Sie sind auf Seite 1von 8

CONCRETE PRESSURE PIPE

PRESTRESSED CONCRETE LINED CYLINDER PIPE AWWA C301 [L] Product Description

Prestressed Concrete Cylinder Pipe is manufactured according to AWWA C301 and designed according to AWWA C304 standards. Prestressed Concrete Cylinder Pipe is used in a wide variety of applications which include transmission mains, distribution feeder mains, power plant cooling-water lines, sewage force mains, gravity sewers, subaqueous lines, water intake and discharge lines and industrial pressure lines. Lined Cylinder Pipe AWWA C301 (L) The pipe consists of a welded steel cylinder, steel joint rings, a centrifugally placed concrete lining, high tensile steel wire and a dense cement mortar coating over the prestressing wire and core. An O-ring rubber gasket is incorporated at each joint for water tightness and flexibility. Contact our Sales Department ( 1.800.461.5632 ) for your project pricing.

LINED CYLINDER PIPE SECTION AWWA C301 [L]

PRESTRESSED CONCRETE LINED CYLINDER PIPE AWWA C301 [L] Dimensions

LINED CYLINDER PIPE AWWA C301 [L]


Standard Dimensions

CORE STANDARD JOINT THICKNESS JOINT DIAMETER DIAMETER DIAMETER (mm) DEPTH (mm)

NOMINAL PIPE

PIPE INSIDE

APPROX. WEIGHT

BELL OUTSIDE

BARREL OUTSIDE

STANDARD LAYING

(kg/m) 230 270 300 380 560 710 970 1230 1460 1640

(mm) 400 450 500 600 750 900 1050 1200 1350 1500

(mm) 406 457 508 610 762 914 1067 1219 1372 1524 25 29 32 38 48 57 67 76 86 95

(mm) 114 114 114 114 114 114 114 114 121 124 470 527 584 699 870 1041 1200 1372 1565 1738

DIAMETER DIAMETER (mm) (mm) 572 629 686 800 972 1143 1302 1473 1667 1838 508 565 622 737 908 1080 1251 1422 1594 1765

LENGTH (m) 6.106 6.106 6.106 6.106 6.106 6.106 6.106 6.106 6.106 6.106

PRESTRESSED CONCRETE EMBEDDED CYLINDER PIPE AWWA C301 [E] Product Description

Prestressed Concrete Cylinder Pipe is manufactured according to AWWA C301 and designed according to AWWA C304 standards. Prestressed Concrete Cylinder Pipe is used in a wide variety of applications which include transmission mains, distribution feeder mains, power plant cooling-water lines, sewage force mains, gravity sewers, subaqueous lines, water intake and discharge lines and industrial pressure lines. Embedded Cylinder Pipe AWWA C-301 (E) The pipe consists of a welded steel cylinder, steel joint rings, a vertically cast concrete core, high tensile steel wire and a dense cement mortar coating over the wire and the core. An O-ring rubber gasket is incorporated at each joint for water tightness and flexibibility. Contact our Sales Department ( 1.800.461.5632 ) for your project pricing.

EMBEDDED CYLINDER PIPE SECTION AWWA C301 [E]

PRESTRESSED CONCRETE EMBEDDED CYLINDER PIPE AWWA C301 [E] Dimensions

EMBEDDED CYLINDER PIPE AWWA C301 [E]


Standard Dimensions

NOMINAL PIPE DIAMETER (mm) 1050 1200 1350 1500 1650 1800 1950 2100 2250 2400 2550 2700 2850 3000 3150 3300 3450 3600

PIPE CORE STANDARD INSIDE THICKNESS JOINT DIAMETER (mm) DEPTH (mm) (mm) 1067 1219 1372 1524 1676 1829 1981 2134 2286 2438 2591 2743 2896 3048 3200 3353 3505 3658 89 102 102 114 127 140 152 165 165 165 165 171 181 190 200 210 219 229 114 114 130 133 137 114 143 114 149 149 152 152 152 152 152 152 152 152

JOINT DIAMETER (mm) 1143 1302 1467 1622 1781 1943 2095 2255 2410 2569 2715 2873 3064 3216 3369 3521 3673 3826

APPROX. WEIGHT (kg/m) 1120 1340 1490 1680 2240 2650 3070 3560 3780 4020 4320 4690 5140 6030 6260 6780 7370 7970

BARREL OUTSIDE DIAMETER (mm) 1295 1473 1626 1803 1981 2159 2337 2518 2670 2822 2975 3140 3311 3483 3686 3826 3997 4169

STANDARD LAYING LENGTH (m) 6.106 6.106 6.106 6.106 6.106 6.106 6.106 6.106 6.106 6.106 6.106 6.106 6.106 4.887 4.887 4.887 4.887 4.887

NON-CYLINDER REINFORCED CONCRETE PRESSURE PIPE AWWA C302 Product Description

Non-Cylinder Reinforced Concrete Pressure Pipe AWWA C302 Non-Cylinder Reinforced Concrete Pressure Pipe AWWA C302 is manufactured according to AWWA C302 standard and designed according to AWWA M9 Manual. Non-Cylinder Reinforced Concrete Pressure Pipe is used in applications where the working pressure is limited to 380 kPa (55psi). Typical applications include low pressure sewage force mains, gravity sewers, water intakes, outfalls and low pressure water supply systems. The pipe does not require a steel cylinder, but contains reinforcing cages and incorporates welded steel bell and spigot joint rings encased in the concrete wall of the pipe. Contact our Sales Department ( 1.800.461.5632 ) for your project pricing.

NON-CYLINDER REINFORCED CONCRETE PIPE SECTION AWWA C302

NON-CYLINDER REINFORCED CONCRETE PRESSURE PIPE AWWA C302 Dimensions


NON-CYLINDER REINFORCED CONCRETE PIPE AWWA C302
Standard Dimensions
NOMINAL PIPE DIAMETER (mm) 900 1050 1200 1350 1500 1650 1800 1950 2100 2250 2400 PIPE WALL STANDARD INSIDE THICKNESS JOINT DIAMETER (mm) DEPTH (mm) (mm) 914 1067 1219 1372 1524 1676 1829 1981 2134 2286 2438 76 89 102 114 127 140 152 165 178 191 203 114 114 114 130 133 137 114 143 114 149 149 JOINT DIAMETER (mm) 991 1143 1302 1467 1622 1781 1943 2095 2255 2410 2569 APPROX. WEIGHT (kg/m) 940 1080 1341 1861 2308 2790 2590 3680 4220 4540 4800 BARREL OUTSIDE DIAMETER (mm) 1066 1245 1422 1600 1778 1956 2133 2311 2490 2668 2844 STANDARD LAYING LENGTH (m) 6.106 6.106 6.106 6.106 6.106 6.106 6.106 6.106 6.106 6.106 6.106

Information on 2550 mm to 3600 mm nominal pipe diameter is available upon request.

CONCRETE PRESSURE PIPE TAPPING SYSTEMS

LINED CYLINDER PIPE Tapping prestressed concrete pressure pipe is a common occurrence in todays public works projects. Munro Concrete Products Ltd. field service representatives are fully equipped to provide the technical expertise, material and installation services to make service taps up to 1200mm in diameter (and larger under cer tain circumstances) on any type of pressure pipe. In most cases, this work can be done under pressure without interrupting service to customers. For maximum tapping diameter of pipe, please see tables. NOMINAL PIPE DIAMETER (mm) 400 450 500 600 750 900 1050 1200 1350 1500 MAXIMUM TAP DIAMETER (mm) 300 350 400 450 500 600 750 900 1050 1200

EMBEDDED CYLINDER PIPE NOMINAL PIPE DIAMETER (mm) 1050 1200 1350-3600 MAXIMUM TAP DIAMETER (mm) 750 900 *

*Two sizes smaller than nominal pipe diameter

Address:

8807 Simcoe Road #56, Utopia, ON L0M 1T0


Telephone:

7 0 5. 7 3 4 . 2892 1 . 8 0 0.4 61 . 5 63 2
Engineering Fax:

7 0 5. 7 3 4 . 2 27 0
Administration Fax:

7 0 5. 7 3 4 . 2920
sales@munroconcrete.com

www.munroconcrete.com All inquiries, call toll free:

800.461.5632