Applicability
Introduction
Some customers may complain that the glove box may fall down after servicing the HVAC air cabin
filter. The instrument panel pin can become damaged during the removal/installation process
creating a condition where the damper does not seat properly. The following service procedure has
been provided for successful removal/installation of the glove box.
Warranty Information
Removal Procedure
1 Stopper
Installation
1. Pull the bottom of the dampener out until the clip Figure 4.
hole is visible.
1 Protective Tape
2 Stubby flate-blade screwdriver
2. Insert the tip of a Stubby flat-blade screwdriver into the clip hole to prevent the piston of the
dampener from retracting.
NOTE
Tape the screwdriver tip before use.
NOTE
• Always pull out the plunger and lock it in the extended position before installation
• Do not install the dampener to the instrument panel and then pull out the plunger. This will
cause the pin on the instrument panel to become weak or break