Beruflich Dokumente
Kultur Dokumente
low-voltage
MOTORS
Squirrel-Cage Motors
Sizes 56 to 450
Output 0.06 kW to 1000 kW
MICROMASTER
MICROMASTER 410/420/430/440
Inverters
DA 51.2
Order No.:
German: E86060-K5151-A121-A4
English: E86060-K5151-A121-A4-7600
MICROMASTER/COMBIMASTER
DA 51.3
MICROMASTER 411 Inverters
Distributed Drive Solutions
COMBIMASTER 411
Order No.:
German: E86060-K5251-A131-A2
English: E86060-K5251-A131-A2-7600
SIVOLT A/V
DA 68
Alternating current and three-phase
current controller
(available only in German)
Order No.:
German: E20002-K4068-A101-A1
Components for automation
CA 01
Order No.:
German: E86060-D4001-A100-C1
English: E86060-D4001-A110-C1-7600
A&D Mall
Internet
http://www.siemens.com/automation/mall
Trademarks
COMBIMASTER, DURIGNIT, ECOFAST, LOGO!,
MICROMASTER, SIMATIC, SIMOTION and SIMOVERT
are registered trademarks of Siemens.
Other names in this catalogue may be trademarks
which, if used by third parties for their own purposes,
may violate the rights of the trademark owner.
Low-Voltage
Motors
Catalogue M 11
2003/2004
Introduction
Technical information
2
1LA and 1LG squirrel-cage motors
3
Selection and ordering data
Supersedes:
Catalogue M 11 2002/2003
Squirrel-cage motors
Sector solutions
Dimensions
7
The products and systems described in this
catalogue are manufactured under application of a certified quality
management system
in accordance with
DIN EN ISO 9001
(Certificate Registration
No. DE-000357 QM).
The certificate is recognized in all IQNet countries.
8
Appendix
Welcome to
Automation and Drives
1/2
Siemens M 11 2003/2004
Siemens M 11 2003/2004
1/3
1/3
Squirrel-cage motors
Introduction
1/4
Siemens M 11 2003/2004
Worldwide operation
thanks to compliance with
national (DIN/VDE) and
international standards
(IEC/EN)
Development and production with materials in
accordance with the
Siemens standard
SN 36 350 for environmentally compatible
products
Environmentally friendly
production technology
Highly qualified engineering advice locally
thanks to our global sales
network
Worldwide service
High-speed logistics system
50,000 standard motors
always in stock
Squirrel-cage motors
Introduction
Low-voltage motors,
surface air cooled, IP55 degree of protection
The "modular installation
concept" with rotary pulse
encoder, separately driven fan and brake makes
special designs superfluous. This mounting technology makes the 1LA
standard motors, quick,
easy and economical to
use in any application.
The "modular installation
concept" reduces costs
for installation, commissioning and stock keeping (for further details, see
"Modular technology" in
Section 2 "Technical information").
Basic version
Energy-saving motors
eff1, eff2, EPACT
pole-changing
For converter-fed operation
1LA and 1LG,
see Section 3
Increased safety
EEx e ll type of
protection
1MA see Section 4
Explosion-proof
enclosure
EEx de llC type of
protection
1MJ see Section 5
Sector solutions
Smoke extraction motors,
marine motors
See Section 6
Siemens M 11 2003/2004
1/5
Terminal boxes
Page 2/18
Connection
Page 2/18
Bearings
Page 2/29
Selection of bearings
Page 2/30
Diagrams of bearings
Page 2/34
Shaft extension
Page 2/27
Torque
Page 2/16
Types of construction
Page 2/25
Paint finish
Page 2/5
Frame design
Page 2/23
Rating plate
Page 2/15
Squirrel-cage motors
Technical
2
information
2/2
2/5
2/6
2/7
2/8
2/8
2/9
2/9
General information
Order number
Paint finish and packaging
Project planning aids
Standards, specifications and tolerances
Applicable standards and specifications,
national regulations, tolerances for electrical
specifications, export of low-voltage motors to
China
Energy-saving motors with European
efficiency classification in accordance with
EU/CEMEP
Motors for the North American market
Design and certification of explosion-proof
motors in accordance with directive 94/9/EC
(ATEX)
VIK design
2/18
Electrical design
Voltages, currents, and frequencies
Rated outputs and rating plates
Efficiency, power factor, and rated torque
Insulation, winding, motor protection, and
anti-condensation heating
Connection, switching, and terminal boxes
2/23
2/23
2/23
2/23
2/24
2/24
2/25
2/27
2/27
2/28
2/29
2/36
2/40
Mechanical design
Frame design
Degrees of protection
Cooling and ventilation
Coupling to gearboxes
Eyebolts
Speed and direction of rotation
Types of construction
Shaft extensions
Balance and vibration severity
Noise (mains-fed operation)
Bearings
Maximum cantilever forces
Maximum axial load
2/44
2/44
2/44
2/44
2/44
2/44
2/45
Converter-fed operation
Motor temperature detection
Insulation
Connection of the motors
Ventilation/noise
Mechanical stress, grease life
Bearings
Mechanical limit speeds
2/46
2/46
2/47
2/48
2/49
2/50
2/56
Modular technology
Rotary pulse encoder
Separately driven fan
Brakes
Dimensions and weight
2/58
2/10
2/13
2/16
2/17
Siemens M 11 2003/2004
2/1
Squirrel-cage motors
Technical information
General information
Squirrel-cage motors
Order number
1
1 M A
Explosion-proof enclosure,
EEx de IIC type of protection
1 M J
Type series
Number of poles
Design
Type of construction
Special designs
Ordering example
Three-phase motor IP55
4-pole, 50 Hz, 45 kW,
230 VB/400 V*,
IM V 5 type of construction
with canopy
Special designs:
3 PTC thermistors
Separately mounted fan
1LA5223 4AA. .
Voltage identifier
Special designs
1
9
Z
IM V 5 type of construction
with canopy
M1F
3 PTC thermistors
A11
2/2
G17
1LA5223 4AA19Z
M1F + A11 + G17
Siemens M 11 2003/2004
Order No.
9 10 11 12
Squirrel-cage motors
Technical information
General information
Order number
(continued)
Special designs
A60
Motor protection with PTC thermistors for converter-fed operation with three embedded temperature sensors for alarm in zones
Motor protection with PTC thermistors with three
embedded temperature sensors for tripping
Motor protection with PTC thermistors with six
embedded temperature sensors for alarm and
tripping
Motor protection with PTC thermistors for converter-fed operation with three embedded temperature sensors for tripping
Motor protection with PTC thermistors for converter-fed operation with six embedded temperature
sensors for alarm and tripping
Motor temperature detection with embedded
temperature sensor KTY 84-130
Motor temperature detection with embedded
temperature sensors 2 x KTY 84-130
Installation of 3 PT 100 G resistance thermometers
A61
A72
K23
2/5
K24
2/5
K26
2/5
K27
K28
2/5
L42
2/5
L43
2/5
M16
2/5
M17
2/5
M18
2/5
M19
2/5
M20
2/5
M21
2/5
M22
2/5
M23
2/5
Y54
2/5
Y53
2/5
A11
A12
A15
A16
A23
A25
C11
C12
C13
Y52
Special designs
Order code
2/17, 2/44
2/17, 2/18,
2/47
2/17
2/17
M34
2/9
M35
2/9
M38
2/9
M39
2/9
M72
M73
2/17
2/17, 2/44
G55
G56
H90
H91
H92
H93
2/17, 2/44
2/17, 2/44
2/17
Paint finish
H94
H95
2/46
2/46
2/47
2/47
2/47
2/47
2/47
2/47
E11
E21
E31
E51
E61
E71
E80
Not certified,
to ABS 50 C/CCS 45 C/RINA 45 C
temperature class F used acc. to F
Certified according to GL (Germanischer Lloyd)
Germany, CT 45 C, temperature class F used
acc. to F
Certified according to LRS (Lloyds Register of
Shipping), Great Britain, CT 45 C, temperature
class F used acc. to F
Certified according to BV (Bureau Veritas), France
CT 45 C, temperature class F used acc. to F
Certified according to DNV (Det Norske Veritas),
Norway, CT 45 C, temperature class F used acc. to F
Certified according to ABS
(American Bureau of Shipping), USA, CT 50 C,
temperature class F used acc. to F
Certified according to CCS
(Chinese Classification Society), China, CT 45 C,
temperature class F used acc. to F
Motor for use in shipping,
higher ambient temperature and/or
used as F in accordance with B
Siemens M 11 2003/2004
6/2
6/2
6/2
6/2
6/2
6/2
6/2
6/3
2/3
Squirrel-cage motors
Technical information
General information
Order number
(continued)
Special designs
Order code
Special designs
Modular technology
C00
2/50, 2/54
K10
2/19, 2/24
C01
2/50, 2/54
K11
2/24
G17
K16
G26
Mounting of brake
from 2/44,
from 2/56
from 2/50
K17
from 2/25,
2/47
2/23, 2/47
H57
from 2/47,
from 2/56
2/47, 2/48,
from 2/56
from 2/47,
from 2/56
2/48, 2/51,
from 2/56
2/49, 2/51,
from 2/56
2/48,
from 2/56
from 2/48
2/56
from 2/48
2/56
from 2/48
2/56
2/50, 2/51,
2/54
K20
K30
VIK design
2/29, 2/31,
from 2/37,
2/47
2/9, 2/47
K31
2/15, 2/47
K32
2/25
K36
2/29 2/37
K40
K45
from 2/29,
2/47
2/17
K46
2/17
K50
K83
2/18 2/22
2/29 2/35,
2/47
H58
H61
H62
H63
H64
H97
H98
H99
K82
K37
K38
2/9, 2/28
2/9, 2/28
H70
K84
H71
K85
K94
from 2/56
L03
Vibration-proof version
2/57, 2/59
L04
2/57, 2/59
L13
External earthing
2/29 2/35,
2/47
2/18, 2/47
L27
2/44
L36
L51
L52
L68
Full-key balancing
L99
Wire-lattice pallet
2/5, 2/47
M44
M46
M47
Y82
Further mountings
H72
H73
H74
H75
H78
H79
H80
Y70
2/58
2/59
2/59
Converter installation
H15
2/44, 2/46
Mechanical design
D01
2/7
D02
Coolant temperature 50 C to 40 C
2/14, 2/15
D03
Coolant temperature 40 C to 40 C
2/14, 2/15
D04
Coolant temperature 30 C to 40 C
2/14, 2/15
D30
2/8, 2/47
D31
2/8, 2/47
D40
2/8, 2/47
K01
2/27, 2/47
K06
2/20
K09
2/24
2/4
Siemens M 11 2003/2004
2/18 2/22
2/18 2/22
2/15, 2/47
Squirrel-cage motors
Technical information
General information
Paint finish
Design
Standard finish
Special finish
Short per.:
Contin.:
Short per.:
Contin.:
Also:
up to 120 C
up to 100 C
up to 140 C
up to 120 C
for aggressive atmospheres
up to 1 % acid and alkali concentration or permanent dampness in sheltered rooms
63 M
. . . . 060/063
0.65
71 M
. . . . 070
0.65
. . . . 073
80 M
. . . . 080
0.65
. . . . 083
90 S
. . . . 090
0.65
90 L
. . . . 096/097
100 L
. . . . 106/107
1.3
112 M
. . . . 113
1.5
132 S
. . . . 130/131
4.7
132 M
. . . . 133/134
160 M
. . . . 163/164
4.8
160 L
. . . . 166
180 M
. . . . 183
13.0
180 L
. . . . 186
200 L
. . . . 206/207
13.5
225 S
. . . . 220
13.7
7
225 M
. . . . 223
250 M
. . . . 253
20
280 S
. . . . 280
20
280 M
. . . . 283
315 S
. . . . 310
20
315 M
. . . . 313
315 L
. . . . 316/317/318
22
Values for type 1MJ1/1MJ8 motors on request.
Type of construction IM B 5, IM V 1
in crates
tare
kg
in cartons
tare
kg
on battens in crates
tare
tare
kg
kg
0.65
0.65
0.65
0.65
0.65
1.3
1.5
5.2
5.7
13.4
20
13.5
13.7
10
20
36
36
20
20
40
40
38
20
45
40
22
Siemens M 11 2003/2004
2/5
Squirrel-cage motors
Technical information
General information
It can be used to display operating instructions, factory test certificates, and terminal box documentations etc. as well as to
generate data sheets, dimension drawings, and start-up calculations for the corresponding
products.
Case 2
Calculation of the energy-savings as well as the amortization
time for the additional cost of
the Siemens eff1 energy-saving
motor as compared with other
known motors.
The calculation, however, requires exact knowledge about
the technical data of the motor
which is to be used for the comparison.
Case 3
Calculation of the energy-savings as well as the amortization
time for the additional cost of
the Siemens eff1 energy-saving
motor as compared with any
number of other known motors
plant analysis.
This offers an optimal basis for
making a decision when it
comes to finding the most costeffective solution. The total power factor and the total reactive
power are also indicated in this
case.
ECOFAST:
http://www.siemens.com/
ecofast
Motors:
http://www.siemens.com/
motors
Geared motors:
http://www.siemens.com/
gearedmotors
Newsletter:
http://my.ad.siemens.com/
myAnD/
2/6
Siemens M 11 2003/2004
Internet: http://www.siemens.com/energysavingprogram
Order number of the CD-ROM
04/2002 German/English:
E80001-D40-P220-X-7400
Squirrel-cage motors
Technical information
Title
IEC
IEC 60 034-1,
IEC 60 085
AC induction motors for general use with standardized dimensions and IEC 60 072
power
fixing only
Restart characteristics, rotating electrical machines
IEC 60 034-12
Terminal markings and direction of rotation, rotating electrical machines IEC 60 034-8
Designation for type of construction, installation and terminal box posi- IEC 60 034-7
tion
Entry to terminal box
DIN/EN
IEC 60 079-0
IEC 60 079-1
IEC 60 079-7
IEC 60 079-15
DIN EN 60 034-1
DIN EN 50 347
DIN EN 60 034-12
DIN EN 60 034-8
DIN EN 60 034-7
prDIN 42 925 (08/99)
DIN EN 60 034-9
DIN IEC 60 038
DIN EN 60 034-6
DIN EN 60 034-14
DIN ISO 10 816
DIN EN 60 034-5
DIN EN 50 014
DIN EN 50 018
DIN EN 50 019
DIN EN 50 021
National standards
The motors comply with the applicable IEC or European standards listed above. The European standards replace the national standards in the following
European member states:
Germany (VDE), France (NF C),
Belgium (NBNC), Great Britain
(BS), Italy (CEI), Netherlands
(NEN), Sweden (SS), Switzerland (SEV) etc.
The motors also comply with
various national standards.
Australia
(higher rated output assignment than stated
in DIN EN 50347 for frame size 250 M or
larger)
Canada
India
Norway
Electrical tolerances
The following tolerances are
permitted according to
DIN EN 60 034:
Motors which comply with
DIN EN 60034-1 must have a
voltage tolerance of 5%/frequency tolerance 2%
(Design A).
The tolerance of 5% according to DIN EN 60034-1 also applies to the rated voltage range.
If utilized, the permitted limit
temperature of the temperature
class may be exceeded by
10 K.
Efficiency for
PN 50 kW: 0.15 (1 h)
PN > 50 kW: 0.1 (1 h)
with h being a decimal number.
1 cos K
6
Minimum absolute value: 0.02
Maximum absolute value: 0.07
Power factor
Slip
Locked-rotor
current
Locked-rotor
torque
20% 1)
+20%
15% to
+25%
Breakdown torque 10%
Moment of inertia 10%
1MA motors:
Add 10 % to the certified values
for the locked-rotor current.
Factory Code:
A005216 = Works
Bad Neustadt
A010607 = Works
Mohelnice
Note:
Chinese customs checks the
need for certification of imported products by means of commodity code.
The following do not need to be
certified:
Motors imported to China
which have already been installed into a machine.
Repair parts.
2/7
Squirrel-cage motors
Technical information
Efficiency) or
(High Efficiency) in accordance with the
EU/CEMEP agreement.
2/8
Siemens M 11 2003/2004
Voltage
400 Vd/50 Hz or
460 Vd/60 Hz (50 Hz rating)
460 Vd/60 Hz (50 Hz rating)
460 Vd/60 Hz (60 Hz rating)
CSA Approval
Order Code D40 3)
The motors based on the basic
series 1LA/1LG are approved
for up to 690 V in accordance
with the Canadian regulations of
the Canadian Standard Association (CSA). Built-on or built-in
components which are used are
listed by CSA or are used by the
manufacturers in accordance
with regulations. It may have to
decided whether the motor is
suitable for the application.
The motors must be ordered
with the code D40, voltage code
"9" and the code for voltage
and frequency. The CSA sign
and the rated current (voltage
tolerance of 10%) are included
on the rating plate.
Voltage code
9 with L1U
9 with L2T
9 with L2F
Squirrel-cage motors
Technical information
Design and certification of explosion-proof motors in accordance with directive 94/9/EC (ATEX)
Zone 21 according to
IEC 61 241/EN 50 281
M34
Mains-fed operation
M38
Converter-fed operation
Zone 22 according to
IEC 61 241/EN 50 281
M35
Mains-fed operation
M39
Converter-fed operation
Mains-fed operation
M73
Converter-fed operation
The 1LA/1LG motors are suitable for use in areas with danger of dust explosions if various
precautions are taken. Surface
temperatures may not exceed
125 C during normal operation.
The version for conducting dust,
degree of protection IP65, is designed for Zone 21;
for non-conductive dust, degree of protection IP55, for
Zone 22.
The motors are fitted with an external earthing terminal and with
an external metal fan.
The PTB certificate of conformity, which is valid up to temperature class T4, covers the
following deviations: different
coolant temperature (20 C to
+60 C), site altitude, frequency and rated duty type, polechanging motors, fitting of
temperature sensors and converter-fed operation with fitting
of temperature sensors, design with explosion-proof terminal box, insulated bearing
on non-drive end. Please inquire.
Markings on the rating plate:
II 2G EEx de IIC or
II 2G EEx d II C
Type of protection EEx e II
Increased safety "e" 1)
The 1MA motors are certified
for the EEx e II type of protection for temperature classes
T1 to T3 and have an EC type
test certificate in accordance
with directive 94/9/EC (ATEX).
Higher temperature classes
are available on request.
With the exception of 2-pole
motors with frame size 225 M
or larger, all motors are standard designs i.e. the motors
are suitable for T1/T2 or T3
and can be operated with the
corresponding rated output. A
new or supplementary certificate may be needed for nonstandard designs (different
frequency, output, coolant
temperature, site altitude etc.)
(please inquire). It is essential
for the temperature class to be
specified because if not, the
standard design for T1/T2 and
T3 will be certified (double
certification fee).
Markings on the rating plate:
II 2G EEx e II T.
Take account of the rated-output classification and the dimensions of 1LA8 motors. The
terminal box cannot be rotated
by 4 x 90 for motors 1LA8,
frame sizes 355 to 357.
Siemens M 11 2003/2004
2/9
Squirrel-cage motors
Technical information
Electrical features
2/10
Siemens M 11 2003/2004
Standard voltages:
Voltages
Voltage
code
Squirrel-cage motors
Technical information
Electrical features
L1X
L1Y
Standard winding
Non-standard winding
between 200 V and 690 V
(other voltages to request)
220 Vd/380 V*
(210 230 Vd/
360 400 V*)
380 Vd/660 V*
(360 400 Vd/
625 695 V*)
415 V*
(395 435 V*)
415 Vd
(395 435 Vd)
400 Vd (460 Vd
bei 60 Hz)
(380 420 Vd)
50 Hz output
Order
Code for
50 Hz
(single
speed)
1
)
L1R
50 Hz output
L1L
56 225
56 200
180 315L
63 315L
71 200
225 315
50 Hz output
L1C
56 225
56 200
180 315M
63 315L
71 200
225 315
50 Hz output
L1D
56 225
56 200
180 315L
63 315L
71 200
225 315
50 Hz output
L1U
56 225
56 200
180 315L
Voltage at
60 Hz
Required output
at 60 Hz
1LG4,
1LG6
1LA8
1MA6,
1MA7 2)
1MJ6
1MJ7
1MJ8,
1MJ1
220 Vd/380 V*
220 Vd/380 V*
380 Vd/660 V*
380 Vd/660 V*
440 V*
440 V*
440 Vd
440 Vd
460 V*
460 V*
460 Vd
460 Vd
575 V*
575 V*
575 Vd
575 Vd
50 Hz output
60 Hz output
50 Hz output
60 Hz output
50 Hz output
60 Hz output
50 Hz output
60 Hz output
50 Hz output
60 Hz output
50 Hz output
60 Hz output
50 Hz output
60 Hz output
50 Hz output
60 Hz output
Order
Code for
60 Hz
(single
speed)
L2A
L2B
L2C
L2D
L2Q
L2W
L2R
L2X
L2S
L2E
L2T
L2F
L2U
L2L
L2V
L2M
56 225
56 225
56 225
56 225
56 225
56 225
56 225
56 225
56 225
56 225
56 225
56 225
56 225
56 225
56 225
56 225
180 315M
180 315M
180 315L
180 315L
180 315M
180 315M
180 315L
180 315L
180 315M
180 315M
180 315L
180 315L
180 315M
180 315M
180 315L
180 315L
315 450
315 450
315 450
315 450
315 450
315 450
315 450
315 450
63 315L
63 315L
63 315L
63 315L
63 315L
63 315L
63 315L
63 315L
71 200
71 200
71 200
71 200
71 200
71 200
71 200
71 200
71 200
71 200
71 200
71 200
71 200
71 200
71 200
71 200
225 315
225 280 S
225 315
225 315
225 315
225 315
225 315
225 315
225 315
225 315
225 315
225 315
225 315
225 315
225 315
225 315
315 450
315 450
315 450
315 450
315 450
315 450
315 450
315 450
Voltage at
60 Hz
Required output
at 60 Hz
1LG4
1LA8
1MA6,
1MA7 2)
1MJ6
1MJ7
1MJ8,
1MJ1
220
220
380
380
440
440
460
460
575
575
50 Hz output
60 Hz output
50 Hz output
60 Hz output
50 Hz output
60 Hz output
50 Hz output
60 Hz output
50 Hz output
60 Hz output
Order
Code for
60 Hz
(polechanging)
L4A
L4B
L4C
L4D
L4G
L4E
L4J
L4H
L4N
L4M
63 200
63 200
63 200
63 200
63 200
63 200
63 200
63 200
63 200
63 200
180 280
180 280
180 280
180 280
180 280
180 280
180 280
180 280
180 280
180 280
V
V
V
V
V
V
V
V
V
V
Required output
at 50 Hz
1LA6,
1LA9
1LG4,
1LG6
56 225
56 200
56 200
56 200
56 200
56 200
56 200
56 200
56 200
56 200
56 200
56 200
56 200
56 200
56 200
56 200
56 200
56 200
1LA8
1MA6,
1MA7 2)
1MJ6
1MJ7
1MJ8,
1MJ1
180 315M
63 315L
71 200
225 315
Siemens M 11 2003/2004
2/11
Squirrel-cage motors
Technical information
Electrical features
420 V
A
380 V
6-pole
A
420 V
380 V
8-pole
A
420 V
0.27
0.33
0.52
0.68
1.05
1.38
1.75
2.45
3.40
4.70
6.25
0.26
0.32
0.53
0.70
1.02
1.41
1.79
2.50
3.35
4.65
6.15
0.21
0.30
0.42
0.56
0.80
1.07
1.50
1.90
2.60
3.50
4.8
6.5
8.4
11.4
8.2
10.6
14.1
7.7
10.4
13.8
15.4
21.0
28.0
34.0
40
20.5
26.0
32.0
38
55
67
52
64
28.5
35
41
54
64
78
4.8
6.5
8.4
11.4
4.8
6.8
8.3
11.9
76
9.7
13.1
17.3
24.8
31
38.5
45.5
9.9
13.1
17.6
10.6
13.4
18.4
26.5
23.5
34
40
47
64
7.9
32.7
40
46.5
24.7
0.36
0.52
0.80
1.10
1.18
1.60
2.2
3.0
4.2
6.0
7.9
57
69
84
5.3
7.5
9.5
13.0
17.5
21.5
29.5
36
42
0.36
0.51
0.73
1.01
1.15
1.63
2.25
3.0
4.1
5.9
0.5
0.64
0.80
1.25
1.66
2.15
2.95
4.1
5.4
7.3
15.5
22.3
81
0.48
0.66
0.80
1.18
1.62
2.10
3.0
4.0
0.21
0.31
0.44
0.57
0.77
1.06
1.50
1.92
2.60
3.50
4.8
6.8
8.3
11.9
63
31
37
43
2/12
6.25
6.15
8.2
10.6
14.1
7.7
10.4
13.8
20.5
26.0
32.0
40
54
52
63
77
83
100
100
134
136
162
196
198
230
280
345
75
90
93
128
126
150
182
188
215
255
315
Siemens M 11 2003/2004
5.4
7.3
9.5
13.0
17.5
21.5
29.5
36
42.5
59
28.5
35
41.5
60
57
70
72
85
104
104
138
144
168
204
205
245
295
360
55
69
65
77
94
98
134
132
156
190
194
230
275
330
2.25
3.0
4.1
5.9
5.3
7.5
15.5
22.3
4.1
56
56
67
82
15.4
21.0
28.0
34.0
41.5
4.0
9.7
13.1
17.3
24.8
30.5
38.5
37
45
61
28.5
37
37
42.5
60
60
73
73
87
87
106
146
142
170
205
245
295
54
66
68
81
80
97
134
136
162
190
225
275
7.9
9.9
13.1
17.6
24.7
7.9
2.2
3.0
4.2
6.0
10.6
13.4
18.4
25.5
34.5
25
34.5
33.5
40.5
40.5
46.5
64
60
73
76
92
112
110
146
174
210
250
32
39
36.5
42
58
57
69
70
84
102
104
136
164
198
240
Squirrel-cage motors
Technical information
Electrical features
Rated currents for the rated voltage range from 380 V to 420 V at 50 Hz (continued)
Currents for voltage and number of poles
380 V
420 V
380 V
2-pole
4-pole
A
A
A
420 V
A
380 V
6-pole
A
420 V
380 V
8-pole
A
420 V
40.5
37.5
36
42.5
54
66
51
62
56
70
84
99
138
166
200
235
285
355
435
540
620
690
860
950
1080
690 1)
780 1)
880 1)
970 1)
73
90
124
146
174
210
250
305
400
495
570
630
790
880
990
640 2)
730 2)
810 2)
890 2)
30.5
37
44
81
97
134
158
192
230
275
340
34.5
40.5
54
64
76
94
128
154
184
215
265
330
450
560
640
720
880
990
1100
710 1)
810 1)
910 1)
1000 1)
425
530
590
680
820
930
1040
670 2)
750 2)
860 2)
940 2)
29
35.5
40.5
24.5
32.5
38
45
59
75
91
106
142
170
205
250
310
385
59
72
85
104
142
166
205
245
290
360
450
23
53
67
79
96
134
156
190
225
275
340
420
30.5
34.5
41
55
69
83
100
136
158
194
230
295
365
570
720
810
890
1000
1160
740 1)
830 1)
530
670
760
840
940
1060
690 2)
770 2)
480
600
680
760
850
960
1080
1200
455
560
640
720
810
910
1020
1140
The rating plates of 1MJ6 motors specify the maximum current in the voltage range in addition to the rated current.
This maximum is approx. 5% higher than the rated current.
Maximum output at 60 Hz
for voltages between 220 V
or 380 V and 725 V
2-pole
4-pole
6-pole
kW
kW
kW
Motor type
8-pole
kW
1LA6 106
1LA6 107
1LA6 113
1LA6 130
1LA6 131
1LA6 133
1LA6 134
1LA6 163
1LA6 164
1MJ6 070
1MJ6 073
1MJ6 080
1MJ6 083
1MJ6 096
1MJ6 097
1MJ6 106
1MJ6 107
1MJ6 113
1MJ6 130
1MJ6 131
1MJ6 133
1MJ6 134
1MJ6 163
1MJ6 164
0.105
0.14
0.21
0.29
0.43
0.63
0.86
1.3
1.75
2.55
3.45
0.07
0.105
0.14
0.21
0.29
0.43
0.63
0.86
1.3
1.75
2.55
3.45
4.6
6.3
4.6
6.3
8.6
12.6
17.3
8.6
12.6
8-pole
kW
Maximum output at 60 Hz
for voltages between 220 V
or 380 V and 725 V
2-pole
4-pole
6-pole
kW
kW
kW
0.1
0.21
0.29
0.43
0.63
0.86
1.3
1.75
2.55
3.45
4.6
6.3
8.6
0.1
0.14
0.21
0.29
0.43
0.63
0.86
1.3
1.75
2.55
3.45
4.6
6.3
1LA7 166
1LA5 183
1LA5 186
1LA5 206
1LA5 207
1LA5 220
1LA5 223
1LA6 166
1LG . 183
1LG . 186
1LG . 188
1LG . 206
1LG . 207
1LG . 208
1LG . 220
1LG . 223
1LG . 228
1LG . 253
1LG . 258
1LG . 280
1LG . 283
1LG . 288
1LG . 310
1LG . 313
1LG . 316
1LG . 317
1LG . 318
1MJ6 166
1MJ6 183
1MJ6 186
1MJ6 206
1MJ6 207
1MJ7 220
1MJ7 223
1MJ7 253
1MJ7 280
1MJ7 283
1MJ7 310
1MJ7 313
21.3
24.5
17.3
21.3
25.3
34.5
33.5
33.5
41.5
51
51
62
62
84
84
101
123
123
148
180
224
12.6
18
22
22
26.5
36
34.5
42.5
42.5
52
63
63
86
86
104
127
127
152
184
230
8.6
36
44.5
44.5
54
54
66
90
90
108
132
158
192
13.2
18
18
22
22
26.5
36
36
44.5
44.5
54
66
66
90
108
132
158
1) Current at 690 V.
2) Current at 725 V.
Siemens M 11 2003/2004
2/13
Squirrel-cage motors
Technical information
Electrical features
Motor type
Maximum output at 60 Hz
for voltages between 220 V
or 380 V and 725 V
2-pole
4-pole
6-pole
kW
kW
kW
8-pole
kW
280
353
398
448
560
616
693
781
184
230
288
362
408
460
518
575
644
725
8-pole
kW
Maximum output at 60 Hz
for voltages between 220 V
or 380 V and 725 V
2-pole
4-pole
6-pole
kW
kW
kW
288
362
408
460
575
644
725
817
920
1040
1150
230
288
362
460
518
575
644
725
817
920
1MJ1 353
1MJ1 355
1MJ1 357
1MJ1 403
1MJ1 405
1MJ1 407
1MJ1 453
1MJ1 455
1MJ1 457
1MJ1 458
190
240
280
350
1MJ8 313
1MJ8 314
1MJ8 316
1MJ8 353
1MJ8 354
1MJ8 356
1MJ8 357
400
450
500
560
630
on request
Size
Number of poles
56 to 160
180 to 315
2 to 8
2
4
6 and 8
180
220
250
280
315
355
400
450
500
560
630
710
800
900 1)
1000 1)
132
145
175
225
280
On request
100
120
145
180
225
On request
Horizontal motor
50 Hz with foot
V
V
V
V
V
60 Hz with foot
V
V
V
V
50 Hz with flange
V
2/14
Siemens M 11 2003/2004
60 Hz with flange
V
Altitude above
sea level ASL
in m
1000
1500
2000
2500
3000
3500
4000
Vertical motor
50 Hz
V
V
V
V
V
60 Hz
V
On request
V
Coolant temperature in C
<30
1.07
1.04
1.00
0.96
0.92
0.88
0.82
30 40
1.00
0.97
0.94
0.90
0.86
0.82
0.77
45
0.96
0.93
0.90
0.86
0.82
0.79
0.74
50
0.92
0.89
0.86
0.83
0.79
0.75
0.71
55
0.87
0.84
0.82
0.78
0.75
0.71
0.67
60
0.82
0.79
0.77
0.74
0.70
0.67
0.63
The coolant temperature and the altitude are rounded to the nearest
5 C or 500 m.
Squirrel-cage motors
Technical information
Electrical features
above 40 C in compliance
with rated output.
When used acc. to class B with
higher ambient temperatures/
greater site altitude, the power
is reduced according to the table at the bottom of Page 2/13.
Ambient temperature
All motors with the standard design can be used at ambient
temperatures of -20 C to
+40 C.
Size
1LA7
1LA6
1LG4
56M 160L
100L 160L
180M 225M
250M 315L
180M 225M
250M 315L
1LG6
Ambient
temperature C
30 to +55
30 to +55
30 to +55
20 to +55
30 to +55
20 to +55
Rating plate
1LA5
1LA7
1LA9
1LA6
1LA6
1LG4
1LG6
1LA8
1MA7
1MA6
1MA6
1MJ6
1MJ7
1MJ8
1MJ1
all
all
all
all
100 to 160
all
all
all
all
180 to 200
from 225
71 to 200
225 to 315
all
all
C
C
C
C
C
C
C
V
V
V
V
V
C
C
V
V
V
V
C
C
C
V s
V
s
s
V V s
s s s
s s s
34,0-32,0/19,6-18,5 A
50-Hz-data
Size
Type of
construction
Date of manufacture
YY MM
33,5-31,0 A
60-Hz-data
Degree of protection
M1-5219b
D-91056 Erlangen
3 ~ M
E 0 1
1 2 0
g e n
E r la n
0 V
0 5 6
0 /6 9
D -9 1
z 4 0 1 ,5 /1 8
H
0
5
3
W
k
2 9 4 0
1 8 ,5
0 ,9 2
c o s j -7 2 5 V
0
A
6 6
-1 7 ,6
4 2 0 /
3 8 0 - 0 ,5 /1 9 ,6
-3
3 4 ,0
,2
/m
6 0
2 K A
C
1 6 6 B 4 0
1 L A 9
6 0 0 3 4
C /E N .C l.F A M
E
I
.
t
2
o
V
0 0
T h
1
0
5
0
6
5
4
1
P
A
Z
1 1 0
L I
2 7 ,7
6 0 H
0 7 /4 7 B 3 1 6 0
P
K W
k g IM
1 8 ,5
5 5 0 R
,9 2 3 F F 9
0
F
P
/
M .E
O
N
A
D E
A
N E M
A C O
5
IG N
D E S
in
F 1 ,1
-1 2 S
M G 1
M
P
2 5 ,0 H
1 ,0 %
0 3 2 A
J C C
T
C O N
Z
A 6 0 6 -4 A
6 1 8
4 0 C
1 L G
.
t
A M B
o
1
5 5 0
3 ~ M
.C l.F
5 T h
1 2 4 1
5
0
/
P
V
I
2
2 0
4 6 0
A
U C 0
0 L
3 6 ,5
e n
3 1 8
la n g
B
r
Z
E
P M
H
M
I
6 0
7 5 R
k g
0 5 6
7
1
0
1
9
8
W
1
D
2 2 K 8 3
0 ,0 H P
,
,4 % 3
P F 0
F F 9 2
V /
A
O M .E
6 9 0
2
/
N
A
3
0
0
A
4
0
4
/2
C C
N E M
4 0 ,5 /m in
O D E K
z
N A C
N T
5 0 H
1 4 7 0
D E S IG
5 C O
W
S F 1 ,1
/
2
4
2 2 k
1
8
V
,
1
0
M G
7 2 5
0
oc s j
6
A
4 2 0 /6
2 3 ,5
3 8 0 H
2 4 ,5 4 0 ,5 /
4 2 ,5 4
3
0
A60
6 0
C
N
2
E
/
6
4
IE C
616
6003
0158
1MJ 3 IEC/EN
l.F
Th.C
ot.
3 00
55
3~M 71101 1
IP
L
0
7/4
3 16 IK
E010
IM B
V
0 kg
gen 16
2 G
n
a
II
rl
/
E
x
6
5
V
0
C T4
/690
D-91
de II
A
z 400
A
EEx
/18,8
50 H
9,6
32,5 0/min
/1
W
,0
k
34
18,5 0,91 294
,0
N 7
/
/I
j
s
IA
o
c
V
-725
/660
0
2
1093
380-4
TEX
01 A
PTB
2 1 8 b
M 1 -5
C Standard design
V with no extra charge
s with extra charge
Siemens M 11 2003/2004
2 2 0 a
M 1 -5
Rating plate
217a
M1-5
Motor Size
type
2/15
Squirrel-cage motors
Technical information
Electrical features
Part-load efficiency % at
1/4
1/2
3/4
of full load
93
96
97
92
95
96
90
93.5
95
89
92.5
94
88
91.5
93
87
91
92
86
90
91
85
89
90
84
88
89
80
87
88
79
86
87
78
85
86
76
84
85
74
83
84
72
82
83
70
81
82
68
80
81
66
79
80
64
77
79.5
62
75.5
78.5
60
74
77.5
58
73
76
56
72
75
55
71
74
54
70
73
53
68
72
52
67
71
51
66
70
50
65
69
49
64
67.5
48
62
66.5
47
61
65
46
60
64
45
59
63
44
57
62
43
56
60.5
42
55
59.5
41
54
58.5
Rated torque
The rated torque in Nm delivered at the motor shaft is
M
9.55 P 1000
n
P Rated output in kW
n Speed in rpm
If the voltage deviates from its
nominal value within the allowed limits, the locked-rotor
torque, the pull-up torque, and
the breakdown torque vary
with the approximate square
of the value, while the lockedrotor current varies approximately linearly.
2/16
Siemens M 11 2003/2004
4/4
5/4
97
96
95
94
93
92
91
90
89
88
87
86
85
84
83
82
81
80
79
78
77
76
75
74
73
72
71
70
69
68
67
66
65
64
63
62
61
60
96.5
95.5
94.5
93.5
92.5
91.5
90
89
88
87
86
85
83.5
82.5
81.5
80.5
79.5
78.5
77.5
76.5
75
74
73
72
71
70
69
68
67
66
65
64
63
62
61
60.5
59.5
58.5
4/4
5/4
0.92
0.91
0.90
0.89
0.88
0.87
0.86
0.85
0.84
0.83
0.82
0.81
0.80
0.79
0.78
0.77
0.76
0.75
0.74
0.73
0.72
0.71
0.92
0.91
0.90
0.89
0.88
0.87
0.86
0.86
0.85
0.84
0.83
0.82
0.81
0.80
0.80
0.79
0.78
0.78
0.77
0.77
0.76
0.76
Squirrel-cage motors
Technical information
Electrical features
For motors
1LA5,
1LA6,
1LA7,
1LA9
1LG4, 1LG6
1MJ6,
1MJ7/1MA6
1LA8
1MJ8
1MJ1
1LG4/1LG6
in (E)Ex nA
Size
56 to 80
90 to 112
132 to 200
225
180 and 200
225 and 250
280 and 315
all
315
355
355
400
450
180 and 200
225 and 250
280 and 315
Anti-condensation heating
Supply voltage 230 V
Order Code K45
Supply voltage 115 V
Order Code K46
Anti-condensation heaters can
be fitted to motors whose windings are exposed to a risk of
condensation due to the ambient climate, e.g. stationary motors in a damp environment or
motors subjected to considerable fluctuations in temperature.
Siemens M 11 2003/2004
2/17
Squirrel-cage motors
Technical information
Electrical features
2/18
Mains conductors
The mains conductors must
be dimensioned in accordance with DIN VDE 0298.
The number of required possibly parallel feeders is determined by
the maximum connectable
conductor cross-section,
Type gk030
Siemens M 11 2003/2004
Squirrel-cage motors
Technical information
Electrical features
Type gk465
1LA5, 1LA9
1LA6
1LG4, 1LG6
1LA8
180 to 225
100 to 160
180 to 200
225
250 to 315
315 and 355 1)
400 and 450
Feeder connection
Without cable lug or with cable
lug
Cast iron
4 holes, sealed
Retrofitting
possible
Retrofitting
possible
80 to 90
100 to 160
5)
180 to 225
1LA6
100 to 160
1LG4, 1LG6
180 to 315
4)
1LA8
315
355
400 and 450
V
V
V
V 1)
V 1)
V 1)
V
V
V
V
V
V
V Available design
1) Rotated by 15.
2) The position of the cable entry
must be specified when ordering.
Siemens M 11 2003/2004
2/19
Squirrel-cage motors
Technical information
Electrical features
Terminal screw
thread
Max. conductor
size
Sealing range in
accordance with
DIN 46319
Cable entry
1 3
))
Split plate 2)
Max. outer cable
diameter
M4
mm2
2.5
mm
9 17
4.5 10
Size
M25 x 1.5
M16 x 1.5
mm
M4
11 21
M32 x 1.5
M4
M5
6
16
11 21
19 28
M32 x 1.5
M40 x 1.5
M6
M8
25
35
27 35
27 35
M50 x 1.5
M50 x 1.5
gk 330
gk 430
gt 431
gt 520
6
6
6
6
M5
M6
M8
M10
16
25
35
120
19 28
27 35
27 35
32 42
M40 x 1.5
M50 x 1.5
M50 x 1.5
M63 x 1.5
40 50
gt 620
M12
240
40 48
M63 x 1.5
40 60
gt 640
1XB1 621
6
6
M12
M16
240
400
40 48
41 56
M63 x 1.5
2 x M72 x 2/
2 x M25 x 1.5
40 60
40 70
400
450
1XB1 631
12
M16
400
4 x 80/
2 x M25 x 1.5
40 75
2/20
Siemens M 11 2003/2004
Feeder connection
Without cable lug 4) or
with cable lug
4) The parts required for the connection without cable lugs are supplied in an accessories pack with
the terminal box for all motors with
frame size 225 or larger.
Squirrel-cage motors
Technical information
Electrical features
1LA7 in (E)Ex n
80 to 90
V
V
2
Rotation of terminal box
90 1)
180 1)
V
Retrofitting
possible
100 to 160
V 2)
100 to 160
180 to 225
1MJ6
250 to 315
71 to 200
V
V
V
V
V
V
V
V
1MJ7
225 to 315
1MJ8
315 to 355
1MJ1
355 to 450
Sealing range
Cable entry 3)
Split plate
Maximum outside
cable diameter
mm
11 16
59
Size
M25 x 1.5
M16 x 1.5
mm
14 21
M32 x 1.5
19 27
19 27
24 35
M40 x 1.5
M40 x 1.5
M50 x 1.5
32 42
M63 x 1.5
40 48
M63 x 1.5
1MA6 and
1LA6 in (E)Ex n
V Available design
Terminal boxes for 1MA6, 1MA7 motors and 1LA6/7/9 motors in (E)Ex n-design and Zone 21
Size
Type
Number of
Terminal screw
Max. conductor
terminals
thread
size
1LA6
1MA7
1MA6
1LA7
1LA9
mm2
63
gk 130
6
M4
4
71
80
90
100
gk 135
112
132
gk 230
gk 235
6
M4
6
160
gk 330
gk 335
6
M5
16
180
1XB7 222 1XB7 222 6
M6
10
200
1XB7 322 1XB7 322 6
M8
50
225
250
1XB7 422 6
M10
120
280
315
1XB7 522 6
M12
240
gt 351
gt 451
6
6
M6
M8
10
50
19 27
24 35
M40 x 1.5
M50 x 1.5
gt 540
M10
120
32 42
M63 x 1.5
gt 640
M12
240
40 48
M63 x 1.5
gt 640
1XB1 621
6
6
M12
M16
240
240
40 48
41 56
M63 x 1.5
2 x M72 x 2/
2 x M25 x 1.5
40 60
40 70
400
1XB1 631
12
M16
240
4 x 80/
2 x M25 x 1.5
40 75
450
2/21
Squirrel-cage motors
Technical information
Electrical features
71
80
90
100
112
132
160
180
200
225
250
280
315
Terminal screw
thread
Feeder connection
Without cable lug or with cable
lug 1)
Aluminum alloy
Cast iron
Welded steel
Sealing range
Cable entry 3)
mm2
4
mm
11 16
Size
M25 x 1.5
M25 x 1.5
M32 x 1.5
M32 x 1.5
gk 330
M4
gk 420
M4
gk 420
M4
11 16
14 21
14 21
gk 465 V
1XC1 270
1XC1 380
6
6
M5 V
M6
M8
16 V
25
50
19 27
19 27
24 35
M40 x 1.5
M40 x 1.5
M50 x 1.5
1XC1 480
M10
120
32 42
M63 x 1.5
1XC1 580
M12
240
40 48
M63 x 1.5
M12
M16
120 to 300
37 44 2)
35 75 2)
M63 x 1.5 2)
315
355
6
6
Available soon
Explosion-proof terminal boxes can be fitted (to order), except for frame sizes 180 and
200.
Unused holes for 1MJ motors
must be sealed in accordance
with EN 50 014.
1) The parts for the connection without cable lugs are supplied in an
accessories pack with the terminal box for all 1MJ7 motors with
frame size 225 M or larger.
2/22
Siemens M 11 2003/2004
Squirrel-cage motors
Technical information
Mechanical design
Frame design
Some foot-mounting motors
have two fixing holes at the nondrive end (see dimensions
table).
Degrees of protection
All motors are designed for
IP55.
They are suitable for use in
dusty or damp surroundings.
The motors can be used in the
tropics. Approx. value 60% relative humidity at CT 40 C. Other
requirements on request.
All motors which have a shaft
extension pointing upwards
must have a means (provided
by the user) of preventing the
ingress of liquids along the
shaft.
Materials
Type series
Size
Fan material 1)
1LA5, 1LA7
1LA9
1LA6
1MA7
1MA6
1MJ6
1MJ7
1LA8
1LG4, 1LG6 2)
63 to 225
63 to 200
100 to 160
63 to 160
100 to 315
71 to 200
255 to 315
315 to 450
180 to 315
Plastic
1MJ8
1MJ1
315 to 355
355 to 450
Plastic
Glass-reinforced
plastic
Coupling to gearboxes
The flange-mounting motors
can be fitted with a radial seal
for coupling to gearboxes.
Order Code K17.
2/23
Squirrel-cage motors
Technical information
Mechanical design
Eyebolts
The 1LA7, 1MA7 and 1LA5 horizontally mounted motors from
frame size 100 L or larger have
two cast eyebolts. Vertically
mounted motors are additionally supplied with two repositionable eyebolts.
The 1LA6, 1MA6 horizontal footmounting motors are supplied
with one eyebolt.
Frame sizes 100 to 160 are supplied with horizontal flangemounting types with one eyebolt. One repositionable eyebolt
is additionally supplied for vertically mounted motors. For frame
sizes 180 M to 315 L, all flangemounting types are supplied
with two diagonal eyebolts.
They can also be used for vertically mounted motors.
Type series
1LA5, 1LA7,
1LA9
1MA7
1LG4, 1LG6
1LA6, 1MA6
1MJ6
1LA8
1MJ8
1MJ1
Size
56 to 100 2)
112 to 225
63 to 100 2)
112 to 160
180 M to 315 L
100 to 200
225 to 315 M
315 L
71 and 80
90 to 160
180 to 315
315 to 450
315 to 355
355 to 450
Frame material
Aluminum alloy
Aluminum alloy
Aluminum alloy
Aluminum alloy
Cast iron
Cast iron
Cast iron
Cast iron
Cast iron
Cast iron
Cast iron
Cast iron
Welded steel
Frame feet
cast
bolted
cast
bolted
cast 3)
bolted
cast
bolted
cast
bolted
bolted
cast
welded
2/24
Siemens M 11 2003/2004
Squirrel-cage motors
Technical information
Mechanical design
Size
Code
Order Code
12th position
IM B3
IM B 6/IM 1051,
IM B 7/IM1061,
IM B 8/IM1071
IM V 5/IM1011
without canopy
IM V 6/IM 1031
IM V 5/IM 1011
with canopy
56 M to 450
0 4)
56 M to 315 L
56 M to 315 M
315 L
0
9 1)
M1D
56 M to 315 M
315 L
0
9 1)
M1E
63 M to 315 L
9 1) 7)
M1F
56 M to 315 M
1 2)
56 M to 315 M
315 L to 450
1 2) 3)
8 4)5)1)
63 M to 450
4 1)2)3)5)7)
56 M to 160 L
180 M to 315 M
1
9 2) 3)
M1G
56 M to 450
6 4)
Flange
IM B 5/IM 3001
IM V 1/IM 3011
without canopy
IM V 1/IM 3011
with canopy
IM V 3/IM 3031
IM B 35/IM 2001 6)
The flanges are assigned to the frame sizes as FF with through-holes in DIN EN 50 347.
A-flanges acc. to DIN 42 948 are still valid.
Siemens M 11 2003/2004
2/25
Squirrel-cage motors
Technical information
Mechanical design
Size
Code
Order Code
12th position
Standard flange
IM B 14/IM 3601,
IM V 19/IM 3631,
IM V 18/IM 3611
without canopy
IM V 18/IM 3611
with canopy
IM B 34/IM 2101
56 M to 160 L
2 2)
63 M to 160 L
9 1) 2)
M2A
56 M to 160 L
7 2)
56 M to 160 L
3 3)
63 M to 160 L
9 1) 3)
M2B
56 M to 160 L
9 3)
M2C
Custom flange
IM B 14/IM 3601,
IM V 19/IM 3631,
IM V 18/IM 3611
without canopy
IM V 18/IM 3611
with canopy
IM B 34/IM 2101
The standard flanges are assigned to the frame sizes as FT with threaded holes in DIN EN 50 347.
C-flanges acc. to DIN 42 948 are still valid.
The custom flange was assigned as large flange in the previous DIN 42 677.
All types of construction within the following series have equal dimensions:
IM B3, IM B6, IM B7, IM B8, IM V5, and IM V6
IM B5, IM V1, and IM V3
IM B14, IM V18, and IM V19
The motors in the standard power range are available in the standard types of construction IM B3, IM B5 or IM B14, and can be operated
in mounting positions IM B6, IM B7, IM B8, IM V5, IM V6, IM V1, IM V3 (up to frame size 160 L) or IM V18 and IM V19. Eyebolts are available
for transport and installation in a horizontal position. In conjunction with the eyebolts, for the purpose of stabilizing the position when the
motor is arranged vertically, additional lifting straps (DIN EN 1492-1) and/or clamping bands (DIN EN 12195-2) must be used. If mounting
position IM V1 is ordered, eyebolts are supplied for vertical mounting.
On the normal rating plate, therefore, they are marked with only the basic type of construction.
If foot-type motors larger than frame size 180 M are mounted to the wall, it is recommended
that especially the motor feet are supported.
For all motors with the shaft end pointing downwards,
the version "with canopy" is recommended;
see Section "Technical Information", "Degrees of protection".
For explosion-proof motors:
For types of construction with shaft end pointing downwards,
the version "with canopy" is mandatory.
Types of construction with shaft end pointing upwards must be
suitably covered in order to avoid that small parts
fall into the fan cowl.
(See also Section 17 DIN EN 50 014).
The cooling may not be impaired by the cover.
2/26
Siemens M 11 2003/2004
Squirrel-cage motors
Technical information
Mechanical design
Shaft extensions
60 centre hole to DIN 332,
Part 2.
Thread
mm
DR M3
DR M4
DR M5
DR M6
DR M8
DR M10
DR M12
DS M16
DS M20
DS M24
H > 400
Rigid installation
H > 400
3.5
2.8
2.8
2.8
1.8
1.8
Precision-balanced designs
of pole-changing motors are
available in accordance with
DIN EN 60 034-14.
Siemens M 11 2003/2004
2/27
Squirrel-cage motors
Technical information
Mechanical design
A-weighted measuring-surface sound pressure level and sound power level at rated power
Standard design
Type series Size
Measuring-surface sound pressure level (LpfA)
Sound power level (LWA)
2-pole
4-pole
6-pole
8-pole
LpfA
LpfA
LpfA
LpfA
LWA
LWA
LWA
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
1LA5,
56
41
52
42
53
38
49
1LA6,
63
49
60
42
53
39
50
1LA7,
71
52
63
44
55
39
50
36
1LA9,
80
56
67
47
58
40
51
41
1MA7,
90
60
72
48
60
43
55
41
1MA6,
100
62
74
53
65
47
59
45
1MJ6,
112
63
75
53
65
52
64
49
1MJ7
132
68
80
62
74
63
75
53
160
70
82
66
78
66
78
63
180
70
83
63
76
66
78
60
200
71
84
65
78
66
78
58
225
71
84
65
78
59
72
58
250
75
89
65
79
60
74
57
280
77
91
67
81
60
74
58
315
79
93
69
83
63
77
62
1LG4
180
69
82
65
78
59
72
67
200
73
86
66
79
59
72
57
225
73
86
66
79
60
73
61
250
75
88
67
80
61
74
55
280
74
87
70
83
61
74
58
315
79
92
70
83
65
78
64
1LG6
180
67
80
60
73
56
69
66
200
71
84
62
75
59
72
66
225
71
84
60
73
59
72
58
250
71
84
65
78
60
73
57
280
73
86
67
80
58
71
58
315
76
89
68
81
61
74
64
1LG4
180
71
84
65
78
59
72
67
increased
200
73
86
66
79
61
74
57
power
225
73
86
66
79
60
73
61
250
75
88
67
80
61
74
55
280
74
87
70
83
61
74
58
315
65
78
64
1LA8
315
82
97
73
87
68
82
65
1
1
355
77 )
92 )
75
90
71
86
67
1
1
400
78
93
73
88
69
79 )
94 )
1
1
450
81
96
75
90
71
81 )
96 )
1MJ8
315
80
94
70
84
70
84
69
355
82
97
73
88
75
90
73
1MJ1
355
78
94
76
92
74
90
75
400
80
96
78
94
75
91
77
450
82
99
80
97
77
94
79
Low-noise design
Type series
Size
1LA5, 1LA6,
1LA7,1MA7,
1MA6, 1MJ6,
1MJ7
Anticlockwise rotation
Order Code K38
1LG4, 1LG6 2)
1LA8
1MJ8
1) The standard motors have an axial-flow fan for clockwise rotation.
Order Code K37 is not needed.
For anticlockwise rotation please
state Order Code K38.
2) Not required for 1LG6 motors because these motors are already
noise optimized.
2/28
Siemens M 11 2003/2004
1MJ1
132
160
180
200
225
250
280
315
180
200
225
250
280
315
315
315
355
355
400
450
2-pole motors
LpfA
dB(A)
64
64
63
63
68
70
72
74
65
70
68
70
72
74
75
68
69
Available soon
LWA
dB(A)
76
76
76
76
80
82
84
86
78
83
81
83
85
87
90
82
84
LWA
dB(A)
47
52
53
57
61
65
75
73
71
71
71
72
76
80
70
74
68
71
77
79
79
71
70
71
77
80
70
74
68
71
77
79
82
84
86
83
88
91
93
96
Squirrel-cage motors
Technical information
Mechanical design
Bearings
Bearing life (nominal rated
life)
The nominal bearing life is
specified by standard calculation methods (DIN ISO 281) and
is achieved or exceeded by
90 % of bearings when operated in accordance with catalog
specifications.
If the operating conditions are
below average, a bearing life of
100,000 (Lh10) hours can be
achieved.
The bearing life essentially depends on the size of the bearing, the load, the operating conditions, the speed, and the relubrication interval.
Bearing system
The nominal bearing life of motors with horizontal type of construction is at least 40,000 hours
if there is no additional axial
loading at the output coupling;
with the maximum permitted
loads it is at least 20,000 hours.
This is provided that the motor is
operated at 50 Hz. The nominal
bearing life is reduced for converter-fed operation with higher
frequencies.
In the basic design of the bearings system, the floating bearing is at the drive end (DE) and
the located bearing (axially
fixed from frame size 160) at the
non-drive end (NDE). The located bearings can also be fitted to
the drive end (DE) on request,
(Fig. 3 Page 2/34).
Order Code K94
Regreasable
The bearing life of regreasable
motors can be increased by observing specified relubrication
intervals; this can also compensate for other factors such as
temperatures, ingress of liquids, speed, bearing size, and
mechanical load.
Prelubricated
For prelubricated bearings, the
grease life is tailored to the
bearing life. However, the motor
must be operated according to
catalogue specifications.
Standard motors with a frame
size of up to and including 250
are prelubricated.
Grease life
up to CT 40 C 2)
20,000 h or 40,000 h 3)
Regreasing interval
up to CT 40 C 2)
8000 h
8000 h
4000 h
6000 h
3000 h
6000 h
8000 h
4000 h
8000 h
3000 h
6000 h
8000 h
8000 h
4000 h
8000 h
3000 h
6000 h
2000 h
4000 h
4000 h
8000 h
3000 h
6000 h
3) 40,000 h applies to clutch abrasion for horizontally installed motors without additional axial loads.
Siemens M 11 2003/2004
2/29
Squirrel-cage motors
Technical information
Mechanical design
Bearings (continued)
Selection of bearings for 1LA, 1LG, and 1MA motors, basic design
For motors
Frame size
Type
1LA5 . . .
1LA6 . . .
1LA7 . . .
1LA9 . . .
1MA6 . . .
1MA7 . . .
Number of poles
Drive-end bearing
56 M
. . . . 05 .
all
Horizontal motors
6201 2ZC3
63 M
71 M
80 M
90 S/L
100 L
112 M
132 S/M
160 M/L
....
....
....
....
....
....
....
....
06 .
07 .
08 .
09 .
10 .
113
13 .
16 .
all
all
all
all
all
all
all
all
6201 2ZC3
6202 2ZC3
6004 2ZC3
6205 2ZC3
6206 2ZC3 1)
6206 2ZC3 1)
6208 2ZC3 1)
6209 2ZC3 1)
6201 2ZC3
6202 2ZC3
6004 2ZC3
6004 2ZC3
6205 2ZC3 1)
6205 2ZC3 1)
6208 2ZC3 1)
6209 2ZC3 1)
180 M/L
. . . . 18 .
all
6210 ZC3 1)
6210 ZC3 1)
200 L
225 S/M
250 M
280 S
280 M
....
....
....
....
all
all
all
2
4 to 8
6212 ZC3 1)
6213 ZC3 1)
6215 ZC3 1)
6216 C3
6317 C3
6212 ZC3 1)
6212 ZC3 1)
6215 ZC3 1)
6216 C3
6317 C3
315 S
315 M
315 L
. . . . 310
. . . . 313
. . . . 316
. . . . 317
. . . . 318
1LG4 . . .
1LG6 . . .
. . . . 18 .
2
4 to 8
2
4 to 8
6217 C3
6319 C3
6217 C3
6319 C3
6217 C3
6319 C3
6217 C3
6319 C3
20 .
22 .
253
28 .
Vertical motors
6217 C3 3)
6319 C3
Horizontal motors
6201 2ZC3
all
6210ZC3 2)
6210ZC3 2)
200 L
225 S
225 M
250 M
280 S
280 M
315 S
315 M
. . . . 20 .
. . . . 22 .
all
all
6212ZC3 2)
6213ZC3 2)
6212ZC3 2)
6213ZC3 2)
. . . . 25 .
. . . . 28 .
all
2
4 to 8
2
4 to 8
6215ZC3 2)
6217 C3
6317 C3
6219 C3
6319 C3
6215ZC3 2)
6217 C3
6317 C3
6219 C3
6319 C3
315 L
. . . . 316
. . . . 317
. . . . 318
1LA8 . . .
. . . . 31 .
. . . . 35 .
. . . . 35 .
. . . . 40 .
. . . . 40 .
. . . . 45 .
. . . . 45 .
2
4 to 8
6219 C3
6319 C3
6219 C3
6319 C3
2 to 8
2
4 to 8
2
4 to 8
2
4 to 8
6218 C3
6218 C3
6220 C3
6218 C3
6224 C3
6220 C3
6226 C3
180 M/L
315
355
400
450
. . . . 310
. . . . 313
2/30
3) Only at 50 Hz.
Siemens M 11 2003/2004
Fig. No.
on
pages
2/34 and
2/35
Non-drive end
bearing
7218 B + 6218 C3
7220 B + 6220 C3
7218 B + 6218 C3
7224 B + 6224 C3
7220 B + 6220 C3
7226 B + 6226 C3
6218 C3
6218 C3
6220 C3
6218 C3
6224 C3
6220 C3
6226 C3
Vertical motors
Fig.1
Fig. 2
Fig. 4
Fig. 5
7217 B 3)
6319 C3
Fig. 4
Fig. 5
7219 BEP
Fig. 5
Fig. 6
and
Fig. 7
Squirrel-cage motors
Technical information
Mechanical design
Bearings (continued)
Type
Number of poles
Drive-end bearing
Non-drive end
bearing
71 M
1MJ6 07 .
all
Horizontal motors
6202 ZC3
80 M
90 L
1MJ6 08 .
1MJ6 09 .
all
all
6004 ZC3
6205 C3
6004 ZC3
6205 C3
Fig. 9
100 L
112 M
132 S
132 M
1MJ6 10 .
1MJ6 11 .
1MJ6 13 .
all
all
all
6206 C3
6306 C3
6308 C3
6206 C3
6306 C3
6308 C3
Fig. 10
160 M
160 L
180 M
180 L
1MJ6 16 .
all
6309 C3
6309 C3
1MJ6 18 .
all
6210 C3
6210 C3
200 L
225 S
225 M
250 M
280 S
280 M
1MJ6 20 .
1MJ7 22 .
all
all
6212 C3
6213 C3
6212 C3
6213 C3
1MJ7 253
1MJ7 28 .
all
all
6215 C3
NU 216
6215 C3
6216 C3
315 S
315 M
315
1MJ7 31 .
2
4 to 8
2
4 to 8
NU 217
NU 218
6316 C3
6320 C3
6217 C3
6218 C3
6316 C3
6320 C3
6316 C3
6320 C3
355
1MJ8 35 .
355
1MJ1 35 .
400
1MJ1 40 .
450
1MJ1 45 .
2
4 to 8
2
4 to 8
2
4 to 8
2
4 to 8
6316 C3
6320 C3
6316 C4
6320 C3
6317 C4
6322 C3
6318 C4
6324 C3
6316 C3
6320 C3
6316 C4
6320 C3
6317 C4
6322 C3
6318 C4
6324 C3
6316 C3
6320 C3
7316 B
7320 B
7317 B
7322 B
7318 B
7324 B
1MJ8 31 .
Vertical motors
Fig. No.
on
page
2/35
Fig. 8
Fig. 11
Fig. 12
Siemens M 11 2003/2004
Fig. 13
No figure
2/31
Squirrel-cage motors
Technical information
Mechanical design
Bearings (continued)
Selection of bearings for 1LA, 1MA, and 1MJ motors, bearings for high cantilever forces, Order Code K20
Please enquire about 1MJ8 and 1MJ1 motors
For motors
Type
Number of poles
Frame size
1LA5 . . .
1LA6 . . .
1LA7 . . .
1LA9 . . .
1MA6 . . .
1MA7 . . .
100
112
132
160
180
200
225
250
280
....
....
....
....
....
....
....
....
....
315 S
315 M
315 L
. . . . 310
. . . . 313
. . . . 316
. . . . 317
. . . . 318
1LA8 . . .
. . . . 31 .
. . . . 35 .
1MJ6 . . .
. . . . 18 .
. . . . 20 .
1MJ7 . . .
. . . . 22 .
. . . . 253
315
355
180
200
225
250
10 .
11 .
13 .
16 .
18 .
20 .
22 .
253
28 .
2/32
Drive-end bearing
Non-drive end
bearing
Horizontal motors
6306 ZC3
6306 ZC3
6308 ZC3
6309 ZC3
6310 ZC3
6312 ZC3
NU 213 E 3) (6313 ZC3) 2)
NU 215 E 3)
NU 216 E
NU 317 E 3)
NU 217 E 3)
NU 319 E 3)
NU 217 E 3)
NU 319 E 3)
Vertical motors
all
all
all
all
all
all
all
all
2
4 to 8
2
4 to 8
2
4 to 8
Vertical motors
NU 319 E 1)
Horizontal motors
6205 2ZC3 4)
6205 2ZC3 4)
6208 2ZC3 4)
6209 2ZC3 4)
6210 ZC3
6212 ZC3
6212 ZC3
6215 ZC3
6216 C3
6317 C3
6217 C3
6319 C3
6217 C3
6319 C3
4 to 8
4 to 8
NU 320 E
NU 322 E
On request
On request
6218 C3
6220 C3
On request
On request
all
all
NU 210
NU 212
6210 ZC3
6212 ZC3
all
all
NU 213
NU 215
6213 C3
6215 C3
Siemens M 11 2003/2004
6319 C3
Squirrel-cage motors
Technical information
Mechanical design
Bearings (continued)
Selection of bearings for 1LG4/6 motors, bearings for high cantilever forces, Order Code K20
For motors
Frame size
Type
1LG4 . . .
1LG6 . . .
Number of poles
Drive-end bearing
180 M
180 L
. . . . 18 .
all
Horizontal motors
NU210
200 L
225 S
225 M
250 M
280 S
280 M
. . . . 20 .
. . . . 22 .
all
all
NU212
NU213
6212 C3
6213 C3
. . . . 25 .
. . . . 28 .
all
2
4 to 8
NU215
NU217
NU317
6215 C3
6217 C3
6317 C3
315 S
315 M
315 L
....
....
....
....
....
2
4 to 8
2
4 to 8
NU219 3)
NU319
NU219 3)
NU319
6219 C3
6319 C3
6219 C3
6319 C3
310
313
316
317
318
Non-drive end
bearing
Vertical motors
Horizontal motors
6210 C3
Vertical motors
Fig. No.
on
page
2/34
Fig. 4
Fig. 5
Bearings for 1LG4/6 motors, strengthened deep-groove ball bearings on both sides, Order Code K36
For motors
Frame size
Type
1LG4 . . .
1LG6 . . .
Number of poles
Drive-end bearing
180 M
180 L
200 L
225 S
225 M
250 M
280 S
280 M
. . . . 18 .
all
Horizontal motors
6310 ZC3 1)
315 S
315 M
315 L
Non-drive end
bearing
Vertical motors
Horizontal motors
6310 ZC3 1)
all
all
6312 ZC3 )
6313 ZC3 1)
6312 ZC3 )
6313 ZC3 1)
. . . . 25 .
. . . . 28 .
all
2
4 to 8
6315 ZC3 1)
6317 C3 2)
6315 ZC3 1)
6317 C3 2)
2
4 to 8
6316 C3
6319 C3 2)
6316 C3
6319 C3 2)
Fig. 4
. . . . 20 .
. . . . 22 .
. . . . 31 .
Vertical motors
Fig. No.
on
page
2/34
Fig. 5
2) As standard version.
3) Only for 50 Hz.
Siemens M 11 2003/2004
2/33
Squirrel-cage motors
Technical information
Mechanical design
Bearings (continued)
Diagrams of bearings
Drive-end bearing
Fig. 3
Drive-end bearing
Non-drive end bearing
Located bearings for 1LA7/1LA9/1MA7, frame sizes 56 to 160
Fig. 2
Drive-end bearing
Fig. 4
Drive-end bearing
Fig. 6
Drive-end bearing
M1-5165
M1-5164a
M1-5166
M1-5012e
M1-5011d
M1-5163a
M1-5013d
M1-5014d
Fig. 1
Frame sizes
280 S to 315 L, 2- to 8-pole
Fig. 7
Drive-end bearing
Frame sizes
315, 2- to 8-pole, IM V1
2/34
Frame sizes
315 to 450, 2- to 8-pole, IM B3
Drive-end bearing
M1-5255
Siemens M 11 2003/2004
M1-5252
M1-5251
Drive-end bearing
M1-5168
Fig. 5
M1-5167
M1-5254
Frame sizes
355 and 450, 2- to 8-pole, IM V1
M1-5253
Frame sizes
315 to 450, 2- to 8-pole, IM V1
Squirrel-cage motors
Technical information
Mechanical design
Bearings (continued)
Diagrams of bearings
Fig. 11
Drive-end bearing
M1-5090a
M1-5092a
M1-5100a
Fig. 13
Drive-end bearing
M1-5101a
M1-5172
M1-5170
M1-5091b
Drive-end bearing
M1-5169
Fig. 12
Drive-end bearing
M1-5089a
Drive-end bearing
Fig. 9
M1-5171
Fig. 10
M1-5099b
Drive-end bearing
M1-5098a
Fig. 8
Siemens M 11 2003/2004
2/35
Squirrel-cage motors
Technical information
Mechanical design
Fu 2 107
Fu
P
n
D
P
n D
Peripheral force in N
Motor rated output
(transmitted power)
in kW
Motor rated speed in rpm
Belt pulley diameter
in mm
240
4
350
305
6
415
360
63 M
2
270
240
4
350
305
6
415
360
71 M
2
415
415
355
355
4
530
530
450
450
6
630
630
535
535
8
690
585
80 M
2
485
485
400
400
4
625
625
515
515
6
735
735
605
605
8
815
675
675
90 S
2
725
725
605
605
90 L
4
920
920
775
775
6
1090
1090
910
910
8
1230
1230
1030
1030
100 L
2
1030
1030
840
840
4
1310
1310
1060
1060
6
1550
1550
1250
1250
8
1720
1720
1400
1400
112 M
2
1010
1680
830
1490
4
1270
1960
1040
1580
6
1520
2140
1240
1720
8
1690
2450
1380
1950
132 S
2
1490
2250
1180
1820
132 M
4
1940
2720
1530
2170
6
2260
3100
1780
2420
8
2500
3400
1980
2700
160 M
2
1540
2800
1210
2250
160 L
4
2040
3330
1590
2600
6
2330
3750
1820
2900
8
2660
3750
2080
2900
180 M
2
2000
1780
2000
1550
1410
1550
180 L
4
2350
2240
2350
1950
1820
1950
6
2800
2550
2800
2250
2120
2250
8
3050
2860
3050
2500
2330
2500
200 L
2
2550
2380
2550
2100
1930
2100
4
3350
3050
3350
2750
2530
2750
6
3900
3500
3900
3200
2930
3200
8
4150
3800
4150
3450
3210
3450
225 S
2
3050
2820
3050
2550
2290
2550
225 M
4
3750
3500
3750
2950
2760
2950
6
4550
4050
4550
3600
3240
3600
8
4850
4500
4850
3900
3500
3900
2/36
Siemens M 11 2003/2004
N
3650
4400
5350
5700
280 S
3350
280 M
8400
10000
11000
315 S
3950
315 M
9900
12100
13300
315 L
3100
8800
11400
12500
1MJ8
1MJ1 1)
315
2
see diagrams
to
to
page
450
8
2/38
1) Data for 1MJ1 available soon
250 M
2
4
6
8
2
4
6
8
2
4
6
8
2
4
6
8
N
3190
4000
4700
5200
4000
8400
9700
10750
4750
9100
10700
11600
4000
8400
9700
11100
1LA8
N
3650
4400
5350
5700
8100
9700
11700
12800
9000
13100
15600
16900
8800
24000
25000
26000
N
2530
3350
3900
4400
3250
7000
8100
9000
3890
7300
8700
9600
3280
7500
9100
10200
1LA8
N
2950
3600
4350
4700
2800
7200
8900
9850
3350
8100
9900
10900
2700
7450
9600
10500
1MJ8
1MJ1 1)
see diagrams
page
2/38
N
2950
3600
4350
4700
6700
8050
9700
10600
7600
10800
12800
13900
7600
12000
12000
12000
Squirrel-cage motors
Technical information
Mechanical design
FQ
M1-5180
Maximum cantilever forces for 50 Hz for type 1LA, 1MA, and 1MJ motors
Parallel roller bearings at drive-end (DE) Order Code K20
For motors
Max. cantilever force at FQ
Size
Type
Number of
at
at
poles
1LA5 . . .
x0
xmax.
1LA6 . . .
1MA6 . . .
1MJ6 . . .
1MJ7 . . . .
N
N
225
. . . . 22 .
2
8100
6800
4
9800
7800
6
11200
8800
8
12200
9700
250
. . . . 25 .
2
9600
7900
4
11600
9600
6
13200
10800
8
14400
11800
280 1)
. . . . 28 .
2
10000
8400
315 S 1)
. . . . 310
2
12000
10200
315 M 1)
. . . . 313
315 L 1)
. . . . 316
2
11800
10200
. . . . 317
(horizontal motors)
Please note that in the case of the IM B 6, IM B 7, IM B 8,
IM V 5, and IM V 6 types of construction, the belt tension is
only allowed to act parallel to or towards the mounting plane
and the feet must be braced.
280 M
315 S
. . . . 310
2
5650
4650
315 M
. . . . 313
315 L
. . . . 316
2
5350
4650
. . . . 317
2/37
Squirrel-cage motors
Technical information
Mechanical design
8
k N
7
Q
8
k N
7
M 1 -5 2 4 7
7 5 0 rp m
1 5 0 0 rp m
5
1 0 0 0 rp m
5
1 0 0 0 rp m
4
3 0 0 0 rp m
3
2
2
1
3 0 0 0 rp m
-1 0
-8
-6
-4
-2
T e n s io n
M 1 -5 2 4 8
7 5 0 rp m
1 5 0 0 rp m
4
P re s s u re
C a n tile v e r fo r c e Q a t x = l ( s h a ft e x te n s io n ) v ia a x ia l fo r c e
b e a r in g s e r v ic e life
h 1 0 = 2 0 0 0 0 h
A
0
6
k N
-1 0
4
6
k N
P re s s u re A
C a n tile v e r fo r c e Q a t x = l ( s h a ft e x te n s io n ) v ia a x ia l fo r c e A a t n o m in a l
b e a r in g s e r v ic e life
h 1 0 = 2 0 0 0 0 h
a t n o m in a l
-8
5
4
4
3 0 0 0 rp m
1
-6
-4
-2
T e n s io n
4
P re s s u re
C a n tile v e r fo r c e Q a t x = l ( s h a ft e x te n s io n ) v ia a x ia l fo r c e
b e a r in g s e r v ic e life
h 1 0 = 2 0 0 0 0 h
A
0
6
k N
A
a t n o m in a l
-1 0
-8
4
6
k N
P re s s u re A
C a n tile v e r fo r c e Q a t x = l ( s h a ft e x te n s io n ) v ia a x ia l fo r c e A a t n o m in a l
b e a r in g s e r v ic e life
h 1 0 = 2 0 0 0 0 h
M 1 -5 1 7 5 b
k N
F Q
M 1 -5 1 7 6 b
k N
F Q
1 6
n = 7 5 0 rp m
n = 7 5 0 rp m
1 2
n = 1 0 0 0 rp m
n = 1 0 0 0 rp m
1 2
n = 1 5 0 0 rp m
1 0
n = 1 5 0 0 rp m
8
8
n = 3 0 0 0 rp m
4
0
0
6 0
1 2 0
m m
1 8 0
x
2/38
Siemens M 11 2003/2004
M 1 -5 2 5 0
3
2
-8
3 0 0 0 rp m
-1 0
7 5 0 rp m
1 5 0 0 rp m
1 0 0 0 rp m
1 0 0 0 rp m
-2
8
k N
7
M 1 -5 2 4 9
1 5 0 0 rp m
-4
T e n s io n
7 5 0 rp m
-6
n = 3 0 0 0 rp m
6 0
1 2 0
m m
1 8 0
x
-6
-4
T e n s io n
-2
Squirrel-cage motors
Technical information
Mechanical design
Maximum cantilever forces at 50 Hz for 1LA, 1LG, and 1MA motors, bearings for high cantilever forces, Order Code K20
Frame size 315, 1 LA8
Design IM B 3
5 0
k N
4 6
M 1 -5 0 8 0 c
Q
Q
4 2
7 5 0 rp m
F Q
1 5 0 0 rp m
3 4
2 8
3 0
2 4
2 6
2 6
2 0
2 2
2 2
1 6
1 0 0 0 rp m
3 0
1 8
1 5 0 0 rp m
4 0
8 0
1 2 0
1 6 0
1 8
2 4 0
m m
x
1 0 0 0 rp m
4 0
k N
3 5
F Q
n = 1 5 0 0 rp m
1 2
2 4 0
8 0
1 2 0
1 6 0
m m
2 4 0
x
1 5
7 5 0 rp m
1 0
1 0
5
5
0
4 0
8 0
1 2 0
1 6 0
2 4 0
m m
x
4 0
8 0
1 2 0
1 6 0
m m
2 4 0
x
M 1 -5 0 5 7 b
7 5 0
rp m
1 0 0
0 rp
m
n = 1
5 0 0
rp m
F Q
4 0
k N
3 6
3 2
2 8
M 1 -5 0 5 8 b
7 5 0
rp m
1 0 0
0 rp
m
F Q
n =
1 5 0
0 rp
m
3 8
k N
3 4
7 5 0
rp m
1 0 0
0 rp
m
3 0
n = 1
5 0 0
rp m
2 4
2 2
1 6
2 0
1 8
4 0
8 0
1 2 0
1 6 0
m m
2 4 0
x
1 6
4 0
8 0
M 1 -5 0 5 9 b
2 6
2 0
1 2
4 0
n = 1 5 0 0 rp m
2 0
2 4
m m
1 0 0 0 rp m
3 0
2 0
2 8
1 6 0
M 1 -5 2 3 7
2 5
3 6
k N
3 2
1 2 0
n = 1 5 0 0 rp m
7 5 0 rp m
2 5
1 5
8 0
1 0 0 0 rp m
M 1 -5 2 3 6
3 0
4 0
7 5 0 rp m
M 1 -5 2 3 5
3 6
3 2
3 4
F Q
1 0 0 0 rp m
4 2
4 4
k N
4 0
M 1 -5 0 8 1 c
3 8
3 8
F Q
7 5 0 rp m
1 2 0
1 6 0
m m
2 4 0
x
1 4
4 0
8 0
1 2 0
1 6 0
m m
2 4 0
x
Siemens M 11 2003/2004
2/39
Squirrel-cage motors
Technical information
Mechanical design
56
63
71
80
90
100
112
132
160
1500 rpm
downwards
Load
down
up
N
N
80
330
80
330
90
380
100
540
100
680
130
990
130
1000
(130)* (1350)*
180
1680
(1500)* (2100)*
1900
1800
(2500)* (2400)*
upwards
Load
down
up
N
N
310
95
310
95
440
130
480
165
580
190
820
285
820
310
(1100)* (300)*
1200
470
(1600)* (470)*
1300
2200
(1720)* (2800)*
1000 rpm
downwards
Load
down
up
N
N
80
410
80
410
90
590
100
650
100
920
130
1280
130
1290
(130)* (1720)*
180
1900
(280)* (2400)*
2200
2200
(2800)* (2800)*
upwards
Load
down
up
N
N
390
95
390
95
550
130
590
165
820
190
1110
285
1110
310
(1500)* (310)*
1600
470
(2100)* (470)*
1600
2700
(2130)* (3600)*
750 rpm
downwards
Load
down
up
N
N
90
700
100
760
100
1150
130
1560
130
1570
(130)* (2000)*
190
2200
(290)* (2800)*
2700
2700
(3600)* (3600)*
upwards
Load
down
up
N
N
660
130
700
165
1050
190
1390
285
1390
310
(1850)* (310)*
1900
440
(2400)* (440)*
1950
2900
(2600)* (3700)*
225 S
225 M
250 M
250 M
280 S
280 M
315 S
315 M
315 L
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
183
186
188
206
207
208
220
223
228
253
258
280
283
288
310
313
316
317
318
1380
1140
1190
1390
1610
1480
1510
1530
2030
1510
1590
1990
2110
1540
1990
1920
1540
2070
1950
1680
2760
2110
1660
2870
2110
390
4670
3190
100
4780
2790
100
4950
2700
840
6330
3380
530
6490
2870
8830
590
2450
8410
690
1800
8170
800
1620
2/40
Siemens M 11 2003/2004
Load
up
N
1600
1630
1650
2100
2120
2690
2770
2840
3740
3960
8200
8340
8570
10200
10500
11000
11400
12000
1000 rpm
Load
down
N
1650
1640
2420
2220
2210
2260
2240
2740
2740
4510
4210
4170
4760
4200
3680
3100
2690
Load
up
N
2000
2030
2550
2610
2680
3300
3430
4350
4520
9290
9450
9600
11500
11800
12300
12800
13400
750 rpm
Load
down
N
2020
1880
2610
2600
2830
2620
2610
3070
3070
5510
5200
5160
5860
5420
4800
4410
3820
Load
up
N
2250
2280
2970
3060
3710
3770
3880
4920
5160
10300
10400
10600
12600
12900
13400
13900
14300
Squirrel-cage motors
Technical information
Mechanical design
56
63
71
80
90
100
112
132
160
3000 rpm
Tensile Thrust load (N)
load
with radial load at without
radial
load
N
x0
xmax.
90
120
90
240
90
120
90
240
120
150
120
350
140
190
150
400
150
300
280
400
220
450
350
630
220
450
350
630
(220)* (850)* (700)* (1050)*
350
650
520
1200
(350)* (1000)* (900)* (1550)*
1500
850
720
1500
(2100)* (1280)* (1100)* (2100)*
1500 rpm
Tensile Thrust load (N)
load
with radial load at without
radial
load
N
x0
xmax.
90
140
110
320
90
140
110
320
120
210
150
460
140
300
260
510
150
400
360
630
220
600
500
910
220
600
500
910
(220)* (1150)* (1000)* (1350)*
350
850
700
1600
(350)* (1250)* (1150)* (2100)*
1500
1050
920
1800
(2100)* (1680)* (1700)* (2350)*
1000 rpm
Tensile Thrust load (N)
load
with radial load at without
radial
load
N
x0
xmax.
90
170
120
400
90
170
120
400
120
260
180
570
140
330
280
620
150
480
430
870
220
650
550
1200
220
650
550
1200
(220)* (1300)* (1150)* (1720)*
350
1020
890
1900
(350)* (1500)* (1400)* (2400)*
1500
1250
1120
2200
(2100)* (2050)* (1920)* (2900)*
750 rpm
Tensile Thrust load (N)
load
with radial load at without
radial
load
N
x0
xmax.
120
300
210
680
140
340
290
730
150
550
500
1100
220
750
650
1480
220
750
650
1480
(220)* (1450)* (1300)* (2000)*
350
1150
1020
2200
(350)* (1750)* (1650)* (2800)*
1500
1350
1220
2600
(2100)* (2400)* (2200)* (3300)*
225 S
225 M
250 M
250 M
280 S
280 M
315 S
315 M
315 L
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
183
186
188
206
207
208
220
223
228
253
258
280
283
288
310
313
316
317
318
3000 rpm
Loading direction
Tension
Thrust
1500 rpm
Loading direction
Tension
Thrust
1000 rpm
Loading direction
Tension
Thrust
750 rpm
Loading direction
Tension
Thrust
N
1550
1550
2150
2130
2130
2320
2320
2510
2510
1790
1720
1720
2610
2500
2450
2320
2300
N
1950
1890
1900
2670
2630
2950
2910
2910
3150
3140
4970
4860
4850
5520
5320
5230
5050
4950
2220
2220
3090
3030
3020
3360
3350
3750
3750
6180
6110
6100
6830
6520
6370
6110
5950
2470
2460
3410
3410
3820
3760
3760
4180
4170
7170
7090
7080
7940
7850
7520
7350
7080
N
790
790
990
970
970
1290
1290
1710
1710
3360
3290
3290
4180
4070
4020
3890
3870
The figures for the maximum axial loads have been calculated
assuming the maximum permitted cantilever forces.
N
1190
1130
1140
1520
1480
1920
1880
1880
2350
2340
6540
6430
6420
7520
7320
7230
7050
6950
1460
1460
1940
1880
1870
2330
2320
2950
2950
7750
7680
7670
8830
8520
8370
8110
7950
1710
1700
2260
2250
2790
2740
2730
3380
3370
8740
8660
8650
9940
9850
9520
9350
9080
2/41
Squirrel-cage motors
Technical information
Mechanical design
Size
Type
1LA5 . . .
1MA6 . . .
1MJ6 . . .
1MJ7 . . .
180 M . . . . 183
180 L . . . . 186
200 L . . . . 206
. . . . 207
225 S . . . . 220
225 M . . . . 223
250 M . . . . 253
280 S . . . . 280
280 M . . . . 283
315 S . . . . 310
315 M . . . . 313
315 L . . . . 316
. . . . 317
. . . . 318
1LA8 . . .
315
355
400
450
....
....
....
....
....
....
....
....
....
....
....
315
317
353
355
357
403
405
407
453
455
457
1000 rpm
Load down
Load up
1LA5... 1MJ6... 1LA5... 1MJ6...
1MA6... 1MJ7... 1MA6... 1MJ7...
750 rpm
Load down
Load up
1LA5... 1MJ6... 1LA5... 1MJ6...
1MA6... 1MJ7... 1MA6... 1MJ7...
N
1150
1650
1550
1890
1750
380
180
210
100
9270
9270
9270
1700
2550
2400
2700
2740
5340
5000
5150
4740
3650
2990
2990
2000
2800
3200
3040
2990
6280
5930
6520
5801
4630
3760
3760
N
1150
1650
1550
1890
1750
1150
900
900
650
N
1900
1440
8480
8180
7530
6780
6330
5930
5330
4730
4130
2/42
N
1900
2750
2800
2190
2790
4480
4580
5270
5350
770
840
840
N
5240
5680
5570
5860
6500
7260
7700
8100
9650
10250
10840
N
1900
2750
2800
2190
2790
3850
3900
4500
4550
N
1400
1400
2000
2300
2180
2160
3830
3550
3700
3330
2330
1370
1370
N
2790
2280
14550
14200
13400
17640
17040
16340
17720
17020
16270
N
1400
1400
2000
2300
2180
2160
1350
1000
1700
1600
N
2350
2400
3350
3020
3060
3760
8790
8910
10200
10400
10400
10800
10800
N
6930
7420
7900
8240
9030
11160
11750
12440
13020
13720
14460
Siemens M 11 2003/2004
N
2350
2400
3350
3020
3060
3760
4950
5000
6400
6900
N
3060
2390
15690
14540
19500
18750
17900
19950
19050
18000
1700
2550
2400
2700
2740
2350
2000
2300
2050
2850
3950
3950
3500
4340
10000
10100
11700
11700
11700
11600
11600
2850
3950
3950
3500
4340
5650
5700
7050
7500
N
8600
9230
10650
11780
14160
14910
15750
16250
17140
18180
The figures for the maximum axial loads have been calculated
assuming that standard coupling types are used for the
drive. For suppliers, see catalogue section "Accessories and
Repair parts".
N
3850
3190
17840
16690
22260
21510
20660
23040
22140
21090
2000
2800
3200
3040
2990
2850
2450
3400
2800
3150
4500
4080
4120
4890
11000
11100
13000
13000
13000
13000
13000
3150
4500
4080
4120
4890
6250
6300
7950
8400
N
9390
10030
11650
12780
15330
16070
16910
17550
18440
19480
Squirrel-cage motors
Technical information
Mechanical design
Type
1LA5 . . .
1MA6 . . .
1MJ6 . . .
1MJ7 . . .
180 M
180 L
200 L
....
....
....
....
....
....
....
....
....
....
....
....
....
....
225 S
225 M
250 M
280 S
280 M
315 S
315 M
315 L
183
186
206
207
220
223
253
280
283
310
313
316
317
318
3000 rpm
Loading direction
Tension
Thrust
1500 rpm
Loading direction
Tension
Thrust
1000 rpm
Loading direction
Tension
Thrust
N
1400
2000
1950
2390
2450
1330 (3700)*
1200 (3600)*
1500 (3800)*
1400 (3650)*
1080
940
940
N
1700
1700
2450
2980
2900
3070
5080 (4200)*
4990 (4000)*
5350 (4900)*
5260 (4900)*
4580
4170
4170
N
N
N
2050
2050
2400
3000
3000
2900
2900
3400
3880
3380
2360
3810
3620
2820
4000
6410 (5000)* 8070 (3400)* 7390 (5550)*
6260 (4800)* 7920 (3200)* 7220 (5350)*
6740 (5500)* 8810 (3900)* 8010 (6500)*
6560 (5450)* 8660 (3850)* 7690 (6250)*
5770
7870
6820
5410
7510
6410
5410
7510
6410
N
1400
2000
1950
1370
1655
2900 (2100)*
2800 (2000)*
3160 (2200)*
3180 (2050)*
2740
2600
2600
The figures for the maximum axial loads have been calculated
assuming that standard coupling types are used for the
drive. For suppliers, see catalogue section "Accessories and
Repair parts".
N
1700
1700
2450
1960
1880
2270
6740 (2600)*
6650 (2400)*
7450 (3300)*
7360 (3300)*
6680
6270
6270
750 rpm
Loading direction
Tension
Thrust
2400
3400
2860
2790
3200
9050 (3950)*
8880 (3750)*
10110 (4900)*
9790 (4650)*
8920
8510
8510
2/43
Squirrel-cage motors
Technical information
Converter-fed operation
In general, all motors are suitable for converter-fed operation. Some motors require special measures.
The planning notes for drives
with a constant or square-law
counter-torque are contained in
the following catalogues:
MICROMASTER:
Catalogue series DA 64 and
DA 51
SIMOVERT MASTERDRIVES:
Catalogue series DA 65
These catalogues also contain
tables showing which squirrelcage motors should be assigned to which SIMOVERT
converter, depending on the
load characteristic of the driven
machine.
All data specified in Catalogue
M11 applies to 50 Hz supply
systems.
Attention should be paid to the
reduction factors for constanttorque drives, pump drives and
compressor drives.
Motor temperature detection
KTY 84 temperature sensor:
Order Code:
A23 = 1 x KTY 84-130,
A25 = 2 x KTY 84-130
M1-5178
R
2
kW
ID = 2 mA
1
0
0
100
C 200
TU
300
2/44
Siemens M 11 2003/2004
Insulation
The insulation of 1LA and 1LG
motors is such that they can operate unrestrictedly in converter-fed mode up to voltages of
500 V. The same applies to
operation with pulse-controlled
AC converters with voltage front
times ts > 0.1 ms at the motor terminals.
Providing these conditions are
met, all motors with voltage
codes 1, 3, 5, and 6 can be operated in converter-fed mode,
except for those with voltage
ratings of > 500 V to 690 V,
which are supplied with special
insulation for operation with a
pulse-controlled AC converter
(SIMOVERT MASTERDRIVES,
MM440 > 500 V 600 V) but
without a converter circuit (du/dt
filter or sine filter) (10th position
of the Order No. = "M").
For operation with a converter at
the outputs specified in the catalogue, the motors are utilized
according to temperature class
F. Order Codes C11, C12 and
C13 are not possible.
Connection of the motors
In addition to the restrictions applying to mains-connected machines, the maximum permissible conductor cross-sections
for the converter must also be
kept in mind when the motors
are connected.
Ventilation/
noise
Increased fan noise may occur
in self-ventilated motors at
speeds higher than the rated
speed.
To increase motor utilization for
low speeds, it is advisable to
use separately ventilated motors such as 1LA5, 1LA7, 1LG,
and 1LG6 with Order Code G17
or motor 1PQ8.
Mechanical stress, grease life
Due to the higher speeds beyond the rated speed value and
the resulting increased vibration, the mechanical balance
quality changes and the bearings are under greater mechanical stress. This reduces the
grease life and the bearing life.
(enquire if necessary).
Bearings
To avoid damage by bearing
currents, isolated bearings for
frame sizes 225 to 315 are available and recommended for
frame size 280 (Order Code
L27)1). These are standard in
1LA8 motors for converter-fed
operation on SIMOVERT
MASTERDRIVES (9 th position
of the Order No. = "P").
Squirrel-cage motors
Technical information
Converter-fed operation
1LA7/1LA9 056
1LA7/1LA9 063
1LA7/1LA9 071
1LA7/1LA9 080
1LA7/1LA9 090
1LA6/1LA7/1LA9 10 .
1LA6/1LA7/1LA9 113
1LA6/1LA7/1LA9 13 .
1LA6/1LA7/1LA9 16 .
1LA5/1LA9 18 .
1LA5/1LA9 20 .
1LA5 22 .
1LA8 31 .
1LA8 35 .
1LA8 40 .
2-pole
nmax.
rpm
6000
6000
6000
6000
6000
6000
6000
5600
4800
4600
4500
4500
3600
3600/3100 1)
3600/3100 1)
1LA8 45 .
3000
fmax.
Hz
100
100
100
100
100
100
100
90
80
75
75
75
60
60/52 1)
60
52 1)
50
1LG4/1LG6 18 .
1LG4/1LG6 20 .
1LG4/1LG6 22 .
1LG4/1LG6 25 .
1LG4/1LG6 28 .
1LG4/1LG6 310
1LG4/1LG6 313
1LG4/1LG6 316
1LG4/1LG6 317
1LG4/1LG6 318 .
1MJ6 07.
1MJ6 08.
1MJ6 09.
1MJ6 10.
1MJ6 11.
1MJ6 13.
1MJ6 16.
1MJ6 18.
1MJ6 20.
1MJ7 22
1MJ7 25 .
1MJ7 28 .
1MJ7 31 .
4600
4500
4500
3900
3600
3600
3600
3600/3000 1)
3600/3000 1)
6000
6000
6000
5400
5400
4800
4500
5100
5100
4500
3900
3600
3600/3000 1)
76
75
75
65
60
60
60
60/50 1)
60/50 1)
100
100
100
90
90
80
75
85
85
75
65
60
60/50 1)
4-pole
nmax.
rpm
4200
4200
4200
4200
4200
4200
4200
4200
4200
4200 (3800)
4200 (3800)
4500 (3800)
3000 (2650)
2500 (2350)
2200/(2100)
2100 1)
2100/(1900)
1800 1)
4200 (3400)
4200 (3400)
4500 (3400)
3700 (3400)
3000
2600
2600
2600
2600
3000
3000
3000
3000
3000
3000
3000
3000
3000
3800
3700
3000
2600
fmax.
Hz
140
140
140
140
140
140
140
140
140
140 (126)
140 (126)
150 (126)
100 (88)
83 (78)
73/(70)
70 1)
70/(63)
60 1)
140 (113)
140 (113)
150 (113)
123 (113)
100
87
87
87
87
100
100
100
100
100
100
100
100
100
126
123
100
87
6-pole
nmax.
rpm
3600
3600
3600
3600
3600
3600
3600
3600
3600
3600
3600
4400 (3400)
2950 (2350)
2500 (2100)
2200/(1900)
2100 1)
2100/(1700)
1800 1)
3600 (3400)
3600 (3400)
4400 (3400)
3700 (3000)
3000 (2800)
2600
2600
2600 (2500)
2600 (2500)
2600 (2500)
2000
2000
2000
2000
2000
2000
2000
2000
2000
3400
3400
3000
2600
fmax.
Hz
180
180
180
180
180
180
180
180
180
180
180
220 (170)
147 (117)
125 (105)
110/(95)
105 1)
105/(85)
90 1)
180 (170)
180 (170)
220 (170)
185 (150)
150 (140)
130
130
130 (125)
130 (125)
130 (125)
100
100
100
100
100
100
100
100
100
170
170
150
130
8-pole
nmax.
rpm
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
4400 (3400)
2950 (2350)
2500 (2100)
2200/(1900)
2100 1)
2100/(1700)
1800 1)
3000
3000
4400 (3400)
3700 (3000)
3000 (2800)
2600
2600
2600 (2500)
2600 (2500)
2600 (2500)
1500
1500
1500
1500
1500
1500
1500
1500
1500
3400
3400
3000
2600
fmax.
Hz
200
200
200
200
200
200
200
200
200
200
200
293 (226)
196 (156)
166 (140)
146/(126)
140 1)
140/
120 1)
200
200
293 (226)
247 (200)
200 (187)
176
173
173 (167)
173 (167)
173 (167)
100
100
100
100
100
100
100
100
100
226
226
200
173
2/45
Squirrel-cage motors
Technical information
Main characteristics
Power range:
0.37 - 3.0 kW, 400 V, 3AC
IP66 degree of protection
(MICROMASTER 411), selfcooling
Electrical isolation of electronics and connection terminals
Parameter sets for fast commissioning and cost-saving
Modular construction with
many accessories
Operation without operator
panel possible (if jumpers
and/or control potentiometers
are used)
Integrated control potentiometer which can be accessed
from the outside.
Accessories (overview)
Basic Operator Panel
(BOP) for parameterizing a
converter
Clear text Advanced Operator
Panel (AOP) for
MICROMASTER 411 and
COMBIMASTER 411 with multilingual display
PROFIBUS module
AS-Interface module
DeviceNet module
REM module (dynamic brake
and control module for electromechanical brake)
EM module (electromechanical brake control module)
PC connecting set
Assembly sets for fitting the
operator panel
PC commissioning programs.
ECOFAST
ECOFAST is a system which
permits extensive decentralization and a modular structure for
installation elements on the
component level
(MICROSTARTER,
COMBIMASTER 411,
MICROMASTER 411 and motor
connector (Order Code G55),
alternatively EMC resistant motor connector (Order Code
G56)).
Note:
Only one sensor (temperature
sensor or PTC thermistor) connectable.
2/46
Siemens M 11 2003/2004
Ordering example
Motor data:
P2 = 5.5 kW, 4-pole, eff1,
star-delta starting for a supply
voltage of 400 V/50 Hz
Order number:
1LA9130-4KA90-Z
G55+L1U
Further information under:
http://www.siemens.com/
ecofast
Squirrel-cage motors
Technical information
MICROSTARTER
The new MICROSTARTER is a
module for distributed drive
technology. It can be used as a
direct-on-line starter or reversing starter up to a motor output
of 4 kW (motor frame size 63 M
to 112 M).
A stable die-cast aluminum enclosure with IP65 degree of protection is fitted instead of the
motor terminal box. In addition
to the control and evaluation
electronics, it includes a directon-line or reversing contactor
(depending on the version).
The MICROSTARTER is always
equipped with a PTC thermistor
detector (Order Code A11) and
the corresponding electronic
evaluation system. If the motor
overheats, MICROSTARTER will
automatically trip. This obviates
the need for an external tripping
unit for PTC thermistors.
Technical data
Rated output
Degree of protection
Mounting position
Max. ambient temperature
V during operation
V during storage and transport
Shock resistance
Vibratory load
No-load switchover frequency
Rated voltage
Overload protection
Short-circuit protection for a power
supply with
V ECOFAST plug-in connector
V metric cable entry port
Types
up to 4 kW,
frame sizes 63 M to 112 M
IP65
any
20 C to +40 C
20 C to +70 C
5 g/10 ms
3g
100 switchovers/h
3 AC 50 HZ 380 V to 420 V 5%
3 AC 60 Hz 440 V to 480 V 5%
Motor thermistor analysis
LED display
(with AS-Interface connection)
Connection of external sensors
(with AS-Interface connection)
Minimum/maximum cross-sections of
connections at contactor
(for metric cable entries)
Direct-on-line starter:
V finely stranded with end sleeve
2 x (0.75 to 1.5) mm2 or
1 x (0.75 to 2.5) mm2
V single-wire without end sleeve
2 x (1 to 2.5) mm2 or
1 x 4 mm2
Reversing starter:
V finely stranded with end sleeve
2 x (0.75 to 1.5) mm2
V single-wire without end sleeve
2 x (1 to 1.5) mm2
AS-Interface
V Motor starter profile
7D
via address jack
V Addressing
with addressing unit
via adapter plate with
V Connection for yellow and black
insulation piercing method
trapezoidal-section cable
V Total current input
250 mA
Direct-on-line
starter
with DC 24 V control
Direct-on-line
starter
with AS-I connection
Reversing starter
with AS-I connection
Weight
kg
Order
code
1.25
1.30
H90
H91
M25
HAN Q8
92 x 151 x 154
92 x 167 x 154
1.35
1.40
H92
H93
M25
HAN Q8
92 x 151 x 154
92 x 167 x 154
1.50
1.55
H94
H95
"Modular technology"
H57 (from size 100)
H58 (from size 100)
G17 (from size 100)
H61 (from size 100)
"Mechanical versions"
D30, D31, D40
K01, K16, K17
K20 (from size 100)
K30, K31
K40 (from size 100)
K94
L04, L13, L99
Y82
Siemens M 11 2003/2004
2/47
Squirrel-cage motors
Technical information
Modular technology
Brake,
frame sizes 63 to 315L
0 .0 2
8 0
5 8
4 2 .5
0 .5
4 9 .5
Siemens M 11 2003/2004
M 1 -5 2 4 6
2/48
0 .0 1 /
1 2
The range of potential applications for the 1LA and 1LG motors can be broadened considerably in combination with the
following built-on accessories
(e.g. the motors can be used as
brake motors).
300 kHz
12000 rpm
20 C to +100 C
IP66
60 N
40 N
CSA, UL
0.3 kg
Squirrel-cage motors
Technical information
Modular technology
112 M
132 S/M
160 M to 225 M 1)
250 M to 280 M
315-2-pole
315-4- . . . 8-pole
Frequency
Hz
50
50
60
60
50
50
60
60
50
50
60
60
50
50
60
60
50
50
60
50
50
60
50
50
60
Rated speed
rpm
2680
2680
3000
3000
2760
2760
3120
3120
2690
2690
2960
2960
2690
2690
2980
2980
2720
2720
3320
2750
2750
3365
2720
2720
3320
Rated output
kW
0.062
0.062
0.052
0.052
0.097
0.097
0.098
0.098
0.164
0.164
0.212
0.212
0.269
0.269
0.354
0.354
0.450
0.450
0.520
0.650
0.650
0.750
0.450
0.450
0.520
Rated current
A
0.24
0.14
0.16
0.09
0.43
0.25
0.29
0.17
0.59
0.34
0.52
0.30
0.95
0.55
0.84
0.48
2.00
1.15
1.05
2.85
1.64
1.60
2.00
1.15
1.05
Mounting of separately driven fan for 1LA5, 1LA6, 1LA7 and 1LG motors
Design
Separately driven fan
incl. mounting parts 2)
Size
100
112
132
160
180
200
225 3)
250
280
315
315
100
112
132
160
180
200
225 3)
Number of poles
all
all
all
all
all
all
all
all
all
2
4 to 8
all
all
all
all
all
all
all
Order No.
2CW2 185-8RF14-1AA0
2CW2 210-8RF14-1AA1
2CW2 250-8RF14-1AA2
2CW2 300-8RF14-1AA3
2CW2 300-8RF14-1AA4
2CW2 300-8RF14-1AA5
2CW2 300-8RF14-1AA6
1PP9 063-2LA12-Z A11+K50
1PP9 063-2LA12-Z A11+K50
1PP9 070-2LA12-Z A11+K50
1PP9 063-2LA12-Z A11+K50
2CW2 185-8RF14-2AA0
2CW2 210-8RF14-2AA1
2CW2 250-8RF14-2AA2
2CW2 300-8RF14-2AA3
2CW2 300-8RF14-2AA4
2CW2 300-8RF14-2AA5
2CW2 300-8RF14-2AA6
2/49
Squirrel-cage motors
Technical information
Modular technology
Brakes
Spring-operated disk brakes
are used. Depending on the
motor selected, brake types
2LM8 or KFB are used. Standard brakes are for connection
to 230 V and delivered with a
rectifier.
Rating plate
The motors have a second rating plate with the brake data on
the opposite side of the motor.
Please enquire if the brake motors are used at subzero temperatures or in very humid environments (e.g. in a maritime climate) with long downtimes.
Connection
The main terminal box of the
motor contains labeled terminals for connecting the brake.
The AC voltage for the excitation winding of the brake is connected to the two free terminals
of the rectifier block (~).
S L
When the motor brakes, the rotor - which can be axially shifted
on the hub or the shaft - is
pressed via the armature disk
against the opping frictional surfaces by means of the springs.
When the brake is applied,
there is an air gap SL between
the armature disk and the solenoid component. The solenoid
coil is energized with DC voltage in order to release the
brake. The resulting magnetic
force pulls the armature disk towards the solenoid component
against the spring force. The
spring force is then no longer
applied to the rotor, so that the
latter is able to rotate freely.
1
2
3
4
5
6
Armature disk
Compr. springs
Ax. sliding rotor
Hub
Shaft
Opposing frictional surface
7 Solenoid comp.
SA1-5018
1 +
V 1
2 +
D 2
V 2
_
M 1 -5 2 4 0
Siemens M 11 2003/2004
2 +
2 +
D 2
V 2
D 4
D 3
_
M 1 -5 2 4 1
V 1
L+ L-
2/50
2 +
M1-5179
Squirrel-cage motors
Technical information
Modular technology
Brakes (continued)
Performance of spring-operated brakes with standard excitation
For
motors
Frame
size
63
71
80
90
100
112
132
160
180
200,
225
Brake type
2LM8 005-1NA10
2LM8 005-1NA60
2LM8 005-1NA80
2LM8 005-2NA10
2LM8 005-2NA60
2LM8 005-2NA80
2LM8 010-3NA10
2LM8 010-3NA60
2LM8 010-3NA80
2LM8 020-4NA10
2LM8 020-4NA60
2LM8 020-4NA80
2LM8 040-5NA10
2LM8 040-5NA60
2LM8 040-5NA80
2LM8 060-6NA10
2LM8 060-6NA60
2LM8 060-6NA80
2LM8 100-7NA10
2LM8 100-7NA60
2LM8 100-7NA80
2LM8 260-8NA10
2LM8 260-8NA60
2LM8 260-8NA80
2LM8 315-0NA10
2LM8 315-0NA60
2LM8 315-0NA80
2LM8 400-0NA10
2LM8 400-0NA60
2LM8 400-0NA80
Rated
brake
torque at
100 rpm
Nm
5
1500
rpm
%
87
3000
rpm
%
80
max.
speed
%
65
87
80
65
10
85
78
65
20
83
76
66
40
81
74
66
60
80
73
65
100
79
72
65
260
75
68
65
315
75
68
65
400
73
68
65
V
AC 230
AC 400
DC 24
AC 230
AC 400
DC 24
AC 230
AC 400
DC 24
AC 230
AC 400
DC 24
AC 230
AC 400
DC 24
AC 230
AC 400
DC 24
AC 230
AC 400
DC 24
AC 230
AC 400
DC 24
AC 230
AC 400
DC 24
AC 230
AC 400
DC 24
Brake rating
Current/
Power input 1)
Brake
Brake Brake moapplirelease ment of incation
time
ertia
2
time t2 )
Noise
Lifetime
level Lp
of brake
with rated lining L
air gap
A
0.1
0.11
0.83
0.1
0.11
0.83
0.12
0.14
1.04
0.15
0.17
1.25
0.2
0.22
1.67
0.25
0.28
2.1
0.27
0.31
2.3
0.5
0.47
4.2
0.5
0.56
4.2
0.55
0.61
4.6
W
20
ms
25
ms
56
kg m2
0.000013
dB(A)
77
20
25
56
0.000013
77
105
16
25
26
70
0.000045
75
270
29
32
37
90
0.00016
75
740
79
40
43
140
0.00036
80
1350
115
53
60
210
0.00063
77
1600
215
55
50
270
0.0015
77
2450
325
100
165
340
0.0073
79
7300
935
100
152
410
0.0073
79
5500
470
110
230
390
0.0200
93
9450
1260
Nm 106 Nm 106
105
16
Siemens M 11 2003/2004
2/51
Squirrel-cage motors
Technical information
Modular technology
Brakes (continued)
Lifetime of the braking lining
The braking energy LN until the
brake needs to be adjusted depends on various factors, and
particularly on the masses that
are braked, the operating
speed, the operating frequency
and thus the temperature on the
friction faces. It is therefore not
possible to specify a value for
the friction energy until readjustment that is valid for all operating conditions.
Q p e rm .
2 L M 8 4 0 0
P e r m is s ib le s w itc h in g e n e r g y
1 0
2 L M 8 2 6 0
2 L M 8 1 0 0
J
2 L M 8 0 6 0
2 L M 8 0 4 0
2 L M 8 0 2 0
4
1 0
2 L M 8 0 1 0
2 L M 8 0 0 5
1 0
Maximum speeds
Please refer to the table below
for the maximum speeds at
which an emergency stop is
permissible. These speeds
should be considered as recommended values and confirmed by testing under actual
operating conditions.
1 0
The maximum permitted braking energy depends on the operating frequency and is shown
for the various brakes on the
graph opposite ("Permissible
switching energy as a function
of operating frequency"). Greater wear occurs during emergency braking.
1 0
1 0
Max. rpm
For motors
Frame size
63
71
80
90
100
112
132
160
180
200,
225
2/52
Brake type
2LM8 005-1NA . .
2LM8 005-2NA . .
2LM8 010-3NA . .
2LM8 020-4NA . .
2LM8 040-5NA . .
2LM8 060-6NA . .
2LM8 100-7NA . .
2LM8 260-8NA . .
2LM8 315-0NA . .
2LM8 400-0NA . .
Siemens M 11 2003/2004
M 1 -5 1 4 7 a
2 L M 8 3 1 5
1 0
h
1 0
O p e r a tin g fr e q u e n c y
-1
1 0
S n
Dim.
"O1"
Min.
braking
torque
Rated air
gap
SLNenn
Max. air
gap
SLmax.
Min. rotor
thickness
hmin.
Horizontal
mounting
rpm
6000
6000
6000
6000
6000
6000
5300
4400
4400
3000
mm
7.0
7.0
8.0
7.5
12.5
11.0
13.0
17.0
17.0
21.0
Nm
3.7
3.7
7.0
18.2
21.3
32.8
61.1
157.5
178.4
248.7
mm
0.2
0.2
0.2
0.2
0.3
0.3
0.3
0.4
0.4
0.5
mm
0.4
0.4
0.45
0.55
0.65
0.75
0.75
1.2
1.0
1.5
mm
4.5
4.5
5.5
7.5
8.0
7.5
8.0
12.0
12.0
15.5
Vertical
mounting
rpm
6000
6000
6000
6000
6000
6000
5000
3200
3200
3000
Nm
0.17
0.17
0.35
0.76
1.29
1.66
1.55
5.6
5.6
6.15
Squirrel-cage motors
Technical information
Modular technology
Brakes (continued)
Changing the braking torque
The brake is supplied with a
preset torque. For 2LM8 brakes,
it is possible to reduce this
torque to the dimension o1 by
unscrewing the adjusting ring
with a hook spanner.
The braking torque changes by
the values shown in the above
table for each notch of the adjusting ring.
SA1-5022
h min.
S L
(S L Nenn )
(S L max. )
O
O1
KFB brake
Siemens M 11 2003/2004
2/53
Squirrel-cage motors
Technical information
Modular technology
Brakes (continued)
The brake can also be supplied
for other voltages.
Brake connection voltage:
24 V DC Order Code C00
2x 400 V AC Order Code C01
Order Codes C00 and C01 must
only be used in conjunction with
Order Code G26.
Rating plate
The motors have a second rating plate with the brake data on
the opposite side of the motor.
Connection
The motors are fitted with an additional terminal box next to the
main terminal box which is used
for the brake connection.
KFB brakes are equipped with a
standard rectifier bridge or halfway rectifier. Special connections are not required. Optimal
operating times are achieved
without special circuitry.
Mechanical manual release
The brakes can be released
manually with screws as standard. The brakes can be supplied with a mechanical manual
release using an actuator lever.
Order Code K82.
1 Armature disk
2 Compr. springs
3 Axially sliding
friction lining carrier
4 Hub
5 Shaft
6 Opp. frict.surface
7 Solenoid coil
6
M 1 -5 2 4 2
The brake (air gap) can be adjusted in the workshop, for example, and mounted to the
motor without further adjustments.
D 1
1 +
V 1
2 +
D 2
2 +
V 2
_
M 1 -5 2 4 0
2 +
2 +
D 2
V 2
D 4
D 3
_
M 1 -5 2 4 1
V 1
L+ L-
2/54
Siemens M 11 2003/2004
Squirrel-cage motors
Technical information
Modular technology
Brakes (continued)
Number of poles
Non-drive end bearing
Flange bearing plate for non-drive end
brake mounting
Max. diameter for second drive shaft
Brake type
Braking torque
nmax IMB3
nmax IMV1
Output at 110 V DC
Current at 230 V AC (207 V coil voltage)
Current at 400 V AC (180 V coil voltage)
Current at 110 V DC
Current at 24 V DC
Application time t2
Release time
Brake moment of inertia
Lifetime of brake lining L
Air gap must be readjusted after braking
energy LN
Configuration of brake
motors
Braking time
The time it takes the motor to
come to a standstill comprises
two components:
a) The application time of the
brake t2
b) The braking time tBr
t Br
J nN
9.55 MB o ML
U
nN
t Br
t 2
60
2
Nm
rpm
rpm
W
A
A
A
A
ms
ms
kg m2
Nm 106
Nm 106
For motor
Size
180 1)
2 to 8
6310C3
A300
200 1)
2 to 8
6312C3
A350
225 2)
2 to 8
6313C3
A350
250 2)
2 to 8
6215C3
A400
280 2)
4 to 8
6317C3
A450
315 2)
4 to 8
6319C3
A550
48k6
KFB 25
250
6000
6000
158
0.77
0.8
1.44
5.21
70
240
0.0048
3600
810
55m6
KFB 40
400
5500
5500
196
0.91
1.18
1.78
6.92
80
250
0.0068
3110
935
55m6
KFB 40
400
5500
5500
196
0.91
1.18
1.78
9.62
80
250
0.0068
3110
935
48m6 3)
KFB 63
630
4700
4700
220
1
1.25
2
8.17
110
340
0.0175
4615
1185
65m6
KFB 100
1000
4000
4000
307
1.53
1.8
2.79
12.2
125
370
0.036
7375
2330
70m6
KFB 160
1600
3600
3600
344
1.64
2.1
3.13
12.8
180
500
0.050
10945
3485
Qkin
J nN2
182.4
L
Qzul
Smax
QL
oML nN t Br
19.1
N
ML average load moment in
Nm
LN
Qzul
ML is positive if it is directed
against braking
ML is negative if it supports
braking
1) The standard brake for frame sizes 180 and 200 is brake 2LM8.
KFB brake on request.
2) The standard brake for frame sizes 225 to 315 is the KFB brake.
Siemens M 11 2003/2004
2/55
Squirrel-cage motors
Technical information
Modular technology
8 5
7 6
5 7
M 1 -5 1 5 5 b
M 1 -5 1 5 4 b
M 1 -5 1 5 6 c
M 1 -5 1 5 7 b
M 1 -5 1 5 9 b
M 1 -5 1 5 8 b
311
M1-5191
M 1 -5 1 6 0 b
2/56
Siemens M 11 2003/2004
Squirrel-cage motors
Technical information
Modular technology
2
Separately
driven
fan
(G17)
Brake
and separately
driven
fan
(H63)
Extra
weight
for separately
driven
fan
(G17)
Extra
weight for
brake and
separately driven
fan (H63)
Rotary
pulse encoder and
separately driven
fan (H61,
H97)
approx. kg Dl [mm]
Brake,
Brake
separate- (G26)
ly driven
fan, and
rotary
pulse
encoder
(H64, H99)
Dl [mm]
Dl [mm]
Extra
weight
for brake
(G26)
approx.
kg
Dl [mm]
mm
78
78
78
78
78
78
78
89
89
89
89
89
89
89
134
134
134
134
134
134
134
91
91
91
91
91
91
91
72
72
72
72
72
72
116
116
116
116
116
116
86
86
86
86
86
86
89
89
89
89
133
133
133
133
101
101
101
101
124
137
155
200
242
245
245
124
137
155
200
242
245
245
4.0
4.5
5.5
7.0
10.0
11.0
11.0
233
237
235
235
235
247
233
237
576
578
550
577
10
11
22
25
28
36
10
12.5
17.5
33
37
52
52
209
212
225
250
242
245
245
209
212
225
250
242
245
245
51
51
54
75
78
87
106
129
137
142
142
233
237
425
425
425
437
233
237
519
505
507
545
125
137
239
225
227
265
1
1
2
4
6
8
12
26
27
41
41
156
165
184
207
215
220
220
202
227
226
320
358 (311)
398 (311)
398 (311)
22
32
63
83
118
255
203
215
317
303
305
343
356
396
439
489
539
604
1LG4, 1LG6
180
200
225
250
280
315
63
63
63
63
63
63
32
43
85
108
146
291
1LA8
315
355
400
450
2/57
Squirrel-cage motors
Technical information
bined with the rotary pulse encoders from the "Further mountings" range.
2/58
Siemens M 11 2003/2004
6 9 .5
M 1 -5 2 4 3
1 0 0
G 7
2 4 .5
1 6
6 7
Squirrel-cage motors
Technical information
~ 6 7
1 6
8 8
H 7
M 1 -5 2 0 0 a
1 0 4 .5
Manufacturer:
Hbner Elektromaschinen AG
10967 Berlin
Planufer 92b
http://www.huebner-berlin.de
1 0 5
1 6
M 1 -5 2 0 1 a
H 7
1 1 2
Manufacturer:
Hbner Elektromaschinen AG
10967 Berlin
Planufer 92b
http://www.huebner-berlin.de
Siemens M 11 2003/2004
2/59
Squirrel-cage motors
Technical information
Notes
2/60
Siemens M 11 2003/2004
Squirrel-cage motors
1LA and 1LG
selection and ordering data
3/2
3/3
3/4
3/5
3/6
3/8
3/9
3/10
3/11
3/12
1LA5 to 1LA8, 1LG4 and 1LG6 motors
Frame sizes
Output range
Temperature class F
Converter compatible
56 to 450
0.06 to 1000 kW
used acc. to class B
Voltage peak times
ts > 0.1 ms at U 500 V
3/14
3/16
3/17
3/18
3/20
3/21
3/22
3/23
3/24
3/26
3/27
3/28
3/30
3/1
Squirrel-cage motors
Rated Size
output
Order No.
Efficiency
Order No.
supplement for volt- class
age and type of construction, see table
below
4/4- 3/4load
%
%
rpm
kW
Starting
torque
Stalling
torque
Starting
current
current
torque
Nm
kg m2
kg
Energy-saving motor to CEMEP "Improved Efficiency" eff2, IP55 degree of protection, temperature class F
3000 rpm, 2-pole, 50 Hz
0.09
0.12
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
56 M
63 M
71 M
80 M
90 S
90 L
100 L
112 M
132 S
160 M
160 M
160 L
180 M
200 L
225 M
1LA7 0502AA . .
1LA7 0532AA . .
1LA7 0602AA . .
1LA7 0632AA . .
1LA7 0702AA . .
1LA7 0732AA . .
1LA7 0802AA . .
1LA7 0832AA . .
1LA7 0902AA . .
1LA7 0962AA . .
1LA7 1062AA . .
1LA7 1132AA . .
1LA7 1302AA . .
1LA7 1312AA . .
1LA7 1632AA . .
1LA7 1642AA . .
1LA7 1662AA . .
1LA5 1832AA . .
1LA5 2062AA . .
1LA5 2072AA . .
1LA5 2232AA . .
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2830
2800
2820
2830
2740
2800
2855
2845
2860
2880
2890
2905
2925
2930
2940
2940
2940
2940
2945
2945
2960
63.0
65.0
63.0
65.0
66.0
71.0
73.0
77.0
79.0
82.0
84.0
86.0
86.5
88.0
89.5
90.0
91.0
91.7
92.3
92.8
93.6
62.0
64.0
62.0
65.0
65.0
70.0
72.0
77.0
80.0
82.0
84.0
86.0
86.5
88.0
89.5
90.2
91.2
91.7
92.3
92.8
93.6
0.81
0.83
0.82
0.82
0.82
0.82
0.86
0.87
0.85
0.85
0.85
0.86
0.89
0.89
0.88
0.90
0.91
0.88
0.89
0.89
0.89
0.26
0.32
0.50
0.68
1.00
1.36
1.73
2.40
3.25
4.55
6.10
7.80
10.4
13.8
20.0
26.5
32.0
39.5 1)
53.0
65.0 1)
78.0 1)
0.30
0.41
0.61
0.84
1.3
1.9
2.5
3.7
5.0
7.3
9.9
13
18
24
36
49
60
71
97
120
145
2.0
2.1
2.0
2.0
2.3
2.5
2.3
2.6
2.4
2.8
2.8
2.6
2.0
2.3
2.1
2.2
2.4
2.5
2.4
2.4
2.8
3.7
3.7
3.7
4.0
3.5
4.3
5.6
6.1
5.5
6.3
6.8
7.2
5.9
6.9
6.5
6.6
7.0
6.9
7.2
7.7
7.7
2.3
2.4
2.2
2.2
2.3
2.6
2.4
2.7
2.7
3.1
3.0
2.9
2.8
3.0
2.9
3.0
3.1
3.2
2.8
2.8
3.4
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
0.00015
0.00015
0.00018
0.00022
0.00029
0.00041
0.00079
0.0010
0.0014
0.0018
0.0035
0.0059
0.015
0.019
0.034
0.043
0.051
0.077
0.14
0.16
0.20
3
3
4
4
5
6
9
11
13
16
22
29
39
48
68
77
86
113
159
179
209
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1350
1350
1350
1350
1350
1370
1395
1395
1415
1420
1420
1420
1440
1455
1455
1460
1460
1460
1460
1465
1470
1470
56.0
58.0
55.0
60.0
60.0
65.0
67.0
72.0
77.0
79.0
82.0
83.0
85.0
86.0
87.0
88.5
90.0
90.5
91.2
91.8
92.9
93.4
55.0
57.0
54.0
60.0
60.0
65.0
67.0
72.0
77.0
79.0
82.5
83.5
85.5
86.0
87.5
89.0
90.2
90.5
91.2
91.8
92.9
93.4
0.77
0.77
0.75
0.77
0.78
0.78
0.82
0.81
0.81
0.81
0.82
0.82
0.83
0.81
0.82
0.84
0.84
0.83
0.84
0.86
0.87
0.87
0.20
0.29
0.42
0.56
0.77
1.06
1.44
1.86
2.55
3.40
4.70
6.40
8.20
11.4
15.2
21.5
28.5
35.5 1)
41.5 1)
55.0
66.0 1)
80.0 1)
0.42
0.64
0.85
1.3
1.8
2.6
3.8
5.1
7.4
10
15
20
27
36
49
72
98
121
144
196
240
292
1.9
1.9
1.9
1.9
1.9
1.9
2.2
2.3
2.3
2.4
2.5
2.7
2.7
2.5
2.7
2.2
2.6
2.3
2.3
2.6
2.8
2.8
2.6
2.6
2.8
3.0
3.0
3.3
3.9
4.2
4.6
5.3
5.6
5.6
6.0
6.3
6.7
6.2
6.5
7.5
7.5
7.0
7.0
7.7
1.9
1.9
2.0
1.9
1.9
2.1
2.2
2.3
2.4
2.6
2.8
3.0
3.0
3.1
3.2
2.7
3.0
3.0
3.0
3.2
3.2
3.3
13
13
13
13
13
13
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
0.00027
0.00027
0.00029
0.00037
0.00052
0.00077
0.0014
0.0017
0.0024
0.0033
0.0047
0.0055
0.012
0.018
0.023
0.043
0.055
0.13
0.15
0.24
0.32
0.36
3
3
4
4
5
6
9
10
13
16
21
24
31
41
49
73
85
113
123
157
206
232
56 M
63 M
71 M
80 M
90 S
90 L
100 L
112 M
132 S
132 M
160 M
160 L
180 M
180 L
200 L
225 S
225 M
1LA7 0504AB . .
1LA7 0534AB . .
1LA7 0604AB . .
1LA7 0634AB . .
1LA7 0704AB . .
1LA7 0734AB . .
1LA7 0804AA . .
1LA7 0834AA . .
1LA7 0904AA . .
1LA7 0964AA . .
1LA7 1064AA . .
1LA7 1074AA . .
1LA7 1134AA . .
1LA7 1304AA . .
1LA7 1334AA . .
1LA7 1634AA . .
1LA7 1664AA . .
1LA5 1834AA . .
1LA5 1864AA . .
1LA5 2074AA . .
1LA5 2204AA . .
1LA5 2234AA . .
Higher outputs under "1LA/1LG Cast iron housing" on Pages 3/12 and 3/13.
1
1
1
6
6
6
3
3
3
5
5
(Outputs at 60 Hz see
"Technical information")
1
6
1
6
1
6
3/2
Siemens M 11 2003/2004
IM B 35
6
6
6
Squirrel-cage motors
kW
Order No.
Operating data at rated output
Order No.
Rated Efficiency
Power
supplement for volt- speed h
factor
age and type of conp.f.
at
struction, see table
below
4/43/4load
rpm
%
%
Rated Rated
current torque
at 400 V
Starting
torque
Stalling
torque
Starting
current
current
torque
Nm
KL
kg m2
approx.
kg
63 M
71 M
80 M
90 S
90 L
100 L
112 M
132 S
132 M
132 M
160 M
160 L
180 L
200 L
225 M
1LA7 0636AB . .
1LA7 0706AA . .
1LA7 0736AA . .
1LA7 0806AA . .
1LA7 0836AA . .
1LA7 0906AA . .
1LA7 0966AA . .
1LA7 1066AA . .
1LA7 1136AA . .
1LA7 1306AA . .
1LA7 1336AA . .
1LA7 1346AA . .
1LA7 1636AA . .
1LA7 1666AA . .
1LA5 1866AA . .
1LA5 2066AA . .
1LA5 2076AA . .
1LA5 2236AA . .
850
850
860
920
910
915
915
925
940
950
950
950
960
960
970
975
975
978
45.0
53.0
60.0
62.0
67.0
69.0
72.0
74.0
78.0
79.0
80.5
83.0
86.0
87.5
89.5
90.2
90.8
91.8
41.5
54.5
58.5
60.5
66.5
69.0
72.0
74.0
78.5
79.5
80.5
83.0
86.0
87.5
89.5
90.2
90.8
91.8
0.66
0.73
0.76
0.72
0.74
0.76
0.77
0.75
0.78
0.76
0.76
0.76
0.74
0.74
0.77
0.77
0.77
0.77
0.44
0.67
0.79
1.20
1.60
2.05
2.85
3.90
5.20
7.20
9.40
12.6
17.0
24.5
31.5
38.5
45.5
61.0 1)
1.0
2.0
2.8
3.8
5.8
7.8
11
15
22
30
40
55
75
109
148
181
215
293
1.8
2.1
2.2
1.9
2.1
2.2
2.3
2.3
2.2
1.9
2.1
2.3
2.1
2.3
2.0
2.7
2.8
2.8
2.0
2.3
2.7
3.1
3.4
3.7
3.8
4.0
4.6
4.2
4.5
5.0
4.6
4.8
5.2
5.5
5.5
5.7
1.9
1.9
2.0
2.1
2.2
2.2
2.3
2.3
2.5
2.2
2.4
2.6
2.5
2.6
2.4
2.8
2.9
2.9
13
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
0.00037
0.00055
0.00080
0.0014
0.0017
0.0024
0.0033
0.0047
0.0091
0.015
0.019
0.025
0.044
0.063
0.15
0.24
0.28
0.36
4
5
6
9
10
13
16
21
26
38
44
52
74
95
126
161
183
214
630
645
675
685
675
675
680
680
705
700
700
715
710
715
725
725
725
725
53.0
53.0
51.0
55.0
63.0
66.0
66.0
72.0
74.0
75.0
77.0
80.0
83.5
85.5
87.0
87.5
89.2
90.6
54.5
49.5
49.5
50.5
62.0
65.0
65.0
72.0
74.0
75.0
77.5
80.0
83.5
85.5
87.0
87.5
89.2
90.6
0.68
0.64
0.68
0.64
0.75
0.76
0.76
0.76
0.76
0.74
0.74
0.72
0.73
0.72
0.75
0.78
0.79
0.79
0.36
0.51
0.75
1.02
1.14
1.58
2.15
2.90
3.85
5.70
7.60
10.0
13.0
17.6
24.5
31.5
38.0
44.5
1.4
1.8
2.5
3.5
5.2
7.8
11
15
20
30
41
53
74
100
145
198
244
290
1.9
2.2
1.7
2.0
1.6
1.7
1.6
1.8
1.8
1.9
2.1
2.2
2.3
2.7
2.0
2.1
2.1
2.2
2.2
2.2
2.3
2.6
2.9
3.0
3.0
3.3
3.7
3.9
4.1
4.5
4.7
5.3
5.0
5.0
4.5
4.8
1.7
2.0
1.9
2.2
1.8
1.9
1.9
2.1
2.1
2.3
2.4
2.6
2.7
3.0
2.2
2.2
2.2
2.3
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
0.00080
0.00080
0.0014
0.0017
0.0023
0.0031
0.0051
0.0063
0.013
0.014
0.019
0.036
0.046
0.064
0.21
0.37
0.37
0.45
6
6
9
10
11
13
19
22
24
38
44
64
74
94
128
176
184
214
71 M
80 M
90 S
90 L
100 L
112 M
132 S
132 M
160 M
160 M
160 L
180 L
200 L
225 S
225 M
1LA7 0708AB . .
1LA7 0738AB . .
1LA7 0808AB . .
1LA7 0838AB . .
1LA7 0908AB . .
1LA7 0968AB . .
1LA7 1068AB . .
1LA7 1078AB . .
1LA7 1138AB . .
1LA7 1308AB . .
1LA7 1338AB . .
1LA7 1638AB . .
1LA7 1648AB . .
1LA7 1668AB . .
1LA5 1868AB . .
1LA5 2078AB . .
1LA5 2208AB . .
1LA5 2238AB . .
Higher outputs under "1LA/1LG Cast iron housings" on Pages 3/14 and 3/15.
1
1
1
6
6
6
3
3
3
5
5
(Outputs at 60 Hz see
"Technical information")
1
6
1
6
1
6
IM B 35
6
6
6
3/3
Squirrel-cage motors
Order No.
Efficiency
Order No.
supplement for volt- class
age and type of construction, see table
below
rpm
kW
4/4- 3/4load
%
%
Starting
torque
Stalling
torque
Starting
current
current
torque
Nm
kg m2
kg
Energy-saving motor to CEMEP "High Efficiency" eff1, IP55 degree of protection, temperature class F
3000 rpm, 2-pole, 50 Hz
0.09
0.12
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
56 M
63 M
71 M
80 M
90 S
90 L
100 L
112 M
132 S
160 M
160 M
160 L
180 M
200 L
1LA9 0502KA . .
1LA9 0532KA . .
1LA9 0602KA . .
1LA9 0632KA . .
1LA9 0702KA . .
1LA9 0732KA . .
1LA9 0802KA . .
1LA9 0832KA . .
1LA9 0902KA . .
1LA9 0962KA . .
1LA9 1062KA . .
1LA9 1132KA . .
1LA9 1302KA . .
1LA9 1312KA . .
1LA9 1632KA . .
1LA9 1642KA . .
1LA9 1662KA . .
1LA9 1832WA . .
1LA9 2062WA . .
1LA9 2072WA . .
1
1
1
1
1
1
1
1
1
1
1
1
1
2830
2830
2840
2830
2840
2835
2870
2860
2890
2890
2890
2905
2930
2930
2945
2945
2940
2945
2950
2950
68.0
69.0
70.0
70.0
74.0
75.0
80.0
84.0
85.0
86.5
87.0
88.5
89.5
90.5
91.0
91.5
92.3
93.0
93.5
94.0
68.0
69.0
70.0
70.0
74.0
75.0
80.0
84.0
85.0
86.5
87.0
88.5
89.5
90.5
91.0
91.5
92.5
93.2
93.5
94.1
0.79
0.81
0.78
0.82
0.77
0.75
0.84
0.89
0.87
0.87
0.88
0.89
0.90
0.92
0.90
0.90
0.92
0.89
0.89
0.89
0.24
0.31
0.48
0.63
0.94
1.42
1.65
2.15
2.95
4.25
5.70
7.40
9.90
13.0
19.4
26.3
31.5
38.0 1)
52.0
64.0 1)
0.30
0.40
0.61
0.84
1.2
1.9
2.5
3.7
5.0
7.3
9.9
13
18
24
36
49
60
71
97
120
2.9
2.6
2.5
2.3
3.1
3.0
3.5
3.2
3.5
3.5
3.1
2.6
2.4
2.5
2.3
2.3
2.3
2.5
2.4
2.4
4.5
4.3
4.8
4.9
6.5
6.3
8.3
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.2
7.0
7.0
3.0
2.8
3.1
2.5
3.1
2.9
3.2
3.2
3.5
3.5
3.2
3.2
3.2
3.1
3.1
3.1
3.1
3.3
3.2
3.3
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
0.00015
0.00020
0.00022
0.00026
0.00041
0.00050
0.0010
0.0013
0.0018
0.0022
0.0044
0.0077
0.019
0.024
0.044
0.051
0.065
0.090
0.16
0.20
3
4
4
5
6
7
10
12
15
18
24
35
43
56
73
82
102
131
185
214
1
1
1
1
1
1
1
1
1
1
1
1
1380
1390
1395
1340
1410
1385
1410
1400
1440
1440
1435
1435
1440
1455
1455
1460
1460
1465
1465
1465
61.0
62.0
66.0
62.0
70.0
71.0
77.0
81.0
84.0
85.0
86.5
87.5
88.5
89.5
90.3
91.5
92.0
92.5
93.0
93.5
61.0
62.0
66.0
62.0
70.0
71.0
77.0
81.0
84.0
85.0
86.5
87.7
89.0
89.5
90.5
92.0
92.3
93.0
93.4
94.0
0.66
0.68
0.65
0.68
0.64
0.73
0.78
0.75
0.77
0.77
0.82
0.81
0.81
0.84
0.84
0.85
0.86
0.84
0.84
0.87
0.22
0.31
0.41
0.62
0.81
1.03
1.32
1.80
2.45
3.30
4.55
6.10
8.10
10.6
14.3
20.5
27.5
34.5 1)
40.5 1)
53.0
0.42
0.62
0.82
1.3
1.7
2.6
3.7
5.1
7.3
9.9
15
20
27
36
49
72
98
121
143
196
2.7
2.7
2.6
2.9
3.2
2.8
2.8
3.6
2.7
3.1
3.1
3.5
2.8
2.9
3.0
2.7
2.9
2.5
2.6
2.6
3.1
3.2
3.5
3.2
4.3
4.2
5.6
5.8
6.4
6.7
7.0
7.0
6.9
7.0
7.0
6.9
7.0
7.0
7.3
7.0
2.8
2.8
2.6
2.5
3.1
3.0
2.9
3.5
3.2
3.4
3.6
3.9
3.2
3.6
3.6
3.2
3.3
3.2
3.4
3.2
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
0.00027
0.00035
0.00037
0.00045
0.00076
0.00095
0.0017
0.0024
0.0033
0.0040
0.0062
0.0077
0.014
0.023
0.029
0.055
0.072
0.15
0.19
0.32
3
4
4
5
6
7
10
12
15
18
25
30
37
45
60
81
107
126
146
199
56 M
63 M
71 M
80 M
90 S
90 L
100 L
112 M
132 S
132 M
160 M
160 L
180 M
180 L
200 L
1LA9 0504KA . .
1LA9 0534KA . .
1LA9 0604KA . .
1LA9 0634KA . .
1LA9 0704KA . .
1LA9 0734KA . .
1LA9 0804KA . .
1LA9 0834KA . .
1LA9 0904KA . .
1LA9 0964KA . .
1LA9 1064KA . .
1LA9 1074KA . .
1LA9 1134KA . .
1LA9 1304KA . .
1LA9 1334KA . .
1LA9 1634KA . .
1LA9 1664KA . .
1LA9 1834WA . .
1LA9 1864WA . .
1LA9 2074WA . .
3/4
Siemens M 11 2003/2004
Squirrel-cage motors
Order No.
Efficiency
Order No.
supplement for volt- class
age and type of construction, see table
below
rpm
kW
4/4- 3/4load
%
%
Starting
torque
Stalling
torque
Starting
current
current
torque
Nm
kg m2
kg
90 S
90 L
100 L
112 M
132 M
160 M
160 L
180 L
200 L
925
940
950
955
950
960
965
960
970
975
975
1LA9 0906KA . .
1LA9 0966KA . .
1LA9 1066KA . .
1LA9 1136KA . .
1LA9 1336KA . .
1LA9 1346KA . .
1LA9 1636KA . .
1LA9 1666KA . .
1LA9 1866WA . .
1LA9 2066WA . .
1LA9 2076WA . .
75.5
82.0
85.0
84.0
84.0
86.0
88.0
88.5
91.0
91.0
91.5
75.5
82.0
85.0
84.0
84.0
86.0
88.0
88.5
91.0
91.0
91.5
0.72
0.70
0.70
0.70
0.81
0.77
0.72
0.78
0.75
0.77
0.77
2.00
2.80
3.65
5.40
8.50
12.0
17.1
23.0
31.5
38.0
45.0
7.7
11
15
22
40
55
74
109
148
181
215
2.5
3.2
3.4
2.7
2.5
3.3
2.2
2.9
2.0
2.5
2.5
4.4
5.7
6.2
6.2
6.3
7.3
5.5
6.9
6.5
6.2
6.2
2.5
3.2
3.4
3.0
2.7
3.6
2.5
3.2
2.5
2.5
2.5
16
16
16
16
16
16
16
16
16
16
16
0.0033
0.0050
0.0065
0.014
0.025
0.030
0.063
0.072
0.19
0.28
0.36
16
19
25
37
49
64
98
105
144
186
217
1
1
1
6
6
6
3
3
3
5
5
1
1
1
6
6
6
IM B 35
6
6
6
Siemens M 11 2003/2004
3/5
Squirrel-cage motors
Rated Size
output
Order No.
Operating data at rated output
Order No.
Rated
Nominal
Power Rated
Rated
supplement for volt- speed efficiency factor
current torque
age and type of conp.f.
at 460 V
struction, see table
below
rpm
HP
Starting
torque
Starting
current
Stalling
torque
current
torque
Nm
CC 032A
56 M
63 M
71 M
80 M
90 S
90 L
100 L
112 M
132 S
160 M
160 M
160 L
180 M
200 L
1LA9 0502KA . .
1LA9 0532KA . .
1LA9 0602KA . .
1LA9 0632KA . .
1LA9 0702KA . .
1LA9 0732KA . .
1LA9 0802KA . .
1LA9 0832KA . .
1LA9 0902KA . .
1LA9 0962KA . .
1LA9 1062KA . .
1LA9 1132KA . .
1LA9 1302KA . .
1LA9 1312KA . .
1LA9 1632KA . .
1LA9 1642KA . .
1LA9 1662KA . .
1LA9 1832WA . .
1LA9 2062WA . .
1LA9 2072WA . .
3440
3440
3440
3430
3445
3445
3485
3480
3510
3510
3510
3525
3540
3540
3555
3555
3550
3545
3555
3555
70.0
71.0
71.0
72.0
72.0
73.0
75.5
82.5
84.0
85.5
86.5
87.5
88.5
89.5
90.2
90.2
91.0
91.0
91.7
92.4
0.74
0.76
0.79
0.83
0.75
0.73
0.82
0.88
0.86
0.85
0.87
0.88
0.90
0.92
0.90
0.90
0.92
0.86
0.88
0.88
0.22
0.28
0.43
0.52
0.87
1.32
1.52
1.94
2.60
3.85
4.95
6.10
8.80
11.4
17.2
23.0
28.0
36.0
46.5
58.0
0.25
0.33
0.53
0.69
1.00
1.60
2.00
3.10
4.10
6.10
8.10
10
15
20
30
40
50
60
80
100
3.6
3.2
2.8
2.5
3.3
3.6
4.4
3.8
4.1
4.1
3.4
2.8
2.7
2.8
2.5
2.5
2.4
2.6
2.5
2.7
5.5
5.4
4.9
5.0
7.5
7.2
9.6
8.6
8.6
8.5
8.6
9.2
8.5
8.3
8.5
8.5
8.5
8.6
8.4
8.4
3.8
3.4
3.3
2.7
3.4
3.7
4.4
3.2
4.1
5.1
3.7
4.0
3.8
3.7
3.7
3.7
3.5
3.5
3.6
3.7
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
0.00015
0.00020
0.00022
0.00026
0.00041
0.00050
0.0010
0.0013
0.0018
0.0022
0.0044
0.0077
0.019
0.024
0.044
0.051
0.065
0.090
0.16
0.2
3
4
4
5
6
7
10
12
15
18
24
35
43
56
73
82
102
131
182
211
1715
1725
1720
1660
1730
1725
1725
1720
1755
1755
1750
1750
1755
1760
1760
1765
1765
1770
1770
1770
63.0
64.0
69.0
65.0
69.0
70.0
75.5
82.5
84.0
84.0
87.5
87.5
87.5
89.5
89.5
91.0
91.0
92.4
92.4
93.0
0.65
0.67
0.65
0.67
0.60
0.68
0.74
0.72
0.76
0.76
0.79
0.79
0.79
0.81
0.82
0.85
0.85
0.83
0.83
0.86
0.18
0.26
0.34
0.54
0.75
0.98
1.26
1.58
2.20
2.95
4.05
5.40
6.80
9.70
12.8
18.2
24.0
30.5
36.5
47.0
0.33
0.50
0.66
1.1
1.4
2.1
3.1
4.1
6.1
8.1
12
16
20
30
40
61
81
101
121
161
2.7
2.8
2.7
3.0
3.6
3.3
3.4
4.0
3.1
3.6
3.4
3.8
3.2
3.2
3.4
2.6
2.8
2.8
3.1
3.0
3.4
3.5
3.9
3.6
4.9
4.9
6.8
7.3
7.7
8.1
8.4
8.7
8.6
8.7
8.7
8.1
8.5
8.4
8.8
8.3
3.0
3.0
2.8
3.1
3.4
3.4
3.6
3.9
3.9
4.2
4.3
4.6
3.9
4.1
4.1
3.2
3.5
3.6
3.9
3.6
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
0.00027
0.00035
0.00037
0.00045
0.00076
0.00095
0.0017
0.0024
0.0033
0.0040
0.0062
0.0077
0.014
0.023
0.029
0.055
0.072
0.15
0.19
0.32
3
4
4
5
6
7
10
12
15
18
25
30
37
45
60
81
107
126
146
196
56 M
63 M
71 M
80 M
90 S
90 L
100 L
112 M
132 S
132 M
160 M
160 L
180 M
180 L
200 L
1LA9 0504KA . .
1LA9 0534KA . .
1LA9 0604KA . .
1LA9 0634KA . .
1LA9 0704KA . .
1LA9 0734KA . .
1LA9 0804KA . .
1LA9 0834KA . .
1LA9 0904KA . .
1LA9 0964KA . .
1LA9 1064KA . .
1LA9 1074KA . .
1LA9 1134KA . .
1LA9 1304KA . .
1LA9 1334KA . .
1LA9 1634KA . .
1LA9 1664KA . .
1LA9 1834WA . .
1LA9 1864WA . .
1LA9 2074WA . .
3/6
Siemens M 11 2003/2004
Squirrel-cage motors
Order No.
Operating data at rated output
Order No.
Rated
Nominal
Power Rated
Rated
supplement for volt- speed efficiency factor
current torque
age and type of conp.f.
at 460 V
struction, see table
below
rpm
HP
Starting
torque
Starting
current
Stalling
torque
current
torque
Nm
CC 032A
90 S
90 L
100 L
112 M
132 M
132 M
160 M
160 L
180 L
200 L
1LA9 0906KA . .
1LA9 0966KA . .
1LA9 1066KA . .
1LA9 1136KA . .
1LA9 1336KA . .
1LA9 1346KA . .
1LA9 1636KA . .
1LA9 1666KA . .
1LA9 1866WA . .
1LA9 2066WA . .
1LA9 2076WA . .
1140
1150
1160
1160
1160
1160
1165
1165
1175
1175
1175
80.0
85.5
86.5
87.5
87.5
89.5
89.5
90.2
90.2
91.7
91.7
0.66
0.64
0.68
0.66
0.77
0.73
0.70
0.77
0.75
0.75
0.75
1.78
2.55
3.20
4.85
6.90
10.8
15.0
20.0
27.5
34.0
41.0
6.2
9.3
12
18
31
46
61
92
121
152
182
3.0
3.7
3.5
2.9
3.0
3.7
2.4
3.1
2.2
2.8
2.8
5.6
6.4
7.2
7.5
7.9
8.4
6.4
8.3
7.1
7.1
7.2
3.0
3.7
3.8
3.7
3.6
4.3
2.8
3.8
2.8
2.8
2.8
16
16
16
16
16
16
16
16
16
16
16
0.0033
0.0050
0.0065
0.014
0.025
0.034
0.063
0.072
0.19
0.28
0.36
16
19
25
37
49
64
98
105
144
183
214
1
1
1
6
6
6
3
3
3
5
5
1
1
1
6
6
6
IM B 35
6
6
6
Siemens M 11 2003/2004
3/7
Squirrel-cage motors
Order No.
Operating data at rated output
Order No.
Rated Efficiency Power Rated Rated
supplement for volt- speed
factor
current torque
h
age and type of conp.f.
at 400 V
struction, see table
below
rpm
kW
Starting
torque
Starting
current
Stalling
torque
current
torque
Nm
56 M
63 M
71 M
80 M
90 S
90 L
100 L
112 M
132 S
160 M
160 M
160 L
180 M
200 L
1LA9 0532LA . .
1LA9 0602LA . .
1LA9 0632LA . .
1LA9 0702LA . .
1LA9 0732LA . .
1LA9 0802LA . .
1LA9 0832LA . .
1LA9 0902LA . .
1LA9 0962LA . .
1LA9 1062LA . .
1LA9 1132LA . .
1LA9 1302LA . .
1LA9 1312LA . .
1LA9 1632LA . .
1LA9 1642LA . .
1LA9 1662LA . .
1LA9 1832AA . .
1LA9 2062AA . .
1LA9 2072AA . .
2830
2775
2720
2720
2735
2820
2840
2825
2810
2880
2900
2915
2915
2920
2930
2935
2940
2945
2945
69.0
68.0
68.0
72.0
73.0
76.0
77.0
81.0
81.0
82.0
85.0
87.0
87.0
89.0
90.0
91.0
92.0
92.0
92.5
0.82
0.80
0.84
0.83
0.82
0.83
0.82
0.82
0.85
0.83
0.83
0.90
0.89
0.87
0.91
0.91
0.86
0.86
0.87
0.51
0.88
1.14
1.56
2.25
3.30
4.00
6.30
8.00
9.30
13.2
16.6
22.5
33.5
37.0
45.5
60.0
80.0
95.0
0.67
1.1
1.6
2.3
3.3
4.9
5.9
9.8
13
15
21
29
39
59
68
85
107
143
172
2.1
2.3
2.2
2.4
2.5
3.1
3.7
3.2
3.1
3.0
3.0
2.0
3.0
2.2
2.0
2.2
2.5
2.4
2.6
4.5
4.4
4.2
4.5
4.8
6.7
7.4
6.5
6.5
7.8
8.6
6.4
7.4
7.0
6.9
7.7
7.4
7.8
8.2
2.3
2.2
2.3
2.5
2.4
3.1
3.5
3.0
2.7
3.2
3.8
2.6
3.2
3.1
2.7
3.2
3.3
3.2
3.3
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
0.00020
0.00022
0.00026
0.00041
0.00050
0.0010
0.0013
0.0018
0.0022
0.0044
0.0077
0.019
0.024
0.044
0.051
0.065
0.090
0.16
0.20
4
4
5
6
7
10
12
15
18
24
35
43
56
73
82
102
131
182
211
1385
1335
1330
1340
1340
1340
1340
1380
1390
1410
1440
1440
1450
1455
1455
1460
1465
1465
62.0
60.0
60.0
64.0
70.0
70.0
70.0
77.0
76.0
77.0
82.0
84.0
85.0
88.0
88.0
90.5
91.3
91.7
0.74
0.77
0.71
0.71
0.75
0.81
0.83
0.83
0.81
0.81
0.80
0.83
0.83
0.84
0.82
0.83
0.84
0.85
0.44
0.66
0.98
1.42
1.64
2.30
3.10
4.05
5.90
9.30
12.2
17.8
22.5
33.0
44.0
50.0
60.0
80.0
0.97
1.5
2.1
3.2
4.3
6.4
8.9
12
17
27
36
57
72
112
144
170
209
280
2.3
2.1
2.3
2.3
2.3
2.3
2.7
2.4
2.5
2.7
3.0
2.3
2.8
2.9
3.1
2.4
2.5
2.7
3.5
2.9
2.9
3.4
3.6
4.1
4.5
5.1
5.1
6.0
6.8
6.8
7.4
7.5
8.3
7.5
7.9
7.8
2.2
2.1
2.3
2.3
2.3
2.4
2.4
2.4
2.3
3.0
3.0
2.7
3.1
2.8
3.4
3.2
3.4
3.5
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
0.00035
0.00037
0.00045
0.00076
0.00095
0.0017
0.0024
0.0033
0.0040
0.0062
0.014
0.023
0.029
0.055
0.072
0.15
0.19
0.32
4
4
5
6
7
10
12
15
18
25
37
45
60
81
107
126
146
196
56 M
63 M
71 M
80 M
90 S
90 L
100 L
112 M
132 S
132 M
160 M
160 L
180 M
180 L
200 L
1LA9 0534LA . .
1LA9 0604LA . .
1LA9 0634LA . .
1LA9 0704LA . .
1LA9 0734LA . .
1LA9 0804LA . .
1LA9 0834LA . .
1LA9 0904LA . .
1LA9 0964LA . .
1LA9 1074LA . .
1LA9 1134LA . .
1LA9 1304LA . .
1LA9 1334LA . .
1LA9 1634LA . .
1LA9 1664LA . .
1LA9 1834AA . .
1LA9 1864AA . .
1LA9 2074AA . .
1
1
1
6
6
6
3
3
3
5
5
1
1
1
3/8
Siemens M 11 2003/2004
6
6
6
IM B 35
6
6
6
Squirrel-cage motors
Rated
output
1500
rpm
kW
Size
3000
rpm
kW
highest speed.
Order No.
Stalling
torque
Torque
class
torque
1500
rpm
Moment Weight
of
inertia
Type of
J
constr.
IM B 3
3000
rpm
approx.
KL
kg m2
10
10
10
10
10
10
13
13
13
13
13
10
10
10
10
13
13
13
0.00029
4
0.00037
4
0.00052
5
0.00076
7
0.0014
9
0.0017
10
0.0024
13
0.0033
16
0.0048
21
0.0055
24
0.011
31
0.018
41
0.023
50
0.043
74
0.060
92
0.13
113
0.15
123
0.24
157
10
10
10
10
10
10
10
10
10
13
13
0.0023
0.0031
0.0051
0.0063
0.013
0.018
0.023
0.043
0.060
0.21
0.37
kg
0.15
0.2
0.28
0.43
0.6
0.85
1.4
1.9
2.4
3.1
4.4
5.9
8
11.5
17
18
21.5
31
750
rpm
1500
rpm
0.35
0.5
0.7
0.9
1.4
1.8
2.5
3.5
5.6
11
17
0.5
0.7
1.1
1.5
1.9
3.6
5
7
11
18
27
63 M
71 M
80 M
90 S
90 L
100 L
112 M
132 S
132 M
160 M
160 L
180 M
180 L
200 L
1LA7 0600AA . .
1LA7 0630AA . .
1LA7 0700AA . .
1LA7 0730AA . .
1LA7 0800AA . .
1LA7 0830AA . .
1LA7 0900AA . .
1LA7 0960AA . .
1LA7 1060AA . .
1LA7 1070AA . .
1LA7 1130AA . .
1LA7 1300AA . .
1LA7 1330AA . .
1LA7 1630AA . .
1LA7 1660AA . .
1LA5 1830AA . .
1LA5 1860AA . .
1LA5 2070AA . .
1330/2650
1330/2700
1375/2700
1380/2770
1390/2810
1390/2810
1390/2810
1390/2860
1410/2870
1400/2850
1420/2885
1450/2920
1450/2930
1455/2930
1455/2930
1470/2950
1465/2950
1465/2940
0.41
0.51
0.70
0.89
1.25
1.75
2.70
3.40
4.25
5.50
8.00
9.70
13.6
18.3
25.6
29.0
34.5
48.5
0.51
0.58
1.1
1.3
1.6
2.1
3.6
4.5
5.5
7.6
10.5
12.5
16.7
23.4
32.0
37.5
42.0
61.0
1.8
2.0
1.6
1.8
1.7
1.8
1.6
1.9
1.8
2.3
2.0
1.7
2.0
2.0
2.5
2.1
2.0
2.6
1.8
2.0
1.6
1.8
1.7
1.8
1.8
1.9
1.8
2.4
2.2
1.6
2.1
1.8
2.8
2.2
2.2
2.6
2.7
3.0
3.0
3.7
3.9
4.3
4.2
4.9
5.0
5.6
5.6
6.3
6.9
6.7
7.6
6.7
6.4
6.7
2.9
3.3
3.1
3.8
4.0
4.3
4.3
5.3
5.5
5.6
5.8
6.5
7.5
7.4
8.5
7.5
7.3
7.5
1.8
2.0
1.8
2.0
2.0
2.1
1.9
2.0
2.0
2.4
2.2
2.2
2.5
2.6
3.0
2.7
2.6
2.8
1.8
2.0
1.8
2.0
2.0
2.1
2.0
2.1
2.1
2.4
2.3
2.2
2.6
2.4
3.0
3.2
3.1
3.3
750
rpm
1500
rpm
750
rpm
1500
rpm
750
rpm
1500
rpm
750
rpm
1500
rpm
1.6
1.7
2.0
2.0
1.7
2.3
2.3
2.3
2.4
2.2
2.5
1.6
1.8
1.9
1.9
1.8
1.8
1.8
1.8
2.0
2.2
2.5
750/1500 rpm, 8-/4-pole, 50 Hz, version with one winding in Dahlander circuit
90 S
90 L
100 L
112 M
132 S
132 M
160 M
160 L
180 L
200 L
1LA7 0900AB . .
1LA7 0960AB . .
1LA7 1060AB . .
1LA7 1070AB . .
1LA7 1130AB . .
1LA7 1300AB . .
1LA7 1330AB . .
1LA7 1630AB . .
1LA7 1660AB . .
1LA5 1860AB . .
1LA5 2070AB . .
675/1365
675/1380
690/1380
680/1400
690/1410
720/1430
720/1430
725/1450
725/1450
725/1455
730/1465
1.19
1.60
2.10
2.50
4.00
6.30
8.20
11.7
18.5
27.0
40.5
1.41
2.10
3.25
3.65
5.20
7.20
10.0
13.9
21.15
35.0
50.5
1.3
1.4
1.7
1.8
1.4
2.0
2.0
2.0
2.2
1.9
2.4
1.3
1.5
1.6
1.6
1.5
1.3
1.3
1.4
1.7
2.0
2.3
2.5
3.0
3.3
3.5
3.6
4.3
4.3
4.0
4.2
5.2
5.4
3.2
3.5
3.5
3.6
4.4
5.4
5.4
5.4
5.9
6.2
6.6
11 13
20
22
25
41
49
73
91
123
157
1
1
6
6
5
5
0
0
IM B 14
With
special
flange
3
IM B 35
6
6
Siemens M 11 2003/2004
3/9
Squirrel-cage motors
1500
rpm
kW
Size
3000
rpm
kW
Order No.
Stalling
torque
Torque
class
torque
1500
rpm
Moment Weight
of
inertia
Type of
J
constr.
IM B 3
3000
rpm
approx.
KL
kg m2
kg
10
10
10
10
10
10
10
10
10
10
10
0.0014
0.0017
0.0024
0.0033
0.0048
0.0055
0.011
0.018
0.023
0.043
0.060
10
11
13
16
21
24
31
41
50
74
92
10
10
10
10
10
10
10
10
10
10
10
10
10
10
0.0014
0.0017
0.0027
0.0033
0.0049
0.0057
0.012
0.018
0.023
0.043
0.060
0.081
0.094
0.16
21
24
31
41
49
74
92
116
123
157
10
10
10
10
10
10
10
10
10
10
10
10
10
10
0.0014
0.0017
0.0024
0.0033
0.0047
0.0054
0.012
0.018
0.023
0.043
0.060
0.13
0.15
0.24
9
10
13
16
21
24
31
41
49
73
91
113
123
157
Two-speed pole-change for driving fans, IP55 degree of protection, temperature class F
1500/3000 rpm, 4-/2-pole, 50 Hz, version with one winding in Dahlander circuit
0.15
0.25
0.33
0.5
0.65
0.8
1.1
1.45
2
2.9
4.3
0.7
0.95
1.4
2
2.5
3.1
4.4
5.9
8
11.5
17
1000
rpm
1500
rpm
0.12
0.18
0.29
0.38
0.6
0.75
0.9
1.2
1.7
2.5
3.7
5.5
6.5
9.5
0.4
0.55
0.8
1.1
1.7
2.1
3
3.9
5.4
7.2
12
16
19
26
750
rpm
1500
rpm
0.1
0.15
0.22
0.33
0.5
0.65
0.9
1.1
1.4
2.2
3.3
4.5
5
7.5
0.5
0.7
1
1.5
2
2.5
3.6
4.7
6.4
9.5
14
16
18.5
28
80 M
90 S
90 L
100 L
112 M
132 S
132 M
160 M
160 L
1LA7 0800BA . .
1LA7 0830BA . .
1LA7 0900BA . .
1LA7 0960BA . .
1LA7 1060BA . .
1LA7 1070BA . .
1LA7 1130BA . .
1LA7 1300BA . .
1LA7 1330BA . .
1LA7 1630BA . .
1LA7 1660BA . .
1400/2745
1385/2780
1420/2835
1420/2835
1430/2865
1425/2860
1445/2885
1455/2920
1455/2930
1455/2930
1455/2930
0.39
0.61
0.76
1.08
1.44
1.70
2.50
3.00
4.00
5.70
8.40
1.76
2.40
3.50
4.80
5.40
7.00
10.7
12.8
16.0
22.0
31.0
1.8
1.8
1.9
2.2
1.7
1.8
2.1
2.0
1.9
1.8
1.9
1.6
1.9
1.8
2.2
2.2
2.3
2.2
2.1
2.1
1.8
2.2
3.8
3.8
4.5
5.1
5.0
5.7
6.2
6.8
7.6
6.9
7.1
4.0
4.2
4.3
5.0
5.5
6.1
6.2
6.5
7.5
7.4
8.5
2.0
2.0
2.1
2.5
2.3
2.6
2.4
2.8
2.6
2.5
2.5
2.0
2.0
2.0
2.5
2.3
2.6
2.4
2.8
2.6
2.4
2.6
1000
rpm
1500
rpm
1000
rpm
1500
rpm
1000
rpm
1500
rpm
1000
rpm
1500
rpm
1LA7 0801BD . .
1LA7 0831BD . .
1LA7 0901BD . .
1LA7 0961BD . .
1LA7 1061BD . .
1LA7 1071BD . .
1LA7 1131BD . .
1LA7 1301BD . .
1LA7 1331BD . .
1LA7 1631BD . .
1LA7 1661BD . .
1LA5 1831BD . .
1LA5 1861BD . .
1LA5 2071BD . .
940/1430
930/1420
950/1430
955/1430
950/1410
950/1420
980/1450
975/1460
975/1460
980/1470
980/1470
965/1470
965/1460
980/1470
0.51
0.73
1.07
1.33
1.75
2.30
3.00
3.50
4.55
6.4
9.3
11.8
13.8
20.0
1.38
1.62
2.10
2.65
3.80
4.55
6.70
8.40
11.4
14.4
23.3
31.5
36.5
49.0
1.7
1.5
1.5
1.8
1.8
1.6
2.0
1.9
2.1
1.9
1.9
1.8
1.8
1.9
1.7
1.7
1.5
1.8
1.8
1.9
2.1
1.7
1.9
2.0
2.4
1.9
1.9
1.5
2.8
2.5
3.4
3.8
4.2
3.9
4.5
5.1
5.1
5.6
5.7
4.3
4.3
5.3
4.0
4.0
4.3
4.9
5.2
5.2
6.1
6.1
6.6
7.3
8.1
5.9
5.6
5.5
1.8
1.8
2.0
2.3
2.2
2.0
2.5
2.5
2.6
1.9
2.3
1.9
2.1
2.1
2.0
2.0
2.0
2.3
2.2
2.2
2.5
2.2
2.5
2.0
3.0
2.6
2.6
2.1
750
rpm
1500
rpm
750
rpm
1500
rpm
750
rpm
1500
rpm
750
rpm
1500
rpm
1.7
1.7
1.8
1.8
1.8
1.8
2.4
2.5
2.7
2.0
2.2
2.1
2.1
2.2
1.8
1.8
2.0
2.0
2.1
2.1
2.6
2.9
2.5
2.6
3.1
2.9
2.7
2.5
9
10
13 16
750/1500 rpm, 8-/4-pole, 50 Hz, version with one winding in Dahlander circuit
80 M
90 S
90 L
100 L
112 M
132 S
132 M
160 M
160 L
180 M
180 L
200 L
1LA7 0800BB . .
1LA7 0830BB . .
1LA7 0900BB . .
1LA7 0960BB . .
1LA7 1060BB . .
1LA7 1070BB . .
1LA7 1130BB . .
1LA7 1300BB . .
1LA7 1330BB . .
1LA7 1630BB . .
1LA7 1660BB . .
1LA5 1830BB . .
1LA5 1860BB . .
1LA5 2070BB . .
680/1375
685/1380
695/1370
700/1375
710/1415
700/1400
720/1440
720/1455
720/1455
725/1465
730/1470
730/1470
730/1470
732/1470
0.57
0.77
1.25
1.80
2.50
2.80
4.70
3.30
4.40
6.50
9.30
13.6
15.0
20.5
1.28
1.76
2.40
3.30
4.30
5.30
8.00
10.3
13.3
19.7
28.6
32.3
36.5
52.0
1.4
1.4
1.3
1.5
1.1
1.1
1.6
2.0
2.2
1.7
2.0
1.4
1.5
1.9
1.7
1.8
1.5
1.8
1.9
1.9
2.6
2.3
1.9
2.0
2.6
2.3
2.3
2.5
2.3
2.4
2.4
2.6
3.1
3.1
3.2
4.3
4.6
4.1
4.7
3.8
3.8
4.3
4.1
4.2
3.7
4.2
5.2
5.4
6.5
6.4
6.8
7.0
8.1
7.0
7.0
7.1
1
1
6
6
5
5
0
0
3/10
Siemens M 11 2003/2004
IM B 14
With
special
flange
3
IM B 35
6
6
Squirrel-cage motors
750
rpm
kW
Size
1000
rpm
kW
Order No.
1500
rpm
kW
Starting
Starting
torque
current
For direct-on-line starting
as multiple of the rated
torque
current
1500
rpm
A
750
rpm
1000 1500
rpm rpm
750
rpm
1000 1500
rpm rpm
approx.
KL
kg m2
kg
Three-speed pole-change for driving fans, IP55 degree of protection, temperature class F
750/1000/1500 rpm, 8-/6-/4-pole, 50 Hz,
version with two windings, of which 750/1500 rpm in Dahlander circuit
0.15
0.22
0.37
0.45
0.6
0.75
1
1.6
2.4
3
3.7
5
0.22
0.3
0.55
0.7
0.85
1.1
1.5
2.2
3.5
4.5
5.5
8
0.7
0.95
1.5
1.8
2.4
3.1
4.4
6.6
10
13
16
22
90 S
90 L
100 L
112 M
132 S
132 M
160 M
160 L
180 M
180 L
200 L
1LA7 0901BJ . .
1LA7 0961BJ . .
1LA7 1061BJ . .
1LA7 1071BJ . .
1LA7 1131BJ . .
1LA7 1301BJ . .
1LA7 1331BJ . .
1LA7 1631BJ . .
1LA7 1661BJ . .
1LA5 1831BJ . .
1LA5 1861BJ . .
1LA5 2071BJ . .
1.74
2.30
3.25
3.90
5.10
7.20
9.70
14.2
20.7
25.5
31.0
42.0
1.3
1.3
0.9
0.9
1.1
1.7
1.8
1.4
1.6
1.2
1.1
1.2
1.3
1.3
1.4
1.4
1.3
1.7
1.9
1.7
1.8
1.8
1.9
1.9
1.5
1.4
1.5
1.7
1.9
1.5
1.6
1.7
2.0
1.3
1.3
1.3
2.5
2.5
2.8
2.8
3.1
3.7
3.9
3.9
4.1
3.2
3.2
3.6
2.9
3.1
3.8
3.8
4.4
4.5
4.9
5.1
5.3
5.0
5.0
5.0
4.3
4.0
4.7
4.7
6.0
5.5
5.8
7.0
7.7
5.4
5.4
5.4
10
10
7
7
7
10
10
7
7
7
7
7
0.0028
0.0035
0.0048
0.0058
0.011
0.018
0.024
0.040
0.054
0.081
0.094
0.16
12
15
20
22
29
39
46
67
85
116
123
157
1
1
6
6
5
5
0
0
IM B 14
With
special
flange
3
IM B 35
6
6
Siemens M 11 2003/2004
3/11
Squirrel-cage motors
kW
Order No.
EffiOperating data at rated output
ciency Rated Efficiency Power Rated
Order No.
Rated
supplement for volt- class speed h
factor current at torque
age and type of conp.f.
400 V
at
struction, see
table below
4/4- 3/4load
rpm
%
%
A
Nm
Starting
torque
Starting
current
Stalling
torque
current
torque
kg m2
kg
16
16
16
16
16
16
16
16
16
16
16
13
13
13
13
13
13
13
10
10
10
10
10
10
10
10
5
5
5
0.0035
0.0059
0.015
0.019
0.034
0.043
0.051
0.068
0.13
0.15
0.22
0.40
0.72
0.83
1.2
1.4
1.6
2.1
2.7
3.3
4.8
5.3
6.4
8.6
9.6
11
19
21
23
34
43
53
58
96
105
115
145
205
225
285
375
500
540
720
775
900
1015
1300
1500
1900
2000
2200
2800
3000
3200
4000
4200
4400
Energy-saving motor to CEMEP "Improved Efficiency" eff2, IP55 degree of protection, temperature class F
3000 rpm, 2-pole, 50 Hz
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
200
250
315
355
400
500
560
630
710
800
900
1000
100 L
112 M
132 S
160 M
160 M
160 L
180 M
200 L
225 M
250 M
280 S
280 M
315 S
315 M
315 L
315 L
315
355
400
450
1LA6 1062AA . .
1LA6 1132AA . .
1LA6 1302AA . .
1LA6 1312AA . .
1LA6 1632AA . .
1LA6 1642AA . .
1LA6 1662AA . .
1LG4 1832AA . .
1LG4 2062AA . .
1LG4 2072AA . .
1LG4 2232AA . .
1LG4 2532AB . .
1LG4 2802AB . .
1LG4 2832AB . .
1LG4 3102AB . .
1LG4 3132AB . .
1LG4 3162AB . .
1LG4 3172AB . .
1LA8 3152AC . .
1LA8 3172AC . .
1LA8 3532AC . . s
1LA8 3552AC . . s
1LA8 3572AC . . s
1LA8 4032AC . . s
1LA8 4052AC . . s
1LA8 4072AC . . s
1LA8 4532AE . . s
1LA8 4552AE . . s
1LA8 4572AE . . s
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2890
2905
2925
2930
2940
2940
2940
2945
2950
2955
2960
2970
2975
2975
2982
2982
2982
2982
2979
2979
2980
2980
2982
2985
2985
2985
2986
2986
2986
84.0
86.0
86.5
88.0
89.5
90.0
91.0
91.6
91.8
92.9
93.6
93.6
94.5
95.1
94.6
95.1
95.5
95.9
96.2
96.6
96.6
96.7
97.1
97.1
97.1
97.3
97.2
97.3
97.4
84.0
86.0
86.5
88.0
89.5
90.2
91.2
91.6
91.9
93.2
93.9
93.8
94.3
95.2
93.8
94.8
95.3
95.8
96.2
96.6
96.6
96.7
97.1
97.1
97.1
97.3
97.2
97.3
97.4
0.85
0.86
0.89
0.89
0.88
0.90
0.91
0.86
0.88
0.89
0.88
0.88
0.88
0.89
0.88
0.90
0.91
0.92
0.90
0.91
0.90
0.91
0.91
0.91
0.91
0.91
0.91
0.92
0.93
6.1
7.8
10.4
13.8
20.0
26.5
32.0
40.5
54.0
65.0
79.0
96.0
130
154
190
225
265
325
415
520
590
660
820
910
1020
670 V C
760 V
840 V
920 V
9.9
13
18
24
36
49
60
71
97
120
145
177
241
289
352
423
512
641
801
1010
1140
1280
1600
1790
2020
2270
2560
2880
3200
2.8
2.6
2.0
2.3
2.1
2.2
2.4
2.5
2.3
2.5
2.4
2.1
2.5
2.6
2.4
2.4
2.4
2.3
1.8
1.8
1.7
1.7
1.8
1.6
1.6
1.7
0.9
0.9
0.9
6.8
7.2
5.9
6.9
6.5
6.6
7.0
6.4
6.5
7.2
6.7
6.7
7.5
7.2
7.2
6.9
7.0
6.7
7.0
7.0
6.5
6.5
6.5
7.0
7.0
7.0
7.0
7.0
7.0
3.0
2.9
2.8
3.0
2.9
3.0
3.1
3.4
3.0
3.3
3.1
3.1
3.1
3.1
3.1
3.0
3.0
2.9
2.8
2.8
2.5
2.5
2.6
2.8
2.8
2.8
3.0
2.8
2.7
With axial fan for clockwise rotation. C Also supplied for 400 VD (voltage identifier "9" and order code L1Y).
1
6
0
1
1
4
2
3
1
6
3
5
1
6
0
1
1
4
6
0
8
4
9 L2F
0
8
4
5
0
On request
0
8
4
IM B 35
6
6
6
6
6
Parallel supply cables required (see "Technical information", "Connections, circuits and terminal blocks")
Voltage
1LG4
1LA8
183 206 207 223 253 280 283 310 313 316 317
315 317 353 355
230 V
400 V
500 V
690 V
3/12
Siemens M 11 2003/2004
357
403
405
407
453
455
457
Squirrel-cage motors
Order No.
EffiOperating data at rated output
ciency Rated Efficiency Power Rated
Order No.
Rated
supplement for volt- class speed h
factor current at torque
age and type of conp.f.
400 V
at
struction, see table
below
4/4- 3/4load
rpm
%
%
A
Nm
kW
Starting
torque
Starting
current
Stalling
torque
current
torque
KL
kg m2
kg
Energy-saving motor to CEMEP "Improved Efficiency" eff2, IP55 degree of protection, temperature class F
1500 rpm, 4-pole, 50 Hz
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
200
250
315
355
400
500
560
630
710
800
900
1000
100 L
112 M
132 S
132 M
160 M
160 L
180 M
180 L
200 L
225 S
225 M
250 M
280 S
280 M
315 S
315 M
315 L
315 L
315 s
s
355
s
s
400
450
1LA6 1064AA . .
1LA6 1074AA . .
1LA6 1134AA . .
1LA6 1304AA . .
1LA6 1334AA . .
1LA6 1634AA . .
1LA6 1664AA . .
1LG4 1834AA . .
1LG4 1864AA . .
1LG4 2074AA . .
1LG4 2204AA . .
1LG4 2234AA . .
1LG4 2534AA . .
1LG4 2804AA . .
1LG4 2834AA . .
1LG4 3104AA . .
1LG4 3134AA . .
1LG4 3164AA . .
1LG4 3174AA . .
1LA8 3154AB . .
1LA8 3174AB . .
1LA8 3534AB . .
1LA8 3554AB . .
1LA8 3574AB . .
1LA8 4034AB . .
1LA8 4054AB . .
1LA8 4074AB . .
1LA8 4534AC . .
1LA8 4554AC . .
1LA8 4574AC . .
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1420
1420
1440
1455
1455
1460
1460
1465
1465
1465
1475
1475
1480
1485
1485
1488
1488
1486
1486
1488
1488
1488
1488
1488
1492
1492
1492
1492
1492
1492
82.0
83.0
85.0
86.0
87.0
88.5
90.0
90.4
91.0
91.6
92.2
93.1
93.5
94.2
94.6
94.6
95.2
95.7
95.9
96.0
96.3
96.3
96.4
96.8
96.8
97.0
97.0
97.0
97.1
97.1
82.5
83.5
85.5
86.0
87.5
89.0
90.2
90.8
91.5
92.0
92.6
93.6
93.8
94.1
94.6
94.6
95.2
95.8
96.2
96.0
96.3
96.3
96.4
96.8
96.8
97.0
97.0
97.0
97.1
97.1
0.82
0.82
0.83
0.81
0.82
0.84
0.84
0.84
0.84
0.85
0.85
0.86
0.85
0.85
0.86
0.85
0.85
0.86
0.88
0.88
0.88
0.87
0.87
0.88
0.88
0.88
0.89
0.88
0.88
0.89
4.7
6.4
8.2
11.4
15.2
21.5
28.5
35.0
41.5
56.0
68.0
81.0
100
136
160
198
235
280
340
425
540
610
690
850
950
1060
690 V C
780 V C
880 V C
970 V
15
20
27
36
49
72
98
121
143
196
240
291
355
482
579
706
847
1028
1285
1600
2020
2280
2570
3210
3580
4030
4540
5120
5760
6400
2.5
2.7
2.7
2.5
2.7
2.2
2.6
2.4
2.5
2.5
2.5
2.7
2.4
2.5
2.5
2.5
2.7
2.7
2.6
1.9
2.0
2.1
2.1
2.1
1.9
1.9
1.9
1.6
1.6
1.7
5.6
5.6
6.0
6.3
6.7
6.2
6.5
6.7
6.9
6.7
6.7
7.2
6.1
7.1
7.4
6.4
6.8
6.8
6.5
6.5
6.8
6.5
6.5
6.5
6.5
6.8
6.8
7.0
7.0
7.0
2.8
3.0
3.0
3.1
3.2
2.7
3.0
3.1
3.2
3.4
3.1
3.2
2.8
3.0
3.0
2.8
2.9
2.8
2.8
2.8
2.8
2.6
2.6
2.4
2.7
2.7
2.7
2.6
2.6
2.6
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
13
13
13
13
13
13
13
13
10
10
10
0.0047
0.0055
0.012
0.018
0.023
0.043
0.055
0.099
0.12
0.19
0.37
0.45
0.69
1.2
1.4
1.9
2.3
2.9
3.5
3.6
4.4
6.1
6.8
8.5
13
14
16
23
26
28
33
36
45
55
62
100
114
140
155
205
265
300
390
535
580
730
810
955
1060
1300
1500
1900
2000
2200
2800
3000
3200
4000
4200
4400
C Also supplied for 400 VD (voltage identifier "9" and order code L1Y).
for 1LA8 motors is a standard offer for certain designs and can be ordered with Order Code B20. It decreases the price by 10% for the basic
machine. The delivery time is 4 weeks. Scope of supply for Standardline:
4-pole design
Types 1LA8 315, 1LA8 317, 1LA8 353 and 1LA8 355
Design designator 0 (IM B3)
Voltage distinctive number 6 (400 Vd/690 V*) or 5 (500 Vd)
Available for operation with converter, but not in 690 V design
Available Order No.: A12, A23, A61, A72, H70, H73, K09, K10, K45, L97, L98 and L27
1
6
0
1
1
4
2
3
1
6
3
5
1
6
0
1
1
4
6
0
8
4
9 L2F
0
8
4
5
0
On request
0
8
4
IM B 35
6
6
6
6
6
Parallel supply cables required (see "Technical information", "Connections, circuits and terminal blocks")
Voltage
1LG4
1LA8
183 186 207 220 223 253 280 283 310 313 316 317
315 317 353 355
230 V
400 V
500 V
690 V
357
403
405
407
453
455
457
Siemens M 11 2003/2004
3/13
Squirrel-cage motors
kW
Order No.
Operating data at rated output
Order No.
Rated Efficiency
Power
supplement for volt- speed h
factor
age and type of conp.f.
at
struction, see table
below
4/43/4load
rpm
%
%
Rated
Rated
current torque
at 400 V
Starting
torque
Stalling
torque
Starting
current
current
torque
Nm
kg m2
kg
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
13
13
13
13
13
13
13
13
13
13
0.0047
0.0091
0.015
0.019
0.025
0.044
0.063
0.18
0.24
0.29
0.49
0.76
1.10
1.40
2.1
2.5
3.2
4.0
4.7
6.0
7.3
13
16
21
24
27
35
39
44
33
40
50
57
66
103
122
150
195
205
280
370
475
510
685
750
890
980
1180
1300
1500
2000
2200
2800
3000
3200
4000
4200
4500
100 L
112 M
132 S
132 M
132 M
160 M
160 L
180 L
200 L
225 M
250 M
280 S
280 M
315 S
315 M
315 L
315 L
315 L
315
355
400
450
925
940
950
950
950
960
960
965
975
975
978
980
985
985
988
988
988
988
988
989
989
993
993
992
992
992
993
993
993
1LA6 1066AA . .
1LA6 1136AA . .
1LA6 1306AA . .
1LA6 1336AA . .
1LA6 1346AA . .
1LA6 1636AA . .
1LA6 1666AA . .
1LG4 1866AA . .
1LG4 2066AA . .
1LG4 2076AA . .
1LG4 2236AA . .
1LG4 2536AA . .
1LG4 2806AA . .
1LG4 2836AA . .
1LG4 3106AA . .
1LG4 3136AA . .
1LG4 3166AA . .
1LG4 3176AA . .
1LG4 3186AA . .
1LA8 3156AB . .
1LA8 3176AB . .
1LA8 3556AB . .
1LA8 3576AB . .
1LA8 4036AB . .
1LA8 4056AB . .
1LA8 4076AB . .
1LA8 4536AB . .
1LA8 4556AB . .
1LA8 4576AB . .
74.0
78.0
79.0
80.5
83.0
86.0
87.5
88.9
89.8
90.3
91.8
92.3
92.4
92.7
93.5
93.9
94.3
94.8
95.0
95.7
95.9
96.2
96.5
96.5
96.5
96.7
96.8
96.8
97.0
74.0
78.5
79.5
80.5
83.0
86.0
87.5
90.3
90.2
91.0
92.8
93.0
93.1
93.3
93.7
94.2
94.6
95.0
95.1
95.8
96.0
96.2
96.5
96.5
96.5
96.7
96.8
96.8
97.1
0.75
0.78
0.76
0.76
0.76
0.74
0.74
0.83
0.81
0.81
0.83
0.83
0.85
0.86
0.84
0.84
0.86
0.86
0.86
0.86
0.86
0.86
0.86
0.86
0.86
0.86
0.86
0.86
0.86
3.9
5.2
7.2
9.4
12.6
17.0
24.5
29.5
36.5
43.5
57.0
70.0
83.0
100
138
164
196
235
285
345
430
540
690
780
860
960
1100
710 V C
790 V C
15
22
30
40
55
75
109
148
181
215
293
361
436
533
725
870
1063
1276
1547
1930
2410
3030
3850
4330
4810
5390
6060
6830
7690
2.3
2.2
1.9
2.1
2.3
2.1
2.3
2.3
2.5
2.6
2.7
2.7
2.4
2.5
2.5
2.6
2.5
3.1
3.0
2.0
2.0
2.2
2.2
2.2
2.3
2.3
2.0
2.0
2.0
4.0
4.6
4.2
4.5
5.0
4.6
4.8
5.3
5.6
5.7
5.6
6.0
6.1
6.3
6.5
6.8
6.8
7.3
7.5
6.3
6.3
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
2.3
2.5
2.2
2.4
2.6
2.5
2.6
2.5
2.5
2.5
2.5
2.3
2.4
2.5
2.8
2.9
2.9
3.0
3.0
2.5
2.5
2.8
2.8
2.8
2.8
2.8
2.6
2.5
2.5
C Also supplied for 400 VD (voltage identifier "9" and order code L1Y).
1
6
0
1
1
4
2
3
1
6
3
5
1
6
0
1
1
4
6
0
8
4
9 L2F
0
8
4
5
0
On request
0
8
4
Siemens M 11 2003/2004
6
6
6
6
6
Parallel supply cables required (see "Technical information", "Connections, circuits and terminal blocks")
Voltage
1LG4
1LA8
186 206 207 223 253 280 283 310 313 316 317 318
315 317 355
230 V
400 V
500 V
3/14
IM B 35
357
403
405
407
453
455
457
Squirrel-cage motors
kW
Order No.
Operating data at rated output
Order No.
Rated Efficiency
Power
supplement for volt- speed h
factor
age and type of conp.f.
at
struction, see table
below
4/43/4load
rpm
%
%
Rated Rated
current torque
at 400 V
Starting
torque
Stalling
torque
Starting
current
current
torque
Nm
KL
kg m2
approx.
kg
100 L
112 M
132 S
132 M
160 M
160 M
160 L
180 L
200 L
225 S
225 M
250 M
280 S
280 M
315 S
315 M
315 L
315 L
315 L
315
355
400
450
1LA6 1068AB . .
1LA6 1078AB . .
1LA6 1138AB . .
1LA6 1308AB . .
1LA6 1338AB . .
1LA6 1638AB . .
1LA6 1648AB . .
1LA6 1668AB . .
1LG4 1868AB . .
1LG4 2078AB . .
1LG4 2208AB . .
1LG4 2238AB . .
1LG4 2538AB . .
1LG4 2808AB . .
1LG4 2838AB . .
1LG4 3108AB . .
1LG4 3138AB . .
1LG4 3168AB . .
1LG4 3178AB . .
1LG4 3188AB . .
1LA8 3158AB . .
1LA8 3178AB . .
1LA8 3558AB . .
1LA8 3578AB . .
1LA8 4038AB . .
1LA8 4058AB . .
1LA8 4078AB . .
1LA8 4538AB . .
1LA8 4558AB . .
1LA8 4578AB . .
680
680
705
700
700
715
710
715
725
725
730
730
730
735
735
740
738
738
738
738
739
739
741
741
742
742
742
744
744
744
66.0
72.0
74.0
75.0
77.0
80.0
83.5
85.5
87.5
87.7
89.4
89.7
91.4
92.0
92.4
93.0
93.3
93.4
94.0
94.2
94.9
95.2
95.7
96.0
96.1
96.2
96.3
96.4
96.5
96.6
65.0
72.0
74.0
75.0
77.5
80.0
83.5
85.5
88.3
88.4
90.4
90.7
92.2
92.8
93.3
93.4
94.0
94.0
94.4
94.6
95.1
95.6
96.0
96.0
96.2
96.4
96.3
96.4
96.4
96.6
0.76
0.76
0.76
0.74
0.74
0.72
0.73
0.72
0.73
0.76
0.78
0.79
0.81
0.81
0.81
0.81
0.83
0.83
0.83
0.83
0.82
0.82
0.82
0.82
0.82
0.82
0.82
0.81
0.81
0.81
2.15
2.90
3.85
5.70
7.60
10.0
13.0
17.6
25.0
32.5
38.5
45.0
58.0
72.0
87.0
106
140
168
205
245
295
370
460
580
650
730
820
920
1040
1160
11
15
20
30
41
53
74
100
145
198
242
288
392
481
585
710
971
1165
1423
1708
2070
2580
3220
4060
4570
5150
5790
6420
7190
8090
1.6
1.8
1.8
1.9
2.1
2.2
2.3
2.7
1.7
2.2
2.3
2.3
2.3
2.2
2.2
2.2
2.2
2.2
2.4
2.5
2.1
2.1
2.1
2.1
2.0
2.1
2.1
2.0
2.0
2.0
3.0
3.3
3.7
3.9
4.1
4.5
4.7
5.3
4.2
4.9
5.5
5.6
5.5
5.0
5.1
5.8
5.7
5.8
6.1
6.5
6.0
6.0
6.1
6.1
6.5
6.5
6.5
6.6
6.6
6.6
1.9
2.1
2.1
2.3
2.4
2.6
2.7
3.0
2.1
2.6
2.7
2.8
2.6
2.1
2.1
2.6
2.6
2.7
2.8
2.9
2.3
2.3
2.4
2.4
2.6
2.6
2.6
2.4
2.4
2.4
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
0.0051
0.0063
0.013
0.014
0.019
0.036
0.046
0.064
0.17
0.29
0.48
0.55
0.84
1.11
1.40
2.1
2.5
3.1
3.9
4.5
6.0
7.3
13
16
21
24
27
35
39
44
29
32
39
50
57
91
102
122
150
205
270
290
385
475
515
680
745
865
1020
1100
1300
1500
2000
2200
2800
3000
3200
4000
4200
4500
1
6
0
1
1
4
2
3
1
6
3
5
1
6
0
1
1
4
6
0
8
4
9 L2F
0
8
4
IM B 35
6
6
6
6
Parallel supply cables required (see "Technical information", "Connections, circuits and terminal blocks")
Voltage
1LA8
315 317 355 357 403 405 407 453 455 457
400 V
500 V
Siemens M 11 2003/2004
3/15
Squirrel-cage motors
Order No.
Efficiency
Order No.
supplement for volt- class
age and type of construction, see table
below
rpm
kW
4/4load
%
3/4-
Starting
torque
Stalling
torque
Starting
current
current
torque
Nm
kg m2
kg
Energy-saving motor to CEMEP "High Efficiency" eff1, IP55 degree of protection, temperature class F
3000 rpm, 2-pole, 50 Hz
22
30
37
45
55
75
90
110
132
160
200
1
1
1
1
1
1
1
2955
2960
2960
2965
2975
2975
2978
2982
2982
2982
2982
94.1
93.5
94.1
94.9
95.3
95.2
95.6
95.8
96.0
96.4
96.5
94.5
93.4
94.0
95.1
95.3
95.2
95.7
95.7
95.9
96.4
96.5
0.88
0.88
0.89
0.89
0.90
0.89
0.90
0.91
0.91
0.92
0.93
38.5 1)
53.0 1)
64.0 1)
77.0 1)
93.0
128 1)
150 1)
182 1)
220 1)
260
320
71
97
119
145
177
241
289
352
423
512
641
2.5
2.4
2.5
2.5
2.4
2.5
2.6
2.4
2.6
2.5
2.5
7.2
7.0
7.2
7.3
6.8
7.0
7.6
6.9
7.1
7.1
6.9
3.4
3.3
3.3
3.2
3.0
3.0
3.1
2.8
2.9
2.9
2.8
16
16
16
16
16
13
13
13
13
13
13
0.086
0.15
0.18
0.27
0.47
0.83
1.0
1.4
1.6
2.1
2.5
180
225
255
330
420
530
615
790
915
1055
1245
1
1
1
1
1
1
1
1
1470
1470
1470
1480
1480
1485
1485
1486
1488
1488
1490
1490
92.6
93.2
93.3
94.0
94.5
95.1
95.1
95.4
95.9
96.1
96.3
96.4
93.2
93.5
93.4
94.4
94.7
95.3
95.2
95.5
96.0
96.2
96.4
96.5
0.83
0.84
0.85
0.85
0.85
0.87
0.87
0.86
0.87
0.88
0.88
0.88
34.5 1) 120
40.5 1) 143
55.0 1) 195
67.0 1) 239
81.0 1) 290
96.0
354
130 1)
482
158 1)
578
1
190 )
706
1
225 )
847
1026
275
1282
340
2.5
2.5
2.6
2.7
2.8
2.6
2.5
2.7
2.7
2.7
3.0
3.2
6.4
6.7
6.7
6.8
6.9
7.5
6.8
7.5
7.1
7.3
7.4
7.6
3.0
3.1
3.3
3.0
3.0
3.0
2.9
3.1
2.9
2.9
3.0
3.0
16
16
16
16
16
16
16
16
16
16
16
16
0.12
0.14
0.23
0.40
0.49
0.86
1.40
1.70
2.3
2.9
3.5
4.2
155
180
225
290
330
460
575
675
810
965
1105
1305
180 M
180 L
200 L
225 S
225 M
250 M
280 S
280 M
315 S
315 M
315 L
315 L
1LG6 1834AA . .
1LG6 1864AA . .
1LG6 2074AA . .
1LG6 2204AA . .
1LG6 2234AA . .
1LG6 2534AA . .
1LG6 2804AA . .
1LG6 2834AA . .
1LG6 3104AA . .
1LG6 3134AA . .
1LG6 3164AA . .
1LG6 3174AA . .
6
6
5
5
3/16
Siemens M 11 2003/2004
460 Vd
6
6
8
4
6
Squirrel-cage motors
kW
Order No.
Operating data at rated output
Order No.
Rated Efficiency
Power
supplement for volt- speed h
factor
age and type of conp.f.
at
struction, see table
below
4/43/4load
rpm
%
%
Rated Rated
current torque
at 400 V
Starting
torque
Stalling
torque
Starting
current
current
torque
Nm
KL
kg m2
approx.
kg
180 L
200 L
11
15
18.5
22
30
37
45
55
75
90
110
132
180 L
200 L
225 S
225 M
250 M
280 S
280 M
315 S
315 M
315 L
315 L
315 L
225 M
250 M
280 S
280 M
315 S
315 M
315 L
315 L
315 L
1LG6 1866AA . .
1LG6 2066AA . .
1LG6 2076AA . .
1LG6 2236AA . .
1LG6 2536AA . .
1LG6 2806AA . .
1LG6 2836AA . .
1LG6 3106AA . .
1LG6 3136AA . .
1LG6 3166AA . .
1LG6 3176AA . .
1LG6 3186AA . .
975
978
978
980
985
988
988
990
990
990
990
990
90.9
91.2
91.9
93.2
93.7
94.4
94.6
95.0
95.3
95.6
95.8
95.8
91.7
91.8
92.5
93.7
94.1
94.6
94.8
95.0
95.4
95.7
95.8
95.9
0.81
0.81
0.82
0.83
0.83
0.85
0.85
0.83
0.85
0.85
0.85
0.86
29.5
147
36.0
181
42.0
215
56.0 1) 292
69.0
359
81.0
435
99.0
532
138
723
160
868
196
1061
235
1273
280
1543
2.4
2.4
2.4
2.8
2.9
3.0
3.3
2.8
2.7
2.9
3.1
3.2
5.5
5.6
5.6
6.5
6.8
6.8
7.3
7.3
7.3
7.4
7.8
7.8
2.5
2.4
2.4
2.9
2.5
2.7
2.9
3.0
2.9
2.9
3.1
3.1
16
16
16
16
16
16
16
16
16
16
16
16
0.20
0.29
0.36
0.63
0.93
1.40
1.60
2.5
3.2
4.0
4.7
5.4
175
210
240
325
405
520
570
760
935
1010
1180
1245
725
725
730
730
735
738
738
740
740
740
740
740
88.7
89.3
91.1
91.6
92.8
93.1
93.7
94.3
94.5
94.7
94.8
94.9
89.6
89.8
91.8
92.1
93.3
93.3
94.0
94.4
94.7
95.1
95.1
95.2
0.76
0.80
0.81
0.81
0.82
0.81
0.81
0.82
0.83
0.84
0.84
0.84
23.5
30.5
36.0
43.0
57.0
71.0
86.0
102
138
164
200
240
1.9
2.3
2.3
2.4
2.5
2.3
2.6
2.5
2.5
2.4
2.4
2.5
4.6
5.3
5.6
5.8
6.0
5.7
6.1
6.3
6.7
6.3
6.4
6.7
2.2
2.6
2.6
2.8
2.8
2.3
2.5
2.9
2.9
2.8
2.6
2.9
13
13
13
13
13
13
13
13
13
13
13
13
0.210
0.370
0.550
0.660
1.10
1.40
1.60
2.5
3.1
3.9
4.5
5.3
165
235
295
335
435
510
560
750
840
1005
1100
1270
145
198
242
288
390
479
582
710
968
1161
1420
1704
6
6
5
5
460 V
6
6
8
4
6
3/17
Squirrel-cage motors
Order No.
Operating data at rated output
Order No.
Rated Nominal
Power Rated Rated
supplement for volt- speed efficiency factor
current torque
age and type of conlevel h
p.f.
at 460 V
struction, see table
below
rpm
HP
Starting
torque
Starting
current
Stalling
torque
Torque
class
current
torque
Nm
KL
Moment Weight
of
inertia
Type of
J
constr.
IM B 3
approx.
kg m2
kg
CC 032A
180 M
200 L
225 M
250 M
280 S
280 M
315 S
315 M
315 L
315 L
315 L
1LG6 1832AA . .
1LG6 2062AA . .
1LG6 2072AA . .
1LG6 2232AA . .
1LG6 2282AA . . 1)
1LG6 2532AA . .
1LG6 2582AA . . 1)
1LG6 2802AB . .
1LG6 2832AB . .
1LG6 2882AA . . 1)
1LG6 3102AB . .
1LG6 3132AB . .
1LG6 3162AB . .
1LG6 3172AB . .
1LG6 3182AA . . 1)
3560
3565
3565
3570
3570
3578
3580
3580
3580
3580
3585
3586
3588
3588
3591
93.6
92.4
92.4
94.1
94.1
93.6
94.1
95.0
95.0
95.0
94.5
95.0
95.4
95.4
95.4
0.88
0.88
0.89
0.89
0.90
0.89
0.89
0.89
0.90
0.90
0.91
0.91
0.91
0.93
0.92
34
46
57
67
83
84
112
110
136
164
164
190
215
265
320
1775
1775
1775
1785
1785
1785
1790
1788
1788
1790
1788
1791
1791
1792
1792
1792
92.4
92.4
93.0
93.6
94.1
94.1
94.5
94.5
95.0
95.0
95.0
95.0
95.4
95.4
95.8
95.8
0.82
0.83
0.84
0.84
0.85
0.85
0.86
0.86
0.86
0.86
0.86
0.87
0.87
0.87
0.87
0.87
31
36.5
48
60
70
88
86
116
114
144
172
170
198
225
280
335
60
80
100
120
150
149
199
199
249
299
298
348
397
496
595
2.7
2.7
2.8
2.8
3.3
2.7
2.8
2.8
2.9
3.1
2.6
3.0
3.0
3.2
4.1
7.9
7.8
7.8
8.3
8.7
7.5
8.4
7.9
8.3
8.5
7.5
8.3
8.4
8.6
10.0
3.7
3.7
3.7
3.6
3.7
3.2
3.5
3.4
3.4
3.6
3.1
3.3
3.5
3.4
3.9
16
16
16
16
16
16
16
13
13
16
13
13
13
13
16
0.086
0.151
0.182
0.266
0.319
0.466
0.565
0.832
1.00
1.160
1.39
1.62
2.09
2.46
2.74
180
225
255
330
390
420
470
530
615
660
790
915
1055
1245
1330
100
121
160
200
240
299
298
398
398
497
598
597
696
795
994
1193
2.9
2.8
3.0
3.1
3.3
3.0
2.9
3.0
2.9
3.0
3.1
3.1
3.2
3.7
4.0
4.0
7.1
7.4
7.7
7.5
7.9
7.8
8.2
8.1
7.6
8.2
8.4
7.8
8.4
9.0
9.1
9.3
3.3
3.4
3.7
3.4
3.5
3.3
3.4
3.3
3.2
3.4
3.5
3.2
3.3
3.6
3.7
3.7
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
0.122
0.144
0.234
0.398
0.486
0.660
0.856
0.990
1.39
1.71
1.88
2.31
2.88
3.46
4.22
4.50
155
180
225
290
330
355
460
495
575
675
710
810
965
1105
1305
1345
180 M
180 L
200 L
225 S
225 M
250 M
280 S
280 M
315 S
315 M
315 L
315 L
315 L
1LG6 1834AA . .
1LG6 1864AA . .
1LG6 2074AA . .
1LG6 2204AA . .
1LG6 2234AA . .
1LG6 2284AA . . 1)
1LG6 2534AA . .
1LG6 2584AA . . 1)
1LG6 2804AA . .
1LG6 2834AA . .
1LG6 2884AA . . 1)
1LG6 3104AA . .
1LG6 3134AA . .
1LG6 3164AA . .
1LG6 3174AA . .
1LG6 3184AA . . 1)
6
6
5
5
3/18
Siemens M 11 2003/2004
460 Vd
6
6
8
4
6
Squirrel-cage motors
Order No.
Operating data at rated output
Order No.
Rated Nominal
Power Rated Rated
supplement for volt- speed efficiency factor
current torque
age and type of conlevel h
p.f.
at 460 V
struction, see table
below
rpm
HP
Starting
torque
Starting
current
Stalling
torque
Torque
class
current
torque
Nm
KL
Moment Weight
of
inertia
Type of
J
constr.
IM B 3
approx.
kg m2
kg
CC 032A
180 L
200 L
225 M
250 M
280 S
280 M
315 S
315 M
315 L
315 L
315 L
1LG6 1866AA . .
1LG6 2066AA . .
1LG6 2076AA . .
1LG6 2236AA . .
1LG6 2286AA . . 1)
1LG6 2536AA . .
1LG6 2586AA . . 1)
1LG6 2806AA . .
1LG6 2836AA . .
1LG6 2886AA . . 1)
1LG6 3106AA . .
1LG6 3136AA . .
1LG6 3166AA . .
1LG6 3176AA . .
1LG6 3186AA . .
1178
1180
1180
1184
1184
1186
1186
1190
1190
1190
1191
1191
1192
1192
1192
91.0
91.7
91.7
93.0
93.0
93.0
93.6
94.1
94.5
94.5
94.5
94.5
95.0
95.4
95.4
0.80
0.79
0.80
0.82
0.83
0.82
0.82
0.83
0.83
0.84
0.82
0.84
0.84
0.84
0.84
25.5
32
38.5
49
61
61
73
72
89
118
120
148
176
205
235
121
151
181
240
301
300
361
360
449
599
598
747
897
1046
1195
2.9
2.9
2.9
3.4
3.2
3.4
3.4
3.6
3.9
4.0
3.3
3.0
3.3
3.8
4.0
6.5
6.5
6.4
7.2
7.6
7.4
7.7
7.7
8.3
8.4
8.4
7.9
8.5
8.9
9.4
3.0
2.7
2.7
3.4
3.4
2.9
2.9
3.1
3.3
3.3
3.4
3.1
3.3
3.6
4.0
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
0.203
0.285
0.362
0.629
0.760
0.934
1.07
1.37
1.65
1.94
2.50
3.20
4.02
4.71
5.39
175
210
240
325
355
405
435
520
570
615
760
935
1010
1180
1245
6
6
5
5
460 Vd
6
6
8
4
6
3/19
Squirrel-cage motors
kW
Order No.
Operating data at rated output
Order No.
Rated Efficiency
Power
supplement for volt- speed h
factor
age and type of conp.f.
at
struction, see table
below
4/43/4load
rpm
%
%
Rated Rated
current torque
at 400 V
Starting
torque
Stalling
torque
Starting
current
current
torque
Nm
KL
kg m2
approx.
kg
180 M
200 L
225 M
250 M
280 M
1LG41882AA . .
1LG42082AA . .
1LG42282AA . .
1LG42582AA . .
1LG42882AB . .
2950
2955
2960
2970
2975
92.8
93.6
94.8
94.5
95.5
92.9
93.7
95.0
94.5
95.6
0.86
0.89
0.89
0.88
0.90
54 1)
78 1)
94 1)
130 1)
184 1)
97
145
177
241
353
2.4
2.5
2.6
2.4
2.5
7.1
6.9
7.3
7.1
7.0
3.4
3.2
3.2
3.1
3.0
16
16
16
16
13
0.086
0.18
0.27
0.48
1.00
175
255
335
420
630
1465
1465
1475
1482
1488
91.7
92.5
93.4
94.3
95.2
91.9
92.8
93.9
94.4
94.9
0.80
0.83
0.86
0.85
0.84
59 1)
70 1)
99 1)
136 1)
198 1)
196
241
356
483
706
2.6
2.6
2.5
2.5
2.8
6.3
6.5
6.5
7.0
7.9
2.9
3.0
2.7
3.0
3.3
16
16
16
16
16
0.14
0.23
0.49
0.86
1.71
180
230
330
460
680
970
975
978
982
985
89.6
90.9
92.2
93.3
93.8
90.3
91.3
93.0
93.8
94.3
0.80
0.80
0.83
0.83
0.85
37.5 1)
60 1)
70 1)
84
136 1)
182
294
361
438
727
2.3
2.6
2.5
2.7
3.0
4.9
5.8
5.9
6.3
6.8
2.4
2.6
2.8
2.3
2.8
16
16
16
16
16
0.20
0.36
0.62
0.93
1.65
175
245
325
405
570
720
725
730
730
735
87.8
88.3
90.4
91.9
92.9
88.5
89.2
91.2
92.8
93.7
0.73
0.78
0.79
0.82
0.81
34 1)
39
61 1)
71
106
199
244
392
484
715
2.0
2.4
2.6
2.4
2.4
4.5
5.2
5.6
5.6
5.6
2.4
2.6
2.8
2.6
2.3
13
13
13
13
13
0.21
0.37
0.66
1.06
1.63
165
230
340
430
565
180 L
200 L
225 M
250 M
280 M
1LG41884AA . .
1LG42084AA . .
1LG42284AA . .
1LG42584AA . .
1LG42884AA . .
180 L
200 L
225 M
250 M
280 M
1LG41886AA . .
1LG42086AA . .
1LG42286AA . .
1LG42586AA . .
1LG42886AA . .
180 L
200 L
225 M
250 M
280 M
1LG41888AB . .
1LG42088AB . .
1LG42288AB . .
1LG42588AB . .
1LG42888AB . .
3/20
Siemens M 11 2003/2004
Squirrel-cage motors
Rated
output
1000
rpm
kW
Size
1500
rpm
kW
highest speed.
Order No.
Stalling
torque
Torque
class
torque
1000
rpm
Moment Weight
of
inertia
Type of
J
constr.
IM B 3
1500
rpm
approx.
KL
kg m2
kg
10
10
10
10
10
10
10
10
0.082
0.086
0.151
0.295
0.378
0.447
1.19
1.39
155
175
235
285
340
380
540
580
10
10
10
10
10
10
10
10
0.117
0.144
0.191
0.447
0.486
0.856
1.19
1.71
155
180
220
295
330
430
530
665
Two-speed pole-change for driving fans, IP55 degree of protection, temperature class F
1000/1500 rpm, 6-/4-pole, 50 Hz, design with two windings
5.5
6.5
9.5
12
14.5
18
25
30
16
19
26
34
40
52
70
82
750
rpm
1500
rpm
4.5
5
7.5
9.5
11.5
14.5
19
23
16
18.5
28
35
42
52
70
83
180 M
180 L
200 L
225 S
225 M
250 M
280 S
280 M
1LG4 1831BD . .
1LG4 1861BD . .
1LG4 2071BD . .
1LG4 2201BD . .
1LG4 2231BD . .
1LG4 2531BD . .
1LG4 2801BD . .
1LG4 2831BD . .
960/1460
960/1460
975/1460
980/1465
980/1470
980/1475
982/1478
984/1480
12.0
14.0
20.0
24.5
28.5
34.0
47.0
56.0
31.5
36.5
49.0
63.0
72.0
91.0
124.0
148.0
1.6
1.6
1.9
2.3
2.2
2.0
2.1
2.5
1.7
1.7
1.7
1.7
1.9
2.0
2.2
2.4
4.0
4.0
5.0
5.7
5.6
4.9
5.0
5.5
5.3
5.2
5.1
5.6
5.8
5.9
6.2
6.6
1.8
1.8
2.2
2.1
2.1
2.0
1.9
2.2
2.5
2.4
2.4
2.3
2.3
2.7
2.6
2.8
750
rpm
1500
rpm
750
rpm
1500
rpm
750
rpm
1500
rpm
750
rpm
1500
rpm
2.0
2.1
2.5
2.3
2.2
1.8
1.8
1.8
3.1
3.3
2.9
2.9
3.0
2.6
2.5
2.7
750/1500 rpm, 8-/4-pole, 50 Hz, version with one winding in Dahlander circuit
180 M
180 L
200 L
225 S
225 M
250 M
280 S
280 M
1LG4 1830BB . .
1LG4 1860BB . .
1LG4 2070BB . .
1LG4 2200BB . .
1LG4 2230BB . .
1LG4 2530BB . .
1LG4 2800BB . .
1LG4 2830BB . .
725/1465
725/1470
730/1465
738/1478
738/1475
740/1482
742/1482
742/1485
12.6
14.2
21.5
26.0
30.5
38.0
49.0
58.0
31.0
35.0
52.0
64.0
75.0
94.0
124.0
146.0
1.4
1.6
2.1
2.0
1.9
2.0
1.8
1.9
2.2
2.4
2.7
1.7
2.4
2.5
2.0
2.2
3.6
3.7
4.3
4.4
4.5
4.0
4.0
4.2
6.8
7.2
7.3
6.9
6.9
6.8
6.3
7.2
1
1
6
6
5
5
0
0
IM B 35
6
6
Siemens M 11 2003/2004
3/21
Rated voltage
For motors connected to
converters, the tolerance to
DIN EN 60034-1 is generally applicable, a rated voltage range
Rated
output
Size
Order No.
Operating data at rated output
Order No.
Rated
EffiPower
Rated
Rated
supplement for volt- speed
ciency
factor
current torque
age and type of conp.f.
at 400 V
h
struction, see table
below
rpm
kW
Starting
torque
Starting
current
Torque
class
Nm
Moment
of
inertia
J
Weight
KL
kg m2
Type of
constr.
IM B 3
approx.
kg
315
1LA8 3152PC . .
1LA8 3172PC . .
1LA8 3532PC . .
1LA8 3552PC . .
1LA8 3572PC . .
1LA8 4032PC . .
1LA8 4052PC . .
1LA8 4072PC . .
1LA8 4532PE . .
1LA8 4552PE . .
1LA8 4572PE . .
355
400
450
2979
2979
2980
2980
2982
2985
2985
2985
2986
2986
2986
96.3
96.7
96.6
96.7
97.1
97.1
97.1
97.3
97.2
97.3
97.4
0.90
0.91
0.90
0.91
0.91
0.91
0.91
0.91
0.91
0.92
0.93
415
520
590
660
820
910
1020
670 V C
760 V
840 V
920 V
801
1010
1140
1280
1600
1790
2020
2270
2560
2880
3200
1.8
1.8
1.7
1.7
1.8
1.6
1.6
1.7
0.9
0.9
0.9
7.0
7.0
6.5
6.5
6.5
7.0
7.0
7.0
7.0
7.0
7.0
2.8
2.8
2.5
2.5
2.6
2.8
2.8
2.8
3.0
2.8
2.7
10
10
10
10
10
10
10
10
5
5
5
2.7
3.3
4.8
5.3
6.4
8.6
9.6
11
19
21
23
1300
1500
1900
2000
2200
2800
3000
3200
4000
4200
4400
1486
1488
1488
1488
1488
1492
1492
1492
1492
1492
1492
96.0
96.3
96.3
96.3
96.8
96.8
97.0
97.0
97.0
97.1
97.1
0.88
0.88
0.87
0.87
0.88
0.88
0.88
0.89
0.88
0.88
0.89
425
540
610
690
850
950
1060
690 V C
780 V C
880 V C
970 V
1600
2020
2280
2570
3210
3580
4030
4540
5120
5760
6400
1.9
2.0
2.1
2.1
2.1
1.9
1.9
1.9
1.6
1.6
1.7
6.5
6.8
6.5
6.5
6.5
6.5
6.8
6.8
7.0
7.0
7.0
2.8
2.8
2.6
2.6
2.4
2.7
2.7
2.7
2.6
2.6
2.6
13
13
13
13
13
13
13
13
10
10
10
3.6
4.4
6.1
6.8
8.5
13
14
16
23
26
28
1300
1500
1900
2000
2200
2800
3000
3200
4000
4200
4400
989
989
993
993
992
992
992
993
993
993
95.7
95.9
96.2
96.5
96.5
96.5
96.7
96.8
96.8
97.0
0.86
0.86
0.86
0.86
0.86
0.86
0.86
0.86
0.86
0.86
345
430
540
690
780
860
960
1100
710 V C
790 V C
1930
2410
3040
3850
4330
4810
5390
6060
6830
7690
2.0
2.0
2.2
2.2
2.2
2.3
2.3
2.0
2.0
2.0
6.3
6.3
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
2.5
2.5
2.8
2.8
2.8
2.8
2.8
2.6
2.5
2.5
13
13
13
13
13
13
13
13
13
13
6.0
7.3
13
16
21
24
27
35
39
44
1300
1500
2000
2200
2800
3000
3200
4000
4200
4500
739
739
741
741
742
742
742
744
744
744
94.9
95.2
95.7
96.0
96.1
96.2
96.3
96.4
96.5
96.6
0.82
0.82
0.82
0.82
0.82
0.82
0.82
0.81
0.81
0.81
295
370
460
580
650
730
820
920
1040
1160
2070
2580
3220
4060
4570
5150
5790
6420
7190
8090
2.1
2.1
2.1
2.1
2.0
2.1
2.1
2.0
2.0
2.0
6.0
6.0
6.1
6.1
6.5
6.5
6.5
6.6
6.6
6.6
2.3
2.3
2.4
2.4
2.6
2.6
2.6
2.4
2.4
2.4
13
13
13
13
13
13
13
13
13
13
6.0
7.3
13
16
21
24
27
35
39
44
1300
1500
2000
2200
2800
3000
3200
4000
4200
4500
315
s
s
355
s
s
400
450
1LA8 3154PB . .
1LA8 3174PB . .
1LA8 3534PB . .
1LA8 3554PB . .
1LA8 3574PB . .
1LA8 4034PB . .
1LA8 4054PB . .
1LA8 4074PB . .
1LA8 4534PC . .
1LA8 4554PC . .
1LA8 4574PC . .
315
355
400
450
1LA8 3156PB . .
1LA8 3176PB . .
1LA8 3556PB . .
1LA8 3576PB . .
1LA8 4036PB . .
1LA8 4056PB . .
1LA8 4076PB . .
1LA8 4536PB . .
1LA8 4556PB . .
1LA8 4576PB . .
315
355
400
450
1LA8 3158PB . .
1LA8 3178PB . .
1LA8 3558PB . .
1LA8 3578PB . .
1LA8 4038PB . .
1LA8 4058PB . .
1LA8 4078PB . .
1LA8 4538PB . .
1LA8 4558PB . .
1LA8 4578PB . .
C Also supplied for 400 VD (voltage identifier "9" and order code L1Y).
for 1LA8 motors (for more details see Page 3/13)
4
4 1)
8
8 1)
5
5
7 2)
3/22
Siemens M 11 2003/2004
Rated voltage
For motors connected to
converters, the tolerance to
DIN EN 60034-1 is generally applicable, a rated voltage range
is not specified.
Rated
output
Size
Order No.
Operating data at rated output
Order No.
Rated
EffiPower
Rated
Rated
supplement for volt- speed
ciency
factor
current torque
age and type of conp.f.
at 690 V
h
struction, see table
below
rpm
kW
D40, K45, K46, H15 are not possible. Also, versions for Zone 2,
21 and 22 are not possible.
Starting
torque
Starting
current
Stalling
torque
Torque
class
Moment
of
inertia
J
Weight
KL
kg m2
kg
current
torque
Nm
Type of
constr.
IM B 3
approx.
100 L
112 M
132 S
160 M
160 M
160 L
180 M
200 L
225 M
1LA7 1062PM . .
1LA7 1132PM . .
1LA7 1302PM . .
1LA7 1312PM . .
1LA7 1632PM . .
1LA7 1642PM . .
1LA7 1662PM . .
1LA5 1832PM . .
1LA5 2062PM . .
1LA5 2072PM . .
1LA5 2232PM . .
2890
2905
2925
2930
2940
2940
2940
2940
2945
2945
2960
84.0
86.0
86.5
88.0
89.5
90.0
91.0
91.7
92.3
92.8
93.6
0.85
0.86
0.89
0.89
0.88
0.90
0.91
0.88
0.89
0.89
0.89
3.50
4.55
6.00
8.00
11.6
15.4
18.6
23.0
30.5
37.5
45.0
9.9
13
18
24
36
49
60
71
97
120
145
2.8
2.6
2.0
2.3
2.1
2.2
2.4
2.5
2.4
2.4
2.8
6.8
7.2
5.9
6.9
6.5
6.6
7.0
6.9
7.2
7.7
7.7
3.0
2.9
2.8
3.0
2.9
3.0
3.1
3.2
2.8
2.8
3.4
16
16
16
16
16
16
16
16
16
16
16
0.0035
0.0059
0.015
0.019
0.034
0.043
0.051
0.077
0.14
0.16
0.2
21
27
37
42
63
72
82
113
159
179
209
1420
1420
1440
1455
1455
1460
1460
1460
1460
1465
1470
1470
82.0
82.6
85.0
86.0
87.0
88.5
90.0
90.5
91.2
91.8
92.9
93.4
0.82
0.82
0.83
0.81
0.82
0.84
0.84
0.83
0.84
0.86
0.87
0.87
2.75
3.70
4.75
6.60
8.80
12.4
16.6
20.5
24.0
32.0
38.5
46.5
15
20
27
36
49
72
98
121
144
196
240
292
2.5
2.7
2.7
2.5
2.7
2.2
2.6
2.3
2.3
2.6
2.8
2.8
5.6
5.6
6.0
6.3
6.7
6.2
6.5
7.5
7.5
7.0
7.0
7.7
2.8
3.0
3.0
3.1
3.2
2.7
3.0
3.0
3.0
3.2
3.2
3.3
16
16
16
16
16
16
16
16
16
16
16
16
0.0047
0.0055
0.012
0.018
0.023
0.043
0.055
0.13
0.15
0.24
0.32
0.36
20
23
29
39
46
67
81
113
123
157
206
232
925
940
950
950
950
960
960
970
975
975
978
74.0
78.0
79.0
80.5
83.0
86.0
87.5
89.5
90.2
90.8
91.8
0.75
0.78
0.76
0.76
0.76
0.74
0.74
0.77
0.77
0.77
0.77
2.25
3.05
4.20
5.50
7.30
9.90
14.2
18.2
22.5
26.5
35.5
15
22
30
40
55
75
109
148
181
215
293
2.3
2.2
1.9
2.1
2.3
2.1
2.3
2.0
2.7
2.8
2.8
4.0
4.6
4.2
4.5
5.0
4.6
4.8
5.2
5.5
5.5
5.7
2.3
2.5
2.2
2.4
2.6
2.5
2.6
2.4
2.8
2.9
2.9
16
16
16
16
16
16
16
16
16
16
16
0.0047
0.0091
0.015
0.019
0.025
0.044
0.063
0.15
0.24
0.28
0.36
20
24
34
41
50
70
89
126
161
183
214
100 L
112 M
132 S
132 M
160 M
160 L
180 M
180 L
200 L
225 S
225 M
1LA7 1064PM . .
1LA7 1074PM . .
1LA7 1134PM . .
1LA7 1304PM . .
1LA7 1334PM . .
1LA7 1634PM . .
1LA7 1664PM . .
1LA5 1834PM . .
1LA5 1864PM
1LA5 2074PM . .
1LA5 2204PM . .
1LA5 2234PM . .
100 L
112 M
132 S
132 M
132 M
160 M
160 L
180 L
200 L
225 M
1LA7 1066PM . .
1LA7 1136PM . .
1LA7 1306PM . .
1LA7 1336PM . .
1LA7 1346PM . .
1LA7 1636PM . .
1LA7 1666PM . .
1LA5 1866PM . .
1LA5 2066PM . .
1LA5 2076PM . .
1LA5 2236PM . .
Penultimate
position:
Voltage identifier no rated
voltage range
690 V*
8
8
IM B 14
With standard
flange
2
IM B 14
With special
flange
3
IM B 35
6
6
Other voltages with voltage identifier "9" and Order Code L1Y.
For other types of construction, see "Technical information", "Types
of construction".
1) Not possible for 2- and 4-pole motors from 1LA8 407 upwards and
for 6-pole motors from 1LA8 455
upwards.
3/23
Rated
output
Size
kW
1LA8 motors
These motors are also available
with separately driven fans
(type 1PQ8).
1LG6 motors
It is important to note the following in the case of these motors:
In contrast to the standard version, for windings and motor
protection, options C11, C12,
C13, Y52, A10, and for versions
Order No.
Operating data at rated output
Order No.
Rated
EffiPower
Rated
Rated
supplement for volt- speed
ciency
factor
current torque
age and type of conp.f.
at 690 V
h
struction, see table
below
rpm
%
A
Nm
Starting
torque
Starting
current
Stalling
torque
Torque
class
Moment
of
inertia
J
Weight
KL
kg m2
kg
Type of
constr.
IM B 3
approx.
180 M
200 L
225 M
250 M
280 S
280 M
315 S
315 M
315 L
315
355
400
450
1LG6 1832PM . .
1LG6 2062PM . .
1LG6 2072PM . .
1LG6 2232PM . .
1LG6 2532PM . .
1LG6 2802PM . . V
1LG6 2832PM . . V
1LG6 3102PM . . V
1LG6 3132PM . . V
1LG6 3162PM . . V
1LG6 3172PM . . V
1LA8 3152PM . .
1LA8 3172PM . .
1LA8 3532PM . .
1LA8 3552PM . .
1LA8 3572PM . .
1LA8 4032PM . .
1LA8 4052PM . .
1LA8 4072PM . .
1LA8 4532PM . .
1LA8 4552PM . .
1LA8 4572PM . .
2955
2960
2960
2965
2975
2975
2978
2982
2982
2982
2982
2978
2978
2981
2981
2982
2986
2986
2986
2987
2987
2987
93.7
93.1
93.6
94.4
95.0
95.0
95.3
95.5
95.8
96.2
96.2
96.1
96.5
96.4
96.6
97.0
97.1
97.1
97.2
97.2
97.3
97.4
0.88
0.89
0.89
0.89
0.90
0.89
0.90
0.91
0.91
0.92
0.93
0.90
0.91
0.90
0.91
0.91
0.91
0.92
0.92
0.92
0.92
0.93
22.5
30.5
37
45
54
74
88
106
126
152
188
230
285
335
370
460
520
570
640
730
820
900
71
97
119
145
177
241
289
352
423
512
641
770
962
1105
1249
1553
1743
1951
2175
2478
2798
3101
2.5
2.4
2.5
2.5
2.4
2.5
2.6
2.4
2.6
2.5
2.5
1.8
1.9
1.7
1.7
1.8
1.5
1.6
1.7
0.9
0.9
0.9
7.2
7.0
7.2
7.3
6.8
7.0
7.6
6.9
7.1
7.1
6.9
7.0
7.0
7.0
6.7
7.0
7.0
7.0
7.0
7.0
7.0
7.0
3.4
3.3
3.3
3.2
3.0
3.0
3.1
2.8
2.9
2.9
2.8
3.0
3.0
2.6
2.6
2.6
3.0
2.9
3.0
2.8
2.8
2.8
16
16
16
16
16
13
13
13
13
13
13
10
10
10
10
10
10
10
10
5
5
5
0.086
0.15
0.18
0.27
0.47
0.83
1.00
1.40
1.60
2.1
2.5
2.7
3.3
4.8
5.3
6.4
8.6
9.6
11
19
21
23
180
225
255
330
420
530
615
790
915
1055
1245
1300
1500
1900
2000
2200
2800
3000
3200
4000
4200
4400
1470
1470
1470
1480
1480
1485
1485
1486
1488
1488
1490
1490
1485
1485
1488
1488
1488
1491
1491
1491
1492
1492
1492
92.1
92.7
92.7
93.6
94.1
94.8
94.7
95.1
95.6
95.9
96.1
96.1
95.8
96.0
96.0
96.2
96.5
96.6
96.8
96.9
96.8
97.0
97.1
0.83
0.84
0.85
0.85
0.85
0.87
0.87
0.86
0.87
0.88
0.88
0.88
0.87
0.88
0.87
0.87
0.87
0.88
0.88
0.89
0.88
0.87
0.89
20
23.5
32
39
47
56
76
92
110
130
158
198
235
285
340
385
480
540
600
670
770
870
950
120
143
195
239
290
354
482
578
706
847
1026
1282
1511
1865
2182
2471
3081
3491
3939
4420
5025
5633
6273
2.5
2.5
2.6
2.7
2.8
2.6
2.5
2.7
2.7
2.7
3.0
3.2
1.8
1.8
1.9
2.0
2.1
1.9
1.9
1.9
1.5
1.6
1.7
6.4
6.7
6.7
6.8
6.9
7.5
6.8
7.5
7.1
7.3
7.4
7.6
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
6.9
7.0
7.0
3.0
3.1
3.3
3.0
3.0
3.0
2.9
3.1
2.9
2.9
3.0
3.0
2.8
2.8
2.6
2.6
2.5
2.6
2.7
2.6
2.5
2.6
2.6
16
16
16
16
16
16
16
16
16
16
16
16
13
13
13
13
13
13
13
13
10
10
10
0.12
0.14
0.23
0.40
0.49
0.86
1.40
1.70
2.3
2.9
3.5
4.2
3.6
4.4
6.1
6.8
8.5
13
14
16
23
26
28
155
180
225
290
330
460
575
675
810
965
1105
1305
1300
1500
1900
2000
2200
2800
3000
3200
4000
4200
4400
180 M
180 L
200 L
225 S
225 M
250 M
280 S
280 M
315 S
315 M
315 L
315
355
400
450
1LG6 1834PM . .
1LG6 1864PM . .
1LG6 2074PM . .
1LG6 2204PM . .
1LG6 2234PM . .
1LG6 2534PM . .
1LG6 2804PM . . V
1LG6 2834PM . . V
1LG6 3104PM . . V
1LG6 3134PM . . V
1LG6 3164PM . . V
1LG6 3174PM . . V
1LA8 3154PM . .
1LA8 3174PM . .
1LA8 3534PM . .
1LA8 3554PM . .
1LA8 3574PM . .
1LA8 4034PM . .
1LA8 4054PM . .
1LA8 4074PM . .
1LA8 4534PM . .
1LA8 4554PM . .
1LA8 4574PM . .
Penultimate position:
Voltage identifier
no rated voltage range
690 V*
8
8
8
690 Vd
8
0
8
0
IM V 1
With protective cover
4
4
4
4
IM B 35
6
6
6
6
Other voltages with voltage identifier "9" and Order Code L1Y. For other types of construction, see "Technical information", "Types of construction".
3/24
Siemens M 11 2003/2004
Rated
output
Size
Order No.
Operating data at rated output
Order No.
Rated
EffiPower
Rated
Rated
supplement for volt- speed
ciency
factor
current torque
age and type of conp.f.
at 690 V
h
struction, see table
below
rpm
kW
Starting
torque
Starting
current
Stalling
torque
Torque
class
current
Moment
of
inertia
J
Weight
kg m2
kg
torque
Nm
KL
Type of
constr.
IM B 3
approx.
180 L
200 L
200 L
225 M
250 M
280 S
280 M
315 S
315 M
315 L
315
355
400
450
1LG6 1866PM . .
1LG6 2066PM . .
1LG6 2076PM . .
1LG6 2236PM . .
1LG6 2536PM . .
1LG6 2806PM . . V
1LG6 2836PM . . V
1LG6 3106PM . . V
1LG6 3136PM . . V
1LG6 3166PM . . V
1LG6 3176PM . . V
1LG6 3186PM . . V
1LA8 3156PM . .
1LA8 3176PM . .
1LA8 3556PM . .
1LA8 3576PM . .
1LA8 4036PM . .
1LA8 4056PM . .
1LA8 4076PM . .
1LA8 4536PM . .
1LA8 4556PM . .
1LA8 4576PM . .
975
978
978
980
985
988
988
990
990
990
990
990
990
990
992
992
993
993
993
993
993
993
90.0
90.5
91.4
92.6
93.1
93.9
93.9
94.6
94.9
95.2
95.4
95.3
95.5
95.7
96.2
96.4
96.4
96.5
96.6
96.8
96.8
96.9
0.81
0.81
0.82
0.83
0.83
0.85
0.85
0.83
0.85
0.85
0.85
0.86
0.85
0.86
0.86
0.86
0.85
0.86
0.86
0.84
0.85
0.85
17.2
21
24.5
32.5
40
47
58
80
93
114
136
164
196
240
305
385
445
490
550
630
700
790
147
181
215
292
359
435
532
723
868
1061
1273
1543
1833
2267
2888
3658
4184
4664
5241
5915
6636
7502
2.4
2.4
2.4
2.8
2.9
3.0
3.3
2.8
2.7
2.9
3.1
3.2
2.1
2.2
2.2
2.3
2.1
2.1
2.1
2.0
1.9
2.0
5.5
5.6
5.6
6.5
6.8
6.8
7.3
7.3
7.3
7.4
7.8
7.8
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
2.5
2.4
2.4
2.9
2.5
2.7
2.9
3.0
2.9
2.9
3.1
3.1
2.7
2.7
2.8
2.9
2.8
2.8
2.7
2.7
2.5
2.6
16
16
16
16
16
16
16
16
16
16
16
16
13
13
13
13
13
13
13
13
13
13
0.20
0.29
0.36
0.63
0.93
1.40
1.60
2.5
3.2
4.0
4.7
5.4
6.0
7.3
13
16
21
24
27
35
39
44
175
210
240
325
405
520
570
760
935
1010
1180
1245
1300
1500
2000
2200
2800
3000
3200
4000
4200
4500
725
725
730
730
735
738
738
740
740
740
740
740
740
740
743
743
743
743
743
745
745
745
88.1
88.2
89.9
90.6
91.9
92.6
93.3
93.8
93.9
94.2
94.3
94.4
94.6
94.9
95.5
95.7
96.0
96.1
96.2
96.5
96.6
96.7
0.76
0.80
0.81
0.81
0.82
0.81
0.81
0.82
0.83
0.84
0.84
0.84
0.79
0.80
0.80
0.81
0.80
0.80
0.79
0.78
0.78
0.79
13.8
17.8
21.5
25
33.5
41.5
50
60
81
95
116
140
162
198
250
315
365
410
470
540
610
660
145
198
242
288
390
479
582
710
968
1161
1420
1704
1871
2323
2956
3727
4306
4820
5463
6217
6986
7691
1.9
2.3
2.3
2.4
2.5
2.3
2.6
2.5
2.5
2.4
2.4
2.5
2.2
2.2
2.1
2.1
1.9
1.9
1.9
1.9
2.0
2.0
4.6
5.3
5.6
5.8
6.0
5.7
6.1
6.3
6.7
6.3
6.4
6.7
6.4
6.4
6.8
6.8
6.6
6.9
6.8
6.8
6.8
6.8
2.2
2.6
2.6
2.8
2.8
2.3
2.4
2.9
2.9
2.8
2.6
2.9
2.5
2.5
2.4
2.4
2.6
2.7
2.7
2.5
2.5
2.5
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
0.21
0.37
0.55
0.66
1.10
1.40
1.60
2.5
3.1
3.9
4.5
5.3
6.0
7.3
13
16
21
24
27
35
39
44
165
235
295
335
435
510
560
750
840
1005
1100
1270
1300
1500
2000
2200
2800
3000
3200
4000
4200
4500
180 L
200 L
225 S
225 M
250 M
280 S
280 M
315 S
315 M
315 L
315
355
400
450
1LG6 1868PM . .
1LG6 2078PM . .
1LG6 2208PM . .
1LG6 2238PM . .
1LG6 2538PM . .
1LG6 2808PM . . V
1LG6 2838PM . . V
1LG6 3108PM . . V
1LG6 3138PM . . V
1LG6 3168PM . . V
1LG6 3178PM . . V
1LG6 3188PM . . V
1LA8 3158PM . .
1LA8 3178PM . .
1LA8 3558PM . .
1LA8 3578PM . .
1LA8 4038PM . .
1LA8 4058PM . .
1LA8 4078PM . .
1LA8 4538PM . .
1LA8 4558PM . .
1LA8 4578PM . .
Penultimate position:
Voltage identifier
no rated voltage range
690 V*
8
8
8 1)
690 Vd
7 2)
8
0
IM V 1
With protective cover
4
4
4
IM B 35
6
6
6
Other voltages with voltage identifier "9" and Order Code L1Y.
For other types of construction, see "Technical information", "Types
of construction".
1) Not possible for 6-pole motors
from 1LA8 455 upwards.
3/25
Squirrel-cage motors
1LA9
Cast iron
1LA6
1LG4/1LG6
1LA8
C11
C12
C13
Y52 V
Used acc. to class F
and req. pow- other requirements
er CT ... C or
AH... m above
sea level
A10
PTC thermistor version for alarm on converter-fed operation in Zones 2, 21, 22 2)
A11
Motor protection by means of PTC thermistor with
3 embedded temperature sensors for shutdown 2)
A12
Motor protection by means of PTC thermistor with
6 embedded temp. sensors for alarm and shutdown 2)
A23
Motor temperature sensing with embedded
KTY 84-130 temperature sensors 2)
A25
Motor temperature sensing with 2 embedded
KTY 84-130 temperature sensors 2)
A61
Installation of 6 PT100 G resistance thermometers
A72
56 160 4)
180 225 4) 56 200 3)
100 160
180 315 4)
Service factor 1.1; from size 400 SF 1.05; 1LG6 and 1LA9 SF 1.15
56 160 4)
180 225 4) 56 200 3)
100 160
180 315 4)
10 % increase in power, size 400 upwards 5 %; 1LA9 and 1LG6 15 %
315 450
315 450
Not possible
w. converterfed operation
315 450
56 160 4)
180 225 4) 56 200 3)
100 160
Coolant temperature 55 C, size 400 upwards 50 C
56 160 4)
180 225 4) 56 200
100 160
180 315 4)
180 315 4)
315 450
Not possible
w. converterfed operation
56 160 4)
56 200
100 160
180 315 4)
56 160
180 225
56 200
100 160
180 315
56 200
100 160
180 315
56 160
180 225
56 160 )
180 225 )
56 200
100 160
180 315
Standard version
315 450
180 315
180 315
315 450
180 315
315 450
Paint finish
Standard paintwork in RAL 7030 stone grey
K26
180 315
315 450
M16
56 160
180 225
56 200
100 160
M17
M18
K27
180 315
With order
codeY54
and special
paintwork
RAL ....
315 450
With order
codeY54
and special
paintwork
RAL ....
M19
M20
K28
L42
M21
M22
M23
L43
180 225
56 200
100 160
180 315
315 450
180 315
315 450
56 160
180 225
56 200
100 160
180 315
315 450
56 160
180 225
56 200
100 160
180 315
RAL No.
5017
5018
5019
6019
7000
7004
7011
7016
7022
7033
Name of color
Traffic blue
Turquoise blue
Capri blue
Pastel green
Squirrel grey
Signal grey
Iron grey
Anthracite grey
Umbra grey
Cement grey
Y54 V
And special
paint RAL....
Y53 V
And standard
paint RAL....
K23
K24
3/26
Siemens M 11 2003/2004
RAL No.
1015
1019
2003
2004
3007
5007
5009
5010
5012
5015
Standard version
Name of color
Light ivory
Grey beige
Pastel orange
Pure orange
Wine red
Black blue
Azure blue
Gentian blue
Light blue
Sky blue
Squirrel-cage motors
1LA9
Cast iron
1LA6
1LG4/1LG6
1LA8
63 160
63 160 4)
100 160
180 315 4)
315 450
63 160
63 160 4)
100 160
180 315 4)
315 450
56 160
180 225
56 200 4)
100 160
180 315 4)
M38 ) )
56 160
180 225
56 200 )
100 160
180 315 4)
M35 7)
56 160
180 225
56 200 4)
100 160
180 315 4)
315 450
M39 5)7)
56 160
180 225
56 200 4)
100 160
180 315 4)
315 450
56 132
56 132 11)
56 132
63 112
63 112
63 112
63 112
63 112
63 112
56 160
180 225
56 200
100 160
180 315
56 160
180 225
56 200
100 160
180 315
56 160
180 225
56 200
100 160
180 315
56 160
180 225
56 200
100 160
180 315
56 160
180 225
56 200
100 160
180 315
G56 )
H90 9)
H91 9)
H92 9)
H93 9)
H94 9)
H95 9)
E21
E31
E51
E61
E71
E80
1) Modular installation and additional modules not possible; anti-condensation heating not possible up
to size 200L. The designs for the
zones are not possible for motors
with UL(D31), CSA(D40) and with
special insulation up to 690 V. For
pole-change motors on request.
8) Not possible for pole-change motors. Only one sensor (temperature sensor or PTC thermistor)
connectable.
Siemens M 11 2003/2004
3/27
Squirrel-cage motors
1LA9
Cast iron
1LA6
1LG4/1LG6
1LA8
Modular assembly1)
H57 2)
100 160
180 225
100 160
180 315
H58 2)
100 160
180 225
100 160
180 315
G17 2)
100 160
180 225
100 160
180 315 4)
100 160
180 225
100 160
180 315
100 160
180 225
100 160
180 315
63 160
180 225
180 315 4)
100 160
180 225
180 315
100 160
180 225
180 315
100 160
180 225
180 315 4)
100 160
180 225
180 315
100 160
180 225
180 315
K82
63 160
180 225
180 315
C00
63 160
180 225
180 315
C01
63 160
180 225
180 315
H61 )
2
H97 )
G26 2)
2
H62 )
2
H98 )
H63 2)
2
H64 )
2
H99 )
Additional modules 1) 4)
H70
100 160
180 225
100 160
180 315
315 450
H71
180 225
100 160
180 315
180 225
100 160
180 315
315 450
180 225
100 160
180 315
100 160
180 225
100 160
180 315
100 160
180 225
100 160
180 315
100 160
180 225
180 315
315 450
100 160
180 225
180 315
100 160
180 225
180 315
315 450
315 450
56 132
H78
H72
H74
H79
H73
H75
H80
Y70 V
Converter installation
H15 3)
Mechanical design
K06
200 315 5)
K09
80 160
180 225
80 200
100 160
180 315
K10
80 160
180 225
80 200
100 160
180 315
315 355.
for 400 and
450 standard
version
Standard
version
315 450
K11
180 315
K83
56 160
180 225
56 200
100 160
180 315
315 450
56 160
180 225
56 200
100 160
180 315
315 450
56 160
180 225
56 200
100 160
180 315
315 450
250 315 5)
K84
K85
M46
3/28
Siemens M 11 2003/2004
es. For further details, see Catalogues DA 51.3 and DA 64. Not
possible for motors with special
insulation for 690 V.
4) For 1LG4/1LG6 motors, the Order
Codes G17, G26 and H63 for
frame sizes 225 can also be combined with all rotary pulse encoders listed under "Additional modules".
5) Not possible for designs for
zones; standard version for VIK.
Squirrel-cage motors
1LA9
Cast iron
1LA6
1LG4/1LG6
1LA8
250 315 1)
D02
Coolant temperature 50 C to 40 C
180 315
D03
Coolant temperature 40 C to 40 C
180 315
D04
Coolant temperature 30 C to 40 C
180 315
D01
56 112 2)
56 902)
D30
56 160
180 225
56 200 4)
100 160
180 315 4)
D31
56 160
180 225
56 200
100 160
180 315
D40
315 450
K01
K16
56 160
180 225
56 200
100 160
180 315
With voltage identifier 9 and order code for voltage and frequency
56 160
180 225
56 200
100 160
180 315
For pole-change motors on request
56 160
180 225
56 200
100 160
180 315
315 450
315 450
K17
56 160
180 225
56 200
100 160
180 315
K20
100 160
180 225
100 200
100 160
180 315
315 355
K36
180 250,
K40
Regreasing device
100 160
180 225
L04
56 132
K94
56 132,
160 standard
version
56 160
180 225
56 200
180 250,
standard version from 280
upwards
100 132,
Standard ver-
160 standard sion
version
100 160
180 315
L27
225 315
M44
280 315
L13
External earthing
56 160
180 225
56 200
100 160
Standard version
K30
56 160
56 160
100 160
K31
56 160
180 225
56 200
100 160
180 315
315 450
K32
180 225
56 160
180 225
56 200
100 160
180 315
315 450
132 160
180 225
180 200
132 160
180 225
180 200
132 160
56 200
100 160
180 315
315 450
56 200
100 160
180 315
315 450
Y82 V
and order
codes
K37
K38
K45
K46
56 160 )
180 225 3)
3
180 225 )
Standard for
operation on
frequency
converter
10) Frame sizes 280 to 315 (standard version), but not available
for 2-pole 1LG4/1LG6 motors
with frame size 280.
14) Not required for 1LG6 motors because these motors are already
noise optimized.
15) For 1LA motors in Zone 21, builtin anti-condensation heating is
not possible up to size 200L. For
Zones 2 and 22 on request.
Siemens M 11 2003/2004
3/29
Squirrel-cage motors
1LA9
Cast iron
1LA6
1LG4/1LG6
1LA8
L36
180 315
Standard
version
L99
Wire-lattice pallet
56 160
180
56 180
180 225
56 200
180
56 180
180 225
56 200
100 160
180 315
Standard
version
3/30
Siemens M 11 2003/2004
Squirrel-cage motors
1MAincreased safety
EEx e II type of protection
Selection and ordering data
4/2
Aluminium housing
2-, 4-, 6-pole 50 Hz
4/3
4/4
4/5
4/6
4/6
4/7
4/7
4/7
Special designs
Windings and motor protection
Paint finish
Mechanical design
Certification
Marine version
1MA motors
Increased safety
Frame size
Output range
Temp. class
Temp. class F
63 to 315
0.12 to 165 kW
T1 to T3
Utilization acc. to B
Pressure-resistant 1MJ1/1MJ8 motors are available for the output range from 160 kW to 400 kW
(see "1MJ squirrel-cage motors").
1MA8 motors are not longer available.
For special versions (other frequencies, outputs,
coolant temperatures, installation altitudes, etc.),
certification costs may be incurred.
For motor types that have not yet been acceptance tested by the PTB, changes may arise in
the technical specifications.
Siemens M 11 2003/2004
4/1
Squirrel-cage motors
Rated TemSize
output perature
classes
Order No.
Operating data at rated output
Order No.
Rated EffiPow- Rated Rated
supplement for volt- speed ciency er fac- current torque
age and type of contor p.f. at 380 V
h 1)
struction, see table
to 420 V
below
rpm
kW
Nm
tE time
Torque
For tem- class
perature
classes
T1
T2
T3
KL
Moment Weight
of
inertia
Type of
J
constr.
IM B 3
approx.
kg
kg m2
ATEX
0.18
0.25
0.37
0.55
0.75
1.1
1.3
1.85
2.5
3.3
4.6
5.5
6.5
7.5
9.5
10
13 V
12.5
16 V
T1T3
T1T3
T1T3
T1T3
T1T3
T1T3
T1T3
T1T3
T1T3
T1T3
T1T3
T3
T1, T2
T3
T1, T2
T3
T1, T2
T3
T1, T2
63 M
71 M
80 M
90 S
90 L
100 L
112 M
132 S
160 M
160 M
160 L
2810
2800
2825
2785
2845
2855
2850
2860
2865
2875
2920
2925
2900
2
1MA7 1632BB . . ) 2945
2920
1MA7 1642BB . . 2) 2940
2910
1MA7 1662BB . . 2) 2940
2910
66
68
73
72
73
79
78
81
82
84
83
86
85
87.5
87
88.5
87.5
89
87
0.74
0.85
0.80
0.84
0.85
0.85
0.88
0.88
0.87
0.89
0.90
0.92
0.93
0.90
0.91
0.92
0.92
0.93
0.93
0.55
0.70
0.93
1.4
1.81
2.5
2.9
3.95
5.3
6.7
9.2
10.6
12.5
14.3
18.1
18.6
24.5
23.0
30.0
0.61
0.85
1.3
1.9
2.5
3.7
4.4
6.2
8.3
11
15
18
21
24
31
33
43
41
53
2.3
2.2
2.3
3
2.5
2.8
2.6
2.8
2.6
2.1
1.9
2.2
1.9
2.2
1.7
2.1
1.6
2.3
1.8
4.4
4.4
5.6
5.2
6.2
6.4
6.2
7.2
7.4
6.6
6.8
7.7
6.5
7.6
6.0
7.6
5.8
7.6
5.8
2.3
2.3
3.0
2.6
2.7
3
2.8
2.8
2.8
2.3
2.5
2.7
2.3
3.1
2.4
2.9
2.2
3
2.3
30
19
28
18
13
12
12
9
9
10
15
15
12
29
24
23
16
21
15
27
16
25
13
11
10
11
8
8
9
13
13
7
18
12
16
16
16
16
16
16
16
16
16
13
13
13
13
13
13
13
13
13
13
0.00018
0.00023
0.00035
0.00045
0.00085
0.0011
0.0015
0.002
0.0038
0.0055
0.016
0.021
0.021
0.034
0.034
0.04
0.04
0.052
0.052
4
4
6
7
9
11
13
16
21
27
53
44
44
67
67
72
72
82
82
1375
1330
1310
1355
1390
1395
1420
1415
1420
1415
1435
1445
1460
1455
1465
55
57
60
67
73
73
77
78
80
81
85
86
87
88
89
0.66
0.75
0.77
0.74
0.73
0.75
0.78
0.82
0.82
0.83
0.83
0.82
0.82
0.87
0.84
0.52
0.62
0.80
1.10
1.59
2.05
2.5
3.1
4.5
5.5
7.5
10.4
14.0
19.7
27
0.83
1.3
1.8
2.6
3.8
5.1
6.7
9.1
14
17
24
33
44
66
88
1.9
1.9
1.9
1.9
2.4
2.6
2.2
2.3
2.5
2.6
2.6
2.7
3
2.3
2.4
2.6
2.7
3.1
3.7
4.6
4.8
5.4
5.9
6.4
6.4
7.2
6.6
7.7
6.5
6.9
1.9
1.9
1.9
2.1
2.5
2.6
2.5
2.5
2.7
2.7
2.9
3.2
3.6
2.7
3
35
30
50
35
24
19
16
15
13
12
10
10
10
17
18
30
25
40
29
21
16
14
13
11
10
9
9
9
10
9
13
13
13
13
16
16
16
16
16
16
16
16
16
13
13
0.0003
0.0004
0.0006
0.00083
0.0015
0.0018
0.0028
0.0035
0.0048
0.0058
0.011
0.021
0.027
0.052
0.057
4
4
6
7
9
11
13
16
20
23
29
42
61
67
107
850
920
930
915
910
935
940
945
955
950
960
965
63
68
69
70
72
77
79
79
81
83
85
88
0.72
0.7
0.67
0.75
0.75
0.73
0.76
0.75
0.72
0.76
0.75
0.76
0.81
1.14
1.75
1.8
2.6
3.35
4.7
6.5
9.0
11.4
14.9
21.0
2.8
3.6
5.6
6.8
9.9
13
19
26
35
48
65
96
2.2
2.3
2.4
2.3
2.3
2.4
2.3
1.8
2.3
2.4
2.7
2.8
3
3.6
4
3.9
4.1
4.8
5
4.4
5.1
5.6
6.4
7.7
2.1
2.4
2.4
2.4
2.4
2.5
2.5
2.4
2.8
2.8
3.1
2.2
130
60
30
35
22
26
19
21
16
13
18
15
70
55
27
30
19
26
16
18
13
11
9
8
16
16
16
16
16
16
13
13
13
13
13
13
0.0009
0.0015
0.0025
0.0028
0.0038
0.0063
0.011
0.015
0.019
0.025
0.041
0.055
7
9
13
14
16
20
24
36
41
50
70
105
1MA7 0602BA . .
1MA7 0632BA . .
1MA7 0702BA . .
1MA7 0732BA . .
1MA7 0802BA . .
1MA7 0832BA . .
1MA7 0902BA . .
1MA7 0962BA . .
1MA7 1062BA . .
1MA7 1132BB . .
1MA7 1302BB . .
1MA7 1312BB . . 2)
T1T3
T1T3
T1T3
T3
T1T3
T1T3
T1T3
T1T3
T1T3
T1T3
T1T3
T1T3
T1T3
T1T3
T1T3
63 M
71 M
80 M
90 S
90 L
100 L
112 M
132 S
132 M
160 M
160 L
1MA7 0604BB . .
1MA7 0634BB . .
1MA7 0704BB . .
1MA7 0734BB . .
1MA7 0804BA . .
1MA7 0834BA . .
1MA7 0904BA . .
1MA7 0964BA . .
1MA7 1064BA . .
1MA7 1074BA . .
1MA7 1134BA . .
1MA7 1304BA . .
1MA7 1334BA . .
1MA7 1634BB . .
1MA7 1664BB . .
T1T3
T1T3
T1T3
T1T3
T1T3
T1T3
T1T3
T1T3
T1T3
T1T3
T1T3
T1T3
71 M
80 M
90 S
90 L
100 L
112 M
132 S
132 M
132 M
160 M
160 L
1MA7 0736BA . .
1MA7 0806BA . .
1MA7 0836BA . .
1MA7 0906BA . .
1MA7 0966BA . .
1MA7 1066BA . .
1MA7 1136BB . .
1MA7 1306BB . .
1MA7 1336BB . .
1MA7 1346BB . .
1MA7 1636BB . .
1MA7 1666BB . .
1
6
3
5
4/2
Siemens M 11 2003/2004
IM B 14
With
special
flange
IM B 35
0
0
3
3
6
6
1
1
4
4
2
2
Squirrel-cage motors
Order No.
Operating data at rated output
Order No.
Rated EffiPow- Rated Rated
supplement for volt- speed ciency er fac- current torque
age and type of contor p.f. at 380 V
h 1)
struction, see table
to 420 V
below
rpm
kW
Nm
tE time
Torque
For tem- class
perature
classes
T1
T2
T3
KL
Moment Weight
of
inertia
Type of
J
constr.
IM B 3
approx.
kg
kg m2
ATEX
T1T3
T1T3
T1T3
T3
T1,T2
T3
T1,T2
T3
T1,T2
T3
T1,T2
T3
T1,T2
T3
T1,T2
T3
T1,T2
T3
T1,T2
T3
T1,T2
T3
T1,T2
T3
T1,T2
T3
T1,T2
T3
T1,T2
T3
T1,T2
T3
T1,T2
100 L
112 M
132 S
132 S
132 S
160 M
160 M
160 M
160 M
160 L
160 L
180 M
200 L
225 M
250 M
280 S
280 S
280 M
280 M
315 S
315 S
315 M
315 M
315 L
2865
2875
2920
2925
2900
1MA6 1632BB . . 2) 2945
2920
1MA6 1642BB . . 2) 2940
2910
1MA6 1662BB . . 2) 2940
2910
1MA6 1832BC . .
2955
2935
1MA6 2062BC . .
2950
2960
1MA6 2072BC . .
2965
2950
1MA6 2232BC . .
2970
1MA6 2232AC . .
2970
1MA6 2532BC . .
2975
1MA6 2532AC . .
2975
1MA6 2802BD . .
2983
1MA6 2802AD . .
2980
1MA6 2832BD . .
2982
1MA6 2832AD . .
2978
1MA6 3102BD . .
2985
1MA6 3102AD . .
2985
1MA6 3132BD . .
2985
1MA6 3132AD . .
2985
1MA6 3162BD . .
2984
1MA6 3162AD . .
2984
1MA6 3172BD . .
2985
1MA6 3172AD . .
2986
1MA6 1062BA . .
1MA6 1132BB . .
1MA6 1302BB . .
1MA6 1312BB . . 2)
82
84
83
86
85
87.5
87
88.5
87.5
89
87
92
91.1
91.2
90.6
92
91.4
93.6
93.9
93.5
93.9
94.5
94.3
94.7
94.8
94
94.6
94.8
94.8
94.9
95.2
95.5
95.7
0.87
0.89
0.90
0.92
0.93
0.90
0.91
0.92
0.92
0.93
0.93
0.87
0.88
0.87
0.86
0.87
0.88
0.9
0.89
0.91
0.9
0.9
0.89
0.91
0.9
0.91
0.9
0.91
0.91
0.92
0.91
0.91
0.91
5.3
6.7
9.2
10.6
12.5
14.3
18.1
18.6
24.5
23.0
30.0
29
36.5
49
39
46
60
51
69 3)
64
85
84
115
104
134
120
169
142
198 3)
174
234
214
280
8.3
11
15
18
21
24
31
33
43
41
53
49
62
64
81
77
100
90
122
116
151
150
205
186
244
218
304
256
358
320
432
400
528
2.6
2.1
1.9
2.2
1.9
2.2
1.7
2.1
1.6
2.3
1.8
2
1.6
1.9
1.5
2
1.5
1.8
1.8
1.5
1.5
1.5
1.5
1.5
1.5
1.4
1.5
1.6
1.4
1.4
1.6
1.5
1.8
7.4
6.6
6.8
7.7
6.5
7.6
6.0
7.6
5.8
7.6
5.8
6.9
5.5
6
4.8
6.4
4.9
6.4
7
6.6
6.5
7.1
7.8
7.2
7.5
7.1
7.3
7
7.5
6.8
7.4
7.3
9.3
2.8
2.3
2.5
2.7
2.3
3.1
2.4
2.9
2.2
3.0
2.3
3.3
2.6
2.9
2.3
3
2.3
2.7
2.7
2.7
2.7
2.9
2.9
2.8
2.8
2.8
2.9
2.8
2.7
2.7
2.9
2.5
2.9
9
10
15
15
12
29
24
23
16
21
15
30
24
35
28
35
26
30
16
30
18
30
19
27
15
50
30
40
21
40
17
30
7C
8
9
13
13
7
18
12
14
16
13
13
13
13
13
13
13
13
13
13
10
10
14 10
10
10 10
10
13 10
10
11 10
10
23
7
7
11
7
7
21
7
7
19
7
7
11
7
7
7C 7
7
0.0038
0.0055
0.016
0.021
0.021
0.034
0.034
0.04
0.04
0.052
0.052
0.077
34
43
53
58
58
96
96
105
105
115
115
170
0.14
245
0.16
246
0.24
310
0.45
415
0.79
570
0.92
610
1.3
790
1.5
850
1.8
990
2.3
1100
6
3
5
1) With reference to 75 C.
2) For voltage identifier "9", separate
versions for T1, T2 and T3. For order code A11, only possible for
one power output in each case.
IM B 14
With
special
flange
3
IM B 35
6
6
6
4/3
Squirrel-cage motors
Order No.
Operating data at rated output
Order No.
Rated EffiPow- Rated Rated
supplement for volt- speed ciency er fac- current torque
age and type of contor p.f. at 380 V
h 1)
struction, see table
to 420 V
below
rpm
kW
Nm
tE time
Torque
For tem- class
perature
classes
T1
T2
T3
KL
Moment Weight
of
inertia
Type of
J
constr.
IM B 3
approx.
kg
kg m2
ATEX
2
2.5
3.6
5
6.8
10
13.5
15
17
17.5
20
24
27
30
33
36
40
44
50
58
68
70
80
84
100
100
120
115
135
135
165
T1T3
T1T3
T1T3
T1T3
T1T3
T1T3
T1T3
T3
T1,T2
T3
T1,T2
T3
T1,T2
T3
T1,T2
T3
T1,T2
T3
T1,T2
T3
T1,T2
T3
T1,T2
T3
T1,T2
T3
T1,T2
T3
T1,T2
T3
T1,T2
100 L
100 L
112 M
132 S
132 M
160 M
160 L
180 M
180 M
180 L
180 L
200 L
1MA6 1064BA . .
1MA6 1074BA . .
1MA6 1134BA . .
1MA6 1304BA . .
1MA6 1334BA . .
1MA6 1634BB . .
1MA6 1664BB . .
1MA6 1834BC . .
225 S
225 S
225 M
225 M
250 M
1MA6 2204BC . .
280 S
280 S
280 M
280 M
315 S
315 S
315 M
315 M
315 L
1MA6 2804BC . .
1MA6 1864BC . .
1MA6 2074BC . .
1MA6 2234BC . .
1MA6 2534BC . .
1MA6 2834BC . .
1MA6 3104BD . .
1MA6 3134BD . .
1MA6 3164BD . .
1MA6 3174BD . .
1420
1415
1435
1445
1460
1455
1465
1465
1460
1475
1465
1480
1475
1481
1480
1484
1480
1485
1485
1488
1485
1488
1485
1492
1490
1492
1488
1490
1488
1492
1485
80
81
85
86
87
88
89
90.7
90.0
91.6
90.6
92.5
92.4
93.3
93.1
93.8
93.6
94
93.8
94.6
94.5
94.8
94.8
95.4
95.3
95.8
95.7
95.6
95.5
95.8
95.8
0.82
0.83
0.83
0.82
0.82
0.87
0.84
0.80
0.82
0.80
0.82
0.82
0.84
0.83
0.84
0.84
0.85
0.85
0.86
0.84
0.85
0.85
0.87
0.84
0.85
0.85
0.86
0.86
0.86
0.86
0.87
4.5
5.5
7.5
10.4
14.0
19.7
27
31
35.5
36
41 2)
47.5
53
59
64 2)
70 2)
77 2)
83
94
111
131
130
150 2)
158
188
185
222 2)
214
248
245
305
14
17
24
33
44
66
88
97
111
114
130
155
175
193
213
232
258
283
322
372
437
449
514
538
641
640
770
740
868
868
1061
2.5
2.6
2.6
2.7
3.0
2.3
2.4
1.8
1.6
1.8
1.6
2.2
1.9
1.6
1.4
1.7
1.5
1.7
1.5
1.7
1.5
1.7
1.5
1.7
1.4
1.6
1.3
1.7
1.4
1.7
1.5
6.4
6.4
7.2
6.6
7.7
6.5
6.9
6.1
5.3
6.4
5.6
7.9
7.1
6.7
6.2
6.9
6.2
7.3
6.4
6.3
5.3
7
6
7.7
6.5
7.2
6
7.5
6.4
7.8
6.3
2.7
2.7
2.9
3.2
3.6
2.7
3.0
2.9
2.4
3
2.6
3.1
2.7
2.7
2.5
2.8
2.5
2.5
2.1
2.5
2.1
2.5
2.2
2.8
2.4
2.5
2.1
2.5
2.1
2.8
2.3
13
12
10
10
10
17
18
18
13
16
13
20
19
13
11
12
10
18
15
30
23
26
20
28
24
29
24
28
21
26
17
11
10
9
9
9
10
9
11
11
11
13
12
11
7C
6C
8
7C
5C
7
16
16
16
16
16
13
13
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
7
7
7
7
7
7
7
7
0.0048
0.0058
0.011
0.021
0.027
0.052
0.057
0.13
33
36
45
55
62
100
114
165
0.15
177
0.32
280
0.44
300
0.52
330
0.79
435
1.4
610
1.6
660
2.2
830
2.7
910
3.2
1060
4.2
1200
6
3
5
1) With reference to 75 C.
4/4
Siemens M 11 2003/2004
IM B 14
With
special
flange
IM B 35
0
0
0
6
6
6
1
1
4
4
4
Squirrel-cage motors
Order No.
Operating data at rated output
Order No.
Rated EffiPow- Rated Rated
supplement for volt- speed ciency er fac- current torque
age and type of contor p.f. at 380 V
h 1)
struction, see table
to 420 V
below
rpm
kW
Nm
tE time
Torque
For tem- class
perature
classes
T1
T2
T3
KL
Moment Weight
of
inertia
Type of
J
constr.
IM B 3
approx.
kg
kg m2
ATEX
T1T3
T1T3
T1T3
T1T3
T1T3
T1T3
T1T3
T1T3
T1T3
T1T3
T1T3
T1T3
T1T3
T3
T1,T2
T3
T1,T2
T3
T1,T2
T3
T1,T2
T3
T1,T2
T3
T1,T2
100 L
112 M
132 S
132 M
132 M
160 M
160 L
180 L
200 L
225 M
250 M
280 S
280 M
280 M
315 S
315 S
315 M
315 M
315 L
1MA6 1066BA . .
1MA6 1136BB . .
1MA6 1306BB . .
1MA6 1336BB . .
1MA6 1346BB . .
1MA6 1636BB . .
1MA6 1666BB . .
1MA6 1866BC . .
1MA6 2066BC . .
1MA6 2076BC . .
1MA6 2236BC . .
1MA6 2536BC . .
1MA6 2806BC . .
1MA6 2836BC . .
1MA6 3106BC . .
1MA6 3136BC . .
1MA6 3166BC . .
1MA6 3176BC . .
1MA6 3186BC . .
935
940
945
955
950
960
965
975
980
980
975
985
990
988
987
991
990
991
990
991
990
991
990
991
990
77
79
79
81
83
85
88
89.6
90.5
90.8
92.5
93
93.3
93.5
93.3
94.3
94.2
94.6
94.5
95
94.8
95.2
95
95.2
95
0.73
0.76
0.75
0.72
0.76
0.75
0.76
0.78
0.81
0.82
0.82
0.83
0.85
0.86
0.86
0.84
0.85
0.84
0.84
0.85
0.85
0.84
0.85
0.86
0.86
3.35
4.7
6.5
9.0
11.4
14.9
21.0
28.5
34.5
41
54
66
77
86
96
124
131
146
158
172
185
210
230
220 V
240 V
13
19
26
35
48
65
96
129
161
195
263
320
386
445
484
617
656
732
791
887
945
1060
1160
1210
1300
2.4
2.3
1.8
2.3
2.4
2.7
2.8
1.6
1.7
1.7
1.6
1.6
1.5
1.6
1.5
1.7
1.6
1.7
1.6
1.7
1.6
1.7
1.6
1.6
1.5
4.8
5.0
4.4
5.1
5.6
6.4
7.7
5.4
5.4
5.6
5.6
5.3
6.2
6.5
5.8
6.2
5.9
6.4
5.9
6.5
6.1
6.8
6.2
7
6.5
2.5
2.5
2.4
2.8
2.8
3.1
2.2
2.5
2.6
2.6
2.5
2.4
2.6
2.5
2.3
2.5
2.3
2.5
2.3
2.5
2.3
2.5
2.3
2.5
2.3
26
19
21
16
13
18
15
22
23
22
15
16
13
14
22
18
20
16
17
26
16
18
13
11
9
8
18
19
17
15
16
13
12
16
13
13
13
13
13
13
10
10
10
10
10
10
10
10
14 10
10
8 10
10
9 10
10
6 C 10
10
6 C 10
10
0.0063
0.011
0.015
0.019
0.025
0.041
0.055
0.20
0.29
0.33
0.57
0.89
1.3
1.5
33
40
50
57
66
103
122
177
220
235
305
410
540
580
2.4
770
2.9
830
3.5
970
4.3
1060
4.9
1100
6
3
5
IM B 14
With
special
flange
IM B 35
0
0
0
6
6
6
1
1
4
4
4
1) With reference to 75 C.
Siemens M 11 2003/2004
4/5
Squirrel-cage motors
63 160
Please enquire.
There may be charges for certification.
100 315
Please enquire.
There may be charges for certification.
63 160
100 315 2)
63 160
100 315 2)
225 315
standard design
K26
Standard design
(without order code)
M16
63 160
M17
M18
225 315,
standard design for 100 to 200
(without order code)
100 200
For 225 315
with order code
Y54 and special
paintwork RAL . . .
K27
M19
M20
63 160
100 315
225 315
63 160
100 315
63 160
100 200
Paint finish
K28
L42
M21
M22
M23
L43
Y54 V
And special
paintwork
RAL....
Y53 V
And standard
paintwork
RAL....
K23
K24
4/6
Siemens M 11 2003/2004
RAL No.
1015
1019
2003
2004
3007
5007
5009
5010
5012
5015
Name of color
Light ivory
Grey beige
Pastel orange
Pure orange
Wine red
Black blue
Azure blue
Gentian blue
Light blue
Sky blue
RAL No.
5017
5018
5019
6019
7000
7004
7011
7016
7022
7033
Name of color
Traffic blue
Turquoise blue
Capri blue
Pastel green
Squirrel grey
Signal grey
Iron grey
Anthracite grey
Umbra grey
Cement grey
Squirrel-cage motors
Mechanical design
K09
80 160
100 315
K10
80 160
100 315
K83
63 160
100 315
63 160
100 315
K85
63 160
100 315
K01
63 160
100 315
K84
K16
63 160
100 315
K17
63 160
100 315
K20
100 160
100 315
K40
Regreasing device
100 160
100 250
standard version from 280 upwards
L04
K94
63 132,
160 standard version
63 160
100 132,
160 standard version
100 200
D01
63 90 4)
K30
VIK design )
63 160
100 315
K31
63 160
100 315
63 160
100 315
132 315
K45
225 315
K46
L99
Wire-lattice pallet
63 160
100 180
63 160
100 315
63 160
100 315
63 160
100 315
63 160
100 315
63 160
100 315
63 160
100 315
Y82 V
And order
codes
K37
K38
132 315
225 315
Certification
B02
E11
E21
E31
E51
Siemens M 11 2003/2004
4/7
Squirrel-cage motors
4/8
Siemens M 11 2003/2004
Squirrel-cage motors
1MJexplosion-proof enclosure
EEx de IIC type of protection
Selection and ordering data
5/2
5/3
5/4
5/5
2-pole 50 Hz
4-pole 50 Hz
6-pole 50 Hz
8-pole 50 Hz
5/6
5/6
5/7
5/7
5/7
Special designs
Motor protection
Paint finish
Mechanical design
Certification
Marine version
1MJ motors
Explosion-proof enclosure
Frame size
Output range
Temp. class
Temp. class F
Converter compatible
71 to 450
0.25 to 900 kW
T1 to T4
Utilization acc. to B
Voltage peak times
ts > 0.1 ms at U 500 V
Siemens M 11 2003/2004
5/1
Squirrel-cage motors
Rated
output
Size
kW
Order No.
Operating data at rated output
Order No.
Rated
EffiPower
Rated cur- Rated
supplement for volt- speed
ciency factor
rent at
torque
age and type of conp.f.
400 V
h
struction, see table
below
rpm
%
A
Nm
current
Torque
class
Moment
of
inertia
J
Weight
kg m2
kg
Type of
constr.
IM B 3
approx.
torque
KL
ATEX
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
200
250
315
355
400
450
500
560
630
710
800
900
71 M
80 M
90 L
100 L
112 M
132 S
160 M
160 M
160 L
180 M
200 L
225 M
250 M
280 S
280 M
315 S
315 M
315 M
315 L
355
355
400
450
2750
2790
2840
2835
2850
2860
2885
2895
2925
2930
2940
2940
2940
2940
2940
2945
2955
2965
2975
2975
2980
2980
2980
2980
2980
2980
2978
2978
2984
2982
2983
2986
2986
2986
2985
1MJ6 0702CA . .
1MJ6 0732CA . .
1MJ6 0802CA . .
1MJ6 0832CA . .
1MJ6 0962CA . .
1MJ6 0972CA . .
1MJ6 1062CA . .
1MJ6 1132CA . .
1MJ6 1302CA . .
1MJ6 1312CA . .
1MJ6 1632CA . .
1MJ6 1642CA . .
1MJ6 1662CA . .
1MJ6 1832CA . .
1MJ6 2062CA . .
1MJ6 2072CA . .
1MJ7 2232CB . .
1MJ7 2532CB . .
1MJ7 2802CC . .
1MJ7 2832CC . .
1MJ7 3102CC . .
1MJ7 3132CC . .
1MJ8 3132AB . .
1MJ8 3162AB . .
1MJ8 3532AC . .
1MJ8 3562AC . .
1MJ1 3552AD . .
1MJ1 3572AD . .
1MJ1 4032AE . .
1MJ1 4052AE . .
1MJ1 4072AE . .
1MJ1 4532AE . .
1MJ1 4552AE . .
1MJ1 4572AE . .
1MJ1 4582AE . .
67
71
72
74
78
80
82
84
85
87
88
89
91
92
92.3
92.8
93.9
93.7
94.7
95.1
94.8
95.1
95.7
96.2
96.2
96.6
96.5
96.6
96.7
96.8
97.0
96.9
97.0
97.1
97.2
0.81
0.81
0.86
0.87
0.84
0.86
0.85
0.88
0.89
0.89
0.88
0.91
0.91
0.88
0.89
0.90
0.90
0.90
0.90
0.91
0.90
0.90
0.88
0.89
0.89
0.89
0.91
0.91
0.90
0.91
0.91
0.91
0.91
0.91
0.91
0.98
1.38
1.75
2.45
3.3
4.6
6.2
7.8
10.5
14
20.5
26.5
32.5
39
53
64
77 1)
94
128 1)
150 1)
186 1)
225 1)
280
335
423 2)
530 2)
580
655
745
820
915
600 V
670 V
760 V
850 V
1.3
1.9
2.5
3.7
5.0
7.4
9.9
13
18
24
36
49
60
71
97
120
145
177
241
289
353
423
513
641
801
1009
1138
1282
1440
1601
1792
2014
2270
2557
2879
2.3
2.5
2.4
2.6
2.5
2.8
2.8
2.4
2.0
2.3
2.1
2.2
2.4
2.5
2.4
2.4
2.3
2.1
1.9
2.0
1.8
1.9
2.2
2.3
2.1
2.1
1.0
0.95
0.8
0.8
0.85
0.75
0.8
0.8
0.85
4.3
5.3
6.3
6.3
6.7
7.1
7.7
7.6
5.9
6.9
6.5
6.6
7.0
6.9
6.5
7.7
6.9
6.9
7.0
7.0
7.0
7.0
6.9
6.9
6.7
6.7
6.4
6.1
6.2
5.9
6.2
6.2
6.3
6.3
6.4
2.3
2.6
2.3
2.3
2.5
2.8
3.0
2.8
2.6
2.6
2.6
3.1
3.3
3.2
2.8
2.8
2.7
2.8
2.7
2.7
2.8
2.8
2.5
2.6
2.6
2.6
2.7
2.6
2.8
2.55
2.7
2.7
2.8
2.8
2.7
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
13
13
10
10
10
10
13
13
10
10
7
7
5
5
5
5
5
5
5
0.00035
0.00045
0.00085
0.0011
0.0015
0.0020
0.0038
0.0055
0.015
0.019
0.034
0.043
0.051
0.077
0.14
0.16
0.24
0.45
0.79
0.92
1.3
1.5
2.3
2.8
3.5
4.2
4.3
4.3
6.0
7.0
7.0
11.0
11.0
13.0
13.0
19
20
24
26
32
35
44
57
75
82
123
134
161
175
250
266
335
445
600
640
840
900
1100
1200
1700
2000
2400
2400
2800
3000
3000
4000
4000
4200
4200
1
1
1
1
6
6
6
6
6
6
6
3
3
3
3
3
3
3
5
5
5
5
5
5
5/2
Siemens M 11 2003/2004
0
1
4
0
1
4
0
1
4
IM B 14
With
special
flange
3 3)
IM B 35
6
6
6
6
6
6
6
Squirrel-cage motors
Size
kW
Order No.
Operating data at rated output
Order No.
Rated
EffiPower
Rated cur- Rated
supplement for volt- speed
ciency factor
rent at
torque
age and type of conp.f.
400 V
h
struction, see table
below
rpm
%
A
Nm
current
Torque
class
Moment
of
inertia
J
Weight
kg m2
kg
Type of
constr.
IM B 3
approx.
torque
KL
ATEX
71 M
80 M
90 L
100 L
112 M
132 S
132 M
160 M
160 L
180 M
180 L
200 L
225 S
225 M
250 M
280 S
280 M
315 S
315 M
315 M
315 L
355
355
400
450
1MJ6 0704CB . .
1MJ6 0734CB . .
1MJ6 0804CA . .
1MJ6 0834CA . .
1MJ6 0964CA . .
1MJ6 0974CA . .
1MJ6 1064CA . .
1MJ6 1074CA . .
1MJ6 1134CA . .
1MJ6 1304CA . .
1MJ6 1334CA . .
1MJ6 1634CA . .
1MJ6 1664CA . .
1MJ6 1834CA . .
1MJ6 1864CA . .
1MJ6 2074CA . .
1MJ7 2204CA . .
1MJ7 2234CA . .
1MJ7 2534CA . .
1MJ7 2804CA . .
1MJ7 2834CA . .
1MJ7 3104CA . .
1MJ7 3134CA . .
1MJ8 3134AC . .
1MJ8 3164AB . .
1MJ8 3534AC . .
1MJ8 3544AD . .
1MJ8 3564AC . .
1MJ8 3574AD . .
1MJ1 3534AD . .
1MJ1 3554AD . .
1MJ1 3574AD . .
1MJ1 4034AD . .
1MJ1 4054AD . .
1MJ1 4074AD . .
1MJ1 4534AD . .
1MJ1 4554AD . .
1MJ1 4574AD . .
1325
1375
1395
1395
1410
1420
1420
1415
1435
1450
1450
1455
1455
1460
1460
1465
1475
1475
1480
1485
1485
1488
1488
1485
1485
1485
1490
1485
1490
1491
1491
1491
1492
1492
1492
1493
1493
1493
60
64
71
73
73
77
78
80
83
86
86
87
89
90.5
91.2
91.8
93
93.4
94
94.7
95
94.8
95.5
95.6
95.7
96.2
96.5
96.3
96.6
96.6
96.7
96.8
96.8
96.9
97.0
97.0
97.1
97.2
0.77
0.74
0.79
0.79
0.81
0.8
0.8
0.82
0.82
0.83
0.84
0.85
0.85
0.84
0.85
0.86
0.86
0.87
0.87
0.86
0.86
0.86
0.86
0.86
0.85
0.85
0.86
0.85
0.87
0.86
0.86
0.86
0.87
0.88
0.88
0.89
0.88
0.88
0.78
1.13
1.42
1.88
2.7
3.5
5.1
6.6
8.5
11.1
15
21.5
28.5
35
41
55
67 1)
80 1)
97 1)
132 1)
160 1)
194 1)
232 1)
285
355
400
435 2)
495 2)
540 2)
620
695
785
855 3)
950 3)
1070 2) 3) 4)
1190 2) 3) 4)
1355 2) 3) 4)
880 V
1.8
2.5
3.7
5.1
7.5
10
15
20
27
36
49
72
98
121
144
196
240
292
355
482
579
706
847
1029
1286
1447
1602
1801
2019
2272
2560
2880
3200
3583
4031
4540
5114
5755
1.8
2
2.3
2.5
2.1
2.2
2.2
2.7
2.8
2.4
2.7
2.4
2.8
2.3
2.3
2.6
2.5
2.6
2.6
2.5
2.5
2.5
2.7
2.4
2.5
2.1
1.2
2.1
1.2
1.05
1.05
1.1
1.1
1.1
1.1
0.95
1.0
1.05
3.2
3.6
4.7
5
4.9
5.8
6
6.4
7.2
6.9
7.7
6.6
7.4
7.1
7.1
7.4
7
7
6.7
6.7
6.8
7.0
7.5
6.8
6.9
6.6
6.5
6.6
6.5
6.1
6.0
6.2
6.2
6.2
6.3
6.3
6.6
6.6
1.8
2
2.4
2.6
2.5
2.6
2.6
3
3
3.3
3.3
2.9
3.2
3
3
3.2
3.1
3.2
2.5
2.7
2.8
2.7
3
2.5
2.4
2.3
2.4
2.3
2.4
2.4
2.35
2.4
2.6
2.55
2.6
2.5
2.6
2.5
13
13
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
13
13
13
7
13
7
7
7
7
7
7
7
7
7
7
0.0006
0.0008
0.0015
0.0018
0.0028
0.0035
0.0048
0.0058
0.011
0.018
0.024
0.040
0.052
0.13
0.15
0.24
0.44
0.52
0.79
1.4
1.6
2.2
2.7
3.3
4.0
5.5
6
6.5
7
7.5
9.0
9.0
13
15
15
24.5
24.5
29.0
20
21
24
26
32
35
44
47
58
76
85
128
158
175
189
247
325
355
465
630
680
870
950
1120
1200
1800
1800
2100
2100
2500
2700
2700
3100
3300
3300
4300
4300
4800
1
1
1
1
6
6
6
6
6
6
6
3
3
3
3
3
3
3
5
5
5
5
5
5
0
1
4
0
1
4
0
1
4
IM B 14
With
special
flange
3 5)
IM B 35
6
6
6
6
6
6
6
Siemens M 11 2003/2004
5/3
Squirrel-cage motors
Size
kW
Order No.
Operating data at rated output
Order No.
Rated
EffiPower
Rated cur- Rated
supplement for volt- speed
ciency factor
rent at
torque
age and type of conp.f.
400 V
h
struction, see table
below
rpm
%
A
Nm
current
Torque
class
Moment
of
inertia
J
Weight
kg m2
kg
Type of
constr.
IM B 3
approx.
torque
KL
ATEX
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
200
250
280
315
355
400
450
500
560
630
710
780
71 M
80 M
90 L
100 L
112 M
132 S
132 M
132 M
160 M
160 L
180 L
200 L
225 M
250 M
280 S
280 M
315 S
315 M
315 M
315 M
315 L
355
355
400
450
870
910
900
910
905
930
945
945
945
950
960
960
970
975
975
978
980
982
984
988
988
990
990
990
990
990
993
993
993
994
994
994
995
995
995
995
1MJ6 0736CA . .
1MJ6 0806CA . .
1MJ6 0836CA . .
1MJ6 0966CA . .
1MJ6 0976CA . .
1MJ6 1066CA . .
1MJ6 1136CA . .
1MJ6 1306CA . .
1MJ6 1336CA . .
1MJ6 1346CA . .
1MJ6 1636CA . .
1MJ6 1666CA . .
1MJ6 1866CA . .
1MJ6 2066CA . .
1MJ6 2076CA . .
1MJ7 2236CA . .
1MJ7 2536CA . .
1MJ7 2806CA . .
1MJ7 2836CA . .
1MJ7 3106CA . .
1MJ7 3136CA . .
1MJ8 3136AC . .
1MJ8 3146AC . .
1MJ8 3166AC . .
1MJ8 3536AD . .
1MJ8 3566AD . .
1MJ1 3536AD . .
1MJ1 3556AD . .
1MJ1 3576AD . .
1MJ1 4036AD . .
1MJ1 4056AD . .
1MJ1 4076AD . .
1MJ1 4536AD . .
1MJ1 4556AD . .
1MJ1 4576AD . .
1MJ1 4586AD . .
63
64
64
69
72
75
76
78
79
83
86
87
89
90.2
90.8
92
92.4
93
93.6
93.8
94.2
95.3
95.4
95.5
95.6
95.8
96.3
96.4
96.5
96.5
96.6
96.7
96.9
97.0
97.1
97.2
0.7
0.71
0.74
0.76
0.75
0.73
0.76
0.75
0.76
0.76
0.72
0.74
0.83
0.82
0.83
0.84
0.84
0.86
0.86
0.85
0.85
0.86
0.87
0.87
0.86
0.85
0.84
0.84
0.85
0.84
0.84
0.84
0.85
0.85
0.85
0.85
0.82
1.18
1.67
2.1
2.95
4.0
5.5
7.4
9.6
12.6
17.5
24.5
29.5
36
42.5
56
69
81
99 1)
136
162 1)
195
228
275
350
440
500
560
630
715
800 2)
890 2)
980 2) 3)
1105 2) 3) 4)
1240 2) 3) 4)
790 V
2.7
3.9
5.8
8.0
12
15
22
30
40
55
75
109
148
181
215
293
361
438
534
725
870
1061
1273
1543
1929
2412
2693
3029
3415
3844
4323
4805
5374
6046
6813
7486
2.2
1.9
2
2.2
2.4
2.3
2.2
2
2
2.2
2.1
2.3
2.6
2.6
2.5
2.6
2.6
2.4
2.5
2.4
2.4
2.1
2.1
2.1
1.1
1.1
1.05
1.0
1.0
1.0
1.0
1.05
0.95
0.95
0.95
1.0
3.1
3.3
3.5
3.9
4.3
4.5
4.8
4.8
5
5.4
5.1
5.5
6.3
6.3
5.7
5.7
6
6
6.2
6.2
6.2
6.8
6.6
6.6
6.5
6.5
5.8
5.7
5.6
5.6
5.5
5.7
5.8
5.7
5.7
6.0
2.2
2
2.1
2.3
2.4
2.5
2.5
2.2
2.4
2.5
2.5
2.5
2.4
2.3
2.3
2.2
2.1
2.3
2.4
2.5
2.5
2.3
2.3
2.3
2.2
2.2
2.4
2.35
2.3
2.3
2.25
2.3
2.3
2.3
2.25
2.4
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
10
10
10
7
7
7
7
7
7
7
7
7
7
7
7
0.0009
0.0015
0.0018
0.0028
0.0035
0.0063
0.011
0.015
0.019
0.025
0.041
0.049
0.20
0.29
0.33
0.57
0.89
1.3
1.5
2.4
2.9
4.8
4.8
6.0
8
9
10.5
12.5
12.5
18
21.5
21.5
34.0
34.0
40.0
40.0
16
35
23
32
32
39
52
78
85
92
134
167
190
240
255
330
440
560
600
810
870
1150
1150
1250
1900
2200
2500
2700
2700
3200
3500
3500
4600
4600
4900
4900
1
1
1
1
6
6
6
6
6
6
6
3
3
3
3
3
3
3
5
5
5
5
5
5
5/4
Siemens M 11 2003/2004
0
1
4
0
1
4
0
1
4
IM B 14
With
special
flange
3 5)
IM B 35
6
6
6
6
6
6
6
Squirrel-cage motors
Size
kW
Order No.
Operating data at rated output
Order No.
Rated
EffiPower
Rated cur- Rated
supplement for volt- speed
ciency factor
rent at
torque
age and type of conp.f.
400 V
h
struction, see table
below
rpm
%
A
Nm
current
Torque
class
Moment
of
inertia
J
Weight
kg m2
kg
Type of
constr.
IM B 3
approx.
torque
KL
ATEX
90 L
100 L
112 M
132 S
132 M
160 M
160 M
160 L
180 L
200 L
225 S
225 M
250 M
280 S
280 M
315 S
315 M
315 M
315 M
315 L
355
355
400
450
1MJ6 0968CB . .
1MJ6 0978CB . .
1MJ6 1068CB . .
1MJ6 1078CB . .
1MJ6 1138CB . .
1MJ6 1308CB . .
1MJ6 1338CB . .
1MJ6 1638CB . .
1MJ6 1648CB . .
1MJ6 1668CB . .
1MJ6 1868CB . .
1MJ6 2078CB . .
1MJ7 2208CB . .
1MJ7 2238CB . .
1MJ7 2538CB . .
1MJ7 2808CB . .
1MJ7 2838CB . .
1MJ7 3108CB . .
1MJ7 3138CB . .
1MJ8 3138AB . .
1MJ8 3148AB . .
1MJ8 3168AB . .
1MJ8 3538AD . .
1MJ8 3568AD . .
1MJ1 3558AD . .
1MJ1 3578AD . .
1MJ1 4038AD . .
1MJ1 4058AD . .
1MJ1 4078AD . .
1MJ1 4538AE . .
1MJ1 4558AE . .
1MJ1 4578AE . .
1MJ1 4588AE . .
655
655
665
685
700
695
700
715
710
715
725
725
725
725
730
732
734
738
738
740
740
740
740
740
743
743
744
744
744
745
745
745
745
61
65
65
74
74
74
76
81
83
84
87
87.5
88.6
90.1
91.6
92.7
92.8
93.1
93.6
94.4
94.4
94.4
95.1
95.4
95.9
96.0
96.1
96.2
96.3
96.6
96.7
96.7
96.8
0.76
0.76
0.77
0.74
0.73
0.72
0.72
0.72
0.72
0.72
0.7
0.78
0.8
0.81
0.81
0.82
0.83
0.82
0.82
0.79
0.79
0.8
0.83
0.83
0.83
0.82
0.82
0.82
0.82
0.84
0.83
0.84
0.83
1.16
1.62
2.15
2.9
4.0
6.0
7.9
9.9
13.3
17.9
26
32
37.5
43.5
58
70
84
104
140
175
210
255
292
365
455
515
580
645
735
800 1)
900 1)
1000 1) 2) 3)
1130 1) 2) 3)
5.3
7.9
11
16
21
30
40
54
74
100
145
198
244
290
392
483
585
712
970
1161
1420
1704
2065
2581
3213
3597
4043
4557
5136
5769
6411
7178
8075
1.4
1.5
1.6
1.8
1.8
1.7
1.9
2.1
2.3
2.6
2
2.1
2.1
2.1
2.1
2.2
2.2
2.2
2.3
1.7
1.7
1.8
1.3
1.3
1.1
1.15
1.0
1.0
0.95
0.85
0.85
0.85
0.9
2.8
2.9
3.5
3.9
4.4
4.2
4.4
4.8
5.1
5.8
5
5
5
5
5
5.5
5.5
6
6.2
6.1
6.1
6.1
5.3
5.3
5.4
5.4
5.4
5.3
5.2
5.3
5.2
5.4
5.3
1.7
1.7
1.8
2
2
2.1
2.2
2.3
2.5
2.8
2.2
2.2
2.2
2.2
2.1
2.2
2.2
2.4
2.5
2
2
2
2.2
2.2
2.25
2.3
2.35
2.3
2.25
2.25
2.2
2.25
2.25
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
10
10
10
7
7
7
7
7
7
7
5
5
5
5
0.0025
0.0035
0.0053
0.0070
0.013
0.014
0.019
0.035
0.043
0.062
0.21
0.37
0.58
0.66
1.1
1.4
1.6
2.3
3.0
4.8
4.8
6.0
12
14.7
12.5
12.5
17.5
21.0
21.0
35.5
35.5
42.0
42.0
28
30
40
48
52
78
85
119
134
159
191
263
325
350
465
570
620
780
890
1150
1150
1250
1900
2250
2700
2700
3200
3500
3500
4600
4600
4900
4900
1
1
1
1
6
6
6
6
6
6
6
3
3
3
3
3
3
3
5
5
5
5
5
5
0
1
4
0
1
4
0
1
4
IM B 14
With
special
flange
3 4)
IM B 35
6
6
6
6
6
6
6
Siemens M 11 2003/2004
5/5
Squirrel-cage motors
1MJ7
1MJ8
1MJ1
71 200 V
225 315
315 355
355 450
71 200 s
225 315
315 355 s
355 450 s
71 200 V
225 315
315 355
355 450
71 200 s
225 315
315 355 s
355 450 s
Motor protection
A11
A12
A15
A16
s Anti-condensation
Paint finish
K26
M16
M17
M18
K27
M19
M20
K28
L42
M21
M22
M23
L43
Y54 V
And special
paintwork
RAL....
Y53 V
And standard
paintwork
RAL....
K23
K24
315 355
355 450
315 355
With order code Y54
and special paintwork RAL . . . .
355 450
With order code Y54
and special paintwork RAL . . . .
225 315
315 355
355 450
225 315
315 355
355 450
71 200
225 315
315 355
355 450
71 200
5/6
Standard design
225 315
(without order code)
71 200
225 315
With order code Y54
and special paintwork RAL . . . .
Siemens M 11 2003/2004
RAL No.
1015
1019
2003
2004
3007
5007
5009
5010
5012
5015
Name of color
Light ivory
Grey beige
Pastel orange
Pure orange
Wine red
Black blue
Azure blue
Gentian blue
Light blue
Sky blue
RAL No.
5017
5018
5019
6019
7000
7004
7011
7016
7022
7033
Name of color
Traffic blue
Turquoise blue
Capri blue
Pastel green
Squirrel grey
Signal grey
Iron grey
Anthracite grey
Umbra grey
Cement grey
Squirrel-cage motors
1MJ7
1MJ8
1MJ1
Mechanical design
K09
90 200
225 315
315 355
355 450
K10
90 200
225 315
315 355
355 450
K83
71 200
225 315
315 355
355 450
71 200
225 315
315 355
355 450
K85
71 200
225 315
315 355
355 450
K01
71 200
225 315
315 355
355 450
K84
K16
71 200
225 315
315 355
355 450
K17
71 200
225 315
315 355
355 450
K20
K40
Regreasing device
L27
250 315
315 355
355 450
D01
180 200
225 250
Standard design
71 90 3)
K30
VIK design )
71 200
225 315
315 355
355
K31
71 200
225 315
315 355
355 450
71 200
225 315
315 355
355 450
225 315
315 355
355 450
225 315
315 355
355 450
K45
225 315
315 355 s
355 450 s
K46
71 200 V s
225 315
315 355 s
355 450 s
L99
Wire-lattice pallet
71 160
Y82 V
And order
codes
K37
K38
s6
Certification
B02
71 200
225 315
71 200
225 315
71 200
225 315 8)
71 200
225 315 8)
71 200
225 315 8)
71 200
225 315 8)
E11
E21
E31
E51
1) For 1MJ6/1MJ7 and vertical designs from frame size 180 M upwards available on request, lownoise version (2-pole) not possible.
Design with cover not available.
2) Not possible for size IM V 3, only
for 4-pole to 8-pole motors for size
180 M upwards.
Siemens M 11 2003/2004
5/7
Squirrel-cage motors
5/8
Siemens M 11 2003/2004
Squirrel-cage motors
Sector solutions
Selection and ordering data
6/2
6/2
6/3
6/3
6/4
6/4
6/4
6/7
6/8
6/9
6/10
6/11
6/12
6/13
6/14
6/15
6/15
6/15
6/15
6/15
Marine motors
Overview
Standards and specifications
Mechanical design
Certificates
Smoke extraction motors
Overview
Low-voltage motors for use in smoke and
heat extraction machinery
Technical design
Selection and ordering data
Temperature/time classes F200 and F300
Forced-air cooled squirrel-cage motors
1PP7, 1PP5, 1PP6, 2-pole, 4-pole,
sizes 80 to 315
Forced-air cooled squirrel-cage motors
1PP7, 1PP5, 1PP6, 6-pole,
sizes 80 to 315
Self-cooled squirrel-cage motors
1LA7, 1LA5, 1LG6, 2-pole, 4-pole,
sizes 80 to 315
Self-cooled squirrel-cage motors
1LA7, 1LA5, 1LG6, 6-pole,
sizes 80 to 315
Temperature/time class F400
Forced-air cooled squirrel-cage motors
1PP6, 2-pole, 4-pole,
sizes 100 to 315
Forced-air cooled squirrel-cage motors
1PP6, 6-pole
sizes 100 to 315
Self-cooled squirrel-cage motors
1LA6, 1LG6, 2-pole, 4-pole,
sizes 100 to 315
Self-cooled squirrel-cage motors
1LA6, 1LG6, 6-pole,
sizes 100 to 315
Order codes for special designs
Windings and motor protection
Paint finish
Mechanical design
Notes on safety and commissioning/certification
Additional suffixes
Siemens M 11 2003/2004
6/1
Squirrel-cage motors
Approved motor series type with aluminium (Alu) and cast iron (C iron) housings to the IP55
and IP56 (non-heavy sea) degrees of protection in accordance with Sections 3, 4 and 5. 2)
Motors
Sizes
1LA7/1PP7
1LA5/1PP5
1LA9/1PP9
1LA6
1LG4/1PP4
1LG6/1PP6
1LA8, 1PQ8 3)
Output
range 1)
100 112 132 160 180 200 225 250 280 315 355 400 450 kW
Alu
Alu
Alu
Alu
0.06 18.5
Alu
Alu
Alu
11 45
Alu
Alu
Alu
Alu
Alu
Alu
0.06 53
C iron C iron C iron C iron
0.75 18.5
C iron C iron C iron C iron C iron C iron
11 200
C iron C iron C iron C iron C iron C iron
11 200
C iron C iron C iron C iron 160 1000
56
Alu
63
Alu
71
Alu
80
Alu
90
Alu
Alu
Alu
Alu
Alu
Alu
Alu
Alu
Alu
Alu
BV
Bureau Veritas
(France)
1MA7
1MA6
1MJ6
1MJ7 3)
Alu
Alu
Alu
Alu
C iron C iron C iron C iron C iron C iron C iron C iron C iron C iron
C iron C iron C iron C iron C iron C iron C iron C iron C iron
C iron C iron C iron C iron
0.12 16
1.3 165
0.25 37
18.5 132
GL Germanischer Lloyd
(Germany)
LRS Lloyds Register of
Shipping (Great Britain)
Coolant temperature CT
Limit temperature
for temperature
class F
IEC/EN 60034-1
GL
LRS
BV
DNV
ABS
RINA
CCS
C
40
45
45
45
45
50
45
45
K
105
100
95
100
95
95
95
100
6/2
50
E11/
100
100
E21/
50
E31/
300
E51/
100
100
/E00
50
/E00
100
/E00
Siemens M 11 2003/2004
E11
E21
E31
E51
E61
E71
Squirrel-cage motors
Mechanical versions
In general, all marine motors
have an external earthing terminal. The rating plate features the
relevant marine classification
authority complete with the associated coolant temperature.
In addition, a factory test certificate 2.3 to EN 10 204 is supplied that includes the certificate number of the marine classification authority.
Standard version to IP55 degree of protection, optionally
IP56 (non-heavy sea) can be ordered with order code K52.
Motors can be supplied, depending on the motor series, in
corrosion-resistant aluminium
housing and in rugged cast iron
version. The motors with an aluminium housing in the flange
version have a rugged cast iron
flange.
Increased coolant
temperature
The motors in temperature class
F have a thermal reserve. Derating may be necessary with coolant temperatures higher than
CT 45 C (price supplement).
When ordering, specify Order
No. with -Z and plain text. For
1LA8 motors use Order Code
E80 and plain text when ordering. The permissible output
power can be determined using
the following table.
Reduction
factor
Coolant temperature
CT C
45 50 55 60
1.00 0.96 0.92 0.87
Higher efficiency
The efficiency of marine motors
is similar to that of energy-saving motors. This ensures
energy-saving operation on
board ship.
Certificates
Siemens M 11 2003/2004
6/3
Squirrel-cage motors
Low-voltage motors for use in smoke and heat extraction machinery according to EN 12 101-3
The new low-voltage motors
with squirrel-cage rotors for use
in smoke and heat extraction
machinery in accordance with
EN 12 101-3 are mainly designed for driving smoke extraction fans, so they are also known
as smoke extraction motors.
They are mainly used in buildings that demand smoke monitoring due to their shape and
design. Some typical application examples are tunnels, single and multi-storey shopping
centres, industrial buildings and
warehouses, building complexes and atriums, theatres,
enclosed car parks and stairways.
Technical design
Motor series
The smoke extraction motors
based on basic series 1LA and
1LG
Basic series 1PP.; forced-air
cooled, version without internal fan, located in air flow of
the driven fan
Sub-series 1LA. or 1LG.; selfcooled, version with internal
fan (metal)
The motors are manufactured
with cast iron or aluminium
housings in accordance with
their fire protection classes.
Standards and specifications
Also applicable:
Permanently installed fire fighting equipment EN 12 101-3:
Equipment for controlling
smoke and heat flow, Part 3,
Specification for smoke and
heat extraction units.
6/4
Siemens M 11 2003/2004
Squirrel-cage motors
Bearing plates
All bearing plates are cast iron.
Connection method
Protruding non-metallic
sheathed cable, without terminal block, with cover plate or
funnel cap. Cable length is dependent on the axle height.
Bearing, grease
Special bearing arrangements
matched to the respective temperature class.
In accordance with fire protection classes F200/F300, F400,
and the individual sizes,
grooved ball bearing series of
62 or 63 clearance.
Paint finish
The motors are given a two-part
paint finish as standard (worldwide) in the color shade
RAL 7030.
80
90
100
112
132
160
180
200
225
Size
6
0.60
1.08
1.26
1.98
3.36
6.36
7.267
8.58
8.58
180
200
225
250
280
315
6
8.5
11.0
12.5
17.0
21.5
26.5
Siemens M 11 2003/2004
6/5
Squirrel-cage motors
DE
Type of loading on the shaft
bearing
80
28
6004
90
28
6205
100
28
6206
112
28
6206
132
28
6208
160
28
6209
180
28
6210
200
28
6212
225
28
6213
250
28
6215
280
2
48
6217
6317
315
2
48
6219
6319
No.
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
Radial force
Radial force + axial pull
Axial pull
Radial force
Radial force + axial pull
Axial pull
Radial force
Radial force + axial pull
Axial pull
Radial force
Radial force + axial pull
Axial pull
Radial force
Radial force + axial pull
Axial pull
Radial force
Radial force + axial pull
Axial pull
Radial force
Radial force + axial pull
Axial pull
Radial force
Radial force + axial pull
Axial pull
Radial force
Radial force + axial pull
Axial pull
Radial force
Radial force + axial pull
Axial pull
Radial force
Radial force + axial pull
Axial pull
Radial force
Radial force + axial pull
Axial pull
Shaft horizontally
FR
N
400
150
0
650
250
0
890
400
0
870
400
0
1070
450
0
1440
700
0
1540
770
0
2050
1200
0
2460
1370
0
2770
1400
0
3180
1700
0
3470
1750
0
Load types
S h a ft lo a d ty p e
N o . 1
On request
On request
N o . 2
M 1 -5 2 4 5
A z u g
x /2
F
A x ia l p u ll o n th e s h a ft e n d
Siemens M 11 2003/2004
x /2
N o . 3
6/6
FA pull
N
0
130
215
0
205
343
0
265
490
0
250
480
0
315
580
0
450
825
0
430
815
0
770
1350
0
900
1560
0
840
1500
0
1820
2630
0
2200
3000
M 1 _ 0 5 2 4 4
R a d ia l fo r c e ( s h a ft e n d c e n tr e )
No. of
poles
FR
Radial forces referred to shaft mid-point
FA zug Tensile forces acting axially on the shaft
A z u g
Squirrel-cage motors
kW
Size
Order No.
Order No.
supplements for
voltage and
type of construction, see
table below
Efficiency h
rpm
Power
factor
p.f.
Rated
Rated
current at torque
400 V
A
Nm
Torque
class
KL
Moment
of
inertia
J
kg m2
Weight
Type of
constr.
IM B 3
approx.
kg
EN 12 101-3
Forced-air cooled motors 1PP7, 1PP5 (aluminium housing) and 1PP6 (cast iron housing)
IP55 degree of protection, type of cooling IC 411, temperature/time classes F200 and F300
3000 rpm, 2-pole, 50 Hz
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
200
80 M 1PP7 0802TA . .
1PP7 0832TA . .
90 S 1PP7 0902TA . .
90 L 1PP7 0962TA . .
100 L 1PP7 1062TA . .
112 M 1PP7 1132TA . .
132 S 1PP7 1302TA . .
1PP7 1312TA . .
160 M 1PP7 1632TA . .
1PP7 1642TA . .
160 L 1PP7 1662TA . .
180 M 1PP5 1832TA . .
200 L 1PP5 2062TA . .
1PP5 2072TA . .
225 M 1PP5 2232TA . .
250 M 1PP6 2532TB . .
280 S 1PP6 2802TB . .
280 M 1PP6 2832TB . .
315 S 1PP6 3102TB . .
315 M 1PP6 3132TB . .
315 L 1PP6 3162TB . .
315 L 1PP6 3172TB . .
2830
2845
2860
2880
2890
2905
2925
2930
2940
2940
2940
2940
2945
2945
2960
2975
2975
2975
2985
2984
2984
2984
65.0
75.0
76.0
80.0
78.0
83.0
85.0
88.0
89.5
90.0
91.0
91.7
92.3
92.8
93.6
95.1
95.3
95.6
95.9
96.1
96.3
96.4
0.82
0.80
0.80
0.80
0.83
0.83
0.87
0.89
0.86
0.90
0.91
0.88
0.89
0.89
0.89
0.90
0.91
0.90
0.90
0.91
0.93
0.93
2.1
2.7
3.7
5.1
6.8
8.5
10.7
13.8
21
26.5
32.5
39
53
65
78
94
126
152
186
220
260
325
2.5
3.7
5.0
7.3
9.9
13
18
24
36
49
60
71
97
120
145
177
241
289
352
422
512
640
2.3
2.6
2.4
2.8
2.8
2.6
2.0
2.3
2.1
2.2
2.4
2.5
2.4
2.4
2.8
2.5
2.6
3.0
2.6
2.7
2.8
2.5
5.6
6.1
5.5
6.3
6.8
7.2
5.9
6.9
6.5
6.6
7.0
6.9
7.2
7.7
7.7
7.4
7.5
7.5
7.5
7.4
7.5
7.0
2.4
2.7
2.7
3.1
3.0
2.9
2.8
3.0
2.9
3.0
3.1
3.2
2.8
2.8
3.4
3.3
2.9
3.0
3.2
3.0
3.1
2.8
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
13
13
13
13
13
13
13
0.00085
0.0011
0.0015
0.002
0.0038
0.0055
0.016
0.021
0.034
0.04
0.052
0.077
0.14
0.16
0.2
0.466
0.832
1.00
1.39
1.62
2.09
2.46
9.8
11.5
14.6
17.4
23
31
44
52
71
82
95
119
168
191
226
405
510
595
770
895
1035
1225
61.0
72.0
70.5
74.1
78.5
79.5
80.0
85.0
85.0
88.5
87.0
88.0
90.0
91.8
92.9
93.4
94.9
95.0
94.9
95.3
95.5
95.9
95.7
0.75
0.81
0.74
0.74
0.78
0.78
0.80
0.78
0.78
0.81
0.80
0.79
0.80
0.81
0.87
0.87
0.86
0.87
0.88
0.87
0.87
0.87
0.88
1.96
1.86
3.15
4.0
5.4
7.2
9.2
12
16.5
23
32
40
45
60
66
80
97
132
156
192
230
275
345
3.7
5.1
7.4
10
15
20
27
36
49
72
98
121
144
196
241
293
354
482
579
706
847
1027
1284
2.2
2.3
2.3
2.4
2.5
2.7
2.7
2.5
2.7
2.2
2.6
2.3
2.3
2.6
2.8
2.8
2.9
2.6
2.5
2.6
2.7
2.9
3.2
3.9
4.2
4.6
5.3
5.6
5.6
6.5
6.3
6.7
6.2
6.5
7.5
7.5
7.0
7.0
7.7
7.5
7.3
7.3
6.9
7.0
7.4
7.3
2.2
2.3
2.4
2.6
2.8
3.0
3.0
3.1
3.2
2.7
3.0
3.0
3.0
3.2
3.2
3.3
3.3
2.8
2.8
2.8
2.7
2.9
3.1
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
0.0015
0.0018
0.0028
0.0035
0.0048
0.0058
0.011
0.018
0.024
0.04
0.052
0.13
0.15
0.24
0.32
0.36
0.856
1.39
1.71
2.31
2.88
3.46
4.22
9.6
11
14
17.3
23
26
33
46
52
70
95
116
130
173
218
244
445
555
655
790
945
1085
1285
80 M 1PP7 0804TA . .
1PP7 0834TA . .
90 S 1PP7 0904TA . .
90 L 1PP7 0964TA . .
100 L 1PP7 1064TA . .
1PP7 1074TA . .
112 M 1PP7 1134TA . .
132 S 1PP7 1304TA . .
132 M 1PP7 1334TA . .
160 M 1PP7 1634TA . .
160 L 1PP7 1664TA . .
180 M 1PP5 1834TA . .
180 L 1PP5 1864TA . .
200 L 1PP5 2074TA . .
225 S 1PP5 2204TA . .
225 M 1PP5 2234TA . .
250 M 1PP6 2534TA . .
280 S 1PP6 2804TA . .
280 M 1PP6 2834TA . .
315 S 1PP6 3104TA . .
315 M 1PP6 3134TA . .
315 L 1PP6 3164TA . .
315 L 1PP6 3174TA . .
1395
1395
1415
1420
1420
1415
1440
1450
1455
1460
1460
1460
1460
1465
1470
1470
1485
1486
1485
1488
1488
1488
1488
Forced-air cooled (surface cooled) motors without external fan and fan cover; the motors are located in the air flow of the driven fan and are adequately cooled
during operation under normal conditions.
1
1
1
1
6
6
6
6
6
3
3
3
3
5
5
5
5
6/7
Squirrel-cage motors
kW
Size
Order No.
Order No.
supplements for
voltage and
type of construction, see
table below
Efficiency h
rpm
Power
factor
p.f.
Rated
Rated
current at torque
400 V
A
Nm
Torque
class
KL
Moment
of
inertia
J
kg m2
Weight
Type of
constr.
IM B 3
approx.
kg
EN 12 101-3
Forced-air cooled motors 1PP7, 1PP5 (aluminium housing) and 1PP6 (cast iron housing)
IP55 degree of protection, type of cooling IC 411, temperature/time classes F200 and F300
1000 rpm, 6-pole, 50 Hz
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
80 M 1PP7 0806TA . .
1PP7 0836TA . .
90 S 1PP7 0906TA . .
90 L 1PP7 0966TA . .
100 L 1PP7 1066TA . .
112 M 1PP7 1136TA . .
132 S 1PP7 1306TA . .
132 M 1PP7 1336TA . .
1PP7 1346TA . .
160 M 1PP7 1636TA . .
160 L 1PP7 1666TA . .
180 L 1PP5 1866TA . .
200 L 1PP5 2066TA . .
1PP5 2076TA . .
225 M 1PP5 2236TA . .
250 M 1PP6 2536TA . .
280 S 1PP6 2806TA . .
280 M 1PP6 2836TA . .
315 S 1PP6 3106TA . .
315 M 1PP6 3136TA . .
315 L 1PP6 3166TA . .
315 L 1PP6 3176TA . .
315 L 1PP6 3186TA . .
920
910
915
915
925
940
950
950
950
960
960
970
975
975
978
984
986
986
990
990
990
988
990
62.0
67.0
69.0
72.0
74.0
75.0
79.0
80.5
81.0
83.0
87.5
89.5
90.2
90.8
91.8
92.6
92.8
92.7
93.9
94.3
94.7
94.8
95.0
0.72
0.74
0.76
0.77
0.75
0.70
0.76
0.76
0.75
0.72
0.74
0.77
0.77
0.77
0.77
0.84
0.86
0.87
0.85
0.86
0.87
0.87
0.86
1.2
1.6
2.1
2.9
3.9
6.0
7.2
9.4
14.5
18
24.5
31.5
38.5
45.5
61
69
81
99
136
160
192
230
285
3.9
5.8
7.8
11.5
15
22
30
40
55
75
109
148
181
215
294
359
436
533
723
868
1061
1276
1543
1.9
2.1
2.2
2.3
2.3
2.2
1.9
2.1
2.3
2.1
2.3
2.0
2.7
2.8
2.8
2.7
2.5
2.5
2.7
2.7
2.6
3.0
3.1
3.1
3.4
3.7
3.8
4
4.6
4.2
4.5
5
4.6
4.8
5.2
5.5
5.5
5.7
6.4
6.6
6.5
7.0
7.3
7.4
7.2
7.5
2.1
2.2
2.2
2.3
2.3
2.5
2.2
2.4
2.6
2.5
2.6
2.4
2.8
2.9
2.9
2.4
2.5
2.5
2.9
3.0
3.0
2.8
3.0
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
0.0015
0.0018
0.0028
0.0035
0.0063
0.011
0.015
0.019
0.025
0.041
0.049
0.15
0.24
0.28
0.36
0.934
1.37
1.65
2.50
3.20
4.02
4.71
5.39
9.6
11
14.2
17.4
25
29
44
49
57
78
104
130
173
193
234
390
500
550
740
915
990
1160
1225
Forced-air cooled (surface cooled) motors without external fan and fan cover; the motors are located in the air flow of the driven fan and are adequately cooled
during operation under normal conditions.
1
1
1
1
6
6
6
6
6
3
3
3
3
5
5
5
5
6/8
Siemens M 11 2003/2004
Squirrel-cage motors
kW
Size
Order No.
Order No.
supplements for
voltage and
type of construction, see
table below
Efficiency h
rpm
Power
factor
p.f.
Rated
Rated
current at torque
400 V
A
Nm
Torque
class
KL
Moment
of
inertia
J
kg m2
Weight
Type of
constr.
IM B 3
approx.
kg
EN 12 101-3
Self-cooled motors 1LA7, 1LA5 (aluminium housing) and 1LG6 (cast iron housing)
IP55 degree of protection, type of cooling IC 411, temperature/time classes F200 and F300
3000 rpm, 2-pole, 50 Hz
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
200
80 M 1LA7 0802TA . .
1LA7 0832TA . .
90 S 1LA7 0902TA . .
90 L 1LA7 0962TA . .
100 L 1LA7 1062TA . .
112 M 1LA7 1132TA . .
132 S 1LA7 1302TA . .
1LA7 1312TA . .
160 M 1LA7 1632TA . .
1LA7 1642TA . .
160 L 1LA7 1662TA . .
180 M 1LA5 1832TA . .
200 L 1LA5 2062TA . .
1LA5 2072TA . .
225 M 1LA5 2232TA . .
250 M 1LG6 2532TB . .
280 S 1LG6 2802TB . .
280 M 1LG6 2832TB . .
315 S 1LG6 3102TB . .
315 M 1LG6 3132TB . .
315 L 1LG6 3162TB . .
315 L 1LG6 3172TB . .
2830
2845
2860
2880
2890
2905
2925
2930
2940
2940
2940
2940
2945
2945
2960
2975
2975
2975
2985
2984
2984
2984
65.0
75.0
76.0
80.0
78.0
83.0
85.0
88.0
89.5
90.0
91.0
91.7
92.3
92.8
93.6
94.2
94.8
95.2
95.0
95.3
95.7
95.9
0.82
0.80
0.80
0.80
0.83
0.83
0.87
0.89
0.86
0.90
0.91
0.88
0.89
0.89
0.89
0.90
0.91
0.90
0.90
0.91
0.93
0.93
2.1
2.7
3.7
5.1
6.8
8.5
10.7
13.8
21
26.5
32.5
39
53
65
78
94
126
152
186
220
260
325
2.5
3.7
5.0
7.3
9.9
13
18
24
36
49
60
71
97
120
145
177
241
289
352
422
512
640
2.3
2.6
2.4
2.8
2.8
2.6
2.0
2.3
2.1
2.2
2.4
2.5
2.4
2.4
2.8
2.5
2.6
3.0
2.6
2.7
2.8
2.5
5.6
6.1
5.5
6.3
6.8
7.2
5.9
6.9
6.5
6.6
7.0
6.9
7.2
7.7
7.7
7.4
7.5
7.5
7.5
7.4
7.5
7.0
2.4
2.7
2.7
3.1
3.0
2.9
2.8
3.0
2.9
3.0
3.1
3.2
2.8
2.8
3.4
3.3
2.9
3.0
3.2
3.0
3.1
2.8
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
13
13
13
13
13
13
13
0.00085
0.0011
0.0015
0.002
0.0038
0.0055
0.016
0.021
0.034
0.04
0.052
0.077
0.14
0.16
0.2
0.466
0.832
1.00
1.39
1.62
2.09
2.46
10.2
11.9
15.2
18
24
32
45
53
74
85
98
125
176
199
235
420
530
615
790
915
1055
1245
61.0
72.0
70.5
74.1
78.5
79.5
80.0
85.0
85.0
88.5
87.0
88.0
90.0
91.8
92.9
93.4
94.7
94.6
94.6
95.0
95.3
95.7
95.5
0.75
0.81
0.74
0.74
0.78
0.78
0.80
0.78
0.78
0.81
0.80
0.79
0.80
0.81
0.87
0.87
0.86
0.87
0.88
0.87
0.87
0.87
0.88
1.96
1.86
3.15
4.0
5.4
7.2
9.2
12
16.5
23
32
40
45
60
66
80
97
132
156
192
230
275
345
3.7
5.1
7.4
10
15
20
27
36
49
72
98
121
144
196
241
293
354
482
579
706
847
1027
1284
2.2
2.3
2.3
2.4
2.5
2.7
2.7
2.5
2.7
2.2
2.6
2.3
2.3
2.6
2.8
2.8
2.9
2.6
2.5
2.6
2.7
2.9
3.2
3.9
4.2
4.6
5.3
5.6
5.6
6.5
6.3
6.7
6.2
6.5
7.5
7.5
7.0
7.0
7.7
7.5
7.3
7.3
6.9
7.0
7.4
7.3
2.2
2.3
2.4
2.6
2.8
3.0
3.0
3.1
3.2
2.7
3.0
3.0
3.0
3.2
3.2
3.3
3.3
2.8
2.8
2.8
2.7
2.9
3.1
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
0.0015
0.0018
0.0028
0.0035
0.0048
0.0058
0.011
0.018
0.024
0.04
0.052
0.13
0.15
0.24
0.32
0.36
0.856
1.40
1.70
2.31
2.88
3.46
4.22
10
11.4
14.6
17.9
24
27
34
47
53
73
98
125
139
184
230
256
460
575
675
810
965
1105
1305
80 M 1LA7 0804TA . .
1LA7 0834TA . .
90 S 1LA7 0904TA . .
90 L 1LA7 0964TA . .
100 L 1LA7 1064TA . .
1LA7 1074TA . .
112 M 1LA7 1134TA . .
132 S 1LA7 1304TA . .
132 M 1LA7 1334TA . .
160 M 1LA7 1634TA . .
160 L 1LA7 1664TA . .
180 M 1LA5 1834TA . .
180 L 1LA5 1864TA . .
200 L 1LA5 2074TA . .
225 S 1LA5 2204TA . .
225 M 1LA5 2234TA . .
250 M 1LG6 2534TA . .
280 S 1LG6 2804TA . .
280 M 1LG6 2834TA . .
315 S 1LG6 3104TA . .
315 M 1LG6 3134TA . .
315 L 1LG6 3164TA . .
315 L 1LG6 3174TA . .
1395
1395
1415
1420
1420
1415
1440
1450
1455
1460
1460
1460
1460
1465
1470
1470
1485
1486
1485
1488
1488
1488
1488
1
1
1
1
6
6
6
6
6
3
3
3
3
5
5
5
5
6/9
Squirrel-cage motors
kW
Size
Order No.
Order No.
supplements for
voltage and
type of construction, see
table below
Efficiency h
rpm
Power
factor
p.f.
Rated
Rated
current at torque
400 V
A
Nm
Torque
class
KL
Moment
of
inertia
J
kg m2
Weight
Type of
constr.
IM B 3
approx.
kg
EN 12 101-3
Self-cooled motors 1LA7, 1LA5 (aluminium housing) and 1LG6 (cast iron housing)
IP55 degree of protection, type of cooling IC 411, temperature/time classes F200 and F300
1000 rpm, 6-pole, 50 Hz
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
80 M 1LA7 0806TA . .
1LA7 0836TA . .
90 S 1LA7 0906TA . .
90 L 1LA7 0966TA . .
100 L 1LA7 1066TA . .
112 M 1LA7 1136TA . .
132 S 1LA7 1306TA . .
132 M 1LA7 1336TA . .
1LA7 1346TA . .
160 M 1LA7 1636TA . .
160 L 1LA7 1666TA . .
180 L 1LA5 1866TA . .
200 L 1LA5 2066TA . .
1LA5 2076TA . .
225 M 1LA5 2236TA . .
250 M 1LG6 2536TA . .
280 S 1LG6 2806TA . .
280 M 1LG6 2836TA . .
315 S 1LG6 3106TA . .
315 M 1LG6 3136TA . .
315 L 1LG6 3166TA . .
315 L 1LG6 3176TA . .
315 L 1LG6 3186TA . .
920
910
915
915
925
940
950
950
950
960
960
970
975
975
978
984
986
986
990
990
990
988
990
62.0
67.0
69.0
72.0
74.0
75.0
79.0
80.5
81.0
83.0
87.5
89.5
90.2
90.8
91.8
92.4
92.7
92.6
93.8
94.2
94.6
94.7
94.9
0.72
0.74
0.76
0.77
0.75
0.70
0.76
0.76
0.75
0.72
0.74
0.77
0.77
0.77
0.77
0.84
0.86
0.87
0.85
0.86
0.87
0.87
0.86
1.2
1.6
2.1
2.9
3.9
6.0
7.2
9.4
14.5
18
24.5
31.5
38.5
45.5
61
69
81
99
136
160
192
230
285
3.9
5.8
7.8
11.5
15
22
30
40
55
75
109
148
181
215
294
359
436
533
723
868
1061
1276
1543
1.9
2.1
2.2
2.3
2.3
2.2
1.9
2.1
2.3
2.1
2.3
2.0
2.7
2.8
2.8
2.7
2.5
2.5
2.7
2.7
2.6
3.0
3.1
3.1
3.4
3.7
3.8
4
4.6
4.2
4.5
5
4.6
4.8
5.2
5.5
5.5
5.7
6.4
6.6
6.5
7.0
7.3
7.4
7.2
7.5
2.1
2.2
2.2
2.3
2.3
2.5
2.2
2.4
2.6
2.5
2.6
2.4
2.8
2.9
2.9
2.4
2.5
2.5
2.9
3.0
3.0
2.8
3.0
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
0.0015
0.0018
0.0028
0.0035
0.0063
0.011
0.015
0.019
0.025
0.041
0.049
0.15
0.24
0.28
0.36
0.934
1.40
1.60
2.50
3.20
4.02
4.71
5.39
1
1
1
1
6
6
6
6
6
3
3
3
3
5
5
5
5
6/10
Siemens M 11 2003/2004
9.5
11.4
14.8
18
26
30
45
50
58
81
107
139
184
204
246
405
520
570
760
935
1010
1180
1245
Squirrel-cage motors
Size
kW
Order No.
Order No.
supplements for
voltage and
type of construction, see
table below
Efficiency h
rpm
Power
factor
p.f.
Rated
Rated
current at torque
400 V
A
Nm
Torque
class
KL
Moment
of
inertia
J
kg m2
Weight
Type of
constr.
IM B 3
approx.
kg
EN 12 101-3
2875
2900
2920
2930
2930
2930
2930
2955
2955
2958
2962
2972
2975
2976
2982
2980
2982
2982
79.0
82.0
84.0
85.0
87.0
86.0
87.0
93.1
92.8
93.0
95.0
94.9
94.9
95.2
95.3
95.7
96.0
96.3
0.85
0.85
0.89
0.89
0.85
0.89
0.90
0.88
0.88
0.89
0.89
0.90
0.89
0.90
0.91
0.91
0.92
0.93
6.5
8.7
10.8
14.5
21
27.5
34
39
53
65
77
94
128
152
184
220
265
325
10
13
18
24
36
49
60
71
97
119
145
177
241
289
352
423
512
608
2.5
2.5
1.9
2.0
1.8
2.0
2.0
2.4
2.3
2.4
2.4
2.3
2.4
2.5
2.4
2.5
2.4
2.6
6.2
6.8
5.7
6.5
6.4
6.5
7.0
7.0
6.7
7.1
7.1
6.7
6.8
7.4
6.8
6.9
7.1
7.2
2.8
2.9
2.7
2.8
2.7
2.80
2.70
3.2
3.1
3.2
3.1
2.9
2.9
3.0
2.7
2.8
2.8
2.9
16
16
16
16
16
16
16
16
16
16
16
16
13
13
13
13
13
13
0.0038
0.0055
0.016
0.021
0.034
0.04
0.052
0.086
0.151
0.182
0.266
0.466
0.832
1.00
1.39
1.62
2.09
2.46
31
40
49
54
91
99
109
175
215
245
320
405
510
595
770
895
1035
1225
79.0
79.0
82.0
81.0
84.0
85.0
85.0
91.2
92.1
92.6
92.9
93.6
94.5
94.6
95.1
95.3
95.6
95.8
95.9
0.78
0.80
0.75
0.80
0.75
0.80
0.78
0.84
0.85
0.86
0.86
0.86
0.87
0.87
0.86
0.87
0.88
0.88
0.88
5.5
7.1
9.5
12.8
17.2
24
34
35
40.5
55
67
81
97
132
160
192
225
275
345
15
20
27
36
49
72
98
120
143
195
239
290
354
483
578
706
847
1025
1284
2.2
2.5
2.7
2.5
2.7
2.2
2.4
2.4
2.4
2.4
2.6
2.7
2.5
2.4
2.6
2.7
2.6
2.9
3.1
5.2
5.0
5.7
6.3
6.7
6.2
6.4
6.1
6.4
6.4
6.5
6.6
7.4
6.7
7.3
7.0
7.1
7.2
7.5
2.7
2.6
3.0
3.0
3.1
2.7
2.8
2.8
2.9
3.1
2.8
2.9
2.9
2.8
3.0
2.8
2.8
2.9
2.9
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
0.0048
0.0058
0.011
0.018
0.024
0.04
0.052
0.122
0.144
0.234
0.398
0.486
0.856
1.39
1.71
2.31
2.88
3.46
4.22
31
34
42
51
58
95
108
150
175
215
280
320
445
554
655
790
945
1085
1285
100 L
112 M
132 S
132 M
160 M
160 L
180 M
180 L
200 L
225 S
225 M
250 M
280 S
280 M
315 S
315 M
315 L
315 L
1PP6 1064UA . .
1PP6 1074UA . .
1PP6 1134UA . .
1PP6 1304UA . .
1PP6 1334UA . .
1PP6 1634UA . .
1PP6 1664UA . .
1PP6 1834UA . .
1PP6 1864UA . .
1PP6 2074UA . .
1PP6 2204UA . .
1PP6 2234UA . .
1PP6 2534UA . .
1PP6 2804UA . .
1PP6 2834UA . .
1PP6 3104UA . .
1PP6 3134UA . .
1PP6 3164UA . .
1PP6 3174UA . .
1410
1410
1440
1455
1455
1460
1460
1470
1472
1470
1480
1480
1485
1484
1486
1488
1488
1490
1488
Forced-air cooled (surface cooled) motors without external fan and fan cover; the motors are located in the air flow of the driven fan and are adequately cooled
during operation under normal conditions.
6
6
5
5
6/11
Squirrel-cage motors
Size
kW
Order No.
Order No.
supplements for
voltage and
type of construction, see
table below
Efficiency h
rpm
Power
factor
p.f.
Rated
Rated
current at torque
400 V
A
Nm
Torque
class
KL
Moment
of
inertia
J
kg m2
Weight
Type of
constr.
IM B 3
approx.
kg
EN 12 101-3
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
100 L
112 M
132 S
132 M
132 M
160 M
160 L
180 L
200 L
200 L
225 M
250 M
280 S
280 M
315 S
315 M
315 L
315 L
315 L
1PP6 1066UA . .
1PP6 1136UA . .
1PP6 1306UA . .
1PP6 1336UA . .
1PP6 1346UA . .
1PP6 1636UA . .
1PP6 1666UA . .
1PP6 1866UA . .
1PP6 2066UA . .
1PP6 2076UA . .
1PP6 2236UA . .
1PP6 2536UA . .
1PP6 2806UA . .
1PP6 2836UA . .
1PP6 3106UA . .
1PP6 3136UA . .
1PP6 3166UA . .
1PP6 3176UA . .
1PP6 3186UA . .
925
940
950
950
950
960
960
974
975
975
980
984
986
986
990
988
988
990
988
72.0
75.0
77.0
80.0
81.0
82.0
84.0
88.9
89.8
90.8
92.3
93.0
92.6
93.1
94.0
94.5
94.7
95.1
95.1
0.70
0.74
0.75
0.76
0.76
0.74
0.74
0.82
0.82
0.83
0.84
0.84
0.86
0.86
0.84
0.85
0.85
0.85
0.86
4.5
6.1
7.8
10
14
20
27.5
30
36.5
42.5
56
69
82
99
138
162
198
235
285
15
22
30
40
55
75
109
147
181
215
292
359
436
533
723
870
1063
1273
1546
2.3
2.1
1.6
1.7
2.0
2.0
2.0
2.2
2.2
2.2
2.7
2.8
2.8
3.1
2.7
2.6
2.8
3.0
3.1
4.0
4.4
4.1
4.6
5.0
5.0
5.0
5.2
5.3
5.4
6.3
6.5
6.3
6.8
7.0
7.1
7.2
7.5
7.5
2.3
2.3
1.7
2.1
2.3
2.4
2.5
2.3
2.3
2.3
2.8
2.4
2.5
2.7
2.9
2.8
2.8
3.0
3.0
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
0.0063
0.011
0.015
0.019
0.025
0.041
0.049
0.203
0.285
0.362
0.629
0.934
1.37
1.65
2.50
2.50
2.50
2.50
2.50
31
42
52
62
72
107
129
170
200
230
315
390
500
550
740
915
990
1160
1225
Forced-air cooled (surface cooled) motors without external fan and fan cover; the motors are located in the air flow of the driven fan and are adequately cooled
during operation under normal conditions.
6
6
5
5
6/12
Siemens M 11 2003/2004
Squirrel-cage motors
Size
kW
Order No.
Order No.
supplements for
voltage and
type of construction, see
table below
Efficiency h
rpm
Power
factor
p.f.
Rated
Rated
current at torque
400 V
A
Nm
Torque
class
KL
Moment
of
inertia
J
kg m2
Weight
Type of
constr.
IM B 3
approx.
kg
EN 12 101-3
2875
2900
2920
2930
2930
2930
2930
2955
2955
2958
2962
2972
2975
2976
2982
2980
2982
2982
79.0
82.0
84.0
85.0
87.0
86.0
87.0
92.6
92.2
92.5
94.6
94.3
94.5
94.9
94.7
95.2
95.6
95.9
0.85
0.85
0.89
0.89
0.85
0.89
0.90
0.88
0.88
0.89
0.89
0.90
0.89
0.90
0.91
0.91
0.92
0.93
6.5
8.7
10.8
14.5
21
27.5
34
39
53
65
77
94
128
152
184
220
265
325
10
13
18
24
36
49
60
71
97
119
145
177
241
289
352
423
512
608
2.5
2.5
1.9
2.0
1.8
2.0
2.0
2.4
2.3
2.4
2.4
2.3
2.4
2.5
2.4
2.5
2.4
2.6
6.2
6.8
5.7
6.5
6.4
6.5
7.0
7.0
6.7
7.1
7.1
6.7
6.8
7.4
6.8
6.9
7.1
7.2
2.8
2.9
2.7
2.8
2.7
2.80
2.70
3.2
3.1
3.2
3.1
2.9
2.9
3.0
2.7
2.8
2.8
2.9
16
16
16
16
16
16
16
16
16
16
16
16
13
13
13
13
13
13
0.0038
0.0055
0.016
0.021
0.034
0.04
0.05
0.086
0.151
0.182
0.266
0.466
0.832
1.00
1.39
1.62
2.09
2.46
32
41
51
56
93
102
112
180
225
255
330
420
530
615
790
915
1055
1245
79.0
79.0
82.0
81.0
84.0
85.0
85.0
90.7
91.7
92.2
92.6
93.3
94.2
94.2
94.7
95.0
95.3
95.6
95.7
0.78
0.80
0.75
0.80
0.75
0.80
0.78
0.84
0.85
0.86
0.86
0.86
0.87
0.87
0.86
0.87
0.88
0.88
0.88
5.5
7.1
9.5
12.8
17.2
24
34
35
40.5
55
67
81
97
132
160
192
225
275
345
15
20
27
36
49
72
98
120
143
195
239
290
354
483
578
706
847
1025
1284
2.2
2.5
2.7
2.5
2.7
2.2
2.4
2.4
2.4
2.4
2.6
2.7
2.5
2.4
2.6
2.7
2.6
2.9
3.1
5.2
5.0
5.7
6.3
6.7
6.2
6.4
6.1
6.4
6.4
6.5
6.6
7.4
6.7
7.3
7.0
7.1
7.2
7.5
2.7
2.6
3.0
3.0
3.1
2.7
2.8
2.8
2.9
3.1
2.8
2.9
2.9
2.8
3.0
2.8
2.8
2.9
2.9
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
0.0048
0.0058
0.011
0.018
0.024
0.04
0.052
0.122
0.144
0.234
0.398
0.486
0.856
1.39
1.71
2.31
2.88
3.46
4.22
32
34
43
53
60
97
110
155
180
225
290
330
460
574
675
810
965
1105
1305
100 L
112 M
132 S
132 M
160 M
160 L
180 M
180 L
200 L
225 S
225 M
250 M
280 S
280 M
315 S
315 M
315 L
315 L
1LA6 1064UA . .
1LA6 1074UA . .
1LA6 1134UA . .
1LA6 1304UA . .
1LA6 1334UA . .
1LA6 1634UA . .
1LA6 1664UA . .
1LG6 1834UA . .
1LG6 1864UA . .
1LG6 2074UA . .
1LG6 2204UA . .
1LG6 2234UA . .
1LG6 2534UA . .
1LG6 2804UA . .
1LG6 2834UA . .
1LG6 3104UA . .
1LG6 3134UA . .
1LG6 3164UA . .
1LG6 3174UA . .
1410
1410
1440
1455
1455
1460
1460
1470
1472
1470
1480
1480
1485
1484
1486
1488
1488
1490
1488
6
6
5
5
6/13
Squirrel-cage motors
Size
kW
Order No.
Order No.
supplements for
voltage and
type of construction, see
table below
Efficiency h
rpm
Power
factor
p.f.
Rated
Rated
current at torque
400 V
A
Nm
Torque
class
KL
Moment
of
inertia
J
kg m2
Weight
Type of
constr.
IM B 3
approx.
kg
EN 12 101-3
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
100 L
112 M
132 S
132 M
132 M
160 M
160 L
180 L
200 L
200 L
225 M
250 M
280 S
280 M
315 S
315 M
315 L
315 L
315 L
1LA6 1066UA . .
1LA6 1136UA . .
1LA6 1306UA . .
1LA6 1336UA . .
1LA6 1346UA . .
1LA6 1636UA . .
1LA6 1666UA . .
1LG6 1866UA . .
1LG6 2066UA . .
1LG6 2076UA . .
1LG6 2236UA . .
1LG6 2536UA . .
1LG6 2806UA . .
1LG6 2836UA . .
1LG6 3106UA . .
1LG6 3136UA . .
1LG6 3166UA . .
1LG6 3176UA . .
1LG6 3186UA . .
925
940
950
950
950
960
960
974
975
975
980
984
986
986
990
988
988
990
988
72.0
75.0
77.0
80.0
81.0
82.0
84.0
88.7
89.4
90.5
92.2
92.6
92.3
92.8
93.7
94.2
94.5
94.9
94.9
0.70
0.74
0.75
0.76
0.76
0.74
0.74
0.82
0.82
0.83
0.84
0.84
0.86
0.86
0.84
0.85
0.85
0.85
0.86
4.5
6.1
7.8
10
14
20
27.5
30
36.5
42.5
56
69
82
99
138
162
198
235
285
15
22
30
40
55
75
109
147
181
215
292
359
436
533
723
870
1063
1273
1546
2.3
2.1
1.6
1.7
2.0
2.0
2.0
2.2
2.2
2.2
2.7
2.8
2.8
3.1
2.7
2.6
2.8
3.0
3.1
4.0
4.4
4.1
4.6
5.0
5.0
5.0
5.2
5.3
5.4
6.3
6.5
6.3
6.8
7.0
7.1
7.2
7.5
7.5
2.3
2.3
1.7
2.1
2.3
2.4
2.5
2.3
2.3
2.3
2.8
2.4
2.5
2.7
2.9
2.8
2.8
3.0
3.0
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
0.0063
0.011
0.015
0.019
0.025
0.041
0.049
0.203
0.285
0.362
0.629
0.934
1.37
1.65
2.50
3.20
4.02
4.71
5.39
6
6
5
5
6/14
Siemens M 11 2003/2004
32
43
54
63
74
110
132
175
210
240
325
405
520
570
760
935
1010
1180
1245
Squirrel-cage motors
1PP7
1PP5
1PP6
1LA7
1LA5
1LG6
1LA6
80 160
180 225
100 315
80 160
180 225
180 315
100 160
80 160
180 225
100 315
80 160
180 225
180 315
100 160
80 160
180 225
100 315
80 160
180 225
180 315
100 160
80 160
180 225
180 315
100 160
A23
Paint finish
Special paintwork in RAL 7030 stone grey
M16
80 160
M17
M18
K27
M19
M20
K28
L42
M21
M22
M23
L43
Y54 V
And special
paintwork
RAL . . . .
K23
K24
180 225
100 315
80 160
180 225
100 315
80 160
180 225
180 315
100 160
80 160
180 225
100 315
80 160
180 225
180 315
100 160
80 160
180 225
100 315
80 160
180 225
180 315
100 160
Mechanical design
K40
Regreasing device
100 160
180 225
100 315
100 160
180 225
180 315
100 160
L13
External earthing
80 160
180 225
100 315
80 160
180 225
180 315
100 160
K31
Standard version
80 160
180 225
100 315
80 160
180 225
180 315
100 160
Y82 V
And order
code
K45
80 160
180 225
100 315
80 160
180 225
180 315
100 160
K46
80 160
180 225
100 315
80 160
180 225
180 315
100 160
L99
Wire-lattice pallet
80 160
180
100 180
80 150
180
180
100 160
80 160
180 225
100 315
80 160
180 225
180 315
100 160
Additional suffixes
A60
225
225 315
225
225 315
A61
225
225 315
225
225 315
G50
180 225
180 315
180 225
180 315
K50
180 225
100 315
80 160
180 225
180 315
100 160
L03
Vibration-proof version
80 160
180 225
100 160
80 160
180 225
100 160
L51
80 160
180 225
100 315
80 160
180 225
180 315
100 160
L52
80 160
180 225
100 315
80 160
180 225
180 315
100 160
L68
Full-key balancing
80 160
180 225
100 315
80 160
180 225
180 315
100 160
Siemens M 11 2003/2004
6/15
Squirrel-cage motors
Sector solutions
Notes
6/16
Siemens M 11 2003/2004
Squirrel-cage motors
Dimensions
7/2
7/4
7/6
7/8
7/10
7/12
7/14
7/16
7/18
7/20
Dimension
designation
ISO fit
DIN ISO 286-2
D, DA
to 30
over 30 to 50
over 50
j6
k6
m6
to 250
over 250
j6
h6
h9
F, FA
Dimension
Permitted
deviation
A, B
to 250
over 250 to 500
over 500 to 750
over 750 to 1000
over 1000
0.75
1.0
1.5
2.0
2.5
to 200
over 200 to 500
over 500
0.25
0.5
1.0
to 250
over 250
0.5
1.0
0.5
http://www.siemens.com/automation/CA01
At this address, you will also find links to Tips
and Tricks, and downloads for updating the
functions or content.
Order No. of the CA 01 10/2003 English
E86060-D4001-A110-C1-7600
E, EA
Siemens M 11 2003/2004
7/1
Squirrel-cage motors
Dimensions
IM B 3
L C
L
M 1 -5 1 9 7 c
L L
E D
E E
O
A S
A G
E y e b o lts fr o m
s iz e 1 0 0 L
B C
G C
E C
F ra m e
a n d 2 2
h o u s in
w ith 2
a t N D E
s iz e s
5 S /M
g fe e t
d r ille d
9 0
h a
e a
h o
S /L
v e
c h
le s
E B
A Q
D A
A C
B E '
B E
G A
F A
A F
A D
L M
D B
D C
K
B
B A
E A
C A
K '
H A
A A
B B
A F '
A
B A
A D '
A B
B
B '
B B
C A
C A '
B A '
IM B 5 and IM V1 For flange dimensions, see Page 7/20 (Z = Number of fixing holes)
L L
M 1 -5 1 8 9 d
L C
L
H H
A S
A G
E y e b o lts fr o m
s iz e 1 0 0 L
A D
L M
G A
D B
E C
E E
E D
For motor
Size
Type
1LA7 . . .
1MA7 . . .
56 M 1LA7 050 V
1LA7 053 V
63 M . . . . 060
. . . . 063
71 M . . . . 070
. . . . 073
80 M . . . . 080
. . . . 083
90 S . . . . 090
90 L . . . . 096
100 L . . . . 106
. . . . 107
112 M . . . . 113
132 S . . . . 130
. . . . 131
132 M . . . . 133
. . . . 134
160 M . . . . 163
. . . . 164
160 L . . . . 166
180 M 1LA5 183
180 L 1LA5 186
200 L 1LA5 206
1LA5 207
225 S 1LA5 220
225 M 1LA5 223
No. of
poles
G C
D C
E A
2 to 4
90
25
2 to 6
100
27
2 to 8
112
2 to 8
125
2 to 8
140
2 to 8
4 and 8
2 to 8
2 to 8
2
4 to 8
6
2 to 8
2 and 8
2 to 8
2 and 4
4 to 8
2 and 6
2 to 8
4 and 8
2
4 to 8
101
78
AF
AG
78
74
37
BA
BA BB
71
28
80
28
90
BC
87 34
BE BE C
CA
CA
32
18
36
53
32
40
66
45
83
42
18
(16)
18
(16)
18
(16)
18
(16)
21
101
74
(120)
88
74
(120)
97
75
(114) (120)
105
75
(122) (120)
123 120
124 37
(60)
124 37
(60)
124 37.5
(60)
170 37.5
(60)
170 60
27
100
32
100* 125 33
100 125*
140
47
54
160
78
(95)
111
88
(105)
120
97
(154) (114)
128 105
(162) (122)
163
78
96 30
(52.5)
106 18
(41.5)
118 14
(36)
143 23
(46)
176 39
190
216
46
53
176
194
91
107
136
154
120
140
170 60
250 70
140
140
47
49
176 32
180 39
42
42
21
21
216
53
194
107
154
140
250 70
178
49
218 39
42
21
254
60
226
127
183
165
57
256 52.5
54
27
89 124.5
162.55)
108 183
254
60
226
127
183
165
57
300 52.5
54
27
279
279
318
258
258
305
216
216
252
216
216
252
152
152
260
340 71
340 71
340 96
241
279
305
50
50
58.5
287 38
325 38
355 45
54
54
85
108 139
1796)
27 121 259
27 121 221
42.5 133 239
305
305
252
252
252
252
260
260
340 96
340 96
286* 311 58
286 311* 58
361 36
361 36
85
85
356 103
356 103
Siemens M 11 2003/2004
78
AQ AS
7/2
A Q
F A
D A
A C
A F
B E '
B E
E B
83
83
non-ventilated.
32
32
32
50
94
1344)
56 143
63 125
70 141
89 162.5
118
223.5
Squirrel-cage motors
Dimensions
M 1 -5 1 0 7 e
L L
A S
A G
E y e b o lts fr o m
s iz e 1 0 0 L
B E '
E A
B C
E C
D A
A C
B E
E
G C
H
G A
A Q
E B
F A
A F
A D
L M
L A
E D
K
B
B A
D C
C A
E E
K '
H A
D B
B A
A D '
A B
s iz e s
5 S /M
g fe e t
d r ille d
9 0
h a
e a
h o
B B
S /L
v e
c h
le s
C A
C A '
B
B '
A F '
A
A A
B B
F ra m e
a n d 2 2
h o u s in
w ith 2
a t N D E
B A '
L C
L L
M 1 -5 1 9 8 c
A S
A G
E y e b o lts fr o m
s iz e 1 0 0 L
A D
L M
A Q
F A
E A
D A
A C
A F
B E '
B E
E B
E
G A
E C
G C
D C
E D
D B
HA HH
56
63
71
80
90
10
100
69.5
E E
LC
169
200
LL
5.8
9
10
202.5
232
10
240
278
12
69.5
7
(92.5)
63.5
7
(86.5)
63.5
9.5
(86)
79
10
(101.5)
102
12
16
372
112
132
12
15
102
128
12
12
16
16
393
461
452.53) 551.5
120
140
132
15
128
12
16
160
18
160.5
15
19
160
18
160.5
15
19
180
180
200
18
18
24
159
159
178
15
15
19
19
19
25
225
225
24
24
184.5
184.5
19
19
25
25
20
14
10.2 9
M3
20
14
3 10.2
11
M4
23
16
3.5
12.5 11
M4
23
16
3.5
4 12.5
14
M5
30
22
16
14
M5
30
22
5 16
19
M6
40
32
21.5 19
M6
40
32
6 21.5
24
M8
50
40
27
19
M6
40
32
6 21.5
28
M10
60
50
31
24
M8
50
40
8 27
444.5
5053)
2x M32 x 1.52) 28
2x M32 x 1.52) 38
M10
M12
60
80
50
70
5
5
8
10
31
41
24
38
M8
50
M12 80
40
70
5
5
8 27
10 41
452.53) 551.5
140
490.55) 589.55)
588
721
165
5053)
5435)
640.5
2x M32 x 1.52) 38
M12
80
70
10
41
38
M12 80
70
10 41
2x M32 x 1.52) 42
M16 110
90 10
12
45
42
M16 110
90 10
12 45
588
6286)
712
712
768.5
721
7616)
841
841
897
165
640.5
680.56)
793.5
793.5
850
2x M32 x 1.52) 42
M16 110
90 10
12
45
42
M16 110
90 10
12 45
2 x M40 x 1.5
2 x M40 x 1.5
2 x M50 x 1.5
48
48
55
5
5
5
14
14
16
51.5 48
51.5 48
59 55
5
5
5
14 51.5
14 51.5
16 59
806
776
806
933.5
903.5
933.5
192
192
887.5
857.5
887.5
2 x M50 x 1.5
2 x M50 x 1.5
60
55
60
7.5 18
5 16
7.5 18
64
59
64
5
5
16 59
16 59
3) In a low-noise version, the dimension L is 8 mm greater and the dimension LM is 11.5 mm greater.
1x M16 x 1.5
1x M25 x 1.5
74
231.5
1x M16 x 1.5
(120)
1x M25 x 1.5
74
268
1x M16 x 1.5
(120)
1x M25 x 1.5
75
299.5
1x M16 x 1.5
(120) 334.54) 1x M25 x 1.5
75
382.5
1x M16 x 1.5
(120)
1x M25 x 1.5
120
423.5
2x M32 x 1.52)
M3
438
132
132
192
13.5 273.5
324
308.54) 364
14
331
389
74
LM
55
55
Siemens M 11 2003/2004
7/3
Squirrel-cage motors
Dimensions
IM B 3
L C
L
M 1 -5 1 9 7 c
L L
E D
E E
O
A S
A G
E y e b o lts fr o m
s iz e 1 0 0 L
B C
G C
E C
F ra m e
a n d 2 2
h o u s in
w ith 2
a t N D E
s iz e s
5 S /M
g fe e t
d r ille d
9 0
h a
e a
h o
S /L
v e
c h
le s
E B
A Q
D A
A C
B E '
B E
G A
F A
A F
A D
L M
D B
D C
K
B
B A
E A
C A
K '
H A
A A
B B
A F '
A
B A
A D '
A B
B
B '
B B
C A
C A '
B A '
IM B 5 and IM V1 For flange dimensions, see Page 7/20 (Z = Number of fixing holes)
M 1 -5 2 3 8 a
L C
L
H H
E E
L L
A S
A G
E y e b o lts fr o m
s iz e 1 0 0 L
A D
L M
G A
D B
E C
G C
E A
E D
For motor
Size
Type
1LA9 . . .
56 M . . . . 050 V
. . . . 053 V
63 M . . . . 060
. . . . 063
71 M . . . . 070
. . . . 073
80 M . . . . 080
. . . . 083
90 S . . . . 090
90 L . . . . 096-6K
. . . . 096
100 L . . . . 106
. . . . 107
112 M . . . . 113
132 S . . . . 130
. . . . 131
132 M . . . . 133
. . . . 133
. . . . 134
160 M . . . . 163
. . . . 164
160 L . . . . 166
180 M . . . . 183
180 L . . . . 186
200 L . . . . 206
. . . . 207
No. of
poles
2 and 4
D C
AF
AG
90 25
101
78
78
2 and 4
100 27
101
78
78
2 and 4
111
88
88
2 and 4
120
97
97
74
37
74
37
74
37
75
2 to 6
2 to 6
128
105
105
75
2 to 6
4
2 to 6
2 and 4
2
6
4
6
2 to 6
2
2 to 6
2 and 4
4 and 6
2 and 6
2 to 6
160 42
163
78
123
190 46
216 53
176
194
91
107
216 53
194
254 60
254
279
279
318
300
339
339
388
60
69.5
69.5
83
non-ventilated.
7/4
A Q
F A
D A
A C
A F
B E '
B E
E B
Siemens M 11 2003/2004
320
363
363
402
197
258
258
305
AQ AS
BA
BA BB
BC
BE BE C
CA
CA
37
71
28
87 34
32
18
36
53
124 37
80
28
96 30
32
18
40
124 37
90
27
106 18
32
18
45
66
92
83
32
118 14
32
18
50
54
143 23
32
18
94
134
56 143
120
170 60
140
47
176 39
42
21
136
154
120
140
170 60
250 70
140
140
47
49
176 32
180 39
42
42
21
21
107
154
140
250 70
178
49
218 39
42
21
63 160
1955)
70 179
89 162.5
200.5
89 124.5
162.5
226
127
183
165
57
256 52.5
54
27
108 183
226
258
258
305
127
216
216
252
183
216
216
252
165
152
152
260
250
340
340
340
57
50
50
58.5
300
287
325
355
54
54
54
85
27
27
27
42.5
108
121
121
133
82.5
71
71
96
254
241
279
305
52.5
38
38
45
179
259
221
239
118
Squirrel-cage motors
Dimensions
M 1 -5 2 3 9 a
L L
A S
A G
E y e b o lts fr o m
s iz e 1 0 0 L
B E '
E A
B C
E C
D A
A C
B E
E
G C
H
G A
A Q
E B
F A
A F
A D
L M
L A
E D
K
B
B A
D C
C A
E E
K '
H A
D B
B A
A D '
A B
s iz e s
5 S /M
g fe e t
d r ille d
9 0
h a
e a
h o
S /L
v e
c h
le s
C A
C A '
B
B '
A F '
A
A A
B B
F ra m e
a n d 2 2
h o u s in
w ith 2
a t N D E
B B
B A '
L C
L L
M 1 -5 1 9 8 c
A S
A G
E y e b o lts fr o m
s iz e 1 0 0 L
A D
L M
A Q
F A
E A
D A
A C
A F
B E '
B E
E B
E
G A
E C
G C
D C
E D
D B
HA HH
LC
169
200
74
202.5
228.5
240
232
258
278
74
324
364
389
4343)
4144)
473
5085)
499
551.5
589.5
551.5
589.5
75
15
721
56
69.5
5.8
63
69.5
10
71
63.5
10
80
63.5
90
10
79
100
12
102
112
132
12
15
102
128
132
15
128
160
18
160.5
160
180
180
200
18
18
18
24
160.5
159
159
178
E E
15
15
15
19
19
19
19
19
25
588
628
712
712
768.5
761
841
841
897
LL
74
75
120
120
140
140
165
165
132
132
192
LM
1x M16 x 1.5
1x M25 x 1.5
231.5
1x M16 x 1.5
257.5
1x M25 x 1.5
268
1x M16 x 1.5
1x M25 x 1.5
299.5
1x M16 x 1.5
334.5
1x M25 x 1.5
382.5
1x M16 x 1.5
3
427.5 ) 1x M25 x 1.5
4
409.5 )
458.5
2x M32 x 1.52)
4935)
482.5
2x M32 x 1.52)
505
2x M32 x 1.52)
543
505
2x M32 x 1.52)
543
640.5
680.5
793.5
793.5
850
M3
20
14
10.2 9
M3
20
14
3 10.2
11
M4
23
16
3.5
12.5 11
M4
23
16
3.5
4 12.5
14
M5
30
22
16
14
M5
30
22
5 16
19
M6
40
32
21.5 19
M6
40
32
6 21.5
24
M8
50
40
27
19
M6
40
32
6 21.5
28
M10
60
50
31
24
M8
50
40
8 27
28
38
M10
M12
60
80
50
70
5
5
8
10
31
41
24
38
M8
50
M12 80
40
70
5
5
8 27
10 41
38
M12
80
70
10
41
38
M12 80
70
10 41
90 10
12
45
42
M16 110
90 10
12 45
110 90 10
110 100 5
110 100 5
110 100 5
12
14
14
16
45
51.5
51.5
59
42
48
48
55
M16
M16
M16
M20
2x M40 x 1.52) 42
2
2x M40 x 1.5 )
2 x M40 x 1.5
2 x M40 x 1.5
2 x M50 x 1.5
42
48
48
55
M16 110
M16
M16
M16
M20
110 90 10
110 100 5
110 100 5
110 100 5
Siemens M 11 2003/2004
12
14
14
16
45
51.5
51.5
59
7/5
Squirrel-cage motors
Dimensions
IM B 3
L C
L
M 1 -5 2 2 8 a
L L
E D
E E
O
A S
A G
F A
D A
B C
G C
E C
E B
A Q
D
G A
A C
B E '
B E
A F
A D
L M
D B
D C
K
B
C
B A
E A
C A
K '
H A
A A
B B
A F '
A
A D '
A B
IM B 5 and IM V1 For flange dimensions, see Page 7/20 (Z = Number of fixing holes)
L C
L
M 1 -5 2 2 9 a
H H
E E
L L
A S
A G
A D
L M
For motor
Size
Type
1LA6 . . .
1MA6 . . .
100 L . . . . 106
. . . . 107
112 M . . . . 113
132 S . . . . 130
. . . . 131
132 M . . . . 133
. . . . 134
160 M . . . . 163
. . . . 164
160 L . . . . 166
E C
A Q
G C
D C
E A
E D
No. of
poles
2 to 8
4 and 8
2 to 8
2 to 8
2
4 to 8
6
2 to 8
2 and 8
2 to 8
A F '
A D '
AF
AG
AQ
AS
160 40
BA
BB
BC
BE BE C
CA
HA
164
124
124
121
170
60.5 140 46
180 42
42
21
63 125
100 12
178
194
138
154
138
154
121
141
170
250
60.5 140 46
70.5 140 47
180 34
180 42
42
42
21
21
70 141
89 162.5
112 15
132 17
216 50
256 265
194
194
154
154
141
250
70.5 178 49
218 42
42
21
89 124.5
132 17
254 60
300 320
226
226
183
183
166
250
83
210 63
256 52
54
27
108 183
160 18
254 60
300 320
226
226
183
183
166
250
83
254 63
300 52
54
27
108 139
160 18
Siemens M 11 2003/2004
196 201
164
7/6
F A
D A
A C
B E
G A
D B
A F
B E '
E B
Squirrel-cage motors
Dimensions
M 1 -5 2 3 0 a
L L
A S
A G
B E '
E A
B C
E C
D A
A C
B E
E
G C
H
G A
A Q
E B
F A
A F
A D
L M
K
B
B A
D C
C A
E E
K '
H A
L A
E D
D B
A A
B B
A B
A F '
A D '
L C
L L
M 1 -5 2 3 1 a
A S
A G
A F
E A
A Q
D A
A C
B E '
F A
B E
E B
A D
L M
G A
G C
E C
D C
D B
E D
E E
HH
LC
LL
LM
GA
GC
104.5
12
16
372
438
121
423.5
2x M32 x 1.5
28
M10
60
50
31
24
M8
50
40
27
104.5
130.5
12
12
16
16
393
453.5
461
551.5
121
141
444.5
506
2x M32 x 1.5
2x M32 x 1.5
28
38
M10
M12
60
80
50
70
5
5
8
10
31
41
24
38
M8
M12
50
80
40
70
5
5
8
10
27
41
130.5
12
16
453.5
551.5
141
506
2x M32 x 1.5
38
M12
80
70
10
41
38
M12
80
70
10
41
160
14.5 18
588
721
166
640.5
2 x M40 x 1.5
42
160
14.5 18
588
721
166
640.5
2 x M40 x 1.5
42
M16 110
90
10
12
45
42
M16 110
90
10
12
45
M16 110
90
10
12
45
42
M 16 110
90
10
12
45
Siemens M 11 2003/2004
7/7
Squirrel-cage motors
Dimensions
IM B 3
M 1 -5 1 3 9 b
L M ,
L M '
F A
B C
D B
C
E
G C
B '
B A
B A '
B B
K
C A
C A '
D C
E A
H A
G A
A Q
A C
E C
A G
A S
A F
A D
E E
L C
B E
E B
L , L '
L L
D A
E D
K '
A F '
A
A A
A A
A D '
A B
IM B 5 and IM V1 For flange dimensions, see Page 7/20 (Z = Number of fixing holes)
Type of construction IM B 5 / IM V 1
(only up to frame size 315 M)
E C
A G
A F
A Q
A C
D
E
G C
A H
G A
A S
L M ,
L M '
F A
B E
E B
E E
A D
M 1 -5 1 4 1 c
L C
D A
L L
E D
L , L '
D B
For motor
Size
Type
1MA6 . . .
180 M . . . . 183
180 L
200 L
. . . . 186
. . . . 206
. . . . 207
225 S . . . . 220
225 M . . . . 223
250 M . . . . 253
280 S
. . . . 280
280 M . . . . 283
315 S
. . . . 310
315 M . . . . 313
315 L
. . . . 316
. . . . 317
. . . . 318
E A
H H
No. of
poles
2
4
4 to 8
2
6
2
4 to 8
4 and 8
2
4 to 8
2
4 to 8
2
4 to 8
2
4 to 8
2
4 to 8
2
4 to 8
2
4 to 8
6 and 8
AF
AG
AH
AQ
AS
BA
BA
BB
BC
BE
CA
CA
279
65
82
241* 279
70
108 319 35
75
121 259
279
318
65
80
82
99
241 279*
305
70
85
108 319 35
85 355 42
75
85
121
221
133 239
318
80
99
305
85
355 42
85
133 239
356
356
80
80
436 442 339 339 269 269 264 580 425 100 286* 311
436 442 339 339 269 269 264 580 425 100 286 311*
110 361 25
110 361 25
85
85
149 269
149
244
95
168 283
457 100 557 555 452 452 358 358 338 700 525 120 368* 419 100 151 471 30
95
190 317
457 100 557 555 452 452 358 358 338 700 525 120 368 419* 100 151 471 30
95
190
508 120 628 620 515 515 395 395 405 805 590 134 406* 457 125 171 527 32
90
216 358
508 120 628 620 515 515 395 395 405 805 590 134 406 457* 125 171 527 32
90
216
508 120 628 620 515 515 395 395 405 805 590 134 508
90
216 396
406 100 506 505 427 427 333 333 338 645 470 120 349
7/8
D C
The motors are supplied with two fitted eyebolts conforming to IM B 5, whereby
one can be repositioned to conform to IM V 1 or IM V 3. Care must be taken to avoid
forces perpendicular to the ring.
Siemens M 11 2003/2004
85
85
85
266
307
Squirrel-cage motors
Dimensions
L C
M 1 -5 1 4 2 c
L , L '
E D
D B
B
B A
HA HH K
L2)
K L
180 26
156 15 20
180 26
200 34
156 15 20
175 19 25
200 34
175 19 25
225 34
225 34
174 19 25
174 19 25
250 42
207 24 30
280 42
220 24 30
280 42
220 24 30
315 52
248 28 35
315 52
248 28 35
315 52
248 28 35
715
770
715
819.5
771.5
771.5 819.5
839
809
855
839
935 1010
1010 1080
1010 1080
1114 1185
1144
1114 1185
1144
1254 1325
1284
1284
K
B '
B B
C A
B A '
LC3) LL
841 164
841 164
897 197
897 197
954
924
954
1050
1080
1155
200
200
234
234
1155 234
1260 266
1290
1260 266
1290
1400 266
1430
1430
C A '
E A
E E
H A
G C
B C
C
A Q
A C
E C
F A
D A
B E
A F
A D
L M
E B
G A
A G
A S
K '
D C
A A
A
A B
LM
LM2) O
796.5 885
796.5
853
901
853
901
935
909
955
935
1035 1110
1120 1230
1120 1230
1224 1295
1254
1224 1295
1254
1364 1435
1394
1394
GA
A F '
A A
A D '
2 x M40 x 1.5 48
M 16 110 100
14
51.5 48
M 16 110 100 5
2 x M40 x 1.5 48
2 x M50 x 1.5 55
M 16 110 100
M 20 110 100
5
5
14
16
2 x M50 x 1.5 55
M 20 110 100
16
2 x M50 x 1.5 60
2 x M50 x 1.5 55
60
2 x M63 x 1.5 60
65
2 x M63 x 1.5 65
75
2 x M63 x 1.5 65
75
2 x M63 x 1.5 65
80
2 x M63 x 1.5 65
80
2 x M63 x 1.5 65
80
80
M 20 140 125 10
M 20 110 100 5
140 125 10
M 20 140 125 10
18
16
18
18
M 16
M 16
M 20
M 16
M 20
M 20
M 16
M 20
M 20
M 20 140 125 10
18
20
18
20
18
22
18
22
18
22
22
51.5 48
59
48
55
59
48
55
64
55
59
48
64
55
64
55
69
60
69
60
79.5 65
69
60
79.5 65
69
60
85
70
69
60
85
70
69
60
85
70
85
70
M 20 140 125 10
M 20 140
170
M 20 140
170
M 20 140
170
170
125 10
140
125 10
140
125 10
140
140
GC
14
51.5
14
14
16
110 100 5 14
16
110 100 10 16
110 100 5 14
100 10 16
110 100 5 16
140 125
18
M 20 140 125 10 18
51.5
51.5
59
51.5
59
59
51.5
59
59
64
64
69
64
69
64
74.5
64
74.5
64
74.5
74.5
110 100 5
110 100 5
M 20 140 125 10 18
M 20 140 125 10 18
20
M 20 140 125 10 18
20
M 20 140 125 10 18
20
20
Siemens M 11 2003/2004
7/9
Squirrel-cage motors
Dimensions
A G
A S
L M ,
L M '
G C
B C
H A
G A
A Q
A C
E C
F A
D A
A F
A D
B E
E B
L , L '
L L
E D
M 1 -5 2 1 2 b
IM B 3
D B
E
B
B A
K
B '
B ''
B A '
B B
C A
C A '
C A ''
D C
E A
K '
A F '
A
A A
A A
A D '
A B
IM B 5 and IM V1 For flange dimensions, see Page 7/20 (Z = Number of fixing holes)
L C
E E
A F
A Q
A C
A G
F A
E C
D A
B E
E B
E
G C
A H
G A
A S
L M ,
L M '
A D
Type of construction IM B 5 / IM V 1
(only up to frame size 315 M)
M 1 -5 1 4 1 c
L L
E D
L , L '
D B
For motor
Size
Type
1LG4 . . .
180 M . . . . 183
180 L . . . . 186
. . . . 188
200 L . . . . 206
. . . . 207
. . . . 208
E A
H H
No. of
poles
2 and 4
4 to 8
2 to 8
2 and 6
2 to 8
2 and 6
4 and 8
225 S . . . . 220
4 and 8
225 M . . . . 223
2
4 to 8
. . . . 228
2
4 to 8
250 M . . . . 253
2
4 to 8
. . . . 258
2
4
6 and 8
280 S . . . . 280
2
4 to 8
280 M . . . . 283
2
4 to 8
. . . . 288
2
4
6 and 8
315 S . . . . 310
2
. . . . 310
4 to 8
315 M . . . . 313
2
. . . . 313
4 to 8
315 L4) . . . . 316/317 2
. . . . 316/317 4 to 8
. . . . 318
8
. . . . 318
6
AF
AG
AH
AQ
279
279
279
318
318
318
65
65
65
70
70
70
218
218
218
247
247
247
152
152
152
260
260
260
452
452
452
486
486
486
340
340
340
340
340
340
356
356
356
241*
241
241
305
305
305
279
279*
279*
70 111 328 36
70 111 328 36
70 111 328 36
80 80 355 63
80 80 355 63
80 80 355 63
96 286* 311
96 286 311*
85 110 361 47
85 110 361 47
202*
202
253
177
177
234
177
85 149 218*
85 149 218
96 286 311*
85 110 361 47
339
339
339
378
378
378
363
363
363
402
402
402
262
262
262
300
300
300
262
262
262
300
300
300
218
218
218
247
247
247
AS
71
71
71
96
96
96
BA
BA BB
BC BE
54
54
54
85
85
85
C
121
121
121
133
133
133
CA
CA
164
164*
215*
193
193*
406 100 490 495 392 392 308 308 300 620 470 117 349
406 100 490 495 392 392 308 308 300 620 470 117 349
457 100 540 555 432 432 348 348 300 672 525 118 368* 419
457 100 540 555 432 432 348 348 300 672 525 118 368 419*
457 100 540 555 432 432 348 348 300 672 525 118 368 419*
508 120 610 610 495 495 406 406 379 780 590 154 406* 457
267 216*
110 216 315* 264
508 120 610 610 495 495 406 406 379 780 590 154 406 457*
508 120 610 610 495 495 406 406 379 780 590 154 457 508*
508 120 610 610 495 495 406 406 379 780 590 154 406 457 508* 155 250 666 69
7/10
D C
The motors are supplied with two fitted eyebolts conforming to IM B 5, whereby one
can be repositioned to conform to IM V 1 or IM V 3. Care must be taken to avoid forces
perpendicular to the ring.
Siemens M 11 2003/2004
Squirrel-cage motors
Dimensions
M 1 -5 2 2 2
L , L '
L L
E E
O
E D
F A
D B
B
B A
K
B '
B ''
B B
C A
B A '
E A
C A '
C A ''
H A
G C
B C
C
A Q
A C
E C
D A
B E
A F
A D
L M
E B
G A
A G
A S
K '
D C
A A
A F '
A D '
A A
A B
Squirrel-cage motors
CA H
180
180
180
200
200
200
HA HH K
20
20
20
25
25
25
19
19
19
25
25
25
157
157
157
196
196
196
15
15
15
19
19
19
225 34 196 19 25
225 34 196 19 25
225 34 196 19 25
250 40 237 24 30
250 40 237 24 30
L
668.5
668.5
719.5
720
720
777
720
789
759
789
819
849
887
L2)
LC3) LL
668.5 784
784
719.5 835
754
835
754
835
811
892
835
903
793
873
903
853
933
963
924 1002
1032
924 1002
1102
1032
998 1105
132
132
132
192
192
192
192
192
192
236
LM
758.5
758.5
809.5
810
810
867
810
889
859
889
919
949
987
893
953
1024
280 40 252 24 30
280 40 252 24 30
960
998
1108
1108
1218
1142
1142
1302
987
1057
987
236 1070
1024
1105
1070
1217 307 1182
1247
1212
1217 307 1182
1247
1212
1377 307 1342
1407
1372
1547 307 1512
887
957
887
960
960
315 50 285 28 35 1072
1102
315 50 285 28 35 1072
1102
315 50 285 28 35 1232
1262
236
LM2)
1108
1252
1252
1412
GA
48
48
48
55
55
55
M 16
M 16
M 16
M 20
M 20
M 20
110
110
110
110
110
110
100
100
100
100
100
100
5
5
5
5
5
5
14
14
14
16
16
16
51.5
51.5
51.5
59
59
59
48
48
48
55
55
55
M 16
M 16
M 16
M 20
M 20
M 20
110
110
110
110
110
110
100
100
100
100
100
100
5
5
5
5
5
5
14
14
14
16
16
16
51.5
51.5
51.5
59
59
59
2 x M50 x 1.5 60 M 20
2 x M50 x 1.5 55 M 20
60 M 20
2 x M50 x 1.5 55 M 20
60 M 20
2 x M63 x 1.5 60 M 20
65 M 20
2 x M63 x 1.5 60 M 20
65 M 20
65 M 20
2 x M63 x 1.5 65 M 20
75 M 20
2 x M63 x 1.5 65 M 20
75 M 20
2 x M63 x 1.5 65 M 20
75 M 20
75 M 20
2 x M63 x 1.5 65 M 20
80 M 20
2 x M63 x 1.5 65 M 20
80 M 20
2 x M63 x 1.5 65 M 20
80 M 20
80 M 20
2 x M63 x 1.5 80 M 20
140
110
140
110
140
140
140
140
140
140
140
140
140
140
140
140
140
140
170
140
170
140
170
170
170
125
100
125
100
125
125
125
125
125
125
125
125
125
125
125
125
125
125
140
125
140
125
140
140
140
10
5
10
5
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
18
16
18
16
18
18
18
18
18
18
18
20
18
20
18
20
20
18
22
18
22
18
22
22
22
64
59
64
59
64
64
69
64
69
69
69
79.5
69
79.5
69
79.5
79.5
69
85
69
85
69
85
85
85
55
48
55
48
55
55
60
55
60
60
60
65
60
65
60
65
65
60
70
60
70
60
70
70
70
M 20
M 16
M 20
M 16
M 20
M 20
M 20
M 20
M 20
M 20
M 20
M 20
M 20
M 20
M 20
M 20
M 20
M 20
M 20
M 20
M 20
M 20
M 20
M 20
M 20
110
110
110
110
110
110
140
110
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
100
100
100
100
100
100
125
100
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
5
5
5
5
5
5
10
5
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
16
14
16
14
16
16
18
16
18
18
18
18
18
18
18
18
18
18
20
18
20
18
20
20
20
59
51.5
59
51.5
59
59
64
59
64
64
64
69
64
69
64
69
69
64
74.5
64
74.5
64
74.5
74.5
74.5
Siemens M 11 2003/2004
7/11
Squirrel-cage motors
Dimensions
A G
A S
L M ,
L M '
G C
B C
H A
G A
A Q
A C
E C
F A
D A
A F
A D
B E
E B
L , L '
L L
E D
M 1 -5 2 1 2 b
IM B 3
D B
E
B
B A
K
B '
B ''
B B
B A '
C A
C A '
C A ''
D C
E A
K '
A F '
A
A A
A A
A D '
A B
IM B 5 and IM V1 For flange dimensions, see Page 7/20 (Z = Number of fixing holes)
E E
Type of construction IM B 5 / IM V 1
(only up to frame size 315 M)
Frame size IM V 1
A G
L M ,
L M '
A F
A Q
A C
F A
E C
D A
B E
G C
A H
G A
A S
A D
E B
L C
M 1 -5 1 4 1 c
L L
E D
L , L '
D B
For motor
Size
Type
1LG6 . . .
180 M . . . . 183
E A
H H
No. of
poles
2
4
180 L . . . . 186
4 to 8
200 L . . . . 206
2 and 6
. . . . 207
2 and 6
4 and 8
225 S . . . . 220
4 and 8
225 M . . . . 223
2
4 to 8
. . . . 228
2
4 to 6
250 M . . . . 253
2
4
6 and 8
. . . . 258
2
4 to 6
280 S . . . . 280
2
4 to 8
280 M . . . . 283
2
4
6 and 8
. . . . 288
2
4 to 6
315 S . . . . 310
2
. . . . 310
4 to 8
315 M . . . . 313
8
. . . . 313
2
. . . . 313
4 and 6
315 L4) . . . . 316
2
. . . . 316
4 and 6
. . . . 316/317 8
. . . . 317/318 2
. . . . 317/318 4 and 6
. . . . 318
8
AF
AG
AH
AQ
AS
BA
BA BB
BC BE
CA
CA
279
71 241* 279
70 111 328 36
279
318
318
71 241 279*
96 305
96 305
70 111 328 36
80 80 355 63
80 80 355 63
356
356
96 286* 311
96 286 311*
85 110 361 47
85 110 361 47
54 121 253*
202*
54 121 253
85 133 177
85 133 234
177
85 149 218*
85 149 278
356
96 286 311*
85 110 361 47
215
164
215*
193
253*
406 100 490 495 392 392 308 308 300 620 470 118 349
406 100 490 495 392 392 308 308 300 620 470 118 349
457 100 540 555 432 432 348 348 300 672 525 118 368* 419
457 100 540 555 432 432 348 348 300 672 525 118 368 419*
457 100 540 555 432 432 348 348 300 672 525 118 368 419*
267 216*
110 190 377 226*
508 120 610 610 495 495 406 406 379 780 590 154 406* 457
508 120 610 610 495 495 406 406 379 780 590 154 406 457*
508 120 610 610 495 495 406 406 379 780 590 154 457* 508
508 120 610 610 495 495 406 406 379 780 590 154 457 508*
508 120 610 610 495 495 406 406 379 780 590 154 406 457 508* 155 250 666 69
7/12
D C
The motors are supplied with two fitted eyebolts conforming to IM B 5, whereby one
can be repositioned to conform to IM V 1 or IM V 3. Care must be taken to avoid forces
perpendicular to the ring.
Siemens M 11 2003/2004
Squirrel-cage motors
Dimensions
M 1 -5 2 2 2
L , L '
L L
E E
O
E D
F A
D B
B
B A
K
B '
B ''
B B
C A
B A '
C A '
C A ''
E A
H A
G C
B C
C
A Q
A C
E C
D A
B E
A F
A D
L M
E B
G A
A G
A S
K '
D C
A A
A
A B
A F '
A D '
A A
Squirrel-cage motors
CA H
HA HH K
180 20
157 15 19
180 20
200 25
200 25
157 15 19
196 19 25
196 19 25
225 34
225 34
196 19 25
196 19 25
225 34
196 19 25
250 40
237 24 30
250 40
L2) LC3) LL
237 24 30
719.5
668.5
719.5
756
813
756
789
819
849
869
900
887
957
887
957
835
784
835
835
892
835
903
933
963
983
1013
1002
1102
1032
1102
280 40
252 24 30
960
280 40
252 24 30 1070
280 40
960
252 24 30 1070
1105
1070
1215 236 1180
285 28 35 1072
1102
285 28 35 1102
285 28 35 1232
1262
285 28 35 1232
1262
1217
1247
1247
1377
1407
1377
1407
285 28 35 1372
1402
315 50
315 50
315 50
315 50
513* 315 30
132
LM
132
192
192
192
192
192
236
236
809.5
758.5
809.5
846
903
846
889
919
949
969
1000
987
1057
987
1057
307 1182
1212
307 1212
307 1342
1372
307 1342
1372
LM2) O
GA
GC
14 51.5 48
M 16 110 100
14
51.5
5
5
5
14 51.5 48
16 59
55
16 59
55
M 16 110 100
M 20 110 100
M 20 110 100
5
5
5
14
16
16
51.5
59
59
18
16
18
16
18
18
18
18
18
18
18
20
18
20
20
18
20
18
22
22
18
22
18
22
22
18
22
22
M 20
M 16
M 20
M 16
M 20
M 20
M 20
M 20
M 20
M 20
M 20
M 20
M 20
M 20
M 20
M 20
M 20
M 20
M 20
M 20
M 20
M 20
M 20
M 20
M 20
M 20
M 20
M 20
5
5
5
5
5
5
10
10
5
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
16
14
16
14
16
16
18
18
16
18
18
18
18
18
18
18
18
18
20
20
18
20
18
20
20
18
20
20
59
51.5
59
51.5
59
59
64
64
59
64
64
69
64
69
69
64
69
64
74.5
74.5
64
74.5
64
74.5
74.5
64
74.5
74.5
2 x M50 x 1.5 60 M 20
2 x M50 x 1.5 55 M 20
60 M 20
2 x M50 x 1.5 55 M 20
60 M 20
2 x M63 x 1.5 60 M 20
65 M 20
65 M 20
2 x M63 x 1.5 60 M 20
65 M 20
2 x M63 x 1.5 65 M 20
75 M 20
2 x M63 x 1.5 65 M 20
75 M 20
75 M 20
2 x M63 x 1.5 65 M 20
75 M 20
2 x M63 x 1.5 65 M 20
80 M 20
2 x M63 x 1.5 80 M 20
2 x M63 x 1.5 65 M 20
80 M 20
2 x M63 x 1.5 65 M 20
80 M 20
80 M 20
2 x M63 x 1.5 65 M 20
80 M 20
80 M 20
140
110
140
110
140
140
140
140
140
140
140
140
140
140
140
140
140
140
170
170
140
170
140
170
170
140
170
170
125
100
125
100
125
125
125
125
125
125
125
125
125
125
125
125
125
125
140
140
125
140
125
140
140
125
140
140
10
5
10
5
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
64
59
64
59
64
64
69
69
64
69
69
79.5
69
79.5
79.5
69
79.5
69
85
85
69
85
69
85
85
69
85
85
55
48
55
48
55
55
60
60
55
60
60
65
60
65
65
60
65
60
70
70
60
70
60
70
70
60
70
70
110
110
110
110
110
110
140
140
110
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
100
100
100
100
100
100
125
125
100
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
Siemens M 11 2003/2004
7/13
Squirrel-cage motors
Dimensions
H K
H D
E C
A C
E B
A D
F A
L L
L C
M 1 -5 0 8 4 d
D A
IM B 3
A G
H B
G C
H
H A
B E
B C
G A
D B
E
C
B A
K
B
C A
B B
D C
E A
A A
A
A B
H H
L L
C
H
M 1 -5 0 8 3 e
A Q
A C
B E
'
E B
A G
'
A D
G A
B '
L M
O
D B
For motor
Size
Type
1LA8 . . .
315
. . . . 315
. . . . 317
. . . . 31 .
355
. . . . 353
. . . . 355
. . . . 35 .
400
. . . . 403
. . . . 405
. . . . 407
450
. . . . 453
. . . . 455
. . . . 457
AG
AG
AQ
BA
BB
BC
BE
CA
HA
435
315
28
470
355
35
506
400
35
540
450
42
2
4 to 8
4 to 82)
2
4 to 8
4 to 82)
2
4 to 8
560
120
680
710
570
582
473
481
670
630
180
780
195
110
630
150
780
790
710
730
585
600
750
800
220
980
185
135
710
150
860
880
865
930
775
795
850
900
220
1080
186
100
180
180
200
200
200
224
224
23 )
4 to 8
800
180
980
970
900
980
810
845
950
1000
260
1220
170
100
250
Special designs
M1-5
Cable entry:
Console:
Order code:
downwards
0 degrees
7/14
Siemens M 11 2003/2004
258a
256a
M1-5
M1-5
257a
Cable entry:
Console:
Order code:
upwards
180 degrees
K85
Cable entry:
Console:
Order code:
upwards
0 degrees
plain text
Squirrel-cage motors
Dimensions
L C
L
L L
H D
A C
E C
F A
D A
H K
A D
G C
D C
D B
C
HB
HB
HD
360
290
400
A G
H B
B E
B C
H
H A
E B
G A
HK
B A
K
B
C A
B B
LC
LL
825 170
26
33
285
905 229
33
40
440
400
1020 320
33
40
1370
1400
1420
1595
1625
1690
1785
1825
1495 307
1555
1575
1750 330
1810
1874
1940 550
2010
525
400
1110 320
39
47
LM
K '
E A
A A
A
A B
GA
GC
1500 M 63 x 1.5 65
1530
85
95
1735 M 72 x 2
75
1765
95
100
1935 80
80
1975
110
M 20
M 20
M 24
20 S
24 M
24 M
M 20
M 24
140
170
170
140
170
210
170
210
125
140
140
125
140
180
140
180
18
22
25
20
25
28
22
28
69
90
100
79.5
100
106
85
116
50
70
70
60
80
80
70
90
M 16
M 20
M 20
M 20
2105 80
2145
M 24
170
210
140
180
25
32
95
127
75
100
90
120
M 20
M 20
M 24
110
140
140
140
170
170
140
170
100
125
125
125
140
140
125
140
14
20
20
18
22
22
20
25
53.5
74.5
74.5
64
85
85
74.5
95
M 20
M 24
140
210
125
180
20
28
79.5
106
M1-5
260a
259a
M1-5
Cable entry:
Console:
Order code:
DE / NDE
0 degrees
K83/K84
Cable entry:
Console:
Order code:
DE / NDE
180 degrees
plain text
Siemens M 11 2003/2004
7/15
Squirrel-cage motors
Dimensions
IM B 3
E y e b o lts fr o m
s iz e 1 0 0 L
M 1 -5 1 8 1 c
L C
L
L F
L L
B E
A S
O
A G
A F
A D
L M
A C
A Q
F A
D A
B C
G A
H
K
C
B A
C A
H A
D C
E D
E
G C
E C
E B
D B
E E
E A
K '
A A
B B
A D
A
A B
IM B5 and IM V1 For flange dimensions, see Page 7/20 (Z = Number of fixing holes)
H H
L C
E y e b o lts fr o m
s iz e 1 0 0 L
M 1 -5 0 8 8 e
L F
L L
A S
B E
A G
E D
A D
L M
E B
G C
E C
D C
D B
For motor
Size
Type
1MJ6 . . .
71 M . . . . 070
. . . . 073
80 M . . . . 080
. . . . 083
90 L
. . . . 096
. . . . 097
100 L . . . . 106
. . . . 107
112 M . . . . 113
132 S . . . . 130
. . . . 131
132 M . . . . 133
. . . . 134
160 M . . . . 163
. . . . 164
160 L . . . . 166
No. of
poles
2 and 4
2 to 6
2 to 6
2 to 6
2 to 8
2 to 8
2 to 8
4 and 8
2 to 8
2 to 8
2
4 to 8
6
2 to 8
2 and 8
2 to 8
AQ
AS
BA
BB
BC
BE
CA
90 30
110 58
54
45 144
71
HA
HH
103
10
299
125 36
100 35
125 44
54
50 156
80 10
93.5
140 37
168 183
218
125 35
156 54
54
56 177
90 13
109.5 10
14
383
160 45
140 45
176 50
54
63 185 100 14
112.5 12
16
426
190 50
216 53
140 45
140 49
176 52
180 55
54
54
70 180 112 15
89 228 132 17
121.5 12
144
12
16
16
428
515
216 53
178 49
218 55
54
89 190 132 17
144
12
16
515
254 60
300 323
280
210 57
256 40
54
148
15
19
641
254 60
300 323
314
254 57
300 40
96
148
15
19
641
7/16
A Q
A C
D
G A
F A
D A
E E
E
A F
E A
Siemens M 11 2003/2004
Squirrel-cage motors
Dimensions
L L
B E
M 1 -5 0 8 7 d
L C
L F
A S
O
A G
E D
B C
A Q
E C
E B
G C
D B
D C
H A
G A
F A
D A
A C
A F
A D
L M
K
B
B A
E E
C A
K '
E A
A A
A D
A
A B
B B
IM B 14 For 1MJ6 frame sizes 71 M to 90 L For flange dimensions, see Page 7/20 (Z = Number of fixing holes)
L
L C
M 1 -5 1 1 2 e
L L
B E
A G
A S
O
E D
A D
L M
E B
G C
E C
D B
A Q
A C
F A
D A
E E
F
G A
A F
E A
E
D C
LC
LF
LL
LM
GA
339
132
327
2 x M25 x 1.5
14
M5
30
22
16
14
M5
30
22
386
132
362
2 x M25 x 1.5
19
M6
40
32
21.5
19
M6
40
458
162
434.5
2 x M25 x 1.5
24
M8
50
40
27
24
M8
508
162
477.5
2x M32 x 1.5
28
M 10
60
50
31
28
510
617
162
162
479.5
567.5
2x M32 x 1.5
2x M32 x 1.5
28
38
M 10
M 12
60
80
50
70
5
5
8
10
31
41
617
162
567.5
2x M32 x 1.5
38
M 12
80
70
10
776
383
162
693.5
2 x M40 x 1.5
42
M 16
110
90
10
776
383
190
693.5
2 x M40 x 1.5
42
M 16
110
90
10
ED
FA
GC
16
32
21.5
50
40
27
M 10
60
50
31
28
38
M 10
M 12
60
80
50
70
5
5
8
10
31
41
41
38
M 12
80
70
10
41
12
45
42
M 16
110
90
10
12
45
12
45
42
M 16
110
90
10
12
45
Siemens M 11 2003/2004
7/17
Squirrel-cage motors
Dimensions
IM B 3
M 1 -5 1 3 9 b
L M ,
L M '
F A
B C
D B
G C
C
E
B '
B A
B A '
B B
K
C A
C A '
H A
G A
A Q
A C
E C
D C
E A
A G
A S
A F
A D
E E
L C
B E
E B
L , L '
L L
D A
E D
K '
A A
A F '
A A
A D '
A B
IM B 5 and IM V1 For flange dimensions, see Page 7/20 (Z = Number of fixing holes)
L C
E E
A G
A F
A Q
A C
F A
E C
G C
A H
G A
A S
L M ,
L M '
D A
B E
E B
Type of construction IM B 5 / IM V 1
(only up to frame size 315 M)
A D
M 1 -5 1 4 1 c
L L
E D
L , L '
D B
For motor
Size
Type
180 M 1MJ6 183
180 L 1MJ6 186
200 L 1MJ6 206
1MJ6 207
225 S 1MJ7 220
225 M 1MJ7 223
250 M 1MJ7 253
280 S
1MJ7 280
1MJ7 310
1MJ8 314
1MJ8 316
1MJ8 354
1MJ8 356
1MJ8 357
No. of
poles
2 and 4
4 to 8
2
6
2
4 to 8
4 and 8
2
4 to 8
2
4 to 8
2
4 to 8
2
4 to 8
2
4 to 8
2
4 to 8
2
4 to 8
4 and 6
2
4 to 8
2
4 to 8
4
2
4 to 8
4
The motors are supplied with two fitted eyebolts conforming to IM B 5, whereby one
can be repositioned to conform to IM V 1 or IM V 3. Care must be taken to avoid forces
perpendicular to the ring.
Dimension drawing according to IEC
A
AA AB AC1) AD AD AE AE AE AF
AF AG AH AQ AS
BA
BA BB
BC BE C
CA
279
279
318
82 241* 279
82 241 279*
98.5 305
70 108 319 35
70 108 319 35
85 85 355 42
75
75
85
121 259
121
133 239
318
98.5 305
85
85 355 42
85
133 239
356
356
286* 311
286 311*
85 110 361 25
85 110 361 25
90
90
149 269
149
349
95
168 283
95
190 317
95
190
90
216 358
90
216
494
457
216
494
494
457
508
216
216
475
560
254
475
475
560
630
254
254
475
630
254
7/18
D C
E A
H H
Siemens M 11 2003/2004
Squirrel-cage motors
Dimensions
L , L '
L L
L C
M 1 -5 2 2 1
A E '
E y e b o lts fr o m
s iz e 1 0 0 L
L M
M 1 -5 1 6 2 b
G A
E D
B C
C
D B
B '
B A '
B B
K
C A
C A '
E A
D C
A G
A S
A E ''
G C
E E
B
B A
V ie w A
M 1 -5 1 6 1 b
H A
A E
A F
A D
A E ''
A Q
A C
E C
F A
B E
E B
D A
A E
K '
A A
CA H
HH HA K
180 156 26
221 180 156 26
200 175 34
15 20
15 20
19 25
200 175 34
19 25
225 174 34
244 225 174 34
19 25
19 25
250 207 42
24 30
280 220 42
24 30
24 30
315 248 56
28 35
28 35
315 468 30
28 28
315 468 30
315 513 30
28 28
28 28
355
30
28 28
355
355
30
30
28 28
28 28
355
30
28 28
L2)
LC3) LL
715
770 841 164
715
841 164
771.5 825 897 197
839
954 197
809
855 924 197
839
954
930 1010 1050 234
1080
1010 1080 1155 234
1290
1114 1185 1260 266
1140
1290
1241
1440
1343
1563
1343
1563
1351
1550
1453
1673
1650 1590
1680 1640
1680 1640
1780 1725
1810 1775
1810 1775
LM
A
A B
LM2) O
853
910 2 x M 50 x 1.5
939
2 x M 50 x 1.5
909
955 2 x M 50 x 1.5
939
1404
2 x M 63 x 1.5
1455
1455
2 x M 63 x 1.5
1514
2 x M 63 x 1.5
1565
1750
35 75
1800
1800
35 75
1884
35 75
1934
1934
35 75
A F '
A D '
A A
M 20 140 125
M 20 110 100
140 125
M 20 140 125
M 20 140 125
M 20 140 125
M 20 140
170
M 20 140
170
M 20 140
M 20 170
M 20 170
M 20 140
M 20 170
M 20 140
M 24 170
M 24 170
M 20 140
M 24 170
M 24 170
125
140
125
140
125
140
140
125
140
125
140
140
125
140
140
GA
5 14 51.5 48
5 14 51.5 48
5 16 59
48
55
5 16 59
48
55
10 18 64
55
5 16 59
48
10 18 64
55
10 18 64
55
69
60
10 18 69
60
20 79.5 65
10 18 69
60
20 79.5 65
10 18 69
60
22 85
70
10 18 69
60
22 85
70
18 69
65
22 85
80
22 85
80
18 69
65
22 85
80
20 79.5 75
25 95
90
25 95
90
20 79.5 75
25 95
90
25 95
90
M 16
M 16
M 16
M 20
M 16
M 20
M 20
M 16
M 20
M 20
110 100
110 100
110 100
110 100
110 100
110 100
110 100
140 125
M 20 140 125
M 20 140 125
M 20 140 125
M 20 140 125
M 20
M 20
M 20
M 20
M 20
M 20
M 24
M 24
M 20
M 24
M 24
140
170
170
140
170
140
170
170
140
170
170
125
140
140
125
140
125
140
140
125
140
140
Siemens M 11 2003/2004
5 14 51.5
5 14 51.5
5 14 51.5
16 59
5 14 51.5
16 59
5 16 59
5 14 51.5
16 59
5 16 59
10 18 64
10 18 64
69
10 18 64
69
10 18 64
20 74.5
10 18 64
20 74.5
18 69
22 85
22 85
18 69
22 85
20 79.5
25 95
25 95
20 79.5
25 95
25 95
7/19
Squirrel-cage motors
Dimensions
M 1 -5 2 2 3
M 1 -5 2 2 4
Flange dimensions
In DIN EN 50347, flange FF with clearance holes and flange FT with tapped
holes are assigned to the frame sizes.
The DIN 42948 standard with flanges A and C remains valid. See the assignment table below.
(Z = Number of fixing holes)
Size
Type of construction,
flange type
Flange with
clearance holes (FF/A)
tapped holes (FT/C)
acc. to
acc. to
DIN EN 50 347
DIN 42 948
LA
LE
20
20
20
23
23
23
30
30
30
40
40
40
50
50
50
60
60
60
60
60
60
80
80
80
110
110
110
110
110
110
140
140
140
140
170
100
65
85
115
75
100
130
85
115
165
100
130
165
115
130
215
130
165
215
130
165
265
165
215
300
215
265
300
350
400
80
50
70
95
60
80
110
70
95
130
80
110
130
95
110
180
110
130
180
110
130
230
130
180
250
180
230
250
300
350
500
500
600
140
170
140
170
170
210
170
210
120
80
105
140
90
120
160
105
140
200
120
160
200
140
160
250
160
200
250
160
200
300
200
250
350
250
300
350
400
450
7
M5
M6
10
M5
M6
10
M6
M8
12
M6
M8
12
M8
M8
14.5
M8
M 10
14.5
M8
M 10
14.5
M 10
M 12
18.5
M 12
M 12
18.5
18.5
18.5
3
2.5
2.5
3
2.5
3
3.5
2.5
3
3.5
3
3.5
3.5
3
3.5
4
3.5
3.5
4
3.5
3.5
4
3.5
4
5
4
4
5
5
5
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
8
450
450
550
550
550
660
22
22
22
6
6
6
8
8
8
740
(600)
840
(740)
940
680
(550)
780
(680)
880
800
(660)
900
(800)
1000
22
(24)
22
(24)
22
1080
1000
1150
26
1LA5, 1LA6, 1LA7, 1LA9, 1LG4, 1LG6, 1MA6, 1MA7, 1MJ6, and 1MJ7 motors
56
63
71
80
90
100
112
132
160
180
200
225 2-pole
4-pole to 8-pole
250
280
315 2-pole
4-pole to 8-pole
IM B5 flange
IM B14 standard flange
IM B14 special flange
IM B5 flange
IM B14 standard flange
IM B14 special flange
IM B5 flange
IM B14 standard flange
IM B14 special flange
IM B5 flange
IM B14 standard flange
IM B14 special flange
IM B5 flange
IM B14 standard flange
IM B14 special flange
IM B5 flange
IM B14 standard flange
IM B14 special flange
IM B5 flange
IM B14 standard flange
IM B14 special flange
IM B5 flange
IM B14 standard flange
IM B14 special flange
IM B5 flange
IM B14 standard flange
IM B14 special flange
IM B5 flange
IM B5 flange
IM B5 flange
FF 100
FT 65
FT 85
FF 115
FT 75
FT 100
FF 130
FT 85
FT 115
FF 165
FT 100
FT 130
FF 165
FT 115
FT 130
FF 215
FT 130
FT 165
FF 215
FT 130
FT 165
FF 265
FT 165
FT 215
FF 300
FT 215
FT 250
FF 300
FF 350
FF 400
A120
C 80
C 105
A140
C 90
C 120
A160
C 105
C 140
A200
C 120
C 160
A200
C 140
C 160
A250
C 160
C 200
A250
C 160
C 200
A300
C 200
C 250
A350
C 250
C 300
A350
A400
A450
10
10
11
11
12
13
13
15
16
IM B5 flange
IM B5 flange
IM B5 flange
FF 500
FF 500
FF 600
A550
A550
A660
18
18
22
IM B5 flange
IM B5 flange
25
(22)
25
IM B5 flange
28
IM B5 flange
30
7/20
Siemens M 11 2003/2004
Squirrel-cage motors
Accessories and
repair parts
Repair parts
Siemens supply commitment
for replacement motors and repair parts for
the following periods after delivery of the
motor:
8/2
8/3
8/4
8/7
8/8
8/5
8/6
8/10
8/12
Accessories
Repair parts
1LA5
Frame sizes 180 M to 225 M
1LA7 and 1MA7
Frame sizes 56 M to 90 L
1LA6/7 and 1MA6/7
Frame sizes 100 L to 160 L
1LA6 and 1MA6
Frame sizes 180 M to 200 L
1LA6 and 1MA6
Frame sizes 225 M to 315 L
1LA8 and 1MA8
Frame sizes 315 to 450
1LG4 and 1LG6
Frame sizes 180 M to 250 M
1LG4 and 1LG6
Frame sizes 280 S to 315 L
Siemens M 11 2003/2004
8/1
Squirrel-cage motors
Accessories
Modular technology
The components of the modular
installation concept can be ordered as accessories. The
brake is not permitted to be retrofitted due to its relevance for
safety.
Mounting of separately driven fan for 1LA5, 1LA6, 1LA7 and 1LG motors
Design
Rotary pulse encoder
Size
100 to 225
100 to 225
Separately driven fan
100
incl. mounting parts 1)
112
132
160
180
200
225 2)
250
280
315
315
Separately driven fan and rotary pulse encoder 100
1
incl. mounting parts )
112
132
160
180
200
225 2)
Source:
Ltgert & Co. GmbH
PO Box 42 51
D-33276 Gthersloh
Tel. +49 52 41-74 07-0
Fax +49 52 41-74 07-90
http://www.luetgert-antriebe.de
e-mail:
luetgert-antriebe@t-online.de
HTL version
TTL version
No. of poles
all
all
all
all
all
all
all
all
all
all
all
2
4 to 8
all
all
all
all
all
all
all
Source:
Ltgert & Co. GmbH
PO Box 42 51
D-33276 Gthersloh
Tel. +49 52 41-74 07-0
Fax +49 52 41-74 07-90
http://www.luetgert-antriebe.de
e-mail:
luetgert-antriebe@t-online.de
8/2
Siemens M 11 2003/2004
Order No.
1XP8 0011
1XP8 0012
2CW2 185-8RF14-1AA0
2CW2 210-8RF14-1AA1
2CW2 250-8RF14-1AA2
2CW2 300-8RF14-1AA3
2CW2 300-8RF14-1AA4
2CW2 300-8RF14-1AA5
2CW2 300-8RF14-1AA6
1PP9 063-2LA12-Z A11+K50
1PP9 063-2LA12-Z A11+K50
1PP9 070-2LA12-Z A11+K50
1PP9 063-2LA12-Z A11+K50
2CW2 185-8RF14-2AA0
2CW2 210-8RF14-2AA1
2CW2 250-8RF14-2AA2
2CW2 300-8RF14-2AA3
2CW2 300-8RF14-2AA4
2CW2 300-8RF14-2AA5
2CW2 300-8RF14-2AA6
Couplings
In the majority of applications,
the motor is connected to the
drive by means of a flexible coupling.
Source:
KTR Kupplungstechnik GmbH
Rodder Damm 170
48432 Rheine
Tel. +49 59 71-7 98-0
Fax +49 59 71-7 98-6 98
http://www.ktr.de
Encoder mounting
On delivery or mounted by the
customer.
Options: H74, H79, H75, H80
Hbner Elektromaschinen AG
10967 Berlin
Planufer 92b
Tel. +49 30-6 90 03-0
Fax +49 30-6 90 03-1 04
http://www.huebner-berlin.de
Options H71, H78
Leine & Linde (Deutschland)
GmbH
73430 Aalen
Spitalstr. 19
Tel. +49 73 61-96 16 36
Fax +49 73 61-96 16 35
http://www.leinelinde.de
Squirrel-cage motors
Repair parts
Part No.
Designation
1LA5 183
1LA5 186
1LA5 206
1LA5 207
1LA5 220
1LA5 223
1.40
1.43/6.23
4.07
5.00
5.10
6.20
7.04
7.40
5.10
M1-5093
5.10
7.40
5.00
7.04
6.23
6.20
4.07
1.43
1.40
Siemens M 11 2003/2004
8/3
Squirrel-cage motors
Repair parts
Part No.
Designation
1.40
1.43/6.23
4.07
5.00
5.10
6.20
7.04
7.40
1.61
Order No.
1LY7 113
1LY7 116
63
71
80
90
Type
1LA7 . . . ,
1MA7 . . .
. . . . 06 .
. . . . 07 .
. . . . 08 .
. . . . 09 .
Order No.
Thermoplastic
Metal
1LY7 001
1LY7 002
1LY7 003
1LY7 025
1LY7 201
1LY7 202
1LY7 203
1LY7 225
5.10
5.10
M1-5173b
For motor
Type
1LA7 05 .
to 1LA7 09 .
1MA7 06 .
to 1MA7 09 .
IM B 5
1.40
5.00
5.10
IM B 14
7.40
IM B 3
7.04
6.20
6.23
1.40
8/4
1.43
Siemens M 11 2003/2004
4.07
1.40 size 90
1.61
Squirrel-cage motors
Repair parts
Part No.
Designation
5.10
5.10
8
1.40/6.20 size 100-130 1.61/6.11
5.00
7.40
7.04
IM B 3
IM B 5
6.20
6.23
4.07
5.90
1.43
M1-5174a
1.40
Siemens M 11 2003/2004
8/5
Squirrel-cage motors
Repair parts
Part No.
Designation
1.40
1.43/6.23
4.07
5.00
5.10
6.20
7.04
7.40
M1-5093
5.10
7.40
5.00
7.04
6.23
6.20
4.07
1.43
8/6
1.40
Siemens M 11 2003/2004
Squirrel-cage motors
Repair parts
Designation
Part No.
Designation
5.00
5.10
6.00
8.00
4.20
4.60
3.20
3.60
3.10/4.10
10.10
11.00
12.01
12.70
20.00
Designation
20.30
21.40
21.40
21.40
Part No.
Siemens M 11 2003/2004
8/7
Squirrel-cage motors
Repair parts
For motor
Size
315
355
400
450
Type
1LA8 . . . , 1MA8 . . .
. . . . 315
. . . . 317
. . . . 353
. . . . 355
. . . . 357
. . . . 403
. . . . 405
. . . . 407
. . . . 453
. . . . 455
. . . . 457
Part No.
Designation
Part No.
Designation
5.00
5.10
6.00
7.07
8.00
3.20
3.60
4.20
4.60
3.10/4.10
11.04
11.05
12.01
12.70
20.00
Fan cowl
Protective cover
Terminal box,
complete with terminals
Designation
20.30
21.40
8/8
Siemens M 11 2003/2004
Part No.
Designation
20.00
20.30
Squirrel-cage motors
Repair parts
Siemens M 11 2003/2004
8/9
Squirrel-cage motors
Repair parts
225 S
225 M
250 M
Standard version
8/10
Siemens M 11 2003/2004
Part No.
Designation
Part No.
Designation
1.00
1.40
1.43
1.58
1.60
1.61
1.65
1.67
1.68
1.69
3.00
4.00
4.07
4.18
4.35
4.40
4.41
5.00
5.03
5.10
5.33
5.34
5.35
5.44
5.51
Drive-end bearing
Bearing shield
Shaft seal
Spring lock washer
Rolling contact bearing
Sealing plugs
Bearing cap
Outer bearing cap
Spun washer
Compression spring
Rotor, complete
Stator, complete
Housing feet (size 180 right, left)
Rating plate
Washer
Washer
Earthing strap
Terminal box, complete
Seal (size 200, string seal)
Terminal board, complete
Non-rotating washer
Terminal clamp
Grommets
Terminal box, top section
Nut
5.52
5.70
5.71
5.72
5.83
5.84
5.89
5.94
5.95
5.96
5.97
5.99
6.00
6.10
6.20
6.23
6.24
6.65
6.66
6.67
7.00
7.04
7.40
7.41
7.49
Terminal link
Terminal clamp
Outer bearing cap
Spun washer
Gasket
Terminal box cover
Screw
Screw
Terminal
Mounting rail
Brace, complete
Contact plate
Bearing, non-drive end
Rolling contact bearing
Bearing shield
Shaft seal
Bearing cap
Grease nipple
Rubber socket
Lubrication pipe
Ventilation, complete
Fan
Fan cowl
Bracket
Screw
Squirrel-cage motors
Repair parts
gk 330
gk 430
gt 431
gt 520
Siemens M 11 2003/2004
8/11
Squirrel-cage motors
Repair parts
Standard version
8/12
Siemens M 11 2003/2004
Part No.
Designation
Part No.
Designation
1.00
1.40
1.43
1.58
1.60
1.61
1.65
1.67
1.68
1.69
3.00
4.00
4.07
4.18
4.35
4.40
4.41
5.00
5.03
5.10
5.33
5.34
5.35
5.44
5.51
Drive-end bearing
Bearing shield
Shaft seal
Spring lock washer
Rolling contact bearing
Sealing plugs
Bearing cap
Outer bearing cap
Spun washer
Compression spring
Rotor, complete
Stator, complete
Housing feet (size 180 right, left)
Rating plate
Washer
Washer
Earthing strap
Terminal box, complete
Seal (size 200, string seal)
Terminal board, complete
Non-rotating washer
Terminal clamp
Grommets
Terminal box, top section
Nut
5.52
5.70
5.71
5.72
5.83
5.84
5.89
5.94
5.95
5.96
5.97
5.99
6.00
6.10
6.20
6.23
6.24
6.65
6.66
6.67
7.00
7.04
7.40
7.41
7.49
Terminal link
Terminal clamp
Outer bearing cap
Spun washer
Gasket
Terminal box cover
Screw
Screw
Terminal
Mounting rail
Brace, complete
Contact plate
Bearing, non-drive end
Rolling contact bearing
Bearing shield
Shaft seal
Bearing cap
Grease nipple
Rubber socket
Lubrication pipe
Ventilation, complete
Fan
Fan cowl
Bracket
Screw
Squirrel-cage motors
Repair parts
gt 520
gt 620
Siemens M 11 2003/2004
8/13
Squirrel-cage motors
Repair parts
Notes
8/14
Siemens M 11 2003/2004
Squirrel-cage motors
Appendix
Environment, resources and recycling
Siemens AG has committed itself to protecting
the environment and conserving valuable natural resources. This applies both to production
and to the products we sell. As early as the development phase, the possible impact of future
products and systems on the environment is taken into consideration. Our aim is to prevent environmental pollution or, at least, reduce it to a
minimum and in doing so, look beyond existing
regulations and legislation. The most important
activities in the protection of the environment
are:
We are constantly endeavoring to minimize
the environmental impact of our products as
well as their consumption of energy and resources over and above the statutory environmental protection regulations.
We take every possible step to prevent damage to the environment.
A/2
Overview of
MICROMASTER 410/420/430/440
A/3
A/4
A/5
A/7
A/8
A/9
Subject index
A/11
A/14
A/6
Siemens M 11 2003/2004
A/1
Squirrel-cage motors
Appendix
The complete product spectrum with ordering data, technical details and explanations is
included in Catalogue DA 51.2.
http://www.siemens.com/
micromaster
MICROMASTER 410
"Price-conscious"
For variable speeds with
3-phase motors on single-phase
supply systems, e.g. for pumps,
fans, advertising panels, cabinets, gate drives and dispensing
machines
MICROMASTER 420
"Universal"
For 3-phase supply systems as
well as optional fieldbus interfacing, e.g. in conveyor belts, material conveyors, pumps, fans and
machine tools
MICROMASTER 430
"Optimized for pumps and
fans"
With optimized operator panel
(manual/automatic changeover)
adapted software functions and
optimum power utilization
Output range
Voltage ranges
0.12 kW to 0.75 kW
1 AC 100 V to 120 V
1 AC 200 V to 240 V
0.12 kW to 11 kW
1 AC 200 V to 240 V
3 AC 200 V to 240 V
3 AC 380 V to 480 V
7.5 kW to 250 kW
3 AC 380 V to 480 V
Closed-loop control
V/f characteristic
Multipoint characteristic (parameterizable V/f characteristic)
FCC (flux current control)
V/f characteristic
Multipoint characteristic (parameterizable V/f characteristic)
FCC (flux current control)
V/f characteristic
Multipoint characteristic (parameterizable V/f characteristic)
FCC (flux current control)
Process control
Internal PI controller
Inputs
3 digital inputs
1 analog input
3 digital inputs
1 analog input
Outputs
1 relay output
Main features
Automation
link
Other
features
Natural ventilation
(no fan)
Position of the connections as
for conventional switching elements (e.g. contactors). Also
available with flat plate heatsink.
1 analog output
1 relay output
The ideal partner for your automation tasks, for SIMATIC S7200 as well as for SIMATIC S7300/400 (TIA) and SIMOTION
BICO technique
Examples
MICROMASTER
A/2
Siemens M 11 2003/2004
MICROMASTER 440
"Comprehensive"
With finely tuned vector control
(with and without sensor feedback) for numerous applications
in sectors such as conveyor systems, textiles, elevators, hoisting
gear and mechanical engineering
0.12 kW to 250 kW
1 AC 200 V to 240 V
3 AC 200 V to 240 V
3 AC 380 V to 480 V
3 AC 500 V to 600 V
V/f characteristic
Multipoint characteristic (parameterizable V/f characteristic)
FCC (flux current control)
Vector Control
Internal PI controller (auto tuning)
6 digital inputs
2 analog inputs
1 PTC/KTY input
2 analog outputs
3 relay outputs
The ideal partner for your automation tasks, for SIMATIC S7200 as well as for SIMATIC S7300/400 (TIA) and SIMOTION
3 selectable drive data sets
Integral brake chopper
(up to 75 kW)
Torque control
Squirrel-cage motors
Appendix
http://www.siemens.com/
combimaster
MICROMASTER 411
COMBIMASTER 411
"Decentralized"
For a wide range of drives simple stand-alone applications from pumps and fans through to multiple conveyor drives in networked
control systems.
Output range
0.37 kW to 3 kW
Voltage ranges
3 AC 380 V to 480 V
Housing/
CS B
71 100
frame sizes
CS C
90/100
Types of
IM B 3
construction
IM B 5
IM V 1 (without protective cover)
IM V 1 (with protective cover)
IM B 14 (with standard flange)
IM B 14 (with special flange)
IM B 35
Degree of protection IP66
IP55
Other technical
V/f characteristic
features
Multipoint characteristic (parameterizable V/f characteristic)
FCC (flux current control)
Internal PI controller
3 digital inputs
1 analog input
1 relay output
Compound braking for controlled rapid braking
NEW: ECOFAST variants with connectors for the power supply and communication interfaces and motor connections to permit fast and
easy replacement for time-critical applications. The ECOFAST variants are fully compatible with the ECOFAST technology systems.
Main features
Examples
MICROMASTER
Examples
COMBIMASTER
Siemens M 11 2003/2004
A/3
Squirrel-cage motors
Appendix
Liquid-cooled motors
A/4
Siemens M 11 2003/2004
Squirrel-cage motors
Appendix
Siemens M 11 2003/2004
A/5
Squirrel-cage motors
Data transfer via EDIFACT allows the whole procedure from selection through ordering to tracking of the order to be carried out online
via the Internet.
Numerous functions are available to support you.
For example, powerful search functions make it easy to find the required products, which can be immediately checked for availability.
Customer-specific discounts and preparation of quotes can be carried out online as well as order tracking and tracing.
Please visit the A&D Mall on the Internet under:
http://www.siemens.com/automation/mall
A/6
Siemens M 11 2003/2004
Squirrel-cage motors
Service On Site
With Service On Site we offer
services for startup and maintenance, essential for ensuring
system availability.
In Germany
0180 50 50 444 2)
Online Support
http://www.siemens.com/
automation/service&support
In Germany
0180 50 50 448 2)
Technical Support
systems.
Tel.: +49 (0)180 50 50 222
Fax: +49 (0)180 50 50 223
E-Mail:
adsupport@siemens.com
Technical Consulting
Support in the planning and
designing of your project from
detailed actual-state analysis,
target definition and consulting
on product and system questions right to the creation of the
automation solution. 1)
1) Get in touch with the sales contact in your region for questions about these
services. Our Helpline (tel.: +49 (0) 180 50 50 111) will also put you through
to the right contact or just visit our Internet site.
2) For country-specific telephone numbers go to our Internet site at:
http://www.siemens.com/automation/service&support
Siemens M 11 2003/2004
A/7
Squirrel-cage motors
edge Manager for targeted searches for solutions. The CD-ROM will
be updated every 4 months.
Just the same as our online offer in the Internet, the Service & Support Knowledge Base on CD comes complete in 5 languages (German, English, French, Italian, Spanish).
You can order the Service & Support Knowledge Base CD
from your Siemens contact.
Order no. 6ZB5310-0EP30-0BA2
Orders via the Internet
(with Automation Value Card or credit card) at:
http://www.siemens.com/automation/service&support
in the Shop domain.
Detailed information on the services offered is available on our Internet site at:
Small card great support
http://www.siemens.com/automation/service&support
The Automation Value Card is an integral component of the comprehensive service concept with which Siemens Automation and Drives
accompanies your whole automation project in each phase.
The card number and PIN are printed on the back of the Automation
Value Card. When you first receive your card, the PIN is hidden under a scratch field which ensures that nothing has been debited to
your card.
A/8
Siemens M 11 2003/2004
Technical Support
Priority
Priority processing for urgent cases
24 h
Availability round the clock
Extended
Technical consulting for complex questions
Support Tools in the Support Shop
System
Tools that can be used directly for configuration, analysis
Utilities
and testing
Applications
Complete topic solutions including ready-tested software
Functions &
Adaptable blocks for accelerating your developments
Samples
Squirrel-cage motors
Appendix
Subject index
Page
A
A&D in the WWW
A&D Mall
Abnormal frequencies
Abnormal voltages
Accessories
Aluminium housing
Anti-condensation heating
Appendix
Approvals
Automation Value Card
Axial loads
A/6
A/6
2/11
2/11
Section 8
3/2 to 3/11, 4/2
2/17
Section A
6/4
A/7
2/40 to 2/43
B
Balance
Bearing diagrams
Bearing selection
Bearing service life
Bearing shields
Bearing system
Bearings
Bearings for increased cantilever forces
Brakes
2/27
2/34 to 2/35
2/30 to 2/33
2/29
6/5
2/30
2/29 to 2/35, 2/44, 6/5
2/37
2/50 to 2/55
C
Cable entry
Cantilever forces
Cast iron housings
CEMEP
Certificates
Certification
Certification procedure
Circuit
Classification societies
COMBIMASTER 411
Condensation water holes
(degrees of protection)
Conditions of sale
Conditions of sale and delivery
Configuration of brake motors
Connection
Connection method
Connection of motors
Converter mounting
Converter-fed operation
Coolant temperature
Cooling
Coupling to gearboxes
Couplings
CSA approval
Currents
Customized motors
2/9
2/36 to 2/39
3/12 to 3/20, 4/3 to 4/5
3/2, 3/5, 3/12, 3/16
6/3
4/7, 5/7, 6/15
6/4
2/18 to 2/22
6/2
2/46, A/3
2/23
A/14
A/14
2/55
2/18 to 2/22
65/5
2/44
3/27
2/44
2/14, 2/15
2/23
2/23
8/2
2/8
2/10 to 2/12
A/4
Electronic Catalogue SD 01
Encoder mounting
Energy Efficiency Verification
Energy Policy Act
Energy-saving motors
Energy-saving motors with European
efficiency classification to EU/CEMEP
Energy-saving range
Environment
EPACT
Ex zones
Explosion-proof enclosure
Explosion-proof enclosure "d"
Export of low voltage motors to China
Export regulations
Eyebolts
Page
2. Inside cover, 2/6
8/2
2/8
2/8
3/2 to 3/6, 3/12 to 3/17
2/8
2/6
A/1
3/6, 3/18
3/26
Section 5
2/9
2/7
A/14
2/24
F
F200
F300
F400
Forced-air cooled motors
Foundation blocks
Frame design
Frequencies
Frequency
Further external mountings for
1LA/1LG motors
2/58 to 2/59
G
General information
Grease life
2/2 to 2/6
2/44
H
Hazardous areas
Heat extraction machinery
High Efficiency
Higher efficiency
2/9
6/4
3/5, 3/17
6/3
I
Improved Efficiency
Increased coolant air temperature
Increased output
Increased safety
Increased safety "e"
Installation altitude
Insulation
Insulation arrangement
Interactive catalogues
Internet links
Introduction
K
Knowledge base on CD-ROM
A/7
L
Lubricants
6/5
D
Degrees of protection
Design and certification of
explosion-proof motors in accordance
with directive 94/9/EC (ATEX)
Designs
Dimension sheet generator
Dimensions
Direction of rotation
Distributed drive systems
Double pole-changing
Driving fans
2/9
2/3, 2/4
7/1
2/56, 2/57, Section 7
2/24
2/46 to 2/47, 3/26
3/9, 3/10
3/10, 3/11
M
Marine motors
Marine version
Maximum axial loading
Maximum cantilever forces
Maximum load on the shaft end
Mechanical design
E
ECOFAST
EEx de IIC
EEx e II
eff1
eff2
Efficiency
Electrical design
2/46
Section 5
Section 4
3/5, 3/17
3/2, 3/12, 3/13
2/16
2/10 to 2/22
6/7 to 6/10
6/7 to 6/10
3/9 to 3/11, 6/11 to 6/14
6/7, 6/8, 6/11, 6/12
8/2
2/23
2/10 up to 2/12
6/4
2/23
6/2, 6/3
3/26, 4/7, 5/7
2/40 to 2/43
2/36 to 2/39
6/6
2/23 to 2/43, 3/27,
4/7, 5/7, 6/15, 6/2
2/45
2/44
A/2, A/3
2/46
2/47
6/5
2/8
2/48 to 2/57, 3/27, 8/2
Siemens M 11 2003/2004
A/9
Squirrel-cage motors
Appendix
Subject index
Motor series
Motor temperature detection
Motors for the U.S. market
Mountings
Mountings for 1LA/1LG motors
Page
2/17, 3/25, 4/6, 5/6,
6/15, 6/3
6/4
2/17, 2/44
2/8
3/27
2/58 to 2/59
N
National standards
NEMA
Noise for mains-fed operation
Noise generation
Notes on commissioning
Notes on safety
Notes on the dimensions
Number of poles
2/7
2/8
2/28
2/44
3/28, 6/15
3/28, 6/15
7/1
6/4
Motor protection
O
Online Support
Operating mode
Operation with SIMOVERT
MASTERDRIVES
Optimization
Order No.
Ordering data
Output tables
Outputs
Overview of "Special designs"
P
Packaging
Packaging dimensions
Packaging weights
Paint finish
Power factor
Prelubrication
Project engineering
Project planning aids
R
Rated currents
Rated output
Rated torque
Rating plates
Recycling
Regulations
Repair
Resources
Restarting
Rotary pulse encoder 14XP8 001
Rotary pulse encoder HOG10 D 1024 l
Rotary pulse encoder HOG9 D 1024 l
Rotary pulse encoder LL 861 900220
S
SD 01
SD Configurator
Sector solutions
Selection data
Self-cooled motors
Separately driven fan
Service & Support
Service locally
Shaft extensions
A/10
Siemens M 11 2003/2004
A/7
6/4
3/21 to 3/24
A/7
2/2
Sections 3, 4, 5, 6
2/13, 2/14
2/13 to 2/15
2/3, 2/4
2/5
2/5
2/5
2/5, 3/25, 4/6, 5/6, 6/15,
6/3, 6/5
2/16
2/29
A/7
2/6
2/12 to 2/13
6/4
2/16
2/15
A/1
2/7 to 2/9, 6/2, 6/4
A/7
A/1
2/17
2/48
2/59
2/59
2/58
2. Inside cover, 2/6
2. Inside cover, 2/6
Section 6
Sections 3, 4, 5, 6
6/9, 6/10, 6/13, 6/14
2/49
A/7
A/7
2/27
Speed
Speed limits
Spring-operated brake
Squirrel-cage motors 1LA, 1LG
Squirrel-cage motors 1MA
Squirrel-cage motors 1MJ
Standard voltages
Standards
Standards and specifications
Supervised construction approvals
Page
3/21 to 3/24
8/2
6/4
6/4 to 6/15
A/7
A/7, Section 8
2/3, 2/4, 3/25 to 3/28,
4/6 to 4/7, 5/6 to 5/7,
6/15
2/24
2/45
2/53, 2/54
Section 3
Section 4
Section 5
2/10
2/7 to 2/9, 6/2, 6/4
2/7
6/4
T
Taper pins
Technical Consulting
Technical design
Technical information
Technical Support
Temperature sensor
Temperature/time class F200
Temperature/time class F300
Temperature/time class F400
Terminal boxes
Tolerances
Tolerances for electrical data
Trade marks
Triple pole-changing
Types of construction
Type of protection "n"
Type of protection EEx de IIC
Type of protection EEx e II
8/2
A/7
6/4
Section 2
A/7
2/17
6/7 to 6/10
6/7 to 6/10
6/11 to 6/14
2/18 to 2/22
2/7 to 2/9
2/7
2. Inside cover
3/11
2/25 to 2/26
2/9
2/9, Section 5
2/9, Section 4
SIMOVERT MASTERDRIVES
Slide rails and tensioning screws
Smoke extraction machinery
Smoke extraction motors
Software engineering
Spare parts
Special designs
U
UL approval
Upgrading
Use in smoke and heat extraction
machinery
Useful Internet links
6/4
2/6
V
Ventilation
Vibration severity
VIK design
Voltage
Voltages
2/23, 2/44
2/27
2/9
6/4
2/10 to 2/12
W
Water drain holes
Weights
Winding protection
Windings
6/5
2/57
6/3
2/17, 3/25, 4/6, 6/15
2/8
A/7
Squirrel-cage motors
Appendix
Page
3/2, 3/3, 3/9, 3/10, 3/11, 3/22,
6/9, 6/10
3/2, 3/3, 3/9, 3/10, 3/11, 3/22,
6/9, 6/10
3/2, 3/3, 3/22, 6/9, 6/10
Order No.
1LG6
1LG6 18.
1LG6 20.
1LG6 22.
1LG6 25.
1LA8
1LA8 31.
1LA8 31.
1LA8 35.
1LA8 35.
1LA8 40.
1LA8 40.
1LA8 45.
1LA8 45.
1LA9
1LA9 05.
1LA9 06.
1LA9 07.
1LA9 08.
1LA9 09.
1LA9 10.
1LA9 11.
1LA9 13.
1LA9 16.
1LA9 18.
1LA9 20.
1LG4
1LG4 18.
1LG4 20.
1LG4 22.
1LG4 25.
1LG4 28.
1LG4 31.
1LG6 28.
1LG6 31.
Page
3/16, 3/17, 3/18, 3/19, 3/23,
3/24, 6/13, 6/14
3/16, 3/17, 3/18, 3/19, 3/23,
3/24, 6/13, 6/14
3/16, 3/17, 3/18, 3/19, 3/23,
3/24, 6/13, 6/14
3/16, 3/17, 3/18, 3/19, 3/23,
3/24, 6/9, 6/10, 6/13, 6/14
3/16, 3/17, 3/18, 3/19, 3/23,
3/24, 6/9, 6/10, 6/13, 6/14
3/16, 3/17, 3/18, 3/19, 3/23,
3/24, 6/9, 6/10, 6/13, 6/14
1MA6
1MA6 10.
1MA6 11.
1MA6 13.
1MA6 16.
1MA6 18.
1MA6 20.
1MA6 22.
1MA6 25.
1MA6 28.
1MA6 31.
1MA7
1MA7 06.
1MA7 07.
1MA7 08.
1MA7 09.
4/2
4/2
4/2
4/2
1MA7 10.
1MA7 11.
1MA7 13.
1MA7 16.
4/2
4/2
4/2
4/2
1MJ1
1MJ1 35.
1MJ1 40.
1MJ1 45.
1MJ6
1MJ6 07.
1MJ6 08.
1MJ6 09.
1MJ6 10.
1MJ6 11.
1MJ6 13.
1MJ6 16.
1MJ6 18.
1MJ6 20.
1MJ7
1MJ7 22.
1MJ7 25 .
1MJ7 28.
1MJ7 31.
1MJ8
1MJ8 31.
1MJ8 35.
1PP5
1PP5 18.
1PP5 20.
1PP5 22.
6/7, 6/8
6/7, 6/8
6/7, 6/8
Siemens M 11 2003/2004
A/11
Squirrel-cage motors
Appendix
Page
Order No.
Page
1PP6
1PP6 10.
1PP6 11.
1PP6 13.
1PP6 16.
6/11, 6/12
6/11, 6/12
6/11, 6/12
6/11, 6/12
1PP7
1PP7 08.
1PP7 09.
1PP7 10.
1PP7 11.
6/7, 6/8
6/7, 6/8
6/7, 6/8
6/7, 6/8
1PP6 18.
1PP6 20.
1PP6 22.
1PP6 25.
6/11, 6/12
6/11, 6/12
6/11, 6/12
6/7, 6/8, 6/11, 6/12
1PP7 13.
1PP7 16.
6/7, 6/8
6/7, 6/8
1PP6 28.
1PP6 31.
A/12
Siemens M 11 2003/2004
Squirrel-cage motors
Appendix
Notes
Siemens M 11 2003/2004
A/13
Squirrel-cage motors
Appendix
Export regulations
The products listed in this catalogue may be subject to European/
German and/or US export regulations.
Therefore, any export requiring a license is subject to approval by
the competent authorities.
According to current provisions, the following export regulations
must be observed with respect to the products featured in this
catalogue:
AL
ECCN
6ZB5310-0KR30-0BA0
(for customers based in the Federal Republic of Germany)
6ZB5310-0KS53-0BA0
(for customers based outside of the Federal Republic of Germany)
or download them from the Internet:
www.siemens.com/automation/mall
(Germany: A&D Mall Online-Help System)
Responsible for
Technical contents:
Siemens AG, A&D SD SM
General editing:
Siemens AG, A&D PT 5, Erlangen
Siemens AG
Automation & Drives
Standard Drives
P.O. Box 32 69
D-91050 Erlangen
A/14
Siemens M 11 2003/2004
Order No.:
E86060-K1711-A101-A3-7600
Printed in Germany
KG K 1203 25.0 E 176 En/422201
Catalogues of the
Catalogue
CA 01
NC 60
Communication-Capable Controlgear,
Controlgear with SIRIUS, SIGUARD Safety Systems,
Control and Signalling Devices, Switchgear,
Transformers and DC Power Supplies,
Main- and EMERGENCY-STOP Switches,
Control Switches, Terminal Blocks
NC Z
Drive Systems
Variable-Speed Drives
Catalogue
NS K
NS BERO
NS PS
SENTRON WL
NS WL
PM 10
DC Motors
DA 12
DA 12.1
DA 12.2
DA 21.1
DA 21.2
DA 22
MP 12
MP 20
DA 45
MP 31
SIEMOSYN Motors
DA 48
WT 01
DA 51.2
WT 02
DA 51.3
PA 10
DA 63
PA 11
DA 65.10
DA 65.11
PA 20
DA 65.3
DA 65.4
ST 45
ST 50
ST 70
Low-Voltage Three-Phase-Motors
Project Manual
M 10
M 11
NC 60
FI 01
ST PCS 7
ST PCS 7.A
ST DA
MP 35
MP 35.1/.2
Systems Engineering
Power supplies SITOP power
KT 10.1
KT 10.2
KT 21
KT 51
HE 1
ET A1
ET A3
ET B1
ET D1
ET G1
System Solutions
Applications and Products for Industry are part of the
interactive catalog CA 01
ST 80
PLT 111
PLT 112
PLT 123
PLT 130
IK PI
The information provided in this catalogue contains descriptions or characteristics of performance which in case of actual
use do not always apply as described or which may change as
a result of further development of the products. An obligation
to provide the respective characteristics shall only exist if
expressly agreed in the terms of contract. Availability and
technical specifications are subject to change without notice.
Siemens AG
Automation and Drives
Standard Drives
Postfach 32 69, D-91050 Erlangen
www.siemens.com/motors
Low-Voltage Motors