WIRE CONNECTION CUSTOMER LINE/LOAD POWER CONNECTION
23
TWISTED PAIR
24
FLANGE DISCONNECT SWITCH (400 AMP) CT4 - GFCT 50:0.025 CT HIGH RESISTANCE RESISTIVELY GROUNDED SYSTEM 150:5 CT AK 9R L2 FU2 9R 2 9 CT2 L3 FU3 9R #6 AWG FLEX (7.5kV) H1 A480T 2E FU4 H2 A480T 2E FU5 #6 AWG FLEX (7.5kV) 10 CT3 13 12 150:5 CT IL SCRB BG BK 1 8 CT1 11 IL 150:5 CT AG IN-LINE CONTACTOR 400A JC-MVC77U034A50-76 IL
BISCR3504030GR PHASE 1 SCR STACK ASSEMBLY. (SAME AS PHASE 2 SCR STACK ASSEMBLY) LOAD - TOP EXIT 2-HOLE (1.75"C-C) LANDING PAD PHASE 2 SCR STACK ASSEMBLY. CK CG SCRA SCRC EK EG SCRE T2 700HP (EST. 93 FLA) 360Hz. 4160 VAC GND T1
L1
L2
L3
GROUND BALL
BUNDLE OF OPTICAL FIBERS (XX DENOTES NUMBER OF FIBERS IN BUNDLE) OPTICAL FIBER (ARROWHEAD POINTS IN DIRECTION OF LIGHT FLOW)
SCRD
DG
DK
SCRF
MOLEX CONNECTOR
31
BK
PHASE 3 SCR STACK ASSEMBLY. (SAME AS PHASE 2 SCR STACK ASSEMBLY) BK 30 25 [O,7] 82 83
TO 120VAC [U,3]
4160VAC
80 120VAC X1 X2
81
76
77
1 kVA
[U,5]
[G,2]
GROUND WIRES ARE ALL #12AWG (MIN.) GREEN WIRE, RUN SEPARATELY TO GROUND LUG POINT. DAISY CHAIN GROUND WIRES. RUN ALL GROUND WIRES A MINIMUM OF FOUR (4) INCHES FROM POWER CABLE AND HEAT SINKS. ALL MV POWER WIRING MUST BE ROUTED SEPARATE FROM LV CONTROL AND GROUND WIRING. MV POWER WIRES MUST CROSS AT 90 TO LV CONTROL WIRE WHERE EVER POSSIBLE. IF MV POWER WIRE MUST RUN PARALLEL TO LV CONTROL WIRE, THERE MUST BE A SEPARATION OF A MINIMUM OF 4".
BP GROUND BUS
BK A
WHT A 8 TB6 9 TB3 10 TB1 #2 AWG FLEX (7.5kV) #2 AWG FLEX (7.5kV) BP 5A CT SIGNAL WIRING TO BE #12AWG. INSTALL HIGH VOLTAGE SLEEVING ON EACH TWISTED PAIR & O/T SWITCH WIRES COMING OFF THE DRIVER BOARD. WHITE DOT/WIRE OF EACH CT MUST FACE TOWARDS LINE VOLTAGE SOURCE. APPLY HIGH VOLTAGE INSULATION AROUND POWER WIRE PASSING THRU CTs. INSULATION MUST EXTEND A MINIMUM 3" PAST EDGES OF CT. ALL AC/DC CONTROL WIRING IS #14AWG TEW105C UNLESS OTHERWISE SPECIFIED. BLUE = +DC RED = AC LIVE WHITE/BLUE = -DC KEYPAD MOUNTING TORQUE: 6 IN. LBS.
X1A
X2A
NORMAL TEST WHT
BIPC-300032-01
R3
R2
R1 86 R6 87 66 67 68 69 78 79 84 85
BK
[U,15]
[U,15]
[G,3]
82
#10 AWG
HC 5 [G,5] 6
#10 AWG
101
? WATT
102
CUSTOMER SUPPLIED
X X
R5
TO LV SECTION [H,7] 54 57 O/T SWITCH ON PHASE #16 AWG RED 1 J3 O/T 2 1 2 J1 3 53 56 O/T SWITCH ON PHASE #16 AWG RED 1 J3 O/T 2 1 2 J1 3 52 55 O/T SWITCH ON PHASE
ATQR10
JUMPER
102 A1 A2
31
[D,16]
32
31
[F,19]
32
10
IL
BP
FU6
MOTOR WINDING
82
83
84
85
24VAC
R4
B
STRIP HEATER 82
THERMOSTAT
X
B
TB7
TB4
TB2
TB5
10
H OS1212-250
102
BK
X
MOUNTED IN LV COMPARTMENT
52
53
51A
57
56
55
LOCATED IN MV SECTION
FU7 10 ATQR10
54
D 52 53 54 57 56 55
BIPC-300047-01
FIBER OPTIC GATE DRIVER CARD
BIPC-300047-01
FIBER OPTIC GATE DRIVER CARD
BIPC-300047-01
FIBER OPTIC GATE DRIVER CARD
H
LED STATUS WITH POWER APPLIED AND PRIOR TO RUN COMMAND. "ON" "OFF"
STATUS
STATUS
STATUS
ISO1
ISO2
ISO3
ISO4
ISO5
ISO6
ISO1
ISO2
ISO3
ISO4
ISO5
ISO6
PWR
OK
PWR
OK
PWR
OK
L2 L3 T1 T2 T3
I
TO RTD MONITOR [O,16]
N FS1 FS2 F1C F1D F2C F2D F3C F3D FS3 F1B F1E F2B F2E F3B F3E F1A F2A F3A F1F F2F F3F
I
ALL RELAYS SHOWN IN DE-ENERGIZED STATE.
BLU/WHT RD TO MXPB3 [R,15] BK R 1 2 W 3 B 4 5 6 #18AWG 1 C1 11 2 3 C2 12 4 5 C3 13 6 117 1 2 GND FLT J15 2000:1 GFCT INPUT 118 F1A F1B F1C F1D F1E F1F FS1 F2A F2B F2C F2D F2E F2F FS2 F3A F3B F3C F3D F3E F3F FS3 PIN5(BLU/WHT) LEDS IN CONNECTOR INLINE (IL) CONTACTOR COIL [D,16] G 25 R3 PROGRAMMABLE RELAY LED1 G CPU LED3 R 5V PWR TB5 ANALOG INPUT +10V MAX RX TX AIN POWER AIN+ AINCOM R J1 RJ45 RTD MODULE CABLE PIN4(BLU) PIN8(BRN) BLU/WHT 1 2 3 4 5 6 TO 24VDC POWER SUPPLY [I,4] BLU PHASE 3 FIBER OPTIC GATE DRIVER PHASE 2 FIBER OPTIC GATE DRIVER PHASE 1 FIBER OPTIC GATE DRIVER
BK
X1 X1
PC CARD RELAY CONTACT RATINGS: R1/R2: N/O CONTACT (RESISTIVE) = 5A@125VAC/250VAC/30VDC 1250VA N/C CONTACT (RESISTIVE) = 3A@125VAC/250VAC/30VDC 750VA R3 = 10A@125VAC/250VAC/30VDC 2500VA R4/R5/R6: RESISTIVE = 5A@125VAC/250VAC/30VDC 1250VA
SCR 1A SCR 1B
X2 X2 X2 25 30 31 66 BYPASS CONFIRM 67 68 BYPASS CONTACTOR COIL 69 52 53 54 PULSE GENERATOR CARDS (24VAC) INLINE CONTACTOR COIL INLINE CONFIRM DISCONNECT INTERLOCK CONTROL POWER NEUTRAL (120VAC)
X2
N N J8 LINE VOLTAGE SENSING DIVIDER CARD TB1 120 VAC INPUT POWER J10 5A CT INPUT
CUSTOMER MUST ONLY USE OF THE THREE START/STOP CONTROL METHODS SHOWN ON DRAWING * REMOTE COMMUNICATION CONTACT (OPTIONAL) * TWO WIRE CONTROL START CONTACT * THREE WIRE CONTROL START/STOP PUSH BUTTONS
X1
L L LIVE LIVE 1(L) 2(N) #18AWG 1 2 J4
DO NOT CONNECT POWER FACTOR OR SURGE CAPACITORS TO THE LOAD SIDE OF STARTER. IF USING SHIELDED CABLE, BENSHAW MUST BE CONSULTED.
L
CONSULT FACTORY IF TRANSFORMER MVA IS OVER 20 AND/OR CABLE LENGTH FROM STARTER TO MOTOR IS OVER 600 FEET.
J1
SCR 2B SCR 2C SCR 2D SCR 2E LED1 LED8 G CPU SCR 3A SCR 2F PHASE 2 STACK OT
BIPC-450100-01 CARD SET TERMINAL TORQUE: 5.0 IN. LBS. WEIDMULLER CONTROL TERMINALS TORQUE: 12.4 IN. LBS.
M
R1 PROGRAMMABLE RELAY
R POWER
BIPC-300055-02 MX CARD
N
R2 PROGRAMMABLE RELAY TB2 RELAY OUTPUTS SEE I/O CHART FOR SETTINGS
N
SPARE
X X
25
X2
SPR-100P
RTD MONITOR
COM DC
[X,Y] [A-X,Y]
R4 PROGRAMMABLE RELAY
P
1 B A 05/08/12 02/27/12 02/16/12 JDH JDH JDH DESIGN REV MODEL: DATE DESCRIPTION DRN CHECKED
AOUT TB5 ANALOG OUTPUT J3 RELAY OUTPUTS SEE I/O CHART FOR SETTINGS LED2 LED3 R RS485 TX COM SHIELD
INLINE CONTACTOR CONTACT N.O. BYPASS CONTACTOR CONTACT N.O. INLINE CONTACTOR CONTACT N.C.
WHT BK
78 79
R5 PROGRAMMABLE RELAY
1 2
BK
80
ETHERNET
RED WHT BK
RED
81
R6 PROGRAMMABLE RELAY
G RS485 RX
WHT
POWER
COM
3
BK RD
TWO WIRE CONTROL 1 STAT FBK THREE WIRE CONTROL START STOP 2 J7 J2 U24 MOT PTC 1 2 MOUNTED IN LOW VOLTAGE DOOR SW1 1 2
CUSTOMER:
X1
24
24
1 START
SW2 RESET
SW3 PARAM
SW4 DOWN
SW5 UP
SW6 ENTER
86 87 X X X X X X X
23
23
KPMX3LLCD
2 DI1 TB3 OPTO INPUTS SEE I/O CHART FOR SETTINGS RJ45 J2 RJ45 KEYPAD/DISPLAY CARD
R
3 DI2
LCD DISPLAY
A G
4 DI3
STOP RESET 1
START
MENU
I/O 02 I/O 03
5 COM 1 2 3 DI4 DI5 DI6 J6 PROGRAMMABLE DIGITAL INPUTS SEE I/O CHART FOR SETTINGS
ENTER
I/O 04 I/O 05
T
SPARE
2 RD/BLK
I/O 06
66 67 68 69
BYPASS (BP) CONTACTOR COIL [F,18]
X X X X X X X SHEET
BENSHAW CANADA CONTROLS INC. 550 BRIGHT STREET EAST, LISTOWEL, ONTARIO, CANADA N4W 3W3 PH. (519)291-5112 FAX (519)291-2595 WWW.BENSHAW.COM BENSHAW 615 ALPHA DR PITTSBURGH, PENNSYLVANIA, U.S.A. 15238 PH. (412)968-0100 FAX (412)968-5414 WWW.BENSHAW.COM
3 J5 (BYPASS CONFIRM) 4
RD/GRY
BENSHAW
U
X1
DISCONNECT AUXILIARY CONTACT (SHOWN WITH DISCONNECT OPEN) (D,3)
30
30
DI7
31
5 (BYPASS COIL) 6
RD/Y
31
5 6
DI8 COM
WHT #16AWG
I/O 21
1 OF 1 NTS
SHT.
REV.
DRAWING/SERIAL No.
MADE IN CANADA
15 16 17 18 19 20 21
SCALE
D 1