Sie sind auf Seite 1von 45

DO IT YOURSELF

METHOD
STATEMENT
By

TECH-DRY (INDIA) PVT. LTD.,


No.769, 1st Cross, 1st Stage, Indiranagar, Bangalore 560
038
Phone: 25255294 / 25255406 / 25289159
E-mail – techdry@airtelmail.in
Items for Waterproofing
1. Retaining Walls & Floor.
2. Podium Slab with Gutter (Hard & Soft
Scopes)
3. * Toilets / Balconies (4” Sunken)
* Utilities / Servants Toilet (9” Sunken)
1. * Flat Terrace.
* Curved Roofs.
5. OHT’s
6. Sumps
7. Expansion Joints
8. Detailing for
* Construction Joints
* Bore Packing
* Beam & Block work joints.
* Slab Cracks.
EVOLUTION OF TREATMENT
METHODOLOGY
1. Cleaning
2. Defect Removal
3. Permeability reduction
4. Bonding Layers
5. Slope making with water resistant concrete
6. Permeability reduction
7. Water repellency
8. Protective coatings
Retaining Wall
Retaining Floor

Protekta Flex Joint


Protekta Base
Injection / Grouting
Protekta Plastofelt
Protekta Grip
Protekta Abrasion
Construction
resist Joint

RCC

Footing
Protekta Abrasion resist
Protekta
Base PCC
Protekta SB
Soling Soling
Retaining Wall & Floor
Retaining Wall:
Treatment on + ve side:
• Brush / spray application of impregnation product called
Protekta Base which fills the fine pores with crystalline
silicate growth, coverage 2 Sq. M / Ltr.
• Brush application of one coat of Protekta Flexjoint on the
construction joint only. Thickness of application will be
approx. 0.5 mm.
• Plastering at the Starter Joint, Construction joints and any
other defects like honeycombs, tie-rod locations etc with
polymer sealant 500 modified mortar.
• Brush coat of Protekta Plastofelt primer
• Brush coat of Protekta Plastofelt to provide a very strong
coating to resist hydrostatic pressure.
• Brush coat of Protekta Top Seal Coat as hard layer. After the
application of this layer, plastering is not required.
Treatment on –ve side:
·    Injections/Grouting at starter joint & construction joints with
Protekta Grip / Protekta Hydro Grout.
Floor
Treatment on + ve side:
• After PCC has been laid, grout Protekta SB mixed
with Protekta SS and catalyst at regular intervals of
every 1 M center to center. This grout material has
property of expanding when it comes in contact with
water. It forms a water impervious layer and
prevents travel of water to the top of PCC.
• Spray of Protekta Base on PCC surface towards
porosity reduction.
• Application of a slurry prepared with Protex B &
Protekta SLM. This layer is a hard layer & will be
abrasion resistant.
• A coat of Protekta Ceal 540 on concrete
Treatment on –ve Side
• Injection/grouting at a regular intervals at all joints
between floor and column joints and construction
joints
Podium Slab with Gutter (Hard & Soft
Scapes)

Podium Slab
Assumptions Made:
• Gradient is provided in the slab at the time
of casting.
• Water from this sloped surface flows into
the Gutters.
• Ridge points are at the Podium Slab,
midway between the Gutters on either side.
Treatment Steps
• Brush / spray application of crystallisation/gel formation product
called Protekta Base which fills the fine pores with crystalline
silicate growth, coverage 2 Sq. M / Ltr.
• Brush application of one coat of Protekta Flexjoint on the
construction joint only. Thickness of application will be approx. 0.5
mm.
• Plastering 6” wide at the construction joints.
• Brush coat of Protekta Plastofelt to provide a very strong
flexible coating.
• Application of Protekta Abrasion resist as hard layer. After the
application of this layer, plastering is not required.
• Injections/Grouting at construction joints/cracks from below.

• Optional, a coat of Protekta Procoat or Protekta Wall Top

• Please note that we have not suggested any plastering on


our treatment since the final surface is abrasion resistant.
Gutter Treatment
• Brush / spray application of crystallisation/gel formation
product called Protekta Base which fills the fine pores with
crystalline silicate growth, coverage 2 Sq. M / Ltr.
• Brush application of one coat of Protekta Flexjoint on the
construction joint only. Thickness of application will be
approx. 0.5 mm.
• Plastering 6” wide at the construction joints.
• Brush coat of Protekta Plastofelt to provide a very strong
flexible coating.
• Application of Protekta Abrasion resist as hard layer. After
the application of this layer, plastering is not required.
• Injections/Grouting at construction joints/ Cracks from below.

Slope Creation:
• With M20 grade Concrete laid to slope.
Sunken Toilet – 4”Sunken
Sunken Toilet – 4”Sunken

Protekta Unicoat

Protekta- Sealant Protekta Flex Joint


F500 mortar packing
Protekta Durocoat

Protekta Base.
Sunken Toilet – 4”Sunken
Tiles

RCC Slab

Protekta Base Protekta Durocoat


Cleaning:
Sunken Toilet – 4” Sunken
• Surface cleaning by wire brush, removing loose mortar, dirt, grime etc
followed by water cleaning using Protekta Cleaning Agent.
• Testing by ponding water for 48 hours to know surface defects.
Defect Removal:
Construction Joint / Crack Repair / Through Hole:
• Packing beam and hollow block joint
• Create “V” groove to ½ “ depth and clean the surface with cleaning
agent.
• Pouring of Protekta Base up to the neck of the groove followed by
water washing.
• Pour additional Protekta Base at areas were ingress is too much.
• Remove excess Protekta Base from the surface and clean it again
with wire brush
• Brush coat Protekta Flexjoint.
• Packing the groove with silica sand mixed with Protekta Sealant 400 in the ratio
of 1:2 and brush coat Protekta Flexjoint at the same areas after 24 hrs.
• Chemical Grouting by Protekta Seal ABC. (If Required)
•Block Honeycombs / Voids if excessive leakage found by chemical grouting.
Waterproofing
• Spray of crystallization product called Protekta Base with a low
pressure pump followed by water curing for 2 to 3 times at
intervals of 2 hours between each curing (Coverage 2 to 2.5 Sq.M./
Ltr.)
• Spray excessive Protekta Base at weak areas.
• Spread Protekta Durocoat slurry (Brush application)
Slope Making /Filling:
• Slope making with M20 grade concrete (using 12 mm & 20 mm jelly,
mix ratio 1:1). Following additive to be mixed.
– Emulsion KR2 towards water resistance (125ml per cement bag)
• After 24 hours of curing, re-spray of Protekta Base with low
pressure pump.
• Packing the floor / Wall joints with Protekta Sealant 500 mixed
with Cement.
• Brush coat of Protekta Unicoat at Floor and Wall joints up to 300
mm of wall surface.
• Final testing for 7 days
Bore packing
* Brush coat of Protekta Base followed by
Protekta
Flexjoint surrounding the bore area.
* Coat Protekta Flexjoint and smear silica
sand for better
adhesion between PVC pipe and concrete
* Provide shuttering from bottom after pipe is
installed.
* Fill up the bore with Protekta Sealant 500
based mortar
using 6mm down size jelly.
* Brush coat of Protekta Flexjoint above the
Protekta
Sealant 500 based mortar to ensure sealing
of pipe to screed
Sunken Toilet –
9”Sunken

Plastering

Weep Hole
RCC Slab

Coping
Protkta Base
Protekta Durocoat
Sunken Toilet – 9” Sunken
Cleaning:
•Surface cleaning by wire brush, removing loose
mortar, dirt, grime.
• Testing by ponding water for 48 hours to know
surface defects.
Defect Removal:
Construction Joint / Crack Repair:
•Packing beam and hollow block joint.
•Create “V” groove to ½” depth and clean the surface
with cleaning.
•Pour into of Protekta Base up to the neck of the
groove followed
by water.
•Pour additional Protekta Base at areas were
ingress is too much.
Contd…
Porosity Reduction:
• Spray of crystallization product called Protekta Base
with a low pressure.
• Spray excessive Protekta Base at weak area.
Surface Preparation:
• Spread a slurry (Brush application) Protekta Durocoat
on the slab and wall up to 300 mm above floor level.
• Plastering with C:M 1:4 creating gradient towards weep
hole. Protekta KR2 to be added to mortar at 125
ml/bag of cement.
• Spray of Protekta Base.
• Curing cum testing for 7 days.
Area Calculation:
Floor + Wall up to 300 mm above floor level.
Bore Packing
Sunken Toilet 4 “ sunken
Tiles

RCC Slab

Protex A Protekta Flexjoint


tekta Sealant F500 based concrete
·        Clean the surface thoroughly.
·        Brush coat of Protekta Base.
·        Brush coat of Elastomeric coating,
Protekta
Flexjoint around the pipe
·        Application of Protekta Durocoat
slurry on the
bore surface.
·        Packing the bore with M20 grade
concrete by
using 12 mm downsize jelly.
Protekta KR2 to be
added in the concrete
·        Brush coat of Protekta Base
·        Brush coat of Protekta Flexjoint.
·        Curing for 7 days.
Beam & Block Wall Joints.

Protekta Unicoat

Protekta- Sealant Protekta Flex Joint


F500 mortar packing
Protekta Durocoat

Protekta Base.
Terrace

Protekta Unicoat
Parapet wall

Plastering

Rain Water Pipe


Coping

RCC Slab
Coping M20 Grade
concrete Duracoat Slurry
Protekta Base
Terrace/Terrace Garden
Pre Treatment Steps:
• Chip off loose mortar and clean the surface thoroughly.
Defect Removal:
• Construction joint will be treated by making groove,
stagnating
Protekta Base and Water Wash. Filling the groove with
F400
mortar.
• Brush coat of Elastomeric coating Protekta Flexjoint
only on
the construction joint.
Porosity Reduction:
• Brush application of impregnation product called
Protekta
Base which fills the fine pores with crystalline silicate
oSurface Preparation & Slope Making:
• Brush application of Protekta Durocoat slurry
Contd…
to a thickness
of approximate 1 mm. This slurry coating has a
very special
chemical, which impregnates through pores
and capillaries. It is
water based product and can be applied on
moist surfaces.
Slope Making
• With M20 concrete mixed with Emulsion KR2 in
proportion
of 125 ml/bag of cement. Average thickness
estimated – 65
mm to 75 mm.
• M-20 Grade RMC supplied free of cost.
Waterproofing
• Spray of Protekta Base.
• Curing for 7 days.
TERRACE / PODIUM SLAB WITH LANDSCAPING
[WATERPROOFING + SCREEDING + ELASTOMERIC COATING]
Pre Treatment Steps:
• Chip off loose mortar and clean the surface thoroughly.
Defect Removal:
• Construction joint will be treated by making groove, stagnating Protekta
Base and Water Wash. Filling the groove with F400 mortar.
• Brush coat of Elastomeric coating Protekta Flexjoint only on the
construction joint.
Porosity Reduction:
• Brush application of impregnation product called Protekta Base, which fills
the fine pores with crystalline silicate growth. Coverage 2 Sq. M/Ltr. of
Protekta Base.
• Making coping by polymer modified mortar at slab and parapet wall junction.
Surface Preparation & Slope Making:
• Brush application of Protekta Duracoat slurry to a thickness of approximate
1 mm. This slurry coating has a very special chemical, which impregnates
through pores and capillaries. It is water based product and can be applied on
moist surfaces.
Slope Making
• With M20 concrete mixed with Emulsion KR2 in proportion of 125 ml/bag of
cement. Average thickness estimated – 65 mm to 75 mm.
• M-20 Grade RMC supplied free of cost @ 0.075 Cu. M/Sq. M
Waterproofing
• Spray of Protekta Base.
• Curing for 7 days.
Water Tank
Construction Joint

Protekta Flex Joint


Protekta Unicoat

Protekta Base
Protex B Slurry

Plastering

Concrete
Coping
NOT TO SCALE

OH WATER TANK/SWIMMING POOL/SUMP (INSIDE SUR


FACE)
WATERPROOFING + SCREEDING /PLASTERING + ELASTOMERIC COATING

Waterproofing & Plastering


Grouting on starter/construction

Grouting on starter/construction
Protekta Base

Protekta Unicoat
joint

joint
Protekta Duracoat
Protekta G

RCC Slab
OH WATER TANK/SWIMMING POOL/SUMP (INSIDE SURFACE)
WATERPROOFING + SCREEDING /PLASTERING + ELASTOMERIC COATING]

Defect Removal:
• Grouting of slab and beam joint with Protekta SB Grout OR
Protekta Hydrogrout.
• Testing by water stagnation for 48 hours.
• Re-grouting if seepage / dampness is noticed.
• Surface cleaning by wire brush, removing loose mortar, dirt, grime
etc followed by water cleaning using cleaning agent.
• Coving the slab and wall joint using polymer modified mortar.
[
Porosity Reduction:
• Brush application of impregnation product called Protekta Base,
which fills the pores with crystalline silicate growth. Covering 2 Sq. M/Ltr.
Of Protekta Base.
Surface Preparation:
• Brush application of Protekta Duracoat slurry to a thickness of
approximate 1 mm. This slurry coating has a very special chemical,
which impregnates through pores and capillaries. It is water-based
product and can be applied on moist surfaces. Sprinkle Sand to keep the
surface rough for plastering/concreting.
For Floor:
• Concreting with M20 mix using (12 mm jelly) average thickness 50
mm.
• Emulsion KR2 to be added to increase water resistance (125 ml per
cement bag)
For Wall:
• Specialized plastering with an average thickness of 15 mm to 18
mm.
• Emulsion KR2 to be added to increase water resistance (125 ml per
cement bag)
• Curing for two weeks.
Waterproofing:
• Spray of Protekta Base.
• Spray of Protekta G towards water repellency.
• Brush coat of Protekta Unicoat on the entire surface. Coverage
(1.5 to 2 Sq. M / Ltr.) surface area.
• Sprinkle Silica Sand to keep the surface rough for plastering. [If
required]
 
Note: One coat of Protekta Unicoat for inner surfaces of STP,
which is a acid alkali resistant coating.
For Floor:
·     Concreting with M20 mix using (12 mm & 20 mm jelly,
ratio 50:50) average thickness 50 mm.
For Wall:
·     Specialized plastering with an average thickness of 18
mm to 20 mm.
·     Emulsion KR2 to be added to increase water
resistance
(125 ml per cement bag)
·     Curing for two weeks.
Waterproofing:
·     Spray of Protekta Base.
·     Brush coat of Protekta Unicoat on the entire surface.

Coverage(1.5 to 2 Sq. M / Ltr.) surface area.


Waterproofing up to 200 mm above finished floor level.

Block Work

20 mm plaster mixed with Emulsion KR2 (sloped to weep hole)

Brick bat Coba Protekta Duracoat

Coving with polymer modified mortar


50 mm Screed
r Protekta Base Grouting

Floor Slab
Bore packing as
detailed

RCC Slab

Weep Hole O

No. Item Toilet Utility


01. Sunken Depth 250 mm 150 mm
02. Waterproofing ht. A bove Finished Floor level 300 mm 300 mm
03. Waterproofing Plaster thickness 20 mm 20 mm
04. Screed Thickness 50 mm 50 mm
05. Brickbat thickness 175 mm 75 mm

Sunken Toilet/Utility Waterproofing + Brickbat + Screed


Sunken Area Waterproofing – Toilet/Utility/Balcony [200mm
Sunk]
Pre-treatment steps:
• Surface cleaning by wire brush, removing loose mortar, dirt, grime.
• Testing by ponding water for 48 hours to know surface defects.
Defect Removal:
Construction Joint / Crack Repair
• Packing beam and hollow block joint.
• Create “V” groove to ½” depth and clean the surface with cleaning.
• Pour into of Protekta Base up to the neck of the groove followed
by water.
• Pour additional Protekta Base at areas were ingress is too much.
• Remove excess Protekta Base from the surface and clean it again
with brush coat of Protekta Flexjoint.
• Packing the groove with silica sand mixed with Protekta Sealant
400.
• Chemical Grouting by Protekta Seal ABC (If Required)
• Block Honeycombs / Voids if excessive leakage found by chemical.
Porosity Reduction:
• Spray of Crystallization product called Protekta Base with a low
pressure.
• Spray excessive Protekta Base at weak area.
Surface Preparation:
• Spread a slurry (Brush application) Protekta Duracoat on the
slab and wall up to 300 mm above finished floor level.
Floor & Wall Plastering:
• Plastering with C:M 1:4. In the floor creating gradient towards
weep hole. Protekta KR2 to be added to mortar at 125
ml/bag of cement.
• Spray of Protekta Base.
• Curing cum testing for 7 days.
Area Calculation = Floor + Wall up to 300 mm above
finished floor level.

Bore packing in the wall:


• Clean the surface thoroughly.
• Brush coat of Protekta Base.
• Brush coat of Elastomeric coating, Protekta Flexjoint around
the pipe
• Application of Protekta Duracoat slurry on the bore surface.
• Packing the bore with M20 grade concrete by using 12 mm
downsize jelly. Protekta KR2 to be added in the concrete
• Brush coat of Protekta Base
PLANTER BOX WATERPROOFING
WATERPROOFING + SCREEDING /PLASTERING + ELASTOMERIC COATING
Sunken Toilet (100 mm Sunk)
• Surface cleaning by wire brush, removing loose mortar, dirt, grime
etc followed by water cleaning using Protekta Cleaning Agent.
• Testing by ponding water for 48 hours to know surface defects.
Defect Removal:
a. Construction Joint / Crack Repair / Through Hole:
• Packing beam and hollow block joint
• Create “V” groove to ½” depth and clean the surface with cleaning
agent.
• Pouring of Protekta Base at areas were ingress is too much.
• Remove excess Protekta Base from the surface and clean it again
with wire brush.
• Brush coat Protekta Flexjoint.
• Packing the groove with silica sand mixed with Protekta Sealant
400 in the ratio of 1:2 and brush coat Protekta Flexjoint at the
same areas after 24 hours.
b. Chemical Grouting by Protekta Seal ABC. (If Required)
• Block Honeycombs / Voids if excessive leakage found by chemical
grouting.
Porosity Reduction:
• Spray of crystallization product called Protekta Base with a low
Surface Preparation:
• Spread Protekta Duracoat slurry (Brush application)
Concreting:
• Filling with M20 grade concrete (using 12 mm & 20 mm jelly, mix
ration 2:1). Following additives to be mixed.
• Add Protekta Emulsion KR2 towards water resistance (125ml per
cement bag)
Waterproofing:
• Aftter 24 hours of curing, re-spray of Protekta Base with low-
pressure pump
• Packing the floor / wall joints with Protekta Sealant 500 mixed with
cement.
• Brush coat of Protekta Unicoat at floor and wall joints up to 300
mm of wall surface.
• Final testing for y days.
Area Calculation
For Waterproofing = Floor + Wall up to 300 mm above finished
floor level
For Concreting = Floor only

Bore Packing:
• Brush coat of Protekta Base followed by Protekta Flexjoint
Expansion Joint
Protekta Flexjoint

Sealant 400 Mortar + Non-stick tape

RCC Slab

Protekta EJR Thermocol Packing


Expansion Joint
Horizontal Expansion Joint:
• Removal of thermocole / Shalitex board up to 20 mm from
top & Clean the surface thoroughly
• Brush coat of Protekta Sealant 400 Special as primer on side
walls.\
• Application of Special Sealant 400 based mortar on top of
thermocole / Shalitex Board
• Fill the joint with Protekta EJR (H) up to top (in multiple fills of
app. 3 mm to 4 mm each fill)
• Application of mortar prepared with sealant 400.
• Concreting / Plastering as mechanical protection.
Vertical Expansion Joint:
• Removal of thermocole / Shalitex board up to 15 mm from top &
Clean the
surface thoroughly
• Brush coat of Protekta Sealant 400 Special as primer.
• Filling the joint with EJR Vertical
• Brush coat of Protekta Abrasion result as mechanical protection
Construction Joint / SlabCracks
Protekta Flexjoint

F400 Mortar Packing

Crystallization Gel of Protekta Base

Construction Joint Crack


Construction Joint / Slab
Cracks
• Create “V” groove to ½ “ depth and clean the
• surface with cleaning agent.
• Pouring of Protekta Base up to the neck of the
groove followed by water washing.
• Pour additional Protekta Base at areas was
ingress is too much.
• Remove excess Protekta Base from the
surface and clean it again with wire brush.
• Brush coat Protekta Flexjoint.
• Packing the groove with silica sand mixed with
Protekta Sealant 400 in the ratio of 1:2 and
brush coat Protekta Flexjoint at the same
areas after 24 hrs
Products Used
1. Grouting Products:
• Protekta SB
• Protekta Hydrogrout
• Protekta ABC
• Protekta Grip (2 component)

2. Crystallisation / Gel Formation:


• Protekta Base.
• Bonding Layer
* Protekta Duracoat
* Protekta Sealant 500
• Admixtures:
* Protekta Emulsion KR2
* Protekta GL – 8
* Anti Shrinkage AC – 1
• Water Repellency:
* Protekta G
* Protekta Micro emulsion.
• Elastomeric Coating:
* Protekta Flexjoint.
* Protekta Unicoat.
• Abrasion Resistant Layer:
* Protekta Abrasion
• Polymers for Mortar
modifying:
* Protekta Sealant 400
* Protekta Sealant 500
 
COMBO SOLUTION FOR THERMAL
INSULATION

Parapet Wall
dditional Thermal insulation
layer [Protekta KP]

Waterproofed Lightweight Concrete


Average thickness 75 mm to 100 mm
50 mm

Down tank pipe


Coving
Waterproofing Construction
Treatment Joint Repair
TREATMENT DETAILS
I. WATERPROOFING:
- Chipping, Cleaning & Testing.
- Defect Removal : Repair of Construction Joints.
: Honeycomb / Hollowness
- Crystallisation application.
- 2 coats of Polyurea Eleastomeric coatings.

II. SLOPE CREATION WITH THERMAL INSULATION MATERIAL:


- Density = 780 Kg/Cu. M
- Strength = > 10 mpa
- Av. Thickness = 100 mm
- Thermal Conductivity = 0.125 Kcal/hrs/m2/C

III. PLASTERING LAYER OF 15MM TO 18 MM


- 1:4 Mix.
- Emulsion KR2 added.
- Fibre mesh applied

IV. Additional Thermal Shield:


- 2Coats of Protekta Thermal Flexicoat.
- Thermal Conductivity = 0.032 Kcal/hrs/m2/C
- Average thickness = 1 mm to 1.5 mm.