VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER

Maintenance Software Instruction Manual

7ZPNA4013D

JCY-1800/1850

VDR/S-VDR Maintenance Software Instruction Manual

RECORD OF REVISIONS
Rev 1.0 1.1 2.0 A First edition Revised 13.Report Setup for Remote Maintenance is added. Setup for NAV-I/F unit is added. Document Code is revised 7ZPNA4013A Registration method of VHF installation place was added. Operation method of conversion software was added. Language setup was added. Document Code is revised 7ZPNA4013B. Conforms to Windows Vista Document Code is revised 7ZPNA4013C. Note about the speed improvement of configuration data reception process by [Receive] button was added. The method for additionally installing RMB was added. RMS Setup method was changed. RMS Viewer operation instruction was added. Multicast setup method for VDR real-time output was added. Download method for the latest data from CF card was added. The operation method for opening configuration file was modified. The method for updating Capsule software was added. Document Code is revised to 7ZPNA4013D. Description Date 17-Oct.-06 19-Jan-07 17-Feb-07 9-Apr-07

20-May-08

28-Oct-08

8-May-09

DOC No. 7ZPNA4013D

JCY-1800/1850

VDR/S-VDR Maintenance Software Instruction Manual

DOC No. 7ZPNA4013AD

JCY-1800/1850

VDR/S-VDR Maintenance Software Instruction Manual

TABLE OF CONTENTS

1. 2.
2.1. 2.2.

Maintenance Software ................................................................................................................... 1 Starting and Quitting the Maintenance Software ........................................................................ 3
Starting the Maintenance software ............................................................................................................................3 Quitting the Maintenance software............................................................................................................................5

3.
3.1. 3.2.

Selecting Work Item....................................................................................................................... 7


Home screen.................................................................................................................................................................7 Work menu ..................................................................................................................................................................7

4.
4.1. 4.2. 4.3. 4.4. 4.5. 4.6. 4.7. 4.8. 4.9. 4.10. 4.11. 4.12.

Installation, Setup, and Operation Check .................................................................................... 9


Selecting the installation .............................................................................................................................................9 Receiving a configuration data and starting the diagnosis function......................................................................12 Sensor connection setup ............................................................................................................................................13 NSK connection setup ...............................................................................................................................................26 Option unit (NCT-72/63) connection setup..............................................................................................................31 Option unit (NCT-52A) connection setup ................................................................................................................52 Radar connection setup.............................................................................................................................................61 Microphone connection setup...................................................................................................................................68 VHF connection setup ...............................................................................................................................................73 VDR/S-VDR system setup ........................................................................................................................................76 Capsule setup .............................................................................................................................................................87 System Configuration File ........................................................................................................................................89

5.
5.1. 5.2. 5.3. 5.4. 5.5. 5.6. 5.7.

SYSTEM Screen ........................................................................................................................... 91


Buttons commonly used on the SYSTEM screen....................................................................................................92 Sensor section.............................................................................................................................................................93 Indicating the modified setup ...................................................................................................................................94 Diagnosis function .....................................................................................................................................................95 System status window ...............................................................................................................................................96 Operation button .......................................................................................................................................................98 File menu....................................................................................................................................................................98

6.
6.1. 6.2. 6.3. 6.4. 6.5.

EVENT Monitor ............................................................................................................................. 99


Starting.......................................................................................................................................................................99 Modification of EVENT list display.......................................................................................................................101 Opening the EVENT log file ...................................................................................................................................104 Saving the EVENT log file ......................................................................................................................................104 EVENT monitor record ..........................................................................................................................................105

7.
7.1. 7.2. 7.3. 7.4. 7.5.

Real Time Monitor (Menu) ......................................................................................................... 107


Starting.....................................................................................................................................................................107 NMEA monitor ........................................................................................................................................................108 Audio monitor.......................................................................................................................................................... 111 Radar monitor ......................................................................................................................................................... 112 Dry Contact monitor ............................................................................................................................................... 113

8.
8.1. 8.2. 8.3. 8.4. 8.5.

System Status Display................................................................................................................117


Starting..................................................................................................................................................................... 117 System status display Window ............................................................................................................................... 117 Starting System status display ................................................................................................................................ 119 Diagnosis lamp of orange in normal operation ..................................................................................................... 119 System status data file.............................................................................................................................................120

i DOC No. 7ZPNA4013D

JCY-1800/1850

VDR/S-VDR Maintenance Software Instruction Manual

9.
9.1. 9.2. 9.3. 9.4. 9.5. 9.6. 9.7.

Functions of Menu ..................................................................................................................... 121


Menu table ...............................................................................................................................................................121 Control .....................................................................................................................................................................122 Converting the Recorded data to general files (.txt .png .wav)............................................................................125 Config (Extract a setup file from a SysInfo.dat file).............................................................................................129 Downloading from CF CardCard Download ................................................................................................130 Error Code List .......................................................................................................................................................131 Software Version display.........................................................................................................................................132

10.
10.1. 10.2. 10.3.

Playback...................................................................................................................................... 133
Starting.....................................................................................................................................................................133 Playback Software...................................................................................................................................................134 Check the recorded data .........................................................................................................................................134

11.
11.1. 11.2. 11.3.

Frame Grabber Board (CKA-137) Setup - FGB Utility - .......................................................... 135


Check the Radar image specifications ...................................................................................................................135 Setup & Capture......................................................................................................................................................135 Tuning.......................................................................................................................................................................140

12.
12.1. 12.2. 12.3. 12.4. 12.5.

OPTION System Setup ........................................................................................................... 145


Starting.....................................................................................................................................................................145 Setup Procedure ......................................................................................................................................................146 Registration Information ........................................................................................................................................146 IP Address ................................................................................................................................................................146 Real Time Monitor Section .................................................................................................................................147

13.
13.1.

Report.......................................................................................................................................... 149
Starting.....................................................................................................................................................................149

14.
14.1. 14.2. 14.3.

Program Update ......................................................................................................................... 155


Program update of MCB, ARB and RMB.............................................................................................................155 Program update of FGB .........................................................................................................................................157 Program update of Capsule ....................................................................................................................................159

15.
15.1. 15.2. 15.3.

Playback Software Setup .......................................................................................................... 161


How to play back the downloaded data from the Capsule via Ethernet.............................................................161 How to play back the CF card data........................................................................................................................167 How to quit the Playback software ........................................................................................................................171

16.
16.1. 16.2. 16.3.

Remote Maintenance System Setup ........................................................................................ 173


Log in........................................................................................................................................................................173 HOME screen ..........................................................................................................................................................174 System screen...........................................................................................................................................................174

17.
17.1. 17.2. 17.3.

Installation .................................................................................................................................. 187


Uninstall the old version .........................................................................................................................................187 Installation procedure .............................................................................................................................................187 Language setting of maintenance PC.....................................................................................................................195

ii DOC No. 7ZPNA4013D

1. Maintenance Software
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

1. Maintenance Software
The maintenance software of JCY-1800/1850 is a PC-based application. The original task of the software is to check the equipment and to create the As-delivered software configuration. On board a ship, this is a versatile tool for a service engineer, too. The software helps him to install the equipment, reconfigure the setting, carry out the operation check and locate the fault, if any. 1) Software name: JCY1800-maint.exe 2) Language used: English 3) Characters used for entry: English one-byte characters only The number of characters that can be inputted is limited by each entry field. Entry over the maximum allowable number is denied. 4) Installation of the maintenance software: Use setup.exe for installing this software to the maintenance PC. Refer to Chapter 16 for the installation of this software.
For Windows Vista It is necessary to release UAC (user account control) for Windows Vista. Please install it according to the procedure of "Installation" in Chapter 17. When UAC has not been canceled, it is not possible to operate normally.

5)

OS: Windows XP Windows Vista (SP1 or after it)


Language setting If the Maintenance PC is not Japanese OS or English OS, please set language to the English (United States or the English (United Kingdom) in the Control Panel screen of Windows. Depending on language, the Maintenance software may not operate normally. Refer to "17.3 Language setting for Maintenance PC" about the setting method of language.

6)

PC: A laptop that meets the following or higher requirements: :Windows XP / Vista (SP1 or after it) OS :1GHz or more CPU Memory :512Mbytes or more(XP) : 1Gbytes or more(Vista) :CF card as a data backup medium of VDR/S-VDR PCMCIA card slot (A delivered card adapter is attached to the RCU.) :Ethernet (10/100Mbps) Communication I/F :1024768 (XGA) or more Screen resolution :Small size font only Display font

1 DOC No. 7ZPNA4013D

1. Maintenance Software
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

7)

Personal Firewall In case a personal firewall is run on the PC, suspend the function before using the maintenance software. Personal Firewall A personal firewall is a filtering facility of LAN communication link attached to OS (Windows XP, Vista) and the software to detect and isolate a virus. When a personal firewall is enabled; The VDR/S-VDR cannot communicate with the maintenance PC.

8)

Other requirements for maintenance: LAN cable (Built in the RCU.) Makes LAN connection from the Maintenance PC to the HUB unit of the RCU.

9) Connection port for the Maintenance PC

Connect the Maintenance PC to any of the VDR-LAN ports.

-------------- ABBREVIATIONS --------------Some of the abbreviations commonly used in this manual are: Abbreviations HVR/SVR RCU MCB FGB ARB RMB OPU DSC ACB Name of the Unit Capsule Recording Control Unit Main Control Board Frame Grabber Board Audio Recording Board Remote Maintenance Board Operation Panel Unit Digital Signal Converter (64CH/16CH) Analog Signal Convert Board (DSC option) Code NDH-316317 NDV-18001850 CDJ-2304 CKA-137 CHA-387 CDJ-2143 NCG-169 NCT-7263 CEF-60

2 DOC No. 7ZPNA4013D

2. Starting and Quitting the Maintenance Software


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

2. Starting and Quitting the Maintenance Software


2.1. Starting the Maintenance software
2.1.1. Starting procedure
1) To load the maintenance software, double click the Maintenance Software icon on the desktop assuming that the Maintenance software has already been successfully installed. (cf. Chapter 16) 2) The maintenance Software starts and then Login screen will appear.

2.1.2. Log in screen

3 DOC No. 7ZPNA4013D

2. Starting and Quitting the Maintenance Software


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

2.1.2.1. Selecting setup system (Setup Equipment)


Select a setup system from VDR, S-VDR or RMS.

2.1.2.2. Entering User name, Company name and Password (Register Information)
1) Register Information Enter the following user information, which will be recorded onto the VDR/S-VDR. User name Company name

2) Password The entered letters are indicated with asterisks (******). This is the password for field engineer. All "jrcvdr" is small letters.

2.1.2.3. Selecting Ethernet adapter


The Maintenance software will detect an Ethernet adapter in the PC automatically. When the PC has more than one Ethernet adapters, select wired LAN as an adapter interface to the VDR/S-VDR using button. Many models of recent laptop have not only wired LAN but also wireless LAN. Select wired LAN as the interface.

2.1.2.4. Adding IP address for VDR/S-VDR


Check the IP address and the Subnet mask which are registered to Ethernet adapter. The IP address for VDR/S-VDR maintenance is added. (192.168.110.200) The IP address added for VDR/S-VDR maintenance is deleted when the PC is rebooted.

2.1.2.5. Login
Click the [Next] button. After successful login to the VDR/S-VDR, HOME screen will appear.

4 DOC No. 7ZPNA4013D

2. Starting and Quitting the Maintenance Software


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

2.2. Quitting the Maintenance software


2.2.1. Check before quitting
Confirm the following items before logout when the installation is finished 1. All Entry lamps are lit green in the System screen. 2. All Diagnosis lamps are lit green in the System screen. 3. Any error event is not arisen on real time Event monitor. 4. The downloaded data from the capsule can be played back rightly. 5. The copied data from the CF card can be played back rightly. 6. Report files are saved with Report function.

2.2.2. Quitting procedure


Click the [Log out] button on the left side of each screen.

The maintenance software is shut down after logging out from the VDR/S-VDR.

5 DOC No. 7ZPNA4013D

2. Starting and Quitting the Maintenance Software


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

This page left blank intentionally

6 DOC No. 7ZPNA4013D

3. Selecting Work Item


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

3. Selecting Work Item


3.1. Home screen

Operation button

Work buttons

3.1.1. Selecting the work item


Click a work button on the Work section. The screen for the selected working item will appear.

3.2. Work menu


3.2.1. Installation
Select Installation for installing, setting and checking the VDR/S-VDR system. Following items are available on Installation. As-delivered factory setting Field setup Operation check of the VDR/S-VDR Annual inspection In field fault locating and remedy

7 DOC No. 7ZPNA4013D

3. Selecting Work Item


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

3.2.2. Playback
Select Playback for checking the recorded data on the VDR/S-VDR. The Playback software will be activated.

3.2.3. Option PC (VDR Real Time Monitor)


Select Option PC for setting up a real time monitor system. * Option PC merely enables/disables the output of a real-time monitor data. Refer to the "VDR/S-VDR Real Time Monitor Installation Manual" for details.

3.2.4. RCU Update


Select RCU Update for updating the program of each unit. MCB (Boot program/Application program) ARB (Application program) RMB (Boot program/Application program)

Update of FGB program can be performed from the menu of SYSTEM screen.

3.2.5. Capsule Update


Select Capsule Update for updating the following capsule software. Click the corresponding button after checking the capsules model connected to VDR/S-VDR. Capsules Model NDH-316 NHD-316A NDH-317 NDH-317A Button [NDH-316 Update] [NHD-316A Update] [NDH-317 Update] [NDH-317A Update] Note When logging in by VDR, selection is available. When logging in by S-VDR, selection is available.

8 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4. Installation, Setup, and Operation Check


4.1. Selecting the installation
4.1.1. Home screen

[Installation]

To configure the VDR/S-VDR, click the [Installation] button. The SYSTEM screen for the selected system (VDR/S-VDR/RMS) at log-in will appear.

JCY-1800

9 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

JCY-1850

JCY-1850 is different from JCY-1800 in;

The number of connectable sensor channels The capsule model

10 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.1.2. Operating procedure for installation


Set up and check the VDR/S-VDR on the SYSTEM screen according to the following procedure. Step Item Function triggered by; Contents The Maintenance software receives the system configuration data from the RCU. Click the [Receive] button. Setup information is displayed on the System screen after receiving. Check the box of each connection channel and each configuration unit referring to the Installation drawing. Click the Detail button of the section to set up. Select the connection channel in sensor section before clicking the Detail button. Click the Set button in the detail window after entering all data. Enter the detail information data of all section and each channel of the Sensor section. Click the Reboot button on the System screen. The RCU is operated by renewed system configuration data, after rebooting. Click the Diagnosis button on the System screen. Maintenance software shows the diagnostic results by the color of each lamp. Green lamp means OK. Check the receiving data by the real time monitor. If the diagnostic lamp is lit red or yellow, a problem arose out of setup, installation or wiring. Rectify the fault accordingly. The orange color of lamp means the equipment is under diagnosis. Check the recorded data by the Playback software. Make all lamps burn green and complete the setup. Report files are created. 10 5 13 See

Receiving the system configuration data

Receive button

4.2.1 4.3.1 4.4.1 4.5.1 4.6.1 4.7.1 4.8.1 4.3.2 4.4.2 4.5.2 4.6.2 4.7.2 4.8.2

Setting each connection

Check box for connection

3 4 5 6

Setting a detail information Transmitting a system configuration data to the RCU Setting up the System Rebooting the RCU Checking the diagnostic results

Each Detail button Set button in each detail window Repeat Step3 and Step4 Reboot button Diagnosis button and lamp Real time monitor

7 Receiving data

Correct, if there is a problem.

Return to STEP3

9 10 11

Recorded data Complete the setup Make the report

Playback All diagnostic lamps of System screen Report

Report folder is created on the Desktop of the PC automatically. Compress the folder, and upload the compressed files to the Ship list on the Marine service WEB.

11 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.2. Receiving a configuration data and starting the diagnosis function


4.2.1. Receiving a configuration data of RCU
Receive the configuration parameters from RCU and start the maintenance operation. 1) Click the [Receive] button.

2) Confirm the reception has been completed with the progress bar.

The configuration data reception process by [Receive] button is improved to high-speed for MCB and RMB software Ver2.0.1 or later. As a result, the data can be received instantly. Note that the earlier software version is not compatible for high-speed reception, so that it takes time as before.

4.2.2. Starting the diagnosis function


The state of VDR/S-VDR system and OK/NG of receiving data are indicated by the color of Diagnosis lamps. The meaning of each color is: (Green): OK (Red): NG (Orange): The system is under diagnosis

1) Click the [Diagnosis] button.

2) Confirm that the color of [Diagnosis] button changed to green. * If the [Diagnosis] button is clicked during the diagnosis function is on, the function will be stopped.

12 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.3. Sensor connection setup


4.3.1. Setting connection
Click the check box to have the sensor connected. 1) Each channel Check the check box of connected CH as follows. Enable: [ ] (checked) Disable: [ ] (unchecked)

Opening detail window Check box Selecting the subject CH of set up

Caution)

Cross out the check mark in the check box when the sensor connection setup is to be undone (from enable to disable) temporarily. In this case, do not forget to delete the setup data referring to 4.3.3.3. If the setup data remains when the mark is removed from the check box, the data from the same sensor may not be recorded via other channel.

4.3.2. Starting detail setup


The detailed setup window of each channel is displayed. 1) Selecting CH Click a radio button of setting sensor channel. 2) Click the [Detail] button on Sensor section, a detail setup window appears.

13 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.3.3. Selecting a recording data


Select the connection equipment and recording data according to the following procedure. The default value for receiving the data of the equipment chosen is set up automatically on the detail setting window.

4.3.3.1. In the case of new setting

Select a recording item from the pull-down menu. Click the [Next] button.

Select the equipment to be connected from the pull-down menu.

Select Other, when there is no appropriate item that should be set up. Enter an appropriate data for connected equipment on "Data" tab screen.

Caution) In case the recording data item to set up is not displayed: Subject recording data is already registered in other channel(s). Clear the setup of CH registered. Setting data are not cleared simply by changing the setting from enable to disable. Refer to the following procedure for deleting setup data.

14 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.3.3.2. Changing the registered setup data

To change the detail setup data registered; Choose No (Default) of radio button and click the [Next] button. To change the selected Recording item and selected Equipment; Click Yes of radio button and click the [Next] button. To clear the setup data; Click Do you want to delete information? and click the [Next] button.

4.3.3.3. Deleting the registered setup data


Click Do you want to delete information? and click the [Next] button. The registered setup data is deleted. In the following cases, delete the setting data of CH which are not connected. Example) As delivered, CH4 has been assigned as the input port of Gyro angle data in NMEA format. However on the ship actual Gyro angle is distributed by step signal repeater. Therefore the setup on CH4 has to be cancelled. Instead, CH33 shall be assigned as the port of Gyro angle data. 1) Setup error If a setup data remains despite the check on CH4 has been crossed out, the following error dialog will be displayed immediately after CH33 is checked.

2) Setup procedure Delete the setup data of the CH4 according to the aforementioned. Check the check box of CH33. Enter setup data for receiving the heading data into detail window of CH33.

15 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

Selection table
Recording item Date & Time/Ship' Position Equipment GPSMain) ID 41 Recording data Date and Time Ship's Position Local Geodetic Datum(DTM) GPS(Main+Sub) 71 Date and Time Ship's Position Local Geodetic Datum(DTM) GPS(Sub) 72 Other Other Other Ship's Speed Ship's Heading Depth Speed Log Gyro Compass Magnetic Compass Echo Sounder(Bow) Echo Sounder(Stern) Wind Speed and Direction Rudder Order/Response Anemometer Autopilot Rudder Angle Indicator ECDIS Engine Order/Response M/E Remote Control System Engine Telegraph Thruster Order/Response Thruster Bow1 Thruster Bow2 Thruster Stern1 Thruster Stern2 Thruster Acceleration and Hull Stress Door Status Fire Door Status Watertight Door Panel Hull Door Control Ramp Way Indicator Main Alarms Alarm Monitoring system Water Ingress Alarm System Bilge Alarm Panel Fire Detection System Steering Gear AIS Data AIS * * * 42 AIS VDO Data AIS VDM Data Status Information Main Alarm(ALR) Radar Selection Other RadarMain) 58 * Radar Selection Other ??VDO ??VDM ??TXT ??ALR ??PJRC * * * * * * Fire Door Status Watertight Door Status Hull Door Status ??DOR ??DOR ??DOR Hull Stress Monitor 49 52 53 54 55 56 57 47 59 48 45 46 51 50 43 44 Ground/Water Speed Ship's Heading Ship's Heading Depth Other Wind Speed and Direction Rudder Order, Manual Rudder Response, Manual Rudder Response, Manual Rudder Order, Automatic M/E RPM Set Order(CPP order) M/E RPM Actual Response(CPP order) Telegraph Order Position Thruster Response Thruster Response Thruster Response Thruster Response Thruster Response Hull Stress Sentence ID ??ZDA ??GGA ??GNS ??DTM ??ZDA ??GGA ??GNS ??DTM ??ZDA ??GGA ??GNS ??DTM ??VBW ??HDT ??HDG ??DPT ??DPT ??MWV ??HTD ??RSA ??RSA ??HTC ??PRC ??RPM ??ETL ??TRD ??TRD ??TRD ??TRD ??TRD ??HSS ??RMCV ??RMC ??RMCV ??RMC ??RMC ??GLL ??RMCV

16 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

Recording item Option Unit

Equipment DSC (CH13) DSC (CH14) DSC (CH15) DSC (CH16) DSC+A/D (CH13) DSC+A/D (CH14) DSC+A/D (CH15) DSC+A/D (CH16) NAV-IF (NCT-52A) NAV-IF (NCT-**)

ID 60 61 62 63 64 65 66 67 68 69

Recording data Dry Contact Data (CH13) Dry Contact Data (CH14) Dry Contact Data (CH15) Dry Contact Data (CH16) Dry Contact Data (CH13) A/D Convert Data (CH13) Dry Contact Data (CH14) A/D Convert Data (CH14) Dry Contact Data (CH15) A/D Convert Data (CH15) Dry Contact Data (CH16) A/D Convert Data (CH16) NAV-I/F Data(Option Unit) NAV-I/F Data(Option Unit)

Sentence ID ????? ????? ????? ????? ????? VRXDR ????? VRXDR ????? VRXDR ????? VRXDR ANADAT ANADAT

17 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.3.4. Detail setup window of sensor (standard)

4.3.4.1. Identification TAB screen


Set an identification data of connected equipment 1) Equipment Enter the name of the connected equipment. (GPS, Echo sounder, etc.) * Unless Other is selected, a default equipment name is entered automatically. 2) 3) Model Enter the model name of the connected equipment. Manufacturer Enter the name of the manufacturer of the connected equipment.

4) Serial No. Enter the serial number of the connected equipment. * If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial No. column.

18 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.3.4.2. Data TAB screen


Change entry data, when required. Enter a setup data when Other is selected as record item in pre-procedure.

4.3.4.2.1. Type Select the type of receiving sentences.


No. 1 2 3 4 5 6 Type NMEA AIS DRY-CNT DCNT+A/D NSK NAVI/F Connector General sensors AIS unit Digital signal converter unit (option) Equipment with built-in DSC (Addition of the optional A/D converter board) NSK unit (option) NAV-I/F unit (option) CH01CH32 CH13-CH16 Selectable CH CH01-CH32 CH01-CH16 CH13-CH16 CH13-CH16 Remark NMEA NMEA NCT-72/NCT-63 NCT-72/NCT-63 (A/D built-in) NCT-27B NCT-52A

19 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.3.4.2.2. Communication parameters and Sentence format Set the communication parameter and the sentence format. Once the type is selected, following parameters are automatically set as default. There is no need to change these values.

TYPE Baud Rate Data Bits Stop Bits Parity Checksum Header Delimiter Max Length Max Interval

NMEA 4800 8 1 None enable $ 0D0A 82 15

AIS 38400 8 1 None enable 0D0A 82 200

DRY-CNT 4800 8 1 None enable $ 0D0A 82 315

DCNT+A/D 4800 8 1 None enable $ 0D0A 82 15

NAV-IF 19200 8 1 None enable $ 0D0A 82 15

NSK 4800 8 1 None enable $ 0D0A 82 15

1)

Header Enter the header character. Enter $ for general sensor units. In case of connecting to the AIS, enter ! as a header character. When ! is entered, the RCU receives the NMEA sentences that have $ and ! as header. Delimiter Enter delimiter (the sign that means the end of the sentence). OD OA is recognized by the software as <CR><LF>.

2)

3) Maximum length of sentence Set the maximum length of the data sentence. Any data sentence of which length exceeds this maximum sentence length is denied and an error is arisen. The maximum length of the NMEA sentence is 82Bytes. 4) Maximum time interval of receiving Set the maximum time interval of receiving. If the time taken to receive a data sentence exceeds this limit, the sentence is denied and an error arises. For example, suppose ZDA, DTM, and GGA are set to be received. If the time taken to receive all ZDA, DTM and GGA exceeds the maximum time interval, all the information is denied and an error is raised.

20 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 4.3.4.2.3. Recording data Whether or not a sentence is recorded in the VDR/S-VDR is determined by the sentence ID. Any sentence of which ID is different from the specified is discarded and is not recorded in the VDR/S-VDR. 1) Recording item Select record item from the pull-down menu. Select Other, when the item was not found in the menu. 2) Sentence ID Select a sentence ID from the pull-down menu. Enter the sentence ID, if the sentence was not found in the menu. Type in maximum 7 characters, including the talker ID VDR/S-VDR Maintenance Software Instruction Manual

In case of NMEA sentence: The talker ID (2 characters) can be entered along with the sentence ID (3 characters). An uncertain character also can be entered using ?. Enter as many characters as you like (up to 7 characters). At least, include the sentence ID (3 characters). Examples: setting sentence ID for filtering ZDA sentences of GPS. ( all OK ) GPZDA GPZDA?? ??ZDA ??ZDA??

In case of option unit sentence: A/D : VRXDR DSC (NCT-72/63): ? (Since all sentences are recorded, "?" is used as a wildcard.)

3) Watch The watch on maximum interval of receiving can be set on each sentence. Set the Watch function of each NMEA sentence to enable or disable. The VDR/S-VDR will generate an error when the NMEA sentences set as Enable are not received within the set interval time. The VDR/S-VDR will not generate the error alarm when the NMEA sentences set as Disable are not received within the interval time. Enable: [ ] (checked) Disable: [ ] (unchecked) When the NMEA sentence ID is registered, checks will be entered as a default. In case of setting to disable On the equipment that does not transmit NMEA sentences periodically, the setting shall be Disable. Enable does make sense on the equipment that transmits sentence(s) periodically.

21 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.3.4.3. Checking the setup data


Confirm that there is no blank in setting data. Entry lamp informs the service engineer whether the entry is finished or still some items (Model, Serial number, etc.) remain.

(Green): (Yellow):

All entries are made. Blanks still remain. Look for a blank item and input a setup data.

4.3.4.4. Transmitting the setup data


Transmit the setup data to RCU. Transmit Click the [SET] button. Cancel Click the [Close] button.

4.3.4.5. Real Time Monitor


Monitors the real time NMEA sentence data which is collected in the RCU, and verify that the sentence specified by the installation drawings is collected correctly. 1) Procedures START:

Click the [Start] button. * Real time monitor is automatically started at the opening window. Click the [Stop] button.

STOP:

2) Selecting the monitor data type. Click the radio button of data type (RCV Data /REC Data) to monitor.

RCV Data: Monitors all the data that the RCU receives. REC data:

The sentence data which is not recorded on the VDR/S-VDR is also displayed. Monitors the sentence data which is recorded in the VDR/S-VDR. The sentence which is not recorded is not displayed even when it has been received. The monitored data is displayed by the sentence format currently recorded in the VDR/S-VDR.

22 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.3.4.6. Result of diagnosis


Confirm that the VDR/S-VDR receives a recording data. As for the diagnostic result of the [Sensor] section, the result is indicated on the "Diagnosis" lamp immediately after the setting has been completed. * Regarding the sections other than [sensor], rebooting after transmitting the setup data to RCU is required, therefore the Diagnosis result cannot be indicated with a lamp at setting.

(Green): (Red): (Orange):

The VDR/S-VDR receives a recording data The VDR/S-VDR does not receive a recording data. Check a receiving data by real time monitor. Under diagnosis

* To have the diagnostic function operated, click the [Diagnosis] button on System screen. If the function is not on, the Diagnosis lamp is off.

23 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.3.5. Detail setup window of GPS (sensor section)


Setup screen of GPS is a screen of exclusive use for connected two GPSs. Sub GPS setting is required when connected two GPSs to one port via a switcher.

4.3.5.1. Identification TAB screen


Set the identification data of connected GPS. 4.3.5.1.1. GPS information 1) Equipment Enter the name of the connected equipment. (GPS, DGPS, etc) 2) 3) Model Enter the model name of the GPS. Manufacturer Enter the name of the manufacturer of the GPS.

4) Serial No. Enter the serial number of the connected equipment. * If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial No. column. 4.3.5.1.2. Antenna position Enter the following values for antenna position. Distance from Bow/Stern/Port side/Starboard side to the antenna

24 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.3.5.2. GPS Selection TAB screen


Set up the GPS selection when the GPS (main+sub) is selected as a connection equipment.

1)

Switch position Select the logic of dry contact signal which is outputted by a GPS switcher. The GPS switcher is connected to TB406 PI-3 which is a terminal in the RCU. The VDR/S-VDR records the GPS equipment (main or sub) currently recorded as EVENT.

4.3.5.3. GPS Data TAB screen

1) Date and Time The sentence of Date and Time data is "ZDA" as default. When the GPS does not output ZDA, change the sentence to "RMC" instead. 2Datum When the GPS does not output DTM, clear the DTM setting.

25 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.4. NSK connection setup


4.4.1. Setting connection
CH33 and CH34 of Sensor section are the connection CH with NSK. Enable / Disable of heading data connection can be set up to CH33. Enable / Disable of speed data connection can be set up to CH34. 1) Each channel Check the check box of connected CH as follows. Enable: [ ] (checked) Disable: [ ] (unchecked)

Check box Select the subject CH of set up

Click to open detail window

4.4.2. Starting detail setup


The detailed connection setting window of each channel is displayed. 1) Selecting CH Click the radio button of setting sensor channel. 2) Click the [Detail] button on sensor section. Then detail setting window appears.

26 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.4.3. Detail setup window of Heading data (CH33

4.4.3.1. Identification TAB screen


Set an identification data of connected equipment which outputs a Synchro signal or a step signal as heading data. 1) Equipment Enter the name of the connected equipment. (Gyro, etc) 2) 3) Model Enter the model name of the connected equipment. Manufacturer Enter the name of the manufacturer of the connected equipment.

4) Serial No. Enter the serial number of the connected equipment. * If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial No. column.

27 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.4.3.2.

Heading TAB screen

4.4.3.2.1. Signal Type Select Synchro or Step as a signal type.

4.4.3.2.2. Ratio Select turn ratio from 1, 36, 90, 180 or 360 deg.

4.4.3.2.3. Gray Code Select Order Direction or Reverse Direction as rotation direction.

4.4.3.2.4. Transmitting a setup data

(Caution)

When the setup data of "Signal Type", "Ratio", or "Gray Code" are changed, transmit the setup data to RCU before inputting an initial value of heading. Click the [Set] button, to finalize the renewed data. * After the data transmission, RCU is rebooted automatically and setting data will become effective.

28 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.4.3.2.5. Heading Data Even when the entry of heading angle is not made from OPU, the initial value of heading can be inputted from Heading TAB screen.

1) Measured Value The current value of heading is displayed. The value displayed on this screen is the same as the value displayed on OPU. * Hading value is not displayed if the Real-time monitor has been stopped. Start the Real-time monitor in "Rec data" mode.

2) Initial Value Click the [Send] button after inputting an initial value. The inputted initial value is registered into the RCU. * "Initial Value" and "Measured Value" should show the same heading value immediately after the screen is opened. When the correct heading value is displayed, click the [Send] button without inputting an initial value.

3) Checking the heading value Check that the correct heading value is displayed on the "Measured Value".

29 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.4.4. Detail setup window of Ships Speed data (CH34

4.4.4.1. Identification TAB screen


Set an identification data of connected equipment which output a Pulse signal as ships speed data. 1) Equipment Enter the name of the connected equipment. (Speed log, etc.) 2) 3) Model Enter the model name of the connected equipment. Manufacturer Enter the name of the manufacturer of the connected equipment.

4) Serial No. Enter the serial number of the connected equipment. * If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial No. column.

4.4.4.2.

Ships Speed TAB screen

4.4.4.2.1.

Pulse

Select the rate from 100, 160, 200, or 400 pulse/NM.

30 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.5. Option unit (NCT-72/63) connection setup


In order to record a dry contact signal and an analog signal on VDR/S-VDR, the Digital Signal Converter (DSC: NCT-72/63 option) must be connected to the VDR/S-VDR. Set up the DSC following the procedure described hereunder.

4.5.1. Setting connection


CH 13, 14, 15, and 16 can accept the NCT-72/63. Enable / Disable of the DSC connection can be set up to the above-mentioned channels. 1) Each channel Check the check box of connected CH as follows. Enable: [ ] (checked) Disable: [ ] (unchecked)

Check box Select the setup CH

Open Detail window

4.5.2. Starting the detail setup


The detailed connection setting window of each channel is displayed. 1) Selecting CH Click the radio button for setting sensor channel. 2) Click the [Detail] button on sensor section and the detail setting window appears.

31 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.5.3. Selecting a recording data


Select the option unit (NCT-72/63) and recording data according to the following procedure. The initial value for receiving the data of the option unit (NCT-72/63) is set up automatically on the detail setting window.

4.5.3.1. In the case of new setting

Select Option Unit from the pull-down menu. Then click the [Next] button.

Select connected equipment from the pull-down menu. In case of connecting dry contacts Select the DSC (CH*). In case of connecting dry contacts and analog signals Select the DSC+A/D (CH*) (Optional Analog Conversion Board (CEF-60) must be built in the DSC.) Click the [Next] button.

32 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.5.4. Detail setup window of NCT-72/63


"Dry Contact" TAB is added as a detailed setting screen of dry contact input. When DSC+A/D is selected, "A/D" TAB is added as a detailed setting screen of analog signal input.

4.5.4.1. Identification TAB screen


Set an identification data of NCT-72/63. 1) Equipment "DSC" or "DSC+A/D" is entered automatically. The interior of the parentheses is Connection channel/equipment. 2) 3) Model Enter the model name of the connected equipment. (NCT-72/63) Manufacturer Enter the name of the manufacturer of the connected equipment. (JRC)

4) Serial No. Enter the serial number of the connected equipment.

33 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.5.4.2. Data TAB screen


According to selection of "DSC" or "DSC+A/D", an appropriate data is entered automatically.

DSC+A/D

DSC

4.5.4.3. Transmitting the setup data for NCT-72/63 connection


Transmit the setup data for NCT-72/63 connection to the RCU after entering all data on Identification screen. Click the [SET] button.

34 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.5.5. Detail setup window of dry contact (Dry Contact TAB screen)
This is the screen for transmitting and receiving the configuration file of NCT-72/63.

4.5.5.1. Program Version Display of NCT-72/63


Click the [Version] button. The program version of NCT-72/63 is displayed. In case the program version is not shown, DSC does not communicate with VDR/S-VDR.

4.5.5.2. Receiving the configuration file


Receive the configuration file of NCT-72/63. 1) Click the [Receive] button. 2) AT a communication link Monitor display, check that setting data are received. 3) Completion/failure of reception is displayed by a dialog. Verify that the following message appears.

4.5.5.3. Setup of NCT-72/63


Click the [Setup] button and the screen for the NCT-72/63 setup will appear.

35 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.5.5.4. Setup screen of sentence data

(alarm, door, etc.)

Dry contact data, such as alarm, door (open or close) and others should be changed into NMEA sentences. The screen for creating conversion table file will appear.

In editing not the configuration file that was received from NCT-72/63 but the configuration file saved, point to Open at File menu list.

4.5.5.4.1. Registration of sentence data converted from dry contact signal Sentence data are set up to each channel which accepts dry contact signal.

Connection CH Select a channel which is connected to the dry contact signal.

36 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

State of a dry contact signal


The condition of the equipment shown by OPEN/CLOSE of a dry contact signal is set up.

1) Alarm Select the inputting dry contact state (OPEN/CLOSE) when the connected equipment is in normal state.

2) Door Select the inputting dry contact state (OPEN/CLOSE) when the connected door is open.

creating a sentence data


Select each factor which constitutes the sentence data. 1) Dry contact information Select the dry contact information from the pull-down menu of each category according to the connected signal. Although categories are prepared from 0 to 3, the number of category to be set up is automatically determined by the selected data. Be sure to select a dry contact information from the pull-down menu which can be set up. An unnecessary setup category is not selectable.

37 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

* A selection setup from a tree structure The tree structure displayed on the left screen shows the dry contact inputs that can be registered. Sentence data can be set up by double-clicking each item.

Selected sentence DoubleClick

2) Identification number of a dry contact A signal of the same kind must be identified by respective number. Select the identification number listed in the pull-down menu. Be careful not to double select an identification number otherwise the same sentence data will be created

3) Comment Each sentence can be followed by a comment. Add a comment to each sentence by which a service engineer recognizes what the signal is.

38 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

3) Registering sentence data Click the [SET] button when all categories are selected and comment is inputted. The sentence is created according to the contents of selection and is added to the setup file.

4.5.5.4.2. Deleting and editing a sentence data registered The sentence registered into the setup file can be deleted. 1) Selecting a sentence Double-click the sentence displayed on the list. The CH number for deletion is displayed. 2) Deleting a sentence Click the [Delete] button. 2) Editing a sentence Set up a new sentence data after deletion.

4.5.5.4.3. When All Setup is Completed When there is no connection to Engine telegraph, move on to the 4.5.5.6.

39 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.5.5.5. Registration screen of sentence data for engine telegraph


This is a screen of exclusive use for Engine telegraph setup. 4.5.5.5.1. Screen change Click the Engine telegraph from Type menu.

4.5.5.5.2. Engine telegraph position Setup an engine telegraph position data according to the following procedure.

1) Selection of Enable / Disable Select either Enable (connected) or Disable (disconnected) of the engine telegraph position data by dry contact signals. In case of connecting, click the checkbox.

40 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

2) Selecting the connected dry contact signals On the selecting menu, all the signals of an engine telegraph position can be registered. The contact signal actually connected must be all selected. Check the connection signal.

3) Selecting the connection CH Select the connection CH of NCT-72/63 from the pull-down menu.

4) Selecting the state of dry contact signal Select a state of the dry contact signal (Open/Close) at "Active state".

2) 4) 3)

4.5.5.5.3. Sub telegraph position Set up a sub telegraph position data. Setup procedure is the same as Engine telegraph position.

4.5.5.5.4. Operation position Set up an operation position data of engine telegraph. 1) Selection of Enable / Disable Select either Enable (connected) or Disable (disconnected) of the operation position data by dry contact signals. In case of connecting, click the checkbox.

41 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

2) Enable setting Setup procedure is the same as Engine telegraph position.

3) Disable setting Select Other.

4.5.5.5.5. Order or Response (Status) Select the sentence type (Order / Response) of engine telegraph signals.

4.5.5.5.6. Engine and Propeller position Select the position of the engine and the propeller shaft. Single or on center line Port Starboard

4.5.5.5.7. Registration of Engine telegraph sentence data The NMEA sentence for engine telegraph is registered. 1) ETL sentence identification number Select the identification number in case of registering two or more ETL sentences. When registering only one sentence, "01" as a default must be selected. To register two or more sentences, select the total number. It can set up from "01" to "04."

2) Registering sentence data Click the [SET] button. The ETL sentence is registered.

42 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.5.5.6. All setup is completed


The configuration file created to NCT-72/63 is transmitted when all the setup is completed.

1) Transmit the configuration file. Click the [Send] button. 2) The setup screen is completed and returns to the Transmit/Receive screen of the configuration file. The configuration file is transmitted automatically to the NCT-72/63. 3) Save the configuration file To save the configuration file of NCT-72/63, it should be saved before transmitting the file. Click the [Save As] button, and save the configuration file.

4.5.5.7. Transmitting the configuration file


1) At the communication link Monitor display, check that setting data are transmitted. 2) Completion/failure of reception is displayed in a dialog. Verify that the following message appears. 3) When transmission is incomplete, click the [Send] button again.

43 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.5.5.8. Real time monitor of dry contact sentence


Check that the registration and the wiring of a dry contact signal are correct by the Real-time monitor.

4.5.5.8.1. Real Time Monitor The NMEA sentence can be monitored by the real time monitor on the setting screen. If the following dry contact signal monitor is available, check the sentence with this.

4.5.5.8.2. Dry contact monitor 1) Starting Click the [Monitor] button.

2) Operating Refer to 7.5.

44 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.5.5.9. Diagnostic result of dry contact signal


Enter a diagnostic result manually.

1) Dialog for entering a diagnostic result Click the [DSC Check] button. The dialog for entering a diagnostic result will appear.

2) Connection of dry contact signals Check that monitor icons (lamp, door) change according to the state of the connected dry contact signals. Enter the diagnostic result using the radio button (Good/No Good). 3) Sentence setup Check that the logic of a dry contact signal is correct. Alarm Normal: Green lamp / Abnormal: Red lamp Door A door icon shows the state of door (Open/Close). Click Good or No Good according to the diagnostic result. 4) Comment Enter a comment if the result is NG.

45 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.5.6. Detail setup window of analog signal (A/D TAB screen)


This is the screen to set up analog signals.

The following data that are inputted on the setup screen of each channel are displayed on this screen. Connection signal Current value Data unit

4.5.6.1. Setting connection of Analog signal


Enable / Disable of each Analog signal connection can be set up. 1) Each channel Check the check box of connected CH as follows. Enable: [ ] (checked) Disable: [ ] (unchecked)

4.5.6.2. Setting detail setup of Analog signal


1) Starting Click the [channel] button of detail setup channel.

46 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.5.6.2.1. Identification of Analog signal output Equipment Set an information data of connected Analog signal output equipment. 1) Equipment Enter the name of the connected equipment. 2) 3) Model Enter the model name of the connected equipment. Manufacturer Enter the name of the manufacturer of the connected equipment.

4) Serial No. Enter the serial number of the connected equipment. * If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial No. column.

4.5.6.2.2. Setup of Analog signal Specifications Type of signal (Voltage or Current), range and etc. are set by the strap on PCB (ACB: CEF-60). Maintenance software has no effect on them. 4.5.6.2.3. Calculating a coefficient Set up the parameters to translate the A/D conversion value (%) of the ACB into the real value displayed on the equipment. 1) Selecting CH Select an analog channel to set up.

47 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

2) Setting a minimum value Operate the analog signal output equipment so that it will output the minimum value. STEP1: STEP2: Input the minimum value displayed on the equipment. Input the A/D conversion value. Click the [Receive] button. A/D conversion value is inputted automatically. * Manual input is also possible. Click the [Set] button.

STEP3:

3) Setting a maximum value Operate the analog signal output equipment so that it will output the maximum value. STEP4: STEP5: Input the maximum value displayed on the equipment. Input the A/D conversion value. Click the [Receive] button. A/D conversion value is inputted automatically. * Manual input is also possible. Click the [Set] button.

STEP6:

4) Verify the calculated data Check the conversion formula is correct. STEP7: Check that the conversion value on Check value and the real value on the equipment are the same. Click the [Check] button. The converted value is displayed. When the converted value is not correct, repeat from STEP1. Set the coefficient of the formula. Click the [Apply] button.

STEP8:

Language setting If the Maintenance PC is not Japanese OS or English OS, analog data may not convert real value correctly, depending on language. Please set language to the English (United States or the English (United Kingdom) in the Control Panel screen of Windows. Refer to "17.3 Language setting for Maintenance PC" about the setting method of language.

48 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.5.6.2.4. Setting of Analog signal information The specification and information of the analog signal are set up.

1) Data unit Select the data unit of receiving data.


No. 00 01 02 03 04 05 06 Unit deg min
-1

rpm m/s km/s knots

2) Contents of connection data Select the contents of connection data. 3) Conversion formula The coefficients of the conversion formula are inputted automatically. * Manual input is also possible.

Conversion formula y=A1*10A2x+B1*10B2 y=Equivalent, x=A/D conversion value, A1, A2, B1, B2: Coefficient

4) Analog signal range Select the analog signal input range. This entry has nothing to do with analog-digital conversion. This is simply a record of input condition.

4.5.6.2.5. Setting detail setup of Analog signal Set up the data after completing all setup. Click the [Set] button.

49 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.5.6.3. Diagnostic result of analog signal


Enter a diagnostic result manually.

1) Dialog for entering a diagnostic result Click the [A/D Check] button. The dialog for entering a diagnostic result will appear.

2) Connection of analog signals Check that the A/D-conversion value of the connected analog signal is recorded. Enter the diagnostic result to radio button (Good/No Good). 3) Sentence setup Check that the conversion value is an appropriate value. Click Good or No Good according to the diagnostic result. 4) Comment Enter a comment if the result is NG.

50 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.5.6.4. Analog Signal Converting Board (CEF-60) setup


The parameters of the following inputs are set up by the strap on PCB.

1) Setting parameter of each channel Items Input channel use Input signal Range Parameter YES (enable) / NO (disable) Voltage 1V 5V 10V Current 4-20mA Remark Select YES for connecting analog signal or NO for not connecting signal. Chooses the type of signal. Chooses the range of input signal. Set up the range according to the type of signal.

2) Setting strap on the PCB (CEF-60)

CH0

CH1

CH2

CH3

CH4

CH5

CH6

CH7

51 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.6. Option unit (NCT-52A) connection setup


In order to record a synchro signal for rudder angle and wind direction and an analog signal for wind speed on VDR/S-VDR, the NAV-Interface unit (NAV-I/F: NCT-52A option) must be connected to the VDR/S-VDR. Set up the NAV-I/F following the procedure described hereunder.

4.6.1. Setting connection


CH 13, 14, 15, and 16 can accept the NCT-52A. Enable / Disable of the NAV-I/F connection can be set up to the above-mentioned channels. 1) Each channel Check the check box of connected CH as follows. Enable: [ ] (checked) Disable: [ ] (unchecked)

Check box Select the setup CH

Open Detail window

4.6.2. Starting the detail setup


The detailed connection setting window of each channel is displayed. 1) Selecting CH Click the radio button for setting sensor channel. 2) Click the [Detail] button on sensor section and the detail setting window appears.

52 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.6.3. Selecting a recording data


Select the option unit (NCT-52A) and recording data according to the following procedure. The initial value for receiving the data of the option unit (NCT-52A) is set up automatically on the detail setting window.

4.6.3.1. In the case of new setting

Select Option Unit from the pull-down menu. Then click the [Next] button.

Select connected equipment from the pull-down menu. In case of connecting NCT-52A Select the NAV-I/F (NCT-52A).

Click the [Next] button.

53 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.6.4. Detail setup window of NCT-52A


"NAV-I/F" TAB is added as a detailed setting screen of NAV-I/F input.

4.6.4.1. Identification TAB screen

NAV-I/F
Set an identification data of NCT-52A. 1) Equipment "NAV-I/F" is entered automatically. 2) 3) Model "NCT-52A" is entered automatically. Manufacturer "JRC" is entered automatically.

CH1
Set an information data of rudder angle output equipment. 1 Contents "Rudder" is entered automatically. It cannot be modified. * Synchro signal for rudder angle has to be connected to the CH1 of NCT-52A. 2) Equipment Enter the name of the connected equipment. 3) Model Enter the model name of the connected equipment.

54 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4)

Manufacturer Enter the name of the manufacturer of the connected equipment.

5) Serial No. Enter the serial number of the connected equipment. * If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial No. column.

CH2
Set an information data of wind direction output equipment. 1 Contents "Wind Direction" is entered automatically. It cannot be modified. * Synchro signal for wind direction has to be connected to the CH2 of NCT-52A. The following items are same as that of ch1 setting.

CH3
Set an information data of wind speed output equipment. 1 Contents "Wind Speed" is entered automatically. It cannot be modified. * Analog signal (1-5V or 4-20mA) for wind speed has to be connected to the CH3 of NCT-52A. The following items are same as that of ch1 setting.

4.6.4.2. Data TAB screen


According to selection of "NAV-I/F", an appropriate data is entered automatically.

55 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.6.4.3. Transmitting the setup data for NCT-52A connection


Transmit the setup data for NCT-52A connection to the RCU after entering all data on Identification screen. Click the [SET] button.

4.6.5. Detail setup window of NAV-I/F (NAV-I/F TAB screen)


This is the screen to set up parameters for converting Synchro and Analog signal to real value data.

"Rudder angle", "wind direction", and "wind speed" data from NCT-52A are displayed on real time. Verify the converted value after all setup. When the converted value is not correct, retry a setup of parameters.

56 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.6.5.1. Setting parameters for converting to rudder angle data


Click the [CH1] button. The screen to set up parameters for converting Synchro signal to rudder angle data is displayed.

Rudder Setting
Step 1) Step 2) Step 3) Step 4) Step 5)

Set the parameters for converting Synchro signal to rudder angle data. Control the actual rudder, so that the rudder angle value is set to "00.0." Select ratio from x2, x3, x4 or x5. Click the [Initialize] button. Wait for 5 seconds until initializing of NCT-52A is completed. Click the [Adjust] button. Verify that the correct rudder angle value is displayed on the Check value.

NAV-I/F data

The setup parameters to NCT-52A are displayed. Click the [Read] button. Each setup parameters are displayed.

57 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.6.5.2. Setting parameters for converting to wind direction data


Click the [CH2] button. The screen to set up parameters for converting Synchro signal to wind direction data is displayed.

Wind Direction Setting

Set the parameters for converting Synchro signal to wind direction data.

Step 1) Control the anemometer to stabilize the value of the wind direction. Step 2) Select direction from Order or Reverse. Step 3) Click the [Initialize] button. Wait for 5 seconds until initializing of NCT-52A is completed. Step 4) Input a wind direction value displayed on the anemometer. Step 5) Click the [Adjust] button. Step 6) Verify that the correct wind direction value is displayed on the Check value.

NAV-I/F data

The setup parameters to NCT-52A are displayed. Click the [Read] button. Each setup parameters are displayed.

58 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.6.5.3. Setting parameters for converting to wind speed data


Click the [CH3] button. The screen to set up parameters for converting Analog signal to wind speed data is displayed.

Wind Speed Setting

Set the parameters for converting Analog signal (1-5V or 4-20mA) to wind speed data.

Step 1) Input a wind speed value on 1V (or 4mA) anemometer outputting. Step 2) Input a wind speed value on 5V (or 20mA) anemometer outputting. Step 3) Click the [Adjust] button. Verify that the correct wind speed value is displayed on the Check value.
Language setting If the Maintenance PC is not Japanese OS or English OS, analog data may not convert real value correctly, depending on language. Please set language to the English (United States or the English (United Kingdom) in the Control Panel screen of Windows. Refer to "17.3 Language setting for Maintenance PC" about the setting method of language.

NAV-I/F data

The setup parameters to NCT-52A are displayed. Click the [Read] button. Each setup parameters are displayed.

4.6.5.4. Real time monitor of NAV-I/F unit outputting sentence


Check that the outputting sentence of NAV-I/F unit by the Real-time monitor. 4.6.5.4.1. Real Time Monitor The NMEA sentence can be monitored by the real time monitor on the setting screen.

Sentence format
$ANADATA, Rudder angle data, Wind direction data, Wind speed data

59 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.6.5.5. Diagnostic result of NAV-I/F data


Enter a diagnostic result manually. 1) Dialog for entering a diagnostic result Click the [NAV-I/F Check] button. The dialog for entering a diagnostic result will appear.

2) Receiving sentence data from NAV-I/F Check that the ANADATA sentence data from NAV-I/F is recorded. Enter the diagnostic result to radio button (Good/No Good). 3) Converting value Verify that the converting value is correct. Enter the diagnostic result to radio button (Good/No Good). 4) Comment Enter a comment if the result is NG.

60 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.7. Radar connection setup


4.7.1. Setting connection
Enable / Disable of Radar connection and the FGB can be set up. 1) Each channel Check the check box of Sub in case of connected two Radars. Enable: [ ] (checked) Disable: [ ] (unchecked)

* Check on Main cannot be cancelled.

2) Frame Grabber Board (FGB) S-VDR (JCY-1850) FGB is an option board in the S-VDR. Therefore the default setting of FGB is disable. When the FGB is installed into the RCU, Check the check box of FGB VDR (JCY-1800) VDRJCY-1800 FGB is a standard board in the VDR. Therefore the default setting of FGB is enable and the check cannot be cancelled.

4.7.2. Starting detail setup


Click the [Detail] button on Radar section then the detail setup window appears.

61 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.7.3. Detail setup window of Radar

4.7.3.1. Identification TAB screen


4.7.3.1.1. Identification data of Radar Set an identification data of connected Radar.

1) 2)

Model Enter the model name of the connected equipment. Manufacturer Enter the name of the manufacturer of the connected equipment.

3) Serial No. Enter the serial number of the connected equipment. * If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial No. column.

62 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.7.3.1.2. Setup file of FGB The setup file of FGB can be downloaded and uploaded. The setup file of FGB is saved in the FGB_UtilCKA137-JCY1800 folder hung under Install folder of the maintenance software. The Radar model or image specification is used as the file name. Select a correct setup file referring to the following instructions.

Radar model
Cap2-JMA9900-1800.txt Cap2 "2" means this setup file is for FGB: CKA -137. Reference: When Cap is not suffixed by 2 (i.e; Cap-..), the setup file is for CKA-129. JMA9900 Radar model 1800 1800 means the setup file is for JCY-1800/1850. Reference: 1700 stands for JCY-1700/S.

VESA
Cap2-1024x768-60Hz-1800.txt Cap2 "2" means this setup file is for FGB: CKA -137. Reference: When Cap is not suffixed by 2 (i.e; Cap-..), the setup file is for CKA-129. 1024x768 Image Resolution 60Hz Refresh rate 1800 1800 means the setup file is for JCY-1800/1850. Reference: 1700 stands for JCY-1700/S.

4.7.3.1.3. Two Radar images recording mode This is the recording mode applied when two radars are hooked up to the VDR/S-VDR. 1) Recording single image switching two radars This is called switching record mode, Standard recording method. Select the Single Record by Switch from the pull-down menu.

2) Recording both images The dual record mode can be selected as an option. To adopt the option, larger storage of memory of Capsule and CF card is required. Both Radar images can be recorded at a time with the extended memory. Select Dual Record from the pull-down menu.

4.7.3.1.4. In case of using Radar Interface Unit The Radar Interface Unit should be installed, when the display resolution of connected Radar unit is UXGA. 1) Setting the mode of Radar interface unit When the Radar Interface Unit is installed, select the NWP-46 from the pull-down menu. Enter the serial number of NWP-46. *Caution: The Radar interface unit has a cooling fan. In case None is selected, Fan alarm is not informed even when the alarm arises.

63 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.7.3.2. Radar Selection TAB screen

4.7.3.2.1. Select signal When two radars are connected and VDR/S-VDR records one of the two radar images by switching, set the switching signal. 1) Dry contact Select Dry contact, when recording channel is switched by dry contact signals outputted from a switcher. 2) NMEA Select NMEA, when recording channel is switched by the PJRC sentence outputted from JRC radar. 3) None (Auto) Select None, when the switching signal is not connected. Recording channel is switched by detecting a RGB signal. When radar images are sent from both radars, the image on CH1 is recorded.

4.7.3.2.2. NMEA Sensor channel which receives PJRC sentence for switching is set up automatically. Verify that a Radar connection channel is displayed.

4.7.3.2.3. Dry Contact Select the logic of the dry contact which is outputted by a switcher. AUTO mode is selected when both dry contact signals are of the same logic. Logic table of dry contact PI_1 OPEN OPEN CLOSE CLOSE

PI_2 OPEN CLOSE OPEN CLOSE

MODE AUTO CH1 record CH2 record PI_1 PI_2

* The switcher is not an optional unit of VDR/S-VDR.

64 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.7.3.3. Real Time Monitor


Monitors the real time Radar Image which is recorded to the VDR/S-VDR. This is to check the image recording operation. 1) Selecting the monitor CH The image received by CH1 is displayed on TAB Image 1 screen. The image received by CH2 is displayed on TAB Image 2 screen.

2) Starting to monitor START: Click the [Start] button. STOP: Click the [Stop] button.

3) Diagnosis Have a look the radar picture and judge the quality by yourself. Then click the [Image Quality check] button. Sort the acceptable or better picture to Good and the questionable or worse to No Good.

65 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

Judging the image quality. Click Good or No Good accordingly. If the latter is the case, write a comment.

* Click the [Help] button to have an advice on judging the Image quality.

* When a location gap of recording image exists or the focus of recording image is poor, adjust the value of the configuration file of the FGB referring to Chapter 11.

4.7.3.4. Checking the setup data


Confirm that there is no blank in setting data. 1) Entry lamp Error in setting entry (Model, Serial number, etc.) is warned by the Entry lamp.

(Green): (Yellow):

All entries are made. A blank remains. Look for the blank item and input the setup data.

2) Image Quality lamp Result of judgment on the image quality is indicated by the Image Quality lamp.

(Yellow): (Green): (Red):

The image quality is not judged yet. Open the "Image quality check" screen and enter the result of judgment. The image quality is judged good. The image quality is judged no good.

66 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.7.3.5. Transmitting the setup data


Transmit the setup data to the RCU. Transmit Click the [SET] button. Cancel Click the [Close] button.

4.7.3.6. Result of diagnosis


As for the diagnosis of the [Radar] section, the result is indicated by the "Diagnosis" lamp.

(Green): (Red): (Orange):

Result of diagnosis is good. Result of diagnosis is not good. Under diagnosis

* Setting of modified data of the "Radar" section is validated after the reboot of RCU. Therefore, when a setup data is changed, do not refer to the diagnostic result made before rebooting the RCU. * The diagnostic lamp is displayed also on the SYSYTEM screen. Click the [Reboot] button on the SYSTEM screen after completing setup, and check the diagnostic lamp of the SYSTEM screen. The meaning of each lampis; 1) FGB The Ethernet communication link condition of the Frame Grabber Board (FGB) and the Main Control Board (MCB) 2) Main The RGB signal from the main radar 3) Sub The RGB signal from the sub radar

* The diagnostic function needs to be in operation. A "Diagnosis" lamp becomes a blank display when the diagnostic function is not operating. A diagnostic function can be started with the [Diagnosis] button on SYSTEM screen.

67 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.8. Microphone connection setup


4.8.1. Setting connection
Enable / Disable of each Microphone connection can be set up. 1) Each channel Click the check box of connected CH as follows. Enable: [ ] (checked) Disable: [ ] (unchecked)

Opening detail window Check box

4.8.2. Starting detail setup


Click the [Detail] button on Microphone section then the detail setup window appears.

68 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.8.3. Detail setup window of Microphone

4.8.3.1. Identification TAB screen


Set an identification data of connected Microphone. 1) Type Select an indoor type or a waterproof type. 2) Place Enter the location where the microphone is installed. 3) Serial No. Enter the serial number of the Microphone unit. Serial number: XXXXnnn 4) Model Enter the model name of the connected Microphone. [Default setting data] Indoor type: NVT-161 Waterproof type: NVT-162

69 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.8.3.2. Real Time Monitor


Monitors the real time audio of Microphones that is recorded in the VDR/S-VDR to check the operation.

Caution:

Audio data is a mixture of triple input from each Microphone. correctly working, connects only one Microphone to monitor.

For checking that each Microphone is

1) Selecting the monitor CH Select a monitor channel with a radio button. 2) Starting monitor START: Click the [Play] button. STOP: Click the [Stop] button. 3) Volume Adjust the sound volume by a slide bar. Caution: When sound does not come out from the loudspeaker, check whether or not the speaker output of PC is OFF or sound volume is minimum.

4) Diagnosis Listen to the audio and judge the quality by yourself. Click the [Audio Quality check] button. Judge the audio quality on microphone 1-3, 4-6 and 7-9 respectively. Click Good or No Good accordingly. If the latter is the case, write a comment.

* Click the [Help] button to have an advice on judging the Audio quality.

70 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.8.3.3. Checking the setup data


Confirm that there is no blank in setting data. 1) Entry lamp Error in setting entry (Model, Serial number, etc.) is warned by the Entry lamp.

(Green): (Yellow):

All entries are made. A blank remains. Look for the blank item and input the setup data.

2) Audio Quality lamp Result of judgment on the audio quality is indicated by the Audio Quality lamp.

(Yellow): (Green): (Red):

The audio quality is not judged yet. Open the "Audio quality check" screen and enter the result of judgment. The audio quality is judged good. The audio quality is judged no good.

4.8.3.4. Transmitting the setup data


Transmit the setup data to the RCU. Transmit Click the [SET] button. Cancel Click the [Close] button.

71 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.8.3.5. Result of diagnosis


As for the diagnosis of the [Microphone] section, the result is indicated by the "Diagnosis" lamp.

(Green): (Red): (Orange):

Result of diagnosis is good. Result of diagnosis is not good. Under diagnosis

* Setting of modified data of the " Microphone " section is validated after the reboot of RCU. Therefore, when a setup data is changed, do not refer to the diagnostic result made before rebooting the RCU. * The diagnostic lamp is displayed also on the SYSYTEM screen. Click the [Reboot] button on the SYSTEM screen after completing setup, and check the diagnostic lamp of the SYSTEM screen. The meaning of each lampis; 1) MIC1-9 The result of Microphone test 2) ARB The operating state of data I/F of the Audio Recording Board (ARB) and the Main Control Board (MCB)

* The diagnostic function needs to be operation. A "Diagnosis" lamp becomes a blank display when the diagnostic function is not operating. A diagnostic function can be started with the [Diagnosis] button on SYSTEM screen.

72 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.9. VHF connection setup


4.9.1. Setting connection
Enable / Disable of each VHF transceiver connection can be set up. 1) Each channel Check the check box of connected CH as follows. Enable: [ ] (checked) Disable: [ ] (unchecked)

Click to open the detail window Check box

4.9.2. Starting detail setup


The detailed setup window of VHF transceiver is displayed. Click the [Detail] button on VHF section, the detail setup window appears.

4.9.3. Detail setup window of VHF

73 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.9.3.1. Identification TAB screen


Set an identification data of connected VHF transceiver. 1) 2) Model Enter the model name of the connected equipment. Manufacturer Enter the name of the manufacturer of the connected equipment.

3) Serial No. Enter the serial number of the connected equipment. * If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial No. column. 4) Place Please select the equipment place of VHF from the pull-down menu.

4.9.3.2. Real time monitor


Monitors the real time audio of VHF transceivers that is recorded in the VDR/S-VDR to check the operation. Caution: Audio data is a mixture of triple input from each VHF transceiver. For checking that each VHF transceiver is correctly working, connects only one VHF transceiver to monitor.

1) Starting monitor START: Click the [Play] button. STOP: Click the [Stop] button. 2) Volume Adjust sound volume by a slide bar. Caution: When sound does not come out from the loudspeaker, check whether or not the speaker output of PC is OFF or sound volume is minimum.

4) Diagnosis Listen to the audio and judge the quality by yourself. Click the [Audio Quality check] button. Judge the audio quality on VHF transceiver 1-3. Click Good or No Good accordingly. If the latter is the case, write a comment.

* Click the [Help] button to have an advice on judging the Audio quality.

74 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.9.3.3.

Checking the setup data

Confirm that there is no blank in setting data. 1) Entry lamp Error in setting entry (Model, Serial number, etc.) is warned by the Entry lamp.

(Green): (Yellow):

All entries are made. A blank remains. Look for the blank item and input the setup data.

2) Audio Quality lamp Result of judgment on the audio quality is indicated by the Audio Quality lamp.

(Yellow): (Green): (Red):

An audio quality is not judged yet. Open the "Audio quality check" screen and enter the result of judgment. The audio quality is judged good. The audio quality is judged no good.

4.9.3.4. Transmitting the setup data


Transmit the setup data to the RCU. Transmit Click the [SET] button. Cancel Click the [Close] button.

4.9.3.5. Result of diagnosis


As for the diagnosis of the [VHF] section, the result is indicated by the "Diagnosis" lamp.

(Green): (Red): (Orange):

Result of diagnosis is good. Result of diagnosis is not good. Under diagnosis

* Setting of modified data of the "VHF" section is validated after the reboot of RCU. Therefore, when a setup data is changed, do not refer to the diagnostic result made before rebooting the RCU. * The diagnostic lamp is displayed also on the SYSYTEM screen. Click the [Reboot] button on the SYSTEM screen after completing setup, and check the diagnostic lamp of the SYSTEM screen. The meaning of each lampis; 1) ARB The operating state of data I/F of the Audio Recording Board (ARB) and the Main Control Board (MCB) * The diagnostic function needs to be operation. A "Diagnosis" lamp becomes a blank display when the diagnostic function is not operating. A diagnostic function can be started with the [Diagnosis] button on SYSTEM screen.

75 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.10. VDR/S-VDR system setup


4.10.1. Starting the detail setup
The detailed setup window of VDR/S-VDR is displayed. Click the [Detail] button on VDR section, the detail setup window is displayed.

4.10.2. Detail setup window of VDR

VDRS-VDR

76 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.10.2.1. Identification TAB screen

4.10.2.1.1.Ships Identification Enter following ships identification data. Ships name IMO number.

4.10.2.1.2.Qty Entries made here are used by the Playback software. Enter the values.

4.10.2.1.3. VDR Identification Enter the VDR/S-VDR identification data. 1) Approval No. Enter the type approval number given by the ships class. 2) JRC shipping order Enter the shipping order number and the serial number of the RCU. 3) Serial No. Enter the serial number of the installed units that constitutes VDR/S-VDR.

77 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.10.2.2. Register Information TAB screen

4.10.2.2.1. Register information Registration information entered on the Log-in screen is displayed. Registration information which is stored in the RCU is displayed on receiving the configuration data. Registration information is updated to the data entered on the "Log in" screen after setting up.

1)

Initial The Initial means the setup in the JRC Mitaka factory. The maintainer name, company name, and the date & time (UTC) are automatically registered. Amendment The Amendment means the setup on board. The maintainer name, company name, and the date & time (UTC) are automatically registered.

2)

78 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.10.2.3. Maintenance TAB screen

4.10.2.3.1. Battery The expiry date of the battery is displayed. Enter the new expiry date of the battery, when you exchange the battery. The expiry date of the battery is indicated on the battery label. If the expiry date is approaching (i.e. the battery has to be replaced within a year), the message REPLACE BATTERY BEFORE: Year/Month flickers red as an alarm

4.10.2.3.2. FAN The expiry date of the two cooling fans in the PSU of RCU is displayed. Enter the new expiry date of the cooling fans, when you exchange two cooling fans. The life of cooling fans is four years. If the expiry date is approaching (i.e. the fans has to be replaced within a year), the message REPLACE FAN BEFORE: Year/Month flickers red as an alarm

79 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.10.2.3.3. Beacon of capsule Enter an information data of Beacon. 1) Serial No. Enter the serial number of the capsule. 2) Next Replacement The expiry date of the battery in the beacon of capsule is displayed. Enter the new expiry date of the battery in the beacon, when you exchange the beacon unit. The expiry date of the battery is indicated on the beacon label. If the expiry date is approaching (i.e. the battery has to be replaced within a year), the message REPLACE BEACON BEFORE: Year/Month flickers red as an alarm

4.10.2.3.4.Blackout test Check whether or not the VDR/S-VDR is operable even in a blackout. 1) Starting blackout test Click the [Test Start] button. Keep the [BLACKOUT TEST] switch on the panel of PSU in the RCU passed for 5 seconds. The result will be displayed on the Test result lamp.

2) Result of diagnosis A result is displayed on the Test result lamp.

(Green): (Red): (Orange):

Result of diagnosis is good. Result of diagnosis is no good. Under diagnosis

Whether the AC power is on or off is indicated in the Status window.

80 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.10.2.4. Software Version TAB screen

4.10.2.4.1. System Version The software version of JCY-1800/1850 system is displayed.

4.10.2.4.2.Maintenance number The Maintenance number (an intrinsic firmware number of the circuit board) of each unit (PCB) is displayed. Report all the Maintenance number for repairing.

81 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.10.2.5. PCB ID TAB screen

4.10.2.5.1. PCB Serial No. The serial number of each PCB is displayed. In case of replacing a PCB, enter the serial number of the new PCB which is installed into a unit. Option unit (DSC: NCT-72/63) When the DSC is connected to the RCU, the PCB serial number of DSC can be inputted * Report the serial number of PCB which is replaced for repairing.

82 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.10.2.6. Option TAB screen

4.10.2.6.1. NSK (Connection) Check the check box of the NSK (CH33, 34) when a Heading data or ships speed data is recorded via NSK in VDR/S-VDR. 1) Setting VDR:

The NSK-I/F board is an option board. Click NSK box when installing the NSK-I/F board newly into the RCU. The NSK-I/F board is a standard component. The box has already been checked as default.

S-VDR:

2) System window When the NSK (CH33, 34) is checked, NSK section is displayed in the System window.

NSK connection channel

4.10.2.6.2.Outputting alarm sentence (VDR System Status) VDR/S-VDR can output error information from serial port. This function is activated when other equipment requires receiving serial data from VDR/S-VDR. 1) Setting COM: CH:

Check the check box of the COM. Select a serial port for outputting the serial data From the CH13 to CH16 are selectable ports. The CH which connected the option unit (Dry contact / Analog data) is not selectable. * Caution Set up this function after setting up the option unit connection. (Refer to 4.5.)

83 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.10.2.6.3. Adding of RMB Remote Maintenance System When additionally installing RMB into S-VDR, set it according to the following steps.

Note) For more detailed setting method, refer to the installation guide accompanied to the RMB kit (NZK-1850).

1 Setup operation RMB Check the checkbox of RMB [Apply] button Click [Apply] button. The configuration data required for adding RMB is sent, and then S-VDR reboots automatically. *Note If RMB add-on setting is mistakenly done, uncheck the checkbox of RMB and click [Apply] button. The configuration data without the RMB installation is sent, and S-VDR restores the condition before adding RMB.

2 Registering RMB serial number Open PCB ID tab, and then register serial number assigned to the RMB PCB.

84 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.10.2.7. PI-1 to 3 TAB screen

4.10.2.7.1.Internal Dry Contact General dry contact signals can be inputted, and they can be recorded as NMEA sentence data. The number of dry contacts must be three or less. Set up the respective sentence according as the dry contact is on or off. Caution: The dry contact signals for switching Radars and switching GPSs are connected to these input ports. When the ports are occupied by the switching signals, these ports cannot be used for general dry contact signal entries.

4.10.2.7.2.Setup 1) Enable/Disable Enable / Disable of each PI port connection can be set up. Check the check box of the connected port. 2) Header of sentence data Enter the header of output sentence data. 3) OPEN sentence data The sentence data outputted when a dry contact opens is inputted. Enter the sentence data following the header. 4) CLOSE sentence data The sentence data outputted when a dry contact closes is inputted. Enter the sentence data following the header.

4.10.2.7.3.Real time monitor The real time sentence data recorded can be monitored. Make or break the contact as a try and verify that the sentence displayed repeats the try accordingly.

85 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.10.2.8. Checking the setup data


Confirm that there is no blank in setting data. 1) Entry lamp Error in setting entry is warned by the Entry lamp.

(Green): (Yellow):

All entries are made. A blank remains. Look for the blank item and input the setup data.

4.10.2.9. Transmitting the setup data

Transmit the setup data to the RCU. Transmit Click the [SET] button. Cancel Click the [Close] button.

4.10.2.10. Result of diagnosis (Blackout test)


As for the diagnosis of the [VDR] section, the result is indicated by the "Diagnosis" lamp.

(Green): (Red): (Orange):

Result of diagnosis is good. Result of diagnosis is not good. Under diagnosis

* Setting of modified data of the "VDR" section is validated after the reboot of RCU. Therefore, when a setup data is changed, do not refer to the diagnostic result made before rebooting the RCU. * The diagnostic lamp is displayed also on the SYSYTEM screen. Click the [Reboot] button on the SYSTEM screen after completing setup, and check the diagnostic lamp of the SYSTEM screen.

* The diagnostic function needs to be operation. A "Diagnosis" lamp becomes a blank display when the diagnostic function is not operating. A diagnostic function can be started with the [Diagnosis] button on SYSTEM screen.

86 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.11. Capsule setup


4.11.1. Starting detail setup
The detailed setup window of Capsule is displayed. Click the [Detail] button on Capsule section, a detail setup window appears.

4.11.2. Detail setup window of capsule

4.11.2.1. Identification TAB screen


Set an identification data of Capsule. 1) Model Select a model name from the pull down menu. The option model means a capsule of large storage capacity (3Gbyte). Two Radar images can be recorded at a time when this option is selected.

2) Serial No. Enter the serial number of the connected equipment.

87 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.11.2.2. Checking the setup data


Confirm that there is no blank in setting data. 1) Entry lamp Error in setting entry is warned by the Entry lamp.

(Green): (Yellow):

All entries are made. A blank remains. Look for the blank item and input the setup data.

4.11.2.3. Transmitting the setup data


Transmit the setup data to the RCU. Transmit Click the [SET] button. Cancel Click the [Close] button.

4.11.2.4. Result of diagnosis


As for the diagnosis of the [Capsule] section, the result is indicated by the "Diagnosis" lamp. An state of Ethernet communication link with the RCU and the capsule is diagnosed.

(Green): (Red): (Orange):

Result of diagnosis is good. Result of diagnosis is no good. Under diagnosis

* Setting of modified data of the "Capsule" section is validated after the reboot of RCU. Therefore, when a setup data is changed, do not refer to the diagnostic result made before rebooting the RCU. * The diagnostic lamp is displayed also on the SYSYTEM screen. Click the [Reboot] button on the SYSTEM screen after completing setup, and check the diagnostic lamp of the SYSTEM screen.

* The diagnostic function needs to be operating. A "Diagnosis" lamp becomes a blank display when the diagnostic function is not operating. A diagnostic function can be started with the [Diagnosis] button on SYSTEM screen.

88 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4.12. System Configuration File

4.12.1. File open


The VDR/S-VDR can be set up by opening a configuration file. (Not Receiving) Click Open in the File menu and select the configuration file to open.

4.12.2. File save


The system configuration data in the Maintenance software can be saved to a file. Click the Save in the File menu and input a file name to save.

89 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

This page left blank intentionally

90 DOC No. 7ZPNA4013D

5. SYSTEM Screen
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

5. SYSTEM Screen
On the SYSTEM screen, the connection setup, the operating state of VDR/S-VDR system and the condition (Good/No Good) of received signal can be verified.

Functions on the SYSTEM screen

Enable / Disable of each connection channel and the setup of connection interface Detail setting of each connection channel Reference to and registration of information of detail setup VDR/S-VDR Warning to wrong entry of setting Display of the receiving state (OK/NG) of each serial channel Display of the state (OK/NG) of VDR/S-VDR operation: Radar, Microphone, VHF, Capsule Display of the System status information of each section: Radar, Microphone, VHF, Capsule

91 DOC No. 7ZPNA4013D

5. SYSTEM Screen
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

5.1. Buttons commonly used on the SYSTEM screen


Here, how to operate the common buttons on the SYSTEM screen is described.

1) [Receive] button The Maintenance software receives the system configuration data of RCU Click the [Receive] button, progress of data reception is displayed on the progress bar placed at the bottom of the screen. The display of system screen will be updated by the received system configuration data.

2) [Diagnosis] button Diagnosis function is engaged by this button. Click the [Diagnosis] button then diagnosis function starts and the button burns green.

3) [Set] button This button is used to set up each system configuration data. Click the [Set] button then all the configuration data is transmitted to the RCU. * The button registers the system configuration data of each section in the detail setup window to RCU. It is unnecessary to use the [Set] button on the System screen when the detail window is opened to revise the setup data. Use the [Set] button on the System screen when all the system configuration data should be revised or only the individual check is changed.

4) [Reboot] button The button triggers to reboot the RCU. Click the [Reboot] button then the RCU will be restarted by renewed system configuration. Wait until the communication link of Maintenance software and RCU will be reestablished.

5) [All Default] button This button reconfigures the system back to the default setting as the standard connection of the VDR/S-VDR.

92 DOC No. 7ZPNA4013D

5. SYSTEM Screen
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

6) [Alarm Mute] button The [Alarm Mute] button is used to suspend the function of ALARM BUZZER of OPU. Click the [Alarm Mute] button then even when an error arises during the maintenance, the ALARAM BUZZER does not sound. The [Alarm Mute] button is lit green while the mute function is on. Click the green [Alarm Mute] button to cancel the Mute function. Do not forget to release the mute function before quitting the Maintenance software.

7) [ACK] button The [ACK] button on this screen works in the same way as the [ACK] button on the OPU. The [ACK] button is used to silence the ALARM BUZZER. In case multiple errors arose, presses the button as many times as the errors were raised.

5.2. Sensor section


The equipment information and recording data registered by detailed setup of sensor is displayed. Click the [Unit ID / Record item]/ [Manufacturer / Model] button. The information changes accordingly. * The ID means the error code which is displayed on the OPU.

Change of display

93 DOC No. 7ZPNA4013D

5. SYSTEM Screen
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

5.3. Indicating the modified setup


On the SYSTEM screen, when the setup data have been modified, the altered items are indicated by red. Besides, a button that is to validate a modification is also lit red.

5.3.1. Connection setup, [SET] button


If a box is checked, the color is changed from black to red and the button also blinks red. The red color means the item data has not been transmitted to the RCU yet. The indications are returned from red to gray after the revised data has been transmitted to the RCU.

Blinks in red

5.3.2. [Reboot] button


The [Reboot] button blinks red prompting the maintainer to reboot RCU to have RCU operated with the modified setup data. Click the [Reboot] button. The indications will be returned from red to gray after rebooting RCU.

Blinks in red

Caution:

Even when the [Reboot] button blinks red, it is not necessary to click the button immediately. When all the setup is completed, reboot the RCU, and check the operation of the VDR/S-VDR.

94 DOC No. 7ZPNA4013D

5. SYSTEM Screen
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

5.4. Diagnosis function


5.4.1. Diagnosis button
The received data from connected equipment and the operating state of the VDR/S-VDR are diagnosed, and the result is displayed on the lamp. Click the [Diagnosis] button. While the diagnostic function is on, the color of the [Diagnosis] button should be green. When the [Diagnosis] button is clicked during diagnosis, the function will be suspended.

5.4.2. Diagnosis lamp


The diagnostic result is displayed as follows. (Green): OK (Red): NG (Orange): Under diagnosis when the RCU starts up

Diagnostic items Section Sensor VDR Radar The Software diagnosed on; Recording (receiving) the sentence or not. CF Card, expiry date of battery, replacement date of FAN, Initial error and so on. Radar image Communication link of FGB and MCB: normal / abnormal Recording radar image: receiving the RGB signal / not receiving Quality of Radar image: judgment by service engineer Microphone audio MIC test result: OK / NG Control of ARB by MCB: normal / abnormal Quality of microphone audio: judgment by service engineer VHF audio Quality of VHF audio: judgment by service engineer Capsule Communication link of Capsule and RCU: normal / abnormal BER of Capsule: within the limit / beyond the limit

Microphone

VHF Capsule

5.4.3. Entry lamp


Error in setting entry (Model, Serial number, etc.) is warned by the Entry lamp.

(Green): (Yellow):

All entries are made. A blank remains. Look for the blank item and input the setup data.

95 DOC No. 7ZPNA4013D

5. SYSTEM Screen
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

5.5. System status window


Here, the System status data of each section are displayed. The system status shows the detail information of an error. * System status window is available at VDR, Radar, Microphone, VHF, Capsule sections. * Sensor section does not have the window because error information can be browsed at each detail setting menu. 1) Selection Click a section name (e.g. Radar) positioned upper left. 2) Displaying the System status System status window of selected section appears. Detail error information is shown in the window. To close the window, click [] at the upper-right corner.

Click the VDR section name

96 DOC No. 7ZPNA4013D

5. SYSTEM Screen
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

3) Sensor section Click [Sensor] positioned upper left of the sensor section. The recording sentence ID list appears.

97 DOC No. 7ZPNA4013D

5. SYSTEM Screen
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

5.6. Operation button


Click an operation button at the left of the SYSTEM screen. An operation window or an application selected is activated.

Button Log in

Operation Press the button to return to the Log in screen

See 2.1.

Home

Press the button to return to the HOME screen for selecting a work item The connection, setup, and monitoring the operation of VDR/S-VDR system are available. Event log during the operation of VDR/S-VDR system appears. The list helps the maintainer to locate the fault. Press the button to playback and check the recorded data in Capsule or in CF card. A report folder is created on the Desktop after completing installation. Report files are saved into this folder automatically. Press the button then the Maintenance software disconnects the link with RCU. The Maintenance software comes to an end.

3.1

System

4.1

Event

Playback

10

Report

13

Logout

2.2

5.7. File menu


System configuration data in the Maintenance software is saved/opened by the File menu.

98 DOC No. 7ZPNA4013D

6. EVENT Monitor
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

6. EVENT Monitor
Monitors the operation event of VDR/S-VDR to check that VDR/S-VDR system is working correctly. The EVENT monitor can display the received EVENT data from the VDR/S-VDR. Additionally, the EVENT monitor can display EVENT Log files in the VDR/S-VDR.

6.1. Starting
1) Click the [EVENT] button on the SYSTEM screen.

2) Select the language to display the Event data Select English or Japanese, and click [OK].

3) Real time Event monitor Immediately after the clicking OK, the Event monitor will be turned on. Then the Event monitor displays the real time EVENT data sent from RCU.

4) RCU reboots When the RCU is restarted by the [Reboot] button on the "SYSTEM" screen with the Event monitor turned on, the Event monitor can display the event data after starting of the RCU. Reboot the RCU for checking event data from starting of the RCU.

99 DOC No. 7ZPNA4013D

6. EVENT Monitor
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

An example of Event data

100 DOC No. 7ZPNA4013D

6. EVENT Monitor
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

6.2. Modification of EVENT list display


To have an access the old event data, download the event log files from the RCU. Event data from the very first operation of VDR/S-VDR are there. There are the Event log files that have been recorded on CF card by RCU.

6.2.1. EVENT log files

1) Click the [Get Event Log (CF Card)]. 2) How long it will take to finish the receiving by Progress bar. 3) Older event data until the last real time monitor turning on is added to the event list.

6.2.2. Event list after last boot display


The event data list can be displayed after the last boot of the RCU. Practice this function, when the older EVENT before the last boot is not needed.

1) Click the [Last boot] button. 2) The older event data before the last boot is cleared The [Last boot] button becomes blue color. 3) Click the [Last boot] colored blue. 4) Cleared old event data is displayed. (All event data display) The [Last boot] button becomes gray color again.

101 DOC No. 7ZPNA4013D

6. EVENT Monitor
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

6.2.3. Extract the event data


EVENT to display can be sorted out per category. The sorted out event data list will be displayed on another Window. Categories are: NMEA, FGB (Radar image), Audio, Capsule, Card, System Only one of the categories can be sorted out and displayed.

1) Click the button of the subject category name

2) The sorted out event data list is displayed on a newly opened Window. All category name buttons are now not selectable.

3) To change the EVENT category, close the present display Window of Extract EVENT. All category name buttons return to selectable.

102 DOC No. 7ZPNA4013D

6. EVENT Monitor
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

6.2.4. EVENT sort


The EVENT monitor previous sort function. 1) Click each field title. Then the sorted event list is displayed.

2) An event that plunges in during the sort is practiced is Not sorted, but is placed at the top of the list as the latest event.

6.2.5. EVENT clear


All the event data in the list can be cleared. 1) Click the [Clear] button.

6.2.6. Changing Display language


The language of event data list can be changed. 1) On the View menu, point to Language, and then click either English or Japanese.

103 DOC No. 7ZPNA4013D

6. EVENT Monitor
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

6.3. Opening the EVENT log file


The EVENT log file recorded by the RCU and the file saved by the EVENT monitor can be opened. The files are: The saved event log files in the CF card The event log files downloaded from the capsule The event log files saved by the Event monitor

1) Opening a file Point to Open on the File menu. Then the File dialog appears.

2) Selecting a file Select writefile.txt on the folder where Event log is saved. 3) Displaying the event log Event log data is displayed on the event list.

6.4. Saving the EVENT log file


The following event data displayed now on the EVENT monitor can be saved as a file. evt file: Recognized by Event monitor only. csv file type: Recognized by Excel, Notepad etc.

1) Saving a file Select Save or CSV Save on the File menu. Save: Saves evt file CSV Save: Saves csv file

2) Selecting a save folder Select a save folder on the File dialog.

104 DOC No. 7ZPNA4013D

6. EVENT Monitor
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

6.5. EVENT monitor record


The received EVENT data can be recorded as a file. 1) Record start Click the [Record Start] button. Select a save folder on the File menu. The start time of recording equals the file name. Then [Record Start] changes to [Record Stop].

2Recording file The record file is saved on the desktop.

3Record stop Click the [Record Stop] button. Then [Record Stop] changes to [Record Start].

105 DOC No. 7ZPNA4013D

6. EVENT Monitor
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

This page left blank intentionally

106 DOC No. 7ZPNA4013D

7. Real Time Monitor (Menu)


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

7. Real Time Monitor (Menu)


Although NMEA data, image data and audio data can be monitored at each Detail window in the SYSTEM screen, another real time monitor is available on the Monitor menu.

Comparison of Real Time Monitors


Monitors NMEA Real Time Monitor on the System menu Real Time Monitor at each Detail window The monitoring of all or some channels is Only the channel of the opened detail window supported. is monitored. The monitor channel is changed easily. The window size can be extended. The window is fixed. The radar image is displayed on the wide The radar image is displayed on the small window. window. No difference No difference

Radar image

Audio Dry contact signal

Starting
Each real time monitor can be started from the menu directly. Use these real time monitors for checking the received data only apart from setups.

7.1. Starting
1) Menu Click the Monitor menu. 2) Pull down menu Point to the item to be monitored and click it (NMEA, Audio, Radar, Dry contact).

107 DOC No. 7ZPNA4013D

7. Real Time Monitor (Menu)


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

7.2. NMEA monitor


Monitors the NMEA sentence data, and checks whether or not the sentence specified by the installation drawings is collected correctly.

7.2.1. Monitor conditions setup

If the specification of the laptop PC is relatively low, single channel monitoring is recommended. Incase two or more channel are monitored at a time, CPU load rises to 100%, and operation may stop. When the software freezes, press <Alt>+<Ctrl>+ <Delete> then Windows Task Manager will appear. Terminate the maintenance software there.

7.2.1.1.

Selecting the monitor channel

Select the CH to monitor. Click the CH to monitor from the pull down menu.

108 DOC No. 7ZPNA4013D

7. Real Time Monitor (Menu)


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

7.2.1.2.

Selecting the monitor data type

Click the monitor mode (RCV data/REC data).

RCV data: REC data:

Monitors all the receiving data from the selected channel. The sentence data which is not recorded by the VDR/S-VDR is also displayed. Monitors the sentence data which is recorded by the VDR/S-VDR only. The sentence which is not recorded is not displayed even when it is received. Monitors the data currently set in the VDR/S-VDR.

RCV data monitor Verify the receiving data by this in the event of receiving NG. When the wiring is reverse, unfamiliar characters will appear.

7.2.2. Monitor start and stop


1) Monitor start Click the [START] button. The monitoring channel indicator becomes Green. 2) Monitor stop Click the [STOP] button. The Gray light returns.

REC data
The addition and deletion of the CH to the monitor can be operated freely.

RCV data
Capable of single channel monitoring only. In case multi channels are monitored on RCV data, a mixture of received data is indicated.

7.2.3. Monitor pause


1) Pause Click the [Pause] button. Restart The [Pause] button changes to the [PLAY] button during the pausing. Click the [PLAY] button to restart.

2)

109 DOC No. 7ZPNA4013D

7. Real Time Monitor (Menu)


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

7.2.4. Event clear


The monitoring window can be cleared. Click the [Clear] button.

7.2.5. File save


Monitor data can be saved in a file. 1) Select a saving folder Click the [Browse] button to select the saving folder. The saving file name is invariably fixed to RtMonitor1.txt. 2) Save start Click the [SAVE START] button. The sentence data which is monitored now is saved in the text file. 3) Save stop The [SAVE START] button changes to the [SAVE STOP] button during the saving. Click the [SAVE STOP] button to stop saving.

7.2.6. Quit
1) Abide by the following procedure to quit monitoring. Otherwise an error arises. Stop all of the monitoring channels. Then click [Close] to quit.

2)

Before quitting the maintenance software, please make sure that the real time monitor has been stopped. Reboot RCU, if the maintenance software has been quitted without stopping the real time monitor to stop outputting the real time data.

110 DOC No. 7ZPNA4013D

7. Real Time Monitor (Menu)


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

7.3. Audio monitor


Monitors the Audio data which is recorded in the ARB to make sure that the operation is practiced correctly.

Play button Stop button Volume

7.3.1. Selecting the monitor channel


Click the selection button of CH to monitor. Audio1: MIC1-- MIC3 Audio2: MIC4-- MIC6 Audio3: MIC7-- MIC9 VHF: VHF1-- VHF3

Select the CH to monitor. Multiple channels cannot be played at a time. For each connected unit (MIC1,2,3,4,5,6,7,8,9, VHF1,2,3), connect only one unit to check the operation. Each monitor CH receives a mixture of 3 input signals. To verify that each unit is correctly working, it is necessary to connect only one unit to the monitor.

7.3.2. Monitor start and stop


1) Monitor start Click the [Play] button. The Audio of selected CH is outputted from the speaker. * Remember that a sound is not outputted unless the PC speaker is on. 2) Monitor stop Click the [Stop] button to stop monitoring.

The monitored sound is played about four second later than the sound source.

7.3.3. Changing the monitor channel


Keep the following procedure, when changing the monitor CH. Stop Change monitor CH Start

7.3.4. Quit
Click the [] button on the upper right of the window after monitor stop.

111 DOC No. 7ZPNA4013D

7. Real Time Monitor (Menu)


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

7.4. Radar monitor


Monitors the Radar Image which is recorded in the FGB to check the operation is working correctly.

7.4.1. Operation
No need to operate since the monitor functions of itself. The image that the VDR/S-VDR is recording is displayed. The image is updated every 15 seconds as well as the image record. The monitored image is displayed a few seconds later than the record time.

112 DOC No. 7ZPNA4013D

7. Real Time Monitor (Menu)


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

7.5. Dry Contact monitor


Monitors the dry contact data which is collected in the NCT-72/63, and checks whether or not the dry contact state specified by the installation drawings is correct. Be sure to check the collected data of all channels. This monitor analyzes the contents of NMEA sentence data outputted from the NCT-72/63, and the dry contact state is indicated by an icon.

7.5.1. Monitor start


No need to operate since the monitor functions of itself. The monitoring channel indicator becomes Green.

7.5.2. Monitor display


In order to check the dry contact state by a monitor window, make and break the dry contact. The NMEA sentence is outputted from the NCT-72/63 according to the make or break.

Sentence sent from the NCT-72/63 When the state of a dry contact changes. Every 5 minutes and at the time power supply is turned on (all sentences).

113 DOC No. 7ZPNA4013D

7. Real Time Monitor (Menu)


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

7.5.2.1. Dry contact of Alarm


A dry contact state is displayed with a lamp icon. Green lamp: The state is normal. Red lamp: The state is abnormal.

7.5.2.2. Dry contact of Door


The door state is displayed with an icon. : : The door is open. The door is close.

7.5.2.3. Engine Telegraph


The channel that is connected to the engine telegraph is displayed with yellow lamps. Click any yellow lamp, and the window for an engine telegraph appears.

The present position is displayed by a green lamp on "Engine telegraph position", "Sub-telegraph position", and "Operating location" . When the [Back] button is clicked, an engine telegraph window will be closed and returns to the dry contact state window.

114 DOC No. 7ZPNA4013D

7. Real Time Monitor (Menu)


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

7.5.3. Clear the result of monitor


The result of monitor can be cleared. Click the [Clear] button.

7.5.4. The wrong result of monitor


When the monitored dry contact state is the reverse to the outputting information of the connected equipment, correct the setting of the NCT-72/63. The dry contact state (make/break) must have been set the other way.

115 DOC No. 7ZPNA4013D

7. Real Time Monitor (Menu)


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

This page left blank intentionally

116 DOC No. 7ZPNA4013D

8. System Status Display


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

8. System Status Display


The operating state of VDR/S-VDR is displayed in detail. Check the error in detail by this screen. Although the system state is displayed in each category unit in the SYSTEM screen, all items can be displayed on this System Status screen.

8.1. Starting
Click the System Status from the System pull down menu.

8.2. System status display Window


All lamps should be green if the VDR/S-VDR is in normal operation.

8.2.1. System Control

117 DOC No. 7ZPNA4013D

8. System Status Display


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

8.2.2. Record Control

8.2.3. ROM Checksum

118 DOC No. 7ZPNA4013D

8. System Status Display


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

8.3. Starting System status display


8.3.1. When the diagnostic function is started
As the diagnostic result is already shown, no need to turn on the diagnostic function again. The [Diagnosis] button should be green.

8.3.2. When the diagnostic function is stopped


When the diagnostic function has been stopped, restart the function. Click the [Diagnosis] button. The [Diagnosis] button burns green and the diagnostic result is displayed.

8.3.3. Stopping the diagnostic function


Click the [Diagnosis] button during the diagnostic function is on. The function will be stopped.

8.4. Diagnosis lamp of orange in normal operation


Even if the VDR/S-VDR is operating normally, some diagnosis lamps do not become a green. 1) Capsule The Capsule section of the Record Control window

Write lamp of Config partition


It becomes a green lamp display only immediately after transmitting configuration data. If the RCU is rebooted, it will return to the orange display under diagnosis. 2) Microphone test The Audio section of the Record Control window

Running test lamps of Microphone test


A diagnostic lamp serves as an orange display under diagnosis until 12 hours pass and it carries out a microphone test, after starting. It is not necessary to check becoming a green lamp display at installation work.

119 DOC No. 7ZPNA4013D

8. System Status Display


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

8.5. System status data file


If the system configuration file (VdrDataInfo.dat)*1 saved at the report folder created after the completion of installation is opened, the system state file (Status.dat) saved at the same folder can be opened automatically, and the diagnostic result at that time can be displayed. So the diagnostic result at that time can be reproduced under offline without connecting the VDR/S-VDR. *1 The old Maintenance software (Version 1.2.0) save the system configuration file named McbDataInfo.dat. Refer to Chapter 13 about the report folder.

8.5.1. Connection with the VDR/S-VDR


The system status file cannot be opened while the Maintenance software is linked with the VDR/S-VDR, because the Maintenance software receives the system state data from the VDR/S-VDR. Disconnect the LAN cable.

8.5.2. File
Open the system configuration file (VdrDataInfo.dat). On the File menu point to Open and click.

8.5.3. System status data display


Start the System status display function. Click the [Diagnosis] button. The system state data in the selected file will be displayed.

120 DOC No. 7ZPNA4013D

9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

9. Functions of Menu
This chapter explains the auxiliary functions that can be executed from Menu.

9.1. Menu table


Regarding the function explained in another chapter as main function, the chapter and/or section number is shown in the Refer to; column. The arrow () means the function that is detailed in this chapter 9.

Menu File

Pull down menu Open

Function File open : System configuration file of the VDR/S-VDR or the RMS System status file of the VDR/S-VDR or RMS Moreover, by opening the system configuration file (SysInfo.dat, VdrDataInfo.dat) saved at the report folder created after the completion of installation, the system status file (Status.dat) saved at the same folder can be opened automatically, and then the diagnostic result at the completion of installation can be reappeared. Refer to chapter 13 about the report folder.

Refer to; -

Save Control System MCB Setup RMB Setup System Status FGB setup FGB Utility FGB Update HVR Event Monitor Event Monitor NMEA Audio Radar Dry Contact Convert

File save : System configuration file of VDR/S-VDR or the RMS Controls the VDR/S-VDR by the Maintenance software Edits system configuration data of the MCB Do not use this function without an instruction by JRC. Edits system configuration data of the RMB Do not use this function without an instruction by JRC. Shows the system status Shows the WEB of the FGB Do not use this function without an instruction by JRC. Adjusts the FGB Updates the program of FGB Shows the web of the capsule Do not use this function without an instruction by JRC. Real time monitor of EVENT Real time monitor of NMEA sentence Real time monitor of audio Real time monitor of image Real time monitor of dry contact Converts the recorded data to general file which is opened by standard application software on PC. NMEA data: Converts to text file Radar image data: Converts to PNG file Audio data: Converts to WAV file Extracts a setup file from Config file saved in the CF card and the capsule Download the latest sensor data file and Radar image file recorded in CF card. Shows meanings of Error code displayed on the OPU

Chapter 8 Chapter 11 14.2 Chapter 6 7.1 7.2 7.3 7.4

Data

Config Card Download Help Error Code List (English) Error Code List (Japanese) Software Version

Shows the software version of Maintenance software

121 DOC No. 7ZPNA4013D

9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

9.2. Control
The VDR/S-VDR can be controlled by the Maintenance software.

9.2.1. Starting
Click the Control on menu.

9.2.2. Reboot system


The MCB (VDR/S-VDR) and RMB (RMS) can be rebooted with remote control. 1) Click the button of the subject. ([MCB] button, [RMB] button) * This [MCB] button functions in the same way as the [Reboot] button.

122 DOC No. 7ZPNA4013D

9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

9.2.3. FGB maintenance mode


The MCB controls the FGB to record images during the VDR/S-VDR is in operation. The FGB may deny access by the maintenance software while the MCB is communicating to the FGB via Ethernet link. The FGB maintenance mode disconnects the link and makes the FGB accessible by the Maintenance software. * Following FGB-related functions have FGB maintenance mode started automatically therefore it is not necessary to turn on the FGB maintenance mode again. FGB setup FGB utility FGB update 1) To start, click the [START] button. 2) To stop, click the [Stop] button. * Caution: Radar image can not be recorded during the FGB maintenance mode. Be sure to stop this mode, before diving in FGB maintenance mode.

9.2.4. Initial Error Release


To cancel the Initial error (Error code: 01__) is released, click the [MCB] button.

9.2.5. Real Time Clock Setup


The date and time to the real time clock IC of the MCB or RMB can be confirmed and adjusted.

9.2.5.1.

Display the date and time

1) Click the subject unit button. ([MCB] button or [RMB] button) The date and time of a unit selected is displayed.

9.2.5.2.

Adjusting the date and time

1) Click the subject unit button. ([MCB] button, [RMB] button) The date and time of unit selected is displayed. 2) Enter the date and time. 3) Click the [Set] button. 4) Click the [Reboot] button of the target unit. (Refer to 9.2.1)

5) When the unit is rebooted, the entered date and time is set firm. Confirm the date and time after rebooting.

123 DOC No. 7ZPNA4013D

9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

9.2.6. Request Unit Mode and Function


The operation mode and function status of the MCB or the RMB can be displayed. 1) Click the unit to be checked. ([MCB] button or [RMB] button) MODE: FUNCTION: Application Normal Safe Download

Regularly, MODEApplication FUNCTIONNormal should be displayed. When the update of the program ended in failure and the software freezes with the function status remaining "Download", Request Unit Mode shifts the status back to Normal. Click the [Cancel] button.

If the [Cancel] button has no effect on shifting the function status back to Normal mode, there is something wrong with the equipment. Make call to service department and go into details.

124 DOC No. 7ZPNA4013D

9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

9.3. Converting the Recorded data to general files (.txt .png .wav)
The recorded data saved in the CF card or downloaded from the capsule can be converted to general files which are opened by standard application software on PC. Config data: Converts to text file (CSV) NMEA data: Converts to text file Radar image data: Converts to PNG file Audio data: Converts to WAV file

9.3.1. Starting of the Conversion software


1) Open the "Data" pull-down menu of the System screen, and click the [Convert] button.

Source Folder Selection button Convert Folder Selection button

[Convert] button

125 DOC No. 7ZPNA4013D

9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

9.3.2. Converting to general files


1) Selecting of source folder Click the Source folder selection button, and select folders which saved recorded data. In order to convert downloaded data from VDR/S-VDR, select folders or files which are enclosed by the dashed line. xxxxxYYYYMMDDhhmmssPlaylist VDR Init Log Audio Visual

In order to convert recorded data of the CF card, select folders or files which were enclosed by the dashed line. CF card drive Init Log Audio Visual

2)

Converting Click the [Convert] button. Then conversion of files starts. When conversion starts, conversion status is indicated by progress bar. And converted files are indicated in the list box. [Convert] button

126 DOC No. 7ZPNA4013D

9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

3)

By drag and drop, recorded data can be converted as follows also. In case of drag and drop, not only a converted folder, but also a file can be selected.

Drag and Drop

127 DOC No. 7ZPNA4013D

9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

9.3.3. Converted file (Industry Standard Formats files)


The Conversion software creates the converted files as follows. Data Configuration Information Digital Sensor Data Audio File Name YYMMDD,hhmmss,CF,????????.csv YYMMDD,hhmmss,DD,????????.txt YYMMDD,hhmmss,M1,????????.wav YYMMDD,hhmmss,M2,????????.wav YYMMDD,hhmmss,M3,????????.wav YYMMDD,hhmmss,V1,????????.wav YYMMDD,hhmmss,R1,????????.png YYMMDD,hhmmss,R2,????????.png Note

Mix MIC-CH1, CH2 and CH3 Mix MIC-CH4, CH5 and CH6 Mix MIC-CH7, CH8 and CH9 Mix VHF-CH1, Ch2 andCH3 Main Radar Image Sub Radar Image

Radar Display Video

YYMMDD: Date hhmmss: Time (UTC) ????????: IMO No. (If IMO number is not entered, automatically converts to 99999999.)

128 DOC No. 7ZPNA4013D

9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

9.4. Config (Extract a setup file from a SysInfo.dat file)


A setup file of each unit (MCB, FGB, etc.) can be sorted out from a SysInfo.dat file saved in the CF card or the capsule.

9.4.1. Starting
1) Click the "Config" from the "Data" pull down menu on the system screen.

9.4.2. Selecting a Config file


1) Select a file Click the [Open file] button, and select the SysInfo.dat file saved in the Init folder of recorded data.

9.4.3. Saving a setup file of each unit


Select the unit of which setup file will be saved. 1) Selecting the unit Click the button of the unit. 2) Saving a file Select a save folder, and input the file name.

129 DOC No. 7ZPNA4013D

9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

9.5. Downloading from CF CardCard Download


The latest sensor data file and Radar image file recorded in CF card can be downloaded. does not correspond to download of an audio file. The software, however,

1Click Card Download by opening the pull-down menu of Data on System screen.

2Select the file desired to be downloaded, and then click [Download] button.

3Downloaded file is saved on the desktop folder.

Since the Radar image file is converted to PNG format after being downloaded, the file can be checked by opening it immediately after that.

130 DOC No. 7ZPNA4013D

9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

9.6. Error Code List


Accesses to the error code displayed on OPU and the recommended remedy.

9.6.1. Starting
1) Click the "Error Code List" from the "Help" pull down menu on the system screen.

9.6.2. Error code list


The error code list is displayed. 1) Click the icon of SYSTEM Code No.

2 Please click 3 Please click

icon of each category. icon of each error code No.

The content, the cause, and the correspondence method of the error code are displayed at the right of the screen.

131 DOC No. 7ZPNA4013D

9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

9.7. Software Version display


The software version display Window appears.

9.7.1. Starting
1) Click the Software Version from Help menu.

9.7.2. Software version display window


This window should appear.

132 DOC No. 7ZPNA4013D

10. Playback
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

10. Playback
Verify that the installation and the setup have been finished successfully and the VDR/S-VDR works satisfactory by playing back the data of the capsule and the CF card.

10.1. Starting
10.1.1. Start on the SYSTEM screen
Click the [Playback] button on the SYSTEM screen.

10.1.2. Start on the HOME screen


When the HOME screen is displayed, start the Playback software with the [Playback] button of Work section. 1) Click the [Playback] button.

133 DOC No. 7ZPNA4013D

10. Playback
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

10.2. Playback Software


The Launcher of Playback software starts. The recorded data of VDR/S-VDR are saved on the Capsule and the CF card. Do not forget to playback and check both of them. 1) Capsule The recorded data is downloaded from the Capsule to the maintenance PC via LAN. 2) CF card The recorded data is copied from the CF card to the maintenance PC with a card adaptor.

Check the recorded data of both the capsule and the CF card at the end of installation. Playback procedure of capsule data is different from that of CF card. Playback and check the recorded data referring to the procedure mentioned in 15. Playback Software setup.

Refer to the instruction manual of Playback software for details

10.3. Check the recorded data


The recorded data shall be as follows: All NMEA sentences are recorded. Radar images are recorded. The selected radar images are recorded in two radar connection system. Conversation in the bridge and wings is recorded Communication of VHF transceiver is recorded

134 DOC No. 7ZPNA4013D

11. Frame Grabber Board (CKA-137) Setup - FGB Utility JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

11. Frame Grabber Board (CKA-137) Setup - FGB Utility FGB_Utility software is useful for setting up and tuning the Frame Grabber Board CKA-129/CKA-137. The setup menu has Board setup function with the aid of capture setup file and other file. The tuning menu allows maintainer to tune sync polarity, horizontal/vertical synchronization and sampling phase.

11.1. Check the Radar image specifications


For proper capture setting, check the Radar image specifications (VESA format only) first then verify the following items. Resolution: (ex. 1280x1024) Vertical synchronous signal frequency (Refresh rate): (ex. 60 Hz) Horizontal synchronous signal frequency: (ex. 75 kHz) Polarity of Vertical synchronous signal: (ex. Positive or Negative) Polarity of Horizontal synchronous signal: (ex. Positive or Negative)

11.2. Setup & Capture


11.2.1. Start the "FGB Utility" program
Click the FGB Utility from System menu of the VDR/S-VDR Maintenance Software.

135 DOC No. 7ZPNA4013D

11. Frame Grabber Board (CKA-137) Setup - FGB Utility JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

11.2.2. Selecting the channel for tuning


a) Click the .
. In case Ch2.txt NG message appears, align the capture setting using [Ch 2

To tune the channel 2, click the

capture setting] menu, referring to the next section. Immediately after the click, the following message appears. This message appears only on the first connection to the board.

b) Click the [OK] button.

c) "Changed to channel 1" message appears at the left bottom corner of the window.

11.2.3. Checking the captured Radar image


Check the Radar image captured by FGB (CKA-137) following the instructions a) to c). a) Click [Information (I)] -> [ADC status] menu. The following message appears.

b) Click the [No] button. "ADCtxt_Analysis Function" window appears.

136 DOC No. 7ZPNA4013D

11. Frame Grabber Board (CKA-137) Setup - FGB Utility JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

Measured value

Sync Activity ch 1 Sync Activity ch 2 V sync polarity H sync polarity V sync frequency H sync frequency: Total line number Setup value V sync polarity H sync polarity

Resolution (estimated value)

c) Check that the Radar image format measured by CKA-137 is the same as that of the Rader specifications.

Resolution (estimated value): Vertical synchronous signal frequency (Refresh rate): Horizontal synchronous signal frequency: Vertical synchronous signal polarity: Horizontal synchronous signal polarity:

If the Sync Activity column is inactive, most probably synchronous signal could not be detected by the board. Verify the wiring, signal output and input channel.

137 DOC No. 7ZPNA4013D

11. Frame Grabber Board (CKA-137) Setup - FGB Utility JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

11.2.4. Set the capture setup


a) Click the [Setup(S)] -> [Ch 1 capture setting] menu. (To practice capture setup on channel 2. Click the [Ch 2 capture setting] menu.) File selection window appears.

b) Click the "CKA137-JCY1800" folder. (If CKA-137 board is installed in JCY-1700, click the "CKA137-JCY1700" folder.)

c) Click the capture setting file. File name is formatted as shown bellow. JRC Radar setting: Cap2-"Radar model name"-1800.txt | | | CKA-137 board installed in JCY-1800/1850 ex. JMA9900 VESA format setting: Cap2-"Resolution"-"V sync frequency"-1800.txt Resolution: 800x600, 1024x768, 1152x864, 1280x960, 1280x1024, 1600x1200 pixels V sync frequency: 60, 70, 72, 75, 85 Hz (a display of 1600x1200 resolution meets 60 Hz only.)

138 DOC No. 7ZPNA4013D

11. Frame Grabber Board (CKA-137) Setup - FGB Utility JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

d) Click the [Open] button on the file select window. The following message appears. If "Capture1.txt write NG" message appears, retry step a) to d).

e) Click the [OK] button on the message box.

11.2.5. Capturing the Radar image


Capture the Radar image following the next instruction. a) Click the icon at the top of menu.

"Finished the image capture." is displayed at the left bottom corner.

b) Click the

icon.

Captured PNG image will be displayed.

139 DOC No. 7ZPNA4013D

11. Frame Grabber Board (CKA-137) Setup - FGB Utility JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

11.3. Tuning
Tune the image in the following order. 1) Sync polarity tuning 2) Horizontal position tuning 3) Vertical position tuning 4) Sampling Phase tuning

11.3.1. Sync polarity tuning


a) Click [Information (I)] -> [ADC status] menu. "ADC.txt response" window appears. b) Click the [No] button. "ADCtxt_Analysis Function" window appears. c) Check the H sync polarity. If the measured H sync polarity is the same as that of the setup, go to the next section. If not, go to d).

Measured value

Setup value

140 DOC No. 7ZPNA4013D

11. Frame Grabber Board (CKA-137) Setup - FGB Utility JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

d) Click the [Tuning (T)] -> [H Sync polarity reverse] The following message appears.

e) Click the [OK] button. The click reverses the H sync polarity and captures the image. Then the following message appears.

f) Click the [OK] button.

g) Have a look on the [ADC status] menu, and check that the measured H sync polarity is the same as that of the setup. Regarding the V sync polarity, follow the same procedure using [V Sync polarity reverse] menu.

141 DOC No. 7ZPNA4013D

11. Frame Grabber Board (CKA-137) Setup - FGB Utility JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

11.3.2. Horizontal position tuning


If the captured image is shifted horizontally, tune the Horizontal position. If the captured image has been shifted greatly, tune by the mouse. If the shift is small go to the manual (fine) tuning.

11.3.2.1. Coarse tuning by the mouse a) Click the [Tuning (T)] -> [Horizontal POSI. Mouse] menu. The following message appears.

b) Click the [OK] button. Then automatic image capture starts, and the following message appears.

c) Click the [OK] button on the message box. The message box disappears.

d) Click the horizontal edge of the image. Dont care the Y coordinates.

Click the left (right) edge of the image.

The following message appears.

142 DOC No. 7ZPNA4013D

11. Frame Grabber Board (CKA-137) Setup - FGB Utility JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

e) To practice horizontal position tuning at this point, click [Yes]. the horizontal edge of the image.

Or to retry the image shift, click [No] and tweeze

After successful horizontal position shift and image capture, the result message appears.

f) Click the [OK] button on the message box.

11.3.2.2. Manual (fine) tuning a) Click the [Tuning (T)] -> [Horizontal POSI. manual] menu. The following message appears.

b) Click the [OK] button on the message box. After automatic image capture, the following message appears.

c) To have the image moved left, click the [Yes] button. To have the image moved right, click [No]. tuning, click the [Cancel] button. After successful horizontal position shift and image capture, the result message appears.

To finish the

d) Go to step c) to have the image shifted right.

11.3.3. Vertical position tuning


If the captured image is shifted vertically, practice the Vertical position tuning. If the captured image has large shift, tune by the mouse. If the shift is small, tune manually. The vertical position tuning procedure is the same as that of Horizontal position tuning. Use the [Vertical POSI. Mouse] or [Vertical POSI. Manual] menu, and refer to Horizontal position tuning procedure.

143 DOC No. 7ZPNA4013D

11. Frame Grabber Board (CKA-137) Setup - FGB Utility JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

11.3.3.1. Sampling Phase tuning If the captured image is out of focus, tune the sampling phase to achieve the best sharpness. Normally, go to Phase AUTO tuning. A phase AUTO tuning is practiced on still image, stop the transmission of Radar.

a) Click the [Tuning (T)] -> [Phase AUTO] menu. The following message appears.

b) Click the [OK] button on the message box. Phase AUTO tuning start, and 35 images will be captured for tuning. During the tuning, the process is displayed on the left bottom corner. AT the end of the tuning, a result message appears.

c) Click the [No (N)] button on the message box.

144 DOC No. 7ZPNA4013D

12. OPTION System Setup


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

12. OPTION System Setup


This chapter explains how to set up the operating environment for real-time monitor system. MCB and RMB software Ver2.0.1 or later is capable of distributing the real-time data simultaneously by the multicast output setup as well as the conventional unicast distribution that specifies an output destination. First, check MCB and RMB software version, and then set it up as necessary.

12.1. Starting
12.1.1. Starting from SYSTEM Screen
In order to display OPTION system setup screen from SYSTEM screen, click [HOME] button to go to HOME screen at first.

12.2.2. Starting from HOME Screen


Option PC in Work section is the gate to the real-time monitor setup. Click the [Option PC] button on the HOME screen.

145 DOC No. 7ZPNA4013D

12. OPTION System Setup


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

12.2. Setup Procedure


1) To receive a setup data, click the [Receive] button. 2) To input the setup data, select the output data to the real-time monitor. 3) To set up IP address of RCU and Option PC, click the [Edit] button. 4) To transmit the setup data, click the [Set] button.

The setup operation of multicast is the same as that of the conventional real-time monitor except entering the IP address for simultaneous distribution.

12.3. Registration Information


Registration information entered on Log-in screen is displayed first. Then registration stored in the RCU is displayed when the configuration data is received. After setting up, the registration data is updated with the new data entered on the "Log in" screen.

12.4. IP Address
12.4.1. For Real Time Monitor
The VDR/S-VDR outputs the real time data to the specified IP address. To change the IP address, open a Network window by clicking the [Edit] button. 1) VDR-WAN port Designate the IP address of VDR-WAN port on RCU which is connected to the option PC. Default: 192.168.0.254 2) Option PC Designate the IP address of the monitor PC. Default: 192.168.0.251

146 DOC No. 7ZPNA4013D

12. OPTION System Setup


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

3) When distributing real-time data via router: In order to distribute real-time data via router to the computer in the different network from the network to which VDR is connected, check the checkbox of "Router" on the Option PC main screen. Click the [Edit] button to display the setup screen. Enter router IP address in the Next Hop field, and then click the [Set] button. Default: 192.168.0.253

12.4.2. For Multicast


VDR/S-VDR is capable of distributing data simultaneously by an assigned multicast address. When modifying the multicast address, click the [Edit] button to display the setup screen. 1) EXT LAN Check the checkbox of EXT LAN.

2Address Enter a multicast address. Default: 239.0.112.1 3Port Enter a port number. Default: 6501

Reception side should also set up the same multicast address and port number as what was set up above.

12.5. Real Time Monitor Section


Check the subject data of real time monitor.

147 DOC No. 7ZPNA4013D

12. OPTION System Setup


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual Normally, as all the data are required by the real-time monitor, all the boxes of connected channels are checked as default. 1) Sensor section Only the connected CH can be set up. Do not setup the channels of unchecked boxes. Check each channel that should output a NMEA data. The NMEA sentence data are outputted from the checked channels. 2) Audio Check AUDIO box for outputting an audio monitor data. 3) FGB1 Check FGB1 box for outputting an image monitor data from the VDR/S-VDR. 4) FGB2 The current maintenance software does not support the setup. Do not check the checkbox. 5) All Enable button When the [Enable] button is clicked, all monitor channels will be activated. With the click, all the channel boxes are checked. 6) All Disable button When the [Disable] button is clicked, all monitor channels will be deselected. With the click, all the channel boxes are undone.

Multicast output can distribute sensor data only. Check the checkbox of the CH to be output.

148 DOC No. 7ZPNA4013D

13. Report
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

13. Report
When the installation is completed, create a set of report files using this function.

13.1. Starting
1) Click the [Report] button on the SYSTEM screen. Report screen will appear.

149 DOC No. 7ZPNA4013D

13. Report
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

13.1.1. Report
Setup data, diagnosis, check result and so on can be confirmed in the Report screen. And all the contents are saved to files as service report. Since the Report files are registered in the Ship List of the Marine Service Department Home Page, send the files to the Marine Service E-mail address with the following subject. Subject : JCY-1800 Report (or JCY-1850 Report) E-mail :tmsc@jrc.co.jp 13.1.2 Report screen

150 DOC No. 7ZPNA4013D

13. Report
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

13.1.3 No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Item

Composition of Report screen Contents Ships Information VDR register information Checking of Installation Checking of setup and operation Checking of setup and operation Checking of setup and operation Checking of setup and operation Checking of setup and operation Checking of setup and operation Checking of setup and operation Checking of capsule operation Checking of blackout test Checking of Playback software Checking of Event Monitor Amendment resister information Amendment register information Check Diagnosis Entry Contents Comment Unit Info

Ships Information VDR Information Installation Sensor NSK (CH33,34) A/D VDR Radar Microphone VHF Capsule Blackout Playback Event Option PC RMS 1) 2) 3) 4) 5) 6)

Check Diagnosis Entry Contents Comment Other

: Quality judgment of operation by serviceman : Lamp indication by Diagnosis : Lamp indication by Entry check : Registered contents in VDR with Maintenance software : Comment to judgment of Diagnosis or Entry check : Detail of connected unit

Report screen is composed by 16 tab screens as shown with above table.

: Automatic input item (Registered contents with Maintenance software) : Input items in the Report screen : Comment input item

151 DOC No. 7ZPNA4013D

13. Report
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

13.1.4

Search Function There are 4 buttons for searching item of NG judgment or no entry in the Report screen. A deficient report which is not can be created by using these functions. Search target Entry Search condition When Entry lamp is: NG lamp No-entry lamp When Diagnosis lamp is: NG lamp NoteIt is excepted during diagnosis. Incase of no entry In case of no-selection Incase of NG NoteNo-comment is excepted. Measure Return the setup screen by the [System] button. And input item which is not inputted. Return the setup screen by the [System] button. And check the cause and cancel error. Input so that there is no blank. In case of no-selection, select OK or NG. In case of NG, input error cause in comment box.

No. 1

Search selection No entry lamp

NG lamp of Diagnosis

Diagnosis

3 4

No entry of Contents NG result of Check

Contents Check

Operation 1) Select any one from 4 Search selections in the Tab Selection. 2) Tab select button which is searched blinks red. 3) Click the tab select button which blinks red. Tab screen can be selected by click tab directly also. 4) Searched item is indicated by red. In order to cancel error, measure in accordance with above table.

152 DOC No. 7ZPNA4013D

13. Report
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

13.1.5

Save report file When the [Save] button is clicked, report folder is created instantly as RCU serial number (MBxxxxxx)_VDR_report on the desktop screen. Moreover setup files the other than a report files are saved as service report instantly into the report folder. Compress the report folder, and send it to the Marine Service E-mail address with the following subject. The Report files are registered in the Ship List of the Marine Service Department Home Page Subject E-mail : JCY-1800 Report (or JCY-1850 Report) :tmsc@jrc.co.jp

Saved files: Report file MCB system configuration file RMB system configuration file *1 MCB system status file RMB system status file *1 FGB setup file *1 DSC setup file *1 Event log file Radar image file *1 Sensor data file *1: In case of non-connection, the files are not saved.

Save the report file by [Save] button. If necessary, the report file can be renamed and saved.

If the report is saved, save folder, file name and creation date is indicated.

Save folder and file name

Creation date

153 DOC No. 7ZPNA4013D

13. Report
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

13.1.6

Open report file Click the [Open] button, and select report folder in the Open screen, select a report file. Contents of selected report file are indicated. If necessary, the opened report file can be and corrected. Because diagnosis is started automatically in the report screen, latest Diagnosis results are updated into the opened report file.

Select a saved report file, click the [Open] button.

Save folder, file name and creation date of opened file are indicated.

Save folder and file name

Creation date

154 DOC No. 7ZPNA4013D

14. Program update


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

14.

Program Update
Update the program of MCB, ARB RMB and FGB in the RCU according to the following instructions.

14.1. Program update of MCB, ARB and RMB


Update the program of MCB (CDJ-2304), ARB (CHA-387) and RMB (CDK-287) as follows.

14.1.1. Update application


The application for update starts from the HOME screen. Select the [RCU Update] button from the work section. 1) Click the [RCU Update] button.

155 DOC No. 7ZPNA4013D

14. Program update


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

14.1.2. Select an update program (1. Program)


1) Select a program Select an update program with the program radio button. 2) Version check Check the version of the present program. Click the [Version] button and the present version is shown. If it is the latest, program update is not needed.

14.1.3. Load a Program file (2. Program File)


Load the update program file. Click the [Browse] button, and select the update program file.

14.1.4. Check IP address and Port number (3. Port)


Verify that they are as follows. MCB, ARB: 192.168.110.3 RMB: 192.168.60.3 6000 6000

14.1.5. Update start (4. Update)


Start to update the program. Click the [Update] button. State of upload is displayed by progress bar and the message.

14.1.6. Update complete


1) Confirm that the update is completed. Check that progress bar is complete till the end. Check that [END] Update Success is displayed in the progress message

The RCU is restarted automatically and operated with the renewed program after the updating has been completed. It is not necessary to reconfigure the system following the update.

2) Check the version of the updated program. Click the [Version] button and the version will appear. 3) Quit the update application.

156 DOC No. 7ZPNA4013D

14. Program update


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

14.2. Program update of FGB


Update the program of FGB (CKA-137) according to the following instructions.

14.2.1. Preparation for FGB update


The application for update starts from the System menu on the System screen. When the "Home" screen is displayed, click the [Installation] button to move to the "System" screen.

1) FGB WEB screen Click the [FGB Setup] from the System menu on the System screen.

Internet Explorer (IE) starts and the root menu of the FGB WEB screen is displayed.

2) Put the FGB in SLEEP mode as a preparation for program update. Click the [Sleep] button on the root menu. Confirm that OK message appears.

157 DOC No. 7ZPNA4013D

14. Program update


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

3Return to the root menu Click the [Back] button

of IE, and the display screen will go back to the root menu.

* Do not click the [renew] button.

14.2.2. Starting the FGB Update application


Start the FGB update application. Click the [FGB Update] button from the System menu on the System screen.

14.2.3. Program file


Select a program file for update. Click the [Browse] button, and select the program file for update.

14.2.4. Check a IP address and Port number


Verify that they are as follows. FGB 192.168.110.151 80

14.2.5. Update start


Start to update the program. Click the [Execute] button. State of upload is displayed by progress bar and a message.

14.2.6. Update complete


1) Confirm that the update is completetd.1 Check that Application write OK is displayed in the message window. 2) Quit the update application. 2) Reboot the RCU by turning off and on the AC power. 3) Click the [renew] button on the FGB WEB root menu of the IE.

Check the updated program version.

158 DOC No. 7ZPNA4013D

14. Program update


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

14.3. Program update of Capsule


Update the program in Capsule (NDH/316/316A, NDH-317/317A) according to the following instructions.

14.3.1. Starting the capsule update application


Start the capsule update application from Home screen. Confirm the capsule model connected to VDR/S-VDR. For VDR, click the [NDH-316 Update] button or the [NDH-316A Update] button from Work section. For S-VDR, click the [NDH-317 Update] button or the [NDH-317A Update] button. 1) Click a corresponding to update button according to the capsule in use.

Software Version

2)

Update software version saved in the maintenance software is displayed on the Capsule Update"dialog. If the version is out of date, select the latest version by clicking the [Browse] button. After the select update software version is displayed, click the [Yes] button to proceed.

Note)

The Open dialog displays by clicking the [Browse] button. Select the folder where the latest update software is saved, and then update the capsule. Capsule update software file name xVR02 type: ram_XVR02_x-xx-xxx.bin xVR03 type: ram_XVR03_x-xx-xxx.bin

159 DOC No. 7ZPNA4013D

14. Program update


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

3)

The following update screen displays

4)

Confirm current software version by clicking the [Get Current SW Version] button. Software version

5)

Input a mark beside Automatic Reboot after update, and then start update process by clicking [Update Software] button.

6)

Updating status is indicated in the Status bar. When the update is completed, confirm the software version by clicking the [Get Current SW Version] button.

Updating status 7) Click the [Exit] button to close the update screen.

160 DOC No. 7ZPNA4013D

15. Playback Software Setup


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

15.

Playback Software Setup

15.1. How to play back the downloaded data from the Capsule via Ethernet
The flow from Setup to Playback is shown below. Stop recording to capsule.

Download data from capsule by the Download software.

Set information required for playback with the Setup software.

Start the Playback software.

15.1.1.

Downloading data from the Capsule by Download software


Click the [DOWNLOAD] button on the VDR INVESTGATIVE SOFTWARE launcher menu, and start the Download software.

[DOWNLOAD] button

Download screen is displayed

161 DOC No. 7ZPNA4013D

15. Playback Software Setup


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual Select a save place with the aid of Folder selection button, and then select a playlist. Once download starts, playlists (from playlist1 to playlist10) are created automatically under the save place. Saving maximum 9 download data is possible under the playlist folder except playlist1.

Folder Selection button Playlist

Set download value with the slide bar.

Note) Download data size can be specified in every 1 % with slide bar. Check the box of necessary download data and click the [Start] button. Please press [OK] button, click [Cancel] button of the download software, and end the download software.

When download starts, each download status is indicated by progress bar.

162 DOC No. 7ZPNA4013D

15. Playback Software Setup


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

When the following screen appears, download is completed. Click the [OK] button, and close the Download software with the [Cancel] button.
Download

Download was completed.

OK

NoteFolder Composition Save Place (Save Folder) Save FolderCreated by the folder name registered on the input screen ((5) section). Playlist1 Playlist2 VDR Init Log Audio Visual Event

Playlist3

Playlist10

15.1.2.

Set information required for playback with Setup software


Click the [PLAYBACK] button on the VDR INVESTIGATIVE SOFTWARE launcher menu.

[PLAYBACK] button

Click the [SETUP] button on the PLAYBACK launcher menu, and start the Setup software.

[SETUP] button

163 DOC No. 7ZPNA4013D

15. Playback Software Setup


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

The Login screen appears. Click the [OK] button after confirming that User has been clicked in the Operator block.

User

To import VDR/S-VDR configuration data, select the following file in the download data and click the [Import] button. : Playlist2VDRInitSysInfo.dat Download folder

Click the [Folder Selection] button, and select the folder created in accordance with the 3.1.3 Download data from VDR/S-VDR by Download software.

Click the [Set] button, and the setup is completed. To close the Setup software, click the [Close] button.

164 DOC No. 7ZPNA4013D

15. Playback Software Setup


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

15.1.3.
1)

Start the Playback Software


Click the [PLAYBACK] button on the VDR INVESTIGATIVE SOFTWARE launcher menu.

[PLAYBACK] button

2)

Click the [PPLAYBACK] button on the PLAYBACK launcher menu, and start the Playback software.

[PLAYBACK] button

3)

Playback screen is displayed.

165 DOC No. 7ZPNA4013D

15. Playback Software Setup


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4)

Select playback time by the Slide bar.

Slide bar

Playback button

Slide bar select button

Playback time span of the Slide bar can be selected by the Slide bar select button. 12hours: 12 hours All: All the periods of record data

Note In case of downloading from the Capsule, the record data period might be for a few days. Playback time span of the Slide bar becomes long, and so it is not easy to adjust playback time. In that case, select the 12 hours in the Slide bar select button. Playback time span becomes 12 hours; moreover, scale in every hour is displayed. So it is easy to adjust playback time.

5)

Click the [Playback] button to start playback.

166 DOC No. 7ZPNA4013D

15. Playback Software Setup


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

15.2. How to play back the CF card data


In order to play back record data of CF card, it is necessary to create a playback folder in the computer of in advance, and to copy the data. The flow from Setup to Playback is shown below. Create a playback folder at My Computer before Setup.

Set required information for playback with Setup software.

Start the Playback software, and copy the record data of CF card.

15.2.1.
1) 2)

Create a playback folder


To create a playback folder, start My Computer. Create a folder as follows. Playback data is copied to the folder made here. C:MV JRC E.g. Ships name

15.2.2.
1)

Set required information for playback with the Setup software


Click the [PLAYBACK] button on the VDR INVESTIGATIVE SOFTWARE launcher menu.

[PLAYBACK] button

2)

Click the [SETIP] button on the PLAYBACK launcher menu, and start the Setup software.

[SETUP] button

167 DOC No. 7ZPNA4013D

15. Playback Software Setup


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

3)

As the Login screen appears, click the [OK] button after confirming that User has been clicked in the Operator block.

User

4)

Eject a CF card from the VDR/S-VDR, and insert to the card slot of another laptop PC. Then, to import VDR/S-VDR configuration data, select the following file in the CF card and click the [Import] button. Note: Which drive is for CF card depends on the PC model. D: InitSysInfo.dat CF card drive as an example

5)

Click the [Folder Selection] button, and select a folder created in accordance with the 3.1 Create a playback folder.

6)

Click the [Set] button to finish the setup. To close the Setup software, click the [Close] button.

168 DOC No. 7ZPNA4013D

15. Playback Software Setup


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

15.2.3.
1)

Copy a record data of CF card


Click the [PLAYBACK] button on the VDR INVESTIGATIVE SOFTWARE launcher menu.

[PLAYBACK] button

2)

Click the [PLAYBACK] button on the PLAYBACK launcher menu., start the Playback software

[PLAYBACK] button

3)

Playback screen is displayed.

169 DOC No. 7ZPNA4013D

15. Playback Software Setup


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4)

Click the [Playlist] button on the Playback Operation Panel.

Playback button 5)

Playlist button

Verify whether or not the CF card drive is set in the Copy source. If not, click the [Folder Select] button to select the drive. Select a playlist in the Copy place and copying data volume in the Size and then click the [Copy] button. Copying volume can be selected from 1hour to 12 hours or all. If 1hour is selected, 1 hour data from the latest is copied.

6)

7) 8)

Check playlist2-Playlist10 where CF card data have been copied, then click the [OK] button. Click the [Playback] button on the playback panel to start playback.

170 DOC No. 7ZPNA4013D

15. Playback Software Setup


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

15.3. How to quit the Playback software


1) Click the [Setup] button located at the bottom right in the playback screen and the Setup screen appears.

[Setup] button

2)

Click the [Exit] button located bottom left in the Setup screen.

[Exit] button

171 DOC No. 7ZPNA4013D

15. Playback Software Setup


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

This page left blank intentionally

172 DOC No. 7ZPNA4013D

16. Remote Maintenance System Setup


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

16.

Remote Maintenance System Setup


To activate the Remote Maintenance System, set up this section as following procedure.

16.1. Log in
16.1.1. Log in to the RMS after setting up the VDR or S-VDR
Login again to Remote Maintenance System (RMS). . 1) Return to the Log in screen. Click the [Loginon the left side of screen.

2) Log in to the RMS

Select the RMS, and then click the [Next] button. The HOME screen of RMS appears.

16.1.2. Log in to the RMS first


1) Log in to the RMS

Select the RMS, and then click the [Next] button. The HOME screen of RMS appears. 2) Select the subject equipment (VDR or S-VDR).

* When the S-VDR is connected to the Inmarsat (Fleet), S-VDR will be maintained with the RMS.

The HOME screen of RMS appears

173 DOC No. 7ZPNA4013D

16. Remote Maintenance System Setup


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

16.2. HOME screen


Click the [Installation] button, and then the System screen for setup appears.

16.3. System screen


1) VDR system screen

Check box for RMS connection

174 DOC No. 7ZPNA4013D

16. Remote Maintenance System Setup


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

2) S-VDR system screen (Built-in RMB)

Check box for RMB connection

175 DOC No. 7ZPNA4013D

16. Remote Maintenance System Setup


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

16.3.1. Basic setting up procedure


The basic remote maintenance function can be set up by the following procedure. Only VDR and S-VDR with built-in RMB can collect and preserve the maintenance data from JRC equipment. The S-VDR without built-in RMB can only diagnose itself by the remote access connection.

1) Receiving configuration data Click the [Receive] button to receive configuration data. The connection setup screen of VDR/S-VDR displays. 2) Connection setup of the JRC equipment connected to VDR (For VDR/S-VDR with built-in RMB only) Check the checkbox of RMS connection channels. Usually, setup is completed only by checking.

3) Connection setup of the JRC equipment newly connected for RMS (For VDR/S-VDR with built-in RMB only) Check the checkbox of channels to additionally register the connection setup of the JRC equipment connected for RMS. Click the [Detail] button, and then the detail setup window appears. Enter the identification data and interface data of connecting equipment like setup for VDR. The sentence ID of maintenance sentence (PJRC) is inputted automatically. 4) Setting up the IP address (to VDR and S-VDR) Set up the IP address of VDR and Inmarsat (Fleet).

16.3.2. Detailed setup for serial connection


Click the [Detail] button after selecting a subject serial channel, and then the detail setup window appears. 1) Identification screen Set up identification data of connected equipment.

176 DOC No. 7ZPNA4013D

16. Remote Maintenance System Setup


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

Equipment which is set up for VDR connecting Setup is completed already, so setup data cannot be modified. Equipment which is set up for RMS connecting newly Set up identification data of equipment. Comment Enter helpful information for maintaining. The entry of a comment is not mandatory. Enter the identification data and interface data of connecting equipment like setup for VDR. The sentence ID of maintenance sentence (PJRC) is inputted automatically.

2) Data screen Set up serial interface and sentence ID of maintenance sentence.

Equipment which is set up for VDR connecting Setup is completed already, so setup data cannot be modified. Equipment which is set up for RMS connecting newly Default data is inputted automatically. Modify the default data which is not adapted to connected equipment. Sentence ID for maintenance PJRC is inputted automatically for Remote Maintenance. Some equipment may require another sentence ID. If sentence ID have to be changed, setup information will be released by the Marine service WEB. Max interval (RMS) Set the maximum time interval of receiving. If the time taken to receive a data sentence exceeds this limit, the sentence is denied and an error arises. Set a longer time when an error arises.

177 DOC No. 7ZPNA4013D

16. Remote Maintenance System Setup


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

16.3.3. Detailed setup for LAN connection


This setup is required when equipment which output a maintenance sentence via LAN is connected. At present (Feb. 2007), the equipment connected by LAN is only VDR.

1) Identification screen This screen is same as screen for serial connection.

2) Data screen Set up the LAN interface.

IP address Set up the IP address of equipment which output a maintenance sentence. (IP address: 192.168.60.xxx)

IP address table

Sentence ID for maintenance PJRC is inputted automatically for Remote Maintenance. This ID cannot be modified. Max interval (RMS) Set the maximum time interval of receiving. If the time taken to receive a data sentence exceeds this limit, the sentence is denied and an error arises. Set a longer time when an error arises.

178 DOC No. 7ZPNA4013D

16. Remote Maintenance System Setup


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

16.3.4. Network setup for RMS


Set up the IP address for connecting VDR to Inmarsat (Fleet). 1) Verify the IP address The IP address set up is displayed. Click the [Edit] button in order to test a link of LAN, then the window for Network setup appears.

VDR: 192.168.0.254 INM: 192.168.0.1

2) Link test

Click the [Start] button, and then the lamp lights in green or red as a result of test. (Green): Result of test is good. (Red): Result of test is not good.

3) Modifying the IP address Modify the IP address of VDR and Inmarsat (Fleet) when the IP address set up cannot be adapted to the Network. Test the link of LAN after modifying the IP address.

16.3.5. Starting the diagnosis function


The OK/NG of receiving maintenance data are indicated by the color of Diagnosis lamps. The meaning of each color is: (Green): OK (Red): NG (Orange): The system is under diagnosis

1) Click the [Diagnosis] button. 2) Confirm that the color of [Diagnosis] button changed to green. If the [Diagnosis] button is clicked during the diagnosis function is on, the function will be stopped.

179 DOC No. 7ZPNA4013D

16. Remote Maintenance System Setup


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

16.3.6. Downloading and viewing RMS data


This section introduces the remote maintenance data download and viewer screens. For detailed instruction, refer to Remote Maintenance Installation Manual of separate volume.

16.3.6.1. Starting RMS Viewer Click [RMS Viewer] button.

180 DOC No. 7ZPNA4013D

16. Remote Maintenance System Setup


JCY-1800/1850 16.3.6.2. Main screen 1Connected equipment information 2Reception lamp 3Alarm lamp 4Selecting download data VDR/S-VDR Maintenance Software Instruction Manual

5[Download] button 6Viewer screen start button Latest data Log data Received data

1Connected equipment information When RMS main screen is in communication (when it is opened), it acquires system configuration information from RMS and displays it. It displays the equipment connected for RMS, not for the exclusive use of VDR. 2Reception lamp When PJRC sentence (maintenance data) is being received in specified interval time, the Reception lamp indicates green. If not, it indicates red. 3Alarm lamp When the relevant equipment is operating normally, the Alarm lamp indicates green. If it is generating the error, the lamp indicates red. Acquire (Download) maintenance data of the equipment with error indication, and then analyze the root cause. * Speed LogJLN-205550: The Alarm lamp always shows in orange since it utilizes special sentence.

181 DOC No. 7ZPNA4013D

16. Remote Maintenance System Setup


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4Selecting download data Checkboxes for the following data in each CH are provided. Check the only checkbox of necessary maintenance data, and then download it. Latest dataTarget sentence: PJRCLPJRCMPJRCD The latest data of each maintenance sentence are recorded. Log data Target sentence: PJRCL The log data is recorded only if the change occurs in the content of receiving sentence data. Download it by specifying the download size (0-100%) in relation to all storage capacity of recorded data. Received dataTarget sentence: PJRCLPJRCMPJRCD All received maintenance sentence data are recorded. Download it by specifying the download size (0-100%) in relation to all storage capacity of recorded data. 5[Download] button The download of specified maintenance data starts by clicking the [Download] button. Downloaded data can be saved as a file and displayed. 6Viewer screen start button The viewer screen of downloaded data can start up by clicking viewer screen start button after the data downloading.

16.3.6.3. Selecting download data 1Individual selection Click to check each checkbox of maintenance data that you desire to download. When downloading multiple data at the same time, check all checkboxes of the data concerned. 2Package selection When downloading all maintenance data, all checkboxes can be checked together at the same time. Select All Check from View menu. As the following checkboxes display in the right side of screen, check the checkbox of necessary data classification.

Checkboxes of all pieces of equipment are checked.

3Download Click the [Download] button to start downloading the maintenance data.

182 DOC No. 7ZPNA4013D

16. Remote Maintenance System Setup


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

16.3.6.4. Viewing downloaded data 1Selecting target equipment Click the [CH**] button of target equipment to display the maintenance data viewer window.

2Selecting conversion table

Click the [Data Form] button to display the file selection dialog. As conversion file list displays, select a conversion file for the equipment concerned from the list.

3Selecting the maintenance data to be viewed

Select the maintenance data classification from menu bar. Latest Latest data LogDiff Log data LogAll Received data

183 DOC No. 7ZPNA4013D

16. Remote Maintenance System Setup


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

16.3.6.5. Latest (Latest data) The latest data of each sentence (identified by the sentence number) can be displayed. Each sentence is converted to text first, and then displayed. Data status (OK: Green lamp, NG: Red lamp Received date & time (UTC) & ships position at the time of reception (Lat / Lon)

Converted data display (CodeText

Text data display (displays received data)

184 DOC No. 7ZPNA4013D

16. Remote Maintenance System Setup


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

16.3.6.6. Log (Dif) (Log data) The recorded maintenance data displays only if the change occurs in the content of receiving maintenance data sentence. Selected sentence is converted to text first, and then displayed.

Received date & timeUTC

Ships position at the time of reception (Lat / Lon)

New

Old

Status NG MSG. No.15

Selected sentence for conversion

185 DOC No. 7ZPNA4013D

16. Remote Maintenance System Setup


JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

16.3.6.7. Log (All) (Received data All received and recorded maintenance data are displayed. Selected sentence is converted to text first, and then displayed.

Selected sentence for conversion

186 DOC No. 7ZPNA4013D

17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

17. Installation
Here the installation procedure of the maintenance software for JCY-1800 / 1850 is described.

17.1. Uninstall the old version


If the old version has already been installed, make the old version by way of the Control Panel Add/remove Programs of Windows.

17.2. Installation procedure


Download the latest version from the Marine Service WEB.

for Windows Vista When you install the maintenance software, you should log into your PC by administrator account and execute it. In that case, execute by the "Allow" of the confirmation screen. When the Setup.exe is clicked , the confirmation screen is displayed. Select the "Allow" and start installation.

Allow

187 DOC No. 7ZPNA4013D

17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

1) Perform setup.exe Double-click thesetup.exe file. 2) Start installer When the [Next >] button appears, click it after displaying the following window.

3) Input the user information Input jrcvdr into the serial number block and click the [Next >] button.

188 DOC No. 7ZPNA4013D

17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4) Installation folder As default, Program FilesJRCJCY1800Maintenance is specified as the installation folder. Click the [Next >] button.

5) Start installation Click the [Install] button to start the installation.

6) Click the [Finish] button. The installation of the maintenance software is completed.

189 DOC No. 7ZPNA4013D

17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

7) The installer of Tera Term starts continuously. Tera Term Hyper Terminal has been discontinued in Windows Vista. When the VDR IF (router) of VDR real time monitor is set up, Use the Tera Term instead of Hyper Terminal.

8) Click the [Next>] button.

9) Select "I accept the agreement", and click the [Next>] button.

10) Click the [Next>] button.

190 DOC No. 7ZPNA4013D

17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

11) Select the "English", and click the [Next>] button.

12) Click the [Next>] button.

13) Click the [Next>] button.

14) Click the [Install] button.

191 DOC No. 7ZPNA4013D

17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

15) Click [Finish] button.

16) Installation of the Tera Term is completed The icons of the JCY-1800 Maintenance software and the Tera Term software are created on the desktop.

192 DOC No. 7ZPNA4013D

17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

17When Windows Vista PC is used, it is necessary to continue and to cancel UAC (user account control). Cancel it according to the following operations. Right-click in the JCY-1800 Maintenance" icon on the desktop.

Select Properties.

Properties Select the Compatibility tab.

Compatibility tab

193 DOC No. 7ZPNA4013D

17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

Input a "" mark in "Run this program as an administrator" of "Privileged level", and click the [OK] button.

Privileged level

The setup for the Windows Vista is completed.

For Windows Vista When you use the maintenance software, you should log into your PC by administrator account and execute it. In that case, execute by the "Allow" of the confirmation screen.

Allow

194 DOC No. 7ZPNA4013D

17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

17.3. Language setting of maintenance PC


If the operating system (OS) on your PC is not Japanese or English version, Maintenance software might not works correctly. Please set language to the "English (United States) or the English (United Kingdom) as follows. For Windows XP 1) Click the "Date, Time, Language, and Regional Options" on the Control Panel screen.

Clock, Language, and Region

2Click the Regional and Language Options.

Clock, Language, and Region

195 DOC No. 7ZPNA4013D

17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

3Select the "Regional Options" tab, select the "English (United States)" or the "English (United Kingdom)".

Regional Options tab

English (United States) or English (United Kingdom)

4) Select the "Advanced" tab. Select the "English (United States)" or the "English (United Kingdom)", and then click the [OK] button. You will be asked to restart Windows, and then restart it.

Advance tab

English (United States) or English (United Kingdom)

196 DOC No. 7ZPNA4013D

17. Installation
JCY-1800/1850 For Windows Vista 1 Click the Clock, Language, and Region on Control Panel screen. VDR/S-VDR Maintenance Software Instruction Manual

Clock, Language, and Region

2 Click the "Regional and Language Options".

Regional and Language Options

197 DOC No. 7ZPNA4013D

17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

3 Select the "Formats" tab, select the "English(United States)" or the "English(United Kingdom)",

Format tab

English (United States) or English (United Kingdom)

4 Select "Administrator" tab. Click the [Change system locale] button, and select the "English (United States)" or the "English (United Kingdom), and then click the [OK] button. You will be asked to restart Windows, and then restart it.

Administrator tab

[Change system locale] button

198 DOC No. 7ZPNA4013D