Lambley Park Lighting and Electrical Schedule

Ground Floor -Exterior


Area Entrance Snooker Room Dining Room Lounge Utility Bedroom-1 Driveway Pathway Driveway Split Pump at the well Lighting 2 x highly decorative 1 x decorative 1 x PIR 2 x lower spec decorative 1 x PIR 2 x lower spec decorative 1 x lower spec decorative 1 x PIR 1 x decorative 1 x PIR subdued wall lighting down driveway subdued lighting down pathway 1 x decorative Sockets Either side of the front door Corner nearest lobby Northern side Either side of Bay Northern side Either side of Bay Corner to terrace Outside side utility door Corner nearest lobby Southern side

1 weatherproof

1 weatherproof

shielded cable shielded cable shielded cable shielded cable

To be used for garden irrigation

Ground Floor - Interior


Room Entrance Lobby Entrance Hall Snooker Room Dining Room Kitchen Lounge GF-W/C Bedroom-1 Ensuite-1 Utility Corridor Utility Room Utility W/C Plant Room Lighting Sockets 1 x ceiling 0 4 x wall, 2 x ceiling 1 x double, 4 x single 5 x wall, 2 x ceiling, 2 x spots, 1 x snooker table light 6 x double 6 x wall, 2 x ceiling 4 x double 2 x wall, 4 x flourescent (recessed) 6 x double, 2 oven 5 x wall, 2 x ceiling 5 x double 1 x ceiling 0 4 x wall, 1 x ceiling 4 x double 3 x ceiling spots, 1 x ceiling 1 x shaver 2 x ceiling (either side door) 0 2 x flourescent 4 x double 1 x ceiling 0 1 x ceiling 2 x double + fittings (see notes)

First Floor - Interior


Room Landing Bedroom-2 Ensuite-2 Bedroom-3 Ensuite-3 Bedroom-4 Ensuite-4 Bedroom-5 Ensuite-5 Bedroom-6 Ensuite-6 Bedroom-7 Ensuite-7 Linen Cupboard Private Corridor Private Stairs Lighting 6 x wall, 1 x ceiling 4 x wall, 2 x ceiling 2 x ceiling spots, 1 x centre 4 x wall, 2 x ceiling 2 x ceiling spots, 1 x centre 4 x wall, 1 x ceiling 2 x ceiling spots, 1 x centre 4 x wall, 1 x ceiling 2 x ceiling spots, 1 x centre 4 x wall, 3 x ceiling 2 x ceiling spots, 1 x centre 4 x wall, 1 x ceiling 3 x ceiling spots, 1 x centre 1 x ceiling 1 x ceiling 1 x ceiling Sockets 2 x double 4 x double 1 x shaver 4 x double 1 x shaver 4 x double 1 x shaver 4 x double 1 x shaver 4 x double 1 x shaver 4 x double 1 x shaver 0 1 x double 0

2nd Floor - Interior


Room Landing Attic Room NOTES Plant Room Attic Room Lighting 1 x ceiling 2 x ceiling Wiring required but not necessarily to a standard socket The plant room has connections for ASHP, 1 x Ecocent, Central Vac, Solar PV inverters, Wind Turbine Inverters The void within the attic space will contain 1 x Ecocent and the MVHR Sockets 0 2 x double