EPRO INJECTION TUBE SYSTEM

Permanent Cold Joint Waterproofing

Redundant Waterstop Protection


• Injection only required if leakage occurs
• Applicable in both dry and wet conditions
• Tenacious bonding polyurethane sealant
• Does not damage the concrete
• Extremely durable and effective

Uncured Product Comp. A Comp. B 1400 CAT ASTM

Appearance ........................................ Clear ............................. Dk. Brown .................... Clear


Solids .................................................. 100% ............................ 100% ........................... 100% ............................ D 1010
Density, g/ml ...................................... 1.02 .............................. 1.14 .............................. 1.16 .............................. D 3800-79
Flash Point, C/F ................................. 156/313 ........................ 180/356 ........................ 165/335 ......................... D 93-85
Viscosity, cps ...................................... 60-70 ............................ 80-90 ........................... 50 .................................. D 1638-74
Mixing Ratio ....................................... 1 part ............................ 1 part ........................... 5% max.
Packaging .......................................... 5-gal. ............................ 5-gal. ........................... 5-gal.

Cured Product

Hardness, Shore D .......................................... 20-30


Elongation, % ................................................... >100 ................................................................................ ASTM D 638
Tensile Strength, psi ........................................ 260 .................................................................................. ASTM D 638
Adhesive Strength to Concrete, psi ................. >260
Corrosiveness .................................................. Non-Corrosive
Storage ............................................................ Good storage stability at 15-30° C, 58-85° F. Store indoors.
Appearance ...................................................... Dark Brown Polyurethane Sealant
Toxicity ............................................................. Essentially Non-Toxic in cured form. MDI Based, Drinking Water Approved.
Resistance to Chemicals .................................. Resistant to Most Organic Solvents, Mild Acids, Alkali and Micro Organisms

OF DIFFE
OR
LD RE
Phone: 800-882-1896
EPRO SERVICES W
N
CE
A

316-262-2513
P.O. Box 347 Fax: 316-262-2529
S
FO

ON

Derby, KS 67037 USA


R

web site: www.eproserv.com


TI

Wa te r p r oo f i n g Sys tems EA I
R

LW ND
ORLD CO

rev.: it 07.15.05
INJECTION TUBE Specifications
1. PRODUCT NAME 4. TECHNICAL DATA 6. AVAILABILITY AND COST

INJECTION TUBE SYSTEM Properties: Not Available Contact the local distributor and/or Author-
Coverages: Not Available ized Applicator for availability and cost.
2. MANUFACTURER
Specification Writer: 7. WARRANTY
EPRO SERVICES, INC. Contact EPRO Services before writing specifi-
P.O. Box 347 cations on this product. Limited Warranty: EPRO warrants this prod-
Derby, KS 67037 uct to be free from defects. EPRO makes no
PHONE: 800-882-1896 5. INSTALLATION other warranties with respect to this product,
FAX: 316-262-2529 express or implied, including without limita-
Preparation: tion the implied warranties of MERCHANT-
3. PRODUCT DESCRIPTION • Remove any loose debris. ABILITY OR FITNESS FOR PARTICULAR
• Repair any concrete area prior to placement PURPOSE. EPRO’s liability shall be limited
Basic Use: of the injection tube application. in all events to supplying sufficient product to
The Epro injection tube system is designed to • Place tube in direct contact with concrete us- retreat the specific areas to which defective
be installed at the time of construction with the ing clips or rebar and wire to hold in place ev- product has been applied. EPRO shall have
intent of providing the ability to inject polyur- ery 12”. no other liability, including liability for inci-
ethane resin such as Epro PU403 after con- • The clips maybe attached using nails or ep- dental or resultant damages, whether due to
struction is completed to repair leakage at cold oxy adhesive. breach of warranty or negligence. This war-
joints if it should occur or as a permanent pre- • Tension on the tube should be sufficient to ranty may not be modified or extended by
ventive water stop measure. prevent movement during concrete placement. representatives of EPRO or its distributors.
• 30’ tube sections should overlap each other
Composition: 12”. 8. MAINTENANCE
• A sturdy PVC hose withstands pressures up • Each PVC injection sleeve is attached to the
to 60 ft. of poured concrete. end of each tube segment and is bent at 90° an- No maintenance required.
• A layer of tightly woven fabric (filter) pre- gle before exiting the surface of the concrete.
vents concrete particles from entering the tube. • The PVC injection sleeve shall extend 1”-3” 9. TECHNICAL SERVICES AND INFORMA-
• Perforations in the hose which allows the res- beyond the surface of the concrete. TION
in to flow out the tube without loss of pressure.
• A top layer of tough plastic fabric protects Application: Complete technical services and information
the filter fabric against damage. • Mix part A with part B at a ratio of 1 to 1. are available from EPRO Services.
• The sleeves and screws provide for easy in- • Inject the resin mixture with approved high
stallation and resin injection. pressure injection equipment.
• Insert screws after completing resin injection.
Benefits:
• Complete waterproofing of cold joints. Cleaning: Not Applicable
• Easy installation with no damage to concrete.
• Selective injection based on water leakage is
an option.
• Comprised of durable material with no metal OR
LD
OF DIFFE
RE
N
W
components.
CE
A

• Cost effective.
S
FO

ON
R

TI

Wa te r p r oo f i n g Sys tems EA I
R

LW ND
Limitations: ORLD CO

• Must be installed in strict compliance with


published guidelines.
• Maximum tube length section 30 ft.
• Injection sleeves must remain visible after
placement of concrete.