Sie sind auf Seite 1von 48

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Subpart A - General Scope of part. Definitions. Class locations. Incorporation be reference. lines. Gathering Outer continental shelf pipelines Petroleum gas systems. General. Conversion to service subject to this part. Rules of regulatory construction. Customer notification. 192.1 192.3 192.5 192.7 192.9 192.10 192.11 192.13 192.14 192.15 192.16 N N N N N Y N N N N N Y Y Y Y Y Y Y N N Y N Y N Y Y Y N Y

Establishes jurisdictional responsibility.

N N Y N N Y N N Y N N Y N N Y

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Subpart B - Materials Scope. General. New steel pipe Used steel pipe New or used steel pipe Steel pipe not previously used New steel pipe that has been cold expanded Reserved New plastic pipe Used plastic pipe Pipe of a diameter not listed in a specification Reserved Marking of materials. Transportation of pipe. 192.51 192.53 192.55(a) 192.55(b) 192.55(c) 192.55(d) 192.55(e) 192.57 192.59(a) 192.59(b) 192.59(c) 192.61 192.63 192.65 N N N N N N N N N N N N Y Y Y Y Y Y N Y Y Y Y Y Y

N N Y

Not applicable N N Y Y N N Y Y N N Y Y Not applicable N N Y Y N N Y Y

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Subpart C - Pipe Design Scope. General. Design formula for steel pipe. Yield strength (S) for steel pipe. Nominal wall thickness (t) for steel pipe. Design factor (F) for steel pipe. Longitudinal joint factor (E) for steel pipe. Temperature derating factor (T) for steel pipe Reserved Reserved Design of plastic pipe. Design limitations for plastic pipe. Design of copper pipe. 192.101 192.103 192.105 192.107 192.109 192.111 192.113 192.115 192.117 192.119 192.121 192.123 192.125 N N Y N N Y N N Y N N Y N N Y N N Y N N Y N N Y N Y Y Y Y Y Y Y

Not applicable Not applicable N N Y Y N N Y Y N N Y Y

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Subpart D - Design of Pipeline Components Scope. General requirements. Qualifying metallic components. Valves Flanges and flange accessories. Standard fittings. Passage of internal inspection devices. Tapping. Components fabricated by welding. Welded branch connections. Extruded outlets. Flexibility. Supports and anchors Strain, forces, vibration Supports and anchors End force 192.141 192.143 192.144 192.145 192.147 192.149 192.150 192.151 192.153 192.155 192.157 192.159 192.161(a) 192.161(b) N N Y N N Y N N Y N N Y N N Y N N Y N N Y N N Y N N Y N N Y N N Y N N Y N N Y N N Y Y Y Y

Y Y Y Y Y Y Y Y Y Y

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Supports and anchors Designed and installed Supports and anchors Designed and installed Supports and anchors 50 % or more of SMYS Supports and anchors Fixed object Supports and anchors Connection to new branches Compressor stations: Design and construction. Compressor stations: Liquid removal. Compressor stations: Emergency shutdown. Compressor stations: Pressure limiting devices. Compressor stations: Additional safety equipment. Compressor stations: Ventilation.

192.161(c)

Main O&M

192.161(c)

Support and anchor maintenance Transmission line O&M Support and anchor maintenance

Y Y Y

Y Y

Y Y Y

192.161(d) 192.161(e) 192.161(f)

N N Y N N Y N N Y

Y Y Y

192.163 192.165 192.167 192.169 192.171

N N Y N N Y N N Y N N Y N N Y

Y Y Y Y Y

192.173

N N Y

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Pipe-type and bottle-type holders. Additional provisions for bottle-type holders. Transmission line valves. Distribution line valves. Vaults: Structural design requirements. Vaults: Accessibility. Vaults: Sealing, venting and ventilation. Vaults: Drainage and waterproofing. Design pressure of plastic fittings. Valve installation in plastic pipe. Protection against accidental overpressure. of gas, highPressure pressure distribution systems. Requirements for design of pressure relief and limiting devices. Materials

192.175 192.177 192.179 192.181 192.183 192.185 192.187 192.189 192.191 192.193 192.195 192.197

N N Y N N Y N N Y N N Y N N Y N N Y N N Y N N Y N N Y N N Y N N Y N N Y

Y Y Y Y Y Y Y Y Y Y Y Y

192.199

N N Y

192.199(a)

N N Y

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Valves and valve seats Installed for ready operation and testing Supports Discharge stacks, vents, or outlet ports Installed to prevent hammering and impairment of relief capacity and installed Designed to prevent any single incident capacity of Required pressure relieving and limiting stations Installation and set point More than one pressure regulating or compressor station Low pressure distribution system Instrument, control, sampling pipe and components Applicability Materials and design

192.199(b) 192.199(c) 192.199(d) 192.199(e) 192.199(f)

Pressure relief & limiting device maintenance

N N Y Y Y Y N N Y N N Y

Y Y Y Y Y Y Y

Pressure relief & limiting device maintenance Pressure relief & limiting device maintenance

Y Y Y

192.199(g) 192.201

Y Y Y

Y Y

192.201(a) 192.201(b)

Pressure control device maintenance

Y Y Y N N Y

Y Y Y

192.201(c) 192.203

N N Y N N Y

Y Y

192.203(a) 192.203(b)

N N Y N N Y

Y Y

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Subpart E - Welding of Steel in Pipelines Scope Welding - General. Welding by qualified welder with qualified procedures Record of procedures Qualification of welders. Limitations on welders. Qualifications based on NDE Engaged in welding in proceeding 6 months A welder qualified under 192.227(a) A welder qualified under 192.227(b) Protection from weather. Miter joints. Preparation for welding. Inspection and test of welds. Visual inspection of welds NDE of welds 192.221 192.225 192.225(a) 192.225(b) 192.227 192.229 192.229(a) 192.229(b) 192.229(c) 192.229(d) 192.231 192.233 192.235 192.241 192.241(a) 192.241(b) Welding Welding Welding N N Y Welding Y Y Y N N Y N N Y N N Y N N Y N N Y N N Y Y Y Y Y Y Y Y Y Y N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y

Welding - Visual inspection Welding - NDE

Y Y Y Y Y Y

Y Y Y Y

Y Y

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Acceptability of welds Acceptability of welds Nondestructive testing. Repair or removal of defects. Removal & repair of unacceptable welds Repair process & inspection Repair process & inspection Repair process & inspection Repair in a previously repaired area Repair in a previously repaired area Repair in a previously repaired area

192.241(c) 192.241(c) 192.243 192.245 192.245(a) 192.245(b) 192.245(b) 192.245(b) 192.245(c) 192.245(c) 192.245(c)

Welding - NDE Welding - Visual inspection Welding - NDE

Y Y Y Y Y Y Y Y Y

Y Y Y Y Y Y

Y Y Y

Welding Welding Welding - Visual inspection Welding - NDE Welding Welding - Visual inspection Welding - NDE

Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y

Y Y Y Y Y Y Y Y Y Y Y Y Y Y

Y Y Y Y Y Y Y

10

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Subpart F - Joining of Materials Other Than by Welding Scope General. Pipeline design & installation 192.271 192.273 192.273(a) N N Y N N Y N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y

Joining in accordance with written procedures Joint inspection Cast iron pipe. Ductile iron pipe. Copper pipe. Plastic pipe. Disturbance of plastic pipe joints Solvent cement joints Heat-fusion joints Adhesive joints

192.273(b) 192.273(c) 192.275 192.277 192.279 192.281 192.281(a) 192.281(b) 192.281(c) 192.281(d)

Joining Joining inspection Joining cast iron pipe Joining ductile iron pipe Joining copper pipe Joining plastic pipe Joining plastic pipe solvent cement joints Joining plastic pipe heat-fusion joints Joining plastic pipe adhesive joints

Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y

Y Y Y Y Y Y Y Y Y Y Y Y

Y Y Y Y Y Y Y Y

Y Y Y Y

11

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Mechanical joints Plastic pipe: qualifying joining procedures. Plastic pipe: qualifying persons to make joints. Plastic pipe: inspection of joints.

192.281(e) 192.283 192.285 192.287

Joining plastic pipe mechanical joints

Y Y Y N N Y N N Y N N Y

Y Y Y Y Y

12

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Subpart G - General Construction Requirements for Transmission Lines and Mains Scope Compliance with specifications and standards. Compliance with specifications and standards. Inspection: General Inspection: General 192.301 192.303 Main O&M Compliance with specifications Transmission line O&M and standards. Compliance with specifications Main O&M - Inspection and standards. Inspection Transmission Line O&M Inspection - Inspection Main O&M - Inspection Inspection of materials Transmission Line O&M Inspection of - Inspection materials Main O&M Transmission line O&M Welding Welding - NDE Main O&M Transmission line O&M Main O&M N N Y Y Y Y N Y Y

192.303

Y Y Y

192.305 192.305

Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y

Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y

Y Y Y

Inspections of materials. 192.307 Inspections of materials. 192.307 Repair of steel pipe. Repair of steel pipe. Repair of steel pipe. Repair of steel pipe. Repair of plastic pipe. Repair of plastic pipe. Bends and elbows. 192.309 192.309 192.309 192.309 192.311 192.311 192.313

Y Y Y Y Y

13

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Bends and elbows. Wrinkle bends in steel pipe. Wrinkle bends in steel pipe. Protection from hazards. Protection from hazards Transmission lines hoop stress of 20% or more of SMYS Backfilling Backfilling Installation of offshore pipe Installation of plastic pipe. Installation of plastic pipe. Casings. Casings. Underground clearances. line Transmission clearances Main clearances Plastic transmission lines & mains, protection from heat

192.313 192.315 192.315 192.317 192.317 192.319(a)

Transmission line O&M Main O&M Transmission line O&M Main O&M Transmission line O&M Transmission line O&M

Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y

Y Y Y Y Y Y Y Y

Y Y

192.319(b) 192.319(b) 192.319(c) 192.321 192.321 192.323 192.323 192.325 192.325(a) 192.325(b) 192.325(c)

Main O&M Transmission line O&M Offshore pipeline O&M Main O&M Transmission line O&M Main O&M Transmission line O&M Transmission line O&M Main O&M Main O&M

Y Y Y Y Y Y Y

Y Y Y Y Y Y Y

Y Y Y Y Y Y Y

Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y

Y Y Y Y Y

Y Y Y Y Y Y Y Y Y

14

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Plastic transmission lines & mains, protection from heat Pipe-type and bottle-type holder clearances Pipe-type and bottle-type holder clearances Cover. Transmission line cover Main cover Protection when minimum cover not met Protection when minimum cover not met Main cover less than 24 inches Pipe installed in navigable river, stream or harbor Pipe installed in navigable river, stream or harbor Pipe installed offshore, except in the Gulf of Mexico Pipelines installed in the Gulf of Mexico and its inlets

192.325(c)

Transmission line O&M

Y Y Y

192.325(d) 192.325(d) 192.327 192.327(a) 192.327(b) 192.327(c) 192.327(c) 192.327(d) 192.327(e) 192.327(e) 192.327(f)

Main O&M Transmission line O&M

Y Y Y Y Y Y

Y Y Y Y

Transmission line O&M Main O&M Main O&M Transmission line O&M Main O&M Main O&M Transmission line O&M Offshore pipeline installation Offshore pipeline installation

Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y

Y Y Y Y Y Y Y Y Y Y Y Y

Abnormal operating condition Abnormal operating condition Abnormal operating condition Abnormal operating condition Abnormal operating condition Abnormal operating condition

Y Y

Abnormal operating condition Abnormal operating condition

192.327(g)

Y Y Y

Abnormal operating condition

15

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

16

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Subpart H - Customer Meters, Service Regulators, and Service Lines Scope Customer meters and regulators: Location. Customer meters and regulators: Protection from damage. Customer meters and regulators: Installation. Customer meter installations: Operating pressure. Service lines: Installation. Depth Support and backfill Grading for drainage Protection against strain and external loading Installation in buildings Service lines: Valve requirements. 192.351 192.353 192.355 N N Y Y Y Y Y Y Y N Y Y Y Y

Meter installation Meter installation

Y Y

192.357 192.359

Meter installation

Y Y Y N N Y

Y Y Y

192.361 192.361(a) 192.361(b) 192.361(c) 192.361(d) 192.361(e) 192.363

Service line O&M Service line O&M Service line O&M Service line O&M Service line O&M

Y Y Y Y

Y Y Y Y

Y Y Y Y

Y Y Y Y

Y Y Y Y

Construction versus O&M Construction versus O&M Construction versus O&M Construction versus O&M Construction versus O&M

Y Y Y N N Y

Y Y Y

17

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Service lines: Location of 192.365 valves. Service lines: 192.367 Requirements for connections to main piping. Service lines: Connections to cast iron or ductile iron.Steel. Service lines: Service lines: Cast iron and ductile iron. Service lines: Plastic. Service lines: Copper New service lines not in use. Service lines: Excess flow valve performance standards. Industry specification External protective coating Identification of excess flow valves Contaminants Location of excess flow valves 192.369 192.371 192.373 192.375 192.377 192.379 192.381

Service line O&M Service line O&M

Y Y Y Y Y Y

Y Y Y Y

Service line O&M

Y Y Y N N Y Y Y Y Y Y Y Y Y Y Y Y Y

Y Y Y Y Y Y Y Y Y Y Y

Service line O&M Service line O&M Service line O&M Service line O&M

192.381(a) 192.381(b) 192.381(c) 192.381(e) 192.381(d)

Service line O&M

N N Y N N Y Y Y Y N N Y Y Y Y

Y Y Y Y Y Y Y

Service line O&M

18

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Excess flow valve customer notification

192.383

N N Y

19

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Subpart I Requirements for Corrosion Control Scope Applicability to converted pipelines. General. Buried or submerged pipelines installed after July 31, 1971 Protection from external corrosion External coating meeting 192.461 Cathodic protection system designed to meet this subpart Exemption from 192.455(a) Exemption from 192.455(a): Copper & temporary pipelines Externally coated pipeline Use of aluminum

192.451 192.452 192.453 192.455

N N Y N N Y N N Y

N Y Y

Specification Personnel qualification

192.455(a) 192.455(a)(1) 192.455(a)(2) Corrosion control external Corrosion control external Corrosion control external Corrosion control external Corrosion control external External coating O&M Cathodic protection system O&M Monitor for corrosion Monitor for corrosion Cathodic protection system O&M Y Y Y Y Y Y Y Y Y Y Y Y

192.455(b) 192.455(c)

Y Y Y Y Y Y

Y Y Y Y

Y Y

192.455(d)

Y Y Y

Y Y

192.455(e)

N N Y

Specification

20

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Applicability to metal alloy fittings on plastic pipelinescorrosion External control: Buried or submerged pipelines Transmission lines

192.455(f) 192.457

N N Y

Specification

192.457(a)

Corrosion control external Corrosion control external Corrosion control external

Active corrosion pipelines other than cast and ductile iron Active corrosion pipelines other than cast and ductile iron Active corrosion Examination of buried pipeline when exposed. Examination of buried pipeline when exposed. External corrosion control: Protective coating. Application of coating Electrically insulating type coating

192.457(b)

192.457(b)

Cathodic protection system O&M Catodic protection system O&M Monitor for corrosion

Y Y Y

Y Y Y

Y Y

Y Y Y

Y Y

192.457(c) 192.459 192.459 192.461 192.461(a) 192.461(b)

Corrosion control external Corrosion control external

N N Y Monitor for Y Y Y corrosion Remedial action Y Y Y

Y Y Y Y Y

Definition Y Y

Corrosion control external

External coating Y Y Y O&M N N Y

Y Y Y

Y Specification

21

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Coating inspection

192.461(c)

Protection from damage 192.461(d) Protection from damage 192.461(e) External corrosion control: Cathodic protection. External corrosion control: Monitoring. Testing at intervals not exceeding 15 months Inspection of rectifiers or other impressed current power source Reverse current switch, diode, and interface bond check Remedial action to correct deficiencies Reevaluation of unprotected pipelines Reevaluation of unprotected pipelines 192.463 192.465 192.465(a) 192.465(b)

Corrosion control external Corrosion control external Corrosion control external

External coating Y Y Y inspection External coating Y Y Y O&M External coating Y Y Y O&M N N Y

Y Y Y Y Y Y Y

Y Y Y Specification

Corrosion control external Corrosion control external Corrosion control external Corrosion control external Corrosion control external Corrosion control external

Monitor for corrosion Monitor for corrosion Monitor for corrosion Cathodic protection system O&M Monitor for corrosion Cathodic protection system O&M

Y Y Y Y Y Y

Y Y Y Y

Y Y

192.465(c)

Y Y Y

Y Y

192.465(d)

Y Y Y

Y Y

192.465(e) 192.465 (e)

Y Y Y Y Y Y

Y Y Y Y

Y Y

22

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

External corrosion control: Electrical isolation. isolation Electrical Insulating devices

192.467 192.467(a) 192.467(b) N N Y Y Y Y Y Y Y Specification Y

Corrosion control external Corrosion control external Corrosion control external Corrosion control external Corrosion control external

Electrical isolation from metallic casings

192.467(c)

Electrical isolation from 192.467(c) metallic casings, other measures Inspection and electrical 192.467(d) tests Installation of insulating device Proximity to fault currents corrosion External control: Test stations. External corrosion control: Test leads. Test lead connection 192.467(e)

Cathodic protection system O&M Cathodic protection system O&M Cathodic protection system O&M Cathodic protection system O&M Cathodic protection system O&M

Y Y Y

Y Y

Y Y Y

Y Y

Y Y Y

Y Y

Y Y Y

Y Y

Specification

192.467(f) 192.469 192.471 192.471(a) Corrosion control external Corrosion control external

N N Y N N Y

Y Y

Specification Specification

Cathodic protection system O&M

Y Y Y

Y Y

23

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Test lead attached to 192.471(b) minimize adverse affects Bared test lead and bared metallic area coating External corrosion control: Interference currents. Stray current program Impressed current type cathodic protection system installation Internal corrosion control: General provisions. Minimize internal corrosion of removed Inspection pipe Adjacent pipe Replacement Steps to minimize internal corrosion Storage of gas containing hydrogen sulfide in holders 192.471(c)

Corrosion control external Corrosion control external

Cathodic protection system O&M Cathodic protection system O&M

Y Y Y

Y Y

Y Y Y

Y Y

192.473 192.473(a) 192.473(b) N N Y Y Y Y Y Y Y Program Y

Corrosion control external

Cathodic protection system O&M

192.475 192.475(a) 192.475(b) 192.475(b)(1) 192.475(b)(2) 192.475(b)(3) 192.475(c) Corrosion control internal control Corrosion internal Corrosion control internal Corrosion control internal control Corrosion internal Pipeline O&M Monitor for corrosion Monitor for corrosion Pipeline O&M Pipeline O&M Y Y Y Y Y Y Y Y Y Y Y

Y Y Y

Y Y

N N Y

Specification

24

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Internal corrosion control: Monitoring.

192.477

Corrosion control internal

Monitor for corrosion

Y Y Y

Y Y

Evaluation of the coupons is not a covered task. However, activities to be able to insert and retrieve the coupons may be covered tasks.

Atmospheric corrosion control: General. Pipelines installed after July 31, 1971 Pipelines installed before August 1, 1971 Determine areas of atmospheric corrosion Take remedial action

192.479 192.479(a) 192.479(b) 192.479(b)(1) 192.479(b)(2) Corrosion control atmospheric Corrosion control atmospheric Corrosion control atmospheric Corrosion control atmospheric Corrosion control atmospheric Monitor for corrosion Pipeline O&M Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Corrosion control atmospheric External coating Y Y Y - O&M Y Y Y

Clean and coat or jacket 192.479(b)(3) Pipeline reevaluation Remedial action Remedial measures: General. Protective coating 192.481 192.481 192.483 192.483(a)

External coating Y Y Y - O&M Monitor for Y Y Y corrosion Y Y Y

Corrosion control external

External coating Y Y Y O&M

Y Y

25

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Cathodic protection

192.483(b)

Corrosion control external Corrosion control external

Repaired pipe

192.483(c)

Cathodic protection system O&M Cathodic protection system O&M

Y Y Y

Y Y

Y Y Y

Y Y

Remedial measures: Transmission lines. General corrosion: Transmission lines Localized corrosion pitting: Transmission lines Localized corrosion pitting: Transmission lines Localized corrosion pitting: Transmission lines Strength of pipe Remedial measures: Distribution lines General corrosion except cast iron or ductile iron General corrosion except cast iron or ductile iron Localized corrosion pitting

192.485 192.485(a) 192.485(a) 192.485(b) 192.485(b) 192.485(c) 192.487 192.487(a) 192.487(a) 192.487(b) Corrosion control Corrosion control Corrosion control Corrosion control Corrosion control Corrosion control Corrosion control Transmission line - O&M Pressure control Transmission line - O&M Pressure Control Y Y Y Y Y Y Y Y Y Y Y Y N N Y Y Y Y Y Y Y Y Y Y Specification

Distribution line - Y Y Y O&M Pressure Y Y Y control Distribution line - Y Y Y O&M

Y Y Y Y Y Y

26

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Remedial measures: Cast-iron and ductileiron pipelines. General graphitization Localized graphitization Corrosion control records.

192.489

192.489(a) 192.489(b) 192.491

Corrosion control Corrosion control

Distribution line - Y Y Y O&M Distribution line - Y Y Y O&M Y Y Y

Y Y Y Y N Specification

27

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Subpart J - Test Requirements Scope. General Requirements. Operate a new segment or return to service a segment substantiate Tested to MAOP Potentially hazardous leak medium Test Hoop stress limitations Tie in joints Steel pipeline, hoop stress of 30 percent or more of SMYS. Strength testing in accordance with this section Compressor station, regulator station and measuring station Test duration 192.501 192.503 192.503(a) 192.503(a)(1) 192.503(a)(2) 192.503(b) 192.503(c) 192.503(d) 192.505 Pressure test Leak repair N N Y N N Y N N Y Y Y Y Y Y Y N N Y N N Y N N Y N N Y N N Y Y Y Y N N Y N Y Test medium specification Test hoop stress limitation specification Specifies tie in joints that do and do not require testing

Introduction

192.505(a)

Pressure test

Y Y Y

Y Y

192.505(b)

Pressure test

Y Y Y

Y Y

192.505(c)

Pressure test

Y Y Y

Y Y

28

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Manufacturer certified component other than pipe Preinstallation strength test Hoop stress less than 30 percent of SMYS, and at or above 100 p.s.i. Potentially hazardous leaks Test medium, 20 percent or more of SMYS Leak test Leak survey Test duration Test requirements for pipelines to operate below 100 p.s.i.g. Potentially hazardous leaks Test pressure Test requirements for service lines. Leak test

192.505(d) 192.505(e) 192.507 Pressure test

N N Y N N Y Y Y Y

Y Y Y Y Y

192.507(a) 192.507(b) 192.507(b)(1) 192.507(b)(2) 192.507(c) 192.509

Leak repair

Y Y Y N N Y

Y Y Y Y Y Y Y Y Y Y Y

Y Introduction Y Y Y

Leak repair Leak survey Pressure test Pressure test

Y Y Y Y

Y Y Y Y

Y Y Y Y

192.509(a) 192.509(b) 192.511 192.511(a)

Leak repair Pressure test

Y Y Y

Y Y

Pressure test

Y Y Y

Y Y

29

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Service line intended to be operated at a pressure of at least 1 p.s.i. but not more than 40 p.s.i. line intended to Service be operated at a pressure of more than 40 p.s.i. Test requirements for plastic pipelines. Tested in accordance with this section Potentially hazardous leaks Test pressure Temperature of thermoplastic material Environmental protection and safety requirements. Safety requirements Environmental requirements Records.

192.511(b)

Pressure test

Y Y Y

Y Y

192.511(c)

Pressure test

Y Y Y

Y Y

192.513 192.513(a) 192.513(b) 192.513(c) 192.513(d) 192.515 192.515(a) 192.515(b) 192.517

Pressure test Pressure test Leak repair Pressure test N N Y Y Specification Y Y Y Y Y

Y Y Y Y Y Y Y Y Y

N N N

30

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Subpart K - Uprating Scope. General requirements. Pressure increases Check for leaks Repair of leaks Records Written plan Limitation on increase in MAOP Hoop stress of 30 percent or more of SMYS in steel pipelines. Requirements of this section Review of design, operating, and maintenance and testing Repairs, replacements or alterations Repairs, replacements or alterations Pipeline constructed before September 12, 1970 192.551 192.553 192.553(a) 192.553(a)(1) 192.553(a)(2) 192.553(b) 192.553(c) 192.553(d) 192.555 N N Y Pressure Control Leak survey Leak repair Y Y Y N N N Y Y Y N N N Y Y Y Y Y Y N Y Y Y Y Y Y N Y Y Y Y Y Record keeping Procedure Specification

192.555(a) 192.555(b)(1)

N N Y N N Y

Y Y

192.555(b)(2) 192.555(b)(2) 192.555(c)

Main O&M Transmission Line O&M

Y Y Y Y Y Y N N Y

Y Y Y Y Y

Y Y

31

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Not qualified under paragraph (c) Not qualified under paragraph (c) Increase in increments Hoop stress less than 30 percent of SMYS Requirements of this section

192.555(d)(1) 192.555(d)(2) 192.555(e) 192.557 192.557(a)

Pressure test

Y Y Y N N Y

Y Y Y Y Y

Pressure control

Y Y Y

N N Y

Y Y Y Y Y

Review of design, operating, and maintenance history Leakage survey Leakage survey Repairs, replacements, or alterations Repairs, replacements, or alterations Repairs, replacements, or alterations Reinforce or anchor offsets, bends and dead ends

192.557(b)(1)

N N Y

192.557(b)(2) 192.557(b)(2) 192.557(b)(3) 192.557(b)(3) 192.557(b)(3) 192.557(b)(4)

Leak survey Leak repair Main O&M Service Line O&M Transmission Line O&M Main O&M

Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y

Y Y Y Y Y Y Y Y Y Y Y Y

Y Y Y Y Y Y

32

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Reinforce or anchor offsets, bends and dead ends Isolation Service regulators Increase in increments Incomplete records for cast iron or ductile iron pipelines Measure actual cover

192.557(b)(4)

Transmission Line O&M

Y Y Y

Y Y

192.557(b)(5) 192.557(b)(6) 192.557(c) 192.557(d)(1)

Pressure control Service line O&M Pressure control

Y Y Y N

Y Y Y N

Y Y Y Y

Y Y Y Y Y Y Y

Y Y

192.557(d)(2)

Cast and ductile iron O&M

Y Y Y

Y Y

The act of taking or making the measurement is not a covered task. However, activities to be able to take or make the measurement may be covered tasks. The act of determining the wall thickness is not a covered task. However, activities to be able to take the measurement may be covered tasks. Specification

Determine wall thickness 192.557(d)(3)

Cast and ductile iron O&M

Y Y Y

Y Y

Cast iron bursting tensile 192.557(d)(4) strength

N N Y

33

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Subpart L - Operations Scope. General provisions. Operation in accordance with this subpart Records Required amendment to plan Procedural manual General. Operating, maintaining and repairing the pipeline Controlling corrosion in accordance with Subpart I Availability of construction records, maps, operating history Gathering data for incident reporting Starting up and shutting down any part of the pipeline Maintaining compressor stations, including isolation and purging 192.601 192.603 192.603(a) 192.603(b) 192.603(c) 192.605 192.605(a) 192.605(b)(1) 192.605(b)(2) 192.605(b)(3) N N Y N N Y Y Y Y Y Y N N Y N N

Y N Y N N Y N N Y N N Y

N N N N

192.605(b)(4) 192.605(b)(5) Pipeline startup and shutdown Compressor station maintenance

Y N Y Y Y Y

N Y Y Y

192.605(b)(6)

Y Y Y

34

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Starting, operating and shutting down compressor units Periodic review of work done by operating personnel Precautions in excavated trenches Testing and inspection of pipe-type and bottle-type holders Detection of external corrosion Sampling and testing of gas

192.605(b)(7)

Compressor units: starting, operating and shutting down

Y Y Y

192.605(b)(8)

Y N Y

192.605(b)(9) 192.605(b)(10)

Y Y Y

192.605(b)(10) Corrosion control (i) external 192.605(b)(ii) Corrosion control internal

Monitor for corrosion Monitor for corrosion

Y Y Y Y Y Y

Y Y Y Y

Y Y Determination of dew point is not a covered task. However, activities to obtain the sample may be covered tasks. Y

Pressure limiting devices 192.605(b)(iii) Abnormal operation, 192.605(c) transmission lines Recognition of potential 192.605(d) safety-related conditions Surveillance, emergency 192.605(e) response, and accident investigation

Pressure control device maintenance Abnormal operations remedial action Emergency response

Y Y Y Y Y Y Y Y Y N N Y

Y Y Y Y Y

Y Y Y

See 192.613(a), 192.615, 192.617

35

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Reserved Change in class location: Required study Confirmation or revision of MAOP Hoop stress not commensurate with present class location MAOP if segment previously tested in place Corresponding hoop stress in accordance Testing with Subpart J Establishing MAOP Confirmed or revised MAOP may not exceed previous MAOP Application of 192.553 & 192.555 Confirmation or revision of MAOP with 18 months Pipelines in the Gulf of Mexico and its inlets. Inspection between October 3, 1989 and November 16, 1992

192.607 192.609 192.611 192.611(a)

N N Y

N N Y

192.611(a)(1) 192.611(a)(2) 192.611(a)(3) 192.611(a)(3) 192.611(b)

N N Y N N Y N N Y N N Y N N Y

Y Y Y Y Y

192.611(c) 192.611(d) 192.612 192.612(a)

N N Y N N Y

Y Y

Y Y N

36

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Notification, marking and placement Continuing surveillance. Procedure for surveillancerecondition, Program to phase out, or reduce the MAOP Damage prevention program. Implementation of written damage prevention program Written program contents Participation in one call system Identification of excavators General notification Receiving and recording notification of planned excavations Notification of type of temporary markings and how to identify Temporary marking of buried pipelines in area of excavation

192.612(b) 192.613 192.613(a) 192.613(b)

Offshore remedial action

N N Y

N N Y N N Y

Y Y Y

192.614 192.614(a) N N Y Y

192.614(c) 192.614(b) 192.614(c)(1) 192.614(c)(2) 192.614(c)(3)

N N Y N N Y N N Y N N Y

Y Y Y Y

192.614(c)(4)

N N Y

192.614(b)(5)

Locate pipe

Y Y Y

Y Y

37

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Inspection for damage Leak survey Damage prevention program not required Pipelines operated by persons other than municipalities Emergency plans. Written procedures Receiving, identifying and classifying notices of events Establishing and maintaining communication Prompt and effective response to a notice Availability of personnel, equipment, tools, and materials Protecting people first and then property Emergency shutdown and pressure reduction

192.614(b)(6)(i Inspect third party ) excavation 192.614(b)(6)(ii Leak survey ) 192.614(d) 192.614(e)

Y Y Y Y Y Y N N Y N N Y

Y Y Y Y N N

Y Y

192.615 192.615(a) 192.615(a)(1)

N N Y

192.615(a)(2)

N N Y

192.615(a)(3) 192.615(a)(4)

Response to a notice of emergency

Y Y Y N N Y

Y Y Y

192.615(a)(5) 192.615(a)(6) Pressure control

Y Y Y Y Y Y

N Y Y Y

38

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Making safe any actual or potential hazard Notification and coordination with public safety officials Safely restoring any service outage Action under 192.617 Furnish procedures, training and review of emergency response Liaison with public officials Public education. Investigation of failures. MAOP: steel or plastic pipelines. MAOP Over-pressure protective devices Highest actual operating pressure MAOP: high pressure distribution systems MAOP Over-pressure protective devices

192.615(a)(7) 192.615(a)(8)

N N Y Y N Y

N N

192.615(a)(9) 192.615(a)(10) 192.615(b)

Service restoration

Y Y Y N N Y N N Y

Y Y N Y

192.615(c) 192.616 192.617 192.619 192.619(a) 192.619(b) 192.619(c) 192.621 192.621(a) 192.621(b) Pressure control Pressure control

N N Y N N Y N N Y

Y Y Y

Y Y Y N N Y Y Y Y

Y Y Y Y Y

Pressure control

Y Y Y N N Y

Y Y Y

39

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Low-pressure distribution systems. Maximum allowable operating pressure Minimum allowable operating pressure Odorization of gas. Distribution lines Transmission lines in Class 3 or Class 4 location requirements Odorant Odorant solubility Equipment for odorization Periodic sampling Tapping pipelines under pressure. Purging of pipelines.

192.623 192.623(a) 192.623(b) 192.625 192.625(a) 192.625(b) 192.625(c) 192.625(d) 192.625(e) 192.625(f) 192.627 192.629 Pressure control Pressure control Y Y Y Y Y Y Y Y Y Y

Odorization Odorization

Y Y Y Y Y Y N N N Y Y N N N Y Y Y Y Y Y Y

Y Y Y Y Y Y Y Y Y Y Y Y Y

Odorization Tapping pipelines Purging

Y Y Y Y

Y Y Y

40

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Subpart M Maintenance Scope. General. Maintenance in accordance with this Subpart Repair, replacement or removal of unsafe pipeline segments Repair, replacement or removal of unsafe pipeline segments Prompt repair of hazardous leaks Transmission lines: Patrolling Transmission lines: patrol program Patrol frequency Patrol methods Transmission lines: Leakage surveys. Line markers for mains and transmission lines.

192.701 192.703 192.703(a)

N N Y N N Y

N N

192.703(b)

Main O&M

Y Y Y

Y Y

192.703(b)

Transmission Line O&M

Y Y Y

192.703(c) 192.705 192.705(a) 192.705(b) 192.705(c) 192.706 192.707

Leak repair

Y Y Y

Y Y

Transmission Line Patrolling Transmission line patrols Leak survey Transmission Line Main O&M

Y Y Y N N Y Y Y Y Y Y Y Y Y Y

Y Y Y Y Y Y

Y Y

41

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Line markers for mains and transmission lines. Transmission lines: Record keeping. Transmission lines: General requirements for repair procedures. Transmission lines: Field repair of imperfections and damages. Transmission lines: Permanent field repair of welds. Transmission lines: Permanent field repair of leaks. Transmission lines: Testing of repairs. Testing of replacement pipe in place Testing of replacement pipe, prior to installation Testing of repairs made by welding Testing of repairs made by welding

192.707 192.709 192.711

Transmission Line O&M

Y Y Y Y Y Y

Y N Y

Transmission Line O&M

Y Y Y

192.713

Transmission Line O&M

Y Y Y

192.715

Welding

Y Y Y

192.717

Leak repair

Y Y Y

192.719 192.719(a) 192.719(a) 192.719(b) 192.719(b) Welding - Visual inspection Welding - NDE Pressure test Y Y Y N N Y Y Y Y Y Y Y Y Y Y Y Y Y

42

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Distribution system: Patrolling. Patrol frequency Patrolling Anticipated movement patrolling Distribution system: Leakage surveys. Provision for periodic leakage surveys Business district leakage surveys Leakage surveys outside business districts Test requirements for reinstating service lines Testing of disconnected service lines before reinstatement Testing of temporarily disconnected services lines before reinstatement or Abandonment deactivation of facilities.

192.721 192.721(a) 192.721(a) 192.721(b ) 192.723 192.723(a) 192.723(b)(1) 192.723(b)(2) 192.725 192.725(a) Pressure test Service lines Y Y Y Y Y Leak survey Leak survey Distribution Leak survey Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Distribution system: Patrolling Distribution system: Patrolling Distribution system: Patrolling N N Y Y Y Y Y Y Y Y Y Y Y Y Y

192.725(b)

Pressure test

Y Y Y

Y Y

192.727

43

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Abandonment or discontinuance in accordance with this section Abandonment in place Abandonment in place Abandonment in place

192.727(a)

N N Y

192.727(b) 192.727(b) 192.727(b)

Inactive pipelines, except 192.727(c) service lines Inactive pipelines, except 192.727(c) service lines Service discontinuance 192.727(d) Purging with air Abandoned vaults Compressor stations: Inspection and testing of relief devices. Inspection and testing of pressure-relieving devicesor replacement of Repair defective or inadequate equipment 192.727(e) 192.727(f) 192.731

Transmission line O&M Abandonment in place Service line O&M Abandonment in place Main O&M Abandonment in place Main O&M Inactivation of main Transmission line O&M Inactivation of transmission line Service line O&M Service discontinuance Purging

Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y

Y Y Y Y Y Y Y Y Y Y Y Y N

192.731(a) 192.731(b)

Pressure control device maintenance Pressure control device maintenance

Y Y Y Y Y Y

Y Y

Y Y

44

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Inspection and testing of 192.731(c) remote control shutdown devices Compressor stations: 192.735 storage of combustible material. Limits on quantity of 192.735(a) flammable and combustible material stored Above ground oil and gasoline storage Compressor buildings: Gas detection. Requirement for fixed gas detection and alarm system Continuous monitoring and warning Gas detection system maintenance and performance test Pressure limiting and regulating stations: Inspection and testing. 192.735(b) 192.736 192.736(a)

Pressure control device maintenance

Y Y Y

N N Y

N N Y

Y N Y

192.736(b) 192.736(c) Maintain gas detection system Pressure control device maintenance

Y N Y Y Y Y

Y Y Y

192.739

Y Y Y

Y Y

45

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Telemetry or recording gauges. Distribution system more than one district pressure regulating station Distribution system single district pressure regulating station Abnormally high or low pressure Testing of relief devices Testing in place, if feasible Testing not feasible Insufficient capacity of relieving device Valve maintenance: Transmission lines. Valve maintenance: Distribution systems. Vault maintenance. Inspection Inspection of equipment if gas found Ventilation equipment inspection

192.741 192.741(a) N N Y Y

192.741(b)

N N Y

192.741(c) 192.743 192.743(a) 192.743(b) 192.743(c) 192.745 192.747 192.749 192.749(a) 192.749(b) 192.749(c)

Pressure control device maintenance Pressure control device maintenance Pressure control device maintenance Valve maintenance transmission Valve maintenance distribution Vault maintenance Pressure control device maintenance Vault maintenance

Y Y Y

Y Y

Y Y Y N N Y Y Y Y Y Y Y Y Y Y

Y Y Y Y Y Y Y Y

Only if gauge or telemeter

Y Y

Y Y Y Y Y Y Y Y Y

Y Y Y Y Y Y

Y Y Y

46

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

Vault cover inspection Prevention of accidental ignition. Steps to minimize accidental ignition of gas Gas vented into open air Gas or electric welding and cutting Warning signs Caulked bell and spigot joints. Sealing when pressure is more than 25 p.s.i.g. Sealing of exposed joints subject to pressure of 25 p.s.i.g. or less Protecting cast-iron pipelines. Protection during disturbance Permanent protection for disturbed segment

192.749(d) 192.751 192.751 192.751(a) 192.751(b) 192.751(c) 192.753 192.753(a) 192.753(b) Joining cast iron pipe Joining cast iron pipe Prevention of accidental Split Mains, ignition. Service, Trans Purging Welding Prevention of accidental Split Mains, ignition. Service, Trans

Y Y Y

Y Y Y Y Y Y Y Y Y Y Y Y

Y Y Y Y Y Y Y Y

Y Y Y Y

Y Y Y Y Y Y

Y Y Y Y

192.755 192.755(a) 192.755(b) Support of cast iron pipe Support of cast iron pipe Y Y Y Y Y Y Y Y Y Y Y Y

47

8/13/2012

Energy Training Network

Operator Qualification Potential Covered Tasks


Four Part Test On Pipeline Facility Perform on system Req by 49CFR192 Affects Op or Integ

Draft

Title/Description

49CFR192 Rule

Covered Task

Subtask

O&M Task

LDC Tran

Notes

48

8/13/2012

Das könnte Ihnen auch gefallen