Sie sind auf Seite 1von 12
Service Manual BioVue Centrifuge Manual System Rev.October.14.92 Dr. Molter GmbH Germany BioYue Centrifuge Rev HAY.4.92 10 ul. Servicesanual CONTENTS Contents Specifications Theory of operation Operating Instructions Circuit Description Circuit Diagram 1 of 9 Circuit diagran 2 of 3 Circuit Diagran 3 of 3 Placeplan Reconmended Spare Part List EC-tronic Pots Pagel Page Page Page Page Page Page Page Page Page Page Page 10 i BioVue Cantrifuge Rev MAY. 4.1992 Dimensions - Weight Power : - Speed Speed Indicator Timer Indicator: Cassetto Capacity: Page 2 pee © Height/Width/Dopth 240/320/355 mm 12.5 kg 100-240 V,50/60 Hz single phase 25 W Phase I 794 RPM +-2% 55 xg Phase II 1510 RPM +-2% 199 x g 4 Digits 3 Digits (min.10 x sec,sec) 12 Cassettes \NOTE:Repair and maintenance of the instrument are only to be done by the manufacturer or authorized persons. INOTE:The power line for the instrument must be connected to protective earth. Page 3 Theory of operation Speed and time preset (794 RPM 55 xg 2 Min.. 1510 RPM 199 xg 3 Min. ) Unit is switched on by power switch on the right sido Unit is activated by pressing "START" button.Lid has to be opened first to load centrifuge olse start function is inhibited. Lid must be closed for operation. A lid switch prevents operation when lid is open. After cycle completed lid can be opened until a timeout occurs. to avoid overheating of lid solenoid. To open after timeout press "STOP" again to release solenoid. Cycle can be interrupted by pressing "STOP" button Display will start with 5 00(Min.). When cycle is started the countdown time to 0 00(Min.) will be displayed. When "START" button is pressed and pressure maintained during run cycle, the RPM's will be displayed. RPM is monitored every 5 seconds. Time is displayed again after "START" button is released Ramp up alarm is installed for first and second speed. If ramp uf alarm occurs instrument stops and alarm signal continues until "STOP" button is pressed. An imbalance detection stops instrument if unbalanced after 5 to 10 seconds. Page 4 Connect instrument to mains. Switch instrument on. Instrument will beep 3x and display 5 00. Open lid. INOTE:Make sure that lid is opened to mechanical stop.in order to avoid any hazard of injury. B. Operation Load centrifuge with cassettes. Close lid. Press “START" button. To select speed display during operation, press “START” button 5. When cycle is finished. instrument will beep 3x. Lid can be opened. To avoid heatup of lid solenoid lock will be closed after software time out. In this case you can open lid by pressing "STOP" button. 6 Lift rotor's center to lock cassette holders in place( for unloading or loading cassettes ). INOTE:Safety directions for handling the reagent cassettes have to be adhered to File: BIOSM1.txt Page 1 of 1 Revision May 12th, 1992 uit Description BioVue Centrifuge Control PCB The Centrifuge functions are controlled by a processor PCB. The processor circuit consists of a Z 80 Microprocessor with 2 K RAM (61 16), 8 K ROM (27 G4), a reset and voltage control circuit (77 05), a Clock circuit (CLK 4M) and an input/output device (82 55). The’ input/output device controls the 4 x 7 segment display and the functions: motor on - off, the high - low relais K1, the lid solenoid, the brake and the beeper. Inputs are the lid switch, the vibration switch and the reed signal from the motor controler. Motor Controler pc Board The pots Pl and P2 on the control PC board are used for the adjustment of low speed (794 RPM adjusted to 804 with two cassettes) and high speed (1510 adjusted to 1520 with two cassettes). Pot P2 on the motor control PC board is used as a current limiting pot and is adjusted to max CW. Pot P3 is for basic RPM adjustment (see speed adjustment). Pl on the motor control PCB is not used with this application. Power Supply ‘The power supply Z2PS 45 supplies regulated + 5 Volt output for logic devices and + 12 volt for motor power. Speed Adjustment Procedure - insert speed adjust UV PROM - connect instrument to power turn power on insert two cassettes adjust pot P2 on motor controler board fully clockwise adjust both pots on control PC board fully clockwise press Start button and adjust speed with pot P3 on motor controler PC board to 1550 - 1650 RPM adjust RPM on control PC board for 803 RPM for phase 1 and 1520 RPM for phase 2 switch instrument off - change UV PROM - varify speed adjustment with Biovue UV PROM ' 12.05.92 vs/ir sat iii PI P2 PS ne Current Limit Basic Speed Haj. adj. to max PA fololo res Tvane a roenun | roo |e | ==, 1 Aaa ie (AA ak — i PAQ'zg0loteialts ZS"O1'9? abnytuyusg snnora BioVue Centrifuge Recoamended Spare Parts List 606381 Rotor kpl 606372 Kessel kpl. 606373 Deckel kpi 606374 PCB BioVue kpl 608034 © Motor ECA 27.11 608015 Ectronic 24/5 bearb 608035 Netzteil ZPS45 602509 Kabel Netz EUR 608036 © Kabel Netz US 608143 Sicherung 1A If 607515 Hetzschalter . Filter 608048 UY Pron BioVue 606375 Decke1-Schn. ~Versch1u8 607130 Deckel Drucktaster 608044 Folientastatur 608054 —Hylstop M3 608069 UV-PROM Speedadjust 608070 Rotorverkzeug 608045 Vibrationsschalter File: BIOSN2.txt Page 1 of 1 Rev. Dec 18,92 Rotor assy Basin assy Lid assy. PCB Biovue Motor ECA 27.11 Ectronic 24/5 wi. Pover Supply ZPS 45 Power Cord EUR Pover Cord US Fuse 1 AM Pover Switch vith Filter UV Pron BioVue Lid Lock Lid Switch Frontpanel vith Membrane Switches Hylstop M3 UV-PROM Speedadjust Allen Wrench for Rotor Vibration switch

Das könnte Ihnen auch gefallen