Sie sind auf Seite 1von 5

TITULO:

DOCUMENTO N:

INSTALACION DE MEDIDORES DEL GAS COMBUSTIBLE CONSUMIDO POR LOS TURBOCOMPRESORES


HOJA DE DATOS DE MUESTREADOR AUTOMTICO

PCAM-200-HD-K-002
REVISION A

*PCAM-200-HD-K-002*

A REV.

EMITIDO PARA REVISION INTERNA DESCRIPCION

3/7/2012 FECHA

LTM POR

ACO REV.

WFC APR.

SERVICIOS DE INGENIERA PARA LA PLANTA DE GAS DE MALVINAS Y PLANTA DE FRACCIONAMIENTO DE PISCO


SM-008-2011 / MALVINAS
TITULO:

INSTALACION DE MEDIDORES DEL GAS COMBUSTIBLE CONSUMIDO POR LOS TURBOCOMPRESORES


HOJA DE DATOS DE MUESTREADOR AUTOMTICO
INGENIERIA DE PROYECTO
ESCALA: DOCUMENTO N:

SM-008-2011 INSTRUMENTACIN
REVISION:

S/E

PCAM-200-HD-K-002
160857-253-8-HD-002

A
Hoja 1 de 4

CLIENT: JOB:

PLUSPETROL PERU CORPORATION S.A. INSTALACION DE MEDIDORES DEL GAS COMBUSTIBLE CONSUMIDO POR LOS TURBOCOMPRESORES INSTRUMENT DATA SHEET CONTENTS INSTRUMENTATION

PAGE: 2 of 4 DATE: 3/7/2012

REVISION A

1. 1.1

SCOPE Automatic Sampler - Fuel Gas To Turbocompressors including: There are two Fuel Gas System (Nuovo Pignone and Siemens). Once system will have a Automatic Sampler with: One Sampler, Solenoid, Regulator Pressure, Controller, Receiver and minor stuff.

1.2

The whole supply shall be according to DOCS. N PPAG-100-ET-K-009 PPAG-100-ET-K-010 PPAG-100-ET-C-004 PPAG-100-ET-C-029 PCAM-415-PL-Y-403-2 PPAG-415-PL-Y-667 PPAG-100-ET-X-002 PPAG-100-ET-C-002 Instrument Design Instrument installation Piping Class Index Piping Class "B1" - ASME 300 #

(----- Revision)

FUEL GAS TO TURBO COMPRESSORS 1 TO 5 PROCESS FLOW DIAGRAM OF FUEL GAS DISTRIBUTION SYSTEM Selection and Application of Protective Coatings Cleaning, pressure testing, preparation of pipe system for start-up

1.3 *

List of Components AE - 8022 / 28023 AUTOMATIC SAMPLER Qty.: 2

1.4

System Description The New Gas Metering Architecture, shall be according to PPAG-300-PL-K-101 *

* The Automatic Sampler shall communicate with: - Flow Transmitter - Delta V System

RS-485, Modbus RTU Protocol RS-485, Modbus RTU Protocol

CLIENT: JOB:

PLUSPETROL PERU CORPORATION S.A. INSTALACION DE MEDIDORES DEL GAS COMBUSTIBLE CONSUMIDO POR LOS TURBOCOMPRESORES INSTRUMENT DATA SHEET SAMPLER INSTRUMENTATION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 TAG NUMBER DESCRIPTION SERVICE P&ID No LINE N SIZE / SCHED. CUSTODY TRANSFER APPLICATION DESIGN CODE FLUID SPECIFIC GRAVITY MASS DENSITY VISCOSITY VAPOR PRESS. @ 60F SEDIMENT % MAX. PART SIZE H2S % TOTAL SULF. WT. % NEUT. N. ADITTIONAL INFO. MIN. FLOW RATE OP. FLOW RATE MAX. FLOW RATE OP. PRESSURE OP. TEMPERATURE AMB. CORR. PROP. MIN. MAX. AMB. TEMP. RELATIVE HUMIDITY (MEAN) COLLECTION PERIOD DRIVE SYSTEM DESIGN PRESSURE DESIGN TEMPERATURE SAMPLE PROPORTIONAL TO FLOW OR TIME: METER MANF. TYPEACCURACY METER SIGNAL TYPE CONTROLLER SIGNAL CONTROL FEATURES DESIRED TOTAL VOL. DESIGN PRESSURE DESIGN TEMPERATURE VESSEL MAT'L COATING (INT) COATING (EXT) INSTALLATION ACCESORIES REQ'D HANDLES VAC BKR LEVEL GAGE Q.O. CONN RELIEF VALVE Q.R. COVER PRESS GAGE ALARMS LOSS OF SIG HIGH LEVEL LOSF LOFLF EXTR FAIL LOMP

PAGE: 3 of 4 DATE: 3/7/2012

REVISION A

GENERAL

PROCESS DATA

AE - 8022 / 28023 AUTOMATIC SAMPLER TURBO COMPRESSORS'S FUEL GAS METERING SYSTEM PCAM-415-PL-Y-403-2 / PCSE-415-PL-Y-441 8"-FG-415015-B1-H / 8"-FG-416507-B1-H1" 8" - SCH 40 YES API MPMS CH. 14, SECTION 1 NATURAL GAS 0.621 1.417 lb/ft3 0.0122 cP N/A N/A N/A N/A

PROPIEDADES Y CONTAMINANTES

DESIGN DATA

30 MMSCFD 45 MMSCFD 60 MMSCFD 430 PSIG 95 F 52 F 80 % HOURS 100 F DAYS BBL

SAMPLER DATA

SAMPLE RECEIVER

NOTES:

REVISION A

NATURAL GAS 1.417 lb/ft3 0.0122 cP

100 F

CLIENT: JOB:

PLUSPETROL PERU CORPORATION S.A. INSTALACION DE MEDIDORES DEL GAS COMBUSTIBLE CONSUMIDO POR LOS TURBOCOMPRESORES INSTRUMENT DATA SHEET FLOW COMPUTER INSTRUMENTATION 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 57 58 59 60 61 62 PERMANTENT OR PORTABLE PACKAGE SERVICE ELECTRICAL VOLT: Hz: AIR INSTR: PRESS: PLANT: PRESS: SAMPLER GENR'L PURP. CLASIFICATION SWITCHES (TYPE) CONTR. UNITSAMPLER GENR'L PURP. CLASIFICATION SWITCHES (TYPE) ALARMS GENR'L PURP. CLASIFICATION SWITCHES (TYPE) ELECTRICAL CERTIFICATIONS: PRESSURE CERTIFICATIONS: PORTABLE YES

PAGE: 4 of 4 DATE: 3/7/2012

REVISION A

INSTALLATION

AVAILABLE UTILITIES

PHASE:

CLASS I, Div. 2, Gr. C & D

ELECTRICAL DATA

CLASS I, Div. 2, Gr. C & D

CLASS I, Div. 2, Gr. C & D

OTHERS

OPTIONS

PURCHASE
NOTES:

MANUFACTURER MODEL NUMBER


INSTALL.

CAMERON OR EMERSON OR SIEMENS BY VENDOR

1.- VENDOR SHALL SUPPLY THE FLOW COMPUTER INSTALLED IN A WALL-MOUNTING PANEL FULLY ASSEMBLED, FULLY FUNCTIONAL AND READY TO

2.- SHALL BE EXPANDABLE TO MANAGE UP TO 8 METER TUBES VIA EXPANSION CARDS.