Beruflich Dokumente
Kultur Dokumente
•Required Modules
•Optional Modules
Objectives
• 3 HU modules
• For stand alone and cabinet
installations
• 133 x 447 x 560 [mm], (H x W x D)
• Weight 10 … 20 kg
(+ 6 kg for casing and covers)
• 2 HU modules
• For stand alone and cabinet
installations
• 89 x 447 x 560 [mm], (H x W x D)
560 mm
• Weight 10 kg
447 mm (+ 5 kg for casing and covers)
• 4 HU module (RTC only)
• Only for cabinet installations
• 171 x 447 x 415 [mm], (H x W x D)
• Weight 28.5 kg
• In cabinet installations max module
depth is 422 mm
Nokia Flexi EDGE System Module (ESMA, 3HU)
1xBus
HU = 44.4 mm
0-2xWideband combiners
Nokia Flexi EDGE Dual Duplexer Module
(ERxA, 1HU)
• Dual duplexer (DDU) module together with Dual TRX create a logical Sector module
• Min 1 DDU per sector is needed
• DDU is attached to DTRX module
• DDU provides
• duplex functionality to combine TX and RX signals to same antenna feeder
• multicoupling
• 2 antenna connections (for 1 or 2 sectors)
• 2 TX inputs and 4+4 RX outputs (4 RX from antenna 1 and 4 RX from antenna 2)
• DDU contains
• 2 duplex filter
• 2 Low Noise Amplifiers (LNAs) with high/low gain support for RX signal
• 2 Bias-Ts with VSWR measurement functionality
• TRX loop is controlled through the DDU
• Common TRX loop for all TRXs in same sector
• Loop can be performed from either TX to any of 8 RX outputs (only 1 TX and 1 RX can be
simultaneously tested)
Ant 1 Ant 2
TX 1 RX for 4xRX 1 4xRX 2 RX for TX 2
external external HU = 44.4 mm
BTS BTS
Flexi EDGE Wideband Combiner
DP TXout
There are three variants:
• EWGA 850/900 MHz Bands
• EWDA 1800 MHz Band TXa TXb
• EWPA 1900 MHz Band
Specifications:
• TXa or TXb to TXout <3.5dBm
• Max power (CW) 48dBm (63 Watts)
Tx
TxB
Out
50
Ohms
mode. 50
Ohms 50
Ohms
Dual duplexer
module
3HU
Dual TRX
module
Nokia Flexi EDGE System Extension Module
(ESEA, 3HU)
• System extension module is required for large BTS configurations
(System module for 1-6 DTRX, System extension module for 7-12 DTRX)
• System extension module is always required for RTC configurations
• All TRXs must be connected to same system module for BB hopping
• The functionalities of System extension module:
• Power distribution to additional modules (i.e. DTRX 7-12). Power
distribution part has six 48V outputs
• Providing 12 Ethernet and synchronization connections to DTRX (DTRX 1-
12) and 1 connection to System module
PDU (power
distribution
PDU (power Ethernet to
unit) 48V intake
distribution unit) System module
6x48V to other
modules
12x Ethernet
to DTRX
ESMA compared to ESEA
6
6
2
DTRX 3
Network Ethernet
4
5
DTRX 4 X
Ethernet Switch
ESM Interface
X
Ethernet Switch
6 (GE, RS-485)
1..6
ECxA 1-3
ESMA on its own controls TRX’s… ..When ESEA is used, the ESEA controls the TRX’
- The ESMA now is used only for the ECxA’s (RTC
Nokia Flexi EDGE RTC Module, cavity
combining (ECxA, 4HU)
• Optional RTC module for ETSI frequency bands combines max 6 TRX/antenna
• Min 1 RTC per sector is needed
• RTC provides:
• Combining of up to 6 TX signals to same antenna feeder
• Duplex functionality to combine TX and RX signals to same antenna feeder
• Multicoupling
• 2 antenna connections (for 1 or 2 sectors)
• 6 TX inputs and 3+3 RX outputs (3 RX from antenna 1 and 3 RX from antenna 2)
• RTC module contains:
• 6 tunable cavity combiner
• 2 Low Noise Amplifiers (LNAs) for RX signal
• 2 duplex filter
• 2 Bias-Ts with VSWR measurement functionality
• TRX loop is controlled through the RTC
• Loop can be performed from 6 TX to any of 6 RX outputs (only 1 TX and 1 RX can be simultaneously tested)
• DTRX connected to system module via single Gigabit Ethernet interface
• Power feed from system module via single cable
HU = 44.4 mm
6xTX
Nokia Flexi EDGE BTS powering: distributed
power supply
• System module distributes power to
other modules DTRX module
• All modules generate own internal DTRX module
voltages
48VDC
System module
• BTS powering may be supplied from:
• Nokia Flexi Power AC/DC module DTRX module
(with or without battery) providing
48VDC input to the power RTC module
distribution
• Nokia Flexi Power DC/DC module
(24/48VDC)
• Integrated long term battery back-
up (MIBBU)
• Standard Site support cabinet
Nokia Flexi Power Module (FPMA, 3HU)
• Power module provides the casing and cable connectors for 4 power sub-modules
• input / output terminals, output DC and alarm cables
• Power AC-DC sub-module (FPAA)
• 230V AC 48V DC converter
• 0…4 FPAA per Power module; 1kW power each
• includes AC-filters
• Battery sub-module (FPBA)
• gives minute-level back-up when AC mains are down
• 0…4 FPBA per Power module (except – how can they be charged?)
48DCV output
24 V DC input
Summary of units
Main modules of Nokia Flexi EDGE BTS
HU = 44.4 mm
Optional modules and sub-modules (1)
• Up to ?? Ah
Common modules with Nokia Flexi WCDMA
BTS