Sizing - Caudal

Project : SENA
Customer: C.Project No.: 0
Contact person: --- Phone: --- Fax: ---
eMail: ---
TAG :
Timestamp: 03.03.2008 03:01:00 PM COT Review number: 1
Hoja de clculo dimensiones
Parmetros generales
Fluido : Agua, process Ref. Temperatura : n.a.
Estado : Liquido Ref. Presin n.a.
Carcter : Limpio Presin atmosfrica : 14.7 psi abs
Abrasin : No abrasivo Estndar : ANSl
Grupo fluido : Fluido normal
Condiciones de operacin
Mnimo Operation Mximo
Caudal solicitado : 0 20 40 l/min
Presin : 60 psi abs
Temperatura : 25 C
Densidad : 62.27 lbs/ft3
Viscosidad : 0.9039 cSt
Presin vapor : 0.2892 0.3974 6.672 psi abs
Presin (min/max) : 60 60 psi abs
Temp. (min/max) : 20 80 C
Caudalmetro : 40E - Promass (CMF)
Dimetro nominal : 1/2"
Caudal mnimo : 0 l/min
Caudal mximo : 108.611 l/min
Dimetro interno (Sensor) : 0.327 inch
Presin mnima : Cl 150 ANSl / 316L/1.4404 Brida B16.5
Material (sensor) * : SS 1.4539 / 904L
PED ** : Segn las condiciones de proceso y fluido especificados, el equipo est en el mbito del articulo 3.3 de la PED. Por
este motivo, Applicator no propone ningn equipo con opcin PED.
Cdigo pedido : | 4 | 0 | E | 1 | 5 | - | A | A | A | S | | | | | | | | |
Dimensionado y resutados de clculo
Mnimo Operation Mximo
Caudal solicitado : 0 20 40 l/min
Prdida de carga : 0 1.171 4.223 psi
Velocidad (tubos de medida) : 0 10.11 20.21 ft/s
lncertidumbre en volmen*** : +lnfinity 0.75 0.73 %
lncertidumbre en masa*** : +lnfinity 0.55 0.53 %
Nmero de Reynolds : 28 286
Advertencias / Mensajes de error
*El usuario es responsable por la seleccin de los materiales de contacto en funcin de la resistencia a la corrosin. Endress+Hauser Flowtec AG no
garantiza ni asume responsabilidad alguna sobre la resistencia de materiales a la corrosin seleccionados aqu por la aplicacin descrita.
** La categora PED es una recomendacin E+H y depende de la categora del fluido, datos de proceso y de la max. presin permisible del factor de
presin seleccionado.Los fluidos de la base de datos del Applicator estn clasificados segn 67/548/EWG.
***El clculo de error se basa en los datos de especificacin de la lnformacin Tcnica (Tl) del caudalmetro seleccionado.
Print date : 17.03.2008 11:49:27 AM COT
Applicator: 10.01.00 / 68
- 1 / 14 -
Under no circumstances is Endress+Hauser Flowtec AG liable for errors, neither in the Software and in its documentation, nor for
any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the
user. A change in these parameters could lead to different results.
Sizing - Caudal
Project : SENA
Customer: C.Project No.: 0
Contact person: --- Phone: --- Fax: ---
eMail: ---
TAG :
Timestamp: 03.03.2008 03:01:00 PM COT Review number: 1
Dimensiones tres dimetros (Trisize)
Parmetros generales
Fluido : Agua, process Ref. Temperatura : n.a.
Estado : Liquido Ref. Presin n.a.
Carcter : Limpio Presin atmosfrica : 14.7 psi abs
Abrasin : No abrasivo Estndar : ANSl
Grupo fluido : Fluido normal
Condiciones de operacin
Mnimo Operation Mximo
Caudal solicitado : 0 20 40 l/min
Presin : 60 psi abs
Temperatura : 25 C
Densidad : 62.27 lbs/ft3
Viscosidad : 0.9039 cSt
Presin vapor : 0.2892 0.3974 6.672 psi abs
Presin (min/max) : 60 60 psi abs
Temp. (min/max) : 20 80 C
Dimensionado y resutados de clculo
Dimetro inferior Dimetro nominal estndar Dimetro superior
Dimetro interno (Sensor) : 0.211 0.327 0.472 inch
Dimetro nominal : 3/8" 1/2" 1"
Presin mnima : Cl 150 ANSl / 316L/1.4404 Cl 150 ANSl / 316L/1.4404 Cl 150 ANSl / 316L/1.4404
Caudal mnimo : 0 0 0 l/min
Caudal mximo : 33.419 108.611 300.769 l/min
Prdida de carga a caudal mn. : 0 0 0 psi
Prdida de carga a caudal nom. : 8.762 1.171 0.291 psi
Prdida de carga a caudal mx. : 31.59 4.223 1.047 psi
Velocidad (tubos de medida) a caudal mn. : 0 0 0 ft/s
Velocidad (tubos de medida) a caudal nom. : 24.33 10.11 4.835 ft/s
Velocidad (tubos de medida) a caudal mx. : 48.65 20.21 9.67 ft/s
lncertidumbre en volmen a caudal mn.
solicitado*** :
+lnfinity +lnfinity +lnfinity %
lncertidumbre en volmen a caudal nom.
Solicitado*** :
0.72 0.75 0.85 %
lncertidumbre en volmen a caudal mx.
solicitado*** :
n.a. 0.73 0.78 %
lncertidumbre en masa a caudal mn.
solicitado*** :
+lnfinity +lnfinity +lnfinity %
lncertidumbre en masa a caudal nom.
Solicitado*** :
0.52 0.55 0.65 %
lncertidumbre en masa a caudal mx.
solicitado*** :
n.a. 0.53 0.58 %
Nmero de Reynolds : 43 882.9 28 286 19 564.5
*El usuario es responsable por la seleccin de los materiales de contacto en funcin de la resistencia a la corrosin. Endress+Hauser Flowtec AG no
garantiza ni asume responsabilidad alguna sobre la resistencia de materiales a la corrosin seleccionados aqu por la aplicacin descrita.
***El clculo de error se basa en los datos de especificacin de la lnformacin Tcnica (Tl) del caudalmetro seleccionado.
Print date : 17.03.2008 11:49:27 AM COT
Applicator: 10.01.00 / 68
- 2 / 14 -
Under no circumstances is Endress+Hauser Flowtec AG liable for errors, neither in the Software and in its documentation, nor for
any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the
user. A change in these parameters could lead to different results.
Sizing - Caudal
Project : SENA
Customer: C.Project No.: 0
Contact person: --- Phone: --- Fax: ---
eMail: ---
TAG :
Timestamp: 03.03.2008 03:01:00 PM COT Review number: 1
Hoja grficos
Parmetros generales
Fluido : Agua, process Abrasin : No abrasivo
Estado : Liquido Presin atmosfrica : 14.7 psi abs
Carcter : Limpio Estndar : ANSl
Condiciones de operacin
Mnimo Operation Mximo
Caudal solicitado : 0 20 40 l/min
Presin : 60 psi abs
Temperatura : 25 C
Densidad : 62.27 lbs/ft3
Viscosidad : 0.9039 cSt
Presin vapor : 0.2892 0.3974 6.672 psi abs
Presin (min/max) : 60 60 psi abs
Temp. (min/max) : 20 80 C
Caudalmetro : 40E - Promass (CMF)
Dimetro nominal : 1/2"
Caudal mnimo : 0 l/min
Caudal mximo : 108.611 l/min
Dimetro interno (Sensor) : 0.327 inch
Cdigo pedido : | 4 | 0 | E | 1 | 5 | - | A | A | A | S | | | | | | | | |
***El clculo de error se basa en los datos de especificacin de la lnformacin Tcnica (Tl) del caudalmetro seleccionado.
Print date : 17.03.2008 11:49:27 AM COT
Applicator: 10.01.00 / 68
- 3 / 14 -
Under no circumstances is Endress+Hauser Flowtec AG liable for errors, neither in the Software and in its documentation, nor for
any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the
user. A change in these parameters could lead to different results.
Sizing - Caudal
Project : SENA
Customer: C.Project No.: 0
Contact person: --- Phone: --- Fax: ---
eMail: ---
TAG :
Timestamp: 03.03.2008 03:01:00 PM COT Review number: 1
lnformacin corrosin
Parmetros generales
Fluido : Agua, process Abrasin : No abrasivo
Estado : Liquido
Carcter : Limpio
lnterpretation of Data, Material(M):
A: resistante, 0.05 mm/y (0.002 pulgadas/y)
B: lnsuficientemente resistente, 0.5 mm/y (0.02 pulgadas/y)
C: No resistente, 1.3 mm/y (0.05 pulgadas/y)
NR: No recomendado
U: Desconocido
lnterpretacin datos, Plsticos(P):
A: resistante, 15% vol. dilatacin/y; 15% prdida de fuerza traccin/y
B: lnsuficientemente resistente, 30% vol. dilatacin/y; 30% prdida de fuerza traccin/y
C: No resistente, 50% vol. dilatacin/y; 60% prdida de fuerza traccin/y
NR: No recomendado
U: Desconocido
Temperatura
Material * Mnimo : 20C Operation : 25C Mximo : 80C
(P) EPDM : U U U
(M) Hastelloy C Alloy C-22/2.4602 : A A A
(P) Kalrez : A A A
(P) Silicona : A B B
(M) Acero inoxidable 304/1.4301 : A A A
(M) Acero inoxidable 316L/1.4404 : A A A
(M) Acero inoxidable 904L/1.4539 : A A A
(M) Titanio : A A A
(P) Viton : A A A
(M) Zirconio : A A A
*El usuario es responsable por la seleccin de los materiales de contacto en funcin de la resistencia a la corrosin. Endress+Hauser Flowtec AG no
garantiza ni asume responsabilidad alguna sobre la resistencia de materiales a la corrosin seleccionados aqu por la aplicacin descrita.
Print date : 17.03.2008 11:49:27 AM COT
Applicator: 10.01.00 / 68
- 4 / 14 -
Under no circumstances is Endress+Hauser Flowtec AG liable for errors, neither in the Software and in its documentation, nor for
any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the
user. A change in these parameters could lead to different results.
Sizing - Caudal
Project : SENA
Customer: C.Project No.: 0
Contact person: --- Phone: --- Fax: ---
eMail: ---
TAG :
Timestamp: 03.03.2008 03:05:23 PM COT Review number: 1
Hoja de clculo dimensiones
Parmetros generales
Fluido : Agua, process Ref. Temperatura : n.a.
Estado : Liquido Ref. Presin n.a.
Carcter : Limpio Presin atmosfrica : 14.7 psi abs
Abrasin : No abrasivo Estndar : ANSl
Grupo fluido : Fluido normal
Condiciones de operacin
Mnimo Operation Mximo
Caudal solicitado : 3 20 40 l/min
Presin : 60 psi abs
Temperatura : 25 C
Densidad : 62.27 lbs/ft3
Viscosidad : 0.9039 cSt
Presin vapor : 0.2892 0.3974 6.672 psi abs
Presin (min/max) : 60 60 psi abs
Temp. (min/max) : 20 80 C
Caudalmetro : 72F - Prowirl (VFM)
Dimetro nominal : 1/2"
Caudal mnimo : 2.368 l/min
Caudal mximo : 81.943 l/min
Dimetro interno (Sensor) : 0.547 inch
Presin mnima : Cl 150 ANSl / 316L/1.4404 Brida B16.5
Material (sensor) * : SS 1.4404 (CF3M) / 316L
PED ** : Caudalimetro excluido de la PED
Cdigo pedido : | 7 | 2 | F | 1 | 5 | - | S | K | | | | | | | | | | |
Dimensionado y resutados de clculo
Mnimo Operation Mximo
Caudal solicitado : 3 20 40 l/min
Prdida de carga : 0.015 0.646 2.583 psi
Velocidad (tubos de medida) : 1.081 7.207 14.41 ft/s
lncertidumbre en volmen*** : 20.5 0.75 0.75 %
lncertidumbre en masa*** : n.a. n.a. n.a. %
Nmero de Reynolds : 33 780.4
Frecuencia : 139.8 Hz
Advertencias / Mensajes de error
*El usuario es responsable por la seleccin de los materiales de contacto en funcin de la resistencia a la corrosin. Endress+Hauser Flowtec AG no
garantiza ni asume responsabilidad alguna sobre la resistencia de materiales a la corrosin seleccionados aqu por la aplicacin descrita.
** La categora PED es una recomendacin E+H y depende de la categora del fluido, datos de proceso y de la max. presin permisible del factor de
presin seleccionado.Los fluidos de la base de datos del Applicator estn clasificados segn 67/548/EWG.
***El clculo de error se basa en los datos de especificacin de la lnformacin Tcnica (Tl) del caudalmetro seleccionado.
Print date : 17.03.2008 11:49:27 AM COT
Applicator: 10.01.00 / 68
- 5 / 14 -
Under no circumstances is Endress+Hauser Flowtec AG liable for errors, neither in the Software and in its documentation, nor for
any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the
user. A change in these parameters could lead to different results.
Sizing - Caudal
Project : SENA
Customer: C.Project No.: 0
Contact person: --- Phone: --- Fax: ---
eMail: ---
TAG :
Timestamp: 03.03.2008 03:05:23 PM COT Review number: 1
Dimensiones tres dimetros (Trisize)
Parmetros generales
Fluido : Agua, process Ref. Temperatura : n.a.
Estado : Liquido Ref. Presin n.a.
Carcter : Limpio Presin atmosfrica : 14.7 psi abs
Abrasin : No abrasivo Estndar : ANSl
Grupo fluido : Fluido normal
Condiciones de operacin
Mnimo Operation Mximo
Caudal solicitado : 3 20 40 l/min
Presin : 60 psi abs
Temperatura : 25 C
Densidad : 62.27 lbs/ft3
Viscosidad : 0.9039 cSt
Presin vapor : 0.2892 0.3974 6.672 psi abs
Presin (min/max) : 60 60 psi abs
Temp. (min/max) : 20 80 C
Dimensionado y resutados de clculo
Dimetro inferior Dimetro nominal estndar Dimetro superior
Dimetro interno (Sensor) : 0.547 0.957 inch
Dimetro nominal : 1/2" 1"
Presin mnima : Cl 150 ANSl / 316L/1.4404 Cl 150 ANSl / 316L/1.4404
Caudal mnimo : 2.368 5.286 l/min
Caudal mximo : 81.943 250.436 l/min
Caudal lineal : 11.841 20.701 l/min
Prdida de carga a caudal mn. : 0.015 0.001 psi
Prdida de carga a caudal nom. : 0.646 0.06 psi
Prdida de carga a caudal mx. : 2.583 0.242 psi
Velocidad (tubos de medida) a caudal mn. : 1.081 0.354 ft/s
Velocidad (tubos de medida) a caudal nom. : 7.207 2.358 ft/s
Velocidad (tubos de medida) a caudal mx. : 14.41 4.716 ft/s
lncertidumbre en volmen a caudal mn.
solicitado*** :
20.5 n.a. %
lncertidumbre en volmen a caudal nom.
Solicitado*** :
0.75 9.39 %
lncertidumbre en volmen a caudal mx.
solicitado*** :
0.75 0.75 %
lncertidumbre en masa a caudal mn.
solicitado*** :
n.a. n.a. %
lncertidumbre en masa a caudal nom.
Solicitado*** :
n.a. n.a. %
lncertidumbre en masa a caudal mx.
solicitado*** :
n.a. n.a. %
Nmero de Reynolds : 33 780.4 19 322.9
Frecuencia : 139.8 26.2
*El usuario es responsable por la seleccin de los materiales de contacto en funcin de la resistencia a la corrosin. Endress+Hauser Flowtec AG no
Print date : 17.03.2008 11:49:27 AM COT
Applicator: 10.01.00 / 68
- 6 / 14 -
Under no circumstances is Endress+Hauser Flowtec AG liable for errors, neither in the Software and in its documentation, nor for
any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the
user. A change in these parameters could lead to different results.
garantiza ni asume responsabilidad alguna sobre la resistencia de materiales a la corrosin seleccionados aqu por la aplicacin descrita.
***El clculo de error se basa en los datos de especificacin de la lnformacin Tcnica (Tl) del caudalmetro seleccionado.
Print date : 17.03.2008 11:49:27 AM COT
Applicator: 10.01.00 / 68
- 7 / 14 -
Under no circumstances is Endress+Hauser Flowtec AG liable for errors, neither in the Software and in its documentation, nor for
any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the
user. A change in these parameters could lead to different results.
Sizing - Caudal
Project : SENA
Customer: C.Project No.: 0
Contact person: --- Phone: --- Fax: ---
eMail: ---
TAG :
Timestamp: 03.03.2008 03:05:23 PM COT Review number: 1
Hoja grficos
Parmetros generales
Fluido : Agua, process Abrasin : No abrasivo
Estado : Liquido Presin atmosfrica : 14.7 psi abs
Carcter : Limpio Estndar : ANSl
Condiciones de operacin
Mnimo Operation Mximo
Caudal solicitado : 3 20 40 l/min
Presin : 60 psi abs
Temperatura : 25 C
Densidad : 62.27 lbs/ft3
Viscosidad : 0.9039 cSt
Presin vapor : 0.2892 0.3974 6.672 psi abs
Presin (min/max) : 60 60 psi abs
Temp. (min/max) : 20 80 C
Caudalmetro : 72F - Prowirl (VFM)
Dimetro nominal : 1/2"
Caudal mnimo : 2.368 l/min
Caudal mximo : 81.943 l/min
Dimetro interno (Sensor) : 0.547 inch
Cdigo pedido : | 7 | 2 | F | 1 | 5 | - | S | K | | | | | | | | | | |
***El clculo de error se basa en los datos de especificacin de la lnformacin Tcnica (Tl) del caudalmetro seleccionado.
Print date : 17.03.2008 11:49:27 AM COT
Applicator: 10.01.00 / 68
- 8 / 14 -
Under no circumstances is Endress+Hauser Flowtec AG liable for errors, neither in the Software and in its documentation, nor for
any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the
user. A change in these parameters could lead to different results.
Sizing - Caudal
Project : SENA
Customer: C.Project No.: 0
Contact person: --- Phone: --- Fax: ---
eMail: ---
TAG :
Timestamp: 03.03.2008 03:05:23 PM COT Review number: 1
lnformacin corrosin
Parmetros generales
Fluido : Agua, process Abrasin : No abrasivo
Estado : Liquido
Carcter : Limpio
lnterpretation of Data, Material(M):
A: resistante, 0.05 mm/y (0.002 pulgadas/y)
B: lnsuficientemente resistente, 0.5 mm/y (0.02 pulgadas/y)
C: No resistente, 1.3 mm/y (0.05 pulgadas/y)
NR: No recomendado
U: Desconocido
lnterpretacin datos, Plsticos(P):
A: resistante, 15% vol. dilatacin/y; 15% prdida de fuerza traccin/y
B: lnsuficientemente resistente, 30% vol. dilatacin/y; 30% prdida de fuerza traccin/y
C: No resistente, 50% vol. dilatacin/y; 60% prdida de fuerza traccin/y
NR: No recomendado
U: Desconocido
Temperatura
Material * Mnimo : 20C Operation : 25C Mximo : 80C
(M) CF3M - A 351 : A A A
(O) Grafito : A A A
(M) Hastelloy C Alloy C-22/2.4602 : A A A
(P) Kalrez : A A A
(P) PTFE : A A A
(M) Acero inoxidable 304/1.4301 : A A A
(M) Acero inoxidable 316L/1.4404 : A A A
(M) Titanio : A A A
(P) Viton : A A A
*El usuario es responsable por la seleccin de los materiales de contacto en funcin de la resistencia a la corrosin. Endress+Hauser Flowtec AG no
garantiza ni asume responsabilidad alguna sobre la resistencia de materiales a la corrosin seleccionados aqu por la aplicacin descrita.
Print date : 17.03.2008 11:49:27 AM COT
Applicator: 10.01.00 / 68
- 9 / 14 -
Under no circumstances is Endress+Hauser Flowtec AG liable for errors, neither in the Software and in its documentation, nor for
any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the
user. A change in these parameters could lead to different results.
Sizing - Caudal
Project : SENA
Customer: C.Project No.: 0
Contact person: --- Phone: --- Fax: ---
eMail: ---
TAG :
Timestamp: 03.03.2008 03:09:26 PM COT Review number: 1
Hoja de clculo dimensiones
Parmetros generales
Fluido : Aire (Gas) Ref. Temperatura : n.a.
Estado : Gas Ref. Presin n.a.
Carcter : Limpio Presin atmosfrica : 14.7 psi abs
Abrasin : No abrasivo Estndar : ANSl
Grupo fluido : Fluido normal
Condiciones de operacin
Mnimo Operation Mximo
Caudal solicitado : 220.462 220.462 220.462 lb/h
Presin : 100 psi abs
Temperatura : 30 C
Densidad : 0.4952 lbs/ft3
Viscosidad : 2.381 cSt
Z-factor : 0.9988
Presin (min/max) : 100 100 psi abs
Temp. (min/max) : 30 30 C
Caudalmetro : 65F - t-mass (TMF)
Dimetro nominal : 1"
Caudal mnimo : 4.245 lb/h
Calibrated Flow : 424.488 lb/h
Caudal mximo : 2 311.1 lb/h
Dimetro interno (Sensor) : 0.957 inch
Presin mnima : Cl 150 ANSl / 316L/1.4404 Brida B16.5
Material (sensor) * : SS 1.4404 / 316L
PED ** : Segn las condiciones de proceso y fluido especificados, el equipo est en el mbito del articulo 3.3 de la PED. Por
este motivo, Applicator no propone ningn equipo con opcin PED.
Cdigo pedido : | 6 | 5 | F | 2 | 5 | - | A | K | | | | 1 | | | | | | |
Dimensionado y resutados de clculo
Mnimo Operation Mximo
Caudal solicitado : 220.462 220.462 220.462 lb/h
Prdida de carga : 0 0.011 0 psi
Velocidad (tubos de medida) : 0 24.77 0 ft/s
lncertidumbre en volmen*** : n.a. n.a. n.a. %
lncertidumbre en masa*** : 1.5 1.5 1.5 %
Nmero de Reynolds : 77 050.5
Advertencias / Mensajes de error
*El usuario es responsable por la seleccin de los materiales de contacto en funcin de la resistencia a la corrosin. Endress+Hauser Flowtec AG no
garantiza ni asume responsabilidad alguna sobre la resistencia de materiales a la corrosin seleccionados aqu por la aplicacin descrita.
** La categora PED es una recomendacin E+H y depende de la categora del fluido, datos de proceso y de la max. presin permisible del factor de
presin seleccionado.Los fluidos de la base de datos del Applicator estn clasificados segn 67/548/EWG.
***El clculo de error se basa en los datos de especificacin de la lnformacin Tcnica (Tl) del caudalmetro seleccionado.
Print date : 17.03.2008 11:49:27 AM COT
Applicator: 10.01.00 / 68
- 10 / 14 -
Under no circumstances is Endress+Hauser Flowtec AG liable for errors, neither in the Software and in its documentation, nor for
any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the
user. A change in these parameters could lead to different results.
Sizing - Caudal
Project : SENA
Customer: C.Project No.: 0
Contact person: --- Phone: --- Fax: ---
eMail: ---
TAG :
Timestamp: 03.03.2008 03:09:26 PM COT Review number: 1
Dimensiones tres dimetros (Trisize)
Parmetros generales
Fluido : Aire (Gas) Ref. Temperatura : n.a.
Estado : Gas Ref. Presin n.a.
Carcter : Limpio Presin atmosfrica : 14.7 psi abs
Abrasin : No abrasivo Estndar : ANSl
Grupo fluido : Fluido normal
Condiciones de operacin
Mnimo Operation Mximo
Caudal solicitado : 220.462 220.462 220.462 lb/h
Presin : 100 psi abs
Temperatura : 30 C
Densidad : 0.4952 lbs/ft3
Viscosidad : 2.381 cSt
Z-factor : 0.9988
Presin (min/max) : 100 100 psi abs
Temp. (min/max) : 30 30 C
Dimensionado y resutados de clculo
Dimetro inferior Dimetro nominal estndar Dimetro superior
Dimetro interno (Sensor) : 0.547 0.957 1.5 inch
Dimetro nominal : 1/2" 1" 1 1/2"
Presin mnima : Cl 150 ANSl / 316L/1.4404 Cl 150 ANSl / 316L/1.4404 Cl 150 ANSl / 316L/1.4404
Caudal mnimo : 1.389 4.245 10.435 lb/h
Calibrated Flow : 138.894 424.488 1 043.525 lb/h
Caudal mximo : 756.199 2 311.1 5 681.41 lb/h
Prdida de carga a caudal mn. : 0 0 0 psi
Prdida de carga a caudal nom. : 0.199 0.011 0.001 psi
Prdida de carga a caudal mx. : 0 0 0 psi
Velocidad (tubos de medida) a caudal mn. : 0 0 0 ft/s
Velocidad (tubos de medida) a caudal nom. : 75.72 24.77 10.08 ft/s
Velocidad (tubos de medida) a caudal mx. : 0 0 0 ft/s
lncertidumbre en volmen a caudal mn.
solicitado*** :
n.a. n.a. n.a. %
lncertidumbre en volmen a caudal nom.
Solicitado*** :
n.a. n.a. n.a. %
lncertidumbre en volmen a caudal mx.
solicitado*** :
n.a. n.a. n.a. %
lncertidumbre en masa a caudal mn.
solicitado*** :
n.a. 1.5 1.5 %
lncertidumbre en masa a caudal nom.
Solicitado*** :
n.a. 1.5 1.5 %
lncertidumbre en masa a caudal mx.
solicitado*** :
n.a. 1.5 1.5 %
Nmero de Reynolds : 134 700 77 050.5 49 142.5
*El usuario es responsable por la seleccin de los materiales de contacto en funcin de la resistencia a la corrosin. Endress+Hauser Flowtec AG no
garantiza ni asume responsabilidad alguna sobre la resistencia de materiales a la corrosin seleccionados aqu por la aplicacin descrita.
Print date : 17.03.2008 11:49:27 AM COT
Applicator: 10.01.00 / 68
- 11 / 14 -
Under no circumstances is Endress+Hauser Flowtec AG liable for errors, neither in the Software and in its documentation, nor for
any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the
user. A change in these parameters could lead to different results.
***El clculo de error se basa en los datos de especificacin de la lnformacin Tcnica (Tl) del caudalmetro seleccionado.
Print date : 17.03.2008 11:49:27 AM COT
Applicator: 10.01.00 / 68
- 12 / 14 -
Under no circumstances is Endress+Hauser Flowtec AG liable for errors, neither in the Software and in its documentation, nor for
any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the
user. A change in these parameters could lead to different results.
Sizing - Caudal
Project : SENA
Customer: C.Project No.: 0
Contact person: --- Phone: --- Fax: ---
eMail: ---
TAG :
Timestamp: 03.03.2008 03:09:26 PM COT Review number: 1
Hoja grficos
Parmetros generales
Fluido : Aire (Gas) Abrasin : No abrasivo
Estado : Gas Presin atmosfrica : 14.7 psi abs
Carcter : Limpio Estndar : ANSl
Condiciones de operacin
Mnimo Operation Mximo
Caudal solicitado : 220.462 220.462 220.462 lb/h
Presin : 100 psi abs
Temperatura : 30 C
Densidad : 0.4952 lbs/ft3
Viscosidad : 2.381 cSt
Z-factor : 0.9988
Presin (min/max) : 100 100 psi abs
Temp. (min/max) : 30 30 C
Caudalmetro : 65F - t-mass (TMF)
Dimetro nominal : 1"
Caudal mnimo : 4.245 lb/h
Calibrated Flow : 424.488 lb/h
Caudal mximo : 2 311.1 lb/h
Dimetro interno (Sensor) : 0.957 inch
Cdigo pedido : | 6 | 5 | F | 2 | 5 | - | A | K | | | | 1 | | | | | | |
***El clculo de error se basa en los datos de especificacin de la lnformacin Tcnica (Tl) del caudalmetro seleccionado.
Print date : 17.03.2008 11:49:27 AM COT
Applicator: 10.01.00 / 68
- 13 / 14 -
Under no circumstances is Endress+Hauser Flowtec AG liable for errors, neither in the Software and in its documentation, nor for
any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the
user. A change in these parameters could lead to different results.
Sizing - Caudal
Project : SENA
Customer: C.Project No.: 0
Contact person: --- Phone: --- Fax: ---
eMail: ---
TAG :
Timestamp: 03.03.2008 03:09:26 PM COT Review number: 1
lnformacin corrosin
Parmetros generales
Fluido : Aire (Gas) Abrasin : No abrasivo
Estado : Gas
Carcter : Limpio
lnterpretation of Data, Material(M):
A: resistante, 0.05 mm/y (0.002 pulgadas/y)
B: lnsuficientemente resistente, 0.5 mm/y (0.02 pulgadas/y)
C: No resistente, 1.3 mm/y (0.05 pulgadas/y)
NR: No recomendado
U: Desconocido
lnterpretacin datos, Plsticos(P):
A: resistante, 15% vol. dilatacin/y; 15% prdida de fuerza traccin/y
B: lnsuficientemente resistente, 30% vol. dilatacin/y; 30% prdida de fuerza traccin/y
C: No resistente, 50% vol. dilatacin/y; 60% prdida de fuerza traccin/y
NR: No recomendado
U: Desconocido
Temperatura
Material * Mnimo : 30C Operation : 30C Mximo : 30C
(P) EPDM : A A A
(M) Hastelloy C Alloy C-22/2.4602 : A A A
(P) Kalrez : A A A
(P) PEEK : U U U
(M) Acero inoxidable 316L/1.4404 : A A A
(P) Viton : A A A
*El usuario es responsable por la seleccin de los materiales de contacto en funcin de la resistencia a la corrosin. Endress+Hauser Flowtec AG no
garantiza ni asume responsabilidad alguna sobre la resistencia de materiales a la corrosin seleccionados aqu por la aplicacin descrita.
Print date : 17.03.2008 11:49:27 AM COT
Applicator: 10.01.00 / 68
- 14 / 14 -
Under no circumstances is Endress+Hauser Flowtec AG liable for errors, neither in the Software and in its documentation, nor for
any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the
user. A change in these parameters could lead to different results.

Das könnte Ihnen auch gefallen