Carrier 40RR packaged air handlers provide an efficient source of conditioned air in factories, shops, offices or restaurants. Coupled with appropriate condensing units, the 40RR Series produces nominal cooling capacities of 88,000 to 638,000 Btuh.
Carrier 40RR packaged air handlers provide an efficient source of conditioned air in factories, shops, offices or restaurants. Coupled with appropriate condensing units, the 40RR Series produces nominal cooling capacities of 88,000 to 638,000 Btuh.
Copyright:
Attribution Non-Commercial (BY-NC)
Verfügbare Formate
Als PDF, TXT herunterladen oder online auf Scribd lesen
Carrier 40RR packaged air handlers provide an efficient source of conditioned air in factories, shops, offices or restaurants. Coupled with appropriate condensing units, the 40RR Series produces nominal cooling capacities of 88,000 to 638,000 Btuh.
Copyright:
Attribution Non-Commercial (BY-NC)
Verfügbare Formate
Als PDF, TXT herunterladen oder online auf Scribd lesen
The 40RR Weathermaker® packaged air handlers provide an efficient source of conditioned air in factories, shops, offices or restaurants. Coupled with appropriate condensing units, the 40RR Series produces nominal cooling capacities of 88,000 to 638,000 Btuh. Accessory steam or hot water heating coils produce heating capacities in the range of 118,000 to 1,585,000 Btuh.
Slim proportions (less than 3 ft wide) allow these units to be floor mounted or ceiling-suspended. Modular construction (014 size and larger) permits the fan section to be mounted in front of, on top of, or behind the coil section. In addition, the fan section can be rotated for front, top, or rear air discharge ... horizontal or vertical, as you require. 40RR008 thru 024 units are used with a plenum or ductwork; 028 thru 054 units are connected directly to duct systems.
H-R
2
--
. ",
•
Carrier quality construction features assure an attractive and durable unit Removable casing panels provide easy access for servicing Heavy-gage, galvanized steel is enamel-coated for corrosion resistance Units are good-looking and may be installed in the conditioned space where required.
Belt-drive, centrifugal fans move air quietly - may be used with ductwork or for free blow (direct discharge) into the conditioned space. Resilient motor mounts help absorb vibration.
Insulated casing minimizes condensation and reduces sound levels.
Adaptable to heat pump service
The 40RR012 thru 054 units can be used for heat pump service with the addition of an accessory piping package. Nominal cooling range is 121,000 to 518,000 Btuh; heating range is 118,000 to 556,000 Btuh.
The Carrier line of 40RR packaged air handling units offers versatile performance for a business that demands optimum efficiency and reliability.
•
•
Modular construction allows interchangeable fan section arrangements .
•
I~i!~
, ,
::j': ' : : ,: " ,
" '
,::,:",,',, ,
.;,:,':, :::,.,:
=:;:,:::::::, , '
?:::, ' \\:::::::'
y? ' , , , '
\-.._/ ,
.~.
'::::::,:
J/:'
IT )
NOTE
Units 40RR008 and 012 are shipped assembled for straight-thru horizontal discharge Units 40RR014 thru 054 are shipped in the vertical arrangement with vertical discharge
•
Accessories
Overhead suspension package contains hanger straps for 40RR008 and 40RR012. Package for larger size units contains a bottom panel to cover the exposed base of the unit. (Larger units do not require hanger straps.)
Discharge plenum has a grille with movable vanes for horizontal or vertical airflow adjustment (40RR008 thru 024).
Horizontal discharge package is required when a vertical unit arrangement is used with a horizontal fan discharge (40RR014 thru 40RR054).
Return air grille covers return air opening when a finished appearance is required (40RR008 thru 024).
Heating coils are available in two types: two-row hot water or one-row steam distributing (all 40RR)
Evaporator defrost thermostat prevents evaporator freeze-up. Package contains thermostat with enclosure, wiring and hardware.
•
':<,";
J:'
" '
::: '
Multi-unit control package for use with multiple heat pump condensing units operating in conjunction with 40RR indoor unit. Package consists of two 24-volt relays in an enclosure.
Remote control transformer relay package contains fan and liquid line solenoid relays, and terminal board in an enclosure (40RR012 thru 054).
--+ Heat pump piping package is used to pipe indoor unit for heat pump service (40RR012 thru 054).
--+ Subbase for use on 40RR008, 012 units as a floor stand or return air inlet. Subbase is required on 40RR014 thru 054 units in order to make condensate drain connection when unit is floor mounted. Subbase is standard on 40RR028 and 034.
Thermostat assemblies with or without automatic changeover operate on 24 volts.
Fan motors and drives are factory installed on units 40RR008 thru 024. Accessory drive packages are available
1. Determine the cooling load and temperature and quantity of air entering the evaporator.
Given:
Grand Total Heat 200,000 Btuh
Sensible Heat 130,000 Btuh
Air Temp Ent Indoor Coil. . . . . . . .. 80 F db, 67 F wb
Air Qty Ent Indoor Coil. 6000 cfm
Ductwork Static Pressure Loss 0.8 in. wg
2. Determine unit selection and coil refrigerant temperature.
Enter Cooling Capacities table for 6000 cfm. Select a 40RR016 unit which has a total capacity of 228,000 and 195,000 Btuh at 40 and 45 F coil refrigerant temperature respectively. By interpolation, coil refrigerant temperature of 44.2 F is needed to give a total capacity of 200,000 Btuh. Sensible capacity is 151,000 Btuh. Cooling load is satisfied.
Heating - 40RR
1. Determine heating load and temperature of air entering the indoor coil.
Given:
Load 375,000 Btuh
Entering Air Temperature 70 F
Two-row Hot Water Coils with entering water temperature of 200 F.
2. Find the heating capacity .
Enter Heating Ratings table for the 40RR016 unit at 6000 cfm. A two-row hot water coil delivers 428,000 Btuh (based on 60 F entering air temperature). Since existing entering air temperature is 70 F, enter the Btu Constants table for hot water coils at 200 F entering water temperature and this 70 F entering air. Read a constant of .90.
428,000 x .90 = 385,200 Btuh
Fan - 40RR
1. Determine fan speed and brake horsepower.
From the table titled Pressure Loss of Unit Components, read a loss of .06 in. wg for a two-row hot-water heating coil.
External static pressure = .80 + .06
= .86 in. wg
Enter 40RR016 Fan Performance table at 6000 cfm and .86 in. wg. Interpolate and read fan speed of 795 rpm and 2.41 bhp. Checking the table on page 5, the factoryinstalled motor for a 40RR016 is a 2 hp. Since the bhp required is 2.41, a 3 hp motor should be used. From the tables on page 6, a 3 hp motor and drive can be selected.
To select an outdoor unit for this 40RR016 indoor section, refer to the Combination Ratings sheets for Carrier condensing units.
NOTE: Multiply capacity given in Heating Ratings table by the Btu constant for conditions at which unit is actually operating Correct leaving air temperature using formulas in Note 3 under Heating Ratings table
1 Direct interpolation is permissible Do not extrapolate 2 Evaporator fan heat not deducted from ratings
3 Ratings based on approximately 12 F superheat leaving coil 4 Dashes indicate coil loading limits are exceeded
5 Formulas:
Leaving db
. se nsible heat capacity (Btuh)
= entering db - 1 09 x elm
Leaving wb = wet-bulb temperature corresponding to enthalpy of air leaving coil(hlwb)
h - h totalcapacity(Btuh)
Iwb - ewb - 45 x cfm
where hewb = enthalpy of air entering coil
PLENUM AIR DISTRIBUTION
CEILING MIN HT (tt)
UNIT NOM CFM
17 15 14
40RR008 3000
40RR012 4000
20 17 16
40RR014 40RR016 40RR024
6000
24 21 19
40RR024 8000
VVS - Vertical Vane Setting in Degrees
*If length of blow or outlet velocity is excessive on 016 or 024 units. two field-supplied plenum side outlet grilles may be used Refer to 40RR Application Data for details
LDB - Leaving Air Dry-Bulb Temp (F) PD - Pressure Drop (ft water)
*Based on 2 psig steam, 60 F entering air temperature
[Based on 200 F entering water, 20 F water temperature drop,
60 F entering air temperature
NOTES
1 Maximum operating limits for heating coils, 200psig and 400 F 2 Maximum allowable leaving air temperature is 140 F
3 capacity (Btuh)
Leaving db = ent db (F) + 1 09 x cfm
capacity (Btuh)
G pm = -=-:::-::---_:____:_:__--;--:-;:::-
500 x water temp drop (F)
40RR008, 012, 014 and 016 units are rated in accordance with ARI Standard 21 0-75 when used in combination with components specified by the manufacturer
For combination ratings, see 38 Series Combination Rating Sheets
*Motors are designed for satisfactory operation at ± 10% of nominal voltages shown Voltages should not exceed the limits shown in the "Voltage Limits" column
[Motors must be field wired for 460 volts in accordance with directions on nameplate of motor
NOTE Fan motors are field supplied on 40RR028 thru 054 units
•
•
ELECTRIC HEATER DATA
11
Furnish and install __ direct-expansion fan-coil unit(s) in the location(s) shown on the plans.
Total cooling capacity shall be __ Btuh or more and
total room sensible capacity shall be Btuh or more at
a coil refrigerant temperature of __ F under the following conditions:
Air entering unit __ F db, __ F wb
Air leaving unit __ F db, __ F wb
Cooling coils shall be of nonferrous construction with mechanically bonded smooth plate fins with a total face area of not less than __ square feet. All tube joints shall be brazed with phoscopper or silver alloy. (When more than one coil is used, provisions should exist for increased latent heat removal at partial loads.)
Evaporator fan section shall have forward-curved blades, double-inlet fans mounted on a common shaft. Fans shall be statically and dynamically balanced and shall run on
cfm with __ in. wg external static pressure operating at __ rpm, __ bhp.
Casing shall be made of galvanized steel, bonderized and finished with baked enamel.
Unit construction shall be such that horizontal or vertical discharge may be achieved by relocating the fan section.
Number One Air Conditioning Maker
_Divisionol
.. Carrier Corporation
Provisions shall exist for suspending the unit from an over- •. head support.
Filters shall be standard size and not less than __ in. thick. They shall have a face area of __ sq ft or more. High velocity permanent (low velocity throwaway) filters shall be used and shall be protected from the cooling coil condensate.
Dimensions: __ in. width; in. depth; in.
height.
Accessories, as indicated, shall be field installed as shown on the plans:
Steam Heating Coil(s) shall be located as shown on the drawing(s). Supply and return connections shall be made at the same end of the coil. Entering air temperature shall be __ F with __ cfm. Coil capacity shall be __ Btuh with __ psig steam. Heating coils shall be the steam distributing type.
Hot Water Heating Coil(s) shall be located as shown on the drawing(s). Supply and return connections shall be made at the same end of the coil. Entering air temperature shall be __ F with cfm. Coil capacity shall be ___ Btuh with __ gpm of __ F entering water.
Electric Resistance Heaters shall have a capacity of __ Btuh.
•
o
Carrier Parkway _ Syracuse NY 13221
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.