Sie sind auf Seite 1von 18

Internal

UPDATE THE NODEB WITH M2000


www.huawei.com

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Before starting work on site, you need to enter the following command on the side of BSC
    

enter SET BTSAUTODLDACTINFO in the Command Input box, and then click Assist. Set the parameters displayed below the Command Input box as follows: Index Type: BYNAME(By Name) or BYID(By Index) Auto Download Active Function Switch: OFF(OFF). Then, click Exec.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Connect your laptop to the Ethernet port of GTMU

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 3

Setting the IP Address of the Site Maintenance Terminal PC


 

Procedure To set the IP address of the PC, perform the following steps: Choose Start> Setting > Control Panel. Double-click Network Connections in the displayed Control Panel window. Right-click Local Area Connection in the displayed dialog box. Choose Properties from the shortcut menu. The Local Area Connection Properties dialog box is displayed. Select Internet Protocol (TCP/IP), and click Properties. The Internet Protocol (TCP/IP) Properties dialog box is displayed. Select Use the following IP address. Enter the correct IP address, subnet mask. (192.168.0.71 or other in the same segment) Ensure that the IP address of the SMT PC is in the same network segment as the IP addresses (192.168.0.72/255.255.255.0) of the BTS so that a maintenance channel on the BTS side can be established. Click OK to complete the settings. All rights reserved

      

HUAWEI TECHNOLOGIES CO., LTD.

PING THE BTS


 On the command prompt of your computer, run ping 192.168.0.72  If the information similar to that in the following example is

returned, the SMT PC and the BBU can communicate normally.

 Pinging 192.168.0.72 with 32 bytes of data: Pinging 192.168.0.72    

with 32 bytes of data: Reply from 192.168.0.72: bytes=32 time=1ms Reply from 192.168.0.72: bytes=32 time=1ms Reply from 192.168.0.72: bytes=32 time=1ms Reply from 192.168.0.72: bytes=32 time=1ms

TTL=253 TTL=253 TTL=253 TTL=253

 Ping statistics for 192.168.0.72: Packets: Sent = 4, Received = 4,

Lost = 0 (0% loss), Approximate round trip times in milli-seconds: Minimum = 1ms, Maximum = 1ms, Average = 1ms

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

OPEN THE SMT

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 6

SETTING THE PARAMETERS TO CONNECT TO THE BTS


To connect to the BTS with the SMT: 1. Select Network Port 2. Input the ip 192.168.0.72 3. Click ok

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

GET THE MANAGEMENT RIGHTS

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

CLICK GET

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

CONFIRMATION OF THE MANAGEMENT RIGHTS ACQUIRED

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Checking the Software Versions of the BTS Boards


 Click Board in the navigation tree, and then double-click

Board Management in the Function pane on the right

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

 In the displayed Board Management window, right-click the GTMU and

then choose Board Information from the shortcut menu.


 The Board Information dialog box is displayed

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Loading the GTMU Software




On the SMT, click Site in the navigation tree, and then double-click Forced Software Load in the Function pane on the right,

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

In the displayed Software Download dialog box, set the associated parameters
> > > > File Name: Specify the path and name of the target software package required for the upgrade. Send Window Size: 200 Version: Type V100R009C00SP72 in the lower box. File ID: Select GTMU_MAIN from the drop-down list.

 

Click Start. When the progress bar displays "100%" in the lower corner and the status bar displays "Loading Software Successfully", click Close

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Activating the GTMU Software




On the SMT, click Site in the navigation tree, and then double-click Software Activation under Function.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

 In the displayed dialog box, set the associated parameters as follows:

> Version: Type V100R009C00SP72 in the lower box. > File ID: Select GTMU_MAIN from the drop-down list. > Board No.: You are not required to set this parameter.
 Click OK..  When the status bar displays "Activation is confirmed and the Site will

be reset in a few minutes", click Close.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Checking the Software Versions of the BTS Boards


  

Verify that the software is loaded correctly: > close and restart BTSM Click Board in the navigation tree, and then double-click Board Management in the Function pane on the right In the displayed Board Management window, right-click the GTMU and then choose Board Information from the shortcut menu. The Board Information dialog box is displayed