Sie sind auf Seite 1von 1

PAGE : 1 OF 1

REV. 0 1 2
BY
CHKD
APVD
DATE

1 SERVICE : CYCLONES SPECIFICATION :


2 NR. REQUIRED : 2 TYPE :
3 SURFACE PER SHELL : MANUFACTURER :
4 SHELL PER UNIT : MODEL :
5 SURFACE PER UNIT :
6 DESIGN DATA
INLET CONDITIONS
7 DRY AIR (Kg/h) 21000
8 RELATIVE HUMIDITY % 30 - 50
9 DUST (Kg/h)
10 GAS (Kg/h) # (1)
11 ACTUAL FLOW (m3/h) 21000 (1)
0
12 TEMPERATURE C 40-50 MAX 55
13 BASIC PRESSURES OPERATING DESIGN
14 ABSOLUTE x RELATIVE
15 INTERNAL mm w.c : - 230 (1)
16 EXTERNAL OR VACUUM : ATM
17 DUST CHARACTERISTICS
18 MATERIALS FERTILIZER DUST
19 HYGROSCOPIC YES
20 BULK DENSITY (Kg/m3) 1000 - 1150
21 SIZE ANALYSIS (CUMMULATIVE %) > 350 µ 60%
22 > 100 µ 80%
23 > 20 µ 92%
24 >5 µ 95%
25 OTHERS
26 DUTY (H/DAY) 24
27 MAX. ALLOWABLE CLEAN 100
28 PRESSURE DROP (mm H2O col) DIRTY 150
29 DESIGN MIN. OVERALL EFF. % 95% DUST > 20µ
30 NUMBER OF CYCLONE BODIES 1
31 POSITION OF CYCLONE BODIES SINGLE X SPECULAR LINEAR
32 DUST COLLECTION HOPPER COMMON x INDIVIDUAL
33 AIR LOCK VALVE ROTARY VALVE
34
35
36 INTERNAL CHAINS YES
37 HEAT INSULATION NO
38 ACOUSTIC INSULATION NO
39 MATERIALS
40 C.STEEL S.STEEL RUBBER
41 CYCLONE CYLINDER 6 mm
42 CYCLONE CONE 6 mm
43 HOPPER 6 mm
44 CYCLONE INLET SHELL 6 mm
45 FLANGE PLATE 10 mm
46 VALVE BODY
47 VALVE INTERNALS
48 REMARKS :
49 (1) SHOULD BE CHECK & VERIFIED BY VENDOR
50 (2) COMPLETE WITH ROTARY VALVE FOR EACH UNIT
51
Data Sheet Cyclone.xls