Introduction

Tyco MX Technology brings together the latest fire detection technology from around the world into a comprehensive international range of fire detection systems. Tyco MX Technology can be used to provide cost effective solutions on small fire detection systems whilst also providing the features and functions required on very large commercial and industrial sites. Tyco MX Technology is being made available on a wide range of internationally approved panels and systems available from Tyco companies world-wide including: . . . . MINERVA MX PANELS MINERVA MARINE T2000 PANELS ZETTLER EXPERT PANELS MINERVA SOLO PANELS

Features:
. . . MX VIRTUAL multi-sensor detectors MX DIGITAL robust & reliable high speed loop protocol Rapid response to fire conditions and very low false alarms through: . MX FASTLOGIC detection algorithms . MX HPO detection algorithms . MX CCO fire detection

Page 1

Table of Contents
3 MX Panels 10 MX Panel Components 15 MX Panel User Interface Modules 19 MX Graph/ MX Net 21 Minerva Solo Detection Panels 22 Batteries 23 MX Virtual Multi-Sensor Detectors 26 Detector Mode Selection & Design Charts 28 Standard Universal Bases 29 Functional Detector Bases 30 Detector Ancillaries 34 Detector Housings 35 MX Ancillary 38 MX Addressable Input/Output Modules 42 MX Ancillary Housing 44 Programming & Service Tools 45 Sales Tools 46 Approvals 47 Standard Auto CAD Symbols

tyco
Page 2

48 Product Code Index

MX Panels
MX Detection Panels

Tyco MX detection panels use all the features of Tyco MX Technology to provide the latest fire detection technology meeting the latest worldwide standards in costeffective, expandable packages.

Tyco MX detection panels include:


. . . MINERVA MX for EN54 LPCB approved systems ZETTLER EXPERT for EN54 LPCB & VdS approved systems MINERVA EXPERT T2000 for Marine approved systems . . . Viewing and printing status Viewing and printing isolated points Manual and automatic walk test and reporting functions Viewing and printing maintenance reports Extensive diagnostic functions including simulation and force outputs Text and configuration changes Automatic battery test Detector service functions

Tyco MX detection panels support Tyco MX Technology:


. . . . MX VIRTUAL Multi-sensor detectors MX DIGITAL high speed reliable digital protocol MX FASTLOGIC fuzzy logic smoke detection algorithms MX CCO universal carbon monoxide fire detection algorithms

. .

Other variants available soon will carry UL, ULC, FM, SSL and other European listings and approvals.

Tyco MX detection panels include a powerful user interface:


. . . 640 Character display

. . .

Tyco MX detection panels provide modular cost effective solutions:


. Networked panels from 1 to 396 detection loops Powerful central loop processing functions Powerful and modular user interface MX REMOTE diagnostics and service functions MX GRAPH graphical user interfaces Designer and modular housing options

Displays first alarm and most recent alarm Permanently displays systems status including number of alarms, number of faults, number of isolated points Scroll function allows details of all events and status to be easily viewed Displays temperature, CO level and smoke level at point in alarm Displays 95 character custom messages for emergency procedures

Tyco MX detection panels include very powerful event/action programming including:


. . . . Seamless network wide event/action 240 x 240 Output map and output sequencing algorithms Over 1500 event/action groups for the most complex applications Templates for fast programming of standard applications including: - EN54/BS5839 - EN54/VdS - EN54 Marine User defined templates Time, date and special day programming Wide range of co-incidence, double knock and delay functions

. . .

. . .

. .

Tyco MX panels include advanced manager and engineer functions including:


. . . . . Menu driven Multi-level password protected Viewing 1000 event log Detailed fault reporting Isolate by point, zone or sector . . . Tyco MX detection panels provide long term fire detection solutions including upgrade paths from earlier panel models and a long term development strategy providing future upgrade paths.

Page 3

MINERVA MX1000 & MX4000


incorporates the ODM800 operator display module with a 16 x 40-character backlit LCD display, simple alphanumeric keypad, 5 softkeys and a fast access key. The OCM800 operator control module provides all mandatory operator control keys and LED functions including Day/Night switching. Two control keys and 2 indication LEDs are provided for site-specific functions. Control keys and LEDs are labelled in English according to the default LPCB functionality. The slide in decals can be reversed and alternative text added. Product Codes Standard Panels 557.200.001 MX1000 Single Loop Panel Shallow Back Box 557.200.020 MX1000 Single Loop Panel- Shallow Back Box DANISH 557.200.021 MX1000 Single Loop Panel- Shallow Back Box DANISH/ENGLISH 557.200.002 MX1000 Single loop panel - Flush Back Box 557.200.003 MX4000 Two to Four Loop Panel Shallow Back Box 557.200.022 MX4000 Two to Four Loop Panel - Shallow Back Box - DANISH 557.200.023 MX4000 Two to Four Loop Panel - Shallow Back Box - DANISH/ENGLISH 557.200.004 MX4000 Two to Four Loop Panel Deep Back Box 557.200.009 MX4000 Two to Four Loop Panel - Flush Back Box Options 557.202.006 IOB-800 (8in/8out) expansion board (Max. 24 I/O on main panel) 557.202.007 XLM-MX two loop MX DIGITAL expansion card 557.202.026 TLI-800 ThornNet & MX-NET network card 557.202.036 Remote Diagnostic Modem 557.202.116 Modem Lead 557.202.118 MX CONSYS download lead

The MINERVA MX panels are intelligent LPCB EN54 approved* panels, which can be networked to provide up to 396 detection loops and installed to BS5839:Pt.1. . The MX1000 supports one MX DIGITAL detection loop with up to 250 addressable devices. . The MX4000 supports two MX DIGITAL detection loops and can be expanded to four loops supporting up to 1000 addressable devices. Both panels consist of a strong steel enclosure incorporating a removable chassis plate. The chassis plate holds: . PSB800 5A 24Vd.c. battery backed power supply and loop booster to EN54:pt.4 . FIM800 field interface PCB incorporating one or two MX DIGITAL loops . CPU800 32 bit processor and memory card . Optional network card, additional loop card (s) and remote diagnostic modem . Optional IOB800 input/output expansion card mounted on the PSB800 The panel has a strong cast aluminium front door, which incorporates a modular user interface that fully complies with EN54:pt.2. The user interface

Battery & Expansion Boxes

The batteries and any additional zone LEDs or operator controls and firemans interface are mounted in a separate housing which can be mounted below the main panel or behind the panel. The matching battery and expansion box is available with shallow (17Ah) or deep backbox (38Ah) according to the batteries used. The chassis plate in the battery box also has space for up to 2 x IOB800 input/output expansion modules (maximum 24 I/O) or 1 x MX FILNET or 1 x PSM/PSB800. Product Codes 557.200.005 MX-BBX 17Ah shallow expansion and battery box 557.200.019 MX-BBX-F 17 Ah shallow flush expansion and battery box 557.200.006 MX-DPBX 38Ah deep expansion and battery box Certain popular configurations are available with

the zone LED modules pre-fitted. Product Code 557.200.007 MX-BBX-40LED 17Ah battery box with 40 zone LEDs 557.200.008 MX-DPBBX-40LED 38Ah battery box with 40 Zone LEDS.

Where no additional controls are required the low cost MX-BATT battery box can be used for housing up to 38Ah batteries and IOB800 boards. Product Code 557.200.016 MX-BATT Deep battery box

Page 4

MINERVA MX Modular Panels


or two MX DIGITAL loops CPU800 32 bit processor and memory card Optional network card, additional loop card (s) and remote diagnostic modem The panel has a lockable architectural front door with lockable window, which incorporates a modular user interface that fully complies with EN54:pt.2. The user interface incorporates the ODM800 operator display module with a 16 x 40character backlit LCD display, simple alphanumeric keypad, 5 softkeys and a fast access key. The OCM800 operator control module provides all mandatory operator control keys and LED functions including Day/Night switching. Two control keys and 2 indication LEDs are provided for site-specific functions. . . Control keys and LEDs are labelled in English according to the default LPCB functionality. The slide in decals can be reversed and alternative text added. The panel incorporates sufficient space to accommodate 2 x 17Ah or 2 x 38Ah batteries and sufficient space in the front door to take 2 or 6 additional user interface modules including 80 way red LED module (ANN880) , 40 way red/yellow LED module or 20 way status/command firemans interface module. Product Codes Standard Panels 557.200.100 MX4000M Two to Four Loop Panel 3 Tier Deep housing 557.200.101 MX4000M Two to Four Loop Panel 5 Tier Deep housing Options 557.202.006 IOB-800 (8in/8out) expansion board (Max. 24 I/O on main panel) 557.202.007 XLM-MX two loop MX DIGITAL expansion card 557.202.026 TLI-800 ThornNet & MX-NET network card 557.202.036 Remote Diagnostic Modem 557.202.116 Modem Lead 557.202.118 MX CONSYS Download lead

The MINERVA MX Modular panels are intelligent LPCB EN54 approved panels, which can be networked to provide up to 396 detection loops and installed to BS5839:Pt.1. The MX4000M supports two Tyco MX DIGITAL detection loops and can be expanded to four loops supporting up to 1000 addressable devices. The modular panels are manufactured so they can be retrofitted into the TFX series of fire controllers, for upgrades. The construction of the modular units is not the standard 19 inch rack mounting system. The panel consists of a strong rack style steel enclosure which can be surface or semi-flush mounted. The main removable chassis plate holds: . PSB800 5A 24Vd.c. battery backed power supply and loop booster to EN54pt4 . FIM800 field interface PCB incorporating one

MINERVA MX Repeaters
The MINERVA MX repeater with Power Supply is connected to the Panel via the remote bus (RS485, 1200 m distance). A maximum of 2 repeaters (including one MX REMOTE repeater) can be linked to each MINERVA MX panel and can provide full repeater functions for all panels on the system. The operator control module (OCM800) can support up to 80 inputs and outputs in the form of LED annunciators, IOB800 input/output modules, XIOM universal I/O modules or XIOM 800 LED mimic module. Product Codes Standard Repeaters 557.200.012 MXR Repeater with shallow backbox 557.200.017 MXR-F Repeater with flush backbox 557.200.013 MXR-PSU Repeater and addressable PSU 557.200.018 MXR-PSU-F Repeater and addressable PSU with flush backbox Options 557.202.006 IOB-800 (8in/8out) expansion board 557.180.005 Mimic driver module 557.180.016 XIOM universal I/O module 557.202.028 RSM800 PSU Module 557.202.042 24VDC Repeater Cable Assembly

The MINERVA MX full function repeater is an EN54 LPCB approved repeater with optional addressable EN54:Pt.4 power supply. The repeater consists of a steel backbox and cast aluminium front door which incorporates the ODM800 operator display module with a 16 x 40character backlit LCD display, simple alphanumeric keypad, 5 softkeys and a fast access key. The OCM800 operator control module provides all mandatory operator control keys and LED functions including Day/Night switching. Two control keys and 2 indication LEDs are provided for site-specific functions. Control keys and LEDs are labelled in English according to the default LPCB functionality. The slide in decals can be reversed and alternative text added. The back box has a removable chassis plate with the PSM800 power supply, APM800 addressable PSU monitor and space for 2 x 7 Ah batteries to provide 72 h backup.

Page 5

MINERVA Expert T2000 Marine Detection Panel


The panel has a strong cast aluminium front door, which incorporates a modular user interface that fully complies with EN54 pt2. The user interface incorporates the ODM800 operator display module with a 16 x 40-character backlit LCD display, simple alphanumeric keypad, 5 softkeys and a fast access key. The OCM800 operator control module provides all mandatory operator control keys and LED functions including Day/Night switching. Two control keys and 2 indication LEDs are provided for vessel specific functions. Control keys and LEDs are labelled in English according to the default Marine functionality. The slide in decals can be reversed and alternative text added. The batteries and any additional zone LEDs or operator controls are mounted in a separate housing which can be mounted below the main panel or behind the panel. The battery box has a heavy duty backbox and battery clamp. The chassis plate in the battery box also has space for up to 2 x IOB800 input/output expansion modules (maximum 24 I/O) or 1 x PSM/PSB800. Product Codes 557.200.600 T2000 Two To Four Loop Marine Panel 557.200.602 T2000B Battery Box

The T2000 is a fully Marine approved EN54 compliant 1 to 4 loop networkable detection panel. The T2000 supports two Tyco MX DIGITAL detection loops and can be expanded to four loops supporting up to 1000 addressable devices. The T2000 consists of a strong steel Marine approved enclosure incorporating: . PSB800M 5A 24V DC battery backed power supply and loop booster to EN54pt4 . FIM800 field interface PCB incorporating one or two MX DIGITAL loops . CPU800 32 bit processor and memory card . Optional network card and additional loop card(s)

MINERVA Expert T2000 Marine Repeater


according to the default Marine functionality. The slide in decals can be reversed and alternative text added. The back box has a removable chassis plate with the PSM800M power supply, APM800 addressable PSU monitor and space for 2 x 7 Ah batteries to provide 72 h backup. The T2000 repeater with Power Supply is connected to the Panel via the remote bus (RS485, 1200 m distance). A maximum of x 2 repeaters (including one MX REMOTE repeater) can be linked to each T2000 panel and can provide full repeater functions for all panels on the system. The operator control module (OCM800) can support up to 80 inputs and outputs in the form of LED annunciators, IOB800 input/output modules, XIOM universal I/O modules or XIOM 800 LED mimic module. Product Codes 557.200.601 T2000R Marine Repeater with Power Supply Unit 557.200.604 T2000R Marine Repeater without Power Supply Unit

The T2000 full function repeater is an EN54 Marine approved repeater with optional addressable EN54:Pt.4 power supply. The repeater consists of a steel backbox and cast aluminium front door which incorporates the ODM800 operator display module with a 16 x 40character backlit LCD display, simple alphanumeric keypad, 5 softkeys and a fast access key. The OCM800 operator control module provides all mandatory operator control keys and LED functions including Day/Night switching. Two control keys and 2 indication LEDs are provided for vessel-specific functions. Control keys and LEDs are labelled in English

Page 6

ZETTLER Expert 1000 & 4000


The ZETTLER EXPERT panels are intelligent LPCB & VdS certified EN54 panels, which can be networked to provide up to 256 detection loops. Features . The ZX1 supports one Tyco MX DIGITAL detection loop with up to 250 addressable devices or 128 for VdS certified installations. . The ZX4 supports two Tyco MX DIGITAL detection loops and can be expanded to four loops supporting up to 1000 addressable devices or 512 devices for VdS certified installations. Both panels consist of a strong deep steel enclosure incorporating a removable chassis plate. The chassis plate holds: . PSB800 5A 24V DC battery backed power supply and loop booster to EN54:pt.4 . FIM800 field interface PCB incorporating one or two MX DIGITAL loops . CPU800 32 bit processor and memory card . Optional network card, additional loop card (s) and remote diagnostic modem The panel has a strong cast aluminium front door, which incorporates a modular user interface that fully complies with EN54:pt.2. The user interface incorporates the ODM800 operator display module with a 16 x 40-character backlit LCD display, simple alphanumeric keypad, 5 softkeys and a fast access key. The OCM800 operator control module provides all mandatory operator control keys and LED functions including Day/Night switching. Four control keys and 4 indication LEDs are provided for site-specific functions. Control keys and LEDs are labelled in German according to the default VdS functionality. The slide in decals can be reversed and alternative text added. The batteries and any additional zone LEDs or operator controls are mounted in a separate housing which can be mounted below the main panel or behind the panel. This expansion battery box is supplied with the panel as a deep box to take 38Ah batteries. The chassis plate in the battery box also has space for up to 2 x IOB800 input/output expansion modules (maximum 24 I/O) or a TUD800 German Fire Brigade transmission unit. The battery box can have one or two 40 way zone indicators (ANN840) mounted in the front door. Product Codes Standard Panels 542.080 ZX1 1 Loop Panel c/w Deep 38Ah Battery Box 542.081 ZX4 2 - 4 Loop Panel c/w Deep 38Ah Battery Box Options 542.006 IOB-800 (8in/8out) expansion board (Max. 24 I/O on main panel) 542.007 XLM-MX two loop MX DIGITAL expansion card 542.010 TUD-800 German Transmission Unit 542.025 MX-FIL FILNET network card 542.026 TLI800 MX-NET Network card 542.036 Remote Diagnostic Modem 542.008 Modem lead 542.011 MX CONSYSDownload lead

ZETTLER Expert Repeaters


The ZETTLER EXPERT full function repeater is an EN54 LPCB & VdS certified repeater with optional addressable EN54:Pt.4 power supply. The repeater consists of a steel backbox and cast aluminium front door which incorporates the ODM800 operator display module with a 16 x 40character backlit LCD display, simple alphanumeric keypad, 5 softkeys and a fast access key. The OCM800 operator control module provides all mandatory operator control keys and LED functions including Day/Night switching. Four control keys and 4 indication LEDs are provided for site-specific functions. Control keys and LEDs are labelled in German according to the default VdS functionality. The slide in decals can be reversed and alternative text added. The back box has a removable chassis plate with the PSM800 power supply, APM800 addressable PSU monitor and space for 2 x 7 Ah batteries to provide 72 h backup. The ZETTLER EXPERT Repeater with Power Supply is connected to the Panel via the remote bus (RS485, 1200 m distance). A maximum of 2 repeaters (including one MX REMOTE repeater) can be linked to each ZETTLER EXPERT panel and can provide full repeater functions for all panels on the system. The operator control module (OCM800) can support up to 80 inputs and outputs in the form of LED annunciators and IOB800 in/output modules. Product Codes Standard Repeaters 542.084 ZXF Repeater with shallow backbox 542.085 ZXFEV Repeater and addressable PSU Options 542.006 IOB-800 (8in/8out) expansion board

Page 7

ZETTLER Expert Modular Panels


FIM800 field interface PCB incorporating one or two MX DIGITAL loops . CPU800 32 bit processor and memory card . Optional network card, additional loop card (s) and remote diagnostic modem The panel has a lockable architectural front door with lockable window, which incorporates a modular user interface that fully complies with EN54:pt.2. The user interface incorporates the ODM800 operator display module with a 16 x 40character backlit LCD display, simple alphanumeric keypad, 5 softkeys and a fast access key. The OCM800 operator control module provides all mandatory operator control keys and LED functions including Day/Night switching. Two control keys and 2 indication LEDs are provided for site-specific functions. Control keys and LEDs are labelled in English according to the default LPCB functionality. The slide in decals can be reversed and alternative text added. The panel incorporates sufficient space to accommodate 2 x 17Ah or 2 x 38Ah batteries and sufficient space in the front door to take 2 or 6 additional user interface modules including 80 way red LED module (ANN880) , 40 way red/yellow LED module or 20 way status/command firemans interface module. . Product Codes Standard Panels 542.090 ZX4-M3 2 to 4 Loop panel in 3 tier housing 542.091 ZX4-M5 2 to 4 Loop panel in 5 tier housing Options 542.006 IOB-800 (8in/8out) expansion board (Max. 24 I/O on main panel) 542.007 XLM-MX two loop MX DIGITAL expansion card 542.010 TUD-800 German Transmission Unit 542.025 MX-FIL FILNET network card 542.026 TLI800 MX-NET Network card 542.036 Remote Diagnostic Modem 542.008 Modem lead 542.011 MX CONSYSDownload lead

The ZETTLER Expert Modular panels are intelligent LPCB EN54 approved panels, which can be networked to provide up to 396 detection loops and installed to BS5839:Pt.1. The ZETTLERExpert supports two Tyco MX DIGITAL detection loops and can be expanded to four loops supporting up to 1000 addressable devices. The modular panels are manufactured so they can be retrofitted into the TFX series of fire controllers, for upgrades. The construction of the modular units is not the standard 19 inch rack mounting system. The panel consists of a strong rack style steel enclosure which can be surface or semi-flush mounted. The main removable chassis plate holds: . PSB800 5A 24Vd.c. battery backed power supply and loop booster to EN54pt4

MX Detection Panels - Technical Specification & System Schematics


MX Detection Panels - Designer Housing Technical Specification
Dimensions (mm) Approx Weight Temperature (Storage) Temperature (Operating) Humidity Colour (Housing) Colour (Modules) EMC/RFI Shock Vibration Shallow Housing 320Hx440Wx120D 7Kg -20oC to +70 oC -8oC to +55o C Flush Shallow Housing Deep Housing 380Hx500Wx120D 320Hx440Wx215D 7.2Kg 8Kg -20oC to +70 o C -20oC to +70 oC -8oC to +55 oC -8oC to +55 oC up to 95% RH, Non-Condensing Dawn Grey (BS 4800 10A - 03) Pantone 431C EN 50130-4 EN 54-2 EN 54-2 Marine 320Hx440Wx135D 14Kg -20oC to +70 oC -8o C to +55 oC

MX Detection Panels - Modular Housing Technical Specification


Dimensions (mm) Approx Weight Temperature (Storage) Temperature (Operating) Humidity Colour (Housing) Colour (Modules) EMC/RFI Shock Vibration Lockable Window 3 Tier 588H x 600W x 200D 22.5Kg -20oC to +70 oC -8oC to +55o C 5 Tier 854H x 600W x 200D 31.5Kg -20oC to +70 o C -8oC to +55 oC up to 95% RH, Non-Condensing Dawn Grey (BS 4800 10A-03) Pantone 431C EN 50130-4 EN 54-2 EN 54-2 On MX4000M Versions Only

Page 8

DESIGNER HOUSING SCHEMATIC


24Vd.c. Non-Resettable 24Vd.c. Resettable Field I/O Network PC/Modem Printer

CPU PSB FIM Loop C XLM 110-240Va.c. Loop A Loop D Loop B TLI RBus

ODM

FRONT DOOR

OCM

MAIN PANEL HOUSING

XBus

TUD/ IOB

IOB

PSB/PSM MX FILNET

ANN880 ANN840 or COM820 FRONT DOOR

17 or 38Ah

17 or 38Ah

MPM

ANN880 ANN840 or COM820

BATTERY & EXPANSION HOUSING

Remote bus up to 15 addresses a combination of up to 7 x OCM and 15 x MPM Maximum

MODULAR/RACK HOUSING SCHEMATIC


24Vd.c. Non-Resettable Field I/O 24Vd.c. Resettable Network PC/Modem Printer

CPU PSB FIM Loop C XLM 110-240Va.c. Loop A Loop D Loop B TLI

R Bus

OCM

ODM

XBus ANN880 ANN840 or COM820

ANN880 ANN840 or COM820

MPM

PSB/PSM TUD/ IOB IOB MX FILNET

FRONT DOOR 17 or 38Ah 17 or 38Ah

BACKB OX

Remote bus up to 15 addresses a combination of up to 7 x OCM and 15 x MPM Maximum

Page 9

MX Panel Components
CPU800 Expert Central Processor
detection panels. The CPU-800 contains a Data Memory (SRAM), a Program Memory (Flash EPROM), a Configuration Memory (Flash EPROM) and a Boot ROM (EPROM). The use of flash EPROM allows program upgrades to be downloaded locally or remotely without the need for changing chips. The CPU-800 provides power for the following functions: . Full alarm and fault monitoring for up to 1000 addressable points including central loop processing of MX Fastlogic expert algorithms . Concurrent operation of the main user interface and 2 remote user interfaces including one remote dial up or networked user interface . Peer to peer interaction with up to 99 other MX detection panels . Cause and core effect using up to 1000 input, output groups, delay timers and logic functions The Board provides 4 serial channels to the FIM800 - 2 for RS232 (PCs, modems, printer and/or data loggers), 1 for the remote bus (RBUS) to the main user interface and repeaters and 1 for Network Port (FSI, ThornNet/MX Net or MX-FILNET) Technical Specification 32 bit Processor: Motorola 68331 Data Memory SRAM: 1 MByte Prog. Memory Flash EPROM: 2 MByte Config. Memory Flash EPROM: 1 Mbyte Boot EPROM: 64 kByte Number of serial Interfaces: 4 Quiescent Current: 67mA Alarm Current: 67mA Product Codes 557.202.002 (Spare only) CPU800 standard MX central processor (UK) 542.002 (Spare only) CPU800 standard MX central processor (EUROPE)

The CPU-800 provides the main processing power behind the MX detection panels. It is a multi-layer PCB and contains the CPU, the memory and interface electronics. The CPU-800 plugs into the Field Interface Module (FIM800) which forms the motherboard in most MX

FIM800 Field Interface Module


drivers on the FIM. This reduces downtime and maintenance costs. The FIM can also take a variety of loop cards to support other addressable loop protocols. The FIM incorporates the following local I/O connections: . 2 x reverse polarity monitored sounder outputs . 2 x volt free outputs (Default alarm and fault) . 1 monitored input (eg. Day/Night changeover) . 1 emergency alarm input . 1 unmonitored input (eg. Class Change or Tamper) . Full monitoring of PSB800 power supply . Ground fault monitoring The FIM incorporates a local I/O bus which allows the local I/O connections to be increased by 24. A variety of I/O expansion boards are available including: . IOB800 (8 in/8 out) expansion board . TUD800 German Transmission Unit The FIM includes two connections to the RBUS one for the local user interface and one for connecting up to 15 remote addresses in the form of up to 2 x operator control modules (OCM800) or up to 15 multi-purpose modules (MPM800). The FIM provides 3 configurable external serial ports : . Port 1 Local printer . Port 2 Configuration PC or remote diagnostics and upload/download modem . Port 3 FSI open protocol or Network card/gateway (TLI-800 or MX-FIL) Technical Specification Dimensions: 25H x 105W x 196D mm Weight: 156g Power Consumption:119mA (Quiescent excluding loops and operator interface) 169mA (Alarm) Relay Outputs: 30Vd.c. @ 2A Monitored inputs: 10k Ohm EOL, 3KHz in parallel RBUS: RS-485 , default 19.6kB, up to 1200m Serial Ports: RS232C, 19.6kB, up to 10m Local I/O Expansion:Up to 2 modules, up to 24 I/O, max. 300mm Product Codes 557.202.000 FIM801 field interface module with one MX loop driver (UK) 557.202.001 FIM802 field interface module with two MX loop drivers (UK) 976262 SIM Serial Isolation Module (UK) 542.000 FIM801 field interface module with one MX loop driver (EUROPE) 542.001 FIM802 field interface module with two MX loop drivers (EUROPE) 542.023 SIM Serial Isolation Module (EUROPE)

The Field Interface Module FIM is the main interface for field wiring on MX detection panels and contains plug-in field wiring terminals, inter board connectors, EMC protectors and filters and general I/O electronics. The FIM801 provides 1 x MX DIGITAL loop and the FIM802 provides 2 x MX DIGITAL loops. Each MX DIGITAL loop can support several kilometres of loop wiring using a mixed topology using multiple loops and spurs. Typically the MX DIGITAL loop supports up to 2km of MICC or equivalent soft skinned fire proof cable. The FIM provides up to 495mA of loop power to each loop to drive loop powered sounders and other loop power devices. An optional plug-in additional loop card (XLM800-MX) provides a total of 4 x MX DIGITAL loops. In the event any loop driver circuitry on the FIM becomes damaged a second loop card can be fitted to replace the loop

Page 10

FIM TO IOB800 CONNECTION DETAILS

MX Loop Expansion Module


The XLM800 Loop Expansion Module fits piggyback style onto the FIM or an existing XLM 800 and is used to: . Expand the capability of the MX4000C.I.E. two loop system to four loops . Replace the FIM loops in case of a failure on either a two or four loop system. The XLM800 Loop Expansion Module controls the communications between the detectors (and other ancillaries) connected on the 2-wire loop circuits and the controller. In addition, the addressable interface contains line isolation circuits which protect the loop driver circuit from short-circuit conditions. Technical Specification Dimensions: 17.5H x 104W x 196Dmm Battery Requirements: Standby 104.3mA + loop current Alarm 105.3mA + loop current Loop Current 495mA maximum Product Codes UK EUROPE 557.202.007 542.007 XLM-MX Two Loop MX Digital ExpansionCard

Page 11

MPM800 Multi Purpose Interface Module


Up to 15 x MPM modules can be connected to each panel of which 8 can be in the form of OCM800 (including the main OCM800 user interface). One OCM800 can also be in the form of an emulated user interface on a remote panel or PC connected via the network or dial up modem. The following I/O and LED annunciator modules can be slaved from an MPM800: . Up to 5 x IOB800 (8 in/8 out expansion board) . Up to 5 x XIOM800 (16 way universal I/O board) . One Mimic Panel (80 way LED mimic driver PCB) . One 80 way ANN880 LED mimic** . One 40 way ANN840 LED mimic using red & yellow LEDs** . Two 20 way COM820 LED status/command modules** The MPM800 is mounted by plugging directly onto the back of those items marked ** Technical Specification Dimensions: 25.4H x 92W x 167.64D mm Weight:: 98g Power Supply: 24Vd.c. (from PSB or PSM800) Power Consumption:35mA (Quiescent) 68mA Alarm subject to I/O modules fitted Communications: RS-485, up to 19.6kB Printer Connection: Serial or Parallel Product Codes UK EUROPE 557.202.012 542.012 MPM800 multi-purpose interface module 557.202.117 542.009 Serial printer cable for MPM800 or FIM800 976262 542.023 SIMSerial isolation module

The MPM800 is used to provide various expansion capabilities via the remote bus (RBUS). The MPM800 is provided as a standalone module but is also incorporated into the circuitry of the OCM800 operator control module to drive the LCD display, LEDs, keyswitch and keys on the OCM800 and the operator display module. The OCM800 and MPM800 have an XBUS which can be used to drive up to 80 I/O. The MPM800 also has a printer interface for connecting to a serial or parallel printer.

MPM800 TO XIOM CONNECTION DETAILS

Page 12

MPM 800 TO IOB800 CONNECTION DETAILS

PSM800 and PSB800 Power Supplies


Output reset) are provided. Battery voltage and charger current readings are also provided to the FIM or APM for automatic battery testing. Screw terminals provide 2 x 24V outputs (24 V stabilised, 24V stabilised with reset control) and one 5V output. The power supply is fitted in a steel cage with mounting points to allow any of the following boards to be mounted: . APM800 addressable power supply monitor . FB800 fuse board with 15 x 24Vd.c. fused spurs . IOB800 input/output expansion board Technical Specification Dimensions: 50H x 114W x 190D mm Weight: 0.9Kg Input Voltage: 120-240 Vrms, 50/60Hz (Auto ranging) Input Current: 0.8-1.6A RMS Rated Load Max. charge current : Up to 3.8A (dependant on standby current) Max. battery size(24hr charge): 38Ah Max. total supply current: 5A@24Vd.c. Maximum external current: 4A@24Vd.c. Output Voltages: 24Vd.c. (22.8 -26.4V) Non-resettable: 24Vd.c. @ 4A Resettable: 24Vd.c. @ 4A 5Vd.c. @ 3A Power Consumption:PSB - 90mA (quiescent & alarm) PSM - 65mA (quiescent & alarm) A PSB 800K Power Expansion Kit is required to power the XLM 800 pcb on 4 loop systems which require the extended loop power capability. It Page 13 consists of a PSB800 power supply module that comes with a loop booster module, an APM 800 addressable monitor module, a battery connecting cable and an XLM800 to APM800 connecting cable and maybe fitted onto the chassis plate in the battery housing.

The MX power supply module is a state-of-the-art integrated switch mode system power supply and battery charger, which can provide up to 5A external and auxiliary loop power during alarm conditions. It has a universal input allowing operation from 100 to 255 Va.c., 50 or 60 Hz. The power supply is approved* worldwide to EN54, UL864 and Marine standards. The charging voltage is temperature compensated. The PSM recharges the batteries within 24 h for the following timings: . 90h stand by time and 15 min. alarm condition . 72h stand by time and 30min. alarm condition The power supply provides full condition and fault monitoring to the system via the FIM (used by the PSB800) or addressable power supply monitor APM800 (used by the PSM800). The PSB800 incorporates the LBM800 booster module to provide the correct voltage levels to maximise the performance of the MX DIGITAL protocol. Faults signals (Loss of AC, Battery charger fault, Battery fault) and control inputs (Battery test,

Product Codes UK EUROPE 557.200.014 542.088 MXAPSU17 Boxed Addressable PSU (17Ah) 557.200.015 542.089 MXAPSU38 Boxed Addressable PSU (38Ah) Options 557.202.003 542.003 PSM800 Power Supply Only 557.202.403 NA PSM800M Marine approved power supply 557.202.005 542.005 PSB800 Panel Power Supply c/w Loop Booster 557.202.405 NA PSB800M Marine Panel Power Supply (spare) 557.202.027 572.018 APM800 Addressable Power Supply Monitor 557.202.050 NA PSM800 Temp. Sensor Accessory kit 557.202.040 542.200 PSB800K Power Expansion kit 557.202.004 LBM800 Spare Loop Voltage Booster PCB

FB800 Fuse Board


The FB800 fuse board provides terminations for 15 fused 24Vd.c. output spurs from a single 24V d.c. input. The FB800 is designed to be normally mounted on the PSB800 or PSM800 power supply. The fuses are rated at 500mA. Technical Specification Dimensions: 93H x165W x 80D mm Weight: 149g Input: 24Vd.c. (+10%/-5%) Output: 15 x 24V d.c / 500mA Terminations: 2.5mm Product Codes UK EUROPE 557.202.100 542.064 FB800 fuse board (15 way)

IOB800 Input/Output Expansion Board


The IOB800 is an LPCB & Vds approved* board that provides 8 opto-isolated digital inputs and 8 x 24V d.c. relay outputs for providing I/O expansion capabilities to MX detection panels for interfacing to other subsystems and signalling devices. The IOB800 also incorporates a connector, which provides decoded signals for the 8 inputs and 8 outputs for specialist interfacing. The IOB800 can be used to provide expansion I/O to the following MX panel components: . FIM801/802 field interface modules (maximum 16In/8Out) . OCM800 operator control modules (maximum 80 I/O) . MPM800 multi-purpose interface (maximum 80 I/O) The IOB800 can be mounted on the PSB800 panel power supply, up to two in the top of a battery box or repeater or in the back of a modular housing. The IOB800 has two expansion bus connectors which allow them to be daisy chained together. Technical Specification Dimensions: 15H X 164W X 80D mm Weight: 153g Power Consumption:29mA (Quiescent) 65mA (Maximum) Terminations: 1.5mm Product Codes UK EUROPE 557.202.006 542.006 IOB800 Expansion Board and cables

TUD800 German Transmission Unit


The TUD800 is a VdS approved* input/output module specifically designed for interfacing the ZETTLER EXPERT panels to the German Fire Brigade equipment. The TUD800 takes the place of an IOB800 when used and is typically mounted in the deep battery/expansion box. Technical Specification Dimensions: 15H x 164W x 80D mm Weight: 153g Power Consumption:29mA (Quiescent) 65mA (Alarm) Product Codes EUROPE 542.010 TUD800 German Transmission Unit

MX-FIL Filnet Gateway


Technical Specification Dimensions: 135H x 280W x 35D mm Weight (Approx): 330g Serial interfaces (electr. isolated): - No. Interfaces: 1 - Parameters (coding plugs): RS 232 / 422 / 485 - Baud Rates: Programmable LON-interface (incl. NIF): - No. Interfaces: 2 - Parameter FTT10 transceiver - Baud Rate: 78 kbit/s Voltage Supply: - From control panel or external PS: 0V / +24Vd.c. - Monitoring with XPSUMB: 0V / +5V / +24Vd.c. Power Consumption: - External interface gateway typ: 80 mA Digital Outputs (short circuit proof): - Number of open collector outputs: 8 - Current limitation: 50 mA Digital Inputs (overvolt. prot): - Number of electr. isolated inputs: 8 - Series resistance to the opto-coupler LED 4.7 kohm - Input voltage range 5 - 28 V

The Filnet Gateway is an EN54 Vds approved network gateway which allows up to 64 MX Panels to be networked onto a secure LONbased FILNET Network. The MX-FIL Gateway can be mounted in the designer battery box on the chassis plate or the inside of the modular housing.

Product Codes UK EUROPE 557.202.025 542.025 MX-FILFilnet Gateway

Page 14

MX Panel User Interface Modules


OCM800 Operator Control Module
display module to provide a complete panel user interface. In addition the OCM800 can drive up to 80 inputs/outputs using one of the following modules: The following I/O and LED annunciator modules can be slaved from an MPM800: . Up to 5 x IOB800 (8 in/8 out LPCB/VdS approved expansion board) . Up to 5 x XIOM (16 way universal I/O board) . One Mimic Panel (80 way LED mimic driver PCB) . One 80 way ANN880 LED mimic . One 40 way ANN840 LED mimic using red & yellow LEDs . Two 20 way COM820 LED status/command modules Up to 2 x OCM800 units can be connected to an MX panel via the internal or external RBus communication port. Technical Specification Dimensions: 50H x 232W x 133D mm Weight: 0.272Kg Power Consumption:35mA (Quiescent) 36mA (Lamp test) 81mA (Alarm) Control Buttons: 7 Indication LEDs: 18
RS-485: RBus Default 9.2Kb Expansion Bus: MINERVA/TFX X-Bus and MX X-Bus Legends for LPCB modules: UK/English, Marine, Dutch, Italian Legends for VdS modules: German, Spanish, Portuguese Communications:

The OCM800 is utilised by all MX detection panels and full function repeaters to provide mandatory operator control and LED indication functions to comply with EN54:pt.2 and UL864. The OCM800 is fully programmable but operates in default configurations according to the software template used. Most software templates allow several of the LEDs and control buttons to be programmed for site-specific functions. The LEDs and control buttons both have slide in legends to suit the default configurations and language. Standard panels include the appropriate legends for their relevant markets. The OCM800 incorporates the functionality of an MPM800, which allows it to drive an operator

Product Codes 557.202.013 OCM800 with Minerva MX Inserts 542.014 OCM800 with Zettler Expert Inserts 557.202.101 Danish OCM Firemans Keyswitch Assembly 557.202.064 MX/ZX OCM800 Inserts - Dutch (PK10) 557.202.065 MX/ZX OCM 800 Inserts - Italian (PK10) 557.202.063 MX/ZX OCM800 Inserts - Spanish (PK10) 557.202.066 MX/ZX OCM800 Inserts - Portuguese (PK10)

Page 15

OCM800 TO IOB800 CONNECTION DETAILS

ODM800 Operator Display Module


control keys: . 0-9 alpha-numeric phone style keypad . Up and down scroll keys . Fast access key for quick access to commonly used functions . Five function keys The ODM800 is powered and controlled by the OCM800 operator control module and provides various functions according to the panel software. Standard EN54 panels use the LCD display as five windows on the system. Window 1-Details of first detector in alarm Window 2-Details of the most recent detector in alarm Window 3-System Status including Alarm/Fault and Isolate counters Window 4-Full alarm/event details and lists including 95 character procedure plus full password controlled system manager, service and engineering menu structure Window 5-Function key legends (eg. Back, Enter, >>,<<) Technical Specification Dimensions: 25H x 232W x 133D mm Weight: 0.361Kg Power Consumption:50mA (Quiescent) 900mA (Alarm Backlit) 50mA (Alarm during mains failure) Product Codes UK EUROPE 557.202.019 542.019 ODM800 operator display module 557.202.103 Danish ODM 800

The ODM800 operator display module provides a powerful and flexible 40 x 16 character backlit LCD display used by all MX detection panels and full function repeaters. The ODM800 is used with the OCM800 to provide a fully compliant and approved user interface for UL and EN54 fire detection panels. The ODM800 also includes the following operator

ANN840 LED Annunciator


The ANN840 is a standard LED annunciator user interface module which can be driven from an OCM800 or an MPM800. The MPM800 can be mounted remotely or piggy-backed on the ANN840. The ANN840 has removable legends for 40 zone status indicators. Each zone can indicate RED (eg. Alarm) and YELLOW (eg. Fault & Isolate). The functionality is programmed in the MX detection panel. The ANN840 operates as 80 outputs (RED & YELLOW). Technical Specification Dimensions: 25H x 232W x 133D mm Weight: 177g Power Consumption: 1mA + MPM800 (Quiescent) 85mA + MPM800 (25% zones in alarm (Alarm)) 340mA +MPM800 (Lamp test) Product Codes UK EUROPE 557.202.021 542.021 ANN840 LED annunciator

ANN880 LED Annunciator


The ANN880 is a standard LED annunciator user interface module, which can be driven from an OCM800 or an MPM800. The MPM800 can be mounted remotely or piggy-backed on the ANN880. The ANN880 has 80 red LEDs numbered 1 to 80. The functionality is programmed in the MX detection panel but is defaulted to zone alarm LEDs. Technical Specification Dimensions: 25H x 232W x 133D mm Weight: 177g Page 16 Power Consumption: 1mA + MPM800 (Quiescent) 85mA +MPM800 (25% zones in alarm (Alarm)) 340mA + MPM800 (Lamp test) Product Codes UK EUROPE 557.202.022 542.022 ANN880 LED annunciator

COM820 Status Command Module - 20 Way


The COM820 is a standard user interface module, which can be driven from an OCM800 or an MPM800. The MPM800 can be mounted remotely or piggy-backed on the COM820. The COM820 has removable legends for 20 status command functions. Each function includes a command button and a red status LED. The functionality is programmed in the MX detection panel. Typical applications include: . Manual/OFF/Auto/Isolate functions for evacuation or plant control . Selective isolate and evacuate functions for firemans control . Selective plant shutdown and override functions . Selective system delay and timer functions 2 can be driven from 1 x MPM800. Technical Specification Dimensions: 25H x 232W x 133D mm Weight: 204g Power Consumption: 0.267mA (Quiescent - No LEDs) 5mA (Alarm - 25% LEDs) 21mA (Lamp test) Product Codes UK EUROPE 557.202.020 542.020 COM820 Status/Command Module

Input/Output Expansion Cards (XIOM)

The XIOMis a 16 universal input/output expansion board. The I/O on the XIOM can be set in banks of 8 to operate as follows: . LED driver outputs (10mA source) . Relay Driver Outputs (100mA sink) . Voltage Monitor Input (8 - 30Vd.c. Normal) . Volt Free Contact inputs

Technical Specification Dimensions: 144H x 85W x 15D mm Operating Temp: -10 to +65C Storage Temp: -20 to +65C Relative Humidity: 95% RH (Non-Condensing) Power Consumption:11mA (Quiescent) 16in - 80mA (Max) 16out - 160mA (Max)

Product Code 557.180.016 XIOM MINERVA Input/Output Expansion Module (16 Way)

Remote Mimics
the MINERVA MX addressable system. It is supplied as a single PCB, which may be mounted in an expansion box or on the rear of a freestanding panel, as required. It may be used to drive up to 80 zonal LED indicators, arranged in any configuration, together with two FIRE LEDs, one FAULT LED and one ISOLATE LED. These indicators can operate in the same manner as the corresponding indicators on the panel. A remote Mimic can be connected to the MPM800s configured as remote Mimic drivers via the remote bus. Up to 15 MPM800s may be connected on to the remote bus, each with a unique address [set on-board]. The Mimic includes audible and visible warning facilities. Technical Specification Dimensions: 235H x 190W mm Operating Temp: -10C to +55C Storage Temp: -20C to +65C Relative Humidity: Up to 95% RH Non Condensing Power Consumption:11mA (Quiescent) 200mA (25% Alarm) 800mA (Lamp Test) Product Code 557.180.005 MINERVA 80 way mimic driver module

The 80-Way Mimic allows custom-made display and presentation panels to be incorporated in

Desktop Printer
Features 300 cps draft/ 90cps LQ. Quiet operation Lightweight and compact design 9 LQ fonts 2 paper feed paths Convertible push/pull tractor Paper guide Auto loading Paper park Cable feed recess Epson LQ standard terminal emulation available Parallel and serial interface Technical Specification Dimensions: 159H x 366W x 275D mm Weight: 4.4kg Operating Temp.: 5C to 35C -15C to 40C 10% to 80% RH [non-condensing] Operating Voltage: 180V to 264Va.c. EMC: BS EN 50081-1 and BS EN 50082-1 Product Codes UK EUROPE 557.180.239 MINERVA printer LQ-300+ 557.180.220 LQ80 ribbon black (spare) for use with desktop printer. 557.202.117 542.009 MX FIM/MPM to serial printer lead Storage Temp.: Relative Humidity:

The printer is designed as a low cost business printer ideally suited for mounting adjacent to the fire control panel.The LQ-300+ combines high performance with paper handling flexibility and quiet operation.

Page 17

In-built Printer
Features . A thermal printer mechanism which ensures high reliability. . Quiet Operation . Lightweight and Compact Design . High Speed Printing: 40mm per second. . High quality printing: 384 dots. . 32 Columns . Friction paper feed Technical Specification Dimensions: 230H x 137W x 85D mm Weight: 0.38Kg Operating Temp: +5C to +45C Storage Temp: -20C to +70C Relative Humidity: Up to 80% non-condensing EMC: BS EN 50081-1 for emissions BS EN 50082-1 for immunity Product Codes 557.202.024 PRN 800 Printer c/w front cover module 557.301.014 Spare Paper Roll (pk of 5)

The PRN800 Printer Kit is designed for use with the designer range of MX Controllers (MX1000, MX4000 and T2000). It is fitted to the front cover of the MX battery housing and is powered from the PSB 800 power supply via an FB800 fuseboard in the MX Controller housing.

Remote LCD Display


Features . Uses a backlit 4x20 character alphanumeric display. . Provides an internal log of up to 150 events. . Provides internal audible warning of an event. . Allows the event log to be scrolled. . Local internal buzzer silence. . Connects to host panels RS232 port (maximum cable length between panels and first repeater of 15m). . Provides an external sounder to mimic the internal buzzer. . Can be connected to an unlimited number of other LCD Repeaters by using the RS232/RS422 converter (Up to 1200m between repeaters). The LCD repeater must not be used in the primary fire path. It must not be used as the sole warning that a fire exists. Technical Specification: Dimensions: 150H x 200W x 75D mm Material: Bayblend polycarbonate/ ABS alloy -10 C to +55 C Up to 95% RH NonCondensing Power Supply: 200mA @24Vd.c. Ext. Sounder Relay: 500mA@24Vd.c. EMC: Product Family Standard EN50130-4 in respect of Conducted Disturbances, Radiated Immunity, Electrostatic Discharge, Fast Transients and Slow HighEnergy. EN50081 -1 for Emissions. Product Codes 557.200.024 Remote LCD Repeater (compatible with Version 2.1 and above) 557.202.117 MX Printer Lead 557.180.152 9-Way gender changer 557.180.151 RS232/422 converter for LCD Repeaters. Operating Temp: Relative Humidity:

The Remote LCD Repeater Module is designed to provide an independent scrolling log of system status at numerous points within a building or site. The module interfaces directly to a serial printer port of the MX addressable fire panel. If a local printer is already connected to the Panels MPM800 serial port, a second MPM800 must be used.

Cables & Other Modules


Product Codes UK EUROPE 557.201.300 542.047 BFP801 Spare blank user interface module 557.202.116 542.008 FIMModem lead 557.201.305 542.052 Designer door complete with hinges and brackets 557.201.301 Standard MX Panel designer backbox and chassis plate 976254 542.031 Set of spare keys for MX Panel 557.201.302 542.049 Deep MXDesigner backbox and chassis plate 557.201.306 542.053 Standard MXExpansion backbox and chassis plate 557.201.310 542.049 Deep MXExpansion backbox and chassis plate 557.202.113 PSB to FIM Cable

Page 18

MX Graph/MXNet
MXGraph
zoom magnifications are all imported from AutoCad. This configuration tool significantly reduces configuration time, increases the integrity of information and enables simple updates to the system in the future. Features Combined text and graphics display on a single P.C. Connected to MXNet, a single system can be used to monitor up to 99 MX fire controllers Designed for touch screen operation Simple operator controls, no Qwerty keypad High resolution colour SVGA display Windows NT TM multi-tasking operating system Four level automatic zoom sequence available for each point Overview map maintains a view of wider areas whilst zooming into detail in the graphics window Procedure window provides additional text and operator instructions for each event Classification of events helps to maintain a record of activation and the causes Browse icons placed on maps can be used to pan across an installation in a logical sequence Control icons placed on maps can be used to initiate actions at the MX fire controller, used to operate ancillaries such as HVAC Automatic configuration using the GRAB-IT tool, including Cad drawings, text messages, locations, flood fills and zoom areas Full password protection and multiple operator levels Remote control of MX fire controller across the network Real time on line event management and historic information system User designed search keys can be used to generate specific and useful reports Available in English, Dutch and Spanish MXGraph can be connected to up to 99 networked MX fire panels using the LPCB approved MXNet. MXGraph will also be available for use with up to 64 MX fire panels networked using the LON based VdS approved FILNET. MX net will support up to 3 fully operational MXGraph user interfaces on a network plus additional units operating as graphical mimics. MXGraph consists of a standard personal computer, that is linked onto the MXNet via a TLI800 network interface module. MXGraph is primarily operated by either mouse or touch screen, with the two monitor options available 17or 22touch screen. For an up to date specification of the latest approved PC platform, contact the Fire Product Manager. Product Codes 508.020.007 Compatibility tested PC for MX & ThornGraph graphics terminal preloaded and configured with default passwords 508.020.006 22 inch IIyama Touch Pro 636.006.060 17 inch Standard monitor 508.020.201 Software package A for 1 network node 508.020.202 Software package B for 2-5 network node 5 508.020.203 Software package C for 6 or more network nodes 508.020.204 Software package D for additional graphics nodes on the same MXNet MXGraph is functionally similar to Thorngraph. For full details of upgrade paths contact the Fire Product Manager.

Introduction MXGraph is a fully integrated graphical and text user interface for use with MINERVA MX , ZETTLER EXPERT and MINERVA T2000 networked fire panels. Whether the installation uses a single sub-panel or up to 99 networked sub-panels, MXGraph provides a seamless integrated graphical mimic with full alarm management and panel control capability. MXGraph has been designed with clear displays and simple controls which can be quickly and easily understood by an operator rather than an engineer. The system is designed to be used with a touch screen or mouse and does not require the use of a Qwerty keyboard. Using the secure acknowledged transfer of events, up to three MXGraph systems can be used to monitor up to 99 MX controllers connected to an MXNet. MXGraph uses a unique configuration tool GRABIT, (Graphical, AutoCad, Bitmap, Information, Transfer) to automatically configure the system. Installation plans, device type and location, flood fill areas, flood fill locations, zoom areas and

MXGraph Typical Arrangement

Max distance between nodes is 1000m using MICC cable

Max distance between nodes is 3000m using twisted/shielded pair cable TLI800 Network Interface

TLO530 Fibre Interface

TLO530 Fibre Interface

Max distance between nodes is 4000m using fibre optic cable

Page 19

MXNet & ThornNet


ThornNet is a high integrity LPCB approved peer to peer communication network which has been tried and tested over 1000 major fire detection installations around the world. This network is now also available as MXNet for networking MX panels together. For use with MX panels ThornNet has been enhanced to allow up to 99 nodes on a network and to carry new types of message. This enhanced network retains all the features and resilience of ThornNet and uses all the same hardware and cabling. MXNet provides a true peer to peer communications interface for up to 99, MINERVA MX, ZETTLER EXPERT or MINERVA T2000 fire controllers in any combination and the MXGraph, graphical user interfaces. The units can be interconnected into a large network without the need for a host or master controller. MXNet is based upon a combination of hardware and software that allows MX fire controllers (Nodes) to be linked together. The MXNet supports up to 99,000 analogue/addressable points and over 49,000 digital I/0 points. The network co-ordinates and distributes alarm annunciation and supervises system operation. When connected to the network, each MXFire controller maintains its full stand-alone features, functions and capabilities. Features LPCB approved A peer to peer network that does not use a host or master controller. 99 nodes, 99,000 points, 23,760 zone capacity. Bi-directional signaling. Open/short circuit isolation. Events originating at any node can be used as an input to event/action processing of other panels to co-ordinate and distribute systems control. System can be configured in the field using MX Consys software. Failure of one node does not affect any other node or communications between nodes. In the event of multiple failures, nodes will automatically re-generate into independent fully functional networks. Automatic network re-configuration when a previously failed node is restored to the network. Up to 3,000 metres between nodes with twisted/shielded cable. System will operate on standard 2 core MICC. MX controllers may be grouped into sub-nets where each panel is programmed to inter-act only with other selected controllers. Plug-in module (TLI-800) easily connects an MX fire controller to the network. Data is re-generated at each MX controller and is sent out over the MXNet as new clean data. All degradation in received data due to noise on a line, line attenuation, or phase shifting is eliminated when the data is re-generated. The MXNet uses a token-passing, non collision communication protocol for data transmission. "Network zones" and "sectors" allow the network controllers to be configured as a single "seamless" system. MXGraph, a P.C. based graphical user interface, connects directly on to the network. MXNet supports combinations of MICC, twisted/shielded pair cabling, fibre optic cabling, and dedicated telephone line. Multiple communication topologies bus or ring. See separate documentation for full details of MXFILNET VdS approved networking alternative to MXNet. ,

TLI-800
The key hardware component that makes the network possible is the LPCB & UL approved network card TLI-800. The TLI-800 provides the electrical/mechanical means to connect the components of the network to local and remote network signalling circuits. Installation of the TLI800 is simplified with an edge connector that plugs onto the main processor board of the MX controller. The TLI-800 provides RS-485 communications over a twisted shielded pair as a standard configuration. The distance between controllers can reach 3,000 metres at a speed of 38.4 Kbs using 18AWG twisted shielded cable. It fits within the MX panel housing. Later versions of the MX Panel software will be compatible with ThornNet and TFXNet. This uses the TLI/TLK530 network or the TLI-800 with different firmware.

557.202.026 TLI-800 MXNet network node interface module NOTE: TLK-530 and TLK530-G can be upgraded to TLI-800 and TLI-800G with a firmware change.

557.200.038 TLI-800G ThornNet interface for MXGraph PC c/w 240V PSU and housing 557.180.219 MXGraph PC to TLK-530-G & TLI-800G connection cable

TLO-530
The Fibre Optics Module (TLO-530) is used to interface one fibre optic channel to the TLI-800 module. The TLO - 530 fibre optic interface module converts RS-485 digital data current pulses from the TLI-800 network interface module to light pulses. The light pulses are then carried over fibre optic cabling to another TLO-530 where the pulses are converted back to RS-485 digital data current pulses. Two TL0-530 modules are required per panel for redundant path star connections and when using fibre optics in both directions of ring and bus connections. Two (2) type 62.5/125 fibres between controllers (4 fibres when using redundant path star connections) allow the interface to transmit signals at 38.4 Kbs at distances as high as 4,000 metres between controllers. Up to two units can be fitted into a TLO/TLD Housing which has a chassis plate to accommodate the units. Technical Specification Dimensions: 210H x 130W x 30D mm Weight: 460g Product Codes 976166 TLO 530 ThornNet/MXNet fibre optics interface assembly 557.180.148.A TLO/TLD Housing - ADT branded

TLD-530
The Telephone Line Drive Module (TLD-530) is used to interface two (2) dedicated telephone line circuits to the TLI-800 module. The TLD-530 line driver module converts the RS-485 signals received from the TLI-800 network interface module to signals capable of being transmitted over the telephone line circuits. One TLI-800 supports two channels so only one module is required per controller for both single path and redundant path star connections. The interface allows for field configured baud rates and supports distances of up 3,000 metres. Up to two units can be fitted into a TLO/TLD Housing. Page 20 Technical Specification Dimensions: 170H x 120W x 20D mm Weight: 140g Product Codes 557.180.699 TLD 530 ThornNet/MXNet direct line driver PCB 557.180.148.A TLO/TLD Housing - ADTbranded

MINERV A Solo Detection Panels


The MINERVA SOLO universal loop card currently supports the following protocols: . Apollo Series 90, XP95 and Discovery protocols . Hochiki ESP protocol . Nittan AS protocol Technical Specification Dimensions: 320H x 440W x 120D mm Approx Weight: 7Kg (without batteries) Temp. (Storage): -10 to +55 oC Temp. (Operating): -10 to +40 oC Humidity: 0 to 95% RH EMC/RFI: EN 50130-4 Shock: EN54-2 Vibration: EN54-2 Colour: Dawn Grey Pantone (BS4800 10A-03) Outputs: 5 Monitored outputs 5A@24Vd.c. Repeater Bus: RS485 Max. 1.2Km Max.16 repeaters Approvals (pending): EN54:2 EN54:4 Loop power: 495mA (standard MX loop card) Battery Capacity: Up to 12Ah (internal) Up to 17Ah (external) Product Codes UK EUROPE 557.300.001 MXS 8 Minerva Solo One Loop 8 Zone Panel. 557.300.002 542.094 MXS 16 Minerva Solo One Loop 16 Zone Panel 557.300.005 MXS8 Minerva Solo One Loop 8 Zone Panel (Flush) 557.300.006 MXS16 Minerva Solo One Loop 16 Zone Panel (Flush) 557.301.006 542.106 Minerva Solo MX Loop Card (Spare) 557.301.101 542.104 Solo Consys-Configuration Software Key for MX/Apollo/Hochiki/Nittan Protocol 557.301.012 Programming Lead for connecting a laptop to the Minerva Solo 557.300.003 MXS 8R Minerva Solo Full Function 8 Zone Repeater 557.300.004 542.096 MXS 16R Minerva Solo Full Function 16 Zone Repeater 557.301.007.P MXS Loop Card for use with Apollo protocol 557.301.007.H MXS Loop Card for use with Hochiki protocol 557.301.007.N MXSLoop Card for use with Nittan protocol 557.301.005 MXS/PRN Panel Mount Thermal Printer 557.301.011 MXS CPU to printer lead 557.301.014 Spare paper for Panel Mount Thermal Printer (pk5) 557.301.102 542.105 Qwerty Keyboard for programming text descriptions into Minerva Solo. 542.107 Zettler Solo TU Module 542.095 MXS 16 Zettler Solo two Loop 16 Zone Panel

Features . Single MX DIGITAL loop 8 to 16 zone detection panel . LPCB approved to EN54:pt.2 and pt.4 . Auxiliary loop power . MX VIRTUAL detectors . Fully programmable with front panel programming option . Optional integral event printer . 2 x 40 Character text display . Pre-alarm functions . Display of temperature, CO and smoke levels . Supports day/night detection modes . Supports MXSOLO Remote diagnostics . Optional full function repeaters . Optional service upgrade universal loop card The MINERVA SOLO use Tyco MX technology to provide a highly featured yet cost effective fire detection panel. The MINERVA SOLO is a single loop LPCB approved EN54 detection panel available in 8 and 16 zone models. MINERVA SOLO panels provide a highly featured and fully approved alternative to conventional detection systems in small to medium multi-occupancy, commercial and industrial buildings. The MINERV A SOLO also allows systems with existing addressable detectors to be upgraded to the latest panel technology and benefit for the service and central station monitoring offered by Tyco companies.

Loop back to panel

Solo Detection Panel System Schematic


Max 1.2Km

220-240Va.c.

24V.d.c.

24 Vd.c.
Callpoint

MSR Repeater

MSR Repeater Fire output Fault output Sounder 1 Sounder 2 Aux. output

MXS 8/16

PIM

CIM

557.301.005 MSPPrinter

MIM

SNM

MX Virtual Detector

Sounders

557.301.012 Programming Lead 557.301.102 Keyboard


DIN Callpoint

DIM

ASCII Qwerty Keyboard


Conventional Detector

Laptop SOLO Remote

Page 21

Batteries
Product Codes 660.001.003 Battery sealed L-A 560.001.013 Battery sealed L-A replaces parts 3145 and 30-102. 3085 Battery sealed L-A replaces 660.001.014 and 30-111 3010 Battery sealed L-A replaces 660.001.007, SLA21 and 30-103 3071 Battery sealed L-A 30-105 660.002.010 Battery sealed L-A 30-112 3072 Battery sealed L-A and 30-110 660.002.012 Battery sealed L-A 30-110 replaces 660.001.009 and 560.001.016 Battery sealed L-A replaces 3148, SLA17 and 30-109 660.001.004 Battery sealed L-A (Bolt terminal) replaces 3014, SLA24 and 30-106 560.001.012 Battery sealed L-A replaces 3149, SLA38 and 30-107 3150 Battery sealed L-A replaces SLA65 and 30-108

replaces 3146, SLA04 and

replaces 660.001.005, SLA07

replaces 3147, SLA012 and

Product Codes 660.001.003 560.001.013 3085 3010 3071 660.002.010 3072 660.002.012 560.001.016 660.001.004 560.001.012 3150

Model No. NP1.2-6 NP10-6 NP1.2-12 NP2.1-12 NP2.8-12 NP4-12 NP7-12 NP12-12 NP17-12 NP24-12B NP38-12 NP65-12

Voltage (V) 6 6 12 12 12 12 12 12 12 12 12 12

Ah 1.2 10 1.2 2.1 2.8 4 7 12 17 24 38 65

Dimensions (mm) Length Width Height 97 25 54.5 151 50 97.5 97 48 54.5 178 34 64 151 50 97.5 90 70 106 151 65 97.5 151 98 97 76 180 165 175 166 125 179 165 170 350 166 174

Page 22

MX VIRTUAL Multi-Sensor Detectors


Key Features
Construction & Technical Specification The 800 Series detectors are supplied in an extremely robust and reliable fully sealed construction, which has undergone stringent environmental and Marine type testing. All electrical contacts are moulded into the plastic to eliminate any movement. The detectors are constructed from hardwearing Fire Resistant FR110 plastic. The multi-sensor detectors are environmentally friendly. They use no radioactive parts and can be returned to the factory for recycling at the end of their life. All 800 Series detectors are supplied with integral dust covers as part of the packaging. Dust covers are retained throughout installation and removed at commissioning time. Unique design of the 801PH optical chamber provides immunity to thrips and other small insects without the need for metal gauze. Introduction & Key Features The 800 Series are addressable multi-sensor fire, smoke and heat detectors, which can be implemented as several MX VIRTUAL detectors by the MX detection panel. The 801 and 811 Series are designed and approved to EN54, the 801 Series carry land based approvals and the 811 Series also carry Marine approvals. The 812 Series are designed and approved to UL specifications and the 814 Series to Australian SSL specifications. The 800 Series of MX VIRTUAL detectors provide the latest fire detection technology in an attractive cost effective package. Key Features . Over 20 Fire Detection modes . Tyco MX FASTLOGIC Expert Algorithms . MX HPO detection algorithms . Tyco CO fire detection technology . Up to 250 detectors per loop . Optional bi-directional line isolation with every detector . Remote detector verification & temperature read-out . Highly featured MX SERVICE tool . Programmable Alarm LED with 360 o viewing angle . Optional detector locking pin . Variety of sounder and relay detector bases . Address flag stays with the base . Internationally approved Installation & Service Features The 800 Series MX VIRTUAL detectors include a host of installation and service features which are provided to reduce installation and service costs and reduce repair times. . Standard and 6 bases with multiple mounting options speed and simplify installation . Unique park position for commissioning and service procedures. . Detector Addressing programmed from the MX SERVICE Tool or MX Panel . Address flag fixed to the base to prevent mix ups during service . Compatible with Tyco 600 and 900 Series bases for easy upgrade . Panel Auto-Config and Self learn functions supported by the detectors

. . . .

Detector Service functions allow 800 Series detectors to be automatically addressed Full range of remote installation and service tools Dirty Detector Read-out can be viewed on the MX SERVICE tool or panel. Serial Number and Manufacturing data is also available from the MX SERVICE tool. Technical Specification Dimensions: Dia 109mm /43H mm (54mm with standard base) Weight: 0.124kg (Detector only) 0.192kg (Detector/Std Base) Power Consumption:150A (Quiescent) 2 to 5mA (Alarm) Loop voltage: Min. 20.0V/Max. 37.5V (MX Digital) LED: Single red LED (function programmable) Material: Body, cover and base FR110 BAYBLEND Fire Resistant Temp. Measurement: Accuracy +/-0.25 oC Resolution 2oC Operating Temp.: See specific detector Storage Temp.: See specific detector Relative Humidity: 95% non-condensing Shock/Vibration/Impact: prEN54:pt.7 Corrosion: prEN54:pt.5 and prEn54:pt.7 EMC/RFI: EC Directive 89/336/EC Outputs: Remote indicator & control output for relay and sounder bases Internal memory: Total 128 bytes / 32 bytes for service information including: - Detector dirty level - Date of manufacture - Date of commissioning - Address - Event history etc.

Page 23

Detection Modes
All 800 Series detectors communicate to the MX detection panel using the fast reliable MX DIGITAL loop protocol. This allows each detector to operate in one or two of several detection modes, thus allowing it to be easily optimised to the risk. To meet detection applications with multiple risks the 800PH and 800CH detectors allow two detection modes to operate simultaneously.

Virtual Detectors
The use of virtual detection means that installations can change the detection mode without any physical change, taking place. Not only can the detection be changed at the time of installation and commissioning but also during the life of the building as building usage changes. Some MX detection panels even allow the detection mode to be changed at different times of the day or automatically as occupancy and activity in the space changes. As well as providing great flexibility, using only two detector models means whole life costs are reduced by reducing manufacturing, stocking and service stocks. This also reduces the number of times detectors have to be changed during the life of the installation.

The 800PH Series support the following detection modes incorporating MX FASTLOGIC expert algorithms: . Multi-sensitivity Optical . Temperature compensated optical (HPO) . Fixed temperature heat . Rate-of-rise heat

The 800CH Series support the following detection modes: . Multi-sensitivity Carbon Monoxide . Temperature Enhanced CO (CCO) . Fixed temperature heat . Rate-of-rise heat

To complete the range the 800H heat only detectors support fixed heat, rate-of-rise and high temperature detection modes.

The 800I Series of ionisation detectors are also available for some markets.

800PH Multi-Sensor Smoke and Heat Detectors


The 800PH is a state-of-the-art smoke and heat detector which allows a full set of detection modes to be implemented in the MX detection panel to suit most smoke and heat detection applications. The 800PH incorporates a unique mousehole design optical chamber with an unrivalled signal to noise ratio providing high resilience to dust and dirt which means reduced service costs. In 801PH Optical Yes* Enhanced Optical (HPO) Yes* Normal Ambient ROR A1R Fixed Heat A2S 60o C Certification LPCB/VdS * Approved with MX Fastlogic algorithms Product Codes Branding 801PH 811PH ADT 516.800.500.A THORN 516.800.500.T 516.800.507 WORMALD 516.800.500.W 811PH Yes* Yes* A1R A2S 60oC Marine addition a unique chamber cover actually draws slow moving smoke into the chamber to provide a more responsive detector. The unique design provides immunity to small insects and thrips without the need for a separate thirp filter. The 800PH provides all the features of MX VIRTUAL detectors including self verification, temperature and smoke level indication and unrivalled service functions. Technical Specification Dimensions: 109dia x 43H mm Operating Temp.: -20 to +70 oC Storage Temp.: -40 to +80 o C Relative Humidity: 95% (non condensing) Standards: prEN54 pt 5, prEN54 pt 7

ZETTLER 562.000

TYCO 516.800.500.Y

Page 24

800CH Multi-Sensor Carbon Monoxide Fire Detectors


The 800CH is a state-of-the-art carbon monoxide and heat detector which allows a full set of detection modes to be implemented in the MX detection panel to suit most fire and heat detection applications. The 800CH is particularly well suited to sleeping risks, storage areas and applications where smoke detector positioning is difficult or where smoke detectors are prone to false alarm. The integration of heat detection into the 800CH allows the detector to operate in a wide variety of applications where combined risks Carbon Monoxide Enhanced CO (CCO) Normal Ambient ROR Fixed Heat CCO plus ROR (A1R) Certification Product Codes Branding 801CH 811CH ADT 516.800.501.A THORN 516.800.501.T 516.800.508 801CH Yes Yes A1R A2S 60oC Yes LPCB 811CH Yes Yes A1R A2S 60 oC Yes Marine ZETTLER 562.001 mean that CO detection alone would be insufficient. The 800CH incorporates a reliable electrochemical CO detection cell and high specification low thermal mass thermistor for accurate temperature detection. The 800CH provides all the features of MX VIRTUAL detectors including self verification, temperature and CO level indication and unrivalled service functions. Technical Specification Dimensions: 109dia x 43H mm Operating Temp.: 0 to +55o C Storage Temp.: -20 to +55 oC Relative Humidity: 95% (non condensing) Standards: prEN54 pt 5 prEN54 pt 7 TYCO 516.800.501.Y

WORMALD 516.800.501.W

800H Heat Detectors


The 800H is a flexible cost-effective addressable Dimensions: 109dia x 43H mm heat detector with all the features of MX VIRTUAL Operating temp.: -25 to +70 o C(-40 to +90oC detectors. The 800H returns the temperature to for short periods) the MX detection panel which allows various Storage temp.: -40 to +80 o C detection modes to be implemented. The 800H Standards: prEN54:pt.5 uses a high quality thermistor with very low thermal mass. This allows the detectors to 801H 811H provide fast accurate temperature detection as High Ambient ROR CR CR well as heat detection. Normal Ambient ROR A1R A1R Fixed Heat A2S 60o C A2S 60 oC Technical Specification Certification LPCB/VdS Marine Product Codes Branding ADT THORN WORMALD ZETTLER TYCO 801H 516.800.502.A 516.800.502.T 516.800.502.W 562.002 516.800.502.Y 811H 516.800.509

800I Ionisation Smoke Sensors


The 800I ionisation detectors are offered for old specifications which still call for ionisation smoke detectors. The 800CH and 800PH detectors offer improved performance, significantly lower false alarms and environmental compatibility for smoke detection applications. The 800I nevertheless offers state-of-the-art ionisation smoke detection with self verification, smoke level indication and threshold compensation for detector condition monitoring. The 801I is LPCB approved. Product Codes Branding ADT 801I 516.800.515.A THORN 516.800.515.T Technical Specification Dimensions: 109dia x 43H mm Operating Temp.: -20 to +70 o C Storage Temp.: -40 to +80 oC Relative Humidity: 95% (non condensing) Standards: prEN54 pt 5 prEN54 pt 7

WORMALD 516.800.515.W

ZETTLER NA

TYCO 516.800.515.Y

Line Shorting Adaptor


Product Codes 517.050.002.A Low profile line shorting adaptor commissioning tool (shorts terminals together enabling cable resistance checks to be carried out) - ADT Branded 562.004 Low profile line shorting adaptor commissioning tool (shorts terminals together enabling cable resistance checks to be carried out) - Zettler Branded

Page 25

Detector & Mode Selection & Design Charts Detector Selection Chart
This chart is designed to assist with the selection of the best detector for the risk. 1. First select the environment 2. Next select the fire loading or risk being protected. The corresponding square shows the best suited (bold) and other suitable detectors for the application.

Page 26

Detector Mode Selection Chart


This chart is designed to assist with the selection of the best detector mode to be implemented during system configuration. Once the most suitable detector has been selected (see detector selection chart on previous page) this chart can be used to find the best detection mode for occupied (day) and unoccupied (night) applications.

E = Temperature enhanced E+H = Temperature enhanced and heat detector together H = Heat only part of combined detector X = Callpoint protection alone

Bold text indicates most likely detector/mode to meet users requirements. Letters in brackets represent recommended sensitivity settings. *Not available as part of 800 range. #Not LPCB approved

Table is for guidlines only and specific situations are likely to require variations on the suggested detector types. Real situations may require detector combinations to cover all likely risks. Night and Day columns represent low false alarm risk and high false alarm risk, although this usually follows a day/night pattern, it may be configured for any time. For example the car deck of a ferry would be configured for Day during vehicle loading and Night once all the passengers had left the car deck, thus achieving optimum protection for that area. If fastlogic operation is selected for optical detectors, the same table applies. The chief difference being a higher resistance to false alarms, and slower response to aerosol test gas. Page 27

Tyco MX Virtual Detector M800 Series Identification Card


A convenient pocket sized Quick reference card designed to aid the identification of Tyco MX Virtual Detectors. Product Code AM2801/000 ID Card Note: Cards must be ordered in multiples of 100.

800 Series MX Detector Bases and Ancillaries


Features . 4 and 6 detector bases . Optional short circuit isolator in each base . Optional relay bases . Loop powered sounder bases . Remote indication LEDs . Standard and stainless steel duct probes . Optional conduit entry backboxes . Detector locking pins . Protective wire cages The 800 Series of MX VIRTUAL low profile detectors provide a comprehensive range of highly effective and aesthetically pleasing fire, smoke and heat detectors with worldwide approvals. The unique design and leading edge technology of the 800 Series MX low profile detectors goes beyond the detection technology itself. The range of detector bases is designed to make low profile detector installations cost effective, aesthetically pleasing and easy to install and maintain thus minimising disruption. The detector bases include standard universal bases, which have no integral electronics, thus making them low cost and low maintenance. Alternatively, a range of functional bases incorporates sounders, relays and line isolators to provide a cost effective method of adding functions and flexibility to the fire detection installation. Duct probe units are specially designed to enable optimum performance even at low air velocity and are also available in stainless steel.

Standard Universal Bases


The standard universal detector bases are compatible with new 800 Series MX detectors as well as the M600 and M900 Series low profile detectors. The standard bases have no electronics and even when the detectors are connected to the bases, they can be electrically disconnected and left in a park position. This enables wiring integrity tests to take place without any damage to electronics. When used with 800 Series MX VIRTUAL detectors the address flag automatically transfers to the base, thus the address remains with the base even if the detector is changed or replaced. An optional, tool removable locking pin allows the detector to be fixed in place to prevent tampering.

Minerva Universal Base (MUB)


This is the most common base designed to fix directly to the ceiling or various common backboxes including the 800EM for 18 and 21mm conduit entry and the DHM69 sealed deck head mount. This base allows a detector to be plugged in directly or a functional base to be plugged in between the base and detector. Features . Variety of fixing options . Remote LED connections . Anti-tamper facility . Park position and address flag holder Product Codes 517.050.001 MUB standard 4 base (UK/Marine) 571.070 MUB standard 4 base (EUROPE)

801IB - 4 Isolator Base


circuit isolation. Implemented on every detector the 801IB can ensure that no detector is lost on a system in the event of an open or short circuit. Alternatively the 801IB can be implemented between zones to provide short circuit isolation according to BS5839:Pt.1 and EN54. The 801IB can be used as a stand-alone line isolator fitted between callpoints and other ancillaries. Features . All the features of MUB . Up to 250 per MX DIGITAL loop (refer to technical publications for design parameters) . Isolation upstream and downstream Product Codes 516.800.903 801IB isolator base (UK/Marine) 572.033 801IB isolator base (EUROPE) (Consult technical publications for details and number of devices between isolators.)

With all the features of the MUB the 801IB isolator base allows any or all 800 Series MX detectors to be upgraded to incorporate bi-directional short

Page 28

6B - 6 Universal Base
Especially designed for applications using the US style single gang backbox the 6 base provides an attractive styled alternative to the 4 base in most applications. The 6 base is particularly useful for retrofit applications where large holes left by previous installations cannot be covered by the 4 base. Features . Waterproof gland protects the detector from water ingress from the rear . Remote LED connections . Anti-tamper facility . Includes blanking pieces for mounting holes Product Codes 517.050.606 6B-6 detector base (UL)

Functional Detector Bases


Functional detector bases use a common moulding which incorporates a double sided circuit board which enables electrical connections to be made on the top and bottom of the functional base. This allows the functional bases to be retrofitted into new and existing universal bases or alternatively using the functional base instead of the universal base can reduce the depth and cost of the installed detector. This feature enables additional sounders to be easily added during commissioning. In addition changes to the building during its life can be easily adapted to, by retrofitting sounders and relay outputs to existing detection points.

801SB Loop Powered Addressable Sounder Base


panel. This allows the 801SB to sound when its own detector is in alarm or as a zonal sounder. The number of 801SB per loop depends on the volume and loop power available. Features . 3 selectable tones (slow , fast and continuous) . 3 volume settings (90, 80 and 70dB effective) . single point sound source . standard MINERVA frequency . complies to prEN54:pt.3 . Loop current consumption at full volume 15mA . 24V Current consumption at full volume 25mA Product Codes UK EUROPE 516.800.907 572.029 801SB loop power sounder base Note: For detailed design guidelines on loop powering ensure that Technical Publications are consulted.

The 801SB sounder base operates with all 800 Series MX VIRTUAL detectors. A unique design single point sound source is used to provide complete audio coverage without obtrusive holes in the moulding. The 801SB is controlled by the powerful event action of the MX fire detection

Tyco MKII Sounder Bases


A new low current range of sounder bases for use with the MX Fire Alarm Control Panel. Features Manufactured to EN54 part 3 Integral sounder and detector base Volume and tone adjustable after installation Low Power Synchronisation Do not require use of a standard base (maybe installed directly onto a standard besa box) Product Code 516.800.910 802SB MX Loop Powered Sounder Base 516.800.913 812SB Loop Powered UL Sounder Base 516.800.911 901SB Universal Sounder Base 516.800.912 912SB Universal UL Sounder Base

Please See Following Applications Table for Further Details.

SAM 800 Sounder Addressable Module


The SAM 800 Sounder Addressable Module is an MX addressable device which may be fitted to the 801SB, 802SB, 812SB, 901SB and 912SB Sounder Bases to enable the MX Control Panel to communicate with and control these sounder bases, without the need for a detector effectively turning the 801SB, 802SB, 812SB, 901SB and 912SB into an addressable loop powered sounder. The SAM 800 is suitable for wall or ceiling mounting. Sound selection and tones will be as per the 801SB, 802SB, 812SB, 901SB and 912SB. Product Code 516.800.954 SAM 800 Sounder Addressable Module (compatible with Version 2.1 and above)

Page 29

SAB 800 Sounder Addressable Beacon


The SAB 800 Sounder Addressable Beacon is an MX Addressable Beacon that fits into the Standard Minerva Universal Base. Alternatively the SAB 800 may be fitted to the 801SB, 802SB, 812SB, 901SB and 912SB Sounder Bases to enable the MX Control Panel to communicate with and control these sounder bases and also provide a Flashing Beacon effectively turning the 801SB, 802SB, 812SB, 901SB and 912SB into a combined addressable loop powered sounder and beacon. The SAB 800 is suitable for wall or ceiling mounting. Sound selection and tones will be as per the 801SB, 802SB, 812SB, 901SB and 912SB. Product Codes 516.800.953 SAB 800 Sounder Addressable Beacon (compatible with Version 2.1 and above available December 2002)

801RB - Functional Relay Base


The 801RB provides dual relay contacts for signalling external devices on MX addressable systems. A very low operating current even when the relay is energised enables the relay base to be used without any additional power. The dual contacts are under the control of a programmable output, through the powerful cause and effect software. Features . Dual pole 24V DC relay contacts (60VA) . Status indication LED . Very low power consumption (<20A except startup) Product Codes UK 516.800.905 801RB Relay base

EUROPE 572.028

Volume Adjustment Tool


A simple Volume Adjustment Tool, specific to the task of sounder volume selection on the variablevolume range of Tyco MKII Sounder Base Devices. Sounder volume can be easily varied between the maximum 90dBA and minimum 68dBA-volume settings, using this simple, functional tool. Note: Sounder Base Devices are supplied with the volume pre-set to maximum volume. Product Code 517.050.015 Volume Adjustment Tool

Detector Ancillaries
800 Series MX Address Flag
The 800 Series detectors incorporate a feature, which automatically transfers the address flag to the detector base, when the detector is plugged into the base. On removal of the detector the address flag remains on the ceiling, thus ensuring that detectors are not accidentally returned to the wrong detector base following service routines. Most MX detection panels incorporate additional fail safe software features to ensure that incorrect detector positioning does not compromise the system. Address flags are supplied in packs of 100. Labels are provided on sheets of 250 in four colours to enable quick identification between different loops. Product Codes 516.800.915 MXAddress flags (pack of 100) 516.800.931 Address flag labels Loop A - White 516.800.932 Address flag labels Loop B - Yellow 516.800.933 Address flag labels Loop C - Purple 516.800.934 Address flag labels Loop D - Green

Page 30

Tyco MKII Sounder Base Range Identification Card

A convenient pocket sized quick reference card designed to aid the identification of the Tyco MKII Sounder Base Range. This concise card provides a simple, effective reference key for rapid identification of sounder base type during the initial visual system analysis and needs assessment.

Product Code 517.050.016 ID Cards Note: Cards must be ordered in multiples of 100.

Page 31

MKII Sounder Base Applications Table

Page 32

800 Series Detector Locking Pins


Supplied in packs of 100 the detector locking pins allow 800 Series MX detectors to be locked to universal or functional bases to prevent them from being accidentally or maliciously removed or swapped around. Product Codes UK EUROPE 517.050.005 571.071 Pack of 100 detector locking pins

801RIL - Remote Indication LED


All detector bases have the ability to drive a remote LED in the event that the installed position of the detector is not easily visible. The 801RIL is primarily designed for LPCB influenced markets but is compatible with all 800 Series detectors. Features . UK Single gang mounting . High intensity red LED Product Code 516.800.908 801RIL remote indication LED

800HL - Indication Lamp


The 800HL remote indicator lamp provides a larger indicator for use in place of the RIL when longer distances are involved or in VdS influenced markets. Typically used to indicate the source of an alarm in buildings with long corridors eg. Hotels, hospitals, apartments. Product Codes UK EUROPE 516.800.909 572.000 800HL indication lamp

800EM - Euro Mounting


The euro-mounting base provides a matching back box, which allows the standard MUB, and 801IB to be ceiling mounted with conduit entries for standard 18 and 21mm conduit. Features . 2 x 18mm conduit entries . 2 x 21mm conduit entries . Fits MUB & 801IB bases Product Codes UK EUROPE 516.800.921 572.031 800EM mounting base

DHM69 - Deck Head Mounting


Where 800 Series MX detectors are mounted in humid and environmentally challenging situations such as Marine or offshore installations the DHM69 deck head mount provides a sealed waterproof mounting which protects all electrical connections. Features . 4 x 20mm gland entries . Fits MUB and 801IB bases Product Code 517.001.231 DHM69 deckhead mounting

W500 - Protective Detector Cage


The W500 is a strong white powder coated steel cage designed to fit around 800 Series detectors fitted with universal or functional bases. Features . White powder coat finish . Small mesh Technical Specification Dimensions: 125 Dia x 85H mm Weight: 161g Product Code 517.050.011 W500 detector cage

Page 33

Detector Housings
MP69 - Standard EN54 Duct Probe Unit
The MP69 is a tough fire resistant plastic enclosure incorporating an MUB universal detector base for use with 801PH optical detectors. A clear polycarbonate cover allows the detector and alarm LED to be easily viewed. An internal baffle and precisely designed inlet and exhaust tubes provide maximum sensitivity at very low air velocities. Features . Probe tubes available from 450 to 1500mm (Minimum 200mm) . Suitable for air speeds from 1.5 to 25m/s (4.9 to 82 feet/second) . Optimised for fast response to smoke particles . Easy access for detector servicing Product Codes UK EUROPE 517.025.036 572.001 MP69 duct probe 517.001.035 DP450 mm probe tube and exhaust 517.001.036 DP600 mm probe tube and exhaust 517.001.037 DP750 mm probe tube and exhaust 517.001.038 DP900 mm probe tube and exhaust 517.001.039 DP1200 mm probe tube and exhaust 517.001.040 DP1500 mm probe tube and exhaust

SMP69 - Stainless Steel Duct Probe Unit


The SMP69 is a stainless steel duct probe unit with the same features as the MP69 duct probe. Features . Stainless steel 316 body and probe tubes . Probe tubes available from 450 to 1500 mm (Minimum 200mm) . Suitable for air speeds from 1.5 to 25m/s (4.9 to 82 feet/second) . Optimised for fast response to smoke particles . Easy access for detector servicing Product Codes UK EUROPE 517.025.035 572.002 SMP69 stainless steel duct probe 517.025.028 DPS450 mm probe tube and exhaust 517.025.029 DPS600 mm probe tube and exhaust 517.025.030 DPS750 mm probe tube and exhaust 517.025.031 DPS900 mm probe tube and exhaust 517.025.033 DPS1500 mm probe tube and exhaust

Detector Ancillary Technical Specifications


Model MUB 801IB 6B 801RB 812RB 801SB 800EM DHM69 800SA 800HL 801RIL MP69 SMP69 Height mm 10 10 21 36 36 36 85 40.5 22 85 22.5 90 90 Width mm 108 108 152 108 108 108 125 145.5 109 85 85.5 145 150 Length mm NA NA NA NA NA NA 125 145.5 NA 38 85.5 220 226 Weight gms 70 70 120 152 152 166 TBA 184 50 65 50 580 1200 Material Bayblend Bayblend Bayblend Bayblend Bayblend Bayblend Bayblend Bayblend Bayblend Polycarbonate Polycarbonate Polycarbonate SS316 & Polycarbonate Colour White White White White White White White White White White White White S/Steel Power NA 80A max NA 20A 20A 0.5-1lpu# NA NA NA 200A Max 8.23mA Max NA NA Temp.
oC

-25 to +90 -25 to +70 -25 to +90 -25 to +70 -25 to +70 -25 to +70 -25 to +90 -25 to +90 -25 to +70 -25 to +70 -25 to +70 -20 to +70 -20 to +70

Humidity %RH NA up to 95%RH up to 95%RH up to 95%RH up to 95%RH up to 95%RH NA NA NA up to 95%RH up to 95%RH up to 95%RH up to 95%RH

# 1lpu (Loop Power Unit) = 15mA Loop Current or 25mA @ 24Vd.c. for Battery Calculations

Page 34

Aspirating Smoke Detectors VESDA - Vision Systems VLC 800 MX VESDA Laser COMPACTTM
premium. This has been achieved through the combination of approved LaserPLUS detection technology, dual stage filtration technology and a modified aspirator design incorporated in a smaller enclosure with simplified display. The VLC 800 MX VESDA Laser COMPACT is available with an inbuilt MX interface to enable it to communicate directly with the MX loop. Connects directly onto MX Loop Provides Analogue Value at MX controller Technical Specification Supply Voltage: Current Consumption:

18 to 30Vd.c. 225mA quiescent, 245mA in alarm

The VLC 800 MX VESDA Laser COMPACT TM detector has been specifically designed to provide all the benefits of aspirating smoke detection, including very early warning, in single small environment areas and where space is a

Features Reduced size Absolute smoke detection Wide sensitivity range Single pipe inlet Simple display c/w service LED Dual stage dust filter Air flow monitoring Simple mounting design AutoLearnTM

Dimensions: Weight: Operating Temp.: Sampled Air:

225H x 225W x 85Dmm 1.9Kg -10o C to+ 39oC -20o C to +60 oC

Product Codes 516.018.012 VLC 800 MX Addressable Vesda Laser Compact (compatible with Version 2.1 and above)

MX Ancillaries
Callpoints & Pullstations - CP820 Indoor Callpoint
Technical Specification Meets BS5839 Pt.2 and pr EN54 Pt:11 EMC/RFI: Equal or exceeds EN500811 & EN50082-1 Operating Temp.: -20 to +70oC Relative Humidity: up to 95% RH noncondensing Dimensions: 87H x 87W x 51(19mm flush mount)D mm Weight: 200g Quiescent Current: 0.25mA Alarm Current: 2.5mA Ident. Value: 129 The CP820 is an indoor MX addressable manual callpoint with programmable status LED. The CP820 is designed for LPCB approvals and the CP820M for Marine approvals. The CP820 provides high speed communication to the MX panel of a manual fire alarm. Product Codes 514.800.503.T CP820 Indoor Callpoint (English Thorn Branded) 514.800.503.A CP820 Indoor Callpoint (English ADT Branded) 514.800.503.Y CP820 Indoor Callpoint (English TYCO Branded) 552.006 CP820 Indoor Callpoint (International) 514.800.511.T Thorn KAC Indoor Callpoint (Dutch) 552.004 Zettler KAC indoor Callpoint (Dutch) 514.800.505.T CP820M Marine Indoor Call Point (Thorn)

Callpoints & Pullstations - CP830 Outdoor Callpoint


CP830M for Marine approvals. The CP830 provides high speed communication to the MX panel of a manual fire alarm. Technical Specification Meets BS5839 Pt.2 and pr EN54 Pt:11 EMC/RFI: Equal or exceeds EN500811 & EN50082-1 Operating Temp.: -20 to +70 oC Relative Humidity: up to 95% RH noncondensing Dimensions: 135H x 135W x 30D mm Weight: 200g Quiescent Current: 0.25mA Alarm Current: 2.5mA Ident. Value: 130 Product Codes 514.800.504.T CP830 Outdoor Callpoint (English Thorn Branded) 514.800.504.A CP830 Outdoor Callpoint (English ADT Branded) 514.800.504.Y CP830 Outdoor Callpoint (English TYCO Branded) 552.007 CP830 Outdoor Callpoint (International) 552.005 Zettler KAC Outdoor Callpoint (Dutch) 514.800.512.T Thorn KAC Outdoor Callpoint (Dutch) 514.800.506.T CP830M Marine Outdoor Callpoint (Thorn)

The CP830 is an outdoor MX addressable manual callpoint with programmable status LED. The CP830 is designed for LPCB approvals and the

Page 35

STOPPER
The callpoint STOPPER provides protection from malicious or accidental activation of manual callpoints. Available for flush or surface mounted callpoints the STOPPER is also available with optional high pitch sounder which is activated when the lid is lifted. An optional Break-Seal fitting kit allows BreakSeals to be used to provide extra protection. WARNING:-Break seals only to be fitted by agreement with relevant fire authorities. The STOPPER is suitable for all callpoints up to 100mm square, including CP820, CP920, CP200 and other indoor KAC style callpoints.

Product Code 515.001.033 IPO36 Break Seal Kit With Sounder Weatherproof

Product Code 515.001.029 515.001.030 515.001.036 515.001.034 515.001.035 515.001.031 515.001.032

Ref STI6530 STI6531 STI6535 STI1230 STI3150 STI6532 STI6533

STOPPER Flush Surface

STOPPER II

4 STOPPER Dimensions

Millimetres A B C D E F G H

137 140 104 45 12.5 12.5 185 12.5

Flush Fit Stopper Stopper with Sounder STI6530 STI6532

Surface Fit
(+30mm)

STI6531 STI6533

STOPPER II Dimensions

STOPPER STOPPER II Max. Callpoint Size 100 x 100mm 160 x 160 mm Max. Callpoint Depth 57.5 120 (+30mm Surface)

Stopper II Surface Fit - STI1230 Page 36

Millimetres A B C D E F G H

70 16 197 50 178 146 228 254

STOPPER II
STOPPERIIis constructed as the STOPPER from tough injection moulded polycarbonate. Physically larger than the STOPPER the STOPPER II extends the number of products to which these tough multi-purpose covers can protect. It consists of a strong tamper-proof clear polycarbonate cover and frame that fits easily over such products as break glass callpoints. The STOPPER II can also be fitted with an integral battery powered sounder which activates if the cover is lifted. The STOPPER II is suitable for callpoints up to 160mm square like the DIN820/830 and CP830. Product Code 515.001.034 STI1230 Surface fit STOPPERII

Weather STOPPER & Weather STOPPER

II

The Weather STOPPER and Weather STOPPERII extends the life of weather exposed devices, such as break glass callpoints, by offering protection against harsh conditions and environments. Experience has shown that this protective cover can extend the life of products installed in saline atmospheres, such as oil rigs and ship decks. While offering environmental protection the Weather STOPPER and Weather STOPPER IIare constructed from tough durable polycarbonate which will also guard against tampering, vandalism or accidental operation of devices such as emergency switches. Product Codes 515.001.036 STI6535 Surface fit Weather STOPPER 515.001.035 STI3150 Surface fit Weather STOPPER II

Callpoint Ancillaries

Product Code 515.001.028 Callpoint hinged cover for use on CP820 models

Product Codes 515.001.021 Standard Red surface mounting back box for CP820 callpoints

Product Code 90-107 Red M141 spacer for red CP820 KAC callpoints

Spare Test Keys Product Codes 90-106 Test keys for all KAC callpoints

Product Codes 515.001.025 CP820/830 Glasses, clear English text on white background. No logo (pack 5). Fitted as standard to English CP820/830 Callpoints

Product Code 515.001.026 Black callpoint bezel for CP820

Page 37

MX Addressable Input/Output Modules


Tyco MX TECHNOLOGY provides a large range of addressable ancillary devices which can be programmed and tested with the MX SERVICE tool. The first group of modules to be made available is shown in detail in this section. Other modules including intrinsically safe devices, multiple input/output devices, emergency telephone and the MX addressable voice evacuation amplifiers and ancillaries will follow later.

APM800 Addressable Power Supply Monitor


The APM800 is an MX addressable power supply monitoring module which is usually used with the PSM800 power supply module to make an addressable power supply. The APM800 is designed to fix to studs on the top of the PSM800. The APM800 monitors the PSM800 for mains failure, earth fault, battery charger fault and battery fault. It can reset the PSM800 resettable 24Vd.c. output and initiate a battery test which then reports battery voltage and current to the controller. Technical Specification EMC/RFI: Equal or exceeds EN500811 & EN50130-4 Operating Temp.: -20 oC to +70 oC Relative Humidity: up to 95% RH noncondensing Dimensions: Weight: Quiescent Current: 24H x 127W x 57D mm 0.794Kg 0.1mA (APM800 - 1 from loop) 0.3mA (from PSU) 0.1mA (APM800 - 1 from loop) 0.3mA (from PSU) 162

Alarm Current:

Ident. Value: Product Codes 557.202.027 APM800 addressable power supply monitor (UK) 572.018 APM800 addressable power supply monitor (EUROPE)

MIM800 Mini-Input Module (E)


The MIM800 is a small MX addressable module designed for monitoring a single input circuit. The MIM800 can monitor normally open or normally closed inputs and provides open and short circuit monitoring of the line. The MIM800 is designed for fitting in small devices such as flow switches, special detection devices and explosion proof callpoints. A variant of the MIM800 is used in all callpoints and pullstations. Technical Specification EMC/RFI: Equal or exceeds EN500811 & EN50130-4 Operating Temp.: -20 oC to +70 oC Relative Humidity: up to 95% RH noncondensing Dimensions: Weight: Quiescent Current: Alarm Current: 13H x 48W x 57D mm 100g 0.25mA 0.25mA (without LED) 2.5mA (with LED) 200 Ohm 100 Ohm 128

EOL resistor: Monitor Resistor: Ident. Value: Product Codes 555.800.001 MIM800 mini-input module (UK) 572.016 MIM800 (E) mini-input module (EUROPE)

CIM800 Contact Input Module (EK)


The CIM800 is a flexible addressable inputmonitoring device that fits in the standard ancillary housings. The CIM800 provides a single input to current MX panels though this can be implemented as two separately wired spurs (Style B) or as a loop (Style A). Both spur and loop input wiring can be configured to monitor normally open or normally closed inputs. In addition both can be configured to initiate an alarm or short circuit fault message in the event of a short circuit on normally open monitoring circuits. Technical Specification EMC/RFI: Equal or exceeds EN500811 & EN50130-4 Operating Temp.: -20 oC to +70 oC Relative Humidity: up to 95% RH noncondensing Dimensions: 14H x 148W x 87D mm Weight: 100g Quiescent Current: 300A Alarm Current: 3mA EOL & monitor resistor: 10k Ohms Ident. Value: 145 Product Codes 555.800.002 CIM800 contact input monitor (UK) 572.017 CIM800 (EK) contact input monitor (EUROPE) 555.800.032 CIM 800 Module c/w Front Cover (UK) 572.020 CIM 800 Module in isolated D800 housing (EUROPE)

DIM800 Detector Input Module (ADK)


an external 24V d.c. supply and is reset by the MX addressable panel. The DIM800 monitors the external 24V d.c. and provides a fault signal if it is lost. The input detection circuit can be wired as one or two spur circuits (Class B), one loop configured circuit (Class A) or one 4 wire detection circuit. The DIM800 is designed to be compatible with most conventional detection products. Compatibility has been tested to date on the following products: Compatible Thorn detectors: M300 Series , M601 Series , S100 Series, H Series, S231F, S231F+, CP200 Compatible Zettler detectors: M613 Series. The DIM800 is designed to power and monitor a circuit of low voltage conventional detectors and callpoints. The detection circuit is powered from Page 38 Technical Specification EMC/RFI: Equal or exceeds EN500811 & EN50130-4 Operating Temp.: -20o C to +70o C Relative Humidity: up to 95% RH noncondensing Dimensions: 14H x 148W x 87D mm Weight: 100g Quiescent Current: 0.1mA (from loop) 7.5mA (from ext. supply) Alarm Current: 0.1mA (from loop) 50mA (from ext. supply) Ident. Value: 145 Product Codes 555.800.012 DIM800 detector input monitor (UK) 562.011 DIM800 (ADK) detector input monitor (EUROPE) 555.800.042 DIM 800 Module c/w front cover (UK) 562.012 DIM800 Module in isolated D800 housing (EUROPE)

RIM800 Relay Interface Module (AN)


The RIM800 provides a single programmable relay output from the MX DIGITAL addressable loop which can be programmed for a variety of applications including signalling fire conditions to plant, machinery, fire doors, dampers & security systems. The RIM800 relay coil is monitored. The RIM800 relay contact is rated for 2A @ 24V d.c. but can be used to switch mains voltage when used with the HVR800. This unit has two optoisolated terminals specifically for driving the HVR800. Technical Specification EMC/RFI: Equal or exceeds EN500811 & EN50130-4 Operating Temp.: -20o C to +70o C Relative Humidity: up to 95% RH noncondensing Dimensions: 14H x 148W x 87D mm Weight: 100g Quiescent Current: 200A Alarm Current: 3mA Relay contacts: 2A @ 24V d.c. Ident. Value: 161 Product Codes 568.800.003 RIM800 relay interface module (UK) 572.007 RIM800 (AN) relay interface module (EUROPE) 568.800.033 RIM 800 Module C/W Front Cover (UK) 572.021 RIM800 Module in isolated D800 housing (EUROPE)

HVR800 High Voltage Relay Module (NSE)


The HVR800 module is a non-addressable device which allows a low current mains rated relay to switch up to 10A. Alternatively a low voltage drive signal such as that provided by the RIM800 or 80 way mimic can be used to switch the integral mains relay via the opto-isolated input. Technical Specification EMC/RFI: Equal or exceeds EN500811 & EN50130-4 Operating Temp.: -20oC to +70 oC Relative Humidity: up to 95% RH noncondensing Dimensions: 26.5H x 42W x 74D mm Relay Contacts: Up to 10A @ 250Va.c. Product Codes 568.800.004 HVR800 OEM high voltage relay (UK) 568.800.034 HVR800 in isolated D 800 housing (UK) 572.008 HVR800 (NSE) high voltage relay (EUROPE) 572.022 HVR800 in isolated D800 housing (EUROPE)

SNM800 Sounder Notification Module (A)


The SNM800 is a remote addressable sounder circuit output device capable of switching sounder and speaker circuits up to 2A @ 24V d.c. or provide a monitored output facility for other applications. These can be used in addition to the two circuits provided as standard on most MX detection panels. The SNM800 can support sounder circuits wired as a spur (Class B Style Y) or in a loop configuration (Class A Style Z). The SNM800 can be configured with a RIM800 to provide a secure monitored extinguishing release solenoid control. Technical Specification EMC/RFI: Equal or exceeds EN500811 & EN50130-4 Operating Temp.: -20oC to +70 o C Relative Humidity: up to 95% RH noncondensing Dimensions: 14H x 148W x 87D mm Weight: 100g Quiescent Current: 0.5mA Alarm Current: 3mA Output rating: 2A @ 24V d.c. EOL resistor: 27k 1/2W Ident. Value: 177 Product Codes 577.800.005 SNM800 sounder notification module (UK) 572.009 SNM800 (A) sounder notification module (EUROPE) 577.800.035 SNM800 Module c/w Front cover (UK) 572.023 SNM800 Module isolated D800 housing (EUROPE)

LPS800 Loop Powered Sounder Module


output circuit with up to 75mA of power sourced from the MX panel. Technical Specification EMC/RFI: Equal or exceeds EN500811 & EN50130-4 Operating Temp.: -20oC to +70 oC Relative Humidity: up to 95% RH noncondensing Dimensions: 14H x 148W x 87D mm Weight: 100g Quiescent Current: 0.93mA Alarm Current: Up to 75mA continuous Output rating: 120mA @ 24V d.c. max Ident. Value: 178 Product Codes 577.800.011 LPS800 Loop Powered Sounder module (UK) 572.014 LPS800 Loop Powered Sounder module (EUROPE) 577.800.041 LPS800 Module c/w front cover (UK) 572.027 LPS800 Module in isolated D800 housing (EUROPE)
NOTE: Each MX Digital Loop can provide up to 495mA for LPS800, 801SB AND 802SB.

The LPS800 provides a single monitored sounder

SB520 Sounder Booster Module


SNM800 to drive circuits with higher currents whilst maintaining the reverse polarity integrity line monitoring. Technical Specification EMC/RFI: Equal or exceeds EN500811 & EN50130-4 Operating Temp.: -20o C to +70o C Relative Humidity: up to 95% RH noncondensing Dimensions: 14H x 148W x 87D mm Weight: 100g Output rating: 15A @ 24V d.c./10A Max. per terminal Ident. Value: Non addressable Product Codes 577.001.023 SB520 Sounder Booster Module (UK) 572.012 SB520 Sounder Booster Module (EUROPE) 577.001.033 SB520 Module c/w Front Cover (UK) 572.024 SB520 Module in isolated D800 housing (EUROPE) Page 39

The SB520 sounder booster module enables the

LI800 Line Isolator Module


section whilst allowing the rest of the addressable loop to function normally. The LI800 Ancillary Line Isolator Module ensures that on a looped addressable system a short circuit fault cannot disable more detection devices than would be lost on a conventional non-addressable system in accordance with BS5839 Part 1. Technical Specification EMC/RFI: Equal or exceeds EN50081-1 & EN50130-4 Operating Temperature: -25C to +70C Relative Humidity: Up to 95% RH non-condensing Dimensions: 14H x 148W x 87D mm Weight: 100g Battery Requirements: Standby 160A Max Tripped One short circuit less than 2.5mA, Two short circuits less than 3.6mA. Product Codes 545.800.001 LI800 Ancillary Line Isolator Module (UK) 572.019 LI800 Ancillary Line Isolator Module (EUROPE) 545.800.031 LI800 Ancillary Line Isolator Module c/w front cover (UK) 572.026 LI800 Ancillary Line Isolator Module in Isolated D800 Housing (EUROPE)

The LI800 Ancillary Line Isolator Module is designed to be used on all MX addressable loops. It monitors the line condition and upon detection of a short circuit it isolates the affected

TM520 Timer Module


The TM520 provides an output that can be activated based on a delay time. If either the keyswitch on the module is activated, or a predefined event within the control panel occurs then a timed delay (set between 10 minutes and 2 hours 10 minutes) is started. When the delay reaches zero the TM520 output is activated. The unit sounds an internal buzzer and shows a red LED when the output is active, and shows a yellow LED when the timer is counting down. To provide a warning that the delay is nearly over, the red LED and the buzzer will pulse 5 minutes before the end of the delay . The TM520 requires a separate 24V DC supply to operate. The module is not addressable and will therefore not take an address on the loop. Technical Specification Powered: 24Vd.c. Temperature Range: -10o C to +70o C Operating Humidity: >95% RH Dimensions: 87H x148W x 14D mm Product Codes 557.180.423 TM520 timer module - non addressable

LAV800 VdS Extinguishing Interface


The LAV800 provides an MX addressable standard VdS extinguishing interface in a standard MX ancillary size package. Technical Specification EMC/RFI: Equal or exceeds EN500811 & EN50130-4 Operating Temp.: -20o C to +70oC Relative Humidity: up to 95% RH noncondensing Dimensions: 14H x 148W x 87D mm Weight: 100g Quiescent Current: 300A Alarm Current: 3mA Ident. Value: 180 Product Codes 572.015 LAV800 VdS extinguishing interface (EUROPE) 572.025 LAV800 Module in isolated D800 housing (EUROPE)

SIO800 Single Input/Output Module


Controller. The LED may be turned ON or OFF by the controller during a relay activated condition. Product Codes 555.800.063 SIO800 Single Input/Output Module (compatible with Version 2.1 and above) 555.800.064 SIO800 Single Input/Output Module c/w Front Cover (compatible with Version 2.1 and above)

The SIO800 single Input/Output Module is designed to provide a monitored input and a volt free relay changeover output. It consists of an input for monitoring the status of a normally open contact and output of changeover relay contacts The relay is controlled by a command sent from the Minerva MX Fire Controller via the addressable loop. The state of the relay (activated,deactivated or stuck) is reported to the Minerva MX Fire

Technical Specification EMC/RFI: Product Family standard EN50130-4 in respect of Conducted Disturbances, Radiated Immunity, Electrostatic Discharge, Fast Transients and Slow High Energy. EN50081-1 for Emissions. Operating Temperature: -25C to + 70 C Relative Humidity: Up to 95% RH non-condensing Dimensions: 14H x 148W x 87D mm Weight: 105g Quiescent Current: 0.3mA Alarm Current: 3mA EOL Resister: 3k3 Ident Value: 148

Page 40

DIO 800 Dual Input/Output Module


The DIO800 provides two monitored detector circuits and two 24V outputs on a single board. The unit is supplied as a chassis mount for incorporation into any suitable enclosure such as the ANC-3 housing or complete with its own enclosure. The unit requires a 24 V power supply and each of the two class B detection circuits can drive up to 20 of the 600 series conventional detectors.Each input has an associated 24V output with the same address. Only two addresses are required for the unit programmed via the 801AP address-programming tool . MXConsys is used to assign a functional group to an input point, commands are then sent to this group to control the appropriate output. Two LEDs indicate the status of the two inputs. Technical Specification Operating Temperature: -20 C to + 70C Relative Humidity: Up to 95% RH Non-Condensing Dimensions: 74mm H x 101mm W x 25.6mm D (with housing) Weight: 136g Quiescent Current: External 8.0mA, Loop 0.28mA Alarm Current: External 80mA, Loop 0.28mA EOL Resistor: 10K ohm Outputs: 2 x 200A @ 24Vdc Ident Value: 193 Product Codes 555.800.062 DIO 800 Dual Input/Output Module c/w Enclosure (compatible with Version 2.1 and above). 555.800.022 DIO 800 Dual Input/Output Module (compatible with Version 2.1 and above)

Page 41

MX Ancillary Housings
MX Ancillary Housings
A variety of ancillary housings are available to fit the 800 Series MX ancillaries. The standard sized modules are mechanically compatible with all options. LPCB approvals are with the M800 double gang cover plate or ancillary housings. VdS certification is with the Zettler ancillary box and ancillary housings. The M520 double gang cover provides external access for the MX SERVICE TOOL to plug into the ancillary module which is mounted in the cover. All options allow the ancillary to be programmed and tested when the cover is removed.

517.035.007 M520 Ancillary cover for use with 800 modules

557.201.401 D800 IP65 ancillary housing

572.004

517.035.011
K2214 ALM Metal surface mount MK backbox for use with M520 or 800 Series addressable ancillaries using 517.035.007 cover. Includes 7 x 20mm knockouts.

517.035.010 MK K2142 White plastic surface mount MK backbox for use with M520 or 800 Series addressable ancillaries using 517.035.007 cover.

517.035.014 8621C Steel flush mount MK backbox for use with M520 or 800 Series addressable ancillaries using 517.035.007 cover with knockouts.

Product Code 517.035.011 517.035.010 517.035.014 517.035.015

MKRef Mounting K2214 Surface K2142 Surface MK862/KFlush QFB/2 Flush/ Dry Lining

Dimensions 146x86x40mm 146x86x34mm 132x72x26mm 146x85x38mm

Knockouts 1x20mm rear/7x20mm sides One rear (25x35mm) 4x20mm rear/12x20mm sides 2 top & bottom

Earth Screw Yes N/A Yes N/A

Material Steel Plastic Steel Plastic

517.035.015 QFB/2 Dry lining flush mount (for plasterboard etc) MK backbox for use with M520 or 800 Series addressable ancillaries using 517.035.007 cover.

ANC-3 & ANC-8 Ancillary Housing


Most addressable modules can be fitted into a double gang MK style backbox using the M520 ancillary cover. Where several devices are mounted in one place the ANC3 houses 3 x modules and the ANC8 houses 8 modules, expandable to 16 using the STK8 stacking kit.

ANC-3 Ancillary Housing


Product Codes 557.180.097.A ANC-3 MINERVA ancillary housing - for use with M800 ancillary modules (can accommodate up to 3 M800 modules) ADT Branded 557.180.097.T ANC-3 MINERVA ancillary housing - for use with M800 ancillary modules (can accommodate up to 3 M800 modules) Thorn Branded 557.180.097.Y ANC-3 MINERVA ancillary housing - for use with M800 ancillary modules (can accommodate up to 3 M800 modules)

Page 42

ANC-8 Ancillary Housing


Product Codes UK EUROPE 557.180.096.A ANC-8 MINERVA ancillary housing - for use with X800 ancillary modules (can accommodate up to 16 X800 modules with stacking kit) ADT Branded 557.180.096.T ANC-8 MINERVA ancillary housing - for use with X800 ancillary modules (can accommodate up to 16 X800 modules with stacking kit) Thorn Branded 557.180.096.Y 572.034 ANC-8 MINERVA ancillary housing - for use with X800 ancillary modules (can accommodate up to 16 X800 modules with stacking kit) 557.180.095 572.036 STK-8 MINERVA ancillary stacking kit for use with ANC-8 ancillary housing

Callpoint & Ancillary Address Labels


Product Codes Zone Labels 599.047.011 Zone labels - Zones 1 - 16 599.047.012 Zone labels - Zones 17 - 32 599.047.013 Zone labels - Zones 33 - 48 599.047.014 Zone labels - Zones 49 - 64 599.047.015 Zone labels - Zones 65 - 80 599.047.016 Zone labels - Zones 81 - 100 599.047.018 Zone labels - Zones 101 - 120 599.047.019 Zone labels - Zones 121 - 140 599.047.020 Zone labels - Zones 141 - 160 599.047.021 Zone labels - Zones 161 - 180 599.047.022 Zone labels - Zones 181 - 200 599.047.023 Zone labels - Zones 201 - 220 599.047.024 Zone labels - Zones 221 - 240 Address Labels 599.047.030 Address Labels 1 - 250 Loop A - White 599.047.031 Address Labels 1 - 250 Loop B - Yellow 599.047.032 Address Labels 1 - 250 Loop C - Purple 599.047.033 Address Labels 1 - 250 Loop D - Green

Detectors have a special address flag for carrying the address labels - details in the detector section. For other devices or on detectors where zone information is also required a series of address labels are available. Numbered 1 to 250 the address labels are available in 4 different colours to distinguish between different loops. In addition small zone labels can be fixed to the address labels.

Page 43

Programming and Service Tools


MX SERVICE Tool
Suitable for desktop or single handed operation the MX SERVICE tool is battery operated using standard rechargeable batteries. An accessory pack provides alternative straps, and cigarette lighter adaptor. Software Features include: . Read/write the detector/ancillary address . Display date of manufacture and commissioning . Display serial number . Display temperature/ CO levels / smoke obscuration . Programming of the LED . Testing the detector remote LED and control outputs . Perform the detector self verification test function . Displaying detector dirtiness level . Controlling ancillary outputs . Reading ancillary statuses . Power management options Product Codes 516.800.918 801AP MX SERVICE tool English 516.800.922 Spare ancillary programming lead - English 572.006 801AP MX SERVICE tool German 572.030 Spare ancillary programming lead- German 516.800.924 Pack of Spare Pins (Pk 10) 516.800.926 MX Service Tool PMS Dongle Parallel 516.800.928 AVRISP-02-MX PMS Programming Lead The MXService tool has a finite life time after which the software must be recharged by an MX authorised administrator.

The TYCO MX SERVICE tool is a powerful and flexible tool for assistance in the installation, commissioning, diagnostics and service of Tyco MX detection systems. The MX SERVICE tool allows all MX addressable devices to be interrogated, tested and programmed.

MX Service Accessory

Kit
A carry case which contains the following items:Car Lighter Adapter Shoulder Strap This provides space for the following:801AP MX Service Tool Ancillary Programming Lead Mains Charger Product Codes 516.800.923 MX SERVICE accessory kit - UK 572.032 MX SERVICE accessory kit - German

MX CONSYS
MX CONSYS is a powerful Windows 95 and 98 compatible programming tool which provides full system programming functions and project configuration and issue control. MX CONSYS is used on MINERVA MX, T2000, ZETTLER EXPERT and AUTOCALL MX panels. Features . Windows based . Programs the system across multiple subpanels . Downloads to the system from one point . Supports remote dial in capability . Provides software download as well as configuration download . Dongle protected . Provides full project configuration printouts It also supports automatic data transfer to MX GRAPH, graphical mimic and alarm management systems. MX CONSYS is available under document control from authorised personnel in the Tyco businesses. Product Codes UK EUROPE 557.203.001 MXCONSYS Dongle and license (parallel port) 557.202.118 542.011 MXCONSYS Download lead 557.203.003 MXCONSYS Dongle and license (USB)

MX REMOTE
MX REMOTE is a Windows based software tool for remote service and support and MX detection panels. MX REMOTE provides a full function fire panel repeater running on a PC either locally or over dial up telephone lines. Providing the operator has the correct passwords MX REMOTE allows all operator, manager, service and engineer functions available at the panel to be provided at the PC. This allows the customer or the Tyco service organisation to provide remote assistance, service and limited configuration assistance to the installation. MX REMOTE is available as a stand-alone software application for Tyco service operations. Alternatively TEPG are able to provide consultancy and assistance in implementing MX REMOTE as an integrated part of a central station and service centre system. Page 44 Product Codes 557.203.002 MXRemote dongle and license (parallel) 557.203.004 MXRemote Dongle and license (USB) 557.202.036 MXRemote modem (BABT) 542.036 24Vd.c. MX Remote Modem (EU)

MX DEMO CASE
An MX Panel, 801CH Detector, 801PH Detector, LEDs and Switches mounted in a carry case and pre-configured with demo software.

Product Code 557.200.901

SOLO Detector Service Equipment

Product Codes 517.001.224 SOLO704 Adaptor tube B - Adapts SOLO100/101 pole sets for TYCO detector changers and testers 517.001.230 SOLO100 Telescopic extension pole 1.26M to 4.5M long 517.001.226 SOLO101 Extension tube 1.3M long for use with 517.001.230 telescopic extension pole 517.001.228 SOLO600 Carry all bag for detector test kit 517.001.242 SOLO720 Spare battery baton for use with SOL O 450/460 tester 517.001.243 SOLO724 Spare mains/car battery charger for SOLO720 battery baton 517.001.264 SOLO 610 Protective Carry/Storage Bag for Solo Detector Test Kit 517.001.255 SOLO330 Aerosol dispenser for use with all detector ranges. Connects directly to SOLO100/101 poles

517.001.233 CO Detector field test kit with 24 brickets for use with SOLO330 517.001.234 CO Fire Detector field test kit spare bricks (Pack of 24)

517.001.254 SOLO461 Cordless heat detector tester kit including: SOLO460 tester, SOLO720 battery batons and SOLO724 charger. (Connects directly to SOLO100/101 poles).

571.001.256 Suretest Solo aerosol tester can. For use with SOLO330 dispenser. Non-flammable, ozone and environment friendly. Approx 200 tests per can

800RT Detector Removal Tool


The 800RT detector removal tool fits the SOLO range of telescopic poles and allows the 800 Series detectors to be remotely fitted, removed and turned to the park position. The tool also enables detector dust covers to be easily removed. The 800RT is also compatible for use with M600 and M900 Series Low Profile detectors. Product Codes 516.800.917 800RT removal tool 572.005 800RT removal tool with ZETTLER pole adaptor

Sales Tools
Videos & Brochures
Product Codes PSV001 Carbon Monoxide Low Profile detector - English PALformat PSV008 Tyco MX Technology - English PALformat PSV009 Tyco MX Technology - English NTSCformat PSV010 Tyco MX Technology - German PAL format PSV011 Tyco MX Technology - Dutch PAL format PSV012 Tyco MX Technology - Spanish PAL format PSV013 Tyco MX Technology - Spanish NTSC format PBMX01 Tyco MX Technology Brochure - English version PBMX01E Tyco MX Technology Brochure - Spanish version

Page 45

APPROVALS LISTING OF COMPANY EQUIPMENT


Thorn Security Limited is registered by British Standards Institution to BS5750 : Part 1 Note: That while every effort is made to keep this document updated, some approvals will be renewed and new approvals will be acquired between updates. Any queries, reference approvals, should be made to the Approvals Engineer [TYCO SAFETY PRODUCTS} Sunbury-on-Thames. The approvals obtained for company equipment are listed in Table 1. The approval bodies are identified by the following abbreviations:AMSA ABS BT BASEEF A BR BSI BV CCG CCR CCS (ZC) CIRL CSA DDRK DMA DOT DNV DTI FM GL HRS IPT T IR KM & P A Australian Maritime Safety Authority. American Bureau of Shipping. British Telecom. British Approval Service for Electrical Equipment in Flammable Atmospheres. Brunamalastofnun Rikisins [Iceland Govt. Approval]. British Standards Institute. Bureau Veritas [France]. Canadian Coastguard. China Corporation Register of Shipping. China Classification Society. Construction Industry Research Laboratory [Australia]. Canadian Standards Association. DDR Schiffsrevision und Klassifikation [Germany]. Danish Maritime Authority [Sfartsstyrelsen]. Department of Transport [UK] - not used. Now Marine Certification Association [MSA]. Det Norske Veritas. Department of Trade and Industry. Factory Mutual [USA]. Germanischer Lloyd. Hellenic Register of Shipping An Roinn agus Telegrafa [Irish Posts, Telephones and Telegraphs]. India Radiology. Korean Marine and Port Authority. KRS LPCB LRS MIE MOI MSA NACOS S NC NKK NMA(S) NMD NSI NPTT NRC NRPB NSTC PRS PSB PTB RA RINA RNR RRS SAA SSL UL ULC USCG VdS Korean Register of Shipping. Loss Prevention Certification Board. Lloyds Register of Shipping. Spanish Ministry of Industry and Energy Italian Ministry of the Interior. Marine Certification Association National Approval Council for Security Systems. Not Coded. Japanese Register of Shipping.[Nippon Kaiji Kyokai]. National Maritime Administration [Sweden, Sjfartsverket]. Norwegian Maritime Directorate [Sjfartdirektortet]. Nederlands Shipping Inspectorate. Dutch Post Office. Nuclear Regulatory Commission [USA]. National Radiological Protection Board [UK]. China - National Supervisory Test Centre China. Polish Register of Shipping. Productivity Standards Board of Singapores Product Listing Scheme (PLS) Physikalisch Technisches Bundesanstalt [Germany]. Radiocommunications Authority [DTI] Registro Italiano Navale [Italy]. Rumanian Register of Shipping. Maritime Register of Shipping [Russia]. Standards Association of Australia. Scientific Services Laboratory of Australia Underwriters Laboratories of the United States. Underwriters Laboratories of Canada United States Coastguard. Verband der Sachversicherer e.V. [Association of Property Insurers] (Germany).

TABLE 1: APPROVALS LISTING OF COMPANY EQUIPMENT


Type ANN 840 ANN 880 CIM800 Description LED ANNUNCIATOR LED ANNUNCIATOR CONTACT INPUT MODULE Authority LPCB LPCB LPCB (PENDING) (ABS/BV/DNV/GL/KRS/LRS/NKK PENDING) COM820 CP820 CP820M CP830 CP830M CPU800 DIM800 FB800 FIM800 HVR800 IOB800 LAV800 LI800 MIM800 STATUS COMMAND MODULE INDOOR CALLPOINT INDOOR CALLPOINT OUTDOOR CALLPOINT OUTDOOR CALLPOINT CENTRAL PROCESSOR UNIT DETECTOR INPUT MODULE FUSE BOARD FIELD INTERFACE MODULE HIGH VOLTAGE RELAY MODULE VdS EXTINGUISHING INTERFACE LINE ISOLATOR MODULE MINI INPUT MODULE LPCB LPCB (PENDING) (ABS/BV/DNV/GL/KRS/LRS/NKK PENDING) LPCB (PENDING) (ABS/BV/DNV/GL/KRS/LRS/NKK PENDING) LPCB LPCB(PENDING), VdS (PENDING) LPCB LPCB LPCB (PENDING) LPCB (PENDING) VdS (PENDING) VdS (PENDING) LPCB (PENDING) (ABS/BV/DNV/GL/KRS/LRS/NKK PENDING) LPCB BV, LPCB, UL BV, LPCB, UL 811CH 814CH 801H 811H XLM800 ZX1 ZX4 ZXF ZXS ZXS 801B 801CH LOOP EXPANSION MODULE SINGLE LOOP PANEL TWO TO FOUR LOOP PANEL REPEATER PANEL 16 ZONE TWO LOOP SOLO PANEL 16 ZONE SOLO REPEATER PANEL STANDARD BASE CARBON MONOXIDE/ HEAT DETECTOR CARBON MONOXIDE/ HEAT DETECTOR CARBON MONOXIDE/ HEAT DETECTOR HEAT DETECTOR HEAT DETECTOR Type T2000R Description MARINE REPEATER PANEL Authority ABS, BV, KRS, UL, RINA (PENDING), LRS (PENDING), GL (PENDING) NKK (PENDING), USCG (PENDING) LPCB VdS VdS VdS VdS (PENDING) VdS (PENDING) LPCB LPCB, VdS ABS,DNV, KRS, LRS, MCA, RINA/ MOI (PENDING), NKK (PENDING) SSL LPCB,VdS ABS,DNV,KRS,LRS,MCA, RINA/MOI (PENDING), NKK (PENDING), USCG (PENDING) 812H 814H 801I 812I 814I 801IB 801PH 811PH HEAT DETECTOR HEAT DETECTOR IONISATION DETECTOR IONISATION DETECTOR IONISATION DETECTOR ISOLATORBASE OPTICAL/HEAT DETECTOR OPTICAL/HEAT DETECTOR UL SSL LPCB, VdS UL SSL LPCB, VdS LPCB,VdS ABS,DNV,KRS,LRS, MCA, UL RINA/MOI (PENDING), NKK (PENDING), USCG (PENDING) 812PH 814PH 801RB OPTICAL/HEAT DETECTOR OPTICAL/HEAT DETECTOR RELAY BASE UL SSL LPCB,VdS, (ABS/BV/DNV/GL/KRS/LRS/NKK PENDING) UL LPCB LPCB (PENDING) UL

INPUT/OUTPUT EXPANSION BOARD LPCB

MPM800 MX1000 MX4000 MXR MXS MXS OCM800 ODM800 PSB800 PSM800 RIM800 SIO800 SNM800

MULTI PURPOSE INTERFACE MODULE SINGLE LOOP PANEL TWO TO FOUR LOOP PANEL

REPEATER PANEL LPCB 8/16 ZONE SINGLE LOOP SOLO PANEL LPCB (PENDING) 8/16 ZONE SOLO REPEATER PANEL LPCB (PENDING) OPERATOR CONTROL MODULE OPERATOR DISPLAY MODULE POWER SUPPLY MODULE RELAY INTERFACE MODULE SINGLE INPUT/OUTPUT MODULE SOUNDER NOTIFICATION MODULE LPCB LPCB LPCB LPCB (PENDING) LPCB (PENDING) LPCB (PENDING) (ABS/BV/DNV/GL/KRS/LRS/NKK PENDING)

POWER SUPPLY BOOSTER MODULE LPCB

T2000

TWO TO FOUR LOOP MARINE PANEL ABS, BV, KRS, UL, RINA (PENDING), LRS (PENDING), GL (PENDING), NKK (PENDING), USCG (PENDING)

812RB 801SB 802SB 812SB

RELAY BASE SOUNDER BASE SOUNDER BASE SOUNDER BASE

Page 46

Standard AutoCAD Symbols


Tyco Electronic Product Group now has an IntraNet site devoted to users of AutoCAD Design Packages for electronic and electrical systems. The site has been set up with a view to utilising a common approach to AutoCAD output for drawing offices using Tyco Electronic Product Group products and systems. Initially this site includes Standard Symbols for Tyco MX Technology & MX-Graph, Fire and Access Symbol Name APM800.dwg APM800 Addressable Power Supply Monitor Products and also Diagrams for many Tyco Electronic Product Group products supplied from the UK, this will be expanded to include all Tyco Electronic Product Group products. Please encourage your CAD operators to visit this website. Even if you're business doesn't use all these products many of the symbols, schematics and drawings may be adapted quickly and easily for other products. Symbol Name CIM800.dwg CIM800 Contact Input Module If you require any further information on this or other aspects of CAD development please contact Lisa Thomson on Tel: +44 (0) 1932 743321, Fax: +44 (0) 1932 743330 or e-mail: lthomson@tycoint.com or alternatively visit our website at www.tycofire.com

Symbol Name DIM800.dwg DIM800 Detector Input Module

Symbol Name FCOTGX.dwg CODetector

Symbol Name FCPSTGX.dwg Weatherproof/I.S. Callpoint, Callpoint (Addressable and conventional)

Symbol Name FHTGX.dwg 801H Detector

Symbol Name FITGX.dwg 801I Detector

Symbol Name FPHDPTGX.dwg 801PHDuct Probe Detector

Symbol Name FPHTGX..dwg 801PHDetector

Symbol Name HVR800.dwg HVR800 High Voltage Relay Module

Symbol Name LAV800.dwg LAV800 VdS Extinguishing Module

Symbol Name LPS800.dwg LPS800 Loop Powered Sounder Module

Symbol Name MIM800.dwg MIM800 Mini Input Module

Symbol Name MXPANEL.dwg MX Panels (all types)

Symbol Name RIM800.dwg RIM800 Relay Interface Module

Symbol Name SNM800.dwg

SNM

SNM800 Sounder Notification Module

Symbol Name TM520.dwg TM520 Timer Module (non addressable)

Symbol Name AWORKST ATION.dwg PC

Page 47

Whos Where?
Product Management Sunbury +44 (0) 1932 743327 Field Support Sunbury Sales Order Processing (UK) Walthamstow +44 (0) 208 919 4000 Quality Assurance (UK) Walthamstow +44 (0) 208 919 4000 Manufacturing (UK) Walthamstow +44 (0) 208 919 4000 Customer Services (UK) Walthamstow +44 (0) 208 919 6202 +44 (0) 1932 743327 +44 (0) 1932 743330 Distribution Centre (UK) Letchworth +44 (0) 1462 667 700

+44 (0) 1932 743327

Research & Development (UK) Sunbury +44 (0) 1932 743333 Helpdesk Sunbury Tel: Fax:

tepghelp@tycoint.com

Sunbury The Summit, Hanworth Road Sunbury On Thames Middlesex TW16 5DB Telephone: +44 (0) 1932 743333 Facsimile: +44 (0) 1932 743330
The right is reserved to modify or withdraw any product or service without notice Product Catalogue PMC08 Issue 3
Tyco Safety Products 2002

Walthamstow 160 Billet Road Walthamstow London E17 5DR Telephone: +44 (0) 208 919 4000 Facsimile: +44 (0) 208 919 4040

Letchworth Dunhams Lane Letchworth Herts. SG6 1BD Telephone: +44 (0) 1 462 667 700 Facsimile: +44 (0) 1 462 667 777

www.tycosafetyproducts-europe.com

Das könnte Ihnen auch gefallen