Sie sind auf Seite 1von 4

HARCO SDR-26 PVC GASKETED SEWER FITTINGS

DESIGN DATA
Applicable Standards
Fittings:
Materials:
Joints:
Gaskets:
Wall Thickness:
Installation:

TEE- WYE GxGxG


ASTM D-3034, F-1336
ASTM D-1784
ASTM D-3212
ASTM F-477
SDR-26
ASTM D-2321

BELL SPECIFICATION
A
B

SPIGOT
O.D.

SIZE

STYLE

Spigot O.D.

4
6
8
10
12
15

Molded
Molded
Molded
Fab/Molded
Fab/Molded
Fab

2.72
3.47
4.02
7.5
7.5
7.5

1.8
2.5
3.0
4.8
4.8
4.8

5.18
7.37
9.62
10.6/10.8
12.6/14.0
17.1

4.215
6.275
8.40
10.50
12.50
15.3

SIZE
4X4
6X4
6X6
8X4
8X6
8X8
10X4
10X6
12X4
12X6
15X4
15X6

STYLE

PART No.
505-0404
505-0604
505-0606
505-0804
505-0806
505-0808
505-1004
505-1006
505-1204
505-1206
505-1504
505-1506

Fab
Fab
Fab
Molded
Molded
Fab
Molded
Molded
Molded
Molded
Fab
Fab

C
4.0
5.2
5.2
5.5
6.1
15.0
13.8
14.2
14.7
15.2
16.1
16.5

(Molded fitting Shown)


L
WT. (approx.)
21.1
2.4
21.6
2.6
23.7
6.0
16.6
9.9
16.6
10.7
23.6
17.0
26.0
20.0
29.0
20.0
27.0
28.0
30.0
34.0
29.0
40.0
32.0
42.0

TEE GxGxG

DOUBLE WYE GxGxG


L

C
(Molded fitting Shown

SIZE

PART No.

STYLE

WT. (appox.)

4X4
6X4
6X6
8X4
8X6

504-0404
504-0604
504-0606
504-0804
504-0806

Fab
Molded
Molded
Fab
Fab

5.2
7.1
7.8
8.0
9.2

11.8
16.0
17.0
15.0
18.5

3.0
5.6
9.3
9.0
12.0

CALL FOR OTHER SIZES, CONFIGURATIONS & GASKET MATERIALS.

NOTES:
All lay lengths & weights are approximate and are subject to
change without notice.
Fabricated fitting configurations may vary.
CAUTION: Vertical risers are not recommended.
Vertical risers are subject to problems without special consideration
of soil/pipe interaction, dead & live loads, and installation procedures.

(Molded fitting Shown)

SIZE

PART No.

STYLE

WT. (appox.)

4X4
6X4
6X6
8X4
8X6
8X8
10X4
10X6
10X8
10X10
12X4
12X6
12X8
12X10
12X12
15X4
15X6
15X8
15X10
15X12
15X15

512-0404
512-0604
512-0606
512-0804
512-0806
512-0808
512-1004
512-1006
512-1008
512-1010
512-1204
512-1206
512-1208
512-1210
512-1212
512-1504
512-1506
512-1508
512-1510
512-1512
512-1515

Fab
Fab
Fab
Fab
Molded
Fab
Fab
Fab
Fab
Fab
Fab
Fab
Fab
Fab
Fab
Fab
Fab
Fab
Fab
Fab
Fab

7.0
8.0
9.5
10.5
10.5
12.7
12.7
13.2
13.7
15.2
13.6
14.1
14.6
16.1
16.6
15.0
15.8
16.0
17.5
18.0
19.0

13.3
14.0
18.3
19.3
22.3
25.5
23.5
25.5
27.5
29.5
24.5
26.5
28.5
30.5
32.5
26.5
28.5
30.5
32.5
34.5
37.5

3.0
5.0
7.0
10.0
10.0
14.0
18.0
20.0
23.0
29.0
27.0
28.0
32.0
38.0
43.0
38.0
37.0
46.0
51.0
57.0
77.0

THE HARRINGTON CORPORATION


P.O. BOX 10335 LYNCHBURG VIRGINIA 24506 PLANT 3721 COHEN PLACE LYNCHBURG VIRGINIA 24501
PHONE: (434) 845-7094 FAX: (434) 845-8562 E-MAIL: sales@harcofittings.com
Form 134 5/21/10

HARCO SDR-26 PVC GASKETED SEWER FITTINGS


DESIGN DATA
LINE COUPLING (w/ Stop)

CAP
L

(Molded fitting Shown)

SIZE
4
6
8
10
12
15

PART No.
549-040
549-060
549-080
549-100
549-120
549-150

STYLE
Molded
Molded
Fab
Fab
Fab
Fab

L
2.7
3.5
4.0
10.5
12.0
14.0

WT. (approx.)
1.2
2.5
6.0
11.0
18.0
27.0

MANHOLE ADAPTERS (SINGLE BELL)

(Molded fitting Shown)

SIZE

PART No.

4
6
8
10
12
15

508-040
508-060
508-080
508-100
508-120
508-150

STYLE

WT. (appox.)

Molded
Molded
Molded
Fab
Fab
Fab

8.5
7.1
8.3
17.0
17.5
19.5

1.1
3.0
4.4
13.0
20.0
33.0

REPAIR COUPLING (Sleeve)

L
(Molded fitting Shown)

SIZE
4
6
8
10
12
15

PART No.
558-040
558-060
558-080
558-010
558-012
558-015

STYLE
Fab
Fab
Fab
Fab
Fab
Fab

A
5.2
7.4
9.6
12.3
14.5
17.5

L
4.3
6.0
7.0
6.3
6.8
7.3

WT. (appox.)
0.7
1.6
3.4
6.2
9.2
15.9

PERMANENT PLUG

(Molded fitting Shown)

SIZE

PART No.

STYLE

WT. (appox.)

4
6
8
10
12
15

509-040
509-060
509-080
509-100
509-120
509-150

Molded
Molded
Molded
Fab
Fab
Fab

8.5
6.7
8.3
12.5
13.5
14.5

1.1
2.0
5.3
9.0
14.0
22.0

INCREASER GxS

A
B

(Molded fitting Shown)

SIZE
4
6
8
10
12
15

PART No.
544-040
544-060
544-080
544-100
544-120
544-150

STYLE
Molded
Molded
Molded
Fab
Fab
Fab

A
4.5
6.7
8.9
11.1
13.2
16.2

B
2.8
3.7
4.3
6.0
7.0
9.0

WT. (approx.)
0.2
2.5
2.3
9.0
15.0
25.0

NOTES:
All lay lengths & weights are approximate and are subject to
change without notice.
Fabricated fitting configurations may vary.
CAUTION: Vertical risers are not recommended.
Vertical risers are subject to problems without special consideration
of soil/pipe interaction, dead & live loads, and installation procedures.

(Molded fitting Shown)

SIZE
4x6
4x8
4x10
4x12
4x15
6x8
6x10
6x12
6x15
8x10
8x12
8x15
10x12
10x15
12x15

PART No.
516-0406
516-0408
516-0410
516-0412
516-0415
516-0608
516-0610
516-0612
516-0615
516-0810
516-0812
516-0815
516-1012
516-1015
516-1215

STYLE
Molded
Fab
Fab
Fab
Fab
Fab
Fab
Fab
Fab
Fab
Fab
Fab
Fab
Fab
Fab

L
11.8
12.0
18.5
18.5
19.3
13.0
19.0
19.0
19.8
20.5
19.5
20.3
22.0
21.8
24.5

WT. (appox.)
3.0
2.7
11.0
16.0
26.0
2.6
12.0
16.0
26.0
12.0
18.0
28.0
18.0
29.0
31.0

CALL FOR OTHER SIZES, CONFIGURATIONS & GASKET MATERIALS.

THE HARRINGTON CORPORATION


P.O. BOX 10335 LYNCHBURG VIRGINIA 24506 PLANT 3721 COHEN PLACE LYNCHBURG VIRGINIA 24501
PHONE: (434) 845-7094 FAX: (434) 845-8562 E-MAIL: sales@harcofittings.com
Form 135 5/21/10

HARCO SDR-26 PVC GASKETED SEWER FITTINGS


DESIGN DATA
90 Bend GxS

90 Bend GxG

(Molded fitting Shown)

(Molded fitting Shown)

SIZE

PART No.

STYLE

WT. (approx.)

4
6
8
10
12
15

518-040
518-060
518-080
518-100
518-120
518-150

Fab
Molded
Molded
Fab
Fab
Fab

6.5
3.7
8.0
9.0
11.5
12.5

3.5
4.2
12.0
21.0
40.0
73.0

SIZE
4
6
8
10
12
15

PART No.
519-040
519-060
519-080
519-100
519-120
519-150

45 Bend GxG

STYLE
Fab
Molded
Molded
Fab
Fab

L
6.5
3.7
8.0
9.0
11.5

Fab

12.5

WT. (approx.)
3.0
3.6
12.0
19.0
38.0
66.0

45 Bend GxS

(Molded fitting Shown)

SIZE
4
6
8
10
12
15

PART No.
522-040
522-060
522-080
522-100
522-120
522-150

STYLE
Molded
Molded
Molded
Fab
Fab
Fab

L
1.2
1.6
3.0
3.3
5.5
5.5

WT. (approx.)
1.5
2.8
8.0
16.0
30.0
48.0

(Molded fitting Shown)

SIZE
4
6
8
10
12
15

PART No.
523-040
523-060
523-080
523-100
523-120
523-150

22.5 Bend GxG

STYLE
Molded
Molded
Molded
Fab
Fab
Fab

L
1.2
1.6
3.0
3.3
5.5
5.5

WT. (approx.)
1.1
2.9
8.0
15.0
28.0
48.0

22.5 Bend GxS

L
(Molded fitting Shown)

SIZE
4
6
8
10
12
15

PART No.
524-040
524-060
524-080
524-100
524-120
524-150

STYLE
Molded
Molded
Fab
Fab
Fab
Fab

L
0.8
1.2
1.0
2.0
2.5
4.8

WT. (approx.)
1.3
3.2
8.0
16.0
25.0
51.0

NOTES:
All lay lengths & weights are approximate and are subject to
change without notice.
Fabricated fitting configurations may vary.

(Molded fitting Shown)

SIZE
4
6
8
10
12
15

PART No.
525-040
525-060
525-080
525-100
525-120
525-150

STYLE
Molded
Molded
Fab
Fab
Fab
Fab

L
0.8
1.2
1.0
2.0
2.5
4.8

WT. (approx.)
1.0
2.7
8.0
15.0
30.0
33.0

CALL FOR OTHER SIZES, CONFIGURATIONS & GASKET MATERIALS.

CAUTION: Vertical risers are not recommended.


Vertical risers are subject to problems without special consideration
of soil/pipe interaction, dead & live loads, and installation procedures.

THE HARRINGTON CORPORATION


P.O. BOX 10335 LYNCHBURG VIRGINIA 24506 PLANT 3721 COHEN PLACE LYNCHBURG VIRGINIA 24501
PHONE: (434) 845-7094 FAX: (434) 845-8562 E-MAIL: sales@harcofittings.com
Form 136 6/10/03

HARCO SDR-26 PVC GASKETED SEWER FITTINGS


DESIGN DATA
45 WYE GxGxG

C
(Molded fitting Shown)

SIZE
4X4
6X4
6X6
8X4
8X6
8X8
10X4
10X6
10X8
10X10
12X4
12X6
12X8
12X10
12X12
15X4
15X6
15X8
15X10
15X12
15X15

PART No.
501-0404
501-0604
501-0606
501-0804
501-0806
501-0808
501-1004
501-1006
501-1008
501-1010
501-1204
501-1206
501-1208
501-1210
501-1212
501-1504
501-1506
501-1508
501-1510
501-1512
501-1515

STYLE
Molded
Molded
Molded
Molded
Molded
Fab
Molded
Molded
Fab
Fab
Molded
Molded
Fab
Fab
Fab
Fab
Fab
Fab
Fab
Fab
Fab

C
5.1
7.1
7.6
8.0
9.3
18.9
17.0
18.3
20.3
22.5
18.3
19.6
21.6
22.8
25.6
20.2
21.5
23.5
25.7
27.5
30.2

L
11.8
16.0
16.0
15.0
18.5
29.5
26.0
29.0
31.5
35.5
27.0
30.0
32.5
36.5
39.5
29.0
32.0
34.5
38.5
41.5
46.0

WT. (approx.)
2.5
4.9
7.0
10.3
11.4
18.0
19.0
21.0
26.0
33.0
27.0
31.0
30.0
45.0
58.0
42.0
45.0
53.0
64.0
76.0
88.0

CALL FOR OTHER SIZES, CONFIGURATIONS & GASKET MATERIALS.

NOTES:
All lay lengths & weights are approximate and are subject to
change without notice.
Fabricated fitting configurations may vary.
CAUTION: Vertical risers are not recommended.
Vertical risers are subject to problems without special consideration
of soil/pipe interaction, dead & live loads, and installation procedures.

THE HARRINGTON CORPORATION


P.O. BOX 10335 LYNCHBURG VIRGINIA 24506 PLANT 3721 COHEN PLACE LYNCHBURG VIRGINIA 24501
PHONE: (434) 845-7094 FAX: (434) 845-8562 E-MAIL: sales@harcofittings.com
Form 137 6/10/03