24:1994
Analytical laboratories
Department of Defence, Materials Research Laboratory
Steel manufacturers
STANDARDS AUSTRALIA
1 The Crescent,
Homebush NSW 2140 Australia
PREFACE
This Standard was prepared by the Joint Standards Australia/Standards New Zealand
Committee CH/10 on the Analysis of Metals to supersede AS K1.24—1968, Method for
the sampling and analysis of iron and steel, Part 24: Method for the determination of
aluminium in iron and steel (photometric method) .
It is issued as a Joint Standard under the terms of the Active Cooperation Agreement
between Standards Australia and Standards New Zealand.
CONTENTS
This is a free 5 page sample. Access the full version at http://infostore.saiglobal.com.
Page
1 SCOPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2 REFERENCED DOCUMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3 PRINCIPLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
4 REAGENT REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
5 APPARATUS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
6 SAMPLING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
7 PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
8 CALIBRATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
9 PRECISION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
10 ACCEPTANCE OF ANALYTICAL VALUES . . . . . . . . . . . . . . . . . . . . . . . . . 8
11 TEST REPORT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1 SCOPE This Standard sets out a spectrophotometric method for the determination of
aluminium in steel. It is applicable to all steels with aluminium content in the range
0.002% to 1.4% aluminium.
This is a free 5 page sample. Access the full version at http://infostore.saiglobal.com.
3 PRINCIPLE The test portion is dissolved in acid and any insoluble aluminium
recovered by fusion with sodium hydrogen sulfate. Interfering elements are separated by a
mercury cathode separation and a cupferron solvent extraction. The aluminium content is
calculated from the measured absorbance of the coloured complex formed with
calcium-alizarin Red S.
4 REAGENT REQUIREMENTS
4.1 General All reagents shall be of analytical reagent grade and distilled water or
water of equivalent purity shall be used throughout. All solutions should be stored in
polyethylene or polypropylene containers.
4.2 Solutions
4.2.1 Nitric acid Carefully add 250 mL of nitric acid (ρ20 1.42 g/mL) to 250 mL of
water.
4.2.2 Hydrochloric acid (ρ20 1.18 g/mL)
4.2.3 Perchloric acid (ρ 20 1.67 g/mL)
WARNING: PERCHLORIC ACID REACTS EXPLOSIVELY WITH ORGANIC
MATTER AND IS CORROSIVE TO SKIN, ESPECIALLY MUCOUS MEMBRANES
COPYRIGHT