RECORD OF REVISIONS
Rev 1.0 1.1 2.0 A First edition Revised 13.Report Setup for Remote Maintenance is added. Setup for NAV-I/F unit is added. Document Code is revised 7ZPNA4013A Registration method of VHF installation place was added. Operation method of conversion software was added. Language setup was added. Document Code is revised 7ZPNA4013B. Conforms to Windows Vista Document Code is revised 7ZPNA4013C. Note about the speed improvement of configuration data reception process by [Receive] button was added. The method for additionally installing RMB was added. RMS Setup method was changed. RMS Viewer operation instruction was added. Multicast setup method for VDR real-time output was added. Download method for the latest data from CF card was added. The operation method for opening configuration file was modified. The method for updating Capsule software was added. Document Code is revised to 7ZPNA4013D. Description Date 17-Oct.-06 19-Jan-07 17-Feb-07 9-Apr-07
20-May-08
28-Oct-08
8-May-09
JCY-1800/1850
JCY-1800/1850
TABLE OF CONTENTS
1. 2.
2.1. 2.2.
Maintenance Software ................................................................................................................... 1 Starting and Quitting the Maintenance Software ........................................................................ 3
Starting the Maintenance software ............................................................................................................................3 Quitting the Maintenance software............................................................................................................................5
3.
3.1. 3.2.
4.
4.1. 4.2. 4.3. 4.4. 4.5. 4.6. 4.7. 4.8. 4.9. 4.10. 4.11. 4.12.
5.
5.1. 5.2. 5.3. 5.4. 5.5. 5.6. 5.7.
6.
6.1. 6.2. 6.3. 6.4. 6.5.
7.
7.1. 7.2. 7.3. 7.4. 7.5.
8.
8.1. 8.2. 8.3. 8.4. 8.5.
JCY-1800/1850
9.
9.1. 9.2. 9.3. 9.4. 9.5. 9.6. 9.7.
10.
10.1. 10.2. 10.3.
Playback...................................................................................................................................... 133
Starting.....................................................................................................................................................................133 Playback Software...................................................................................................................................................134 Check the recorded data .........................................................................................................................................134
11.
11.1. 11.2. 11.3.
12.
12.1. 12.2. 12.3. 12.4. 12.5.
13.
13.1.
Report.......................................................................................................................................... 149
Starting.....................................................................................................................................................................149
14.
14.1. 14.2. 14.3.
15.
15.1. 15.2. 15.3.
16.
16.1. 16.2. 16.3.
17.
17.1. 17.2. 17.3.
1. Maintenance Software
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
1. Maintenance Software
The maintenance software of JCY-1800/1850 is a PC-based application. The original task of the software is to check the equipment and to create the As-delivered software configuration. On board a ship, this is a versatile tool for a service engineer, too. The software helps him to install the equipment, reconfigure the setting, carry out the operation check and locate the fault, if any. 1) Software name: JCY1800-maint.exe 2) Language used: English 3) Characters used for entry: English one-byte characters only The number of characters that can be inputted is limited by each entry field. Entry over the maximum allowable number is denied. 4) Installation of the maintenance software: Use setup.exe for installing this software to the maintenance PC. Refer to Chapter 16 for the installation of this software.
For Windows Vista It is necessary to release UAC (user account control) for Windows Vista. Please install it according to the procedure of "Installation" in Chapter 17. When UAC has not been canceled, it is not possible to operate normally.
5)
6)
PC: A laptop that meets the following or higher requirements: :Windows XP / Vista (SP1 or after it) OS :1GHz or more CPU Memory :512Mbytes or more(XP) : 1Gbytes or more(Vista) :CF card as a data backup medium of VDR/S-VDR PCMCIA card slot (A delivered card adapter is attached to the RCU.) :Ethernet (10/100Mbps) Communication I/F :1024768 (XGA) or more Screen resolution :Small size font only Display font
1. Maintenance Software
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
7)
Personal Firewall In case a personal firewall is run on the PC, suspend the function before using the maintenance software. Personal Firewall A personal firewall is a filtering facility of LAN communication link attached to OS (Windows XP, Vista) and the software to detect and isolate a virus. When a personal firewall is enabled; The VDR/S-VDR cannot communicate with the maintenance PC.
8)
Other requirements for maintenance: LAN cable (Built in the RCU.) Makes LAN connection from the Maintenance PC to the HUB unit of the RCU.
-------------- ABBREVIATIONS --------------Some of the abbreviations commonly used in this manual are: Abbreviations HVR/SVR RCU MCB FGB ARB RMB OPU DSC ACB Name of the Unit Capsule Recording Control Unit Main Control Board Frame Grabber Board Audio Recording Board Remote Maintenance Board Operation Panel Unit Digital Signal Converter (64CH/16CH) Analog Signal Convert Board (DSC option) Code NDH-316317 NDV-18001850 CDJ-2304 CKA-137 CHA-387 CDJ-2143 NCG-169 NCT-7263 CEF-60
2.1.2.2. Entering User name, Company name and Password (Register Information)
1) Register Information Enter the following user information, which will be recorded onto the VDR/S-VDR. User name Company name
2) Password The entered letters are indicated with asterisks (******). This is the password for field engineer. All "jrcvdr" is small letters.
2.1.2.5. Login
Click the [Next] button. After successful login to the VDR/S-VDR, HOME screen will appear.
The maintenance software is shut down after logging out from the VDR/S-VDR.
Operation button
Work buttons
3.2.2. Playback
Select Playback for checking the recorded data on the VDR/S-VDR. The Playback software will be activated.
Update of FGB program can be performed from the menu of SYSTEM screen.
[Installation]
To configure the VDR/S-VDR, click the [Installation] button. The SYSTEM screen for the selected system (VDR/S-VDR/RMS) at log-in will appear.
JCY-1800
JCY-1850
Receive button
4.2.1 4.3.1 4.4.1 4.5.1 4.6.1 4.7.1 4.8.1 4.3.2 4.4.2 4.5.2 4.6.2 4.7.2 4.8.2
3 4 5 6
Setting a detail information Transmitting a system configuration data to the RCU Setting up the System Rebooting the RCU Checking the diagnostic results
Each Detail button Set button in each detail window Repeat Step3 and Step4 Reboot button Diagnosis button and lamp Real time monitor
7 Receiving data
Return to STEP3
9 10 11
Report folder is created on the Desktop of the PC automatically. Compress the folder, and upload the compressed files to the Ship list on the Marine service WEB.
2) Confirm the reception has been completed with the progress bar.
The configuration data reception process by [Receive] button is improved to high-speed for MCB and RMB software Ver2.0.1 or later. As a result, the data can be received instantly. Note that the earlier software version is not compatible for high-speed reception, so that it takes time as before.
2) Confirm that the color of [Diagnosis] button changed to green. * If the [Diagnosis] button is clicked during the diagnosis function is on, the function will be stopped.
Caution)
Cross out the check mark in the check box when the sensor connection setup is to be undone (from enable to disable) temporarily. In this case, do not forget to delete the setup data referring to 4.3.3.3. If the setup data remains when the mark is removed from the check box, the data from the same sensor may not be recorded via other channel.
Select a recording item from the pull-down menu. Click the [Next] button.
Select Other, when there is no appropriate item that should be set up. Enter an appropriate data for connected equipment on "Data" tab screen.
Caution) In case the recording data item to set up is not displayed: Subject recording data is already registered in other channel(s). Clear the setup of CH registered. Setting data are not cleared simply by changing the setting from enable to disable. Refer to the following procedure for deleting setup data.
To change the detail setup data registered; Choose No (Default) of radio button and click the [Next] button. To change the selected Recording item and selected Equipment; Click Yes of radio button and click the [Next] button. To clear the setup data; Click Do you want to delete information? and click the [Next] button.
2) Setup procedure Delete the setup data of the CH4 according to the aforementioned. Check the check box of CH33. Enter setup data for receiving the heading data into detail window of CH33.
Selection table
Recording item Date & Time/Ship' Position Equipment GPSMain) ID 41 Recording data Date and Time Ship's Position Local Geodetic Datum(DTM) GPS(Main+Sub) 71 Date and Time Ship's Position Local Geodetic Datum(DTM) GPS(Sub) 72 Other Other Other Ship's Speed Ship's Heading Depth Speed Log Gyro Compass Magnetic Compass Echo Sounder(Bow) Echo Sounder(Stern) Wind Speed and Direction Rudder Order/Response Anemometer Autopilot Rudder Angle Indicator ECDIS Engine Order/Response M/E Remote Control System Engine Telegraph Thruster Order/Response Thruster Bow1 Thruster Bow2 Thruster Stern1 Thruster Stern2 Thruster Acceleration and Hull Stress Door Status Fire Door Status Watertight Door Panel Hull Door Control Ramp Way Indicator Main Alarms Alarm Monitoring system Water Ingress Alarm System Bilge Alarm Panel Fire Detection System Steering Gear AIS Data AIS * * * 42 AIS VDO Data AIS VDM Data Status Information Main Alarm(ALR) Radar Selection Other RadarMain) 58 * Radar Selection Other ??VDO ??VDM ??TXT ??ALR ??PJRC * * * * * * Fire Door Status Watertight Door Status Hull Door Status ??DOR ??DOR ??DOR Hull Stress Monitor 49 52 53 54 55 56 57 47 59 48 45 46 51 50 43 44 Ground/Water Speed Ship's Heading Ship's Heading Depth Other Wind Speed and Direction Rudder Order, Manual Rudder Response, Manual Rudder Response, Manual Rudder Order, Automatic M/E RPM Set Order(CPP order) M/E RPM Actual Response(CPP order) Telegraph Order Position Thruster Response Thruster Response Thruster Response Thruster Response Thruster Response Hull Stress Sentence ID ??ZDA ??GGA ??GNS ??DTM ??ZDA ??GGA ??GNS ??DTM ??ZDA ??GGA ??GNS ??DTM ??VBW ??HDT ??HDG ??DPT ??DPT ??MWV ??HTD ??RSA ??RSA ??HTC ??PRC ??RPM ??ETL ??TRD ??TRD ??TRD ??TRD ??TRD ??HSS ??RMCV ??RMC ??RMCV ??RMC ??RMC ??GLL ??RMCV
Equipment DSC (CH13) DSC (CH14) DSC (CH15) DSC (CH16) DSC+A/D (CH13) DSC+A/D (CH14) DSC+A/D (CH15) DSC+A/D (CH16) NAV-IF (NCT-52A) NAV-IF (NCT-**)
ID 60 61 62 63 64 65 66 67 68 69
Recording data Dry Contact Data (CH13) Dry Contact Data (CH14) Dry Contact Data (CH15) Dry Contact Data (CH16) Dry Contact Data (CH13) A/D Convert Data (CH13) Dry Contact Data (CH14) A/D Convert Data (CH14) Dry Contact Data (CH15) A/D Convert Data (CH15) Dry Contact Data (CH16) A/D Convert Data (CH16) NAV-I/F Data(Option Unit) NAV-I/F Data(Option Unit)
Sentence ID ????? ????? ????? ????? ????? VRXDR ????? VRXDR ????? VRXDR ????? VRXDR ANADAT ANADAT
4) Serial No. Enter the serial number of the connected equipment. * If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial No. column.
4.3.4.2.2. Communication parameters and Sentence format Set the communication parameter and the sentence format. Once the type is selected, following parameters are automatically set as default. There is no need to change these values.
TYPE Baud Rate Data Bits Stop Bits Parity Checksum Header Delimiter Max Length Max Interval
1)
Header Enter the header character. Enter $ for general sensor units. In case of connecting to the AIS, enter ! as a header character. When ! is entered, the RCU receives the NMEA sentences that have $ and ! as header. Delimiter Enter delimiter (the sign that means the end of the sentence). OD OA is recognized by the software as <CR><LF>.
2)
3) Maximum length of sentence Set the maximum length of the data sentence. Any data sentence of which length exceeds this maximum sentence length is denied and an error is arisen. The maximum length of the NMEA sentence is 82Bytes. 4) Maximum time interval of receiving Set the maximum time interval of receiving. If the time taken to receive a data sentence exceeds this limit, the sentence is denied and an error arises. For example, suppose ZDA, DTM, and GGA are set to be received. If the time taken to receive all ZDA, DTM and GGA exceeds the maximum time interval, all the information is denied and an error is raised.
In case of NMEA sentence: The talker ID (2 characters) can be entered along with the sentence ID (3 characters). An uncertain character also can be entered using ?. Enter as many characters as you like (up to 7 characters). At least, include the sentence ID (3 characters). Examples: setting sentence ID for filtering ZDA sentences of GPS. ( all OK ) GPZDA GPZDA?? ??ZDA ??ZDA??
In case of option unit sentence: A/D : VRXDR DSC (NCT-72/63): ? (Since all sentences are recorded, "?" is used as a wildcard.)
3) Watch The watch on maximum interval of receiving can be set on each sentence. Set the Watch function of each NMEA sentence to enable or disable. The VDR/S-VDR will generate an error when the NMEA sentences set as Enable are not received within the set interval time. The VDR/S-VDR will not generate the error alarm when the NMEA sentences set as Disable are not received within the interval time. Enable: [ ] (checked) Disable: [ ] (unchecked) When the NMEA sentence ID is registered, checks will be entered as a default. In case of setting to disable On the equipment that does not transmit NMEA sentences periodically, the setting shall be Disable. Enable does make sense on the equipment that transmits sentence(s) periodically.
(Green): (Yellow):
All entries are made. Blanks still remain. Look for a blank item and input a setup data.
Click the [Start] button. * Real time monitor is automatically started at the opening window. Click the [Stop] button.
STOP:
2) Selecting the monitor data type. Click the radio button of data type (RCV Data /REC Data) to monitor.
RCV Data: Monitors all the data that the RCU receives. REC data:
The sentence data which is not recorded on the VDR/S-VDR is also displayed. Monitors the sentence data which is recorded in the VDR/S-VDR. The sentence which is not recorded is not displayed even when it has been received. The monitored data is displayed by the sentence format currently recorded in the VDR/S-VDR.
The VDR/S-VDR receives a recording data The VDR/S-VDR does not receive a recording data. Check a receiving data by real time monitor. Under diagnosis
* To have the diagnostic function operated, click the [Diagnosis] button on System screen. If the function is not on, the Diagnosis lamp is off.
4) Serial No. Enter the serial number of the connected equipment. * If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial No. column. 4.3.5.1.2. Antenna position Enter the following values for antenna position. Distance from Bow/Stern/Port side/Starboard side to the antenna
1)
Switch position Select the logic of dry contact signal which is outputted by a GPS switcher. The GPS switcher is connected to TB406 PI-3 which is a terminal in the RCU. The VDR/S-VDR records the GPS equipment (main or sub) currently recorded as EVENT.
1) Date and Time The sentence of Date and Time data is "ZDA" as default. When the GPS does not output ZDA, change the sentence to "RMC" instead. 2Datum When the GPS does not output DTM, clear the DTM setting.
4) Serial No. Enter the serial number of the connected equipment. * If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial No. column.
4.4.3.2.
4.4.3.2.2. Ratio Select turn ratio from 1, 36, 90, 180 or 360 deg.
4.4.3.2.3. Gray Code Select Order Direction or Reverse Direction as rotation direction.
(Caution)
When the setup data of "Signal Type", "Ratio", or "Gray Code" are changed, transmit the setup data to RCU before inputting an initial value of heading. Click the [Set] button, to finalize the renewed data. * After the data transmission, RCU is rebooted automatically and setting data will become effective.
4.4.3.2.5. Heading Data Even when the entry of heading angle is not made from OPU, the initial value of heading can be inputted from Heading TAB screen.
1) Measured Value The current value of heading is displayed. The value displayed on this screen is the same as the value displayed on OPU. * Hading value is not displayed if the Real-time monitor has been stopped. Start the Real-time monitor in "Rec data" mode.
2) Initial Value Click the [Send] button after inputting an initial value. The inputted initial value is registered into the RCU. * "Initial Value" and "Measured Value" should show the same heading value immediately after the screen is opened. When the correct heading value is displayed, click the [Send] button without inputting an initial value.
3) Checking the heading value Check that the correct heading value is displayed on the "Measured Value".
4) Serial No. Enter the serial number of the connected equipment. * If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial No. column.
4.4.4.2.
4.4.4.2.1.
Pulse
Select Option Unit from the pull-down menu. Then click the [Next] button.
Select connected equipment from the pull-down menu. In case of connecting dry contacts Select the DSC (CH*). In case of connecting dry contacts and analog signals Select the DSC+A/D (CH*) (Optional Analog Conversion Board (CEF-60) must be built in the DSC.) Click the [Next] button.
DSC+A/D
DSC
4.5.5. Detail setup window of dry contact (Dry Contact TAB screen)
This is the screen for transmitting and receiving the configuration file of NCT-72/63.
Dry contact data, such as alarm, door (open or close) and others should be changed into NMEA sentences. The screen for creating conversion table file will appear.
In editing not the configuration file that was received from NCT-72/63 but the configuration file saved, point to Open at File menu list.
4.5.5.4.1. Registration of sentence data converted from dry contact signal Sentence data are set up to each channel which accepts dry contact signal.
1) Alarm Select the inputting dry contact state (OPEN/CLOSE) when the connected equipment is in normal state.
2) Door Select the inputting dry contact state (OPEN/CLOSE) when the connected door is open.
* A selection setup from a tree structure The tree structure displayed on the left screen shows the dry contact inputs that can be registered. Sentence data can be set up by double-clicking each item.
2) Identification number of a dry contact A signal of the same kind must be identified by respective number. Select the identification number listed in the pull-down menu. Be careful not to double select an identification number otherwise the same sentence data will be created
3) Comment Each sentence can be followed by a comment. Add a comment to each sentence by which a service engineer recognizes what the signal is.
3) Registering sentence data Click the [SET] button when all categories are selected and comment is inputted. The sentence is created according to the contents of selection and is added to the setup file.
4.5.5.4.2. Deleting and editing a sentence data registered The sentence registered into the setup file can be deleted. 1) Selecting a sentence Double-click the sentence displayed on the list. The CH number for deletion is displayed. 2) Deleting a sentence Click the [Delete] button. 2) Editing a sentence Set up a new sentence data after deletion.
4.5.5.4.3. When All Setup is Completed When there is no connection to Engine telegraph, move on to the 4.5.5.6.
4.5.5.5.2. Engine telegraph position Setup an engine telegraph position data according to the following procedure.
1) Selection of Enable / Disable Select either Enable (connected) or Disable (disconnected) of the engine telegraph position data by dry contact signals. In case of connecting, click the checkbox.
2) Selecting the connected dry contact signals On the selecting menu, all the signals of an engine telegraph position can be registered. The contact signal actually connected must be all selected. Check the connection signal.
3) Selecting the connection CH Select the connection CH of NCT-72/63 from the pull-down menu.
4) Selecting the state of dry contact signal Select a state of the dry contact signal (Open/Close) at "Active state".
2) 4) 3)
4.5.5.5.3. Sub telegraph position Set up a sub telegraph position data. Setup procedure is the same as Engine telegraph position.
4.5.5.5.4. Operation position Set up an operation position data of engine telegraph. 1) Selection of Enable / Disable Select either Enable (connected) or Disable (disconnected) of the operation position data by dry contact signals. In case of connecting, click the checkbox.
4.5.5.5.5. Order or Response (Status) Select the sentence type (Order / Response) of engine telegraph signals.
4.5.5.5.6. Engine and Propeller position Select the position of the engine and the propeller shaft. Single or on center line Port Starboard
4.5.5.5.7. Registration of Engine telegraph sentence data The NMEA sentence for engine telegraph is registered. 1) ETL sentence identification number Select the identification number in case of registering two or more ETL sentences. When registering only one sentence, "01" as a default must be selected. To register two or more sentences, select the total number. It can set up from "01" to "04."
2) Registering sentence data Click the [SET] button. The ETL sentence is registered.
1) Transmit the configuration file. Click the [Send] button. 2) The setup screen is completed and returns to the Transmit/Receive screen of the configuration file. The configuration file is transmitted automatically to the NCT-72/63. 3) Save the configuration file To save the configuration file of NCT-72/63, it should be saved before transmitting the file. Click the [Save As] button, and save the configuration file.
4.5.5.8.1. Real Time Monitor The NMEA sentence can be monitored by the real time monitor on the setting screen. If the following dry contact signal monitor is available, check the sentence with this.
1) Dialog for entering a diagnostic result Click the [DSC Check] button. The dialog for entering a diagnostic result will appear.
2) Connection of dry contact signals Check that monitor icons (lamp, door) change according to the state of the connected dry contact signals. Enter the diagnostic result using the radio button (Good/No Good). 3) Sentence setup Check that the logic of a dry contact signal is correct. Alarm Normal: Green lamp / Abnormal: Red lamp Door A door icon shows the state of door (Open/Close). Click Good or No Good according to the diagnostic result. 4) Comment Enter a comment if the result is NG.
The following data that are inputted on the setup screen of each channel are displayed on this screen. Connection signal Current value Data unit
4.5.6.2.1. Identification of Analog signal output Equipment Set an information data of connected Analog signal output equipment. 1) Equipment Enter the name of the connected equipment. 2) 3) Model Enter the model name of the connected equipment. Manufacturer Enter the name of the manufacturer of the connected equipment.
4) Serial No. Enter the serial number of the connected equipment. * If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial No. column.
4.5.6.2.2. Setup of Analog signal Specifications Type of signal (Voltage or Current), range and etc. are set by the strap on PCB (ACB: CEF-60). Maintenance software has no effect on them. 4.5.6.2.3. Calculating a coefficient Set up the parameters to translate the A/D conversion value (%) of the ACB into the real value displayed on the equipment. 1) Selecting CH Select an analog channel to set up.
2) Setting a minimum value Operate the analog signal output equipment so that it will output the minimum value. STEP1: STEP2: Input the minimum value displayed on the equipment. Input the A/D conversion value. Click the [Receive] button. A/D conversion value is inputted automatically. * Manual input is also possible. Click the [Set] button.
STEP3:
3) Setting a maximum value Operate the analog signal output equipment so that it will output the maximum value. STEP4: STEP5: Input the maximum value displayed on the equipment. Input the A/D conversion value. Click the [Receive] button. A/D conversion value is inputted automatically. * Manual input is also possible. Click the [Set] button.
STEP6:
4) Verify the calculated data Check the conversion formula is correct. STEP7: Check that the conversion value on Check value and the real value on the equipment are the same. Click the [Check] button. The converted value is displayed. When the converted value is not correct, repeat from STEP1. Set the coefficient of the formula. Click the [Apply] button.
STEP8:
Language setting If the Maintenance PC is not Japanese OS or English OS, analog data may not convert real value correctly, depending on language. Please set language to the English (United States or the English (United Kingdom) in the Control Panel screen of Windows. Refer to "17.3 Language setting for Maintenance PC" about the setting method of language.
4.5.6.2.4. Setting of Analog signal information The specification and information of the analog signal are set up.
2) Contents of connection data Select the contents of connection data. 3) Conversion formula The coefficients of the conversion formula are inputted automatically. * Manual input is also possible.
Conversion formula y=A1*10A2x+B1*10B2 y=Equivalent, x=A/D conversion value, A1, A2, B1, B2: Coefficient
4) Analog signal range Select the analog signal input range. This entry has nothing to do with analog-digital conversion. This is simply a record of input condition.
4.5.6.2.5. Setting detail setup of Analog signal Set up the data after completing all setup. Click the [Set] button.
1) Dialog for entering a diagnostic result Click the [A/D Check] button. The dialog for entering a diagnostic result will appear.
2) Connection of analog signals Check that the A/D-conversion value of the connected analog signal is recorded. Enter the diagnostic result to radio button (Good/No Good). 3) Sentence setup Check that the conversion value is an appropriate value. Click Good or No Good according to the diagnostic result. 4) Comment Enter a comment if the result is NG.
1) Setting parameter of each channel Items Input channel use Input signal Range Parameter YES (enable) / NO (disable) Voltage 1V 5V 10V Current 4-20mA Remark Select YES for connecting analog signal or NO for not connecting signal. Chooses the type of signal. Chooses the range of input signal. Set up the range according to the type of signal.
CH0
CH1
CH2
CH3
CH4
CH5
CH6
CH7
Select Option Unit from the pull-down menu. Then click the [Next] button.
Select connected equipment from the pull-down menu. In case of connecting NCT-52A Select the NAV-I/F (NCT-52A).
NAV-I/F
Set an identification data of NCT-52A. 1) Equipment "NAV-I/F" is entered automatically. 2) 3) Model "NCT-52A" is entered automatically. Manufacturer "JRC" is entered automatically.
CH1
Set an information data of rudder angle output equipment. 1 Contents "Rudder" is entered automatically. It cannot be modified. * Synchro signal for rudder angle has to be connected to the CH1 of NCT-52A. 2) Equipment Enter the name of the connected equipment. 3) Model Enter the model name of the connected equipment.
4)
5) Serial No. Enter the serial number of the connected equipment. * If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial No. column.
CH2
Set an information data of wind direction output equipment. 1 Contents "Wind Direction" is entered automatically. It cannot be modified. * Synchro signal for wind direction has to be connected to the CH2 of NCT-52A. The following items are same as that of ch1 setting.
CH3
Set an information data of wind speed output equipment. 1 Contents "Wind Speed" is entered automatically. It cannot be modified. * Analog signal (1-5V or 4-20mA) for wind speed has to be connected to the CH3 of NCT-52A. The following items are same as that of ch1 setting.
"Rudder angle", "wind direction", and "wind speed" data from NCT-52A are displayed on real time. Verify the converted value after all setup. When the converted value is not correct, retry a setup of parameters.
Rudder Setting
Step 1) Step 2) Step 3) Step 4) Step 5)
Set the parameters for converting Synchro signal to rudder angle data. Control the actual rudder, so that the rudder angle value is set to "00.0." Select ratio from x2, x3, x4 or x5. Click the [Initialize] button. Wait for 5 seconds until initializing of NCT-52A is completed. Click the [Adjust] button. Verify that the correct rudder angle value is displayed on the Check value.
NAV-I/F data
The setup parameters to NCT-52A are displayed. Click the [Read] button. Each setup parameters are displayed.
Set the parameters for converting Synchro signal to wind direction data.
Step 1) Control the anemometer to stabilize the value of the wind direction. Step 2) Select direction from Order or Reverse. Step 3) Click the [Initialize] button. Wait for 5 seconds until initializing of NCT-52A is completed. Step 4) Input a wind direction value displayed on the anemometer. Step 5) Click the [Adjust] button. Step 6) Verify that the correct wind direction value is displayed on the Check value.
NAV-I/F data
The setup parameters to NCT-52A are displayed. Click the [Read] button. Each setup parameters are displayed.
Set the parameters for converting Analog signal (1-5V or 4-20mA) to wind speed data.
Step 1) Input a wind speed value on 1V (or 4mA) anemometer outputting. Step 2) Input a wind speed value on 5V (or 20mA) anemometer outputting. Step 3) Click the [Adjust] button. Verify that the correct wind speed value is displayed on the Check value.
Language setting If the Maintenance PC is not Japanese OS or English OS, analog data may not convert real value correctly, depending on language. Please set language to the English (United States or the English (United Kingdom) in the Control Panel screen of Windows. Refer to "17.3 Language setting for Maintenance PC" about the setting method of language.
NAV-I/F data
The setup parameters to NCT-52A are displayed. Click the [Read] button. Each setup parameters are displayed.
Sentence format
$ANADATA, Rudder angle data, Wind direction data, Wind speed data
2) Receiving sentence data from NAV-I/F Check that the ANADATA sentence data from NAV-I/F is recorded. Enter the diagnostic result to radio button (Good/No Good). 3) Converting value Verify that the converting value is correct. Enter the diagnostic result to radio button (Good/No Good). 4) Comment Enter a comment if the result is NG.
2) Frame Grabber Board (FGB) S-VDR (JCY-1850) FGB is an option board in the S-VDR. Therefore the default setting of FGB is disable. When the FGB is installed into the RCU, Check the check box of FGB VDR (JCY-1800) VDRJCY-1800 FGB is a standard board in the VDR. Therefore the default setting of FGB is enable and the check cannot be cancelled.
1) 2)
Model Enter the model name of the connected equipment. Manufacturer Enter the name of the manufacturer of the connected equipment.
3) Serial No. Enter the serial number of the connected equipment. * If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial No. column.
4.7.3.1.2. Setup file of FGB The setup file of FGB can be downloaded and uploaded. The setup file of FGB is saved in the FGB_UtilCKA137-JCY1800 folder hung under Install folder of the maintenance software. The Radar model or image specification is used as the file name. Select a correct setup file referring to the following instructions.
Radar model
Cap2-JMA9900-1800.txt Cap2 "2" means this setup file is for FGB: CKA -137. Reference: When Cap is not suffixed by 2 (i.e; Cap-..), the setup file is for CKA-129. JMA9900 Radar model 1800 1800 means the setup file is for JCY-1800/1850. Reference: 1700 stands for JCY-1700/S.
VESA
Cap2-1024x768-60Hz-1800.txt Cap2 "2" means this setup file is for FGB: CKA -137. Reference: When Cap is not suffixed by 2 (i.e; Cap-..), the setup file is for CKA-129. 1024x768 Image Resolution 60Hz Refresh rate 1800 1800 means the setup file is for JCY-1800/1850. Reference: 1700 stands for JCY-1700/S.
4.7.3.1.3. Two Radar images recording mode This is the recording mode applied when two radars are hooked up to the VDR/S-VDR. 1) Recording single image switching two radars This is called switching record mode, Standard recording method. Select the Single Record by Switch from the pull-down menu.
2) Recording both images The dual record mode can be selected as an option. To adopt the option, larger storage of memory of Capsule and CF card is required. Both Radar images can be recorded at a time with the extended memory. Select Dual Record from the pull-down menu.
4.7.3.1.4. In case of using Radar Interface Unit The Radar Interface Unit should be installed, when the display resolution of connected Radar unit is UXGA. 1) Setting the mode of Radar interface unit When the Radar Interface Unit is installed, select the NWP-46 from the pull-down menu. Enter the serial number of NWP-46. *Caution: The Radar interface unit has a cooling fan. In case None is selected, Fan alarm is not informed even when the alarm arises.
4.7.3.2.1. Select signal When two radars are connected and VDR/S-VDR records one of the two radar images by switching, set the switching signal. 1) Dry contact Select Dry contact, when recording channel is switched by dry contact signals outputted from a switcher. 2) NMEA Select NMEA, when recording channel is switched by the PJRC sentence outputted from JRC radar. 3) None (Auto) Select None, when the switching signal is not connected. Recording channel is switched by detecting a RGB signal. When radar images are sent from both radars, the image on CH1 is recorded.
4.7.3.2.2. NMEA Sensor channel which receives PJRC sentence for switching is set up automatically. Verify that a Radar connection channel is displayed.
4.7.3.2.3. Dry Contact Select the logic of the dry contact which is outputted by a switcher. AUTO mode is selected when both dry contact signals are of the same logic. Logic table of dry contact PI_1 OPEN OPEN CLOSE CLOSE
2) Starting to monitor START: Click the [Start] button. STOP: Click the [Stop] button.
3) Diagnosis Have a look the radar picture and judge the quality by yourself. Then click the [Image Quality check] button. Sort the acceptable or better picture to Good and the questionable or worse to No Good.
Judging the image quality. Click Good or No Good accordingly. If the latter is the case, write a comment.
* Click the [Help] button to have an advice on judging the Image quality.
* When a location gap of recording image exists or the focus of recording image is poor, adjust the value of the configuration file of the FGB referring to Chapter 11.
(Green): (Yellow):
All entries are made. A blank remains. Look for the blank item and input the setup data.
2) Image Quality lamp Result of judgment on the image quality is indicated by the Image Quality lamp.
The image quality is not judged yet. Open the "Image quality check" screen and enter the result of judgment. The image quality is judged good. The image quality is judged no good.
* Setting of modified data of the "Radar" section is validated after the reboot of RCU. Therefore, when a setup data is changed, do not refer to the diagnostic result made before rebooting the RCU. * The diagnostic lamp is displayed also on the SYSYTEM screen. Click the [Reboot] button on the SYSTEM screen after completing setup, and check the diagnostic lamp of the SYSTEM screen. The meaning of each lampis; 1) FGB The Ethernet communication link condition of the Frame Grabber Board (FGB) and the Main Control Board (MCB) 2) Main The RGB signal from the main radar 3) Sub The RGB signal from the sub radar
* The diagnostic function needs to be in operation. A "Diagnosis" lamp becomes a blank display when the diagnostic function is not operating. A diagnostic function can be started with the [Diagnosis] button on SYSTEM screen.
Caution:
Audio data is a mixture of triple input from each Microphone. correctly working, connects only one Microphone to monitor.
1) Selecting the monitor CH Select a monitor channel with a radio button. 2) Starting monitor START: Click the [Play] button. STOP: Click the [Stop] button. 3) Volume Adjust the sound volume by a slide bar. Caution: When sound does not come out from the loudspeaker, check whether or not the speaker output of PC is OFF or sound volume is minimum.
4) Diagnosis Listen to the audio and judge the quality by yourself. Click the [Audio Quality check] button. Judge the audio quality on microphone 1-3, 4-6 and 7-9 respectively. Click Good or No Good accordingly. If the latter is the case, write a comment.
* Click the [Help] button to have an advice on judging the Audio quality.
(Green): (Yellow):
All entries are made. A blank remains. Look for the blank item and input the setup data.
2) Audio Quality lamp Result of judgment on the audio quality is indicated by the Audio Quality lamp.
The audio quality is not judged yet. Open the "Audio quality check" screen and enter the result of judgment. The audio quality is judged good. The audio quality is judged no good.
* Setting of modified data of the " Microphone " section is validated after the reboot of RCU. Therefore, when a setup data is changed, do not refer to the diagnostic result made before rebooting the RCU. * The diagnostic lamp is displayed also on the SYSYTEM screen. Click the [Reboot] button on the SYSTEM screen after completing setup, and check the diagnostic lamp of the SYSTEM screen. The meaning of each lampis; 1) MIC1-9 The result of Microphone test 2) ARB The operating state of data I/F of the Audio Recording Board (ARB) and the Main Control Board (MCB)
* The diagnostic function needs to be operation. A "Diagnosis" lamp becomes a blank display when the diagnostic function is not operating. A diagnostic function can be started with the [Diagnosis] button on SYSTEM screen.
3) Serial No. Enter the serial number of the connected equipment. * If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial No. column. 4) Place Please select the equipment place of VHF from the pull-down menu.
1) Starting monitor START: Click the [Play] button. STOP: Click the [Stop] button. 2) Volume Adjust sound volume by a slide bar. Caution: When sound does not come out from the loudspeaker, check whether or not the speaker output of PC is OFF or sound volume is minimum.
4) Diagnosis Listen to the audio and judge the quality by yourself. Click the [Audio Quality check] button. Judge the audio quality on VHF transceiver 1-3. Click Good or No Good accordingly. If the latter is the case, write a comment.
* Click the [Help] button to have an advice on judging the Audio quality.
4.9.3.3.
Confirm that there is no blank in setting data. 1) Entry lamp Error in setting entry (Model, Serial number, etc.) is warned by the Entry lamp.
(Green): (Yellow):
All entries are made. A blank remains. Look for the blank item and input the setup data.
2) Audio Quality lamp Result of judgment on the audio quality is indicated by the Audio Quality lamp.
An audio quality is not judged yet. Open the "Audio quality check" screen and enter the result of judgment. The audio quality is judged good. The audio quality is judged no good.
* Setting of modified data of the "VHF" section is validated after the reboot of RCU. Therefore, when a setup data is changed, do not refer to the diagnostic result made before rebooting the RCU. * The diagnostic lamp is displayed also on the SYSYTEM screen. Click the [Reboot] button on the SYSTEM screen after completing setup, and check the diagnostic lamp of the SYSTEM screen. The meaning of each lampis; 1) ARB The operating state of data I/F of the Audio Recording Board (ARB) and the Main Control Board (MCB) * The diagnostic function needs to be operation. A "Diagnosis" lamp becomes a blank display when the diagnostic function is not operating. A diagnostic function can be started with the [Diagnosis] button on SYSTEM screen.
VDRS-VDR
4.10.2.1.1.Ships Identification Enter following ships identification data. Ships name IMO number.
4.10.2.1.2.Qty Entries made here are used by the Playback software. Enter the values.
4.10.2.1.3. VDR Identification Enter the VDR/S-VDR identification data. 1) Approval No. Enter the type approval number given by the ships class. 2) JRC shipping order Enter the shipping order number and the serial number of the RCU. 3) Serial No. Enter the serial number of the installed units that constitutes VDR/S-VDR.
4.10.2.2.1. Register information Registration information entered on the Log-in screen is displayed. Registration information which is stored in the RCU is displayed on receiving the configuration data. Registration information is updated to the data entered on the "Log in" screen after setting up.
1)
Initial The Initial means the setup in the JRC Mitaka factory. The maintainer name, company name, and the date & time (UTC) are automatically registered. Amendment The Amendment means the setup on board. The maintainer name, company name, and the date & time (UTC) are automatically registered.
2)
4.10.2.3.1. Battery The expiry date of the battery is displayed. Enter the new expiry date of the battery, when you exchange the battery. The expiry date of the battery is indicated on the battery label. If the expiry date is approaching (i.e. the battery has to be replaced within a year), the message REPLACE BATTERY BEFORE: Year/Month flickers red as an alarm
4.10.2.3.2. FAN The expiry date of the two cooling fans in the PSU of RCU is displayed. Enter the new expiry date of the cooling fans, when you exchange two cooling fans. The life of cooling fans is four years. If the expiry date is approaching (i.e. the fans has to be replaced within a year), the message REPLACE FAN BEFORE: Year/Month flickers red as an alarm
4.10.2.3.3. Beacon of capsule Enter an information data of Beacon. 1) Serial No. Enter the serial number of the capsule. 2) Next Replacement The expiry date of the battery in the beacon of capsule is displayed. Enter the new expiry date of the battery in the beacon, when you exchange the beacon unit. The expiry date of the battery is indicated on the beacon label. If the expiry date is approaching (i.e. the battery has to be replaced within a year), the message REPLACE BEACON BEFORE: Year/Month flickers red as an alarm
4.10.2.3.4.Blackout test Check whether or not the VDR/S-VDR is operable even in a blackout. 1) Starting blackout test Click the [Test Start] button. Keep the [BLACKOUT TEST] switch on the panel of PSU in the RCU passed for 5 seconds. The result will be displayed on the Test result lamp.
4.10.2.4.2.Maintenance number The Maintenance number (an intrinsic firmware number of the circuit board) of each unit (PCB) is displayed. Report all the Maintenance number for repairing.
4.10.2.5.1. PCB Serial No. The serial number of each PCB is displayed. In case of replacing a PCB, enter the serial number of the new PCB which is installed into a unit. Option unit (DSC: NCT-72/63) When the DSC is connected to the RCU, the PCB serial number of DSC can be inputted * Report the serial number of PCB which is replaced for repairing.
4.10.2.6.1. NSK (Connection) Check the check box of the NSK (CH33, 34) when a Heading data or ships speed data is recorded via NSK in VDR/S-VDR. 1) Setting VDR:
The NSK-I/F board is an option board. Click NSK box when installing the NSK-I/F board newly into the RCU. The NSK-I/F board is a standard component. The box has already been checked as default.
S-VDR:
2) System window When the NSK (CH33, 34) is checked, NSK section is displayed in the System window.
4.10.2.6.2.Outputting alarm sentence (VDR System Status) VDR/S-VDR can output error information from serial port. This function is activated when other equipment requires receiving serial data from VDR/S-VDR. 1) Setting COM: CH:
Check the check box of the COM. Select a serial port for outputting the serial data From the CH13 to CH16 are selectable ports. The CH which connected the option unit (Dry contact / Analog data) is not selectable. * Caution Set up this function after setting up the option unit connection. (Refer to 4.5.)
4.10.2.6.3. Adding of RMB Remote Maintenance System When additionally installing RMB into S-VDR, set it according to the following steps.
Note) For more detailed setting method, refer to the installation guide accompanied to the RMB kit (NZK-1850).
1 Setup operation RMB Check the checkbox of RMB [Apply] button Click [Apply] button. The configuration data required for adding RMB is sent, and then S-VDR reboots automatically. *Note If RMB add-on setting is mistakenly done, uncheck the checkbox of RMB and click [Apply] button. The configuration data without the RMB installation is sent, and S-VDR restores the condition before adding RMB.
2 Registering RMB serial number Open PCB ID tab, and then register serial number assigned to the RMB PCB.
4.10.2.7.1.Internal Dry Contact General dry contact signals can be inputted, and they can be recorded as NMEA sentence data. The number of dry contacts must be three or less. Set up the respective sentence according as the dry contact is on or off. Caution: The dry contact signals for switching Radars and switching GPSs are connected to these input ports. When the ports are occupied by the switching signals, these ports cannot be used for general dry contact signal entries.
4.10.2.7.2.Setup 1) Enable/Disable Enable / Disable of each PI port connection can be set up. Check the check box of the connected port. 2) Header of sentence data Enter the header of output sentence data. 3) OPEN sentence data The sentence data outputted when a dry contact opens is inputted. Enter the sentence data following the header. 4) CLOSE sentence data The sentence data outputted when a dry contact closes is inputted. Enter the sentence data following the header.
4.10.2.7.3.Real time monitor The real time sentence data recorded can be monitored. Make or break the contact as a try and verify that the sentence displayed repeats the try accordingly.
(Green): (Yellow):
All entries are made. A blank remains. Look for the blank item and input the setup data.
Transmit the setup data to the RCU. Transmit Click the [SET] button. Cancel Click the [Close] button.
* Setting of modified data of the "VDR" section is validated after the reboot of RCU. Therefore, when a setup data is changed, do not refer to the diagnostic result made before rebooting the RCU. * The diagnostic lamp is displayed also on the SYSYTEM screen. Click the [Reboot] button on the SYSTEM screen after completing setup, and check the diagnostic lamp of the SYSTEM screen.
* The diagnostic function needs to be operation. A "Diagnosis" lamp becomes a blank display when the diagnostic function is not operating. A diagnostic function can be started with the [Diagnosis] button on SYSTEM screen.
(Green): (Yellow):
All entries are made. A blank remains. Look for the blank item and input the setup data.
* Setting of modified data of the "Capsule" section is validated after the reboot of RCU. Therefore, when a setup data is changed, do not refer to the diagnostic result made before rebooting the RCU. * The diagnostic lamp is displayed also on the SYSYTEM screen. Click the [Reboot] button on the SYSTEM screen after completing setup, and check the diagnostic lamp of the SYSTEM screen.
* The diagnostic function needs to be operating. A "Diagnosis" lamp becomes a blank display when the diagnostic function is not operating. A diagnostic function can be started with the [Diagnosis] button on SYSTEM screen.
5. SYSTEM Screen
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
5. SYSTEM Screen
On the SYSTEM screen, the connection setup, the operating state of VDR/S-VDR system and the condition (Good/No Good) of received signal can be verified.
Enable / Disable of each connection channel and the setup of connection interface Detail setting of each connection channel Reference to and registration of information of detail setup VDR/S-VDR Warning to wrong entry of setting Display of the receiving state (OK/NG) of each serial channel Display of the state (OK/NG) of VDR/S-VDR operation: Radar, Microphone, VHF, Capsule Display of the System status information of each section: Radar, Microphone, VHF, Capsule
5. SYSTEM Screen
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
1) [Receive] button The Maintenance software receives the system configuration data of RCU Click the [Receive] button, progress of data reception is displayed on the progress bar placed at the bottom of the screen. The display of system screen will be updated by the received system configuration data.
2) [Diagnosis] button Diagnosis function is engaged by this button. Click the [Diagnosis] button then diagnosis function starts and the button burns green.
3) [Set] button This button is used to set up each system configuration data. Click the [Set] button then all the configuration data is transmitted to the RCU. * The button registers the system configuration data of each section in the detail setup window to RCU. It is unnecessary to use the [Set] button on the System screen when the detail window is opened to revise the setup data. Use the [Set] button on the System screen when all the system configuration data should be revised or only the individual check is changed.
4) [Reboot] button The button triggers to reboot the RCU. Click the [Reboot] button then the RCU will be restarted by renewed system configuration. Wait until the communication link of Maintenance software and RCU will be reestablished.
5) [All Default] button This button reconfigures the system back to the default setting as the standard connection of the VDR/S-VDR.
5. SYSTEM Screen
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
6) [Alarm Mute] button The [Alarm Mute] button is used to suspend the function of ALARM BUZZER of OPU. Click the [Alarm Mute] button then even when an error arises during the maintenance, the ALARAM BUZZER does not sound. The [Alarm Mute] button is lit green while the mute function is on. Click the green [Alarm Mute] button to cancel the Mute function. Do not forget to release the mute function before quitting the Maintenance software.
7) [ACK] button The [ACK] button on this screen works in the same way as the [ACK] button on the OPU. The [ACK] button is used to silence the ALARM BUZZER. In case multiple errors arose, presses the button as many times as the errors were raised.
Change of display
5. SYSTEM Screen
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Blinks in red
Blinks in red
Caution:
Even when the [Reboot] button blinks red, it is not necessary to click the button immediately. When all the setup is completed, reboot the RCU, and check the operation of the VDR/S-VDR.
5. SYSTEM Screen
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Diagnostic items Section Sensor VDR Radar The Software diagnosed on; Recording (receiving) the sentence or not. CF Card, expiry date of battery, replacement date of FAN, Initial error and so on. Radar image Communication link of FGB and MCB: normal / abnormal Recording radar image: receiving the RGB signal / not receiving Quality of Radar image: judgment by service engineer Microphone audio MIC test result: OK / NG Control of ARB by MCB: normal / abnormal Quality of microphone audio: judgment by service engineer VHF audio Quality of VHF audio: judgment by service engineer Capsule Communication link of Capsule and RCU: normal / abnormal BER of Capsule: within the limit / beyond the limit
Microphone
VHF Capsule
(Green): (Yellow):
All entries are made. A blank remains. Look for the blank item and input the setup data.
5. SYSTEM Screen
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
5. SYSTEM Screen
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
3) Sensor section Click [Sensor] positioned upper left of the sensor section. The recording sentence ID list appears.
5. SYSTEM Screen
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Button Log in
See 2.1.
Home
Press the button to return to the HOME screen for selecting a work item The connection, setup, and monitoring the operation of VDR/S-VDR system are available. Event log during the operation of VDR/S-VDR system appears. The list helps the maintainer to locate the fault. Press the button to playback and check the recorded data in Capsule or in CF card. A report folder is created on the Desktop after completing installation. Report files are saved into this folder automatically. Press the button then the Maintenance software disconnects the link with RCU. The Maintenance software comes to an end.
3.1
System
4.1
Event
Playback
10
Report
13
Logout
2.2
6. EVENT Monitor
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
6. EVENT Monitor
Monitors the operation event of VDR/S-VDR to check that VDR/S-VDR system is working correctly. The EVENT monitor can display the received EVENT data from the VDR/S-VDR. Additionally, the EVENT monitor can display EVENT Log files in the VDR/S-VDR.
6.1. Starting
1) Click the [EVENT] button on the SYSTEM screen.
2) Select the language to display the Event data Select English or Japanese, and click [OK].
3) Real time Event monitor Immediately after the clicking OK, the Event monitor will be turned on. Then the Event monitor displays the real time EVENT data sent from RCU.
4) RCU reboots When the RCU is restarted by the [Reboot] button on the "SYSTEM" screen with the Event monitor turned on, the Event monitor can display the event data after starting of the RCU. Reboot the RCU for checking event data from starting of the RCU.
6. EVENT Monitor
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
6. EVENT Monitor
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
1) Click the [Get Event Log (CF Card)]. 2) How long it will take to finish the receiving by Progress bar. 3) Older event data until the last real time monitor turning on is added to the event list.
1) Click the [Last boot] button. 2) The older event data before the last boot is cleared The [Last boot] button becomes blue color. 3) Click the [Last boot] colored blue. 4) Cleared old event data is displayed. (All event data display) The [Last boot] button becomes gray color again.
6. EVENT Monitor
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
2) The sorted out event data list is displayed on a newly opened Window. All category name buttons are now not selectable.
3) To change the EVENT category, close the present display Window of Extract EVENT. All category name buttons return to selectable.
6. EVENT Monitor
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
2) An event that plunges in during the sort is practiced is Not sorted, but is placed at the top of the list as the latest event.
6. EVENT Monitor
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
1) Opening a file Point to Open on the File menu. Then the File dialog appears.
2) Selecting a file Select writefile.txt on the folder where Event log is saved. 3) Displaying the event log Event log data is displayed on the event list.
1) Saving a file Select Save or CSV Save on the File menu. Save: Saves evt file CSV Save: Saves csv file
6. EVENT Monitor
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
3Record stop Click the [Record Stop] button. Then [Record Stop] changes to [Record Start].
6. EVENT Monitor
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Radar image
Starting
Each real time monitor can be started from the menu directly. Use these real time monitors for checking the received data only apart from setups.
7.1. Starting
1) Menu Click the Monitor menu. 2) Pull down menu Point to the item to be monitored and click it (NMEA, Audio, Radar, Dry contact).
If the specification of the laptop PC is relatively low, single channel monitoring is recommended. Incase two or more channel are monitored at a time, CPU load rises to 100%, and operation may stop. When the software freezes, press <Alt>+<Ctrl>+ <Delete> then Windows Task Manager will appear. Terminate the maintenance software there.
7.2.1.1.
Select the CH to monitor. Click the CH to monitor from the pull down menu.
7.2.1.2.
Monitors all the receiving data from the selected channel. The sentence data which is not recorded by the VDR/S-VDR is also displayed. Monitors the sentence data which is recorded by the VDR/S-VDR only. The sentence which is not recorded is not displayed even when it is received. Monitors the data currently set in the VDR/S-VDR.
RCV data monitor Verify the receiving data by this in the event of receiving NG. When the wiring is reverse, unfamiliar characters will appear.
REC data
The addition and deletion of the CH to the monitor can be operated freely.
RCV data
Capable of single channel monitoring only. In case multi channels are monitored on RCV data, a mixture of received data is indicated.
2)
7.2.6. Quit
1) Abide by the following procedure to quit monitoring. Otherwise an error arises. Stop all of the monitoring channels. Then click [Close] to quit.
2)
Before quitting the maintenance software, please make sure that the real time monitor has been stopped. Reboot RCU, if the maintenance software has been quitted without stopping the real time monitor to stop outputting the real time data.
Select the CH to monitor. Multiple channels cannot be played at a time. For each connected unit (MIC1,2,3,4,5,6,7,8,9, VHF1,2,3), connect only one unit to check the operation. Each monitor CH receives a mixture of 3 input signals. To verify that each unit is correctly working, it is necessary to connect only one unit to the monitor.
The monitored sound is played about four second later than the sound source.
7.3.4. Quit
Click the [] button on the upper right of the window after monitor stop.
7.4.1. Operation
No need to operate since the monitor functions of itself. The image that the VDR/S-VDR is recording is displayed. The image is updated every 15 seconds as well as the image record. The monitored image is displayed a few seconds later than the record time.
Sentence sent from the NCT-72/63 When the state of a dry contact changes. Every 5 minutes and at the time power supply is turned on (all sentences).
The present position is displayed by a green lamp on "Engine telegraph position", "Sub-telegraph position", and "Operating location" . When the [Back] button is clicked, an engine telegraph window will be closed and returns to the dry contact state window.
8.1. Starting
Click the System Status from the System pull down menu.
8.5.2. File
Open the system configuration file (VdrDataInfo.dat). On the File menu point to Open and click.
9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
9. Functions of Menu
This chapter explains the auxiliary functions that can be executed from Menu.
Menu File
Function File open : System configuration file of the VDR/S-VDR or the RMS System status file of the VDR/S-VDR or RMS Moreover, by opening the system configuration file (SysInfo.dat, VdrDataInfo.dat) saved at the report folder created after the completion of installation, the system status file (Status.dat) saved at the same folder can be opened automatically, and then the diagnostic result at the completion of installation can be reappeared. Refer to chapter 13 about the report folder.
Refer to; -
Save Control System MCB Setup RMB Setup System Status FGB setup FGB Utility FGB Update HVR Event Monitor Event Monitor NMEA Audio Radar Dry Contact Convert
File save : System configuration file of VDR/S-VDR or the RMS Controls the VDR/S-VDR by the Maintenance software Edits system configuration data of the MCB Do not use this function without an instruction by JRC. Edits system configuration data of the RMB Do not use this function without an instruction by JRC. Shows the system status Shows the WEB of the FGB Do not use this function without an instruction by JRC. Adjusts the FGB Updates the program of FGB Shows the web of the capsule Do not use this function without an instruction by JRC. Real time monitor of EVENT Real time monitor of NMEA sentence Real time monitor of audio Real time monitor of image Real time monitor of dry contact Converts the recorded data to general file which is opened by standard application software on PC. NMEA data: Converts to text file Radar image data: Converts to PNG file Audio data: Converts to WAV file Extracts a setup file from Config file saved in the CF card and the capsule Download the latest sensor data file and Radar image file recorded in CF card. Shows meanings of Error code displayed on the OPU
Data
Config Card Download Help Error Code List (English) Error Code List (Japanese) Software Version
9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
9.2. Control
The VDR/S-VDR can be controlled by the Maintenance software.
9.2.1. Starting
Click the Control on menu.
9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
9.2.5.1.
1) Click the subject unit button. ([MCB] button or [RMB] button) The date and time of a unit selected is displayed.
9.2.5.2.
1) Click the subject unit button. ([MCB] button, [RMB] button) The date and time of unit selected is displayed. 2) Enter the date and time. 3) Click the [Set] button. 4) Click the [Reboot] button of the target unit. (Refer to 9.2.1)
5) When the unit is rebooted, the entered date and time is set firm. Confirm the date and time after rebooting.
9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Regularly, MODEApplication FUNCTIONNormal should be displayed. When the update of the program ended in failure and the software freezes with the function status remaining "Download", Request Unit Mode shifts the status back to Normal. Click the [Cancel] button.
If the [Cancel] button has no effect on shifting the function status back to Normal mode, there is something wrong with the equipment. Make call to service department and go into details.
9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
9.3. Converting the Recorded data to general files (.txt .png .wav)
The recorded data saved in the CF card or downloaded from the capsule can be converted to general files which are opened by standard application software on PC. Config data: Converts to text file (CSV) NMEA data: Converts to text file Radar image data: Converts to PNG file Audio data: Converts to WAV file
[Convert] button
9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
In order to convert recorded data of the CF card, select folders or files which were enclosed by the dashed line. CF card drive Init Log Audio Visual
2)
Converting Click the [Convert] button. Then conversion of files starts. When conversion starts, conversion status is indicated by progress bar. And converted files are indicated in the list box. [Convert] button
9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
3)
By drag and drop, recorded data can be converted as follows also. In case of drag and drop, not only a converted folder, but also a file can be selected.
9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Mix MIC-CH1, CH2 and CH3 Mix MIC-CH4, CH5 and CH6 Mix MIC-CH7, CH8 and CH9 Mix VHF-CH1, Ch2 andCH3 Main Radar Image Sub Radar Image
YYMMDD: Date hhmmss: Time (UTC) ????????: IMO No. (If IMO number is not entered, automatically converts to 99999999.)
9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
9.4.1. Starting
1) Click the "Config" from the "Data" pull down menu on the system screen.
9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
1Click Card Download by opening the pull-down menu of Data on System screen.
2Select the file desired to be downloaded, and then click [Download] button.
Since the Radar image file is converted to PNG format after being downloaded, the file can be checked by opening it immediately after that.
9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
9.6.1. Starting
1) Click the "Error Code List" from the "Help" pull down menu on the system screen.
The content, the cause, and the correspondence method of the error code are displayed at the right of the screen.
9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
9.7.1. Starting
1) Click the Software Version from Help menu.
10. Playback
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
10. Playback
Verify that the installation and the setup have been finished successfully and the VDR/S-VDR works satisfactory by playing back the data of the capsule and the CF card.
10.1. Starting
10.1.1. Start on the SYSTEM screen
Click the [Playback] button on the SYSTEM screen.
10. Playback
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Check the recorded data of both the capsule and the CF card at the end of installation. Playback procedure of capsule data is different from that of CF card. Playback and check the recorded data referring to the procedure mentioned in 15. Playback Software setup.
11. Frame Grabber Board (CKA-137) Setup - FGB Utility JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
11. Frame Grabber Board (CKA-137) Setup - FGB Utility FGB_Utility software is useful for setting up and tuning the Frame Grabber Board CKA-129/CKA-137. The setup menu has Board setup function with the aid of capture setup file and other file. The tuning menu allows maintainer to tune sync polarity, horizontal/vertical synchronization and sampling phase.
11. Frame Grabber Board (CKA-137) Setup - FGB Utility JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
capture setting] menu, referring to the next section. Immediately after the click, the following message appears. This message appears only on the first connection to the board.
c) "Changed to channel 1" message appears at the left bottom corner of the window.
11. Frame Grabber Board (CKA-137) Setup - FGB Utility JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Measured value
Sync Activity ch 1 Sync Activity ch 2 V sync polarity H sync polarity V sync frequency H sync frequency: Total line number Setup value V sync polarity H sync polarity
c) Check that the Radar image format measured by CKA-137 is the same as that of the Rader specifications.
Resolution (estimated value): Vertical synchronous signal frequency (Refresh rate): Horizontal synchronous signal frequency: Vertical synchronous signal polarity: Horizontal synchronous signal polarity:
If the Sync Activity column is inactive, most probably synchronous signal could not be detected by the board. Verify the wiring, signal output and input channel.
11. Frame Grabber Board (CKA-137) Setup - FGB Utility JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
b) Click the "CKA137-JCY1800" folder. (If CKA-137 board is installed in JCY-1700, click the "CKA137-JCY1700" folder.)
c) Click the capture setting file. File name is formatted as shown bellow. JRC Radar setting: Cap2-"Radar model name"-1800.txt | | | CKA-137 board installed in JCY-1800/1850 ex. JMA9900 VESA format setting: Cap2-"Resolution"-"V sync frequency"-1800.txt Resolution: 800x600, 1024x768, 1152x864, 1280x960, 1280x1024, 1600x1200 pixels V sync frequency: 60, 70, 72, 75, 85 Hz (a display of 1600x1200 resolution meets 60 Hz only.)
11. Frame Grabber Board (CKA-137) Setup - FGB Utility JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
d) Click the [Open] button on the file select window. The following message appears. If "Capture1.txt write NG" message appears, retry step a) to d).
b) Click the
icon.
11. Frame Grabber Board (CKA-137) Setup - FGB Utility JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
11.3. Tuning
Tune the image in the following order. 1) Sync polarity tuning 2) Horizontal position tuning 3) Vertical position tuning 4) Sampling Phase tuning
Measured value
Setup value
11. Frame Grabber Board (CKA-137) Setup - FGB Utility JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
d) Click the [Tuning (T)] -> [H Sync polarity reverse] The following message appears.
e) Click the [OK] button. The click reverses the H sync polarity and captures the image. Then the following message appears.
g) Have a look on the [ADC status] menu, and check that the measured H sync polarity is the same as that of the setup. Regarding the V sync polarity, follow the same procedure using [V Sync polarity reverse] menu.
11. Frame Grabber Board (CKA-137) Setup - FGB Utility JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
11.3.2.1. Coarse tuning by the mouse a) Click the [Tuning (T)] -> [Horizontal POSI. Mouse] menu. The following message appears.
b) Click the [OK] button. Then automatic image capture starts, and the following message appears.
c) Click the [OK] button on the message box. The message box disappears.
d) Click the horizontal edge of the image. Dont care the Y coordinates.
11. Frame Grabber Board (CKA-137) Setup - FGB Utility JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
e) To practice horizontal position tuning at this point, click [Yes]. the horizontal edge of the image.
After successful horizontal position shift and image capture, the result message appears.
11.3.2.2. Manual (fine) tuning a) Click the [Tuning (T)] -> [Horizontal POSI. manual] menu. The following message appears.
b) Click the [OK] button on the message box. After automatic image capture, the following message appears.
c) To have the image moved left, click the [Yes] button. To have the image moved right, click [No]. tuning, click the [Cancel] button. After successful horizontal position shift and image capture, the result message appears.
To finish the
11. Frame Grabber Board (CKA-137) Setup - FGB Utility JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
11.3.3.1. Sampling Phase tuning If the captured image is out of focus, tune the sampling phase to achieve the best sharpness. Normally, go to Phase AUTO tuning. A phase AUTO tuning is practiced on still image, stop the transmission of Radar.
a) Click the [Tuning (T)] -> [Phase AUTO] menu. The following message appears.
b) Click the [OK] button on the message box. Phase AUTO tuning start, and 35 images will be captured for tuning. During the tuning, the process is displayed on the left bottom corner. AT the end of the tuning, a result message appears.
12.1. Starting
12.1.1. Starting from SYSTEM Screen
In order to display OPTION system setup screen from SYSTEM screen, click [HOME] button to go to HOME screen at first.
The setup operation of multicast is the same as that of the conventional real-time monitor except entering the IP address for simultaneous distribution.
12.4. IP Address
12.4.1. For Real Time Monitor
The VDR/S-VDR outputs the real time data to the specified IP address. To change the IP address, open a Network window by clicking the [Edit] button. 1) VDR-WAN port Designate the IP address of VDR-WAN port on RCU which is connected to the option PC. Default: 192.168.0.254 2) Option PC Designate the IP address of the monitor PC. Default: 192.168.0.251
3) When distributing real-time data via router: In order to distribute real-time data via router to the computer in the different network from the network to which VDR is connected, check the checkbox of "Router" on the Option PC main screen. Click the [Edit] button to display the setup screen. Enter router IP address in the Next Hop field, and then click the [Set] button. Default: 192.168.0.253
2Address Enter a multicast address. Default: 239.0.112.1 3Port Enter a port number. Default: 6501
Reception side should also set up the same multicast address and port number as what was set up above.
Multicast output can distribute sensor data only. Check the checkbox of the CH to be output.
13. Report
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
13. Report
When the installation is completed, create a set of report files using this function.
13.1. Starting
1) Click the [Report] button on the SYSTEM screen. Report screen will appear.
13. Report
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
13.1.1. Report
Setup data, diagnosis, check result and so on can be confirmed in the Report screen. And all the contents are saved to files as service report. Since the Report files are registered in the Ship List of the Marine Service Department Home Page, send the files to the Marine Service E-mail address with the following subject. Subject : JCY-1800 Report (or JCY-1850 Report) E-mail :tmsc@jrc.co.jp 13.1.2 Report screen
13. Report
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Composition of Report screen Contents Ships Information VDR register information Checking of Installation Checking of setup and operation Checking of setup and operation Checking of setup and operation Checking of setup and operation Checking of setup and operation Checking of setup and operation Checking of setup and operation Checking of capsule operation Checking of blackout test Checking of Playback software Checking of Event Monitor Amendment resister information Amendment register information Check Diagnosis Entry Contents Comment Unit Info
Ships Information VDR Information Installation Sensor NSK (CH33,34) A/D VDR Radar Microphone VHF Capsule Blackout Playback Event Option PC RMS 1) 2) 3) 4) 5) 6)
: Quality judgment of operation by serviceman : Lamp indication by Diagnosis : Lamp indication by Entry check : Registered contents in VDR with Maintenance software : Comment to judgment of Diagnosis or Entry check : Detail of connected unit
: Automatic input item (Registered contents with Maintenance software) : Input items in the Report screen : Comment input item
13. Report
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
13.1.4
Search Function There are 4 buttons for searching item of NG judgment or no entry in the Report screen. A deficient report which is not can be created by using these functions. Search target Entry Search condition When Entry lamp is: NG lamp No-entry lamp When Diagnosis lamp is: NG lamp NoteIt is excepted during diagnosis. Incase of no entry In case of no-selection Incase of NG NoteNo-comment is excepted. Measure Return the setup screen by the [System] button. And input item which is not inputted. Return the setup screen by the [System] button. And check the cause and cancel error. Input so that there is no blank. In case of no-selection, select OK or NG. In case of NG, input error cause in comment box.
No. 1
NG lamp of Diagnosis
Diagnosis
3 4
Contents Check
Operation 1) Select any one from 4 Search selections in the Tab Selection. 2) Tab select button which is searched blinks red. 3) Click the tab select button which blinks red. Tab screen can be selected by click tab directly also. 4) Searched item is indicated by red. In order to cancel error, measure in accordance with above table.
13. Report
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
13.1.5
Save report file When the [Save] button is clicked, report folder is created instantly as RCU serial number (MBxxxxxx)_VDR_report on the desktop screen. Moreover setup files the other than a report files are saved as service report instantly into the report folder. Compress the report folder, and send it to the Marine Service E-mail address with the following subject. The Report files are registered in the Ship List of the Marine Service Department Home Page Subject E-mail : JCY-1800 Report (or JCY-1850 Report) :tmsc@jrc.co.jp
Saved files: Report file MCB system configuration file RMB system configuration file *1 MCB system status file RMB system status file *1 FGB setup file *1 DSC setup file *1 Event log file Radar image file *1 Sensor data file *1: In case of non-connection, the files are not saved.
Save the report file by [Save] button. If necessary, the report file can be renamed and saved.
If the report is saved, save folder, file name and creation date is indicated.
Creation date
13. Report
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
13.1.6
Open report file Click the [Open] button, and select report folder in the Open screen, select a report file. Contents of selected report file are indicated. If necessary, the opened report file can be and corrected. Because diagnosis is started automatically in the report screen, latest Diagnosis results are updated into the opened report file.
Save folder, file name and creation date of opened file are indicated.
Creation date
14.
Program Update
Update the program of MCB, ARB RMB and FGB in the RCU according to the following instructions.
The RCU is restarted automatically and operated with the renewed program after the updating has been completed. It is not necessary to reconfigure the system following the update.
2) Check the version of the updated program. Click the [Version] button and the version will appear. 3) Quit the update application.
1) FGB WEB screen Click the [FGB Setup] from the System menu on the System screen.
Internet Explorer (IE) starts and the root menu of the FGB WEB screen is displayed.
2) Put the FGB in SLEEP mode as a preparation for program update. Click the [Sleep] button on the root menu. Confirm that OK message appears.
of IE, and the display screen will go back to the root menu.
Software Version
2)
Update software version saved in the maintenance software is displayed on the Capsule Update"dialog. If the version is out of date, select the latest version by clicking the [Browse] button. After the select update software version is displayed, click the [Yes] button to proceed.
Note)
The Open dialog displays by clicking the [Browse] button. Select the folder where the latest update software is saved, and then update the capsule. Capsule update software file name xVR02 type: ram_XVR02_x-xx-xxx.bin xVR03 type: ram_XVR03_x-xx-xxx.bin
3)
4)
Confirm current software version by clicking the [Get Current SW Version] button. Software version
5)
Input a mark beside Automatic Reboot after update, and then start update process by clicking [Update Software] button.
6)
Updating status is indicated in the Status bar. When the update is completed, confirm the software version by clicking the [Get Current SW Version] button.
Updating status 7) Click the [Exit] button to close the update screen.
15.
15.1. How to play back the downloaded data from the Capsule via Ethernet
The flow from Setup to Playback is shown below. Stop recording to capsule.
15.1.1.
[DOWNLOAD] button
Note) Download data size can be specified in every 1 % with slide bar. Check the box of necessary download data and click the [Start] button. Please press [OK] button, click [Cancel] button of the download software, and end the download software.
When the following screen appears, download is completed. Click the [OK] button, and close the Download software with the [Cancel] button.
Download
OK
NoteFolder Composition Save Place (Save Folder) Save FolderCreated by the folder name registered on the input screen ((5) section). Playlist1 Playlist2 VDR Init Log Audio Visual Event
Playlist3
Playlist10
15.1.2.
[PLAYBACK] button
Click the [SETUP] button on the PLAYBACK launcher menu, and start the Setup software.
[SETUP] button
The Login screen appears. Click the [OK] button after confirming that User has been clicked in the Operator block.
User
To import VDR/S-VDR configuration data, select the following file in the download data and click the [Import] button. : Playlist2VDRInitSysInfo.dat Download folder
Click the [Folder Selection] button, and select the folder created in accordance with the 3.1.3 Download data from VDR/S-VDR by Download software.
Click the [Set] button, and the setup is completed. To close the Setup software, click the [Close] button.
15.1.3.
1)
[PLAYBACK] button
2)
Click the [PPLAYBACK] button on the PLAYBACK launcher menu, and start the Playback software.
[PLAYBACK] button
3)
4)
Slide bar
Playback button
Playback time span of the Slide bar can be selected by the Slide bar select button. 12hours: 12 hours All: All the periods of record data
Note In case of downloading from the Capsule, the record data period might be for a few days. Playback time span of the Slide bar becomes long, and so it is not easy to adjust playback time. In that case, select the 12 hours in the Slide bar select button. Playback time span becomes 12 hours; moreover, scale in every hour is displayed. So it is easy to adjust playback time.
5)
Start the Playback software, and copy the record data of CF card.
15.2.1.
1) 2)
15.2.2.
1)
[PLAYBACK] button
2)
Click the [SETIP] button on the PLAYBACK launcher menu, and start the Setup software.
[SETUP] button
3)
As the Login screen appears, click the [OK] button after confirming that User has been clicked in the Operator block.
User
4)
Eject a CF card from the VDR/S-VDR, and insert to the card slot of another laptop PC. Then, to import VDR/S-VDR configuration data, select the following file in the CF card and click the [Import] button. Note: Which drive is for CF card depends on the PC model. D: InitSysInfo.dat CF card drive as an example
5)
Click the [Folder Selection] button, and select a folder created in accordance with the 3.1 Create a playback folder.
6)
Click the [Set] button to finish the setup. To close the Setup software, click the [Close] button.
15.2.3.
1)
[PLAYBACK] button
2)
Click the [PLAYBACK] button on the PLAYBACK launcher menu., start the Playback software
[PLAYBACK] button
3)
4)
Playback button 5)
Playlist button
Verify whether or not the CF card drive is set in the Copy source. If not, click the [Folder Select] button to select the drive. Select a playlist in the Copy place and copying data volume in the Size and then click the [Copy] button. Copying volume can be selected from 1hour to 12 hours or all. If 1hour is selected, 1 hour data from the latest is copied.
6)
7) 8)
Check playlist2-Playlist10 where CF card data have been copied, then click the [OK] button. Click the [Playback] button on the playback panel to start playback.
[Setup] button
2)
Click the [Exit] button located bottom left in the Setup screen.
[Exit] button
16.
16.1. Log in
16.1.1. Log in to the RMS after setting up the VDR or S-VDR
Login again to Remote Maintenance System (RMS). . 1) Return to the Log in screen. Click the [Loginon the left side of screen.
Select the RMS, and then click the [Next] button. The HOME screen of RMS appears.
Select the RMS, and then click the [Next] button. The HOME screen of RMS appears. 2) Select the subject equipment (VDR or S-VDR).
* When the S-VDR is connected to the Inmarsat (Fleet), S-VDR will be maintained with the RMS.
1) Receiving configuration data Click the [Receive] button to receive configuration data. The connection setup screen of VDR/S-VDR displays. 2) Connection setup of the JRC equipment connected to VDR (For VDR/S-VDR with built-in RMB only) Check the checkbox of RMS connection channels. Usually, setup is completed only by checking.
3) Connection setup of the JRC equipment newly connected for RMS (For VDR/S-VDR with built-in RMB only) Check the checkbox of channels to additionally register the connection setup of the JRC equipment connected for RMS. Click the [Detail] button, and then the detail setup window appears. Enter the identification data and interface data of connecting equipment like setup for VDR. The sentence ID of maintenance sentence (PJRC) is inputted automatically. 4) Setting up the IP address (to VDR and S-VDR) Set up the IP address of VDR and Inmarsat (Fleet).
Equipment which is set up for VDR connecting Setup is completed already, so setup data cannot be modified. Equipment which is set up for RMS connecting newly Set up identification data of equipment. Comment Enter helpful information for maintaining. The entry of a comment is not mandatory. Enter the identification data and interface data of connecting equipment like setup for VDR. The sentence ID of maintenance sentence (PJRC) is inputted automatically.
Equipment which is set up for VDR connecting Setup is completed already, so setup data cannot be modified. Equipment which is set up for RMS connecting newly Default data is inputted automatically. Modify the default data which is not adapted to connected equipment. Sentence ID for maintenance PJRC is inputted automatically for Remote Maintenance. Some equipment may require another sentence ID. If sentence ID have to be changed, setup information will be released by the Marine service WEB. Max interval (RMS) Set the maximum time interval of receiving. If the time taken to receive a data sentence exceeds this limit, the sentence is denied and an error arises. Set a longer time when an error arises.
IP address Set up the IP address of equipment which output a maintenance sentence. (IP address: 192.168.60.xxx)
IP address table
Sentence ID for maintenance PJRC is inputted automatically for Remote Maintenance. This ID cannot be modified. Max interval (RMS) Set the maximum time interval of receiving. If the time taken to receive a data sentence exceeds this limit, the sentence is denied and an error arises. Set a longer time when an error arises.
2) Link test
Click the [Start] button, and then the lamp lights in green or red as a result of test. (Green): Result of test is good. (Red): Result of test is not good.
3) Modifying the IP address Modify the IP address of VDR and Inmarsat (Fleet) when the IP address set up cannot be adapted to the Network. Test the link of LAN after modifying the IP address.
1) Click the [Diagnosis] button. 2) Confirm that the color of [Diagnosis] button changed to green. If the [Diagnosis] button is clicked during the diagnosis function is on, the function will be stopped.
5[Download] button 6Viewer screen start button Latest data Log data Received data
1Connected equipment information When RMS main screen is in communication (when it is opened), it acquires system configuration information from RMS and displays it. It displays the equipment connected for RMS, not for the exclusive use of VDR. 2Reception lamp When PJRC sentence (maintenance data) is being received in specified interval time, the Reception lamp indicates green. If not, it indicates red. 3Alarm lamp When the relevant equipment is operating normally, the Alarm lamp indicates green. If it is generating the error, the lamp indicates red. Acquire (Download) maintenance data of the equipment with error indication, and then analyze the root cause. * Speed LogJLN-205550: The Alarm lamp always shows in orange since it utilizes special sentence.
4Selecting download data Checkboxes for the following data in each CH are provided. Check the only checkbox of necessary maintenance data, and then download it. Latest dataTarget sentence: PJRCLPJRCMPJRCD The latest data of each maintenance sentence are recorded. Log data Target sentence: PJRCL The log data is recorded only if the change occurs in the content of receiving sentence data. Download it by specifying the download size (0-100%) in relation to all storage capacity of recorded data. Received dataTarget sentence: PJRCLPJRCMPJRCD All received maintenance sentence data are recorded. Download it by specifying the download size (0-100%) in relation to all storage capacity of recorded data. 5[Download] button The download of specified maintenance data starts by clicking the [Download] button. Downloaded data can be saved as a file and displayed. 6Viewer screen start button The viewer screen of downloaded data can start up by clicking viewer screen start button after the data downloading.
16.3.6.3. Selecting download data 1Individual selection Click to check each checkbox of maintenance data that you desire to download. When downloading multiple data at the same time, check all checkboxes of the data concerned. 2Package selection When downloading all maintenance data, all checkboxes can be checked together at the same time. Select All Check from View menu. As the following checkboxes display in the right side of screen, check the checkbox of necessary data classification.
3Download Click the [Download] button to start downloading the maintenance data.
16.3.6.4. Viewing downloaded data 1Selecting target equipment Click the [CH**] button of target equipment to display the maintenance data viewer window.
Click the [Data Form] button to display the file selection dialog. As conversion file list displays, select a conversion file for the equipment concerned from the list.
Select the maintenance data classification from menu bar. Latest Latest data LogDiff Log data LogAll Received data
16.3.6.5. Latest (Latest data) The latest data of each sentence (identified by the sentence number) can be displayed. Each sentence is converted to text first, and then displayed. Data status (OK: Green lamp, NG: Red lamp Received date & time (UTC) & ships position at the time of reception (Lat / Lon)
16.3.6.6. Log (Dif) (Log data) The recorded maintenance data displays only if the change occurs in the content of receiving maintenance data sentence. Selected sentence is converted to text first, and then displayed.
New
Old
16.3.6.7. Log (All) (Received data All received and recorded maintenance data are displayed. Selected sentence is converted to text first, and then displayed.
17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
17. Installation
Here the installation procedure of the maintenance software for JCY-1800 / 1850 is described.
for Windows Vista When you install the maintenance software, you should log into your PC by administrator account and execute it. In that case, execute by the "Allow" of the confirmation screen. When the Setup.exe is clicked , the confirmation screen is displayed. Select the "Allow" and start installation.
Allow
17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
1) Perform setup.exe Double-click thesetup.exe file. 2) Start installer When the [Next >] button appears, click it after displaying the following window.
3) Input the user information Input jrcvdr into the serial number block and click the [Next >] button.
17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
4) Installation folder As default, Program FilesJRCJCY1800Maintenance is specified as the installation folder. Click the [Next >] button.
6) Click the [Finish] button. The installation of the maintenance software is completed.
17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
7) The installer of Tera Term starts continuously. Tera Term Hyper Terminal has been discontinued in Windows Vista. When the VDR IF (router) of VDR real time monitor is set up, Use the Tera Term instead of Hyper Terminal.
9) Select "I accept the agreement", and click the [Next>] button.
17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
16) Installation of the Tera Term is completed The icons of the JCY-1800 Maintenance software and the Tera Term software are created on the desktop.
17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
17When Windows Vista PC is used, it is necessary to continue and to cancel UAC (user account control). Cancel it according to the following operations. Right-click in the JCY-1800 Maintenance" icon on the desktop.
Select Properties.
Compatibility tab
17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Input a "" mark in "Run this program as an administrator" of "Privileged level", and click the [OK] button.
Privileged level
For Windows Vista When you use the maintenance software, you should log into your PC by administrator account and execute it. In that case, execute by the "Allow" of the confirmation screen.
Allow
17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
3Select the "Regional Options" tab, select the "English (United States)" or the "English (United Kingdom)".
4) Select the "Advanced" tab. Select the "English (United States)" or the "English (United Kingdom)", and then click the [OK] button. You will be asked to restart Windows, and then restart it.
Advance tab
17. Installation
JCY-1800/1850 For Windows Vista 1 Click the Clock, Language, and Region on Control Panel screen. VDR/S-VDR Maintenance Software Instruction Manual
17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
3 Select the "Formats" tab, select the "English(United States)" or the "English(United Kingdom)",
Format tab
4 Select "Administrator" tab. Click the [Change system locale] button, and select the "English (United States)" or the "English (United Kingdom), and then click the [OK] button. You will be asked to restart Windows, and then restart it.
Administrator tab