Energy Efficient
Fan & Pump Control
0.75kW 250kW / 1HP 350HP 200 480V Single & 3 Phase Input
www.invertek.co.uk
IP 66
IP20 0 12 IP4 MA NE 4X 5/ A 5 IP EM N /
Service Indicator
OPTIFLOW
Plug-in Modules
(Page 9)
Cumulative Savings
Save Energy
y y Highly efficient operation Automatic optimisation when load decreases In-built sleep mode prevents lost energy when flow is low or zero
Noise Reduction
Quiet Motor Operation
High switching frequency selection (up to 32kHz) ensures motor noise is minimised.
Allows manual control (of fan or pump) to easily be selected in the event of an automatic control system failure or for simplified commissioning / system checks, or when a fast temporary override of the control system is required. Built-in Auto Control Selection allows return to automatic system control just as easily.
Save Money
y y Advanced features as standard Options for additional flexibility
Save Time
y y y y Simple parameter set allows fast installation and commissioning OptiTools Studio & Optistick make programming a breeze Customisable OLED Display Pluggable terminals
RoHS
www.invertek.co.uk
3
Stairwell Pressurisation
In the event of a fire, stairwells are often essential escape routes.
Optidrive HVAC can be used to control air flow and pressure to help keep stairwells clear of smoke to allow safe evacuation and give firefighters safe access to buildings.
Flow (%)
Intelligent Standby
To reduce energy used by slow-running fans, Optidrive HVAC has an intelligent standby/sleep function to shut off output from the drive until demand for air flow increases.
Resonance Avoidance
Optidrive HVAC can be easily configured to avoid frequencies that cause resonance in ventilation systems, preventing unnecessary noise and mechanical damage to motors and fans.
Using Optidrive HVAC compared to direct on-line control, an estimated 20% reduction in speed results in potential energy savings of 50%.
Calculation based on a typical estimated factory working week and energy costs, including estimated component and installation costs.
www.invertek.co.uk
5
Co-ordinated pump station control, built into each Optidrive HVAC as standard, allows independent control of multiple pump applications.
Setpoint Control
y y y
All drives operate as variable speed for maximum energy saving. Equal run time sharing across every pump. Automatic system reconfiguration in the event of a pump fault (including the master pump). Continued system operation when drives are individually powered off (including the master drive). Communication and +24V control voltage shared between drives via a standard RJ45 patch lead. Independent maintenance indicators for each pump. Any pump can be switched to Hand operation a the touch of a button, and will automatically rejoin the network when switched back to Auto. For waste water applications each pump can be set for blockage/ragging detection and activate an automatic de-ragging/pump cleaning cycle. Optional mains isolator with lock-off for safe pump maintenance. Optiflow function configured through simple parameter set-up and intelligent drive self configuration. OptiFlow Communications Independent pump system control
y y
Feedback signal
y y
Pump Efficiency
In-built Sleep Mode with Auto-boost
Sleep mode saves energy by detecting when a pump is running inefficiently and producing little useful work. Optidrive HVAC can be programmed to enter into a sleep/disabled mode until the demand increases. To help prevent sleep mode oscillation, Optidrive HVAC can automatically initiate a boost cycle to increase pressure on starting or stopping.
Relay 1 Output Relay 2 Output Relay 3 Output Relay 4 Output Sensor feedback to drive PID Master Pump Slave Pump 1 Slave Pump 2 Slave Pump 3 Slave Pump 4
Sensor
Enclosure Options
OLED Display
IP20
Sizes 2 & 3
IP40
Size 8 only
IP55/NEMA 12
Sizes 47 Protected against dust and jets of water.
IP66/NEMA 4X
Sizes 2 & 3 Dust-tight and protected against high-pressure water jets. Available with or without isolator switch.
Flexible,
8
Powerful PC Software
Drive commissioning and parameter backup
y y y y Real-time parameter editing Drive network communication Parameter upload, download and storage Simple PLC function programming
Plug-in Modules
OPTIPAD
OPTISTICK
Fieldbus Interfaces
BACnet/IP, Profibus DP, DeviceNet and EtherNet/IP
www.invertek.co.uk
9
ct R
de
du
de
Mo
Mo
ne
du
ct R
ne
kW
0.75 1.5 2.2 0.75 1.5 2.2 4 5.5 5.5 7.5 11 15 18.5 22 30 37 45 55 75 0.75 1.5 2.2 4 5.5 7.5 11 11 15 18.5 22 30 37 45 55 75 90 110 132 160 200 250
1 2 3 1 2 3 5 7.5 7.5 10 15 20 25 30 40 50 60 75 100 1 2 3 5 7.5 10 15 15 20 25 30 40 50 60 75 120 150 175 200 250 300 350
4.3 7 10.5 4.3 7 10.5 18 24 24 30 46 61 72 90 110 150 180 202 248 2.2 4.1 5.8 9.5 14 18 24 24 30 39 46 61 72 90 110 150 180 202 240 302 370 450
2 2 2 2 2 2 3 3 4 4 4 5 5 6 6 6 6 7 7 2 2 2 2 3 3 3 4 4 4 4 5 5 5 6 6 6 6 7 7 8 8
ODV - 2 - 2 2 075 - 1 K F 1 # - # # ODV - 2 - 2 2 150 - 1 K F 1 # - # # ODV - 2 - 2 2 220 - 1 K F 1 # - # # ODV - 2 - 2 ODV - 2 - 2 ODV - 2 - 2 ODV - 2 - 3 ODV - 2 - 3 ODV - 2 - 4 ODV - 2 - 4 ODV - 2 - 4 ODV - 2 - 5 ODV - 2 - 5 ODV - 2 - 6 ODV - 2 - 6 ODV - 2 - 6 ODV - 2 - 6 ODV - 2 - 7 ODV - 2 - 7 ODV - 2 - 2 ODV - 2 - 2 ODV - 2 - 2 ODV - 2 - 2 ODV - 2 - 3 ODV - 2 - 3 ODV - 2 - 3 ODV - 2 - 4 ODV - 2 - 4 ODV - 2 - 4 ODV - 2 - 4 ODV - 2 - 5 ODV - 2 - 5 ODV - 2 - 5 ODV - 2 - 6 ODV - 2 - 6 ODV - 2 - 6 ODV - 2 - 6 ODV - 2 - 7 ODV - 2 - 7 ODV - 2 - 8 ODV - 2 - 8 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 075 - 3 150 - 3 220 - 3 040 - 3 055 - 3 055 - 3 075 - 3 110 - 3 150 - 3 185 - 3 022 - 3 030 - 3 037 - 3 045 - 3 055 - 3 075 - 3 075 - 3 150 - 3 220 - 3 400 - 3 055 - 3 075 - 3 110 - 3 110 3 150 - 3 185 - 3 220 - 3 300 - 3 370 - 3 450 - 3 055 - 3 075 - 3 090 - 3 110 - 3 132 - 3 160 - 3 200 - 3 250 - 3 K K K K K K K K K K K K K K K K K K K K K K K K K K K K K K K K K K K K K K F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F 1 #-## 1 #-## 1 #-## 1 #-## 1 2 -## 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 #-## 1 #-## 1 #-## 1 #-## 1 #-## 1 #-## 1 2 -## 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 4 -T# 1 4 -T#
HP
kW
HP Amps Size
Pr o
Ge
Pr o
ODV - 2 - 2 2 010 - 1 H F 1 # - # # ODV - 2 - 2 2 020 - 1 H F 1 # - # # ODV - 2 - 2 2 030 - 1 H F 1 # - # # ODV - 2 - 2 ODV - 2 - 2 ODV - 2 - 2 ODV - 2 - 3 ODV - 2 - 3 ODV - 2 - 4 ODV - 2 - 4 ODV - 2 - 4 ODV - 2 - 5 ODV - 2 - 5 ODV - 2 - 6 ODV - 2 - 6 ODV - 2 - 6 ODV - 2 - 6 ODV - 2 - 7 ODV - 2 - 7 ODV - 2 - 2 ODV - 2 - 2 ODV - 2 - 2 ODV - 2 - 2 ODV - 2 - 3 ODV - 2 - 3 ODV - 2 - 3 ODV - 2 - 4 ODV - 2 - 4 ODV - 2 - 4 ODV - 2 - 4 ODV - 2 - 5 ODV - 2 - 5 ODV - 2 - 5 ODV - 2 - 6 ODV - 2 - 6 ODV - 2 - 6 ODV - 2 - 6 ODV - 2 - 7 ODV - 2 - 7 ODV - 2 - 8 ODV - 2 - 8 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 010 - 3 H 020 - 3 H 030 - 3 H 050 - 3 H 075 - 3 H 075 - 3 H 100 - 3 H 150 - 3 H 020 - 3 H 025 - 3 H 030 - 3 H 040 - 3 H 050 - 3 H 060 - 3 H 075 - 3 H 100 - 3 H 010 - 3 H 020 - 3 H 030 - 3 H 050 - 3 H 075 - 3 H 100 - 3 H 150 - 3 H 150 - 3 H 200 - 3 H 250 - 3 H 300 - 3 H 040 - 3 H 050 - 3 H 060 - 3 H 075 - 3 H 120 - 3 H 150 - 3 H 175 - 3 H 200 - 3 H 250 - 3 H 300 - 3 H 350 - 3 H F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F 1 #-## 1 #-## 1 #-## 1 #-## 1 2 -## 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 #-## 1 #-## 1 #-## 1 #-## 1 #-## 1 #-## 1 2 -## 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 N- T # 1 4 -T# 1 4 -T#
kW Models: Factory Settings Motor Rated Frequency: 50Hz Motor Rated Voltage: 400V
HP Models: Factory Settings Motor Rated Frequency: 60Hz Motor Rated Voltage: 460V
Ge
Replace # in model code with colour-coded option IP20 units are available with 7 Segment LED Display only
St a B C o nd a Fu l a r d C t i n g lC on oatin fo r ma g lC o
ns
ns
od
od
a ng
lC
lC
a ng
clo
En
atin
NOT TO SCALE
Size
Enclosure Height (mm) Width (mm) Depth (mm) Weight (kg)
2
IP20 221 112 185 1.8
2
IP66 257 188 239.5 4.8
3
IP20 261 131 205 3.5
3
IP66 310 211 251.5 7.3
4
IP55 440 173 230 11.5
5
IP55 540 235 270 22.5
6
IP55 865 330 340 50
7
IP55 1280 330 370 80
8
IP40 2000 516 500 270 W D
10
Drive Specification
Input Ratings
Supply Voltage Supply Frequency Displacement Power Factor Phase Imbalance Inrush Current Power Cycles 200 240V 10% 380 480V 10% 48 62Hz > 0.98 3% Maximum allowed < rated current 120 per hour maximum, evenly spaced 230V 1 Phase Input: 0.752.2kW (13HP) 230V 3 Phase Input: 0.7575kW (1100HP) 400V 3 Phase Input: 0.75250kW 460V 3 Phase Input: 1350HP 110% for 60 seconds 0 120Hz, 0.1Hz resolution 98% Storage : 40 to 60C Operating : 10 to 40C Up to 1000m ASL without derating Up to 2000m maximum UL approved Up to 4000m maximum (non UL) Above 1000m : Derate by 1% per 100m 95% Max, non-condensing IP20 (Frame sizes 2 & 3) IP66 (Frame sizes 2 & 3; up to 7.5kW) IP55 (Frame sizes 4 7) IP40 (Frame size 8) Built-in keypad as standard Optional remote mountable keypad Built-in multi language OLED display (except IP20) LED display (IP20 only) OptiTools Studio Digital Inputs Setpoint Control Digital Analog Signal
Control Specification
Variable Torque V/F Variable Torque Energy Optimised V/F 4 32kHz Effective Ramp to Stop : User Adjustable 1 600 seconds Coast to Stop Motor Flux Braking Single point, user adjustable 0 to 10 Volts 10 to 0 Volts 10 to +10 Volts 0 to 20mA 20 to 0mA 4 to 20mA 20 to 4 mA Motorised Potentiometer (Keypad) Modbus RTU BACnet BACnet/IP, Profibus DP, DeviceNet, EtherNet/IP
Control Features
Selectable direction Selectable speed reference Under load monitoring with autotune configuration Internal PID control with feedback display Pump load monitoring with autotune function, user configurable Adjustable Pump Cleaning Cycle operation Control of fixed speed assist pumps via optional cascade control module Control of Duty, Assist and Standby variable speed pumps via internal Master Slave network Automatic pump stir function Last 4 Trips stored with time stamp Logging of data prior to trip for diagnostic purposes : Output Current, Drive Temperature, DC Bus Voltage Maintenance Indicator with user adjustable maintenance interval Onboard service life monitoring Hours Run Meter Resettable & Non Resettable kWh meters Adjustable speed electrical power drive systems. EMC requirements.
Output Ratings
Output Power Overload Capacity Output Frequency Typical Efficiency
Optional
Ambient Conditions
Temperature
I/O Specification
Power Supply
24 Volt DC, 100mA, Short Circuit Protected 10 Volt DC, 5mA for Potentiometer 5 Total as standard (Optional additional 3)
Altitude Humidity
Programmable Inputs
3 Digital (Optional additional 3) 2 Analog / Digital Selectable 10 30 Volt DC, internal or external supply, NPN Response time : < 4ms Resolution : 12 bits Response time : < 4ms Accuracy : < 1% full scale Parameter adjustable scaling and offset 4 Total (Optional additional 3) 2 Analog / Digital 2 Relays (Optional additional 3) Maximum Voltage : 250 VAC, 30 VDC Switching Current Capacity : 6A AC, 5A DC
Standards Compliance
EN 618003:2004
Enclosure
Ingress Protection
Programming
Analog Inputs
Keypad Display PC
Connection Diagram
Function
Digital Input 1 Digital Input 2 Digital Input 3
ODV-2-22075-1KF1#-##
Product Family Generation Frame Size 200-240V = 2 380-480V = 4 Supply Voltage
Default Setting
Drive Enable Analog / Preset Speed 1 Select Local / Remote Reference Select
Analog Output 1 0 Volt Analog Input 2 Analog Output 2 Safe Torque Off Input Safe Torque Off Input
Motor Speed
No Brake Transistor = 1
Output Relay 1
Display PCB Coating
www.invertek.co.uk
Output Relay 2 Drive Running
11