COIL CHARACTERISTICS
CODE Nominal voltage Maximum voltage Maximum pickup voltage Dropout voltage Inrush current Hold current Suppressor circuit R 28 Vdc 32 Vdc 18 Vdc 2 Vdc min. 8 Vdc max. 4 A max. @ 28 Vcc 150 mA at 28 Vcc 65 Vpeak 42 Vpeak R
Series CC02**P
GENERAL CHARACTERISTICS
Temperature range Life at nominal load Dielectric strength at sea level Dielectric strength at altitude 25,000 m Insulation resistance at 500 Vdc Sinusoidal vibrations Shock Maximum contact opening time under vibration and shock Maximum operate time at 28 Vdc Maximum dropout time at 28 Vdc Power contact voltage drop - initial value - After life -55C to +85C 50,000 cycles 1250 Vrms 500 Vrms 100 M 10G / 5 to 2000 Hz 30G / 11 ms 10 s 20 ms 15 ms max 120 mV 180 mV
Auxiliary contacts - Voltage drop at 1 Amp - Contact resistance at low level (<20 mA) - Minimum current Mounting torque - Power terminal
70 mV max 1 2 mA
M8 M5
9 Nm 2.45 Nm
- 156 -
Page 2 of 4
CONFIGURATION STYLES
25.5 ACCORDING TO CONNECTION MODE 30.75 19.45 17.75
Series CC02**P
MOUNTING STYLES
3M2
71.5
39.8
12.5
17
DIA
STYLE A - 8.5 DIA HOLE 17.75 35.5 = 20 = DIMENSION A 19.45 DIMENSION B 8 STYLE B - 5 DIA HOLE
MOUNTING DIMENSIONS
TYPE TYPE TYPE TYPE TYPE 1 2 3 4 5 40 35 33.5 30 40 31 43 30 48 38
16 THREADING STYLE C - M5 CAPTIVE SCREWS STYLE D - UNF 10/32 CAPTIVE SCREWS
A 35.5 35.5 40
30.75
CONNECTOR
170
24.25
LOCATING KEYS
1 9 4 3
8 7
LOCATING KEYS
35.5
35.5
27.1
25.75
TYPE 1
TYPE 2
TYPES 3 - 4 -5
- 157 -
Page 3 of 4
SCHEMATIC DIAGRAM
8
T2
Series CC02**P
9
R2
2
T1
3
R1
8
T2
9
R2
2
T1
3
R1
C2
C1
C2
C1
7 6
SEE NOTE 2
+
1
7 6
SCHEMATIC 1
NOTE 2: AVAILABLE WITHOUT SUPPRESSOR.
SCHEMATIC 2
+
1
NUMBERING SYSTEM
P/N CC0202P-XXR699 CC0201P-XXR62A CC0238P-XXN78A CC0201P-XXR02B CC0201P-XXN97A MOUNTING MOUNTING CONNECTOR SCHEMATIC STYLE SIZE TYPE CODE A A C A A 3 4 1 1 2 1 1 1 2 1 1 2 3 3 3 CONNECTOR TYPE Berg P/N 65239-005 Berg P/N 66987-05 SubD 9 contacts M 24 308/24-1F SubD 9 contacts M 24 308/24-1F SubD 9 contacts M 24 308/24-1F
MOUNTING ACCESSORIES
A 0.1 F 0.1 C
0.1
8 M
BRASS TERMINAL
1.50.1 B 0.1
INSULATION BODY
MALE TERMINAL
A 0.1
0.1
TERMINAL/CHASIS MOUNTING
120 3 PLACES
TERMINAL P/N TYPE 50AB41-00 MALE 72VB41-04 MALE 72VB41-03 MALE 72VB41-02 MALE 72VB41-01 FEMALE
DIMENSIONS C D E 22 DIA 5 DIA M8 20 DIA 4 DIA M8 20 DIA 4 DIA 5/16" UNF2A 20 DIA 4 DIA M6 M5
F 22 22 22 15 7.5
FEMALE TERMINAL
STANDARD TOLERANCE: .XX .5mm
17 20 DIA 4 DIA
- 158 -
Page 4 of 4