.79 0.59 1.00 1.00 0.82 0.61 1.00 1.00 0.82 0.62
∆T 24 23 20 16 25 23 20 16 24 23 20 16 23 23 20 16 22 23 20 16 21 21 18 15
2138 kW 3.72 3.80 3.94 4.08 4.03 4.13 4.28 4.43 4.31 4.42 4.58 4.74 4.56 4.67 4.84 5.02 4.77 4.89 5.06 5.25 4.95 5.07 5.26 5.45
Amps 14.4 14.8 15.3 15.9 15.6 16.0 16.6 17.3 17.1 17.5 18.1 18.9 18.3 18.8 19.5 20.2 19.6 20.1 20.8 21.6 20.8 21.3 22.1 23.0
Hi PR 162 174 184 192 182 196 207 216 207 223 235 245 236 253 268 279 265 285 301 314 293 315 333 347
Lo PR 63 67 73 77 66 70 77 82 69 73 80 85 72 77 84 89 76 80 88 94 78 83 91 97
MBh 56.7 58.0 61.9 66.2 55.4 56.6 60.5 64.7 54.1 55.3 59.0 63.1 52.8 53.9 57.6 61.6 50.1 51.2 54.7 58.5 46.4 47.4 50.7 54.2
S/T 0.90 0.84 0.68 0.51 0.93 0.87 0.71 0.53 0.95 0.89 0.73 0.54 0.98 0.92 0.75 0.56 1.00 0.96 0.78 0.58 1.00 0.96 0.78 0.59
∆T 25 24 20 16 25 24 21 17 25 24 21 17 25 24 21 17 24 24 21 16 22 22 19 15
80 1900 kW 3.68 3.77 3.90 4.04 4.00 4.09 4.24 4.39 4.28 4.38 4.53 4.70 4.52 4.63 ## 4.97 4.73 4.84 5.02 5.20 4.91 5.03 5.21 5.40
Amps 14.3 14.6 15.1 15.7 15.5 15.9 16.4 17.1 16.9 17.4 18.0 18.7 18.1 18.6 19.3 20.0 19.4 19.9 20.6 21.4 20.6 21.1 21.9 22.7
Hi PR 160 173 182 190 180 194 205 213 205 220 233 243 233 251 265 276 262 282 298 311 290 312 329 344
Lo PR 62 66 72 77 65 70 76 81 68 72 79 84 71 76 83 88 75 80 87 93 77 82 90 96
MBh 52.4 53.5 57.2 61.1 51.1 52.3 55.8 59.7 49.9 51.0 54.5 58.3 48.7 49.8 53.2 56.8 46.3 47.3 50.5 54.0 42.9 43.8 46.8 50.0
S/T 0.86 0.81 0.66 0.49 0.90 0.84 0.68 0.51 0.92 0.86 0.70 0.52 0.95 0.89 0.72 0.54 0.98 0.92 0.75 0.56 0.99 0.93 0.76 0.57
∆T 25 24 21 17 25 24 21 17 25 24 21 17 26 24 21 17 25 24 21 17 23 23 20 16
1663 kW 3.59 3.67 3.80 3.93 3.89 3.98 4.12 4.27 4.16 4.26 4.41 4.57 4.40 4.50 4.67 4.83 4.60 4.71 4.88 5.06 4.78 4.89 5.07 5.25
Amps 13.9 14.2 14.7 15.3 15.0 15.4 16.0 16.6 16.4 16.8 17.4 18.1 17.6 18.1 18.7 19.5 18.8 19.3 20.0 20.8 20.0 20.5 21.2 22.1
Hi PR 156 167 177 184 175 188 198 207 199 214 226 235 226 243 257 268 254 274 289 302 281 303 320 333
Lo PR 60 64 70 74 63 68 74 79 66 70 77 82 69 74 81 86 73 77 84 90 75 80 87 93
Expanded Cooling Data — GPH1360H21* (cont.)

MBh 59.4 60.6 63.5 67.7 58.1 59.2 62.0 66.1 56.7 57.8 60.5 64.6 55.3 56.4 59.0 63.0 52.5 53.5 56.1 59.8 48.7 49.6 51.9 55.4
S/T 0.98 0.95 0.86 0.70 1.00 0.98 0.89 0.72 1.00 1.00 0.91 0.74 1.00 1.00 0.94 0.76 1.00 1.00 0.98 0.79 1.00 1.00 0.98 0.80
∆T 25 25 23 20 25 25 24 21 24 25 24 21 24 24 24 21 23 23 24 20 21 21 22 19

www.goodmanmfg.com
2138 kW 3.75 3.84 3.97 4.11 4.07 4.17 4.31 4.47 4.35 4.46 4.62 4.78 4.60 4.71 4.88 5.06 4.82 4.93 5.11 5.30 5.00 5.12 5.31 5.50
Amps 14.5 14.9 15.4 16.0 15.8 16.2 16.8 17.4 17.2 17.7 18.3 19.0 18.5 19.0 19.6 20.4 19.8 20.3 21.0 21.8 21.0 21.5 22.3 23.2
Hi PR 164 176 186 194 184 198 209 218 209 225 237 248 238 256 270 282 268 288 304 317 296 318 336 350
Lo PR 63 67 73 78 67 71 78 83 69 74 81 86 73 78 85 90 76 81 89 94 79 84 92 98
MBh 57.7 58.8 61.6 65.7 56.4 57.5 60.2 64.2 55.0 56.1 58.7 62.7 53.7 54.7 57.3 61.1 51.0 52.0 54.4 58.1 47.2 48.2 50.4 53.8
S/T 0.94 0.91 0.82 0.66 0.97 0.94 0.85 0.69 1.00 0.96 0.87 0.71 1.00 0.99 0.90 0.73 1.00 1.00 0.93 0.76 1.00 1.00 0.94 0.76
∆T 26 26 24 21 27 26 25 21 27 26 25 21 26 26 25 22 25 25 25 21 23 23 23 20
85 1900 kW 3.72 3.80 3.94 4.08 4.03 4.13 4.28 4.43 4.31 4.42 4.58 4.74 4.56 4.67 4.84 5.02 4.77 4.89 5.06 5.25 4.95 5.07 5.26 5.45
Amps 14.4 14.8 15.3 15.9 15.6 16.0 16.6 17.3 17.1 17.5 18.1 18.9 18.3 18.8 19.5 20.2 19.6 20.1 20.8 21.6 20.8 21.3 22.1 23.0
Hi PR 162 174 184 192 182 196 207 216 207 223 235 245 236 253 268 279 265 285 301 314 293 315 333 347
Lo PR 63 67 73 77 66 70 77 82 69 73 80 85 72 77 84 89 76 80 88 94 78 83 91 97
MBh 53.3 54.3 56.9 60.7 52.0 53.0 55.5 59.3 50.8 51.8 54.2 57.8 49.5 50.5 52.9 56.4 47.1 48.0 50.3 53.6 43.6 44.4 46.6 49.7
S/T 0.91 0.87 0.79 0.64 0.94 0.91 0.82 0.66 0.96 0.93 0.84 0.68 0.99 0.96 0.86 0.70 1.00 0.99 0.90 0.73 1.00 1.00 0.91 0.73
∆T 27 26 25 21 27 27 25 22 27 27 25 22 27 27 25 22 26 26 25 22 24 25 23 20
1663 kW 3.62 3.70 3.83 3.97 3.93 4.02 4.16 4.31 4.20 4.30 4.45 4.61 4.44 4.55 4.71 4.88 4.64 4.75 4.93 5.10 4.82 4.94 5.11 5.30
Amps 14.0 14.3 14.8 15.4 15.2 15.6 16.1 16.8 16.6 17.0 17.6 18.3 17.8 18.2 18.9 19.6 19.0 19.5 20.2 21.0 20.2 20.7 21.4 22.3
Hi PR 157 169 179 186 176 190 200 209 201 216 228 238 228 246 260 271 257 277 292 305 284 306 323 337
Lo PR 61 65 71 75 64 68 74 79 67 71 77 82 70 74 81 87 73 78 85 91 76 81 88 94
IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions kW = Total system power

29
High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)
Product Specifications
Outdoor Ambient Temperature

30
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
MBh 56.3 58.4 64.0 - 55.0 57.0 62.5 - 53.7 55.7 61.0 - 52.4 54.3 59.5 - 49.8 51.6 56.5 - 46.1 47.8 52.4 -
S/T 0.75 0.62 0.43 - 0.77 0.65 0.45 - 0.79 0.66 0.46 - 0.82 0.68 0.47 - 0.85 0.71 0.49 - 0.86 0.71 0.50 -
∆T 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 17 15 11 -
2079 kW 3.85 3.93 4.06 - 4.15 4.24 4.37 - 4.41 4.50 4.65 - 4.64 4.74 4.89 - 4.83 4.94 5.10 - 5.00 5.11 5.28 -
Amps 16.2 16.5 17.0 - 17.4 17.7 18.3 - 18.7 19.1 19.7 - 19.9 20.3 20.9 - 21.0 21.5 22.2 - 22.2 22.7 23.4 -
Hi PR 233 250 264 - 261 281 296 - 297 319 337 - 338 364 384 - 380 409 432 - 420 452 477 -
Product Specifications

Lo PR 107 114 124 - 113 120 131 - 118 125 137 - 124 131 144 - 130 138 150 - 134 143 156 -
MBh 54.7 56.7 62.1 - 53.4 55.4 60.7 - 52.2 54.1 59.2 - 50.9 52.7 57.8 - 48.3 50.1 54.9 - 44.8 46.4 50.9 -
S/T 0.71 0.59 0.41 - 0.74 0.62 0.43 - 0.76 0.63 0.44 - 0.78 0.65 0.45 - 0.81 0.68 0.47 - 0.82 0.68 0.47 -
∆T 19 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 19 17 13 - 18 16 12 -
70 1850 kW 3.82 3.90 4.03 - 4.11 4.20 4.34 - 4.37 4.47 4.61 - 4.60 4.70 4.85 - 4.79 4.90 5.06 - 4.96 5.07 5.23 -
Amps 16.1 16.4 16.9 - 17.2 17.6 18.1 - 18.5 19.0 19.5 - 19.7 20.1 20.7 - 20.8 21.3 22.0 - 22.0 22.5 23.2 -
Hi PR 230 248 262 - 258 278 294 - 294 316 334 - 335 360 380 - 376 405 428 - 416 448 473 -
Lo PR 106 113 123 - 112 119 130 - 116 124 135 - 122 130 142 - 128 136 149 - 133 141 154 -
MBh 50.5 52.3 57.3 - 49.3 51.1 56.0 - 48.1 49.9 54.7 - 47.0 48.7 53.3 - 44.6 46.2 50.7 - 41.3 42.8 46.9 -
S/T 0.69 0.57 0.40 - 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.79 0.66 0.46 -
∆T 20 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 18 16 12 -
1621 kW 3.73 3.81 3.93 - 4.02 4.10 4.23 - 4.27 4.36 4.50 - 4.48 4.58 4.73 - 4.67 4.77 4.93 - 4.83 4.94 5.10 -
Expanded Cooling Data — GPH1360H41*

Amps 15.7 16.0 16.5 - 16.8 17.2 17.7 - 18.1 18.5 19.0 - 19.2 19.6 20.2 - 20.3 20.8 21.4 - 21.4 21.9 22.6 -
Hi PR 223 240 254 - 251 270 285 - 285 307 324 - 325 349 369 - 365 393 415 - 403 434 458 -
Lo PR 103 109 120 - 109 116 126 - 113 120 131 - 119 126 138 - 124 132 144 - 129 137 149 -

MBh 57.3 59.0 63.9 68.5 56.0 57.6 62.4 66.9 54.6 56.3 60.9 65.3 53.3 54.9 59.4 63.8 50.6 52.1 56.4 60.6 46.9 48.3 52.3 56.1
S/T 0.85 0.76 0.57 0.37 0.88 0.79 0.59 0.38 0.90 0.81 0.61 0.39 0.93 0.83 0.63 0.40 0.97 0.86 0.65 0.42 0.97 0.87 0.66 0.42
∆T 21 20 16 11 22 20 16 11 22 20 16 11 22 20 17 11 22 20 16 11 20 19 15 11

www.goodmanmfg.com
2079 kW 3.89 3.97 4.09 4.22 4.18 4.27 4.41 4.55 4.44 4.54 4.69 4.84 4.67 4.78 4.93 5.10 4.87 4.98 5.14 5.32 5.04 5.15 5.32 5.50
Amps 16.3 16.7 17.2 17.7 17.5 17.9 18.4 19.0 18.9 19.3 19.9 20.5 20.0 20.5 21.1 21.8 21.2 21.7 22.3 23.1 22.4 22.9 23.6 24.4
Hi PR 235 253 267 278 264 284 300 312 300 323 341 355 341 367 388 405 384 413 436 455 424 457 482 503
Lo PR 108 115 126 134 114 122 133 141 119 126 138 147 125 133 145 154 131 139 152 162 135 144 157 167
MBh 55.6 57.3 62.0 66.5 54.3 55.9 60.6 65.0 53.0 54.6 59.1 63.4 51.8 53.3 57.7 61.9 49.2 50.6 54.8 58.8 45.5 46.9 50.8 54.5
S/T 0.81 0.72 0.55 0.35 0.84 0.75 0.57 0.36 0.86 0.77 0.58 0.37 0.89 0.79 0.60 0.39 0.92 0.82 0.62 0.40 0.93 0.83 0.63 0.40
∆T 22 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 22 21 17 12 21 19 16 11
75 1850 kW 3.85 3.94 4.06 4.19 4.15 4.24 4.37 4.51 4.41 4.50 4.65 4.80 4.64 4.74 4.89 5.06 4.83 4.94 5.10 5.27 5.00 5.11 5.28 5.46
Amps 16.2 16.5 17.0 17.6 17.4 17.7 18.3 18.9 18.7 19.1 19.7 20.4 19.9 20.3 20.9 21.6 21.0 21.5 22.2 22.9 22.2 22.7 23.4 24.2
Hi PR 233 250 264 276 261 281 297 309 297 319 337 352 338 364 384 401 380 409 432 451 420 452 477 498
Lo PR 107 114 124 133 113 120 131 140 118 125 137 146 124 131 144 153 130 138 150 160 134 143 156 166
MBh 51.3 52.9 57.2 61.4 50.2 51.6 55.9 60.0 49.0 50.4 54.6 58.6 47.8 49.2 53.2 57.1 45.4 46.7 50.6 54.3 42.0 43.3 46.8 50.3
S/T 0.78 0.70 0.53 0.34 0.81 0.72 0.55 0.35 0.83 0.74 0.56 0.36 0.86 0.76 0.58 0.37 0.89 0.79 0.60 0.39 0.89 0.80 0.61 0.39
∆T 23 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 21 20 16 11
1621 kW 3.76 3.84 3.96 4.09 4.05 4.13 4.27 4.40 4.30 4.39 4.53 4.68 4.52 4.62 4.77 4.93 4.71 4.81 4.97 5.14 4.87 4.98 5.15 5.32
Amps 15.8 16.1 16.6 17.2 16.9 17.3 17.8 18.4 18.2 18.6 19.2 19.8 19.4 19.8 20.4 21.1 20.5 20.9 21.6 22.3 21.6 22.1 22.8 23.6
Hi PR 226 243 256 267 253 272 288 300 288 310 327 341 328 353 373 389 369 397 419 437 408 439 463 483
Lo PR 104 111 121 129 110 117 128 136 114 121 133 141 120 128 139 148 126 134 146 155 130 138 151 161
IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions kW = Total system power
High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)

SS-GPH13H
Outdoor Ambient Temperature
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71

SS-GPH13H
MBh 58.3 59.6 63.7 68.1 57.0 58.2 62.2 66.5 55.6 56.8 60.7 64.9 54.3 55.4 59.2 63.3 51.5 52.7 56.3 60.1 47.7 48.8 52.1 55.7
S/T 0.93 0.87 0.71 0.53 0.96 0.90 0.74 0.55 1.00 0.93 0.75 0.56 1.00 0.96 0.78 0.58 1.00 1.00 0.81 0.60 1.00 1.00 0.81 0.61
∆T 24 23 20 16 24 23 20 16 25 23 20 16 24 23 20 16 23 23 20 16 21 22 19 15
2079 kW 3.92 4.00 4.12 4.26 4.22 4.31 4.44 4.59 4.48 4.58 4.73 4.88 4.71 4.82 4.98 5.14 4.91 5.02 5.19 5.36 5.08 5.20 5.37 5.55
Amps 16.5 16.8 17.3 17.9 17.6 18.0 18.6 19.2 19.0 19.4 20.0 20.7 20.2 20.6 21.3 22.0 21.4 21.9 22.5 23.3 22.5 23.1 23.8 24.6
Hi PR 237 255 270 281 266 286 303 316 303 326 344 359 345 371 392 409 388 417 441 460 429 461 487 508
Lo PR 109 116 127 135 116 123 134 143 120 128 139 148 126 134 146 156 132 141 153 163 137 145 159 169
MBh 56.6 57.9 61.8 66.1 55.3 56.5 60.4 64.5 54.0 55.2 58.9 63.0 52.7 53.8 57.5 61.5 50.0 51.1 54.6 58.4 46.3 47.4 50.6 54.1
S/T 0.89 0.83 0.68 0.51 0.92 0.86 0.70 0.52 0.94 0.88 0.72 0.54 0.97 0.91 0.74 0.55 1.00 0.95 0.77 0.58 1.00 0.95 0.78 0.58
∆T 25 24 21 17 25 24 21 17 25 24 21 17 25 24 21 17 25 24 21 17 23 22 20 16
80 1850 kW 3.89 3.97 4.09 4.22 4.18 4.27 4.41 4.55 4.44 4.54 4.69 4.84 4.68 4.78 4.93 5.10 4.87 4.98 5.14 5.32 5.04 5.15 5.32 5.50
Amps 16.3 16.7 17.2 17.7 17.5 17.9 18.4 19.0 18.9 19.3 19.9 20.5 20.0 20.5 21.1 21.8 21.2 21.7 22.3 23.1 22.4 22.9 23.6 24.4
Hi PR 235 253 267 278 264 284 300 312 300 323 341 355 341 367 388 405 384 413 437 455 424 457 482 503
Lo PR 108 115 126 134 114 122 133 141 119 126 138 147 125 133 145 154 131 139 152 162 135 144 157 167
MBh 52.3 53.4 57.1 61.0 51.0 52.2 55.7 59.6 49.8 50.9 54.4 58.2 48.6 49.7 53.1 56.7 46.2 47.2 50.4 53.9 42.8 43.7 46.7 49.9
S/T 0.85 0.80 0.65 0.49 0.89 0.83 0.68 0.51 0.91 0.85 0.69 0.52 0.94 0.88 0.72 0.54 0.97 0.91 0.74 0.56 0.98 0.92 0.75 0.56
∆T 25 24 21 17 26 25 21 17 26 25 21 17 26 25 22 17 25 24 21 17 24 23 20 16
1621 kW 3.79 3.87 3.99 4.12 4.08 4.17 4.30 4.44 4.34 4.43 4.57 4.72 4.56 4.66 4.81 4.97 4.75 4.85 5.01 5.18 4.91 5.02 5.19 5.36
Amps 15.9 16.3 16.8 17.3 17.1 17.4 18.0 18.6 18.4 18.8 19.4 20.0 19.5 20.0 20.6 21.3 20.7 21.1 21.8 22.5 21.8 22.3 23.0 23.8
Hi PR 228 245 259 270 256 275 291 303 291 313 330 345 331 356 376 393 373 401 423 442 412 443 468 488
Lo PR 105 112 122 130 111 118 129 137 115 123 134 143 121 129 141 150 127 135 147 157 131 140 152 162
Expanded Cooling Data — GPH1360H41* (cont.)

MBh 59.3 60.5 63.3 67.6 58.0 59.1 61.9 66.0 56.6 57.7 60.4 64.4 55.2 56.3 58.9 62.9 52.4 53.5 56.0 59.7 48.6 49.5 51.9 55.3
S/T 0.97 0.94 0.85 0.69 1.00 0.97 0.88 0.71 1.00 1.00 0.90 0.73 1.00 1.00 0.93 0.76 1.00 1.00 0.97 0.78 1.00 1.00 0.97 0.79
∆T 26 25 24 21 26 25 24 21 25 25 24 21 24 25 24 21 23 24 24 21 21 22 22 19

www.goodmanmfg.com
2079 kW 3.95 4.03 4.16 4.29 4.25 4.34 4.48 4.63 4.52 4.62 4.77 4.92 4.75 4.86 5.02 5.18 4.95 5.06 5.23 5.41 5.13 5.24 5.42 5.60
Amps 16.6 16.9 17.4 18.0 17.8 18.2 18.7 19.3 19.2 19.6 20.2 20.9 20.4 20.8 21.5 22.2 21.6 22.0 22.7 23.5 22.7 23.3 24.0 24.8
Hi PR 240 258 272 284 269 289 306 319 306 329 348 362 348 375 396 413 392 422 445 464 433 466 492 513
Lo PR 110 117 128 137 117 124 135 144 121 129 141 150 127 135 148 158 133 142 155 165 138 147 160 171
MBh 57.6 58.7 61.5 65.6 56.3 57.4 60.1 64.1 54.9 56.0 58.6 62.6 53.6 54.6 57.2 61.0 50.9 51.9 54.4 58.0 47.2 48.1 50.3 53.7
S/T 0.93 0.90 0.81 0.66 0.96 0.93 0.84 0.68 0.99 0.95 0.86 0.70 1.00 0.98 0.89 0.72 1.00 1.00 0.92 0.75 1.00 1.00 0.93 0.75
∆T 27 26 25 21 27 26 25 22 27 27 25 22 27 27 25 22 25 26 25 22 23 24 23 20
85 1850 kW 3.92 4.00 4.12 4.26 4.22 4.31 4.44 4.59 4.48 4.58 4.73 4.88 4.71 4.82 4.98 5.14 4.91 5.02 5.19 5.36 5.08 5.20 5.37 5.55
Amps 16.5 16.8 17.3 17.9 17.6 18.0 18.6 19.2 19.0 19.4 20.0 20.7 20.2 20.6 21.3 22.0 21.4 21.9 22.5 23.3 22.5 23.1 23.8 24.6
Hi PR 237 255 270 281 266 286 303 316 303 326 344 359 345 371 392 409 388 417 441 460 429 461 487 508
Lo PR 109 116 127 135 116 123 134 143 120 128 139 148 126 134 146 156 132 141 153 163 137 145 159 169
MBh 53.2 54.2 56.8 60.6 51.9 52.9 55.4 59.2 50.7 51.7 54.1 57.7 49.5 50.4 52.8 56.3 47.0 47.9 50.2 53.5 43.5 44.4 46.5 49.6
S/T 0.90 0.86 0.78 0.63 0.93 0.90 0.81 0.66 0.95 0.92 0.83 0.67 0.98 0.95 0.86 0.69 1.00 0.98 0.89 0.72 1.00 0.99 0.90 0.73
∆T 27 27 25 22 27 27 25 22 27 27 25 22 28 27 26 22 27 27 25 22 25 25 24 20
1621 kW 3.82 3.90 4.02 4.15 4.11 4.20 4.34 4.48 4.37 4.47 4.61 4.76 4.60 4.70 4.85 5.01 4.79 4.90 5.06 5.23 4.96 5.07 5.23 5.41
Amps 16.1 16.4 16.9 17.4 17.2 17.6 18.1 18.7 18.5 19.0 19.5 20.2 19.7 20.1 20.7 21.5 20.8 21.3 22.0 22.7 22.0 22.5 23.2 24.0
Hi PR 230 248 262 273 258 278 293 306 294 316 334 348 335 360 380 396 376 405 428 446 416 447 472 493
Lo PR 106 113 123 131 112 119 130 139 116 124 135 144 122 130 142 151 128 136 149 159 133 141 154 164
IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions kW = Total system power

31
High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan)
Product Specifications
Product Specifications

Expanded Heating Data


GPH1324H21*
Outdoor Ambient Temperature
65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10
MBh 30.2 28.6 26.9 25.1 24.0 23.3 21.6 19.9 16.9 15.6 14.4 13.6 13.1 11.8 10.4 9.1 7.8 6.4
∆T 32.9 31.1 29.3 27.4 26.1 25.3 23.5 21.7 18.5 17.0 15.7 14.8 14.3 12.8 11.3 9.9 8.4 6.9
kW 2.23 2.18 2.14 2.10 2.07 2.05 2.01 1.96 2.02 1.97 1.93 1.90 1.88 1.83 1.79 1.74 1.69 1.65
Amps 11.1 10.4 9.8 9.3 9.0 8.9 8.4 8.0 7.8 7.5 7.2 7.0 6.9 6.7 6.3 6.0 5.6 5.2
COP 3.96 3.83 3.68 3.51 3.39 3.32 3.15 2.97 2.45 2.32 2.19 2.09 2.04 1.87 1.70 1.53 1.34 1.13
EER 13.5 13.1 12.6 12.0 11.6 11.3 10.8 10.1 8.4 7.9 7.5 7.2 7.0 6.4 5.8 5.2 4.6 3.9
Hi PR 238 228 220 210 205 201 193 186 178 170 163 159 156 150 145 139 134 129
Lo PR 78 73 68 62 59 57 52 46 42 37 33 31 30 25 22 18 16 12

GPH1324H41**
Outdoor Ambient Temperature
65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10
MBh 27.7 26.2 24.6 23.0 22.0 21.3 19.8 18.3 17.4 16.1 14.8 14.0 13.5 12.1 10.7 9.4 8.0 6.5
∆T 29.3 27.7 26.1 24.4 23.3 22.6 21.0 19.3 18.5 17.0 15.7 14.8 14.3 12.8 11.3 9.9 8.4 6.9
kW 2.01 1.97 1.94 1.90 1.88 1.86 1.82 1.78 1.82 1.78 1.74 1.72 1.70 1.66 1.62 1.58 1.54 1.50
Amps 9.6 9.0 8.5 8.1 7.8 7.7 7.3 7.0 6.7 6.5 6.2 6.1 6.0 5.8 5.5 5.2 4.9 4.5
COP 4.02 3.88 3.73 3.55 3.43 3.36 3.18 3.00 2.81 2.65 2.50 2.39 2.32 2.13 1.94 1.73 1.52 1.28
EER 13.7 13.3 12.7 12.1 11.7 11.5 10.9 10.2 9.6 9.1 8.5 8.2 7.9 7.3 6.6 5.9 5.2 4.4
Hi PR 366 351 337 323 315 309 297 285 273 261 251 245 240 231 222 213 205 198
Lo PR 132 122 114 105 99 95 88 78 70 63 55 51 50 42 36 31 27 21

GPH1330H21**
Outdoor Ambient Temperature
65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10
MBh 34.4 32.6 30.7 28.7 27.4 26.6 24.7 22.7 19.7 18.2 16.7 15.8 15.2 13.7 12.1 10.6 9.0 7.4
∆T 30.4 28.8 27.1 25.3 24.2 23.4 21.7 20.1 17.4 16.0 14.8 13.9 13.4 12.0 10.7 9.3 7.9 6.5
kW 2.70 2.65 2.59 2.54 2.51 2.49 2.44 2.38 2.34 2.28 2.23 2.20 2.18 2.12 2.07 2.02 1.97 1.91
Amps 13.1 12.2 11.5 10.9 10.6 10.4 9.9 9.5 9.2 8.8 8.5 8.3 8.2 7.9 7.5 7.1 6.7 6.2
COP 3.73 3.60 3.46 3.30 3.19 3.12 2.96 2.79 2.46 2.33 2.19 2.10 2.04 1.88 1.71 1.53 1.34 1.13
EER 12.7 12.3 11.8 11.3 10.9 10.7 10.1 9.5 8.4 8.0 7.5 7.2 7.0 6.4 5.8 5.2 4.6 3.9
Hi PR 244 234 225 215 210 206 198 190 182 174 167 163 160 154 148 142 137 132
Lo PR 80 74 69 63 60 58 53 47 43 38 33 31 30 25 22 18 16 13

GPH1330H41**
Outdoor Ambient Temperature
65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10
MBh 33.9 32.1 30.2 28.3 27.0 26.2 24.3 22.4 19.8 18.2 16.8 15.9 15.3 13.7 12.1 10.6 9.0 7.4
∆T 29.9 28.3 26.7 24.9 23.8 23.1 21.4 19.8 17.4 16.1 14.8 14.0 13.5 12.1 10.7 9.3 8.0 6.5
kW 2.43 2.39 2.34 2.29 2.27 2.25 2.20 2.16 2.50 2.44 2.38 2.35 2.33 2.27 2.21 2.16 2.10 2.04
Amps 12.1 11.3 10.7 10.1 9.8 9.6 9.2 8.8 8.5 8.1 7.8 7.7 7.6 7.2 6.9 6.5 6.1 5.7
COP 4.08 3.94 3.78 3.61 3.49 3.41 3.23 3.04 2.32 2.19 2.06 1.98 1.92 1.77 1.61 1.44 1.26 1.06
EER 14.0 13.5 12.9 12.3 11.9 11.6 11.0 10.4 7.9 7.5 7.0 6.7 6.6 6.0 5.5 4.9 4.3 3.6
Hi PR 384 368 354 338 331 324 312 299 287 274 263 256 252 242 233 223 215 208
Lo PR 132 122 115 105 99 96 88 78 71 63 55 52 50 42 36 31 27 21
Above data is for nominal CFM and 70º indoor dry bulb. Instantaneous capacity listed. Amps = Unit amps (comp.+ evaporator motor + condenser fan motor)
High pressure is measured at the liquid line access fitting. kW = Total system power Low pressure is measured at the compressor suction access fitting.

32 www.goodmanmfg.com SS-GPH13H
Product Specifications

Expanded Heating Data (cont.)


GPH1336H21**
Outdoor Ambient Temperature
65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10
MBh 42.2 40.0 37.6 35.2 33.6 32.6 30.2 27.9 22.4 20.7 19.1 18.0 17.3 15.6 13.8 12.0 10.3 8.4
∆T 31.3 29.6 27.9 26.1 24.9 24.1 22.4 20.7 16.6 15.3 14.1 13.3 12.8 11.5 10.2 8.9 7.6 6.2
kW 3.12 3.06 3.00 2.93 2.90 2.87 2.82 2.76 2.66 2.60 2.54 2.51 2.49 2.43 2.37 2.31 2.25 2.19
Amps 12.2 11.4 10.8 10.3 10.0 9.8 9.4 9.0 8.7 8.4 8.1 8.0 7.9 7.6 7.2 6.9 6.5 6.1
COP 3.97 3.83 3.68 3.51 3.39 3.31 3.14 2.96 2.47 2.33 2.19 2.10 2.04 1.88 1.70 1.52 1.33 1.12
EER 13.6 13.1 12.6 12.0 11.6 11.3 10.7 10.1 8.4 8.0 7.5 7.2 7.0 6.4 5.8 5.2 4.6 3.8
Hi PR 238 228 220 210 205 201 193 186 178 170 163 159 156 150 145 139 134 129
Lo PR 81 75 70 65 61 59 54 48 43 39 34 32 31 26 22 19 16 13

GPH1336H41**
Outdoor Ambient Temperature
65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10
MBh 42.2 40.0 37.6 35.2 33.6 32.6 30.2 27.9 22.4 20.7 19.1 18.0 17.3 15.6 13.8 12.0 10.3 8.4
∆T 32.6 30.9 29.0 27.1 25.9 25.1 23.3 21.5 17.3 16.0 14.7 13.9 13.4 12.0 10.6 9.3 7.9 6.5
kW 2.99 2.94 2.88 2.82 2.79 2.77 2.72 2.66 2.76 2.70 2.64 2.61 2.58 2.52 2.47 2.41 2.35 2.29
Amps 14.8 13.9 13.1 12.5 12.1 11.9 11.3 10.8 10.5 10.1 9.7 9.5 9.4 9.0 8.6 8.2 7.7 7.1
COP 4.13 3.99 3.82 3.64 3.52 3.44 3.26 3.07 2.38 2.24 2.11 2.02 1.96 1.80 1.64 1.46 1.28 1.07
EER 14.1 13.6 13.1 12.5 12.0 11.8 11.1 10.5 8.1 7.7 7.2 6.9 6.7 6.2 5.6 5.0 4.4 3.7
Hi PR 368 353 339 324 317 311 299 287 274 262 252 246 241 232 223 214 206 199
Lo PR 134 125 117 107 101 97 90 80 72 64 57 53 51 43 37 31 27 21

GPH1342H21*
Outdoor Ambient Temperature
65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10
MBh 47.8 45.2 42.6 39.8 38.0 36.8 34.2 31.5 27.2 25.1 23.1 21.8 21.0 18.8 16.7 14.6 12.4 10.2
∆T 30.5 28.9 27.2 25.4 24.3 23.5 21.8 20.1 17.3 16.0 14.7 13.9 13.4 12.0 10.7 9.3 7.9 6.5
kW 3.32 3.26 3.20 3.14 3.10 3.07 3.01 2.95 2.94 2.88 2.82 2.78 2.76 2.69 2.63 2.57 2.50 2.44
Amps 12.9 12.1 11.5 10.9 10.6 10.4 10.0 9.6 9.3 9.0 8.6 8.5 8.4 8.1 7.7 7.4 7.0 6.5
COP 4.21 4.06 3.89 3.71 3.59 3.51 3.32 3.13 2.70 2.55 2.40 2.29 2.23 2.05 1.86 1.66 1.45 1.22
EER 14.4 13.9 13.3 12.7 12.3 12.0 11.3 10.7 9.2 8.7 8.2 7.8 7.6 7.0 6.4 5.7 5.0 4.2
Hi PR 232 223 214 205 200 196 189 181 173 166 159 155 152 147 141 135 130 126
Lo PR 80 74 69 63 60 58 53 47 43 38 33 31 30 25 22 18 16 13

GPH1342H41**
Outdoor Ambient Temperature
65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10
MBh 47.8 45.2 42.6 39.8 38.0 36.8 34.2 31.5 27.4 25.3 23.3 22.0 21.2 19.0 16.9 14.7 12.5 10.3
∆T 31.4 29.7 27.9 26.1 25.0 24.2 22.5 20.7 18.0 16.6 15.3 14.4 13.9 12.5 11.1 9.7 8.2 6.7
kW 3.27 3.21 3.15 3.09 3.06 3.04 2.98 2.92 3.03 2.97 2.90 2.87 2.84 2.78 2.71 2.65 2.59 2.53
Amps 11.9 11.2 10.7 10.2 9.9 9.8 9.4 9.0 8.8 8.5 8.2 8.1 8.0 7.8 7.4 7.1 6.8 6.4
COP 4.27 4.12 3.95 3.76 3.63 3.55 3.36 3.16 2.65 2.50 2.35 2.25 2.18 2.00 1.82 1.62 1.42 1.19
EER 14.6 14.1 13.5 12.9 12.4 12.1 11.5 10.8 9.0 8.5 8.0 7.7 7.5 6.8 6.2 5.5 4.8 4.1
Hi PR 355 341 327 313 306 300 288 277 265 253 243 237 233 224 216 207 199 192
Lo PR 130 121 113 104 98 94 87 77 70 62 55 51 49 41 36 30 26 21
Above data is for nominal CFM and 70º indoor dry bulb. Instantaneous capacity listed. Amps = Unit amps (comp.+ evaporator motor + condenser fan motor)
High pressure is measured at the liquid line access fitting. kW = Total system power Low pressure is measured at the compressor suction access fitting.

SS-GPH13H www.goodmanmfg.com 33
Product Specifications

Expanded Heating Data (cont.)


GPH1348H21*
Outdoor Ambient Temperature
65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10
MBh 56.6 53.6 50.4 47.1 45.0 43.6 40.5 37.4 28.9 26.7 24.6 23.2 22.3 20.0 17.8 15.5 13.2 10.8
∆T 31.7 30.1 28.3 26.4 25.3 24.5 22.7 21.0 16.2 15.0 13.8 13.0 12.5 11.2 10.0 8.7 7.4 6.1
kW 4.27 4.19 4.12 4.04 4.00 3.97 3.90 3.82 3.58 3.51 3.44 3.40 3.37 3.30 3.23 3.16 3.09 3.02
Amps 21.4 20.0 18.8 17.9 17.3 17.0 16.2 15.5 14.9 14.4 13.8 13.5 13.4 12.8 12.1 11.5 10.9 10.0
COP 3.88 3.74 3.58 3.41 3.29 3.22 3.04 2.86 2.36 2.22 2.09 2.00 1.94 1.78 1.61 1.43 1.25 1.05
EER 13.2 12.8 12.2 11.7 11.3 11.0 10.4 9.8 8.1 7.6 7.1 6.8 6.6 6.1 5.5 4.9 4.3 3.6
Hi PR 244 234 225 215 210 206 198 190 182 174 167 163 160 154 148 142 137 132
Lo PR 77 71 67 61 58 56 51 46 41 37 32 30 29 25 21 18 16 12

GPH1348H41**
Outdoor Ambient Temperature
65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10
MBh 55.9 53.0 49.8 46.6 44.5 43.1 40.1 36.9 32.4 29.9 27.5 26.0 25.0 22.5 19.9 17.4 14.8 12.1
∆T 32.4 30.6 28.8 27.0 25.8 25.0 23.2 21.4 18.7 17.3 15.9 15.0 14.5 13.0 11.5 10.1 8.6 7.0
kW 3.72 3.65 3.58 3.52 3.48 3.45 3.38 3.32 3.40 3.33 3.26 3.22 3.19 3.12 3.05 2.98 2.90 2.83
Amps 19.1 17.9 16.9 16.1 15.6 15.4 14.6 14.0 13.5 13.1 12.6 12.3 12.2 11.7 11.1 10.6 10.0 9.3
COP 4.40 4.24 4.07 3.88 3.74 3.66 3.46 3.26 2.79 2.63 2.47 2.37 2.30 2.11 1.91 1.71 1.49 1.25
EER 15.0 14.5 13.9 13.2 12.8 12.5 11.8 11.1 9.5 9.0 8.4 8.1 7.9 7.2 6.5 5.8 5.1 4.3
Hi PR 366 351 337 323 315 309 297 285 273 261 250 244 240 231 222 213 205 198
Lo PR 130 121 113 104 98 94 87 77 70 62 55 51 49 41 36 30 26 21

GPH1360H21*
Outdoor Ambient Temperature
65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10
MBh 68.4 64.7 60.9 57.0 54.4 52.7 49.0 45.2 36.6 33.8 31.1 29.4 28.3 25.4 22.5 19.6 16.8 13.7
∆T 33.3 31.5 29.7 27.8 26.5 25.7 23.9 22.0 17.9 16.5 15.2 14.3 13.8 12.4 11.0 9.6 8.2 6.7
kW 5.04 4.94 4.84 4.75 4.69 4.65 4.55 4.46 4.35 4.25 4.16 4.10 4.06 3.96 3.87 3.77 3.67 3.58
Amps 22.1 20.7 19.5 18.6 18.0 17.7 16.9 16.2 15.6 15.1 14.5 14.2 14.1 13.5 12.8 12.2 11.6 10.7
COP 3.97 3.83 3.68 3.51 3.39 3.32 3.15 2.97 2.46 2.33 2.19 2.10 2.04 1.88 1.70 1.52 1.33 1.12
EER 13.6 13.1 12.6 12.0 11.6 11.3 10.8 10.1 8.4 8.0 7.5 7.2 7.0 6.4 5.8 5.2 4.6 3.8
Hi PR 238 228 220 210 205 201 193 186 178 170 163 159 156 150 145 139 134 129
Lo PR 74 69 65 59 56 54 50 44 40 36 31 29 28 24 20 17 15 12

GPH1360H41**
Outdoor Ambient Temperature
65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10
MBh 68.5 64.9 61.0 57.1 54.5 52.8 49.1 45.2 39.9 36.8 33.9 32.0 30.8 27.6 24.5 21.4 18.2 14.9
∆T 34.3 32.5 30.6 28.6 27.3 26.4 24.5 22.6 20.0 18.4 17.0 16.0 15.4 13.8 12.3 10.7 9.1 7.5
kW 5.30 5.19 5.09 4.98 4.92 4.87 4.77 4.67 41.89 40.71 39.57 38.88 38.42 37.24 36.10 34.96 33.78 32.64
Amps 22.8 21.3 20.1 19.0 18.4 18.0 17.1 16.3 15.7 15.1 14.5 14.2 14.0 13.4 12.6 12.0 11.2 10.3
COP 3.78 3.65 3.51 3.35 3.24 3.17 3.01 2.84 0.28 0.26 0.25 0.24 0.23 0.22 0.20 0.18 0.16 0.13
EER 12.9 12.5 12.0 11.5 11.1 10.8 10.3 9.7 1.0 0.9 0.9 0.8 0.8 0.7 0.7 0.6 0.5 0.5
Hi PR 370 354 341 326 318 312 300 288 276 263 253 247 242 233 224 215 207 200
Lo PR 125 116 108 99 94 90 83 74 67 60 52 49 47 40 34 29 25 20
Above data is for nominal CFM and 70º indoor dry bulb. Instantaneous capacity listed. Amps = Unit amps (comp.+ evaporator motor + condenser fan motor)
High pressure is measured at the liquid line access fitting. kW = Total system power Low pressure is measured at the compressor suction access fitting.

34 www.goodmanmfg.com SS-GPH13H
Product Specifications

Heat Kit Electrical Data (Blower Only, Heat Mode)


Circuit #1 Circuit #2 Actual kW /
Model and Heat Kit Usage
MCA¹ MOD² MCA¹ MOD² BTU@ 240V
GPH1324H21A* 1.5 / 1.5 -- -- -- --
HKR-05*, HKR-05C* 24 / 27 30 / 30 -- -- 4.75 / 16,200
HKR-08*, HKR-08C* 33 / 38 40 / 40 -- -- 7 / 23,800
HKR-10*, HKR-10C* 45 / 51 60 / 60 -- -- 9.5 / 32,400
GPH1324H41** 1.5 / 1.5 -- -- -- --
HKR-05*, HKR-05C* 24 / 27 30 / 30 -- -- 4.75 / 16,200
HKR-08*, HKR-08C* 33 / 38 40 / 40 -- -- 7 / 23,800
HKR-10*, HKR-10C* 45 / 51 60 / 60 -- -- 9.5 / 32,400
GPH1330H21A* 2.4 / 2.4 -- -- -- --
HKR-05*, HKR-05C* 24 / 27 30 / 30 -- -- 4.75 / 16,200
HKR-08*, HKR-08C* 34 / 39 40 / 40 -- -- 7 / 23,800
HKR-10*, HKR-10C* 45 / 52 60 / 60 -- -- 9.5 / 32,400
HKR-15*, HKR-15C* 45 / 52 60 / 60 22 / 25 30 / 30 14.25 / 48,600
GPH1330H41** 2.4 / 2.4 -- -- -- --
HKR-05*, HKR-05C* 24 / 27 30 / 30 -- -- 4.75 / 16,200
HKR-08*, HKR-08C* 34 / 39 40 / 40 -- -- 7 / 23,800
HKR-10*, HKR-10C* 45 / 52 60 / 60 -- -- 9.5 / 32,400
HKR-15*, HKR-15C* 45 / 52 60 / 60 22 / 25 30 / 30 14.25 / 48,600
GPH1336H21A* 2.4 / 2.4 -- -- -- --
HKR-05*, HKR-05C* 24 / 27 30 / 30 -- -- 4.75 / 16,200
HKR-08*, HKR-08C* 34 / 39 40 / 40 -- -- 7 / 23,800
HKR-10*, HKR-10C* 45 / 52 60 / 60 -- -- 9.5 / 32,400
HKR-15*, HKR-15C* 45 / 52 60 / 60 22 / 25 30 / 30 14.25 / 48,600
GPH1336H41** 2.4 / 2.4 -- -- -- --
HKR-05*, HKR-05C* 24 / 27 30 / 30 -- -- 4.75 / 16,200
HKR-08*, HKR-08C* 34 / 39 40 / 40 -- -- 7 / 23,800
HKR-10*, HKR-10C* 45 / 52 60 / 60 -- -- 9.5 / 32,400
HKR-15*, HKR-15C* 45 / 52 60 / 60 22 / 25 30 / 30 14.25 / 48,600
¹ Minimum Circuit Ampacity @ 208 / 240V
² Maximum Overcurrent Protection (amps) @ 208 / 240V
* Indicates revision letter that may or may not be designated

SS-GPH13H www.goodmanmfg.com 35
Product Specifications

Heat Kit Electrical Data (Blower Only, Heat Mode)


Circuit #1 Circuit #2 Actual kW /
Model & Heat Kit Usage
MCA¹ MOD² MCA¹ MOD² BTU@ 240V
GPH1342H21A* 3.9 / 3.9 -- -- -- --
HKR-05*, HKR-05C* 25 / 27 30 / 30 -- -- 4.75 / 16,200
HKR-08*, HKR-08C* 34 / 39 40 / 40 -- -- 7 / 23,800
HKR-10*, HKR-10C* 46 / 52 60 / 60 -- -- 9.5 / 32,400
HKR-15*, HKR-15C* 46 / 52 60 / 60 22 / 25 30 / 30 14.25 / 48,600
HKR-20*,HKR-20C* 46 / 52 60 / 60 43 / 49 60 / 60 19.5 / 66,500
GPH1342H41** 3.9 / 3.9 -- -- -- --
HKR-05*, HKR-05C* 25 / 27 30 / 30 -- -- 4.75 / 16,200
HKR-08*, HKR-08C* 34 / 39 40 / 40 -- -- 7 / 23,800
HKR-10*, HKR-10C* 46 / 52 60 / 60 -- -- 9.5 / 32,400
HKR-15*, HKR-15C* 46 / 52 60 / 60 22 / 25 30 / 30 14.25 / 48,600
HKR-20*,HKR-20C* 46 / 52 60 / 60 43 / 49 60 / 60 19.5 / 66,500
GPH1348H21A* 3.9 / 3.9 -- -- -- --
HKR-05*, HKR-05C* 25 / 28 30 / 30 -- -- 4.75 / 16,200
HKR-08*, HKR-08C* 34 / 40 40 / 40 -- -- 7 / 23,800
HKR-10*, HKR-10C* 46 / 53 60 / 60 -- -- 9.5 / 32,400
HKR-15*, HKR-15C* 46 / 52 60 / 60 22 / 25 30 / 30 14.25 / 48,600
HKR-20*,HKR-20C* 46 / 52 60 / 60 43 / 49 60 / 60 19.5 / 66,500
GPH1348H41** 3.9 / 3.9 -- -- -- --
HKR-05*, HKR-05C* 25 / 28 30 / 30 -- -- 4.75 / 16,200
HKR-08*, HKR-08C* 34 / 40 40 / 40 -- -- 7 / 23,800
HKR-10*, HKR-10C* 46 / 53 60 / 60 -- -- 9.5 / 32,400
HKR-15*, HKR-15C* 46 / 52 60 / 60 22 / 25 30 / 30 14.25 / 48,600
HKR-20*,HKR-20C* 46 / 52 60 / 60 43 / 49 60 / 60 19.5 / 66,500
GPH1360H21A* 6.0 / 6.0 -- -- -- --
HKR-05*, HKR-05C* 26 / 30 30 / 30 -- -- 4.75 / 16,200
HKR-08*, HKR-08C* 36 / 40 40 / 40 -- -- 7 / 23,800
HKR-10*, HKR-10C* 48 / 54 60 / 60 -- -- 9.5 / 32,400
HKR-15*, HKR-15C* 48 / 54 60 / 60 22 / 25 30 / 30 14.25 / 48,600
HKR-20*,HKR-20C* 48 / 54 60 / 60 43 / 49 60 / 60 19.5 / 66,500
GPH1360H41** 6.0 / 6.0 -- -- -- --
HKR-05*, HKR-05C* 26 / 30 30 / 30 -- -- 4.75 / 16,200
HKR-08*, HKR-08C* 36 / 40 40 / 40 -- -- 7 / 23,800
HKR-10*, HKR-10C* 48 / 54 60 / 60 -- -- 9.5 / 32,400
HKR-15*, HKR-15C* 48 / 54 60 / 60 22 / 25 30 / 30 14.25 / 48,600
HKR-20*,HKR-20C* 48 / 54 60 / 60 43 / 49 60 / 60 19.5 / 66,500
¹ Minimum Circuit Ampacity @ 208 / 240V
² Maximum Overcurrent Protection (amps) @ 208 / 240V
* Indicates revision letter that may or may not be designated

36 www.goodmanmfg.com SS-GPH13H
Product Specifications

Dimensions

 






   


 





 





Dimensions Chasis Size


Model
W” D” H” Small Med. Large
GPH1324H21A* 66½ 34 30 X
GPH1324H41** 66½ 34 30 X
GPH1330H21A* 66½ 34 30 X
GPH1330H21AD 66½ 34 30 X
GPH1330H41** 66½ 34 30 X
GPH1336H21A/B 66½ 34 35 X
GPH1336H21AC/D 66½ 34 35 X
GPH1336H21AE 66½ 34 35 X
GPH1336H41** 66½ 34 35 X
GPH1342H21AD 66½ 34 35 X
GPH1342H21AE 66½ 34 35 X
GPH1342H41** 66½ 34 35 X
GPH1348H21A* 66½ 34 38⅔ X
GPH1348H41** 66½ 34 38⅔ X
GPH1360H21A* 66½ 34 38⅔ X
GPH1360H41** 66½ 34 38⅔ X

SS-GPH13H www.goodmanmfg.com 37
Product Specifications

Wiring Diagram — GPH1324-48H21A*

PU
BK BK
NOTE #4
RD 1 2 3 PU PU
208 240
BL
RD C BK
GR 2
TR
G EBTDR BL RD T2 L2 0
BL 24V
R NO BK RD 8
K1
C SEE NOTE #6 -
XFMR-R BL
RD BK 2


XFMR-C COM BL T1 L1
K1
RD BK 4
C
NOTE #2 NC RD 0
SPEED YL RD /
M1 M2

High Voltage: Disconnect all power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.
UP YL RD 1
BK BK
GND /
PU BL 6
OR
0
DC OR RD
C
Y YL
PU RD
O
BK O BK YL BR
LVDR BUSHING LVJB
RD W2 WH T
WH H
YL Y
R RD BL RD R E
BK PLF GR G R
HVDR R RD 3 6 9 WH W1 M
YL H C F
DFT OR O O
2 5 8 BR BR W2 S
DF2 DF1 RD RD RCCF T
BL C
SA A
1 4 7 T
RD
PU BR ++
PU PU BK
(IF USED)
SEE NOTE #5 RD
RD RD RD (TRANS240V) RD
BK PU (M1) RD LOW BK
YL CONTROL
BL PU BK BOX
(COM) BK HIGH BR S C R
PU EM RD LPS
BR 3 SPEED DFT BR EM
BKBK BR 2 SPEED CM RD CH
OPTIONAL COMP
NOTE #3
FC
FC
RVC

L1 L2
SUPPLY VOLTAGE
208-240/1/60
CH SEE NOTE #3 COMPONENT LEGEND FACTORY WIRING
C CONTACTOR LINE VOLTAGE
T2 C LOW VOLTAGE
R CH CRACKCASE HEATER
C T1 CM CONDENSER MOTOR OPTINAL HIGH
C COMP C DF1 DF2 COMP COMPRESSOR VOLTAGE
S H RCCF
HVDR DC DEFROST CONTROL FIELD WIRING
PLF F DFT DEFROST THERMOSTAT HIGH VOLTAGE

WARNING
S.A. NOTE #5 CM EBTDR ELECTRONIC BLOWER TIME DELAY RELAY LOW VOLTAGE
EM EVAPORATOR MOTOR
3 2 FC FAN CAPACITOR
GND EQUPIMENT GROUND
NC

M1 NOTE#2 HVDR HIGH VOLTAGE DEFROST RELAY WIRE CODE


EBTDR EBTDR
M2
LPS LOW PRESSURE SWITCH BK BLACK


COM NO LVDR LOW VOLTAGE DEFROST RELAY BL BLUE
EM LVJB LOW VOLTAGE JUNCTION BOX BR BROWN
FC PLF FEMALE PLUG / CONNECTOR GR GREEN
RVC REVERSING VAVLE COIL OR ORANGE
208-240 RCCF RUN CAPACITOR FOR PU PURPLE
NOTE #4 COMPRESSOR AND FAN RD RED
Wiring is subject to change. Always
refer to the wiring diagram or the
2 SA START ASSIST WH WHITE unit for the most up-to-date wiring.
3 1
TR TRANSFORMER YL YELLOW
TR

24V
EBTDR NOTES:
R G C
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT
LEAST 105°C) USE COPPER CONDUCTOR ONLY.
R DFT 2. TO CHANGE EVAPORATOR MOTOR SPEED REPLACE LEAD ON EBTDR "COM" WITH LEAD
DFT C
DC ON EBTDR "M1" OR "M2"
Y 3. CRANKCASE HEAT NOT SUPPLIED ON ALL UNITS.
R W2 4. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES FROM TERMINAL 3
LVDR RVC TERMINAL 2 ON TRANSFORMER.
5. START ASSIST FACTOR EQUIPED WHEN REQUIRED
O 6. USE COPPER CONDUCTORS ONLY
O ++ USE N.E.C. CLASS 2 WIRE
4
P C
L 5 LPS
SEE UNIT RATING PLATE FOR TYPE AND SIZE
F
OF OVER CURRENT PROTECTION
6

R W2 O W1 Y G C

THERMOSTAT
208-240/1/60 0140G00034P

38 www.goodmanmfg.com SS-GPH13H
Product Specifications

Wiring Diagram — GPH1324-48H21AB/AC

PU
BK BK
NOTE #4
RD 1 2 3 PU PU
BL
RD C 208 240 BK
GR 2
TR
G EBTDR BL RD T2 L2 0
24V
BL NO BK RD 8
R K1
1 3 C SEE NOTE #6
BL -
XFMR-R
BK 2


XFMR-C COM BL T1 L1
K1
RD RD 2
BK 4
C PU 4
NOTE #2 NC BR
OR 0
SPEED YL /
M1 M2 RD

High Voltage: Disconnect all power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.
UP BK BK YL OR 1
/
BL GND
OR 6
0
DC OR
C RD

Y YL
PU RD
O BK
BK O BK YL BR
LVDR PU BUSHING LVJB
W2 WH T
RD WH
YL Y H
R RD BL RD R E
BK GR G R
PLF
HVDR R RD 3 6 9 WH W1 M
YL H C F
OR O O
DFT
2 5 8 BR W2 S
DF2 DF1 BR
RD RD RCCF T
BL C
SA A
1 4 7
RD T
PU BR ++
(IF USED) PU BK
SEE NOTE #5

RD RD (TRANS240V) RD
BK PU (M1) RD LOW BK
RD YL CONTROL
BL PU BK BOX
BK
(COM) BK HIGH BR S C R
PU EM LPS
BR EM OR
BR 3 SPEED DFT
BK BR 2 SPEED CM OR
OPTIONAL
COMP CH
NOTE #3
FC
FC
RVC

L1 L2
SUPPLY VOLTAGE
208-240/1/60
CH SEE NOTE #3 COMPONENT LEGEND FACTORY WIRING
BR BLOWER INTERLOCK RELAY LINE VOLTAGE
T2 C C CONTACTOR LOW VOLTAGE
C R OPTINAL HIGH
T1 CH CRACKCASE HEATER
C COMP CM CONDENSER MOTOR VOLTAGE
C DF1 DF2
S H RCCF
HVDR COMP COMPRESSOR
DC DEFROST CONTROL FIELD WIRING
F

WARNING
DFT DEFROST THERMOSTAT HIGH VOLTAGE
S.A. NOTE #5 CM EBTD ELECTRONIC BLOWER TIME DELAY LOW VOLTAGE
R RELAY
BR EM EVAPORATOR MOTOR
1 P
L FC FAN CAPACITOR
1 3 3 F GND EQUPIMENT GROUND
HVDR HIGH VOLTAGE DEFROST RELAY


2 4 LPS LOW PRESSURE SWITCH
LVDR LOW VOLTAGE DEFROST RELAY WIRE CODE
LVJB LOW VOLTAGE JUNCTION BOX BK BLACK
C

M1 BL BLUE
N

EBTDR
NOTE#2 EBTDR PLF FEMALE PLUG / CONNECTOR
M2 RVC REVERSING VAVLE COIL BR BROWN
COM NO GR GREEN
EM RCCF RUN CAPACITOR FOR
Wiring is subject to change. Always
refer to the wiring diagram or the
unit for the most up-to-date wiring.
COMPRESSOR AND FAN OR ORANGE
FC SA START ASSIST PU PURPLE
208-240 TR TRANSFORMER RD RED
NOTE #4 WH WHITE
2 YL YELLOW
3 1
TR

24V
EBTDR
R G C NOTES:

1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS


DFT ORIGINAL (AT
R DFT C LEAST 105°C) USE COPPER CONDUCTOR ONLY.
DC
Y 2. TO CHANGE EVAPORATOR MOTOR SPEED REPLACE LEAD ON EBTDR
R W2 "COM" WITH LEAD
ON EBTDR "M1" OR "M2"
LVDR RVC 3. CRANKCASE HEAT NOT SUPPLIED ON ALL UNITS.
O 4. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES
O FROM TERMINAL 3
TERMINAL 2 ON TRANSFORMER.
P 4 5. START ASSIST FACTOR EQUIPED WHEN REQUIRED
L C 6. USE COPPER CONDUCTORS ONLY
F 5 ++ USE N.E.C. CLASS 2 WIRE
6 SEE UNIT RATING PLATE FOR TYPE AND SIZE
R W2 O W1 Y G C OF OVER CURRENT PROTECTION

THERMOSTAT 208-240/1/60 0140G00365 REV. B

SS-GPH13H www.goodmanmfg.com 39
Product Specifications

Wiring Diagram — GPH1324-48H41**

PU
BK BK
NOTE #4
RD 1 2 3 PU PU
BL
RD C 208 240 BK
GR 2
TR
G EBTDR BL RD T2 L2 0
24V
BL NO BK RD 8
R K1
1 3 C SEE NOTE #6
BL -
XFMR-R
XFMR-C COM BK T1 L1 2
K1 BL RD RD 2
BK 4
C PU 4
BR 0


NOTE #2 NC YL OR
SPEED M1 M2 RD /
UP BK BK YL OR 1
/

High Voltage: Disconnect all power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.
BL GND
OR 6
0
DC OR
C RD

Y YL
PU RD
O BK
BK O BK YL BR
LVDR PU BUSHING LVJB
W2 WH T
RD WH
YL Y H
R RD BL RD R E
BK GR G R
PLF
HVDR R RD 3 6 9 WH W1 M
YL H C F
OR O O
DFT
2 5 8 BR W2 S
DF2 DF1 BR
RD RD RCCF T
BL C
SA A
1 4 7
RD T
PU BR ++
(IF USED) PU BK
SEE NOTE #5

RD RD (TRANS240V) RD CONTROL
BK PU (M1) RD LOW BK BOX
RD YL
BL PU BK
BK
(COM) BK HIGH BR S C R
PU EM LPS HPS
BR EM OR
BR 3 SPEED DFT
BK BR 2 SPEED CM OR
OPTIONAL
COMP CH
NOTE #3
FC
FC
RVC

L1 L2
SUPPLY VOLTAGE
208-240/1/60
CH SEE NOTE #3 COMPONENT LEGEND FACTORY WIRING
BR BLOWER INTERLOCK RELAY LINE VOLTAGE
T2 C C CONTACTOR LOW VOLTAGE
C R OPTINAL HIGH
T1 CH CRACKCASE HEATER
C COMP CM CONDENSER MOTOR VOLTAGE
C DF1 DF2
S H RCCF
HVDR COMP COMPRESSOR

WARNING
DC DEFROST CONTROL FIELD WIRING
F HIGH VOLTAGE
DFT DEFROST THERMOSTAT
S.A. NOTE #5 CM EBTD ELECTRONIC BLOWER TIME DELAY LOW VOLTAGE
R RELAY
BR EM EVAPORATOR MOTOR
1 P
L FC FAN CAPACITOR

1 3 3 F GND EQUPIMENT GROUND
HVDR HIGH VOLTAGE DEFROST RELAY
2 4 LPS LOW PRESSURE SWITCH
LVDR LOW VOLTAGE DEFROST RELAY WIRE CODE
LVJB LOW VOLTAGE JUNCTION BOX BK BLACK
NC

M1 NOTE#2 BL BLUE
EBTDR EBTDR PLF FEMALE PLUG / CONNECTOR
Wiring is subject to change. Always
refer to the wiring diagram or the
unit for the most up-to-date wiring.

M2 RVC REVERSING VAVLE COIL BR BROWN


COM NO GR GREEN
EM RCCF RUN CAPACITOR FOR
COMPRESSOR AND FAN OR ORANGE
FC SA START ASSIST PU PURPLE
208-240 TR TRANSFORMER RD RED
NOTE #4 WH WHITE
2 YL YELLOW
3 1 HPS HIGH PRESSURE SWITCH
TR

24V
EBTDR
R G C NOTES:

1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS


DFT ORIGINAL (AT
R DFT C LEAST 105°C) USE COPPER CONDUCTOR ONLY.
DC
Y 2. TO CHANGE EVAPORATOR MOTOR SPEED REPLACE LEAD ON EBTDR
R W2 "COM" WITH LEAD
ON EBTDR "M1" OR "M2"
LVDR RVC 3. CRANKCASE HEAT NOT SUPPLIED ON ALL UNITS.
O 4. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES
O FROM TERMINAL 3
TERMINAL 2 ON TRANSFORMER.
P 4 5. START ASSIST FACTORY EQUIPED WHEN REQUIRED
L C 6. USE COPPER CONDUCTORS ONLY
F 5 ++ USE N.E.C. CLASS 2 WIRE
6 HPS LPS
SEE UNIT RATING PLATE FOR TYPE AND SIZE
R W2 O W1 Y G C OF OVER CURRENT PROTECTION

THERMOSTAT 208-240/1/60 0140G00874 REV. A

40 www.goodmanmfg.com SS-GPH13H
Product Specifications

Wiring Diagram — GPH1360H21*A*A

PU
BK
RD RD NOTE #3
1 2 3 PU PU
2 IBR 1 208 240
BL
C BK
TR 2
BL RD T2 L2 0
24V
RD 8
4 3 BL C SEE NOTE 5 -


RD BK T1 L1 2
GR WH 4
BK
0

High Voltage: Disconnect all power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.
BL YL /
GR BL RD
WH BK BK 1
BK YL /
GR GND 6
RD 0
DC
C RD OR
OR
Y YL
PU RD
O
LVJB
YL BR
O BK
LVDR
W2 WH WH T
YL Y H
R RD GR E
BL PLF RD R
BL BK GR G R
HVDR R RD 3 6 9 WH W1 M
WH H C F O
DFT OR O
2 5 8 BR BR W2 S
DF2 DF1 RD RCCF T
GR BL C
YL RD A
1 4 7 T
RD
PU BR ++
SA (IF USED) PU BK
SEE NOTE 4

RD
BK CONTROL
RD RD PU BK YL BOX
GR BR
C L G N S C R
1 2 3
DFT CM
EM BK BK LPS
COMP
SEE NOTE 2 RVC

L1 L2 COMPONENT LEGEND FACTORY WIRING


SUPPLY VOLTAGE C CONTACTOR LINE VOLTAGE
208-240/1/60 LOW VOLTAGE
CM CONDENSER MOTOR
COMP COMPRESSOR OPTINAL HIGH
T2 C DC DEFROST CONTROL VOLTAGE
C T1 R DFT DEFROST THERMOSTAT FIELD WIRING
C COMP C DF1 DF2
EM EVAPORATOR MOTOR HIGH VOLTAGE
S H RCCF HVDR GND EQUIPMENT GROUND LOW VOLTAGE
(HIGH VOLT)
F HVDR HIGH VOLTAGE DEFROST RELAY

WARNING
S.A. CM IBR INDOOR BLOWER RELAY
NOTE #4
LPS LOW PRESSURE SWITCH
LVDR LOW VOLTAGE DEFROST RELAY WIRE CODE
IF USED LVJB LOW VOLTAGE JUNCTION BOX BK BLACK
PLF FEMALE PLUG / CONNECTOR BL BLUE
NOTE #2
RVC REVERSING VAVLE COIL BR BROWN
L


N EM RCCF RUN CAPACITOR FOR GR GREEN
3 COMPRESSOR AND FAN OR ORANGE
1 G SA START ASSIST PU PURPLE
2
TR TRANSFORMER RD RED
208-240 WH WHITE
Wiring is subject to change. Always
refer to the wiring diagram or the
unit for the most up-to-date wiring.
NOTE #3
3
2
1
YL YELLOW
TR

24V NOTES:
DFT C
R
DC 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT
DFT
Y LEAST 105°C) USE COPPER CONDUCTOR ONLY.
R W2 2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE LEAD FROM EM "1" TO "2" OR "3".
RVC
O TERMINAL "3" IS HIGHEST SPEED.
LVDR 3. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES FROM TERMINAL 3
2
TO
3
O TERMINAL 2 ON TRANSFORMER.
1 EM C 4. START ASSIST FACTOR EQUIPED WHEN REQUIRED
4 SEE NOTE #2 5. USE COPPER CONDUCTORS ONLY
5 2 4 ++ USE N.E.C. CLASS 2 WIRE
6 IBR
1 3
PLF LPS
C

SEE UNIT RATING PLATE FOR TYPE AND SIZE


OF OVER CURRENT PROTECTION

R W2 O W1 Y G C

THERMOSTAT

208-240/1/60 0140G00081P

SS-GPH13H www.goodmanmfg.com 41
Product Specifications

Wiring Diagram — GPH1360H21AB/AC


NOTE #3
PU
BK
PU PU
1 2 3 BL
C 208 240
BK 2
TR
BL RD T2 L2 0
24V
RD 8
BL C SEE NOTE 5 -


BL 2
BK T1 L1
BK 4
0

High Voltage: Disconnect all power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.
/
BL YL 1
BK RD YL /
GR GR GND
60
DC
C RD OR RD
OR
Y YL
PU RD
O
RD LVJB
YL BR
O BK
LVDR WH
W2 WH WH T
H
GR YL Y
R RD BL RD R E
YL PLF
BL BK GR G R
HVDR R 3 6 9 WH W1 M
H C F
GR DFT OR O O
RD S
DF1 2 5 8 BR BR W2
DF2 RD RCCF T
WH BL C
YL RD A
1 4 7
RD T
PU BR ++
SA (IF USED) PU BK
SEE NOTE 4

RD
BK CONTROL
RD RD PU BR BK YL BOX
GR
C L G N S C R
1 2 3 4 5
DFT CM
BK BK LPS
EM COMP
RVC
SEE NOTE 2

L1 L2 COMPONENT LEGEND FACTORY WIRING


SUPPLY VOLTAGE C CONTACTOR LINE VOLTAGE
208-240/1/60 CM CONDENSER MOTOR LOW VOLTAGE
COMP COMPRESSOR OPTINAL HIGH
DC DEFROST CONTROL VOLTAGE
T2 C
R DFT DEFROST THERMOSTAT
C T1 FIELD WIRING
EM EVAPORATOR MOTOR
C COMP C DF1 DF2 GND EQUIPMENT GROUND HIGH VOLTAGE
S H RCCF HVDR HVDR HIGH VOLTAGE DEFROST RELAY LOW VOLTAGE
(HIGH VOLT)
F LPS LOW PRESSURE SWITCH

WARNING
S.A. NOTE #4 CM LVDR LOW VOLTAGE DEFROST RELAY
LVJB LOW VOLTAGE JUNCTION BOX WIRE CODE
PLF FEMALE PLUG / CONNECTOR BK BLACK
IF USED RVC REVERSING VAVLE COIL BL BLUE
RCCF RUN CAPACITOR FOR BR BROWN
NOTE #2
COMPRESSOR AND FAN GR GREEN
L OR ORANGE


N EM SA START ASSIST
3 TR TRANSFORMER PU PURPLE
RD RED
1 G WH WHITE
2
YL YELLOW
208-240
Wiring is subject to change. Always
refer to the wiring diagram or the
unit for the most up-to-date wiring.
NOTE #3 2
3 1

TR

24V NOTES:
DFT C
R
DC 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS
DFT
Y ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY.
R W2 2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW
RVC LEADS FROM EM"2" AND "3" TO "4" AND "5". IF BOTH LEADS ARE
O
LVDR
ENERGIZED, THE HIGHER SPEED SETTING IS USED.
3. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES FROM
TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
O 2 3 4. START ASSIST FACTOR EQUIPED WHEN REQUIRED
1 EM C
5. USE COPPER CONDUCTORS ONLY
4 ++ USE N.E.C. CLASS 2 WIRE
SEE NOTE #2
5
6
PLF LPS
C

SEE UNIT RATING PLATE FOR TYPE AND SIZE


OF OVER CURRENT PROTECTION

R W2 O W1 Y G C

THERMOSTAT

208-240/1/60 0140G00408

42 www.goodmanmfg.com SS-GPH13H
Product Specifications

Wiring Diagram — GPH1360H41**


NOTE #3
PU
BK
PU PU
1 2 3 BL
C 208 240
BK 2
TR
BL RD T2 L2 0
24V
RD 8
BL C SEE NOTE 5 -
BL 2
BK T1 L1
BK 4


0
/
BL YL 1
RD

High Voltage: Disconnect all power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.
BK YL /
GR GR GND
60
DC
C RD OR RD
OR
Y YL
PU RD
O
RD LVJB
YL BR
O BK
LVDR WH
W2 WH WH T
H
GR YL Y
R RD BL RD R E
YL PLF
BL BK GR G R
HVDR R 3 6 9 WH W1 M
H C F
GR DFT OR O O
RD S
DF1 2 5 8 BR BR W2
DF2 RD RCCF T
WH BL C
YL RD A
1 4 7
RD T
PU BR ++
SA (IF USED) PU BK
SEE NOTE 4

RD CONTROL
BK BOX
RD RD PU BR BK YL
GR
C L G N S C R
1 2 3 4 5
DFT CM HPS
BK BK LPS
EM COMP
RVC
SEE NOTE 2

L1 L2 COMPONENT LEGEND FACTORY WIRING


SUPPLY VOLTAGE C CONTACTOR LINE VOLTAGE
208-240/1/60 CM CONDENSER MOTOR LOW VOLTAGE
COMP COMPRESSOR OPTINAL HIGH
DC DEFROST CONTROL VOLTAGE
T2 C
R DFT DEFROST THERMOSTAT
C T1 FIELD WIRING
EM EVAPORATOR MOTOR
C COMP C DF1 DF2 GND EQUIPMENT GROUND HIGH VOLTAGE
S H RCCF HVDR HVDR HIGH VOLTAGE DEFROST RELAY LOW VOLTAGE
(HIGH VOLT)

WARNING
F LPS LOW PRESSURE SWITCH
S.A. NOTE #4 CM LVDR LOW VOLTAGE DEFROST RELAY
LVJB LOW VOLTAGE JUNCTION BOX WIRE CODE
PLF FEMALE PLUG / CONNECTOR BK BLACK
IF USED RVC REVERSING VAVLE COIL BL BLUE
RCCF RUN CAPACITOR FOR BR BROWN
NOTE #2 GR GREEN
N EM
3
L
SA
TR
COMPRESSOR AND FAN
START ASSIST
TRANSFORMER
OR ORANGE
PU PURPLE

RD RED
1 G HPS HIGH PRESSURE SWITCH WH WHITE
2
YL YELLOW
Wiring is subject to change. Always
refer to the wiring diagram or the
unit for the most up-to-date wiring.

208-240
NOTE #3 2
3 1

TR

24V NOTES:
DFT C
R
DC 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS
DFT
Y ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY.
R W2 2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW
RVC LEADS FROM EM"2" AND "3" TO "4" AND "5". IF BOTH LEADS ARE
O
LVDR
ENERGIZED, THE HIGHER SPEED SETTING IS USED.
3. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES FROM
TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
O 2 3 4. START ASSIST FACTORY EQUIPED WHEN REQUIRED
1 EM C
5. USE COPPER CONDUCTORS ONLY
4 ++ USE N.E.C. CLASS 2 WIRE
SEE NOTE #2
5
6
PLF C
HPS LPS
SEE UNIT RATING PLATE FOR TYPE AND SIZE
OF OVER CURRENT PROTECTION

R W2 O W1 Y G C

THERMOSTAT

208-240/1/60 0140G00872 REV. A

SS-GPH13H www.goodmanmfg.com 43
Product Specifications

Notes

Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice
or without incurring obligations. © 2010 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA.

44 www.goodmanmfg.com SS-GPH13H

Das könnte Ihnen auch gefallen