MW installation
Installation material
MW installation
IF connector
MW installation
IF cable connector
MW installation
Power connector
GND
MW installation
Installation material
MW installation
Installation material
MW installation
Installation material
MW installation
Installation material
MW installation
Installation material
MW installation
Antenna installation
The antenna and ODU polarization should be consistent with the engineering design document
MW installation
Antenna installation
The fixation of antenna and pole are reliable. For the more than 1.2m antenna, the side strut must be installed and fixed position is correct.
MW installation
Antenna installation
MW installation
Antenna polarization
MW installation
ODU polarization
MW installation
ODU Check
MW installation
Hybrid installation
MW installation
Hybrid installation
MW installation
Hybrid installation
MW installation
MW installation
Hybrid polarization
MW installation
ODU installation
The IF connector of ODU should be waterproofed and face downward.
The ODU grounding cable should be shortest length as possible and attached to grounding system by the cable clamp.
MW installation
ODU installation
MW installation
IF cable routing
IF redundant: Leave enough slack when connecting cables to the ODU to facilitate future maintenance, and IF cable should be fixed tightly
MW installation
IF cable routing
The IF cable route and position for the cabling should be designed beforehand and arranged neatly. IF cable turns should be smooth, and the bending radius should be larger than 30 cm.
MW installation
IF cable routing
MW installation
Rack installation
MW installation
Rack installation
MW installation
IDU installation
IF cable Every cable should be labeled
Grounding cable
E1 cable
MUX Installation
MW installation
IDU installation
MW installation
MW installation
MUX Installation
Firber Routing
Redundant length of fiber connection lines at both ends should be identical and compliant with the technical requirements.
Firber Routing
The bending radius of the fiber connection lines inside the troughs at the turning points should be not less than 38 ~ 40 mm.
Fiber connection lines should be protected with tubes or troughs. The parts without tubes should be bound with proper force with cable ties.
The bundled fiber connection lines should be straight without evident twists in troughs.
should paste a good label, and the label should be written normally.
E1 Cable
The route and direction of E1 cables should comply with the design.
E1 Cable
The cables in the aisle must be