PRECAUTIONS
PF GOLD 19
Technical Service Data
SERVICE WARNING
SERVICE SAFETY CHECKS — FIRE AND SHOCK HAZARD
Only qualified service technicians who are familiar with safety checks Cold Leakage Chec
Leakag ks ffor
Checks or Receiver
Receiverss with Isolated Ground
Ground PHILIPS
PF GOLD 19
and guidelines should perform service work. Before replacing parts,
Unplug the AC cord, connect a jumper across the plug prongs, and turn
disconnect power source to protect electrostatically sensitive parts. Do
the power switch on (if applicable). Use an ohmmeter to measure the Model 64P8341 (Chassis PTV915)
not attempt to modify any circuit unless so recommended by the INDEX
manufacturer. When servicing the receiver, use an isolation transformer resistance between the jumped AC plug and any exposed metal cabinet
between the line cord and power receptacle. parts such as antenna screw heads, control shafts, or handle brackets.
Exposed metal parts with a return path should measure between 1M GridTrace Location
SERVICING THE HIGH VOL
SERVICING TAGE AND CR
OLT T
CRT ohms and 5.2M ohms. Parts without a return path must measure infinity.
LSB Board - Bottom View ................ 7
Use EXTREME CAUTION when servicing the high voltage circuits. To
Hot Leakage Current Chec
Leakag Checkk SSM Board - Bottom View ............... 7
discharge static high voltage, connect a 10K ohms resistor in series with a
test lead between the receiver ground and CRT anode lead. DO NOT lift Plug the AC cord directly into an AC outlet. DO NOT use an isolation IC Functions ............................................. 1
the CRT by the neck. Always wear shatterproof goggles when handling transformer. Use a 1500 ohms, 10W resistor in parallel with a .15µF Important Parts Information ..................... 7
the CRT to protect eyes in case of implosion. capacitor to connect between any exposed metal parts on the receiver and
a good earth ground. (See figure below.) Use an AC voltmeter with at
Miscellaneous Adjustments ...................... 1
X-RAY RADIA
X-RAY TION AND HIGH VOL
RADIATION TAGE LIMITS
OLT least 5000 ohms per volt sensitivity to measure the voltage across the M0226 Connector Information ................ 7
Be aware of the instructions and procedures covering X-ray radiation. In resistor. Check all exposed metal parts and measure voltage at each point. Parts List ................................................... 8
solid-state receivers and monitors, the CRT is the only potential source of Voltage measurements should not exceed .75VAC, 500µA. Any value Placement Chart ....................................... 6
X-rays. Keep an accurate high voltage meter available at all times. Check exceeding this limit constitutes a potential shock hazard and must be Safety Precautions .................................... 1
meter calibration periodically. Whenever servicing a receiver, check the corrected. If the AC plug is not polarized, reverse the AC plug and repeat
exposed metal part voltage measurement at each point. Schematic Component Location .............. 6
high voltage at various brightness levels to be sure it is regulating
properly. Keep high voltage at rated value, NO HIGHER. Excessive high Schematic Notes ....................................... 2
voltage may cause X-ray radiation or failure of associated components. Schematics
DO NOT depend on protection circuits to keep voltage at rated value. Audio ................................................. 4
When troubleshooting a receiver with excessive high voltage, avoid close Comb Filter ....................................... 4
contact with the CRT. DO NOT operate the receiver longer than
necessary. To locate the cause of excessive high voltage, use a variable
Convergence ...................................... 5
• Schematics
Schematics
• Component locations
• Par ts list
arts
Coverage includes these additional models and chassis:
Models Chassis
PF GOLD 19
PF GOLD 19
50P8341 PTV915
The listing of any available replacement part herein in no case constitutes a recommendation, warranty, or guarantee by 55P8341 PTV915
SAMS Technical Publishing as to the quality and suitability of such replacement part. The numbers of the listed parts have 60P8341 PTV915
been compiled from information furnished to SAMS Technical Publishing by the manufacturers of the specific type of
replacement part listed.
Reproduction or use, without express permission, of editorial or pictorial content, in any manner, is prohibited. No patent
liability is assumed with respect to the use of the information contained herein.
© 2003
UPC
5436 West 78th Street HERE
Indianapolis, IN 46268-4149 For Supplier Address,
Address,
See PHO
PHOTTOFACT Ann
OFA ual Inde
Annual Indexx
PHILIPS
PHILIPS
PLST Program List OFF/ON ON
Press menu button for next menu. Press adjust right/left to either turn selection on / Delta Cool >>>> Red -2 SOSD Smart OSD OFF/ON ON
off or to proceed to next menu. Press the adjust up/down to make a selection. Green 0 BLMU Blue Mute OFF/ON OFF
Blue 11 PIPC PIP Control OFF/ON ON
NOTE: Only four selections are displayed at a time. Use arrow up/down buttons for Black Level Delta Cool Red 1 PIPT PIP Tuner OFF/ON OFF
more. Black Level Delta Cool Green 1 VSLC Vertical Slicing OFF/ON ON
SURF Surf Feature Available OFF/ON ON
A101US1 - 2.6 SAM Delta Warm >>>> Red 2 CCAP Closed Caption OFF/ON ON
AKB ON Green 0 DNRM DNR Function Available OFF/ON ON
Blue -7 Error Codes
Error NVCK Non Volatile Clock OFF/ON OFF
VSD OFF
PF GOLD 19 P
Paage 1
Page 2 PF GOLD 19
PF GOLD 19 P
Paage 2
Page 2 PF GOLD 19
PHILIPS MODEL 64P8341 (CHASSIS PTV915)
Paage 2
P
PF GOLD 19
Page 3 PF GOLD 19
PF GOLD 19 P
Paage 3
Page 3 PF GOLD 19 PF GOLD 19 P
Paage 3
PHILIPS MODEL 64P8341 (CHASSIS PTV915)
Paage 3
P
PF GOLD 19
Page 4 PF GOLD 19
PF GOLD 19 P
Paage 4
Page 4 PF GOLD 19
PHILIPS MODEL 64P8341 (CHASSIS PTV915)
Paage 4
P
PF GOLD 19
Page 5 PF GOLD 19
PF GOLD 19 P
Paage 5
Page 5 PF GOLD 19 PF GOLD 19 P
Paage 5
PHILIPS MODEL 64P8341 (CHASSIS PTV915)
Paage 5
P
PF GOLD 19
Page 6 PF GOLD 19
LSB BOARD - BO
BOARD TT
BOTTOM VIEW
TTOM VIEW,, GRIDTRACE LOCA
GRIDTRACE TION GUIDE
LOCATION
C2513 L3 C2914 E4 D6911 E5 Q7908 F4 R3319 B17 R3501 L2 R3800 L7 R3913 E5
C2514 L2 C2915 K6 D6912 F5 Q7909 E4 R3326 G15 R3503 L2 R3802 K8 R3914 E5
C2556 L8 C2919 F4 D6920 F4 R3223A G21 R3327 G15 R3504 L2 R3803 L7 R3918 K6
C2564 K3 D6500 L2 D6921 F4 R3240A H20 R3328 H15 R3506 L3 R3814 J8 R3942 F2
C2567 L3 D6501 L2 D6922 F3 R3244A G20 R3329A G15 R3511 L2 R3820 L4 R3967 A6
C2570 L3 D6502 L2 D6951 A6 R3245 H20 R3334 I18 R3550 J3 R3866 L8 R3968 F2
C2571 J3 D6503 L2 Q7500 L2 R3303 H17 R3335A J19 R3551 L3 R3901 F5 R3969 B7
C2572 K3 D6551 L3 Q7501 L1 R3304 H16 R3339A J19 R3571 K5 R3902 E4 R3990 F3
C2807A L5 D6809 A9 Q7551 K6 R3306 C16 R3340A J19 R3581 J6 R3903 E4 R3991 A6
C2823A A9 D6810 A10 Q7553 K5 R3313 B17 R3343 H17 R3590 K5 R3904 F4
C2907 K6 D6900 F4 Q7590 K3 R3315A B17 R3344A H17 R3591 K6 R3907 F4
C2908 K6 D6905 F3 Q7800 L8 R3316A A17 R3456 K6 R3592 K6 R3909 F4
C2909 F5 D6907 G4 Q7906 F3 R3317A B17 R3458 K5 R3594 L4 R3911 F5
C2910 F5 D6910 F5 Q7907 E5 R3318A C17 R3500 L2 R3596 J6 R3912 E5
TEST EQUIPMENT
EQUIPMENT
PHILIPS
C2023 F13 C2604 I13 D6613 I13 R3039 I16 R3203 H2 R3500A D2 R3641 I13 ZD6708 K5
C2024 G16 C2605 B6 IC7003 F17 R3040 D17 R3204 H2 R3501A D3 R3642 I13
C2025 H17 C2607A B5 IC7009 G20 R3041 H17 R3205 I8 R3502 D2 R3643 F11 articipating
Par endorss
ticipating Vendor
C2026 H16 C2609 I12 IC7010 H20 R3042A H17 R3206 I3 R3503A D3 R3645 G11
C2027 H16 C2610 D5 IC7011 F20 R3043A D12 R3207 I8 R3504A D3 R3647 I15
C2028 H15 C2612A D5 IC7711 F4 R3044A D11 R3208 G2 R3505A D3 R3648 I13
Information on test equipment and replacement parts is listed in these pages for the following participating vendors.
C2029 H17 C2617 I12 IC7712 F5 R3045A D11 R3209 H3 R3506A C2 R3652 H11 Consult the Sams Annual Index for their current address.
C2031 G19 C2618 I12 L5602 I13 R3046A B19 R3211 I1 R3507A C3 R3653 H11 NTE Electronics, Inc. (NTE)
C2036 H19 C2619A H11 Q7002 H16 R3047 C19 R3212 I1 R3508A C2 R3654 J11
ν ν Sencore, Inc.
C2041A F19 C2620A J11 Q7004 H17 R3048 D17 R3216 I2 R3509A C2 R3655 H11
PF GOLD 19 P
Paage 7
Page 8 PF GOLD 19
PARTS LIST
Page 8 PF GOLD 19
PARTS LIST continued
PHILIPS
# R3720, 20A 5.6 1% 2322 156 25608 - Coupler (4) 3135 011 03634 CRT Lens, Blue
# R3730, 30A 3300 5% 5W 2322 257 41332 - Coupler 3135 011 04281 CRT Lens, Green
# R3731, 31A 3300 5% 5W 2322 257 41332 - Coupler (1) 3135 011 02555 CRT Lens, Red
R3742, 42A 1000 1% 2322 156 21002 - Coupler (2) 3135 011 04271 CRT Lens, Red
R3743, 43A 220 1% 2322 156 22201 - Coupler (3) 3135 011 01934 CRT Lens, Red
R3745, 45A 75 1% 2138 116 17509 - Coupler (4) 3135 011 03634 CRT Lens, Red
R3751, 51A 15 1% 2138 116 11509 - Lens C-Element 3135 013 01081 Blue
# R3801 .47 5% 1W 2120 106 90556 - Lens C-Element 3135 013 01081 Red
R3810, 11 1500 5W 2322 257 41152 - Lens C-Element 3135 013 01071 Green
# R3815 .27 5% Fusible 2322 207 90048 - Lens Delta-77 3135 013 01052 Blue
PF GOLD 19 Page 8