Sie sind auf Seite 1von 4

GRR vs Minitab command

Editor : Richard 1

illustration

A B C

1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10

ƒChoose Gage R&R Study (Crossed) or


Gage R&R Study (Nested) ?

Editor : Richard 2
Choose Stat > Quality Tools > Gage Study > Gage R&R Study
(Crossed)

Editor : Richard 3

Select
“ANOVA”
study

Editor : Richard 4
„ Subsequent 4 steps as below :

1. Click
“Options”

2. Fill in the value


of Process
tolerance &
Historical Std

4. Click
“OK”
3. Click
“OK”
Editor : Richard 5

„ The gage R&R study result in Session window

Editor : Richard 6
2 2 2
σ = σProcess + σMeasurement System
Observed
2
= σPart To Part σ2
+ 2RPT + σ2
RPD

= σPart To Part + σ RPT + σOperator + σ


2 2
Operator * part

%Contribution
Source VarComp
(of VarComp)
Total Gage R&R 0.0012892 11.44
Repeatability 0.0004033 3.58
Reproducibility 0.0008858 7.86
Operator 0.0002584 2.29
Operator*Part 0.0006274 5.57
Part-To-Part 0.0099772 88.56
Total Variation 0.0112664 100

Editor : Richard 7

StdDev Study Var %Study %Tolerance %Process


Source
(SD) (6 * SD) Var(%SV) (SV/Toler) (SV/Proc)
Total Gage R&R 0.035905 0.21543 33.83 26.93 35.9
Repeatability 0.020083 0.120499 18.92 15.06 20.08
Reproducibility 0.029763 0.178578 28.04 22.32 29.76
* Operator 0.016076 0.096454 15.15 12.06 16.08
Operator*Part 0.025048 0.150289 23.6 18.79 25.05
Part-To-Part 0.099886 0.599316 94.1 74.91 99.89
Total Variation 0.106143 0.636859 100 79.61 106.14
P/SV P/T P/TV Distinct
% Con (% SV) (% Tolerance (% Process
Categories
or SV/Toler) or SV/Proc)

Acceptable < 1% < 10% < 10% < 10% > 5


Maybe Acceptable 1 – 9% 10 – 30% 10 – 30% 10 – 30% 3 - 4

Not Acceptable > 9% > 30% > 30% > 30% < 3
Result 11.44 % 33.83 % 26.93 % 35.90 % 3