Beruflich Dokumente
Kultur Dokumente
through all distribution channels. Consult your Distributor for availability and shipping information. Since Trane has a policy of continuous product improvement, it reserves the right to change design and specification without notice.
Table of Contents
Product Family
Model Nomenclature Model Nomenclature Accessories
Page No.
Page No.
XL80 Induced Draft Upflow/Horizontal (TUD2) ............................ FU-8 XL80 Induced Draft Downflow/Horizontal (TDD2) ........................ FU-9 XV80 Variable Speed (TUD,TDD) .............................................. FU-10 XB90 Upflow/Horizontal (TUC1) ................................................ FU-11 XB90 Downflow/Horizontal (TDC1) ............................................ FU-12 XR90 Direct Vent/ Non-Direct Upflow/Horizontal (TUX1) ........... FU-13 XR90 Direct Vent/ Non-Direct Downflow/Horizontal (TDX1) ....... FU-14 XT90 Direct Vent/ Non-Direct Upflow/Horizontal (TUX1-H) ........ FU-15 XT90 Direct Vent/ Non-Direct Downflow/Horizontal (TDX1-H) ... FU-16 XL90 Two Stage Upflow/Horizontal (TUX2) ................................ FU-17 XL90 Two Stage Downflow/Horizontal (TDX2) ........................... FU-18 XV90 Two Stage Variable Speed Upflow/Horizontal (TUY) ........ FU-19 XV90 Two Stage Variable Speed Downflow/Horizontal (TDY) .... FU-20 Special Use Furnace Accessories ............................................. FU-21 Quick Reference- Upflow/Horizontal .......................................... FU-23 Quick Reference- Downflow/ Horizontal ..................................... FU-25 Variable Speed High Efficiency Oil Furnaces ............................. FU-27 High Efficiency Oil Furnaces ...................................................... FU-28 Coil Enclosures .......................................................................... FU-29 Heat Pump/ Cooling Coil Nomenclatures ............................. FU-30-31 Aluminum High Efficiency Cased Coils (2TXC) .......................... FU-32 High Efficiency Cased Comfort Coils (TXC, 2/4TXF) ............. FU-33 High Efficiency Cased Comfort Coils for R-410A (RXC, RXA) FU-34 Reversible Cased Comfort Coils (2TXC) ................................ FU-35 Split System Cased Comfort Coils (2/4TXC) .......................... FU-36 Split System Cooling Only Cased Coils (2/4CXC) ..................... FU-37 Split System Cooling Only Uncased Coils (2/4CXA) .................. FU-38 Reversible Aluminum Cased Comfort Coils (2TXC) .............. FU-39 Split System Aluminum Cased Comfort Coils (2/4TXC) ........ FU-40 Split System Cooling Only Aluminum Cased Coils (2/4CXC) ..... FU-41 Split System Cooling Only Aluminum Uncased Coils (2/4CXA) . FU-42 Comfort Coils Dual Circuit Cased Coils (TXC) ....................... FU-43
AIR HANDLERS
Nomenclatures ......................................................................... AH-1-4 Variable Speed Convertible Air-Tite for R-410A (2TEE3) ........ AH-5 Variable Speed Convertible Air-Tite for R-410A (4TEE3) ........ AH-6 Variable Speed Accessories & Heaters (2/4TEE3) ..................... AH-7 Vertical Bottom and Front Return Air-Tite for R-22 (2TFB) ...... AH-8 Var. Speed Vertical Bottom/Front Return Air-Tite (2/4TFE) ...... AH-9 High Efficiency Convertible Air-Tite (2TEH) ........................... AH-10 High Efficiency Convertible Air-Tite (4TEH) ........................... AH-11 Convertible Air-Tite for R-22 (2TEC) ...................................... AH-12 Convertible Air-Tite for R-410A (4TEC) ................................. AH-13 Vertical Upflow and Horizontal Left Air-Tite for R-22 (2TGB) . AH-14 Convertible 5-10 Ton (TWE-A/B) ............................................... AH-15 Convertible 5-10 Ton Accessories (TWE-A/B) ........................... AH-16 Convertible 5-10 Ton Heaters (TWE-A/B) .................................. AH-18 Convertible 15-20 Ton (TWE-B) ................................................ AH-19 Convertible 15-20 Ton (TWE-E) ................................................ AH-20 Convertible 15-20 Ton Accessories (TWE-B/E) ......................... AH-21
PACKAGED COOLING
Nomenclature (4TCY) ................................................................ PC-1 2-4 Ton XL14c (4TCY) ................................................................ PC-2 2-4 Ton XL14c Heaters (4TCY) .................................................. PC-3 2-4 Ton XL14c Accessories (4TCY) ........................................... PC-4 1-1/2-5 Ton XB13c (4TCC) ......................................................... PC-5 1-1/2-5 Ton XB13c Heaters (4TCC) ............................................ PC-6 1-1/2-5 Ton XB13c Accessories (4TCC) ..................................... PC-7 1-1/2-5 Ton XL13c (4TCX) .......................................................... PC-8 1-1/2-5 Ton XL13c Heaters (4TCX) ............................................. PC-9 1-1/2-5 Ton XL13c Accessories (4TCX) .................................... PC-10 Nomenclature (TCK-B) .............................................................. PC-11 2-3-1/2 Ton (TCK-B) .................................................................. PC-12 2-5 Ton XE 1300 (TCH-C, TCH-F) ............................................. PC-13 2-3-1/2 Ton XE 1300 Comfort Controls (TCH-C) ....................... PC-14 Nomenclature Precedent Packaged Cooling ......................... PC-15 3-10 Ton (TSC) .......................................................................... PC-16 3-10 Ton (THC) .......................................................................... PC-17 3-10 Ton Heaters (TSC, THC) ................................................... PC-18
Table of Contents
Product Family PACKAGED COOLING (continued)
3-10 Ton Options (TSC, THC) .............................................. PC-19-23 3-5 Ton Accessory Heaters (TSC, THC) ................................... PC-24 6-10 Ton Accessory Heaters (TSC, THC) ................................. PC-25 3-10 Ton Accessories (TSC, THC) ....................................... PC-26-27 3-10 Ton Zone Sensors Thermostats (TSC, THC) ..................... PC-28 Nomenclature Precedent Packaged Cooling 13 SEER ......... PC-29 3-5 Ton 13 SEER (THC) ............................................................ PC-30 3-5 Ton Options 13 SEER (THC) ......................................... PC-31-33 3-5 Ton Accessory Heaters 13 SEER (THC) ............................ PC-34 3-5 Ton Accessories 13 SEER (THC) ....................................... PC-35 3-5 Ton Zone Sensors Thermostats 13 SEER (THC) ................ PC-36 Nomenclature Precedent Packaged Cooling R-410A ............ PC-37 3-5 Ton R-410A (TSC) ............................................................... PC-38 3-5 Ton Options R-410A (TSC) ............................................ PC-39-41 3-5 Ton Accessory Heaters R-410A (TSC) ............................... PC-42 3-5 Ton Accessories R-410A (TSC) .......................................... PC-43 3-5 Ton Zone Sensors Thermostats R-410A (TSC) ................... PC-44 12-1/2 Ton (TCH, TCD150D) ..................................................... PC-45 12-1/2 Ton Heaters (TCH, TCD150D) ....................................... PC-46 12-1/2 Ton Accessories (TCH, TCD150D) ................................ PC-47 15 Ton (TCH, TCD180B) ........................................................... PC-48 15 Ton Heaters (TCH, TCD180B) .............................................. PC-49 15 Ton Accessories (TCH, TCD180B) ....................................... PC-50 17-1/2 Ton (TCH, TCD210C) ..................................................... PC-51 17-1/2 Ton Heaters (TCH, TCD210C) ...................................... PC-52 17-1/2 Ton Accessories (TCH, TCD210C) ............................... PC-53 20 Ton (TCH, TCD240B) ........................................................... PC-54 25 Ton (TCH, TCD300B) ........................................................... PC-55 20 25 Ton Heaters (TCH, TCD240 - 300B) ........................... PC-56 20 25 Ton Accessories (TCH, TCD240 - 300B) .................... PC-57 12-1/2 Ton (TCH, TCD150E) ..................................................... PC-58 12-1/2 Ton Heaters (TCH, TCD150E) ........................................ PC-59 12-1/2 Ton Accessories (TCH, TCD150E) ................................. PC-60 15 Ton (TCH, TCD180E) ........................................................... PC-61 15 Ton Heaters (TCH, TCD180E) .............................................. PC-62 15 Ton Accessories (TCH, TCD180E) ....................................... PC-63 17-1/2 Ton (TCH, TCD210E) ..................................................... PC-64 17-1/2 Ton Heaters (TCH, TCD210E) ....................................... PC-65 17-1/2 Ton Accessories (TCH, TCD210E) ................................ PC-66 20 Ton (TCH, TCD240E) ........................................................... PC-67 12-1/2 25 Ton Zone Sensors (Micro Thermostats) ............... PC-68 12-1/2 Ton (TCH, TCD151C) ................................................ PC-69-70 12-1/2 Ton Heaters (TCH, TCD151C) ....................................... PC-71 12-1/2 Ton Accessories (TCH, TCD,TFD151C) ......................... PC-72 15 Ton (TCH, TCD,TFD181C) .............................................. PC-73-74 15 Ton Heaters (TCH, TCD181C) ............................................. PC-75 17-1/2 Ton (TCH, TCD211C) ................................................ PC-76-77 20 Ton (TCH, TCD241C) ...................................................... PC-78-79 25 Ton (TCH, TCD301C) ........................................................... PC-80 17-1/2 25 Ton Heaters (TCH, TCD211 - 301C) ..................... PC-81 15 25 Ton Accessories (TCH, TCD181 - 301C) .................... PC-82 12-1/2 25 Ton Thermostats (Zone Sensors) ......................... PC-83
Page No.
Page No.
3, 5 Ton XL/XE 1600 Comfort Controls, Accessories (YCZ-F) .... PG-8 2-5 Ton XL 1400 (YCY-G) ............................................................ PG-9 2-5 Ton XL 1400 Accessories (YCY-G) ..................................... PG-10 Nomenclature Precedent Convertible Pkg. Gas/Electric ........ PG-11 3-5 Ton (YSC) ............................................................................ PG-12 6-10 Ton (YSC) ..................................................................... PG-13-14 3-5 Ton (YHC) ........................................................................... PG-15 6-10 Ton (YHC) ......................................................................... PG-16 3-10 Ton Options (YSC, YHC) .............................................. PG-17-21 3-10 Ton Accessories (YSC, YHC) ....................................... PG-22-23 3-10 Ton Zone Sensors Thermostats (YSC, YHC) .................... PG-24 Nomenclature Precedent Conver. Pkg. Gas/Electric 13 SEER PG-25 3-5 Ton 13 SEER (YHC) ............................................................ PG-26 3-5 Ton Options 13 SEER (YHC) ......................................... PG-27-30 3-5 Ton Accessories 13 SEER (YHC) ....................................... PG-31 3-5 Ton Zone Sensors Thermostats 13 SEER (YHC) ............... PG-32 Nomenclature Precedent Conver. Pkg. Gas/Electric R-410A PG-33 3-5 Ton R-410A (YSC) .............................................................. PG-34 3-5 Ton Options R-410A (YSC) ............................................ PG-35-38 3-5 Ton Accessories R-410A (YSC) .......................................... PG-39 3-5 Ton Zone Sensors Thermostats R-410A (YSC) .................. PG-40 12-1/2 Ton (YCH150D) .............................................................. PG-41 12-1/2 Ton (YCD150D) .............................................................. PG-42 12-1/2 Ton Accessories (YCH, YCD150D) ................................ PG-43 15 Ton (YCH180B) .................................................................... PG-44 15 Ton (YCD180B) .................................................................... PG-45 15 Ton Accessories (YCH, YCD180B) ...................................... PG-46 17-1/2 Ton (YCH210C) .............................................................. PG-47 17-1/2 Ton (YCD210C) .............................................................. PG-48 17-1/2 Ton Accessories (YCH, YCD210C) ................................ PG-49 20 Ton (YCH240B) .................................................................... PG-50 20 Ton (YCD240B) .................................................................... PG-51 25 Ton (YCH300B) .................................................................... PG-52 25 Ton (YCD300B) .................................................................... PG-53 20 25 Ton Accessories (YCH,YCD 240-300B) ..................... PG-54 12-1/2 Ton (YCD150E) .............................................................. PG-55 12-1/2 Ton (YCH150E) .............................................................. PG-56 12-1/2 Ton Accessories (YCH, YCD150E) ................................ PG-57 15 Ton (YCH180E) .................................................................... PG-58 15 Ton (YCD180E) .................................................................... PG-59 15 Ton Accessories (YCH, YCD180E) ...................................... PG-60 17-1/2 Ton (YCH210E) .............................................................. PG-61 17-1/2 Ton (YCD210E) .............................................................. PG-62 17-1/2 Ton Accessories (YCH, YCD210E) ................................ PG-63 20 Ton (YCH240E) .................................................................... PG-64 20 Ton (YCD240E) .................................................................... PG-65 12-1/2 25 Ton Zone Sensors (Micro Thermostats) ................ PG-66 12-1/2 Ton (YCH151C) .............................................................. PG-67 12-1/2 Ton (YCD,YFD151C) ................................................. PG-68-70 12-1/2 Ton Accessories (YCH, YCD151C) ................................ PG-71 15 Ton (YCH181C) .................................................................... PG-72 15 Ton (YCD,YFD181C) ....................................................... PG-73-75 17-1/2 Ton (YCH211C) .............................................................. PG-76 17-1/2 Ton (YCD211C) ......................................................... PG-77-78 20 Ton (YCH241C) .................................................................... PG-79 20 Ton (YCD,YFD241C) ....................................................... PG-80-81 25 Ton (YCH, YCD301C) ...................................................... PG-82-83 15 25 Ton Accessories (YCH, YCD181-301C) ...................... PG-84 12-1/2 25 Ton Zone Sensors (Micro Thermostats) ................ PG-85
PACKAGED GAS/ELECTRIC
2-5 Ton XB13c (2YCC) ............................................................... PG-1 1-1/2-5 Ton XB13c (4YCC) ......................................................... PG-2 1-1/2-5 Ton XB13c Accessories (2/4YCC) .................................. PG-3 2-5 Ton XL13c (2YCX) ................................................................ PG-4 1-1/2-5 Ton XL13c (4YCX) .......................................................... PG-5 1-1/2-5 Ton XL13c Accessories (2/4YCX) ................................... PG-6 3, 5 Ton XL/XE 1600 (YCZ-F) ..................................................... PG-7
Table of Contents
Page No.
Page No.
1-1/2-5 Ton XL13c Accessories (2/4WCX) ................................ PH-10 2-3-1/2 Ton 13 SEER (WCX-B) ................................................. PH-11 3, 5 Ton XL/XE 1600 (WCZ-F) .................................................. PH-12 3, 5 Ton XL/XE 1600 Comfort Controls, Accessories (WCZ-F) . PH-13 3-5 Ton XL/XE 1600 Heaters (WCZ-F) ...................................... PH-14 2-5 Ton XE 1300 (WCH-C, WCH-F1) ........................................ PH-15 2-3-1/2 Ton XE 1300 Accessories (WCH-B) ............................. PH-16 Nomenclature Precedent Packaged Heat Pumps ................. PH-17 3-10 Ton (WSC) ......................................................................... PH-18 3-10 Ton Heaters (WSC) ........................................................... PH-19 3-10 Ton Options (WSC) ...................................................... PH-20-23 3-5 Ton Accessory Heaters (WSC) ........................................... PH-24 6-10 Ton Accessory Heaters (WSC) ......................................... PH-25 3-10 Ton Accessories (WSC) ............................................... PH-26-27 3-10 Ton Zone Sensors (WSC) ................................................. PH-28 Nomenclature Precedent Packaged Heat Pumps R-410A .... PH-29 3-5 Ton Heaters R-410A (WSC) ................................................ PH-30 3-5 Ton Options R-410A (WSC) ........................................... PH-31-34 3-5 Ton Accessory Heaters R-410A (WSC) .............................. PH-35 3-5 Ton Accessories R-410A (WSC) ......................................... PH-36 3-5 Ton Zone Sensors R-410A (WSC) ...................................... PH-37 12-1/2 Ton (WCH, WCD150B) ................................................... PH-38 12-1/2 Ton Heaters (WCH, WCD150B) ..................................... PH-39 12-1/2 Ton Accessories (WCH, WCD150B) .............................. PH-40 15 Ton (WCH, WCD180B) ......................................................... PH-41 15 Ton Heaters (WCH, WCD180B) ........................................... PH-42 15 Ton Accessories (WCH, WCD180B) .................................... PH-43 20 Ton (WCH, WCD240B) ......................................................... PH-44 20 Ton Heaters (WCH, WCD240B) .......................................... PH-45 20 Ton Accessories (WCH, WCD240B) .................................... PH-46 12-1/2 20 Zone Sensors (Micro Thermostats) ...................... PH-47
EXTENDED WARRANTY
Model Number Index ................................................................... WA-1 1 6 Ton Complete System (Residential) .................................. WA-2 1 5 Ton Condensing Unit (Residential) .................................... WA-4 1 5 Ton Compressor Only (Residential) .................................. WA-5 1 5 Ton Furnace, Air Handler & Heat Exchanger (Residential) ................................................... WA-6 1 25 Ton Complete System (Commercial) .............................. WA-7 1 20 Ton Condensing Unit (Commercial) ................................ WA-9 1 25 Ton Compressor Only (Commercial) ............................. WA-10 1 25 Ton Furnace, Air Handler & Heat Exchanger (Commercial) ................................................ WA-11 1 25 Ton Accessory (Residential or Commercial) ................. WA-13 1 25 Ton National Account First Year Labor (Commercial) .... WA-14 1 6 Ton Water Source Package System (Residential) ........... WA-15 1 6 Ton Water Source Package System (Commercial) ......... WA-16 1 25 Ton No Parts Mark-up (Residential or Commercial) ...... WA-17 General Notes ........................................................................... WA-18 Numerical List of Product Coverage ..................................... WA-19-53 Optional Extended Warranty Benefits ................................... WA-54-55
1 4
2 T
3 T
4 X
5 4
6 0
7 3
8 6
9 A
10 11 12 13 14 15 1 0 0 0 A A
Refrigerant Type 2 R-22 4 R-410A Trane Product Type W Split Heat Pump T Split Cooling Product Family Z Leadership - 2 Stage X Leadership R Replacement/Retail B Basic A Light Commercial Family SEER ~ 0 ~ 10 3 ~ 13 8 = 18 = = 1 ~ 11 4 ~ 14 = = 2 ~ 12 6 ~ 16 = =
Secondary Function
Power Supply 1 = 200-230/1/60 or 208-230/1/60 3 = 200-230/3/60 4 = 460/3/60 Major Design Modifications Nominal Capacity in 000's of BTUH's Split System Connections 1-6 Tons 0 Brazed
A
SERVICE DIGIT (WHEN REQUIRED)
DENOTES: ACCESSORY
MINOR DESIGN SEQUENCE ACCESSORY TO UNIT MATCH-UP (WHEN REQUIRED) ACCESSORY TYPE Example: ASCT = ANTI-CYCLE TIMER BARM = BAROMETRIC RELIEF BASE = SUBBASE CCHT = CRANKCASE HEATER CLE = COIL ENCLOSURE CURB = ROOFCURB DMPR = DAMPER ECON = ECONOMIZER ENTH = ENTHALPY CONTROL FLTR = FILTER GARD = COIL GUARD GRLE = RETURN AIR GRILLE HALT = HIGH ALTITUDE KIT HTRA = ELECTRIC HEATER (DIGIT 7 IS USED TO DIFFERENTIATE THE PRODUCTS ACCESSORY IS USED WITH) HSMT = HIGH STATIC MOTOR HGBP = HOT GAS BYPASS CONTROL ISLT = ISOLATOR KSKT = START ACCESSORY KIT LOAM = LOW AMBIENT LPKT = L.P. KIT LSDR = LOW STATIC DRIVE NXKT = NOx ROD ACCESSORY KIT PANL = PANEL PLNM = PLENUM RLAY = RELAY SENS = SENSOR SPEK = SINGLE POWER ENTRY KIT STAT = THERMOSTAT TBKT = THRU BASE UTILITY KIT TEST = TEST ACCESSORY TFMR = TRANSFORMER TWIN = TWINNING KIT WATR = HYDRONIC HEAT COILS WRKT = WIRE KIT 2STG = 2 STAGE GAS
MAJOR DESIGN SEQUENCE NUMBERS ARE SEQUENTIALLY ASSIGNED EXCEPT FOR ELECTRIC HEATERS. ON ELECTRIC HEATS DIGIT 8 IS USED TO IDENTIFY VOLTAGE & DIGIT 9 & 10 ARE USED TO IDENTIFY CAPACITY IN KW'S
Accessories:
Model Number Extended Warranties Controls AY28X079 TAYASCT501A1 BAYLEGS002 BAYLEGS003 BAYVDTA004 BAYISLT101 BAYECMT001 Description (See Extended Warranty Section) (See Control Section) Evap. Defrost Control Kit Anti-Short Cycle Timer Snow/Sand Legs 4" Extension Vertical Discharge Air Kit Base 4 Rubber Isolators Extreme Condition Mounting Kit Used With Mfg. Shipping Plant Weight
All Cooling Models All Cooling Models All Cooling Models All Cooling Models All Cooling Models All Cooling Models All Cooling Models
TY TY TY TY TY TY TY
1 2 1 1 10 1 2
Two ClimatuffTM compressors Efficiency up to 19.5 SEER All Aluminum Spine FinTM coil WeatherGuardTM II top shields unit WeatherGuardTM fasteners Quick-SessTM cabinet, service access and refrigerant connections with full coil protection DuraTuffTM base, fast complete drain, weather proof Comfort"R"TM mode approved Glossy corrosion resistant finish Internal Compressor high/low pressure & temperature protection Start kit standard 50 or 100% capacity modulation Compressor sump heat Liquid line filter/drier Tarpaulin gray cabinet with anthracite gray top
Low sound with advanced fan system and compressor sound insulator Variable speed fan motor Electronic compressor control Seacoast shield Service valve cover R-22 refrigerant 10 year limited warranty on compressor, coil, and internal functional parts (Residential Use) Extended warranties available S.E.E.T. design testing 100% line run test Low ambient cooling to 55F as shipped Low ambient cooling to 30F with AY28X079
SC 1
Accessories:
Model Number Extended Warranties Controls AY28X079 BAYKSKT260 BAYLEGS002 BAYLEGS003 BAYVDTA003 BAYVDTA004 BAYECMT001 BAYCCHT301 BAYISLT101 TAYASCT501A Description (See Extended Warranty Section) (See Control Section) Evap. Defrost Control Kit Start Kit Snow/Sand Legs 4" Extension Vertical Discharge Air Kit Base 3 Vertical Discharge Air Kit Base 4 Extreme Condition Mounting Kit Crankcase Heater Kit Rubber Isolators Anti-Short Cycle Timer Used With Mfg. Shipping Plant Weight
All Cooling Models 3 - 4 Ton Models All Cooling Models All Cooling Models 2 Ton Models 3 - 5 Models All Cooling Models 2 - 4 Ton Models All Cooling Models All Cooling Models
TY TY TY TY TY TY TY TY TY TY
1 1 1 1 10 10 2 1 1 1
Climatuff staged scroll compressor Efficiency up to 17.15 SEER All aluminum Spine FinTM coil WeatherGuardTM II top shields unit WeatherGuardTM fasteners Quick-SessTM cabinet, service access and refrigerant connections with full coil protection DuraTuffTM base, fast complete drain, weather proof Comfort"R"TM mode approved Glossy corrosion resistant finish Internal compressor high/low pressure & temperature protection 024 ships with start kit 060 ships with start kit and sump heat Liquid line filter-drier Tarpaulin gray cabinet with anthracite gray top
Low sound with advanced fan system and compressor sound insulator High pressure switch XL Seacoast shield Service valve cover R-410A refrigerant 70 or 100% capacity modulation 10 year limited warranty on compressor, coil, and internal functional parts (Residential Use) Extended warranties available S.E.E.T. design testing 100% line run test Low ambient cooling to 55F as shipped Low ambient cooling to 30F with AY28X079
SC 2
Accessories:
Model Number Extended Warranties Controls AY28X079 BAYLEGS002 BAYLEGS003 BAYVDTA004 TAYASCT501A1 BAYKSKT260 BAYECMT001 BAYISLT101 Description (See Extended Warranty Section) (See Control Section) Evap. Defrost Control Kit Snow/Sand Legs 4" Extension Vertical Discharge Air Kit Base 4 Anti-Short Cycle Timer Start Kit Extreme Condition Mounting Kit Rubber Isolators Used With Mfg. Plant Shipping Weight
All Cooling Models All Cooling Models All Cooling Models 2 - 4 Models All Cooling Models 2 - 4 Ton Models All Cooling Models All Cooling Models
TY TY TY TY TY TY TY TY
1 1 1 10 1 1 2 1
Climatuff compressor Efficiency up to 16.25 SEER All aluminum Spine FinTM coil WeatherGuardTM II top shields unit WeatherGuardTM fasteners Quick-SessTM cabinet, service access and refrigerant connections with full coil protection DuraTuffTM base, fast complete drain, weather proof Comfort"R"TM mode approved Glossy corrosion resistant finish Internal compressor high/low pressure & temperature protection Liquid line filter-drier Tarpaulin gray cabinet with anthracite gray top
Low sound with advanced fan system and compressor sound insulator XL Seacoast shield Service valve cover R-22 refrigerant 10 year limited warranty on compressor, coil, and internal functional parts (Residential Use) Extended warranties available S.E.E.T. design testing 100% line run test Low ambient cooling to 55F as shipped Low ambient cooling to 30F with AY28X079
SC 3
Accessories:
Model Number Extended Warranties Controls AY28X079 TAYASCT501A1 BAYKSKT260 BAYECMT001 BAYLEGS002 BAYLEGS003 BAYVDTA003 BAYVDTA004 BAYCCHT301 BAYISLT101 Description (See Extended Warranty Section) (See Control Section) Evap. Defrost Control Kit Anti-Short Cycle Timer Start Kit Extreme Condition Mounting Kit Snow/Sand Legs 4" Extension Vertical Discharge Air Kit Base 3 Vertical Discharge Air Kit Base 4 Crankcase Heater Kit Rubber Isolators Used With Mfg. Plant Shipping Weight
All Cooling Models All Cooling Models 2.5 - 4 Ton Models All Cooling Models All Cooling Models All Cooling Models 2 - 3 Ton Models 3.5 - 5 Models 2.5 - 3 Ton Models All Cooling Models
TY TY TY TY TY TY TY TY TY TY
1 1 1 2 1 1 10 10 1 1
Climatuff compressor Efficiency up to 15.0 SEER All aluminum Spine FinTM coil WeatherGuardTM II top shields unit WeatherGuardTM fasteners Quick-SessTM cabinet, service access and refrigerant connections with full coil protection DuraTuffTM base, fast complete drain, weather proof Comfort"R"TM mode approved Glossy corrosion resistant finish Internal compressor high/low pressure & temperature protection Tarpaulin gray cabinet with anthracite gray top Low sound with advanced fan system and compressor sound insulator
XL Seacoast shield 018, 024 & 060 ship with start kit Liquid line filter-drier Service valve cover R-22 refrigerant 10 year limited warranty on compressor, coil, and internal functional parts (Residential Use) Extended warranties available S.E.E.T. design testing 100% line run test Low ambient cooling to 55F as shipped Low ambient cooling to 30F with AY28X079
SC 4
Accessories:
Model Number Extended Warranties Controls AY28X079 TAYASCT501A1 BAYKSKT260 BAYLEGS002 BAYLEGS003 BAYVDTA003 BAYVDTA004 BAYECMT001 BAYCCHT301 BAYISLT101 Description (See Extended Warranty Section) (See Control Section) Evap. Defrost Control Kit Anti-Short Cycle Timer Start Kit Snow/Sand Legs 4" Extension Vertical Discharge Air Kit Base 3 Vertical Discharge Air Kit Base 4 Extreme Condition Mounting Kit Crankcase Heater Kit Rubber Isolators Used With Mfg. Plant Shipping Weight
All Cooling Models All Cooling Models 2.5 - 4 Ton Models All Cooling Models All Cooling Models 2 - 3 Ton Models 3.5 - 5 Models All Cooling Models 2.5 - 5 Ton Models All Cooling Models
TY TY TY TY TY TY TY TY TY TY
1 1 1 1 1 10 10 2 1 1
Climatuff compressor Efficiency up to 15.0 SEER All aluminum Spine FinTM coil WeatherGuardTM II top shields unit WeatherGuardTM fasteners Quick-SessTM cabinet, service access and refrigerant connections with full coil protection DuraTuffTM base, fast complete drain, weather proof Comfort"R"TM mode approved Glossy corrosion resistant finish Internal compressor high/low pressure & temperature protection Tarpaulin gray cabinet with anthracite gray top Low sound with advanced fan system and compressor sound insulator
XL Seacoast shield High pressure switch 018, 024 & 060 ship with start kit Liquid line filter-drier Service valve cover R-410A refrigerant 10 year limited warranty on compressor, coil, and internal functional parts (Residential Use) Extended warranties available S.E.E.T. design testing 100% line run test Low ambient cooling to 55F as shipped Low ambient cooling to 30F with AY28X079
SC 5
Accessories:
Model Number Extended Warranties Controls AY28X079 TAYASCT501A1 BAYKSKT260 BAYECMT001 BAYCCHT301 BAYLOAM103 BAYLEGS002 BAYLEGS003 BAYSEAC001 BAYISLT101 Description (See Extended Warranty Section) (See Control Section) Evap. Defrost Control Kit Anti-Short Cycle Timer Start Kit Extreme Condition Mounting Kit Crankcase Heater Kit Low Ambient Kit Snow/Sand Legs 4" Extension Seacoast Kit Rubber Isolators Used With Mfg. Plant Shipping Weight
All Cooling Models All Cooling Models 2.5 - 4 Ton Models All Cooling Models 2.5 - 3 Ton Models All Cooling Models All Cooling Models All Cooling Models All Cooling Models All Cooling Models
TY TY TY TY TY TY TY TY TY TY
1 1 1 2 1 1 1 1 1 1
Climatuff compressor Efficiency up to 14.00 SEER All aluminum Spine FinTM coil WeatherGuardTM fasteners Quick-SessTM cabinet, easy service access and refrigerant connections with full coil protection DuraTuffTM base, fast complete drain, weather proof Comfort"R"TM mode approved Glossy corrosion resistant finish Internal compressor high/low pressure & temperature protection 018, 024 & 060 ship with start kit Liquid line filter-drier
Tarpaulin gray cabinet with anthracite gray badge and cap Service valve cover R-22 refrigerant 10 year limited warranty on compressor, coil, 5 years internal functional parts (Residential Use) Extended warranties available S.E.E.T. design testing 100% line run test Low ambient cooling to 55F as shipped Low ambient cooling to 30F with AY28X079
SC 6
Accessories:
Model Number Extended Warranties Controls AY28X079 TAYASCT501A1 BAYKSKT260 BAYECMT001 BAYCCHT301 BAYLOAM103 BAYLEGS002 BAYLEGS003 BAYSEAC001 BAYISLT101 Description (See Extended Warranty Section) (See Controls Section) Evap. Defrost Control Kit Anti-Short Cycle Timer Start Kit Extreme Condition Mounting Kit Crankcase Heater Kit Low Ambient Kit Snow/Sand Legs 4" Extension Seacoast Kit Rubber Isolators Used With Mfg. Plant Shipping Weight
All Cooling Models All Cooling Models 2.5 - 4 Ton Models All Cooling Models 2.5 - 5 Ton Models All Cooling Models All Cooling Models All Cooling Models All Cooling Models All Cooling Models
TY TY TY TY TY TY TY TY TY TY
1 1 1 2 1 1 1 1 1 1
Climatuff compressor Efficiency up to 14.00 SEER All aluminum Spine FinTM coil WeatherGuardTM fasteners Quick-SessTM cabinet, easy service access and refrigerant connections with full coil protection DuraTuffTM base, fast complete drain, weather proof Comfort"R"TM mode approved Glossy corrosion resistant finish Internal compressor high/low pressure & temperature protection 018, 024 & 060 ship with start kit Liquid line filter-drier
Tarpaulin gray cabinet with anthracite gray badge and cap High pressure switch Service valve cover R-410A refrigerant 10 year limited warranty on compressor, coil, 5 years internal functional parts (Residential Use) Extended warranties available S.E.E.T. design testing 100% line run test Low ambient cooling to 55F as shipped Low ambient cooling to 30F with AY28X079
SC 7
Accessories:
Model Number Extended Warranties Controls AY28X079 TAYASCT501A1 BAYKSKT260 BAYECMT001 BAYCCHT300 BAYCCHT301 BAYLOAM103 BAYLEGS002 BAYLEGS003 BAYSEAC001 BAYISLT101 Description (See Extended Warranty Section) (See Control Section) Evap. Defrost Control Kit Anti-Short Cycle Timer Start Kit Extreme Condition Mounting Kit Crankcase Heater Kit Crankcase Heater Kit Low Ambient Kit Snow/Sand Legs 4" Extension Seacoast Kit Rubber Isolators Used With Mfg. Plant Shipping Weight
All Cooling Models All Cooling Models 3 Ton Models All Cooling Models 1.5, 2, 2.5, 3.5 & 4 Ton Models 3 Ton Models All Cooling Models All Cooling Models All Cooling Models All Cooling Models All Cooling Models
TY TY TY TY TY TY TY TY TY TY TY
1 1 1 2 1 1 1 1 1 1 1
Climatuff compressor Efficiency up to 14.00 SEER All aluminum Spine FinTM coil WeatherGuardTM fasteners Quick-SessTM cabinet, easy service access and refrigerant connections with full coil protection DuraTuffTM base, fast complete drain, weather proof Comfort"R"TM mode approved Glossy corrosion resistant finish Internal compressor high/low pressure & temperature protection 018, 024, 030, 042, 048 & 060 ship with start kit Liquid line filter-drier Tarpaulin gray cabinet with anthracite gray badge and cap
Service valve cover R-22 refrigerant 10 year limited warranty on compressor, coil, 5 years internal functional parts (Residential Use) Extended warranties available S.E.E.T. design testing 100% line run test Low ambient cooling to 55F as shipped Low ambient cooling to 30F with AY28X079 Low ambient cooling to 0F with BAYLOAM103
SC 8
Accessories:
Model Number Extended Warranties Controls AY28X079 TAYASCT501A1 BAYKSKT260 BAYECMT001 BAYCCHT300 BAYCCHT301 BAYSDEN003 BAYLEGS002 BAYLEGS003 BAYSEAC001 BAYISLT101 BAYLOAM103 Description (See Extended Warranty Section) (See Control Section) Evap. Defrost Control Kit Anti-Short Cycle Timer Start Kit Extreme Condition Mounting Kit Crankcase Heater Kit Crankcase Heater Kit Sound Enclosure Small Scroll Snow/Sand Legs 4" Extension Seacoast Kit Rubber Isolators Low Ambient Kit Used With Mfg. Shipping Plant Weight
All Cooling Models TY All Cooling Models TY 3, 3.5 & 4 Ton Models TY All Cooling Models TY 1.5, 2 & 2.5 Ton Models TY 3, 3.5 & 4 Ton Models TY 3 - 4 Ton Models TY All Cooling Models TY All Cooling Models TY All Cooling Models TY All Cooling Models TY All Cooling Models TY
1 1 1 2 1 1 8 1 1 1 1 1
Climatuff compressor Efficiency up to 14.00 SEER All aluminum Spine FinTM coil WeatherGuardTM fasteners Quick-SessTM cabinet, easy service access and refrigerant connections with full coil protection DuraTuffTM base, fast complete drain, weather proof Comfort"R"TM mode approved Glossy corrosion resistant finish Internal compressor high/low pressure & temperature protection 018, 024, 030 & 060 ship with start kit Liquid line filter-drier Tarpaulin gray cabinet with anthracite gray badge & cap High pressure switch Service Valve Cover R-410A refrigerant
10 year limited warranty on compressor, coil, 5 years on internal functional parts (Residential Use) 5 year limited warranty on compressor, coil, 1 year on parts (Commercial Use) Extended warranties available S.E.E.T design testing 100% line run test Low ambient cooling to 55F as shipped Low ambient cooling to 30F with AY28X079 Low ambient cooling to 0F with BAYLOAM103
SC 9
Accessories:
Model Number Extended Warranties Controls AY28X079 TAYASCT501A1 BAYKSKT260 BAYECMT001 BAYCCHT300 BAYCCHT301 BAYSDEN001 BAYSDEN004 BAYLOAM103 BAYLEGS002 BAYLEGS003 BAYSEAC001 BAYISLT101 Description (See Extended Warranty Section) (See Control Section) Evap. Defrost Control Kit Anti-Short Cycle Timer Start Kit Extreme Condition Mounting Kit Crankcase Heater Crankcase Heater Sound Enclosure 1 Cycle Recip Sound Enclosure Large Scroll Low Ambient Kit Snow/Sand Legs 4" Extension Seacoast Kit Rubber Isolators Used With Mfg. Plant Shipping Weight
All Cooling Models All Cooling Models 3 Ton Models All Cooling Models 1.5, 2, 2.5, 3.5 & 4 Ton Models 3 Ton Models 1.5 - 2.5 Ton Models 5 Ton Models All Cooling Models All Cooling Models All Cooling Models All Cooling Models All Cooling Models
TY TY TY TY TY TY TY TY TY TY TY TY TY
1 1 1 2 1 1 8 8 1 1 1 1 1
Climatuff compressor Efficiency up to 13.25 SEER All aluminum Spine FinTM coil WeatherGuardTM fasteners Quick-SessTM cabinet, easy service access and refrigerant connections with full coil protection DuraTuffTM base, fast complete drain, weather proof Comfort"R"TM mode approved Glossy corrosion resistant finish Internal compressor high/low pressure & temperature protection 018, 024,030,042,048 & 060 ship with start kit Liquid line filter-drier Polyslate gray cabinet with anthracite gray badge & cap
R-22 refrigerant 5 year limited warranty on compressor, coil, and 5 years on internal functional parts (Residential Use) Extended warranties available S.E.E.T. design testing 100% line run test Low ambient cooling to 55F as shipped Low ambient cooling to 30F with AY28X079 Low ambient cooling to 0F with BAYLOAM103
SC 10
Accessories:
Model Number Extended Warranties Controls AY28X079 TAYASCT501A1 BAYKSKT260 BAYECMT001 BAYCCHT300 BAYCCHT301 BAYSDEN003 BAYSDEN004 BAYLEGS002 BAYLEGS003 BAYSEAC001 BAYISLT101 BAYLOAM103 Description (See Extended Warranty Section) (See Control Section) Evap. Defrost Control Kit Anti-Short Cycle Timer Start Kit Extreme Condition Mounting Kit Crankcase Heater Crankcase Heater Sound Enclosure Small Scroll Sound Enclosure Large Scroll Snow/Sand Legs 4" Extension Seacoast Kit Rubber Isolators Low Ambient Kit Used With Mfg. Shipping Plant Weight
All Cooling Models All Cooling Models 3, 3.5 & 4 Ton Models All Cooling Models 1.5, 2, 2.5 Ton Models 3, 3.5 & 4 Ton Models 3 - 4 Ton Models 5 Ton Models All Cooling Models All Cooling Models All Cooling Models All Cooling Models All Cooling Models
TY TY TY TY TY TY TY TY TY TY TY TY TY
1 1 1 2 1 1 8 8 1 1 1 1 1
Climatuff compressor Efficiency up to 13.25 SEER All aluminum Spine FinTM coil WeatherGuardTM fasteners Quick-SessTM cabinet, easy service access and refrigerant connections with full coil protection DuraTuffTM base, fast complete drain, weather proof Comfort"R"TM mode approved Glossy corrosion resistant finish Internal compressor high/low pressure & temperature protection 018, 024,030 & 060 ship with start kit Liquid line filter-drier Polyslate gray cabinet with anthracite gray badge & cap
High pressure switch R-410A refrigerant 5 year limited warranty on compressor, coil, and 5 years on internal functional parts (Residential Use) Extended warranties available S.E.E.T. design testing 100% line run test Low ambient cooling to 55F as shipped Low ambient cooling to 30F with AY28X079 Low ambient cooling to 0F with BAYLOAM103
SC 11
Accessories:
Model Number Extended Warranties Controls AY28X079 BAY24X045 TAYASCT501A1 BAYECMT001 BAYSDEN001 BAYSDEN002 BAYSDEN003 BAYSDEN004 BAYLEGS002 BAYLEGS003 BAYSEAC001 BAYLOAM103 BAYISLT101 Description (See Extended Warranty Section) (See Control Section) Evap. Defrost Control Kit ID Fan Delay Kit Anti-Short Cycle Timer Extreme Condition Mounting Kit Sound Enclosure 1 Cycle Recip Sound Enclosure 2 Cycle Recip Sound Enclosure Small Scroll Sound Enclosure Large Scroll Snow/Sand Legs 4" Extension Seacoast Kit Low Ambient Kit Rubber Isolators Used With Mfg. Plant Shipping Weight
All Cooling Models All Cooling Models All Cooling Models All Cooling Models 2.5 Ton Models 3.5 - 4 Ton Models 3 Ton Models 5 Ton Models All Cooling Models All Cooling Models All Cooling Models All Cooling Models All Cooling Models
TY TY TY TY TY TY TY TY TY TY TY TY TY
1 1 1 2 8 8 8 8 1 1 1 1 1
Climatuff compressor All aluminum Spine FinTM coil WeatherGuardTM fasteners Quick-SessTM cabinet, service access and refrigerant connections with full coil protection DuraTuffTM base, fast complete drain, weather proof Comfort"R"TM mode approved Glossy corrosion resistant finish Internal compressor high/low pressure & temperature protection Compressor Sump Heat Liquid line filter-drier Polyslate gray cabinet with anthracite gray badge & cap Low pressure switch
R-22 refrigerant 5 year limited warranty on compressor, coil, and internal functional parts (Residential Use Only) 5 year limited warranty on compressor, coil, and 1 year on parts (Commercial Use Only) Extended warranties available S.E.E.T. design testing 100% line run test Low ambient cooling to 55F as shipped Low ambient cooling to 30F with AY28X079 Low ambient cooling to 0F with BAYLOAM103
SC 12
Accessories:
Model Number Extended Warranties Controls AY28X079 BAY24X045 TAYASCT501A1 BAYECMT001 BAYLEGS002 BAYLEGS003 BAYSDEN001 BAYSDEN003 BAYSDEN004 BAYSEAC001 BAYLOAM103 BAYISLT101 Description (See Extended Warranty Section) (See Control Section) Evap. Defrost Control Kit ID Fan Delay Kit Anti-Short Cycle Timer Extreme Condition Mounting Kit Snow/Sand Legs 4" Extension Sound Enclosure 1 Cycle Recip Sound Enclosure Small Scroll Sound Enclosure Large Scroll Seacoast Kit Low Ambient Kit Rubber Isolators Used With Mfg. Shipping Plant Weight
All Cooling Models All Cooling Models All Cooling Models All Cooling Models All Cooling Models All Cooling Models 2.5 Ton Models 3 - 4 Ton Models 5 Ton Models All Cooling Models All Cooling Models All Cooling Models
TY TY TY TY TY TY TY TY TY TY TY TY
1 1 1 2 1 1 8 8 8 1 1 1
Climatuff compressor All aluminum Spine FinTM coil WeatherGuardTM fasteners Quick-SessTM cabinet, service access and refrigerant connections with full coil protection DuraTuffTM base, fast complete drain, weather proof Comfort"R"TM mode approved Glossy corrosion resistant finish Internal compressor high/low pressure & temperature protection Liquid line filter-drier Polyslate gray cabinet with anthracite gray badge & cap R-410A refrigerant Low pressure switch High pressure switch
Compressor sump heat 5 year limited warranty on compressor, coil, and internal functional parts (Residential Use Only) 5 year limited warranty on compressor, coil, and 1 year on parts (Commercial Use Only) Extended warranties available S.E.E.T. design testing 100% line run test Low ambient cooling to 55F as shipped Low ambient cooling to 30F with AY28X079 Low ambient cooling to 0F with BAYLOAM103
SC 13
Accessories:
Model Number Extended Warranties Controls AY28X079 BAY24X045 TAYASCT501A1 BAYECMT001 BAYLOAM103 BAYLEGS002 BAYLEGS003 BAYSEAC001 BAYISLT101 Description (See Extended Warranty Section) (See Control Section) Evap. Defrost Control Kit ID Fan Delay Kit Anti-Short Cycle Timer Extreme Condition Mounting Kit Low Ambient Kit Snow/Sand Legs 4" Extension Seacoast Kit Rubber Isolators Used With
All Cooling Models All Cooling Models All Cooling Models All Cooling Models All Cooling Models All Cooling Models All Cooling Models All Cooling Models All Cooling Models
TY TY TY TY TY TY TY TY TY
1 1 1 2 1 1 1 1 1
Climatuff compressor All aluminum Spine FinTM coil WeatherGuardTM fasteners Quick-SessTM cabinet, service access and refrigerant connections with full coil protection DuraTuffTM base, fast complete drain, weather proof Comfort"R"TM mode approved Glossy corrosion resistant finish Internal compressor high/low pressure & temperature protection Compressor sump heat Liquid line filter-drier Polyslate gray cabinet with anthracite gray badge & cap Low pressure switch
R-22 refrigerant 5 year limited warranty on compressor, coil, and internal functional parts (Residential Use Only) 5 year limited warranty on compressor, coil, and 1 year on parts (Commercial Use Only) Extended warranties available S.E.E.T. design testing 100% line run test Low ambient cooling to 55F as shipped Low ambient cooling to 30F with AY28X079 Low ambient cooling to 0F with BAYLOAM103
SC 14
Mfg. Shipping Plant Weight SPR 370 SPR 370 SPR 370 SPR 370 SPR 370 SPR 370 SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR 443 443 443 443 443 443 370 370 370 370 370 370 443 443 443 443 443 443 370 370 370 370 370 370 443 443 443 443 443 443
Features:
(1) Trane 3-D Scroll compressor Single point power supply Compressor motor overload protection Control transformer High and low pressure cut-out switches Liquid line filter drier, factory installed Service valves with pressure taps Holding charge of Nitrogen Copper tube, aluminum plate fin coils Low ambient cooling to 50F as manufactured Low ambient cooling to 0F with accessory head pressure control Mounting/lifting rails under base Optional factory installed Black Epoxy Coil for corrosive resistance SC 15 UL listed and CSA certified 5 year compressor warranty
Power Supply
208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60
SC 16
Specifications: Dual Compressor With Dual Refrigerant Circuits (continued) Factory Capacity Uncrated Model Installed Power Cooling Dim. (in.) Number Option Supply (BTUH) H W L
TTA120BW00E TTA120BW0SE TTA120BW0RE TTA120BW0TE TTA120BW0UE TTA120BW0WE TTA150BW00E TTA150BW0SE TTA150BW0RE TTA150BW0TE TTA150BW0UE TTA150BW0WE TTA180BW00F TTA180BW0SF TTA180BW0RF TTA180BW0TF TTA180BW0UF TTA180BW0WF TTA240BW00F TTA240BW0SF TTA240BW0RF TTA240BW0TF TTA240BW0UF TTA240BW0WF R-22, Epoxy Coil R-22, ReliaTel, No LCI Board R-22, ReliaTel, No LCI Board w/Epoxy Coil R-22, ReliaTel, W/LCI Board R-22, ReliaTel, W/LCI Board & Epoxy Coil R-22, Epoxy Coil R-22, ReliaTel, No LCI Board R-22, ReliaTel, No LCI Board w/Epoxy Coil R-22, ReliaTel, W/LCI Board R-22, ReliaTel, W/LCI Board & Epoxy Coil R-22, Epoxy Coil R-22, ReliaTel, No LCI Board R-22, ReliaTel, No LCI Board w/Epoxy Coil R-22, ReliaTel, W/LCI Board R-22, ReliaTel, W/LCI Board & Epoxy Coil R-22, Epoxy Coil R-22, ReliaTel, No LCI Board R-22, ReliaTel, No LCI Board w/Epoxy Coil R-22, ReliaTel, W/LCI Board R-22, ReliaTel, W/LCI Board & Epoxy Coil 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 126,000 126,000 126,000 126,000 126,000 126,000 148,000 148,000 148,000 148,000 148,000 148,000 182,000 182,000 182,000 182,000 182,000 182,000 246,000 246,000 246,000 246,000 246,000 246,000 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 45 45 45 45 45 45 38 38 38 38 38 38 38 38 38 38 38 38 34 34 34 34 34 34 44 44 44 44 44 44 51 51 51 51 51 51 51 51 51 51 51 51 88 88 88 88 88 88 94 94 94 94 94 94
Features:
(TTA120-150B) Climatuff scroll compressors (TTA120-240B) Trane 3-D Scroll compressor Single point power supply Compressor motor overload protection Control transformer High and low pressure cut-out switches Internal pressure relief valve Liquid line filter drier, factory installed UL listed and CSA certified Service valves with pressure taps 5 year compressor warranty Holding charge of Nitrogen (TTA120-180B,C). Copper tube, aluminum plate fin coils Standard compressor warranty for Low ambient cooling to 50F as TTA240B is one year. manufactured, 0 with accessory head pressure control Mounting/lifting rails under base Optional factory installed Black Epoxy Coil for corrossive resistance
SC 17
Power Supply
208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60
Features:
(TTA120-180C) Scroll compressors Single point power supply Compressor motor overload protection Control transformer High and low pressure cut-out switches Internal pressure relief valve Liquid line filter drier, factory installed Service valves with pressure taps Holding charge of Nitrogen Copper tube, aluminum plate fin coils Low ambient cooling to 50F as manufactured, 0 with accessory head pressure control Mounting/lifting rails under base Optional factory installed Black Epoxy Coil for corrossive resistance UL listed and CSA certified 5 year compressor warranty (TTA120-180B,C). Standard compressor warranty for TTA240B is one year.
SC 18
20 Ton TTA240F
Factory Installed Option
Power Supply
208/230-60-3 208/230-60-3 208/230-60-3 208/230-60-3 208/230-60-3 208/230-60-3
R410A, Packed Stock R410A, w/ Epoxy Coil R410A, ReliaTel, No LCI Board R410A, ReliaTel, No LCI Board, w/ Epoxy Coil TTA240F30UA R410A, ReliaTel, w/ LCI Board TTA240F30WA R410A, ReliaTel, w/ LCI Board, w/ Epoxy Coil TTA240F400A TTA240F40SA TTA240F40RA TTA240F40TA R410A, Packed Stock R410A, w/ Epoxy Coil R410A, ReliaTel, No LCI Board R410A, ReliaTel, No LCI Board, w/ Epoxy Coil TTA240F40UA R410A, ReliaTel, w/ LCI Board TTA240F40WA R410A, ReliaTel, w/ LCI Board, w/ Epoxy Coil TTA240FW00A TTA240FW0SA TTA240FW0RA TTA240FW0TA R410A, Packed Stock R410A, w/ Epoxy Coil R410A, ReliaTel, No LCI Board R410A, ReliaTel, No LCI Board, w/ Epoxy Coil TTA240FW0UA R410A, ReliaTel, w/ LCI Board TTA240FW0WA R410A, ReliaTel, w/ LCI Board, w/ Epoxy Coil
94 94 94 94 94 94
44 44 44 44 44 44
45 45 45 45 45 45
94 94 94 94 94 94
44 44 44 44 44 44
45 45 45 45 45 45
Features:
(TTA240F) Scroll compressors Single point power supply Compressor motor overload protection Control transformer High and low pressure cut-out switches Internal pressure relief valve Liquid line filter drier, factory installed Service valves with pressure taps Holding charge of Nitrogen Copper tube, aluminum plate fin coils Low ambient cooling to 50F as manufactured, 0 with accessory head pressure control Mounting/lifting rails under base Optional factory installed Black Epoxy Coil for corrossive resistance UL listed and CSA certified 5 year compressor warranty (TTA240F). Standard compressor warranty for TTA240F is one year.
SC 19
Mfg. Shipping Plant Weight SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR CK/001 CK/001 SPR SPR SPR SPR SPR TY SPR SPR SPR SPR SPR 23 23 23 23 23 23 23 23 23 23 23 23 23 3 3 3 3 14 14 14 1 1 11 23 26 39 39 1 1 10 10 10 10
SC 20
Used With TTA090A_OR,OU,OT,OWTTA240B,F_OR,OU,OT,OW TTA090A_OR,OU,OT,OWTTA240B,F_OR,OU,OT,OW TTA090A_OR,OU,OT,OWTTA240B,F_OR,OU,OT,OW TTA090A_OR,OU,OT,OWTTA240B,F_OR,OU,OT,OW TTA090A_OR,OU,OT,OWTTA240B,F_OR,OU,OT,OW TTA090A_OR,OU,OT,OWTTA240B,F_OR,OU,OT,OW TTA090A_OR,OU,OT,OWTTA240B,F_OR,OU,OT,OW TTA090A_OR,OU,OT,OWTTA240B,F_OR,OU,OT,OW TTA090A-TTA240B,F TTA090A-TTA240B,F
CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001
1 1 1 1 1 1 1 1 1 1
1 2 3 4 5 6
Condensing unit must be on same level as or below Air Handler. Contact Application Engineer, Clarksville before using any other configuration. Some field modification required (see kit installer guide). Qty 2 required on TTA180,240B;TTA180C Do not use with programmable thermostats Kits mount internal to the outdoor unit and operate by sensing liquid line temperatures. Option is compatible for units with ReliaTel controls. Head Pressure Controller only available with ReliaTel option (Digit 10 = R,T,U,W).
SC 21
Thermostats:
Model Number
TCONT200AN11AA BAY28X182 BAY28X183
Used With
All Cooling/(Gas or Elec) TTA090-120A TTA090-120A, 120-240B, 120-180C BAY28X183 BAY28X182,183 TTA090A-240F TTA090A-120A TTA090A-240F TTA090A-240F TTA090A-240F TTA090A-240F TTA090A-TTA240B TTA090A-TTA120A All Room Thermostats
1 1 BAY28X1842 BAY28X1853
4 BAYBASE008A4
BAY28X190
1 Requires Subbase. 2 Requires BAY24X042 relay kit when used with electric heat. 3 Specifically designed for electric heat applications (instant on fan). 4 Option is compatible for units with ReliaTel controls.
SC 22
Accessories:
Model Number Extended Warranties Controls AY28X084 TAYASCT501A1 BAYLEGS002 BAYLEGS003 BAYECMT001 BAYVDTA004 BAYISLT101 Description (See Extended Warranty Section) (See Control Section) Evaporator Defrost Control Kit Anti-Short Cycle Timer Snow Legs - Base and Cap 4" High 4" Extension Extreme Conditions Mounting Kit Vertical Discharge Air Kit Base 4 Rubber Isolators Used With Mfg. Plant Shipping Weight
All Heat Pump Models All Heat Pump Models All Heat Pump Models BAYLEGS002 All Heat Pump Models All Heat Pump Models All Heat Pump Models
TY TY TY TY TY TY TY
1 2 1 1 2 10 1
Two Climatuff compressors Efficiency up to 17.90 SEER and 8.8 HSPF All Aluminum Spine FinTM coil WeatherGuardTM II top shields unit WeatherGuardTM fasteners Quick-SessTM cabinet, service access and refrigerant connections with full coil protection DuraTuffTM base, fast complete drain, weather proof Comfort"R"TM mode approved Glossy corrosion resistant finish Internal compressor high/low pressure & temperature protection Start kit standard 50 or 100% capacity modulation Compressor sump heat Electronic compressor control Liquid line filter/drier Tarpaulin gray cabinet with anthracite gray top
Low sound with advanced fan system and compressor sound insulator Variable speed fan motor Demand defrost control with diagnostics XL Seacoast shield Service valve cover R-22 refrigerant 10 year limited warranty on compressor, coil, and internal functional parts (Residential Use) Extended warranties available S.E.E.T. design testing 100% line run test Low ambient cooling to 55F as shipped Low ambient cooling to 30F with AY28X084
SH 1
Accessories:
Model Number Extended Warranties Controls BAYLEGS002 BAYLEGS003 AY28X084 TAYASCT501A1 BAYKSKT260 BAYECMT001 BAYVDTA003 BAYVDTA004 BAYISLT101 Description (See Extended Warranty Section) (See Control Section) Snow Legs - Base and Cap 4" High 4" Extension Evap. Defrost Control Kit Anti-Short Cycle Timer Start Kit Extreme Conditions Mounting Kit Vertical Discharge Air Kit Base 3 Vertical Discharge Air Kit Base 4 Rubber Isolators Used With Mfg. Plant Shipping Weight
All Heat Pump Models BAYLEGS002 All Heat Pump Models All Heat Pump Models 3 & 4 Ton Models All Heat Pump Models 2 Ton Models 3 - 5 Models All Heat Pump Models
TY TY TY TY TY TY TY TY TY
1 1 1 1 1 2 10 10 1
Climatuff staged scroll compressor Efficiency up to 17.0 SEER and 9.2 HSPF All aluminum Spine FinTM coil WeatherGuardTM II top shields unit WeatherGuardTM fasteners Quick-SessTM cabinet, service access and refrigerant connections with full coil protection DuraTuffTM base, fast complete drain, weather proof Comfort"R"TM mode approved Glossy corrosion resistant finish Internal compressor high/low pressure & temperature protection 024 & 060 ship with start kit Compressor sump heat Liquid line filter-drier Tarpaulin gray cabinet with anthracite gray top
Low sound with advanced fan system and compressor sound insulator Demand Defrost Control with diagnostics High pressure switch XL Seacoast shield Service valve cover R-410A refrigerant 70 or 100% capacity modulation 10 year limited warranty on compressor, coil, and internal functional parts (Residential Use) Extended warranties available S.E.E.T. design testing 100% line run test Low ambient to 30F with AY28X084 Low ambient cooling to 55F as shipped
SH 2
Accessories:
Model Number Extended Warranties Controls BAYLEGS002 BAYLEGS003 AY28X084 TAYASCT501A1 BAYKSKT260 BAYECMT001 BAYVDTA004 BAYISLT101 Description (See Extended Warranty Section) (See Control Section) Snow Legs - Base and Cap 4" High 4" Extension Evap. Defrost Control Kit Anti-Short Cycle Timer Start Kit Extreme Conditions Mounting Kit Vertical Discharge Air Kit Base 4 Rubber Isolators Used With Mfg. Plant Shipping Weight
All Heat Pump Models BAYLEGS002 All Heat Pump Models All Heat Pump Models 2 - 4 Ton Models All Heat Pump Models 2 - 4 Models All Heat Pump Models
TY TY TY TY TY TY TY TY
1 1 1 1 1 2 10 1
Climatuff compressor Efficiency up to 16.50 SEER and 9.0 HSPF All aluminum Spine FinTM coil WeatherGuardTM II top shields unit WeatherGuardTM fasteners Quick-SessTM cabinet, service access and refrigerant connections with full coil protection DuraTuffTM base, fast complete drain, weather proof Comfort"R"TM mode approved Glossy corrosion resistant finish Internal compressor high/low pressure and temperature protection Compressor sump heat Liquid line filter-drier Tarpaulin gray cabinet with anthracite gray top
Low sound with advanced fan system and compressor sound insulator Demand Defrost Control with diagnostics XL Seacoast shield Service valve cover R-22 refrigerant 10 year limited warranty on compressor, coil, and internal functional parts (Residential Use) Extended warranties available S.E.E.T. design testing 100% line run test Low ambient cooling to 55F as shipped Low ambient cooling to 30F with AY28X084
SH 3
Accessories:
Model Number Extended Warranties Controls BAYLEGS002 BAYLEGS003 AY28X084 TAYASCT501A1 BAYKSKT260 BAYECMT001 BAYVDTA003 BAYVDTA004 BAYISLT101 Description (See Extended Warranty Section) (See Control Section) Snow Legs - Base and Cap 4" High 4" Extention Evap. Defrost Control Kit Anti-Short Cycle Timer Start Kit Extreme Conditions Mounting Kit Vertical Discharge Air Kit Base 3 Vertical Discharge Air Kit Base 4 Rubber Isolators Used With Mfg. Plant Shipping Weight
All Heat Pump Models BAYLEGS002 All Heat Pump Models All Heat Pump Models 2.5 - 4 Ton Models All Heat Pump Models 2 - 3 Ton Models 3.5 - 5 Models All Heat Pump Models
TY TY TY TY TY TY TY TY TY
1 1 1 1 1 2 10 10 1
Climatuff compressor Efficiency up to 15.00 SEER and 9.0 HSPF All aluminum Spine FinTM coil WeatherGuardTM II top shields unit WeatherGuardTM fasteners Quick-SessTM cabinet, service access and refrigerant connections with full coil protection DuraTuffTM base, fast complete drain, weather proof Comfort"R"TM mode approved Glossy corrosion resistant finish Internal compressor pressure/ temperature protection Compressor sump heat Liquid line filter-drier Tarpaulin gray cabinet with anthracite gray top
Low sound with advanced fan system and compressor sound insulator XL Seacoast shield Demand Defrost Control with diagnostics 018,024,060 ship with start kit Service valve cover R-22 refrigerant 10 year limited warranty on compressor, coil, and internal functional parts (Residential Use) Extended warranties available S.E.E.T. design testing 100% line run test Low ambient cooling to 55F as shipped Low ambient cooling to 30F with AY28X084
SH 4
Accessories:
Model Number Extended Warranties Controls BAYLEGS002 BAYLEGS003 AY28X084 TAYASCT501A1 BAYKSKT260 BAYECMT001 BAYVDTA003 BAYVDTA004 BAYISLT101 Description (See Extended Warranty Section) (See Control Section) Snow Legs - Base and Cap 4" High 4" Extention Evap. Defrost Control Kit Anti-Short Cycle Timer Start Kit Extreme Conditions Mounting Kit Vertical Discharge Air Kit Base 3 Vertical Discharge Air Kit Base 4 Rubber Isolators Used With Mfg. Plant Shipping Weight
All Heat Pump Models BAYLEGS002 All Heat Pump Models All Heat Pump Models 2.5 - 4 Ton Models All Heat Pump Models 2 - 3 Ton Models 3.5 - 5 Models All Heat Pump Models
TY TY TY TY TY TY TY TY TY
1 1 1 1 1 2 10 10 1
Climatuff compressor Efficiency up to 15.00 SEER and 9.0 HSPF All aluminum Spine FinTM coil WeatherGuardTM II top shields unit WeatherGuardTM fasteners Quick-SessTM cabinet, service access and refrigerant connections with full coil protection DuraTuffTM base, fast complete drain, weather proof Comfort"R"TM mode approved Glossy corrosion resistant finish Internal compressor pressure/ temperature protection Compressor sump heat Liquid line filter-drier Tarpaulin gray cabinet with anthracite gray top
Low sound with advanced fan system and compressor sound insulator Demand Defrost Control with diagnostics High pressure switch 024,060 ship with start kit XL Seacoast shield Service valve cover R-410A refrigerant 10 year limited warranty on compressor, coil, and internal functional parts (Residential Use) Extended warranties available S.E.E.T. design testing 100% line run test Low ambient to 30F with AY28X084 Low ambient cooling to 55F as shipped
SH 5
Accessories:
Model Number Extended Warranties Controls BAYLOAM103 BAYLEGS002 BAYLEGS003 AY28X084 TAYASCT501A1 BAYKSKT260 BAYECMT001 BAYSEAC001 BAYISLT101 Description (See Extended Warranty Section) (See Control Section) Low Ambient Kit Snow Legs - Base and Cap 4" High 4" Extension Evap. Defrost Control Kit Anti-Short Cycle Timer Start Kit Extreme Conditions Mounting Kit Seacoast Kit Rubber Isolators Used With Mfg. Plant Shipping Weight
All Heat Pump Models All Heat Pump Models BAYLEGS002 All Heat Pump Models All Heat Pump Models 2.5 - 4 Ton Models All Heat Pump Models All Heat Pump Models All Heat Pump Models
TY TY TY TY TY TY TY TY TY
1 1 1 1 1 1 2 1 1
Climatuff compressor Efficiency up to 14.00 SEER and 9.0 HSPF All aluminum Spine FinTM coil WeatherGuardTM fasteners Quick-SessTM cabinet, easy service access and refrigerant connections with full coil protection DuraTuffTM base, fast complete drain, weather proof Comfort"R"TM mode approved Glossy corrosion resistant finish Internal compressor high/low pressure and temperature protection 018,024,060 ship with start kit Compressor sump heat Liquid line filter-drier
Tarpaulin gray cabinet with anthracite gray badge & cap Demand Defrost Control with diagnostics Service valve cover R-22 refrigerant 10 year limited warranty on compressor, coil, 5 years internal functional parts (Residential Use) Extended warranties available S.E.E.T. design testing 100% line run test Low ambient cooling to 55F as shipped Low ambient cooling to 30F with AY28X084
SH 6
Accessories:
Model Number Extended Warranties Controls BAYLOAM103 BAYLEGS002 BAYLEGS003 AY28X084 TAYASCT501A1 BAYKSKT260 BAYECMT001 BAYSEAC001 BAYISLT101 Description (See Extended Warranty Section) (See Control Section) Low Ambient Kit Snow Legs - Base and Cap 4" High 4" Extension Evap. Defrost Control Kit Anti-Short Cycle Timer Start Kit Extreme Conditions Mounting Kit Seacoast Kit Rubber Isolators Used With Mfg. Plant Shipping Weight
All Heat Pump Models All Heat Pump Models BAYLEGS002 All Heat Pump Models All Heat Pump Models 2.5 - 4 Ton Models All Heat Pump Models All Heat Pump Models All Heat Pump Models
TY TY TY TY TY TY TY TY TY
1 1 1 1 1 1 2 1 1
Climatuff compressor Efficiency up to 14.00 SEER and 9.0 HSPF All aluminum Spine FinTM coil WeatherGuardTM fasteners Quick-SessTM cabinet, easy service access and refrigerant connections with full coil protection DuraTuffTM base, fast complete drain, weather proof Comfort"R"TM mode approved Glossy corrosion resistant finish Internal compressor high/low pressure & temperature protection 024,060 ship with start kit Compressor sump heat Liquid line filter-drier
Tarpaulin gray cabinet with anthracite gray badge & cap High pressure switch Demand Defrost Control with diagnostics Service valve cover R-410A refrigerant 10 year limited warranty on compressor, coil, 5 years internal functional parts (Residential Use) Extended warranties available S.E.E.T. design testing 100% line run test Low ambient to 30F with AY28X084 Low ambient cooling to 55F as shipped
SH 7
Accessories:
Model Number Extended Warranties Controls BAYLOAM103 BAYLEGS002 BAYLEGS003 AY28X084 TAYASCT501A1 BAYECMT001 BAYSEAC001 BAYISLT101 Description (See Extended Warranty Section) (See Control Section) Low Ambient Kit Snow Legs - Base and Cap 4" High 4" Extension Evap. Defrost Control Kit Anti-Short Cycle Timer Extreme Conditions Mounting Kit Seacoast Kit Rubber Isolators Used With Mfg. Plant Shipping Weight
All Heat Pump Models All Heat Pump Models BAYLEGS002 All Heat Pump Models All Heat Pump Models All Heat Pump Models All Heat Pump Models All Heat Pump Models
TY TY TY TY TY TY TY TY
1 1 1 1 1 2 1 1
Climatuff compressor Efficiency up to 14.00 SEER and 8.50 HSPF All aluminum Spine FinTM coil WeatherGuardTM fasteners Quick-SessTM cabinet, service access and refrigerant connections with full coil protection DuraTuffTM base, fast complete drain, weatherproof Comfort"R"TM mode approved Glossy corrosion resistant finish Internal compressor high/low pressure and temperature protection Start Kit standard Compressor sump heat Liquid line filter-drier Tarpaulin gray cabinet with anthracite gray badge & cap
Low pressure switch Demand Defrost Control with diagnostics Service valve cover R-22 refrigerant 10 year limited warranty on compressor, coil, and 5 years on internal functional parts (Residential Use) Extended warranties available S.E.E.T. design testing 100% line run test Low ambient cooling to 55F as shipped Low ambient cooling to 30F with AY28X084 Low ambient cooling to 0F with BAYLOAM103
SH 8
Accessories:
Model Number Extended Warranties Controls BAYLEGS002 BAYLEGS003 BAYSDEN003 BAYSDEN004 AY28X084 TAYASCT501A1 BAYKSKT260 BAYECMT001 BAYCCHT300 BAYSEAC001 BAYLOAM103 BAYISLT101 Description (See Extended Warranty Section) (See Control Section) Snow Legs - Base and Cap 4" High 4" Extension Sound Enclosure Small Scroll Sound Enclosure Large Scroll Evap. Defrost Control Kit Anti-Short Cycle Timer Start Kit Extreme Conditions Mounting Kit Crankcase Heater Kit Seacoast Kit Low Ambient Kit Rubber Isolators Used With Mfg. Plant Shipping Weight
All Heat Pump Models BAYLEGS002 3 - 4 Ton Models 5 Ton Models All Heat Pump Models All Heat Pump Models 3 - 4 Ton Models All Heat Pump Models 1.5 Ton Models All Heat Pump Models All Heat Pump Models All Heat Pump Models
TY TY TY TY TY TY TY TY TY TY TY TY
1 1 8 8 1 1 1 2 1 1 1 1
Climatuff compressor Efficiency up to 14.00 SEER and 8.5 HSPF All aluminum Spine FinTM coil WeatherGuardTM fasteners Quick-SessTM cabinet, service access and refrigerant connections with full coil protection DuraTuffTM base, fast complete drain, weather proof Comfort"R"TM mode approved Glossy corrosion resistant finish Internal compressor high/low pressure & temperature protection 018,024,030 & 060 ship with Start Kit Liquid line filter-drier Tarpaulin gray cabinet with anthracite gray badge & cap Low Pressure Switch
Demand Defrost Control with diagnostics Compressor sump heat High Pressure Switch Service valve cover R-410A refrigerant 10 year limited warranty on compressor, coil, and 5 years on internal functional parts (Residential Use) Extended warranties available S.E.E.T. design testing 100% line run test Low ambient cooling to 55F as shipped Low ambient cooling to 30F with AY28X084 Low ambient cooling to 0F with BAYLOAM103
SH 9
Accessories:
Model Number Extended Warranties Controls BAYLEGS002 BAYLEGS003 BAYSDEN001 BAYSDEN004 AY28X084 TAYASCT501A1 BAYECMT001 BAYSEAC001 BAYLOAM103 BAYISLT101 Description (See Extended Warranty Section) (See Control Section) Snow Legs - Base and Cap 4" High 4" Extension Sound Enclosure 1 Cycle Recip Sound Enclosure Large Scroll Evap. Defrost Control Kit Anti-Short Cycle Timer` Extreme Conditions Mounting Kit Seacoast Kit Low Ambient Kit Rubber Isolators Used With Mfg. Plant Shipping Weight
All Heat Pump Models BAYLEGS002 1.5 - 2.5 Ton Models 5 Ton Models All Heat Pump Models All Heat Pump Models All Heat Pump Models All Heat Pump Models All Heat Pump Models All Heat Pump Models
TY TY TY TY TY TY TY TY TY TY
1 1 8 8 1 1 2 1 1 1
Climatuff compressor Efficiency up to 13.25 SEER and 8.0 HSPF All aluminum Spine FinTM coil WeatherGuardTM fasteners Quick-SessTM cabinet, service access and refrigerant connections with full coil protection DuraTuffTM base, fast complete drain, weather proof Comfort"R"TM mode approved Glossy corrosion resistant finish Internal compressor high/low pressure & temperature protection Start Kit standard Compressor sump heat Liquid line filter-drier Polyslate gray cabinet with anthracite gray badge & cap
Low Pressure Switch Demand Defrost Control with diagnostics R-22 refrigerant 5 year limited warranty on compressor, coil, and 5 years on internal functional parts (Residential Use) Extended warranties available S.E.E.T. design testing 100% line run test Low ambient cooling to 55F as shipped Low ambient cooling to 30F with AY28X084V Low ambient cooling to 0F with BAYLOAM103
SH 10
Accessories:
Model Number Extended Warranties Controls BAYLEGS002 BAYLEGS003 BAYSDEN003 BAYSDEN004 AY28X084 TAYASCT501A1 BAYKSKT260 BAYECMT001 BAYCCHT300 BAYSEAC001 BAYLOAM103 BAYISLT101 Description (See Extended Warranty Section) (See Control Section) Snow Legs - Base and Cap 4" High 4" Extension Sound Enclosure Small Scroll Sound Enclosure Large Scroll Evap. Defrost Control Kit Anti-Short Cycle Timer Start Kit Extreme Conditions Mounting Kit Crankcase Heater Kit Seacoast Kit Low Ambient Kit Rubber Isolators Used With Mfg. Plant Shipping Weight
All Heat Pump Models BAYLEGS002 3 - 4 Ton Models 5 Ton Models All Heat Pump Models All Heat Pump Models 3 - 4 Ton Models All Heat Pump Models 1.5 Ton Models All Heat Pump Models All Heat Pump Models All Heat Pump Models
TY TY TY TY TY TY TY TY TY TY TY TY
1 1 8 8 1 1 1 2 1 1 1 1
Climatuff compressor Efficiency up to 13.25 SEER and 8.0 HSPF All aluminum Spine FinTM coil WeatherGuardTM fasteners Quick-SessTM cabinet, service access and refrigerant connections with full coil protection DuraTuffTM base, fast complete drain, weather proof Comfort"R"TM mode approved Glossy corrosion resistant finish Internal compressor high/low pressure & temperature protection 018,024,030 & 060 ship with Start Kit Liquid line filter-drier Polyslate gray cabinet with anthracite gray badge & cap Low Pressure Switch
Demand Defrost Control with diagnostics High pressure switch Compressor sump heat R-410A refrigerant 5 year limited warranty on compressor, coil, and 5 years on internal functional parts (Residential Use) Extended warranties available S.E.E.T. design testing 100% line run test Low ambient cooling to 55F as shipped Low ambient cooling to 30F with AY28X084 Low ambient cooling to 0F with BAYLOAM103
SH 11
Accessories:
Model Number Extended Warranties Controls AY28X084 BAY24X045 TAYASCT501A1 BAYLEGS002 BAYLEGS003 BAYSDEN001 BAYSDEN002 BAYSDEN004 BAYECMT001 BAYLOAM103 BAYSEAC001 BAYISLT101 Description (See Extended Warranty Section) (See Control Section) Evaporator Defrost Control ID Fan Delay Kit Anti-Short Cycle Timer Snow Legs - Base and Cap 4" High 4" Extension Sound Enclosure 1 Cycle Recip Sound Enclosure 2 Cycle Recip Sound Enclosure Large Scroll Extreme Conditions Mounting Kit Low Ambient Kit Seacoast Kit Rubber Isolators Used With
All Heat Pump Models All Heat Pump Models All Heat Pump Models All Heat Pump Models BAYLEGS002 2.5 Ton Models 3 - 4 Ton Models 5 Ton Models All Heat Pump Models All Heat Pump Models All Heat Pump Models All Heat Pump Models
TY TY TY TY TY TY TY TY TY TY TY TY
1 1 1 1 1 8 8 8 2 1 1 1
Climatuff compressor All aluminum Spine FinTM coil WeatherGuardTM fasteners Quick-SessTM cabinet, service access and refrigerant connections with full coil protection DuraTuffTM base, fast complete drain, weatherproof Comfort"R"TM mode approved Glosssy corrosion resistant finish Internal compressor high/low pressure & temperature protection Compressor sump heat Liquid line filter-drier Polyslate gray cabinet with anthracite gray badge & cap Low pressure switch Demand Defrost Control with diagnostics
R-22 refrigerant 5 year limited warranty on compressor, coil, and internal functional parts (Residential Use Only) 5 year limited warranty on compressor, coil, and 1 year on parts (Commercial Use Only) Extended warranties available S.E.E.T. design testing 100% line run test Low ambient cooling to 55F as shipped Low ambient cooling to 30F with AY28X084 Low ambient cooling to 0F with BAYLOAM103
SH 12
Accessories:
Model Number Extended Warranties Controls AY28X084 BAY24X045 TAYASCT501A1 BAYLEGS002 BAYLEGS003 BAYSDEN001 BAYSDEN003 BAYSDEN004 BAYECMT001 BAYLOAM103 BAYSEAC001 BAYISLT101 Description (See Extended Warranty Section) (See Control Section) Evaporator Defrost Control ID Fan Delay Kit Anti-Short Cycle Timer Snow Legs - Base and Cap 4" High 4" Extension Sound Enclosure 1 Cycle Recip Sound Enclosure Small Scroll Sound Enclosure Large Scroll Extreme Conditions Mounting Kit Low Ambient Kit Seacoast Kit Rubber Isolators Used With
All Heat Pump Models All Heat Pump Models All Heat Pump Models All Heat Pump Models BAYLEGS002 2.5 Ton Models 3 - 4 Ton Models 5 Ton Models All Heat Pump Models All Heat Pump Models All Heat Pump Models All Heat Pump Models
TY TY TY TY TY TY TY TY TY TY TY TY
1 1 1 1 1 8 8 8 2 1 1 1
Climatuff compressor All aluminum Spine FinTM coil WeatherGuardTM fasteners Quick-SessTM cabinet, service access and refrigerant connections with full coil protection DuraTuffTM base, fast complete drain, weatherproof Comfort"R"TM mode approved Corrosion resistant finish Internal compressor high/low pressure & temperature protection Compressor sump heat Liquid line filter-drier Polyslate gray cabinet with anthracite gray badge & cap Low pressure switch
High pressure switch Demand Defrost Control with diagnostics R-410A refrigerant 5 year limited warranty on compressor, coil, and internal functional parts (Residential Use Only) 5 year limited warranty on compressor, coil, and 1 year on parts (Commercial Use Only) Extended warranties available S.E.E.T. design testing 100% line run test Low ambient cooling to 55F as shipped
Low ambient cooling to 30F with AY28X084 Low ambient cooling to 0F with BAYLOAM103
SH 13
Model Number Description Extended Warranties (See Extended Warranty Section) Controls (See Controls Section) AY28X084 Evaporator Defrost Control BAY24X045 ID Fan Delay Kit TAYASCT501A1 Anti-Short Cycle Timer BAYLEGS002 Snow Legs - Base and Cap 4" High BAYLEGS003 4" Extension BAYECMT001 Extreme Conditions Mounting Kit BAYLOAM103 Low Ambient Kit BAYSEAC001 Seacoast Kit BAYISLT101 Rubber Isolators
Used With
Mfg. Plant
Shipping Weight
All Heat Pump Models All Heat Pump Models All Heat Pump Models All Heat Pump Models BAYLEGS002 All Heat Pump Models All Heat Pump Models All Heat Pump Models All Heat Pump Models
TY TY TY TY TY TY TY TY TY
1 1 1 1 1 2 1 1 1
Climatuff compressor All aluminum Spine FinTM coil WeatherGuardTM fasteners Quick-SessTM cabinet, service access and refrigerant connections with full coil protection DuraTuffTM base, fast complete drain, weatherproof Comfort"R"TM mode approved Glossy corrosion resistant finish Internal compressor high/low pressure & temperature protection Compressor sump heat Liquid line filter-drier Polyslate gray cabinet with anthracite gray badge & cap Demand Defrost Control with diagnostics Low pressure switch
R-22 refrigerant 5 year limited warranty on compressor, coil, and internal functional parts (Residential Use Only) 5 year limited warranty on compressor, coil, and 1 year on parts (Commercial Use Only) Extended warranties available S.E.E.T. design testing 100% line run test Low ambient cooling to 55F as shipped Low ambient cooling to 30F with AY28X084 Low ambient cooling to 0F with BAYLOAM103
SH 14
Mfg. Plant SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR
Shipping Weight 390 390 502 502 390 390 502 502 390 390 502 502
Accessories:
Model Number Description Extended Warranties (1 yr - 5 yr See Extended Warranty Section) BAYISLT005A Rubber-In-Shear Isolator BAYISLT023A Steel Spring Isolator BAYASCT0011 Anti-Short Cycle Timer BAYSTAT033A ODT 45 F to - 10 F BAYGARD024A Coil Guard Kit BAYGARD038A Coil Guard Kit BAYLOAM326A23 Head Pressure Control - 230V* BAYLOAM327A23 Head Pressure Control - 230V* BAYLOAM425A23 Head Pressure Control - 460V* BAYLOAM426A23 Head Pressure Control - 460V* BAYLOAM015A2 Head Pressure Control - 575V* BAYLOAMW22A3 Head Pressure Control - 575V* BAYLOAM429B Head Pressure Control (W/O ReliaTel Option) (W/ElectroMechanical Controls) BAYRLAY005A Heat Pump Interlock Relay Kit
*One head pressure controller per outdoor unit Not required with programmable thermostats. Requires the use of BAYRLAY005A Interlock Relay Kit. Head Pressure Controller only available with ReliaTel option (Digit 10 = R,T,U,W).
Used With
Mfg. Plant
Shipping Weight 2 12 1 1 8 11 23 23 23 23 23 23 23 1
TWA090-120A SPR TWA090-120A SPR TWA090-120A CK/001 TWA090-120A SPR TWA090A SPR TWA120A SPR TWA090A3 SPR TWA120A3 SPR TWA090A4 SPR TWA120A4 SPR TWA090-120AW SPR TWA120AW SPR TTA/TWA090-240 SPR BAYLOAM326-327A,BSPR BAYLOAM425-426A,B
1 2 3
Features:
Trane 3-D Scroll compressor Compressor motor overload protection Control Transformer High and low pressure cut-out switches Liquid line filter drier, factory installed Service valves with pressure taps Thermostatic expansion valve Electronic time and temperature defrost control Solenoid operated switchover valve Holding charge of Nitrogen Copper tube, aluminum plate fin coils Low ambient cooling to 50F as manufactured Low ambient cooling to 0F with accessory head pressure control Heavy gauge steel cabinet Weather resistant baked enamel finish Mounting/lifting rails under base Optional factory installed Black Epoxy Coil for corrosion resistance SH 15 UL listed and CSA certified 5 year compressor warranty
Mfg. Plant SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR
Shipping Weight 816 816 934 934 816 816 934 934 816 816 934 934 Mfg. Plant SPR SPR SPR SPR CK/001 SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR Shipping Weight 2 2 12 12 1 1 22 34 23 23 23 23 23 23 23 1 1
Accessories:
Model Number Description Extended Warranties (1 yr - 5 yr See Extended Warranty Section) BAYISLT009A Rubber-In-Shear Isolators BAYISLT010A Rubber-In-Shear Isolators BAYISLT024A Steel Spring Isolators BAYISLT025A Steel Spring Isolators BAYASCT0012 Anti-Short-Cycle Timer BAYSTAT033A ODT 45F to -10F BAYGARD028A Coil Guard Kit BAYGARD042A Coil Guard Kit BAYLOAM329A134 Head Pressure Control-230V BAYLOAM328A134 Head Pressure Control-230V BAYLOAM428A134 Head Pressure Control-460V BAYLOAM427A134 Head Pressure Control-460V BAYLOAM015A Head Pressure Control-575V* BAYLOAMW22A4 Head Pressure Control-575V* BAYLOAM429B Head Pressure Control (W/ElectroMechanical Controls) BAYRLAY0022 Time delay relay BAYRLAY005A Heat Pump Interlock Kit Used With TWA180B TWA240B TWA180B TWA240B TWA180-240B TWA180-240B TWA180B TWA240B TWA180B3 TWA240B3 TWA180B4 TWA240B4 TWA180BW TWA240BW TTA/TWA090-240
1 Quantity 2 required 1 for each fan. 2 Do not use with programmable thermostats. 3 Requires the use of BAYRLAY005A Interlock Kit. 4 Head Pressure Controller only available with ReliaTel option (Digit 10 = R,T,U,W).
Features:
(2) Trane 3-D Scroll compressors Compressor motor overload protection Control Transformer High and low pressure cut out switches Liquid line filter drier, factory installed Service valves with pressure taps Thermostatic expansion valve Solenoid operated switchover valve
Holding charge of Nitrogen Copper tube, aluminum plate fin coils Electronic time and temperature defrost control Low Ambient cooling to 50F as manufactured Low Ambient cooling to 0F with accessory head pressure control Heavy gauge steel cabinet SH 16
Weather resistant baked enamel finish Mounting/lifting rails under base Optional factory installed Black Epoxy Coil for corrosion resistance UL listed Compressor warranty for TWA180B is five years. Standard compressor warranty for TWA240B is one year. Effective date: January 1, 2007
Shipping Weight 1 2 2 1 1 1 1
1 1 1 2
SH 17
Nomenclature
Accessory Heater
Power Supply
1 = Single Phase 3 = Three Phase
Series/Family
3 = 2 TEH Models only
AH 1
Nomenclature
4 T
2 = R22 4 = R410A
36
00
Application
E = Fully Convertible G = Semi-Convertible V = Vertical F = Front Return
Product Family
E = Leadership-Variable Speed H = High Efficiency C = Replacement/Retail B = Basic
Flow Control
3 = Non-bleed TXV 4 = FCCV*
Feature Identifier
0 = Standard Unit F = Air-Tite
Electrical Connection
0 = Pig Tails B = Circuit Breaker D = Pull Disconnect
Future Option - Factory Installed Heater Nominal KW Value Minor Design Modifications Unit Parts Identifier NOTE: There will be a phase-in of new model numbers for new air handlers over next 2 yrs.
*Shippped with R22 FCCV
AH 2
Nomenclature
T = Business Component W = Weathertron Heat Pump V = Vertical E = Electric Furnace E = Convertible F = Front Return H = Horizontal G = Semi Convertible 0 = Braze Nominal Capacity in 000s of BTUHs P = High Efficiency E = Electronic Variable Speed Drive B = Built-in fan delay C = Convertible All Other = Standard System Electrical Characteristics 2 = Cap Tube 3 = Non Bleed TXV 4 = AccuTron Flow Control/Check Valve 5 = Bleed TXV 0 = Standard F = Airtite Minor Design Change
AH 3
Nomenclature
Product Type TW = Cooling/Heat Pump Air Flow Type E = Convertible - Upflow/Horizontal Only Nominal Gross Cooling Capacity (MBh) 060 = 5 Tons 090 = 7-1/2 Tons 120 = 10 Tons 180 = 15 Tons 240 = 20 Tons Refrigerant Circuits A = Single Circuit B = Dual Circuit Electrical Characteristics 1 = 208-230/1/60 3 = 208-230/3/60 4 = 460/3/60 Factory Installed Options 00 = Packed Stock, No Options Minor Design Sequence Service Digit
AH 4
Air-Tite
Nominal Uncrated Model Power Cap. Clg. Ref. TXV Fan Dimensions(in.) Mfg. Shipping Number Supply (BTUH) Con. Type Speed H W D Plant Weight 2TEE3F62A1000A 200/230/1/60 64,000 BZ Non-Bleed(2) Variable 62.75 26 21 VI 218
2TEE3F Features:
Ships vertical - converts to horizontal by laying on side Six-way convertibility-horizontal left & right, front & rear access; upflow, downflow Electrical knock-outs on either side Compact 21" depth for easy installation Variable speed ECM motor 3.5, 4, and 5 ton models available in 26 widths or with Vortica in 23.5 widths Direct drive blower Comfort-R enhanced dehumidification start-up Soft start - On cycle fan speed is increased gradually to reduce sound and drafts 1" thick foil face insulated cabinet Corrosion resistant galvanized metal with attractive finish Versatile duct flange-allows flush fit 3/4", 1" or 1.5" duct insulation Exclusive duct flange thermal break/seal Expansion valve refrigerant control Check valve for heat pump application Easy Air-Tite access to filter Internally enhanced finned coil tubing External brazed refrigerant connections Filter rack with standard size filter Filter panel stamped with word "filter" Filter door seal 200/230 volt primary & 24 volt secondary transformer Low voltage terminal board Uses 1400 series heaters Access to heater circuit breakers/pull disconnects Polarized plugs for making motor and transformer electrical connections from air handler control box to electric heaters Primary and secondary drain connections Built-in indoor fan delay function for increased efficiency 2TEE3F31A airflow selectable for 1-1/2 3 ton O.D. unit 2TEE3F37A, 39A, 40A airflow selectable for 2 3-1/2 ton O.D. unit 2TEE3F48A, 49A airflow selectable for 3 5 ton O.D. unit 2TEE3F64A, 65A airflow selectable for 3-1/2 5 ton O.D. unit Energy savings continuous fan Enhanced cooling/heating control Five year limited parts warranty Optional extended warranties
AH 5
Air-Tite
Nominal Uncrated Model Power Cap. Clg. Ref. TXV Fan Dimensions(in.) Mfg. Shipping Number Supply (BTUH) Con. Type Speed H W D Plant Weight 4TEE3F62B1000A 200/230/1/60 64,000 BZ Non-Bleed(2) Variable 62.75 26 21 VI 218
4TEE3F Features:
Ships vertical - converts to horizontal by laying on side Six-way convertibility-horizontal left & right, front & rear access; upflow, downflow Electrical knock-outs on either side Compact 21" depth for easy installation Variable speed ECM motor 3.5, 4, and 5 ton models available in 26 widths or with Vortica in 23.5 widths Direct drive blower Comfort-R enhanced dehumidification start-up Soft start - On cycle fan speed is increased gradually to reduce sound and drafts 1" thick foil face insulated cabinet Corrosion resistant galvanized metal with attractive finish Versatile duct flange-allows flush fit 3/4", 1" or 1.5" duct insulation Exclusive duct flange thermal break/seal Expansion valve refrigerant control Check valve for heat pump application Easy Air-Tite access to filter Internally enhanced finned coil tubing External brazed refrigerant connections Filter rack with standard size filter Filter panel stamped with word "filter" Filter door seal 200/230 volt primary & 24 volt secondary transformer Low voltage terminal board Uses 1400 series heaters Access to heater circuit breakers/pull disconnects Polarized plugs for making motor and transformer electrical connections from air handler control box to electric heaters Primary and secondary drain connections Built-in indoor fan delay function for increased efficiency 4TEE3F31B airflow selectable for 1-1/2 3 ton O.D. unit 4TEE3F37B, 39A, 40B airflow selectable for 2 3-1/2 ton O.D. unit 4TEE3F48A, 49B airflow selectable for 3 5 ton O.D. unit 4TEE3F64A, 65B airflow selectable for 3-1/2 5 ton O.D. unit Energy savings continuous fan Enhanced cooling/heating control Five year limited parts warranty Optional extended warranties
AH 6
Accessories:
Model Number Description
Extended Warranties (See Extended Warranty Section) BAYSPEK140B Single Power Entry Kit BAYHTR1415, 1419BRKB TAYPLNM1001 Pedestal Plenum Upflow 2/4TEE3F31,37,39,48,64 TAYPLNM101 Pedestal Plenum Upflow 2/4TEE3F40,49,65 TAYBASE100 Downflow Subbase 2/4TEE3F37,39,48,64 TAYBASE102 Downflow Subbase 2/4TEE3F40,49,65 BAY99X123 Knockout Cover Plate 2/4TEE3F31,37,39,40,48,49,64,65 AY28X084 Evaporator Defrost Control Kit All Heat Pump Models AY28X079 Evaporator Defrost Control Kit All Cooling Models
1 4TEE3F31A-center on plenum for 2" difference in width. 2 Minimum Order 1 unit (1 unit = 50 pcs.)
Model Number
BAYHTR1405000 BAYHTR1405BRK BAYHTR1405PDC BAYHTR1408000 BAYHTR1408BRK BAYHTR1408PDC BAYHTR1410000 BAYHTR1410BRK BAYHTR1410PDC BAYHTR1415BRK BAYHTR1419BRK BAYHTR1425BRK BAYHTR3410000 BAYHTR3415000
240/1/60 BTUH
12,300 12,300 12,300 19,700 19,700 19,700 24,600 24,600 24,600 39,300 49,200 69,300
KW
4.80 4.80 4.80 7.68 7.68 7.68 9.60 9.60 9.60 15.36 19.20 24.96
BTUH
16,400 16,400 16,400 26,200 26,200 26,200 32,800 32,800 32,800 52,400 65,500 85,200
Mfg. Plant
VI VI VI VI VI VI VI VI VI VI VI VI VI VI
Shipping Weight
7 9 9 8 9 9 8 9 9 11 18 18 8 10
208/3/60
7.20 11.53 24,600 39,300 9.60 15.36
240/3/60
32,800 52,400
000 = Pigtails only, BRK = Contains Circuit Breakers, PDC = Contains Pull Disconnect
HEATER MODEL NUMBER BAYHTR---1405 4.80kw 1 700 1000 600 700 900 900 600 1100 800 800 700 1400 900 900 900 1500* 1408 7.68kw 2 700 1000 600 900 900 900 600 1100 800 800 700 1400 900 900 900 1500* 1410 3410 9.60kw 2 700 1000 600 900 900 900 600 1100 800 800 700 1400 900 900 90 0 1500* 3415 15.36kw 3 700 1125 1000 1300 900 1400** 1100 1400 800^ 800^ 1400 1600 900@ 900@ 1200 1800 1419 19.20kw 4 1000 1350 1000 1350 900 1400** 1100 1400 800^ 800^ 1400 1600 900 900 1200 1800 1425 24.96kw 5 N/A N/A N/A N/A N/A N/A 1100 1400 800^^ 800^^ 1400 1600 900 900 1200 1800
2/4TEE3F31
A/C or Elec. Furnace Heat Pump A/C or Elec. Furnace Heat Pump A/C or Elec. Furnace Heat Pump A/C or Elec. Furnace Heat Pump A/C or Elec. Furnace Heat Pump A/C or Elec. Furnace Heat Pump A/C or Elec. Furnace Heat Pump A/C or Elec. Furnace Heat Pump
2/4TEE3F37
2/4TEE3F39
2/4TEE3F40
2/4TEE3F48
2/4TEE3F49
2/4TEE3F64
2/4TEE3F65
*For upflow position only, minimum setting is 1200 ** For horizontal right and downflow only, minimun setting is 1100CFM ^ 208V approved for upflow and horizontal right only ^^ Not qualified for downflow
AH 7
2TFB3F18B, 24B, 30B, 36B Air-Tite 1-1/2 3 Ton Air Handlers Vertical Bottom and Front Return for R-22 Specifications: Vertical Brazed R-22 Air-Tite
Model Number 2TFB3F18B1D05A 2TFB3F18B1D08A 2TFB3F18B1D10A 2TFB3F24B1D05A 2TFB3F24B1D08A 2TFB3F24B1D10A 2TFB3F30B1D05A 2TFB3F30B1D08A 2TFB3F30B1D10A 2TFB3F36B1D05A 2TFB3F36B1D08A 2TFB3F36B1D10A Power Supply 200/230/1/60 200/230/1/60 200/230/1/60 200/230/1/60 200/230/1/60 200/230/1/60 200/230/1/60 200/230/1/60 200/230/1/60 200/230/1/60 200/230/1/60 200/230/1/60 Nominal Cap. Clg. Heater (BTUH) KW* 18,000 5 18,000 8 18,000 10 24,000 5 24,000 8 24,000 10 30,000 5 30,000 8 30,000 10 36,000 5 36,000 8 36,000 10 Ref. Con. BZ BZ BZ BZ BZ BZ BZ BZ BZ BZ BZ BZ TXV Fan Type Speed Non-Bleed 2 Non-Bleed 2 Non-Bleed 2 Non-Bleed 2 Non-Bleed 2 Non-Bleed 2 Non-Bleed 2 Non-Bleed 2 Non-Bleed 2 Non-Bleed 2 Non-Bleed 2 Non-Bleed 2 Uncrated Dimensions(in.) Mfg. Shipping H W D Plant Weight 37 22 19.4 VI 115 37 22 19.4 VI 115 37 22 19.4 VI 115 39 22 19.4 VI 120 39 22 19.4 VI 120 39 22 19.4 VI 120 39 22 19.4 VI 120 39 22 19.4 VI 120 39 22 19.4 VI 120 39 22 19.4 VI 120 39 22 19.4 VI 120 39 22 19.4 VI 120
Accessories:
Model Number Description Extended Warranties (See Extended Warranty Section) AY28X079 Evaporator Defrost Control Kit AY28X084 Evaporator Defrost Control Kit
* Heater KW is based on 240 volt rating.
Features:
Shipped in vertical upflow, bottom return with front access & convertible to vertical upflow front return Air-Tite cabinet - low leakage by design Attractive enamel finish R 4.2-1 insulation Exclusive easy clean coil and drain pan Easy to remove filters and blowers for easy cleaning and replacement Filter rack with throw away filter Easy access electrical controls and hook-up 200/230 volt primary and 24 volt secondary transformer Multi-speed blower Direct drive motor Factory installed electric heaters Factory installed Non-Bleed TXV with mechanical fitting Factory installed service disconnect Internally enhanced finned coil tubing Primary and secondary drain connections Approved for modular or manufactured homes Meets or exceeds Florida's 2% leakage criteria Optional extended warranties Five year limited parts warranty
AH 8
Variable Speed Air-Tite Air Handlers Vertical Bottom and Front Return
Uncrated Dimensions(in.) Mfg. Shipping H W D Plant Weight 39 22 19.4 VI 120 39 22 19.4 VI 120 39 22 19.4 VI 120
Accessories:
Model Number Description Extended Warranties (See Extended Warranty Section) AY28X079 Evaporator Defrost Control Kit AY28X084 Evaporator Defrost Control Kit
* Heater KW is based on 240 volt rating.
Mfg. Plant TY TY
Shipping Weight 1 1
Features:
Shipped in vertical upflow, bottom return with front access & convertible to vertical upflow front return Variable speed ECM motor Enhanced Comfort-R Soft start - cycle-on speed is ramped up gradually to reduce sound and draft Low voltage terminal board Air-Tite cabinet- low leakage by design Attractive enamel finish R 4.2-1 insulation Exclusive easy clean coil and drain pan Easy to remove filters and blowers for easy cleaning and replacement Filter rack with throw away filter Easy access electrical controls and hook-up 200/230 volt primary and 24 volt secondary transformer Factory installed electric heaters Factory installed Non-Bleed TXV with mechanical fitting Factory installed service disconnect Internally enhanced finned coil tubing Primary and secondary drain connections Approved for modular or manufactured homes Meets or exceeds Florida's 2% leakage criteria Optional extended warranties Five year limited parts warranty
AH 9
2TEH3F18 - 60B1000A High Efficiency 1-1/2 5 Ton Air Handlers Convertible and Air-Tite for R-22 Specifications: Horizontal with vertical convertibility R-22 Air-Tite
Accessories:
Model Number Description Used With Extended Warranties (See Extended Warranty Section) BAYSPEK140B Single Power Entry Kit BAYHTR1315BRKB BAYHTR1319BRKB TAYPLNM1001 Pedestal Plenum Upflow 2TEH3F18-60B1000A TAYBASE101 Downflow Subbase 2TEH3F18-36B1000A TAYBASE100 Downflow Subbase 2TEH3F42-60B1000A
BAYHTR1305000 BAYHTR1305BRK BAYHTR1305PDC BAYHTR1308000 BAYHTR1308BRK BAYHTR1308PDC BAYHTR1310000 BAYHTR1310BRK BAYHTR1310PDC BAYHTR1315BRK BAYHTR1319BRK BAYHTR3310000 BAYHTR3315000
000 = Pigtails only, BRK = Contains Circuit Breakers, PDC = Pull Disconnect
Features:
13.0 - 14.0 SEER capability High Efficiency direct drive motor Ships vertical - converts to horizontal by laying on side Six- way convertibility-horizontal (left & right); front & rear access; upflow, downflow Electrical knock-outs on either side Compact 21" depth for easy installation Corrosion resistant galvanized metal with attractive finish Superior condensate performance Enhanced internally finned coil tubes
BA YH TR 13 00 ON LY
Mfg. Plant VI Shipping Weight 5 VI VI VI 10 12 16 Power Supply 240/1/60 KW BTUH
12,300 12,300 12,300 19,700 19,700 19,700 24,600 24,600 24,600 39,300 49,200 24,600 39,300
Nominal Cap. Clg. (BTUH) 18,000 24,000 30,000 36,000 42,000 48,000 60,000
Ref. Con. BZ BZ BZ BZ BZ BZ BZ
Uncrated TXV Fan Dimensions(In.) Mfg. Shipping Type Speed H W D Plant Weight Non-Bleed 4 43 21.5 21 VI 114 Non-Bleed 4 43 21.5 21 VI 121 Non-Bleed 4 45 21.5 21 VI 121 Non-Bleed 4 45 21.5 21 VI 135 Non-Bleed 4 51.8 23.5 21 VI 165 Non-Bleed 4 57.9 23.5 21 VI 188 Non-Bleed 4 57.9 23.5 21 VI 193
KW
BTUH
16,400 16,400 16,400 26,200 26,200 26,200 32,800 32,800 32,800 52,400 65,500 32,800 52,400
Mfg. Plant
VI VI VI VI VI VI VI VI VI VI VI VI VI
Shipping Weight
7 9 9 8 9 9 8 9 9 11 18 8 10
3.60 3.60 3.60 5.76 5.76 5.76 7.20 7.20 7.20 11.53 14.42 7.20 11.53
4.80 4.80 4.80 7.68 7.68 7.68 9.60 9.60 9.60 15.36 19.20 9.60 15.36
208/3/60
240/3/60
Versatile duct flange - allows flush fit 3/4", 1", or 1.5" duct insulation Filter panel stamped with word "filter" 200/230 volt primary & 24 volt secondary transformer Low voltage wire nut connections Insulated cabinet External access to heater circuit breakers Polarized plugs for making electrical connections from air handler control box to heaters Easy Air-Tite access to filter Factory installed non-bleed TXV with mechanical fitting
Direct drive ECM motor Approved for modular or manufactured homes Meets or exceeds Florida's 2% leakage criteria Five year limited parts warranty Optional extended warranties
AH 10
4TEH3F18 - 60B1000A High Efficiency 1-1/2 5 Ton Air Handlers Convertible and Air-Tite for R-410A Specifications: Horizontal with vertical convertibility R-410A Air-Tite
Accessories:
Model Number Description Used With Extended Warranties (See Extended Warranty Section) BAYSPEK140B Single Power Entry Kit BAYHTR1315BRKB BAYHTR1319BRKB TAYPLNM1001 Pedestal Plenum Upflow 4TEH3F18-60B1000A TAYBASE101 Downflow Subbase 4TEH3F18-36B1000A TAYBASE100 Downflow Subbase 4TEH3F42-60B1000A
BAYHTR1305000 BAYHTR1305BRK BAYHTR1305PDC BAYHTR1308000 BAYHTR1308BRK BAYHTR1308PDC BAYHTR1310000 BAYHTR1310BRK BAYHTR1310PDC BAYHTR1315BRK BAYHTR1319BRK BAYHTR3310000 BAYHTR3315000
000 = Pigtails only, BRK = Contains Circuit Breakers, PDC = Pull Disconnect
Features:
13.0 - 14.0 SEER capability High Efficiency direct drive motor Ships vertical - converts to horizontal by laying on side Six- way convertibility-horizontal (left & right); front & rear access; upflow, downflow Electrical knock-outs on either side Compact 21" depth for easy installation Corrosion resistant galvanized metal with attractive finish Superior condensate performance Enhanced internally finned coil tubes
BA YH TR 13 00 ON LY
Mfg. Plant VI Shipping Weight 5 VI VI VI 10 12 16 Power Supply 240/1/60 KW BTUH
12,300 12,300 12,300 19,700 19,700 19,700 24,600 24,600 24,600 39,300 49,200 24,600 39,300
Nominal Cap. Clg. (BTUH) 18,000 24,000 30,000 36,000 42,000 48,000 60,000
Ref. Con. BZ BZ BZ BZ BZ BZ BZ
Uncrated TXV Fan Dimensions(In.) Mfg. Shipping Type Speed H W D Plant Weight Non-Bleed 4 43 21.5 21 VI 114 Non-Bleed 4 43 21.5 21 VI 121 Non-Bleed 4 45 21.5 21 VI 121 Non-Bleed 4 45 21.5 21 VI 135 Non-Bleed 4 51.8 23.5 21 VI 165 Non-Bleed 4 57.9 23.5 21 VI 188 Non-Bleed 4 57.9 23.5 21 VI 193
KW
BTUH
16,400 16,400 16,400 26,200 26,200 26,200 32,800 32,800 32,800 52,400 65,500 32,800 52,400
Mfg. Plant
VI VI VI VI VI VI VI VI VI VI VI VI VI
Shipping Weight
7 9 9 8 9 9 8 9 9 11 18 8 10
3.60 3.60 3.60 5.76 5.76 5.76 7.20 7.20 7.20 11.53 14.42 7.20 11.53
4.80 4.80 4.80 7.68 7.68 7.68 9.60 9.60 9.60 15.36 19.20 9.60 15.36
208/3/60
240/3/60
Versatile duct flange - allows flush fit 3/4", 1", or 1.5" duct insulation Filter panel stamped with word "filter" 200/230 volt primary & 24 volt secondary transformer Low voltage wire nut connections Insulated cabinet External access to heater circuit breakers Polarized plugs for making electrical connections from air handler control box to heaters Easy Air-Tite access to filter Factory installed non-bleed TXV with mechanical fitting
Direct drive ECM motor Approved for modular or manufactured homes Meets or exceeds Florida's 2% leakage criteria Five year limited parts warranty Optional extended warranties
AH 11
Air Handlers Convertible and Air-Tite for R-22 Specifications: Horizontal with vertical convertibility R-22 Air-Tite
Model Number 2TEC3F18B1000A 2TEC3F24B1000A 2TEC3F30B1000A 2TEC3F36B1000A 2TEC3F42B1000A 2TEC3F48B1000A* 2TEC3F55B1000A 2TEC3F60B1000A*
* Two piece cabinet
Power Supply 200/230/1/60 200/230/1/60 200/230/1/60 200/230/1/60 200/230/1/60 200/230/1/60 200/230/1/60 200/230/1/60
Ref. Con. BZ BZ BZ BZ BZ BZ BZ BZ
TXV Fan Type Speed Non-Bleed 3 Non-Bleed 3 Non-Bleed 3 Non-Bleed 3 Non-Bleed 3 Non-Bleed 3 Non-Bleed 3 Non-Bleed 4
Uncrated Dimensions(In.) Mfg. Shipping H W D Plant Weight 43 21.5 21 VI 114 43 21.5 21 VI 121 45 21.5 21 VI 121 45 21.5 21 VI 135 51.8 23.5 21 VI 165 57.9 23.5 21 VI 188 57.9 26.0 21 VI 193 57.9 23.5 21 VI 193
Accessories:
Model Number Description Used With Extended Warranties (See Extended Warranty Section) BAYSPEK140B Single Power Entry Kit BAYHTR1415BRKB, BAYHTR1419BRKB TAYPLNM1001 Pedestal Plenum Upflow 2TEC3F18-60B1000A TAYBASE101 Downflow Subbase 2TEC3F18-36B1000A TAYBASE100 Downflow Subbase 2TEC3F42-60B1000A BAY99X123 Knockout Cover Plate 2TEC3F18-60B1000A Mfg. Plant VI VI VI VI TR Shipping Weight 5 10 12 16
240/1/60 BTUH
12,300 12,300 12,300 19,700 19,700 19,700 24,600 24,600 24,600 39,300 49,200 63,900
KW
4.80 4.80 4.80 7.68 7.68 7.68 9.60 9.60 9.60 15.36 19.20 24.96
BTUH
16,400 16,400 16,400 26,200 26,200 26,200 32,800 32,800 32,800 52,400 65,500 85,200
208/3/60
7.20 11.53 24,600 39,300 9.60 15.36
240/3/60
32,800 52,400
000 = Pigtails only, BRK = Contains Circuit Breakers, PDC = Pull Disconnect
Features:
13.0 SEER Ships in a vertical position convertible for left hand horizontal applications. Six- way convertibility-horizontal (left & right); front & rear access; upflow, downflow Compact 21" depth for easy installation Corrosion resistant galvanized metal with attractive finish Superior condensate performance Enhanced internally finned coil tubes
Five ton model with direct drive ECM motor Versatile duct flange - allows flush fit 3/4", 1", or 1.5" duct insulation Filter panel stamped with word "filter" 200/230 volt primary & 24 volt secondary transformer Low voltage wire nut connections Insulated cabinet External access to heater circuit breakers Polarized plugs for making electrical connections from air handler control box to heaters
Factory installed non-bleed TXV with mechanical fitting Easy Air-Tite access to filter Approved for modular or manufactured homes Meets or exceeds Florida's 2% leakage criteria Five year limited parts warranty Optional extended warranties
AH 12
4TEC3F18 - 60B1000A Air Handlers 1-1/2 5 Ton Convertible and Air-Tite for R-410A Specifications: Horizontal with vertical convertibility R-410A Air-Tite
Model Number 4TEC3F18B1000A 4TEC3F24B1000A 4TEC3F30B1000A 4TEC3F36B1000A 4TEC3F42B1000A 4TEC3F48B1000A* 4TEC3F55B1000A 4TEC3F60B1000A*
* Two piece cabinet
Power Supply 200/230/1/60 200/230/1/60 200/230/1/60 200/230/1/60 200/230/1/60 200/230/1/60 200/230/1/60 200/230/1/60
Nominal Cap. Clg. (BTUH) 18,000 24,000 30,000 36,000 42,000 48,000 58,000 60,000
Ref. Con. BZ BZ BZ BZ BZ BZ BZ BZ
TXV Fan Type Speed Non-Bleed 3 Non-Bleed 3 Non-Bleed 3 Non-Bleed 3 Non-Bleed 3 Non-Bleed 3 Non-Bleed 3 Non-Bleed 4
Uncrated Dimensions(In.) Mfg. Shipping H W D Plant Weight 43 21.5 21 VI 114 43 21.5 21 VI 121 45 21.5 21 VI 121 45 21.5 21 VI 135 51.8 23.5 21 VI 165 57.9 23.5 21 VI 188 57.9 26.0 21 VI 193 57.9 23.5 21 VI 193
Accessories:
Model Number Description Used With Extended Warranties (See Extended Warranty Section) BAYSPEK140B Single Power Entry Kit BAYHTR1415BRKB, BAYHTR1419BRKB TAYPLNM1001 Pedestal Plenum Upflow 4TEC3F18-60B1000A TAYBASE101 Downflow Subbase 4TEC3F18-36B1000A TAYBASE100 Downflow Subbase 4TEC3F42-60B1000A BAY99X123 Knockout Cover Plate 4TEC3F18-60B1000A Mfg. Plant VI VI VI VI TR Shipping Weight 5 10 12 16
240/1/60 BTUH
12,300 12,300 12,300 19,700 19,700 19,700 24,600 24,600 24,600 39,300 49,200 63,900
KW
4.80 4.80 4.80 7.68 7.68 7.68 9.60 9.60 9.60 15.36 19.20 24.96
BTUH
16,400 16,400 16,400 26,200 26,200 26,200 32,800 32,800 32,800 52,400 65,500 85,200
208/3/60
7.20 11.53 24,600 39,300 9.60 15.36
240/3/60
32,800 52,400
000 = Pigtails only, BRK = Contains Circuit Breakers, PDC = Pull Disconnect
Features:
13.0 SEER Ships in a vertical position convertible for left hand horizontal applications. Six- way convertibility-horizontal (left & right); front & rear access; upflow, downflow Compact 21" depth for easy installation Corrosion resistant galvanized metal with attractive finish Enhanced internally finned coil tubes Five ton model with direct drive ECM motor Versatile duct flange - allows flush fit 3/4", 1", or 1.5" duct insulation Filter panel stamped with word "filter" 200/230 volt primary & 24 volt secondary transformer Low voltage wire nut connections Insulated cabinet External access to heater circuit breakers Polarized plugs for making electrical connections from air handler control box to heaters Factory installed non-bleed TXV with mechanical fitting Approved for modular or manufactured homes
AH 13
Air-Tite Air Handlers Vertical Upflow and Horizontal Left for R-22
Uncrated Dimensions(in.) Mfg. Shipping H W D Plant Weight 45.7 18 21 VI 124 45.7 18 21 VI 124 52 18 21 VI 135 52 18 21 VI 135 48.3 23.5 21 VI 147 57.3 23.5 21 VI 172
Accessories:
Model Number Description Used With Extended Warranties (See Extended Warranty Section)
BAYSPEK140B Single Power Entry Kit BAYHTR1415, 1419BRKB
Mfg. Plant
VI
Shipping Weight
5
Heaters:
Power Supply Model Number
BAYHTR1405000 BAYHTR1405BRK BAYHTR1405PDC BAYHTR1408000 BAYHTR1408BRK BAYHTR1408PDC BAYHTR1410000 BAYHTR1410BRK BAYHTR1410PDC BAYHTR1415BRK BAYHTR1419BRK BAYHTR3410000 BAYHTR3415000
208/1/60 KW
3.60 3.60 3.60 5.76 5.76 5.76 7.20 7.20 7.20 11.53 14.42
240/1/60 BTUH
12,300 12,300 12,300 19,700 19,700 19,700 24,600 24,600 24,600 39,300 49,200
KW
4.80 4.80 4.80 7.68 7.68 7.68 9.60 9.60 9.60 15.36 19.20
BTUH
16,400 16,400 16,400 26,200 26,200 26,200 32,800 32,800 32,800 52,400 65,500
208/3/60
7.20 11.53 24,600 39,300 9.60 15.36
240/3/60
32,800 52,400
000 = Pigtails only, BRK = Contains circuit breakers, PDC = C ontains Pull Disconnect
Features:
Exclusive easy to clean coil and drain pan Convertible upflow to horizontal left (no tools required) (matches installed units) Designed to use "off the shelf" standard size replaceable fiberglass filters - Industry Exclusive Easy to remove filters and blowers for easy cleaning and replacement Expanded application fit with narrow cabinet profile Easy access electrical controls and hook-up Attractive enamel finish R 4.2 - 1" insulation Versatile duct flange - allows flush fit with 3/4", 1" or 1.5" duct insulation Air-Tite cabinet - low leak by design IAQ (Indoor Air Quality) sloped/free draining pan (no standing water) Durable, glass-filled composite - Never rust, no leak drain pan Maximum depth 21" - fits pull-down staircase Exclusive maximum width 23.5" - fits 2-ft. wide door all sizes Full line 1 1/2 - 4 tons Direct drive motor Filter panel stamped with word "filter" Expansion valve (non-bleed TXV) with mechanical fitting standard on all models Polarized plugs for easy hook-up to electric heaters Meets or exceeds Florida's 2% leakage criteria 200/230 volt primary and 24 volt secondary transformer Electric heaters with breaker option on all sizes Approved for modular or manufactured homes Five year limited parts warranty Optional extended warranties
AH 14
Mfg. Shipping Plant Weight SPR 298 SPR 388 SPR 439 SPR SPR SPR SPR SPR SPR SPR 298 388 439 298 298 298 439
TWE060A300E 208-230/3/60 60,000 TWE090A300E12 90,000 TWE120A300E12 120,000 TWE060A400E 460/3/60 60,000 60,000 90,000 120,000
Non-Bleed Belt Non-Bleed Belt Non-Bleed Belt Non-Bleed Belt Non-Bleed Belt Non-Bleed Belt Non-Bleed Belt
1 Control Transformer not included. Order Control Transformer accessory when matching these air handlers with 4-6 ton condensing units. 2 Ships connected for 208-230/3/60. Field convertible to 460/3/60.
Specifications: Dual Circuit
Model Number TWE060B100E TWE090B100E TWE120B100E Power Supply 208-230/1/60 208-230/1/60 208-230/1/60 Nom. Cap Cooling TXV (BTUH) Type 60,000 Non-Bleed 90,000 Bleed 120,000 Non-Bleed Drive Belt Belt Belt Uncrated Dimensions (in.) H W D 48 39 23 54 48 26 54 64 26 48 54 54 48 54 39 48 64 39 64 23 26 26 23 26
Mfg. Shipping Plant Weight SPR 298 SPR 388 SPR 473 SPR SPR SPR SPR SPR 298 388 473 298 439
TWE060B300E 208-230/3/60 60,000 TWE090B300E12 90,000 TWE120B300E12 120,000 TWE060B400E 460/3/60 60,000 120,000
Non-Bleed Belt Bleed Belt Non-Bleed Belt Non-Bleed Belt Non-Bleed Belt
TWE120BW00E1 575/3/60
1 Control Transformer not included. Order Control Transformer accessory when matching these air handlers with 4-6 ton condensing units. 2 Ships connected for 208-230/3/60. Field convertible to 460/3/60.
Features:
Low voltage terminal board Expansion valve(s) Check valves for heat pump application Shipped upflow, convertible to horizontal Drain pan Fan relay Evaporator coil 1" Throwaway filters with provisions for field supplied 2" filters Adjustable belt drive motor Evaporator defrost control Refrigerant piping and/or electrical connections provided from either side UL listed and CSA certified Optional extended warranties
AH 15
1 For vertical use only. 2 Discharge Plenum and Grille cannot be used with Electric or Hydronic Heat options. 3 See data catalog for minimum and maximum airflow requirements 4 When Air Handler is in vertical position and close proximity trapping of condensate is required, use of subbase is recommended.
TWE060A, TWE060B TWE090A, TWE090B TWE120A, TWE120B TWE060A, TWE060B TWE090A, TWE090B TWE120A, TWE120B BAYWATR012A, 017C BAYWATR013A, 018C BAYWATR014A, 019C TWE060A, TWE060B TWE090A, TWE090B TWE120A, TWE120B BAYHTRL117A BAYHTRL315A BAYHTRL415A BAYHTRL117A,123A BAYHTRL315A,325A BAYHTRL415A,425A BAYHTRL117A,123A BAYHTRL315A,325A BAYHTRL415A,425A TWE060A, TWE060B TWE090A, TWE090B TWE120A, TWE120B TWE060A, TWE060B TWE090A, TWE090B TWE120A, TWE120B TWE060A1, 060B1 TWE090A1, TWE090B1 TWE060A3,A4,B3,B4 TWE090A3, TWE090B3 TWE120A3, 120B3 TWE060AW TWE090AW TWE120AW
SPR
85
SPR
98
SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR SPR
5 7 10 18 24 28 35 51 32 44 50 35 51 50
AH 16
TWE060-090A, 060-090B TWE120A, TWE120B TWE060A, TWE060B TWE090A, TWE090B TWE120A, TWE120B TWE060A, TWE060B TWE090-120A, 090-120B TWE060A, TWE060B TWE090-120A, 090-120B TWE090-120A3, TWE090-120B3 TWE090-120A3, TWE090-120B3 TWE090AW,TWE120AW,BW TWE120B3 TWE120B3 TWE060,090,120A TWE060,090,120B TWE090A, TWE090B TWE060 TWE090 TWE120
1 2 3 4 5 6 7
Requires use of Subbase accessory. Do not use with units having steam or hot water coil. Do not use if blower will operate at less than 600 RPM Required when 7-1/2-10 ton air handlers are matched with 4-6 ton outdoor units. Required when used with Qty. 2 Split System Condensing Units. When field connected for 460v. Required when used with Qty. 2 Split System Heat Pumps.
AH 17
BAYHTRL410A 460/3/60
9.96
34,013
BAYHTRL415A 460/3/60
14.96
51,088
BAYHTRL425A 460/3/60
24.92
85,102
34.88 5.00
119,115 17,075
BAYHTRLW10A 575/3/60
9.96
34,013
BAYHTRLW15A 575/3/60
14.96
51,088
1 Air Handler with heater of same voltage is single circuit single point. 2 Field converted to 460/3/60.
24.92 34.88
85,102 119,115
No. of Mfg. Stages Used With Plant 1 TWE060-120A1 SPR TWE060-120B1 1 TWE060-120A1 SPR TWE060-120B1 1 TWE060-120A1 SPR TWE060-120B1 2 TWE060-120A1 SPR TWE060-120B1 2 TWE090-120A1 SPR TWE090-120B1 1 TWE060-120A3 SPR TWE060-120B3 1 TWE060-120A3 SPR TWE060-120B3 1 TWE060-120A3 SPR TWE060-120B3 2 TWE060-120A3 SPR TWE060-120B3 2 TWE090-120A3 SPR TWE090-120B3 1 TWE060A4,B4 SPR TWE090-120A3;2 TWE090-120B32 1 TWE060A4,B4 SPR TWE090-120A3;2 TWE090-120B32 1 TWE060A4,B4 SPR TWE090-120A3;2 TWE090-120B32 2 TWE060A4,B4 SPR TWE090-120A3;2 TWE090-120B32 2 TWE090,120A32 SPR TWE090-120B32 1 TWE060AW SPR TWE090-120AW TWE090-120BW 1 TWE060AW SPR TWE090-120AW TWE090-120BW 1 TWE060AW SPR TWE090-120AW TWE090-120BW 2 TWE060-120AW SPR 2 TWE090,120AW SPR
Shipping Weight 37 43 44 48 50 38 38 40 49 33 39
38
41
41
50 39
38
41
41 50
AH 18
Mfg. Shipping Plant Weight SPR 754 SPR 886 SPR SPR SPR SPR Mfg. Plant SPR SPR SPR SPR 754 886 754 886 Shipping Weight 79 82 86 101
Heaters:
Model Power KW Number Supply Rating BAYHTRM310A 208/230/3/60 7.50/ 10.00 BAYHTRM320A 208/230/3/60 14.96/ 19.92 BAYHTRM330A 208/230/3/60 22.50/ 29.92 BAYHTRM350A 208/230/3/60 37.42/ 49.84 BAYHTRM410A BAYHTRM420A BAYHTRM430A BAYHTRM450A 460/3/60 460/3/60 460/3/60 460/3/60 10.00 19.92 29.92 49.84 10.00 19.92 29.92 49.84 Used With TWE180-240B3 TWE180-240B3 TWE180-240B3 TWE180-240B3
79 82 86 100 79 82 86 10
Features:
Low voltage terminal board Expansion valve(s) Check valves for heat pump application Shipped upflow, convertible to horizontal Drain pan Fan relay Evaporator coil 2" throwaway filters Adjustable belt drive motor Evaporator defrost control Refrigerant piping and/or electrical connections provided from either side UL listed and CSA certified
AH 19
15 20 Ton TWE240E
Specifications: Single Circuit
Model Number TWE240E300A TWE240E400A TWE240EW00A Power Supply 208/230-60-3 460/60/3 575/60/3 Nom. Cap Cooling (BTUH) 246,000 246,000 246,000 Refrig. Control R410A-TXV R410A-TXV R410A-TXV Uncrated Dimensions (in.) H W D 72 93 31 72 93 31 72 93 31
Heaters:
Model Power KW Number Supply Rating BAYHTRM310A 208/230/3/60 7.50/ 10.00 BAYHTRM320A 208/230/3/60 14.96/ 19.92 BAYHTRM330A 208/230/3/60 22.50/ 29.92 BAYHTRM350A 208/230/3/60 37.42/ 49.84 BAYHTRM410A 460/3/60 10.00 BAYHTRM420A 460/3/60 19.92 BAYHTRM430A 460/3/60 29.92 BAYHTRM450A 460/3/60 49.84 BAYHTRMW10A 575/3/60 10.00 BAYHTRMW20A 575/3/60 19.92 BAYHTRMW30A 575/3/60 29.92 BAYHTRMW50A 575/3/60 49.84 Nominal No. BTUH Stages 25,598/ 1 34,100 51,058/ 1 67,987 76,793/ 2 102,117 127,714/ 2 170,104 34,100 1 67,987 1 102,117 2 170,104 2 34,100 1 67,987 1 102,117 2 170,104 2 Used With TWE180-240E3 TWE180-240E3 TWE180-240E3 TWE180-240E3 TWE180-240E4 TWE180-240E4 TWE180-240E4 TWE180-240E4 TWE180-240EW TWE180-240EW TWE180-240EW TWE180-240EW Mfg. Shipping Plant Weight FS/200 79 FS/200 FS/200 FS/200 FS/200 FS/200 FS/200 FS/200 FS/200 FS/200 FS/200 FS/200 82 86 101 79 82 86 100 79 82 86 10
Features:
Low voltage terminal board Expansion valve(s) Check valves for heat pump application Shipped upflow, convertible to horizontal Drain pan Fan relay Evaporator coil 2" throwaway filters Adjustable belt drive motor Evaporator defrost control Refrigerant piping and/or electrical connections provided from either side UL listed and CSA certified
AH 20
1 Discharge Plenum and Grille cannot be used with Electric Heat Option, but can be used with hydronic heat options or with no heat. 2 Do not use when using steam or hot water coil option. 3 Requires use of subbase accessory. 4 For vertical use only. 5 See Data Catalog for minimum and maximum airflow requirements.
TWE180B TWE240B,E TWE180B TWE240B,E TWE180B TWE240B,E BAYHTRM330A BAYHTRM430A BAYHTRM330A BAYHTRM430A TWE180B TWE240B,E TWE180B TWE240B,E TWE180B3 TWE240B3,E3,B4,E4 TWE180B4 TWE180BW TWE240BW,EW TWE180-240B,E TWE180B TWE240B,E TWE180-240B,E TWE180B TWE240B,E TWE240B,E TWE180 TWE240
AH 21
Furnace Configuration TU = Upflow / Horizontal TD = Downflow / Horizontal Type D = 80% Premium X = 90% Premium Number of Heating Stages 1 = Single Stage 2 = Two Stage 3 = Three Stage Cabinet Width A = 14.5" Cabinet Width B = 17.5" Cabinet Width C = 21.0" Cabinet Width D = 24.5" Cabinet Width Heating Input 080 = 80,000 BTUH Major Design Change 9 = 115 Volts / Natural Gas F = 115 Volts / Natural Gas with Integrated ifD Filter Airflow Capacity for Cooling 36 = 3 Ton Standard PSC Motor H3 = 3 Ton High Efficiency Motor V3 = 3 Ton Variable Speed Motor Draft Inducer Speeds 1 = Single Speed 2 = Two Speed V = Variable Speed Minor Design Change Service Digit - Not Orderable
FU 1
Type C = Condensing D = Induced Draft E = Electronic Ignition X = Direct Vent Condensing Y = Direct Vent Condensing Variable Speed Heating Input MBTUH 080 = 80,000 BTUH Major Design Change C = Single Stage R = Two Stage All other = Standard System Power Supply & Fuel 115 volt Natural Gas Airflow Capacity for Cooling Example: 36 = 3 Tons 400 CFM/Ton 400 x 3 Tons = 1200 CFM V3 = 1 1/2 - 3 Tons, Variable Speed Motor V4 = 2 - 4 Tons, Variable Speed Motor V5 = 3 - 5 Tons, Variable Speed Motor Minor Design Change V = Variable Speed Inducer Service Digit - Not Orderable
FU 2
Mfg. Shipping Plant Weight TR 119 TR 124 TR 127 TR 132 TR 142 TR 142 TR 151 TR 162 TR 162 TR 186 TR 193
Accessories:
Model Number Description Used WIth
All Cooling/(Gas or Elec) All TUE1/TDE1 Furnaces All TUE1/TDE1 Furnaces All TDE1 Furnaces All TUE1 Upflow 14.5" & 17.5" Furnaces Upflow 21" Furnaces Upflow 24.5" Furnaces All TDE1 Furnaces All TUE1/TDE1 Furnaces
Extended Warranties (See Extended Warranty Section) TCONT200AN11AA Electronic, 1Htg/1Clg (Non Prog.) BAYLPKT210B Propane Conversion Kit BAYLPSS210B1 Propane Conversion Kit BAYFLTR206 Filter Access Door Kit BAYRACK960A2 Filter Rack Kit BAYFLTR317 Filter Accessory Kit BAYFLTR321 Cleanable Filter BAYFLTR324 Cleanable Filter BAYBASE205 Downflow Subbase BAYHALT248 High Alt. Pressure Switch Kit
1 With stainless steel burners. 2 Internal filter rack for side or bottom return air. Includes 17.5" cleanable filter.
Features:
Upflow/Horizontal & Downflow/ Horizontal Power supply 115/1/60 Multi-port In-shot burners Silicon Carbide hot surface igniter with adaptive heat up Heavy gauge, wrap-around steel cabinet Complete front service access Heavy gauge aluminized steel heat exchanger Alternate bottom/left/right return air Slide out blower assembly
Direct drive, 4-speed motors Blower door safety switch Optional L.P. conversion kit Common vent capability Selectable cooling fan off delay option eliminates need for BAY24X045 time delay relay Inner blower door panel on downflow models 3-way vent option on downflow models (top, right, or left)
Non-prorated 20-year heat exchanger limited warranty (Residential use) Optional extended warranties 5 Year limited parts warranty
FU 3
Nominal Cap-BTUH Htg Output 32,000 32,000 47,000 47,000 47,000 64,000 63,000 64,000 64,000 79,000 80,000 79,000 79,000 80,000 96,000 96,000 111,000
ICS* AFUE 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0
Flue Size 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4"
Uncrated Dimensions (in.) H W D 40 14.5 28 40 14.5 28 40 14.5 28 40 14.5 28 40 17.5 28 40 17.5 28 40 17.5 28 40 17.5 28 40 21.0 28 40 17.5 28 40 17.5 28 40 21.0 28 40 21.0 28 40 24.5 28 40 21.0 28 40 24.5 28 40 24.5 28
Mfg. Plant TR TR TR TR TR TR TR TR TR TR TR TR TR TR TR TR TR
Shipping Weight 119 122 124 127 132 139 142 142 154 151 153 162 162 175 176 186 193
Accessories:
Model Number Description Extended Warranties (See Extended Warranty Section) Controls (See Control Section) BAYLPKT210B Propane Conversion Kit BAYLPSS210B1 Propane Conversion Kit BAYHALT248 High Altitude Pressure Switch Kit BAYVENT800B Masonry Chimney Vent Kit BAYRACK960A2 Filter Rack Kit-Internal BAYFLTR200 Side Filter Rack Kit-External BAYFLTR317 Cleanable filter BAYFLTR321 Cleanable filter BAYFLTR324 Cleanable filter Used With Mfg. Shipping Plant Weight
1 With stainless steel burners. 2 Internal filter rack for side or bottom return air. Includes 17.5" cleanable filter
Features:
Power supply 115/1/60 Multi-port In-shot burners Integrated solid state control with self-diagnostics Silicon Nitride hot surface igniter with adaptive heat up Heavy gauge, wrap-around steel cabinet Complete front service access Heavy gauge aluminized steel heat exchanger Alternate bottom/left/right return air Slide out blower assembly Direct drive, 4-speed motors
All XR 80 Furnaces All XR 80 Furnaces TUD1 Furnaces All TUD1A060,080,100,120,140 All TUD1 Furnaces All TUD1 Furnaces 14.5"/17.5" Upflow models 21" Upflow models 24.5" Upflow models
TR TR TR TR TR TR TR TR TR
1 1 2 2 5 5 2 2 2
Blower door safety switch Single wire twinning Hinged blower door Perfect fit door latches Insulated blower door Gasketed blower door Two tone color Quiet slow opening gas valve Optional L.P. conversion kit Common vent capability Selectable cooling fan off delay eliminates need for BAY24X045 time delay relay
Insulated blower compartment Accessory hook-up capability Left/right gas connection 24 volt fuse Manual reset flame roll out switches Non-prorated 20-year heat exchanger limited warranty (Residential use) Optional extended warranties 5 year limited parts warranty
FU 4
Nominal Cap-BTUH Htg Output 31,000 48,000 48,000 48,000 64,000 64,000 80,000 80,000 81,000 96,000 96,000 113,000
ICS* AFUE 78.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0
Flue Size 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4"
Uncrated Dimensions (in.) Mfg. H W D Plant 40 14.5 28 TR 40 14.5 28 TR 40 14.5 28 TR 40 17.5 28 TR 40 17.5 28 TR 40 17.5 28 TR 40 17.5 28 TR 40 21.0 28 TR 40 21.0 28 TR 40 21.0 28 TR 40 24.5 28 TR 40 24.5 28 TR
Shipping Weight 119 129 129 134 146 146 156 166 167 177 189 196
Accessories:
Model Number Controls BAYLPKT210B BAYLPSS210B1 BAYFLTR206 BAYBASE205 BAYHALT248 BAYFLTR206 Description (See Control Section) Propane Conversion Kit Propane Conversion Kit Filter Access Door Kit Downflow Subbase High Altitude Pressure Switch Kit Filter Access Door Kit Used With Mfg. Shipping Plant Weight
Extended Warranties (See Extended Warranty Section)
All XR 80 Furnaces All XR 80 Furnaces All TDD1 Furnaces All TDD1 Furnaces All TDD1 Furnaces All TDD1 Furnaces
TR TR TR TR TR TR
1 1 2 8 2 2
Power supply 115/1/60 Multi-port In-shot burners Integrated solid state control with self-diagnostics Silicon Nitride hot surface igniter with adaptive heat up Heavy gauge, wrap-around steel cabinet Complete front service access Heavy gauge aluminized steel heat exchanger Slide out blower assembly
Direct drive, 4-speed motors Blower door safety switch Optional L.P. conversion kit Common vent Selectable cooling fan off delay eliminates need for BAY24X045 time delay relay Quiet slow opening gas valve Single wire twinning Insulated blower door Insulated blower compartment Accessory hook-up capability
Right and left hand side knockout for venting 24 volt fuse Manual reset flame roll out switches Two tone color Non-prorated 20-year heat exchanger limited warranty (Residential use) Optional extended warranties 5 year limited parts warranty
FU 5
TUD1 - H Upflow/Horizontal
Accessories:
Model Number Description Used With Extended Warranties (1 yr - 5 yr - 10 yr - 15 yr See Extended Warranty Section) Controls (See Control Section) BAYLPKT210B Propane Conversion Kit All XT 80 Furnaces BAYLPSS210B1 Propane Conversion Kit All XT 80 Furnaces BAYHALT248 High Altitude Pressure Switch Kit TUD1 Furnaces BAYVENT800B Masonry Chimney Vent Kit All TUD1A060,080,100,120,140 BAYRACK960A2 Filter Rack Kit - Internal All TUD1 Furnaces BAYFLTR317 Cleanable filter 14.5"/17.5" Upflow models BAYFLTR321 Cleanable filter 21" Upflow models BAYFLTR324 Cleanable filter 24.5" Upflow models Mfg. Shipping Plant Weight
1 With stainless steel burners. 2 Internal filter rack for side or bottom return air. Includes 17.5" cleanable filter
Features:
High efficiency direct drive, 4-speed motor Power supply 115/1/60 Multi-port In-shot burners Integrated solid state control with self-diagnostics Silicon Nitride hot surface igniter with adaptive heat up Heavy gauge, wrap-around steel cabinet Complete front service access Heavy gauge aluminized steel heat exchanger Alternate bottom/left/right return air
TR TR TR TR TR TR TR TR
1 1 2 2 5 2 2 2
Slide out blower assembly Blower door safety switch Single wire twinning Hinged blower door Perfect fit door latches Insulated blower door Gasketed blower door Internal filter rack Standard filter sizes Cleanable high velocity filters Two tone color Quiet slow opening gas valve Optional L.P. conversion kit Common vent capability
Selectable cooling fan off delay eliminates need for BAY24X045 time delay relay Insulated blower compartment Accessory hook-up capability Left/right gas connection 24 volt fuse Manual reset flame roll out switches Non-prorated 20-year heat exchanger limited warranty (Residential use) Optional extended warranties 5 year limited parts warranty
FU 6
TDD1 - H Downflow/Horizontal
Accessories:
Model Number Description Extended Warranties (See Extended Warranty Section) Controls (See Control Section) BAYLPKT210B Propane Conversion Kit BAYLPSS210B1 Propane Conversion Kit BAYFLTR206 Filter Access Door Kit BAYBASE205 Downflow Subbase BAYHALT248 High Altitude Pressure Switch Kit BAYFLTR206 Filter Access Door Kit Used With Mfg. Shipping Plant Weight
All XT 80 Furnaces All XT 80 Furnaces All TDD1 Furnaces All TDD1 Furnaces All TDD1 Furnaces All TDD1 Furnaces
TR TR TR TR TR TR
1 1 2 8 2 2
Power supply 115/1/60 Multi-port In-shot burners Integrated solid state control with self-diagnostics Silicon Nitride hot surface igniter with adaptive heat up Heavy gauge, wrap-around steel cabinet Complete front service access Heavy gauge aluminized steel heat exchanger Slide out blower assembly
High efficiency direct drive 4 speed motor Cleanable high velocity filters Blower door safety switch Optional L.P. conversion kit Common vent Selectable cooling fan off delay eliminates need for BAY24X045 time delay relay Quiet slow opening gas valve Single wire twinning Insulated blower door
Insulated blower compartment Accessory hook-up capability Right and left hand side knockout for venting 24 volt fuse Manual reset flame roll out switches Two tone color Non-prorated 20-year heat exchanger limited warranty (Residential use) Optional extended warranties 5 year limited parts warranty
FU 7
Capacity(000) Output-BTUH Stg 2 Stg 1 32.0 20.8 47.0 31.2 47.0 31.2 63.0 41.6 63.0 41.6 79.0 52.0 79.0 52.0 80.0 52.0 80.0 52.0 95.0 62.4 95.0 62.4 112.0 72.8
ICS* AFUE 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0
Flue Size 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4"
Uncrated Dimensions (in.) H W D 40 14.5 28 40 14.5 28 40 17.5 28 40 17.5 28 40 17.5 28 40 17.5 28 40 21.0 28 40 21.0 28 40 24.5 28 40 21.0 28 40 24.5 28 40 24.5 28
Accessories:
Model Number Description Extended Warranties (See Extended Warranty Section) Controls (See Control Section) BAYLPKT210B Propane Conversion Kit BAYLPSS210B2 Propane Conversion Kit BAYHALT249 High Altitude Pressure Switch Kit BAYVENT800B Masonry Chimney Vent Kit BAYFLTR200 Side Filter Rack Kit-External BAYFLTR317 Cleanable Filter BAYFLTR321 Cleanable Filter BAYFLTR324 Cleanable Filter BAYRACK960A1 Filter Rack Kit Used With Mfg. Shipping Plant Weight
1 Available for models with 1800 CFM or greater which require an additional side return. Includes 17" cleanable filter. 2 With stainless steel burners.
Features:
Upflow/Horizontal Power supply 115/1/60 2-stage gas valve 2-speed venter 2 heating blower speeds Silicon Nitride hot surface igniter with adaptive heat up Integrated solid state control with self-diagnostics Single wire twinning Attractive color accents Hinged blower door Perfect fit door latches Insulated blower door Gasketed blower door Two tone color Heavy gauge aluminized steel heat exchanger Multi-port In-shot burners Complete front service access Alternate bottom/left/right return air Slide out blower assembly Direct drive, 4-speed motors Common vent capability Optional L.P conversion kit Left/right gas connection Accessory hook-up capability
All XL 80 Furnaces All XL 80 Furnaces All TUD2 (& later) Furnaces All TUD2 Models All TUD2 (& later) Furnaces 14.5"/17.5" Upflow Models 21" Upflow Models 24.5" Upflow Models All TUD2 (& later) Furnaces
TR TR TR TR TR TR TR TR TR
1 1 2 2 5 2 2 2 5
Selectable cooling fan off eliminates need for BAY24X045 time delay relay 24 volt fuse Manual reset flame roll out switches Non-prorated 20-year heat exchanger limited warranty (Residential use) Optional extended warranties 5 year limited parts warranty
FU 8
Capacity(000) Output-BTUH Stg 2 Stg 1 32.0 20.8 47.0 31.2 48.0 31.2 64.0 41.6 79.0 52.0 79.0 52.0 79.0 52.0 94.0 62.4 112.0 72.8
ICS* AFUE 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0
Flue Size 4" 4" 4" 4" 4" 4" 4" 4" 4"
Uncrated Dimensions (in.) H W D 40 14.5 28 40 14.5 28 40 17.5 28 40 17.5 28 40 17.5 28 40 21.0 28 40 21.0 28 40 24.5 28 40 24.5 28
Accessories:
Model Number Description Extended Warranties (See Extended Warranty Section) Controls (See Control Section) BAYLPKT210B Propane Conversion Kit BAYLPSS210B1 Propane Conversion Kit BAYFLTR206 Filter Access Door Kit BAYFLTR317 Cleanable Filter BAYFLTR321 Cleanable Filter BAYFLTR324 Cleanable Filter BAYBASE205 Downflow Subbase BAYHALT239 High Alt. Pressure Switch Kit Used With Mfg. Shipping Plant Weight
All XL 80 Furnaces All XL 80 Furnaces All TDD2 Furnaces 14.5"/17.5" Upflow Models 21" Upflow Models 24.5" Upflow Models All XL 80 Furnaces All TDD2 Furnaces
TR TR TR TR TR TR TR TR
1 1 2 2 2 2 8 2
Power supply 115/1/60 2-stage gas valve 2-speed venter Heavy gauge aluminized steel heat exchanger Multi-port In-shot burners Complete front service access Alternate bottom/left/right return air Slide out blower assembly Direct drive, 4-speed motors Optional L.P conversion kit Left/right gas connection Silicon Nitride hot surface igniter with adaptive heat up
Common vent capability Single wire twinning Accessory hook-up capability Convertible to horizontal Inner blower door panel Integrated solid state control with self-diagnostics Selectable cooling fan off delay eliminates need for BAY24X045 time delay relay Insulated blower door Right-hand side knockout for venting 24 volt fuse Manual reset flame roll out switches
Non-prorated 20-year heat exchanger limited warranty (Residential use) Optional extended warranties 1 year limited warranty on parts
FU 9
ICS* AFUE
80.0 80.0 80.0 80.0 80.0 80.0 80.0
Shipping Weight
136 142 166 142 166 193 197
Capacity (000) Output-BTUH Stg 2 Stg 1 48.0 31.2 63.0 41.6 81.0 52.0 95.0 62.4
Mfg. Plant TR TR TR TR
Accessories:
Model Mfg. Shipping Number Description Used With Plant Weight Extended Warranties (See Extended Warranty Section) Controls (See Control Section) BAYLPKT210B Propane Conversion Kit All XV 80 Furnaces TR 1 BAYLPSS210B2 Propane Conversion Kit All XV 80 Furnaces TR 1 BAYFLTR206 Filter Access Door Kit All TDD-R Furnaces TR 2 BAYBASE205 Downflow Subbase All TDD-R XV Furnaces TR 8 BAYHALT249 High Alt. Pressure Switch Kit TUD-R-K/TDD-R-F TR 2 BAYVENT800B Masonry Chimney Vent Kit All TUD060,080,100,120, TR 2 140 R9V Models BAYFLTR200 Side Filter Rack Kit-External All TUD-R-K (& later) Furnaces TR 5 BAYRACK960A1 Filter Rack Kit-Internal All TUD-R9V-K (& later) Furnaces TR 5
1 Available for models with 1800 CFM or greater which require an additional side return. Includes 17" cleanable filter 2 With stainless steel burners.
Features:
Upflow/Horizontal & Downflow/ Horizontal Power supply 115/1/60 2-stage gas valve 2-speed venter Silicon Nitride hot surface igniter with adaptive heat up Integrated solid state control Attractive color accents Heavy gauge aluminized steel heat exchanger Multi-port In-shot burners Complete front service access Alternate bottom/left/right return air Slide out blower assembly Hinged blower door Perfect fit door catches Insulated bower door Gasketed blower door Internal filter rack Standard filter sizes Two tone color Variable speed ECM blower motor TDD models have right and left hand side knockout for venting Integrated solid state control with self-diagnostics Common vent capability Cleanable framed filters Optional L.P. conversion kit
Left/right gas connection Accessory hook-up capability Inner blower door panel TDD models only Selectable cooling fan off delay eliminates need for BAY24X045time delay kit Enhanced cooling control Non-prorated 20-year heat exchanger limited warranty (Residential use) Optional extended warranties 5 year limited parts warranty
FU 10
Accessories:
Model Number Description Extended Warranties (See Extended Warranty Section) CONTROLS See Comfort Controls Section BAYLPKT210B Propane Conversion Kit BAYLPSS210B1 Propane Conversion Kit BAY69X147 Wall Mount Flange-3" BAY69X148 Wall Mount Flange-2" BAYRACK960A2 Filter Rack Kit - Internal BAYFLTR200 Side Filter Rack - External BAYFLTR317 Cleanable Filter BAYFLTR321 Cleanable Filter BAYFLTR324 Cleanable Filter BAYSWT01AHALTA High Altitude Pressure Switch Kit BAYSWT02AHALTA High Altitude Pressure Switch Kit BAYSWT03AHALTA High Altitude Pressure Switch Kit BAYSWT04AHALTA High Altitude Pressure Switch Kit BAYAIR30AVENTA Concentric Vent Kit BAYVENT200B Sidewall Vent Termination Kit BAYMFGH100A Manufactured/Mobile Home Kit
*For heating/cooling thermostats see outdoor sections.
Used With
1 With stainless steel burners. 2 Internal filter rack for side or bottom return air. Includes 17.5" cleanable filter.
Features:
Power supply 115/1/60 Convertible to horizontal left airflow Type 29-4CTM stainless steel secondary heat exchanger Direct drive, 4-speed motors Silicon Carbide igniter with adaptive heat up Accessory hook-up capability- Hum and EAC Quiet induced draft blower Blower door safety switch
TUC1 Furnaces TUC1 Furnaces TUC1 Furnaces TUC1 Furnaces TUC1 Furnaces TUC1 Furnaces Upflow 17.5" Furnaces Upflow 21" Furnaces Upflow 24.5" Furnaces TUC1B040,D100 TUC1B060C TUC1B080C TUC1C100,D120 TUC1 Furnaces All 2 Pipe Direct Vent Furnaces All 2 Pipe Direct Vent Furnaces
TR TR TR TR TR TR TR TR TR TR TR TR TR TR TR TR
1 1 1 1 5 5 2 2 2 2 2 2 2 11 2 2
Dual solenoid combination gas valve & regulator PVC venting - 1 or 2 pipe vent option Left/right gas connection Selectable cooling fan off delay eliminates need for BAY24X045 time delay relay Integrated solid state control with self-diagnostics 24 volt fuse Manual reset burner box limit
20 Year limited primary heat exchanger or secondary heat exchanger warranty to original owner (Residential use) 5 Year limited parts warranty Optional extended warranties
FU 11
Accessories:
Model Number Description Extended Warranties (See Extended Warranty Section) CONTROLS See Comfort Controls Section BAYLPKT210B Propane Conversion Kit BAYLPSS210B1 Propane Conversion Kit BAY69X147 Wall Mount Flange-3" BAY69X148 Wall Mount Flange-2" BAYBASE205 Downflow Subbase BAYFLTR206 Filter Access Door Kit BAYSWT01AHALTA High Altitude Pressure Switch Kit BAYSWT04AHALTA High Altitude Pressure Switch Kit BAYSWT05AHALTA High Altitude Pressure Switch Kit BAYSWT06AHALTA High Altitude Pressure Switch Kit BAYAIR30AVENTA Concentric Vent Kit BAYVENT200B Sidewall Vent Termination Kit BAYMFGH100A Manufactured/Mobile Home Kit Used With Mfg. Shipping Plant Weight
TDC1 Furnaces TDC1 Furnaces TDC1 Furnaces TDC1 Furnaces TDC1 Furnaces TDC1 Furnaces TDC1B040 TDC1B080,D120 TDC1C100 TDC1B060 TDC1 Furnaces All 2 Pipe Direct Vent Furnaces All 2 Pipe Direct Vent Furnaces
TR TR TR TR TR TR TR TR TR TR TR TR TR
1 1 1 1 8 2 2 2 2 2 11 2 2
Convertible to horizontal right airflow Type 29-4CTM stainless steel secondary heat exchanger Inner blower doors Direct drive, 4-speed motors Silicon Carbide igniter with adaptive heat up Accessory hook-up capability- Hum and EAC Quiet induced draft blower Blower door safety switch
Dual solenoid combination gas valve & regulator PVC venting - 1 or 2 pipe vent option Left/right gas connection Selectable cooling fan off delay eliminates need for BAY24X045 time delay relay Integrated solid state control with self-diagnostics 24 volt fuse Manual reset burner box limit
20 Year limited primary heat exchanger or secondary heat exchanger warranty to original owner (Residential use) 5 Year limited parts warranty Optional extended warranties
FU 12
Nominal Cap-BTUH Htg Output 38,000 56,000 74,000 76,000 94,000 93,000 113,000
Uncrated Dimensions (in.) Mfg. H W D Plant 40 17.5 28 TR 40 17.5 28 TR 40 17.5 28 TR 40 21.0 28 TR 40 21.0 28 TR 40 24.5 28 TR 40 24.5 28 TR
Accessories:
Model Number Extended Warranties Controls BAYLPKT210B BAYLPSS210B1 BAY69X147 BAY69X148 BAYRACK960A2 BAYFLTR200 BAYFLTR317 BAYFLTR321 BAYFLTR324 BAYSWT01AHALTA BAYSWT02AHALTA BAYSWT03AHALTA BAYSWT04AHALTA BAYSWT01AMALTB BAYAIR30AVENTA BAYVENT200B BAYMFGH100A Description (See Extended Warranty Section) (See Control Section) Propane Conversion Kit Propane Conversion Kit Wall Mount Flange-3" Wall Mount Flange-2" Filter Rack Kit - Internal Side Filter Rack - External Cleanable Filter Cleanable Filter Cleanable Filter High Altitude Pressure Switch Kit High Altitude Pressure Switch Kit High Altitude Pressure Switch Kit High Altitude Pressure Switch Kit Medium Altitude Conversion Kit Concentric Vent Kit Sidewall Vent Termination Kit Manufactured/Mobile Home Kit Used With Mfg. Shipping Plant Weight
TUX1 Furnaces TUX1 Furnaces TUX1 Furnaces TUX1 Furnaces TUX1 Furnaces TUX1 Furnaces Upflow 17.5" Furnaces Upflow 21" Furnaces Upflow 24.5" Furnaces TUX1B040,D100 TUX1B060C TUX1B080C TUX1C100,D120 TUX1C100,D120 TUX1 Furnaces All 2 Pipe Direct Vent Furnaces All 2 Pipe Direct Vent Furnaces
TR TR TR TR TR TR TR TR TR TR TR TR TR TR TR TR TR
1 1 1 1 5 5 2 2 2 2 2 2 2 2 11 2 2
*For heating/cooling thermostats see outdoor sections. With stainless steel burners. Internal filter rack for side or bottom return air. Includes 17" cleanable filter.
1 2
Features:
Power supply 115/1/60 Convertible to horizontal left Type 29-4CTM stainless steel secondary heat exchanger Direct drive, 4-speed motors Silicon Nitride igniter with adaptive heat up Accessory hook-up capability- Hum and EAC Quiet induced draft blower Blower door safety switch Dual solenoid combination gas valve & regulator PVC venting - 1 or 2 pipe vent option Left/right gas connection Single wire twinning Hinged blower door Perfect fit door latches Insulated blower door Gasketed blower door Two tone color Selectable cooling fan off delay eliminates need for BAY24X045 time delay relay Integrated solid state control with self-diagnostics 24 volt fuse Manual reset burner box limit Lifetime limited primary heat exchanger or secondary heat exchanger warranty to original owner (Residential use) 5 Year limited parts warranty Optional extended warranties
FU 13
Mfg. Plant TR TR TR TR TR
Accessories:
Model Number Extended Warranties Controls BAYLPKT210B BAYLPSS210B1 BAY69X147 BAY69X148 BAYBASE205 BAYFLTR206 BAYSWT01AHALTA BAYSWT04AHALTA BAYSWT05AHALTA BAYSWT06AHALTA BAYSWT01AMALTB BAYAIR30AVENTA BAYVENT200B BAYMFGH100A Description (See Extended Warranty Section) (See Control Section) Propane Conversion Kit Propane Conversion Kit Wall Mount Flange-3" Wall Mount Flange-2" Downflow Subbase Filter Access Door Kit High Altitude Pressure Switch Kit High Altitude Pressure Switch Kit High Altitude Pressure Switch Kit High Altitude Pressure Switch Kit Medium Altitude Conversion Kit Concentric Vent Kit Sidewall Vent Termination Kit Manufactured/Mobile Home Kit Used With Mfg. Shipping Plant Weight
TDX1 Furnaces TDX1 Furnaces TDX1 Furnaces TDX1 Furnaces TDX1 Furnaces TDX1 Furnaces TDX1B040 TDX1B080,D120 TDX1C100 TDX1B060 TDX1C100,D120 TDX1 Furnaces All 2 Pipe Direct Vent Furnaces All 2 Pipe Direct Vent Furnaces
TR TR TR TR TR TR TR TR TR TR TR TR TR TR
1 1 1 1 8 2 2 2 2 2 2 11 2 2
Power supply 115/1/60 Convertible to horizontal left Type 29-4CTM stainless steel secondary heat exchanger Inner blower doors Direct drive, 4-speed motors Silicon Nitride igniter with adaptive heat up Accessory hook-up capability- Hum and EAC Quiet induced draft blower Blower door safety switch
Dual solenoid combination gas valve & regulator PVC venting - 1 or 2 pipe vent option Left/right gas connection Selectable cooling fan off delay eliminates need for BAY24X045 time delay relay Single wire twinning Integrated solid state control with self-diagnostics 24 volt fuse Manual reset burner box limit
Lifetime limited primary heat exchanger or secondary heat exchanger warranty to original owner (Residential use) 5 Year limited parts warranty Optional extended warranties
FU 14
Accessories:
Model Number Extended Warranties Controls BAYLPKT210B BAYLPSS210B1 BAY69X147 BAY69X148 BAYFLTR200 BAYFLTR317 BAYFLTR321 BAYFLTR324 BAYSWT01AHALTA BAYSWT02AHALTA BAYSWT03AHALTA BAYSWT04AHALTA BAYAIR30AVENTA BAYVENT200B BAYMFGH100A Description (See Extended Warranty Section) (See Control Section) Propane Conversion Kit Propane Conversion Kit Wall Mount Flange-3" Wall Mount Flange-2" Side Filter Rack - External Cleanable Filter Cleanable Filter Cleanable Filter High Altitude Pressure Switch Kit High Altitude Pressure Switch Kit High Altitude Pressure Switch Kit High Altitude Pressure Switch Kit Concentric Vent Kit Sidewall Vent Termination Kit Manufactured/Mobile Home Kit Used With Mfg. Shipping Plant Weight
TUX1 Furnaces TUX1 Furnaces TUX1 Furnaces TUX1 Furnaces TUX1 Furnaces Upflow 17.5" Furnaces Upflow 21" Furnaces Upflow 24.5" Furnaces TUX1B040 TUX1B060C TUX1B080C TUX1C100,D120 TUX1 Furnaces All 2 Pipe Direct Vent Furnaces All 2 Pipe Direct Vent Furnaces
TR TR TR TR TR TR TR TR TR TR TR TR TR TR TR
1 1 1 1 5 2 2 2 2 2 2 2 11 2 2
Power supply 115/1/60 Convertible to horizontal left Type 29-4CTM stainless steel secondary heat exchanger Direct drive high efficiency 4-speed motor Silicon Nitride igniter with adaptive heat up Accessory hook-up capability- Hum and EAC Quiet induced draft blower Blower door safety switch Dual solenoid combination gas valve & regulator PVC venting - 1 or 2 pipe vent option Left/right gas connection
Hinged blower door Perfect fit door latches Insulated blower door Gasketed blower door Two tone color Internal filter rack accepts standard filter sizes Cleanable high velocity filters Selectable cooling fan off delay eliminates need for BAY24X045 time delay relay Single wire twinning Integrated solid state control with self-diagnostics 24 volt fuse Manual reset burner box limit
Lifetime limited primary heat exchanger or secondary heat exchanger warranty to original owner (Residential use) 5 year limited parts warranty Optional extended warranties
FU 15
Accessories:
Model Number Extended Warranties Controls BAYLPKT210B BAYLPSS210B1 BAY69X147 BAY69X148 BAYBASE205 BAYFLTR206 BAYSWT01AHALTA BAYSWT04AHALTA BAYSWT05AHALTA BAYSWT06AHALTA BAYAIR30AVENTA BAYVENT200B BAYMFGH100A BAYFLTR317 BAYFLTR321 BAYFLTR324 Description (See Extended Warranty Section) (See Control Section) Propane Conversion Kit Propane Conversion Kit Wall Mount Flange-3" Wall Mount Flange-2" Downflow Subbase Filter Access Door Kit High Altitude Pressure Switch Kit High Altitude Pressure Switch Kit High Altitude Pressure Switch Kit High Altitude Pressure Switch Kit Concentric Vent Kit Sidewall Vent Termination Kit Manufactured/Mobile Home Kit Cleanable Filter Cleanable Filter Cleanable Filter Used With Mfg. Shipping Plant Weight
TDX1 Furnaces TDX1 Furnaces TDX1 Furnaces TDX1 Furnaces TDX1 Furnaces TDX1 Furnaces TDX1B040 TDX1B080,D120 TDX1C100 TDX1B060 TDX1 Furnaces All 2 Pipe Direct Vent Furnaces All 2 Pipe Direct Vent Furnaces Upflow 17.5" Furnaces Upflow 21" Furnaces Upflow 24.5" Furnaces
TR TR TR TR TR TR TR TR TR TR TR TR TR TR TR TR
1 1 1 1 8 2 2 2 2 2 11 2 2 2 2 2
Power supply 115/1/60 Convertible to horizontal left Type 29-4CTM stainless steel secondary heat exchanger Inner blower doors Direct drive high efficiency 4-speed motor Internal filter rack accepts standard filter sizes Cleanable high velocity filters Silicon Nitride igniter with adaptive heat up Accessory hook-up capability- Hum and EAC
Quiet induced draft blower Blower door safety switch Dual solenoid combination gas valve & regulator PVC venting - 1 or 2 pipe vent option Left/right gas connection Selectable cooling fan off delay eliminates need for BAY24X045 time delay relay Single wire twinning Integrated solid state control with self-diagnostics
24 volt fuse Manual reset burner box limit Lifetime limited primary heat exchanger or secondary heat exchanger warranty to original owner (Residential use) 5 Year limited parts warranty Optional extended warranties
FU 16
Capacity (000) Output-BTUH Stg 2 Stg 1 56.0 36.0 73.0 48.0 93.0 60.0 112.0 72.0
Uncrated Dimensions (in.) H W D 2,21/2,3" 40 17.5 28 2,21/2,3" 40 17.5 28 21/2, 3" 40 21.0 28 3" 40 24.5 28 Flue Size
Accessories:
Model Number Extended Warranties Controls BAYLPKT210B BAYLPSS210B2 BAYFLTR200
BAYRACK960A
BAYFLTR203 BAYFLTR204 BAYFLTR205 BAYFLTR317 BAYFLTR321 BAYFLTR324 BAYSWT07AHALTA1 BAYSWT08AHALTA1 BAYSWT09AHALTA1 BAYAIR30AVENTA BAYVENT200B BAYMFGH100A
Description (See Extended Warranty Section) (See Control Section) Propane Conversion Kit Propane Conversion Kit Side Filter Rack - External
Filter Rack Kit-Internal
Used With
1 Optional kit allows 200 ft. max. vent length from 5,000-12,000 feet above sea level. See installer's guide. 2 With stainless steel burners. 3 Internal filter rack for side or bottom return air. Includes 17" cleanable filter.
Features:
Direct Drive - 4 speed PSC Motor Silicon Nitride Igniter with adaptive heat up Variable speed induced draft blower Direct/Non-Direct vent option Fused 24 volt control circuit Manual reset burner safety switches Power supply 115/1/60 Convertible to horizontal on left side 2-stage gas valve PVC venting-1 or 2 pipe option Accessory hook-up capability Integrated solid state control with self-diagnostics Attractive color accents Heavy gauge aluminized steel heat exchanger Single wire twinning Hinged blower door Perfect fit door latches Insulated blower door Gasketed blower door Two tone color Multi-port In-shot burners Complete front service access Left/right gas connection Adjustable fan off times Optional L.P conversion kit Selectable cooling fan off delay eliminates need for BAY24X045 time delay kit
Filter Kit/Horizontal Conversion Filter Kit/Horizontal Conversion Filter Kit/Horizontal Conversion Cleanable Filter Cleanable Filter Cleanable Filter High Altitude Kit High Altitude Kit High Altitude Kit Concentric Vent Kit Sidewall Vent Termination Kit Manufactured/Mobile Home Kit
All XL 90 Furnaces All XL 90 Furnaces All XL 90 Furnaces All XL 90 Furnaces TUX2-060,080 TUX2-100 TUX2-120 Upflow 17.5" Furnaces Upflow 21" Furnaces Upflow 24.5" Furnaces TUX2-060 TUX2-080,100 TUX2-120 TUX2 Furnaces TUX2 Furnaces All 2 Pipe Direct Vent Furnaces
TR TR TR
TR
1 1 5
5
TR TR TR TR TR TR TR TR TR TR TR TR
3 3 3 2 2 2 2 2 2 11 2 2
Lifetime limited primary heat exchanger or secondary heat exchanger warranty to original owner (Residential use) 5 Year limited parts warranty Optional extended warranties
FU 17
Capacity (000) Output-BTUH Stg 2 Stg 1 55.0 36.0 74.0 48.0 93.0 60.0 111.0 72.0
Accessories:
Model Number Extended Warranties Controls BAYLPKT210B BAYLPSS210B2 BAYBASE205 BAYSWT07AHALTA1 BAYSWT08AHALTA1 BAYSWT09AHALTA1 BAYAIR30AVENTA BAYVENT200B BAYMFGH100A BAYFLTR317 BAYFLTR321 BAYFLTR324 Description (See Extended Warranty Section) (See Control Section) Propane Conversion Kit Propane Conversion Kit Downflow Subbase High Altitude Kit High Altitude Kit High Altitude Kit Concentric Vent Kit Sidewall Vent Termination Kit Manufactured/Mobile Home Kit Cleanable Filter Cleanable Filter Cleanable Filter Used With Mfg. Shipping Plant Weight
1 Optional kit allows 200 ft. max. vent length from 5,000-12,000 feet above sea level. See installer's guide. 2 With stainless steel burners.
Features:
Direct drive, 4 speed PSC motor Silicon Nitride Igniter with adaptive heat up Variable speed induced draft blower Direct/Non-Direct vent option Fused 24 volt control circuit Manual reset burner safety switches Power supply 115/1/60 Convertible to horizontal on left side 2-stage gas valve PVC venting-1 or 2 pipe option Accessory hook-up capability Integrated solid state control Attractive color accents Heavy gauge aluminized steel heat exchanger Multi-port In-shot burners Single wire twinning Complete front service access Left/right gas connection Adjustable fan off times Optional L.P conversion kit Selectable cooling fan off delay eliminates need for BAY24X045 time delay kit Lifetime limited primary heat exchanger or secondary heat exchanger warranty to original owner (Residential use) 5 Year limited parts warranty Optional extended warranties
All XL 90 Furnaces All XL 90 Furnaces TDX2 Furnaces TDX2-060 TDX2-080,100 TDX2-120 TDX2 Furnaces TDX2 Furnaces All 2 Pipe Direct Vent Furnaces Upflow 17.5" Furnaces Upflow 21" Furnaces Upflow 24.5" Furnaces
TR TR TR TR TR TR TR TR TR TR TR TR
1 1 8 2 2 2 11 2 2 2 2 2
FU 18
ICS* AFUE
93.0 92.5 93.0 92.5
Flue Size
2,21/2,3" 2,21/2,3" 21/2, 3" 3"
Mfg. Plant
TR TR TR TR
Shipping Weight
156 168 197 206
Accessories:
Model Number Extended Warranties Controls BAYLPKT210B BAYLPSS210B2
BAYRACK960A
BAYFLTR200 BAYFLTR203 BAYFLTR204 BAYFLTR205 BAYFLTR317 BAYFLTR321 BAYFLTR324 BAYSWT07AHALTA1 BAYSWT08AHALTA1 BAYSWT09AHALTA1 BAYAIR30AVENTA BAYVENT200B BAYMFGH100A
1 Optional kit allows 200 ft. max. vent length from 5,000-12,000 feet above sea level. See installer's guide. 2 With stainless steel burners. 3 Internal filter rack for side or bottom return air. Includes 17" cleanable filter.
Features:
Variable speed indoor blower with ECM motor Silicon Nitride Igniter with adaptive heat up Direct/Non-Direct vent option Fused 24 volt control circuit Manual reset burner safety switches Power supply 115/1/60 Convertible to horizontal on left side 2-stage gas valve PVC venting-1 or 2 pipe option Accessory hook-up capability Integrated solid state control with self-diagnostics Attractive color accents Heavy gauge aluminized steel heat exchanger Multi-port In-shot burners Hinged blower door Perfect fit door latches Insulated blower door Gasketed blower door Internal filter rack Standard filter sizes Two tone color Complete front service access Left/right gas connection Adjustable fan off times Cleanable high velocity filters Optional L.P conversion kit Selectable cooling fan off delay eliminates need for BAY24X045 time delay kit Lifetime limited primary heat exchanger or secondary heat exchanger warranty to original owner (Residential use) 5 year limited parts warranty Optional extended warranties
Description Used With (See Extended Warranty Section) (See Control Section) Propane Conversion Kit All XV 90 Furnaces Propane Conversion Kit All XV 90 Furnaces Filter Rack Kit-Internal All XV 90 Furnaces Side Filter Rack - External All XV 90 Furnaces Filter Kit/Horizontal Conversion TUY060,080-R Filter Kit/Horizontal Conversion TUY100-R Filter Kit/Horizontal Conversion TUY120-R Filter Accessory Kit Upflow 14.5" Furnaces Filter Accessory Kit Upflow 21" Furnaces Filter Accessory Kit Upflow 24.5" Furnaces High Altitude Kit TUY060R High Altitude Kit TUY080,100R High Altitude Kit TUY120R Concentric Vent Kit TUY Furnaces Sidewall Vent Termination Kit TUY Furnaces Manufactured/Mobile Home Kit All 2 Pipe Direct Vent Furnaces
TR TR
TR
1 1
5
TR TR TR TR TR TR TR TR TR TR TR TR TR
5 3 3 3 2 2 2 2 2 2 11 2 2
FU 19
Specifications: Downflow/Horizontal Condensing Induced Draft (Sealed Combustion - 1 or 2 Pipe Vent Option)
Capacity (000) Output-BTUH Stg 2 Stg 1 56.0 36.0 74.0 48.0 94.0 60.0 112.0 72.0 ICS* AFUE 92.0 92.5 93.0 92.5 Flue Size 2,21/2,3" 2,21/2,3" 21/2, 3" 3" Uncrated Dimensions (in.) H W D 40 17.5 28 40 17.5 28 40 21.0 28 40 24.5 28 Mfg. Plant TR TR TR TR Shipping Weight 160 168 185 206
Accessories:
Model Number Extended Warranties Controls BAYLPKT210B BAYLPSS210B2 BAYBASE205 BAYSWT07AHALTA1 BAYSWT08AHALTA1 BAYSWT09AHALTA1 BAYAIR30AVENTA BAYVENT200B BAYMFGH100A Description (See Extended Warranty Section) (See Control Section) Propane Conversion Kit Propane Conversion Kit Downflow Subbase High Altitude Kit High Altitude Kit High Altitude Kit Concentric Vent Kit Sidewall Vent Termination Kit Manufactured/Mobile Home Kit Used With Mfg. Shipping Plant Weight
1 Optional kit allows 200 ft. max. vent length from 5,000-12,000 feet above sea level. See installer's guide. 2 With stainless steel burners.
Features:
Variable speed blower with ECM motor Silicon Nitride Igniter with adaptive heat up Direct/Non-Direct vent option Fused 24 volt control circuit Manual reset burner safety switches Power supply 115/1/60 Convertible to horizontal on left side 2-stage gas valve PVC venting-1 or 2 pipe option Accessory hook-up capability Quiet induced draft blower Integrated solid state control Attractive color accents Heavy gauge aluminized steel heat exchanger Multi-port In-shot burners Complete front service access Left/right gas connection Adjustable fan off times Cleanable high velocity filters Optional L.P conversion kit Selectable cooling fan off delay eliminates need for BAY24X045 (time delay kit) Lifetime limited primary heat exchanger or secondary heat exchanger warranty to original owner (Residential use) 5 year limited parts warranty Optional extended warranties
All XV 90 Furnaces All XV 90 Furnaces TDY Furnaces TDY060R TDY080,100R TDY120R TDY Furnaces TDY Furnaces All 2 Pipe Direct Vent Furnaces
TR TR TR TR TR TR TR TR TR
1 1 8 2 2 2 11 2 2
FU 20
2 2 2
BAYSWT09AHALTA BAYSWT01AMALTB
1 Switch 1 Switch
2 2 2
*NOTES: 1) All 2 stage furnace changed from two separate pressure switches to one piggy back switch. 2) This change occurred with the beginning serial number 6151 in April 2006. 3) The high altitude pressure switches are now piggy back type. 4) The new piggy back switches are not interchangeable with the original two switch design. 5) The pressure switch mounting plate is different for the piggy back switches.
FU 21
NOTE: Variable Speed XV80 & XV90 Furnaces should not be twinned and are not approved for twinning applications.
1 Each filter kit contains one (1) high velocity filter. 2 Can not be used with XB80 models, TUD040C-J and TUD040-J or later models. 3 Upflow only. 4 Internal filter rack for side or bottom return air. Includes 17" cleanable filter.
FU 22
Quick Reference
ICS* AFUE
Max. Airflow
Motor H.P.
Outlet Air W D
16.25 16.25 19.75 16.25 19.75 23.25 23.25 13.25 13.25 16.25 16.25 16.25 16.25 19.75 19.75 23.25 19.75 23.25 23.25 13.25 13.25 16.25 16.25 16.25 16.25 23.25 23.25 13.25 13.25 13.25 13.25 13.25 16.25 16.25 16.25 19.75 16.25 16.25 19.75 19.75 23.25 19.75 23.25 23.25 13.25 13.25 13.25 16.25 16.25 16.25 16.25 19.25 19.75 23.25 23.25 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6
1 2
FU 23
Quick Reference
1 2
UPFLOW/HORIZONTAL XV 90 VARIABLE SPEED WITH RECUPERATIVE COIL DIRECT VENT TWO-STAGE TUY060R9V3W 56,000 93.0 1275 Var. Var. 23 BAYLPKT210B 16.25 TUY080R9V3W 73,000 92.5 1400 Var. Var. 23 BAYLPKT210B 16.25 TUY100R9V4W 93,000 93.0 1770 Var. Var. 21/2, 3 BAYLPKT210B 19.75 TUY120R9V5W 112,000 92.5 1920 Var. Var. 3 Only BAYLPKT210B 23.25 UPFLOW/HORIZONTAL XL 90 VARIABLE SPEED WITH RECUPERATIVE COIL NON-DIRECT VENT TWO STAGE 1 OR 2 PIPE TUX2B060A9362A 56,000 93.0 1196 4 1/3 2,21/23 BAYLPKT210B 16.25 TUX2B080A9422A 73,000 92.5 1470 4 1/3 2,21/23 BAYLPKT210B 16.25 1 TUX2C100A9482A 93,000 93.0 1746 4 1/2 2 /23 BAYLPKT210B 19.75 TUX2D120A9602A 112,000 92.5 2261 4 3/4 3 BAYLPKT210B 23.25 UPFLOW/HORIZONTAL XT 90 DIRECT VENT CONDENSING SINGLE STAGE HIGH EFFICIENCY MOTOR TUX1B040A9H21B 38,000 92.1 812 4 1/2 23 BAYLPKT210B 16.25 TUX1B060A9H31B 56,000 92.1 1196 4 1/2 23 BAYLPKT210B 16.25 TUX1B080A9H31B 74,000 92.1 1470 4 1/2 23 BAYLPKT210B 16.25 TUX1C100A9H41B 94,000 92.1 1746 4 3/4 23 BAYLPKT210B 19.75 TUX1D120A9H51B 113,000 92.1 2261 4 1.0 3 Only BAYLPKT210B 23.25 UPFLOW/HORIZONTAL XR 90 WITH RECUPERATIVE COIL DIRECT VENT SINGLE STAGE TUX1B040A9241A 38,000 92.1 812 4 1/5 23 BAYLPKT210B 16.25 TUX1B060A9361A 56,000 92.1 1196 4 1/3 23 BAYLPKT210B 16.25 TUX1B080A9421A 74,000 92.1 1470 4 1/3 23 BAYLPKT210B 16.25 TUX1C080A9601A 76,000 92.1 2121 4 1/2 23 BAYLPKT210B 16.25 TUX1C100A9481A 94,000 92.1 1746 4 1/2 23 BAYLPKT210B 19.75 TUX1D100A9601A 93,000 92.1 2165 4 1/2 23 BAYLPKT210B 23.25 TUX1D120A9601A 113,000 92.1 2261 4 1/2 3 Only BAYLPKT210B 23.25 UPFLOW/HORIZONTAL XB 90 WITH RECUPERATIVE COIL SINGLE STAGE TUC1B040A9241A 37,000 92.1 812 3 1/5 23 BAYLPKT210B 16.25 TUC1B060A9361A 56,000 92.1 1196 4 1/3 23 BAYLPKT210B 16.25 TUC1B080A9421A 74,000 92.1 1470 4 1/3 23 BAYLPKT210B 16.25 TUC1C100A9481A 94,000 92.1 1746 4 1/2 23 BAYLPKT210B 19.75 TUC1D100A9601A 93,000 92.1 2165 4 1/2 23 BAYLPKT210B 23.25 TUC1D120A9601A 113,000 92.1 2261 4 1/2 3 Only BAYLPKT210B 23.25 Isolated Combustion System. Power Supply: 115 Volts, 15 Amps, 20 Amp Fuse, 1/2" Pipe Connections. CFM @ .5" ESP with filter in place.
ICS* AFUE
Max. Airflow
Motor H.P.
Outlet Air W D
19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6
FU 24
Quick Reference
ICS* AFUE
Max. Airflow
Motor H.P.
Downflow Subbase
BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205 BAYBASE205
Outlet Air W
16 16 19.5 23 13 13 16 16 16 19.5 19.5 23 23 13 16 19.5 23 13 13 13 13 16 16 16 19.5 19.5 19.5 23 23 13 16 16 16 19.5 23
D
19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6
Return Air H D
16.25 16.25 19.75 23.25 13.25 13.25 16.25 16.25 16.25 19.75 19.75 23.25 23.25 13.25 16.25 19.75 23.25 13.25 13.25 13.25 13.25 16.25 16.25 16.25 19.75 19.75 19.75 23.25 23.25 13.25 16.25 16.25 16.25 19.75 23.25 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63
1 2
FU 25
Quick Reference
DOWNFLOW/HORIZONTAL XV 90 VARIABLE SPEED WITH RECUPERATIVE COIL DIRECT VENT TWO-STAGE TDY060R9V3W 56,000 92.0 1350 Var. Var. 23 BAYLPKT210B BAYBASE205 16 TDY080R9V3W 74,000 92.5 1210 Var. Var. 23 BAYLPKT210B BAYBASE205 16 TDY100R9V4W 94,000 93.0 1800 Var. Var. 2,21/23 BAYLPKT210B BAYBASE205 19.5 TDY120R9V5W 112,000 92.5 1900 Var. Var. 3 Only BAYLPKT210B BAYBASE205 23 DOWNFLOW/HORIZONTAL XL 90 VARIABLE SPEED WITH RECUPERATIVE COIL NON-DIRECT VENT TWO STAGE ONE OR TWO PIPE TDX2B060A9362A 55,000 92.0 1209 4 1/3 2,21/23 BAYLPKT210B BAYBASE205 16 TDX2B080A9422A 74,000 92.5 1323 4 1/2 2,21/23 BAYLPKT210B BAYBASE205 16 1 TDX2C100A9482A 93,000 93.0 1614 4 1/2 2 /23 BAYLPKT210B BAYBASE205 19.5 TDX2D120A9602A 111,000 92.5 1939 4 3/4 3 BAYLPKT210B BAYBASE205 23 DOWNFLOW/HORIZONTAL XT 90 DIRECT VENT CONDENSING SINGLE STAGE HIGH EFFICIENCY MOTOR TDX1B040A9H31B 38,000 91.0 807 4 1/2 23 BAYLPKT210B BAYBASE205 16 TDX1B060A9H31B 56,000 91.0 1209 4 1/2 23 BAYLPKT210B BAYBASE205 16 TDX1B080A9H31B 74,000 91.0 1323 4 3/4 23 BAYLPKT210B BAYBASE205 16 TDX1C100A9H41B 94,000 91.0 1614 4 3/4 23 BAYLPKT210B BAYBASE205 19.5 TDX1D120A9H51B 112,000 91.0 1939 4 1.0 3 Only BAYLPKT210B BAYBASE205 23 DOWNFLOW/HORIZONTAL XR 90 WITH RECUPERATIVE COIL DIRECT VENT SINGLE STAGE TDX1B040A9241A 38,000 91.0 807 4 1/5 23 BAYLPKT210B BAYBASE205 16 TDX1B060A9361A 56,000 91.0 1209 4 1/3 23 BAYLPKT210B BAYBASE205 16 TDX1B080A9421A 74,000 91.0 1323 3 1/2 23 BAYLPKT210B BAYBASE205 16 TDX1C100A9481A 94,000 91.0 1614 3 1/2 23 BAYLPKT210B BAYBASE205 19.5 TDX1D120A9601A 112,000 91.0 1939 3 1/2 3 Only BAYLPKT210B BAYBASE205 23 DOWNFLOW/HORIZONTAL XB 90 WITH RECUPERATIVE COIL SINGLE STAGE TDC1B040A9241A 38,000 91.0 807 4 1/5 23 BAYLPKT210B BAYBASE205 16 TDC1B060A9361A 56,000 91.0 1082 4 1/3 23 BAYLPKT210B BAYBASE205 16 TDC1B080A9421A 74,000 91.0 1323 3 1/2 23 BAYLPKT210B BAYBASE205 16 TDC1C100A9481A 93,000 91.0 1614 3 1/2 23 BAYLPKT210B BAYBASE205 19.5 TDC1D120A9601A 112,000 91.0 1939 3 1/2 3 Only BAYLPKT210B BAYBASE205 23.0 Isolated Combustion System. CFM @ .5 inches ESP with filter in place.
ICS* AFUE
Max. Airflow
Motor H.P.
Downflow Subbase
Outlet Air W D
19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19 19 19 19 19
Return Air H D
16.25 16.25 19.75 23.25 16.25 16.25 19.75 23.75 16.25 16.25 16.25 19.75 23.25 16.25 16.25 16.25 19.75 23.25 16.25 16.25 16.25 19.75 23.25 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63 19.63
1 2
FU 26
Specifications:
Model Number THV1M087A9V3SA THV1M087A9V5SA TLF1M087A9V3SA TLF1M087A9V5SA TLR1M087A9V3SA TLR1M087A9V5SA TDF1M087A9V3SA TDF1M087A9V5SA
*
THV, TLF, TLR, TDF Vertical Highboy Lowboy Front Flue Lowboy Rear Flue Downflow/Horizontal
Airflow In Tons (Nom.) 3 5 3 5 3 5 3 5 Nominal Cap-BTUH *Htg Output 87,000 87,000 87,000 87,000 87,000 87,000 87,000 87,000 ICS AFUE 82.9 82.6 82.9 82.7 85.0 82.4 84.8 82.6 Flue Size 6" 6" 6" 6" 6" 6" 6" 6"
Uncrated Dimensions(In.) Mfg. Shipping H W D Plant Weight 58.0 22.25 31.0 TR 260 58.0 22.25 31.0 TR 260 41.5 22.25 47.0 TR 300 41.5 22.25 47.0 TR 300p 41.5 22.25 47.0 TR 300 41.5 22.25 47.0 TR 300 22.25 61.25 22.25 TR 280 22.25 61.25 22.25 TR 280
Other input/output capacities are avaliable by changing the burner nozzle. See installer's guide for details.
Accessories:
Model BAYSUB10ABASEA BAYTRM10AVENTA Description Downflow Subbase Top Panel & Trim Ring Used With TDF1M087A9V3, 9V5SAA THV1M087A9V3, 9V5SAA Mfg. Plant TR TR Shipping Weight 22 1
Features:
Up to 85% Annual Fuel Utilization Efficiency (AFUE) 13 gauge hot rolled steel wrap around heat exchanger for durability Beckett Flame Retention Burner operates cleanly and quietly Burner features include primary control with interrupted ignition for reliability, pre-purge and clean cutoff solenoid valve for smooth ignition Burner and controls factory wired Dual clean out ports for quick access and easy cleaning Insulated blower compartment Variable speed blower motor Insulated blower compartment
Slide out blower assembly for quick cleaning and service accessibility Filter rack with cleanable filter (Highboy & Lowboy Models) except Downflow/Horizontal 5 year limited parts warranty Limited lifetime heat exchanger warranty Preformed ceramic fiber combustion chamber for higher efficiencies and more complete combustion 40 VA control transformer for add on cooling Heavy gauge, painted (two tone), steel cabinet
Recessed door handles for easy removal of Highboy & lowboy Furnace doors Lowboy models available with front or rear flue option Highboy models with top or right side venting Downflow/Horizontal model field convertible from Downflow to right or left horizontal 6 Left and Right side fresh air knockouts Highboy and Lowboy Models Barometric draft regulator included
TDF Downflow/Horizontal
THV, TLR, TLF, TDF Vertical Highboy Lowboy Front Flue Lowboy Rear Flue Downflow/Horizontal
Specifications:
Model Number THV1M087A936SA THV1M087A948SA TLF1M087A936SA TLF1M087A948SA TLR1M087A936SA TLR1M087A948SA TDF1M087A936SA TDF1M087A948SA Airflow In Tons (Nom.) 3 4 3 4 3 4 3 4 Nominal Cap-BTUH Htg Output 87,000 87,000 87,000 87,000 87,000 87,000 87,000 87,000 ICS AFUE 82.9 82.6 82.9 82.7 85.0 82.4 84.8 82.6 Flue Size 6" 6" 6" 6" 6" 6" 6" 6"
Uncrated Dimensions(In.) Mfg. Shipping H W D Plant Weight 58.0 22.25 31.0 TR 260 58.0 22.25 31.0 TR 260 41.5 22.25 47.0 TR 300 41.5 22.25 47.0 TR 300 41.5 22.25 47.0 TR 300 41.5 22.25 47.0 TR 300 22.25 61.25 22.25 TR 280 22.25 61.25 22.25 TR 280
Accessories:
Model BAYSUB10ABASEA BAYTRM10AVENTA Description Downflow Subbase Top Panel & Trim Ring Used With TDF1M087A936, 948SAA THV1M087A936, 948SAA Mfg. Plant TR TR Shipping Weight 22 1
Features:
Up to 85% Annual Fuel Utilization Efficiency (AFUE) 13 gauge hot rolled steel wrap around heat exchanger for durability Beckett Flame Retention Burner operates cleanly and quietly Burner features include primary control with interrupted ignition for reliability, valve on delay and clean cutoff solenoid valve for smooth ignition Burner and controls factory wired Dual clean out ports for quick access and easy cleaning Direct drive, permanently lubricated, 4 speed blower motor Insulated blower compartment Slide out blower assembly for quick cleaning and service accessibility Filter rack with cleanable filter (Highboy & Lowboy Models) except Downflow/Horizontal 5 year limited parts warranty Lifetime heat exchanger warranty Preformed ceramic fiber combustion chamber for higher efficiencies and more complete combustion 40 VA control transformer for add on cooling Heavy gauge, powder painted (two tones) steel cabinet Recessed door handles for easy removal of Highboy & lowboy Furnace doors Lowboy models available with front or rear flue option Highboy models with top or right side venting Downflow/Horizontal model field convertible from Downflow to right or left horizontal 6 Left and Right side fresh air knockouts Highboy and Lowboy Models Barometric draft regulator included
TDF Downflow/Horizontal
FU 28
BAYCLE
Specifications:
Model Number BAYCLE14A1422A Coils Cooling or Heat Pump 2/4CXAA018AC3CUA 2/4CXAA024AC3CUA 2/4CXAA018BC3CUA 2/4CXAA024BC3CUA 2/4CXAB025AC3CUA 2/4CXAB031AC3CUA 2/4CXAB036AC3CUA 2/4CXAB042AC3CUA 2/4CXAB048AC3CUA 2/4CXAB025BC3CUA 2/4CXAB031BC3CUA 2/4CXAB036BC3CUA 2/4CXAB042BC3CUA 2/4CXAB048BC3CUA 2/4CXAC037AC3CUA 2/4CXAC043AC3CUA 2/4CXAC049AC3CUA 2/4CXAC060AC3CUA 2/4CXAC037BC3CUA 2/4CXAC043BC3CUA 2/4CXAC049BC3CUA 2/4CXAC060BC3CUA 2/4CXAD050AC3CUA 2/4CXAD061AC3CUA 2/4CXAD050BC3CUA 2/4CXAD061BC3CUA Used With Furnaces Flush on Both Sides 141/2" Wide Furnaces
Coil Enclosures
Coil Enclosure Dimensions Mfg. Shipping H W D Plant Weight 221/2 141/2 211/2 TR 12
BAYCLE17A1722A
TR
14
BAYCLE21A2130A
30
21
211/2
TR
18
BAYCLE24A2430A
30
241/2 211/2
TR
22
Features:
Prepainted steel cabinet
FU 29
FU 30
Coupling/Coil Width (Uncased/Cased) 0 = Braze A = 13/14-1/2 B = 16/17-1/2 C = 19-1/2/21 D = 23/24-1/2 Nominal Capacity in 000s of BTUs Product Family C = Universal S = High Efficiency - Non-Bleed TXV E = High Efficiency - Bleed TXY A = Upflow Only D = Reverse Airflow B = Light Commercial P = Premier Refrigerant Control 3 = Non Bleed TXV 4 = AccuTron TM Flow Control/Check Valve (FCCV) R22 5 = Bleed TXV HP = Heat Pump AC = Cooling only 00 = Cooling only (dual circuit or 10 ton) Minor Design Modifications Unit Parts Identifier
FU 31
U L
Coil Type A A A A A A
IN M
UP LEFT
M U
Uncrated Dimensions(in.) Cased H W D Full 17.5 17.5 21.5 Full 22.5 17.5 21.5 Full 26.88 17.5 21.5 Full 26.88 21.0 21.5 Full 30.0 21.0 21.5 Partial 33.0* 24.5 21.5
ComfortTM coil
2/4TXC-S
FU 32
High Efficiency Comfort Coils Split System Heat Pump/ Cooling Coils
Mfg. Shipping Plant Weight TR 54 TR 67 TR 70 TR 73 TR 90
Specifications: Cased R-22 High Efficiency Coils Upflow/ Downflow/ Horizontal Left
Model Number TXC031S3HPC TXC036S3HPD TXC037S3HPD TXC054S3HPC TXC065S3HPC Nominal Cap.Clg. (BTUH) 30,000 36,000 36,000 54,000 60,000 Coil Type A A A A A TXV Type HP Non-Bleed HP Non-Bleed HP Non-Bleed HP Non-Bleed HP Non-Bleed Cased Full Full Full Full Partial Uncrated Dimensions(in.) H W D 22.5 17.5 21.5 26.9 17.5 21.5 26.9 21.0 21.5 30.0 21.0 21.5 33.0* 24.5 21.5
1 2 - R-22,
TXF Features:
Bi-directional airflow Sloped non corrosive drain pan HP TXV with mechanical fittings Painted cabinet Copper tube and Aluminum fin
ComfortTM coil
TXC-S
FU 33
High Efficiency Comfort Coils R-410A Split System Heat Pump/ Cooling Coils
Mfg. Shipping Plant Weight TR 39 TR 54 TR 67 TR 70 TR 73 TR 77 TR 94
** Overall height. Actual height of case is 30". Downflow application of RXC065 requires field fabrication of case extension shown in the Installer's Guide.
Note: RXC, RXA and RXH series coils include a reducing coupling to accept the smaller interconnecting suction line tubing recommended with R-410A systems.
FU 34 Effective date: January 1, 2007
Features:
Bi-Directional Airflow Same side service access for Horizontal Right or Left applications Eliminates need for field installed Horizontal Drip Tray!!! Fully Convertible - Upflow, Downflow, Left or Right Heat Pump and Cooling Compatible Suction service port 100% foil lined insulation Split inner and outer doors for easy coil cleaning Double sloped non-corrosive drain pan - UL rated 400F Non-Bleed TXV with mechanical fittings Copper tube and Aluminum fin 5 year limited parts warranty on all coils
FURNACE
AIRFLOW
FURNACE
AIRFLOW
FU 35
2 Coils are 3/8" cu/al plate fin. 3 Two circuit cooling coil.
Comfort TM coil
FU 36
Nominal Cap. Clg. (BTUH) 18,000 24,000 24,000 30,000 36,000 37,000 42,000 43,000 48,000 48,000 48,000 60,000 60,000
Coil Type A A A A A A A A A A A A A
TXV Type CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG-Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed
Cased Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Nominal Cap. Clg. (BTUH) 18,000 24,000 24,000 30,000 36,000 37,000 42,000 43,000 48,000 48,000 48,000 60,000 60,000
Coil Type A A A A A A A A A A A A A
TXV Type CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG-Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed
Cased Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Uncrated Dimensions(in.) H W D 17.6 14.5 21.5 22.6 14.5 21.5 17.6 17.5 21.5 17.6 17.5 21.5 22.6 17.5 21.5 22.6 21.0 21.5 22.6 17.5 21.5 22.6 21.0 21.5 26.9 17.5 21.5 26.9 21.0 21.5 26.9 24.5 21.5 30.1 21.0 21.5 30.1 24.5 21.5
Features:
Cased and uncased upflow /downflow cooling only coils Brazed fittings (left side) Drain fitting (left side) Non-Bleed TXV with mechanical fittings. Copper tube with Aluminum fins Painted coil case Suction pressure service port 100% foil lined insulation Split inner and outer doors for easy coil cleaning 5 Year limited parts warranty
Comfort TM coil
FU 37
Nominal Cap. Clg. (BTUH) 18,000 24,000 24,000 30,000 36,000 42,000 48,000 36,000 42,000 48,000 60,000 48,000 60,000
Coil Type A A A A A A A A A A A A A
TXV Type CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed
Cased No No No No No No No No No No No No No
Nominal Cap. Clg. (BTUH) 18,000 24,000 24,000 30,000 36,000 42,000 48,000 36,000 42,000 48,000 60,000 48,000 60,000
Coil Type A A A A A A A A A A A A A
TXV Type CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed
Cased No No No No No No No No No No No No No
Uncrated Dimensions(in.) H W D 15.9 13.3 21.1 17.6 13.3 21.1 15.9 16.3 21.1 15.9 16.3 21.1 21.2 16.3 21.1 21.2 16.3 21.1 25.3 16.3 21.1 20.8 19.8 21.1 20.8 19.8 21.1 24.9 19.8 21.1 29.1 19.8 21.1 25.1 23.3 21.1 28.6 23.3 21.1
Features:
Uncased upflow /downflow cooling only coils Brazed fittings (left side) Drain fitting (left side) Non-Bleed TXV with mechanical fittings. Copper tube with Aluminum fins Suction pressure service port Split inner for easy coil cleaning 5 Year limited parts warranty
FU 38
Features:
Bi-Directional Airflow Same side service access for Horizontal Right or Left applications Eliminates need for field installed Horizontal Drip Tray!!! Fully Convertible - Upflow, Downflow, Left or Right Heat Pump and Cooling Compatible Suction service port 100% foil lined insulation Split inner and outer doors for easy coil cleaning Double sloped non-corrosive drain pan - UL rated 400F Non-Bleed TXV with mechanical fittings Aluminum tube with aluminum fins 5 year limited parts warranty on all coils
IN E L B 7 A 0 L 0 I 2 A V Y L A R A E
FURNACE
AIRFLOW
FURNACE
AIRFLOW
FU 39
IN E L 7 B 0 A 20 IL Y A L V R A A E
Nom. Cap. Cooling Coil TXV (BTUH) Type Type Cased 120,000 Flat CLG-Bleed Full Uncrated Dimensions (in.) H W D 26 25 64 Mfg. Shipping Plant Weight FS 235 100% foil lined insulation Easy case attachment to furnace 3 way application Painted cabinet matches furnace 5 year limited parts warranty
Cased Full Full Full Full Full Full Full Full Full Full Full Full Full
2 Coils are 3/8" cu/al plate fin. 3 Two circuit cooling coil.
Comfort TM coil
FU 40
IN E L 7 B 0 A 20 IL Y A L V R A A E
Nominal Cap. Clg. (BTUH) 18,000 24,000 24,000 30,000 36,000 37,000 42,000 43,000 48,000 48,000 48,000 60,000 60,000 Coil Type A A A A A A A A A A A A A TXV Type CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG-Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed Cased Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Uncrated Dimensions(in.) H W D 17.6 14.5 21.5 22.6 14.5 21.5 17.6 17.5 21.5 17.6 17.5 21.5 22.6 17.5 21.5 22.6 21.0 21.5 22.6 17.5 21.5 22.6 21.0 21.5 26.9 17.5 21.5 26.9 21.0 21.5 26.9 24.5 21.5 30.1 21.0 21.5 30.1 24.5 21.5
Comfort TM coil
Nominal Cap. Clg. (BTUH) 18,000 24,000 24,000 30,000 36,000 37,000 42,000 43,000 48,000 48,000 48,000 60,000 60,000
Coil Type A A A A A A A A A A A A A
TXV Type CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG-Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed
Cased Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Uncrated Dimensions(in.) H W D 17.6 14.5 21.5 22.6 14.5 21.5 17.6 17.5 21.5 17.6 17.5 21.5 22.6 17.5 21.5 22.6 21.0 21.5 22.6 17.5 21.5 22.6 21.0 21.5 26.9 17.5 21.5 26.9 21.0 21.5 26.9 24.5 21.5 30.1 21.0 21.5 30.1 24.5 21.5
Features:
Cased and uncased upflow /downflow cooling only coils Brazed fittings (left side) Drain fitting (left side) Non-Bleed TXV with mechanical fittings. Painted coil case Suction pressure service port 100% foil lined insulation Split inner and outer doors for easy coil cleaning Aluminum tube with aluminum fins 5 Year limited parts warranty
FU 41
IN E L 7 B 0 A 20 IL Y A L V R A A E
Nominal Cap. Clg. (BTUH) 18,000 24,000 24,000 30,000 36,000 42,000 48,000 36,000 42,000 48,000 60,000 48,000 60,000 Coil Type A A A A A A A A A A A A A TXV Type CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed Cased No No No No No No No No No No No No No Uncrated Dimensions(in.) H W D 15.9 13.3 21.1 17.6 13.3 21.1 15.9 16.3 21.1 15.9 16.3 21.1 21.2 16.3 21.1 21.2 16.3 21.1 25.3 16.3 21.1 20.8 19.8 21.1 20.8 19.8 21.1 24.9 19.8 21.1 29.1 19.8 21.1 25.1 23.3 21.1 28.6 23.3 21.1
Nominal Cap. Clg. (BTUH) 18,000 24,000 24,000 30,000 36,000 42,000 48,000 36,000 42,000 48,000 60,000 48,000 60,000
Coil Type A A A A A A A A A A A A A
TXV Type CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed CLG Non-Bleed
Cased No No No No No No No No No No No No No
Uncrated Dimensions(in.) H W D 15.9 13.3 21.1 17.6 13.3 21.1 15.9 16.3 21.1 15.9 16.3 21.1 21.2 16.3 21.1 21.2 16.3 21.1 25.3 16.3 21.1 20.8 19.8 21.1 20.8 19.8 21.1 24.9 19.8 21.1 29.1 19.8 21.1 25.1 23.3 21.1 28.6 23.3 21.1
Features:
Uncased upflow /downflow cooling only coils Brazed fittings (left side) Drain fitting (left side) Non-Bleed TXV with mechanical fittings. Suction pressure service port Split inner for easy coil cleaning Aluminum tube with aluminum fins 5 Year limited parts warranty
FU 42
Features:
3 way Application Cased Cooling Only Brazed fittings Drain fitting Operates as two independent refrigerant systems with one indoor coil and furnace Fits 17.5", 21", 24.5" furnace models Compatible with all outdoor sections - 34 - 74 MBTUH capacities Easy single coil installation Offers application flexibility for special customer requirements Sloped drain pan 5 year limited warranty
Comfort TM coil
FU 43
Accessories:
Model Number BAYTRANS12024 Description 120 to 24 Volt Transformer Used With All TFD Air Cleaners Mfg. Plant VI Shipping Weight 6
Features:
CleanEffects removes up to 99.98% of allergens from the filtered air Removes particles down to .1 microns in size Outperforms HEPA, and up to 100 times more effective than a standard 1" filter Constructed of heavy 18 gage metal to protect the filter and internal electronics Power door provides easy access to internal components and features a filter status display as well as safety interlocks that automatically shut down the power when the door is opened for maintenance or cleaning Designed for flush fit on both sides and rear of equipment cabinet No transitions required on CleanEffects applications Gaskets come with the air cleaner to seal out unwanted air 24 Volt input power 10 year electronics warranty 5 year parts warranty
T F D 145 A L FR 0 0 0 A A
FILTRATION ifD SIZE FURNACE 145 = 14.5" 14D= Downflow 175 = 17.5" 17D= Downflow 210 = 21" 21D= Downflow 245 = 24.5" 24D= Downflow SERVICE SEQUENCE Not Orderable MINOR DESIGN AIR HANDLER 215 = 21.5" 235 = 23.5" 260 = 26" APPLICATION Not Used AH = AIR HANDLER FR = FURNACE POWER SUPPLY L = Low Voltage MAJOR DESIGN SERIES
IC 1
TFD145-260ALUPGRDA TFD14D-24DALUPGRDA
Specifications: Air Handler - 24 Volt Clean Effects Upgrade Kit
Model Number TFD215ALUPGRDA TFD235ALUPGRDA TFD260ALUPGRDA Airflow Range 300-1200 350-1600 400-2000 Perfect Fit Cabinet Width 21-1/2 inch 23-1/2 inch 26 inch Mfg. Plant VI VI VI Shipping Weight 38 40 42
Specifications: Upflow / Side Return Furnace - 24 Volt Clean Effects Upgrade Kit
Model Number TFD145ALUPGRDA TFD175ALUPGRDA TFD210ALUPGRDA TFD245ALUPGRDA Airflow Range 300-1200 300-1600 300-2000 400-2000 Perfect Fit Cabinet Width 14-1/2 inch 17-1/2 inch 21 inch 24-1/2 inch
1 1 2 2
Mfg. Plant VI VI VI VI
Shipping Weight 35 39 43 45
Accessories:
Model Number Description BAYTRANS12024 120 TO 24 Volt Transformer Used With All TFD Air Cleaners Mfg. Plant VI Shipping Weight 6
Features:
CleanEffects removes up to 99.98% of allergens from the filtered air Removes particles down to .1 microns in size Outperforms HEPA, and up to 100 times more effective than a standard 1 filter Constructed of heavy 18 guage metal to protect the filter and internal electronics Fits any "Perfect Fit" air cleaner cabinet Easily convert "Perfect Fit", TFP, TFM or TFE product to TRANE CleanEffects air cleaner Power door provides easy access to internal components and features a filter status display as well as safety interlocks that automatically shut down the power when the door is opened for maintenance or cleaning Designed for flush fit on both sides and rear of equipment cabinet No transitions required on CleanEffects applications Gaskets come with the air cleaner to seal out unwanted air 24 Volt input power 10 year electronics warranty 5 year parts warranty
T F D 145 A L UPGRD A A
FILTRATION ifD SIZE FURNACE 145 = 14.5" 14D= Downflow 175 = 17.5" 17D= Downflow 210 = 21" 21D= Downflow 245 = 24.5" 24D= Downflow SERVICE SEQUENCE Not Orderable MINOR DESIGN AIR HANDLER 215 = 21.5" 235 = 23.5" 260 = 26.0" APPLICATION UPGRD = Upgrade Kit POWER SUPPLY L = Low Voltage MAJOR DESIGN SERIES
IC 2
TFE145-245A9FR TFE215-260A1AH
Specifications: Electronic Air Cleaner - Furnace - 120Volt
Model Number TFE145A9FR3 TFE175A9FR3 TFE210A9FR3 TFE245A9FR3 Airflow Range 300-1200 300-1500 300-2000 400-2200 Perfect Fit Furnace Width 14-1/2 inch1 17-1/2 inch 1 21 inch2 24-1/2 inch2 Uncrated Dimensions(in.) H W D 7.5 14.5 27 7.5 17.5 27 7.5 21 27 7.5 24.5 27 Mfg. Plant TR TR TR TR
Features:
No transitions required for Perfect Fit applications. Three sizes allow flush fit with Air Handlers and four sizes allow flush fit bottom return on Furnaces. This allows for easy installation in tight spaces. The TF*175 (171/2") model can be used for a Perfect Fit side return on furnace models. Cabinet case versatility provides three levels of air filtration. All enclosures will accept 1 inch filters, 5 inch filters, or the Electronic Air Cleaner cells. Easily upgrade the media to an electronic model. Painted cabinet matches Furnace/Air Handler to enhance matched system appearance. Can be easily converted to TRANE CleanEffects whole house technology with Upgrade Kit listed on page IC-2 Air-Tite construction eliminates air leaks, improves air quality and helps keep operating costs low. Gasket is provided to seal air cleaner to indoor unit, keeping out unconditioned and unfiltered air. Heavy duty 18 gauge cabinet construction supports Furnace/Air Handler weight. All hardware included. Factory installed air flow sensor on all Electronic Air Cleaners models. No additional Power On relay or field installed accessory required. Fully regulated, solid state, power supply maintains the collection voltage at its peak, regardless of the input voltage. Soft start brings the collection voltage up gradually - thus reducing the popping noise on start-up. Three voltage selections for reducing ozone levels. Off/on switch and operation light tells if the air cleaner is on and when high voltage to the cells is present. Electronic Air Cleaners for Furnaces use a 120 volt, internally fused, power supply. Internally fused power supply for Air Handlers use the Air Handler 240 volt power. No additional electrical circuit is required. A 120 volt, internally fused, power supply model for Air Handlers also available. All service and access is from the front of the Electronic Air Cleaners. Low pressure drop and high dust holding capacity for media models. Designed to deliver the required system air flow.
T F E 145 A 9 FR 1 A
FILTER SERVICE SEQUENCE MINOR MODIFICATION CODE AH = AIR HANDLER FR = FURNACE VOLTAGE 9 = 120V 1 = 240V
TYPE
E = ELECTRONIC M = MEDIA (5 IN) P = PLEATED (1 IN) SIZE FURNACE 145 = 14.5" 175 = 17.5" 210 = 21" 245 = 24.5" AIR HANDLER 215 = 21.5" 235 = 23.5" 260 = 26"
IC 3
TF(P/M)145-245B0FR
Expandable High Efficiency Media Filter Uncrated Dimensions(in.) H W D 7.5 14.5 27 7.5 17.5 27 7.5 21.0 27 7.5 24.5 27 Mfg. Plant VI VI VI VI
Upflow Furnaces
Perfect Fit Furnace Width 14-1/2 inch1 17-1/2 inch1 21 inch2 24-1/2 inch2
Shipping Weight 18 21 24 27
Cartridge High Efficiency Media Filter Uncrated Dimensions(in.) H W D 7.5 14.5 21 7.5 17.5 21 7.5 21.0 21 7.5 24.5 21 Mfg. Plant VI VI VI VI
Downflow Furnaces
Perfect Fit Furnace Width 14-1/2 inch 17-1/2 inch 21 inch 24-1/2 inch
Shipping Weight 15 18 21 24
Features:
No transitions required for Perfect Fit applications. Four sizes allow flush fit bottom return on Furnaces. This allows for easy installation in tight spaces. The TF*175 (171/2") model can be used for a Perfect Fit side return on furnace models. Cabinet case versatility provides three levels of air filtration. All enclosures will accept 1 inch filters, 5 inch filters, or the Electronic Air Cleaner cells. Painted cabinet matches Furnace/Air Handler to enhance matched system appearance. Can be easily converted to TRANE CleanEffects whole house technology with Upgrade Kit listed on page IC-2 Air-Tite construction eliminates air leaks, improves air quality and helps keep operating costs low. Gasket is provided to seal air cleaner to indoor unit, keeping out unconditioned and unfiltered air. Heavy duty 18 gauge cabinet construction supports Furnace/Air Handler weight. All hardware included. Low pressure drop and high dust holding capacity for media models. Designed to deliver the required system air flow.
IC 4
TF(P/M)215-260B0AH
Specifications: With 5 inch Expandable High Efficiency Media Filter - Air Handlers
Model Number TFM215B0AH0 TFM235B0AH0 TFM260B0AH0 Airflow Range 300-1400 300-1700 400-2100 Perfect Fit Air Handler Width 21-1/2 inch 23-1/2 inch 26 inch Uncrated Dimensions(in.) H W D 7.5 21.5 21 7.5 23.5 21 7.5 26.0 21 Mfg. Plant VI VI VI Shipping Weight 22 24 25
No transitions required for Perfect Fit applications. Three sizes allow flush fit with Air Handlers. This allows for easy installation in tight spaces. Cabinet case versatility provides three levels of air filtration. All enclosures will accept 1 inch filters, 5 inch filters, or the Electronic Air Cleaner cells. Easily upgrade the media to an electronic model. Painted cabinet matches Furnace/Air Handler to enhance matched system appearance.
Can be easily converted to TRANE CleanEffects whole house technology with Upgrade Kit listed on page IC-2 Air-Tite construction eliminates air leaks, improves air quality and helps keep operating costs low. Gasket is provided to seal air cleaner to indoor unit, keeping out unconditioned and unfiltered air.
Heavy duty 18 gauge cabinet construction supports Furnace/Air Handler weight. All hardware included. Low pressure drop and high dust holding capacity for media models. Designed to deliver the required system air flow.
IC 5
Enclosure Mfg. Shipping Used with Plant Weight 14-1/2 TR 3 17-1/2 TR 3 21 TR 3 24-1/2 TR 3 14-1/2 TR 5 17-1/2 TR 5 21 TR 5 24-1/2 TR 6 14-1/2 TR 5 17-1/2 TR 5 21 TR 5 24-1/2 TR 6 14-1/2 - 24-1/2 TR 6 Enclosure Used with 21-1/2 23-1/2 26 21-1/2 23-1/2 26 21-1/2 23-1/2 26 21-1/2 - 26 Mfg. Shipping Plant Weight TR 3 TR 3 TR 3 TR 5 TR 5 TR 6 TR 5 TR 5 TR 6 TR 5
B A Y F T F R 1 7 M 2 A
BUSINESS UNIT ACCESSORY FILTER AH = AIR HANDLER FR = FURNACE SIZE 14 IN 23 IN 17 IN 24 IN 21 IN 26 IN DESIGN SEQUENCE QUANTITY D = DOZEN TYPE M = MEDIA (5 IN) P = PLEATED (1 IN) W=PERMANENT-Washable (1 IN)
IC 6
234 ERV
5 R
678 100
9 A
10 11 12 13 14 15 9 P 0 0 A A
IC 7
1 Percent Timer Control included with the ERV 2 Available in April 2006
Specifications: ERV
Model Number TERVR100A9P00A TERVR200A9P00A TERVR300A9P00A2
Shipping Weight 58 80 88
Apparent Sensible Effectiveness(32F) 80% @ 120 cfm 72% @ 120 cfm 44% @ 120 cfm
Sensible Recovery Effectiveness(32F) 84% @ 120 cfm 77% @ 120 cfm 63% @ 120 cfm
Latent Recovery (32F) 73% @ 251 cfm 64% @ 251 cfm 40% @ 251 cfm
Total Recovery (32F) 51% @ 63 cfm 59% @ 63 cfm 31% @ 252 cfm
Optional Accessories:
Model Number TCONTV10APBC0A BAYFLT10A1010A BAYFLT20A1020A BAYWHT10AVENTA3 BAYBRN10AVENTA3 BAYGLV10AVENTA3 Description Point of Use Push Button Control Filters - 2 per pack Filters - 2 per pack 6 inch White Vinyl Ventilation Hood 6 inch Brown Vinyl Ventilation Hood 8 inch Galvenized Ventilation Hood Used With ERV models 100, 200, 300 ERV models 100 ERV models 200, 300 ERV models 100, 200 ERV models 100, 200 ERV models 300 Mfg. Plant TY TY TY TY TY TY Shipping Weight 1 1 1 1 1 2
3 Qty 1
Features:
FreshEffects ERV technology for all seasons and climates Static plate energy transfer core for efficient transfer of heat and moisture Passive defrost - condensate drain not required Still fan curve - balancing dampers not required Multi position mounting Percent Timer (PT) control included with ERV for simple, automatic operation Optional push button control for use with PT control Cam action door latches for quick service access
Heavy gauge, powder painted steel cabinet Permanently lubricated motor bearings (ball bearings) 6 and 8 double collar duct connections for TERVR100 and 200 8 round compatible duct connection for TERVR300 Closed cell foam gasketing for insulation integrity 1 duct board insulation with cleanable foil face May be installed in conditioned and unconditioned spaces Cabinet / Door color: Trane Polyslate Gray / Tarpaulin Gray
5 year limited warranty on parts 10 year limited warranty on energy transfer core Optional extended warranty
IC 8
TAYPLUS103A THT1248
Specifications: +1 Add-On Heat Pump Control Kit
Model Number TAYPLUS103A TAYSTAT250B THT1248 Description Heat Pump Control Kit Outdoor Thermostat Bonnet Switch
Accessories
Mfg. Shipping Used With Plant Weight Gas,Oil & Electric Furnaces TY 3 TAYPLUS103A for Restricted TY 1 Mode Oil Furnaces Only 1
TAYPLUS103A
IC 9
1 Includes Automatic Humidifier Control (duct mount only) 2 Includes Automatic Humidifier Control (duct mount only) and 120/24V transformer 3 Includes Manual Humidifier Control and 120/24V transformer 4 Not applicable for horizontal installations.
Accessories:
Model Number BAYPAD02A1310A BAYPAD01A1010A TCONTH01AUTOA BAYRLY10ASENSA BAYPLT01AMHC0A
Description Large Humidifier Pad 13 x 10 Smalll Humidifier Pad 9-7/8 x 9-5/8 Automatic Humidifier Control Current Sensing Relay Adapter Plate (Duct Mount)
Mfg. Shipping Used With Plant Weight THUMD500,300A TY 1 THUMD200A TY 1 THUMD200A TY 1 All TY 1 Manual Humidifier Control TY 1
Features: THUMD500A
Flow through fan powered humidifier High performance humidifier delivers up to 18 gallons per day Humidifies an average home of up to 2100 sqft Automatic humidifier control with O.D. sensor for up to 50% more humidity Front cover access for easy replacement of humidifier pad. Aluminum humidifier pad treated with ceramic clay for for enhanced pad performance Reliable brass solenoid valve w/stainless steel valve seat UV resistant cabinet and scale control insert Saddle valve Polyslate gray housing matches furnace cabinet color 120V power line cord
THUMD500A
Features: THUMD200,300A
THUMD300A bypass delivers up to 17 gallons per day THUMD200A delivers up to 12 gallons per day. THUMD300A automatic humidifier control and O.D. sensor for up to 50% more humidity THUMD200A manual humidifier control UV resistant cabinet and scale control Insert Front cover access for easy replacement of humidifier pad. Aluminum humidifier pad treated with ceramic clay for for enhanced pad performance Reliable Brass solenoid valve w/stainless steel valve seat Field convertible duct connection,left or right side Built in summer / winter damper UV resistant cabinet and scalecontrol Insert Saddle valve Polyslate gray housing matches furnace cabinet color 24/120 V transformer
THUMD200A
IC 10 Effective date: January 1, 2007
Linesets
Specifications: Brazed Insulated Pipe
Model Number TAYREFLN115 TAYREFLN120 TAYREFLN125 TAYREFLN130 TAYREFLN140 TAYREFLN150 TAYREFLN215 TAYREFLN220 TAYREFLN225 TAYREFLN230 TAYREFLN240 TAYREFLN250 TAYREFLN315 TAYREFLN320 TAYREFLN325 TAYREFLN330 TAYREFLN340 TAYREFLN350 TAYREFLN415 TAYREFLN420 TAYREFLN425 TAYREFLN430 TAYREFLN440 TAYREFLN450 TAYREFLN515 TAYREFLN520 TAYREFLN525 TAYREFLN530 TAYREFLN540 TAYREFLN550 TAYREFLN615 TAYREFLN620 TAYREFLN625 TAYREFLN630 TAYREFLN640 TAYREFLN650 TAYREFLN715 TAYREFLN720 TAYREFLN725 TAYREFLN730 TAYREFLN740 TAYREFLN750 Gas Line Dia. O.D. 90 Bend 5/8 One end 5/8 One end 5/8 One end 5/8 One end 5/8 One end 5/8 One end 3/4 One end 3/4 One end 3/4 One end 3/4 One end 3/4 One end 3/4 One end 7/8 One end 7/8 One end 7/8 One end 7/8 One end 7/8 One end 7/8 One end 1-1/81 One end 1-1/81 One end 1-1/81 One end 1-1/81 One end 1-1/81 One end 1-1/81 One end 1/2 One end 1/2 One end 1/2 One end 1/2 One end 1/2 One end 1/2 One end 5/8 One end 5/8 One end 5/8 One end 5/8 One end 5/8 One end 5/8 One end 3/4 One end 3/4 One end 3/4 One end 3/4 One end 3/4 One end 3/4 One end Liquid Line Dia. O.D. Length 1/4 15 1/4 20 1/4 25 1/4 30 1/4 40 1/4 50 5/16 15 5/16 20 5/16 25 5/16 30 5/16 40 5/16 50 3/8 15 3/8 20 3/8 25 3/8 30 3/8 40 3/8 50 3/8 15 3/8 20 3/8 25 3/8 30 3/8 40 3/8 50 1/4 15 1/4 20 1/4 25 1/4 30 1/4 40 1/4 50 5/16 15 5/16 20 5/16 25 5/16 30 5/16 40 5/16 50 3/8 15 3/8 20 3/8 25 3/8 30 3/8 40 3/8 50 Tonages with R-22 1 & 1-1/2 1 & 1-1/2 1 & 1-1/2 1 & 1-1/2 1 & 1-1/2 1 & 1-1/2 2 & 2-1/2 2 & 2-1/2 2 & 2-1/2 2 & 2-1/2 2 & 2-1/2 2 & 2-1/2 3 & 3-1/2 3 & 3-1/2 3 & 3-1/2 3 & 3-1/2 3 & 3-1/2 3 & 3-1/2 4, 5, & 6 4, 5, & 6 4, 5, & 6 4, 5, & 6 4, 5, & 6 4, 5, & 6 Tonages Mfg. Shipping with R-410A Plant Weight TY 9 TY 11 TY 13 TY 15 TY 20 TY 28 2-1/2 TY 11 2-1/2 TY 13 2-1/2 TY 15 2-1/2 TY 18 2-1/2 TY 23 2-1/2 TY 32 4&5 TY 13 4&5 TY 16 4&5 TY 20 4&5 TY 24 4&5 TY 30 4&5 TY 39 TY 13 TY 16 TY 20 TY 24 TY 30 TY 39 1 & 1-1/2 TY 8 1 & 1-1/2 TY 11 1 & 1-1/2 TY 13 1 & 1-1/2 TY 15 1 & 1-1/2 TY 19 1 & 1-1/2 TY 26 2 TY 9 2 TY 12 2 TY 15 2 TY 17 2 TY 22 2 TY 29 3 & 3-1/2 TY 12 3 & 3-1/2 TY 15 3 & 3-1/2 TY 19 3 & 3-1/2 TY 22 3 & 3-1/2 TY 28 3 & 3-1/2 TY 35
*Gas line insulation 3/8" thickness. Gas line is 7/8 O.D. but expanded out to 1-1/8 on the ends. Note: Contains a holding charge of Nitrogen.
IC 11
A/M = Automatic or Manual Changeover Requires subbase Requires BAY24X042 relay when used with electric heaters. Specially designed for electric heater applications (instant on fan). Requires BAY24X042 relay when used with oil furnace.
1 2 3 4
TCONT800A,802A,803A
TCONT600A,602A IC 12
1Requires subbase
Features: TCONT800A,802A,803A
Easy-to-read, large, clear display with backlighting shows current temperature, set temperature and time Touch Screen Interaction allows user to navigate its intuitive menus with ease Menu Driven Programming guides the user through the scheduling process, showing only necessary information and choices on each screen Ability to select multiple days allows the homeowner to easily customize the comfort control for their unique schedules Programmable fan options (AUTO, Real-Time Clock keeps time during ON, and CIRC) increase air quality power failure and automatically updates for daylight savings when combined with a whole-house Armchair Programming allows user air cleaner and offers greater options and installer to remove comfort control for air circulation from wall to set the schedule (with Outdoor Temperature Indication (optional sensor required) shows three AAA batteries installed) outdoor temperature on the display Multiple HOLD options makes it easy to modify schedule indefinitely or for a to help you plan outdoor activities specific time period IAQ reminders prompt the homeowner to service or replace air filters and humidifier pads
TCONT600A,602A IC 13
Tracker
Light Commercial Systems
IC 14
Tracker
Tracker System CV
Ordering Number
BMTKKBBAA0A110
Expanded Description
Tracker 12 communicates with a maximum of 21 devices: Up to 12 Space Comfort Controllers (SCC) including Voyager and Precedent Rooftop units and ZN517 Unitary Controllers Up to 5 Central Control Panels (CCP) Up to 4 MP503 Multi-Purpose Input/Output controllers Tracker 24 communicates with a maximum of 38 devices: Up to 24 Space Comfort Controllers (SCC) including Voyager and Precedent Rooftop units and ZN517 Unitary Controllers Up to 10 Central Control Panels (CCP) Up to 4 MP503 Multi-Purpose Input/Output controllers The Tracker 12 with Local Area Network (LAN) option is a Tracker 12 with a 10/100 Base-T Ethernet card. The card has a RJ45 external interface (Ethernet connector), on board TCP/IP stack and can be assigned a static IP address or receive a DHCP address (dynamic address from the host server). The Tracker 24 with Local Area Network (LAN) option is a Tracker 24 with a 10/100 Base-T Ethernet card. The card has a RJ45 external interface (Ethernet connector), on-board TCP/IP stack and can be assigned a static IP address or receive a DHCP address (dynamic address from the host server).
BMTKKBBAA0A210
Tracker 24
BMTKKBBAB0A110
Tracker 12 w/LAN
BMTKKBBAB0A210
Tracker 24 w/LAN
Notes: 1. Tracker panels require a LCI/RLCI (LonTalk) comm5 communication card on each Rooftop unit (Tracker does not communicate with TCI comm3/4, VariTrac I & II, Comfort Managers or TCMs). 2. All Tracker System CV panels require a 24 VAC, 50/60 Hz power supply (sold separately). 3. Batteries not required.
Expanded Description
Up to 4 MP503 I/O Modules can be connected to a Tracker panel. MP503 inputs can be monitored, trended or used in binary output programming equations by the Tracker panel.
Notes: 1. MP503 requires a 24 VAC, 50/60 Hz power supply (sold separately) 2. MP503 has a built-in 80 mA, 24 VDC power supply capable of powering 4-20 mA transmitting sensors.
Expanded Description
The ZN517 Unitary Controller provides digital control similar to that of a wall thermostat. It is in a compact enclosure. The ZN517 controller is in accordance with the LonMark Space Comfort Controller (SCC) profile and can operate as a standalone device or as part of a Tracker light commercial system. ZN517 Unitary Controllers are suitable for the following applications: 2-heat/2-cool rooftop units with optional economizer control 4-cool rooftop units with optional economizer control 2-stage heat pumps with optional economizer and auxiliary heat control Split systems
Notes: 1. ZN517 requires an isolated 24 VAC, 50/60 Hz power supply (sold separately).
IC 15
Tracker
Universal Accessories
System Specific Accessories
Ordering Number
KBB40201206
Expanded Description
The Tracker 12 LAN Upgrade consists of a new main module with internal modem and Base-T Ethernet card. It allows one Tracker 12 to reside on an Ethernet/IP Local Area Network (LAN). The card has a RJ45 external interface (Ethernet connector), on-board TCP/IP stack and can be assigned a static IP address or receive a DHCP address (dynamic address from the host server). The Tracker 24 LAN Upgrade consists of a new main module with internal modem and 10/100 Base-T Ethernet card. It allows one Tracker 24 to reside on an Ethernet/IP Local Area Network (LAN). The card has a RJ45 external interface (Ethernet connector), on-board TCP/IP stack and can be assigned a static IP address or receive a DHCP address (dynamic address from the host server). Operators touch screen display (LCD) for use on Tracker System CB Central Control Panels (CCPs). Display (LCD) can be used to setup, monitor and control equipment and schedule up to four groups of zones with internal seven-day clock. The CCP III Relay Board provides relay contacts for connection to a conventional machine thermostat terminal board (RGYW-0) when the HVAC unit connected to the Central Control Panel (CCP) is NOT a Voyager or Precedent rooftop unit. Mounts in the CCP wiring base.
KBB40201207
VADISPLAY010
VARELAYBRD10
Expanded Description
The RJ12 to RJ12 Interface Cable is a ten-foot cable with a RJ12 plug on each end used to connect Tracker light commercial system panels to external devices. One end connects directly to the Tracker panel and the other end plugs into the appropriate adapter for connection to the desired device. The RJ12 to DB9 Female Adapter is used to connect a RJ12 to RJ12 Interface Cable to a 9-pin serial port on a personal computer. This adapter converts the RJ12 connection on the cable to a 9-pin female connection.
KBA35914262
Expanded Description
24 VDC power supply to provide power to 4-20 mA or 0-10 VDC sensors and transmitters up to a combined current of 500 mA. Requires 120 VAC at .4 Amps input. 24 VDC power supply to provide power to 4-20 mA and 0-10 VDC sensors and transmitters up to a combined current of 100 mA. Requires 24 VAC, 10 VA input. This transformer has 120/208/240 VAC primary, 24 VAC 75VA secondary, external overload circuit breakers and 18 AWG, 8-inch leads for electrical connection. Mounting options include a 1/2-inch male conduit connection for mounting on a conduit box and feet for mounting on control panels. Pre-wired adapter must be cut off to expose leads for direct connection to controllers. This transformer has 120 VAC primary, 24 VAC 40 VA secondary, internal current limiting and 18 AWG, 8-inch leads for electrical connection. Mounting options include a 1/2inch male conduit connection for mounting on a conduit box and feet for mounting on control panels.
KBA35812022
IC 16
Tracker
Universal Accessories
Universal Accessories/Binary Input Devices
Ordering Number
KBA41902006
Expanded Description
Use the Air Flow Sampling Probe with a Differential Pressure Air Flow Switch to provide repeatable measurements of static pressure. This probe mounts in a duct and is 6 (152 mm) long with a right angle at its end. It has a bard connection for (6 mm) outside diameter plastic tubing. The Differential Pressure Water Flow Switch senses the differential pressure of air or liquid. It provides proof of flow for applications such as chiller flow. The range is 8 to 60 psi with a fixed differential of 1.5 psi. It includes SPDT contacts. The Differential Pressure Air Flow Switch senses positive, negative or differential air pressure. The plated housing contains a diaphragm, a calibrating spring and a snap acting SPDT switch. The sampling connections located on each side of the diaphragm accept 1/4-inch (6 mm) outside diameter tubing. This sensor includes a cover to accept 1/2-inch conduit connections. Adjustable from 0.05-inch to 12-inch (1 mm to 47 mm) wg. The Low-Temp CutoutManual Reset protects hydronic heating and cooling coils from low temperature conditions. It has a 20-foot sensor that attaches across the face of a coil. When one or more feet of the sensor registers a temperature within the 35-45F (2-7C) setpoint, the SPDT contact opens. Switch must be manually reset. The 2135 Amp Current Sensing Switch monitors the status of fans or pumps. It includes a solid state current sensing circuit and an AC/DC output switch with setpoint adjustment, output status LED, and sensor power LED. The device usually mounts in a starter motor enclosure using the multi position-mounting bracket included. Two screw terminal connections are provided for low voltage wiring to a binary input. This device requires no external power. Output rating is .5 Amps at 24 VAC/DC.
KBA41905005
KBA41906006
Differential Pressure Water Flow Switch with enclosure Differential Pressure Air Flow Switch
KBA41901084
KBAX13310270-01
Expanded Description
This Zone Temperature Sensor consists of a thermistor on a mounting base (suitable for mounting on any flat surface), plastic cover with Trane logo and a wiring terminal strip). This Zone Temperature Sensor consists of a thermistor on a mounting base (suitable for mounting on any flat surface), plastic cover with Trane logo, integral after-hours timed override On and Cancel buttons, wiring terminal strip, and RJ12 communication port. This Zone Temperature Sensor consists of a thermistor on a mounting base (suitable for mounting on any flat surface), plastic cover with Trane logo and zone setpoint adjustment knob, wiring terminal strip and RJ12 communication port. This Zone Temperature Sensor consists of a thermistor on a mounting base (suitable for mounting on any flat surface), plastic cover with Trane logo and zone setpoint adjustment knob, integral after-hours timed override On and Cancel buttons, wiring terminal strip and RJ12 communication port. This thermistor monitors duct or water temperature. If used to monitor water temperature, the sensor requires an immersion well. Shipped with a 1/2-inch MNPT well fitting. This thermistor monitors duct temperature. It has 6-foot plenum rated wire leads. Sealed thermistor designed to mount outdoors on a 1/2-inch conduit The Stainless Steel Flush Mount Wall Temperature Sensor provides indoor zone temperature sensing. It mounts directly to a wall or junction box and has an insulated back to reduce temperature effects from the mounting surface. Ideal for locations where tampering, vandalism or damage to an ordinary wall sensor might exist. Plastic backplate that fits behind all room mounted zone temperature and humidity sensors. Covers up to 4-inch x 4-inc (102 mm x 102 mm) electrical boxes. Solid stainless steel immersion well with overall length of 4.25 inches (108 mm), extension length of 2.5 inches (63 mm) and extension diameter of 1/2 inch (13 mm). Connections are 1/2-inch external MNPT threads and 1/2-inch internal FNPT threads for sensor insertion.
KBA41901094
KBA41901090
KBA41901091 KBA41901108
IC 17
Tracker
Universal Accessories
Universal Accessories/Temperature Sensors (continued)
Ordering Number
KBA41901104
Expanded Description
Solid brass immersion well with overall length of 4.25 inches (108 mm), extension length of 2.5 inches (63 mm) and extension diameter of 1/2 inch (13 mm). Connections are 1/ 2-inch external MNPT threads and 1/2-inch internal FNPT threads for sensor insertion. The 6-foot (2 m) Duct Averaging Temperature Sensor consists of 4 thermistors in a flexible, plenum rated cable that act as a single sensor. The 20' (6.1 m) Duct Averaging Temperature Sensor consists of 4 thermistors in a flexible, plenum rated cable that act as a single sensor
KBA41901123
KBA41901122
Expanded Description
The 3% Room Relative Humidity and Temperature Sensor is a combination relative humidity sensor with accuracy of +/- 3% from 20-95% relative humidity and a 10K @ 77F thermistor. The sensors are on a mounting base (suitable for mounting on any flat surface), have a plastic cover with Trane logo, require a 24 VDC power supply and include a wiring strip with separate output terminals for each sensor. The 5% Room Relative Humidity and Temperature Sensor is a combination relative humidity sensor with accuracy of +/- 5% from 20-95% relative humidity and a 10K @ 77F thermistor. The sensors are on a mounting base (suitable for mounting on any flat surface), have a plastic cover with Trane logo, require a 24 VDC power supply and include a wiring strip with separate output terminals for each sensor. Sensor in wall mount enclosure that measures Carbon Dioxide (CO2) levels in building zones within a range of 0-2000 parts per million (ppm). Output is selectable between 4-20 mA or 0-10 VDC. Requires 24 VAC or 24 VDC power. Direct sampling duct sensor that measures Carbon Dioxide (CO2) levels in building zones within a range of 0-2000 parts per million (ppm). Output is selectable between 4-20 mA or 0-10 VDC. Requires 24 VAC or 24 VDC power
KBA41907018
KBA41904100
KBA41904101
Room Carbon Dioxide (CO2) Sensor Duct Carbon Dioxide (CO2) Sensor
Expanded Description
The 24 VAC/SPDT Relay is a general purpose switching relay. An enclosure may be required for this relay to meet electrical codes. Connections are 1/4-inch (6 mm) quick connects. Use this relay as a pilot relay for binary outputs that require higher contact ratings than TCM or MP503 outputs provide. TCM and MP503 binary outputs are rated at 24 VAC, 1 Amp, 24 VA pilot duty. The coil rating for this voltage relay is 4.0 VA inrush, 3.0 VA sealed. Contact rating is: 125 VAC: 12 FLA, 60 LRA 250 VAC: 8 FLA, 48 LRA 277 VAC: 7 FLA, 42 LRA The 24 VAC/SPDT Relay With Enclosure has SPDT contacts, nylon enclosure, and 1/2-inch (13 mm) male conduit connection. The coil rating is 11.0 VA inrush, 6.0 VA sealed. The contacts are rated for 3/4 HP at 125 VAC, or 1 HP at 240 VAC, and 8 Amps continuous. The coil leads are 18 AWG and contact leads are 12 AWG. Use this relay as a pilot relay for binary outputs that require higher contact ratings than TCM or MP503 outputs provide. TCM and MP503 binary outputs are rated at 24 VAC, 1 Amp, 24 VA pilot duty. The Four 24 VAC Pilot Relays in a Box are relays for four 24 VAC coil electrically held binary output points and are in a NEMA Type 1 enclosure with sockets. There are DPDT contacts on each relay and they are rated at 5 Amp, 120 VAC,1/2 HP, 250 VA pilot duty. The enclosure is approximately 10-1/2 inches x 5-1/2 inches x 3-1/5 inches (267 mm x 140 mm x 81 mm
KBA34303020
KBA49500340
IC 18
Expanded Description
Primary system panel for a Tracker System CB (VariTrac system). Includes optional operator display (LCD) to setup, monitor and control equipment and schedule up to four groups of zones with internal seven-day clock. May also receive time of day commands from a Tracker panel or an external time clock. Central Control Panels (CCPs) communicate with a maximum of 26 devices: 1 Constant Volume HVAC unit including Voyager and Precedent Rooftop units with TCI communications board, or third-party units with optional relay board. Up to 24 zone controllers* 1 Bypass Damper Controller* Primary system panel for a Tracker System CB (VariTrac system) as above without optional operator display (LCD). Note: Internal time clock functionality is only available on CCP models with LCD. CCPs without LCD require an external time clock or optional Tracker panel for scheduling.
VACCPONLY010
Notes: 1. If the HVAC unit that is to be connected to the CCP is a Voyager or Precedent rooftop unit with ReliaTel controls, order a TCI comm3/4 communications interface for the rooftop. 2. If the HVAC unit that is to be connected to the CCP is other than a Voyager or Precedent rooftop unit, order optional CCP III Relay Board in addition to CCP. 3. All CCP panels require a 24 VAC, 50/60 Hz power supply (sold separately). 4. Batteries not required.
IC 19
VariTrac Dampers
Bypass Dampers
Ordering Number
Bypass Dampers
Description
Expanded Description
Damper motor and gear assembly are wired to a terminal strip mounted in the bypass damper control box. A 12-foot interface cable with a polarized plug is wired and supplied with the bypass damper for connection to the VariTrac III Communicating Sensor/Bypass Control Assembly. Bypass damper is controlled by the VariTrac Central Control Panel. 6" Round Bypass Damper 8" Round Bypass Damper 10" Round Bypass Damper 12" Round Bypass Damper Rectangular Bypass Damper Rectangular Bypass Damper Rectangular Bypass Damper Rectangular Bypass Damper
6" BYPS 8" BYPS 10" BYPS 12" BYPS 14" x 12" BYPS 16" x 16" BYPS 20" x 20" BYPS 30" x 20" BYPS
Zone Dampers
Ordering Number
CHGR Dampers VADA06CHGR60 VADA08CHGR60 VADA10CHGR60 VADA12CHGR60 VADA14CHGR60 VADA16CHGR60 VARA0812CHGR10 VARA0814CHGR10 VARA0816CHGR10 VARA1016CHGR10 VARA1020CHGR10 VARA1418CHGR10 6" CHGR 8" CHGR 10" CHGR 12" CHGR 14" CHGR 16" CHGR 8" x 12" CHGR 8" x 14" CHGR 8" x 16" CHGR 10" x 16" CHGR 10" x 20" CHGR 14" x 18" CHGR
Description
Expanded Description
Zone damper motor and gear assembly are controlled by a changeover UCM. No remote heat can be energized. (Heat type 0)
Zone Dampers
Ordering Number
ELEC Dampers VADA06ELEC60 VADA08ELEC60 VADA10ELEC60 VADA12ELEC60 VADA14ELEC60 VADA16ELEC60 VARA0812ELEC10 VARA0814ELEC10 VARA0816ELEC10 VARA1016ELEC10 VARA1020ELEC10 VARA1418ELEC10 6" ELEC 8" ELEC 10" ELEC 12" ELEC 14" ELEC 16" ELEC 8" x 12" ELEC 8" x 14" ELEC 8" x 16" ELEC 10" x 16" ELEC 10" x 20" ELEC 14" x 18" ELEC
Description
Expanded Description
Zone damper motor and gear assembly with three-stage electric heat control for the local zone. Local heat disabled with primary heat. (Heat type 1)
Notes: See Data Catalog for Damper Sizing. See Factory Default Parameters.
IC 20
VariTrac Dampers
Zone Dampers
Ordering Number
NCHW Dampers
Description
Expanded Description
Zone changeover with remote heat staging capabilities. With both Primary Cool and Heat, one stage of remote heat may be energized. May be used to operate a normally closed water valve. (Heat type 5)
VADA06NCHW60 VADA08NCHW60 VADA10NCHW60 VADA12NCHW60 VADA14NCHW60 VADA16NCHW60 VARA0812NCHW10 VARA0814NCHW10 VARA0816NCHW10 VARA1016NCHW10 VARA1020NCHW10 VARA1418NCHW10
6" NCHW 8" NCHW 10" NCHW 12" NCHW 14" NCHW 16" NCHW 8" x 12" NCHW 8" x 14" NCHW 8" x 16" NCHW 10" x 16" NCHW 10" x 20" NCHW 14" x 18" NCHW
Notes: See Data Catalog for Damper Sizing. See Factory Default Parameters.
IC 21
VariTrac
Accessories
Accessories
Ordering Number
VAOCCSENS010
Description
Zone Occupancy Sensor (ceiling mount)
Expanded Description
VAC02ZONE010
VAC02DUCT010
VADIGITLSNR1
VADMPRCABL10
VACOMMSENS10
Ceiling mount PIR occupancy sensor to be used with VariTrac zone damper UCM for controlling the occupied zone standby function. Detects motion over a 360 degree range (adjustable) for up to a 1200 square foot area. SPDT isolated contact for connection to UCM input. Requires 24 VAC. (may share power supply with UCM) Zone C02 Compact wall mount transmitter for use with the VariTrac UCM CO2 input for doing Sensor (wall mount) demand control ventilation. Measurement range of 2000ppm CO2 input with an output of 010vdc. Transmitter housing size is approximately 4.25inches wide by 3.15 inches high. Requires 24 VAC. Duct C02 Sensor Compact zone return duct mount transmitter for use with the VariTrac UCM CO2 input (duct mount) for doing demand control ventilation. Measurement range of 2000ppm CO2 input with an output of 0-10vdc. Transmitter housing size is approximately 4.25inches wide by 3.15 inches high by 2.5 inches deep. Duct probe is .6 inches in diameter by 3 inches to 5.5 inches, adjustable depth. Requires 24 VAC. Digital Display Digital LCD display zone sensor with the look and functionality of the standard Trane Zone Sensor zone sensor. Sensor includes digital display of setpoint adjustment and space temperature in F or C. Includes ON and CANCEL buttons(supports the *, ** service functions of the standard sensor), and communications jack which can be accessed without removing the cover. Nonvolatile memory stores last programmed setpoints. Requires 24VAC. (may share power supply with UCM) Bypass Damper Cable for wiring existing bypass dampers to the new Communicating Sensor/Bypass Cable Harness Control Assembly. Plenum rated 3 conductor cable assembly with fork connectors on one end to attach to bypass damper and AMPs connector on the other end to mate with the VAV UCM actuator output. For retrofit work only(cable is included with all new bypass dampers). Communicating One required per VariTrac system. Integrated supply air and static pressure sensors Sensor/Bypass connected to a communicating controller (UCM). Communicates directly to the VariTrac Control system over Comm4 link. Wires to the bypass damper with 12 foot interface cable (supplied with bypass damper). Requires 24 VAC. Works with new VariTrac III only. Damper UCM UCM in a damper control box; used to represent large constant volume zones. The motor actuator is by others. 277 Volt Transformer 277-volt primary, 24-volt secondary, 40 VA transformer. It is field mounted and wired. 120 Volt Transformer 120-volt primary, 24-volt secondary, 40 VA transformer. It is field mounted and wired. Actuator Only Direct coupled actuator with 60 second drive time Zone Sensor Sensor only. Vertical single-gang mounting. Zone Sensor Sensor, externally adjustable setpoint, communication jack. Vertical single-gang mounting. Zone Sensor Sensor, Night Setback button, externally adjustable setpoint, communication jack, cancel. Vertical single-gang mounting. Zone Sensor Sensor with On and Cancel. Vertical single mounting. Zone Sensor Wall Plate Available for use with UCM zone sensors. Designed to cover a 4 x 4 junction box mounted horizontally or vertically. Construction is of thermoplastic material with pebble grain finish, which matches the zone sensor. This is a field-installed component.
IC 22
VariTrac
Linear Slot Diffusers
Linear Slot Diffusers
Ordering Number
VA2TBAR1S1W0
Description
15/16" T-Bar, 2 ft., Low height, 1 slot / 1 way diffuser / inlet diameter 6" 15/16" T-Bar, 2 ft., Low height, 2 slot / 2 way diffuser 15/16" T-Bar, 4 ft., Low height, 1 slot / 1 way diffuser / inlet diameter 6" 15/16 T-Bar, 4 ft., Low height, 2 slot / 2 way diffuser / inlet diameter 6"
Expanded Description
Linear slot diffuser designed to mount over the T of several exposed T suspended ceilings. Ceiling types include Armstrong-Prelude Series, Chicago Metallic 200/1800 Series, USG/Donn-DX Series, National Rolling Mills-ML Series. Exposed surfaces of slot finished with white enamel. Linear slot diffuser designed to mount over the T of several exposed T suspended ceilings. Ceiling types include Armstrong-Prelude Series, Chicago Metallic 200/1800 Series, USG/Donn-DX Series, National Rolling Mills-ML Series. Exposed surfaces of slot finished with white enamel. Linear slot diffuser designed to mount over the T of several exposed T suspended ceilings. Ceiling types include Armstrong-Prelude Series, Chicago Metallic 200/1800 Series, USG/Donn-DX Series, National Rolling Mills-ML Series. Exposed surfaces of slot finished with white enamel. Linear slot diffuser designed to mount over the T of several exposed T suspended ceilings. Ceiling types include Armstrong-Prelude Series, Chicago Metallic 200/1800 Series, USG/Donn-DX Series, National Rolling Mills-ML Series. Exposed surfaces of slot finished with white enamel.
VA2TBAR2S2W0
VA4TBAR1S1W0
VA4TBAR2S2W0
IC 23
Z
Product Type Z = Zoning Product Family
0820 A L
SM A 0
Product Level or Type D = Damper or Duct Mount Item S = Single or Two Stage U = Universally Applied Y = Accessory Z = Zone Only - Must Be Applied with Another Zone Product Product Description, Use, or Size SENS = Sensor CNTR = Controller EXPD = Expander Board CARD = Card STAT = Thermostat or Display Sensor MTRA = Motor, Actuator
Product Service Code Minor Modification Code Product Options/Factory Options SM = Side Mount Actuator BM = Bottom Mount Actuator FO = Full Modulating, Multi-Positional P5 = Programmable, Case Size 5 S5 = Sensor Only, Case Size 5 MS = Master Scheduler Electrical Characteristics L = 24 Volts 1 = 230/60/1 9 = 115/60/1 0 = No Electric
IC 24
IC 25
IC 26
IC 27
Specifications:
Model Number ZSASSMAL010 ZSCNTRAL010 ZZEXPDAL010 ZZCARDAL010 ZZSENSAL011 ZUSTATAL0310 ZUSTATALS510 ZUSTATALP510 ZUSTATALMS10 TAYSTAT265B Description Zoning Assembly1 Single/Two-Stage Controller (two-piece thermostat) Four-Zone Expander Board Zone/By-Pass Card Remote Analog Temperature Sensor2 Reduced Size, Temperature Only Display Sensor Non-Setback Sensor Time/Temperature Display Programmable Sensor Time/Temperature Display Programmable Master Scheduler Setback/Up Sensor/for up to Eight Zones Outdoor Temperature Sensor3 Mfg. Plant TY TY TY TY TY TY TY TY TY TY Shipping Weight 9 4 1 1 1 1 1 1 1 1
1 Contains a system controller, four-zone expander board, and three zone cards mounted in a large eight zone metal enclosure. Discharge air sensor packaged with assembly. 2 Requires ZUSTATALMS10 for programming and scheduling when used as a zone sensor. 3 Use for outdoor temperature reading.
Features and Benefits:
Full modulating zone operation Single and two-stage heating products Single and two-stage cooling products Indoor fan motors -- handles both Variable Speed and PSC induction motors Heat pump compatible Fossil fuel (gas and oil furnace) compatible Wet-heat (hot water coil in air handler) compatible Zone card adjustable from 20 to 100% system airflow By-pass offering Relief to zones adjustment (standard feature)
ZUSTATAL0310
ZUSTATALP510
ZSASSMAL010 ZUSTATALMS1
IC 28
Expanded Description Contains the Basic Control components (excluding wall mounted sensors) for either I) a three (3) zone system, or II) a two (2) zone system with by-pass. Includes the system controller, one (1) fourzone expander board with three (3) zone cards. All mounted in a metal enclosure that will accept an additional four-zone expander board for up to eight (8) zones. Discharge Air Sensor is packaged and included. Controls single and two-stage products; cooling, gas, oil, electric heat, and heat pump systems. . Must be used with any ZUSTATAL** Wall Mounted Sensor. Use as a two-piece thermostat remoting the relays and noise the relays normally produce. User sees attractive wall mounted assembly. Controller can be used to allow communication link between cooling/ heating equipment and home automation control(s). Controls cooling, gas, oil, electric heat, and heat pump systems. Used to expand ZSASSMAL010 Basic Zoning Assembly to either eight (8) zones or seven (7) zones with by-pass. Controls a single zone's damper(s) or the by-pass damper. Zone and by-pass airflows are set on each card. One card required per zone. Slimline design comfort sensor continuously displays indoor temperature. Used to change indoor temperature settings and conditioning modes for cool, heat, auto, or continuous fan. When used with TAYSTAT265B sensor, outdoor temperature can be viewed. Used with either ZSASSMAL010 or ZSCNTRAL010.
ZSCNTRAL010
Single/Two-Stage Controller
ZZEXPDAL010
ZZCARDAL010
Zone/By-Pass Card
ZUSTATAL031
ZUSTATALS51
Comfort sensor continuously displays the time and indoor temperature backlit LCD for easy view. Used to change indoor temperature settings and conditioning modes. When used with TAYSTAT265B sensor, outdoor temperature can be viewed. Use with either ZSASSMAL010 or ZSCNTRAL010.
ZUSTATALP51
Same basic features as ZUSTATALS510 sensor with seven day schedule programming which allows four separate time/tempeature settings per 24-hour period. Backlit LCD for easy view and programming. Displays day of week in addition to time and temperature.
ZUSTATALMS1
Same features as ZUSTATALP510 sensor. Can be used to program and schedule up to eight (8) zones. Copy button for ease of programming time/temperature schedules from other zones.
ZZSENSAL011
Temperature only sensor. Senses the temperature where located. When used for a zone temperature sensor, must be used with ZUSTATALMS1 Master Scheduler. Can be used as a remote sensor for ZUSTATALS51, ZUSTATALP51, or ZUSTATALMS1. Outdoor temperature only sensor. Can be used with ZUSTATALS51, ZUSTATALP51, or ZUSTATALMS1.
TAYSTAT265B
IC 29
Accessories: Heat Pump Non-Bleed TXV Kits (also for cooling) - Dual direction flow
Model Number TAYTXVH0B3C TAYTXVH0C3C TAYTXVH0E3C TAYTXVH0G3C TAYTXVH0H3C Liquid Line Used With Connection HP/AC Units Dia. I.D. 1-1.5 Ton 1/4" 2-2.5 Ton 5/16" 3-3.5 Ton 3/8" 4 Ton HP 3/8" 5-6 Ton HP 3/8" Mfg. Plant TR TR TR TR TR Shipping Weight 2 2 2 2 2 Refrigerant R22 R22 R22 R22 R22
Accessories: R-410A Heat Pump Non-Bleed TXV Kits (also for cooling) - Dual direction flow
Model Number 4AYTXVH3A1830A 4AYTXVH3A3654A 4AYTXVH3A6060A Used With HP/AC Units 1.5-2.5 Ton 3-4 Ton 5 Ton Mfg. Plant TR TR TR Shipping Weight 2 2 2 Refrigerant R410A R410A R410A
1 1 1/2 ton requires 1/4" liquid line; reducer fittings provided. 2 1 1/2 ton requires 1/2 " suction line, 2 ton requires 5/8; reducer fittings provided. 3 3 & 3 1/2 ton requires 3/4" suction line; reducer fitting provided.
* Used with TXH coils only where approved for use with 2 compressor systems.
Notes:
Use in place of FCCV (Above) on air handlers and coils Match TXV kit size to outdoor nominal cooling capacity Braze field connections
IC 30
Heat Pump Non-Bleed TXV Thermal Expansion w/Mechanical Fittings Valve Accessories
Accessories: R-22 HP Non-Bleed TXV Kits (also cooling) - Dual Direction Flow for COILS
Model Number 2AYTXVH3C1818A 2AYTXVH3C2425A 2AYTXVH3C3031A 2AYTXVH3C3337A 2AYTXVH3C4243A 2AYTXVH3C4850A 2AYTXVH3C5463A Used With HP/AC Units 1.5 Ton 2 Ton 2.5 Ton 3 Ton 3.5 Ton 4 Ton 4 and 5 Ton A Coils1 018 024-025 048-060 036-037 042-043 048-050 060-061 Flat Coils2 018 033 041 054,063 Mfg. Plant TR TR TR TR TR TR TR Shipping Weight Refrigerant 2 R-22 2 R-22 2 R-22 2 R-22 2 R-22 2 R-22 2 R-22
1 2TXC,CXC,CXA 2 2TXF
Accessories: R-22 HP Non-Bleed TXV Kits (also cooling) - Dual Direction Flow for AIR HANDLERS
Model Used With Number HP/AC Units 2AYTXVH3D1830A 1.5-2.5 Ton 2AYTXVH3D3636A 3 Ton 2AYTXVH3D4260A 3.5-5 Ton Air Handlers TEC/TEH018-030, TGB018-036 TFB/TFE-All TEC/TEH036 TEC/TEH042-060, TGB042-048 Mfg. Plant TR TR TR Shipping Weight 2 2 2 Refrigerant R-22 R-22 R-22
Accessories: R-410A HP Non-Bleed TXV Kits (also cooling) - Dual Direction Flow for COILS & AIR HANDLERS
Model Number 4AYTXVH3D1831A 4AYTXVH3D3343A 4AYTXVH3D4863A Used With HP/AC Units 1.5-2.5 Ton 3-3.5 Ton 4-5 Ton A/Flat Coils1 018-031 036-043 048-061 Air Mfg. Handlers Plant TR TR TR
1 2 3 4
2 3 4
Accessories: R-22 HP Non-Bleed TXV Kits (also cooling) - Dual Direction Flow for ALUMINUM COILS
Model Number 2AYTXVH3B2531A 2AYTXVH3B3637A 2AYTXVH3B5454A 2AYTXVH3B6161A 2AYTXVH3B6565A Used With HP/AC Units 2-2.5 Ton 3 Ton 4 Ton 5 Ton 5 Ton
Accessories: R-410A HP Non-Bleed TXV Kits (also cooling) - Dual Direction Flow for ALUMINUM COILS
Model Number 4AYTXVH3B2531A 4AYTXVH3B3654A 4AYTXVH3B6165A Used With HP/AC Units 2-2.5 Ton 3-3.5 Ton 4-5 Ton Aluminum Coils1 025-031 036-054 061-065 Mfg. Plant TR TR TR Shipping Weight 2 2 2 Refrigerant R-410A R-410A R-410A
1 4TXC-S
M NU I M LU A
IC 31
Mfg. Plant TR TR TR TR TR
Shipping Weight 2 2 2 2 2
Aluminum 'A' Coils (Cooling/Heat Pump Non-Bleed TXV Kits-/Dual Direction Flow)
R-410 Model Number 4AYTXVH3B2531A 4AYTXVH3B3654A 4AYTXVH3B3654A 4AYTXVH3B6165A 4AYTXVH3B6165A R-22 Model Number 2AYTXVH3B2531A 2AYTXVH3B3637A 2AYTXVH3B5454A 2AYTXVH3B6161A 2AYTXVH3B6565A Used With Aluminum Coils 2/4TXC-025-031 2/4TXC-036,037 2/4TXC-054 2/4TXC-061 2/4TXC-065
IC 32
T C Y 4 0 4 8 A 3 0 0 0 AA
PC 1
Features:
Variable speed indoor blower motors with Comfort-R airflow system Architecturally integrated louvers and corner guards deliver durable protection, extra safety, and great looks Weather Beater Top contoured for great appearance and reinforced for strength Ultra quiet operation provides bestin-class performance with barely noticeable sound levels Appliance grade finish of durable powder paint baked on both sides of the panels Exclusive Climatuff high efficiency compressor with internal overload protection Ducted outdoor fan with a high efficiency motor for quiet and reliable operation Semi-Elliptical, Logarithmic Expansion Composite Vortica blower provides better airflow and less sound while using less energy Spine Fin outdoor coil for long lasting performance and durability Right side electrical service for high and low voltage connections Rugged steel basepan features deep drawn duct connections and emergency drains Steeply sloped composite drainpan will empty fast and never rust Ships in horizontal configuration and converts quickly for downflow Complete set of customized electric heaters designed for all models. Features a polarized plug for easy installation Optional filter rack kits fit inside the unit. Available for 1" or 2" media Non-bleed expansion valves on indoor coils Pressure taps easily accessed and protected inside compressor compartment Easy access liquid line tap inside compressor compartment Standard operation to 55F as manufactured Low ambient cooling to 0F with kit UL approved and listed 10 year compressor, 10 year outdoor coil, and 5 year other parts limited warranty (Residential Use Only) Optional extended warranty
PC 2
7 7 6
PC 3
Model Mfg. Shipping Number Description Used With Plant Weight Extended Warranties (1 yr - 5 yr - 10 yr See Extended Warranty Section) Controls (See Controls Section) BAYCURB050A Roof Curb (Flat Roof)25 4TCY4024-036A FS/200 74 BAYCURB051A Roof Curb (Flat Roof)26 4TCY4048-060A FS/200 74 BAYECON101A 0-100% Mod. Economizer w/Baro. Relief1347 4TCY4024-036A FS/200 50 BAYECON102A 0-100% Mod. Economizer w/Baro. Relief1347 4TCY4048-060A FS/200 65 BAYECON200A 0-100% Mod. Econ. - Horizontal13 4TCY4024-036A FS/200 85 BAYECON201A 0-100% Mod. Econ. - Horizontal13 4TCY4048-060A FS/200 85 BAYSTAT023 Remote Potentiometer All Economizers CK/001 1 BAYENTH001A Enthalpy Control (Solid State)3 All Economizers FS/200 2 BAYOSAH001A 0-25% Manual Fresh Air Damper14 4TCY4024-036A FS/200 6 BAYOSAH002A 0-25% Manual Fresh Air Damper14 4TCY4048-060A FS/200 8 BAYDMPR101A Motorized Fresh Air Damper14 4TCY4024-036A FS BAYDMPR102A Motorized Fresh Air Damper14 4TCY4048-060A FS BAYFLTR101A 1"-2" Filter Frame1 (20x25 filter not included) 4TCY4024-036A FS/200 6 BAYFLTR201A 1"-2" Filter Frame1 (20x20,20x18 filters not included) 4TCY4048-060A FS/200 6 BAYLOAM011A Evaporator Defrost Control Kit All 4TCY4 TY 5 BAYLOAM105A Low Ambient Control Kit All 4TCY4 FS/200 5 BAYQSTK300A Quick Start Kit All 4TCY-A1 BAYCCHT101A Crankcase Heater - 230v - Recip 4TCY4024A1 BAYCCHT102A Crankcase Heater - 230v - Scroll 4TCY4036,48,60A1/3 BAYSQRD001A 16" Round Duct Adapter (2 Per Box)8 4TCY4024-036A FS/200 5 BAYSQRD002A 18" Round Duct Adapter (2 Per Box)8 4TCY4024-060A FS/200 3 BAYADAP050A Adapter Curb 4TCY4024-036A to BAYCURB030,38 BAYADAP051A Adapter Curb 4TCY4024-036A to BAYCURB033 BAYADAP052A Adapter Curb 4TCY4048-060A to BAYCURB030,38 BAYADAP053A Adapter Curb 4TCY4048-060A to BAYCURB033 BAYADAP054A Adapter Curb 4TCY4048-060A to BAYCURB034 BAYUTIL101A Roof Curb Utility Extention Kit 4TCY4024-036A BAYUTIL102A Roof Curb Utility Extention Kit 4TCY4048-060A BAYCOVR112A 12" Duct Shroud Covers Horizontal9 4TCY4024-060A BAYCOVR118A 18" Duct Shroud Covers Horizontal9 4TCY4024-060A BAYEXMK001A Extreme Condition Mounting Kit - All BAYCURB & BAYADAP BAYEXMK002A Extreme Condition Mounting Kit - All BAYUTIL BAYEXMK003A Extreme Condition Mounting Kit - All Slab Mounts BAYLIFT002B Lifting Lug Kit All 4TCY4 FS/200 5
1 Must use filter frame when economizer/fresh air kit is used. 2 Ships knocked down. 3 Dry bulb control standard with economizer. 4 Downflow Only. 5 Full perimeter curb for 4TCY4024-036A. 6 Full perimeter curb for 4TCY4048-060A. 7 2-Stage thermostat provides additional energy savings if simultaneous economizer and compressor operation is expected. 8 It is the responsibility of the installing dealer to properly size the ductwork for each specific application. 9 BAYCOVR112,118A will not cover BAYSQRD002A applications
PC 4
Features:
All steel louvers and cabinet for rugged, long lasting protection Weather Beater Top contoured for great appearance and reinforced for strength Quiet operation delivers great inhome comfort with minimal sound Appliance grade finish of durable powder paint baked on both sides of the panels Exclusive Climatuff high efficiency compressor with internal overload protection High efficiency outdoor fan motor for quiet and reliable operation Composite Vortica blower provides better airflow and less sound while using less energy Spine Fin outdoor coil for long lasting performance and durability Right side electrical service for high and low voltage connections Rugged steel basepan features deep drawn duct connections and emergency drains Steeply sloped composite drainpan will empty fast and never rust Ships in horizontal configuration and converts quickly for downflow Complete set of electric heaters featuring a polarized plug for easy installation Refrigerant line filter drier Optional filter rack kits fit inside the unit. Available for 1" or 2" media Non-bleed expansion valves on indoor and outdoor coils Direct drive multi-speed indoor blower motors Pressure taps easily accessed and protected inside compressor compartment Easy access liquid line tap inside compressor compartment Standard operation to 55F as manufactured Low ambient cooling to 0F with kit UL approved and listed 5 year compressor and other parts limited warranty. (Residential Use Only) Optional extended warranty
PC 5
BAYSPEK063B BAYSPEK064B
FS/200 FS/200
7 6
PC 6
Model Mfg. Shipping Number Description Used With Plant Weight Extended Warranties (1 yr - 5 yr - 10 yr See Extended Warranty Section) Controls (See Controls Section) BAYCURB050A Roof Curb (Flat Roof)25 4TCC3018-036A FS/200 74 BAYCURB051A Roof Curb (Flat Roof)26 4TCC3042-060A FS/200 74 BAYECON101A 0-100% Mod. Economizer w/Baro. Relief1347 4TCC3018-036A FS/200 50 BAYECON102A 0-100% Mod. Economizer w/Baro. Relief1347 4TCC3042-060A FS/200 65 BAYECON200A 0-100% Mod. Econ. - Horizontal137 4TCC3018-036A FS/200 85 BAYECON201A 0-100% Mod. Econ. - Horizontal137 4TCC3042-060A FS/200 85 BAYSTAT023 Remote Potentiometer All Economizers CK/001 1 BAYENTH001A Enthalpy Control (Solid State)3 All Economizers FS/200 2 BAYOSAH001A 0-25% Manual Fresh Air Damper14 4TCC3018-036A FS/200 6 BAYOSAH002A 0-25% Manual Fresh Air Damper14 4TCC3042-060A FS/200 8 BAYDMPR101A Motorized Fresh Air Damper14 4TCC3018-036A FS BAYDMPR102A Motorized Fresh Air Damper14 4TCC3042-060A FS BAYFLTR101A 1"-2" Filter Frame1 (20x25 filter not included) 4TCC3018-036A FS/200 6 BAYFLTR201A 1"-2" Filter Frame1 (20x20,20x18 filters not included) 4TCC3042-060A FS/200 6 BAYLOAM011A Evaporator Defrost Control Kit All 4TCC3 TY 5 BAYLOAM105A Low Ambient Control Kit All 4TCC3 FS/200 5 BAYQSTK300A Quick Start Kit All 4TCC-A1 BAYCCHT101A Crankcase Heater - 230v - Recip 4TCC3018,24A1 BAYCCHT102A Crankcase Heater - 230v - Scroll 4TCC3030,36,42,48,60A1/3 BAYCCHT404B Crankcase Heater - 460v - Scroll 4TCC3036,48,60A4 BAYSQRD001A 16" Round Duct Adapter (2 Per Box)8 4TCC3018-036A FS/200 5 BAYSQRD002A 18" Round Duct Adapter (2 Per Box)8 4TCC3018-060A FS/200 3 BAYADAP050A Adapter Curb 4TCC3018-036A to BAYCURB030,38 BAYADAP051A Adapter Curb 4TCC3018-036A to BAYCURB033 BAYADAP052A Adapter Curb 4TCC3042-060A to BAYCURB030,38 BAYADAP053A Adapter Curb 4TCC3042-060A to BAYCURB033 BAYADAP054A Adapter Curb 4TCC3042-060A to BAYCURB034 BAYUTIL101A Roof Curb Utility Extention Kit 4TCC3018-036A BAYUTIL102A Roof Curb Utility Extention Kit 4TCC3042-060A BAYCOVR112A 12" Duct Shroud Covers Horizontal9 4TCC3018-036A BAYCOVR118A 18" Duct Shroud Covers Horizontal9 4TCC3018-036A BAYEXMK001A Extreme Condition Mounting Kit - All BAYCURB & BAYADAP BAYEXMK002A Extreme Condition Mounting Kit - All BAYUTIL BAYEXMK003A Extreme Condition Mounting Kit - All Slab Mounts BAYLIFT002B Lifting Lug Kit All 4TCC3 FS/200 5
1 Must use filter frame when economizer/fresh air kit is used. 2 Ships knocked down. 3 Dry bulb control standard with economizer. 4 Downflow Only. 5 Full perimeter curb for 4TC*3018-036A. 6 Full perimeter curb for 4TC*3042-060A. 7 2-Stage thermostat provides additional energy savings if simultaneous economizer and compressor operation is expected. 8 It is the responsibility of the installing dealer to properly size the ductwork for each specific application. 9 BAYCOVR112,118A will not cover BAYSQRD002A applications
PC 7
Features:
Architecturally integrated louvers and corner guards deliver durable protection, extra safety, and great looks Weather Beater Top contoured for great appearance and reinforced for strength Ultra quiet operation provides bestin-class performance with barely noticeable sound levels Appliance grade finish of durable powder paint baked on both sides of the panels Exclusive Climatuff high efficiency compressor with internal overload protection Ducted outdoor fan with a high efficiency motor for quiet and reliable operation Composite Vortica blower provides better airflow and less sound while using less energy Spine Fin outdoor coil for long lasting performance and durability Right side electrical service for high and low voltage connections Rugged steel basepan features deep drawn duct connections and emergency drains Steeply sloped composite drainpan will empty fast and never rust Ships in horizontal configuration and converts quickly for downflow Complete set of electric heaters featuring a polarized plug for easy installation Refrigerant line filter drier Optional filter rack kits fit inside the unit. Available for 1" or 2" media Non-bleed expansion valves on indoor and outdoor coils Direct drive multi-speed indoor blower motors Pressure taps easily accessed and protected inside compressor compartment Easy access liquid line tap inside compressor compartment Standard operation to 55F as manufactured Low ambient cooling to 0F with kit UL approved and listed 10 year compressor, 10 year outdoor coil, and 5 year other parts limited warranty (Residential Use Only) Optional extended warranty
PC 8
BAYSPEK063B BAYSPEK064B
FS/200 FS/200
7 6
PC 9
Model Mfg. Shipping Number Description Used With Plant Weight Extended Warranties (1 yr - 5 yr - 10 yr See Extended Warranty Section) Controls (See Controls Section) BAYCURB050A Roof Curb (Flat Roof)25 4TCX3018-036A FS/200 74 BAYCURB051A Roof Curb (Flat Roof)26 4TCX3042-060A FS/200 74 BAYECON101A 0-100% Mod. Economizer w/Baro. Relief1347 4TCX3018-036A FS/200 50 BAYECON102A 0-100% Mod. Economizer w/Baro. Relief1347 4TCX3042-060A FS/200 65 BAYECON200A 0-100% Mod. Econ. - Horizontal137 4TCX3018-036A FS/200 85 BAYECON201A 0-100% Mod. Econ. - Horizontal137 4TCX3042-060A FS/200 85 BAYSTAT023 Remote Potentiometer All Economizers CK/001 1 BAYENTH001A Enthalpy Control (Solid State)3 All Economizers FS/200 2 BAYOSAH001A 0-25% Manual Fresh Air Damper14 4TCX3018-036A FS/200 6 BAYOSAH002A 0-25% Manual Fresh Air Damper14 4TCX3042-060A FS/200 8 BAYDMPR101A Motorized Fresh Air Damper14 4TCX3018-036A FS BAYDMPR102A Motorized Fresh Air Damper14 4TCX3042-060A FS BAYFLTR101A 1"-2" Filter Frame1 (20x25 filter not included) 4TCX3018-036A FS/200 6 BAYFLTR201A 1"-2" Filter Frame1 (20x20,20x18 filters not included) 4TCX3042-060A FS/200 6 BAYLOAM011A Evaporator Defrost Control Kit All 4TCX3 TY 5 BAYLOAM105A Low Ambient Control Kit All 4TCX3 FS/200 5 BAYQSTK300A Quick Start Kit All 4TCX-A1 BAYCCHT101A Crankcase Heater - 230v - Recip 4TCX3018,24A1 BAYCCHT102A Crankcase Heater - 230v - Scroll 4TCX3030,36,42,48,60A1/3 BAYCCHT404B Crankcase Heater - 460v - Scroll 4TCX3036,48,60A4 BAYSQRD001A 16" Round Duct Adapter (2 Per Box)8 4TCX3018-036A FS/200 5 BAYSQRD002A 18" Round Duct Adapter (2 Per Box)8 4TCX3018-060A FS/200 3 BAYADAP050A Adapter Curb 4TCX3018-036A to BAYCURB030,38 BAYADAP051A Adapter Curb 4TCX3018-036A to BAYCURB033 BAYADAP052A Adapter Curb 4TCX3042-060A to BAYCURB030,38 BAYADAP053A Adapter Curb 4TCX3042-060A to BAYCURB033 BAYADAP054A Adapter Curb 4TCX3042-060A to BAYCURB034 BAYUTIL101A Roof Curb Utility Extention Kit 4TCX3018-036A BAYUTIL102A Roof Curb Utility Extention Kit 4TCX3042-060A BAYCOVR112A 12" Duct Shroud Covers Horizontal9 4TCX3018-036A BAYCOVR118A 18" Duct Shroud Covers Horizontal9 4TCX3018-036A BAYEXMK001A Extreme Condition Mounting Kit - All BAYCURB & BAYADAP BAYEXMK002A Extreme Condition Mounting Kit - All BAYUTIL BAYEXMK003A Extreme Condition Mounting Kit - All Slab Mounts BAYLIFT002B Lifting Lug Kit All 4TCX3 FS/200 5
1 Must use filter frame when economizer/fresh air kit is used. 2 Ships knocked down. 3 Dry bulb control standard with economizer. 4 Downflow Only. 5 Full perimeter curb for 4TC*3018-036A. 6 Full perimeter curb for 4TC*3042-060A. 7 2-Stage thermostat provides additional energy savings if simultaneous economizer and compressor operation is expected. 8 It is the responsibility of the installing dealer to properly size the ductwork for each specific application. 9 BAYCOVR112,118A will not cover BAYSQRD002A applications
PC 10
PC 11
Mfg. Shipping Plant Weight FS/200 334 FS/200 338 FS/200 344 FS/200 355
Description (See Extended Warranty Section) Low Ambient Cooling Kit Anti-Short Cycle Timer
Shipping Weight 5 1
Climatuff compressor Compressor motor overload protection Energy Saving Demand defrost control system Copper tube, aluminum plate fin coils Shaft-down outdoor fan system Steeply sloped composite drain pan eliminates standing water Waterproof closed-cell foam evaporator base insulation Weather resistant powder paint Powder painted base pan 14" round duct connections included Wrap-around vinyl-coated wire coil guards
Extra quiet 74-78 dB operation Thermal expansion valves External pressure taps for refrigerant checks Polarized plug for easy field connection of low voltage to supplementary heaters Low ambient cooling to 45 F as manufactured Low ambient cooling to 0 F with accessory BAYLOAM011A UL listed 5-year limited warranty on compressor, and 5-year on all other parts (Residential Use Only) Optional extended warranties
PC 12
Over (supply) under (return) air configuration Climatuff compressor Compressor motor overload protection Internal pressure relief valve Copper tube, aluminum plate fin coils Pressure taps for refrigerant check Top discharge condensing fan Indoor fan relay Top access to supplementary heater Polarized plug for easy field connection of low voltage to supplementary heaters
Heavy gauge steel cabinet Expansion valve on indoor coil Weather resistant Powder Paint Multi-speed direct drive blower motor Variable speed direct drive blower motor on TCH042C1, TCH048-060F models Factory installed wrap-around coil guard Low ambient cooling to 45F as manufactured Low ambient cooling to 0F with accessory BAYLOAM011A UL listed
5-year limited warranty on compressor, 5-year on other parts (Residential Use) Optional extended warranties
PC 13
Used With All Cooling / Heat Pump TCONT800A,802A,803A TCONT800A,802A,803A TCONT800A,802A,803A All Cooling/Heat Pump TCONT600A All Cooling/Heat Pump TCONT401,402 All Cooling/Gas Models All Cooling Models All TCH Models All TCH Models
PC 14
Model Nomenclature
T 1
S 2
C 036 A 3 4,5,6 7
3 8
R B A ** C 0 0 0 A 1 9 10 11 12,13 14 15 16 17 18 19
E = Economizer, Reference Enthalpy 0-100% without Barometric Relief12 F = Economizer, Reference Enthalpy 0-100% with Barometric Relief12 G = Economizer, Comparative Enthalpy 0-100% without Barometric Relief12 H = Economizer, Comparative Enthalpy 0-100% with Barometric Relief12 DIGIT 15 - Supply Fan/Drive Type/Motor 0 = Standard Driveu 1 = Oversized Motor 2 = Optional Belt Drive Motor DIGIT 16 - Hinged Service Access & Filters 0 = Standard Panels & Standard Filters A = Hinged Access Panels & Standard Filters B = Standard Panels & 2" Pleated Filters C = Hinged Access Panels & 2" Pleated Filters DIGIT 17 - Condenser Coil Protection 0 = Standard Coil 1 = Standard Coil with Hail guard 2 = Black Epoxy Coated Condenser Coil 3 = Black Epoxy Coated Condenser Coil with Hail Guard
DIGIT 1 - Unit Function T = DX Cooling Y = DX Cooling, Gas Heat DIGIT 2 - Efficiency S = Standard Efficiency H = High Efficiencyo DIGIT 3 - Airflow C = Convertible DIGITS 4,5,6 - Nominal Gross Cooling Capacity (MBh) 036 = 3 Ton 048 = 4 Ton 060 = 5 Ton 072 = 6 Ton 090 = 7.5 Ton, Single Compressor 092 = 7.5 Ton, Dual Compressors 102 = 8.5 Ton 120 = 10 Ton DIGIT 7 - Major Design Sequence A = First DIGIT 8 - Unit Voltage 3 = 208-230/60/3 4 = 460/60/3 W = 575/60/3 K = 380/60/3 DIGIT 9 - Unit Controls E = Electromechanical R = ReliaTel DIGIT 10 - Heating Capacity Note: Sequence may be any letter A through Z, or any digit 1 through 9. 0 = No Electric Heater B = 6 kw (3 phase) C = 9 kw (3 phase) E = 12 kw (3 phase) G = 18 kw (3 phase) J = 23 kw (3 phase) K = 27 kw (3 phase) N = 36 kw (3 phase) P = 54 kw (3 phase) Note: Applicable to Digit 1, Y models only. L = Low M = Medium H = High X = Low, Stainless Steel Heat Exchanger Y = Medium, Stainless Steel Heat Exchanger Z = High, Stainless Steel Heat Exchanger DIGIT 11 - Minor Design Sequence A = First Sequence DIGIT 12,13 - Service Sequence ** = Factory Assigned DIGIT 14 - Fresh Air Selection 0 = No Fresh Air A = Manual Outside Air Damper 0-50%e B = Motorized Outside Air Damper 0-50% C = Economizer, Dry Bulb 0-100% without Barometric Relief2 D = Economizer, Dry Bulb 0-100% with Barometric Relief2
A = Thermal Expansion Valve (TXV) B = Dehumidification (Hot Gas Reheat Coil)ri DIGIT 23 - Refrigeration Controls 0 = No Refrigeration Control 1 = High Pressure Control16 2 = Frostat5 3 = Crankcase Heatery 4 = High Pressure Control16 and Frostat5 5 = High Pressure Control16 and Crankcase Heatery 6 = Frostat5 and Crankcase Heater6y 7 = High Pressure Control,16 Frostat5 and Crankcase Heater6y DIGIT 24 - Smoke Detector 0 = No Smoke Detector A = Return Air Smoke Detector89 B = Supply Air Smoke Detector C = Supply and Return Air Smoke Detectors9
DIGIT 25 - Monitoring Controls1 0 = No Monitoring Control0 1 = Clogged Filter Switch0 2 = Fan Failure Switch0 3 = Discharge Air Sensing Tube0 4 = CompleteCoat Condenser Coil 4 = Clogged Filter Switch and Fan Fail Switch0 5 = CompleteCoat Condenser Coil with Hail Guard 5 = Clogged Filter Switch and Discharge Air Sensing Tube0 DIGIT 18 - Through the Base Provisions Models 6 = Fan Fail Switch and Discharge Air Sensing Tube0 Note: (Applicable to Digit 1, T or Y models) 7 = Clogged Filter and Fan Fail Switches 0 = No Through the Base Provisions and Discharge Air Sensing Tube0 A = Through the Base Electrict 8 = Novar Return Air Sensorq Note: (Applicable to Digit 1, Y models only) Model Number Notes B = Through the Base Gas Piping 1 Not available with electromechanical unit controls. C = Through the Base Electric and Gas 2 Economizer with Barometric Relief is for downflow Pipingw configured units only. Order Economizer without DIGIT 19 - Disconnect/Circuit Breaker/ Phase Monitor (3 phase only) 0 = No Disconnect or Circuit Breaker 1 = Non-Fused Disconnectt 2 = Circuit Breakert 3 = Phase Monitor 4 = Phase Monitor & Non-Fused Disconnect Switch 5 = Phase Monitor & Circuit Breaker DIGIT 20 - Convenience Outlet 0 = No Convenience Outlet A = Unpowered Convenience Outlet B = Powered Convenience Outlet (3 phase only)3 DIGIT 21 - Communications Options1 0 = No Communications Interface 1 = Trane Communications Intertace 2 = LonTalk Communications Interface 3 = Novar 2024 Controls 4 = Novar 3051 Controls DIGIT 22 - Refrigeration System Option 0 = Standard Refrigeration System4
3 4 5 6 7 8 9 0 q w e r t y u i o
Barometric Relief for horizontal configuration. Barometric Relief for horizontal configured units must be ordered as field installed accessory. Requires use of Disconnect or Circuit Breaker. Standard refrigeration metering device short orifice. Frostat cannot be field installed in electro-mechanical units. High Pressure control is standard on 3-phase units with scrol compressors and in 3 ton standard efficiency units. Not available with High Temperature Stat accessory. The return air smoke detector may not fit up or work properly on the Precedent units when used in conjunction with 3rd party accessories such as bolt on heat wheels, economizers and power exhaust. Do not order the return air smoke detectors when using this type of accessory. Return Air Smoke Detector cannot be ordered with Novar Controls. These options are standard when ordering Novar Controls. This option is used when ordering Novar Controls. Includes gas piping and shutoff (field assembly required). The manual outside air damper will ship factory supplied within the unit, but must be field installed. Requires selection of 2 Pleated Filters (option B or C) for Digit 16. Through the base electric required when ordering disconnect/circuit breaker options. Crankcase heaters are standard on 3 ton standard efficiency and 7.5 ton single compressor units. Direct Drive (3-5 tons); Belt Drive (6-10 tons) Not available on 6 ton units and all single phase or standard efficiency. Available on 6-10 tons only.
PC 15
Mfg. Plant LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH
Shipping Weight 463 475 503 768 841 843 922 996 399 424 443 768 841 843 922 996 399 424 443 768 841 843 922 996
PC 16
Mfg. Plant LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH
Shipping Weight 480 522 560 805 944 980 1069 412 458 509 805 944 980 1069 412 458 509 805 944 980 1069
PC 17
PC 18
1 2 3 4
Not available with electro-mechanical unit controls. Economizer with Barometric Relief is for downflow configured units only. Order Economizer without Barometric Relief for horizontal configuration. Barometric relief for horizontal configured units must be ordered as field installed accessory BAYBARM010A. Barometric Relief cannot be used with Power Exhaust. The Manual Outside Air Damper will ship factory supplied (field installed) within the unit. The option will no longer be factory installed.
1 Available for 3 phase 3-5 ton models only. 2 3-5 ton standard motor is direct drive. 6-10 ton standard motor is belt drive. 3 3-5 ton oversized motor is direct drive. 6-10 ton oversized motor is belt drive.
PC 19
PC 20
1 Disconnect/Circuit Breaker/Phase Monitor is available for 3 phase models only. 2 Must order Through the Base option when ordering disconnect or Breaker. 3 Phase Monitor is available with ReliaTel models only. 4 Phase monitor will be standard on T_C060A3,4,W (three phase).
Table 11 Convenience Outlet (Digit 20)
Tons 3 4 5 6 7.5 8.5 10 Unpowered Convenience Outlet (A) Powered 12 Convenience Outlet (B)
1 2
Powered Convenience Outlet Option is available for 3 phase models only. Requires use of Disconnect or Circuit Breaker.
PC 21
N/A
1 2 3 4 5 6
Standard Refrigeration Metering Device - Short Orifice. Not available on standard efficiency models, single phase units or with electromechanical controls. Crankcase heaters, TXV's, Frostat, high and low pressure switches, face-split evaporator coil and 2" pleated filters standard with this option. Belt drive standard. Do not select Digit 15=2 (Optional Belt Drive Motor). Not available on heat pumps. Requires selection of 2" Pleated Filters (Option B or C) under Digit 16.
1 2 3
Not available with Electro-Mechanical Controls. Frostat cannot be field installed in electro mechanical units. Crankcase Heater is standard in TSC036A and TSC090A.
High Pressure Control is standard on all three-phase models. High pressure control is a selectable item on the following models: 4 and 5 ton single-phase (standard and high efficiency) and 3 ton high efficiency single-phase.
PC 22
1 Not available with Electro-Mechanical Controls. 2 Not available with BAYFRST001A High Temperature Stat accessory. 3 The return air smoke detector may not fit up or work properly on the Precedent units when used in conjunction with 3rd party accessories (such as bolt on heat wheels, economizers, and power exhaust). Do not order the return air smoke detectors when using this type of accessory. 4 Return Air Smoke Detector cannot be ordered with Novar Controls.
Table 16 Monitoring Controls (Digit 25) 1
Tons 3 4 5 6 7.5 8.5 10 Clogged Filter Switch2 (1) Fan Failure Switch2 (2) Discharge Air Sensing Tube2 (3) Clogged Filter Switch and Fan Fail Switch2 (4)
Clogged Filter and Fan Fail Switches and Discharge Air Sensing Tube24 (7)
1 Not available with Electro-Mechanical Controls. 2 These options are standard when ordering Novar Controls. 3 This option for use when ordering Novar Control only.
4 Combination of Discharge Air Sensing option, Economizer option and Tracer Summit or
Tracker, Version 10 requires use of Tracer LCI-R Communications Interface. For jobs requiring true discharge air sensing with Tracer/Tracker COMM-3 or COMM-4, contact Clarksville Light Commercial Marketing Support.
PC 23
Accessory Electric Heaters: Unit with heater is single circuit / single point power entry
Model Number BAYHTRR306A BAYHTRR312A BAYHTRR318A BAYHTRR323A Power Supply 208/240/60/3 208/240/60/3 208/240/60/3 KW Rating 4.5/6.0 9.0/12.0 13.1/17.4 Nominal No. of BTUH Stages 13,400/ 1 20,500 30,800/ 2 41,000 44,600/ 2 59,400 58,900/ 2 78,500 20,500 41,000 59,400 78,500 20,500 41,000 59,400 78,500 1 2 2 2 1 2 2 2 Used With T*C036-060A3 T*C036-060A3 T*C036-060A3 T*C060A3 Mfg. Plant SH SH SH SH Shipping Weight 20 20 20 20
208/240/60/30 17.3/23.0
SH SH SH SH SH SH SH SH
20 20 20 20 20 20 20 20
PC 24
Accessory Electric Heaters: Unit with heater is single circuit / single point power entry
Model Number BAYHTRS309A BAYHTRT309A BAYHTRS318A BAYHTRT318A BAYHTRS327A BAYHTRT327A BAYHTRS336A BAYHTRT336A BAYHTRT354A Power Supply 208/240/60/3 208/240/60/3 208/240/60/3 208/240/60/3 208/240/60/3 208/240/60/3 208/240/60/3 208/240/60/3 208/240/60/3 KW Rating 6.75/9.0 6.75/9.0 13.5/18.0 13.5/18.0 20.3/27.0 20.3/27.0 27.0/36.0 27.0/36.0 40.5/54.0 Nominal No. of BTUH Stages 23,000/ 1 30,700 23,000/ 1 30,700 46,100/ 1 61,400 46,100/ 1 61,400 69,000/ 2 92,100 69,000/ 2 92,100 92,200/ 2 122,900 92,200/ 2 122,900 138,200/ 2 184,300 30,700 30,700 61,400 61,400 92,100 92,100 122,900 122,900 184,300 30,700 61,400 61,400 92,100 92,100 122,900 122,900 184,300 1 1 1 1 2 2 2 2 2 1 1 1 2 2 2 2 2 Used With T*C072A3 TSC090,092A3 THC092A3, T*C102A3 T*C072A3 TSC090,092A3 THC092A3 T*C102,120A3 T*C072A3 TSC090,092A3 T*C102,120A3 THC092A T*C072A3 TSC090,092A3 THC092A3 T*C102,120A3 T*C120A3 Mfg. Plant SH SH SH SH SH SH SH SH SH Shipping Weight 26 26 28 28 26 26 31 31 38
BAYHTRS409A BAYHTRT409A BAYHTRS418A BAYHTRT418A BAYHTRS427A BAYHTRT427A BAYHTRS436A BAYHTRT436A BAYHTRT454A BAYHTRSW09A BAYHTRSW18A BAYHTRTW18A BAYHTRSW27A BAYHTRTW27A BAYHTRSW36A BAYHTRTW36A BAYHTRTW54A
460/60/3 460/60/3 460/60/3 460/60/3 460/60/3 460/60/3 460/60/3 460/60/3 460/60/3 575/60/3 575/60/3 575/60/3 575/60/3 575/60/3 575/60/3 575/60/3 575/60/3
9.0 9.0 18.0 18.0 27.0 27.0 36.0 36.0 54.0 9.0 18.0 18.0 27.0 27.0 36.0 60 54.0
T*C072A4, TSC090,092A4 THC092A4, T*C102A4 T*C072A4, TSC090,092A4 THC092A4, T*C102,120A4 T*C072A4, TSC090,092A4 THC092A4, T*C102,120A4 T*C072A4, TSC090,092A4 THC092A4, T*C102-120A4 T*C120A4 T*C072AW, TSC090,092AW T*C072AW TSC090,092AW THC092AW T*C102,120AW T*C072AW, TSC090,092AW THC092AW, T*C102,120AW T*C072AW TSC090,092AW THC092AW T*C102,120AW T*C120AW
SH SH SH SH SH SH SH SH SH SH SH SH SH SH SH SH SH
26 26 28 28 26 26 31 31 38 26 28 28 26 26 31 31 38
PC 25
1 2 3 4 5 6
*
Lynn Haven Manufacturing has a No-Return policy for this roof curb. For use with ReliaTelTM controlled units only BAYQACB009A adapts Voyager BAYCURB021B to accept Precedent 3-5 ton unit. BAYQACB010A adapts Voyager BAYCURB022B to accept Precedent 3-5 unit. For use with electromechanical controlled units only. BAYQACB011A adapts Voyager BAYCURB022 to accept Precedent 6-10 ton unit. BAYQACB012A adapts Voyager BAYCURB025B to accept Precedent 6-10 ton unit. BAYQACB013A adapts Voyager BAYCURB026B to accept Precedent 6-10 ton unit. TCD036A, TCD048A, TCD060A, WCD036A, WCD048A, WCD060A are not Voyager units. These units were manufactured in Ft. Smith, AR and will not fit any Voyager curbs. Either standard or high efficiency models
PC 26
Description
Used With
See Note T*C036-060A T*C072-120A T*C072-120A3 T*C072-120A4 T*C072-120AW T*C036-120A*R W/Econ. or Motorized OA Damper T*C036-120A*R W/Econ. or Motorized OA Damper THC036-072A3 TSC048-072A3 T*C092-120A3 THC036-072A4,AW TSC048-072A4,AW T*C092-120A4,AW T*C090A3 T*C090A4 T*C090AW BAYECON085A,087A T*C036-120A_R T*C036-120A_R T*C036-120A_R BAYECON085A,087A BAYECON085A,087A BAYECON0086A,088A T*C036-120A_R T*C036-120A_R T*C036-060A_R T*C072-120A_R T*C036-120A_R T*C036-120A_R T*C036-120A_E T*C036-120A_R THC036A3,4,WR THC048A3,4,WR THC060A3,4,WR THC092-102A3,4,WR THC120A3,4,WR T*C036-120A*R W/ReliaTel Options Module
5 5 q q qw
ReliaTel Options Module Barometric Relief Barometric Relief Power Exhaust Power Exhaust Power Exhaust CO2 Sensor Kit, Wall Mounted CO2 Sensor Kit, Duct Mounted
w w
Crankcase Heater
BAYCCHT011B
Crankcase Heater
LH
BAYCCHT012A BAYCCHT013A BAYCCHT014A BAYSTAT023 BAYSERV001A BAYSENS016A BAYFRST001A BAYENTH005A BAYENTH006B BAYENTH001A BAYDFPS003B BAYDFPS004A BAYTUBE005A BAYTUBE007A BAYICSI003A
4 4 4 48 14 14 47 47 347 347 49 BAYLTCI002B40 BAYASCT001 8 BAYLOAM020B247 BAYLSDR006Ae BAYLSDR007Ae BAYLSDR008Ae BAYLSDR009Ae BAYLSDR010Ae BAYVNOR001Be
TM
Crankcase Heater Crankcase Heater Crankcase Heater Remote Potentiometer Selective Resistance Service Tester Temperature Sensor High Temperature Stat Reference Enthalpy Kit Comparative Enthalpy Kit Enthalpy Control (Solid State) Clogged Filter Switch Fan Failure Switch Discharge Air Sensing Kit Discharge Air Sensing Kit Comm-3/4 Trane Communications Interface Comm-3/4 LonTalk Communications Interface Anti-Short-Cycle Timer Evaporator Defrost Control (Frostat) Low Static Drive Kit Low Static Drive Kit Low Static Drive Kit Low Static Drive Kit Low Static Drive Kit Ventilation Override Kit
2 2 2 1 2 1 2 1 1 2 1 1 1 1 1 1 1 2 2 2 2 2 2.5
1 Kits contain all necessary parts to achieve desired level of enthalpy control. 2 For ReliaTel microprocessor controlled units only. 3 4 5 6
Must be factory installed for electromechanical controlled units Used for true discharge air sensing in both heating and cooling.Required for supply air tempering. For use with ReliaTel TM controlled units only Barometric Relief accessory installs in ductwork for horizontal configuration. For downflow configuration, installs in the unit's horizontal return duct. See Installer's Guide for complete instructions. Cannot be used in conjunction with factory installed smoke detector.
8 9
installed accessories Clogged Filter Switch (BAYDFPS003A), Fan Fail Switch (BAYDFPS004A), Discharge Air Sensing Kit (BAYTUBE004A) or Evaporator Defrost Control (Frostat) (BAYLOAM020B) unless the following options are factory installed: Frostat, Smoke Detector, Clogged Filter Switch, Fan Failure Switch, Discharge Air Sensing Kit. These factory installed options include the ReliaTelTM Options Module. For use with electromechanical controlled units only. Interface allows a unit with ReliaTelTM Controls to communicates with Tracer 100, Tracker, VariTrac II, and is the preferred method of communication to Tracer Summit.
q w e
TM Controls to communicate as a Trane LonTalk device or directly with generic LonTalk Network BAS Controls. Cannot be used in conjunction with Barometric Relief. Order Economizer without Barometric Relief. Quantity 2 required for T*C092-120A Available for Cooling Units only
PC 27
Used with T*C036-120A_R T*C036-120A_R T*C036-120A_R T*C036-120A_R T*C036-120A_R T*C036-120A_R BAYSENS006B,008B, 010B, & 019C T*C036-120A_R T*C036-120A_R THC036-120A_R THC036-120A_R BAYSENS019C BAYSENS006,008 010B,013,014C,017B
1 Used with Integrated Comfort Systems, any unit type. These sensors do not work with TCM. Consult BASD Marketing for them. 2 See Accessory IOM for operational characteristics. 3 Functional only with ReliaTel controls.
* Either standard or high efficiency models
Thermostats:
Model Number BAYSTAT040A24 BAYBASE008A BAYBASE006A BAYSENS033A BAYSENS034A TCONT200AN11AA BAY28X1903 BAY24X042 BAYSTAT050A BAYSTAT051A BAYSTAT052A BAYSTAT053A Description Programmable Thermostat Subbase 1-Stage Htg./Clg. Subbase 2-Stage Htg./Clg. Remote Wall Sensor Remote Duct Sensor Electronic, 1Htg/1Clg (Non Prog.) Locking Thermostat Cover for up to 4 units DPDT Fan and Electric Heat Relay 2Htg/2Clg Digital Display Programmable Thermostat 1Htg/1Clg Digital Display Thermostat 2Htg/2Clg Digital Display Programmable "TOUCHSCREEN" Thermostat 3Htg/2Clg Digital Display Programmable Thermostat with Relative Humidity Sensing Built-In 3Htg/2Clg Digital Display Thermostat Return Air Remote Sensor Wall Mounted Remote Sensor Used with T*C036-120A BAYSTAT040A BAYSTAT040A BAYSTAT040A BAYSTAT040A All Cooling/(Gas or Elec) Room Thermostats BAYSTAT051,052 T*C036-120A T*C036-060A T*C036-120A Mfg. Shipping Plant Weight CK/001 1 CK/001 1 CK/001 1 CK/001 1 CK/001 1 TY 1 TY 1 TY 1 CK/001 1 CK/001 CK/001 1 1 1
T*C036-120A CK/001 (with Dehumidification Option) T*C036-120A BAYSTAT050A,051A, 052A,053A BAYSTAT050A,051A, 052A,053A CK/001 CK/001 CK/001
1 1 1
1 Requires DPDT Fan and Electric Heat Relay BAY24x042 when using electric heat. 2 Requires use of subbase BAYBASE006A or BAYBASE008A. 3 Do not use with programmable thermostats. 4 Thermostat does not include fan or system switches.
PC 28
Model Nomenclature
T 1
H 2
C 033 A 3 4,5,6 7
3 8
R B A ** C 0 0 0 A 1 9 10 11 12,13 14 15 16 17 18 19
DIGIT 15 - Supply Fan/Drive Type/Motor 0 = Standard Drive DIGIT 16 - Hinged Service Access & Filters 0 = Standard Panels & Filters A = Hinged Access Panels & Standard Filters B = Standard Panels & 2" Pleated Filters C = Hinged Access Panels & 2" Pleated Filters DIGIT 17 - Condenser Coil Protection 0 = Standard Coil 1 = Standard Coil with Hail Guard 2 = Epoxy Coated Condenser Coil 3 = Epoxy Coated Condenser Coil with Hail Guard 4 = CompleteCoat Condenser Coil 5 = CompleteCoat Condenser Coil with Hail Guard DIGIT 18 - Through the Base Provisions 0 = No Through the Base Provisions A = Through the Base Electric DIGIT 19 - Disconnect/Circuit Breaker Phase Monitor (3 phase only) 0 = No Disconnect, Circuit Breaker or Phase Monitor 1 = Unit Mounted Non-Fused Disconnect 2 = Unit Mounted Circuit Breaker 3 = Phase Monitor 4 = Phase Monitor and Non-Fused Disconnect Switch 5 = Phase Monitor and Circuit Breaker DIGIT 20 - Convenience Outlet 0 = No Convenience Outlet A = Unpowered Convenience Outlet B = Powered Convenience Outlet (3 phase only) DIGIT 21 - Communications Options 0 = No Communications Interface 1 = Comm-3/4 Trane Communications Interface 2 = LonTalk Communications Interface 3 = Novar 2024 Controls 4 = Novar 3051 Controls DIGIT 22 - Refrigeration System Option 0 = Standard Refrigeration System B = Dehumidification (Hot Gas Reheat Coil)
DIGIT 1 - Unit Function T = DX Cooling DIGIT 2 - Efficiency H = High Efficiency DIGIT 3 - Airflow C = Convertible DIGITS 4,5,6 - Nominal Gross Cooling Capacity (MBh) 033 = 3 Ton 043 = 4 Ton 063 = 5 Ton DIGIT 7 - Major Design Sequence A = R-22 Refrigerant DIGIT 8 - Unit Voltage 3 = 208-230/60/3 4 = 460/60/3 W = 575/60/3 DIGIT 9 - Unit Controls E = Electro-Mechanical R = ReliaTelMicro-processor DIGIT 10 - Electric Heater 0 = No Electric Heater B = 6 kW (3 phase) C = 9 kW (3 phase) E = 12 kW (3 phase) G = 18 kW (1 and 3 phase) J = 23 kW (3 phase) DIGIT 11 - Minor Design Sequence A = First Sequence DIGIT 12,13 - Service Sequence ** = Factory Assigned DIGIT 14 - Fresh Air Selection 0 = No Fresh Air A = Manual Outside Air Damper 0-50% B = Motorized Outside Air Damper 0-50% C = Economizer, Dry Bulb 0-100% without Barometric Relief D = Economizer, Dry Bulb 0-100% with Barometric Relief E = Economizer, Reference Enthalpy 0-100% without Barometric Relief F = Economizer, Reference Enthalpy 0-100% with Barometric Relief G = Economizer, Comparative Enthalpy 0-100% without Barometric Relief H = Economizer, Comparative Enthalpy 0-100% with Barometric Relief
DIGIT 23 - Refrigeration Controls 0 = No Refrigeration Control 1 = High Pressure Control 2 = Frostat 3 = Crankcase Heater 4 = High Pressure Control and Frostat 5 = High Pressure Control and Crankcase Heater 6 = Frostat and Crankcase Heater 7 = High Pressure Control, Frostat and Crankcase Heater DIGIT 24 - Smoke Detector 0 = No Smoke Detector A = Return Air Smoke Detector B = Supply Air Smoke Detector C = Supply and Return Air Smoke Detectors DIGIT 25 - Monitoring Controls 0 = No Monitoring Control 1 = Clogged Filter Switch 2 = Fan Failure Switch 3 = Discharge Air Sensing Tube 4 = Clogged Filter Switch and Fan Fail Switch 5 = Clogged Filter Switch and Discharge Air Sensing Tube 6 = Fan Fail Switch and Discharge Air Sensing Tube 7 = Clogged Filter and Fan Fail Switches and Discharge Air Sensing Tube 8 = Novar Return Air Sensor
Example: Model number THC033A3RBA**C000A10001A10 describes a unit with the following characteristics: DX Cooling , 3 ton nominal cooling capacity, 208-230/60/3 power supply, ReliaTel controls, 6 kW electric heater model. 0-100% dry bulb economizer without barometric relief, standard belt drive motor, standard access panels and filters, standard condenser coil with no coil protection, through the base electric, non-fused disconnect, no convenience outlet or communications interface, standard refrigeration coil, high pressure control, return air smoke detector, and clogged filter switch.
PC 29
Mfg. Plant LH LH LH LH LH LH LH LH LH
Shipping Weight 549 591 641 549 591 641 549 591 641
PC 30
Tons 3 4 5
Tons 3 4 5
1 2 3 4
Not available with electro-mechanical unit controls. Economizer with Barometric Relief is for downflow configured units only. Order Economizer without Barometric Relief for horizontal configuration. Barometric relief for horizontal configured units must be ordered as field installed accessory BAYBARM010A. Barometric Relief cannot be used with Power Exhaust. The Manual Outside Air Damper will ship factory supplied (field installed) within the unit. The option will no longer be factory installed.
PC 31
1 Disconnect/Circuit Breaker/Phase Monitor is available for 3 phase models only. 2 Must order Through the Base option when ordering disconnect or Breaker. 3 Phase Monitor is available with ReliaTel models only.
Table 10 Convenience Outlet (Digit 20)
Tons 3 4 5 Unpowered Convenience Outlet (A) Powered 12 Convenience Outlet (B)
1 2
Powered Convenience Outlet Option is available for 3 phase models only. Requires use of Disconnect or Circuit Breaker.
1 2 3 4 5 6
Standard Refrigeration Metering Device - TXV. Not available on standard efficiency models, single phase units or with electromechanical controls. Crankcase heaters, TXV's, Frostat, high and low pressure switches, face-split evaporator coil and 2" pleated filters standard with this option. Belt drive standard. Do not select Digit 15=2 (Optional Belt Drive Motor). Not available on heat pumps. Requires selection of 2" Pleated Filters (Option B or C) under Digit 16.
PC 32
1 2 3
Not available with Electro-Mechanical Controls. Frostat cannot be field installed in electro mechanical units. High Pressure Control is standard on all three-phase models.
1 Not available with Electro-Mechanical Controls. 2 Not available with BAYFRST001A High Temperature Stat accessory. 3 The return air smoke detector may not fit up or work properly on the Precedent units when used in conjunction with 3rd party accessories (such as bolt on heat wheels, economizers, and power exhaust). Do not order the return air smoke detectors when using this type of accessory. 4 Return Air Smoke Detector cannot be ordered with Novar Controls.
Table 15 Monitoring Controls (Digit 25) 1
Tons 3 4 5 Clogged Filter Switch2 (1) Fan Failure Switch2 (2) Discharge Air Sensing Tube2 (3) Clogged Filter Switch and Fan Fail Switch2 (4)
Clogged Filter and Fan Fail Switches and Discharge Air Sensing Tube24 (7)
1 Not available with Electro-Mechanical Controls. 2 These options are standard when ordering Novar Controls. 3 This option for use when ordering Novar Control only. 4 Combination of Discharge Air Sensing option, Economizer option and Tracer Summit or Tracker, Version 10 requires use of Tracer LCI-R Communications Interface. For
jobs requiring true discharge air sensing with Tracer/Tracker COMM-3 or COMM-4, contact Clarksville Light Commercial Marketing Support.
PC 33
Accessory Electric Heaters: Unit with heater is single circuit / single point power entry
Model Number BAYHTRR306A BAYHTRR312A BAYHTRR318A BAYHTRR323A Power Supply 208/240/60/3 208/240/60/3 208/240/60/3 208/240/60/3 KW Rating 4.5/6.0 9.0/12.0 13.1/17.4 17.3/23.0 Nominal No. of BTUH Stages 13,400/ 1 20,500 30,800/ 2 41,000 44,600/ 2 59,400 58,900/ 2 78,500 20,500 41,000 59,400 78,500 20,500 41,000 59,400 78,500 1 2 2 2 1 2 2 2 Used With THC033-063A3 THC033-063A3 THC033-063A3 THC063A3
SH SH SH SH SH SH SH SH
20 20 20 20 20 20 20 20
PC 34
Description Roof Curb Quick Adapt Roof Curb Quick Adapt Roof Curb 0-100% Dry BulbEconomizer without Barometric Relief 0-100% Dry Bulb Economizer without Barometric Relief 0-50% Motorized Outside Air Damper 0-50% Motorized Outside Air Damper 0-50% Manual Outside Air Damper Tool-less Condenser Coil Hail Guard Tool-less Condenser Coil Hail Guard
ReliaTel Options Module Barometric Relief CO2 Sensor Kit, Wall Mounted CO2 Sensor Kit, Duct Mounted Crankcase Heater Crankcase Heater Remote Potentiometer Selective Resistance Service Tester Temperature Sensor High Temperature Stat Reference Enthalpy Kit Comparative Enthalpy Kit Enthalpy Control (Solid State) Clogged Filter Switch Fan Failure Switch Discharge Air Sensing Kit Comm-3/4 Trane Communications Interface Comm-3/4 LonTalk Communications Interface Anti-Short-Cycle Timer Evaporator Defrost Control (Frostat) Low Static Drive Kit Low Static Drive Kit Low Static Drive Kit Ventilation Override Kit
Used With THC033-063A THC033-063A THC033-063A THC033-063A_R THC033-063A_E THC033-063A_R THC033-063A_E THC033-063A THC033, 043A THC063A
See Note THC033-063A THC033-063A_R W/Econ. THC033-063A_R W/Econ. THC033-063A, A3 THC033-063A4,AW BAYECON085A,087A THC033-063A_R THC033-063A_R THC033-063A_R BAYECON085A,087A BAYECON085A,087A BAYECON0086A,088A THC033-063A_R THC033-063A_R THC033-063A_R THC033-063A_R THC033-063A_R
Lynn Haven Manufacturing has a No-Return policy for this roof curb. For use with ReliaTelTM controlled units only For use with electromechanical controlled units only. Kits contain all necessary parts to achieve desired level of enthalpy control. For ReliaTelTM microprocessor controlled units only. Must be factory installed for electromechanical controlled units Used for true discharge air sensing in both heating and cooling.Required for supply air tempering. Barometric Relief accessory installs in ductwork for horizontal configuration. For downflow configuration, installs in the unit's horizontal return duct. See Installer's Guide for complete instructions.
THC033-063A_E CK/001 THC033-063A_R LH THC033A, 3, 4, WR LH THC043A, 3, 4, WR LH THC063A, 3, 4, WR LH THC033-063A*R LH W/ReliaTel Options Module
BAYABRD001C is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS003A), Fan Fail Switch (BAYDFPS004A), Discharge Air Sensing Kit (BAYTUBE004A) or Evaporator Defrost Control (Frostat) (BAYLOAM020B) unless the following options are factory installed: Frostat, Smoke Detector, Clogged Filter Switch, Fan Failure Switch, Discharge Air Sensing Kit. These factory installed options include the ReliaTelTM Options Module. Interface allows a unit with ReliaTelTM Controls to communicates with Tracer 100, Tracker, VariTrac II, and is the preferred method of communication to Tracer Summit.
Interface allows a unit with ReliaTelTM Controls to communicate as a Trane LonTalk device or directly with generic LonTalk Network BAS Controls. Available for Cooling Units only
PC 35
1 Used with Integrated ComforT Systems, any unit type. These sensors do not work with TCM. Consult BASD Marketing for them. 2 See Accessory IOM for operational characteristics. 3 Functional only with ReliaTel controls.
* Either standard or high efficiency models
BAYSENS006B,008B, 010B, & 019C Dual Thermistor Remote Zone Sensor THC033-063A_R Digital Display Zone Sensor THC033-063A_R Wall-Mounted Humidity Zone Sensor THC033-063A_R Duct-Mounted Humidity Zone Sensor THC033-063A_R Retrofit Wall Cover Plate Kit BAYSENS019C 7.25" x 6.0" Retrofit Wall Cover Plate Kit BAYSENS006,008 4.75" x 4.75" 010B,013,014C,017B
Thermostats:
Model Number Description BAYSTAT040A24 Programmable Thermostat BAYBASE008A Subbase 1-Stage Htg./Clg. BAYBASE006A Subbase 2-Stage Htg./Clg. BAYSENS033A Remote Wall Sensor BAYSENS034A Remote Duct Sensor TCONT200AN11AAElectronic, 1Htg/1Clg (Non Prog.) BAY28X1903 Locking Thermostat Cover for up to 4 units BAY24X042 DPDT Fan and Electric Heat Relay BAYSTAT050A 2Htg/2Clg Digital Display Programmable Thermostat BAYSTAT051A 1Htg/1Clg Digital Display Thermostat BAYSTAT052A 2Htg/2Clg Digital Display Programmable "TOUCHSCREEN" Thermostat BAYSTAT053A 3Htg/2Clg Digital Display Programmable Thermostat with Relative Humidity Sensing Built-In BAYSTAT055A 3Htg/2Clg Digital Display Thermostat BAYSTAT059A Return Air Remote Sensor BAYSTAT060A Wall Mounted Remote Sensor Used with THC033-063A BAYSTAT040A BAYSTAT040A BAYSTAT040A BAYSTAT040A All Cooling/(Gas or Elec) Room Thermostats BAYSTAT051,052 THC033-063A_R THC033-063A_R THC033-063A_R Mfg. Shipping Plant Weight CK/001 1 CK/001 1 CK/001 1 CK/001 1 CK/001 1 TY 1 TY 1 TY 1 CK/001 1 CK/001 CK/001 1 1 1
THC033-063A_R CK/001 (with Dehumidification Option) THC033-063A_R BAYSTAT050A,051A, 052A,053A BAYSTAT050A,051A, 052A,053A CK/001 CK/001 CK/001
1 1 1
1 Requires DPDT Fan and Electric Heat Relay BAY24x042 when using electric heat. 2 Requires use of subbase BAYBASE006A or BAYBASE008A. 3 Do not use with programmable thermostats. 4 Thermostat does not include fan or system switches.
PC 36
Model Nomenclature
T 1
S 2
C 036 E 3 4,5,6 7
3 8
R B 9 10
A ** C 0 0 0 11 12,13 14 15 16 17
A 1 18 19
1 23
A 24
1 25
DIGIT 1 - Unit Function T = DX Cooling DIGIT 2 - Efficiency S = Standard Efficiency (13 SEER R-410A) DIGIT 3 -Airflow C = Convertible DIGITS 4,5,6 - Nominal Gross Cooling Capacity (MBh) 036 = 3 Ton 046 = 4 Ton 060 = 5 Ton DIGIT 7 - Major Design Sequence E = R-410A Refrigerant DIGIT 8 - Unit Voltage 1 = 208-230/60/1 3 = 208-230/60/3 4 = 460/60/3 W = 575/60/3 DIGIT 9 - Unit Controls E = Electromechanical1 R = ReliaTelMicroprocessor DIGIT 10 - Heating Capacity Note: (Applicable to Digit 1, W models only) 0 = No Electric Heat A = 5 kW (1 phase)2 B = 6 kW (3 phase) C = 9 kW (3 phase)4 D = 10 kW (1 phase)2 E = 12 kW (3 phase) F = 14 kW (1 phase)2 G = 18 kW (1&3phase) J = 23 kW (3 phase) DIGIT 11 - Minor Design Sequence A = First Sequence DIGITS 12, 13 - Service Sequence ** = Factory Assigned DIGIT 14 - Fresh Air Selection 0 = No Fresh Air A = Manual Outside Air Damper 0-50%6 B = Motorized Outside Air Damper 0-50% C = Economizer, Dry Bulb 0-100% without Barometric Relief0 D = Economizer, Dry Bulb 0-100% with Barometric Relief0 E = Economizer, Reference Enthalpy 0-100% without Barometric Relief50 F = Economizer, Reference Enthalpy 0-100% with Barometric Relief50 G = Economizer, Comparative Enthalpy 0-100% without Barometric Relief50 H = Economizer, Comparative Enthalpy 0-100% with Barometric Relief50
DIGIT 15 - Supply Fan/Drive Type/Motor 0 = Standard Drive8 DIGIT 16 - Hinged Service Access/Filters 0 = Standard Panels/Standard Filters A = Hinged Access Panels/Standard Filters B = Standard Panels/2 Pleated Filters C = Hinged Access Panels/2 Pleated Filters DIGIT 17 - Condenser Coil Protection 0 = Standard Coil 1 = Standard Coil with Hail Guard 2 = Epoxy Coated Condenser Coil 3 = Epoxy Coated Condenser Coil with Hail Guard
24 - Smoke Detector5o No Smoke Detector Return Air Smoke Detectorty Supply Air Smoke Detector Supply and Return Air Smoke Detectorsty
DIGIT 18 - Through the Base Provisions Note: (Applicable to Digit 1, T models only) 0 = No Through the Base Provisions A = Through the Base Electricq DIGIT 19 - Disconnect/Circuit Breaker/ Phase Monitor (3 phase only) 0 = No Disconnect/No Circuit Breaker/No Phase Monitor 1 = Unit Mounted Non-Fused Disconnectq 2 = Unit Mounted Circuit Breakerq 3 = Phase Monitor 4 = Phase Monitor & Non-Fused Disconnect Switch 5 = Phase Monitor & Circuit Breaker DIGIT 20 - Convenience Outlet 0 = No Convenience Outlet A = Unpowered Convenience Outlet B = Powered Convenience Outlet (3 phase only)w DIGIT 21 - Communications Options4 0 = No Communications Interface 1 = Trane Communications Interface 2 = LonTalk Communications Interface 3 = Novar 2024 Controls1 4 = Novar 3051 Controls1 DIGIT 22 - Refrigeration System Option 0 = Standard Refrigeration Coile B = Dehumidification (Hot Gas Reheat Coil)149 DIGIT 23 - Refrigeration Controls 0 = No Refrigeration Control7 1 = Frostatr 2 = Crankcase Heater3 3 = Frostatr and Crankcase Heater
DIGIT 25 - Monitoring Controls5 0 = No Monitoring Controlu 1 = Clogged Filter Switchu 2 = Fan Failure Switchu 3 = Discharge Air Sensing Tubeu 4 = Clogged Filter Switch and Fan Fail Switchu 5 = Clogged Filter Switch and Discharge Air Sensing Tubeu 6 = Fan Fail Switch and Discharge Air Sensing Tubeu 7 = Clogged Filter and Fan Fail Switches and Discharge Air Sensing Tubeu 8 = Novar Return Air Sensori
Explanation of Model Number Notes 1-19 follow. Unless otherwise noted, feature available for all T models, tonnages and phases.
1 Not available for 3-5 ton, R-410A Heat Pumps. 2 Available for R-410A units only. 3 Standard on 4 ton , 3 phase Heat Pumps and 5 ton Heat Pumps. 4 Available for R-22 units only. 5 Not available with electromechanical controls. 6 Manual outside air damper will ship factory supplied within the unit, but must be field installed. 7 High pressure control is standard on all units. 8 Multispeed direct drive standard on 1 phase. Belt drive standard on 3 phase. 9 Requires selection of 2 pleated filters 0 Economizer with Barometric Relief is for downflow q w e r t y u i o
configured units only. Order Economizer without Barometric Relief for horizontal configuration. Barometric Relief for horizontal configured units must be ordered as field installed accessory. Through the base electric required when ordering disconnect/circuit breaker options. Requires use of Disconnect or Circuit Breaker. Standard metering devices are TXVs. Frostat cannot be field installed in electro-mechanical units. The return air smoke detector may not fit up or work properly on the Precedent units when used in conjunction with 3rd party accessories such as bolt on heat wheels, economizers and power exhaust. Do not order the return air smoke detectors when using this type of accessory. Return air smoke detector cannot be ordered with Novar Controls. These options are standard when ordering Novar Controls. This option is used when ordering Novar Controls. Not available with high temperature stat accessory.
Example: Model number TSC036E3RBA**C000A10001A1 describes a unit with the following characteristics: DX Cooling, 3 ton nominal cooling capacity, 208-230/60/3 power supply, ReliaTel controls, 6 kW electric heater model. 0-100% dry bulb economizer without barometric relief, standard belt drive motor, standard access panels/filters, standard condenser coil with no coil protection, through the base electric, non-fused disconnect, no convenience outlet or communications interface, standard refrigeration coil, high pressure control, return air smoke detector, and clogged filter switch.
PC 37
SEER 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0
PC 38
Tons 3 4 5
1 Not available with electro-mechanical unit controls. 2 Economizer with Barometric Relief is for downflow configured units only. Order Economizer without Barometric Relief for horizontal configuration. Barometric relief for horizontal configured units must be ordered as field installed accessory BAYBARM010A. 3 Barometric Relief cannot be used with Power Exhaust. 4 The Manual Outside Air Damper will ship factory supplied (field installed) within the unit. The option will no longer be factory installed.
Table 5 Supply Fan Drive Type/Motor (Digit 15)
Tons 3 4 5 Standard1 Motor (0) $ Included $ Included $ Included
Tons 3 4 5
1 3-5 ton 1 phase standard motor direct drive, 3 phase belt drive.
Table 6 Hinged Service Access & Filters(Digit 16)
Tons 3 4 5 Standard Panels & Filters (0) $ Included $ Included $ Included Hinged Access Panels & Filters (A) Standard Panels & 2" Pleated Filters (B) Hinged Access Panels & 2" Pleated Filters (C)
PC 39
1 Disconnect/Circuit Breaker/Phase Monitor is available for 3 phase models only. 2 Must order Through the Base option when ordering disconnect or Breaker. 3 Phase Monitor is available with ReliaTel models only.
Table 10 Convenience Outlet (Digit 20)
Tons 3 4 5 Unpowered Convenience Outlet (A) Powered 12 Convenience Outlet (B)
1 2
Powered Convenience Outlet Option is available for 3 phase models only. Requires use of Disconnect or Circuit Breaker.
1 2
Standard Refrigeration Metering Device - Thermal Expansion Valve. Not available on standard efficiency models, single phase units or with electromechanical controls. Available on R-22 only.
PC 40
2 Not available with BAYFRST001A High Temperature Stat accessory. 3 The return air smoke detector may not fit up or work properly on the Precedent units when used in conjunction with 3rd party accessories (such as bolt on heat wheels, economizers, and power exhaust). Do not order the return air smoke detectors when using this type of accessory. 4 Return Air Smoke Detector cannot be ordered with Novar Controls.
Table 15 Monitoring Controls (Digit 25) 1
Tons 3 4 5 Clogged Filter Switch2 (1) Fan Failure Switch2 (2) Discharge Air Sensing Tube2 (3) Clogged Filter Switch and Fan Fail Switch2 (4)
Clogged Filter and Fan Fail Switches and Discharge Air Sensing Tube24 (7)
1 Not available with Electro-Mechanical Controls. 2 These options are standard when ordering Novar Controls. 3 This option for use when ordering Novar Control only. 4 Combination of Discharge Air Sensing option, Economizer option and Tracer Summit or Tracker, Version 10 requires use of Tracer LCI-R Communications
Interface. For jobs requiring true discharge air sensing with Tracer/Tracker COMM-3 or COMM-4, contact Clarksville Light Commercial Marketing Support.
PC 41
Accessory Electric Heaters: Unit with heater is single circuit / single point power entry
Model Number BATHTRE105A BATHTRE110A BATHTRE114A BATHTRE118A BAYHTRE306A BAYHTRE312A BAYHTRE318A BAYHTRE323A Power Supply 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 208/240/3/60 208/240/3/60 208/240/3/60 208/240/3/60 KW Rating 3.8/5.0 7.5/10.0 10.4/13.8 13.2/17.6 4.5/6.0 9.0/12.0 13.1/17.4 17.3/23.0 Nominal No. of BTUH Stages 12,900/ 1 13,400 25,600/ 2 34,000 35,000/ 2 47,100 45,100/ 2 60,100 13,400/ 1 20,500 30,800/ 2 41,000 44,600/ 2 59,400 58,900/ 2 78,500 20,500 41,000 59,400 78,500 20,500 41,000 59,400 78,500 1 2 2 2 1 2 2 2 Used With TSC036-060E1 TSC036-060E1 TSC036-060E1 TSC048-060E1 TSC036-060E3 TSC036-060E3 TSC036-060E3 TSC060E3
SH SH SH SH SH SH SH SH
20 20 20 20 20 20 20 20
Accessories:
Model Number BAYCURB042A1 BAYQACB009A1 BAYQACB010A1 BAYECON085A2 BAYECON086A4 BAYDMPR051A2 BAYDMPR052A4 BAYDMPR053B BAYGARD036B Description Roof Curb Quick Adapt Roof Curb35 Quick Adapt Roof Curb35 0-100% Dry BulbEconomizer without Barometric Relief 0-100% Dry Bulb Economizer without Barometric Relief 0-50% Motorized Outside Air Damper 0-50% Motorized Outside Air Damper 0-50% Manual Outside Air Damper Tool-less Condenser Coil Hail Guard Used With TSC036-060E TSC036-060E3 TSC036-060E3 TSC036-060E_R TSC036-060E_E TSC036-060E_R TSC036-060E_E TSC036-060E TSC036-060E Mfg. Shipping Plant Weight LH 80 LH 100 LH 120 LH 40 LH LH LH LH LH 40 30 30 25 10
1 2 3 4 5
Lynn Haven Manufacturing has a No-Return policy for this roof curb. For use with ReliaTelTM controlled units only. BAYQACB009A adapts Voyager BAYCURB021B to accept Precedent 3-5 ton unit. BAYQACB010A adapts Voyager BAYCURB022B to accept Precedent 3-5 unit. For use with electromechanical controlled units only. TCD036A, TCD048A, TCD060A, WCD036A, WCD048A, WCD060A are not Voyager units. These units were manufactured in Ft. Smith, AR and will not fit any Voyager curbs.
PC 42
Description
Used With
See Note TSC036-060E TSC036-060E*R W/Econ. or Motorized OA Damper TSC036-060E*R W/Econ. or Motorized OA Damper TSC036-060E3 TSC036-060EA4,AW BAYECON085A TSC036-060E_R TSC036-060E_R TSC036-060E_R BAYECON085A BAYECON085A BAYECON0086A TSC036-120A_R TSC036-060E_R TSC036-060E_R TSC036-060E_R TSC036-060E_R TSC036-060E_E TSC036-060E_R TSC036-060E*R W/ReliaTel Options Module
ReliaTel Options Module Barometric Relief CO2 Sensor Kit, Wall Mounted CO2 Sensor Kit, Duct Mounted Crankcase Heater Crankcase Heater Remote Potentiometer Selective Resistance Service Tester Temperature Sensor High Temperature Stat Reference Enthalpy Kit Comparative Enthalpy Kit Enthalpy Control (Solid State) Clogged Filter Switch Fan Failure Switch Discharge Air Sensing Kit Comm-3/4 Trane Communications Interface Comm-3/4 LonTalk Communications Interface Anti-Short-Cycle Timer Evaporator Defrost Control (Frostat) Ventilation Override Kit
TM
1 Kits contain all necessary parts to achieve desired level of enthalpy control. 2 For ReliaTel microprocessor controlled units 3 4 5 6
only. Must be factory installed for electromechanical controlled units Used for true discharge air sensing in both heating and cooling.Required for supply air tempering. For use with ReliaTelTM controlled units only Barometric Relief accessory installs in ductwork for horizontal configuration. For downflow configuration, installs in the unit's horizontal return duct. See Installer's Guide for complete instructions. Cannot be used in conjunction with factory installed smoke detector.
field installed accessories Clogged Filter Switch (BAYDFPS003A), Fan Fail Switch (BAYDFPS004A), Discharge Air Sensing Kit (BAYTUBE004A) or Evaporator Defrost Control (Frostat) (BAYLOAM020B) unless the following options are factory installed: Frostat, Smoke Detector, Clogged Filter Switch, Fan Failure Switch, Discharge Air Sensing Kit. These factory installed options include the ReliaTelTM Options Module. For use with electromechanical controlled units only.
TM Controls to communicates with Tracer 100, Tracker, VariTrac II, and is the preferred method of communication to Tracer Summit. Interface allows a unit with ReliaTelTM Controls to communicate as a Trane LonTalk device or directly with generic LonTalk Network BAS Controls. Quantity 2 required for T*C092-120A Available for Cooling Units only.
PC 43
1 Used with Integrated Comfort Systems, any unit type. These sensors do not work with TCM. Consult BASD Marketing for them. 2 See Accessory IOM for operational characteristics. 3 Functional only with ReliaTel controls.
TM
BAYSENS006B,008B, 010B, & 019C Dual Thermistor Remote Zone Sensor TSC036-060E_R Digital Display Zone Sensor TSC036-060E_R Retrofit Wall Cover Plate Kit BAYSENS019C 7.25" x 6.0" Retrofit Wall Cover Plate Kit BAYSENS006,008 4.75" x 4.75" 010B,013,014C,017B
Thermostats:
Model Number Description BAYSTAT040A24 Programmable Thermostat BAYBASE008A Subbase 1-Stage Htg./Clg. BAYBASE006A Subbase 2-Stage Htg./Clg. BAYSENS033A Remote Wall Sensor BAYSENS034A Remote Duct Sensor TCONT200AN11AAElectronic, 1Htg/1Clg (Non Prog.) BAY28X1903 Locking Thermostat Cover for up to 4 units BAY24X042 DPDT Fan and Electric Heat Relay BAYSTAT050A 2Htg/2Clg Digital Display Programmable Thermostat BAYSTAT051A 1Htg/1Clg Digital Display Thermostat BAYSTAT052A 2Htg/2Clg Digital Display Programmable "TOUCHSCREEN" Thermostat BAYSTAT053A 3Htg/2Clg Digital Display Programmable Thermostat with Relative Humidity Sensing Built-In BAYSTAT055A 3Htg/2Clg Digital Display Thermostat BAYSTAT059A Return Air Remote Sensor BAYSTAT060A Wall Mounted Remote Sensor Used with TSC036-060E BAYSTAT040A BAYSTAT040A BAYSTAT040A BAYSTAT040A All Cooling/(Gas or Elec) Room Thermostats BAYSTAT051,052 TSC036-060E_R TSC036-060E_R TSC036-060E_R Mfg. Shipping Plant Weight CK/001 1 CK/001 1 CK/001 1 CK/001 1 CK/001 1 TY 1 TY 1 TY CK/001 CK/001 CK/001 1 1 1 1 1
TSC036-060E_R CK/001 (with Dehumidification Option) TSC036-060E_R BAYSTAT050A,051A, 052A,053A BAYSTAT050A,051A, 052A,053A CK/001 CK/001 CK/001
1 1 1
1 Requires DPDT Fan and Electric Heat Relay BAY24x042 when using electric heat. 2 Requires use of subbase BAYBASE006A or BAYBASE008A. 3 Do not use with programmable thermostats. 4 Thermostat does not include fan or system switches.
PC 44
Mfg. Shipping Plant Weight CK/001 1460 CK/001 1465 CK/001 1461 CK/001 1460 CK/001 1465 CK/001 1461 CK/001 1460 CK/001 1465 CK/001 1461
TCH150DW00B TCH150DW0BB Ov Motor TCH150DW0FB TCI Factory Installed Option Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI
Specifications: Downflow
Model Number TCD150D300B TCD150D30AB TCD150D30BB TCD150D30CB TCD150D30FB TCD150D30GB TCD150D400B TCD150D40AB TCD150D40BB TCD150D40CB TCD150D40FB TCD150D40GB TCD150DW00B TCD150DW0AB TCD150DW0BB TCD150DW0CB TCD150DW0FB TCD150DW0GB Power Supply 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 EER 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 Uncrated Dimensions (in.) Mfg. Shipping H W L Plant Weight 50 72 108 CK/001 1441 50 72 108 CK/001 1531 50 72 108 CK/001 1536 50 72 108 CK/001 1626 50 72 108 CK/001 1442 50 72 108 CK/001 1532 50 50 50 50 50 50 50 50 50 50 50 50 72 72 72 72 72 72 72 72 72 72 72 72 108 108 108 108 108 108 108 108 108 108 108 108 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 1441 1531 1536 1626 1442 1532 1441 1531 1536 1626 1442 1532
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Liquid line drier Operating charge of R-22 Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Short orifice refrigerant control Trane 3-D scroll compressors Sloped sheet metal drain pan Low pressure switches Dedicated horizontal and downflow designs Single point power for electric heat Complete line of optional electric heaters Quick-access panels with handles Internally enhanced coil tubing Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 5 year compressor warranty
PC 45
PC 46
Mfg. Plant
CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001
Shipping Weight
2 165 32 35 90 150 50 1 75 75 75 95 95 2 1 1 1 1 1 1 3 1 1 2
Extended Warranties (1 yr - 5 yr See Extended Warranty Section) BAYABRD002B ReliaTelTM Options Module See Note BAYCURB026B Downflow Roof Curb TCD150D BAYDMPR029C 0-25% Manual Outside Air Damper TCD150D/TCH150D BAYDMPR057A Motorized Outside Air Damper TCD150D/TCH150D BAYECON089A Downflow Economizer with TCD150D Barometric Relief BAYECON091A Horizontal Economizer TCH150D BAYGARD043B Tool-less Condenser Coil Hail Guard TC*150D BAYSTAT023 Remote Potentiometer BAYECON089A,091A, BAYDMPR057A BAYPWRX029A Power Exhaust for use TCD150D with Downflow Economizer/230v BAYPWRX030A Power Exhaust for use TCD150D with Downflow Economizer/460v BAYPWRX031A Power Exhaust for use TCD150DW with Downflow Economizer/575v BAYHSMT039B 5 HP Oversize Motor Kit TC*1503,4 BAYHSMT040B 5 HP Oversize Motor Kit TC*150DW BAYSERV001A Selective Resistance TCD150D Service Tester TCH150D BAYSENS016A Temperature Sensor TCD150D/TCH150D BAYFRST003A High Temperature Stat TCD150D/TCH150D Reference Enthalpy Kit BAYECON089A BAYENTH007A BAYECON091A Comparative Enthalpy Kit BAYECON089A BAYENTH008A BAYECON091A BAYDFPS005A Clogged Filter Switch TCD150D/TCH150D Fan Failure Switch BAYECON089A,091A BAYDFPS006A BAYDMPR057A BAYLOAM023A Evaporator Defrost TC*150D Control (Frostat) w/ReliaTel Options Module BAYTUBE008A Discharge Air Sensing Kit TCD150D BAYTUBE009A Discharge Air Sensing Kit TCD150D BAYVNOR002B Ventilation Override Kit TC*150D w/ReliaTel Options Module
15
3 2 2 7 7 4 4
1 For downflow use only. Cannot be adapted for horizontal units. 2 Kits contain all necessary parts to achieve desired level of enthalpy control. 3 Must be used with either field or factory installed TCI (Trane Communications Interface). 4 Used for true discharge air sensing in both heating and cooling models. Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B). 5 Clarksville Manufacturing has a no-return policy for this roof curb. 6 BAYABRD002B is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS005A), Fan Fail Switch (BAYDFPS006A), Discharge Air Sensing Kit (BAYTUBE008A or BAYTUBE009A), Frostat (BAYLOAM023A), Ventilation Override (BAYVNOR002B). 7 Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B).
FOR CHOICE OF ZONE SENSORS (MICRO THERMOSTATS) SEE LAST PAGE BEFORE "HIGH EFFICIENCY" PACKAGED COOLING
PC 47
Mfg. Shipping Plant Weight CK/001 1739 CK/001 1814 CK/001 1740 CK/001 1739 CK/001 1814 CK/001 1740 CK/001 1739 CK/001 1814 CK/001 1740
TCH180B400H TCH180B40BH Ov Motor TCH180B40FH TCI TCH180BW00H TCH180BW0BH Ov Motor TCH180BW0FH TCI
Specifications: Downflow
Model Number TCD180B300H TCD180B30AH TCD180B30BH TCD180B30FH TCD180B30GH TCD180B400H TCD180B40AH TCD180B40BH TCD180B40CH TCD180B40FH TCD180B40GH TCD180BW00H TCD180BW0AH TCD180BW0BH TCD180BW0CH TCD180BW0FH TCD180BW0GH Factory Installed Option Economizer Ov Motor TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Power Supply 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 Capacity Cooling (BTUH) 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 EER 9.9 9.9 9.9 9.9 9.9 9.9 9.9 9.9 9.9 9.9 9.9 9.9 9.9 9.9 9.9 9.9 9.9 Uncrated Dimensions (in.) Mfg. Shipping H W L Plant Weight 50 72 108 CK/001 1725 50 72 108 CK/001 1840 50 72 108 CK/001 1810 50 72 108 CK/001 1726 50 72 108 CK/001 1915 50 50 50 50 50 50 50 50 50 50 50 50 72 72 72 72 72 72 72 72 72 72 72 72 108 108 108 108 108 108 108 108 108 108 108 108 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 1725 1840 1810 1915 1726 1915 1725 1840 1810 1915 1726 1915
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Liquid line drier Operating charge of R-22 Short orifice refrigerant control Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Trane 3-D scroll compressors Low pressure switches Dedicated horizontal and downflow designs Single side access Single point power for electric heat Complete line of optional electric heaters Quick-access panels with handles Sloped sheet metal drain pan Internally enhanced coil tubing Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 5 year compressor warranty Optional extended warranties
PC 48
PC 49
BAYSTAT023 BAYPWRX029A BAYPWRX030A BAYPWRX031A BAYHSMT039B5 BAYHSMT040B5 BAYHSDR005B5 BAYSERV001A BAYSENS016A BAYFRST003A3 BAYENTH007A2 BAYENTH008A2 BAYDFPS005A8 BAYDFPS006A8 BAYLOAM023A BAYTUBE008A4 BAYTUBE009A4 BAYVNOR002B
Remote Potentiometer Power Exhaust for use with Downflow Economizer/230v Power Exhaust for use with Downflow Economizer/460v Power Exhaust for use with Downflow Economizer/575v 5 HP Oversize Motor Kit 5 HP Oversize Motor Kit High Static Drive Selective Resistance Service Tester Temperature Sensor High Temperature Stat Reference Enthalpy Kit Comparative Enthalpy Kit Clogged Filter Switch Fan Failure Switch Evaporator Defrost Control (Frostat) Discharge Air Sensing Kit Discharge Air Sensing Kit Ventilation Override Kit
1 For downflow use only. Cannot be adapted for horizontal units. 2 Kits contain all necessary parts to achieve desired level of enthalpy control. 3 Must be used with either field or factory installed TCI (Trane Communications Interface). 4 Used for true discharge air sensing in both heating and cooling models. Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B). 5 High static drive and oversize motors are mutually exclusive. Do not combine. 6 Clarksville Manufacturing has a no-return policy for this roof curb. 7 BAYABRD002B is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS005A), Fan Fail Switch (BAYDFPS006A), Discharge Air Sensing Kit (BAYTUBE008A or BAYTUBE009A), Frostat (BAYLOAM023A), Ventilation Override (BAYVNOR002B). 8 Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B).
FOR CHOICE OF ZONE SENSORS (MICRO THERMOSTATS) SEE LAST PAGE BEFORE "HIGH EFFICIENCY" PACKAGED COOLING PC 50 Effective date: January 1, 2007
TCD180B CK/001 TCH180B TCH/D180BW CK/001 TCH/D180B CK/001 TCD180B CK/001 TCH180B TCD180B CK/001 TCH180B TCD180B CK/001 TCH180B BAYECON089A CK/001 BAYECON091A BAYECON089A CK/001 BAYECON091A TCD180B CK/001 TCH180B BAYECON089A,091A CK/001 BAYDMPR057A TC*180B CK/001 w/ReliaTel Options Module TCD180B CK/001 TCH180B CK/001 TC*180B CK/001 w/ReliaTel Options Module
Mfg. Shipping Plant Weight CK/001 1820 CK/001 1930 CK/001 1821 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 1820 1930 1821 1820 1930 1821
TCH210C400E TCH210C40BE Ov Motor TCH210C40FE TCI TCH210CW00E TCH210CW0BE Ov Motor TCH210CW0FE TCI
Specifications: Downflow
Model Number TCD210C300E TCD210C30AE TCD210C30BE TCD210C30CE TCD210C30FE TCD210C30GE TCD210C400E TCD210C40AE TCD210C40BE TCD210C40CE TCD210C40FE TCD210C40GE TCD210CW00E TCD210CW0AE TCD210CW0BE TCD210CW0CE TCD210CW0FE TCD210CW0GE Factory Installed Option Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Power Supply 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 Capacity Cooling (BTUH) 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 EER 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 Uncrated Dimensions (in.) H W L 50 72 108 50 72 108 50 72 108 50 72 108 50 72 108 50 72 108 50 50 50 50 50 50 50 50 50 50 50 50 72 72 72 72 72 72 72 72 72 72 72 72 108 108 108 108 108 108 108 108 108 108 108 108 Mfg. Shipping Plant Weight CK/001 1806 CK/001 1921 CK/001 1916 CK/001 2031 CK/001 1807 CK/001 1922 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 1806 1921 1916 2031 1807 1922 1806 1921 1916 2031 1807 1922
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Liquid line drier Operating charge of R-22 Short orifice refrigerant control Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Trane 3-D scroll compressors Low pressure switches Dedicated horizontal and downflow designs Single side access Single point power for electric heat Complete line of optional electric heaters Quick-access panels with handles Sloped sheet metal drain pan Internally enhanced coil tubing Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 5 year compressor warranty Optional extended warranties
PC 51
PC 52
Model Mfg. Shipping Number Description Used With Plant Weight Extended Warranties (1 yr - 5 yr See Extended Warranty Section) BAYABRD002B ReliaTelTM Options Module See Note 7 CK/001 2 BAYCURB026B16 Downflow Roof Curb TCD210C CK/001 205 BAYDMPR029C 0-25% Manual Outside Air Damper TCD210C CK/001 32 TCH210C BAYDMPR057A Motorized Outside Air Damper TCD210C CK/001 60 TCH210C BAYECON089A Downflow Economizer with TCD210C CK/001 112 Barometric Relief BAYECON091A Horizontal Economizer TCH210C CK/001 85 BAYGARD044B Tool-less Condenser Coil Hail Guard TC*210C CK/001 50 BAYSTAT023 Remote Potentiometer BAYECON089A,091A CK/001 1 BAYDMPR057A BAYPWRX029A Power Exhaust for use TCD210C3 CK/001 95 with Downflow Economizer/230v BAYPWRX030A Power Exhaust for use TCD210C4 CK/001 95 with Downflow Economizer/460v BAYPWRX031A Power Exhaust for use TCD210CW CK/001 95 with Downflow Economizer/575v BAYHSMT059A4 7 HP Oversize Motor Kit TCD210C3 CK/001 110 TCH210C3 BAYHSMT060A4 7 HP Oversize Motor Kit TCD/TCH210C4 CK/001 110 BAYHSMT061A4 7 HP Oversize Motor Kit/575v TCD/TCH210CW CK/001 110 BAYLSDR004A4 Low Static Drive TCD/TCH210C CK/001 15 BAYSERV001A Selective Resistance TCD210C CK/001 2 Service Tester TCH210C BAYSENS016A Temperature Sensor TCD210C CK/001 1 TCH210C BAYFRST003A3 High Temperature Stat TCD210C CK/001 1 TCH210C BAYENTH007A2 Reference Enthalpy Kit BAYECON089A,091A CK/001 1 BAYENTH008A2 Comparative Enthalpy Kit BAYECON089A,091A CK/001 1 BAYDFPS005A8 Clogged Filter Switch TCD210C CK/001 1 TCH210C BAYDFPS006A8 Fan Failure Switch BAYECON089A,091A CK/001 1 BAYDMPR057A BAYLOAM023A Evaporator Defrost TC*210C CK/001 3 Control (Frostat) w/ReliaTel Options Module BAYTUBE008A5 Discharge Air Sensing Kit TCD210C CK/001 1 BAYTUBE009A5 Discharge Air Sensing Kit TCH210C CK/001 1 BAYVNOR002B Ventilation Override Kit TC*210C CK/001 2 w/ReliaTel Options Module
1 For downflow use only. Cannot be adapted for horizontal units. 2 Kits contain all necessary parts to achieve desired level of enthalpy control. 3 Must be used with either field or factory installed TCI (Trane Communications Interface). 4 Low static drive and oversized motors are mutually exclusive. Do not combine. 5 Used for true discharge air sensing in both heating and cooling models. Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B). 6 Clarksville Manufacturing has a no-return policy for this roof curb. 7 BAYABRD002B is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS005A), Fan Fail Switch (BAYDFPS006A), Discharge Air Sensing Kit (BAYTUBE008A or BAYTUBE009A), Frostat (BAYLOAM023A), Ventilation Override (BAYVNOR002B). 8 Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B).
FOR CHOICE OF ZONE SENSORS (MICRO THERMOSTATS) SEE LAST PAGE BEFORE "HIGH EFFICIENCY" PACKAGED COOLING PC 53 Effective date: January 1, 2007
Mfg. Shipping Plant Weight CK/001 2309 CK/001 2399 CK/001 2310 CK/001 2309 CK/001 2399 CK/001 2310 CK/001 2309 CK/001 2399 CK/001 2310
Specifications: Downflow
Model Number TCD240B300J TCD240B30AJ TCD240B30BJ TCD240B30CJ TCD240B30FJ TCD240B30GJ TCD240B400J TCD240B40AJ TCD240B40BJ TCD240B40CJ TCD240B40FJ TCD240B40GJ TCD240BW00J TCD240BW0AJ TCD240BW0BJ TCD240BW0CJ TCD240BW0FJ TCD240BW0GJ Factory Installed Option Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Power Supply 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 Capacity Cooling (BTUH) EER 242,000 9.7 242,000 9.7 242,000 9.7 242,000 9.7 242,000 9.7 242,000 9.7 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 Uncrated Dimensions (in.) H W L 54 86 123 54 86 123 54 86 123 54 86 123 54 86 123 54 86 123 54 54 54 54 54 54 54 54 54 54 54 54 86 86 86 86 86 86 86 86 86 86 86 86 123 123 123 123 123 123 123 123 123 123 123 123 Mfg. Shipping Plant Weight CK/001 2293 CK/001 2428 CK/001 2383 CK/001 2518 CK/001 2294 CK/001 2429 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 2293 2428 2383 2518 2294 2429 2293 2428 2383 2518 2294 2429
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Liquid line drier Operating charge of R-22 Short orifice refrigerant control Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Trane 3-D scroll compressors Low pressure switches Dedicated horizontal and downflow designs Single side access Single point power for electric heat Complete line of optional electric heaters Quick-access panels with handles Sloped sheet metal drain pan Internally enhanced coil tubing Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 1 year compressor warranty Optional extended warranties
PC 54
Mfg. Shipping Plant Weight CK/001 2395 CK/001 2395 CK/001 CK/001 CK/001 CK/001 2395 2395 2395 2395
Specifications: Downflow
Model Number TCD300B300H TCD300B30AH TCD300B30FH TCD300B30GH TCD300B400H TCD300B40AH TCD300B40FH TCD300B40GH TCD300BW00H TCD300BW0AH TCD300BW0FH TCD300BW0GH Factory Installed Option Economizer TCI Econ/TCI Economizer TCI Econ/TCI Economizer TCI Econ/TCI Power Supply 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 Capacity Cooling (BTUH) 290,000 290,000 290,000 290,000 290,000 290,000 290,000 290,000 290,000 290,000 290,000 290,000 EER 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 Uncrated Dimensions (in.) Mfg. Shipping H W L Plant Weight 54 86 123 CK/001 2350 54 86 123 CK/001 2485 54 86 123 CK/001 2350 54 86 123 CK/001 2485 54 54 54 54 54 54 54 54 86 86 86 86 86 86 86 86 123 123 123 123 123 123 123 123 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 2350 2485 2350 2485 2350 2485 2350 2485
Features:
ReliaTel Controls Built in anti-short cycle, time-delay relay and minimum on time controls Belt Drive Evaporator Motor Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Liquid line drier Fork lift channels Operating charge of R-22 Short orifice refrigerant control Weather tight top and cabinet Trane 3-D scroll compressors Low pressure switches Dedicated horizontal and downflow designs Single side access Single point power for electric heat Complete line of optional electric heaters Quick-access panels with handles Internally enhanced coil tubing Sloped sheet metal drain pan Low ambient to 0 F standard Colored and numbered wiring UL listed ICS compatibility with either factory or field-installed Trane Communications Interface (TCI) 1 year compressor warranty Optional extended warranties
PC 55
PC 56
Model Mfg. Number Description Used With Plant Extended Warranties (1 yr - 5 yr See Extended Warranty Section) BAYABRD002B ReliaTelTM Options Module See Note 7 CK/001 BAYCURB027B16 Downflow Roof Curb TCD240-300B CK/001 BAYDMPR029C 0-25% Manual Outside Air Damper TCD240-300B CK/001 TCH240-300B BAYDMPR058A Motorized Outside Air Damper TCD240-300B CK/001 TCH240-300B BAYECON090A Downflow Economizer with TCD240-300B CK/001 Barometric Relief BAYECON092A Horizontal Economizer TCH240-300B CK/001 BAYGARD045A Tool-less Condenser Coil Hail Guard TC*240B CK/001 BAYGARD047A Tool-less Condenser Coil Hail Guard TC*300B CK/001 BAYSTAT023 Remote Potentiometer BAYECON090A,092A CK/001 BAYDMPR058A BAYPWRX029A Power Exhaust for use TCD240-300B3 CK/001 with Downflow Economizer/230v BAYPWRX030A Power Exhaust for use TCD240-300B4 CK/001 with Downflow Economizer/460v BAYPWRX031A Power Exhaust for use TCD240-300BW CK/001 with Downflow Economizer/575v BAYHSMT042A5 7 HP Oversize Motor Kit TCD/TCH240BW CK/001 BAYHSMT098A5 7 HP Oversize Motor Kit TCD240B3/TCH240B3 CK/001 BAYHSMT099A5 7 HP Oversize Motor Kit TCD240B4/TCH240B4 CK/001 BAYHSDR005B5 High Static Drive TCD/TCH240B CK/001 BAYHSDR010A5 High Static Drive TCD/TCH300B CK/001 BAYLSDR002A Low Static Drive TCD300B/TCH300B CK/001 BAYSERV001A Selective Resistance TCD240-300B CK/001 Service Tester TCH240-300B BAYSENS016A Temperature Sensor TCD240-300B CK/001 TCH240-300B High Temperature Stat TCD240-300B CK/001 BAYFRST003A3 TCH240-300B BAYENTH007A2 Reference Enthalpy Kit BAYECON090A,092A CK/001 BAYENTH008A2 Comparative Enthalpy Kit BAYECON090A,092A CK/001 BAYDFPS005A8 Clogged Filter Switch TCD240-300B CK/001 TCH240-300B BAYDFPS006A8 Fan Failure Switch BAYECON090A,092A CK/001 BAYDMPR058A BAYLOAM023A Evaporator Defrost TC*240-300B CK/001 Control (Frostat) w/ReliaTel Options Module BAYTUBE008A4 Discharge Air Sensing Kit TCD240-300B CK/001 BAYTUBE009A4 Discharge Air Sensing Kit TCH240-300B CK/001 BAYVNOR002B Ventilation Override Kit TC*240-300B CK/001 w/ReliaTel Options Module
1 For downflow use only. Cannot be adapted for horizontal units. 2 Kits contain all necessary parts to achieve desired level of enthalpy control. 3 Must be used with either field or factory installed TCI (Trane Communications Interface). 4 Used for true discharge air sensing in both heating and cooling models. Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B). 5 Low and high static drives and oversize motors are mutually exclusive. Do not combine. 6 Clarksville Manufacturing has a no-return policy for this roof curb. 7 BAYABRD002B is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS005A), Fan Fail Switch (BAYDFPS006A), Discharge Air Sensing Kit (BAYTUBE008A or BAYTUBE009A), Frostat (BAYLOAM023A), Ventilation Override (BAYVNOR002B). 8 Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B).
FOR CHOICE OF ZONE SENSORS (MICRO THERMOSTATS) SEE LAST PAGE BEFORE "HIGH EFFICIENCY" PACKAGED COOLING PC 57 Effective date: January 1, 2007
Mfg. Shipping Plant Weight CK/001 1860 CK/001 1900 CK/001 1861 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 1860 1900 1861 1860 1900 1861
Specifications: Downflow
Model Number TCD150E300A TCD150E30AA TCD150E30BA TCD150E30CA TCD150E30FA TCD150E30GA TCD150E400A TCD150E40AA TCD150E40BA TCD150E40CA TCD150E40FA TCD150E40GA TCD150EW00A TCD150EW0AA TCD150EW0BA TCD150EW0CA TCD150EW0FA TCD150EW0GA Power Supply 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 EER 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 Uncrated Dimensions (in.) H W L 50 72 108 50 72 108 50 72 108 50 72 108 50 72 108 50 72 108 50 50 50 50 50 50 50 50 50 50 50 50 72 72 72 72 72 72 72 72 72 72 72 72 108 108 108 108 108 108 108 108 108 108 108 108 Mfg. Shipping Plant Weight CK/001 1860 CK/001 1950 CK/001 1900 CK/001 1990 CK/001 1861 CK/001 1951 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 1860 1950 1900 1990 1861 1951 1860 1950 1900 1990 1861 1951
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Liquid line drier Operating charge of R-410A Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Short orifice refrigerant control Trane 3-D scroll compressors Sloped sheet metal drain pan Low pressure switches Dedicated horizontal and downflow designs Single point power for electric heat Complete line of optional electric heaters Quick-access panels with handles Internally enhanced coil tubing Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 5 year compressor warranty
PC 58
PC 59
Description
Used With
See Note TCD150E TCD150E TCH150E TCD150E TCH150E TCD150E
Shipping Weight
2 165 32 35 90 150 50 1 75 75 75 95 95 2 1 1 1 1 1 1 3 1 1 2
15
ReliaTelTM Options Module Downflow Roof Curb 0-25% Manual Outside Air Damper Motorized Outside Air Damper
BAYDMPR057A BAYECON089A BAYECON091A BAYGARD043B BAYSTAT023 BAYPWRX029A BAYPWRX030A BAYPWRX031A BAYHSMT039B BAYHSMT040B BAYSERV001A BAYSENS016A BAYFRST003A
3 2 2 7 7 4 4
1 For downflow use only. Cannot be adapted for horizontal units. 2 Kits contain all necessary parts to achieve desired level of enthalpy control. 3 Must be used with either field or factory installed TCI (Trane Communications Interface). 4 Used for true discharge air sensing in both heating and cooling models. Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B). 5 Clarksville Manufacturing has a no-return policy for this roof curb. 6 BAYABRD002B is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS005A), Fan Fail Switch (BAYDFPS006A), Discharge Air Sensing Kit (BAYTUBE008A or BAYTUBE009A), Frostat (BAYLOAM023A), Ventilation Override (BAYVNOR002B). 7 Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B).
Downflow Economizer with CK/001 Barometric Relief Horizontal Economizer TCH150E CK/001 Tool-less Condenser Coil Hail Guard TC*150E CK/001 Remote Potentiometer BAYECON089A,091A, CK/001 BAYDMPR057A Power Exhaust for use TCD150E CK/001 with Downflow Economizer/230v Power Exhaust for use TCD150E CK/001 with Downflow Economizer/460v Power Exhaust for use TCD150EW CK/001 with Downflow Economizer/575v 5 HP Oversize Motor Kit TC*150E3,4 CK/001 5 HP Oversize Motor Kit TC*150EW CK/001 Selective Resistance TCD150E CK/001 Service Tester TCH150E Temperature Sensor TCD150E CK/001 TCH150E High Temperature Stat TCD150E CK/001 TCH150E Reference Enthalpy Kit BAYECON089A CK/001 BAYECON091A Comparative Enthalpy Kit BAYECON089A CK/001 BAYECON091A Clogged Filter Switch TCD150E CK/001 TCH150E Fan Failure Switch BAYECON089A,091A CK/001 BAYDMPR057A Evaporator Defrost TC*150E CK/001 Control (Frostat) w/ReliaTel Options Module Discharge Air Sensing Kit TCD150E CK/001 Discharge Air Sensing Kit TCD150E CK/001 Ventilation Override Kit TC*150E CK/001 w/ReliaTel Options Module
PC 60
Mfg. Shipping Plant Weight CK/001 2370 CK/001 2410 CK/001 2371 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 2370 2410 2371 2370 2410 2371
Specifications: Downflow
Model Number TCD180E300A TCD180E30AA TCD180E30BA TCD180E30CA TCD180E30FA TCD180E30GA TCD180E400A TCD180E40AA TCD180E40BA TCD180E40CA TCD180E40FA TCD180E40GA TCD180EW00A TCD180EW0AA TCD180EW0BA TCD180EW0CA TCD180EW0FA TCD180EW0GA Factory Installed Option Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Power Supply 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 Capacity Cooling (BTUH) 178,000 178,000 178,000 150,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 EER 11.0 11.0 11.0 9.8 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 Uncrated Dimensions (in.) H W L 54 86 123 54 86 123 54 86 123 50 72 108 54 86 123 54 86 123 54 54 54 54 54 54 54 54 54 54 54 54 86 86 86 86 86 86 86 86 86 86 86 86 123 123 123 123 123 123 123 123 123 123 123 123 Mfg. Shipping Plant Weight CK/001 2370 CK/001 2460 CK/001 2410 CK/001 2490 CK/001 2371 CK/001 2461 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 2370 2460 2410 2490 2371 2461 2370 2460 2410 2490 2371 2461
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Liquid line drier Operating charge of R-410A Short orifice refrigerant control Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Trane 3-D scroll compressors Low pressure switches Dedicated horizontal and downflow designs Single side access Single point power for electric heat Complete line of optional electric heaters Quick-access panels with handles Sloped sheet metal drain pan Internally enhanced coil tubing Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 5 year compressor warranty Optional extended warranties
PC 61
PC 62
Description ReliaTelTM Options Module Downflow Roof Curb 0-25% Manual Outside Air Damper Motorized Outside Air Damper Downflow Economizer with Barometric Relief Horizontal Economizer Remote Potentiometer Power Exhaust for use with Downflow Economizer/230v Power Exhaust for use with Downflow Economizer/460v Power Exhaust for use with Downflow Economizer/575v 5 HP Oversize Motor Kit 5 HP Oversize Motor Kit High Static Drive Selective Resistance Service Tester Temperature Sensor High Temperature Stat Reference Enthalpy Kit Comparative Enthalpy Kit Clogged Filter Switch Fan Failure Switch Evaporator Defrost Control (Frostat) Discharge Air Sensing Kit Discharge Air Sensing Kit Ventilation Override Kit
Used With See Note 7 TCD180E TCD180E TCH180E TCD180E TCH180E TCD180E TCH180E
BAYSTAT023 BAYPWRX029A BAYPWRX030A BAYPWRX031A BAYHSMT039B5 BAYHSMT040B5 BAYHSDR005B5 BAYSERV001A BAYSENS016A BAYFRST003A3 BAYENTH007A2 BAYENTH008A2 BAYDFPS005A8 BAYDFPS006A8 BAYLOAM023A BAYTUBE008A4 BAYTUBE009A4 BAYVNOR002B
1 For downflow use only. Cannot be adapted for horizontal units. 2 Kits contain all necessary parts to achieve desired level of enthalpy control. 3 Must be used with either field or factory installed TCI (Trane Communications Interface). 4 Used for true discharge air sensing in both heating and cooling models. Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B). 5 High static drive and oversize motors are mutually exclusive. Do not combine. 6 Clarksville Manufacturing has a no-return policy for this roof curb. 7 BAYABRD002B is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS005A), Fan Fail Switch (BAYDFPS006A), Discharge Air Sensing Kit (BAYTUBE008A or BAYTUBE009A), Frostat (BAYLOAM023A), Ventilation Override (BAYVNOR002B). 8 Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B).
TCD180E CK/001 TCH180E TCH/D180EW CK/001 TCH/D180E CK/001 TCD180E CK/001 TCH180E TCD180E CK/001 TCH180E TCD180E CK/001 TCH180E BAYECON089A CK/001 BAYECON091A BAYECON089A CK/001 BAYECON091A TCD180E CK/001 TCH180E BAYECON089A,091A CK/001 BAYDMPR057A TC*180E CK/001 w/ReliaTel Options Module TCD180E CK/001 TCH180E CK/001 TC*180E CK/001 w/ReliaTel Options Module
PC 63
Specifications: Downflow
Model Number TCD210E300A TCD210E30AA TCD210E30BA TCD210E30CA TCD210E30FA TCD210E30GA TCD210E400A TCD210E40AA TCD210E40BA TCD210E40CA TCD210E40FA TCD210E40GA TCD210EW00A TCD210EW0AA TCD210EW0BA TCD210EW0CA TCD210EW0FA TCD210EW0GA Factory Installed Option Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Power Supply 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 Capacity Cooling (BTUH) 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 EER 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 Uncrated Dimensions (in.) H W L 54 86 123 54 86 123 54 86 123 54 86 123 54 86 123 54 86 123 54 54 54 54 54 54 54 54 54 54 54 54 86 86 86 86 86 86 86 86 86 86 86 86 123 123 123 123 123 123 123 123 123 123 123 123 Mfg. Shipping Plant Weight CK/001 2375 CK/001 2465 CK/001 2415 CK/001 2495 CK/001 2376 CK/001 2466 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 2375 2465 2415 2495 2376 2466 2375 2465 2415 2495 2376 2466
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Liquid line drier Operating charge of R-410A Short orifice refrigerant control Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Trane 3-D scroll compressors Low pressure switches Dedicated horizontal and downflow designs Single side access Single point power for electric heat Complete line of optional electric heaters Quick-access panels with handles Sloped sheet metal drain pan Internally enhanced coil tubing Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 5 year compressor warranty Optional extended warranties
PC 64
PC 65
1 For downflow use only. Cannot be adapted for horizontal units. 2 Kits contain all necessary parts to achieve desired level of enthalpy control. 3 Must be used with either field or factory installed TCI (Trane Communications Interface). 4 Low static drive and oversized motors are mutually exclusive. Do not combine. 5 Used for true discharge air sensing in both heating and cooling models. Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B). 6 Clarksville Manufacturing has a no-return policy for this roof curb. 7 BAYABRD002B is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS005A), Fan Fail Switch (BAYDFPS006A), Discharge Air Sensing Kit (BAYTUBE008A or BAYTUBE009A), Frostat (BAYLOAM023A), Ventilation Override (BAYVNOR002B). 8 Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B).
TCD210E3 CK/001 TCH210E3 TCD/TCH210E4 CK/001 TCD/TCH210EW CK/001 TCD/TCH210E CK/001 TCD210E CK/001 TCH210E TCD210E CK/001 TCH210E TCD210E CK/001 TCH210E BAYECON089A,091A CK/001 BAYECON089A,091A CK/001 TCD210E CK/001 TCH210E BAYECON089A,091A CK/001 BAYDMPR057A TC*210E CK/001 w/ReliaTel Options Module TCD210E CK/001 TCH210E CK/001 TC*210E CK/001 w/ReliaTel Options Module
PC 66
Mfg. Shipping Plant Weight CK/001 2450 CK/001 2490 CK/001 2451 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 2450 2490 2451 2309 2490 2451
Specifications: Downflow
Model Number TCD240E300A TCD240E30AA TCD240E30BA TCD240E30CA TCD240E30FA TCD240E30GA TCD240E400A TCD240E40AA TCD240E40BA TCD240E40CA TCD240E40FA TCD240E40GA TCD240EW00A TCD240EW0AA TCD240EW0BA TCD240EW0CA TCD240EW0FA TCD240EW0GA Factory Installed Option Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Power Supply 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 Capacity Cooling (BTUH) 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 EER 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 Uncrated Dimensions (in.) H W L 54 86 123 54 86 123 54 86 123 54 86 123 54 86 123 54 86 123 54 54 54 54 54 54 54 54 54 54 54 54 86 86 86 86 86 86 86 86 86 86 86 86 123 123 123 123 123 123 123 123 123 123 123 123 Mfg. Shipping Plant Weight CK/001 2450 CK/001 2540 CK/001 2490 CK/001 2580 CK/001 2451 CK/001 2541 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 2450 2540 2490 2580 2451 2541 2450 2540 2490 2580 2451 2541
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Liquid line drier Operating charge of R-410A Short orifice refrigerant control Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Trane 3-D scroll compressors Low pressure switches Dedicated horizontal and downflow designs Single side access Single point power for electric heat Complete line of optional electric heaters Quick-access panels with handles Sloped sheet metal drain pan Internally enhanced coil tubing Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 1 year compressor warranty
PC 67
12-1/2 25 Ton
Zone Sensors: (Micro Thermostats to be used with Micro Units)
Model Number BAYSENS006B BAYSENS008B BAYSENS010B BAYSENS019C BAYSENS013C1 BAYSENS014C1 BAYSENS017B BAYSENS032A3 BAYSENS035A3 BAYMTPL003B BAYMTPL004B BAYSTAT050A BAYSTAT052A BAYSTAT053A Description Single Setpoint Manual Changeover Dual Setpoint Manual or Auto Changeover Dual Setpoint Man. or Auto Changeover with System Function Lights Programmmable Night Setback w/System Function Lights Room Sensor w/ Override Button Room Sensor w/ Temp. Adjustment And Override Remote Room Sensor Dual Thermistor Remote Zone Sensor Digital Display Zone Sensor Retrofit Wall Cover Plate Kit 7.25"x6.0" Retrofit Wall Cover Plate Kit 4.75"x4.75" 2Htg/2Clg Digital Display Programmable Thermostat 2Htg/2Clg Digital Display Programmable "TOUCHSCREEN" Thermostat 3Htg/2Clg Digital Display Programmable Thermostat with Relative Humidity Sensing Built-In 3Htg/2Clg Digital Display Thermostat Return Air Remote Sensor Wall Mounted Remote Sensor
TM
Packaged Cooling
Mfg. Shipping Plant Weight CK/001 1 CK/001 1 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 1 1 1 1 1 1 1 1
Used with TC*150-300 TC*150-300 TC*150-300 TC*150-300 TC*150-300 TC*150-300 BAYSENS006B, 008B, 010B & 019C TC*150-300 TC*150-300 BAYSENS019C BAYSENS006,008,010B, 017B & 013, 014C TC*150-300 TC*150-300
1 1 1 1
TC*150-300 CK/001 (with Dehumidification Option) TC*150-300 CK/001 BAYSTAT050A, 052A,053A CK/001 BAYSTAT050A, 052A,053A CK/001
1 Used with Integrated Comfort Systems, any unit type. These sensors do not work with TCM. Consult BASD Marketing for them. 2 See Accessory IOM for operational characteristics. 3 Functional only with ReliaTel controls.
* Either horizontal or downflow models.
1 1 1
Controls:
Model Number BAYCO2K002B BAYCO2K004B BAYICSI004B BAYLTCI003B Description CO2 Sensor Kit, Wall Mounted CO2 Sensor Kit, Duct Mounted Field Installed TCI (Trane Communication Interface) LonTalk Interface Used with TC*150-300 w/Economizer TC*150-300 w/Economizer TC*150-300 TC*150-300 Mfg. Plant CK/001 CK/001 CK/001 CK/001 Shipping Weight 3 3.5 1 1
PC 68
Mfg. Shipping Plant Weight CK/001 1776 CK/001 1851 CK/001 1777 CK/001 1776 CK/001 1851 CK/001 1777 CK/001 1776 CK/001 1851 CK/001 1777
TCH151C400C TCH151C40BC Ov Motor TCH151C40FC TCI TCH151CW00C TCH151CW0BC Ov Motor TCH151CW0FC TCI
Specifications: Downflow
Model Number TCD151C300B TCD151C30AB TCD151C30BB TCD151C30CB TCD151C30FB TCD151C30GB TCD151C30HB TCD151C30JB TCD151C30KB TCD151C30LB TFD151C30MB TFD151C30NB TFD151C30PB TFD151C30RB TCD151C400B TCD151C40AB TCD151C40BB TCD151C40CB TCD151C40FB TCD151C40GB TCD151C40HB TCD151C40JB TCD151C40KB TCD151C40LB TFD151C40MB TFD151C40NB TFD151C40PB TFD151C40RB Factory Installed Option Economizer Ov Motor Econ/OvMtr TCI Econ/TCI TXV TXV/OvMtr TXV/OvMtr/Econ TXV/Econ Reheat Coil Econ/Reheat Coil Ov Mtr/Reheat Coil Econ/Ov Mtr/Reheat Coil Economizer Ov Motor Econ/OvMtr TCI Econ/TCI TXV TXV/OvMtr TXV/OvMtr/Econ TXV/Econ Reheat Coil Econ/Reheat Coil Ov Mtr/Reheat Coil Econ/Ov Mtr/Reheat Coil Power Supply 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 Capacity Cooling (BTUH) 154,000 154,000 154,000 154,000 154,000 154,000 154,000 154,000 154,000 154,000 154,000 154,000 154,000 154,000 154,000 154,000 154,000 154,000 154,000 154,000 154,000 154,000 154,000 154,000 154,000 154,000 154,000 154,000 PC 69 EER 11.3 11.3 11.3 11.3 11.3 11.3 11.3 11.3 11.3 11.3 11.3 11.3 11.3 11.3 11.3 11.3 11.3 11.3 11.3 11.3 11.3 11.3 11.3 11.3 11.3 11.3 11.3 11.3 Uncrated Dimensions (in.) H W L 50 72 108 50 72 108 50 72 108 50 72 108 50 72 108 50 72 108 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 Mfg. Shipping Plant Weight CK/001 1762 CK/001 1877 CK/001 1837 CK/001 1952 CK/001 1763 CK/001 1878 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 1762 1877 1837 1952 1881 2032 1992 2107 1762 1877 1837 1952 1763 1878 1762 1877 1837 1952 1881 2032 1992 2107
Uncrated Dimensions (in.) H W L 50 72 108 50 72 108 50 72 108 50 72 108 50 72 108 50 72 108 50 50 50 50 50 50 50 50 72 72 72 72 72 72 72 72 108 108 108 108 108 108 108 108
Mfg. Shipping Plant Weight CK/001 1762 CK/001 1877 CK/001 1837 CK/001 1952 CK/001 1763 CK/001 1878 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 1762 1877 1837 1952 1881 2032 1992 2107
Features
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Liquid line drier Operating charge of R-22 Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Short orifice refrigerant control High efficiency scroll compressors Low pressure switches Dedicated horizontal and downflow designs Single side access Single point power for electric heat Complete line of optional electric heaters Quick-access panels with handles Internally enhanced coil tubing Low ambient cooling to 0 F standard Sloped sheet metal drain pan Colored and numbered wiring UL listed and CSA certified 5 year compressor warranty Optional extended warranties
PC 70
PC 71
BAYSTAT023 BAYPWRX029A BAYPWRX030A BAYPWRX031A BAYHSMT039B4 BAYHSMT040B4 BAYHSDR002B4 BAYSERV001A BAYSENS016A BAYFRST003A3 BAYENTH007A2 BAYENTH008A2 BAYDFPS005A8 BAYDFPS006A8 BAYLOAM023A BAYTUBE008A5 BAYTUBE009A5 BAYVNOR002B
Remote Potentiometer Power Exhaust for use with Downflow Economizer/ 230v Power Exhaust for use with Downflow Economizer/ 460v Power Exhaust for use with Downflow Economizer/ 575v 5 HP Oversize Motor Kit 5 HP Oversize Motor Kit High Static Drive Selective Resistance Service Tester Temperature Sensor High Temperature Stat Reference Enthalpy Kit Comparative Enthalpy Kit Clogged Filter Switch Fan Failure Switch Evaporator Defrost Control (Frostat) Discharge Air Sensing Kit Discharge Air Sensing Kit Ventilation Override Kit
1 For downflow use only. Cannot be adapted for horizontal units. 2 Kits contain all necessary parts to achieve desired level of enthalpy control. 3 Must be used with either field or factory installed TCI (Trane Communications Interface). 4 High static drive and oversized motors are mutually exclusive. Do not combine. 5 Used for true discharge air sensing in both heating and cooling models. Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B). 6 Clarksville Manufacturing has a no-return policy for this roof curb. 7 BAYABRD002B is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS005A), Fan Fail Switch (BAYDFPS006A), Discharge Air Sensing Kit (BAYTUBE008A or BAYTUBE009A), Frostat (BAYLOAM023A), Ventilation Override (BAYVNOR002B). 8 Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B).
PC 72 Effective date: January 1, 2007
TCD151C CK/001 TCH151C TCH/D151CW CK/001 TCD151C CK/001 TCH151C TCD151C CK/001 TCH151C TCD151C CK/001 TCH151C TCD151C CK/001 TCH151C BAYECON090A CK/001 BAYECON092A BAYECON090A CK/001 BAYECON092A TCD151C CK/001 TCH151C BAYECON089A,091A CK/001 BAYDMPR057A TC*151C CK/001 w/ReliaTel Options Module TCD151C CK/001 TCH151C CK/001 TC*151C CK/001 w/ReliaTel Options Module
Mfg. Shipping Plant Weight CK/001 2309 CK/001 2384 CK/001 2310 CK/001 2309 CK/001 2384 CK/001 2310 CK/001 2309 CK/001 2384 CK/001 2310
TCH181C400C TCH181C40BC Ov Motor TCH181C40FC TCI TCH181CW00C TCH181CW0BC Ov Motor TCH181CW0FC TCI
Specifications: Downflow
Model Number TCD181C300C TCD181C30AC TCD181C30BC TCD181C30CC TCD181C30FC TCD181C30GC TCD181C30HC TCD181C30JC TCD181C30KC TCD181C30LC Factory Installed Option Economizer Ov Motor Econ/OvMtr TCI Econ/TCI TXV TXV/OvMtr TXV/OvMtr/Econ TXV/Econ Power Supply 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 Capacity Cooling (BTUH) 189,000 189,000 189,000 189,000 189,000 189,000 189,000 189,000 189,000 189,000 189,000 189,000 189,000 189,000 189,000 189,000 189,000 189,000 189,000 189,000 189,000 189,000 189,000 189,000 189,000 189,000 189,000 189,000 EER 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 Uncrated Dimensions (in.) H W L 54 86 123 54 86 123 54 86 123 54 86 123 54 86 123 54 86 123 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 Mfg. Shipping Plant Weight CK/001 2309 CK/001 2444 CK/001 2384 CK/001 2519 CK/001 2310 CK/001 2445 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 2309 2384 2519 2444 2464 2599 2539 2674 2309 2444 2384 2519 2310 2445 2309 2384 2519 2444 2464 2599 2539 2674
TFD181C30MC Reheat Coil TFD181C30NC Econ/Reheat Coil TFD181C30PC Ov Mtr/Reheat Coil TFD181C30RC Econ/Ov Mtr/Reheat Coil TCD181C400C TCD181C40AC TCD181C40BC TCD181C40CC TCD181C40FC TCD181C40GC TCD181C40HC TCD181C40JC TCD181C40KC TCD181C40LC Economizer Ov Motor Econ/OvMtr TCI Econ/TCI TXV TXV/OvMtr TXV/OvMtr/Econ TXV/Econ
TFD181C40MC Reheat Coil TFD181C40NC Econ/Reheat Coil TFD181C40PC Ov Mtr/Reheat Coil TFD181C40RC Econ/Ov Mtr/Reheat Coil
PC 73
Mfg. Shipping Plant Weight CK/001 2309 CK/001 2444 CK/001 2384 CK/001 2519 CK/001 2310 CK/001 2445 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 2309 2384 2519 2444 2464 2599 2539 2674
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Liquid line drier Operating charge of R-22 Short orifice refrigerant control Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Trane 3-D scroll compressors Low pressure switches Dedicated horizontal and downflow designs Single side access Single point power for electric heat Complete line of optional electric heaters Quick-access panels with handles Sloped sheet metal drain pan Internally enhanced coil tubing Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 5 year compressor warranty Optional extended warranties
PC 74
PC 75
Uncrated Dimensions (in.) Mfg. Shipping H W L Plant Weight 54 86 123 CK/001 2380 54 86 123 CK/001 2455 54 86 123 CK/001 2381 54 54 54 54 54 54 86 86 86 86 86 86 123 123 123 123 123 123 CK/001 2380 CK/001 2455 CK/001 2381 CK/001 2380 CK/001 2455 CK/001 2381
TCH211C400C TCH211C40BC Ov Motor TCH211C40FC TCI TCH211CW00C TCH211CW0BC Ov Motor TCH211CW0FC TCI
Specifications: Downflow
Factory Model Installed Number Option TCD211C300C TCD211C30AC Economizer TCD211C30BC Ov Motor TCD211C30CC Econ/OvMtr TCD211C30FC TCI TCD211C30GC Econ/TCI TCD211C30HC TXV TCD211C30JC Econ/OvMtr TCD211C30KC TXV/OvMtr/Econ TCD211C30LC TXV/Econ TCD211C400C TCD211C40AC Economizer TCD211C40BC Ov Motor TCD211C40CC Econ/OvMtr TCD211C40FC TCI TCD211C40GC Econ/TCI TCD211C40HC TXV TCD211C40JC Econ/OvMtr TCD211C40KC TXV/OvMtr/Econ TCD211C40LC TXV/Econ TCD211CW00C TCD211CW0AC Economizer TCD211CW0BC Ov Motor TCD211CW0CC Econ/OvMtr TCD211CW0FC TCI TCD211CW0GC Econ/TCI Power Supply 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 Capacity Cooling (BTUH) 220,000 220,000 220,000 220,000 220,000 220,000 220,000 220,000 220,000 220,000 220,000 220,000 220,000 220,000 220,000 220,000 220,000 220,000 220,000 220,000 220,000 220,000 220,000 220,000 220,000 220,000 EER 11.00 11.00 11.00 11.00 11.00 11.00 11.00 11.00 11.00 11.00 11.00 11.00 11.00 11.00 11.00 11.00 11.00 11.00 11.00 11.00 11.00 11.00 11.00 11.00 11.00 11.00 Uncrated Dimensions (in.) Mfg. Shipping H W L Plant Weight 54 86 123 CK/001 2364 54 86 123 CK/001 2499 54 86 123 CK/001 2439 54 86 123 CK/001 2574 54 86 123 CK/001 2365 54 86 123 CK/001 2500 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 2364 2499 2439 2574 2364 2499 2439 2574 2365 2500 2364 2499 2439 2574 2364 2499 2439 2574 2365 2500
PC 76
Uncrated Dimensions (in.) Mfg. Shipping H W L Plant Weight 54 86 123 CK/001 2364 54 86 123 CK/001 2499 54 86 123 CK/001 2439 54 86 123 CK/001 2574 Single point power for electric heat Complete line of optional electric heaters Quick-access panels with handles Sloped sheet metal drain pan Internally enhanced coil tubing Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 5 year compressor warranty
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Short orifice refrigerant control Liquid line drier Operating charge of R-22 Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Trane 3-D scroll compressors Low pressure switches Dedicated horizontal and downflow designs Single side access
PC 77
Mfg. Shipping Plant Weight CK/001 2470 CK/001 2445 CK/001 2471 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 2470 2445 2471 2470 2445 2471
Specifications: Downflow
Model Number TCD241C300C TCD241C30AC TCD241C30BC TCD241C30CC TCD241C30FC TCD241C30GC TCD241C30HC TCD241C30JC TCD241C30KC TCD241C30LC TFD241C30MC TFD241C30NC TFD241C30PC TFD241C30RC TCD241C400C TCD241C40AC TCD241C40BC TCD241C40CC TCD241C40FC TCD241C40GC TCD241C40HC TCD241C40JC TCD241C40KC TCD241C40LC TFD241C40MC TFD241C40NC TFD241C40PC TFD241C40RC Factory Installed Option Economizer Ov Motor Econ/OvMtr TCI Econ/TCI TXV TXV/OvMtr TXV/OvMtr/Econ TXV/Econ Reheat Coil Econ/Reheat Coil Ov Mtr/Reheat Coil Econ/Ov Mtr/Reheat Coil Economizer Ov Motor Econ/OvMtr TCI Econ/TCI TXV TXV/OvMtr TXV/OvMtr/Econ TXV/Econ Reheat Coil Econ/Reheat Coil Ov Mtr/Reheat Coil Econ/Ov Mtr/Reheat Coil Power Supply 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 Capacity Cooling (BTUH) 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 EER 10.6 10.6 10.6 10.6 10.6 10.6 10.6 10.6 10.6 10.6 10.6 10.6 10.6 10.6 10.6 10.6 10.6 10.6 10.6 10.6 10.6 10.6 10.6 10.6 10.6 10.6 10.6 10.6 Uncrated Dimensions (in.) H W L 54 86 123 54 86 123 54 86 123 54 86 123 54 86 123 54 86 123 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 Mfg. Shipping Plant Weight CK/001 2454 CK/001 2589 CK/001 2529 CK/001 2664 CK/001 2455 CK/001 2590 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 2454 2529 2664 2589 2609 2744 2684 2819 2454 2589 2529 2664 2455 2590 2454 2529 2664 2589 2609 2744 2684 2819
PC 78
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Liquid line drier Operating charge of R-22 Short orifice refrigerant control Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Trane 3-D scroll compressors Low pressure switches Dedicated horizontal and downflow designs Single side access Single point power for electric heat Complete line of optional electric heaters Quick-access panels with handles Sloped sheet metal drain pan Internally enhanced coil tubing Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 1 year compressor warranty Optional extended warranties
PC 79
Mfg. Shipping Plant Weight CK/001 2476 CK/001 2477 CK/001 CK/001 CK/001 CK/001 2476 2477 2476 2477
Specifications: Downflow
Factory Model Installed Number Option TCD301C300C TCD301C30AC Economizer TCD301C30FC TCI TCD301C30GC Econ/TCI TCD301C30HC TXV TCD301C30LC TXV/Econ TCD301C400C TCD301C40AC Economizer TCD301C40FC TCI TCD301C40GC Econ/TCI TCD301C40HC TXV TCD301C40LC TXV/Econ TCD301CW00C TCD301CW0AC Economizer TCD301CW0FC TCI TCD301CW0GC Econ/TCI TCD301CW0HC TXV TCD301CW0LC TXV/Econ Power Supply 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 Capacity Cooling (BTUH) 300,000 300,000 300,000 300,000 EER 10.4 10.4 10.4 10.4 10.4 10.4 10.4 10.4 10.4 10.4 10.4 10.4 10.4 10.4 10.4 10.4 10.4 10.4 Uncrated Dimensions (in.) H W L 54 86 123 54 86 123 54 86 123 54 86 123 54 54 54 54 54 54 54 54 54 54 54 54 54 54 86 86 86 86 86 86 86 86 86 86 86 86 86 86 123 123 123 123 123 123 123 123 123 123 123 123 123 123 Mfg. Shipping Plant Weight CK/001 2460 CK/001 2595 CK/001 2461 CK/001 2596 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 2460 2595 2460 2595 2461 2596 2460 2595 2460 2595 2461 2596 2460 2595
208-230/3/60 300,000 208-230/3/60 300,000 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 300,000 300,000 300,000 300,000 300,000 300,000 300,000 300,000 300,000 300,000 300,000 300,000
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Liquid line drier Operating charge of R-22
Short orifice refrigerant control Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Trane 3-D scroll compressors Low pressure switches Dedicated horizontal and downflow designs Single side access Single point power for electric heat Complete line of optional electric heaters PC 80
Quick-access panels with handles Sloped sheet metal drain pan Internally enhanced coil tubing Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 1 year compressor warranty Optional extended warranties
PC 81
Shipping Weight 2
235 32 75 135 110 50/60 1 95 95 95 90 90 90 90 90 15 15 10 2 1 1 1 1 1 1
Motorized Outside Air Damper Downflow Economizer with Barometric Relief Horizontal Economizer
BAYGARD045A
BAYSTAT023 BAYPWRX029A BAYPWRX030A BAYPWRX031A
TC*181-301C
BAYECON090A,092A, BAYDMPR058A TCD181-301C3 TCD181-301C4 TCD181-301CW TCH/D211-241CW TCD/TCH181C TCH/D181CW TCD211-241C3 TCH211-241C3 TCD211-241C4 TCH211-241C4 TCD/TCH211-241C TCD/TCH301C TCD/TCH301C TCD181-301C TCH181-301C BAYECON090A,092A TCD181-301C/TCH181-301C BAYECON090A,092A BAYECON090A,092A TCD181-301C/TCH181-301C BAYECON090A,092A BAYDMPR058A TC*181-301C
CK/001
CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001
3 2 2 8 8 5 5
BAYLOAM023A
BAYTUBE008A BAYTUBE009A
CK/001
CK/001 CK/001
3
1 1
BAYVNOR002B
CK/001
1 For downflow use only. Cannot be adapted for horizontal units. 2 Kits contain all necessary parts to achieve desired level of enthalpy control. 3 Must be used with either field or factory installed TCI (Trane Communications Interface). 4 High static drives and oversized motors are mutually exclusive. Do not combine. 5Used for true discharge air sensing in both heating and cooling models. Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B). 6 Clarksville Manufacturing has a no-return policy for this roof curb. 7 BAYABRD002B is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS005A), Fan Fail Switch (BAYDFPS006A), Discharge Air Sensing Kit (BAYTUBE008A or BAYTUBE009A), Frostat (BAYLOAM023A), Ventilation Override (BAYVNOR002B). 8 Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B).
PC 82 Effective date: January 1, 2007
12 1/2 25 Ton
High Efficiency Zone Sensors: (Micro Thermostats to be used with Micro Units)
Model Number BAYSENS006B BAYSENS008B BAYSENS010B BAYSENS019C BAYSENS013C1 BAYSENS014C1 BAYSENS017B BAYSENS032A3 BAYSENS035A3 BAYMTPL003B BAYMTPL004B BAYCLCK001A2 BAYSTAT050A BAYSTAT052A BAYSTAT053A Description Single Setpoint Manual Changeover Dual Setpoint Manual or Auto Changeover Dual Setpoint Man. or Auto Changeover with System Function Lights Programmmable Night Setback w/System Function Lights Room Sensor w/ Override Button Room Sensor w/ Temp. Adjustment And Override Remote Room Sensor Dual Thermistor Remote Zone Sensor Digital Display Zone Sensor Retrofit Wall Cover Plate Kit 7.25"x6.0" Retrofit Wall Cover Plate Kit 4.75"x4.75" Electronic Time Clock for up to 4 units 2Htg/2Clg Digital Display Programmable Thermostat 2Htg/2Clg Digital Display Programmable "TOUCHSCREEN" Thermostat 3Htg/2Clg Digital Display Programmable Thermostat with Relative Humidity Sensing Built-In 3Htg/2Clg Digital Display Thermostat Return Air Remote Sensor Wall Mounted Remote Sensor
TM
Packaged Cooling
Used with TC*151-301 TC*151-301 TC*151-301 TC*151-301 TC*151-301 TC*151-301 BAYSENS006B, 008B, 010B & 019C TC*151-301 TC*151-301 BAYSENS019C BAYSENS006,008,010B, 017B & 013,014C BAYSENS006B,008B, 010B TC*151-301 TC*151-301
Mfg. Shipping Plant Weight CK/001 1 CK/001 1 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 1 1 1 1 1 1 1 1
1 1 1 1 1
TC*151-301 CK/001 (with Dehumidification Option) TC*151-301 CK/001 BAYSTAT050A, 052A,053A CK/001 BAYSTAT050A, 052A,053A CK/001
1 Used with Integrated Comfort Systems, any unit type. These sensors do not work with TCM. Consult BASD Marketing for them. 2 See Accessory IOM for operational characteristics. 3 Functional only with ReliaTel controls.
* Either horizontal or downflow models.
1 1 1
Controls:
Model Number BAYCO2K002B BAYCO2K004B BAYICSI004B BAYLTCI003B Description CO2 Sensor Kit, Wall Mounted CO2 Sensor Kit, Duct Mounted Field Installed TCI (Trane Communication Interface) LonTalk Interface Used with TC*151-301 w/Economizer TC*151-301 w/Economizer TC*151-301 TC*151-301 Mfg. Plant CK/001 CK/001 CK/001 CK/001 Shipping Weight 3 3.5 1 1
PC 83
E E 0
9 0
A A A
PC 84
1 All units require either a power cord or hard wire kit to power the unit 2 The Hydronic chassis W ships with no electric heat and no plastic front cover 3 All 265volt Hydronic chassis W require subbase, fuses and socket.
Features:
Exclusive patent pending Dehumidification Control provides up to 30% more moisture removal Flexible digital Interface provides wall or unit mounted control adjustment. Wall mounted Interface uses 2 unpolarized wires for connection Plug and Play display means on demand commissioning algorithm and automatic start-up delay The Universal Heater as a standard option means "Everything is stocked and ready to ship" Defrost Control - All units are equipped with heat pump control algorithm that prevents freezing of the condenser, while optimizing comfort
PC 85
Option 2.
Option 2.
PC 86
1 Contact TNDC- St Louis on special color grille. 2 To be ordered for all installations except where existing wall sleeves are used. 3 Used when a subbase is not required, but additional 4 5 6
7 Required when using a Hard wire kit. 8 The Power switch can be installed on the hard wire 9 0 q w
support and leveling is needed. The adjusting screw can be extended 2 inches with maximum distance from the bottom of the wall sleeve to screw base of 5 inches and a minimum distance of 3 inches. Attaches to wall sleeve for controlled indoor or outdoor disposal of condensate to a field supplied dian system. All PTAC units required a power cord or hard wire kit to power the unit. If 265V in addition to the power cord a universal subbase and socket for subbase are required. For a 230/208V units require the power cord and its optional the subbase and socket. This kit provides convenient space to make electrical connection to building wiring. Includes flexible conduit, and wire to make connection from unit chassis. The connectors for Hard wire kit need to be ordered for this Hard wire kit accesory.
junction box and provides a way to shut on and off the PTAC unit. Also its an optional accessory when using the Power Cord to power the PTAC unit. Check local codes for approval. Provides a space to tie into building, wiring and also includes a receptacle to plug unit into. Gives additional leveling and support capabilities. Provides a place for fuses, circuit breaker or mechanical disconnect to be mounted. (30A is for units. All subbases require a socket. The Circuit Breaker can be installed on front of subbase and provides over current protection and means of shutting unit on and off. Using the field installed, permanent, cleanable filters will keep debris off the coil and out of the air. Unit
e r t
will operate more efficiently if filters are changed regularly. All PTAC units require either a Display module or a wall mounted Thermostat to operate the unit. If Wall mounted controls the PTAC unit will require a Escutcheon cover to be mounted on the unit. This escutcheon cover should be ordered whenever the display module is wall mounted or a thermostat or third party provider unit controls are ordered. This escutcheon includes a control cover plate, that will cover the normal unit mounted nomenclatue. Al Hydronic PTAC chassis come standard without a plastic front cover for use with a hot water kit. If unit is required to work with out heat and with out Hydronic kit the plastic front cover should be ordered.
PC 87
Features:
All steel louvers and cabinet for rugged, long lasting protection Stainless steel burners and heat exchanger for extra long life and safety Quiet operation delivers great inhome comfort with minimal sound Weather Beater Top contoured for great appearance and reinforced for strength Appliance grade finish of durable powder paint baked on both sides of the panels Exclusive Climatuff high efficiency compressor with internal overload protection High efficiency outdoor fan motor for quiet and reliable operation Composite Vortica blower provides better airflow and less sound while using less energy Spine Fin outdoor coil for long lasting performance and durability Right side electrical service for high and low voltage connections Rugged steel basepan features deep drawn duct connections and emergency drains Steeply sloped composite drainpan will empty fast and never rust Ships in horizontal configuration and converts quickly for downflow Optional filter rack kits fit inside the unit. Available for 1" or 2" media Non-bleed expansion valves on indoor and outdoor coils Direct drive multi-speed indoor blower motors Pressure taps easily accessed and protected inside compressor compartment Easy access liquid line tap inside compressor compartment Standard operation to 55F as manufactured Low ambient cooling to 0F with kit. UL approved and listed 5 year compressor and other parts limited warranty (Residential Use Only) Optional extended warranty
PG 1
L 49 49 49 49 59 59 59 59 59
Features:
All steel louvers and cabinet for rugged, long lasting protection Stainless steel burners and heat exchanger for extra long life and safety Quiet operation delivers great inhome comfort with minimal sound Weather Beater Top contoured for great appearance and reinforced for strength Appliance grade finish of durable powder paint baked on both sides of the panels Exclusive Climatuff high efficiency compressor with internal overload protection High efficiency outdoor fan motor for quiet and reliable operation Composite Vortica blower provides better airflow and less sound while using less energy Spine Fin outdoor coil for long lasting performance and durability Right side electrical service for high and low voltage connections Rugged steel basepan features deep drawn duct connections and emergency drains Steeply sloped composite drainpan will empty fast and never rust Ships in horizontal configuration and converts quickly for downflow Optional filter rack kits fit inside the unit. Available for 1" or 2" media Non-bleed expansion valves on indoor and outdoor coils PG 2 Direct drive multi-speed indoor blower motors Pressure taps easily accessed and protected inside compressor compartment Easy access liquid line tap inside compressor compartment Standard operation to 55F as manufactured Low ambient cooling to 0F with kit. UL approved and listed 10 year heat exchanger, 5 year compressor and other parts limited warranty (Residential Use Only) Optional extended warranty
Shipping Weight
74 74 50 65 85 85 1 2 6 8
Extended Warranties (1 yr - 5 yr - 10 yr See Extended Warranty Section) Controls See Comfort Controls Section BAYCURB050A Roof Curb (Flat Roof) BAYCURB051A Roof Curb (Flat Roof) BAYECON101A 0-100% Mod. Economizer w/Baro. Relief BAYECON102A 0-100% Mod. Economizer w/Baro. Relief BAYECON200A 0-100% Mod. Econ. - Horizontal BAYECON201A 0-100% Mod. Econ. - Horizontal BAYSTAT023 Remote Potentiometer BAYENTH001A Enthalpy Control (Solid State) BAYOSAH001A 0-25% Manual Fresh Air Damper BAYOSAH002A 0-25% Manual Fresh Air Damper BAYDMPR101A Motorized Fresh Air Damper BAYDMPR102A Motorized Fresh Air Damper BAYFLTR101A 1"-2" Filter Frame (20x25 filter not included) BAYFLTR201A 1"-2" Filter Frame (20x20,20x18 filters not included) BAYLPKT100A LP Conversion Kit - All 40K,120K YC models BAYLPKT101A LP Conversion Kit - All 64K, 96K YC models BAYLPKT102A LP Conversion Kit - All 75K YC models BAYLOAM011A Evaporator Defrost Control Kit BAYLOAM105A Low Ambient Control Kit BAYQSTK301A Quick Start Kit BAYCCHT101B Crankcase Heater - 230v - Recip
25 26
137 137 1 1
1347 1347
1 1
14 14
*YCC3018-036A *YCC3042-060A *YCC3018-036A *YCC3042-060A *YCC3018-036A *YCC3042-060A All Economizers All Economizers *YCC3018-036A *YCC3042-060A *YCC3018-036A *YCC3042-060A *YCC3018-036A *YCC3042-060A
BAYCCHT102B BAYCCHT404B BAYSQRD001A BAYSQRD002A BAYADAP050A BAYADAP051A BAYADAP052A BAYADAP053A BAYADAP054A BAYUTIL101A BAYUTIL102A BAYCOVR112A BAYCOVR118A BAYEXMK001A BAYEXMK002A BAYEXMK003A BAYLIFT002B
1 Must use filter frame when economizer/fresh air kit is used. 2 Ships knocked down. 3 Dry bulb control standard with economizer. 4 Downflow Only. 5 Full perimeter curb for 2/4YC*3018-036A. 6 Full perimeter curb for 2/4YC*3042-060A. 7 2-Stage thermostat provides additional energy savings if simultaneous economizer and compressor operation is expected. 8 It is the responsibility of the installing dealer to properly size the ductwork for each specific application. 9 BAYCOVR112,118A will not cover BAYSQRD002A applications
All 2/4YCC3 All 2/4YCC3 All 2/4YCC3 2YCC3024,30,42,48A1, 4YCC3018A1 Crankcase Heater - 230v - Scroll 2YCC3036A1, 4YCC3036,48,60A1/3 Crankcase Heater - 460v - Scroll 4YC*3036,48,60A4 16" Round Duct Adapter (2 Per Box) *YCC3018-036A FS/200 5 18" Round Duct Adapter (2 Per Box) *YCC3018-060A FS/200 3 Adapter Curb *YC*3018-036A to BAYCURB030,38 Adapter Curb *YC*3018-036A to BAYCURB033 Adapter Curb *YC*3042-060A to BAYCURB030,38 Adapter Curb *YC*3042-060A to BAYCURB033 Adapter Curb *YC*3042-060A to BAYCURB034 Roof Curb Utility Extension Kit *YCC3018-036A Roof Curb Utility Extension Kit *YCC3042-060A 12" Duct Shroud Covers Horizontal *YCC3018-060A 18" Duct Shroud Covers Horizontal *YCC3018-060A Extreme Condition Mounting Kit - All BAYCURB & BAYADAP Extreme Condition Mounting Kit - All BAYUTIL Extreme Condition Mounting Kit - All Slab Mounts Lifting Lug Kit All *YCC3 FS/200 5
6 6 2 2 2 5 5
8 8
9 9
PG 3
Features:
Architecturally integrated louvers and corner guards deliver durable protection, extra safety, and great looks Stainless steel burners and heat exchanger for extra long life and safety Weather Beater Top contoured for great appearance and reinforced for strength Ultra quiet operation provides bestin-class performance with barely noticeable sound levels Appliance grade finish of durable powder paint baked on both sides of the panels Exclusive Climatuff high efficiency compressor with internal overload protection Refrigerant line filter drier Ducted outdoor fan with a high efficiency motor for quiet and reliable operation Composite Vortica blower provides better airflow and less sound while using less energy Spine Fin outdoor coil for long lasting performance and durability Right side electrical service for high and low voltage connections Rugged steel basepan features deep drawn duct connections and emergency drains Steeply sloped composite drainpan will empty fast and never rust Ships in horizontal configuration and converts quickly for downflow Optional filter rack kits fit inside the unit. Available for 1" or 2" media Non-bleed expansion valves on indoor and outdoor coils Direct drive multi-speed indoor blower motors Pressure taps easily accessed and protected inside compressor compartment Easy access liquid line tap inside compressor compartment Standard operation to 55F as manufactured Low ambient cooling to 0F with kit. UL approved and listed 20 year heat exchanger, 10 year compressor, 10 year outdoor coil, and 5 year other parts limited warranty (Residential Use Only) Optional extended warranty
PG 4
L 51 51 51 51 61 61 61 61 61
Features:
Architecturally integrated louvers and corner guards deliver durable protection, extra safety, and great looks Stainless steel burners and heat exchanger for extra long life and safety Weather Beater Top contoured for great appearance and reinforced for strength Ultra quiet operation provides bestin-class performance with barely noticeable sound levels Appliance grade finish of durable powder paint baked on both sides of the panels Exclusive Climatuff high efficiency compressor with internal overload protection
Ducted outdoor fan with a high efficiency motor for quiet and reliable operation Composite Vortica blower provides better airflow and less sound while using less energy Spine Fin outdoor coil for long lasting performance and durability Right side electrical service for high and low voltage connections Rugged steel basepan features deep drawn duct connections and emergency drains Steeply sloped composite drainpan will empty fast and never rust Ships in horizontal configuration and converts quickly for downflow Refrigerant line filter drier Optional filter rack kits fit inside the unit. Available for 1" or 2" media PG 5
Non-bleed expansion valves on indoor and outdoor coils Direct drive multi-speed indoor blower motors Pressure taps easily accessed and protected inside compressor compartment Easy access liquid line tap inside compressor compartment Standard operation to 55F as manufactured Low ambient cooling to 0F with kit UL approved and listed 20 year heat exchanger, 10 year compressor, 10 year outdoor coil, and 5 year other parts limited warranty (Residential Use Only) Optional extended warranty
Shipping Weight
74 74 50 65 85 85 1 2 6 8
Extended Warranties (1 yr - 5 yr - 10 yr See Extended Warranty Section) Controls See Comfort Controls Section BAYCURB050A Roof Curb (Flat Roof) BAYCURB051A Roof Curb (Flat Roof) BAYECON101A 0-100% Mod. Economizer w/Baro. Relief BAYECON102A 0-100% Mod. Economizer w/Baro. Relief BAYECON200A 0-100% Mod. Econ. - Horizontal BAYECON201A 0-100% Mod. Econ. - Horizontal BAYSTAT023 Remote Potentiometer BAYENTH001A Enthalpy Control (Solid State) BAYOSAH001A 0-25% Manual Fresh Air Damper BAYOSAH002A 0-25% Manual Fresh Air Damper BAYDMPR101A Motorized Fresh Air Damper BAYDMPR102A Motorized Fresh Air Damper BAYFLTR101A 1"-2" Filter Frame (20x25 filter not included) BAYFLTR201A 1"-2" Filter Frame (20x20,20x18 filters not included) BAYLPKT100A LP Conversion Kit - All 40K,120K YC models BAYLPKT101A LP Conversion Kit - All 64K, 96K YC models BAYLPKT102A LP Conversion Kit - All 75K YC models BAYLOAM011A Evaporator Defrost Control Kit BAYLOAM105A Low Ambient Control Kit BAYQSTK301A Quick Start Kit BAYCCHT101B Crankcase Heater - 230v - Recip
25 26
137 137 1 1
1347 1347
1 1
14 14
*YCX3018-036A *YCX3042-060A *YCX3018-036A *YCX3042-060A *YCX3018-036A *YCX3042-060A All Economizers All Economizers *YCX3018-036A *YCX3042-060A *YCX3018-036A *YCX3042-060A *YCX3018-036A *YCX3042-060A
BAYCCHT102B BAYCCHT404B BAYSQRD001A BAYSQRD002A BAYADAP050A BAYADAP051A BAYADAP052A BAYADAP053A BAYADAP054A BAYUTIL101A BAYUTIL102A BAYCOVR112A BAYCOVR118A BAYEXMK001A BAYEXMK002A BAYEXMK003A BAYLIFT002B
1 Must use filter frame when economizer/fresh air kit is used. 2 Ships knocked down. 3 Dry bulb control standard with economizer. 4 Downflow Only. 5 Full perimeter curb for 2/4YC*3018-036A. 6 Full perimeter curb for 2/4YC*3042-060A. 7 2-Stage thermostat provides additional energy savings if simultaneous economizer and compressor operation is expected. 8 It is the responsibility of the installing dealer to properly size the ductwork for each specific application. 9 BAYCOVR112,118A will not cover BAYSQRD002A applications
All 2/4YCX3 All 2/4YCX3 All 2/4YCX3 2YCX3024,30,42,48A1, 4YCX3018A1 Crankcase Heater - 230v - Scroll 2YCX3036A1, 4YCX3036,48,60A1/3 Crankcase Heater - 460v - Scroll 4YCX3036,48,60A4 16" Round Duct Adapter (2 Per Box) *YCX3018-036A FS/200 5 18" Round Duct Adapter (2 Per Box) *YCX3018-060A FS/200 3 Adapter Curb *YCX3018-036A to BAYCURB030,38 Adapter Curb *YCX3018-036A to BAYCURB033 Adapter Curb *YCX3042-060A to BAYCURB030,38 Adapter Curb *YCX3042-060A to BAYCURB033 Adapter Curb *YCX3042-060A to BAYCURB034 Roof Curb Utility Extension Kit *YCX3018-036A Roof Curb Utility Extension Kit *YCX3042-060A 12" Duct Shroud Covers Horizontal *YCX3018-060A 18" Duct Shroud Covers Horizontal *YCX3018-060A Extreme Condition Mounting Kit - All BAYCURB & BAYADAP Extreme Condition Mounting Kit - All BAYUTIL Extreme Condition Mounting Kit - All Slab Mounts Lifting Lug Kit All *YCX3 FS/200 5
6 6 2 2 2 5 5
8 8
9 9
PG 6
L 64 65 65
Mfg. Shipping Plant Weight FS/200 588 FS/200 693 FS/200 723
Features:
Industry's highest efficiency -- up to 16.05 SEER Coil-Sav'R Lexan wrap-around grille Exclusive two-stage heating and cooling operation Two-stage gas furnace New side electrical service access for high and low voltage Powder paint and WeatherguardTM screws for a quality appearance that lasts Acousti-Curb for rooftop applications Exclusive dual Climatuff high efficiency compressors Exclusive Uni-Curb that fits all units Exclusive Comfort-RTM enhanced comfort setting for better humidity control in cooling mode Exclusive common cabinetry Exclusive Water-Shed no leak one piece base pan DuratuffTM outdoor plate fin coil Direct spark two-stage integrated ignition control Two-speed combustion blower Exclusive trim ring on top discharge fan grille Optional In-FilterTM filter rack fits inside unit Multi-speed direct drive blower motor to match two-stage heating/cooling Non-bleed indoor expansion valves Refrigerant line filter drier Two-speed high efficiency outdoor fan motor with polarized plug Ships for horizontal application; easily convertible to downflow UL listed Compressor IOL protection Standard operation to 45F as manufactured Low ambient cooling to 0F with accessories BAYLOAM011A and BAYLOAM323A Crankcase heater is applied (factory installed) 10-year limited compressor and outdoor coil warranty, 20-year limited heat exchanger warranty, 5-years on other parts (Residential Use Single Phase Only) Optional extended warranties
50% 50% Only if required 40% FIRST STAGE 25% Dehumidify Warm Air Heating Fast Coil Cooling Fast Coil Heating Enhanced Comfort 1 minute 7.5 minutes Enhanced Efficiency
50%
25%
OFF
OFF
COMPRESSOR OPERATION ON
PG 7
Accessories:
Model Number Description Used With Extended Warranties (1 yr - 5 yr - 10 yr See Extended Warranty Section) BAYCURB033A Roof Curb (Flat Roof)3 Acousti-Curb YCZ036F BAYCURB034A Roof Curb (Flat Roof)3 Acousti-Curb YCZ050,060F BAYINDK002A** Insulated Deck Pan for C Cabinet BAYCURB033A BAYINDK003A*** Insulated Deck Pan for D Cabinet BAYCURB034A BAYECON054B 0-100% Mod. Econ. w/Bar Relief2456 YCZ036F BAYECON055B 0-100% Mod. Econ. w/Bar Relief2456 YCZ050,060F BAYECON073A 0-100% Mod. Econ. - Horizontal246 YCZ-F Models BAYSTAT023 Remote Potentiometer BAYECON054B,055B BAYENTH001A Enthalpy Control (Solid State)4 YCZ-F Models BAYDMPR040A 0-25% Manual Fresh Air Damper2 YCZ036F BAYDMPR041A 0-25% Manual Fresh Air Damper2 YCZ050,060F BAYFLTR013A Filter Frame2(20x25x1" filter not incl) YCZ036F BAYFLTR014A Filter Frame2(3-10x24x1" filters not incl) YCZ050,060F BAYFLTR018A Filter Frame2(1-20x25x2" filters not incl) YCZ036F BAYFLTR019A Filter Frame2(2-16x25x2" filter not incl) YCZ050,060F BAYLOAM011A Evap. Defrost Control Kit1 YCZ-F Models BAYLPKT024B LP Conversion Kit YCZ-F Models BAYLPSS002A LP Conversion Kit with SS Burners YCZ-F Models BAYDUCT004A 12" Round Duct Adapters (2 Per Box) YCZ036F BAYDUCT005A 14" Round Duct Adapter (1 Per Box) YCZ050,060F BAYLIFT002B Lifting Lug Kit YCZ-F Models BAYASCT001 Anti-Short Cycle Timer YCZ-F Models BAY0SAC001A Outside Air Econo Controller YCZ-F Models
1 Low ambient cooling requires crankcase heater (BAYCCHT003A). 2 Must use filter frame when economizer/fresh air kit is used. 3 Ships knocked down. 4 Dry bulb control standard with economizer. 5 Downflow Only. 6 For low ambient applications, use this controller. 7 Requires subbase.
** Currently shipped with BAYCURB033A ***Currently shipped with BAYCURB034A
PG 8
Features:
Variable Speed ECM motor with ramped start and quiet operation Exclustive Comfort -RTM enhanced cooling/dehumidification mode (see chart) Two-stage gas heat for heating comfort Side electrical service access for high and low voltage Sloped composite no-rust drain pan All foil faced washable insulation Coil-Sav'R Lexan grille Exclusive trim ring on top discharge fan grille Powder paint and WeatherguardTM coated screws for a quality apperance that lasts Exclusive Climatuff high efficiency compressor Uni-Curb that fits all sizes 2-5 tons Common cabinetry across lines (G/E, Clg.) and across efficiency tiers Water-Shed no leak one piece base pan Two-stage direct spark integrated ignition control Two-speed combustion blower Ships for horizontal application; easily convertible to downflow Refrigerant line filter High efficiency outdoor fan motor with polarized plug UL Listed Compressor IOL protection Standard operations to 55F as manufactured Low ambient cooling to 0F with accessories BAYLOAM011A, BAYLOAM323A Optional In-FilterTM filter rack fits inside unit 10-year limited compressor and oudoor coil warranty, 20-year limited heat exchanger warranty, 5-years on other parts (Residential Use Single Phase Only) Optional extended warranties
VARIABLE
XL1400
SPEED
80%
FAN OPERATION (CFM)
Efficiency OFF
3 minutes OFF
COMPRESSOR OPERATION ON
PG 9
1 Must use filter frame when economizer/fresh air kit is used. 2 Ships knocked down. 3 Dry bulb control standard with economizer. 4 Downflow Only. 5 Use low ambient motor on YCY024-042G. Not required on YCY048-060G1 6 2-Stage thermostat provides additional energy savings if simultaneous economizer and compressor operation is expected. 7 Full perimeter curb for YCY024,042G 8 Full perimeter curb for YCY048,060G 9 It is the responsibility of the installing dealer to properly size the ductwork for each specific application 0 Low ambient cooling requires crankcase heater (BAYCCHT***A)
* Currently shipped with BAYCURB038A ** Currently shipped with BAYCURB033A ***Currently shipped with BAYCURB034A
FS/200 FS/200 FS/200 FS/200 FS/200 FS/200 FS/200 FS/200 FS/200 CK/000 FS/200 FS/200 FS/200 FS/200 FS/200 FS/200 FS/200 TY FS/200 FS FS/200 FS/200 FS/200 FS/200 FS/200 FS/200 FS/200 FS/200
74 74 88 100 28 30 50 65 85 1 2 6 8 6 9 9 9 5 5 20 2 10 5 3 5 1 2 2
PG 10
Model Nomenclature
Y 1
S 2
C 036 A 3 4,5,6 7
3 8
R B A ** C 0 0 0 A 1 9 10 11 12,13 14 15 16 17 18 19
E = Economizer, Reference Enthalpy 0-100% without Barometric Relief12 F = Economizer, Reference Enthalpy 0-100% with Barometric Relief12 G = Economizer, Comparative Enthalpy 0-100% without Barometric Relief12 H = Economizer, Comparative Enthalpy 0-100% with Barometric Relief12 DIGIT 15 - Supply Fan/Drive Type/Motor 0 = Standard Driveu 1 = Oversized Motor 2 = Optional Belt Drive Motor DIGIT 16 - Hinged Service Access & Filters 0 = Standard Panels & Standard Filters A = Hinged Access Panels & Standard Filters B = Standard Panels & 2" Pleated Filters C = Hinged Access Panels & 2" Pleated Filters DIGIT 17 - Condenser Coil Protection 0 = Standard Coil 1 = Standard Coil with Hail guard 2 = Black Epoxy Coated Condenser Coil 3 = Black Epoxy Coated Condenser Coil with Hail Guard 4 = CompleteCoat Condenser Coil 5 = CompleteCoat Condenser Coil with Hail Guard
DIGIT 1 - Unit Function T = DX Cooling Y = DX Cooling, Gas Heat DIGIT 2 - Efficiency S = Standard Efficiency H = High Efficiencyo DIGIT 3 - Airflow C = Convertible DIGITS 4,5,6 - Nominal Gross Cooling Capacity (MBh) 036 = 3 Ton 048 = 4 Ton 060 = 5 Ton 072 = 6 Ton 090 = 7.5 Ton, Single Compressor 092 = 7.5 Ton, Dual Compressors 102 = 8.5 Ton 120 = 10 Ton DIGIT 7 - Major Design Sequence A = First DIGIT 8 - Unit Voltage 3 = 208-230/60/3 4 = 460/60/3 W = 575/60/3 K = 380/60/3 DIGIT 9 - Unit Controls E = Electromechanical R = ReliaTel DIGIT 10 - Heating Capacity Note: Sequence may be any letter A through Z, or any digit 1 through 9. 0 = No Electric Heater B = 6 kw (3 phase) C = 9 kw (3 phase) E = 12 kw (3 phase) G = 18 kw (3 phase) J = 23 kw (3 phase) K = 27 kw (3 phase) N = 36 kw (3 phase) P = 54 kw (3 phase) Note: Applicable to Digit 1, Y models only. L = Low M = Medium H = High X = Low, Stainless Steel Heat Exchanger Y = Medium, Stainless Steel Heat Exchanger Z = High, Stainless Steel Heat Exchanger DIGIT 11 - Minor Design Sequence A = First Sequence DIGIT 12,13 - Service Sequence ** = Factory Assigned DIGIT 14 - Fresh Air Selection 0 = No Fresh Air A = Manual Outside Air Damper 0-50%e B = Motorized Outside Air Damper 0-50% C = Economizer, Dry Bulb 0-100% without Barometric Relief2 D = Economizer, Dry Bulb 0-100% with Barometric Relief2
A = Thermal Expansion Valve (TXV) B = Dehumidification (Hot Gas Reheat Coil)ri DIGIT 23 - Refrigeration Controls 0 = No Refrigeration Control 1 = High Pressure Control16 2 = Frostat5 3 = Crankcase Heatery 4 = High Pressure Control16 and Frostat5 5 = High Pressure Control16 and Crankcase Heatery 6 = Frostat5 and Crankcase Heater6y 7 = High Pressure Control,16 Frostat5 and Crankcase Heater6y DIGIT 24 - Smoke Detector 0 = No Smoke Detector A = Return Air Smoke Detector89 B = Supply Air Smoke Detector C = Supply and Return Air Smoke Detectors9
DIGIT 25 - Monitoring Controls1 0 = No Monitoring Control0 1 = Clogged Filter Switch0 2 = Fan Failure Switch0 3 = Discharge Air Sensing Tube0 4 = Clogged Filter Switch and Fan Fail Switch0 5 = Clogged Filter Switch and Discharge Air Sensing Tube0 DIGIT 18 - Through the Base Provisions Models 6 = Fan Fail Switch and Discharge Air Sensing Tube0 Note: (Applicable to Digit 1, T or Y models) 7 = Clogged Filter and Fan Fail Switches 0 = No Through the Base Provisions and Discharge Air Sensing Tube0 A = Through the Base Electrict 8 = Novar Return Air Sensorq Note: (Applicable to Digit 1, Y models only) Model Number Notes B = Through the Base Gas Piping 1 Not available with electromechanical unit controls. C = Through the Base Electric and Gas 2 Economizer with Barometric Relief is for downflow Pipingw configured units only. Order Economizer without DIGIT 19 - Disconnect/Circuit Breaker/ Phase Monitor (3 phase only) 0 = No Disconnect or Circuit Breaker 1 = Non-Fused Disconnectt 2 = Circuit Breakert 3 = Phase Monitor 4 = Phase Monitor & Non-Fused Disconnect Switch 5 = Phase Monitor & Circuit Breaker DIGIT 20 - Convenience Outlet 0 = No Convenience Outlet A = Unpowered Convenience Outlet B = Powered Convenience Outlet (3 phase only)3 DIGIT 21 - Communications Options1 0 = No Communications Interface 1 = Trane Communications Intertace 2 = LonTalk Communications Interface 3 = Novar 2024 Controls 4 = Novar 3051 Controls DIGIT 22 - Refrigeration System Option 0 = Standard Refrigeration System4
3 4 5 6 7 8 9 0 q w e r t y u i o
Barometric Relief for horizontal configuration. Barometric Relief for horizontal configured units must be ordered as field installed accessory. Requires use of Disconnect or Circuit Breaker. Standard refrigeration metering device short orifice. Frostat cannot be field installed in electro-mechanical units. High Pressure control is standard on 3-phase units with scrol compressors and in 3 ton standard efficiency units. Not available with High Temperature Stat accessory. The return air smoke detector may not fit up or work properly on the Precedent units when used in conjunction with 3rd party accessories such as bolt on heat wheels, economizers and power exhaust. Do not order the return air smoke detectors when using this type of accessory. Return Air Smoke Detector cannot be ordered with Novar Controls. These options are standard when ordering Novar Controls. This option is used when ordering Novar Controls. Includes gas piping and shutoff (field assembly required). The manual outside air damper will ship factory supplied within the unit, but must be field installed. Requires selection of 2 Pleated Filters (option B or C) for Digit 16. Through the base electric required when ordering disconnect/circuit breaker options. Crankcase heaters are standard on 3 ton standard efficiency and 7.5 ton single compressor units. Direct Drive (3-5 tons); Belt Drive (6-10 tons) Not available on 6 ton units and all single phase or standard efficiency. Available on 6-10 tons only.
PG 11
3 5 Ton YSC036-060A
Gross Capacity Capacity Heating Model Power Cooling Output Number Supply (BTUH) (BTUH) SEER 10th Digit = Low Heat, Standard Heat Exchanger YSC036A3*L 208-230/60/3 37,400 48,000 10.7 YSC048A3*L 208-230/60/3 49,200 48,000 10.0 YSC060A3*L 208-230/60/3 63,100 48,000 10.2 YSC036A4*L YSC048A4*L YSC060A4*L YSC036AW*L YSC048AW*L YSC060AW*L 460/60/3 460/60/3 460/60/3 575/60/3 575/60/3 575/60/3 37,400 49,200 63,100 37,400 49,200 63,100 48,000 48,000 48,000 48,000 48,000 48,000 10.7 10.0 10.2 10.7 10.0 10.2
Table 1 Main Assembly 3-5 Ton Standard Efficiency (Digits 1-8 & Digit 10)
10th Digit = Medium Heat, Standard Heat Exchanger YSC036A3*M 208-230/60/3 37,400 64,000 YSC048A3*M 208-230/60/3 49,200 64,000 YSC060A3*M 208-230/60/3 63,100 64,000 YSC036A4*M YSC048A4*M YSC060A4*M YSC036AW*M YSC048AW*M YSC060AW*M 460/60/3 460/60/3 460/60/3 575/60/3 575/60/3 575/60/3 37,400 49,200 63,100 37,400 49,200 63,100 64,000 64,000 64,000 64,000 64,000 64,000
32 32 36 32 32 36 36 36 36
43 43 43 43 43 43 43 43 43
69 69 69 69 69 69 69 69 69
LH LH LH LH LH LH LH LH LH
10th Digit = High Heat, Standard Heat Exchanger YSC036A3*H 208-230/60/3 37,400 96,000 YSC048A3*H 208-230/60/3 49,200 96,000 YSC060A3*H 208-230/60/3 63,100 104,000 YSC036A4*H YSC048A4*H YSC060A4*H YSC036AW*H YSC048AW*H YSC060AW*H 460/60/3 460/60/3 460/60/3 575/60/3 575/60/3 575/60/3 37,400 49,200 63,100 37,400 49,200 63,100 96,000 96,000 104,000 96,000 96,000 104,000
32 32 36 32 32 36 36 36 36
43 43 43 43 43 43 43 43 43
69 69 69 69 69 69 69 69 69
LH LH LH LH LH LH LH LH LH
PG 12
6 10 Ton YSC072-120A
Table 1 Main Assembly 6-10 Ton Standard Efficiency (Digits 1-8 & Digit 10)
Gross Capacity Capacity Heating Model Power Cooling Output Number Supply (BTUH) (BTUH) 10th Digit = Low Heat, Standard Heat Exchanger YSC072A3*L 208-230/60/3 72,000 64,800 YSC090A3*L 208-230/60/3 90,000 97,200 YSC092A3*L 208-230/60/3 90,000 97,200 YSC102A3*L 208-230/60/3 105,000 97,200 YSC120A3*L 208-230/60/3 117,000 121,500 YSC072A4*L YSC090A4*L YSC092A4*L YSC102A4*L YSC120A4*L YSC072AW*L YSC090AW*L YSC092AW*L YSC102AW*L YSC120AW*L 460/60/3 460/60/3 460/60/3 460/60/3 460/60/3 575/60/3 575/60/3 575/60/3 575/60/3 575/60/3 72,000 90,000 90,000 105,000 117,000 72,000 90,000 90,000 105,000 117,000 64,800 97,200 97,200 97,200 121,500 64,800 97,200 97,200 97,200 121,500 Mfg. Plant LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH Shipping Weight 822 907 909 986 1074 822 907 909 986 1074 822 907 909 986 1074
EER 10.1 10.3 10.3 10.1 10.3 10.1 10.3 10.3 10.1 10.3 10.1 10.3 10.3 10.1 10.3
10th Digit = Medium Heat, Standard Heat Exchanger YSC072A3*M 208-230/60/3 72,000 97,200 YSC090A3*M 208-230/60/3 90,000 121,500 YSC092A3*M 208-230/60/3 90,000 121,500 YSC102A3*M 208-230/60/3 105,000 121,500 YSC120A3*M 208-230/60/3 117,000 162,000 YSC072A4*M YSC090A4*M YSC092A4*M YSC102A4*M YSC120A4*M YSC072AW*M YSC090AW*M YSC092AW*M YSC102AW*M YSC120AW*M 460/60/3 460/60/3 460/60/3 460/60/3 460/60/3 575/60/3 575/60/3 575/60/3 575/60/3 575/60/3 72,000 90,000 90,000 105,000 117,000 72,000 90,000 90,000 105,000 117,000 97,200 121,500 121,500 121,500 162,000 97,200 121,500 121,500 121,500 162,000
10.1 10.3 10.3 10.1 10.3 10.1 10.3 10.3 10.1 10.3 10.1 10.3 10.3 10.1 10.3
41 41 41 47 47 41 41 41 47 47 41 41 41 47 47
53 53 53 53 53 53 53 53 53 53 53 53 53 53 53
89 89 89 89 89 89 89 89 89 89 89 89 89 89 89
LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH
822 907 909 986 1074 822 907 909 986 1074 822 907 909 986 1074
PG 13
6 10 Ton YSC072-120A
Table 1 Main Assembly 6-10 Ton Standard Efficiency (Digits 1-8 & Digit 10) - Continued
Gross Capacity Capacity Heating Model Power Cooling Output Number Supply (BTUH) (BTUH) 10th Digit = High Heat, Standard Heat Exchanger YSC072A3*H 208-230/60/3 72,000 121,500 YSC090A3*H 208-230/60/3 90,000 162,000 YSC092A3*H 208-230/60/3 90,000 162,000 YSC102A3*H 208-230/60/3 105,000 162,000 YSC120A3*H 208-230/60/3 117,000 205,500 YSC072A4*H YSC090A4*H YSC092A4*H YSC102A4*H YSC120A4*H YSC072AW*H YSC090AW*H YSC092AW*H YSC102AW*H YSC120AW*H 460/60/3 460/60/3 460/60/3 460/60/3 460/60/3 575/60/3 575/60/3 575/60/3 575/60/3 575/60/3 72,000 90,000 90,000 105,000 117,000 72,000 90,000 90,000 105,000 117,000 121,500 162,000 162,000 162,000 205,500 121,500 162,000 162,000 162,000 205,500 Mfg. Plant LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH Shipping Weight 822 907 909 986 1074 822 907 909 986 1074 822 907 909 986 1074
EER 10.1 10.3 10.3 10.1 10.3 10.1 10.3 10.3 10.1 10.3 10.1 10.3 10.3 10.1 10.3
PG 14
3 5 Ton YHC036-060A
Gross Capacity Capacity Heating Model Power Cooling Output Number Supply (BTUH) (BTUH) SEER 10th Digit = Low Heat, Standard Heat Exchanger YHC036A3*L 208-230/60/3 38,000 48,000 12.5 YHC048A3*L 208-230/60/3 49,800 48,000 11.9 YHC060A3*L 208-230/60/3 62,400 48,000 12.2 YHC036A4*L YHC048A4*L YHC060A4*L YHC036AW*L YHC048AW*L YHC060AW*L 460/60/3 460/60/3 460/60/3 575/60/3 575/60/3 575/60/3 38,000 49,800 62,400 38,000 49,800 62,400 48,000 48,000 48,000 48,000 48,000 48,000 12.5 11.9 12.2 12.5 11.9 12.2
Table 2 Main Assembly 3-5 High Efficiency (Digits 1-8 & Digit 10)
10th Digit = Medium Heat, Standard Heat Exchanger YHC036A3*M 208-230/60/3 38,000 64,000 YHC048A3*M 208-230/60/3 49,800 64,000 YHC060A3*M 208-230/60/3 62,400 64,000 YHC036A4*M YHC048A4*M YHC060A4*M YHC036AW*M YHC048AW*M YHC060AW*M 460/60/3 460/60/3 460/60/3 575/60/3 575/60/3 575/60/3 38,000 49,800 62,400 38,000 49,800 62,400 64,000 64,000 64,000 64,000 64,000 64,000
32 32 36 32 32 36 36 36 36
43 43 43 43 43 43 43 43 43
69 69 69 69 69 69 69 69 69
LH LH LH LH LH LH LH LH LH
10th Digit = High Heat, Standard Heat Exchanger YHC036A3*H 208-230/60/3 38,000 96,000 YHC048A3*H 208-230/60/3 49,800 96,000 YHC060A3*H 208-230/60/3 62,400 104,000 YHC036A4*H YHC048A4*H YHC060A4*H YHC036AW*H YHC048AW*H YHC060AW*H 460/60/3 460/60/3 460/60/3 575/60/3 575/60/3 575/60/3 38,000 49,800 62,400 38,000 49,800 62,400 96,000 96,000 104,000 96,000 96,000 104,000
32 32 36 32 32 36 36 36 36
43 43 43 43 43 43 43 43 43
69 69 69 69 69 69 69 69 69
LH LH LH LH LH LH LH LH LH
PG 15
6 10 Ton YHC072-120A
Gross Capacity Cooling (BTUH) Capacity Heating Output (BTUH)
64,800 97,200 97,200 121,500 64,800 97,200 97,200 121,500 64,800 97,200 97,200 121,500
Table 2 Main Assembly 6-10 Ton High Efficiency (Digits 1-8 & Digit 10) - Continued
Model Number Power Supply Mfg. Plant
LH LH LH LH LH LH LH LH LH LH LH LH
EER
11.4 11.4 11.4 11.3 11.4 11.4 11.4 11.3 11.4 11.4 11.4 11.3
Shipping Weight
859 909 1044 1147 859 909 1044 1147 859 909 1044 1147
10th Digit = Low Heat, Standard Heat Exchanger YHC072A3*L 208-230/60/3 72,000 YHC092A3*L 208-230/60/3 90,000 YHC102A3*L 208-230/60/3 102,000 YHC120A3*L 208-230/60/3 116,000 YHC072A4*L YHC092A4*L YHC102A4*L YHC120A4*L YHC072AW*L YHC092AW*L YHC102AW*L YHC120AW*L 460/60/3 460/60/3 460/60/3 460/60/3 575/60/3 575/60/3 575/60/3 575/60/3 72,000 90,000 102,000
116,000
72,000 90,000 102,000
116,000
10th Digit = Medium Heat, Standard Heat Exchanger YHC072A3*M 208-230/60/3 72,000 97,200 YHC092A3*M 208-230/60/3 90,000 121,500 YHC102A3*M 208-230/60/3 102,000 121,500 YHC120A3*M 208-230/60/3 116,000 162,000 YHC072A4*M YHC092A4*M YHC102A4*M YHC120A4*M YHC072AW*M YHC092AW*M YHC102AW*M YHC120AW*M 460/60/3 460/60/3 460/60/3 460/60/3 575/60/3 575/60/3 575/60/3 575/60/3 72,000 90,000 102,000 97,200 121,500 121,500 162,000 97,200 121,500 121,500 162,000
11.4 11.4 11.4 11.3 11.4 11.4 11.4 11.3 11.4 11.4 11.4 11.3
41 46 46 46 41 46 46 46 41 46 46 46
53 53 53 53 53 53 53 53 53 53 53 53
89 89 89 89 89 89 89 89 89 89 89 89
LH LH LH LH LH LH LH LH LH LH LH LH
859 909 1044 1147 859 909 1044 1147 859 909 1044 1147
116,000
72,000 90,000 102,000
116,000
10th Digit = High Heat, Standard Heat Exchanger YHC072A3*H 208-230/60/3 72,000 YHC092A3*H 208-230/60/3 90,000 YHC102A3*H 208-230/60/3 102,000 YHC120A3*H 208-230/60/3 116,000 YHC072A4*H YHC092A4*H YHC102A4*H YHC120A4*H YHC072AW*H YHC092AW*H YHC102AW*H YHC120AW*H 460/60/3 460/60/3 460/60/3 460/60/3 575/60/3 575/60/3 575/60/3 575/60/3 72,000 90,000 102,000
121,500 162,000 162,000 202,500 121,500 162,000 162,000 202,500 121,500 162,000 162,000 202,500
11.4 11.4 11.4 11.3 11.4 11.4 11.4 11.3 11.4 11.4 11.4 11.3
41 46 46 46 41 46 46 46 41 46 46 46
53 53 53 53 53 53 53 53 53 53 53 53
89 89 89 89 89 89 89 89 89 89 89 89
LH LH LH LH LH LH LH LH LH LH LH LH
859 909 1044 1147 859 909 1044 1147 859 909 1044 1147
116,000
72,000 90,000 102,000
116,000
PG 16
Table 4 Gas Heat Option, Stainless Steel Heat Exchanger (Digit 10)
Tons 3 4 5 6 7.5 8.5 10 Low (X) Medium (Y) High (Z)
1 Not available with electromechanical unit controls. 2 Economizer with Barometric Relief is for downflow configured units only. Order Economizer without Barometric Relief for horizontal configuration. Barometric relief for horizontal configured units must be ordered as field installed accessory BAYBARM010A. 3 The Manual Outside Air Damper will ship factory supplied within the unit, but must be field installed.
PG 17
1 Available for 3 phase models only. 2 3-5 ton standard motor is direct drive. 6-10 ton ton standard motor is belt drive. 3 3-5 ton oversized motor is direct drive. 6-10 ton ton oversized motor is belt drive.
Table 7 Hinged Service Access & Filters (Digit 16)
Tons 3 4 5 6 7.5 8.5 10 Standard Panels & Filters (0) $ Included $ Included $ Included $ Included $ Included $ Included $ Included Hinged Access Panels & Standard Filters (A)
Standard2 Motor (0) $ Included $ Included $ Included $ Included $ Included $ Included $ Included
PG 18
1 Through the Base Gas Opening is standard. This option adds gas piping and shutoff (field assembly required).
Table 10 Disconnect/Circuit Breaker/Phase Monitor1234 (Digit 19)
Tons 3 4 5 6 7.5 8.5 10 Unit Mounted Unit Mounted Non-Fused Circuit Disconnect Switch (1) Breaker (2) Phase Monitor (3) Phase Monitor & Phase Monitor & Non-Fused Circuit Disconnect Switch (4) Breaker (5)
1 Disconnect/Circuit Breaker/Phase Monitor is available for 3 phase models only. 2 Must order Through the Base option when ordering disconnect or Breaker. 3 Phase Monitor is available with ReliaTel models only. 4 Phase monitor will be standard on Y_C060A3,4,W (three phase).
Table 11 Convenience Outlet (Digit 20)
Tons 3 4 5 6 7.5 8.5 10 Unpowered Convenience Outlet (A) Powered 12 Convenience Outlet (B)
1 Powered Convenience Outlet Option is available for 3 phase models only. 2 Requires use of Disconnect or Circuit Breaker.
Table 12 Communications Options (Digit 21) 1
Tons 3 4 5 6 7.5 8.5 10 Comm-3/4 Trane Communications Interface (1) LonTalk Communications Interface (2) Novar 2024 Controls (3) Novar 3051 Controls (4)
N/A
1 2 3 4 5 6
Standard Refrigeration Metering Device - Short Orifice. Not available on standard efficiency models, single phase units or with electromechanical controls. Crankcase heaters, TXV's, Frostat, high and low pressure switches, face-split evaporator coil and 2" pleated filters standard with this option. Belt drive standard. Do not select Digit 15=2 (Optional Drive Motor). Not available on heat pumps. Requires selection of 2" Pleated Filters (Option B or C) under Digit 16.
2 Frostat cannot be field installed in electromechanical units. 3 High Pressure Control is standard on 3 phase units with scroll compressors and on YSC036A. 4 Crankcase heater is standard in YSC036A and YSC090A. 5 High Pressure Control is standard on all three-phase models.
PG 20
1 Not available with Electromechanical Controls. 2 Cannot be used with BAYFRST001A High Temperature Stat accessory. 3 The return air smoke detector may not fit up or work properly on the Precedent units when used in conjunction with 3rd party accessories (such as bolt on heat wheels, economizers, and power exhaust). Do not order the return air smoke detectors when using this type of accessory. 4 Return Air Smoke Detector cannot be ordered with Novar Controls.
Table 16 Monitoring Controls (Digit 25) 1
Tons 3 4 5 6 7.5 8.5 10 Clogged Filter Switch2 (1) Fan Failure Switch2 (2) Discharge Air Sensing Tube2 (3) Clogged Filter Switch and Fan Fail Switch2 (4)
Fan Fail Switch Clogged Filter and and Discharge Air Fan Fail Switches Sensing Tube24 (6) and Discharge Air Sensing Tube24 (7)
1 Not available with Electromechanical Controls. 2 These options are standard when ordering Novar Controls. 3 This option for use when ordering Novar Control only. 4 Combination of Discharge Air Sensing option, Economizer option and Tracer Summit or Tracker, Version 10 requires use of Tracer LCI-R Communications Interface. For
jobs requiring true discharge air sensing with Tracer/Tracker COMM-3 or COMM-4, contact Clarksville Light Commercial Marketing Support.
PG 21
BAYGARD040B BAYGARD041B BAYHSMT073A BAYHSMT074A BAYHSMT075A BAYHSMT076A BAYHSMT077A BAYHSMT078A BAYHSMT079A BAYHSMT080A BAYHSMT081A BAYHSMT082A BAYHSMT083A BAYHSMT084B BAYHSMT085B BAYHSMT086A BAYHSMT087A BAYHSMT088A BAYHSMT089A BAYHSDR012A
Tool-less Coil Hail Guard Tool-less Coil Hail Guard .45HP Oversized motor kit .45HP Oversized motor kit .45HP Oversized motor kit .75HP Oversized motor kit .75HP Oversized motor kit .75HP Oversized motor kit 1.2HP Oversized motor kit 1.2HP Oversized motor kit 1.2HP Oversized motor kit 2HP Belt Drive Oversized Motor 2HP Belt Drive Oversized Motor 3HP Belt Drive Oversized Motor 3HP Belt Drive Oversized Motor 3HP Belt Drive Oversized Motor 3HP Belt Drive Oversized Motor 5HP Belt Drive Oversized Motor 5HP Belt Drive Oversized Motor High Static Drive Kit
LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH
20 20 25 25 25 30 30 30 45 45 45 25 25 25 30 30 30 45 45 2
1 Lynn Haven Manufacturing has a No-Return policy for this roof curb. 2 For use with ReliaTel controlled units only. 3 BAYQACB009A adapts Voyager BAYCURB021B to accept Precedent 3 -5 ton unit. BAYQACB010A adapts Voyager BAYCURB022B to accept Precedent 3-5 ton unit.
TM
BAYQACB011A adapts Voyager BAYCURB022B to accept Precedent 6-10 ton unit. BAYQACB012A adapts Voyager BAYCURB025B to accept Precedent 6-10 ton unit. BAYQACB013A adapts Voyager BAYCURB026B to accept Precedent 6-10 ton unit. Electromechanical controlled units only.
PG 22
Model Number
Description
ReliaTel Options Module Barometric Relief Barometric Relief Power Exhaust Power Exhaust Power Exhaust CO2 Sensor Kit, Wall Mounted CO2 Sensor Kit, Duct Mounted Crankcase Heater Crankcase Heater Crankcase Heater Crankcase Heater Crankcase Heater Quick Start Kit Quick Start Kit Remote Potentiometer Selective Resistance Service Tester Temperature Sensor High Temperature Stat LP Conversion Kit LP Conversion Kit Reference Enthalpy Kit Comparative Enthalpy Kit Enthalpy Control (Solid State) Clogged Filter Switch Fan Failure Switch Discharge Air Sensing Kit Discharge Air Sensing Kit Comm-3/4 Trane Communications Interface LonTalk Communications Interface Anti-Short-Cycle Timer Evaporator Defrost Control (Frostat) High Altitude Kit Ventilation Override Kit
See Note7 LH Y*C036-060A LH Y*C072-120A LH Y*C072-120A3 LH Y*C072-120A4 LH Y*C072-120AW LH Y*C036-120A*R LH W/Econ. or Motorized OA Damper Y*C036-120A*R LH W/Econ. or Motorized OA Damper YHC036-072A3 LH YSC048-072A3 Y*C092-120A3 YHC036-072A4,AW LH YSC048-072A4,AW Y*C092-120A4,AW Y*C090A3 LH Y*C090A4 LH Y*C090AW LH YHC036-060A LH YSC048-060A YSC036A LH BAYECON085A,087A CK/001 Y*C036-120A_R LH Y*C036-120A_R Y*C036-120A_R Y*C036-060A;Y*C072**L,M Y*C090,092,102**L Y*C072A**H; Y*C090,092,102A**M,H Y*C120A**L,M,H BAYECON085A,087A BAYECON085A,087A BAYECON086A,088A Y*C036-120A_R Y*C036-120A_R Y*C036-060A_R Y*C072-120A_R Y*C036-120A_R Y*C036-120A_R Y*C036-120A_E Y*C036-120A_R Y*C036-120A Y*C036-120A*R W/ReliaTel Options Module LH CK/001 LH LH LH LH CK/001 LH LH LH LH LH LH FS/200 LH LH LH
Used With
1 Kits contain all necessary parts to achieve desired level of enthalpy control. 2 For use with ReliaTel microprocessor controlled 3 4 5 6
units only. Must be factory installed for Electromechanical controlled units. Used for true discharge air sensing in both heating and cooling. Required for supply air tempering. For use with ReliaTel controlled units only. Cannot be used in conjunction with factory installed Smoke Detector option. Installs in ductwork for horizontal configuration. For downflow configuration, it installs in the unit's horizontal return duct. See Installer's Guide for more information.
8 9
installed accessories Clogged Filter Switch (BAYDFPS003A), Fan Fail Switch (BAYDFPS004A), Discharge Air Sensing Kit (BAYTUBE004A or BAYTUBE005A) or Evaporator Defrost Control (Frostat) (BAYLOAM020B) unless the following options are factory installed: Frostat, Smoke Detector, Clogged Filter Switch, Fan Failure Switch, Discharge Air Sensing Kit. These factory installed options include the ReliaTel Options Module. Electromechanical controlled units only. Interface allows 3-10 ton units with ReliaTel Controls to communicates with Tracer 100, Tracker, VariTrac II, and is the preferred method of communication to Tracer Summit.
0 Power Exhaust cannot be used with Barometric Relief. Order Economizer without Barometric Relief. q Quantity 2 required for Y*C092-120A. w For use with ReliaTel controlled units only. e Interface allows a unit with ReliaTel Controls to
communicate as a Trane LonTalk device or directly with generic LonTalk Network BAS Controls.
PG 23
Used with Y*C036-120A_R Y*C036-120A_R Y*C036-120A_R Y*C036-120A_R Y*C036-120A_R Y*C036-120A_R BAYSENS006B, 008B, 010B, & 019C Y*C036-120A_R Y*C036-120A_R YHC036_120A_R YHC036_120A_R BAYSENS019C
1 Used with Integrated Comfort Systems, any unit type. These sensors do not work with TCM. Consult BASD Marketing for them. 2 See Accessory IOM for operational characteristics. 3 Functional only with ReliaTel controls.
* Either standard or high efficiency models
Thermostats:
Model Number BAYSTAT040A13 BAYBASE008A BAYBASE006A BAYSENS033A BAYSENS034A TCONT200AN11AA BAY28X1902 BAYSTAT050A BAYSTAT051A BAYSTAT052A BAYSTAT053A Mfg. Shipping Description Used with Plant Weight Programmable Thermostat Y*C036-120A CK/001 1 Subbase 1-Stage Htg./Clg. BAYSTAT040A CK/001 1 Subbase 2-Stage Htg./Clg. BAYSTAT040A CK/001 1 Remote Wall Sensor BAYSTAT040A CK/001 1 Remote Duct Sensor BAYSTAT040A CK/001 1 Electronic, 1Htg/1Clg (Non Prog.) All Cooling/(Gas or Elec) TY 1 Locking Thermostat Cover for up to 4 units Room Thermostats TY 1 2Htg/2Clg Digital Display Y*C036-120A_R CK/001 1 Programmable Thermostat 1Htg/1Clg Digital Display Thermostat Y*C036-060A_R CK/001 1 2Htg/2Clg Digital Display Programmable Y*C036-120A_R CK/001 1 "TOUCHSCREEN" Thermostat 3Htg/2Clg Digital Display Programmable Y*C036-120A_R CK/001 1 Thermostat with Relative Humidity (with Dehumidification Option) Sensing Built-In 3Htg/2Clg Digital Display Thermostat Y*C036-120A_R CK/001 1 Return Air Remote Sensor BAYSTAT050A,051A, CK/001 1 052A,053A Wall Mounted Remote Sensor BAYSTAT050A,051A, CK/001 1 052A,053A
1 2 3
*
Requires use of subbase BAYBASE006A or BAYBASE008A. Do not use with Programmable Thermostats. Thermostat does not include fan or system switches. Either standard or high efficiency models.
PG 24
Model Nomenclature
Y 1
H 2
C 033 A 3 4,5,6 7
3 8
R L A ** C 0 0 0 C 1 9 10 11 12,13 14 15 16 17 18 19
DIGIT 15 - Supply Fan/Drive Type/Motor 0 = Standard Belt Drive DIGIT 16 - Hinged Service Access & Filters 0 = Standard Panels & Filters A = Hinged Access Panels & Standard Filters B = Standard Panels & 2" Pleated Filters C = Hinged Access Panels & 2" Pleated Filters DIGIT 17 - Condenser Coil Protection 0 = Standard Coil 1 = Standard Coil with Hail Guard 2 = Epoxy Coated Condenser Coil 3 = Epoxy Coated Condenser Coil with Hail Guard 4 = CompleteCoat Condenser Coil 5 = CompleteCoat Condenser Coil with Hail Guard DIGIT 18 - Through the Base Provisions 0 = No Through the Base Provisions A = Through the Base Electric B = Through the Base Gas Piping C = Through the Base Electric and Gas Piping DIGIT 19 - Disconnect/Circuit Breaker Phase Monitor (3 phase only) 0 = No Disconnect, Circuit Breaker or Phase Monitor 1 = Unit Mounted Non-Fused Disconnect 2 = Unit Mounted Circuit Breaker 3 = Phase Monitor 4 = Phase Monitor and Non-Fused Disconnect Switch 5 = Phase Monitor and Circuit Breaker DIGIT 20 - Convenience Outlet 0 = No Convenience Outlet A = Unpowered Convenience Outlet B = Powered Convenience Outlet (3 phase only) DIGIT 21 - Communications Options 0 = No Communications Interface 1 = Trane Communications Interface 2 = LonTalk Communications Interface
DIGIT 1 - Unit Function Y = DX Cooling, Gas Heat DIGIT 2 - Efficiency H = High Efficiency DIGIT 3 - Airflow C = Convertible DIGITS 4,5,6 - Nominal Gross Cooling Capacity (MBh) 033 = 3 Ton 043 = 4 Ton 063 = 5 Ton DIGIT 7 - Major Design Sequence A = R-22 Refrigerant DIGIT 8 - Unit Voltage 3 = 208-230/60/3 4 = 460/60/3 W = 575/60/3 DIGIT 9 - Unit Controls E = Electro-Mechanical R = ReliaTelMicro-processor DIGIT 10 - Heating Capacity L = Low M = Medium H = High X = Low, Stainless Steel Heat Exchanger Y = Medium, Stainless Steel Heat Exchanger Z = High, Stainless Steel Heat Exchanger DIGIT 11 - Minor Design Sequence A = First Sequence DIGIT 12,13 - Service Sequence ** = Factory Assigned DIGIT 14 - Fresh Air Selection 0 = No Fresh Air A = Manual Outside Air Damper 0-50% B = Motorized Outside Air Damper 0-50% C = Economizer, Dry Bulb 0-100% without Barometric Relief D = Economizer, Dry Bulb 0-100% with Barometric Relief E = Economizer, Reference Enthalpy 0-100% without Barometric Relief F = Economizer, Reference Enthalpy 0-100% with Barometric Relief G = Economizer, Comparative Enthalpy 0-100% without Barometric Relief H = Economizer, Comparative Enthalpy 0-100% with Barometric Relief
3 = Novar 2024 Controls 4 = Novar 3051 Controls DIGIT 22 - Refrigeration System Option 0 = Standard Refrigeration Coil B = Dehumidification (Hot Gas Reheat Coil) DIGIT 23 - Refrigeration Controls 0 = No Refrigeration Control 1 = High Pressure Control 2 = Frostat 3 = Crankcase Heater 4 = High Pressure Control and Frostat 5 = High Pressure Control and Crankcase Heater 6 = Frostat and Crankcase Heater 7 = High Pressure Control, Frostat and Crankcase Heater DIGIT 24 - Smoke Detector 0 = No Smoke Detector A = Return Air Smoke Detector B = Supply Air Smoke Detector C = Supply and Return Air Smoke Detectors DIGIT 25 - Monitoring Controls 0 = No Monitoring Control 1 = Clogged Filter Switch 2 = Fan Failure Switch 3 = Discharge Air Sensing Tube 4 = Clogged Filter Switch and Fan Fail Switch 5 = Clogged Filter Switch and Discharge Air Sensing Tube 6 = Fan Fail Switch and Discharge Air Sensing Tube 7 = Clogged Filter and Fan Fail Switches and Discharge Air Sensing Tube 8 = Novar Return Air Sensor
Example: Model number YHC033A3RLA**C000C10001A10 describes a unit with the following characteristics: DX Cooling with natural gas heating, 3 ton nominal cooling capacity, 208-230/60/3 power supply, ReliaTel controls, low heat model. 0-100% dry bulb economizer without barometric relief, standard belt drive motor, standard access panels, standard condenser coil with no coil protection, through the base electric and gas access, non-fused disconnect, no convenience outlet or communications interface, standard refrigeration coil, high pressure control, return air smoke detector, and clogged filter switch.
PG 25
3 5 Ton YHC033-063A
Table 1 Main Assembly 13 SEER High Efficiency (Digits 1-8 & Digit 10)
Gross Capacity Capacity Heating Model Power Cooling Output Number Supply (BTUH) (BTUH) SEER 10th Digit = Low Heat, Standard Heat Exchanger YHC033A3*L 208-230/60/3 38,000 48,000 13.0 YHC043A3*L 208-230/60/3 49,800 48,000 13.0 YHC063A3*L 208-230/60/3 62,400 48,000 13.0 YHC033A4*L YHC043A4*L YHC063A4*L YHC033AW*L YHC043AW*L YHC063AW*L 460/60/3 460/60/3 460/60/3 575/60/3 575/60/3 575/60/3 38,000 49,800 62,400 38,000 49,800 62,400 48,000 48,000 48,000 48,000 48,000 48,000 13.0 13.0 13.0 13.0 13.0 13.0 Mfg. Plant LH LH LH LH LH LH LH LH LH Shipping Weight 620 662 697 620 662 697 620 662 697
10th Digit = Medium Heat, Standard Heat Exchanger YHC033A3*M 208-230/60/3 38,000 64,000 YHC043A3*M 208-230/60/3 49,800 64,000 YHC063A3*M 208-230/60/3 62,400 64,000 YHC033A4*M YHC043A4*M YHC063A4*M YHC033AW*M YHC043AW*M YHC063AW*M 460/60/3 460/60/3 460/60/3 575/60/3 575/60/3 575/60/3 38,000 49,800 62,400 38,000 49,800 62,400 64,000 64,000 64,000 64,000 64,000 64,000
32 32 36 32 32 36 36 36 36
43 43 43 43 43 43 43 43 43
69 69 69 69 69 69 69 69 69
LH LH LH LH LH LH LH LH LH
10th Digit = High Heat, Standard Heat Exchanger YHC033A3*H 208-230/60/3 38,000 96,000 YHC043A3*H 208-230/60/3 49,800 96,000 YHC063A3*H 208-230/60/3 62,400 104,000 YHC033A4*H YHC043A4*H YHC063A4*H YHC033AW*H YHC043AW*H YHC063AW*H 460/60/3 460/60/3 460/60/3 575/60/3 575/60/3 575/60/3 38,000 49,800 62,400 38,000 49,800 62,400 96,000 96,000 104,000 96,000 96,000 104,000
32 32 36 32 32 36 36 36 36
43 43 43 43 43 43 43 43 43
69 69 69 69 69 69 69 69 69
LH LH LH LH LH LH LH LH LH
PG 26
3 5 Ton YHC033-063A
Table 2 Unit Controls (Digit 9)
Tons 3 4 5 Electromechanical (E) $ Included $ Included $ Included ReliaTel (R)
Table 3 Gas Heat Option, Stainless Steel Heat Exchanger (Digit 10)
Tons 3 4 5 6 7.5 8.5 10 Low (X) Medium (Y) High (Z)
Tons 3 4 5
Tons 3 4 5
1 Not available with electromechanical unit controls. 2 Economizer with Barometric Relief is for downflow configured units only. Order Economizer without Barometric Relief for horizontal configuration. relief for horizontal configured units must be ordered as field installed accessory BAYBARM010A. 3 The Manual Outside Air Damper will ship factory supplied within the unit, but must be field installed.
Table 5 Supply Fan Drive Type/Motor (Digit 15)
Tons 3 4 5 Standard1 Motor (0) Belt Drive Belt Drive Belt Drive
Barometric
PG 27
3 5 Ton YHC033-063A
Table 7 Condenser Coil Protection (Digit 17)
Tons 3 4 5 Standard Coil (0) $ Included $ Included $ Included Standard Coil with Hail Guard(1) Epoxy Coated Condenser Coil (2)
1 Through the Base Gas Opening is standard. This option adds gas piping and shutoff (field assembly required).
Table 9 Disconnect/Circuit Breaker/Phase Monitor123 (Digit 19)
Tons 3 4 5 Unit Mounted Unit Mounted Non-Fused Circuit Disconnect Switch (1) Breaker (2) Phase Monitor (3) Phase Monitor & Phase Monitor & Non-Fused Circuit Disconnect Switch (4) Breaker (5)
1 Disconnect/Circuit Breaker/Phase Monitor is available for 3 phase models only. 2 Must order Through the Base option when ordering disconnect or Breaker. 3 Phase Monitor is available with ReliaTel models only.
Table 10 Convenience Outlet (Digit 20)
Tons 3 4 5 Unpowered Convenience Outlet (A) Powered 12 Convenience Outlet (B)
1 Powered Convenience Outlet Option is available for 3 phase models only. 2 Requires use of Disconnect or Circuit Breaker.
Table 11 Communications Options (Digit 21) 1
Tons 3 4 5 Comm-3/4 Trane Communications Interface (1) LonTalk Communications Interface (2) Novar 2024 Controls (3) Novar 3051 Controls (4)
PG 28
3 5 Ton YHC033-063A
Table 12 Refrigeration System Control (Digit 22)
Tons 3 4 5 Standard1 Refrigeration System Control (0) $ Included $ Included $ Included Dehumidification (Hot Gas Reheat Coil) 23456 (B)
1 2 3 4 5 6
Standard Refrigeration Metering Device - TXV. Not available on standard efficiency models, single phase units or with electromechanical controls. Crankcase heaters, TXV's, Frostat, high and low pressure switches, face-split evaporator coil and 2" pleated filters standard with this option. Belt drive standard. Do not select Digit 15=2 (Optional Drive Motor). Not available on heat pumps. Requires selection of 2" Pleated Filters (Option B or C) under Digit 16.
1 Not available with Electromechanical Controls. 2 Frostat cannot be field installed in electromechanical units. 3 High Pressure Control is standard on 3 phase units with scroll compressors. 4 High Pressure Control is standard on all three-phase models.
Table 14 Smoke Detector (Digit 24) 123
Tons 3 4 5 Return Air Smoke Detector4 (A) Supply Air Smoke Detector (B) Supply and Return Air Smoke Detector4 (C)
1 2 3 4
Not available with Electromechanical Controls. Cannot be used with BAYFRST001A High Temperature Stat accessory. The return air smoke detector may not fit up or work properly on the Precedent units when used in conjunction with 3rd party accessories (such as bolt on heat wheels, economizers, and power exhaust). Do not order the return air smoke detectors when using this type of accessory. Return Air Smoke Detector cannot be ordered with Novar Controls.
PG 29
3 5 Ton YHC033-063A
Table 15 Monitoring Controls (Digit 25) 1
Tons 3 4 5 Clogged Filter Switch2 (1) Fan Failure Switch2 (2)
Fan Fail Switch Clogged Filter and and Discharge Air Fan Fail Switches Sensing Tube24 (6) and Discharge Air Sensing Tube24 (7)
1 Not available with Electromechanical Controls. 2 These options are standard when ordering Novar Controls. 3 This option for use when ordering Novar Control only. 4 Combination of Discharge Air Sensing option, Economizer option and Tracer Summit or Tracker, Version 10 requires use of Tracer LCI-R Communications Interface. For
jobs requiring true discharge air sensing with Tracer/Tracker COMM-3 or COMM-4, contact Clarksville Light Commercial Marketing Support.
PG 30
3 5 Ton YHC033-063A
Accessories:
Model Number BAYCURB042A1 BAYQACB009A1 BAYQACB010A1 BAYECON085A2 BAYECON086A3 BAYDMPR051A2 BAYDMPR052A3 BAYDMPR053B BAYGARD036B BAYGARD037B
BAYABRD001C BAYBARM010A BAYCO2K001B BAYCO2K003B BAYCCHT010B BAYCCHT011B BAYSTAT023 BAYSERV001A BAYSENS016A BAYFRST001A BAYLPKT028B BAYENTH005A BAYENTH006B BAYENTH001A BAYDFPS003B BAYDFPS004A BAYTUBE005A BAYICSI003A
Description Roof Curb Quick Adapt Roof Curb Quick Adapt Roof Curb 0-100% Dry BulbEconomizer without Barometric Relief 0-100% Dry Bulb Economizer without Barometric Relief 0-50% Motorized Outside Air Damper 0-50% Motorized Outside Air Damper 0-50% Manual Outside Air Damper Tool-less Condenser Coil Hail Guard Tool-less Condenser Coil Hail Guard
ReliaTel Options Module Barometric Relief CO2 Sensor Kit, Wall Mounted CO2 Sensor Kit, Duct Mounted Crankcase Heater Crankcase Heater Remote Potentiometer Selective Resistance Service Tester Temperature Sensor High Temperature Stat LP Conversion Kit Reference Enthalpy Kit Comparative Enthalpy Kit Enthalpy Control (Solid State) Clogged Filter Switch Fan Failure Switch Discharge Air Sensing Kit Comm-3/4 Trane Communications Interface Comm-3/4 LonTalk Communications Interface Anti-Short-Cycle Timer Evaporator Defrost Control (Frostat) Low Static Drive Kit Low Static Drive Kit Low Static Drive Kit Ventilation Override Kit
Used With YHC033-063A YHC033-063A YHC033-063A YHC033-063A_R YHC033-063A_E YHC033-063A_R YHC033-063A_E YHC033-063A YHC033, 043A YHC063A
See Note YHC033-063A YHC033-063A_R W/Econ. YHC033-063A_R W/Econ. YHC033-063A, A3 YHC033-063A4,AW BAYECON085A,087A YHC033-063A_R YHC033-063A_R YHC033-063A_R YHC033-063A BAYECON085A,087A BAYECON085A,087A BAYECON0086A,088A YHC033-063A_R YHC033-063A_R YHC033-063A_R YHC033-063A_R YHC033-063A_R
Lynn Haven Manufacturing has a No-Return policy for this roof curb. For use with ReliaTelTM controlled units only For use with electromechanical controlled units only. Kits contain all necessary parts to achieve desired level of enthalpy control. For ReliaTelTM microprocessor controlled units only. Must be factory installed for electromechanical controlled units Used for true discharge air sensing in both heating and cooling.Required for supply air tempering. Barometric Relief accessory installs in ductwork for horizontal configuration. For downflow configuration, installs in the unit's horizontal return duct. See Installer's Guide for complete instructions.
YHC033-063A_E CK/001 YHC033-063A_R LH YHC033A, 3, 4, WR LH YHC043A, 3, 4, WR LH YHC063A, 3, 4, WR LH YHC033-063A*R LH W/ReliaTel Options Module
BAYABRD001C is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS003A), Fan Fail Switch (BAYDFPS004A), Discharge Air Sensing Kit (BAYTUBE004A) or Evaporator Defrost Control (Frostat) (BAYLOAM020B) unless the following options are factory installed: Frostat, Smoke Detector, Clogged Filter Switch, Fan Failure Switch, Discharge Air Sensing Kit. These factory installed options include the ReliaTelTM Options Module. Interface allows a unit with ReliaTelTM Controls to communicates with Tracer 100, Tracker, VariTrac II, and is the preferred method of communication to Tracer Summit.
Interface allows a unit with ReliaTelTM Controls to communicate as a Trane LonTalk device or directly with generic LonTalk Network BAS Controls. Available for Cooling Units only
PG 31
3 5 Ton YHC033-063A
Zone Sensors for ReliaTel Controlled Units:
Model Number BAYSENS006B BAYSENS008B BAYSENS010B BAYSENS019C3 BAYSENS013C1 BAYSENS014C1 BAYSENS017B BAYSENS032A3 BAYSENS035A3 BAYSENS036A BAYSENS037A BAYMTPL003B BAYMTPL004B Description Single Setpoint Manual Changeover Dual Setpoint Manual or Auto Changeover Dual Setpoint Man. or Auto Changeover with System Function Lights Programmable Night Setback w/System Function Lights Room Sensor w/ Override and Cancel Buttons Room Sensor w/ Temp. Adjustment with Override and Cancel Buttons Remote Room Sensor Used with YHC033-063A_R YHC033-063A_R YHC033-063A_R YHC033-063A_R YHC033-063A_R YHC033-063A_R
1 Used with Integrated ComforT Systems, any unit type. These sensors do not work with TCM. Consult BASD Marketing for them. 2 See Accessory IOM for operational characteristics. 3 Functional only with ReliaTel controls.
* Either standard or high efficiency models
BAYSENS006B,008B, 010B, & 019C Dual Thermistor Remote Zone Sensor YHC033-063A_R Digital Display Zone Sensor YHC033-063A_R Wall-Mounted Humidity Zone Sensor YHC033-063A_R Duct-Mounted Humidity Zone Sensor YHC033-063A_R Retrofit Wall Cover Plate Kit BAYSENS019C 7.25" x 6.0" Retrofit Wall Cover Plate Kit BAYSENS006,008 4.75" x 4.75" 010B,013,014C,017B
Thermostats:
Model Number BAYSTAT040A24 BAYBASE008A BAYBASE006A BAYSENS033A BAYSENS034A TCONT200AN11AA BAY28X1903 BAY24X042 BAYSTAT050A BAYSTAT051A BAYSTAT052A BAYSTAT053A Description Programmable Thermostat Subbase 1-Stage Htg./Clg. Subbase 2-Stage Htg./Clg. Remote Wall Sensor Remote Duct Sensor Electronic, 1Htg/1Clg (Non Prog.) Locking Thermostat Cover for up to 4 units DPDT Fan and Electric Heat Relay 2Htg/2Clg Digital Display Programmable Thermostat 1Htg/1Clg Digital Display Thermostat 2Htg/2Clg Digital Display Programmable "TOUCHSCREEN" Thermostat 3Htg/2Clg Digital Display Programmable Thermostat with Relative Humidity Sensing Built-In 3Htg/2Clg Digital Display Thermostat Return Air Remote Sensor Wall Mounted Remote Sensor Used with YHC033-063A BAYSTAT040A BAYSTAT040A BAYSTAT040A BAYSTAT040A All Cooling/(Gas or Elec) Room Thermostats BAYSTAT051,052 YHC033-063A_R YHC033-063A_R YHC033-063A_R Mfg. Shipping Plant Weight CK/001 1 CK/001 1 CK/001 1 CK/001 1 CK/001 1 TY 1 TY 1 TY 1 CK/001 1 CK/001 CK/001 1 1 1
YHC033-063A_R CK/001 (with Dehumidification Option) YHC033-063A_R BAYSTAT050A,051A, 052A,053A BAYSTAT050A,051A 052A,053A CK/001 CK/001 CK/001
1 1 1
1 Requires DPDT Fan and Electric Heat Relay BAY24x042 when using electric heat. 2 Requires use of subbase BAYBASE006A or BAYBASE008A. 3 Do not use with programmable thermostats. 4 Thermostat does not include fan or system switches.
PG 32
Model Nomenclature
Y 1
S 2
C 036 E 3 4,5,6 7
3 8
R B A ** C 0 0 0 A 1 9 10 11 12,13 14 15 16 17 18 19
DIGIT 15 - Supply Fan/Drive Type/Motor 0 = Standard Drive7 DIGIT 16 - Hinged Service Access/Filters 0 = Standard Panels/Standard Filters A = Hinged Access Panels/Standard Filters B = Standard Panels/2 Pleated Filters C = Hinged Access Panels/2 Pleated Filters DIGIT 17 - Condenser Coil Protection 0 = Standard Coil 1 = Standard Coil with Hail Guard 2 = Epoxy Coated Condenser Coil 3 = Epoxy Coated Condenser Coil with Hail Guard
1 23
A 24
1 25
DIGIT 1 - Unit Function Y = DX Cooling DIGIT 2 - Efficiency S = Standard Efficiency (13 SEER R-410A) DIGIT 3 -Airflow C = Convertible DIGITS 4,5,6 - Nominal Gross Cooling Capacity (MBh) 036 = 3 Ton 046 = 4 Ton 060 = 5 Ton DIGIT 7 - Major Design Sequence E = R-410A Refrigerant DIGIT 8 - Unit Voltage 1 = 208-230/60/1 3 = 208-230/60/3 4 = 460/60/3 W = 575/60/3 DIGIT 9 - Unit Controls E = Electromechanical1 R = ReliaTelMicroprocessor DIGIT 10 - Heating Capacity Note: (Applicable to Digit 1, Y models only) L = Low M = Medium H = High X = Low, Stainless Steel Heat Exchanger Y = Medium, Stainless Steel Heat Exchanger Z = High, Stainless Steel Heat Exchanger DIGIT 11 - Minor Design Sequence A = First Sequence DIGITS 12, 13 - Service Sequence ** = Factory Assigned DIGIT 14 - Fresh Air Selection 0 = No Fresh Air A = Manual Outside Air Damper 0-50%5 B = Motorized Outside Air Damper 0-50% C = Economizer, Dry Bulb 0-100% without Barometric Relief9 D = Economizer, Dry Bulb 0-100% with Barometric Relief9 E = Economizer, Reference Enthalpy 0-100% without Barometric Relief49 F = Economizer, Reference Enthalpy 0-100% with Barometric Relief49 G = Economizer, Comparative Enthalpy 0-100% without Barometric Relief49 H = Economizer, Comparative Enthalpy 0-100% with Barometric Relief49
DIGIT 24 - Smoke Detector4o 0 = No Smoke Detector A = Return Air Smoke Detectorrt B = Supply Air Smoke Detector C = Supply and Return Air Smoke Detectorsrt
DIGIT 18 - Through the Base Provisions Note: (Applicable to Digit 1, Y models only) 0 = No Through the Base Provisions A = Through the Base Electric0 Note: (Applicable to Digit 1, Y models only) B = Through the Base Gas Piping C = Through the Base Electric and Gas Pipingi DIGIT 19 - Disconnect/Circuit Breaker/ Phase Monitor (3 phase only) 0 = No Disconnect/No Circuit Breaker/No Phase Monitor 1 = Unit Mounted Non-Fused Disconnect0 2 = Unit Mounted Circuit Breaker0 3 = Phase Monitor 4 = Phase Monitor & Non-Fused Disconnect Switch 5 = Phase Monitor & Circuit Breaker DIGIT 20 - Convenience Outlet 0 = No Convenience Outlet A = Unpowered Convenience Outlet B = Powered Convenience Outlet (3 phase only)q DIGIT 21 - Communications Options4 0 = No Communications Interface 1 = Trane Communications Interface 2 = LonTalk Communications Interface 3 = Novar 2024 Controls1 4 = Novar 3051 Controls1 DIGIT 22 - Refrigeration System Option 0 = Standard Refrigeration Coilw B = Dehumidification (Hot Gas Reheat Coil)138 DIGIT 23 - Refrigeration Controls 0 = No Refrigeration Control6 1 = Frostate 2 = Crankcase Heater2
DIGIT 25 - Monitoring Controls4 0 = No Monitoring Controly 1 = Clogged Filter Switchy 2 = Fan Failure Switchy 3 = Discharge Air Sensing Tubey 4 = Clogged Filter Switch and Fan Fail Switchy 5 = Clogged Filter Switch and Discharge Air Sensing Tubey 6 = Fan Fail Switch and Discharge Air Sensing Tubey 7 = Clogged Filter and Fan Fail Switches and Discharge Air Sensing Tubey 8 = Novar Return Air Sensoru
Explanation of Model Number Notes 119 follow. Unless otherwise noted, feature available for all Y models, tonnages and phases.
1 Not available for 3-5 ton, R-410A Heat Pumps. 2 Standard on 4 ton , 3 phase Heat Pumps and 5 ton Heat Pumps. 3 Available for R-22 units only. 4 Not available with electromechanical controls. 5 Manual outside air damper will ship factory supplied within the unit, but must be field installed. 6 High pressure control is standard on all units. 7 Multispeed direct drive standard on 1 phase. Belt drive standard on 3 phase. 8 Requires selection of 2 pleated filters 9 Economizer with Barometric Relief is for downflow 0 q w e r t y u i o
configured units only. Order Economizer without Barometric Relief for horizontal configuration. Barometric Relief for horizontal configured units must be ordered as field installed accessory. Through the base electric required when ordering disconnect/circuit breaker options. Requires use of Disconnect or Circuit Breaker. Standard metering devices are TXVs. Frostat cannot be field installed in electro-mechanical units. The return air smoke detector may not fit up or work properly on the Precedent units when used in conjunction with 3rd party accessories such as bolt on heat wheels, economizers and power exhaust. Do not order the return air smoke detectors when using this type of accessory. Return air smoke detector cannot be ordered with Novar Controls. These options are standard when ordering Novar Controls. This option is used when ordering Novar Controls. Includes gas piping and shutoff (field assembly required). Not available with high temperature stat accessory.
Example: Model number YSC036E3RBA**C000A10001A1 describes a unit with the following characteristics: DX Cooling, 3 ton nominal cooling capacity, 208-230/60/3 power supply, ReliaTel controls, 6 kW electric heater model. 0-100% dry bulb economizer without barometric relief, standard belt drive motor, standard access panels/filters, standard condenser coil with no coil protection, through the base electric, non-fused disconnect, no convenience outlet or communications interface, standard refrigeration coil, high pressure control, return air smoke detector, and clogged filter switch.
PG 33
3 5 Ton YSC036-060E
Table 1 Main Assembly 3-5 Ton Standard Efficiency (Digits 1-8 & Digit 10)
Gross Capacity Capacity Heating Model Power Cooling Output Number Supply (BTUH) (BTUH) SEER 10th Digit = Low Heat, Standard Heat Exchanger YSC036E3*L 208-230/60/3 37,150 48,000 13.0 YSC048E3*L 208-230/60/3 49,450 48,000 13.0 YSC060E3*L 208-230/60/3 62,270 48,000 13.0 YSC036E4*L YSC048E4*L YSC060E4*L YSC036EW*L YSC048EW*L YSC060EW*L 460/60/3 460/60/3 460/60/3 575/60/3 575/60/3 575/60/3 37,150 49,450 62,270 37,150 49,450 62,270 48,000 48,000 48,000 48,000 48,000 48,000 13.0 13.0 13.0 13.0 13.0 13.0 Mfg. Plant LH LH LH LH LH LH LH LH LH Shipping Weight 607 638 688 607 638 688 607 638 688
10th Digit = Medium Heat, Standard Heat Exchanger YSC036E3*M 208-230/60/3 37,150 64,000 YSC048E3*M 208-230/60/3 49,450 64,000 YSC060E3*M 208-230/60/3 62,270 64,000 YSC036E4*M YSC048E4*M YSC060E4*M YSC036EW*M YSC048EW*M YSC060EW*M 460/60/3 460/60/3 460/60/3 575/60/3 575/60/3 575/60/3 37,150 49,450 62,270 37,150 49,450 62,270 64,000 64,000 64,000 64,000 64,000 64,000
36 36 36 36 36 36 36 36 36
43 43 43 43 43 43 43 43 43
69 69 69 69 69 69 69 69 69
LH LH LH LH LH LH LH LH LH
10th Digit = High Heat, Standard Heat Exchanger YSC036E3*H 208-230/60/3 37,150 96,000 YSC048E3*H 208-230/60/3 49,450 96,000 YSC060E3*H 208-230/60/3 62,270 104,000 YSC036E4*H YSC048E4*H YSC060E4*H YSC036EW*H YSC048EW*H YSC060EW*H 460/60/3 460/60/3 460/60/3 575/60/3 575/60/3 575/60/3 37,150 49,450 62,270 37,150 49,450 62,270 96,000 96,000 104,000 96,000 96,000 104,000
36 36 36 36 36 36 36 36 36
43 43 43 43 43 43 43 43 43
69 69 69 69 69 69 69 69 69
LH LH LH LH LH LH LH LH LH
PG 34
3 5 Ton YSC036-060E
Table 2 Unit Controls (Digit 9)
Tons 3 4 5 Electromechanical (E) $ Included $ Included $ Included ReliaTel (R)
Table 3 Gas Heat Option, Stainless Steel Heat Exchanger (Digit 10)
Tons 3 4 5 Low (X) Medium (Y) High (Z)
Tons 3 4 5
Tons 3 4 5
1 Not available with electromechanical unit controls. 2 Economizer with Barometric Relief is for downflow configured units only. Order Economizer without Barometric Relief for horizontal configuration. Barometric relief for horizontal configured units must be ordered as field installed accessory BAYBARM010A. 3 The Manual Outside Air Damper will ship factory supplied within the unit, but must be field installed.
Table 5 Supply Fan Drive Type/Motor (Digit 15)
Tons 3 4 5 Standard1 Motor (0) $ Included $ Included $ Included
1 3-5 ton 1 phase standard motor is direct drive, 3-5 ton 3 phase standard motor is belt drive.
PG 35
3 5 Ton YSC036-060E
Table 6 Hinged Service Access & Filters (Digit 16)
Tons 3 4 5 Standard Panels & Filters (0) $ Included $ Included $ Included Hinged Access Panels & Standard Filters (A)
1 Through the Base Gas Opening is standard. This option adds gas piping and shutoff (field assembly required).
Table 9 Disconnect/Circuit Breaker/Phase Monitor123 (Digit 19)
Tons 3 4 5 Unit Mounted Unit Mounted Non-Fused Circuit Disconnect Switch (1) Breaker (2) Phase Monitor (3) Phase Monitor & Phase Monitor & Non-Fused Circuit Disconnect Switch (4) Breaker (5)
1 Disconnect/Circuit Breaker/Phase Monitor is available for 3 phase models only. 2 Must order Through the Base option when ordering disconnect or Breaker. 3 Phase Monitor is available with ReliaTel models only.
Table 10 Convenience Outlet (Digit 20)
Tons 3 4 5 Unpowered Convenience Outlet (A) Powered 12 Convenience Outlet (B)
1 Powered Convenience Outlet Option is available for 3 phase models only. 2 Requires use of Disconnect or Circuit Breaker.
PG 36
3 5 Ton YSC036-060E
1 2
Standard Refrigeration Metering Device - Thermal Expansion Valve. Available for R-22 only
PG 37
3 5 Ton YSC036-060E
Table 14 Smoke Detector (Digit 24) 123
Tons 3 4 5 Return Air Smoke Detector4 (A) Supply Air Smoke Detector (B)
1 2 3 4
Not available with Electromechanical Controls. Cannot be used with BAYFRST001A High Temperature Stat accessory. The return air smoke detector may not fit up or work properly on the Precedent units when used in conjunction with 3rd party accessories (such as bolt on heat wheels, economizers, and power exhaust). Do not order the return air smoke detectors when using this type of accessory. Return Air Smoke Detector cannot be ordered with Novar Controls.
Fan Fail Switch Clogged Filter and and Discharge Air Fan Fail Switches Sensing Tube24 (6) and Discharge Air Sensing Tube24 (7)
1 Not available with Electromechanical Controls. 2 These options are standard when ordering Novar Controls. 3 This option for use when ordering Novar Control only.
4 Combination of Discharge Air Sensing option, Economizer option and Tracer Summit or Tracker, Version 10 requires use of Tracer LCI-R Communications Interface. For jobs requiring true discharge air sensing with Tracer/Tracker COMM-3 or COMM-4, contact Clarksville Light Commercial Product Support.
PG 38
3 5 Ton YSC036-060E
Accessories:
BAYCURB042A1 BAYQACB009A1 BAYQACB010A1 BAYECON085A2 BAYECON086A3 BAYDMPR051A2 BAYDMPR052A3 BAYDMPR053B BAYGARD036B BAYGARD037B BAYABRD001C7 BAYBARM010A9 BAYCO2K001B BAYCO2K003B BAYCCHT010Be BAYCCHT011Be BAYKSKT256A BAYSTAT0237 BAYSERV001A7 BAYSENS016A7 BAYFRST001A78 BAYLPKT028B BAYENTH005A4 BAYENTH006B4 BAYENTH001A BAYDFPS003B0 BAYDFPS004A70 BAYTUBE004A670 BAYICSI003A7w BAYLTCI002Brt BAYASCT001q BAYLOAM020B50 BAYHAKT010B BAYVNOR001B
Model Number
Description
Roof Curb Quick Adapt Curb3 Quick Adapt Curb3 0-100% Dry Bulb Economizer without Barometric Relief 0-100% Dry Bulb Economizer without Barometric Relief 0-50% Motorized Outside Air Damper 0-50% Motorized Outside Air Damper 0-50% Manual Outside Air Damper Tool-less Condenser Coil Hail Guard Tool-less Coil Hail Guard ReliaTel Options Module Barometric Relief CO2 Sensor Kit, Wall Mounted CO2 Sensor Kit, Duct Mounted Crankcase Heater Crankcase Heater Quick Start Kit Remote Potentiometer Selective Resistance Service Tester Temperature Sensor High Temperature Stat LP Conversion Kit Reference Enthalpy Kit Comparative Enthalpy Kit Enthalpy Control (Solid State) Clogged Filter Switch Fan Failure Switch Discharge Air Sensing Kit Comm-3/4 Trane Communications Interface LonTalk Communications Interface Anti-Short-Cycle Timer Evaporator Defrost Control (Frostat) High Altitude Kit Ventilation Override Kit
Used With
YSC036-060E YSC036-060E YSC036-60E YSC036-060E_R YSC036-060E_E YSC036-060E_R YSC036-060E_E YSC036-060E
3 3
LH LH LH LH LH LH LH LH
YSC036,048,060E**L,M LH YHC036,048E**L,M YSC036,048,060E**H LH YHC036,048E**H YHC060E**L,M,H See Note7 LH YSC036-060E LH YSC036-060E*R LH W/Econ. or Motorized OA Damper YSC036-060E*R LH W/Econ. or Motorized OA Damper YSC036-0060E3 LH YSC036-0060E4,EW LH YSC036E LH BAYECON085A CK/001 YSC036-060E_R LH YSC036-060E_R YSC036-060E_R YSC036-060E BAYECON085A BAYECON085A BAYECON086A YSC036-060E_R YSC036-060E_R YSC036-060E_R YSC036-060E_R YSC036-060E_R YSC036-060E_E YSC036-060E_R YSC036-060E YSC036-060E*R W/ReliaTel Options Module LH CK/001 LH LH LH CK/001 LH LH LH LH LH FS/200 LH LH LH
1 Lynn Haven Manufacturing has a No-Return policy for this roof curb. 2 For use with ReliaTel controlled units only. 3 Electromechanical controlled units only. 4 Kits contain all necessary parts to achieve desired level of enthalpy control. 5 For use with ReliaTel microprocessor controlled
TM TM
6 7 8
units only. Must be factory installed for Electromechanical controlled units. Used for true discharge air sensing in both heating and cooling. Required for supply air tempering. For use with ReliaTelTM controlled units only. Cannot be used in conjunction with factory installed Smoke Detector option.
downflow configuration, it installs in the unit's horizontal return duct. See Installer's Guide for more information. BAYABRD001C is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS003A), Fan Fail Switch (BAYDFPS004A), Discharge Air Sensing Kit (BAYTUBE004A or BAYTUBE005A) or Evaporator Defrost Control (Frostat) (BAYLOAM020B) unless the following options are factory installed: Frostat, Smoke Detector, Clogged Filter Switch, Fan Failure Switch, Discharge Air Sensing Kit. These factory installed options include the ReliaTelTM Options Module.
q Electromechanical controlled units only. w Interface allows 2-10 ton units with ReliaTel e r t
TM
Controls to communicates with Tracer 100, Tracker, VariTrac II, and is the preferred method of communication to Tracer Summit. Quantity 2 required for YSC036-060E. For use with ReliaTel controlled units only. Interface allows a unit with ReliaTel Controls to communicate as a Trane LonTalk device or directly with generic LonTalk Network BAS Controls.
PG 39
3 5 Ton YSC036-060E
Used with YSC036-060E_R YSC036-060E_R YSC036-060E_R YSC036-060E_R YSC036-060E_R YSC036-060E_R BAYSENS006B, 008B, 010B, & 019C YSC036-060E_R YSC036-060E_R BAYSENS019C
1 Used with Integrated Comfort Systems, any unit type. These sensors do not work with TCM. Consult BASD Marketing for them. 2 See Accessory IOM for operational characteristics.
3 Functional only with ReliaTel controls.
Thermostats:
Model Number BAYSTAT040A13 BAYBASE008A BAYBASE006A BAYSENS033A BAYSENS034A TCONT200AN11AA BAY28X1902 BAYSTAT050A BAYSTAT051A BAYSTAT052A BAYSTAT053A Mfg. Shipping Description Used with Plant Weight Programmable Thermostat YSC036-060E CK/001 1 Subbase 1-Stage Htg./Clg. BAYSTAT040A CK/001 1 Subbase 2-Stage Htg./Clg. BAYSTAT040A CK/001 1 Remote Wall Sensor BAYSTAT040A CK/001 1 Remote Duct Sensor BAYSTAT040A CK/001 1 Electronic, 1Htg/1Clg (Non Prog.) All Cooling/(Gas or Elec) TY 1 Locking Thermostat Cover Room Thermostats TY 1 for up to 4 units 2Htg/2Clg Digital Display YSC036-060E CK/001 1 Programmable Thermostat 1Htg/1Clg Digital Display Thermostat YSC036-060E CK/001 1 2Htg/2Clg Digital Display Programmable YSC036-060E CK/001 1 "TOUCHSCREEN" Thermostat 3Htg/2Clg Digital Display Programmable YSC036-060E CK/001 1 Thermostat with Relative Humidity (with Dehumidification Option) Sensing Built-In 3Htg/2Clg Digital Display Thermostat YSC036-060E CK/001 1 Return Air Remote Sensor BAYSTAT050A,051A, CK/001 1 052A,053A,051A, Wall Mounted Remote Sensor BAYSTAT050A,051A, CK/001 1 052A,053A
1 2 3
Requires use of subbase BAYBASE006A or BAYBASE008A. Do not use with Programmable Thermostats. Thermostat does not include fan or system switches..
PG 40
Capacity Heating Uncrated Output Dimensions (in.) Mfg. (BTUH) EER H W L Plant
Shipping Weight
YCH150D3L0B YCH150D3LBB Ov Motor YCH150D3LFB TCI YCH150D3H0B YCH150D3HBB Ov Motor YCH150D3HFB TCI YCH150D4L0B YCH150D4LBB Ov Motor YCH150D4LFB TCI YCH150D4H0B YCH150D4HBB Ov Motor YCH150D4HFB TCI YCH150DWL0B YCH150DWLBB Ov Motor YCH150DWLFB TCI YCH150DWH0B YCH150DWHBB Ov Motor YCH150DWHFB TCI
208-230/3/60 150,000 208-230/3/60 150,000 208-230/3/60 150,000 208-230/3/60 150,000 208-230/3/60 150,000 208-230/3/60 150,000 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000
122,000 9.6 122,000 9.6 122,000 9.6 203,000 9.6 203,000 9.6 203,000 9.6 122,000 9.6 122,000 9.6 122,000 9.6 203,000 9.6 203,000 9.6 203,000 9.6 122,000 9.6 122,000 9.6 122,000 9.6 203,000 9.6 203,000 9.6 203,000 9.6
50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50
72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72
108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108
CK/001 1599 CK/001 1694 CK/001 1600 CK/001 1599 CK/001 1694 CK/001 1600 CK/001 1599 CK/001 1694 CK/001 1600 CK/001 1599 CK/001 1694 CK/001 1600 CK/001 1599 CK/001 1694 CK/001 1600 CK/001 1599 CK/001 1694 CK/001 1600
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Liquid line drier Operating charge of R-22 Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Trane 3-D scroll compressors Dedicated horizontal and downflow designs Single side access Drum and tube gas heat exchanger Short orifice refrigerant control Hot surface ignition system Aluminized steel drum material Forced combustion Gas burner view port Negative pressure gas valve Quick-access panels with handles Internally enhanced coil tubing Sloped sheet metal drain pan Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 5 year compressor and heat exchanger warranty Optional extended warranties
PG 41
EER
Shipping Weight
YCD150D3L0B YCD150D3LAB YCD150D3LBB YCD150D3LCB YCD150D3LFB YCD150D3LGB YCD150D3H0B YCD150D3HAB YCD150D3HBB YCD150D3HCB YCD150D3HFB YCD150D3HGB YCD150D4L0B YCD150D4LAB YCD150D4LBB YCD150D4LCB YCD150D4LFB YCD150D4LGB YCD150D4H0B YCD150D4HAB YCD150D4HBB YCD150D4HCB YCD150D4HFB YCD150D4HGB YCD150DWL0B YCD150DWLAB YCD150DWLBB YCD150DWLCB YCD150DWLFB YCD150DWLGB
Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI
208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60
150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000 150,000
122,000 122,000 122,000 122,000 122,000 122,000 203,000 203,000 203,000 203,000 203,000 203,000 122,000 122,000 122,000 122,000 122,000 122,000 203,000 203,000 203,000 203,000 203,000 203,000 122,000 122,000 122,000 122,000 122,000 122,000 203,000 203,000 203,000 203,000 203,000 203,000
9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6
50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50
72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72
108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108
CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001
1580 1670 1655 1745 1581 1671 1580 1670 1655 1745 1581 1671 1580 1670 1655 1745 1581 1671 1580 1670 1655 1745 1581 1671 1580 1670 1655 1745 1581 1671 1580 1670 1655 1745 1581 1671
YCD150DWH0B YCD150DWHAB Economizer YCD150DWHBB Ov Motor YCD150DWHCB Econ/OvMtr YCD150DWHFB TCI YCD150DWHGB Econ/TCI
PG 42
Model Mfg. Shipping Number Description Used With Plant Weight Extended Warranties (1 yr - 5 yr See Extended Warranty Section) BAYABRD002B ReliaTelTM Options Module See Note 6 CK/001 2 BAYCURB026B15 Downflow Roof Curb YCD150D CK/001 165 BAYDMPR029C 0-25% Manual Outside Air Damper YCD150D CK/001 32 YCH150D BAYDMPR057A Motorized Outside Air Damper YCD150D CK/001 35 YCH150D BAYECON089A Downflow Economizer with Barometric Relief YCD150D CK/001 90 BAYECON091A Horizontal Economizer YCH150D CK/001 110 BAYGARD043B Tool-less Condenser Coil Hail Guard YC*150D CK/001 50 BAYSTAT023 Remote Potentiometer BAYECON089A,091A, CK/001 1 BAYDMPR057A BAYPWRX029A Power Exhaust for use YCD150D3 CK/001 75 with Downflow Economizer/ 230V BAYPWRX030A Power Exhaust for use YCD150D4 CK/001 75 with Downflow Economizer/ 460V BAYPWRX031A Power Exhaust for use YCD150DW CK/001 75 with Downflow Economizer/ 575V BAYHSMT039B 5 HP Oversize Motor Kit YC*1503,4 CK/001 95 BAYHSMT040B 5 HP Oversize Motor Kit YCD150DW CK/001 95 YCH150DW BAYLPKT018A LP Conversion Kit YCD150D CK/001 1 YCH150D BAYSERV001A Selective Resistance YCD150D CK/001 2 Service Tester YCH150D BAYSENS016A Temperature Sensor YCD150D CK/001 1 YCH150D BAYFRST003A3 High Temperature Stat YCD150D CK/001 1 YCH150D BAYENTH007A2 Reference Enthalpy Kit BAYECON089A CK/001 1 BAYECON091A BAYECON089A CK/001 1 BAYENTH008A2 Comparative Enthalpy Kit BAYECON091A BAYDFPS005A7 Clogged FIlter Switch YCD150D CK/001 1 YCH150D BAYDFPS006A7 Fan Failure Switch BAYECON089A,091A CK/001 1 BAYDMPR057A
BAYLOAM023A
BAYTUBE008A4 BAYTUBE009A4
BAYVNOR002B
YCD150D YCH150D
CK/001 CK/001
1 1
2
1 For downflow use only. Cannot be adapted for horizontal units. 2 Kits contain all necessary parts to achieve desired level of enthalpy control. 3 Must be used with either field or factory installed TCI (Trane Communication Interface). 4 Used for true discharge air sensing in both heating and cooling models. Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B). 5 Clarksville Manufacturing has a no-return policy for this roof curb. 6 BAYABRD002B is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS005A), Fan Fail Switch (BAYDFPS006A), Discharge Air Sensing Kit (BAYTUBE008A or BAYTUBE009A), Frostat (BAYLOAM023A), Ventilation Override (BAYVNOR002B). 7 Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B).
FOR CHOICE OF ZONE SENSORS (MICRO THERMOSTATS) SEE LAST PAGE BEFORE HIGH EFFICIENCY GAS/ELECTRIC PG 43 Effective date: January 1, 2007
15 Ton YCH180B
Specifications: Horizontal
Factory Model Installed Number Option YCH180B3L0H YCH180B3LBH Ov Motor YCH180B3LFH TCI YCH180B3H0H YCH180B3HBH Ov Motor YCH180B3HFH TCI YCH180B4L0H YCH180B4LBH Ov Motor YCH180B4LFH TCI YCH180B4H0H YCH180B4HBH Ov Motor YCH180B4HFH TCI YCH180BWL0H YCH180BWLBH Ov Motor YCH180BWLFH TCI YCH180BWH0H YCH180BWHBH Ov Motor YCH180BWHFH TCI Capacity Power Cooling Supply (BTUH) 208-230/3/60 182,000 208-230/3/60 182,000 208-230/3/60 182,000 208-230/3/60 182,000 208-230/3/60 182,000 208-230/3/60 182,000 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 Capacity Heating Output (BTUH) EER 203,000 9.7 203,000 9.7 203,000 9.7 284,000 9.7 284,000 9.7 284,000 9.7 203,000 9.7 203,000 9.7 203,000 9.7 284,000 9.7 284,000 9.7 284,000 9.7 203,000 9.7 203,000 9.7 203,000 9.7 284,000 9.7 284,000 9.7 284,000 9.7
Uncrated Dimensions (in.) H W L 50 72 108 50 72 108 50 72 108 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108
Mfg. Shipping Plant Weight CK/001 1906 CK/001 2001 CK/001 1907 CK/001 1906 CK/001 2001 CK/001 1907 CK/001 1906 CK/001 2001 CK/001 1907 CK/001 1906 CK/001 2001 CK/001 1907 CK/001 1906 CK/001 2001 CK/001 1907 CK/001 1906 CK/001 2001 CK/001 1907
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Liquid line drier Operating charge of R-22 Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Trane 3-D scroll compressors Dedicated horizontal and downflow designs Single side access Drum and tube gas heat exchanger Short orifice refrigerant control Hot surface ignition system Aluminized steel drum material Forced combustion Gas burner view port Negative pressure gas valve Quick-access panels with handles Internally enhanced coil tubing Sloped sheet metal drain pan Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 5 year compressor and heat exchanger warranty Optional extended warranties
PG 44
15 Ton YCD180B
Specifications: Downflow
Model Number
YCD180B3L0H YCD180B3LAH YCD180B3LBH YCD180B3LCH YCD180B3LFH YCD180B3LGH YCD180B3H0H YCD180B3HAH YCD180B3HBH YCD180B3HCH YCD180B3HFH YCD180B3HGH YCD180B4L0H YCD180B4LAH YCD180B4LBH YCD180B4LCH YCD180B4LFH YCD180B4LGH YCD180B4H0H YCD180B4HAH YCD180B4HBH YCD180B4HCH YCD180B4HFH YCD180B4HGH YCD180BWL0H YCD180BWLAH YCD180BWLBH YCD180BWLCH YCD180BWLFH YCD180BWLGH YCD180BWH0H YCD180BWHAH YCD180BWHBH YCD180BWHCH YCD180BWHFH YCD180BWHGH
Power Supply
208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60
Capacity Capacity Heating Uncrated Cooling Output Dimensions (in.) Mfg. Shipping (BTUH) (BTUH) EER H W L Plant Weight
182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 182,000 203,000 203,000 203,000 203,000 203,000 203,000 284,000 284,000 284,000 284,000 284,000 284,000 203,000 203,000 203,000 203,000 203,000 203,000 284,000 284,000 284,000 284,000 284,000 284,000 203,000 203,000 203,000 203,000 203,000 203,000 284,000 284,000 284,000 284,000 284,000 284,000 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 1892 2007 1967 2082 1893 2008 1892 2007 1967 2082 1893 2008 1892 2007 1967 2082 1893 2008 1892 2007 1967 2082 1893 2008 1892 2007 1967 2082 1893 2008 1892 2007 1967 2082 1893 2008
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Short orifice refrigerant control Liquid line drier
Operating charge of R-22 Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Trane 3-D scroll compressors Dedicated downflow design Single side access Drum and tube gas heat exchanger Hot surface ignition system Aluminized steel drum material Forced combustion Gas burner view port PG 45
Negative pressure gas valve Quick-access panels with handles Sloped sheet metal drain pan Internally enhanced coil tubing Low ambient cooling to 0F standard colored and numbered wiring UL listed and CSA certified 5 year compressor and heat exchanger warranty
BAYTUBE008A4 BAYTUBE009A4
BAYVNOR002B
YCD180B YCH180B
CK/001 CK/001
1 1
2
1 For downflow use only. Cannot be adapted for horizontal units. 2 Kits contain all necessary parts to achieve desired level of enthalpy control. 3 Must be used with either field or factory installed TCI (Trane Communication Interface). 4 Used for true discharge air sensing in both heating and cooling models. Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B). 5 Clarksville Manufacturing has a no-return policy for this roof curb. 6 High static drive and oversized motors are mutually exclusive. Do not combine. 7 BAYABRD002B is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS005A), Fan Fail Switch (BAYDFPS006A), Discharge Air Sensing Kit (BAYTUBE008A or BAYTUBE009A), Frostat (BAYLOAM023A), Ventilation Override (BAYVNOR002B). 8 Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B).
PG 46 Effective date: January 1, 2007
17-1/2Ton YCH210C
Specifications: Horizontal
Model Number Factory Installed Option Power Supply Capacity Capacity Heating Cooling Output (BTUH) (BTUH) EER
YCH210C3L0E YCH210C3LBE Ov Motor YCH210C3LFE TCI YCH210C3H0E YCH210C3HBE Ov Motor YCH210C3HFE TCI YCH210C4L0E YCH210C4LBE Ov Motor YCH210C4LFE TCI YCH210C4H0E YCH210C4HBE Ov Motor YCH210C4HFE TCI YCH210CWL0E YCH210CWLBE Ov Motor YCH210CWLFE TCI YCH210CWH0E YCH210CWHBE Ov Motor YCH210CWHFE TCI
208-230/3/60 210,000 203,000 9.6 208-230/3/60 210,000 203,000 9.6 208-230/3/60 210,000 203,000 9.6 208-230/3/60 210,000 284,000 9.6 208-230/3/60 210,000 284,000 9.6 208-230/3/60 210,000 284,000 9.6 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 210,000 203,000 9.6 210,000 203,000 9.6 210,000 203,000 9.6 210,000 284,000 9.6 210,000 284,000 9.6 210,000 284,000 9.6 210,000 203,000 9.6 210,000 203,000 9.6 210,000 203,000 9.6 210,000 284,000 9.6 210,000 284,000 9.6 210,000 284,000 9.6
50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50
72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72
108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108
CK/001 1987 CK/001 2097 CK/001 1988 CK/001 1987 CK/001 2097 CK/001 1988 CK/001 1987 CK/001 2097 CK/001 1988 CK/001 1987 CK/001 2097 CK/001 1988 CK/001 1987 CK/001 2097 CK/001 1988 CK/001 1987 CK/001 2097 CK/001 1988
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Liquid line drier Operating charge of R-22 Short orifice refrigerant control Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Trane 3-D scroll compressors Dedicated horizontal and downflow designs Single side access Drum and tube gas heat exchanger Hot surface ignition system Aluminized steel drum material Forced combustion Gas burner view port Negative pressure gas valve Quick-access panels with handles Sloped sheet metal drain pan Internally enhanced coil tubing Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 5 year compressor and heat exchanger warranty on 17-1/2 ton units Optional extended warranties
PG 47
17-1/2Ton YCD210C
Specifications: Downflow
Model Number YCD210C3L0E YCD210C3LAE YCD210C3LBE YCD210C3LCE YCD210C3LFE YCD210C3LGE YCD210C3H0E YCD210C3HAE YCD210C3HBE YCD210C3HCE YCD210C3HFE YCD210C3HGE YCD210C4L0E YCD210C4LAE YCD210C4LBE YCD210C4LCE YCD210C4LFE YCD210C4LGE YCD210C4H0E YCD210C4HAE YCD210C4HBE YCD210C4HCE YCD210C4HFE YCD210C4HGE YCD210CWL0E YCD210CWLAE YCD210CWLBE YCD210CWLCE YCD210CWLFE YCD210CWLGE YCD210CWH0E YCD210CWHAE YCD210CWHBE YCD210CWHCE YCD210CWHFE YCD210CWHGE Factory Installed Option Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Power Supply 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 Capacity Cooling (BTUH) 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 210,000 Capacity Heating Output (BTUH) EER 203,000 9.6 203,000 9.6 203,000 9.6 203,000 9.6 203,000 9.6 203,000 9.6 284,000 284,000 284,000 284,000 284,000 284,000 203,000 203,000 203,000 203,000 203,000 203,000 284,000 284,000 284,000 284,000 284,000 284,000 203,000 203,000 203,000 203,000 203,000 203,000 284,000 284,000 284,000 284,000 284,000 284,000 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 Uncrated Dimensions (in.) H W L 50 72 108 50 72 108 50 72 108 50 72 108 50 72 108 50 72 108 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108
Mfg. Shipping Plant Weight CK/001 1973 CK/001 2088 CK/001 2083 CK/001 2198 CK/001 1974 CK/001 2089 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 1973 2088 2083 2198 1974 2089 1973 2088 2083 2198 1974 2089 1973 2088 2083 2198 1974 2089 1973 2088 2083 2198 1974 2089 1973 2088 2083 2198 1974 2089
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Short orifice refrigerant control Liquid line drier Operating charge of R-22 Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Trane 3-D scroll compressors Dedicated downflow design Single side access Drum and tube gas heat exchanger Hot surface ignition system Aluminized steel drum material Forced combustion PG 48 Gas burner view port Negative pressure gas valve Sloped sheet metal drain pan Quick-access panels with handles Internally enhanced coil tubing Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 5 year compressor and heat exchanger warranty Effective date: January 1, 2007
BAYTUBE008A5 BAYTUBE009A5
BAYVNOR002B
YCD210C YCH210C
CK/001 CK/001
1 1
2
1 For downflow use only. Cannot be adapted for horizontal units. 2 Kits contain all necessary parts to achieve desired level of enthalpy control. 3 Must be used with either field or factory installed TCI (Trane Communication Interface). 4 Low static drive and oversized motors are mutually exclusive. Do not combine. 5 Used for true discharge air sensing in both heating and cooling models. Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B). 6 Clarksville Manufacturing has a no-return policy for this roof curb. 7 BAYABRD002B is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS005A), Fan Fail Switch (BAYDFPS006A), Discharge Air Sensing Kit (BAYTUBE008A or BAYTUBE009A), Frostat (BAYLOAM023A), Ventilation Override (BAYVNOR00B). 8 Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B).
PG 49 Effective date: January 1, 2007
20 Ton YCH240B
Specifications: Horizontal
Model Number YCH240B3L0J YCH240B3LBJ YCH240B3LFJ Factory Installed Option Ov Motor TCI Capacity Power Cooling Supply (BTUH) 208-230/3/60 242,000 208-230/3/60 242,000 208-230/3/60 242,000 Capacity Heating Output (BTUH) 203,000 203,000 203,000 Uncrated Dimensions (in.) EER H W L 9.5 54 86 123 9.5 54 86 123 9.5 54 86 123 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123
Mfg. Shipping Plant Weight CK/001 2484 CK/001 2574 CK/001 2485 CK/001 2484 CK/001 2574 CK/001 2485 CK/001 2484 CK/001 2574 CK/001 2485 CK/001 2484 CK/001 2574 CK/001 2485 CK/001 2484 CK/001 2574 CK/001 2485 CK/001 2484 CK/001 2574 CK/001 2485
YCH240B3H0J 208-230/3/60 242,000 YCH240B3HBJ Ov Motor 208-230/3/60 242,000 YCH240B3HFJ TCI 208-230/3/60 242,000 YCH240B4L0J YCH240B4LBJ YCH240B4LFJ 460/3/60 Ov Motor 460/3/60 TCI 460/3/60 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000
324,000 9.5 324,000 9.5 324,000 9.5 203,000 9.5 203,000 9.5 203,000 9.5 324,000 9.5 324,000 9.5 324,000 9.5 203,000 9.5 203,000 9.5 203,000 9.5 324,000 9.5 324,000 9.5 324,000 9.5
YCH240B4H0J 460/3/60 YCH240B4HBJ Ov Motor 460/3/60 YCH240B4HFJ TCI 460/3/60 YCH240BWL0J 575/3/60 YCH240BWLBJ Ov Motor 575/3/60 YCH240BWLFJ TCI 575/3/60 YCH240BWH0J 575/3/60 YCH240BWHBJ Ov Motor 575/3/60 YCH240BWHFJ TCI 575/3/60
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Liquid line drier Operating charge of R-22 Short orifice refrigerant control Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Trane 3-D scroll compressors Dedicated horizontal and downflow designs Single side access Drum and tube gas heat exchanger Hot surface ignition system Aluminized steel drum material Forced combustion Gas burner view port Negative pressure gas valve Sloped sheet metal drain pan Quick-access panels with handles Internally enhanced coil tubing Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 1 year compressor and heat exchanger warranty Optional extended warranties
PG 50
20 Ton YCD240B
Specifications: Downflow
Model Number
YCD240B3L0J YCD240B3LAJ YCD240B3LBJ YCD240B3LCJ YCD240B3LFJ YCD240B3LGJ YCD240B3H0J YCD240B3HAJ YCD240B3HBJ YCD240B3HCJ YCD240B3HFJ YCD240B3HGJ YCD240B4L0J YCD240B4LAJ YCD240B4LBJ YCD240B4LCJ YCD240B4LFJ YCD240B4LGJ YCD240B4H0J YCD240B4HAJ YCD240B4HBJ YCD240B4HCJ YCD240B4HFJ YCD240B4HGJ YCD240BWL0J YCD240BWLAJ YCD240BWLBJ YCD240BWLCJ YCD240BWLFJ YCD240BWLGJ YCD240BWH0J YCD240BWHAJ YCD240BWHBJ YCD240BWHCJ YCD240BWHFJ YCD240BWHGJ
Power Supply
208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60
Capacity Capacity Heating Uncrated Cooling Output Dimensions (in.) Mfg. Shipping (BTUH) (BTUH) EER H W L Plant Weight
242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 242,000 203,000 203,000 203,000 203,000 203,000 203,000 324,000 324,000 324,000 324,000 324,000 324,000 203,000 203,000 203,000 203,000 203,000 203,000 324,000 324,000 324,000 324,000 324,000 324,000 203,000 203,000 203,000 203,000 203,000 203,000 324,000 324,000 324,000 324,000 324,000 324,000 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 2468 2603 2558 2693 2469 2604 2468 2603 2558 2693 2469 2604 2468 2603 2558 2693 2469 2604 2468 2603 2558 2693 2469 2604 2468 2603 2558 2693 2469 2604 2468 2603 2558 2693 2469 2604
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Short orifice refrigerant control
Liquid line drier Operating charge of R-22 Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Trane 3-D scroll compressors Dedicated downflow design Single side access Drum and tube gas heat exchanger Hot surface ignition system Aluminized steel drum material
Sloped sheet metal drain pan Forced combustion Gas burner view port Negative pressure gas valve Quick-access panels with handles Internally enhanced coil tubing Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 1 year compressor and heat exchanger warranty
PG 51
25 Ton YCH300B
Specifications: Horizontal
Factory Model Installed Number Option YCH300B3L0H YCH300B3LFH TCI YCH300B3H0H YCH300B3HFH TCI YCH300B4L0H YCH300B4LFH TCI YCH300B4H0H YCH300B4HFH TCI YCH300BWL0H YCH300BWLFH TCI YCH300BWH0H YCH300BWHFH TCI Power Supply 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 Capacity Cooling (BTUH) 290,000 290,000 290,000 290,000 290,000 290,000 290,000 290,000 290,000 290,000 290,000 290,000
Capacity Heating Uncrated Output Dimensions (in.) (BTUH) EER H W L 203,000 9.7 54 86 123 203,000 9.7 54 86 123 324,000 324,000 203,000 203,000 324,000 324,000 203,000 203,000 324,000 324,000 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 54 54 54 54 54 54 54 54 54 54 86 86 86 86 86 86 86 86 86 86 123 123 123 123 123 123 123 123 123 123
Mfg. Shipping Plant Weight CK/001 2541 CK/001 2542 CK/001 2541 CK/001 2542 CK/001 2541 CK/001 2542 CK/001 2541 CK/001 2542 CK/001 2541 CK/001 2542 CK/001 2541 CK/001 2542
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Short orifice refrigerant control Liquid line drier Operating charge of R-22 Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Trane 3-D scroll compressors Dedicated horizontal design Single side access Drum and tube gas heat exchanger Hot surface ignition system Aluminized steel drum material Sloped sheet metal drain pan Forced combustion Gas burner view port Negative pressure gas valve Quick-access panels with handles Internally enhanced coil tubing Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 1 year compressor and heat exchanger warranty
PG 52
25 Ton YCD300B
Specifications: Downflow
Model Number YCD300B3L0H YCD300B3LAH YCD300B3LFH YCD300B3LGH YCD300B3H0H YCD300B3HAH YCD300B3HFH YCD300B3HGH YCD300B4L0H YCD300B4LAH YCD300B4LFH YCD300B4LGH YCD300B4H0H YCD300B4HAH YCD300B4HFH YCD300B4HGH YCD300BWL0H YCD300BWLAH YCD300BWLFH YCD300BWLGH Factory Installed Option Economizer TCI Econ/TCI Economizer TCI Econ/TCI Economizer TCI Econ/TCI Economizer TCI Econ/TCI Economizer TCI Econ/TCI Power Supply 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 Capacity Cooling (BTUH) 246,000 246,000 246,000 246,000 246,000 246,000 246,000 246,000 246,000 246,000 246,000 246,000 246,000 246,000 246,000 246,000 246,000 246,000 246,000 246,000 246,000 246,000 246,000 246,000 Capacity Heating Output (BTUH) 203,000 203,000 203,000 203,000 324,000 324,000 324,000 324,000 203,000 203,000 203,000 203,000 324,000 324,000 324,000 324,000 203,000 203,000 203,000 203,000 324,000 324,000 324,000 324,000
Uncrated Dimensions (in.) EER H W L 9.7 54 86 123 9.7 54 86 123 9.7 54 86 123 9.7 54 86 123 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123
Mfg. Shipping Plant Weight CK/001 2525 CK/001 2660 CK/001 2526 CK/001 2661 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 2525 2660 2526 2661 2525 2660 2526 2661 2525 2660 2526 2661 2525 2660 2526 2661 2525 2660 2526 2661
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Short orifice refrigerant control Liquid line drier Operating charge of R-22 Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Trane 3-D scroll compressors Dedicated downflow design Single side access Drum and tube gas heat exchanger Hot surface ignition system Aluminized steel drum material Sloped sheet metal drain pan Forced combustion Gas burner view port Negative pressure gas valve Quick-access panels with handles Internally enhanced coil tubing Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 1 year compressor and heat exchanger warranty
PG 53
Shipping Weight
2 235 32 75 135 175 60 60 1 95 95 95 90 90 90 15 15 2 1 2 1 1 1 1 1 1 3 1 1 2
1 For downflow use only. Cannot be adapted for horizontal units. 2 Kits contain all necessary parts to achieve desired level of enthalpy control. 3 Must be used with either field or factory installed TCI (Trane Communication Interface). 4 High static drive and oversized motors are mutually exclusive. Do not combine. 5 Used for true discharge air sensing in both heating and cooling models. Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B). 6 Clarksville Manufacturing has a no-return policy for this roof curb. 7 BAYABRD002B is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS005A), Fan Fail Switch (BAYDFPS006A), Discharge Air Sensing Kit (BAYTUBE008A or BAYTUBE009A), Frostat (BAYLOAM023A), Ventilation Override (BAYVNOR002B). 8 Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B).
Extended Warranties (1 yr - 5 yr See Extended Warranty Section) BAYABRD002B ReliaTelTM Options Module See Note BAYCURB027B Downflow Roof Curb YCD240-300B BAYDMPR029C 0-25% Manual Outside Air Damper YCD240-300B YCH240-300B BAYDMPR058A Motorized Outside Air Damper YCD240-300B YCH240-300B BAYECON090A Downflow Economizer YCD240-300B with Barometric Relief BAYECON092A Horizontal Economizer YCH240-300B BAYGARD045A Tool-less Condenser Coil Hail Guard YC*240 BAYGARD047A Tool-less Condenser Coil Hail Guard YC*300B BAYSTAT023 Remote Potentiometer BAYECON090A,092A BAYDMPR058A BAYPWRX029A Power Exhaust for use YCD240-300B3 with Downflow Economizer 230V BAYPWRX030A Power Exhaust for use YCD240-300B4 with Downflow Economizer 460V BAYPWRX031A Power Exhaust for use YCD240-300BW with Downflow Economizer 575V BAYHSMT042A 7 HP Oversize Motor Kit YCD240BW/YCH240BW BAYHSMT098A 7 HP Oversize Motor Kit YC*240B3 BAYHSMT099A 7 HP Oversize Motor Kit YC*240B4 BAYHSDR005B High Static Drive YCD240B/YCH240B BAYHSDR010A High Static Drive YCD300B/YCH300B BAYLSDR002A Low Static Drive YCD300B/YCH300B BAYLPKT018A LP Conversion Kit YCD240-300B/YCH240-300B BAYSERV001A Selective Resistance Service Tester YCD240-300B/YCH240-300B BAYSENS016A Temperature Sensor YCD240-300B/YCH240-300B BAYFRST003A High Temperature Stat YCD240-300B/YCH240-300B BAYENTH007A Reference Enthalpy Kit BAYECON090A BAYECON092A BAYENTH008A Comparative Enthalpy Kit BAYECON090A BAYECON092A BAYDFPS005A Clogged Filter Switch YCD240-300B YCH240-300B Clogged Filter Switch BAYECON090A,092A BAYDFPS006A BAYDMPR058A BAYLOAM023A Evaporator Defrost YC*240-300B Control (Frostat) w/ReliaTel Options Module BAYTUBE008A Discharge Air Sensing Kit YCD240-300B BAYTUBE009A Discharge Air Sensing Kit YCH240-300B BAYVNOR002B Ventilation Override Kit YC*240-300B w/ReliaTel Options Module
16
4 4 4 4 4
3 2 2 8 8 5 5
PG 54
EER
Shipping Weight
YCD150E3L0A YCD150E3LAA YCD150E3LBA YCD150E3LCA YCD150E3LFA YCD150E3LGA YCD150E3H0A YCD150E3HAA YCD150E3HBA YCD150E3HCA YCD150E3HFA YCD150E3HGA YCD150E4L0A YCD150E4LAA YCD150E4LBA YCD150E4LCA YCD150E4LFA YCD150E4LGA YCD150E4H0A YCD150E4HAA YCD150E4HBA YCD150E4HCA YCD150E4HFA YCD150E4HGA YCD150EWL0A YCD150EWLAA YCD150EWLBA YCD150EWLCA YCD150EWLFA YCD150EWLGA
Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI
208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60
148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000
122,000 122,000 122,000 122,000 122,000 122,000 203,000 203,000 203,000 203,000 203,000 203,000 122,000 122,000 122,000 122,000 122,000 122,000 203,000 203,000 203,000 203,000 203,000 203,000 122,000 122,000 122,000 122,000 122,000 122,000 203,000 203,000 203,000 203,000 203,000 203,000
11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0
50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50
72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72
108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108
CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001
1950 2040 2035 2100 1950 2040 2035 2100 1950 2040 2035 2035 1950 2040 2035 2100 1950 2040 2035 2100 1950 2040 1581 2035 1950 2040 2035 2100 2035 2040 2035 2100 1950 2040 2035 2035
YCD150EWH0A YCD150EWHAA Economizer YCD150EWHBA Ov Motor YCD150EWHCA Econ/OvMtr YCD150EWHFA TCI YCD150EWHGA Econ/TCI
PG 55
Capacity Heating Uncrated Output Dimensions (in.) Mfg. (BTUH) EER H W L Plant
Shipping Weight
YCH150E3L0A YCH150E3LBA Ov Motor YCH150E3LFA TCI YCH150E3H0A YCH150E3HBA Ov Motor YCH150E3HFA TCI YCH150E4L0A YCH150E4LBA Ov Motor YCH150E4LFA TCI YCH150E4H0A YCH150E4HBA Ov Motor YCH150E4HFA TCI YCH150EWL0A YCH150EWLBA Ov Motor YCH150EWLFA TCI YCH150EWH0A YCH150EWHBA Ov Motor YCH150EWHFA TCI
208-230/3/60 148,000 208-230/3/60 148,000 208-230/3/60 148,000 208-230/3/60 148,000 208-230/3/60 148,000 208-230/3/60 148,000 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000 148,000
122,000 11.0 50 122,000 11.0 50 122,000 11.0 50 203,000 11.0 50 203,000 11.0 50 203,000 11.0 50 122,000 11.0 50 122,000 11.0 50 122,000 11.0 50 203,000 11.0 50 203,000 11.0 50 203,000 11.0 50 122,000 11.0 50 122,000 11.0 50 122,000 11.0 50 203,000 11.0 50 203,000 11.0 50 203,000 11.0 50
72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72
108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108
CK/001 1950 CK/001 2040 CK/001 1955 CK/001 1950 CK/001 2040 CK/001 1955 CK/001 1950 CK/001 2040 CK/001 1955 CK/001 1950 CK/001 2040 CK/001 1955 CK/001 1950 CK/001 2040 CK/001 1955 CK/001 1950 CK/001 2040 CK/001 1955
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Liquid line drier Operating charge of R-410A Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Trane 3-D scroll compressors Dedicated horizontal and downflow designs Single side access Drum and tube gas heat exchanger Short orifice refrigerant control Hot surface ignition system Aluminized steel drum material Forced combustion Gas burner view port Negative pressure gas valve Quick-access panels with handles Internally enhanced coil tubing Sloped sheet metal drain pan Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 5 year compressor and heat exchanger warranty
PG 56
Mfg. Shipping Description Used With Plant Weight ReliaTelTM Options Module See Note 6 CK/001 2 Downflow Roof Curb YCD150E CK/001 165 0-25% Manual Outside Air Damper YC*150E CK/001 32 Motorized Outside Air Damper YC*150E CK/001 35 Downflow Economizer with Barometric Relief YCD150E CK/001 90 Horizontal Economizer YCH150E CK/001 110 Tool-less Condenser Coil Hail Guard YC*150E CK/001 50 Remote Potentiometer BAYECON089A,091A, CK/001 1 BAYDMPR057A Power Exhaust for use YCD150E3 CK/001 75 with Downflow Economizer/ 230V Power Exhaust for use YCD150E4 CK/001 75 with Downflow Economizer/ 460V Power Exhaust for use YCD150EW CK/001 75 with Downflow Economizer/ 575V 5 HP Oversize Motor Kit YC*150E3,4 CK/001 95 5 HP Oversize Motor Kit YCD150EW CK/001 95 YCH150EW LP Conversion Kit YC*150E CK/001 1 Selective Resistance Service Tester YC*150E CK/001 2 Temperature Sensor YC*150E CK/001 1 High Temperature Stat YC*150E CK/001 1 Reference Enthalpy Kit BAYECON089A CK/001 1 BAYECON091A Comparative Enthalpy Kit BAYECON089A CK/001 1 BAYECON091A Clogged FIlter Switch YC*150E CK/001 1 Fan Failure Switch BAYECON089A,091A CK/001 1 BAYDMPR057A
Evaporator Defrost Control (Frostat) YC*150E CK/001 w/ReliaTel Options Module 3
BAYTUBE008A4 BAYTUBE009A4
BAYVNOR002B
YCD150E YCH150E
1 For downflow use only. Cannot be adapted for horizontal units. 2 Kits contain all necessary parts to achieve desired level of enthalpy control. 3 Must be used with either field or factory installed TCI (Trane Communication Interface). 4 Used for true discharge air sensing in both heating and cooling models. Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B). 5 Clarksville Manufacturing has a no-return policy for this roof curb. 6 BAYABRD002B is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS005A), Fan Fail Switch (BAYDFPS006A), Discharge Air Sensing Kit (BAYTUBE008A or BAYTUBE009A), Frostat (BAYLOAM023A), Ventilation Override (BAYVNOR002B). 7 Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B).
1 1
2
FOR CHOICE OF ZONE SENSORS (MICRO THERMOSTATS) SEE LAST PAGE BEFORE HIGH EFFICIENCY GAS/ELECTRIC
PG 57
15 Ton YCH180E
Specifications: Horizontal
Factory Model Installed Number Option YCH180E3L0A YCH180E3LBA Ov Motor YCH180E3LFA TCI YCH180E3H0A YCH180E3HBA Ov Motor YCH180E3HFA TCI YCH180E4L0A YCH180E4LBA Ov Motor YCH180E4LFA TCI YCH180E4H0A YCH180E4HBA Ov Motor YCH180E4HFA TCI YCH180EWL0A YCH180EWLBA Ov Motor YCH180EWLFA TCI YCH180EWH0A YCH180EWHBA Ov Motor YCH180EWHFA TCI Capacity Power Cooling Supply (BTUH) 208-230/3/60 178,000 208-230/3/60 178,000 208-230/3/60 178,000 208-230/3/60 178,000 208-230/3/60 178,000 208-230/3/60 178,000 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 Capacity Heating Output (BTUH) EER 203,000 11.0 203,000 11.0 203,000 11.0
Uncrated Dimensions (in.) H W L 54 86 123 54 86 123 54 86 123 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123
Mfg. Shipping Plant Weight CK/001 2475 CK/001 2575 CK/001 2477 CK/001 2475 CK/001 2575 CK/001 2477 CK/001 2475 CK/001 2575 CK/001 2477 CK/001 2475 CK/001 2575 CK/001 2477 CK/001 2475 CK/001 2575 CK/001 2477 CK/001 2475 CK/001 2575 CK/001 2477
284,000 11.0 54 284,000 11.0 54 284,000 11.0 54 203,000 11.0 54 203,000 11.0 54 203,000 11.0 54 284,000 11.0 54 284,000 11.0 54 284,000 11.0 54 203,000 11.0 54 203,000 11.0 54 203,000 11.0 54 284,000 11.0 54 284,000 11.0 54 284,000 11.0 54
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Liquid line drier Operating charge of R-410A Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Trane 3-D scroll compressors Dedicated horizontal and downflow designs Single side access Drum and tube gas heat exchanger Short orifice refrigerant control Hot surface ignition system Aluminized steel drum material Forced combustion Gas burner view port Negative pressure gas valve Quick-access panels with handles Internally enhanced coil tubing Sloped sheet metal drain pan Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 5 year compressor and heat exchanger warranty
PG 58
15 Ton YCD180E
Specifications: Downflow
Model Number
YCD180E3L0A YCD180E3LAA YCD180E3LBA YCD180E3LCA YCD180E3LFA YCD180E3LGA YCD180E3H0A YCD180E3HAA YCD180E3HBA YCD180E3HCA YCD180E3HFA YCD180E3HGA YCD180E4L0A YCD180E4LAA YCD180E4LBA YCD180E4LCA YCD180E4LFA YCD180E4LGA YCD180E4H0A YCD180E4HAA YCD180E4HBA YCD180E4HCA YCD180E4HFA YCD180E4HGA YCD180EWL0A YCD180EWLAA YCD180EWLBA YCD180EWLCA YCD180EWLFA YCD180EWLGA YCD180EWH0A YCD180EWHAA YCD180EWHBA YCD180EWHCA YCD180EWHFA YCD180EWHGA
Power Supply
208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60
Capacity Capacity Heating Uncrated Cooling Output Dimensions (in.) Mfg. Shipping (BTUH) (BTUH) EER H W L Plant Weight
178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 178,000 203,000 203,000 203,000 203,000 203,000 203,000 284,000 284,000 284,000 284,000 284,000 284,000 203,000 203,000 203,000 203,000 203,000 203,000 284,000 284,000 284,000 284,000 284,000 284,000 203,000 203,000 203,000 203,000 203,000 203,000 284,000 284,000 284,000 284,000 284,000 284,000 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 2475 2585 2520 2655 2476 2656 2475 2585 2520 2655 2476 2656 2475 2585 2520 2655 2476 2656 2475 2585 2520 2655 2476 2656 2475 2585 2520 2655 2476 2656 2475 2585 2520 2655 2476 2656
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Short orifice refrigerant control Liquid line drier
Operating charge of R-410A Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Trane 3-D scroll compressors Dedicated downflow design Single side access Drum and tube gas heat exchanger Hot surface ignition system Aluminized steel drum material Forced combustion
Gas burner view port Negative pressure gas valve Quick-access panels with handles Sloped sheet metal drain pan Internally enhanced coil tubing Low ambient cooling to 0F standard colored and numbered wiring UL listed and CSA certified 5 year compressor and heat exchanger warranty
PG 59
Description ReliaTelTM Options Module Downflow Roof Curb 0-25% Manual Outside Air Damper Motorized Outside Air Damper Downflow Economizer with Barometric Relief Horizontal Economizer Tool-less Condenser Coil Hail Guard Remote Potentiometer Power Exhaust for use with Downflow Economizer/ 230V Power Exhaust for use with Downflow Economizer/ 460V Power Exhaust for use with Downflow Economizer/ 575V 5 HP Oversize Motor Kit 5 HP Oversize Motor Kit High Static Drive LP Conversion Kit Selective Resistance Service Tester Temperature Sensor High Temperature Stat Reference Enthalpy Kit Comparative Enthalpy Kit Clogged FIlter Switch Fan Failure Switch
Evaporator Defrost Control (Frostat)
BAYTUBE008A4 BAYTUBE009A4
BAYVNOR002B
CK/001 CK/001
1 1
2
1 For downflow use only. Cannot be adapted for horizontal units. 2 Kits contain all necessary parts to achieve desired level of enthalpy control. 3 Must be used with either field or factory installed TCI (Trane Communication Interface). 4 Used for true discharge air sensing in both heating and cooling models. Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B). 5 Clarksville Manufacturing has a no-return policy for this roof curb. 6 High static drive and oversized motors are mutually exclusive. Do not combine. 7 BAYABRD002B is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS005A), Fan Fail Switch (BAYDFPS006A), Discharge Air Sensing Kit (BAYTUBE008A or BAYTUBE009A), Frostat (BAYLOAM023A), Ventilation Override (BAYVNOR002B). 8 Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B).
PG 60
17-1/2Ton YCH210E
Specifications: Horizontal
Model Number Factory Installed Option Power Supply Capacity Capacity Heating Cooling Output (BTUH) (BTUH) EER
YCH210E3L0A YCH210E3LBA Ov Motor YCH210E3LFA TCI YCH210E3H0A YCH210E3HBA Ov Motor YCH210E3HFA TCI YCH210E4L0A YCH210E4LBA Ov Motor YCH210E4LFA TCI YCH210E4H0A YCH210E4HBA Ov Motor YCH210E4HFA TCI YCH210EWL0A YCH210EWLBA Ov Motor YCH210EWLFA TCI YCH210EWH0A YCH210EWHBA Ov Motor YCH210EWHFA TCI
208-230/3/60 198,000 203,000 11.0 54 208-230/3/60 198,000 203,000 11.0 54 208-230/3/60 198,000 203,000 11.0 54 208-230/3/60 198,000 284,000 11.0 54 208-230/3/60 198,000 284,000 11.0 54 208-230/3/60 198,000 284,000 11.0 54 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 198,000 203,000 11.0 54 198,000 203,000 11.0 54 198,000 203,000 11.0 54 198,000 284,000 11.0 54 198,000 284,000 11.0 54 198,000 284,000 11.0 54 198,000 203,000 11.0 54 198,000 203,000 11.0 54 198,000 203,000 11.0 54 198,000 284,000 11.0 54 198,000 284,000 11.0 54 198,000 284,000 11.0 54
86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86
123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123
CK/001 2540 CK/001 2560 CK/001 2541 CK/001 2540 CK/001 2560 CK/001 2541 CK/001 2540 CK/001 2560 CK/001 2541 CK/001 2540 CK/001 2560 CK/001 2541 CK/001 2540 CK/001 2560 CK/001 2541 CK/001 2540 CK/001 2560 CK/001 2541
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Liquid line drier Operating charge of R-410A Short orifice refrigerant control Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Trane 3-D scroll compressors Dedicated horizontal and downflow designs Single side access Drum and tube gas heat exchanger Hot surface ignition system Aluminized steel drum material Forced combustion Gas burner view port Negative pressure gas valve Quick-access panels with handles Sloped sheet metal drain pan Internally enhanced coil tubing Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 5 year compressor and heat exchanger warranty on 17-1/2 ton units Optional extended warranties
PG 61
17-1/2Ton YCD210E
Specifications: Downflow
Model Number YCD210E3L0A YCD210E3LAA YCD210E3LBA YCD210E3LCA YCD210E3LFA YCD210E3LGA YCD210E3H0A YCD210E3HAA YCD210E3HBA YCD210E3HCA YCD210E3HFA YCD210E3HGA YCD210E4L0A YCD210E4LAA YCD210E4LBA YCD210E4LCA YCD210E4LFA YCD210E4LGA YCD210E4H0A YCD210E4HAA YCD210E4HBA YCD210E4HCA YCD210E4HFA YCD210E4HGA YCD210EWL0A YCD210EWLAA YCD210EWLBA YCD210EWLCA YCD210EWLFA YCD210EWLGA YCD210EWH0A YCD210EWHAA YCD210EWHBA YCD210EWHCA YCD210EWHFA YCD210EWHGA Factory Installed Option Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Power Supply 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 Capacity Cooling (BTUH) 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 198,000 Capacity Heating Output (BTUH) EER 203,000 11.0 203,000 11.0 203,000 11.0 203,000 11.0 203,000 11.0 203,000 11.0 284,000 284,000 284,000 284,000 284,000 284,000 203,000 203,000 203,000 203,000 203,000 203,000 284,000 284,000 284,000 284,000 284,000 284,000 203,000 203,000 203,000 203,000 203,000 203,000 284,000 284,000 284,000 284,000 284,000 284,000 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 Uncrated Dimensions (in.) H W L 54 86 123 54 86 123 54 86 123 54 86 123 54 86 123 54 86 123 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123
Mfg. Shipping Plant Weight CK/001 2540 CK/001 2630 CK/001 2580 CK/001 2670 CK/001 2541 CK/001 2631 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 2540 2630 2580 2670 2541 2631 2540 2630 2580 2670 2541 2631 2540 2630 2580 2670 2541 2631 2540 2630 2580 2670 2541 2631 2540 2630 2580 2670 2541 2631
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Short orifice refrigerant control Liquid line drier Operating charge of R-410A Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Trane 3-D scroll compressors Dedicated downflow design Single side access Drum and tube gas heat exchanger Hot surface ignition system Aluminized steel drum material Forced combustion Gas burner view port Negative pressure gas valve Sloped sheet metal drain pan Quick-access panels with handles Internally enhanced coil tubing Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 5 year compressor and heat exchanger warranty
PG 62
Description ReliaTelTM Options Module Downflow Roof Curb 0-25% Manual Outside Air Damper Motorized Outside Air Damper Downflow Economizer with Barometric Relief Horizontal Economizer Tool-less Condenser Coil Hail Guard Remote Potentiometer Power Exhaust for use with Downflow Economizer 230V Power Exhaust for use with Downflow Economizer 460V Power Exhaust for use with Downflow Economizer/575V 7 HP Oversize Motor Kit 7 HP Oversize Motor Kit 7 HP Oversize Motor Kit/575V Low Static Drive LP Conversion Kit Selective Resistance Service Tester Temperature Sensor High Temperature Stat Reference Enthalpy Kit Comparative Enthalpy Kit Clogged Filter Switch Fan Failure Switch
Evaporator Defrost Control (Frostat)
BAYTUBE008A5 BAYTUBE009A5
BAYVNOR002B
CK/001 CK/001
1 1
2
1 For downflow use only. Cannot be adapted for horizontal units. 2 Kits contain all necessary parts to achieve desired level of enthalpy control. 3 Must be used with either field or factory installed TCI (Trane Communication Interface). 4 Low static drive and oversized motors are mutually exclusive. Do not combine. 5 Used for true discharge air sensing in both heating and cooling models. Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B). 6 Clarksville Manufacturing has a no-return policy for this roof curb. 7 BAYABRD002B is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS005A), Fan Fail Switch (BAYDFPS006A), Discharge Air Sensing Kit (BAYTUBE008A or BAYTUBE009A), Frostat (BAYLOAM023A), Ventilation Override (BAYVNOR002B). 8 Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B).
PG 63
20 Ton YCH240E
Specifications: Horizontal
Factory Model Installed Number Option YCH240E3L0A YCH240E3LBA Ov Motor YCH240E3LFA TCI Capacity Power Cooling Supply (BTUH) 208-230/3/60 240,000 208-230/3/60 240,000 208-230/3/60 240,000 Capacity Heating Output (BTUH) 203,000 203,000 203,000 Uncrated Dimensions (in.) H W L 54 86 123 54 86 123 54 86 123 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123
Mfg. Shipping Plant Weight CK/001 2600 CK/001 2640 CK/001 2641 CK/001 2600 CK/001 2640 CK/001 2641 CK/001 2600 CK/001 2640 CK/001 2641 CK/001 2600 CK/001 2640 CK/001 2641 CK/001 2600 CK/001 2640 CK/001 2641 CK/001 2600 CK/001 2640 CK/001 2641
YCH240E3H0A 208-230/3/60 240,000 YCH240E3HBA Ov Motor 208-230/3/60 240,000 YCH240E3HFA TCI 208-230/3/60 240,000 YCH240E4L0A 460/3/60 YCH240E4LBA Ov Motor 460/3/60 YCH240E4LFA TCI 460/3/60 YCH240E4H0A 460/3/60 YCH240E4HBA Ov Motor 460/3/60 YCH240E4HFA TCI 460/3/60 YCH240EWL0A 575/3/60 YCH240EWLBA Ov Motor 575/3/60 YCH240EWLFA TCI 575/3/60 YCH240EWH0A 575/3/60 YCH240EWHBA Ov Motor 575/3/60 YCH240EWHFA TCI 575/3/60 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000
324,000 10.2 54 324,000 10.2 54 324,000 10.2 54 203,000 10.2 54 203,000 10.2 54 203,000 10.2 54 324,000 10.2 54 324,000 10.2 54 324,000 10.2 54 203,000 10.2 54 203,000 10.2 54 203,000 10.2 54 324,000 10.2 54 324,000 10.2 54 324,000 10.2 54
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Liquid line drier Operating charge of R-410A Short orifice refrigerant control Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Trane 3-D scroll compressors Dedicated horizontal and downflow designs Single side access Drum and tube gas heat exchanger Hot surface ignition system Aluminized steel drum material Forced combustion Gas burner view port Negative pressure gas valve Sloped sheet metal drain pan Quick-access panels with handles Internally enhanced coil tubing Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 1 year compressor and heat exchanger warranty
PG 64
20 Ton YCD240E
Specifications: Downflow
Model Number
YCD240E3L0A YCD240E3LAA YCD240E3LBA YCD240E3LCA YCD240E3LFA YCD240E3LGA YCD240E3H0A YCD240E3HAA YCD240E3HBA YCD240E3HCA YCD240E3HFA YCD240E3HGA YCD240E4L0A YCD240E4LAA YCD240E4LBA YCD240E4LCA YCD240E4LFA YCD240E4LGA YCD240E4H0A YCD240E4HAA YCD240E4HBA YCD240E4HCA YCD240E4HFA YCD240E4HGA YCD240EWL0A YCD240EWLAA YCD240EWLBA YCD240EWLCA YCD240EWLFA YCD240EWLGA YCD240EWH0A YCD240EWHAA YCD240EWHBA YCD240EWHCA YCD240EWHFA YCD240EWHGA
Power Supply
208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60
Capacity Capacity Heating Uncrated Cooling Output Dimensions (in.) Mfg. Shipping (BTUH) (BTUH) EER H W L Plant Weight
240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 240,000 203,000 203,000 203,000 203,000 203,000 203,000 324,000 324,000 324,000 324,000 324,000 324,000 203,000 203,000 203,000 203,000 203,000 203,000 324,000 324,000 324,000 324,000 324,000 324,000 203,000 203,000 203,000 203,000 203,000 203,000 324,000 324,000 324,000 324,000 324,000 324,000 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 10.2 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 2640 2730 2680 2770 2641 2731 2640 2730 2680 2770 2641 2731 2640 2730 2680 2770 2641 2731 2640 2730 2680 2770 2641 2731 2640 2730 2680 2770 2641 2731 2640 2730 2680 2770 2641 2731
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Short orifice refrigerant control
Liquid line drier Operating charge of R-410A Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Trane 3-D scroll compressors Dedicated downflow design Single side access Drum and tube gas heat exchanger Hot surface ignition system Aluminized steel drum material
Sloped sheet metal drain pan Forced combustion Gas burner view port Negative pressure gas valve Quick-access panels with handles Internally enhanced coil tubing Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 1 year compressor and heat exchanger warranty
PG 65
12-1/2 25 Ton
Zone Sensors: (Micro Thermostats to be used with Micro Units)
Model Number BAYSENS006B BAYSENS008B BAYSENS010B BAYSENS019C BAYSENS013C1 BAYSENS014C1 BAYSENS017B BAYSENS032A3 BAYSENS035A3 BAYMTPL003B BAYMTPL004B BAYSTAT050A BAYSTAT052A BAYSTAT053A Description Single Setpoint Manual Changeover Dual Setpoint Manual or Auto Changeover Dual Setpoint Man. or Auto Changeover with System Function Lights Programmable Night Setback w/System Function Lights Room Sensor w/ Override Button Room Sensor w/ Temp. Adjustment And Override Remote Room Sensor Dual Thermistor Remote Zone Sensor Digital Display Zone Sensor Retrofit Wall Cover Plate Kit 7.25" x 6.0" Retrofit Wall Cover Plate Kit 4.75" x 4.75" 2Htg/2Clg Digital Display Programmable Thermostat 2Htg/2Clg Digital Display Programmable "TOUCHSCREEN" Thermostat 3Htg/2Clg Digital Display Programmable Thermostat with Relative Humidity Sensing Built-In 3Htg/2Clg Digital Display Thermostat Return Air Remote Sensor Wall Mounted Remote Sensor
TM
Packaged Gas/Electric
Mfg. Shipping Plant Weight CK/001 1 CK/001 1 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 1 1 1 1 1 1 1 1 1 1 1 1
Used with YC*150-300 YC*150-300 YC*150-300 YC*150-300 YC*150-300 YC*150-300 BAYSENS006B, 008B, 010B & 019C YC*150-300 YC*150-300 BAYSENS019C BAYSENS006,008,010 017B,013,& 014C YC*150-300 YC*150-300
YC*150-300 CK/001 (with Dehumidification Option) YC*150-300 CK/001 BAYSTAT050A,052A,053A CK/001 BAYSTAT050A,052A,053A CK/001
1 Used with Integrated Comfort Systems, any unit type. These sensors do not work with TCM. Consult BASD Marketing for them. 2 See Accessory IOM for operational characteristics. 3 Functional only with ReliaTel controls.
* Either horizontal or downflow models.
1 1 1
Controls:
Model Number BAYCO2K002B BAYCO2K004B BAYICSI004B BAYLTCI003B Description CO2 Sensor Kit Wall Mounted CO2 Sensor Kit Duct Mounted Field Installed TCI (Trane Communication Interface) LonTalk Interface Used with YC*150-300 w/Economizer YC*150-300 w/Economizer YC*150-300 YC*150-300 Mfg. Shipping Plant Weight CK/001 3 CK/001 CK/001 CK/001 3.5 1 1
PG 66
Uncrated Dimensions (in.) H W L 50 72 108 50 72 108 50 72 108 50 72 50 72 50 72 50 72 50 72 50 72 50 72 50 72 50 72 50 72 50 72 50 72 50 72 50 72 50 72 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108
Mfg. Shipping Plant Weight CK/001 1915 CK/001 1990 CK/001 1916 CK/001 1915 CK/001 1990 CK/001 1916 CK/001 1915 CK/001 1990 CK/001 1916 CK/001 1915 CK/001 1990 CK/001 1916 CK/001 1915 CK/001 1990 CK/001 1916 CK/001 1915 CK/001 1990 CK/001 1916
208-230/3/60 154,000 203,000 11.30 208-230/3/60 154,000 203,000 11.30 208-230/3/60 154,000 203,000 11.30 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 154,000 122,000 11.30 154,000 122,000 11.30 154,000 122,000 11.30 154,000 203,000 11.30 154,000 203,000 11.30 154,000 203,000 11.30 154,000 122,000 11.30 154,000 122,000 11.30 154,000 122,000 11.30 154,000 203,000 11.30 154,000 203,000 11.30 154,000 203,000 11.30
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Liquid line drier Operating charge of R-22 Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Short orifice refrigerant control High efficiency scroll compressors Low pressure switches Dedicated horizontal and downflow designs Single side access Drum and tube gas heat exchanger Hot surface ignition system Aluminized steel drum material Forced combustion Gas burner view port Sloped sheet metal drain pan Negative pressure gas valve Quick-access panels with handles Internally enhanced coil tubing Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 5 year compressor and heat exchanger warranty
PG 67
Capacity Heating Uncrated Output Dimensions (in.) (BTUH) EER H W L 122,000 11.30 50 72 108 122,000 11.30 50 72 108 122,000 11.30 50 72 108 122,000 11.30 50 72 108 122,000 11.30 50 72 108 122,000 11.30 50 72 108 122,000 122,000 122,000 122,000 11.30 11.30 11.30 11.30 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 55 55 55 55 55 55 55 55 55 55 55 55 55 55 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 108 108 108 108
Mfg. Shipping Plant Weight CK/001 1915 CK/001 2030 CK/001 1990 CK/001 2105 CK/001 1916 CK/001 2031 CK/001 CK/001 CK/001 CK/001 1915 1990 2105 2030
YFD151C3LMB Reheat Coil YFD151C3LNB Econ/Reheat Coil YFD151C3LPB Ov Mtr/Reheat Coil YFD151C3LRB Econ/Ov Mtr/Reheat Coil YCD151C3H0B YCD151C3HAB YCD151C3HBB YCD151C3HCB YCD151C3HFB YCD151C3HGB YCD151C3HHB YCD151C3HJB YCD151C3HKB YCD151C3HLB Economizer Ov Motor Econ/OvMtr TCI Econ/TCI TXV TXV/OvMtr TXV/OvMtr/Econ TXV/Econ
208-230/3/60 154,000 122,000 11.30 208-230/3/60 154,000 122,000 11.30 208-230/3/60 154,000 122,000 11.30 208-230/3/60 154,000 122,000 11.30 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 154,000 154,000 154,000 154,000 154,000 154,000 154,000 154,000 154,000 154,000 203,000 203,000 203,000 203,000 203,000 203,000 203,000 203,000 203,000 203,000 11.30 11.30 11.30 11.30 11.30 11.30 11.30 11.30 11.30 11.30
108 CK/001 2070 108 CK/001 2185 108 CK/001 2145 108 CK/001 2260 108 108 108 108 108 108 108 108 108 108 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 1915 2030 1990 2105 1916 2031 1915 1990 2105 2030
YFD151C3HMB Reheat Coil YFD151C3HNB Econ/Reheat Coil YFD151C3HPB Ov Mtr/Reheat Coil YFD151C3HRB Econ/Ov Mtr/Reheat Coil YCD151C4L0B YCD151C4LAB YCD151C4LBB YCD151C4LCB YCD151C4LFB YCD151C4LGB YCD151C4LHB YCD151C4LJB YCD151C4LKB YCD151C4LLB Economizer Ov Motor Econ/OvMtr TCI Econ/TCI TXV TXV/OvMtr TXV/OvMtr/Econ TXV/Econ
208-230/3/60 154,000 203,000 11.30 208-230/3/60 154,000 203,000 11.30 208-230/3/60 154,000 203,000 11.30 208-230/3/60 154,000 203,000 11.30 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 154,000 154,000 154,000 154,000 154,000 154,000 154,000 154,000 154,000 154,000 122,000 122,000 122,000 122,000 122,000 122,000 122,000 122,000 122,000 122,000 11.30 11.30 11.30 11.30 11.30 11.30 11.30 11.30 11.30 11.30
108 CK/001 2070 108 CK/001 2185 108 CK/001 2145 108 CK/001 2260 108 108 108 108 108 108 108 108 108 108 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 1915 2030 1990 2105 1916 2031 1915 1990 2105 2030
YFD151C4LMB Reheat Coil YFD151C4LNB Econ/Reheat Coil YFD151C4LPB Ov Mtr/Reheat Coil YFD151C4LRB Econ/Ov Mtr/Reheat Coil
154,000 122,000 11.30 154,000 122,000 11.30 154,000 122,000 11.30 154,000 122,000 11.30 PG 68
108 CK/001 2070 108 CK/001 2185 108 CK/001 2145 108 CK/001 2260 Effective date: January 1, 2007
Uncrated Dimensions (in.) EER H W L 11.30 55 72 108 11.30 55 72 108 11.30 55 72 108 11.30 55 72 108 11.30 55 72 108 11.30 55 72 108 11.30 11.30 11.30 11.30 55 55 55 55 55 55 55 55 50 50 50 50 50 50 50 50 50 50 50 50 50 50 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 108 108 108 108
Mfg. Shipping Plant Weight CK/001 1915 CK/001 2030 CK/001 1990 CK/001 2105 CK/001 1916 CK/001 2031 CK/001 CK/001 CK/001 CK/001 1915 1990 2105 2030
YFD151C4HMB Reheat Coil YFD151C4HNB Econ/Reheat Coil YFD151C4HPB Ov Mtr/Reheat Coil YFD151C4HRB Econ/Ov Mtr/Reheat Coil YCD151CWL0B YCD151CWLAB YCD151CWLBB YCD151CWLCB YCD151CWLFB YCD151CWLGB YCD151CWLHB YCD151CWLJB YCD151CWLKB YCD151CWLLB Economizer Ov Motor Econ/OvMtr TCI Econ/TCI TXV TXV/OvMtr TXV/OvMtr/Econ TXV/Econ
154,000 122,000 11.30 154,000 122,000 11.30 154,000 122,000 11.30 154,000 122,000 11.30 154,000 154,000 154,000 154,000 154,000 154,000 154,000 154,000 154,000 154,000 122,000 122,000 122,000 122,000 122,000 122,000 122,000 122,000 122,000 122,000 11.30 11.30 11.30 11.30 11.30 11.30 11.30 11.30 11.30 11.30
108 CK/001 2070 108 CK/001 2185 108 CK/001 2145 108 CK/001 2260 108 108 108 108 108 108 108 108 108 108 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 1915 2030 1990 2105 1916 2031 1915 1990 2105 2030
YFD151CWLMB Reheat Coil YFD151CWLNB Econ/Reheat Coil YFD151CWLPB Ov Mtr/Reheat Coil YFD151CWLRB Econ/Ov Mtr/Reheat Coil
154,000 122,000 11.30 154,000 122,000 11.30 154,000 122,000 11.30 154,000 122,000 11.30
108 CK/001 2070 108 CK/001 2185 108 CK/001 2145 108 CK/001 2260
PG 69
Capacity Heating Uncrated Output Dimensions (in.) (BTUH) EER H W L 203,000 11.30 50 72 108 203,000 11.30 50 72 108 203,000 11.30 50 72 108 203,000 11.30 50 72 108 203,000 11.30 50 72 108 203,000 11.30 50 72 108 203,000 203,000 203,000 203,000 11.30 11.30 11.30 11.30 50 50 50 50 50 50 50 50 72 72 72 72 72 72 72 72 108 108 108 108
Mfg. Shipping Plant Weight CK/001 1915 CK/001 2030 CK/001 1990 CK/001 2105 CK/001 1916 CK/001 2031 CK/001 CK/001 CK/001 CK/001 1915 1990 2105 2030
YFD151CWHMB Reheat Coil YFD151CWHNB Econ/Reheat Coil YFD151CWHPB Ov Mtr/Reheat Coil YFD151CWHRB Econ/Ov Mtr/Reheat Coil
154,000 203,000 11.30 154,000 203,000 11.30 154,000 203,000 11.30 154,000 203,000 11.30
108 CK/001 2070 108 CK/001 2185 108 CK/001 2145 108 CK/001 2260
Features
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Short orifice refrigerant control
Liquid line drier Operating charge of R-22 Trane-Tite-Top (T3) weather tight top and cabinet High efficiency scroll compressors Low pressure switches Dedicated horizontal and downflow designs Single side access Drum and tube heat exchanger Hot surface ignition system
Aluminized steel drum material Forced combustion Gas burner view port Negative pressure gas valve Sloped sheet metal drain pan Internally enhanced coil tubing Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 5 year compressor warranty
PG 70
Shipping Weight
2 205 32 60 115 150 50 1 95 95 95 75 75 15 1 2 1 1 1 1 1 1 3 1 1 2
See Note 8 YCD151C YCD151C YCH151C YCD151C YCH151C YCD151C YCH151C YC*151C BAYECON089A,091A BAYDMPR057A YCD151C3 YCD151C4 YCD151CW
1 For downflow use only. Cannot be adapted for horizontal units. 2 Kits contain all necessary parts to achieve desired level of enthalpy control. 3 Must be used with either field or factory installed TCI (Trane Communication Interface). 4 High static drive and oversized motors are mutually exclusive. Do not combine. 5 Used for true discharge air sensing in both heating and cooling models. Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B). 6 Cannot be used with manual outside air damper. 7 Clarksville Manufacturing has a no-return policy for this roof curb. 8 BAYABRD002B is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS005A), Fan Fail Switch (BAYDFPS006A), Discharge Air Sensing Kit (BAYTUBE008A or BAYTUBE009A), Frostat (BAYLOAM023A), Ventilation Override (BAYVNOR002B). 9 Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B).
PG 71 Effective date: January 1, 2007
YCD151C3,C4 YCH151C3,C4 YCD151CW YCH151CW YCD151C YCH151C YCD151C YCH151C YCD151C YCH151C YCD151C YCH151C YCD151C YCH151C BAYECON089A BAYECON091A BAYECON089A BAYECON091A YCD151C YCH151C YCD151C YCH151C YC*151C w/ReliaTel Options Module YCD151C YCH151C YC*151C w/ReliaTel Options Module
15 Ton YCH181C
High Efficiency Specifications: Horizontal
Factory Model Installed Number Option YCH181C3L0C YCH181C3LBC Ov Motor YCH181C3LFC TCI Gross Capacity Capacity Heating Power Cooling Output Supply (BTUH) (BTUH) 208-230/3/60 189,000 203,000 208-230/3/60 189,000 203,000 208-230/3/60 189,000 203,000
EER 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50
Uncrated Dimensions (in.) H W L 54 86 123 54 86 123 54 86 123 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123
Mfg. Shipping Plant Weight CK/001 2476 CK/001 2566 CK/001 2477 CK/001 2476 CK/001 2566 CK/001 2477 CK/001 2476 CK/001 2566 CK/001 2477 CK/001 2476 CK/001 2566 CK/001 2477 CK/001 2476 CK/001 2566 CK/001 2477 CK/001 2476 CK/001 2566 CK/001 2477
YCH181C3H0C 208-230/3/60 189,000 284,000 YCH181C3HBC Ov Motor 208-230/3/60 189,000 284,000 YCH181C3HFC TCI 208-230/3/60 189,000 284,000 YCH181C4L0C 460/3/60 YCH181C4LBC Ov Motor 460/3/60 YCH181C4LFC TCI 460/3/60 YCH181C4H0C 460/3/60 YCH181C4HBC Ov Motor 460/3/60 YCH181C4HFC TCI 460/3/60 YCH181CWL0C 575/3/60 YCH181CWLBC Ov Motor 575/3/60 YCH181CWLFC TCI 575/3/60 YCH181CWH0C 575/3/60 YCH181CWHBC Ov Motor 575/3/60 YCH181CWHFC TCI 575/3/60 189,000 203,000 189,000 203,000 189,000 203,000 189,000 284,000 189,000 284,000 189,000 284,000 189,000 203,000 189,000 203,000 189,000 203,000 189,000 284,000 189,000 284,000 189,000 284,000
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Short orifice refrigerant control Liquid line drier Operating charge of R-22 Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Trane 3-D scroll compressors Low pressure switches Dedicated horizontal and downflow designs Single side access Drum and tube heat exchanger Hot surface ignition system Aluminized steel drum material Forced combustion Sloped sheet metal drain pan Gas burner view port Negative pressure gas valve Quick-access panels with handles Internally enhanced coil tubing Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 5 year compressor and heat exchanger warranty
PG 72
Uncrated Dimensions (in.) EER H W L 11.50 54 86 123 11.50 54 86 123 11.50 54 86 123 11.50 54 86 123 11.50 54 86 123 11.50 54 86 123 11.50 11.50 11.50 11.50 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 123 123 123 123
Mfg. Shipping Plant Weight CK/001 2460 CK/001 2595 CK/001 2550 CK/001 2685 CK/001 2461 CK/001 2596 CK/001 CK/001 CK/001 CK/001 2460 2550 2685 2595
YFD181C3LMC Reheat Coil YFD181C3LNC Econ/Reheat Coil YFD181C3LPC Ov Mtr/Reheat Coil YFD181C3LRC Econ/Ov Mtr/Reheat Coil YCD181C3H0C YCD181C3HAC YCD181C3HBC YCD181C3HCC YCD181C3HFC YCD181C3HGC YCD181C3HHC YCD181C3HJC YCD181C3HKC YCD181C3HLC Economizer Ov Motor Econ/OvMtr TCI Econ/TCI TXV TXV/OvMtr TXV/OvMtr/Econ TXV/Econ
208-230/3/60 189,000 203,000 11.50 208-230/3/60 189,000 203,000 11.50 208-230/3/60 189,000 203,000 11.50 208-230/3/60 189,000 203,000 11.50 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 189,000 189,000 189,000 189,000 189,000 189,000 189,000 189,000 189,000 189,000 284,000 284,000 284,000 284,000 284,000 284,000 284,000 284,000 284,000 284,000 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50
123 CK/001 2615 123 CK/001 2750 123 CK/001 2705 123 CK/001 2840 123 123 123 123 123 123 123 123 123 123 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 2460 2595 2550 2685 2461 2596 2460 2550 2685 2595
YFD181C3HMC Reheat Coil YFD181C3HNC Econ/Reheat Coil YFD181C3HPC Ov Mtr/Reheat Coil YFD181C3HRC Econ/Ov Mtr/Reheat Coil YCD181C4L0C YCD181C4LAC YCD181C4LBC YCD181C4LCC YCD181C4LFC YCD181C4LGC YCD181C4LHC YCD181C4LJC YCD181C4LKC YCD181C4LLC Economizer Ov Motor Econ/OvMtr TCI Econ/TCI TXV TXV/OvMtr TXV/OvMtr/Econ TXV/Econ
208-230/3/60 189,000 284,000 11.50 208-230/3/60 189,000 284,000 11.50 208-230/3/60 189,000 284,000 11.50 208-230/3/60 189,000 284,000 11.50 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 189,000 189,000 189,000 189,000 189,000 189,000 189,000 189,000 189,000 189,000 203,000 203,000 203,000 203,000 203,000 203,000 203,000 203,000 203,000 203,000 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50
123 CK/001 2615 123 CK/001 2750 123 CK/001 2705 123 CK/001 2805 123 123 123 123 123 123 123 123 123 123 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 2460 2595 2550 2685 2461 2596 2460 2550 2685 2595
YFD181C4LMC Reheat Coil YFD181C4LNC Econ/Reheat Coil YFD181C4LPC Ov Mtr/Reheat Coil YFD181C4LRC Econ/Ov Mtr/Reheat Coil
189,000 203,000 11.50 189,000 203,000 11.50 189,000 203,000 11.50 189,000 203,000 11.50 PG 73
123 CK/001 2615 123 CK/001 2750 123 CK/001 2705 123 CK/001 2840 Effective date: January 1, 2007
Capacity Heating Uncrated Output Dimensions (in.) (BTUH) EER H W L 284,000 11.50 54 86 123 284,000 11.50 54 86 123 284,000 11.50 54 86 123 284,000 11.50 54 86 123 284,000 11.50 54 86 123 284,000 11.50 54 86 123 284,000 284,000 284,000 284,000 11.50 11.50 11.50 11.50 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 123 123 123 123
Mfg. Shipping Plant Weight CK/001 2460 CK/001 2595 CK/001 2550 CK/001 2685 CK/001 2461 CK/001 2596 CK/001 CK/001 CK/001 CK/001 2460 2550 2685 2595
YFD181C4HMC Reheat Coil YFD181C4HNC Econ/Reheat Coil YFD181C4HPC Ov Mtr/Reheat Coil YFD181C4HRC Econ/Ov Mtr/Reheat Coil YCD181CWL0C YCD181CWLAC YCD181CWLBC YCD181CWLCC YCD181CWLFC YCD181CWLGC YCD181CWLHC YCD181CWLJC YCD181CWLKC YCD181CWLLC Economizer Ov Motor Econ/OvMtr TCI Econ/TCI TXV TXV/OvMtr TXV/OvMtr/Econ TXV/Econ
189,000 284,000 11.50 189,000 284,000 11.50 189,000 284,000 11.50 189,000 284,000 11.50 189,000 189,000 189,000 189,000 189,000 189,000 189,000 189,000 189,000 189,000 203,000 203,000 203,000 203,000 203,000 203,000 203,000 203,000 203,000 203,000 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50
123 CK/001 2615 123 CK/001 2750 123 CK/001 2705 123 CK/001 2840 123 123 123 123 123 123 123 123 123 123 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 2460 2595 2550 2685 2461 2596 2460 2550 2685 2595 2615 2750 2705 2840
YFD181CWLMC Reheat Coil YFD181CWLNC Econ/Reheat Coil YFD181CWLPC Ov Mtr/Reheat Coil YFD181CWLRC Econ/Ov Mtr/Reheat Coil
189,000 203,000 11.50 189,000 203,000 11.50 189,000 203,000 11.50 189,000 203,000 11.50
PG 74
Uncrated Dimensions (in.) EER H W L 11.50 54 86 123 11.50 54 86 123 11.50 54 86 123 11.50 54 86 123 11.50 54 86 123 11.50 54 86 123 11.50 11.50 11.50 11.50 54 54 54 54 54 54 54 54 86 86 86 86 86 86 86 86 123 123 123 123
Mfg. Shipping Plant Weight CK/001 2460 CK/001 2595 CK/001 2550 CK/001 2685 CK/001 2461 CK/001 2596 CK/001 CK/001 CK/001 CK/001 2460 2550 2685 2595 2615 2750 2705 2840
YFD181CWHMC Reheat Coil YFD181CWHNC Econ/Reheat Coil YFD181CWHPC Ov Mtr/Reheat Coil YFD181CWHRC Econ/Ov Mtr/Reheat Coil
189,000 203,000 11.50 189,000 203,000 11.50 189,000 203,000 11.50 189,000 203,000 11.50
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Short orifice refrigerant control Liquid line drier Operating charge of R-22 Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Trane 3-D scroll compressors Low pressure switches Dedicated horizontal and downflow designs Single side access Drum and tube heat exchanger Hot surface ignition system Aluminized steel drum material Forced combustion Sloped sheet metal drain pan Gas burner view port Negative pressure gas valve Quick-access panels with handles Internally enhanced coil tubing Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 5 year compressor and heat exchanger warranty
PG 75
EER 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0
Uncrated Dimensions (in.) H W L 54 86 123 54 86 123 54 86 123 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123
Mfg. Shipping Plant Weight CK/001 2531 CK/001 2621 CK/001 2532 CK/001 2531 CK/001 2621 CK/001 2532 CK/001 2531 CK/001 2621 CK/001 2532 CK/001 2531 CK/001 2621 CK/001 2532 CK/001 2531 CK/001 2621 CK/001 2532 CK/001 2531 CK/001 2621 CK/001 2532
YCH211C3H0C 208-230/3/60 220,000 284,000 YCH211C3HBC Ov Motor 208-230/3/60 220,000 284,000 YCH211C3HFC TCI 208-230/3/60 220,000 284,000 YCH211C4L0C 460/3/60 YCH211C4LBC Ov Motor 460/3/60 YCH211C4LFC TCI 460/3/60 YCH211C4H0C 460/3/60 YCH211C4HBC Ov Motor 460/3/60 YCH211C4HFC TCI 460/3/60 YCH211CWL0C 575/3/60 YCH211CWLBC Ov Motor 575/3/60 YCH211CWLFC TCI 575/3/60 YCH211CWH0C 575/3/60 YCH211CWHBC Ov Motor 575/3/60 YCH211CWHFC TCI 575/3/60 220,000 203,000 220,000 203,000 220,000 203,000 220,000 284,000 220,000 284,000 220,000 284,000 220,000 203,000 220,000 203,000 220,000 203,000 220,000 284,000 220,000 284,000 220,000 284,000
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Short orifice refrigerant control Liquid line drier Operating charge of R-22 Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Trane 3-D scroll scroll compressors Low pressure switches Dedicated horizontal and downflow designs Single side access Drum and tube heat exchanger Hot surface ignition system Aluminized steel drum material Forced combustion Sloped sheet metal drain pan Gas burner view port Negative pressure gas valve Quick-access panels with handles Internally enhanced coil tubing Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 5 year compressor and heat exchanger warranty
PG 76
Uncrated Dimensions (in.) H W L 54 86 123 54 86 123 54 86 123 54 86 123 54 86 123 54 86 123 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123
Mfg. Shipping Plant Weight CK/001 2531 CK/001 2666 CK/001 2621 CK/001 2756 CK/001 2532 CK/001 2667 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 2531 2666 2621 2756 2531 2666 2621 2756 2532 2667 2531 2666 2621 2756 2531 2666 2621 2756 2532 2667 2531 2666 2621 2756 2531 2666 2621 2756 2532 2667 2531 2666 2621 2756
TXV 208-230/3/60 TXV/OvMtr 208-230/3/60 TXV/OvMtr/Econ 208-230/3/60 TXV/Econ 208-230/3/60 Economizer Ov Motor Econ/OvMtr TCI Econ/TCI 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60
TXV 208-230/3/60 TXV/OvMtr 208-230/3/60 TXV/OvMtr/Econ 208-230/3/60 TXV/Econ 208-230/3/60 Economizer Ov Motor Econ/OvMtr TCI Econ/TCI 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60
TXV 460/3/60 TXV/OvMtr 460/3/60 TXV/OvMtr/Econ 460/3/60 TXV/Econ 460/3/60 Economizer Ov Motor Econ/OvMtr TCI Econ/TCI 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60
PG 77
Uncrated Dimensions (in.) H W L 54 86 123 54 86 123 54 86 123 54 86 123 54 86 123 54 86 123 54 54 54 54 54 54 54 54 54 54 54 54 54 54 86 86 86 86 86 86 86 86 86 86 86 86 86 86 123 123 123 123 123 123 123 123 123 123 123 123 123 123
Mfg. Shipping Plant Weight CK/001 2531 CK/001 2666 CK/001 2621 CK/001 2756 CK/001 2532 CK/001 2667 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 2531 2666 2621 2756 2531 2666 2621 2756 2532 2667 2531 2666 2621 2756
TXV 575/3/60 TXV/OvMtr 575/3/60 TXV/OvMtr/Econ 575/3/60 TXV/Econ 575/3/60 Economizer Ov Motor Econ/OvMtr TCI Econ/TCI 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60
PG 78
20 Ton YCH241C
High Efficiency Specifications: Horizontal
Factory Model Installed Number Option YCH241C3L0C YCH241C3LBC Ov Motor YCH241C3LFC TCI YCH241C3H0C YCH241C3HBC Ov Motor YCH241C3HFC TCI YCH241C4L0C YCH241C4LBC Ov Motor YCH241C4LFC TCI YCH241C4H0C YCH241C4HBC Ov Motor YCH241C4HFC TCI YCH241CWL0C YCH241CWLBC Ov Motor YCH241CWLFC TCI YCH241CWH0C YCH241CWHBC Ov Motor YCH241CWHFC TCI Gross Capacity Power Cooling Supply (BTUH) 208-230/3/60 268,000 208-230/3/60 268,000 208-230/3/60 268,000 Capacity Heating Output (BTUH) EER 203,000 10.60 203,000 10.60 203,000 10.60
Uncrated Dimensions (in.) H W L 54 86 123 54 86 123 54 86 123 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123
Mfg. Shipping Plant Weight CK/001 2645 CK/001 2735 CK/001 2646 CK/001 2645 CK/001 2735 CK/001 2646 CK/001 2645 CK/001 2735 CK/001 2646 CK/001 2645 CK/001 2735 CK/001 2646 CK/001 2645 CK/001 2735 CK/001 2646 CK/001 2645 CK/001 2735 CK/001 2646
208-230/3/60 268,000 284,000 10.60 208-230/3/60 268,000 284,000 10.60 208-230/3/60 268,000 284,000 10.60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 268,000 203,000 10.60 268,000 203,000 10.60 268,000 203,000 10.60 268,000 284,000 10.60 268,000 284,000 10.60 268,000 284,000 10.60 268,000 203,000 10.60 268,000 203,000 10.60 268,000 203,000 10.60 268,000 284,000 10.60 268,000 284,000 10.60 268,000 284,000 10.60
Features:
ReliaTel controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field installed Trane Communications Interface (TCI) Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Liquid line drier Operating charge of R-22 Short orifice refrigerant control Fork lift channels Trane-Tite-Top (T3) weather tight top and cabinet Trane 3-D scroll compressors Low pressure switches Dedicated horizontal and downflow designs Single side access Drum and tube gas heat exchanger Hot surface ignition system Aluminized steel drum material Forced combustion Gas burner view port Negative pressure gas valve Sloped sheet metal drain pan Quick-access panels with handles Internally enhanced coil tubing Low ambient cooling to 0 F standard Colored and numbered wiring UL listed and CSA certified 1 year compressor and heat exchanger warranty on 20 and 25 ton units
PG 79
Capacity Heating Uncrated Output Dimensions (in.) (BTUH) EER H W L 203,000 10.60 54 86 123 203,000 10.60 54 86 123 203,000 10.60 54 86 123 203,000 10.60 54 86 123 203,000 10.60 54 86 123 203,000 10.60 54 86 123 203,000 203,000 203,000 203,000 10.60 10.60 10.60 10.60 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 123 123 123 123
YFD241C3LMC Reheat Coil YFD241C3LNC Econ/Reheat Coil YFD241C3LPC Ov Mtr/Reheat Coil YFD241C3LRC Econ/Ov Mtr/Reheat Coil YCD241C3H0C YCD241C3HAC YCD241C3HBC YCD241C3HCC YCD241C3HFC YCD241C3HGC YCD241C3HHC YCD241C3HJC YCD241C3HKC YCD241C3HLC Economizer Ov Motor Econ/OvMtr TCI Econ/TCI TXV TXV/OvMtr TXV/OvMtr/Econ TXV/Econ
208-230/3/60 268,000 203,000 10.60 208-230/3/60 268,000 203,000 10.60 208-230/3/60 268,000 203,000 10.60 208-230/3/60 268,000 203,000 10.60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 284,000 284,000 284,000 284,000 284,000 284,000 284,000 284,000 284,000 284,000 10.60 10.60 10.60 10.60 10.60 10.60 10.60 10.60 10.60 10.60
123 CK/001 2784 123 CK/001 2919 123 CK/001 2874 123 CK/001 3009 123 123 123 123 123 123 123 123 123 123 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 2629 2764 2719 2854 2630 2765 2629 2719 2854 2764
YFD241C3HMC Reheat Coil YFD241C3HNC Econ/Reheat Coil YFD241C3HPC Ov Mtr/Reheat Coil YFD241C3HRC Econ/Ov Mtr/Reheat Coil YCD241C4L0C YCD241C4LAC YCD241C4LBC YCD241C4LCC YCD241C4LFC YCD241C4LGC YCD241C4LHC YCD241C4LJC YCD241C4LKC YCD241C4LLC Economizer Ov Motor Econ/OvMtr TCI Econ/TCI TXV TXV/OvMtr TXV/OvMtr/Econ TXV/Econ
208-230/3/60 268,000 284,000 10.60 208-230/3/60 268,000 284,000 10.60 208-230/3/60 268,000 284,000 10.60 208-230/3/60 268,000 284,000 10.60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 203,000 203,000 203,000 203,000 203,000 203,000 203,000 203,000 203,000 203,000 10.60 10.60 10.60 10.60 10.60 10.60 10.60 10.60 10.60 10.60
123 CK/001 2784 123 CK/001 2919 123 CK/001 2874 123 CK/001 3009 123 123 123 123 123 123 123 123 123 123 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 2629 2764 2719 2854 2630 2765 2629 2719 2854 2764
YFD241C4LMC Reheat Coil YFD241C4LNC Econ/Reheat Coil YFD241C4LPC Ov Mtr/Reheat Coil YFD241C4LRC Econ/Ov Mtr/Reheat Coil
268,000 203,000 10.60 268,000 203,000 10.60 268,000 203,000 10.60 268,000 203,000 10.60 PG 80
123 CK/001 2784 123 CK/001 2919 123 CK/001 2874 123 CK/001 3009 Effective date: January 1, 2007
YFD241C4HMC Reheat Coil YFD241C4HNC Econ/Reheat Coil YFD241C4HPC Ov Mtr/Reheat Coil YFD241C4HRC Econ/Ov Mtr/Reheat Coil YCD241CWL0C YCD241CWLAC YCD241CWLBC YCD241CWLCC YCD241CWLFC YCD241CWLGC YCD241CWLHC YCD241CWLJC YCD241CWLKC YCD241CWLLC Economizer Ov Motor Econ/OvMtr TCI Econ/TCI TXV TXV/OvMtr TXV/OvMtr/Econ TXV/Econ
268,000 284,000 10.60 268,000 284,000 10.60 268,000 284,000 10.60 268,000 284,000 10.60 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 203,000 203,000 203,000 203,000 203,000 203,000 203,000 203,000 203,000 203,000 10.60 10.60 10.60 10.60 10.60 10.60 10.60 10.60 10.60 10.60
123 CK/001 2784 123 CK/001 2919 123 CK/001 2874 123 CK/001 3009 123 123 123 123 123 123 123 123 123 123 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 2629 2764 2719 2854 2630 2765 2629 2719 2854 2764
YFD241CWLMC Reheat Coil YFD241CWLNC Econ/Reheat Coil YFD241CWLPC Ov Mtr/Reheat Coil YFD241CWLRC Econ/Ov Mtr/Reheat Coil YCD241CWH0C YCD241CWHAC Economizer YCD241CWHBC Ov Motor YCD241CWHCC Econ/OvMtr YCD241CWHFC TCI YCD241CWHGC Econ/TCI YCD241CWHHC TXV YCD241CWHJC TXV/OvMtr YCD241CWHKC TXV/OvMtr/Econ YCD241CWHLC TXV/Econ YFD241CWHMC Reheat Coil YFD241CWHNC Econ/Reheat Coil YFD241CWHPC Ov Mtr/Reheat Coil YFD241CWHRC Econ/Ov Mtr/Reheat Coil
268,000 203,000 10.60 268,000 203,000 10.60 268,000 203,000 10.60 268,000 203,000 10.60 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 268,000 284,000 284,000 284,000 284,000 284,000 284,000 284,000 284,000 284,000 284,000 10.60 10.60 10.60 10.60 10.60 10.60 10.60 10.60 10.60 10.60
123 CK/001 2784 123 CK/001 2919 123 CK/001 2874 123 CK/001 3009 123 123 123 123 123 123 123 123 123 123 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 2629 2764 2719 2854 2630 2765 2629 2719 2854 2764
268,000 284,000 10.60 268,000 284,000 10.60 268,000 284,000 10.60 268,000 284,000 10.60 PG 81
123 CK/001 2784 123 CK/001 2919 123 CK/001 2874 123 CK/001 3009 Effective date: January 1, 2007
203,000 10.40 203,000 10.40 324,000 10.40 324,000 10.40 284,000 10.40 203,000 10.40 324,000 10.40 324,000 10.40
Specifications: Downflow
Model Number
YCD301C3L0C YCD301C3LAC YCD301C3LFC YCD301C3LGC YCD301C3LHC YCD301C3LLC YCD301C3H0C YCD301C3HAC YCD301C3HFC YCD301C3HGC YCD301C3HHC YCD301C3HLC YCD301C4L0C YCD301C4LAC YCD301C4LFC YCD301C4LGC YCD301C4LHC YCD301C4LLC
Power Supply
208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60
Uncrated Dim.(in.) H W L
54 54 54 54 86 86 86 86 123 123 123 123
Mfg. Plant
CK/001 CK/001 CK/001 CK/001
Shipping Weight
2635 2770 2636 2771
TXV TXV/Econ
Economizer TCI Econ/TCI
208-230/3/60 300,000 203,000 10.40 54 86 123 CK/001 208-230/3/60 300,000 203,000 10.40 54 86 123 CK/001
208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 300,000 300,000 300,000 300,000 324,000 324,000 324,000 324,000 10.40 10.40 10.40 10.40 54 54 54 54 86 86 86 86 123 123 123 123 CK/001 CK/001 CK/001 CK/001
2635 2770
2635 2770 2636 2771
TXV TXV/Econ
Economizer TCI Econ/TCI
208-230/3/60 300,000 324,000 10.40 54 86 123 CK/001 208-230/3/60 300,000 324,000 10.40 54 86 123 CK/001
460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 300,000 300,000 300,000 300,000 203,000 203,000 203,000 203,000 10.40 10.40 10.40 10.40 54 54 54 54 86 86 86 86 123 123 123 123 CK/001 CK/001 CK/001 CK/001
2635 2770
2635 2770 2636 2771
TXV TXV/Econ
300,000 203,000 10.40 54 86 123 CK/001 300,000 203,000 10.40 54 86 123 CK/001
2635 2770
PG 82
324,000 10.40 324,000 10.40 284,000 284,000 203,000 203,000 10.40 10.40 10.40 10.40
YCD301CWLHC TXV YCD301CWLLC TXV/Econ YCD301CWH0C YCD301CWHAC YCD301CWHFC YCD301CWHGC Economizer TCI Econ/TCI
203,000 10.40 203,000 10.40 324,000 324,000 324,000 324,000 10.40 10.40 10.40 10.40
PG 83
Shipping Weight
2 235 32 75 135 165 50/60 1 95 95 95 90 110 90 90 90 15 2 2 2 2 1 2 1 1 1 1 1 1 3 1 1 2
1 For downflow use only. Cannot be adapted for horizontal units. 2 Kits contain all necessary parts to achieve desired level of enthalpy control. 3 Must be used with either field or factory installed TCI (Trane Communication Interface). 4 High static drive and oversized motors are mutually exclusive. Do not combine. 5 Used for true discharge air sensing in both heating and cooling models. Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B). 6 Cannot be used with manual outside air damper. 7 Clarksville Manufacturing has a no-return policy for this roof curb. 8 BAYABRD002B is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS005A), Fan Fail Switch (BAYDFPS006A), Discharge Air Sensing Kit (BAYTUBE008A or BAYTUBE009A), Frostat (BAYLOAM023A), Ventilation Override (BAYVNOR002B). 9 Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B).
PG 84 Effective date: January 1, 2007
Extended Warranties (1 yr - 5 yr See Extended Warranty Section) BAYABRD002B ReliaTelTM Options Module See Note 8 BAYCURB027B17 Downflow Roof Curb YCD181-301C BAYDMPR029C 0-25% Manual Outside Air Damper YCD181-301C YCH181-301C BAYDMPR058A Motorized Outside Air Damper YCD181-301C YCH181-301C BAYECON090A Downflow Economizer YCD181-301C with Barometric Relief BAYECON092A Horizontal Economizer YCH181-301C BAYGARD045A Tool-less Condenser Coil Hail Guard YC*181-301C BAYSTAT023 Remote Potentiometer BAYECON090A,091A BAYDMPR058A BAYPWRX029A Power Exhaust for use YCD181-301C3 with Downflow Economizer 230V BAYPWRX030A Power Exhaust for use YCD181-301C4 with Downflow Economizer 460V BAYPWRX031A Power Exhaust for use YCD181-301CW with Downflow Economizer/ 575V BAYHSMT042A4 7 HP Oversize Motor Kit YCD211-241CW/YCH211-241CW BAYHSMT055B4 5 HP Oversize Motor Kit YCD/YCH181C BAYHSMT072A4 7 HP Oversize Motor Kit YCD181CW/YCH181CW BAYHSMT098A4 7 HP Oversize Motor Kit YC*211-241C3 BAYHSMT099A4 7 HP Oversize Motor Kit YC*211-241C4 BAYHSDR004A4 High Static Drive YCD/YCH181C BAYHSDR005B4 High Static Drive YCD211-241C/YCH211-241C BAYHSDR010A4 High Static Drive YCD/YCH301C BAYHSDR011A4 High Static Drive YCD/YCH181 BAYLSDR002A Low Static Drive YCD/YCH301C BAYLPKT018A LP Conversion Kit YCD/H181-301C BAYSERV001A Selective Resistance Service Tester YCD/H181-301C BAYSENS016A6 Temperature Sensor YCD/H181-301C BAYFRST003A3 High Temperature Stat YCD/H181-301C BAYENTH007A2 Reference Enthalpy Kit BAYECON090A BAYECON092A BAYENTH008A2 Comparative Enthalpy Kit BAYECON090A BAYECON092A BAYDFPS005A9 Clogged Filter Switch YCD/H181-301C BAYDFPS006A9 Fan Failure Switch YCD/H181-301C BAYLOAM023A Evaporator Defrost YC*181-301C Control (Frostat) w/ReliaTel Options Module BAYTUBE008A5 Discharge Air Sensing Kit YCD181-301C BAYTUBE009A5 Discharge Air Sensing Kit YCH181-301C BAYVNOR002B Ventilation Override Kit YC*181-301C w/ReliaTel Options Module
12 1/2 25 Ton
High Efficiency Zone Sensors: (Micro Thermostats to be used with ReliaTel Units)
Model Number BAYSENS006B BAYSENS008B BAYSENS010B BAYSENS019C BAYSENS013C1 BAYSENS014C1 BAYSENS017B BAYSENS032A3 BAYSENS035A3 BAYMTPL003B BAYMTPL004B BAYSTAT050A BAYSTAT052A BAYSTAT053A Description Single Setpoint Manual Changeover Dual Setpoint Manual or Auto Changeover Dual Setpoint Man. or Auto Changeover with System Function Lights Programmable Night Setback w/System Function Lights Room Sensor w/Override Button Room Sensor w/ Temp. Adjustment And Override Remote Room Sensor Dual Thermistor Remote Zone Sensor Digital Display Zone Sensor Retrofit Wall Cover Plate Kit 7.25" x 6.0" Retrofit Wall Cover Plate Kit 4.75" x 4.75" 2Htg/2Clg Digital Display Programmable Thermostat 2Htg/2Clg Digital Display Programmable "TOUCHSCREEN" Thermostat 3Htg/2Clg Digital Display Programmable Thermostat with Relative Humidity Sensing Built-In 3Htg/2Clg Digital Display Thermostat Return Air Remote Sensor Wall Mounted Remote Sensor
TM
Packaged Gas/Electric
Used with YC*151-301C YC*151-301C YC*151-301C YC*151-301C YC*151-301C YC*151-301C BAYSENS006B, 008B, 010B & 019C YC*151-301C YC*151-301C BAYSENS019C BAYSENS008,010 017B & 013,014C YC*151-301C YC*151-301C
Mfg. Shipping Plant Weight CK/001 1 CK/001 1 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 1 1 1 1 1 1 1 1 1 1 1 1
YC*151-301C CK/001 (with Dehumidification Option) YC*151-301C CK/001 BAYSTAT050A,052A,053A CK/001 BAYSTAT050A,052A,053A CK/001
1 Used with Integrated Comfort Systems, any unit type. These sensors do not work with TCM. Consult BASD Marketing for them. 2 See Accessory IOM for operational characteristics. 3 Functional only with ReliaTel controls.
* Either horizontal or downflow models.
1 1 1
Controls:
Model Number BAYCO2K002B BAYCO2K004B BAYICSI004B BAYLTCI003B Description CO2 Sensor Kit Wall Mounted CO2 Sensor Kit Duct Mounted Field Installed TCI (Trane Communication Interface) LonTalk Interface Used with YC*151-301C w/Economizer YC*151-301C w/Economizer YC*151-301C YC*151-301C Mfg. Plant CK/001 CK/001 CK/001 CK/001 Shipping Weight 3 3.5 1 1
PG 85
PH 1
Features:
Variable speed indoor blower motors with Comfort-R airflow system Architectual Louvers and Corner Guards for durable protection and extra safety Appliance Grade Finish of durable powder paint baked on both sides of every panel Weather Beater top contoured and reinforced for strength Exclusive Climatuff high efficiency compressor All Aluminum Spine FinTM outdoor coil Swept-blade Outdoor fan for quiet operation Semi-Elliptical, Logarithmic Expansion Composite Vortica Blower uses less energy to provide more air with less sound Right-side electrical service access for high and low voltage connections Steeply sloped composite drain pan Shipped for horizontal application, easily convertible to downflow One electric heater family Optional filter rack kits fit inside the unit. Available for 1" or 2" media Low voltage polarized plug for easy electric heater installation Demand defrost control Refrigerant line filter drier Solenoid operated switchover valve Copper tube, aluminum fin indoor coil High efficiency outdoor fan motor with polarized plug Non-bleed expansion valve on
PH 2
PH 3
Model Mfg. Shipping Number Description Used With Plant Weight Extended Warranties (1 yr - 5 yr - 10 yr See Extended Warranty Section) Controls See Comfort Controls Section BAYCURB050A Roof Curb (Flat Roof)36 4WCY4024-036A FS/200 74 BAYCURB051A Roof Curb (Flat Roof)37 4WCY4048-060A FS/200 74 BAYECON101A 0-100% Mod. Economizer w/Baro. Relief12458 4WCY4024-036A FS/200 50 BAYECON102A 0-100% Mod. Economizer w/Baro. Relief12458 4WCY4048-060A FS/200 65 BAYECON200A 0-100% Mod. Econ. - Horizontal1248 4WCY4024-036A FS/200 85 BAYECON201A 0-100% Mod. Econ. - Horizontal1248 4WCY4048-060A FS/200 85 BAYRLAY004A Economizer Relay Kit1 All Economizers FS/200 1 BAYSTAT023 Remote Potentiometer All Economizers CK/001 1 BAYENTH001A Enthalpy Control (Solid State)4 All Economizers FS/200 2 BAYOSAH001A 0-25% Manual Fresh Air Damper25 4WCY4024-036A FS/200 6 BAYOSAH002A 0-25% Manual Fresh Air Damper25 4WCY4048-060A FS/200 8 BAYDMPR101A Motorized Fresh Air Damper25 4WCY4024-036A FS BAYDMPR102A Motorized Fresh Air Damper25 4WCY4048-060A FS BAYFLTR101A 1"-2" Filter Frame2 (20x20 filter not included) 4WCY4024-036A FS/200 6 BAYFLTR201A 1"-2" Filter Frame2 (20x25,20x18 filters not included) 4WCY4048-060A FS/200 6 BAYLOAM011A Evaporator Defrost Control Kit All WCY4 TY 5 BAYLOAM105A Low Ambient Control Kit All WCY4 FS/200 5 BAYQSTK300A Quick Start Kit All 4WCY4-A1 BAYCCHT101A Crankcase Heater - 230v - Recip 4WCY4024A1 BAYCCHT102A Crankcase Heater - 230v - Scroll 4WCY4036,048A1, 4WCY4036,048,060A3 BAYSQRD001A 16" Round Duct Adapter (2 Per Box)9 4WCY4024-036A FS/200 5 BAYSQRD002A 18" Round Duct Adapter (2 Per Box)9 4WCY4024-060A FS/200 3 BAYADAP050A Adapter Curb 4WCY4024-036A to BAYCURB030,38 BAYADAP051A Adapter Curb 4WCY4024-036A to BAYCURB033 BAYADAP052A Adapter Curb 4WCY4048-060A to BAYCURB030,38 BAYADAP053A Adapter Curb 4WCY4048-060A to BAYCURB033 BAYADAP054A Adapter Curb 4WCY4048-060A to BAYCURB034 BAYUTIL101A Roof Curb Utility Extention Kit 4WCY4024-036A BAYUTIL102A Roof Curb Utility Extention Kit 4WCY4048-060A BAYCOVR112A 12" Duct Shroud Covers Horizontal0 4WCY4024-060A BAYCOVR118A 18" Duct Shroud Covers Horizontal0 4WCY4024-060A BAYEXMK001A Extreme Condition Mounting Kit - All BAYCURB & BAYADAP BAYEXMK002A Extreme Condition Mounting Kit - All BAYUTIL BAYEXMK003A Extreme Condition Mounting Kit - All Slab Mounts BAYLIFT002B Lifting Lug Kit All 4WCY4 FS/200 5
1 Relay required with economizer on all 4WCY4 models. 2 Must use filter frame when economizer/fresh air kit is used. 3 Ships knocked down. 4 Dry bulb control standard with economizer. 5 Downflow Only. 6 Full perimeter curb for 4WCY4024-036A models. 7 Full perimeter curb for 4WCY4048-060A models. 8 2-Stage thermostat provides additional energy savings if simultaneous economizer and compressor operation is expected. 9 It is the responsibility of the installing dealer to properly size the ductwork for each specific application. 0 BAYCOVR112,118A will not cover BAYSQRD002A applications
PH 4
Features:
Architectual Louvers and Corner Guards for durable protection and extra safety Appliance Grade Finish of durable powder paint baked on both sides of every panel Weather Beater top contoured and reinforced for strength. Exclusive Climatuff high efficiency compressor All Aluminum Spine FinTM outdoor coil Swept-blade Outdoor fan for quiet operation Composite Vortica Blower uses less energy to provide more air with less sound Right-side electrical service access for high and low voltage connections Steeply sloped composite drain pan Shipped for horizontal application, easily convertible to downflow One electric heater family Optional filter rack kits fit inside the unit. Available for 1" or 2" media Heavy gauge steel cabinet with weather resistant, baked enamel finish Top discharge fan Low voltage polarized plug for easy electric heater installation Demand defrost control Refrigerant line filter drier Solenoid operated switchover valve Copper tube, aluminum fin indoor coil Non-bleed expansion valve on outdoor coil High efficiency outdoor fan motor with polarized plug Non-bleed expansion valve on indoor coil Water shed base UL Listed Direct drive multi-speed blower motor Compressor internal overload protection Protected pressure taps for refrigerant checks Standard cooling operation to 55F as manufactured Low ambient cooling to 0F with BAYLOAM105A 5-year compressor and other parts limited warranty (Residential Use Only) Optional extended warranties
PH 5
BAYSPEK062B
FS/200
FS/200
FS/200 FS/200
6 7
PH 6
Model Mfg. Shipping Number Description Used With Plant Weight Extended Warranties (1 yr - 5 yr - 10 yr See Extended Warranty Section) Controls See Comfort Controls Section BAYCURB050A Roof Curb (Flat Roof)36 *WCC3018-036A FS/200 74 BAYCURB051A Roof Curb (Flat Roof)37 *WCC3042-060A FS/200 74 BAYECON101A 0-100% Mod. Economizer w/Baro. Relief12458 *WCC3018-036A FS/200 50 BAYECON102A 0-100% Mod. Economizer w/Baro. Relief12458 *WCC3042-060A FS/200 65 BAYECON200A 0-100% Mod. Econ. - Horizontal1248 *WCC3018-036A FS/200 85 BAYECON201A 0-100% Mod. Econ. - Horizontal1248 *WCC3042-060A FS/200 85 BAYRLAY004A Economizer Relay Kit1 All Economizers FS/200 1 BAYSTAT023 Remote Potentiometer All Economizers CK/001 1 BAYENTH001A Enthalpy Control (Solid State)4 All Economizers FS/200 2 BAYOSAH001A 0-25% Manual Fresh Air Damper25 *WCC3018-036A FS/200 6 BAYOSAH002A 0-25% Manual Fresh Air Damper25 *WCC3042-060A FS/200 8 BAYDMPR101A Motorized Fresh Air Damper25 *WCC3018-036A FS BAYDMPR102A Motorized Fresh Air Damper25 *WCC3042-060A FS BAYFLTR101A 1"-2" Filter Frame2 (20x25 filter not included) *WCC3018-036A FS/200 6 BAYFLTR201A 1"-2" Filter Frame2 (20x20,20x18 filters not included) *WCC3042-060A FS/200 6 BAYLOAM011A Evaporator Defrost Control Kit All *WCC3 TY 5 BAYLOAM105A Low Ambient Control Kit All *WCC3 FS/200 5 BAYQSTK300A Quick Start Kit All 2/4WCC-A1 BAYCCHT101A Crankcase Heater - 230v - Recip 2WCC3024,30,48A1, 4WCC3018A1 BAYCCHT102A Crankcase Heater - 230v - Scroll 2WCC3036,42A1, 4WCC3036,48,60A1/3 BAYCCHT404B Crankcase Heater - 460v - Scroll 4WCC30306,48,60A4 BAYSQRD001A 16" Round Duct Adapter (2 Per Box)9 *WCC3018-036A FS/200 5 BAYSQRD002A 18" Round Duct Adapter (2 Per Box)9 *WCC3018-060A FS/200 3 BAYADAP050A Adapter Curb *WCC3018-036A to BAYCURB030,38 BAYADAP051A Adapter Curb *WCC3018-036A to BAYCURB033 BAYADAP052A Adapter Curb *WCC3042-060A to BAYCURB030,38 BAYADAP053A Adapter Curb *WCC3042-060A to BAYCURB033 BAYADAP054A Adapter Curb *WCC3042-060A to BAYCURB034 BAYUTIL101A Roof Curb Utility Extention Kit *WCC3018-036A BAYUTIL102A Roof Curb Utility Extention Kit *WCC3042-060A BAYCOVR112A 12" Duct Shroud Covers Horizontal0 *WCC3018-060A BAYCOVR118A 18" Duct Shroud Covers Horizontal0 *WCC3018-060A BAYEXMK001A Extreme Condition Mounting Kit - All BAYCURB & BAYADAP BAYEXMK002A Extreme Condition Mounting Kit - All BAYUTIL BAYEXMK003A Extreme Condition Mounting Kit - All Slab Mounts BAYLIFT002B Lifting Lug Kit All *WCC3 FS/200 5
1 Relay required with economizer on all 2/4WC*3 models. 2 Must use filter frame when economizer/fresh air kit is used. 3 Ships knocked down. 4 Dry bulb control standard with economizer. 5 Downflow Only. 6 Full perimeter curb for 2/4WCC3018-036A models. 7 Full perimeter curb for 2/4WCC3042-060A models. 8 2-Stage thermostat provides additional energy savings if simultaneous economizer and compressor operation is expected. 9 It is the responsibility of the installing dealer to properly size the ductwork for each specific application. 0 BAYCOVR112,118A will not cover BAYSQRD002A applications
PH 7
Features:
Architectual Louvers and Corner Guards for durable protection and extra safety Appliance Grade Finish of durable powder paint baked on both sides of every panel Weather Beater top contoured and reinforced for strength Exclusive Climatuff high efficiency compressor All Aluminum Spine FinTM outdoor coil Swept-blade Outdoor fan for quiet operation Composite Vortica Blower uses less energy to provide more air with less sound Right-side electrical service access for high and low voltage connections Steeply sloped composite drain pan Shipped for horizontal application, easily convertible to downflow One electric heater family Optional filter rack kits fit inside the unit. Available for 1" or 2" media Low voltage polarized plug for easy electric heater installation Demand defrost control Refrigerant line filter drier Solenoid operated switchover valve Copper tube, aluminum fin indoor coil Non-bleed expansion valve on outdoor coil High efficiency outdoor fan motor with polarized plug Non-bleed expansion valve on indoor coil Water shed base UL Listed Direct drive multi-speed blower motor Compressor internal overload protection Protected pressure taps for refrigerant checks Standard cooling operation to 55F as manufactured Low ambient cooling to 0F with BAYLOAM105A 10-year limited compressor and outdoor coil warranty, 5-year other parts single phase (Residential Use Only) Optional extended warranties
PH 8
BAYSPEK062B
FS/200
FS/200
FS/200 FS/200
6 7
PH 9
Model Mfg. Shipping Number Description Used With Plant Weight Extended Warranties (1 yr - 5 yr - 10 yr See Extended Warranty Section) Controls See Comfort Controls Section BAYCURB050A Roof Curb (Flat Roof)36 *WCX3018-036A FS/200 74 BAYCURB051A Roof Curb (Flat Roof)37 *WCX3042-060A FS/200 74 BAYECON101A 0-100% Mod. Economizer w/Baro. Relief12458 *WCX3018-036A FS/200 50 BAYECON102A 0-100% Mod. Economizer w/Baro. Relief12458 *WCX3042-060A FS/200 65 BAYECON200A 0-100% Mod. Econ. - Horizontal1248 *WCX3018-036A FS/200 85 BAYECON201A 0-100% Mod. Econ. - Horizontal1248 *WCX3042-060A FS/200 85 BAYRLAY004A Economizer Relay Kit1 All Economizers FS/200 1 BAYSTAT023 Remote Potentiometer All Economizers CK/001 1 BAYENTH001A Enthalpy Control (Solid State)4 All Economizers FS/200 2 BAYOSAH001A 0-25% Manual Fresh Air Damper25 *WCX3018-036A FS/200 6 BAYOSAH002A 0-25% Manual Fresh Air Damper25 *WCX3042-060A FS/200 8 BAYDMPR101A Motorized Fresh Air Damper25 *WCX3018-036A FS BAYDMPR102A Motorized Fresh Air Damper25 *WCX3042-060A FS BAYFLTR101A 1"-2" Filter Frame2 (20x25 filter not included) *WCX3018-036A FS/200 6 BAYFLTR201A 1"-2" Filter Frame2 (20x20,20x18 filters not included) *WCX3042-060A FS/200 6 BAYLOAM011A Evaporator Defrost Control Kit All *WCX3 TY 5 BAYLOAM105A Low Ambient Control Kit All *WCX3 FS/200 5 BAYQSTK300A Quick Start Kit All 2/4WCX-A1 BAYCCHT101A Crankcase Heater - 230v - Recip 2WCX3024,30,48A1, 4WCX3018A1 BAYCCHT102A Crankcase Heater - 230v - Scroll 2WCX3036,42A1, 4WCX3036,48,60A1/3 BAYCCHT404B Crankcase Heater - 460v - Scroll 4WCX30306,48,60A4 BAYSQRD001A 16" Round Duct Adapter (2 Per Box)9 *WCX3018-036A FS/200 5 BAYSQRD002A 18" Round Duct Adapter (2 Per Box)9 *WCX3018-060A FS/200 3 BAYADAP050A Adapter Curb *WCX3018-036A to BAYCURB030,38 BAYADAP051A Adapter Curb *WCX3018-036A to BAYCURB033 BAYADAP052A Adapter Curb *WCX3042-060A to BAYCURB030,38 BAYADAP053A Adapter Curb *WCX3042-060A to BAYCURB033 BAYADAP054A Adapter Curb *WCX3042-060A to BAYCURB034 BAYUTIL101A Roof Curb Utility Extention Kit *WCX3018-036A BAYUTIL102A Roof Curb Utility Extention Kit *WCX3042-060A BAYCOVR112A 12" Duct Shroud Covers Horizontal0 *WCX3018-060A BAYCOVR118A 18" Duct Shroud Covers Horizontal0 *WCX3018-060A BAYEXMK001A Extreme Condition Mounting Kit - All BAYCURB & BAYADAP BAYEXMK002A Extreme Condition Mounting Kit - All BAYUTIL BAYEXMK003A Extreme Condition Mounting Kit - All Slab Mounts BAYLIFT002B Lifting Lug Kit All *WCX3 FS/200 5
1 Relay required with economizer on all 2/4WCX3 models. 2 Must use filter frame when economizer/fresh air kit is used. 3 Ships knocked down. 4 Dry bulb control standard with economizer. 5 Downflow Only. 6 Full perimeter curb for 2/4WCX3018-036A models. 7 Full perimeter curb for 2/4WCX3042-060A models. 8 2-Stage thermostat provides additional energy savings if simultaneous economizer and compressor operation is expected. 9 It is the responsibility of the installing dealer to properly size the ductwork for each specific application. 0 BAYCOVR112,118A will not cover BAYSQRD002A applications
PH 10
Uncrated Dimensions(in.) H W L 31 32 44 31 32 44 31 32 44 31 32 44
Accessories:
Model Number Extended Warranties BAYSTAT033A TAYASCT501A1 BAYLOAM011A BAYASCT0011 Description (See Extended Warranty Section) Outdoor Thermostat 5-7 Minute Delay Relay Low Ambient Cooling Kit Anti-Short Cycle Timer Used With All WCK Models All WCK Models All WCK Models All WCK Models Mfg. Plant TY TY FS/200 FS/200 Shipping Weight 4 2 5 1
Features:
Climatuff compressor Compressor motor overload protection Energy Saving Demand Defrost control system Copper tube, aluminum fin coils Shaft-down outdoor fan system for quiet operation Steeply sloped composite drain pan eliminates standing water Waterproof closed-cell foam evaporator base insulation Weather resistant powder paint Powder painted base pan 14" round duct connections included Wrap-around vinyl-coated wire coil guards Extra quiet operation Non-bleed thermal expansion valves External pressure taps for refrigerant checks Polarized plug for easy field connection of low voltage to supplementary heaters Low ambient cooling to 45 F as manufactured Low ambient cooling to 0 F with accessory BAYLOAM011A UL listed 5-year limited warranty on compressor, and 5-year on all other parts (Residential Use Only) Optional extended warranties
PH 11
Features:
Industry's highest efficiency -- 15+ SEER Coil-Sav'R Lexan wrap-around grille Powder paint and WeatherguardTM screws for a quality appearance that lasts Impack PlusTM cabinet enhancement Acousti-Curb for rooftop applications Exclusive dual Climatuff high efficiency compressors Exclusive Comfort-RTM enhanced comfort setting Exclusive Water-Shed no leak one piece base pan DuratuffTM outdoor plate fin coil Demand defrost system One electric heater family (WCZ, WCY, WCC, TCY, TCC) Polarized plug for easy heater installation Refrigerant line filter drier Ships for horizontal application; easily convertible to downflow Exclusive trim ring on top discharge fan grille Optional In-FilterTM filter rack fits inside unit Expansion valves on outdoor and indoor coil High efficiency outdoor fan motor with polarized plug UL listed Crankcase heater Compressor IOL protection Standard operation to 55F Low ambient cooling to 0F with accessories 10-year limited compressor and outdoor coil warranty, 5-years on other parts (Residential Use Single Phase Only) Optional extended warranties
PH 12
Accessories:
Model Number Description Used With Extended Warranties - (1 yr - 5 yr - 10 yr - See Extended Warranty Section) BAYCURB033A Roof Curb (Flat Roof)3 Acousti-Curb WCZ036F BAYCURB034A Roof Curb (Flat Roof)3 Acousti-Curb WCZ060F BAYINDK002A** Insulated Deck Pan for C Cabinet BAYCURB033A BAYINDK003A*** Insulated Deck Pan for D Cabinet BAYCURB034A BAYECON054B 0-100% Mod. Economizer w/Baro.Relief12457 WCZ036F BAYECON055B 0-100% Mod. Economizer w/Baro.Relief12457 WCZ060F BAYECON073A 0-100% Mod. Econ. - Horizontal127 WCZ-F Models BAYSTAT023 Remote Potentiometer All Economizers BAYENTH001A Enthalpy Control (Solid State)2 WCZ-F Models BAYOSAC001A Outside Air Controller WCZ-F Models BAYRLAY004A Economizer Relay Kit5 WCZ-F Models BAYDMPR040A 0-25% Manual Fresh Air Damper1 WCZ036F BAYDMPR041A 0-25% Manual Fresh Air Damper1 WCZ060F BAYFLTR013A Filter Frame1 (20x25x1" filter not included) WCZ036F BAYFLTR014A Filter Frame1 (3-10x24x1" filters not included) WCZ060F BAYFLTR018A Filter Frame1 (1-20x25x2" filter not included) WCZ036F BAYFLTR019A Filter Frame1 (2-16x25x2" filters not included) WCZ060F BAYLOAM011A Evaporator Defrost Control Kit WCZ-F Models BAYDUCT004A 12" Round Duct Adapter (2 Per Box)6 WCZ036F BAYDUCT005A 14" Round Duct Adapter (1 Per Box)6 WCZ036F BAYLIFT002B Lifting Lug Kit WCZ-F Models BAYASCT001 Anti-Short Cycle Timer8 WCZ-F Models
1 Must use filter frame when economizer/fresh air kit is used. 2 Dry bulb control standard with economizer. 3 Ships knocked down. 4 Downflow Only. 5 Relay required with economizer on WCY-Z models. 6 It is the responsibility of the installing dealer to properly size the ductwork for each specific application. 7 For low ambient applications, use this controller. 8 Do not use with programmable thermostats. ** Currently shipped with BAYCURB033A *** Currently shipped with BAYCURB034A
Mfg. Shipping Plant Weight FS/200 FS/200 FS/200 FS/200 FS/200 FS/200 FS/200 CK/001 FS/200 FS/200 FS/200 FS/200 FS/200 FS/200 FS/200 FS/200 FS/200 TY FS/200 FS/200 FS/200 FS/200 88 100 28 30 50 65 85 1 2 1 6 8 6 9 6 9 5 5 3 5 1
PH 13
Description 3.74/4.98 kW Heater (208/240V 1PH) 5.76/7.68 kW Heater (208/240V 1PH) 7.47/9.96 kW Heater (208/240V 1PH) 8.65/11.52 kW Heater (208/240V 1PH 11.21/14.94 kW Heater (208/240V 1PH) 12.98/17.28 kW Heater (208/240V 1PH) 17.2/23.04 kW Heater (208/240V 1PH) 4.89/6.25 kW Heater (208/240V 3PH) 7.45/9.96 kW Heater (208/240V 3PH) 7.45/9.96 kW Heater (208/240V 3PH) 11.25/14.90 kW Heater (208/240V 3PH) 14.96/19.92 kW Heater (208/240V 3PH) 22.41/29.80 kW Heater (208/240V 3PH)
Used With WCZ036-042F1 WCZ036-042F1 WCZ036-060F1 WCZ036-060F1 WCZ036-060F1 WCZ036-060F1 WCZ060F1 WCZ036-060F3 WCZ036-060F3 WCZ036-060F3 WCZ036-060F3 WCZ036-060F3 WCZ060F3
BAYSPEK050A BAYSPEK051A
FS/200 FS/200
7 7
BAYSPEK052A
FS/200
BAYSPEK053A
FS/200
PH 14
Single Phase
HSPF 7.70 7.70 7.70 7.70 8.00 8.20 Uncrated Dimensions(in.) H W L 30 32 44 30 32 44 30 32 44 30 32 44 33 45 58 33 45 58 Mfg. Shipping Plant Weight FS/200 329 FS/200 330 FS/200 345 FS/200 359 FS/200 521 FS/200 529
Supplementary Heaters:
Model Number BAYHTRC106A BAYHTRC109A BAYHTRC110A BAYHTRC111A BAYHTRC117A
Description 4.33/5.76 KW Heater (208/240) 6.12/8.16 KW Heater (208/240) 7.93/10.56 KW Heater (208/240) 7.93/10.56 KW Heater (208/240) 12.98 /17.28 KW Heater (208/240)1
Mfg. Shipping Used With Plant Weight WCH024-060C/F1 FS/200 9 WCH036-042C1,048-060F1 FS/200 10 WCH048F1 only FS/200 10 WCH024-042C1,060F1 FS/200 10 WCH030-060C/F1 FS/200 23
Features:
Climatuff compressor Compressor sump heat Compressor internal overload protection Solenoid operated switchover valve Demand defrost control system Factory installed coil guard Multi-speed direct drive blower motor Variable speed direct drive blower motor on WCH042C, WCH048-060F models Weather resistant Powder Paint Copper tube, aluminum fin coils Top discharge condensing fan Indoor fan relay Wrap-around coil guard Top access to supplementary heater Over (supply) under (return) air Expansion valves Pressure taps for refrigerant checks Polarized plug for easy field connection of low voltage to supplementary heaters Low ambient cooling to 45F as manufactured Low ambient cooling to 0F with accessory BAYLOAM011A UL listed 5-year limited warranty on compressor and 5-year on all other parts (Residential Use Only) Optional extended warranties
PH 15
Accessories:
Model Number Extended Warranties Controls TAYASCT501A1 BAYLOAM011A BAYASCT0011 Description Used With (1 yr - 5 yr - 10 yr - See Extended Warranty Section) (See Control Section) 5 Minute Delay Relay All WCH Models Low Ambient Cooling Kit All WCH Models Anti-Short Cycle Timer All WCH Models Mfg. Plant Shipping Weight
TY FS/200 FS/200
2 5 1
PH 16
Model Nomenclature
W S 1 2
036
3 8
R B 9 10
**
3 4,5,6 7
11 12,13 14 15 16
17 18 19
21 22
DIGIT 1 - Unit Function W = Packaged Heat Pump DIGIT 2 - Efficiency S = Standard Efficiency DIGIT 3 - Airflow C = Convertible DIGITS 4,5,6 - Nominal Gross Cooling Capacity (MBh) 036 = 3 Ton 048 = 4 Ton 060 = 5 Ton 072 = 6 Ton 090 = 7.5 Ton 120 = 10 Ton DIGIT 7 - Major Design Sequence A = First DIGIT 8 - Unit Voltage 3 = 208-230/60/3 4 = 460/60/3 W = 575/60/3 DIGIT 9 - Unit Controls R = ReliaTelMicro-processor DIGIT 10 - Electric Heater 0 = No Electric Heater B = 6 kw (3 phase) E = 12 kw (3 phase) G = 18 kw (3 phase) J = 23 kw (3 phase) K = 27 kw (3 phase) N = 36 kw (3 phase) P = 54 kw (3 phase) DIGIT 11 - Minor Design Sequence A = First Sequence DIGIT 12,13 - Service Sequence ** = Factory Assigned
DIGIT 14 - Fresh Air Selection 0 = No Fresh Air A = Manual Outside Air Damper 0-50% B = Motorized Outside Air Damper 0-50% C = Economizer, Dry Bulb 0-100% without Barometric Relief D = Economizer, Dry Bulb 0-100% with Barometric Relief E = Economizer, Reference Enthalpy 0-100% without Barometric Relief F = Economizer, Reference Enthalpy 0-100% with Barometric Relief G = Economizer, Comparative Enthalpy 0-100% without Barometric Relief H = Economizer, Comparative Enthalpy 0-100% with Barometric Relief DIGIT 15 - Supply Fan/Drive Type/Motor 0 = Standard Drive 1 = Oversized Motor 2 = Optional Belt Drive Motor DIGIT 16 - Hinged Service Access & Pleated Filters 0 = Standard Panels & Filters A = Hinged Access Panels & Standard Filters B = Standard Panels & 2" Pleated Filters C = Hinged Access Panels & 2" Pleated Filters DIGIT 17 - Condenser Coil Protection 0 = Standard Coil 1 = Standard Coil with Hail Guard 2 = Epoxy Coated Condenser Coil 3 = Epoxy Coated Condenser Coil with Hail Guard DIGIT 18 - Through the Base Provisions 0 = No Through the Base Provisions A = Through the Base Electric DIGIT 19 - Disconnect/Circuit Breaker/ Phase Monitor (3 phase only) 0 = No Disconnect or Circuit Breaker 1 = Non-Fused Disconnect 2 = Circuit Breaker 3 = Phase Monitor 4 = Phase Monitor & Non-Fused Disconnect Switch 5 = Phase Monitor & Circuit Breaker
DIGIT 20 - Convenience Outlet 0 = No Convenience Outlet A = Unpowered Convenience Outlet B = Powered Convenience Outlet (3 phase only) DIGIT 21 - Communications Options 0 = No Communications Interface 1 = Comm-3/4 Trane Communications Interface 2 = LonTalk Communications Interface DIGIT 22 - Refrigeration System Option 0 = Standard Refrigeration System DIGIT 23 - Refrigeration Controls 0 = No Refrigeration Control 1 = High Pressure Control 2 = Frostat 3 = Crankcase Heater 4 = High Pressure Control and Frostat 5 = High Pressure Control and Crankcase Heater 6 = Frostat and Crankcase Heater 7 = High Pressure Control, Frostat and Crankcase Heater DIGIT 24 - Smoke Detector 0 = No Smoke Detector A = Return Air Smoke Detector B = Supply Air Smoke Detector C = Supply and Return Air Smoke Detectors DIGIT 25 - Monitoring Controls 0 = No Monitoring Control 1 = Clogged Filter Switch 2 = Fan Failure Switch 3 = Discharge Air Sensing Tube 4 = Clogged Filter Switch and Fan Fail Switch 5 = Clogged Filter Switch and Discharge Air Sensing Tube 6 = Fan Fail Switch and Discharge Air Sensing Tube 7 = Clogged Filter and Fan Fail Switches and Discharge Air Sensing Tube
Example: Model number WSC036A3RBA**C000A10001A0 describes a unit with the following characteristics: Packaged Heat Pump, 3 ton nominal cooling capacity, 208-230/60/3 power supply, ReliaTel controls, 6 kw electric heater model. 0-100% dry bulb economizer without barometric relief, standard direct drive motor, standard access panels and filters, standard condenser coil with no coil protection, through the base electric access, non-fused disconnect, no convenience outlet or communications interface, standard refrigeration coil, no refrigeration control, return air smoke detector, and clogged filter switch.
PH 17
Power Supply 208-230/60/3 208-230/60/3 208-230/60/3 208-230/60/3 208-230/60/3 208-230/60/3 460/60/3 460/60/3 460/60/3 460/60/3 460/60/3 460/60/3 575/60/3 575/60/3 575/60/3 575/60/3 575/60/3 575/60/3
Gross Capacity Cooling (BTUH) 38,100 50,800 63,100 72,000 92,000 119,000 38,100 50,800 63,100 72,000 92,000 119,000 38,100 50,800 63,100 72,000 92,000 119,000
SEER1 10.2 10.5 10.1 10.1 10.1 10.1 10.2 10.5 10.1 10.1 10.1 10.1 10.2 10.5 10.1 10.1 10.1 10.1
Mfg. Plant LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH
Shipping Weight 496 528 546 859 881 1028 425 460 482 859 881 1028 425 460 482 859 881 1028
PH 18
PH 19
Tons 3 4 5 6 7.5 10
Tons 3 4 5 6 7.5 10
1 Economizer with Barometric Relief is for downflow configured units only. Order Economizer without Barometric Relief for horizontal configuration. Barometric relief for horizontal configured units must be ordered as field installed accessory BAYBARM010A. (Page PR-HP-11) 2 The Manual Outside Air Damper will ship factory supplied (field installed) within the unit. The option will no longer be factory installed.
1 Available for 3 phase 3-5 ton models only. 2 Standard motor in 3-5 ton models is direct drive. Standard motor in 6-10 ton models is belt drive. 3 Oversized Motor for 3-5 ton models is direct drive. Oversized motor in 6-10 ton models is belt drive.
1 3-5 tons have standard 1" throwaway filters. 6-10 tons have standard 2" throwaway filters.
PH 20
Unit Mounted Unit Mounted Non-Fused Circuit Disconnect Switch (1) Breaker (2)
Phase Monitor & Phase Monitor & Non-Fused Circuit Disconnect Switch (4) Breaker (5)
Disconnect/Circuit Breaker/Phase Monitor is available for 3 phase models only. Must order Through the Base option when ordering disconnect or Breaker. Phase Monitor is available with ReliaTel models only. Phase monitor will be standard on W_C060A3,4,W (three phase).
1 Powered Convenience Outlet Option is available for 3 phase models only. 2 Requires use of Disconnect or Circuit Breaker.
PH 21
1 Standard Refrigeration Metering Device - Thermal Expansion Valve (Outdoor Coil), Short Orifice (Indoor Coil).
1 High Pressure Control is standard on 3-phase units with scroll compressors and on WSC036A. 2 Crankcase heater is standard on WSC036A. 3 High Pressure Control is standard on all three-phase models.
PH 22
1 Cannot be used with BAYFRST001A High Temperature Stat accessory. 2 The return air smoke detector may not fit up or work properly on the Precedent units when used in conjuntcion with 3rd party accessories (such as bolt on heat wheels, economizers, and power exhaust). Do not order the return air smoke detectors when using this type of accessory.
1 Combination of Discharge Air Sensing option, Economizer option and Tracer Summit or Tracker, Version 10 requires use of Tracer LCI-R Communications Interface. For jobs requiring true discharge air sensing with Tracer/Tracker COMM-3 or COMM-4, contact Clarksville Light Commercial Marketing Support.
PH 23
Accessory Electric Heaters: Unit with heater is single circuit / single point power entry
Model Number BAYHTRR306A BAYHTRR312A BAYHTRR318A BAYHTRR323A Power Supply 208/240/60/3 208/240/60/3 208/240/60/3 208/240/60/3 KW Rating 4.5/6.0 9.0/12.0 13.0/17.4 17.3/23.0 Nominal No. of BTUH Stages 13,400/ 1 20,500 30,800/ 2 41,000 44,600/ 2 59,400 58,900/ 2 78,500 20,500 41,000 59,400 78,500 20,500 41,000 59,400 78,500 1 2 2 2 1 2 2 2 Used With WSC036-060A3 WSC036-060A3 WSC036-060A3 WSC060A3 Mfg. Plant SH SH SH SH Shipping Weight 20 20 20 20
SH SH SH SH SH SH SH SH
20 20 20 20 20 20 20 20
PH 24
Accessory Electric Heaters 6-10 Tons: Unit with heater is single circuit / single point power entry
Model Number BAYHTRS309A BAYHTRS318A BAYHTRT318A BAYHTRS327A BAYHTRT327A BAYHTRS336A BAYHTRT336A BAYHTRT354A Power Supply 208/240/60/3 208/240/60/3 208/240/60/3 208/240/60/3 208/240/60/3 208/240/60/3 208/240/60/3 208/240/60/3 KW Rating 6.75/9.0 13.5/18.0 13.5/18.0 20.3/27.0 20.3/27.0 27.0/36.0 27.0/36.0 40.4/54.0 Nominal No. of BTUH Stages 23,000/ 1 30,700 46,100/ 1 61,400 46,100/ 1 61,400 69,000/ 2 92,100 69,000/ 2 92,100 92,200/ 2 122,900 92,200/ 2 122,900 138,200/ 2 184,300 30,700 61,400 61,400 92,100 92,100 122,900 122,900 184,300 30,700 61,400 61,400 92,100 92,100 122,900 122,900 184,300 1 1 1 2 2 2 2 2 1 1 1 2 2 2 2 2 Used With WSC072-090A3 WSC072-090A3 WSC120A3 WSC072-090A3 WSC120A3 WSC072-090A3 WSC120A3 WSC120A3
BAYHTRS409A BAYHTRS418A BAYHTRT418A BAYHTRS427A BAYHTRT427A BAYHTRS436A BAYHTRT436A BAYHTRT454A BAYHTRSW09A BAYHTRSW18A BAYHTRTW18A BAYHTRSW27A BAYHTRTW27A BAYHTRSW36A BAYHTRTW36A BAYHTRTW54A
460/60/3 460/60/3 460/60/3 460/60/3 460/60/3 460/60/3 460/60/3 460/60/3 575/60/3 575/60/3 575/60/3 575/60/3 575/60/3 575/60/3 575/60/3 575/60/3
9.0 18.0 18.0 27.0 27.0 36.0 36.0 54.0 9.0 18.0 18.0 27.0 27.0 36.0 36.0 54.0
WSC072-090A4 WSC072-090A4 WSC120A4 WSC072-090A4 WSC120A4 WSC072-090A4 WSC120A4 WSC120A4 WSC072-090AW WSC072-090AW WSC120AW WSC072-090AW WSC120AW WSC072-090AW WSC120AW WSC120AW
SH SH SH SH SH SH SH SH SH SH SH SH SH SH SH SH
26 28 28 26 26 31 31 38 26 28 28 26 26 31 31 38
PH 25
Accessories:
Model Number BAYCURB042A1 BAYCURB043A1 BAYQACB009A1 BAYQACB010A1 BAYQACB011A1 BAYQACB012A1 BAYECON085A BAYECON087A BAYDMPR051A BAYDMPR054A BAYDMPR053B BAYDMPR056B BAYGARD036B BAYGARD040B BAYGARD041B BAYHSMT073A BAYHSMT074A BAYHSMT075A BAYHSMT076A BAYHSMT077A BAYHSMT078A BAYHSMT079A BAYHSMT080A BAYHSMT081A Description Roof Curb Roof Curb Quick Adapt Roof Curb24 Quick Adapt Roof Curb24 Quick Adapt Roof Curb34 Quick Adapt Roof Curb34 0-100% Economizer without Barometric Relief 0-100% Economizer without Barometric Relief 0-50% Motorized Outside Air Damper 0-50% Motorized Outside Air Damper 0-50% Manual Outside Air Damper 0-50% Manual Outside Air Damper Tool-less Condenser Coil Hail Guard Tool-less Condenser Coil Hail Guard Tool-less Condenser Coil Hail Guard .45HP Direct Drive Oversized Motor .45HP Direct Drive Oversized Motor .45HP Direct Drive Oversized Motor .75HP Direct Drive Oversized Motor .75HP Direct Drive Oversized Motor .75HP Direct Drive Oversized Motor 1.2HP Direct Drive Oversized Motor 1.2HP Direct Drive Oversized Motor 1.2HP Direct Drive Oversized Motor Used With WSC036-060A WSC072-120A WSC036-060A2 WSC036-060A2 WSC036-120A3 WSC036-120A3 WSC036-060A WSC072-120A WSC036-060A WSC072-120A WSC036-060A WSC072-120A WSC036-060A WSC072,090A WSC120A3 WSC036A3 WSC036A4 WSC036AW WSC048A3 WSC048A4 WSC048AW WSC060A3 WSC060A4 WSC060AW Mfg. Plant LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH Shipping Weight 80 115 100 120 125 150 40 36 30 30 25 26 10 20 20 25 25 25 30 30 30 45 45 45
1 Lynn Haven manufacturing has a no return policy for this roof curb. 2 BAYQACB009A adapts Voyager BAYCURB021 roof curb to accept Precedent 3-5 ton unit. BAYQACB010A adapts Voyager BAYCURB022 roof curb to accept Precedent 3-5 ton unit. 3 BAYQACB011A adapts Voyager BAYCURB022B to accept Precedent 6-10 ton unit. BAYQACB012A adapts Voyager BAYCURB025 roof curb to accept Precedent 6-10 ton unit. 4 TCD036A, TCD048A, TCD060A, WCD036A, WCD048A, WCD060A are not Voyager units. These units were manufactured in Ft. Smith, AR and will not fit any Voyager curbs.
PH 26
Description
2 HP Belt Drive Oversized Motor 2 HP Belt Drive Oversized Motor 3 HP Belt Drive Oversized Motor 3 HP Belt Drive Oversized Motor 5 HP Belt Drive Oversized Motor 5 HP Belt Drive Oversized Motor ReliaTel Options Module Barometric Relief Barometric Relief Power Exhaust Power Exhaust Power Exhaust CO2 Sensor Kit, Wall Mounted CO2 Sensor Kit, Duct Mounted Crankcase Heater Crankcase Heater Crankcase Heater Crankcase Heater Crankcase Heater Remote Potentiometer Selective Resistance Service Tester Temperature Sensor High Temperature Stat Reference Enthalpy Kit Comparative Enthalpy Kit Clogged Filter Switch Fan Failure Switch Discharge Air Sensing Kit Discharge Air Sensing Kit Comm-3/4 Trane Communications Interface LonTalk Communications Interface Evaporator Defrost Control (Frostat) High Static Drive Kit Ventilation Override Kit
Used With
WSC072A3,A4 LH WSC072AW LH WSC090A3,A4 LH WSC090AW LH WSC120A3,A4 LH WSC120AW LH See Note4 LH WSC036-060A LH WSC072-120A LH WSC072-120A3 LH WSC072-120A4 LH WSC072-120AW LH WSC036-120A*R LH W/Econ. or Motorized OA Damper WSC036-120A*R LH W/Econ. or Motorized OA Damper WSC036-072A3 LH WSC092-120A3 WSC036-072A4,AW LH WSC092-120A4,AW WSC090A3 LH WSC090A4 LH WSC090AW LH BAYECON085A,087A CK/001 WSC036-120A LH WSC036-120A WSC036-120A BAYECON085A,087A BAYECON085A,087A WSC036-120A WSC036-120A WSC036-060A WSC072-120A WSC036-120A WSC036-120A LH CK/001 LH LH LH LH LH LH LH LH
1 Kits contain all necessary parts to achieve desired level of enthalpy control. 2 Used for true discharge air sensing in both heating and cooling. Required for supply air tempering. 3 Barometric Relief accessory installs in ductwork for horizontal configuration. For downflow configuration, installs in the unit's horizontal return duct. See Installer's Guide for complete instructions. 4 BAYABRD001C is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS003A), Fan Fail Switch (BAYDFPS004A), Discharge Air Sensing Kit (BAYTUBE004A or BAYTUBE005A) or Evaporator Defrost Control (Frostat) (BAYLOAM020B) unless the following options are factory installed: Frostat, Smoke Detector, Clogged Filter Switch, Fan Failure Switch, Discharge Air Sensing Kit. These factory installed options include the ReliaTel Options Module. 5 Cannot be used in conjunction with factory installed smoke detector. 6 Interface allows unit to communicate with Tracer 100, Tracker, VariTrac II, and is the preferred methodof communication to Tracer Summit. 7 Interface allows unit to communicate as a Trane LonTalk device or directly with generic LonTalk Network BAS Controls. 8 Power Exhaust cannot be used with Barometric Relief. Order Economizer without Barometric Relief. 9 Quantity 2 required for WSC120A. 0 For use with ReliaTel controlled units only.
PH 27
1 Used with Integrated ComfortTM Systems, any unit type. These sensors do not work with TCM. Consult BASD Marketing for them. 2 See Accessory IOM for operational characteristics. 3 Functional only with ReliaTel controls.
PH 28
Model Nomenclature
W 1
S 2
C 036 E 3 4,5,6 7
3 8
R B 9 10
A ** C 0 0 11 12,13 14 15 16
0 A 1 17 18 19
DIGIT 1 - Unit Function W = Packaged Heat Pump1 DIGIT 2 - Efficiency S = Standard Efficiency (13 SEER R-410A) DIGIT 3 -Airflow C = Convertible DIGITS 4,5,6 - Nominal Gross Cooling Capacity (MBh) 036 = 3 Ton 046 = 4 Ton 060 = 5 Ton DIGIT 7 - Major Design Sequence E = R-410A Refrigerant DIGIT 8 - Unit Voltage 1 = 208-230/60/1 3 = 208-230/60/3 4 = 460/60/3 W = 575/60/3 DIGIT 9 - Unit Controls R = ReliaTelMicroprocessor DIGIT 10 - Heating Capacity Note: (Applicable to Digit 1, W models only) 0 = No Electric Heat A = 5 kW (1 phase)1 B = 6 kW (3 phase) C = 9 kW (3 phase)3 D = 10 kW (1 phase)1 E = 12 kW (3 phase) F = 14 kW (1 phase)1 G = 18 kW (1&3phase) J = 23 kW (3 phase) DIGIT 11 - Minor Design Sequence A = First Sequence DIGITS 12, 13 - Service Sequence ** = Factory Assigned DIGIT 14 - Fresh Air Selection 0 = No Fresh Air A = Manual Outside Air Damper 0-50%5 B = Motorized Outside Air Damper 0-50% C = Economizer, Dry Bulb 0-100% without Barometric Relief8 D = Economizer, Dry Bulb 0-100% with Barometric Relief8 E = Economizer, Reference Enthalpy 0-100% without Barometric Relief48 F = Economizer, Reference Enthalpy 0-100% with Barometric Relief48 G = Economizer, Comparative Enthalpy 0-100% without Barometric Relief48 H = Economizer, Comparative Enthalpy 0-100% with Barometric Relief48
DIGIT 15 - Supply Fan/Drive Type/Motor 0 = Standard Drive7 DIGIT 16 - Hinged Service Access/Filters 0 = Standard Panels/Standard Filters A = Hinged Access Panels/Standard Filters B = Standard Panels/2 Pleated Filters C = Hinged Access Panels/2 Pleated Filters DIGIT 17 - Condenser Coil Protection 0 = Standard Coil 1 = Standard Coil with Hail Guard 2 = Epoxy Coated Condenser Coil 3 = Epoxy Coated Condenser Coil with Hail Guard 4 = CompleteCoat Condenser Coil 5 = CompleteCoat Condenser Coil with Hail Guard DIGIT 18 - Through the Base Provisions Note: (Applicable to Digit 1, W models only) 0 = No Through the Base Provisions A = Through the Base Electric9 DIGIT 19 - Disconnect/Circuit Breaker/ Phase Monitor (3 phase only) 0 = No Disconnect/No Circuit Breaker/No Phase Monitor 1 = Unit Mounted Non-Fused Disconnect9 2 = Unit Mounted Circuit Breaker9 3 = Phase Monitor 4 = Phase Monitor & Non-Fused Disconnect Switch 5 = Phase Monitor & Circuit Breaker DIGIT 20 - Convenience Outlet 0 = No Convenience Outlet A = Unpowered Convenience Outlet B = Powered Convenience Outlet (3 phase only)0 DIGIT 21 - Communications Options4 0 = No Communications Interface 1 = Trane Communications Interface 2 = LonTalk Communications Interface DIGIT 22 - Refrigeration System Option 0 = Standard Refrigeration Coilq DIGIT 23 - Refrigeration Controls 0 = No Refrigeration Control6 1 = Frostatw 2 = Crankcase Heater2 3 = Frostatw and Crankcase Heater DIGIT 24 - Smoke Detector4u 0 = No Smoke Detector A = Return Air Smoke Detectorer B = Supply Air Smoke Detector C = Supply and Return Air Smoke Detectorser
DIGIT 25 - Monitoring Controls5 0 = No Monitoring Controlt 1 = Clogged Filter Switcht 2 = Fan Failure Switcht 3 = Discharge Air Sensing Tubet 4 = Clogged Filter Switch and Fan Fail Switcht 5 = Clogged Filter Switch and Discharge Air Sensing Tubet 6 = Fan Fail Switch and Discharge Air Sensing Tubet 7 = Clogged Filter and Fan Fail Switches and Discharge Air Sensing Tubet 8 = Novar Return Air Sensory
Explanation of Model Number Notes 1-17 follow. Unless otherwise noted, feature available for all W models, tonnages and phases.
1 Available for R-410A units only. 2 Standard on 4 ton , 3 phase Heat Pumps and 5 ton Heat Pumps. 3 Available for R-22 units only. 4 Not available with electromechanical controls. 5 Manual outside air damper will ship factory supplied within the unit, but must be field installed. 6 High pressure control is standard on all units. 7 Multispeed direct drive standard on 1 phase. Belt drive standard on 3 phase. 8 Economizer with Barometric Relief is for downflow configured units only. Order Economizer without Barometric Relief for horizontal configuration. Barometric Relief for horizontal configured units must be ordered as field installed accessory. 9 Through the base electric required when ordering disconnect/circuit breaker options. 0 Requires use of Disconnect or Circuit Breaker. q Standard metering devices are TXVs. w Frostat cannot be field installed in electro-mechanical units. e The return air smoke detector may not fit up or work properly on the Precedent units when used in conjunction with 3rd party accessories such as bolt on heat wheels, economizers and power exhaust. Do not order the return air smoke detectors when using this type of accessory. r Return air smoke detector cannot be ordered with Novar Controls. t These options are standard when ordering Novar Controls. y This option is used when ordering Novar Controls. u Not available with high temperature stat accessory.
Example: Model number WSC036E3RBA**C000A10001A1 describes a unit with the following characteristics: DX Cooling, 3 ton nominal cooling capacity, 208-230/60/3 power supply, ReliaTel controls, 6 kW electric heater model. 0-100% dry bulb economizer without barometric relief, standard belt drive motor, standard access panels/filters, standard condenser coil with no coil protection, through the base electric, non-fused disconnect, no convenience outlet or communications interface, standard refrigeration coil, high pressure control, return air smoke detector, and clogged filter switch.
PH 29
Power Supply 208-230/1/60 208-230/1/60 208-230/1/60 208-230/3/60 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60
Gross Capacity Cooling (BTUH) 38,100 50,800 63,100 38,100 50,800 63,100 38,100 50,800 63,100 38,100 50,800 63,100
SEER1 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0
PH 30
Tons 3 4 5
Tons 3 4 5
1 Economizer with Barometric Relief is for downflow configured units only. Order Economizer without Barometric Relief for horizontal configuration. Barometric relief for horizontal configured units must be ordered as field installed accessory BAYBARM010A. (Page PR-HP-11) 2 The Manual Outside Air Damper will ship factory supplied (field installed) within the unit. The option will no longer be factory installed.
Belt drive available for 3 phase 3-5 ton models only. Standard motor in 3-5 ton single phase models is direct drive.
3-4 tons have standard 1" throwaway filters. 5 ton have standard 2" throwaway filters.
PH 31
1 Disconnect/Circuit Breaker/Phase Monitor is available for 3 phase models only. 2 Must order Through the Base option when ordering disconnect or Breaker. 3 Phase Monitor is available with ReliaTel models only.
1 Powered Convenience Outlet Option is available for 3 phase models only. 2 Requires use of Disconnect or Circuit Breaker.
PH 32
1 Standard Refrigeration Metering Device - Thermal Expansion Valve (Outdoor & Indoor Coil).
1 High Pressure Control is standard on all units. 2 Crankcase heater is standard on WSC036E, 060E3,4,W.
1 Cannot be used with BAYFRST001A High Temperature Stat accessory. 2 The return air smoke detector may not fit up or work properly on the Precedent units when used in conjuntcion with 3rd party accessories
(such as bolt on heat wheels, economizers, and power exhaust). Do not order the return air smoke detectors when using this type of accessory.
PH 33
1 Combination of Discharge Air Sensing option, Economizer option and Tracer Summit or Tracker, Version 10 requires use of Tracer LCI-R Commu-
nications Interface. For jobs requiring true discharge air sensing with Tracer/Tracker COMM-3 or COMM-4, contact Clarksville Light Commercial Product Support.
PH 34
Accessory Electric Heaters: Unit with heater is single circuit / single point power entry
Model Power Number Supply BAYHTREW105A 208/230/1/60 BAYHTREW110A 208/230/1/60 BAYHTREW114A 208/230/1/60 BAYHTREW118A 208/230/1/60 BAYHTRE306A BAYHTRE312A BAYHTRE318A 208/240/3/60 208/240/3/60 208/240/3/60 KW Rating 3.8/5.0 7.5/10.0 10.4/13.8 13.2/17.6 4.5/6.0 9.0/12.0 13.0/17.4 Nominal No. of BTUH Stages 12,900/ 1 13,400 25,600/ 2 34,000 35,000/ 2 47,100 45,100 2 60,100 13,400/ 1 20,500 30,800/ 2 41,000 44,600/ 2 59,400 20,500 41,000 59,400 20,500 41,000 59,400 1 2 2 1 2 2 Used With WSC036-060E1 WSC036-060E1 WSC036-060E1 WSC048-060E1 WSC036-048E3 WSC036-048E3 WSC036-048E3
SH SH SH
20 20 20 20 20 20
Accessory Electric Heaters: Unit with heater is single circuit/single point power entry (5 Ton Only)
Model Number BAYHTRX105A BAYHTRX110A BAYHTRX114A BAYHTRX118A BAYHTRX306A BAYHTRX312A BAYHTRX318A BAYHTRX323A BAYHTRX406A BAYHTRX412A BAYHTRX418A BAYHTRX423A BAYHTRXW06A BAYHTRXW12A BAYHTRXW18A BAYHTRXW23A Power Supply 208/240/1/60 208/240/1/60 208/240/1/60 208/240/1/60 208/240/1/60 208/240/3/60 208/240/3/60 208/240/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 KW Rating 5.0 9.0 13.0 18.0 6.0 12.0 18.0 23.0 6.0 12.0 18.0 23.0 6.0 12.0 18.0 23.0 Nominal No. of BTUH Stages 13,400 1 30,800 2 44,600 2 59,400 2 20,500 41,000 59,400 78,500 20,500 41,000 59,400 78,500 20,500 41,000 59,400 78,500 1 2 2 2 1 2 2 2 1 2 2 2 Used With WSC060E1 WSC060E1 WSC060E1 WSC060E1 WSC060E3 WSC060E3 WSC060E3 WSC060E3 WSC060E4 WSC060E4 WSC060E4 WSC060E4 WSC060EW WSC060EW WSC060EW WSC060EW Mfg. Plant SH SH SH SH SH SH SH SH SH SH SH SH SH SH SH SH Shipping Weight 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28
PH 35
Accessories:
Model Number
BAYCURB042A1 BAYCURB043A1 BAYQACB009A1 BAYQACB010A1 BAYQACB011A1 BAYQACB012A1 BAYECON085A BAYECON087A BAYDMPR051A BAYDMPR054A BAYDMPR053B BAYDMPR056B BAYGARD036B BAYGARD040A BAYABRD001C BAYBARM010A7 BAYBARM011A7 BAYCO2K001B BAYCO2K003B BAYCCHT010B BAYCCHT011B BAYSTAT023 BAYSERV001A BAYSENS016A BAYFRST001A9 BAYENTH005A5 BAYENTH006B5 BAYDFPS003B8 BAYDFPS004A8 BAYTUBE005A68 BAYTUBE007A68 BAYICSI003A0 BAYLTCI002Bqw BAYLOAM020B8 BAYVNOR001B
Description
Roof Curb Roof Curb Quick Adapt Roof Curb24 Quick Adapt Roof Curb24 Quick Adapt Roof Curb34 Quick Adapt Roof Curb34 0-100% Economizer without Barometric Relief 0-100% Economizer without Barometric Relief 0-50% Motorized Outside Air Damper 0-50% Motorized Outside Air Damper 0-50% Manual Outside Air Damper 0-50% Manual Outside Air Damper Tool-less Condenser Coil Hail Guard Tool-less Condenser Coil Hail Guard ReliaTel Options Module Barometric Relief Barometric Relief CO2 Sensor Kit, Wall Mounted CO2 Sensor Kit, Duct Mounted Crankcase Heater Crankcase Heater Remote Potentiometer Selective Resistance Service Tester Temperature Sensor High Temperature Stat Reference Enthalpy Kit Comparative Enthalpy Kit Clogged Filter Switch Fan Failure Switch Discharge Air Sensing Kit Discharge Air Sensing Kit Comm-3/4 Trane Communications Interface LonTalk Communications Interface Evaporator Defrost Control (Frostat) Ventilation Override Kit
Used With
WSC036-048E WSC060E WSC036-048E2 WSC036-048E2 WSC060E3 WSC060E3 WSC036-048E WSC060E WSC036-048E WSC060E WSC036-048E WSC060E WSC036-048E WSC060E See Note8 WSC036-048E WSC0060E WSC036-060E W/Econ. or Motorized OA WSC036-060E W/Econ. or Motorized OA WSC036E3 WSC036E3,4,AW BAYECON085A,087A WSC036-060E WSC036-060E WSC036-060E BAYECON085A,087A BAYECON085A,087A WSC036-060E WSC036-060E WSC036-048E WSC060E WSC036-060E WSC036-060E
Shipping Weight
80 115 100 120 125 150 40 36 30 30 25 26 10 20 1 10 10 3 3.5 2 2 1 2 1 2 1 1 1 1 1 1 1 1 3 2.5
1 Lynn Haven manufacturing has a no return policy for this roof curb. 2 BAYQACB009A adapts Voyager BAYCURB021 roof curb to accept Precedent 3-4 ton unit. BAYQACB010A adapts Voyager BAYCURB022 roof curb to accept Precedent 3-4 ton unit. 3 BAYQACB011A adapts Voyager BAYCURB022B to accept Precedent 5 ton unit. BAYQACB012A adapts Voyager BAYCURB025 roof curb to accept Precedent 5 ton unit. 4 TCD036A, TCD048A, TCD060A, WCD036A, WCD048A, WCD060A are not Voyager units. These units were manufactured in Ft. Smith, AR and will not fit any Voyager curbs. 5 Kits contain all necessary parts to achieve desired level of enthalpy control.
6 Used for true discharge air sensing in both heating and cooling. Required for supply air tempering. 7 Barometric Relief accessory installs in ductwork for horizontal configuration. For downflow configuration, installs in the unit's horizontal return duct. See Installer's Guide for complete instructions. 8 BAYABRD001C is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS003A), Fan Fail Switch (BAYDFPS004A), Discharge Air Sensing Kit (BAYTUBE004A or BAYTUBE005A) or Evaporator Defrost Control (Frostat) (BAYLOAM020B) unless the following options are factory installed: Frostat, Smoke Detector, Clogged Filter Switch, Fan Failure Switch, Discharge Air Sensing Kit. These factory installed options include the ReliaTel Options Module.
9 Cannot be used in conjunction with factory installed smoke detector. 0 Interface allows unit to communicate with Tracer 100, Tracker, VariTrac II, and is the preferred methodof communication to Tracer Summit. q Interface allows unit to communicate as a Trane LonTalk device or directly with generic LonTalk Network BAS Controls. w For use with ReliaTel controlled units only.
PH 36
1 Used with Integrated ComfortTM Systems, any unit type. These sensors do not work with TCM. Consult BASD Marketing for them. 2 See Accessory IOM for operational characteristics. 3 Functional only with ReliaTel controls.
PH 37
Specifications: Downflow
Model Number WCD150B300G WCD150B30AG WCD150B30BG WCD150B30CG WCD150B30FG WCD150B30GG WCD150B400G WCD150B40AG WCD150B40BG WCD150B40CG WCD150B40FG WCD150B40GG WCD150BW00G WCD150BW0AG WCD150BW0BG WCD150BW0CG WCD150BW0FG WCD150BW0GG Factory Installed Option Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Power Supply 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 Capacity Cooling (BTUH) 153,200 153,200 153,200 153,200 153,200 153,200 153,200 153,200 153,200 153,200 153,200 153,200 153,200 153,200 153,200 153,200 153,200 153,200 EER 9.1 9.1 9.1 9.1 9.1 9.1 9.1 9.1 9.1 9.1 9.1 9.1 9.1 9.1 9.1 9.1 9.1 9.1 Uncrated Dimensions (in) H W L 50 71 107.5 50 71 107.5 50 71 107.5 50 71 107.5 50 71 107.5 50 71 107.5 50 50 50 50 50 50 50 50 50 50 50 50 71 71 71 71 71 71 71 71 71 71 71 71 107.5 107.5 107.5 107.5 107.5 107.5 107.5 107.5 107.5 107.5 107.5 107.5 Mfg. Shipping Plant Weight CK/001 1700 CK/001 1815 CK/001 1775 CK/001 1890 CK/001 1701 CK/001 1816 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 1700 1815 1775 1890 1701 1816 1700 1815 1775 1890 1701 1816
Features:
ReliaTel Controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field-installed Trane Communications Interface (TCI) Belt Drive Evaporator Fan Motor Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Capillary tube expansion device Liquid line drier Fork lift channels Operating charge of R-22 Trane-Tite-Top (T3) weather tight top and cabinet Trane built compressors Low pressure switches Dedicated horizontal and downflow designs Sloped sheet metal drain pan Single side access Single point power for electric heat Complete line of optional electric heaters Quick-access panels with handles Internally enhanced coil tubing Low ambient to 0 F standard Colored and numbered wiring UL listed and CSA certified 5 year compressor warranty Optional extended warranties
PH 38
Nominal No. of BTUH Stages 46,100/61,400 1 92,200/122,900 2 138,200/184,300 2 61,400 1 122,900 2 184,300 2 61,400 1 122,900 2 184,300 2
Used With WCH150B3 WCH150B3 WCH150B3 WCH150B4 WCH150B4 WCH150B4 WCH150BW WCH150BW WCH150BW
Nominal No. of BTUH Stages 46,100/61,400 1 92,200/122,900 2 138,200/184,300 2 61,400 1 122,900 2 184,300 2 61,400 1 122,900 2 184,300 2
Used With WCD150B3 WCD150B3 WCD150B3 WCD150B4 WCD150B4 WCD150B4 WCD150BW WCD150BW WCD150BW
Mfg. Shipping Plant Weight CK/001 28 CK/001 31 CK/001 38 CK/001 28 CK/001 31 CK/001 38 CK/001 28 CK/001 31 CK/001 38
PH 39
CK/001 115 CK/001 150 CK/001 50 CK/001 1 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 95 95 95 75 75 15 2 1 1 1 1 1 1
3
BAYTUBE008A4 BAYTUBE009A4
BAYVNOR002B
1 2 3 4 5 6 7
WCD150B WCH150B
1 1
2
For downflow use only. Cannot be adapted for horizontal units. Kits contain all necessary parts to achieve desired level of enthalpy control. High static drive and oversized motors are mutually exclusive. Do not combine. Used for true discharge air sensing in both heating and cooling models. Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B). Cannot be used with manual outside air damper. Clarksville Manufacturing has a no-return policy for this roof curb. BAYABRD002B is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS005A), Fan Fail Switch (BAYDFPS006A), Discharge Air Sensing Kit (BAYTUBE008A or BAYTUBE009A), Frostat (BAYLOAM023A), Ventilation Override (BAYVNOR002B). 8 Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B).
FOR CHOICE OF ZONE SENSORS (MICRO THERMOSTATS) SEE LAST PAGE OF THIS SECTION PH 40 Effective date: January 1, 2007
WCH180B400H WCH180B40BH Ov Motor WCH180B40FH TCI WCH180BW00H WCH180BW0BH Ov Motor WCH180BW0FH TCI
Specifications: Downflow
Model Number WCD180B300H WCD180B30AH WCD180B30BH WCD180B30CH WCD180B30FH WCD180B30GH WCD180B400H WCD180B40AH WCD180B40BH WCD180B40CH WCD180B40FH WCD180B40GH WCD180BW00H WCD180BW0AH WCD180BW0BH WCD180BW0CH WCD180BW0FH WCD180BW0GH Factory Installed Option Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Power Supply 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 Capacity Cooling (BTUH) 183,600 183,600 183,600 183,600 183,600 183,600 183,600 183,600 183,600 183,600 183,600 183,600 183,600 183,600 183,600 183,600 183,600 183,600 EER 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 Uncrated Dimensions (in) H W L 50 71 107.5 50 71 107.5 50 71 107.5 50 71 107.5 50 71 107.5 50 71 107.5 50 50 50 50 50 50 50 50 50 50 50 50 71 71 71 71 71 71 71 71 71 71 71 71 107.5 107.5 107.5 107.5 107.5 107.5 107.5 107.5 107.5 107.5 107.5 107.5 Mfg. Shipping Plant Weight CK/001 1750 CK/001 1865 CK/001 1825 CK/001 1940 CK/001 1751 CK/001 1866 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 1750 1865 1825 1940 1751 1866 1750 1865 1825 1940 1751 1866
Features:
ReliaTel Controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field-installed Trane Communications Interface (TCI) Belt drive evaporator fan motor Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Capillary tube expansion device Liquid line drier Fork lift channels Operating charge of R-22 Trane-Tite-Top (T3) weather tight top and cabinet Trane built compressors Low pressure switches Dedicated horizontal and downflow designs Sloped sheet metal drain pan Single side access Single point power for electric heat Complete line of optional electric heaters Quick-access panels with handles Internally enhanced coil tubing Low ambient to 0F standard Colored and numbered wiring UL listed and CSA certified 5 year compressor warranty Optional extended warranties
PH 41
Nominal No. of BTUH Stages 46,100/61,400 1 92,200/122,900 2 138,200/184,300 2 61,400 1 122,900 2 184,300 2 61,400 1 122,900 2 184,300 2
Nominal No. of BTUH Stages 46,100/61,400 1 92,200/122,900 2 138,200/184,300 2 61,400 1 122,900 2 184,300 2 61,400 1 122,900 2 184,300 2
Used With WCD180B3 WCD180B3 WCD180B3 WCD180B4 WCD180B4 WCD180B4 WCD180BW WCD180BW WCD180BW
Mfg. Shipping Plant Weight CK/001 28 CK/001 31 CK/001 38 CK/001 28 CK/001 31 CK/001 38 CK/001 28 CK/001 31 CK/001 38
PH 42
CK/001 115 CK/001 150 CK/001 50 CK/001 1 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 95 95 95 75 75 2 1 1 1 1 1 1
3
BAYTUBE008A4 BAYTUBE009A4
BAYVNOR002B
1 2 3 4 5 6 7
WCD180B WCH180B
CK/001 CK/001
1 1
2
For downflow use only. Cannot be adapted for horizontal units. Kits contain all necessary parts to achieve desired level of enthalpy control. Must be used with either field or factory installed TCI (Trane Communication Interface) Used for true discharge air sensing in both heating and cooling models. Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B). Cannot be used with manual outside air damper. Clarksville Manufacturing has a no-return policy for this roof curb. BAYABRD002B is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS005A), Fan Fail Switch (BAYDFPS006A), Discharge Air Sensing Kit (BAYTUBE008A or BAYTUBE009A), Frostat (BAYLOAM023A), Ventilation Override (BAYVNOR002B). 8 Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B).
FOR CHOICE OF ZONE SENSORS (MICRO THERMOSTATS) SEE LAST PAGE OF THIS SECTION PH 43 Effective date: January 1, 2007
Specifications: Downflow
Model Number WCD240B300G WCD240B30AG WCD240B30BG WCD240B30CG WCD240B30FG WCD240B30GG WCD240B400G WCD240B40AG WCD240B40BG WCD240B40CG WCD240B40FG WCD240B40GG WCD240BW00G WCD240BW0AG WCD240BW0BG WCD240BW0CG WCD240BW0FG WCD240BW0GG Factory Installed Option Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Economizer Ov Motor Econ/OvMtr TCI Econ/TCI Power Supply 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 Capacity Cooling (BTUH) 242,700 242,700 242,700 242,700 242,700 242,700 242,700 242,700 242,700 242,700 242,700 242,700 242,700 242,700 242,700 242,700 242,700 242,700 EER 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 8.6 Uncrated Dimensions (in) H W L 54 85 122.5 54 85 122.5 54 85 122.5 54 85 122.5 54 85 122.5 54 85 122.5 54 54 54 54 54 54 54 54 54 54 54 54 85 85 85 85 85 85 85 85 85 85 85 85 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 122.5 Mfg. Shipping Plant Weight CK/001 2340 CK/001 2475 CK/001 2520 CK/001 2565 CK/001 2341 CK/001 2476 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 2340 2475 2520 2565 2341 2476 2340 2475 2520 2565 2341 2476
Features:
ReliaTel Controls Built in anti-short cycle, time-delay relay and minimum on time controls ICS compatibility with either factory or field-installed Trane Communications Interface (TCI) Belt drive evaporator fan motor Quick-adjust idler arm assembly for belt and motor sheave adjustment 2" throwaway filters Capillary tube expansion device Liquid line drier Fork lift channels Operating charge of R-22 Trane-Tite-Top (T3) weather tight top and cabinet Trane built compressors Low pressure switches Dedicated horizontal and downflow designs Single side access Sloped sheet metal drain pan Single point power for electric heat Complete line of optional electric heaters Quick-access panels with handles Internally enhanced coil tubing Low ambient to 0F standard Colored and numbered wiring UL listed and CSA certified 1 year compressor warranty Optional extended warranties
PH 44
Nominal No. of BTUH Stages 92,200/122,900 2 138,200/184,300 2 184,300/245,700 2 122,900 2 184,300 2 245,700 2 122,900 2 184,300 2 245,700 2
Used With WCH240B3 WCH240B3 WCH240B3 WCH240B4 WCH240B4 WCH240B4 WCH240BW WCH240BW WCH240BW
Mfg. Shipping Plant Weight CK/001 27 CK/001 32 CK/001 34 CK/001 27 CK/001 32 CK/001 34 CK/001 27 CK/001 32 CK/001 34
Nominal No. of BTUH Stages 92,200/122,900 2 138,200/184,300 2 184,300/245,700 2 122,900 2 184,300 2 245,700 2 122,900 2 184,300 2 245,700 2
Used With WCD240B3 WCD240B3 WCD240B3 WCD240B4 WCD240B4 WCD240B4 WCD240BW WCD240BW WCD240BW
Mfg. Shipping Plant Weight CK/001 27 CK/001 32 CK/001 34 CK/001 27 CK/001 32 CK/001 34 CK/001 27 CK/001 32 CK/001 34
PH 45
BAYTUBE008A4 BAYTUBE009A4
BAYVNOR002B
1 2 3 4 5 6 7
WCD240B WCH240B
WC*240B w/ReliaTel Options Module
CK/001 CK/001
CK/001
1 1
2
For downflow use only. Cannot be adapted for horizontal units. Kits contain all necessary parts to achieve desired level of enthalpy control. Must be used with either field or factory installed TCI (Trane Communication Interface). Used for true discharge air sensing in both heating and cooling models. Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B). Cannot be used with manual outside air damper. Clarksville Manufacturing has a no-return policy for this roof curb. BAYABRD002B is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS005A), Fan Fail Switch (BAYDFPS006A), Discharge Air Sensing Kit (BAYTUBE008A or BAYTUBE009A), Frostat (BAYLOAM023A), Ventilation Override (BAYVNOR002B). 8 Functional only with ReliaTel Options Module (BAYABRD002B/FIYABRD002B).
FOR CHOICE OF ZONE SENSORS (MICRO THERMOSTATS) SEE LAST PAGE OF THIS SECTION PH 46 Effective date: January 1, 2007
12-1/2 20 Ton
BAYSENS013C1 BAYSENS014C1 BAYSENS019C BAYSENS017B BAYSENS031A3 BAYSENS032A3 BAYMTPL003B BAYMTPL004B BAYSTAT050A BAYSTAT052A BAYSTAT053A
WC*150-240 WC*150-240 WC*150-240 BAYSENS007B,009B, 011B,019C WC*150-240 WC*150-240 BAYSENS019C BAYSENS007,009,011 017B & 013,014C WC*150-240 WC*150-240
CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001 CK/001
1 1 1 1 1 1 1 1 1 1 1
WC*150-240 CK/001 (with Dehumidification Option) WC*150-240 CK/001 BAYSTAT050A, 052A,053A CK/001 BAYSTAT050A, 052A,053A CK/001
1 1 1
Used with Integrated Comfort SystemsTM any unit type. These sensors do not work with TCM. Consult BASD Marketing for them. See Accessory IOM for operational characteristics. Functional only with ReliaTel controls. Either horizontal or downflow models.
Controls:
Model Number BAYCO2K002B BAYCO2K004B BAYICSI004B BAYLTCI003B Description CO2 Sensor Kit, Wall Mounted CO2 Sensor Kit, Duct Mounted Field Installed TCI (Trane Communication Interface) LonTalk Interface Used with WC*150-240 w/Economizer WC*150-240 w/Economizer WC*150-240 WC*150-240 Mfg. Plant CK/001 CK/001 CK/001 CK/001 Shipping Weight 3 3.5 1 1
PH 47
Complete systems installed in Residential Applications ........................................... WA-2-WA-3 Condensing units installed in Residential Applications .......................................................WA-4 Compressors installed in Residential Applications ..............................................................WA-5 Furnaces, air handlers and heat exchangers installed in Residential Applications .................................................................................................. WA-6 Complete systems installed in Commercial Applications ....................................... WA-7 - WA-8 Condensing units installed in Commercial Applications ......................................................WA-9 Compressor installed in Commercial Applications ............................................................WA-10 Furnaces, air handlers and heat exchangers installed in Commercial Applications ................................................................................ WA-11 - WA-12 Accessories installed in Residential or Commercial Application .......................................WA-13 National Account ...............................................................................................................WA-14 Water Source package systems installed in Residential Applications ..............................WA-15 Water Source package systems installed in Commercial Applications .............................WA-16 No Parts Mark-up Warranties installed in Residential or Commercial Applications ..........WA-17 General Notes ...................................................................................................................WA-18 Numerical listing of product coverage ................................................................ WA-19 - WA-53 Optional Extended Warranty Benefits .................................................................. WA-54-WA-55
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2007 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 1
These Optional Extended Warranties apply to complete systems when installed in Residential Applications. Coverage includes Trane condensing unit, thermostat, and air handler or furnace with evaporator coil if identified on the Agreement. One (1) -year warranties apply to equipment less than five (5) years old and can be renewed each year until the equipment is ten (10) years old when accepted by the Extended Warranty department. Five (5) -year and ten (10) -year warranties expire five (5) or ten (10) years from the installation date of the covered equipment no matter when purchased. Equipment installed within 1 mile of salt water or environment with high sulfur content should use the S warranty models. The Warranty would be the same as below with an S in the 7th digit instead of the 0 below. For example, use TAYWARS004 instead of TAYWAR0004. Condensing unit determines type of system for Extended Warranty Coverage. * Equipment with ten (10) year limited warranty on all parts.
1-5
TAYWAR4204
1-5
TAYWAR01231 TAYWAR0124
1-5 1-5
DESCRIPTION PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM, RESIDENTIAL APPLICATION, WITH NON-TRANE EVAPORATOR COIL PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM, RESIDENTIAL APPLICATION, WITH NON-TRANE EVAPORATOR COIL PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM INCLUDES TRANE ELECTRONIC AIR CLEANER PACKAGE OR SPLIT SYSTEM, RESIDENTIAL APPLICATION, WITH NON-TRANE EVAPORATOR COIL PACKAGE OR SPLIT SYSTEM, RESIDENTIAL APPLICATION COMFORT SYSTEM, WITH NON-TRANE EVAPORATOR COIL *XL - SPLIT SYSTEM *XL - SPLIT SYSTEM *XL - SPLIT SYSTEM, RESIDENTIAL APPLICATION, WITH NON-TRANE EVAPORATOR COIL *XL - SPLIT SYSTEM *XL - SPLIT SYSTEM
TERM 1 YR 1 YR 1 YR
5 YR 5 YR 5 YR 5 YR
PARTS ONLY PARTS & LABOR PARTS & LABOR PARTS & LABOR
10 YR 10 YR 10 YR 10 YR 10 YR
PARTS ONLY PARTS & LABOR PARTS & LABOR PARTS & LABOR PARTS & LABOR
10 YR
10 YR
1 YR 1 YR 1 YR
5 YR 5 YR
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2005 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 2
5 YR 10 YR 10 YR 5 YR
PARTS & LABOR PARTS & LABOR PARTS & LABOR PARTS & LABOR
TAYWAR0407
1-5
10 YR
TAYWAR0408
1-5
5 YR
TAYWAR0409
1-5
10 YR
TAYWAR0410
1-5
10 YR
TAYWAR0411
1-5
10 YR
10 YR 10 YR 10 YR
1-5
10 YR
1-5
10 YR
1 YR 1 YR 1 YR 5 YR 10 YR 1 YR 5 YR 10 YR
PARTS ONLY PARTS & LABOR PARTS & LABOR PARTS & LABOR PARTS & LABOR PARTS & LABOR PARTS & LABOR PARTS & LABOR
Obsolete for Equipment with five (5) or ten (10) year Limited Warranty on all Functional Parts. All XB units and M Package Units are not eligible if installed or initial warranty sale date is after 10/01/2001.
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2007 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 3
These Optional Extended Warranties apply to Trane condensing units only when installed in Residential Applications. A new Trane evaporator coil and thermostat are covered only if installed at the same time and identified on the warranty Agreement. Compressor only warranties cover only the compressor. One (1) -year warranties apply to equipment less than five (5) years old and can be renewed each year until the equipment is ten (10) years old when accepted by the Extended Warranty Department. Five (5)- and ten (10) -year warranties expire five (5) or ten (10) years from the installation date of the covered equipment no matter when purchased. Equipment installed within 1 mile of salt water or environment with high sulfur content should use the S warranty models. The Warranty would be the same as below with an S in the 7th digit instead of the 0 below. For example, use TAYWARS002 instead of TAYWAR0002. * Equipment with ten (10) year limited warranty on functional parts. TONS 1-5 1-5 1-5 DESCRIPTION CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT AND THERMOSTAT, RESIDENTIAL APPLICATION, WITH NON-TRANE EVAPORATOR COIL CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT AND THERMOSTAT, RESIDENTIAL APPLICATION, WITH NON-TRANE EVAPORATOR COIL CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT AND THERMOSTAT, RESIDENTIAL APPLICATION, WITH NON-TRANE EVAPORATOR COIL *XL - CONDENSING UNIT *XL - CONDENSING UNIT *XL CONDENSING UNIT AND THERMOSTAT, RESIDENTIAL APPLICATION, WITH NON-TRANE EVAPORATOR COIL *XL - CONDENSING UNIT *XL - CONDENSING UNIT *XL CONDENSING UNIT AND THERMOSTAT, RESIDENTIAL APPLICATION, WITH NON-TRANE EVAPORATOR COIL *XL - CONDENSING UNIT *XL - CONDENSING UNIT *XL, CONDENSING UNIT AND THERMOSTAT, RESIDENTIAL APPLICATION, WITH NON-TRANE EVAPORATOR COIL XV - CONDENSING UNIT XV - CONDENSING UNIT TERM 1 YR 1 YR 1 YR COVERAGE PARTS ONLY PARTS & LABOR PARTS & LABOR
5 YR 5 YR 5 YR
10 YR 10 YR 10 YR
1 YR 1 YR 1 YR
5 YR 5 YR 5 YR
10 YR 10 YR 10 YR
TAYWAR0131 TAYWAR0132
1-5 1-5
1 YR 1 YR
Obsolete for Equipment with five (5) or ten (10) year Limited Warranty on all Functional Parts. All XB units and M Package Units are not eligible if installed or initial warranty sale date is after 10/01/2001.
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2005 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 4
Obsolete for models with a ten (10) year Limited Warranty on the Compressor All XB units and M Package Units are not eligible if installed or initial warranty sale date is after 10/01/2001.
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2007 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 5
These Optional Extended Warranties apply to Trane furnaces, air handlers and heat exchangers when installed in Residential Applications. A new Trane evaporator coil and thermostat are covered only if installed at the same time or air handler and identified on the Agreement. Heat Exchanger warranties cover only the Heat Exchanger. One (1) -year warranties apply to equipment less than five (5) years old and can be renewed each year until the equipment is ten (10) years old when accepted by the Extended Warranty Department. Five (5)- through twenty (20) -year warranties expire five (5) through twenty (20) years from the installation date of the covered equipment no matter when purchased. Equipment installed within 1 mile of salt water or environment with high sulfur content should use the S warranty models. The Warranty would be the same as below with an S in the 7th digit instead of the 0 below. For example, use TAYWARS011 instead of TAYWAR0011. WARRANTY # TAYWAR0232 TAYWAR0273 TAYWAR0047 TAYWAR0274 TAYWAR00911 TAYWAR02751 TAYWAR0011 TAYWAR0276 TAYWAR0402 TAYWAR0403 TAYWAR00922 TAYWAR02772 TAYWAR00122 TAYWAR02782 TAYWAR0404 TAYWAR0405 TAYWAR01372 TAYWAR02882 TAYWAR0013 2 TAYWAR4086 2 TAYWAR0289 2 TAYWAR40872 TAYWAR0331 TAYWAR0138 TAYWAR0034 TAYWAR0139 TAYWAR0108 TONS 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 DESCRIPTION FURNACE OR AIR HANDLER VARIABLE SPEED FURNACE OR AIR HANDLER FURNACE OR AIR HANDLER VARIABLE SPEED FURNACE OR AIR HANDLER FURNACE OR AIR HANDLER VARIABLE SPEED FURNACE OR AIR HANDLER FURNACE OR AIR HANDLER VARIABLE SPEED FURNACE OR AIR HANDLER FURNACE OR AIR HANDLER VARIABLE SPEED FURNACE OR AIR HANDLER FURNACE OR AIR HANDLER VARIABLE SPEED FURNACE OR AIR HANDLER FURNACE OR AIR HANDLER VARIABLE SPEED FURNACE OR AIR HANDLER FURNACE OR AIR HANDLER VARIABLE SPEED FURNACE FURNACE OR AIR HANDLER VARIABLE SPEED FURNACE OR AIR HANDLER FURNACE OR AIR HANDLER FURNACE OR AIR HANDLER VARIABLE SPEED FURNACE OR AIR HANDLER VARIABLE SPEED FURNACE OR AIR HANDLER HEAT EXCHANGER HEAT EXCHANGER HEAT EXCHANGER HEAT EXCHANGER HEAT EXCHANGER TERM 1 YR 1 YR 1 YR 1 YR 5 YR 5 YR 5 YR 5 YR 5 YR 5 YR 10 YR 10 YR 10 YR 10 YR 10 YR 10 YR 15 YR 15 YR 15 YR 11-15 YR 15 YR 11-15 YR 10 YR 10 YR 15 YR 15 YR 20 YR COVERAGE PARTS ONLY PARTS ONLY PARTS & LABOR PARTS & LABOR PARTS ONLY PARTS ONLY PARTS & LABOR PARTS & LABOR PARTS & LABOR PARTS & LABOR PARTS ONLY PARTS ONLY PARTS & LABOR PARTS & LABOR PARTS & LABOR PARTS & LABOR PARTS ONLY PARTS ONLY PARTS & LABOR PARTS & LABOR PARTS & LABOR PARTS & LABOR LABOR ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY
Obsolete for Equipment with five (5) year Limited Warranty on all Functional Parts. TUE/TDE furnaces and TVF, TWG air handlers are not eligible if installed or initial warranty sale date is after 10/01/2001.
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2005 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 6
These Optional Extended Warranties apply to complete systems when installed in Commercial Applications. Coverage includes Trane condensing unit, thermostat and air handler or furnace with evaporator coil if identified on the Agreement. One (1) -year warranties apply to equipment less than five (5) years old and can be renewed each year until the equipment is ten (10) years old when accepted by the Extended Warranty Department. Five (5)- and ten (10) -year warranties expire five (5) or ten (10) years from the installation date of the covered equipment no matter when purchased. Equipment installed within 1 mile of salt water or environment with high sulfur content should use the S warranty models. The Warranty would be the same as below with an S in the 7th digit instead of the 0 below. For example, use TAYWARS146 instead of TAYWAR0146. WARRANTY # TAYWAR0141 TAYWAR0142 TAYWAR0143 TAYWAR0144 TAYWAR01451 TAYWAR01461 TAYWAR0153 TAYWAR0154 TAYWAR0325 TAYWAR0326 TAYWAR0327 TAYWAR0159 TAYWAR0052 TAYWAR0095 TAYWAR0016 TAYWAR4003 TAYWAR4093 TAYWAR0160 TAYWAR0058 TAYWAR0101 TAYWAR0022 TAYWAR4004 TAYWAR4094 TAYWAR0161 TAYWAR0053 TAYWAR0096 TAYWAR0017 TAYWAR4057 TAYWAR4095 TAYWAR0162 TAYWAR0059 TAYWAR0102 TAYWAR0023 TAYWAR4060 TAYWAR4096 TONS 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 3-6 3-6 3-6 6.25-7.50 6.25-7.50 6.25-7.50 6.25-7.50 6.25-7.50 6.25-7.50 6.25-7.50 6.25-7.50 6.25-7.50 6.25-7.50 6.25-7.50 6.25-7.50 8.50-10 8.50-10 8.50-10 8.50-10 8.50-10 8.50-10 8.50-10 8.50-10 8.50-10 8.50-10 8.50-10 8.50-10 DESCRIPTION PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM XV - PACKAGE OR SPLIT SYSTEM XV - PACKAGE OR SPLIT SYSTEM + II - SPLIT SYSTEM + II - SPLIT SYSTEM + II - SPLIT SYSTEM PACKAGE UNIT PACKAGE UNIT PACKAGE UNIT PACKAGE UNIT PACKAGE UNIT PACKAGE UNIT + ECONOMIZER SPLIT SYSTEM SPLIT SYSTEM SPLIT SYSTEM SPLIT SYSTEM SPLIT SYSTEM SPLIT SYSTEM + ECONOMIZER PACKAGE UNIT PACKAGE UNIT PACKAGE UNIT PACKAGE UNIT PACKAGE UNIT PACKAGE UNIT + ECONOMIZER SPLIT SYSTEM SPLIT SYSTEM SPLIT SYSTEM SPLIT SYSTEM SPLIT SYSTEM SPLIT SYSTEM + ECONOMIZER TERM 1 YR 1 YR 5 YR 5 YR 10 YR 10 YR 1 YR 1 YR 1 YR 5 YR 10 YR 1 YR 1 YR 5 YR 5 YR 10 YR 10 YR 1 YR 1 YR 5 YR 5 YR 10 YR 10 YR 1 YR 1 YR 5 YR 5 YR 10 YR 10 YR 1 YR 1 YR 5 YR 5 YR 10 YR 10 YR COVERAGE PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS & LABOR PARTS & LABOR PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS & LABOR PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS & LABOR PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS & LABOR PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS & LABOR PARTS & LABOR
All XB units are not eligible if installed or initial warranty sale date is after 10/01/2001.
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2007 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 7
These Optional Extended Warranties apply to complete systems when installed in Commercial Applications. Coverage includes Trane condensing unit, thermostat and air handler or furnace with evaporator coil and identified on the Agreement. One (1) -year warranties apply to equipment less than five (5) years old and can be renewed each year until the equipment is ten (10) years old when accepted by the Extended Warranty Department. Five (5)- and ten (10) -year warranties expire five (5) or ten (10) years from the installation date of the covered equipment no matter when purchased. Equipment installed within 1 mile of salt water or environment with high sulfur content should use the S warranty models. The Warranty would be the same as below with an S in the 7th digit instead of the 0 below. For example, use TAYWARS163 instead of TAYWAR0163. WARRANTY # TAYWAR0163 TAYWAR0054 TAYWAR0097 TAYWAR0018 TAYWAR4058 TAYWAR4148 TAYWAR0164 TAYWAR0060 TAYWAR0103 TAYWAR0024 TAYWAR4098 TAYWAR0165 TAYWAR0055 TAYWAR0098 TAYWAR0019 TAYWAR4059 TAYWAR4124 TAYWAR0166 TAYWAR0061 TAYWAR0104 TAYWAR0025 TAYWAR4099 TAYWAR0167 TAYWAR0056 TAYWAR0099 TAYWAR0020 TAYWAR4082 TAYWAR0168 TAYWAR0062 TAYWAR0105 TAYWAR0026 TAYWAR4100 TAYWAR0169 TAYWAR0057 TAYWAR0100 TAYWAR0021 TAYWAR4083 TONS 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 15 - 17.50 15 - 17.50 15 - 17.50 15 - 17.50 15 - 17.50 15 - 17.50 15 - 17.50 15 - 17.50 15 - 17.50 15 - 17.50 15 - 17.50 20 20 20 20 20 20 20 20 20 20 25 25 25 25 25 DESCRIPTION PACKAGE UNIT PACKAGE UNIT PACKAGE UNIT PACKAGE UNIT PACKAGE UNIT PACKAGE UNIT + ECONOMIZER SPLIT SYSTEM SPLIT SYSTEM SPLIT SYSTEM SPLIT SYSTEM SPLIT SYSTEM PACKAGE UNIT PACKAGE UNIT PACKAGE UNIT PACKAGE UNIT PACKAGE UNIT PACKAGE UNIT + ECONOMIZER SPLIT SYSTEM SPLIT SYSTEM SPLIT SYSTEM SPLIT SYSTEM SPLIT SYSTEM PACKAGE UNIT PACKAGE UNIT PACKAGE UNIT PACKAGE UNIT PACKAGE UNIT SPLIT SYSTEM SPLIT SYSTEM SPLIT SYSTEM SPLIT SYSTEM SPLIT SYSTEM PACKAGE UNIT PACKAGE UNIT PACKAGE UNIT PACKAGE UNIT PACKAGE UNIT TERM 1 YR 1 YR 5 YR 5 YR 10 YR 10 YR 1 YR 1 YR 5 YR 5 YR 10 YR 1 YR 1 YR 5 YR 5 YR 10 YR 10 YR 1 YR 1 YR 5 YR 5 YR 10 YR 1 YR 1 YR 5 YR 5 YR 10 YR 1 YR 1 YR 5 YR 5 YR 10 YR 1 YR 1 YR 5 YR 5 YR 10 YR COVERAGE PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS & LABOR PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS & LABOR PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS & LABOR
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2005 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 8
These Optional Extended Warranties apply to condensing units only when installed in Commercial Applications. Coverage includes a new Trane evaporator coil and thermostat only if installed at the same time and identified on the Agreement. One (1) -year warranties apply to equipment less than five (5) years old and can be renewed each year until the equipment is ten (10) years old when accepted by the Extended Warranty Department. Five (5)- and ten (10) -year warranties expire five (5) or ten (10) years from the installation date of the covered equipment no matter when purchased. Equipment installed within 1 mile of salt water or environment with high sulfur content should use the S warranty models. The Warranty would be the same as below with an S in the 7th digit instead of the 0 below. For example, use TAYWARS170 instead of TAYWAR0170. WARRANTY # TAYWAR0170 TAYWAR0171 TAYWAR0172 TAYWAR0173 TAYWAR01741 TAYWAR01751 TAYWAR0182 TAYWAR0183 TAYWAR0188 TAYWAR0189 TAYWAR0190 TAYWAR0191 TAYWAR4072 TAYWAR0192 TAYWAR0193 TAYWAR0194 TAYWAR0195 TAYWAR4107 TAYWAR0196 TAYWAR0197 TAYWAR0198 TAYWAR0199 TAYWAR4108 TAYWAR0200 TAYWAR0201 TAYWAR0202 TAYWAR0203 TAYWAR4109 TAYWAR0204 TAYWAR0205 TAYWAR0207 TAYWAR0257 TAYWAR4110 TONS 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 6.25 - 7.50 6.25 - 7.50 6.25 - 7.50 6.25 - 7.50 6.25 - 7.50 8.50 - 10 8.50 - 10 8.50 - 10 8.50 - 10 8.50 - 10 12.50 12.50 12.50 12.50 12.50 15 - 17.50 15 - 17.50 15 - 17.50 15 - 17.50 15 - 17.50 20 20 20 20 20 DESCRIPTION CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT XV - CONDENSING UNIT XV - CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT TERM 1 YR 1 YR 5 YR 5 YR 10 YR 10 YR 1 YR 1 YR 1 YR 1 YR 5 YR 5 YR 10 YR 1 YR 1 YR 5 YR 5 YR 10 YR 1 YR 1 YR 5 YR 5 YR 10 YR 1 YR 1 YR 5 YR 5 YR 10 YR 1 YR 1 YR 5 YR 5 YR 10 YR COVERAGE PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS & LABOR
All XB Units are not eligible if installed or initial warranty sale date is after 10/01/2001
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2007 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 9
These Optional Extended Warranties apply to compressors in Trane equipment when installed in Commercial Applications. One (1) -year warranties apply to equipment less than five (5) years old and can be renewed each year until the equipment is ten (10) years old when accepted by the Extended Warranty Department. Five (5)- and ten (10) -year warranties expire five (5) or ten (10) years from the installation date of the covered equipment no matter when purchased. Equipment installed within 1 mile of salt water or environment with high sulfur content should use the S warranty models. The Warranty would be the same as below with an S in the 7th digit instead of the 0 below. For example, use TAYWARS208 instead of TAYWAR0208. WARRANTY # TONS TAYWAR0208 1-5 TAYWAR0209 1-5 TAYWAR0210 1-5 TAYWAR0256 1-5 TAYWAR021112 1-5 TAYWAR021212 1-5 TAYWAR021312 1-5 TAYWAR0214 6.25 - 7.50 TAYWAR0215 6.25 - 7.50 TAYWAR0216 6.25 - 7.50 TAYWAR4071 6.25 - 7.50 TAYWAR0217 8.50 - 10 TAYWAR0218 8.50 - 10 TAYWAR0219 8.50 - 10 TAYWAR4039 8.50 -10 TAYWAR0220 12.50 TAYWAR0221 12.50 TAYWAR0222 12.50 TAYWAR4040 12.50 TAYWAR0223 15 - 17.50 TAYWAR0224 15 - 17.50 TAYWAR0225 15 - 17.50 TAYWAR4041 15 - 25 TAYWAR0226 20 TAYWAR0227 20 TAYWAR0030 20 TAYWAR0228 20 TAYWAR0229 25 TAYWAR0230 25 TAYWAR0031 25 TAYWAR0231 25 DESCRIPTION COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY TERM 1 YR 1 YR 1 YR 5 YR 10 YR 10 YR 10 YR 1 YR 1 YR 5 YR 10 YR 1 YR 1 YR 5 YR 10 YR 1 YR 1 YR 5 YR 10 YR 1 YR 1 YR 5 YR 10 YR 1 YR 1 YR 5 YR 5 YR 1 YR 1 YR 5 YR 5 YR COVERAGE PARTS ONLY LABOR ONLY PARTS & LABOR LABOR ONLY PARTS ONLY LABOR ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR LABOR ONLY PARTS ONLY PARTS ONLY PARTS & LABOR LABOR ONLY PARTS ONLY PARTS ONLY PARTS & LABOR LABOR ONLY PARTS ONLY PARTS ONLY PARTS & LABOR LABOR ONLY PARTS ONLY PARTS ONLY PARTS & LABOR PARTS ONLY LABOR ONLY PARTS ONLY PARTS & LABOR PARTS ONLY LABOR ONLY
Obsolete for Trane accessories installed or initial warranty sale date is after 10/01/02. All XB units and M Package Units are not eligible if installed or initial warranty sale date is after 10/01/2001.
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2005 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 10
These Optional Extended Warranties apply to Trane furnaces, air handlers and heat exchangers when installed in Commercial Applications. A new Trane evaporator coil and thermostat are covered only if installed at the same time and identified on the Agreement. Heat Exchanger warranties cover only the Heat Exchanger. One (1) -year warranties apply to equipment less than five (5) years old and can be renewed each year until the equipment is ten (10) years old when accepted by the Extended Warranty Department. Five (5)- through twenty -(20) year warranties expire five (5) through twenty (20) years from the installation of the covered equipment no matter when purchased. Equipment installed within 1 mile of salt water or environment with high sulfur content should use the S warranty models. The Warranty would be the same as below with an S in the 7th digit instead of the 0 below. For example, use TAYWARS233 instead of TAYWAR0233. WARRANTY # TAYWAR0233 TAYWAR0279 TAYWAR0234 TAYWAR0280 TAYWAR0235 TAYWAR0281 TAYWAR0236 TAYWAR0282 TAYWAR02371 TAYWAR02831 TAYWAR02381 TAYWAR02841 TAYWAR02391 TAYWAR02901 TAYWAR02401 TAYWAR02911 TAYWAR0241 TAYWAR0334 TAYWAR0242 TAYWAR0243 TAYWAR0244 TAYWAR0245 TAYWAR0035 TAYWAR0247 TAYWAR0036 TAYWAR0248 TONS 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 6.25 - 12.50 6.25 - 12.50 6.25 - 12.50 6.25 - 12.50 DESCRIPTION FURNACE OR AIR HANDLER VARIABLE SPEED FURNACE OR AIR HANDLER FURNACE OR AIR HANDLER VARIABLE SPEED FURNACE OR AIR HANDLER FURNACE OR AIR HANDLER VARIABLE SPEED FURNACE OR AIR HANDLER FURNACE OR AIR HANDLER VARIABLE SPEED FURNACE OR AIR HANDLER FURNACE OR AIR HANDLER VARIABLE SPEED FURNACE OR AIR HANDLER FURNACE OR AIR HANDLER VARIABLE SPEED FURNACE OR AIR HANDLER FURNACE OR AIR HANDLER VARIABLE SPEED FURNACE OR AIR HANDLER FURNACE OR AIR HANDLER VARIABLE SPEED FURNACE OR AIR HANDLER HEAT EXCHANGER HEAT EXCHANGER HEAT EXCHANGER HEAT EXCHANGER HEAT EXCHANGER HEAT EXCHANGER HEAT EXCHANGER HEAT EXCHANGER HEAT EXCHANGER HEAT EXCHANGER TERM 1 YR 1 YR 1 YR 1 YR 5 YR 5 YR 5 YR 5 YR 10 YR 10 YR 10 YR 10 YR 15 YR 15 YR 15 YR 15 YR 10 YR 10 YR 10 YR 15 YR 15 YR 20 YR 10 YR 10 YR 15 YR 15 YR COVERAGE PARTS ONLY PARTS ONLY PARTS & LABOR PARTS & LABOR PARTS ONLY PARTS ONLY PARTS & LABOR PARTS & LABOR PARTS ONLY PARTS ONLY PARTS & LABOR PARTS & LABOR PARTS ONLY PARTS ONLY PARTS & LABOR PARTS & LABOR PARTS ONLY LABOR ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR
TUE/TDE furnaces and TVF, TWG air handlers are not eligible if installed or initial warranty sale date is after 10/01/2001.
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2007 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 11
These Optional Extended Warranties apply to furnaces, air handlers and heat exchangers when installed in Commercial Applications. A new Trane evaporator coil and thermostat are covered only if installed at the same time and identified on the Agreement. Heat Exchanger warranties cover only the Heat Exchanger. One (1) -year warranties apply to equipment less than five (5) years old and can be renewed each year until the equipment is ten (10) years old when accepted by the Extended Warranty Department. Five (5)- through twenty (20) -year warranties expire five (5) through twenty (20) years from the installation date of the covered equipment no matter when purchased. Equipment installed within 1 mile of salt water or environment with high sulfur content should use the S warranty models. The Warranty would be the same as below with an S in the 7th digit instead of the 0 below. For example, use TAYWARS269 instead of TAYWAR0269. WARRANTY # TAYWAR0269 TAYWAR0270 TAYWAR0271 TAYWAR0272 TAYWAR0037 TAYWAR0249 TAYWAR0038 TAYWAR0250 TAYWAR0039 TAYWAR0251 TAYWAR0040 TAYWAR0252 TAYWAR0041 TAYWAR0253 TAYWAR0042 TAYWAR0254 TONS 6.25 - 20 6.25 - 20 6.25 - 20 6.25 - 20 15 - 17.50 15 - 17.50 15 - 17.50 15 - 17.50 20 20 20 20 25 25 25 25 DESCRIPTION AIR HANDLER AIR HANDLER AIR HANDLER AIR HANDLER HEAT EXCHANGER HEAT EXCHANGER HEAT EXCHANGER HEAT EXCHANGER HEAT EXCHANGER HEAT EXCHANGER HEAT EXCHANGER HEAT EXCHANGER HEAT EXCHANGER HEAT EXCHANGER HEAT EXCHANGER HEAT EXCHANGER TERM 1 YR 1 YR 5 YR 5 YR 10 YR 10 YR 15 YR 15 YR 5 YR 5 YR 10 YR 10 YR 5 YR 5 YR 10 YR 10 YR COVERAGE PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2005 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 12
These Optional Extended Warranties apply to accessories that are installed in Residential or Commercial Applications. One (1) -year warranties apply to equipment less than five (5) years old and can be renewed each year until the equipment is ten (10) years old when accepted by the Extended Warranty Department. Five (5)- through (15) -year warranties expire five (5) through fifteen (15) years from the installation date of the covered equipment no matter when purchased. Equipment installed within 1 mile of salt water or environment with high sulfur content should use the S warranty models. The Warranty would be the same as below with an S in the 7th digit instead of the 0 below. For example, use TAYWARS048 instead of TAYWAR0048. WARRANTY # TAYWAR0048 TAYWAR00931 TAYWAR0014 TAYWAR0094 TAYWAR0015 TAYWAR00763 TAYWAR00773 TAYWAR00783 TAYWAR02933 TAYWAR02943 TAYWAR02953 TAYWAR02963 TAYWAR02853 TAYWAR01093 TAYWAR0080 TAYWAR0079 TAYWAR0043 TAYWAR02864 TAYWAR01074 TAYWAR00324 TAYWAR40614 TAYWAR02603 TAYWAR02613 TAYWAR02621 TAYWAR0263 3 TAYWAR026423 TAYWAR0265 23 TAYWAR0267 TAYWAR0268 TONS ALL ALL ALL ALL ALL 1-5 1-5 1-5 1-25 1-25 1-5 1-5 6-25 6-25 1-5 1-5 3-25 5-25 5-25 5-25 3-25 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 DESCRIPTION TRANE ELECTRONIC AIR CLEANER TRANE ELECTRONIC AIR CLEANER TRANE ELECTRONIC AIR CLEANER TRANE ELECTRONIC AIR CLEANER TRANE ELECTRONIC AIR CLEANER PROGRAMMABLE THERMOSTAT PROGRAMMABLE THERMOSTAT PROGRAMMABLE THERMOSTAT NON-PROGRAMMABLE THERMOSTAT NON-PROGRAMMABLE THERMOSTAT NON-PROGRAMMABLE THERMOSTAT NON-PROGRAMMABLE THERMOSTAT PROGRAMMABLE THERMOSTAT PROGRAMMABLE THERMOSTAT HOT WATER BANK (ECU ONLY) HOT WATER BANK (ECU ONLY) UNITARY CONTROL PROCESSOR ECONOMIZER ECONOMIZER ECONOMIZER ECONOMIZER EVAPORATOR COIL EVAPORATOR COIL EVAPORATOR COIL EVAPORATOR COIL EVAPORATOR COIL EVAPORATOR COIL INTEGRATED ZONE SYSTEM INTEGRATED ZONE SYSTEM TERM 1 YR 5 YR 5 YR 10 YR 10 YR 1 YR 5 YR 10 YR 1 YR 5 YR 10 YR 15 YR 1 YR 5 YR 1 YR 5 YR 5 YR 1 YR 5 YR 5 YR 10 YR 1 YR 1 YR 5 YR 5 YR 10 YR 10 YR 5 YR 10 YR COVERAGE PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS & LABOR PARTS & LABOR PARTS & LABOR PARTS & LABOR PARTS & LABOR PARTS & LABOR PARTS & LABOR PARTS & LABOR PARTS & LABOR PARTS & LABOR PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS & LABOR PARTS & LABOR
Obsolete for Trane accessories installed or initial warranty sale date is after 10/01/2001. Not available on CCB/CUB coils if installed or initial warranty sale date is after 10/01/2001. Can be used to cover 3rd party equipment if installed with Trane equipment. In addition to the system extended warranty coverage, all factory installed economizers in 5-25 ton equipment must have separate extended warranty coverage.
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2007 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 13
These Optional Extended Warranties provides labor coverage from installation/startup on covered repairs. Warranties must be purchased at the time of the equipment installation. A National Account is defined as a major purchaser of Trane equipment whose distribution activities extend into the primary sales area of more than one center or distributor. Although primarily intended for National Accounts, these Extended Warranties may be purchased by any dealer desiring the coverage provided by them. Note: TAYWAR0363 - 0374 Coverage includes thermostat and economizer Equipment installed within 1 mile of salt water or environment with high sulfur content should use the S warranty models. The Warranty would be the same as below with an S in the 7th digit instead of the 0 below. For example, use TAYWARS064 instead of TAYWAR0064. WARRANTY # TAYWAR0064 TAYWAR0065 TAYWAR0066 TAYWAR0067 TAYWAR0068 TAYWAR0363 TAYWAR0069 TAYWAR0364 TAYWAR0365 TAYWAR0070 TAYWAR0366 TAYWAR0367 TAYWAR0071 TAYWAR0072 TAYWAR0368 TAYWAR0369 TAYWAR0073 TAYWAR0370 TAYWAR0371 TAYWAR0074 TAYWAR4042 TAYWAR0372 TAYWAR0373 TAYWAR0075 TAYWAR0374 TONS 1-5 1-5 1-5 1-5 1-5 1-5 ALL 6.25 - 7.50 6.25 - 7.50 6.25 - 7.50 8.50 - 10 8.50 - 10 8.50 - 10 12.50 12.50 12.50 15 - 17.50 15 - 17.50 15 - 17.50 20 20 20 20 25 25 DESCRIPTION TERM CONDENSING UNIT 1 YR PACKAGE OR SPLIT SYSTEM 1 YR AIR HANDLER 1 YR GAS/ELECTRIC UNIT 1 YR FURNACE 1 YR PACKAGE OR SPLIT SYSTEM 5 YR TRANE ELECTRONIC AIR CLEANER 1 YR PACKAGE UNIT 5 YR SPLIT SYSTEM 5 YR PACKAGE OR SPLIT SYSTEM 1 YR PACKAGE UNIT 5 YR SPLIT SYSTEM 5 YR PACKAGE OR SPLIT SYSTEM 1 YR PACKAGE OR SPLIT SYSTEM 1 YR PACKAGE UNIT 5 YR SPLIT SYSTEM 5 YR PACKAGE OR SPLIT SYSTEM 1 YR PACKAGE UNIT 5 YR SPLIT SYSTEM 5 YR PACKAGE OR SPLIT SYSTEM 1 YR COMPRESSOR ONLY 1 YR PACKAGE UNIT 5 YR SPLIT SYSTEM 5 YR PACKAGE OR SPLIT SYSTEM 1 YR PACKAGE UNIT 5 YR COVERAGE LABOR ONLY LABOR ONLY LABOR ONLY LABOR ONLY LABOR ONLY PARTS & LABOR LABOR ONLY PARTS & LABOR PARTS & LABOR LABOR ONLY PARTS & LABOR PARTS & LABOR LABOR ONLY LABOR ONLY PARTS & LABOR PARTS & LABOR LABOR ONLY PARTS & LABOR PARTS & LABOR LABOR ONLY LABOR ONLY PARTS & LABOR PARTS & LABOR LABOR ONLY PARTS & LABOR
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2005 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 14
These Optional Extended Warranties apply to Trane or Command-Aire complete Water Source package or split systems installed in Residential Applications. Coverage includes internal components within the system and thermostat, excludes the ground water loop. Some warranties apply to compressors only used in Water Source systems installed in Residential Applications. One (1) -year warranties apply to equipment less than five (5) years old and can be renewed each year until the equipment is ten (10) years old when accepted by the Extended Warranty Department. Five (5)- and ten (10) -year warranties expire five (5) or ten (10) years from the installation date of the covered equipment no matter when purchased. Equipment installed within 1 mile of salt water or environment with high sulfur content should use the S warranty models. The Warranty would be the same as below with an S in the 7th digit instead of the 0 below. For example, use TAYWARS111 instead of TAYWAR0111. WARRANTY # TAYWAR0111 TAYWAR0112 TAYWAR0113 TAYWAR0114 TAYWAR0115 TAYWAR0116 TAYWAR0117 TAYWAR0118 TAYWAR0119 TAYWAR0255 TAYWAR0309 TAYWAR0310 TAYWAR0311 TAYWAR0312 TAYWAR0313 TAYWAR0314 TAYWAR0315 TAYWAR0316 TAYWAR0317 TAYWAR0318 TONS 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 6 6 6 6 6 6 6 6 6 6 DESCRIPTION COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM TERM 1 YR 1 YR 10 YR 10 YR 1 YR 1 YR 5 YR 5 YR 10 YR 10 YR 1 YR 1 YR 10 YR 10 YR 1 YR 1 YR 5 YR 5 YR 10 YR 10 YR COVERAGE PARTS ONLY PARTS AND LABOR PARTS ONLY PARTS AND LABOR PARTS ONLY PARTS AND LABOR PARTS ONLY PARTS AND LABOR PARTS ONLY PARTS AND LABOR PARTS ONLY PARTS AND LABOR PARTS ONLY PARTS AND LABOR PARTS ONLY PARTS AND LABOR PARTS ONLY PARTS AND LABOR PARTS ONLY PARTS AND LABOR
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2007 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 15
These Optional Extended Warranties apply to Trane or Command-Aire complete Water Source package or split systems installed in Commercial Applications. Coverage includes internal components within the system and thermostat, excludes ground water loop. Some warranties apply to compressors only used in Water Source systems installed in Commercial Applications. One (1) -year warranties apply to equipment less than five (5) years old and can be renewed each year until the equipment is ten (10) years old when accepted by the Extended Warranty Department. Five (5)- and ten (10) -year warranties expire 5 (five) or 10 (ten) years from the installation date of the covered equipment no matter when purchased. Equipment installed within 1 mile of salt water or environment with high sulfur content should use the S warranty models. The Warranty would be the same as below with an S in the 7th digit instead of the 0 below. For example, use TAYWARS375 instead of TAYWAR0375. WARRANTY # TAYWAR0375 TAYWAR0376 TAYWAR0377 TAYWAR0378 TAYWAR0379 TAYWAR0380 TAYWAR0381 TAYWAR0382 TAYWAR0383 TAYWAR0384 TAYWAR0385 TAYWAR0386 TAYWAR0387 TAYWAR0388 TAYWAR0389 TAYWAR0390 TAYWAR0391 TAYWAR0392 TAYWAR0393 TAYWAR0394 TONS 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 1-5 6 6 6 6 6 6 6 6 6 6 DESCRIPTION COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM PACKAGE OR SPLIT SYSTEM TERM 1 YR 1 YR 10 YR 10 YR 1 YR 1 YR 5 YR 5 YR 10 YR 10 YR 1 YR 1 YR 10 YR 10 YR 1 YR 1 YR 5 YR 5 YR 10 YR 10 YR COVERAGE PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS & LABOR PARTS ONLY PARTS AND LABOR PARTS ONLY PARTS AND LABOR PARTS ONLY PARTS AND LABOR
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2005 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 16
These Optional Extended Warranties apply to the equipment noted in the description that are installed in Residential or Commercial Applications. These warranties do not allow for any mark-ups on part. Servicer is reimbursed for the cost of the part based on the parts invoice. No-markup is paid on any part, whether in or out of warranty. Five (5)- through twelve (12) -year warranties expire five (5) through twelve (12) years from the installation date of the covered equipment no matter when purchased. WARRANTY # TONS TAYWAR40462 1-5 TAYWAR40752 1-5 TAYWAR40772 1-5 TAYWAR40782 1-5 TAYWAR40792 1-5 TAYWAR40512 1-5 TAYWAR41182 1-5 TAYWAR411936.25-12.50 TAYWAR41203 15-25 TAYWAR41173 15-20 TAYWAR41213 25 TAYWAR41232 1-5 TAYWAR41432 1-5 TAYWAR41442 1-5 TAYWAR41452 1-5 TAYWAR41462 1-5 TAYWAR41502 1-5 TAYWAR41512 1-5 TAYWAR41522 1-5 DESCRIPTION CONDENSING UNIT ONLY PACKAGE OR SPLIT SYSTEM FURNACE OR AIR HANDLER FURNACE OR AIR HANDLER, VARIABLE SPEED CONDENSING UNIT ONLY (XE or XL) COMPRESSR ONLY EPOXY COATED EVAPORATOR COIL (Indoor or outdoor) EPOXY COATED EVAPORATOR COIL (Indoor or outdoor) EPOXY COATED EVAPORATOR COIL (Indoor or outdoor) COMPRESSOR ONLY COMPRESSOR ONLY COMPRESSOR ONLY FURNACE OR AIR HANDLER FURNACE OR AIR HANDLER, VARIABLE SPEED CONDENSING UNIT ONLY PACKAGE OR SPLIT SYSTEM XE CONDENSING UNIT NO PARTS MARK UP XE CONDENSING UNIT NO PARTS MARK UP XE PACKAGE OR SPLIT SYSTEM NON-VARIABLE SPEED AIR HANDLER OR FURNACE - NO PARTS MARK UP XE PACKAGE OR SPLIT SYSTEM NON-VARIABLE SPEED AIR HANDLER OR FURNACE - NO PARTS MARK UP TERM 5 YR 10 YR 10 YR 10 YR 10 YR 10 YR 5 YR 5 YR 5 YR 5 YR 5 YR 12 YR 12 YR 12 YR 12 YR 12 YR 5 YR 10 YR 5 YR COVERAGE PARTS ONLY PARTS ONLY PARTS ONLY PARTS ONLY PARTS ONLY PARTS ONLY PARTS ONLY PARTS ONLY PARTS ONLY PARTS ONLY PARTS ONLY PARTS ONLY PARTS ONLY PARTS ONLY PARTS ONLY PARTS ONLY PARTS & LABOR PARTS & LABOR PARTS & LABOR
TAYWAR41532
1-5
10 YR
All XB units and M Package Units are not eligible if installed or initial warranty sale date is after 10/01/2001. Residential or Commercial Application. Commercial Application.
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2007 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 17
Extended Warranties
GENERAL NOTES
1. All one (1) -year term Agreements are initially intended to be sold on equipment less than five (5) years old. There Agreements can be renewed each year until the equipment is ten (10) years old when accepted by the Extended Warranty Department. Coverage begins thirty (30) days after Agreement is sold and requires a written statement from Servicer/Dealer stating that the condition of the equipment is acceptable for the initial sale. No statement is required for renewals unless there is a lapse in coverage. 2. All other Agreements with terms of five (5) years or greater should be sold at time of equipment sale, but may be sold on older equipment. Special provisions apply. See your Extended Warranty Handbook or additional information. Any Agreement with terms of five (5) years or greater expire based on the original install date, not the purchase date of the Agreement. 3. Any desired Agreement with terms requested other than those listed with part numbers must be approved by the Trane Extended Warranty Department at 800-554-6413. 4. An X In the eleventh (11) digit of the extended warranty model number is used only to determine a price for that particular warranty when labor option #3 is chosen. See the Extended Warranty Handbook for details. 5. An S in the seventh (7) digit of the Optional Extended Warranty model number is used when the equipment is installed within 1 mile of salt water or in an environment with high sulfur content or where specifically requested by the Extended Warranty Department.
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2005 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 18
TAYWAR0002
TAYWAR0003
TAYWAR0004
TAYWAR0011
TAYWAR0012
TAYWAR0013
TAYWAR0014
TAYWAR0015
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2007 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 19
TAYWAR0017
TAYWAR0018
TAYWAR0019
TAYWAR0020
TAYWAR0021
TAYWAR0022
TAYWAR0023
TAYWAR0024
TAYWAR0025
TAYWAR0026
TAYWAR0030
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2005 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 20
TAYWAR0034
TAYWAR0035
TAYWAR0036
TAYWAR0037
TAYWAR0038
TAYWAR0039
TAYWAR0040
TAYWAR0041
TAYWAR0042
TAYWAR0043
TAYWAR0044
TAYWAR0045
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2007 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 21
TAYWAR0047
TAYWAR0048
TAYWAR0053
TAYWAR0054
TAYWAR0055
TAYWAR0056
TAYWAR0057
TAYWAR0058
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2005 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 22
TAYWAR0060
TAYWAR0061
TAYWAR0062
TAYWAR0064
TAYWAR0065
TAYWAR0066
TAYWAR0067
TAYWAR0068
TAYWAR0069
TAYWAR0070
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2007 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 23
TAYWAR0072
TAYWAR0073
TAYWAR0074
TAYWAR0075
TAYWAR0076
TAYWAR0077
TAYWAR0078
TAYWAR0079
TAYWAR0080
TAYWAR0081
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2005 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 24
TAYWAR0083
TAYWAR0084
TAYWAR0085
TAYWAR0086
TAYWAR0087
TAYWAR0088
TAYWAR0091
TAYWAR0092
TAYWAR0093
TAYWAR0094
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2007 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 25
TAYWAR0096
TAYWAR0097
TAYWAR0098
TAYWAR0099
TAYWAR0100
TAYWAR0101
TAYWAR0102
TAYWAR0103
TAYWAR0104
TAYWAR0105
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2005 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 26
TAYWAR0108
TAYWAR0109
TAYWAR0111
TAYWAR0112
TAYWAR0113
TAYWAR0114
TAYWAR0115
TAYWAR0116
TAYWAR0117
TAYWAR0118
TAYWAR0119
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2007 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 27
TAYWAR0121
TAYWAR0122
TAYWAR0123
TAYWAR0124
TAYWAR0125
TAYWAR0127
TAYWAR0128
TAYWAR0129
TAYWAR0130
TAYWAR0131
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2005 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 28
TAYWAR0137
TAYWAR0138
TAYWAR0139
TAYWAR0141
TAYWAR0142
TAYWAR0143
TAYWAR0144
TAYWAR0145
TAYWAR0146
TAYWAR0153
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2007 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 29
TAYWAR0159
TAYWAR0160
TAYWAR0161
TAYWAR0162
TAYWAR0163
TAYWAR0164
TAYWAR0165
TAYWAR0166
TAYWAR0167
TAYWAR0168
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2005 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 30
TAYWAR0170
TAYWAR0171
TAYWAR0172
TAYWAR0173
TAYWAR0174
TAYWAR0175
TAYWAR0182
TAYWAR0183
TAYWAR0188
TAYWAR0189
TAYWAR0190
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2007 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 31
TAYWAR0192
TAYWAR0193
TAYWAR0194
TAYWAR0195
TAYWAR0196
TAYWAR0197
TAYWAR0198
TAYWAR0199
TAYWAR0200
TAYWAR0201
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2005 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 32
TAYWAR0203
TAYWAR0204
TAYWAR0205
TAYWAR0206
TAYWAR0207
TAYWAR0208
TAYWAR0209
TAYWAR0210
TAYWAR0211
TAYWAR0212
TAYWAR0213
TAYWAR0214
TAYWAR0215
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2007 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 33
TAYWAR0217
TAYWAR0218
TAYWAR0219
TAYWAR0220
TAYWAR0221
TAYWAR0222
TAYWAR0223
TAYWAR0224
TAYWAR0225
TAYWAR0226 TAYWAR0227
TAYWAR0228
TAYWAR0229
TAYWAR0230
TAYWAR0231
TAYWAR0232
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2005 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 34
TAYWAR0234
TAYWAR0235
TAYWAR0236
TAYWAR0237
TAYWAR0238
TAYWAR0239
TAYWAR0240
TAYWAR0241
TAYWAR0242
TAYWAR0243
TAYWAR0244
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2007 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 35
TAYWAR0247
TAYWAR0248
TAYWAR0249
TAYWAR0250
TAYWAR0251
TAYWAR0252
TAYWAR0253
TAYWAR0254
TAYWAR0255
TAYWAR0256
TAYWAR0257
TAYWAR0260
TAYWAR0261
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2005 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 36
TAYWAR0263
TAYWAR0264
TAYWAR0265
TAYWAR0267
TAYWAR0268
TAYWAR0269
TAYWAR0270
TAYWAR0271
TAYWAR0272
TAYWAR0273
TAYWAR0274
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2007 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 37
TAYWAR0276
TAYWAR0277
TAYWAR0278
TAYWAR0279
TAYWAR0280
TAYWAR0281
TAYWAR0282
TAYWAR0283
TAYWAR0284
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2005 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 38
TAYWAR0286
TAYWAR0288
TAYWAR0289
TAYWAR0290
TAYWAR0291
TAYWAR0293
TAYWAR0294
TAYWAR0295
TAYWAR0296
TAYWAR0309
TAYWAR0310
TAYWAR0311
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2007 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 39
TAYWAR0313
TAYWAR0314
TAYWAR0315
TAYWAR0316
TAYWAR0317
TAYWAR0318
TAYWAR0319
TAYWAR0320
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2005 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 40
TAYWAR0322
TAYWAR0323
TAYWAR0324
TAYWAR0325
TAYWAR0326
TAYWAR0327
TAYWAR0331
TAYWAR0334
TAYWAR0362
TAYWAR0363
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2007 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 41
TAYWAR0365
TAYWAR0366
TAYWAR0367
TAYWAR0368
TAYWAR0369
TAYWAR0370
TAYWAR0371
TAYWAR0372
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2005 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 42
TAYWAR0374
TAYWAR0375
TAYWAR0376
TAYWAR0377
TAYWAR0378
TAYWAR0379
TAYWAR0380
TAYWAR0381
TAYWAR0382
TAYWAR0383
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2007 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 43
TAYWAR0385
TAYWAR0386
TAYWAR0387
TAYWAR0388
TAYWAR0389
TAYWAR0390
TAYWAR0391
TAYWAR0392
TAYWAR0393
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2005 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 44
TAYWAR0395
TAYWAR0396
TAYWAR0397
TAYWAR0398
TAYWAR0399
TAYWAR0400
TAYWAR0401
TAYWAR0402
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2007 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 45
TAYWAR0404
TAYWAR0405
TAYWAR0406
TAYWAR0407
TAYWAR0408
TAYWAR0409
TAYWAR0410
TAYWAR0411
TAYWAR4003
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2005 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 46
TAYWAR4039 TAYWAR4040
TAYWAR4041
TAYWAR4042 TAYWAR4046
TAYWAR4051
TAYWAR4057
TAYWAR4058
TAYWAR4059
TAYWAR4060
TAYWAR4061
TAYWAR4071
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2007 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 47
TAYWAR4075
TAYWAR4077
TAYWAR4078
TAYWAR4079
TAYWAR4082
TAYWAR4083
TAYWAR4086
TAYWAR4087
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2005 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 48
TAYWAR4094
TAYWAR4095
TAYWAR4096
TAYWAR4098
TAYWAR4099
TAYWAR4100
TAYWAR4107
TAYWAR4108
TAYWAR4109
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2007 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 49
TAYWAR4117
TAYWAR4118
TAYWAR4119
TAYWAR4120
TAYWAR4121
TAYWAR4123
TAYWAR4124
TAYWAR4143
TAYWAR4144
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2005 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 50
TAYWAR4146
TAYWAR4148
TAYWAR4150
TAYWAR4151
TAYWAR4152
TAYWAR4153
TAYWAR4198
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2007 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 51
TAYWAR4200
TAYWAR4201
TAYWAR4202
TAYWAR4203
TAYWAR4204
TAYWAR4205
TAYWAR4206
TAYWAR4207
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2005 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 52
TAYWAR4209
TAYWAR4210
TAYWAR4211
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2007 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 53
Assurance of Commitment
Trane dealer assigned to their agreement has up-to-date knowledge of equipment and service techniques Optional Extended Warranty is transferrable to subsequent homeowners should the original owner sell their home Cost effective as compared to other Extended Warranties (i.e., appliances, consumer electronics, automobiles)
Dealer Benefits
Labor Coverage after 90th Day (lower labor reserves) Optional Extended Warranty contracts assign selling dealer as servicer of record which locks in customer for the life of the warranty Provides In Warranty parts markup (revenue opportunity) Additional profit opportunity by selling the Optional Extended Warranty (gross profit becomes close to net profit) Repair/Replace option allows consumer to apply repair costs toward purchase price of new equipment Dealer provides more comprehensive coverage which improves customer satisfaction with dealer and Trane Encourages the sale of Maintenance Agreements Commercial Product up to 25 tons can be covered up to 10 years for parts and labor New construction dealer can include Optional Extended Warranties, capturing customers they normally dont see (if agreement is put in the builders name, the agreement can be transferred to the new homeowner at no charge)
*Covers labor, refrigerant, diagnostics, and parts, subject to product coverage and terms and conditions.
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2005 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
WA 54
Difference
$ $ $ $ -
Parts
Coil (.5 x normal cost) $ 250.00 R410A (2 x #lbs. x dealer cost) $ 154.00 $ 894.00 $ 327.00
$ 250.00 $ -
$ 250.00 $ 250.00
In the above example, even with a 10-year Limited Warranty on parts, the consumer still paid $644 for a coil replacement, and you made only $77 in profit on parts. With the Optional Extended Warranty, the consumer pays nothing for the repair and you made an additional $250 in profit on parts
Selling Story:
The Optional Extended Warranty should be offered at time of sale (can be included with financing) Use the Optional Extended Warranty Sales Brochure, Pub. No. 26-1016-07 and the consumer benefits on the reverse side Point out that Limited Warranty does not cover refrigerant or labor If the Optional Extended Warranty is included in the total proposal, it is much easier to sell If you are in a regulated state, you must provide the actual purchase price (not to be less than your actual cost) on the Optional Extended Warranty Application. This amount will appear on the consumers agreement (see your Extended Warranty Handbook for more information on selling Optional Extended Warranties in regulated states)
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the 2007 Trane Product Catalog. However, the information in the Trane Optional Extended Warranty Handbook (Publication No. 26-1019) supersedes all information contained herein.
2002 American Standard Inc. All Rights Reserved
WA 55
Economizer Actuator Logic Module is required with FIOPS (Factory Installed Options) Enthalpy and Novar Controls.
Must select Economizer Actuator Logic Module (FIYLGCM001A) in order to configure and price a Voyager unit. This module does not need to be selected when ordering the field installed accessory.
FIYENTH007A Reference Enthalpy FIYENTH008A Comparative Enthalpy TCI FIYICSI004B Trane Communication Interface LCI FIYLTCI003B LonTalk Interface Discharge Air Sensing Kit FIYTUBE009A FIYTUBE008A Discharge Air Sensing Kit Discharge Air Sensing Kit
Downflow Units w/A,C or G in 10th Digit Downflow Units w/A,C or G in 10th Digit TC*150-301** TC*150-301
Used for true discharge air sensing in models with electric heat. Functional only with ReliaTelTM Options Module (FIYABRD002B).
Convenience Outlet
Must be ordered with Through-the-Base Electrical option and either Unit Mounted Disconnect or Circuit Breaker (downflow only).
FIYCOPO201A Powered, 120V Convenience Outlet, 230V TCD150-300*3 FIYCOPO202A Powered, 120V Convenience Outlet, 460V TCD150-300*4 FIYCOUP201A Unpowered, 115V Convenience Outlet TCD150-300 Tool-less Condenser Hail Guard FIYGARD001B Tool-less Condenser Hail Guard TC*150D FIYGARD002B Tool-less Condenser Hail Guard TC*151C,180B,210C FIYGARD003A Tool-less Condenser Hail Guard TC*181C,211C,241C,301C,240B FIYGARD005A Tool-less Condenser Hail Guard TC*300B Novar Controls
The Novar control option includes the following factory installed and wired devices: Novar ETM-2024 rooftop controller, fan proving switch, clogged filter or unit shutdown switch, Cool 1,Cool 2, Heat switch and discharge air sensor (downflow only) (Novar # DTS-30, 20-170F). NOTE: Option cannot be ordered in conjunction with FIOPS Smoke Detector option. Novar Controls with an economizer in the 10th digit (Digit 10=A,C,G,K,L,N,R) will also be required to select the Economizer Actuator Logic Module.
FIYCNTL013A Novar Control, 208-230V FIYCNTL015A Novar Control, 460 & 575V Novar Controls-3051
TCD150-301*3 TCD150-301*4,W
The Novar control option includes the following factory installed and wired devices: Novar 3051 rooftop controller, fan proving switch, clogged filter or unit shutdown switch, and discharge air sensor (Novar # DTS-30, 20-170F) (downflow only). NOTE: This option can be ordered in conjunction with factory installed Smoke Detector option. It cannot be ordered in conjunction with with economizer, either field or factory installed. Novar Controls with an economizer in the 10th digit (Digit 10=A,C,G,K,L,N,R) will also be required to select the Economizer Actuator Logic Module.
Novar Control, 460 and 575V Novar Control, 208-230V Novar Control, 460 and 575V Novar Control, 208-230V
This option consist of a Novar Zone Sensor (Novar #WTS-SOS) used with Novar 3051 Controls.
FIYCNTL016A
FIOP 1
Accessories:
Model Number Description Novar Return Air Sensor FIYNRAS001A Return Air Sensor Filter & Control Access
(Downflow units only)
This option consists of the Novar return air sensor (Novar # WTS-10) that is wired and shipped in the return air section of the unit. The sensor ships with approximately 15' of extra wire for dropping down the return air duct (downflow only).
Hinged Filter/Evap. and Comp./Control Access Door Hinged Filter/Evap. and Comp./Control Access Door Hinged Filter/Evap. and Comp./Control Access Door Hinged Filter/Evap. and Comp./Control Access Door
Disconnect Switch
Must be used with Through-the-Base Electrical option (downflow only). Cannot be fused.
FIYUDC4150A Unit Mounted Disconnect Switch FIYUDC3250A Unit Mounted Disconnect Switch FIYUDC6100A Unit Mounted Disconnect Switch High Efficiency Motors
Can use used on downflow or horizontal units unless specified on matrix sheets.
FIYHEMT001A FIYHEMT002A FIYHEMT003A FIYHEMT004A FIYHEMT005A FIYHEMT006A FIYHEMT007A FIYHEMT008A FIYHEMT009A FIYHEMT010A FIYHEMT011A Circuit Breaker FIYUCB4015A FIYUCB4020A FIYUCB4025A
2 HP High Effic. Motor (86.5 Eff.)(208-230/460/60/3) 2 HP High Effic. Motor (86.5 Eff.)(575/60/3) 3 HP High Effic. Motor (89.5 Eff.)(208-230/60/3) 3 HP High Effic. Motor (89.5 Eff.)(460/60/3) 3 HP High Effic. Motor (89.5 Eff.)(575/60/3) 5 HP High Effic. Motor (91.0 Eff.)(208-230/60/3) 5 HP High Effic. Motor (91.0 Eff.)(460/60/3) 5 HP High Effic. Motor (91.0 Eff.)(575/60/3) 7 HP High Effic. Motor (90.2 Eff.)(208-230/60/3) 7 HP High Effic. Motor (90.2 Eff.)(460/60/3) 7 HP High Effic. Motor (90.2 Eff.)(575/60/3)
Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets
Unit Mounted Circuit Breaker Unit Mounted Circuit Breaker Unit Mounted Circuit Breaker
FIOP 2
Accessories:
Model Number Description Circuit Breaker (Contd.) FIYUCB4030A Unit Mounted Circuit Breaker FIYUCB4035A Unit Mounted Circuit Breaker FIYUCB4040A Unit Mounted Circuit Breaker FIYUCB4045A Unit Mounted Circuit Breaker FIYUCB4050A Unit Mounted Circuit Breaker FIYUCB4060A Unit Mounted Circuit Breaker FIYUCB4070A Unit Mounted Circuit Breaker FIYUCB4080A Unit Mounted Circuit Breaker FIYUCB4090A Unit Mounted Circuit Breaker FIYUCB4100A Unit Mounted Circuit Breaker FIYUCB4110A Unit Mounted Circuit Breaker FIYUCB4125A Unit Mounted Circuit Breaker FIYUCB4150A Unit Mounted Circuit Breaker FIYUCB3175A Unit Mounted Circuit Breaker FIYUCB3200A Unit Mounted Circuit Breaker FIYUCB3225A Unit Mounted Circuit Breaker FIYUCB3250A Unit Mounted Circuit Breaker FIYUCB6110A Unit Mounted Circuit Breaker FIYUCB6125A Unit Mounted Circuit Breaker Through the Base Electrical FIYTBUE102A FIYTBUE103A FIYTBUE104A FIYTBUE106A FIYTBUE107A FIYTBUE108A FIYTBUE110A FIYTBUE111A FIYTBUE202A FIYTBUE203A FIYTBUE204A FIYTBUE205A FIYTBUE207A FIYTBUE208A FIYTBUE209A FIYTBUE210A FIYTBUE211A FIYTBUE212A FIYTBUE213A FIYTBUE214A FIYTBUE215A FIYTBUE216A Electric Heat FIDHTRA309B FIDHTRA318B FIDHTRA327B FIDHTRA336B FIDHTRD318A FIDHTRD336A FIDHTRD354A FIDHTRF318A
Must be used with Unit Mounted Disconnect Switch or Unit Mounted Circuit Breaker (downflow only). When adding heat, must order Trane Electric Heat. If no factory installed Unit Mounted disconnect Switch or Unit Mounted Circuit Breaker is required, order the Through the Base Utility Access Option (FIYTBUA****)from page FIOP6
Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option
Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets
Factory Installed 9 KW Electric Heat Factory Installed 18 KW Electric Heat Factory Installed 27 KW Electric Heat Factory Installed 36 KW Electric Heat Factory Installed 18 KW Electric Heat Factory Installed 36 KW Electric Heat Factory Installed 54 KW Electric Heat Factory Installed 18 KW Electric Heat FIOP 3
See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets Effective date: January 1, 2007
Accessories:
Model Number FIDHTRK336A FIDHTRK354A FIDHTRL336A FIDHTRL354A FIDHTRK372A FIDHTRJ318A FIDHTRJ336A FIDHTRA409B FIDHTRA418B FIDHTRA427B FIDHTRA436B FIDHTRC418A FIDHTRD436A FIDHTRD454A FIDHTRL418A FIDHTRK436A FIDHTRK454A FIDHTRL436A FIDHTRL454A FIDHTRK472A FIDHTRJ418A FIDHTRJ436A FIDHTRAW18B FIDHTRAW27B FIDHTRCW18A FIDHTRCW36A FIDHTRCW54A FIDHTRKW18A FIDHTRKW54A FIDHTRMW36A FIDHTRLW54A FIDHTRKW72A FIDHTRJW18A FIDHTRJW36A FIHHTRA309B FIHHTRA318B FIHHTRA327B FIHHTRA336B FIHHTRD318A FIHHTRD336A FIHHTRD354A FIHHTRM318A FIHHTRM336A FIHHTRM354A FIHHTRN336A FIHHTRN354A FIHHTRN372A FIHHTRJ318A FIHHTRJ336A FIHHTRA409B FIHHTRA418B FIHHTRA427B
Accessories:
Model Number Description
FIHHTRA436B Factory Installed 36 KW Electric Heat FIHHTRM418A Factory Installed 18 KW Electric Heat FIHHTRM436A Factory Installed 36 KW Electric Heat FIHHTRM454A Factory Installed 54 KW Electric Heat FIHHTRN436A Factory Installed 36 KW Electric Heat FIHHTRN454A Factory Installed 54 KW Electric Heat FIHHTRN472A Factory Installed 72 KW Electric Heat FIHHTRJ418A Factory Installed 18 KW Electric Heat FIHHTRJ436A Factory Installed 36 KW Electric Heat FIHHTRAW18B Factory Installed 18 KW Electric Heat FIHHTRAW27B Factory Installed 27 KW Electric Heat FIHHTRMW18A Factory Installed 18 KW Electric Heat FIHHTRMW36A Factory Installed 36 KW Electric Heat FIHHTRMW54A Factory Installed 54 KW Electric Heat FIHHTRNW54A Factory Installed 54 KW Electric Heat FIHHTRNW72A Factory Installed 72 KW Electric Heat FIHHTRJW18A Factory Installed 18 KW Electric Heat FIHHTRJW36A Factory Installed 36 KW Electric Heat FIHHTRN318A Factory Installed 18 KW Electric Heat FIHHTRN418A Factory Installed 18 KW Electric Heat FIHHTRNW18A Factory Installed 18 KW Electric Heat FIHHTRP336A Factory Installed 36 KW Electric Heat FIHHTRQ336A Factory Installed 36 KW Electric Heat FIHHTRP436A Factory Installed 36 KW Electric Heat FIHHTRQ436A Factory Installed 36 KW Electric Heat FIHHTRPW36A Factory Installed 36 KW Electric Heat FIHHTRP354A Factory Installed 54 KW Electric Heat FIHHTRQ354A Factory Installed 54 KW Electric Heat FIHHTRP454A Factory Installed 54 KW Electric Heat FIHHTRQ454A Factory Installed 54 KW Electric Heat FIHHTRPW54A Factory Installed 54 KW Electric Heat FIHHTRQW54A Factory Installed 54 KW Electric Heat FIYHTRP105A Factory Installed 6 KW Electric Heat FIYHTRP110A Factory Installed 10 KW Electric Heat FIYHTRP114A Factory Installed 14 KW Electric Heat FIYHTRP118A Factory Installed 18 KW Electric Heat FIYHTRP306A Factory Installed 6 KW Electric Heat FIYHTRP312A Factory Installed 12 KW Electric Heat FIYHTRP318A Factory Installed 18 KW Electric Heat FIYHTRP323A Factory Installed 23 KW Electric Heat FIYHTRP406A Factory Installed 6 KW Electric Heat FIYHTRP412A Factory Installed 12 KW Electric Heat FIYHTRP418A Factory Installed 18 KW Electric Heat FIYHTRP423A Factory Installed 23 KW Electric Heat FIYHTRPW06A Factory Installed 6 KW Electric Heat FIYHTRPW12A Factory Installed 12 KW Electric Heat FIYHTRPW18A Factory Installed 18 KW Electric Heat FIYHTRPW23A Factory Installed 23 KW Electric Heat Black Epoxy Coated Condenser Coil FIYCOIL205A Black Epoxy Coated Condenser Coil FIYCOIL206A Black Epoxy Coated Condenser Coil FIYCOIL209A Black Epoxy Coated Condenser Coil FIYCOIL210A Black Epoxy Coated Condenser Coil
FIOP 5
Used With
ReliaTel
Options Module
FIYABRD002B is required when ordering the following accessories: Clogged Filter Switch (FIYDFPS005A/BAYDFPS005A), Fan Fail Switch (FIYDFPS006A/BAYDFPS006A), Discharge Air Sensing Kit (FIYTUBE008A,FIYTUBE009A, BAYTUBE008A, BAYTUBE009A), Frostat (FIYLOAM023A, BAYLOAM023A), Ventilation Override (must order BAYVNOR002B), Smoke Detector (FIYSMDT).
FIYABRD002B ReliaTelTM Options Module All Voyager Units Return Air Smoke Detector for downflow units with economizer12
Option cannot be ordered in conjunction with field installed economizer.
FIYSMDT221A Return Air Smoke Detector TCD150,151,180,210 w/FIYABRD002B FIYSMDT223A Return Air Smoke Detector TCD181,211,240,241,300,301 w/FIYABRD002B Return Air Smoke Detector for downflow units without economizer12 FIYSMDT222A Return Air Smoke Detector FIYSMDT224A Return Air Smoke Detector Supply Air Smoke Detector for downflow units 2 TCD150,151,180,210 w/FIYABRD002B TCD181,211,240,241,300,301 w/FIYABRD002B
FIYSMDT225A Supply Air Smoke Detector TCD150,151,180,210 w/FIYABRD002B FIYSMDT228A Supply Air Smoke Detector TCD181,211,240,241,300,301 w/FIYABRD002B Supply and Return Air Smoke Detectors for downflow units with economizer12
Option cannot be ordered in conjunction with field installed economizer.
FIYSMDT226A Supply and Return Air Smoke Detector TCD150,151,180,210 w/FIYABRD002B FIYSMDT229A Supply and Return Air Smoke Detector TCD181,211,240,241,300,301 w/FIYABRD002B Supply and Return Air Smoke Detectors for downflow units without economizer12 FIYSMDT227A FIYSMDT230A Supply and Return Air Smoke Detector Supply and Return Air Smoke Detector TCD150,151,180,210 w/FIYABRD002B TCD181,211,240,241,300,301 w/FIYABRD002B
1 The return air smoke detector may not fit up or work properly on the Voyager units when used in conjunction with 3rd party accessories (such as bolt on heat wheels, economizers, and power exhaust). Do not order the return air smoke detectors when using this type of accessory. 2 Smoke Detectors available for downflow units only.
FIYTBUA205A FIYTBUA207A 2" Pleated Filters FIYPLTD001A FIYPLTD002A FIYPLTD003A Frostat FIYLOAM023A
Through the Base Utilities Access Through the Base Utilities Access 2" Pleated Filters 2" Pleated Filters 2" Pleated Filters Frostat
TCD150,151,180,210*3,4 TCD181,211,240,241,300,301*3,4 TCD/TCH150,151,180,210 TCD/TCH181,211,240,241,300,301 TCD/TCH181,211,240,241,300,301 TCD151,181,241-3,4, W with H,J,K,L in 10th digit w/FIYABRD002B
FIOP 6
FIOP 7
TFD150D300B TFD150D30BB TFD150D400B TFD150D40BB TFD150DW00B TFD150DW0BB TFD151C300B TFD151C30BB TFD151C400B TFD151C40BB TFD151CW00B TFD151CW0BB TFD151C30HB TFD151C30JB TFD151C40HB TFD151C40JB TFD151CW0HB TFD151CW0JB TFD180B300H TFD180B30BH TFD180B400H TFD180B40BH TFD180BW00H TFD180BW0BH TFD181C300C TFD181C30BC TFD181C30MC TFD181C30NC TFD181C30PC TFD181C30RC TFD181C400C TFD181C40BC TFD181C40MC TFD181C40NC TFD181C40PC TFD181C40RC TFD181CW00C TFD181CW0BC TFD181CW0MC TFD181CW0NC TFD181CW0PC TFD181CW0RC TFD181C30HC TFD181C30JC TFD181C40HC TFD181C40JC TFD181CW0HC TFD181CW0JC
003 006 004 007 005 008 003 006 004 007 005 008 003 006 004 007 005 008 003 006 004 007 005 008 003 006 003 003 006 006 004 007 004 004 007 007 005 008 005 005 008 008 003 006 004 007 005 008
CO* 207 207 207 207 207 207 207 207 207 207 207 207 207 207 207 207 207 207 207 207 207 207 207 207 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213
18KW 208 208 208 208 208 208 208 208 208 208 208 208 208 208 208 208 208 208 208 208 208 208 208 208 214 214 214 214 214 214 214 214 214 214 214 214 214 214 214 214 214 214 214 214 214 214 214 214
27KW N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 214 N/A 214 214 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 214 N/A N/A N/A
36KW 209 209 208 208 208 208 209 209 208 208 208 208 209 209 208 208 208 208 209 209 208 208 208 208 215 215 215 215 215 215 214 214 214 214 214 214 214 214 214 214 214 214 215 215 214 214 214 214
54KW 210 210 208 208 208 208 210 210 208 208 208 208 210 210 208 208 208 208 210 210 208 208 208 208 216 216 216 216 216 216 214 214 214 214 214 214 214 214 214 214 214 214 216 216 214 214 214 214
72KW N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
CO* 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100
18KW 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100
27KW N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 6100 N/A 6100 6100 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 6100 N/A N/A N/A
36KW 4150 4150 6100 6100 6100 6100 4150 4150 6100 6100 6100 6100 4150 4150 6100 6100 6100 6100 4150 4150 6100 6100 6100 6100 4150 4150 4150 4150 4150 4150 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 4150 4150 6100 6100 6100 6100
54KW 3250 3250 6100 6100 6100 6100 3250 3250 6100 6100 6100 6100 3250 3250 6100 6100 6100 6100 3250 3250 6100 6100 6100 6100 3250 3250 3250 3250 3250 3250 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 3250 3250 6100 6100 6100 6100
72KW N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
CO* 4080 4080 4040 4040 4030 4035 4080 4090 4040 4040 4030 4035 4070 4080 4035 4040 4030 4030 4090 4100 4050 4050 4040 4040 4090 4100 4090 4090 4100 4100 4050 4050 4045 4045 4050 4050 4040 4040 4035 4035 4040 4040 4090 4090 4050 4050 4040 4040
18KW 4080 4080 4040 4040 4030 4035 4080 4090 4040 4040 4030 4035 4070 4080 4035 4040 4030 4030 4100 4100 4050 4050 4040 4040 4100 4100 4090 4090 4100 4100 4050 4050 4045 4045 4050 4050 4040 4040 4035 4035 4040 4040 4100 4090 4050 4050 4040 4040
27KW N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 4050 N/A 4050 4050 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 4050 N/A N/A N/A
36KW 6125 4150 4070 4070 4050 4060 6125 4150 4070 4070 4050 4060 6125 4150 4070 4070 4050 4060 6125 4150 4070 4070 4050 4060 6125 4150 6125 6125 4150 4150 4070 4070 4070 4070 4070 4070 4050 4060 4050 4050 4060 4060 6125 4150 4070 4070 4050 4060
54KW 3200 3200 4090 4100 4070 4080 3200 3200 4090 4100 4070 4080 3200 3200 4090 4100 4070 4080 3200 3200 4090 4100 4070 4080 3200 3200 3200 3200 3200 3200 4090 4100 4090 4090 4100 4100 4070 4080 4070 4070 4080 4080 3200 3200 4090 4100 4070 4080
72KW N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
ALL FACTORY INSTALLED Unit model # changes to "F" in 2nd digit, indicating desire for factory installed options (unit nameplate will still reflect standard model #, i.e. TCD). OPTIONS ARE BUILT-TO-ORDER. Unit mounted disconnect and circuit breakers are mutually exclusive of each other. Through-the-base electrical option must be ordered with either unit mounted disconnect or circuit breaker. When adding heat, must order Trane Electric Heat. CHECK ORDER SERVICES FOR When ordering economizer ("A" in 10th digit), TCI ("F" in 10th digit), or economizer and TCI ("G" in 10th digit) use line with m odel number with "0" in 10th digit for ESTIMATED PRODUCTION CYCLE. FIOP selections; when ordering oversized motor ("B" in 10th digit) or oversized motor & economizer ("C" in 10th digit) uses line with model number with "B" in 10th digit for FIOP selections. When ordering thermal expansion valve ("H" in 10th digit) with economizer ("L" in 10th digit) use line with model number with "H" in the 10th digit for FIOP selections; when ordering thermal expansion valve with oversized motor ("J" in 10th digit) or oversized motor & economizer ("K" in 10th digit) uses line with model number with "J" in 10th digit for FIOP selections. (5) High efficiency motors can be factory installed on downflow and horizontal units unless noted. When ordering horizontal units with high efficiency motors, unit model # changes to "H" in 3rd digit. * Cooling Only
FIOP 8
TFD210C300E TFD210C30BE TFD210C400E TFD210C40BE TFD210CW00E TFD210CW0BE TFD211C300C TFD211C30BC TFD211C400C TFD211C40BC TFD211CW00C TFD211CW0BC TFD240B300J TFD240B30BJ TFD240B400J TFD240B40BJ TFD240BW00J TFD240BW0BJ TFD241C300C TFD241C30BC TFD241C30MC TFD241C30NC TFD241C30PC TFD241C30RC TFD241C400C TFD241C40BC TFD241C40MC TFD241C40NC TFD241C40PC TFD241C40RC TFD241CW00C TFD241CW0BC TFD241CW0MC TFD241CW0NC TFD241CW0PC TFD241CW0RC TFD241C30HC TFD241C30JC TFD241C40HC TFD241C40JC TFD241CW0HC TFD241CW0JC
006 009 007 010 008 011 006 009 007 010 008 011 006 009 007 010 008 011 006 009 006 006 009 009 007 010 007 007 010 010 008 011 008 008 011 011 006 009 007 010 008 011
CO* 207 207 207 207 207 207 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213 213
18KW N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
27KW N/A N/A N/A N/A N/A N/A N/A N/A 214 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 214 N/A 214 214 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 214 N/A N/A N/A
36KW 209 209 208 208 208 208 215 215 214 214 214 214 215 215 214 214 214 214 215 215 215 215 215 215 214 214 214 214 214 214 214 214 214 214 214 214 215 215 214 214 214 214
54KW 210 210 208 208 208 208 216 216 214 214 214 214 216 216 214 214 214 214 216 216 216 216 216 216 214 214 214 214 214 214 214 214 214 214 214 214 216 216 214 214 214 214
72KW N/A N/A N/A N/A N/A N/A 216 216 215 215 214 215 216 216 215 215 214 215 216 216 216 216 216 216 215 215 215 215 215 215 214 215 214 214 215 215 216 216 215 215 214 215
CO* 6100 4150 6100 6100 6100 6100 4150 4150 6100 6100 6100 6100 4150 4150 6100 6100 6100 6100 4150 4150 4150 4150 4150 4150 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 4150 4150 6100 6100 6100 6100
18KW N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
27KW N/A N/A N/A N/A N/A N/A N/A N/A 6100 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 6100 N/A 6100 6100 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 6100 N/A N/A N/A
36KW 4150 4150 6100 6100 6100 6100 4150 4150 6100 6100 6100 6100 4150 4150 6100 6100 6100 6100 4150 4150 4150 4150 4150 4150 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 4150 4150 6100 6100 6100 6100
54KW 3250 3250 6100 6100 6100 6100 3250 3250 6100 6100 6100 6100 3250 3250 6100 6100 6100 6100 3250 3250 3250 3250 3250 3250 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 3250 3250 6100 6100 6100 6100
72KW N/A N/A N/A N/A N/A N/A 3250 3250 4150 4150 6100 6100 3250 3250 4150 4150 6100 6100 3250 3250 3250 3250 3250 3250 4150 4150 4150 4150 4150 4150 6100 6100 6100 6100 6100 6100 3250 3250 4150 4150 6100 6100
CO* 4100 6125 4050 4060 4045 4045 6110 6125 4060 4060 4045 4050 6125 6125 4060 4060 4045 4050 6125 6125 6125 6125 6125 6125 4060 4060 4060 4060 4060 4060 4050 4050 4050 4050 4050 4050 6125 6125 4060 4070 4050 4050
18KW N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
27KW N/A N/A N/A N/A N/A N/A N/A N/A 4060 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 4060 N/A 4060 4060 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 4060 N/A N/A N/A
36KW 4150 4150 4070 4070 4060 4060 4150 4150 4070 4070 4060 4060 4150 4150 4070 4070 4060 4060 4150 4150 4150 4150 4150 4150 4070 4070 4070 4070 4070 4070 4060 4060 4060 4060 4060 4060 4150 4150 4070 4070 4060 4060
54KW 3200 3200 4100 4100 4080 4080 3200 3200 4100 4100 4080 4080 3200 3200 4100 4100 4080 4080 3200 3200 3200 3200 3200 3200 4100 4100 4100 4100 4100 4100 4080 4080 4080 4080 4080 4080 3200 3200 4100 4100 4080 4080
72KW N/A N/A N/A N/A N/A N/A 3250 3250 6125 6125 4100 4100 3250 3250 6125 6125 4100 4100 3250 3250 3250 3250 3250 3250 6125 6125 6125 6125 6125 6125 4100 4100 4100 4100 4100 4100 3250 3250 6125 6125 4100 4100
FACTORY INSTALLED OPTIONS (FIOPS) ALL FACTORY INSTALLED OPTIONS ARE BUILT-TO-ORDER. CHECK ORDER SERVICES FOR ESTIMATED PRODUCTION CYCLE.
Unit model # changes to "F" in 2nd digit, indicating desire for factory installed options (unit nameplate will still reflect standard model #, i.e. TCD). Unit mounted disconnect and circuit breakers are mutually exclusive of each other. Through-the-base electrical option must be ordered with either unit mounted disconnect or circuit breaker. When adding heat, must order Trane Electric Heat. When ordering economizer ("A" in 10th digit), TCI ("F" in 10th digit), or economizer and TCI ("G" in 10th digit) use line with m odel number with "0" in 10th digit for FIOP selections; when ordering oversized motor ("B" in 10th digit) or oversized motor & economizer ("C" in 10th digit) uses line with model number with "B" in 10th digit for FIOP selections. When ordering thermal expansion valve ("H" in 10th digit) with economizer ("L" in 10th digit) use line with model number with "H" in the 10th digit for FIOP selections; when ordering thermal expansion valve with oversized motor ("J" in 10th digit) or oversized motor & economizer ("K" in 10th digit) uses line with model number with "J" in 10th digit for FIOP selections. (5) High efficiency motors can be factory installed on downflow and horizontal units unless noted. When ordering horizontal units with high efficiency motors, unit model # changes to "H" in 3rd digit. * Cooling Only
CO* 18KW 27KW 36KW 54KW 72KW 213 N/A N/A 215 216 216 213 N/A N/A 214 214 215 213 N/A N/A 214 214 215 213 N/A N/A 215 216 216 213 N/A 214 214 214 215 213 N/A N/A 214 214 215
18KW 27KW N/A N/A N/A N/A N/A N/A N/A N/A N/A 6100 N/A N/A
54KW 72KW 3250 3250 6100 4150 6100 6100 3250 3250 6100 4150 6100 6100
54KW 72KW 3200 3250 4100 6125 4080 4100 3200 3250 4100 6125 4080 4100
Unit model # changes to "F" in 2nd digit, indicating desire for factory installed options (unit nameplate will still reflect standard model #, i.e. TCD). Unit mounted disconnect and circuit breakers are mutually exclusive of each other. Through-the-base electrical option must be ordered with either unit mounted disconnect or circuit breaker. When adding heat, must order Trane Electric Heat. When ordering economizer ("A" in 10th digit), TCI ("F" in 10th digit), or economizer and TCI ("G" in 10th digit) use line with m odel number with "0" in 10th digit for FIOP selections; when ordering oversized motor ("B" in 10th digit) or oversized motor & economizer ("C" in 10th digit) uses line with model number with "B" in 10th digit for FIOP selections. When ordering thermal expansion valve ("H" in 10th digit) with economizer ("L" in 10th digit) use line with model number with "H" in the 10th digit for FIOP selections; when ordering thermal expansion valve with oversized motor ("J" in 10th digit) or oversized motor & economizer ("K" in 10th digit) uses line with model number with "J" in 10th digit for FIOP selections. (5) High efficiency motors can be factory installed on downflow and horizontal units unless noted. When ordering horizontal units with high efficiency motors, unit model # changes to "H" in 3rd digit. * Cooling Only
FIOP 9
ALL FACTORY INSTALLED OPTIONS ARE BUILT-TO-ORDER. CHECK ORDER SERVICES FOR ESTIMATED PRODUCTION CYCLE.
Accessories:
Model Number Description Switches FIYDFPS005A Clogged Filter Switch FIYDFPS006A Fan Failure Switch Economizer Actuator Logic Module FIYLGCM001A Enthalpy Kits Economizer Actuator Logic Module
Economizer Actuator Logic Module is required with FIOPS (Factory Installed Options) Enthalpy and Novar Controls.
Must select Economizer Actuator Logic Module (FIYLGCM001A) in order to configure and price a Voyager unit. This module does not need to be selected when ordering the field installed accessory.
FIYENTH007A Reference Enthalpy FIYENTH008A Comparative Enthalpy TCI FIYICSI004B Trane Communication Interface LCI FIYLTCI003B LonTalk Interface Discharge Air Sensing Kit FIYTUBE008A Discharge Air Sensing Kit FIYTUBE009A Discharge Air Sensing Kit Tool-less Condenser Hail Guard FIYGARD001B Tool-less Condenser Hail Guard FIYGARD002B Tool-less Condenser Hail Guard FIYGARD003A Tool-less Condenser Hail Guard FIYGARD005A Tool-less Condenser Hail Guard Novar Controls
Downflow Units w/A,C or G in 10th Digit Downflow Units w/A,C or G in 10th Digit YC*150-301** YC*150-301
Used for true discharge air sensing in heating models. Functional only with ReliaTelTM Options Module (FIYABRD002B).
The Novar control option includes the following factory installed and wired devices: Novar ETM-2024 rooftop controller, fan proving switch, clogged filter or unit shutdown switch, Cool 1,Cool 2, Heat switch and discharge air sensor (Novar# DTS-30,20-170F) (Downflow only). NOTE: Option cannot be ordered in conjunction with Factory Installed Smoke Detector option. Must select Economizer Actuator Logic Module (FIYLGCM001A) in order to configure and price a Voyager unit. This module does not need to be selected when ordering the field installed accessory. Novar Controls with an economizer in the 10th digit (Digit 10=A,C,G,K,L,N,R) will also be required to select the Economizer Actuator Logic Module.
FIYCNTL013A Novar Control, 208-230V FIYCNTL015A Novar Control, 460 & 575 V Novar Return Air Sensor FIYNRAS001A Return Air Sensor 2" Pleated Filters FIYPLTD001A 2" Pleated Filters FIYPLTD002A 2" Pleated Filters FIYPLTD003A 2" Pleated Filters Novar Controls-3051
YCD150-301*3 YCD150-301*4,W
This option consists of the Novar return air sensor (Novar # WTS-10) that is wired and shipped in the return air section of the unit. The sensor ships with approximately 15' of extra wire for dropping down the return air duct (downflow only).
The Novar control option includes the following factory installed and wired devices: Novar 3051 rooftop controller, fan proving switch, clogged filter or unit shutdown switch, and discharge air sensor (Novar # DTS-30, 20-170F) (downflow only). NOTE: This option can be ordered in conjunction with factory installed Smoke Detector option. It cannot be ordered in conjunction with with economizer, either field or factory installed.Must select Economizer Actuator Logic Module (FIYLGCM001A) in order to configure and price a Voyager unit. This module does not need to be selected when ordering the field installed accessory. Novar Controls with an economizer in the 10th digit (Digit 10=A,C,G,K,L,N,R) will also be required to select the Economizer Actuator Logic Module.
FIYCNTL016A Novar Control, 460 and 575V FIYCNTL017A Novar Control, 208-230V FIYCNTL018A Novar Control, 460 and 575V FIYCNTL019A Novar Control, 208-230V Novar Zone Sensor FIYNZSR001A Novar Zone Sensor for Novar 3051
This option consista of Novar Zone Sensor (Novar #WTS-SOS) used with Novar 3051 Controls.
Accessories:
Model Number Description Through The Base Gas Piping FIYTBUG202A1 Through-the-Base Gas Piping FIYTBUG203A1 FIYTBUG205A2 Through-the-Base Gas Piping Through-the-Base Gas Piping
FIYTBUG206A2 Through-the-Base Gas Piping Convenience Outlet FIYCOPO201A Powered, 120v. Convenience Outlet, 230v. FIYCOPO202A Powered, 120v. Convenience Outlet, 460v. FIYCOPO205A Powered, 120v. Convenience Outlet, 575v. FIYCOUP201A Unpowered, 115v. Convenience Outlet Filter & Control Access
Used with only downflow units.
Must be ordered with Through-the Base Electrical option and either Unit Mounted Disconnect or Circuit Breaker (downflow only).
FIYHNGE004A Hinged Filter/Evap. and Comp./Control Access Door FIYHNGE005A Hinged Filter/Evap. and Comp./Control Access Door FIYHNGE008A Hinged Filter/Evap. and Comp./Control Access Door FIYHNGE009A Hinged FIlter/Evap. and Comp./Control Access Door Disconnect Switch FIYUDC4150A Unit Mounted Disconnect Switch FIYUDC6100A Unit Mounted Disconnect Switch High Efficiency Motors
Can be used on downflow or horizontal units unless specified on matrix sheets.
Must be used with Through-the Base Electrical option (downflow only). Cannot be fused.
FIYHEMT001A 2 HP High Effic. Motor (86.5 Eff.)(208-230/460/60/3) FIYHEMT002A 2 HP High Effic. Motor (86.5 Eff. (575/60/3) FIYHEMT003A 3 HP High Effic. Motor (89.5 Eff.)(208-230/60/3) FIYHEMT004A 3 HP High Effic. Motor (89.5 Eff.)(460/60/3) FIYHEMT005A 3 HP High Effic. Motor (89.5 Eff.)(575/60/3) FIYHEMT006A 5 HP High Effic. Motor (91.0 Eff.)(208-230/60/3) FIYHEMT007A 5 HP High Effic. Motor (91.0 Eff.)(460/60/3) FIYHEMT008A 5 HP High Effic. Motor (91.0 Eff.)(575/60/3) FIYHEMT009A 7 HP High Effic. Motor (90.2 Eff.)(208-230/60/3) FIYHEMT010A 7 HP High Effic. Motor (90.2 Eff.)(460/60/3) FIYHEMT011A 7 HP High Effic. Motor (90.2 Eff.)(575/60/3) Stainless Steel Heat Exchanger
Can be used on all downflow or horizontal units.
Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets
FIYSSHX001A FIYSSHX002A
150 MBH Stainless Steel Heat Exchanger 250 MBH Stainless Steel Heat Exchanger
FIYSSHX003A FIYSSHX004A
350 MBH Stainless Steel Heat Exchanger 400 MBH Stainless Steel Heat Exchanger
YCD/H150D,151C Low Heat YCD/H150D,151C High Heat YCD/H155B,175C,180B,181C, 200B,210C,211C,240B,241C, 250B,300B and 301C Low Heat YCD/H155B,175C,180B,181C 210C, 211C High Heat YCD/H200B,240B,241C,250B, 300B,301C High Heat
Must order when ordering through-the-base electrical or through-the-base access option (downflow only). Order when not ordering through-the-base electrical or through-the-base access option (downflow only).
FIOP 11
Accessories:
Model Number Circuit Breaker Description
FIYUCB3125A Unit Mounted Circuit Breaker FIYUCB3150A Unit Mounted Circuit Breaker FIYUCB3175A Unit Mounted Circuit Breaker FIYUCB3200A Unit Mounted Circuit Breaker FIYUCB3225A Unit Mounted Circuit Breaker FIYUCB3250A Unit Mounted Circuit Breaker FIYUCB4015A Unit Mounted Circuit Breaker FIYUCB4020A Unit Mounted Circuit Breaker FIYUCB4025A Unit Mounted Circuit Breaker FIYUCB4030A Unit Mounted Circuit Breaker FIYUCB4035A Unit Mounted Circuit Breaker FIYUCB4040A Unit Mounted Circuit Breaker FIYUCB4045A Unit Mounted Circuit Breaker FIYUCB4050A Unit Mounted Circuit Breaker FIYUCB4060A Unit Mounted Circuit Breaker FIYUCB4070A Unit Mounted Circuit Breaker FIYUCB4080A Unit Mounted Circuit Breaker FIYUCB4090A Unit Mounted Circuit Breaker FIYUCB4100A Unit Mounted Circuit Breaker FIYUCB4110A Unit Mounted Circuit Breaker FIYUCB4125A Unit Mounted Circuit Breaker FIYUCB4150A Unit Mounted Circuit Breaker FIYUCB6110A Unit Mounted Circuit Breaker FIYUCB6125A Unit Mounted Circuit Breaker Through the Base Electrical FIYTBUE101A Through-the-Base Electrical Option FIYTBUE105A Through-the-Base Electrical Option FIYTBUE109A Through-the-Base Electrical Option FIYTBUE201A Through-the-Base Electrical Option FIYTBUE206A Through-the-Base Electrical Option FIYTBUE207A Through-the-Base Electrical Option FIYTBUE211A Through-the-Base Electrical Option FIYTBUE212A Through-the-Base Electrical Option Black Epoxy Coated Condenser Coil FIYCOIL205A Black Epoxy Coated Condenser Coil FIYCOIL206A Black Epoxy Coated Condenser Coil FIYCOIL209A Black Epoxy Coated Condenser Coil FIYCOIL210A Black Epoxy Coated Condenser Coil
Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets
Must be used with either factory installed Unit Mounted Disconnect Switch or Unit Mounted Circuit Breaker (downflow only). If no factory installed Unit Mounted Disconnect Switch or Unit Mounted Circuit Breaker is required, order the Through the Base Utility Access (FIYTBUA***) from page FIOP13
Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets YCD/YCH150 YCD/YCH151,180,210 YCD/YCH181,211,241,301,240 YCD/YCH300
FIOP 12
Accessories:
Model Number Description TM ReliaTel Options Module
FIYABRD002B is required when ordering the following accessories: Clogged Filter Switch (FIYDFPS005A/BAYDFPS005A), Fan Fail Switch (FIYDFPS006A/BAYDFPS006A), Discharge Air Sensing Kit (FIYTUBE008A,FIYTUBE009A, BAYTUBE008A, BAYTUBE009A), Frostat (FIYLOAM023A, BAYLOAM023A), Ventilation Override (must order BAYVNOR002B), Smoke Detector (FIYSMDT).
FIYABRD002B
FIYSMDT221A FIYSMDT223A
Return Air Smoke Detector for downflow units without economizer 12 FIYSMDT222A Return Air Smoke Detector YCD150,151,180,210 w/FIYABRD002B FIYSMDT224A Return Air Smoke Detector YCD181,211,240,241,300,301
w/FIYABRD002B
Supply and Return Air Smoke Detectors for downflow units with economizer
Option cannot be ordered in conjunction with field installed economizer.
FIYSMDT226A FIYSMDT229A
Supply and Return Air Smoke Detector Supply and Return Air Smoke Detector
YCD150,151,180,210
w/FIYABRD002B
YCD181,211,240,241,300,301
w/FIYABRD002B
Supply and Return Air Smoke Detectors for downflow units without economizer FIYSMDT227A Supply and Return Air Smoke Detector YCD150,151,180,210
w/FIYABRD002B
FIYSMDT230A
YCD181,211,240,241,300,301
w/FIYABRD002B
The return air smoke detector may not fit up or work properly on the Voyager units when used in conjunction with 3rd party accessories (such as bolt on heat wheels, economizers, and power exhaust). Do not order the return air smoke detectors when using this type of accessory.
2 Smoke Detectors available for downflow units only.
Through the Base Utilities Access Through the Base Utilities Access
Frostat
w/FIYABRD002B
FIOP 13
FIOP 14
Model Number (1)(4) * L or H Heat YFD150D3*0B YFD150D3*BB YFD150D4*0B YFD150D4*BB YFD150DW*0B YFD150DW*BB YFD151C3*0B YFD151C3*BB YFD151C4*0B YFD151C4*BB YFD151CW*0B YFD151CW*BB YFD151C3*HB YFD151C3*JB YFD151C4*HB YFD151C4*JB YFD151CW*HB YFD151CW*JB YFD180B3*0H YFD180B3*BH YFD180B4*0H YFD180B4*BH YFD180BW*0H YFD180BW*BH YFD181C3*0C YFD181C3*BC YFD181C3*MC YFD181C3*NC YFD181C3*PC YFD181C3*RC YFD181C4*0C YFD181C4*BC YFD181C4*MC YFD181C4*NC YFD181C4*PC YFD181C4*RC YFD181CW*0C YFD181CW*BC YFD181CW*MC YFD181CW*NC YFD181CW*PC YFD181CW*RC YFD181C3*HC YFD181C3*JC YFD181C4*HC YFD181C4*JC YFD181CW*HC YFD181CW*JC 003 006 004 007 005 008 003 006 004 007 005 008 003 006 004 007 005 008 003 006 004 007 005 008 003 006 003 003 006 006 004 007 004 004 007 007 005 008 005 005 008 008 003 006 004 007 005 008 206 206 206 206 206 206 206 206 206 206 206 206 206 206 206 206 206 206 206 206 206 206 206 206 212 212 212 212 212 212 211 211 211 211 211 211 211 211 211 211 211 211 212 212 211 211 211 211 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 4080 4080 4040 4040 4030 4035 4080 4090 4040 4040 4030 4035 4070 4080 4035 4040 4030 4030 4090 4100 4050 4050 4040 4040 4090 4100 4090 4090 6100 6100 4050 4050 4045 4045 4050 4050 4040 4040 4035 4035 4040 4040 4090 4090 4050 4050 4040 4040
ALL FACTORY INSTALLED OPTIONS ARE BUILT-TO-ORDER. Unit model # changes to "F" in 2nd digit, indicating desire for factory installed options (unit nameplate will still reflect standard model #, i.e. YCD). CHECK ORDER SERVICES FOR ESTIMATED PRODUCTION CYCLE. Unit mounted disconnect and circuit breakers are mutually exclusive of each other. Through-the-base electrical option must be ordered with either unit mounted disconnect or circuit breaker. When ordering economizer ("A" in 10th digit), TCI ("F" in 10th digit), or economizer and TCI ("G" in 10th digit) use line with m odel number with "0" in 10th digit for FIOP selections; when ordering oversized motor ("B" in 10th digit) or oversized motor & economizer ("C" in 10th digit) uses line with model number with "B" in 10th digit for FIOP selections. When ordering thermal expansion valve ("H" in 10th digit) with economizer ("L" in 10th digit) use line with model number with "H" in the 10th digit for FIOP selections; when ordering thermal expansion valve with oversized motor ("J" in 10th digit) or oversized motor & economizer ("K" in 10th digit) uses line with model number with "J" in 10th digit for FIOP selections. (5) High efficiency motors can be factory installed on downflow and horizontal units unless noted. When ordering horizontal units with high efficiency motors, unit model # changes to "H" in 3rd digit.
FIOP 15
* L or H Heat YFD210C3*0E YFD210C3*BE YFD210C4*0E YFD210C4*BE YFD210CW*0E YFD210CW*BE YFD211C3*0C YFD211C3*BC YFD211C4*0C YFD211C4*BC YFD211CW*0C YFD211CW*BC YFD240B3*0J YFD240B3*BJ YFD240B4*0J YFD240B4*BJ YFD240BW*0J YFD240BW*BJ YFD241C3*0C YFD241C3*BC YFD241C3*MC YFD241C3*NC YFD241C3*PC YFD241C3*RC YFD241C4*0C YFD241C4*BC YFD241C4*MC YFD241C4*NC YFD241C4*PC YFD241C4*RC YFD241CW*0C YFD241CW*BC YFD241CW*MC YFD241CW*NC YFD241CW*PC YFD241CW*RC YFD241C3*HC YFD241C3*JC YFD241C4*HC YFD241C4*JC YFD241CW*HC YFD241CW*JC 006 009 007 010 008 011 006 009 007 010 008 011 006 009 007 010 008 011 006 009 006 006 009 009 007 010 007 007 010 010 008 011 008 008 011 011 006 009 007 010 008 011 206 206 206 206 206 206 212 212 211 211 211 211 212 212 211 211 211 211 212 212 212 212 212 212 211 211 211 211 211 211 211 211 211 211 211 211 212 212 211 211 211 211 6100 4150 6100 6100 6100 6100 4150 4150 6100 6100 6100 6100 4150 4150 6100 6100 6100 6100 4150 4150 4150 4150 4150 4150 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 6100 4150 4150 6100 6100 6100 6100 4100 4125 4050 4060 4045 4045 4110 4125 4060 4060 4045 4050 4125 4125 4060 4060 4045 4050 4125 4125 6125 6125 6125 6125 4060 4060 4060 4060 4060 4060 4050 4050 4050 4050 4050 4050 4125 4125 4060 4070 4050 4050
FACTORY INSTALLED OPTIONS (FIOPS) (1) Unit model # changes to "F" in 2nd digit, indicating desire for factory installed options (unit nameplate will still reflect standard model #, i.e. YCD). ALL FACTORY INSTALLED OPTIONS ARE BUILT-TO-ORDER. CHECK ORDER SERVICES FOR ESTIMATED PRODUCTION CYCLE. (2) Unit mounted disconnect and circuit breakers are mutually exclusive of each other. (3) Through-the-base electrical option must be ordered with either unit mounted disconnect or circuit breaker. (4) When ordering economizer ("A" in 10th digit), TCI ("F" in 10th digit), or economizer and TCI ("G" in 10th digit) use line with m odel number with "0" in 10th digit for FIOP selections; when ordering oversized motor ("B" in 10th digit) or oversized motor & economizer ("C" in 10th digit) uses line with model number with "B" in 10th digit for FIOP selections. When ordering thermal expansion valve ("H" in 10th digit) with economizer ("L" in 10th digit) use line with model number with "H" in the 10th digit for FIOP selections; when ordering thermal expansion valve with oversized motor ("J" in 10th digit) or oversized motor & economizer ("K" in 10th digit) uses line with model number with "J" in 10th digit for FIOP selections. (5) High efficiency motors can be factory installed on downflow and horizontal units unless noted. When ordering horizontal units with high efficiency motors, unit model # changes to "H" in 3rd digit.
009
YFD300B4*0H YFD300BW*0H
010 011
YFD301C3*0C
009
YFD301C4*0C YFD301CW*0C
010 011
FIOP 16
FACTORY INSTALLED OPTIONS (FIOPS) (1) Unit model # changes to "F" in 2nd digit, indicating desire for factory installed options (unit nameplate will still reflect standard model #, i.e. YCD). (2) Unit mounted disconnect and circuit breakers are mutually exclusive of each other. (3) Through-the-base electrical option must be ordered with either unit mounted disconnect or circuit breaker. (4) When ordering economizer ("A" in 10th digit), TCI ("F" in 10th digit), or economizer and TCI ("G" in 10th digit) use line with m odel number with "0" in 10th digit for FIOP selections; when ordering oversized motor ("B" in 10th digit) or oversized motor & economizer ("C" in 10th digit) uses line with model number with "B" in 10th digit for FIOP selections. When ordering thermal expansion valve ("H" in 10th digit) with economizer ("L" in 10th digit) use line with model number with "H" in the 10th digit for FIOP selections; when ordering thermal expansion valve with oversized motor ("J" in 10th digit) or oversized motor & economizer ("K" in 10th digit) uses line with model number with "J" in 10th digit for FIOP selections. (5) High efficiency motors can be factory installed on downflow and horizontal units unless noted. When ordering horizontal units with high efficiency motors, unit model # changes to "H" in 3rd digit.
ALL FACTORY INSTALLED OPTIONS ARE BUILT-TO-ORDER. CHECK ORDER SERVICES FOR ESTIMATED PRODUCTION CYCLE.
Accessories:
Model Number Description Switches FIYDFPS005A Clogged Filter Switch FIYDFPS006A Fan Failure Switch Economizer Actuator Logic Module FIYLGCM001A Enthalpy Kits Economizer Actuator Logic Module
Economizer Actuator Logic Module is required with FIOPS (Factory Installed Options) Enthalpy.
Must select Economizer Actuator Logic Module (FIYLGCM001A) in order to configure and price a Voyager unit. This module does not need to be selected when ordering the field installed accessory.
FIYENTH007A FIYENTH008A
Downflow Units w/A,C or G in 10th Digit Downflow Units w/A,C or G in 10th Digit WC*150-240** WC*150-240
TCI FIYICSI004B Trane Communication Interface LCI FIYLTCI003B LonTalk Interface Discharge Air Sensing Kit
FIYTUBE008A Discharge Air Sensing Kit FIYTUBE009A Discharge Air Sensing Kit Tool-less Condenser Hail Guard FIYGARD004A Tool-less Condenser Hail Guard FIYGARD003A Tool-less Condenser Hail Guard Convenience Outlet FIYCOPO201A FIYCOPO202A FIYCOPO205A FIYCOUP201A 2" Pleated Filters FIYPLTD001A FIYPLTD002A FIYPLTD003A Powered, 120v. Convenience Outlet, 230v Powered, 120v. Convenience Outlet, 460v. Powered, 120v. Convenience Outlet, 575v. Unpowered, 115v. Convenience Outlet 2" Pleated Filters 2" Pleated Filters 2" Pleated Filters
Used for true discharge air sensing in models with electric heat. Functional only with ReliaTelTM Options Module (FIYABRD002B).
Must be used with Through-the-Base Electrical option and either Unit Mounted Disconnect or Circuit Breaker (downflow only).
FIOP 17
Used With
FIYHNGE004A Hinged Filter/Evap. and Comp./Control Access Door FIYHNGE009A Hinged Filter/Evap. and Comp./Control Access Door Disconnect Switch Cannot be fused.
Must be used with Through-the-Base Electrical option (downflow only).
WCD150-180 WCD240
FIYUDC4100A Unit Mounted Disconnect Switch FIYUDC4150A Unit Mounted Disconnect Switch FIYUDC3250A Unit Mounted Disconnect Switch FIYUDC6100A Unit Mounted Disconnect Switch High Efficiency Motors
Can be used on downflow or horizontal units unless specified on matrix sheets.
Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets
FIYHEMT001A FIYHEMT002A FIYHEMT003A FIYHEMT004A FIYHEMT005A FIYHEMT006A FIYHEMT007A FIYHEMT008A FIYHEMT009A FIYHEMT010A FIYHEMT011A Circuit Breaker FIYUCB4015A FIYUCB4020A FIYUCB4025A FIYUCB4030A FIYUCB4035A FIYUCB4040A FIYUCB4045A FIYUCB4050A FIYUCB4060A FIYUCB4070A FIYUCB4080A FIYUCB4090A FIYUCB4100A FIYUCB4110A FIYUCB4125A FIYUCB4150A FIYUCB3175A FIYUCB3200A FIYUCB3225A FIYUCB3250A FIYUCB6110A FIYUCB6125A
2 HP High Effic. Motor (86.5 Eff.)(208-230/460/60/3) 2 HP High Effic. Motor (86.5 Eff.)(575/60/3) 3 HP High Effic. Motor (89.5 Eff.)(208-230/60/3) 3 HP High Effic. Motor (89.5 Eff.)(460/60/3) 3 HP High Effic. Motor (89.5 Eff.)(575/60/3) 5 HP High Effic. Motor (91.0 Eff.)(208-230/60/3) 5 HP High Efficiency Motor (91.0 Eff.)(460/60/3) 5 HP High Efficiency Motor (91.0 Eff.)(575/60/3) 7 HP High Efficiency Motor (90.2 Eff.)(208-230/60/3) 7 HP High Efficiency Motor (90.2 Eff.)(460/60/3) 7 HP High Efficiency Motor (90.2 Eff.)(575/60/3)
Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets
Unit Mounted Circuit Breaker Unit Mounted Circuit Breaker Unit Mounted Circuit Breaker Unit Mounted Circuit Breaker Unit Mounted Circuit Breaker Unit Mounted Circuit Breaker Unit Mounted Circuit Breaker Unit Mounted Circuit Breaker Unit Mounted Circuit Breaker Unit Mounted Circuit Breaker Unit Mounted Circuit Breaker Unit Mounted Circuit Breaker Unit Mounted Circuit Breaker Unit Mounted Circuit Breaker Unit Mounted Circuit Breaker Unit Mounted Circuit Breaker Unit Mounted Circuit Breaker Unit Mounted Circuit Breaker Unit Mounted Circuit Breaker Unit Mounted Circuit Breaker Unit Mounted Circuit Breaker Unit Mounted Circuit Breaker
Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets
FIOP 18
Accessories:
Model Number Description Through the Base Electrical
FIYTBUE102A FIYTBUE103A FIYTBUE104A FIYTBUE106A FIYTBUE107A FIYTBUE108A FIYTBUE202A FIYTBUE203A FIYTBUE204A FIYTBUE205A FIYTBUE207A FIYTBUE208A FIYTBUE209A FIYTBUE210A FIYTBUE213A FIYTBUE214A FIYTBUE215A FIYTBUE216A Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option Through-the-Base Electrical Option
Must be used with factory installed Unit Mounted Disconnect Switch or Unit Mounted Circuit Breaker (downflow only). When adding heat, must order Trane Electric Heat.If no factory installed Unit Mounted Disconnect Switch or Unit Mounted Circuit Breaker is required, order the Through the Base Utility Access Option(FIYTBUA****) from page FIOP21
Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets Consult Matrix Sheets
Electric Heat
Must be factory installed when using with Through-the-Base Electrical option.
FIYHTRP105A FIYHTRP110A FIYHTRP114A FIYHTRP118A FIYHTRP306A FIYHTRP312A FIYHTRP318A FIYHTRP323A FIYHTRP406A FIYHTRP412A FIYHTRP418A FIYHTRP423A FIYHTRPW06A FIYHTRPW12A FIYHTRPW18A FIYHTRPW23A FIDHTRA327B FIDHTRA336B FIDHTRB309B FIDHTRB318B FIDHTRD318A FIDHTRD336A FIDHTRD354A FIDHTRK318A FIDHTRK336A FIDHTRK354A FIDHTRL336A FIDHTRL354A FIDHTRK372A FIDHTRA409B FIDHTRA418B FIDHTRA427B
Factory Installed 6 KW Electric Heat Factory Installed 10 KW Electric Heat Factory Installed 14 KW Electric Heat Factory Installed 18 KW Electric Heat Factory Installed 6 KW Electric Heat Factory Installed 12 KW Electric Heat Factory Installed 18 KW Electric Heat Factory Installed 23 KW Electric Heat Factory Installed 6 KW Electric Heat Factory Installed 12 KW Electric Heat Factory Installed 18 KW Electric Heat Factory Installed 23 KW Electric Heat Factory Installed 6 KW Electric Heat Factory Installed 12 KW Electric Heat Factory Installed 18 KW Electric Heat Factory Installed 23 KW Electric Heat Factory Installed 27 KW Electric Heat Factory Installed 36 KW Electric Heat Factory Installed 9 KW Electric Heat Factory Installed 18 KW Electric Heat Factory Installed 18 KW Electric Heat Factory Installed 36 KW Electric Heat Factory Installed 54 KW Electric Heat Factory Installed 18 KW Electric Heat Factory Installed 36 KW Electric Heat Factory Installed 54 KW Electric Heat Factory Installed 36 KW Electric Heat Factory Installed 54 KW Electric Heat Factory Installed 72 KW Electric Heat Factory Installed 9 KW Electric Heat Factory Installed 18 KW Electric Heat Factory Installed 27 KW Electric Heat
See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets
FIOP 19
Accessories:
Model Number
FIDHTRA436B FIDHTRC418A FIDHTRD418A FIDHTRD436A FIDHTRD454A FIDHTRK436A FIDHTRK454A FIDHTRL436A FIDHTRL454A FIDHTRK472A FIDHTRAW18B FIDHTRAW27B FIDHTRCW18A FIDHTRCW36A FIDHTRCW54A FIDHTRDW18A FIDHTRDW54A FIDHTRKW36A FIDHTRKW54A FIDHTRLW36A FIDHTRMW36A FIDHTRKW72A FIHHTRA327B FIHHTRA336B FIHHTRB309B FIHHTRB318B FIHHTRD318A FIHHTRD336A FIHHTRD354A FIHHTRM318A FIHHTRM336A FIHHTRM354A FIHHTRN336A FIHHTRN354A FIHHTRN372A FIHHTRA409B FIHHTRA418B FIHHTRA427B FIHHTRA436B FIHHTRM418A FIHHTRD418A FIHHTRM436A FIHHTRM454A FIHHTRN436A FIHHTRN454A FIHHTRN472A FIHHTRAW18B FIHHTRAW27B FIHHTRMW18A FIHHTRMW36A FIHHTRCW54A FIHHTREW36A FIHHTRMW54A FIHHTRNW36A FIHHTRNW54A FIHHTRNW72A
Used With
See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets See Unit Price Sheets
FIOP 20
Accessories:
Model Number Description
FIHHTRMW54A Factory Installed 54 KW Electric Heat FIHHTRNW54A Factory Installed 54 KW Electric Heat FIHHTRNW72A Factory Installed 72 KW Electric Heat FIHHTRN318A Factory Installed 18 KW Electric Heat FIHHTRNW18A Factory Installed 18 KW Electric Heat FIHHTRP336A Factory Installed 36 KW Electric Heat FIHHTRP436A Factory Installed 36 KW Electric Heat FIHHTRP454A Factory Installed 54 KW Electric Heat FIHHTRP454A Factory Installed 54 KW Electric Heat FIHHTRQW54A Factory Installed 54 KW Electric Heat FIHHTRP418A Factory Installed 18 KW Electric Heat FIHHTRQW36A Factory Installed 18 KW Electric Heat Black Epoxy Coated Condenser Coil FIYCOIL205A Black Epoxy Coated Condenser Coil FIYCOIL206A Black Epoxy Coated Condenser Coil FIYCOIL209A Black Epoxy Coated Condenser Coil
FIYABRD002B ReliaTelTM Options Module All Voyager Units Return Air Smoke Detector for downflow units with economizer Option cannot be ordered in conjunction with field installed economizer. FIYSMDT221A Return Air Smoke Detector WCD150,180B w/FIYABRD002B FIYSMDT223A Return Air Smoke Detector WCD240B w/FIYABRD002B Return Air Smoke Detector for downflow units without economizer FIYSMDT222A Return Air Smoke Detector FIYSMDT224A Return Air Smoke Detector Supply Air Smoke Detector for downflow units WCD150,180B w/FIYABRD002B WCD240B w/FIYABRD002B
FIYSMDT225A Supply Air Smoke Detector WCD150B-180B w/FIYABRD002B FIYSMDT228A Supply Air Smoke Detector WCD240B w/FIYABRD002B Supply and Return Air Smoke Detectors for downflow units with economizer Option cannot be ordered in conjunction with field installed economizer. FIYSMDT226A Supply and Return Air Smoke Detector WCD150,180B w/FIYABRD002B FIYSMDT229A Supply and Return Air Smoke Detector WCD240B w/FIYABRD002B Supply and Return Air Smoke Detectors for downflow units without economizer FIYSMDT227A FIYSMDT230A Supply and Return Air Smoke Detector Supply and Return Air Smoke Detector WCD150,180B w/FIYABRD002B WCD240B w/FIYABRD002B
1 The return air smoke detector may not fit up or work properly on the Voyager units when used in conjunction with 3rd party accessories (such as bolt on heat wheels, economizers, and power exhaust). Do not order the return air smoke detectors when using this type of accessory. Smoke Detectors available for downflow units only.
FIYTBUA205A FIYTBUA207A
Through the Base Utilities Access Through the Base Utilities Access
WCD150,180B3,B4 WCD240,300B3,B4
FIOP 21
18KW 36KW 54KW 72KW 209 210 210 N/A 209 210 210 N/A 208 208 209 N/A 208 208 209 N/A 208 208 208 N/A 208 208 208 N/A
18KW 36KW 54KW 72KW 4150 3250 3250 N/A 4150 3250 3250 N/A 6100 6100 4150 N/A 6100 6100 4150 N/A 6100 6100 6100 N/A 6100 6100 6100 N/A
18KW 36KW 54KW 72KW 6125 3175 3250 N/A 4150 3200 3250 N/A 4060 4090 6125 N/A 4070 4090 6125 N/A 4050 4070 4090 N/A 4050 4080 4100 N/A
FIOP 22
Unit model # changes to "F" in 2nd digit, indicating desire for factory installed options (unit nameplate will still reflect standard model #, i.e. WCD). Unit mounted disconnect and circuit breakers are mutually exclusive of each other. Through-the-base electrical option must be ordered with either unit mounted disconnect or circuit breaker. When adding heat, must order Trane Electric Heat. When ordering economizer ("A" in 10th digit), TCI ("F" in 10th digit), or economizer and TCI ("G" in 10th digit) use line with model number with "0" in 10th digit for FIOP selections; when ordering oversized motor ("B" in 10th digit) or oversized motor & economizer ("C" in 10th digit) uses line with model number with "B" in 10th digit for FIOP selections. (5) High efficiency motors can be factory installed on downflow and horizontal units unless noted. When ordering horizontal units with high efficiency motors, unit model # changes to "H" in 3rd digit.
WFD180B300G WFD180B30BG WFD180B400G WFD180B40BG WFD180BW00G WFD180BW0BG WFD240B300G WFD240B30BG WFD240B400G WFD240B40BG WFD240BW00G WFD240BW0BG
003 006 004 007 005 008 006 009 007 010 008 011
CO* 207 207 207 207 207 207 213 213 213 213 213 213
18KW 36KW 54KW 72KW 209 210 210 N/A 209 210 NA N/A 208 208 209 N/A 208 209 209 N/A 208 208 209 N/A 208 208 209 N/A N/A 216 216 N/A N/A 216 NA N/A N/A 215 215 N/A N/A 215 215 N/A N/A 214 215 215 N/A 214 215 215
CO* 6100 6100 6100 6100 6100 6100 4150 4150 6100 6100 6100 6100
18KW 36KW 54KW 72KW 4150 3250 3250 N/A 4150 3250 3250 N/A 6100 6100 4150 N/A 6100 6100 4150 N/A 6100 6100 6100 N/A 6100 6100 6100 N/A N/A 3250 NA N/A N/A 3250 NA N/A N/A 4150 4150 N/A N/A 4150 4150 N/A N/A 6100 4150 4150 N/A 6100 4150 4150
CO* 4090 4100 4045 4050 4035 4040 6125 6125 4060 4060 4045 4050
18KW 36KW 54KW 72KW 4150 3200 3250 N/A 4150 3200 3250 N/A 4070 4100 6125 N/A 4070 4100 6125 N/A 4060 4080 4100 N/A 4060 4080 4100 N/A N/A 3225 NA N/A N/A 3225 NA N/A N/A 6110 4150 N/A N/A 6110 4150 N/A N/A 4090 6110 6125 N/A 4090 6110 4150
FIOP 23
Unit model # changes to "F" in 2nd digit, indicating desire for factory installed options (unit nameplate will still reflect standard model #, i.e. WCD). Unit mounted disconnect and circuit breakers are mutually exclusive of each other. Through-the-base electrical option must be ordered with either unit mounted disconnect or circuit breaker. When adding heat, must order Trane Electric Heat. When ordering economizer ("A" in 10th digit), TCI ("F" in 10th digit), or economizer and TCI ("G" in 10th digit) use line with model number with "0" in 10th digit for FIOP selections; when ordering oversized motor ("B" in 10th digit) or oversized motor & economizer ("C" in 10th digit) uses line with model number with "B" in 10th digit for FIOP selections. (5) High efficiency motors can be factory installed on downflow and horizontal units unless noted. When ordering horizontal units with high efficiency motors, unit model # changes to "H" in 3rd digit. * Cooling Only
ALL FACTORY INSTALLED OPTIONS ARE BUILT-TO-ORDER. CHECK ORDER SERVICES FOR ESTIMATED PRODUCTION CYCLE.