Sie sind auf Seite 1von 40

Street Lighting Simulation with SITECO SL10 in RELUX

August 2011

Introduction and Installation of Relux Import IES Files of SITECO SL10 - 3 ways Quick Street Planning Design with Relux Step by Step - Design with SITECO SL10 in Relux Siteco Website - Service and References

QAZ 18.08.2011

Relux Informatik AG, Switzerland, is an established company for the development, production and marketing of light planning- and visualisation software. The company operates globally and market leader in different countries. It is manufacturer-neutral and independent. A team of 15 keeps the products abreast of the latest technological developments. Free support by phone or e-mail ensures efficient service and customer satisfaction. Relux customers also have distribution partners at their disposal in other countries. Product overview: - ReluxPro the free lighting planning tool for all those interested in lighting, worldwide. - ReluxEnergy for free proof of the energy consumption of lighting in a building. - ReluxCAD, the PlugIn for realistic lighting planning in AutoCAD. - ReluxTunnel the leading planning program for tunnel lighting. - Seminars and workshops in a large number of countries, to uniform quality standards. - Data management and software development. - Consulting, planning and other services

QAZ 18.08.2011

MAIN MENU

TOOLBARS

PROJECT MANAGER

ACTION WINDOW

QAZ 18.08.2011

Goto http://www.relux.biz
5 QAZ 18.08.2011

Introduction and Installation of Relux Import IES Files of SITECO SL10 - 3 ways Quick Street Planning Design with Relux Step by Step - Design with SITECO SL10 in Relux Siteco Website - Service and References

QAZ 18.08.2011

To add siteco luminaires data into ReluxSuite

Double click on the siteco-relux application file

Click RUN

Click OK

QAZ 18.08.2011

Click ACCEPT Click NEXT

After finished adding the data, siteco luminaires data are ready to use in Relux

QAZ 18.08.2011

Start Relux and Go to INSERT->Luminaires->New single luminaire

QAZ 18.08.2011

Local

10

QAZ 18.08.2011

Online

11

QAZ 18.08.2011

Individual luminaire

12

QAZ 18.08.2011

Introduction and Installation of Relux Import IES Files of SITECO SL10 - 3 ways Quick Street Planning Design with Relux Step by Step - Design with SITECO SL10 in Relux Siteco Website - Service and References

13

QAZ 18.08.2011

Start Relux and choose Road project

14

QAZ 18.08.2011

Select local and choose the luminaire needed

15

QAZ 18.08.2011

Click Add

16

QAZ 18.08.2011

Go to Selected to view the luminaire selected details and click Ok

luminaire details

17

QAZ 18.08.2011

Under Project definition enter all the data required

18

QAZ 18.08.2011

Select Defaults for calculations / Outputs and choose the lighting classes required and click Start

19

QAZ 18.08.2011

Shows an overview of the current project incl. calculation results

20

QAZ 18.08.2011

Result overview

Data input by user

Requirement for ME5

Result achieved

21

QAZ 18.08.2011

To view in 3Dview, right click on Room structure and choose Change street to exterior scene

22

QAZ 18.08.2011

click Yes and Ok

23

QAZ 18.08.2011

click 3D View

24

QAZ 18.08.2011

click Luminaires are represented in the floor plan with alignment arrows to show the aiming

25

QAZ 18.08.2011

click Show 3D light distribution to show lighting curve

26

QAZ 18.08.2011

click Starts an artificial light calculation to calculate

27

QAZ 18.08.2011

Calculation results display and click on Luminance distribution in 3D to view 3D view after calculation

28

QAZ 18.08.2011

Click on Output to view 3D pseudo colours

29

QAZ 18.08.2011

Introduction and Installation of Relux Import IES Files of SITECO SL10 - 3 ways Quick Street Planning Design with Relux Step by Step - Design with SITECO SL10 in Relux Siteco Website - Service and References

30

QAZ 18.08.2011

Step 1 : Example road information needed Lighting Class : ME1, ME2, ME3a, etc Road layout : with median, without median, etc Road arrangement : Single row, Opposite, Staggered, etc Road surface category : R1, R2, R3 Road width Number of lane Lane width Lamp wattage Tilt angle Pole spacing Pole height Arm length Setback For this example we will use these information : Lighting Class : ME3a Road arrangement : Single row Road surface category : R3 Road width : 7m Number of lane : 2 Lane width : 3.5m Pole spacing : 33m Pole height : 10m

31

QAZ 18.08.2011

Step 2 : Result overview

Table

1 2 3

Isoline

Pseudo colours

32

QAZ 18.08.2011

Step 3 : Printout as PDF file File -> Print Manager

33

QAZ 18.08.2011

Introduction and Installation of Relux Import IES Files of SITECO SL10 - 3 ways Quick Street Planning Design with Relux Step by Step - Design with SITECO SL10 in Relux Siteco Website - Service and References

34

QAZ 18.08.2011

Goto siteco website: http://www.siteco.com/en/home.html

35

QAZ 18.08.2011

Goto service

36

QAZ 18.08.2011

Goto Planning tools/ lighting calculation

Siteco Relux plugin Relux suite download

37

QAZ 18.08.2011

Goto Planning tools/ sample projections

Siteco - sample relux calculation at six main sectors

38

QAZ 18.08.2011

Siteco Malaysia website: http://www.siteco.com.my/my/home.html

project references in Malaysia


39 QAZ 18.08.2011

THE END