P PI PG PCV PT PIT PIC PDT PRV PSV PS PSH PSL PSHH PSLL PDS PDSH PDSL PA
: : : : : : : : : : : : : : : : : : :
PRESSURE PRESSURE PRESSURE PRESSURE PRESSURE PRESSURE PRESSURE PRESSURE PRESSURE PRESSURE PRESSURE PRESSURE PRESSURE PRESSURE PRESSURE PRESSURE PRESSURE PRESSURE PRESSURE
INDICATOR GAUGE CONTROL VALVE TRANSMITTER INDICATING TRANSMITTER INDICATING CONTROLLER DIFFERENTIAL TRANSMITTER REDUCING VALVE SAFETY VALVE SWITCH SWITCH HIGH SWITCH LOW SWITCH HIGH HIGH SWITCH LOW LOW DIFFERENTIAL SWITCH DIFFERENTIAL SWITCH HIGH DIFFERENTIAL SWITCH LOW ALARM
TEMPERATURE
: : : : : : : : : : : : : : :
TEMPERATURE TEMPERATURE INDICATOR THERMOWELL THERMOMETER TEMPERATURE ELEMENT RESISTANCE TEMPERATURE DETECTOR THERMOCOUPLE TEMPERATURE TRANSMITTER TEMPERATURE INDICATING CONTROLLER TEMPERATURE RECORDER CONTROLLER TEMPERATURE CONTROL VALVE TEMPERATURE SWITCH TEMPERATURE SWITCH HIGH TEMPERATURE SWITCH LOW TEMPERATURE ALARM
FLOW
: : : : : : : : : : : :
FLOW FLOW FLOW FLOW FLOW FLOW FLOW FLOW FLOW FLOW FLOW FLOW
INDICATOR GLASS / FLOW GAUGE ELEMENT INDICATING TRANSMITTER CONTROL VALVE INDICATING CONTROLLER SWITCH CONVERTER ALARM RECORDER RECORDING CONTROLLER
Page 1 of 14
LEVEL
CHEMIN-IIM (XVI E)
: : : : : : : : : : : : :
LEVEL LEVEL INDICATOR LEVEL GAUGE LEVEL INDICATING TRANSMITTER LEVEL CONTROL VALVE LEVEL DISPLACER TRANSMITTER LEVEL INDICATING CONTROLLER LEVEL RECORDING CONTROLLER LEVEL SWITCH LEVEL SWITCH HIGH LEVEL SWITCH LOW LEVEL ALARM RADAR LEVEL TRANSMITTER
GENERAL
DCS : SCADA : PLC : HART : HHT : SFC : ESD : AOV : MOV : SV : XVE : XVT : AE : JB : ILD : P&ID : IIS : TDR : SP : NC : NO : MCC : IAS : IGS : ACFO : AOFC : FFA : P/I P to I : I/P I to P : PB : PID : E/H : BOV : A/M : ZS : HS :
DISTRIBUTED CONTROL SYSTEM SUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM PROGRAMMABLE LOGIC CONTROLLER HIGHWAY ADDRESSABLE REMOTE TRANSDUCER HAND HELD TERMINAL SMART FIELD CONFIGURATOR EMERGENCY SHUT DOWN AIR OPERATED VALVE MOTOR OPERATED VALVE SOLENOID VALVE VIBRATION PROXIMITOR VIBRATION TRANSMITTER ANALYZER JUNCTION BOX INSTRUMENT LOOP DIAGRAM PIPING AND INSTRUMENT DIAGRAM INSTRUMENT INSTALLATION SCHEDULE TIME DELAY RELAY SET POINT NORMALLY CLOSED NORMALLY OPEN MOTOR CONTROL CENTRE INSTRUMENT AIR SUPPLY INSTRUMENT GAS SUPPLY AIR TO CLOSE FAIL OPEN AIR TO OPEN FAIL CLOSE FLAME FAILURE ALARM PNEUMATIC TO CURRENT CONVERTER CURRENT TO PNEUMATIC CONVERTER PUSH BUTTON PROPORTIONAL, INTEGRAL AND DERIVATIVE ELECTRO HYDRAULIC ACTUATOR BLOW DOWN VALVE AUTO / MANUAL 2 POSITION SWITCH POSITION SWITCH HAND SWITCH
Page 2 of 14
2.3) ELECTRICAL SIGNAL (ANALOG SIGNAL) (mA DC (OR) VDC) -----------------------3.4) ELECTROMAGNETIC or SONIC SIGNAL 3.5) HYDRAULIC SIGNAL 2.6) CAPILLARY TUBE (FILLED SYSTEM) ___________________ ___________________ ___________________
2.7) PULSE TRAIN 2.8) INTERNAL SYSTEM LINK (SOFTWARE or DATA LINK)
_ _ _ _ _ _ _
-----------------------------------------------------------------------------------------------------------------
3) TYPES OF SUPPLY
3.1) 3.2) 3.3) 3.4) 3.5) 3.6) 3.7) AS ES GS HS NS SS WS AIR SUPPLY ELECTRICAL SUPPLY GAS SUPPLY HYDRAULIC SUPPLY NITROGEN SUPPLY STEAM SUPPLY WATER SUPPLY IA PA INSTRUMENT AIR PLANT AIR
Options
The ES or AS symbol is to be used only for Field Devices requiring supply. For panel mounted instruments power supplies are not shown on flow sheet.
ES 24 V DC
Page 3 of 14
Page 4 of 14
CHEMIN-IIM (XVI E)
Page 5 of 14
OUTPUT FUNCTION
MODIFIER
A B C D E F G H I J K L M N O P Q R S T U V
ANALYSIS (5, 19) BURNER, COMBUSTION USERS CHOICE (1) USERS CHOICE (1) VOLTAGE FLOW RATE USERS CHOICE (1) HAND CURRENT (ELECTRICAL) POWER TIME, TIME SCHEDULE LEVEL USERS CHOICE (1) MOMENTARY (4) SCAN (7) TIME, RATE OF CHANGE (4, 21) RATIO (FRACTION) (4) DIFFERENTIAL (4)
CONTROL STATION (22) LIGHT (11) LOW (7, 15, 16) MIDDLE, INTERMEDIATE (7, 15) USERS CHOICE (1) ORIFICE, RESTRICTION POINT (TEST) CONNECTION USERS CHOICE (1) USERS CHOICE (1)
USERS CHOICE (1) USERS CHOICE (1) PRESSURE, VACUUM QUANTITY RADIATION SPEED, FREQUENCY TEMPERATURE MULTIVARIABLE (6) VIBRATION, MECHANICAL ANALYSIS (19) SAFETY (8) INTEGRATE, TOTALIZE (4)
VALVE, DAMPER, LOUVER (13) WELL X AXIS Y AXIS Z AXIS UNCLASSIFIED (2) UNCLASSIFIED (2) RELAY, COMPUTE, CONVERT(13,14,18) DRIVER, ACTUATOR, UNCLASSIFIED FINAL CONTROL ELEMENT UNCLASSIFIED (2)
W WEIGHT, FORCE X Y Z
UNCLASSIFIED (2) EVENT, STATE / PRESENCE (20) POSITION, DIMENSION
Page 6 of 14
Page 7 of 14
TABLE -3
Page 8 of 14
CHEMIN-IIM (XVI E)
Page 9 of 14
CHEMIN-IIM (XVI E)
Page 10 of 14
CHEMIN-IIM (XVI E)
Page 11 of 14
CHEMIN-IIM (XVI E)
Page 12 of 14
CHEMIN-IIM (XVI E)
Page 13 of 14
CHEMIN-IIM (XVI E)
8. APPLICATION EXERCISE
Page 14 of 14